26C2024005 Renovate Armory Montague Addendum 1.pdf
PDF 1 MB Posted
- Solicitation number
- RFQ 171 230000000592 3
- Issued by
- Oakland County, Michigan Center CDP, Michigan
About this file
This is Addendum No. 1 to a construction project issued by the State of Michigan Department of Military and Veterans Affairs for the renovation of the Armory in Montague, Michigan (Project 26C2024005). The addendum, dated July 19, 2023, modifies and clarifies the original bid documents and was issued to all bidders prior to the bid opening scheduled for July 26, 2023, at 2:00 PM. Key modifications include the addition of 1,000 square feet of roof ballast material removal, expansion of work scope to include Corridor 123 with floor grinding/polishing, new base installation, and wall/ceiling/door painting, and the removal of an ANSUL SPA-50 dry chemical fire suppression system from rooms 103 and 125. The addendum also incorporates four new specification sections for aluminum windows, metal lockers, portable dock equipment, and horizontal louver blinds, along with updated drawing references and clarifications regarding contractor responsibilities for testing, masonry wall removal and restoration in specific rooms, guardrail specifications, and culvert installation details. A pre-bid walk-through meeting was conducted on July 11, 2023, with notes provided as part of the addendum package.
The addendum includes detailed technical specifications for all added products and materials, including aluminum window performance standards (AAMA/WDMA/CSA 101/I.S.2/A440, AW-150 minimum), metal lockers with knocked-down construction from manufacturers such as Republic Storage Systems or Lyon Workspace Products, portable dock equipment with a minimum 100,000-pound lifting capacity, and horizontal louver blinds with 1-inch aluminum slats. Manufacturers of record are listed as basis-of-design products with approved alternatives specified. Warranty periods are established at ten years for windows and glazing from the date of substantial completion, with a three-year contractor installation warranty. The specifications mandate that all testing be the contractor's responsibility, clarify that existing underground fuel storage tanks are steel, and permit contractors to use their own waste management forms rather than those provided. Soil boring information for the site is referenced and attached to the addendum for bidder reference.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FORM BF-1
State of Michigan DATE ISSUED: July 19, 2023 Department of Military and Veterans Affairs INDEX CODE NO: 1530 Construction & Facilities Office Project: 26C2024005 Reserve Forces Service Center State Unit: Dept. of Military and 3423 N. Martin Luther King Blvd. Rm. 321 Veterans Affairs Lansing, Michigan 48906-2934
FILE NO: 511/23322.AGY
SUBJECT: Renovate Armory Montague Armory Montague, MI BID OPENING: July 26, 2023 - 2:00PM
ADDENDUM NO. 1
TO: All Bidders
SUBJECT: This Addendum is issued to revise and clarify the following:
1. Please see the file “Pre-Bid Walk-Thru meeting notes dated July 11, 2023” that was submitted previously for questions answered on site that are part of this Addendum.
2. Add the removal of 1000 sq. ft. of roof ballast material (stone) that is located southwest of the armory and southeast of the cold storage building on the ground. This should be removed off site.
3. Add Corridor 123 to the project work. This work is similar to 113, 114, 124. Grind/polish floor, new base, paint walls/ceiling and doors/frames both sides.
4. Specifications: Add specification section “085113 Aluminum Window 24005 Addendum 1”, this is attached.
5. Specifications: Add specification section “105113 Metal Lockers 24005 Addendum 1”, this is attached.
6. Specifications: Add specification section “111323 Portable Dock Equipment 24005 Addendum 1”, this is attached.
7. Specifications: Add specification section “122113 Horizontal Louver Blinds 24005 Addendum 1”, this is attached.
8. Specifications: Refer to section 321216 Asphalt Paving, Part 2.1, B, the binder can be PG 58-28 in lieu of
PG 58-22.
9. Clarification: Provide all new lockers and benches.
10. Clarification: Provide horizontal louver blinds for new windows.
11. Clarification: The contractor is responsible for all testing.
12. Clarification: The existing underground fuel storage tanks are steel.
13. Clarification: The contractor can use their own waste management forms instead of the ones provided.
14. Clarification: Add the demo and removal of the ANSUL SPA-50 Pre-Engineered dry chemical agent fire suppression system in the supply room (room 103 and 125) including all piping, electrical, and related components. Repair and paint any penetrations left from the removal of the system.
15. Clarification: The original soil borings for the site are available, “Montague Armory Soil Borings Addendum 1”, this is attached.
16. Clarification: Remove masonry wall, ceiling, and sawcut/remove concrete floor as needed to remove and install new plumbing/fixtures and mechanical in rooms 111, 112, and 135. Infill, patch, replace/match, and install new wall/ceiling/floor.
17. Clarification: Use MDOT guardrail type A.
18. Drawings: Refer to Drawing C2, Gravel area should be referenced as Detail C, sheet C5.
19. Drawings: Refer to Drawing C2, use a 12” CMP culvert under the entrance from Industrial Park Drive as shown.
20. Drawings: Refer to Drawing A915, Sheet has been updated to include window details. New drawing
“26C2024005 Renovate Armory Montague A915 Addendum 1” is attached.
21. Drawings: Refer to Drawing E107, The Fire Alarm Plan scale should be 1/8” = 1’ in lieu of 1/16” = 1’.
22. Drawings: Refer to Drawing E010, there are 9 Type A fixtures, pole mounted, two are dual head. There are 4 type B fixtures wall mounted.
ACKNOWLEDGEMENT: A copy of this Addendum, properly signed in the space provided below, shall be returned with the Bidder's proposal.
FIRM NAME
Kurt Maiberger Project Manager BIDDER'S SIGNATURE Construction & Facilities Management Office
ALUMINUM WINDOWS 085113 - 1
SECTION 085113 - ALUMINUM WINDOWS
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes aluminum windows for exterior locations.
1.2 SUBMITTALS
A. Product Data: For each type of product.
B. Shop Drawings: Include plans, elevations, sections, hardware, accessories, operational clearances, and details of installation, including anchor, flashing, and sealant installation.
C. Samples: For each exposed product and for each color specified.
D. Product Schedule: For aluminum windows. Use same designations indicated on Drawings.
E. Product test reports.
F. Sample warranties.
1.3 WARRANTY
A. Manufacturer's Warranty: Manufacturer agrees to repair or replace aluminum windows that fail in materials or workmanship within specified warranty period.
1. Failures include, but are not limited to, the following:
a. Failure to meet performance requirements.
b. Structural failures including excessive deflection, water leakage, condensation, and air infiltration.
c. Faulty operation of movable sash and hardware.
d. Deterioration of materials and finishes beyond normal weathering.
e. Failure of insulating glass.
2. Warranty Period:
a. Window: 10 years from date of Substantial Completion.
b. Glazing Units: 10 years from date of Substantial Completion.
c. Aluminum Finish: 10 years from date of Substantial Completion.
B. Contractor’s Warranty: Contractor agrees to repair or replace aluminum windows that fail in installation workmanship within specified warranty period.
1. Warranty Period:
a. 3 years from date of Substantial Completion.
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Basis-of-Design Product: Subject to compliance with requirements, provide EFCO Corporation, FX32 Thermal, AW150, 3-1/4" frame depth, inside glazed, Fixed windows or a comparable product by one of the following:
ALUMINUM WINDOWS 085113 - 2
1. EFCO Corporation; a Pella company.
2. Gerkin Windows and Doors.
3. Kawneer North America; an Alcoa company.
4. TRACO.
5. Wausau Window and Wall Systems.
2.2 WINDOW PERFORMANCE REQUIREMENTS
A. Product Standard: AAMA/WDMA/CSA 101/I.S.2/A440.
1. Minimum Performance Class: AW-150.
2.3 ALUMINUM WINDOWS
A. Operating Types: As indicated on Drawings.
B. Frames and Sashes: Thermally broken aluminum extrusions complying with
AAMA/WDMA/CSA 101/I.S.2/A440.
C. Insulating-Glass Units: ASTM E 2190.
1. Glass: ASTM C 1036, Type 1, Class 1, q3.
a. Tint: Clear.
b. Double pane insulated high-performance glass of 1" total thickness.
c. Exterior Board - 3/16" thick, heat strengthened, clear.
d. Interior Board - 3/16" thick, annealed, clear.
e. Low-E coating shall be applied to surface #3 equal to PPG Solarban 60.
D. Glazing System: Manufacturer's standard factory-glazing system that produces weathertight seal.
E. Hardware, General: Manufacturer's standard corrosion-resistant hardware sized to accommodate sash weight and dimensions.
1. Exposed Hardware Color and Finish: As selected by Design Professional from manufacturer's full range.
F. Weather Stripping: Provide full-perimeter weather stripping for each operable sash unless otherwise indicated.
G. Fasteners: Noncorrosive and compatible with window members, trim, hardware, anchors, and other components.
1. Exposed Fasteners: Do not use exposed fasteners to the greatest extent possible. For application of hardware, use fasteners that match finish hardware being fastened.
2.4 ACCESSORIES
A. Interior Trim: Extruded-aluminum profiles in sizes and configurations indicated on Drawings.
B. Panning Trim: Extruded-aluminum profiles in sizes and configurations indicated on Drawings.
C. Receptor System: Two-piece, snap-together, thermally broken, extruded-aluminum receptor system that anchors windows in place.
ALUMINUM WINDOWS 085113 - 3
2.5 FABRICATION
A. Fabricate aluminum windows in sizes indicated. Include a complete system for assembling components and anchoring windows.
B. Glaze aluminum windows in the factory.
C. Provide weep holes and internal passages to conduct infiltrating water to exterior.
D. Provide water-shed members above side-hinged sashes and similar lines of natural water penetration.
E. Provide cover plates, matching window units, complete with anchors for support to structure and installation of window units. Allow for erection tolerances and provide for movement of window units due to thermal expansion and building deflections, as indicated. Provide cover plates capable of withstanding design wind loads of window units.
F. Complete fabrication, assembly, finishing, hardware application, and other work in the factory to greatest extent possible. Disassemble components only as necessary for shipment and installation.
2.6 ALUMINUM FINISHES
A. Anodic Finish: Class I complying with AAMA 611.
1. Color: Dark bronze.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Comply with manufacturer's written instructions for installing windows, hardware, accessories, and other components. For installation procedures and requirements not addressed in manufacturer's written instructions, comply with installation requirements in ASTM E 2112.
B. Install windows level, plumb, square, true to line, without distortion or impeding thermal movement, anchored securely in place to structural support, and in proper relation to wall flashing and other adjacent construction to produce weathertight construction.
C. Install windows and components to drain condensation, water penetrating joints, and moisture migrating within windows to the exterior.
D. Separate aluminum and other corrodible surfaces from sources of corrosion or electrolytic action at points of contact with other materials.
E. Adjust operating sashes and hardware for a tight fit at contact points and weather stripping for smooth operation and weathertight closure.
F. Clean exposed surfaces immediately after installing windows. Avoid damaging protective coatings and finishes. Remove excess sealants, glazing materials, dirt, and other substances.
G. Remove and replace glass that has been broken, chipped, cracked, abraded, or damaged during construction period.
ALUMINUM WINDOWS 085113 - 4
END OF SECTION 085113
METAL LOCKERS 105113 - 1
SECTION 105113 – METAL LOCKERS
PART ONE GENERAL
1.01 DESCRIPTION
A. Provide metal lockers indicated.
1. Standard metal lockers.
2. Benches.
1.02 SUBMITTALS
A. Product Data- Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for each type of metal locker.
B. Shop Drawings – Include plans, elevations, sections, details, and attachments to other work.
1. Show base, sloping tops, filler panels, recess trim, and other accessories.
2. Include locker identification system.
C. Qualification Data – For Installer.
D. Maintenance Data – For adjusting, repairing, and replacing locker doors and latching mechanisms.
E. Warranty – Special warranty specified in this Section.
1.03 QUALITY ASSURANCE
A. Installer Qualifications – An authorized representative of metal locker manufacturer for installation and maintenance of units required for this Project.
B. Source Limitations – Obtain metal lockers and accessories through one source from a single manufacturer.
C. Product Options – Drawings indicate size, profiles, and dimensional requirements of metal lockers and are based on the specific system indicated. See INSTRUCTIONS TO BIDDERS paragraph “Substitutions”.
1. Do not modify intended aesthetic effects, except with DMVA’s approval. If modifications are proposed, submit comprehensive explanatory data to DMVA Designer for review.
1.04 DELIVERY, STORAGE, AND HANDLING
A. Do not deliver metal lockers until spaces to receive them are clean, dry, and ready for metal locker installation.
1.05 PROJECT CONDITIONS
A. Field Measurements – Verify the following by field measurements before fabrication and indicate measurements on Shop Drawings:
1. Concealed framing, blocking, and reinforcements that support metal lockers before they are enclosed.
2. Recessed openings.
3. Established Dimensions – Where field measurements cannot be made without delaying the Work, establish recessed opening dimensions and proceed with fabricating metal lockers without field
METAL LOCKERS 105113 - 2
measurements. Coordinate wall and floor construction to ensure that actual recessed opening dimensions correspond to established dimensions.
1.06 COORDINATION
A. Coordinate size and location of concrete bases for metal lockers.
B. Coordinate sizes and locations of framing, blocking, furring, reinforcements, and other related units of
Work specified in other Sections to ensure that metal lockers can be supported and installed as indicated.
1.07 WARRANTY
A. Special Warranty – Manufacturer’s standard form in which manufacturer agrees to repair or replace components of metal lockers that fail in materials or workmanship, excluding finish, within specified warranty period.
1. Failures include, but are not limited to, the following:
a. Structural failures.
b. Faulty operation of latches and other door hardware.
2. Damage from deliberate destruction and vandalism is excluded.
3. Warranty Period for Knocked-Down Metal Lockers – Two years from date of Acceptance.
PART TWO - PRODUCTS
2.01 MATERIALS
A. Cold-rolled Steel Sheet – ASTM A 1008, Commercial Steel (CS) Type B, suitable for exposed applications.
B. Expanded Metal – ASTM F 1267, Type II (flattened), Class I, ¾” steel mesh, with at least 70% open area.
C. Fasteners – Zinc- or nickel-plated steel, slotless-type exposed bolt heads, and self-locking nuts or lock washers for nuts on moving parts.
D. Anchors – Select material, type, size, and finish required for secure anchorage to each substrate.
1. Provide nonferrous-metal or hot-dip galvanized anchors and inserts on inside face of exterior walls and elsewhere as required for corrosion resistance.
2. Provide toothed-steel or lead expansion sleeves for drilled-in-place anchors.
2.02 KNOCKED-DOWN STANDARD METAL LOCKERS
A. Basis-of-Design Product – Republic Storage System Company; Lockers or a comparable product of one of the following:
B. Available Products:
1. Lyon Workspace Products; Standard Lockers.
2. Penco Products Inc., subsidiary of Vesper Corp.
3. Republic Storage Systems Company; Standard Lockers.
C. Locker Arrangement – Single tier, 12”w x 18”d x 72” h, As indicated on Drawings.
D. Body – Assembled by riveting or bolting body components together. Fabricate from unperforated, cold-rolled steel sheet with thickness as follows:
1. Tops, Bottoms, and Intermediate Dividers – 0.0209”, with single bend at sides.
2. Backs and Sides – 0.0209” thick, with full-height, double-flanged connections.
METAL LOCKERS 105113 - 3
3. Shelves – 0.0209” thick, with double bend at front and single bend at sides and back.
E. Frames – Channel formed; fabricated from 0.0528” thick, cold-rolled steel sheet; lapped and factory welded at corners; with top and bottom main frames factory welded into vertical main frames. Form continuous, integral door strike full height on vertical main frames.
1. Cross Frames between Tiers – Channel formed and fabricated from same material as main frames;
welded to vertical frame members.
F. Doors – One-piece; fabricated from 0.0528” thick, cold-rolled steel sheet; formed into channel shape with double bend at vertical edges, and with right-angle single bend at horizontal edges.
1. Reinforcement – Manufacturer’s standard reinforcing angles, channels, or stiffeners for doors more than 15” wide; welded to inner face of doors.
2. Stiffeners – Manufacturer’s standard full-height stiffener fabricated from 0.0428” thick, cold-rolled steel sheet; welded to inner face of doors.
3. Door Style – Vented panel; louvered vents, not less than three louver openings at top and bottom for double-tier lockers.
4. Knuckle Hinges: Steel, full loop, five or seven knuckles, tight pin; minimum 2 inches high.
G. Projecting Door Handle and Latch – Manufacturer’s standard, finger-lift latch control designed for use with padlocks; positive automatic, prelocking, pry resistant; chromium-plated, vandal-resistant, lift-up handle.
1. Latch Hooks – Equip door 48” and high with 3 latch hooks and door less than 48” with 2 latch hooks;
fabricated from minimum 0.0966” thick steel; welded or riveted to full-height door strikes; with resilient silencer on each latch hook.
2. Latching Mechanism – Manufacturer’s standard rattle-free latching mechanism and moving components isolated to prevent metal-to-metal contact, and incorporating a prelocking device that allows locker door to be locked while door is open and then closed without unlocking or damaging lock or latching mechanism.
H. Equipment – Equip each metal locker with identification plate and the following, unless otherwise indicated:
1. Double Tier Units – One double-prong ceiling hook, and three single-prong wall hooks.
I. Accessories
1. Continuous Base – Fabricated from cold-rolled steel sheet, manufacturer’s standard thickness, but not less than 0.0528” thick.
a. Height – 4”.
2. Individual Sloping tops – Fabricated from cold-rolled steel sheet, manufacturer’s standard thickness, but not less than 0.0329” thick.
a. Closures – Vertical-end type.
b. Sloped top corner fillers, mitered.
3. Filler Panels – Fabricated from cold-rolled steel sheet, manufacturer’s standard thickness, but not less than 0.0329” thick.
4. Finished End Panels – Fabricated from 0.0209” thick, cold-rolled steel sheet.
J. Finish – Baked enamel or powder coat.
1. Color – As selected by DMVA from manufacturer’s full range.
2.03 LOCKER BENCHES
A. General – Provide locker benches fabricated by same manufacturer as metal lockers.
B. Bench Tops – Manufacturer’s standard 1-piece units, of the following material, minimum 12” wide by 1 ¼” thick, with rounded corners and edges.
METAL LOCKERS 105113 - 4
1. Laminated clear hardwood with one coat of clear sealer on all surfaces, and one coat of clear lacquer on top and sides.
C. Fixed Pedestals: Manufacturer's standard tubular steel supports, with predrilled fastener holes for attaching bench top and anchoring to floor, complete with fasteners and anchors. Provide pedestals as detailed on DRAWINGS.
1. Color: As selected by DMVA from manufacturer's full range.
2.04 FABRICATION
A. General – Fabricate metal lockers square, rigid, and without warp; with metal faces flat and free of dents or distortion. Make exposed metal edges free of sharp edges and burrs, and safe to touch.
1. Form body panels, doors, shelves, and accessories from one-piece steel sheet, unless otherwise indicated.
2. Provide fasteners, filler plates, supports, clips, and closures as required for a complete installation.
B. Unit Principle – Fabricate each metal locker with an individual door and frame; individual top, bottom, and back; and common intermediate uprights separating compartments.
C. Knocked-Down Construction – Fabricate metal lockers for nominal assembly at Project site using nuts, bolts, screws, or rivets. Factory weld frame members together to form a rigid, one piece assembly.
D. Hooks – Manufacturer’s standard ball-pointed, aluminum or steel; zinc plated.
E. Identification Plates – Manufacturer’s standard etched, embossed, or stamped aluminum or plastic plates;
with numbers and letters at least 3/8” high.
F. Legs – Formed by extending vertical frame members or by attaching gusset-type legs to locker body; with provision for fastening to floor; finished to match lockers.
1. Closed front and end bases – Fabricate bases without overlap or exposed fasteners; finished to match lockers.
G. Continuous Base – Formed into channel or Z profile for stiffness, and fabricated in lengths as long as practicable to enclose base and base ends of metal lockers; finished to match lockers.
H. Continuous Sloping Tops – Fabricated in lengths as long as practicable, without visible fasteners at splice locations; finished to match lockers.
1. Sloped top corner fillers, mitered.
I. Filler Panels – Fabricated in an unequal leg angle shape; finished to match lockers. Provide slip joint filler angle formed to receive filler panel.
J. Finished End Panels – Designed for concealing unused penetrations and fasteners, except for perimeter fasteners, at exposed ends of nonrecessed metal lockers; finished to match lockers.
1. Provide one-piece panels for double-row (back-to-back) locker ends.
2.05 STEEL SHEET FINISHES
A. General – Comply with NAAMM’s “Metal Finishes Manual for Architectural and Metal Products” for recommendations for applying and designating finishes.
B. Factory finish steel surfaces and accessories except stainless-steel and chrome-plated surfaces.
METAL LOCKERS 105113 - 5
C. Surface Preparation – Clean surfaces of dirt, oil, grease, mill scale, rust, and other contaminants that could impair paint bond. Use manufacturer’s standard methods.
D. Baked-Enamel Finish – Immediately after cleaning, pretreating, and phosphatizing, apply manufacturer’s standard thermosetting baked-enamel finish. Comply with paint manufacturer’s written instructions for application, baking, and minimum dry film thickness.
E. Powder-Coat Finish – Immediately after cleaning and pretreating, electrostatically apply manufacturer’s standard baked-polymer thermosetting powder finish. Comply with resin manufacturer’s written instructions for application, baking, and minimum dry film thickness.
PART THREE - EXECUTION
3.01 EXAMINATION
A. Examine walls, floors, and support bases, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of work.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
3.02 INSTALLATION
A. General – Install level, plumb, and true; shim as required, using concealed shims.
1. Anchor locker runs at ends and at intervals recommended by manufacturer, but not more than 36” o.c.
Install anchors through backup reinforcing plates, channels, or blocking as required to prevent metal distortion, using concealed fasteners.
2. Anchor single rows of metal lockers to walls near top and bottom of lockers or top of lockers and to floor.
3. Anchor back-to-back metal lockers to floor.
B. Knocked-Down Metal Lockers – Assemble knocked-down metal lockers with standard fasteners, with no exposed fasteners on door faces or face frames.
C. All-Welded metal Lockers – Connect groups of all-welded metal lockers together with standard fasteners, with no exposed fasteners on face frames.
D. Equipment and Accessories – Fit exposed connections of trim, fillers, and closures accurately together to form tight, hairline joints, with concealed fasteners and splice plates.
1. Attach hooks with at least two fasteners.
2. Attach door locks on doors using security fasteners.
3. Identification Plates – Identify metal lockers with identification indicated on Drawings.
a. Attach plates to each locker door, near top, centered, with at least two aluminum rivets.
4. Attach recess trim to recessed metal lockers with concealed clips.
5. Attach filler panels with concealed fasteners. Locate filler panels where indicated on Drawings.
6. Attach sloping top units to metal lockers, with closures at exposed ends.
7. Attach finished end panels with fasteners only at perimeter to conceal exposed ends of nonrecessed metal lockers.
E. Fixed Locker Benches – Provide not less than 2 supports for each bench, uniformly spaced not more than
24” apart. Provide Blocking in walls for wall hung supports.
3.03 CLEANING
A. Clean, lubricate, and adjust hardware. Adjust doors and latches to operate easily without binding.
METAL LOCKERS 105113 - 6
B. Protect metal lockers from damage, abuse, dust, dirt, stain, or paint. Do not permit metal locker use during construction.
C. Touch up marred finishes, or replace metal lockers that cannot be restored to factory-finished appearance.
Use only material and procedures recommended or furnished by metal locker manufacturer.
END OF SECTION 105113
PORTABLE DOCK EQUIPMENT 111323 - 1
SECTION 111323 - PORTABLE DOCK EQUIPMENT
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes portable loading docks.
1.2 SUBMITTALS
A. Product Data: For each type of product.
1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes.
2. Include rated capacities, operating characteristics, electrical characteristics, and furnished specialties and accessories.
B. Shop Drawings: For portable dock equipment.
1. Include plans, elevations, sections, and attachment details.
2. Include details of equipment assemblies. Indicate dimensions, weights, loads, required clearances, method of field assembly, components, and location of each field connection.
3. Include diagrams for power, signal, and control wiring.
C. Operation and Maintenance Data: For portable dock equipment, to include in operation and maintenance manuals.
PART 2 - PRODUCTS
2.1 PORTABLE EQUIPMENT RAMP
A. Basis-of-Design is a Yard King Steel Equipment Ramp or an approved equal.
B. Rated Capacity: Lifting capacity of not less than 100,000 lbs.
C. Platform: 2 ½” Heavy serrated steel grating deck plate.
1. Overall size: 8’-4” wide by 45’ long.
a. Ramp Size: 8’-4” wide by 25’ long.
b. Level-Off Platform Size: 8’-4” wide by 20’ long including a 30” opening in center along entire length.
2. Platform/Ramp Safety Curb: 5 ¾” high along entire length, both sides.
3. Steel Height Adjusting Plates.
a. Manufacturer’s standard.
D. Legs: Steel height adjusting with manual crank.
1. Height adjustment: 3’-6” to 4’-8”.
E. Construction: Fabricate lift from structural-steel shapes rigidly welded and reinforced for maximum strength, safety, and stability. Design assembly to withstand deformation during both operating and stored phases of service. Provide mounting brackets and removable lifting eyes for ease of installation.
F. Materials:
PORTABLE DOCK EQUIPMENT 111323 - 2
1. Steel Plates, Shapes, and Bars: ASTM 36/A 36M.
2. Rolled-Steel Floor Plate: ASTM A 786/A 786M, rolled from steel plate complying with
ASTM A 572/A 572M, Grade 55.
3. Steel Tubing: ASTM A 500/A 500M, cold formed.
2.2 FINISH REQUIREMENTS
A. Baked-on Factory Finish: Provide unless otherwise indicated. Clean, pretreat, and apply manufacturer's standard two-coat, baked-on finish consisting of prime coat and thermosetting topcoat
1. Color: Safety Yellow, RAL 1003.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine areas and conditions, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of the Work.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 INSTALLATION, GENERAL
A. Install portable dock equipment as required for a complete installation.
3.3 ADJUSTING
A. Adjust portable dock equipment to function smoothly and safely, and lubricate as recommended by manufacturer.
B. Test lifts for vertical travel and adjust to maintain operating range indicated.
C. After completing installation of exposed, factory-finished portable dock equipment, inspect exposed finishes and repair damaged finishes.
END OF SECTION 111323
HORIZONTAL LOUVER BLINDS 122113 - 1
SECTION 122113 - HORIZONTAL LOUVER BLINDS
PART ONE GENERAL
1.01 SUMMARY
A. Provide blinds with aluminum louver 1” wide slats for all new window openings.
1.02 SUBMITTALS
A. Product Data – For each type of product indicated. Include styles, material descriptions, construction details, dimensions of individual components and profiles, features, finishes, and operating.
PART TWO PRODUCTS
2.01 MANUFACTURERS
A. Available Manufacturers include, but are not limited to, the following:
1. Comfortex Window Fashions.
2. Hunter Douglas window Fashions.
3. Levolor Contract; a Newell Company; Levolor.
4. Springs Window Fashions Division, Inc.
5. Verosol USA, Inc.
2.02 HORIZONTAL LOUVER BLINDS, ALUMINUM LOUVER SLATS
A. Louver Slats – Aluminum, alloy and temper recommended by producer for type of use and finish indicated; with crowned profile and radiused corners.
1. Nominal Slat Width – 1 inch.
2. Thickness – not less than .008 inches.
3. Spacing – Manufacturer’s standard.
4. Color – DMVA to choose from manufacturer’s full range.
5. Ionized Coating – Antistatic, dust-repellent, baked polyester finish.
B. Headrail – Formed steel or extruded aluminum; long edges returned or rolled; fully enclosing operating mechanisms on three sides and ends; capacity for one blind per headrail.
1. Finish Color Characteristics – Match color, texture, pattern and gloss of louver slats.
C. Bottom Rail – Formed-steel or extruded-aluminum tube, sealed with plastic or metal capped ends, bottom contoured for minimizing light gaps; with enclosed and protected ladders and tapes to prevent their contact with sill.
D. Maximum Light Blocking Blinds – Designed for eliminating all visible light gaps if slats are tilted closed;
with tight tape spacing indicated and slats with minimal-sized rout holes for ladders hidden and placed near back edge for maximum slat overlap; with headrail and bottom rail extended and formed for light-tight joints between rail and adjacent slats or construction.
E. Tilt Control – Consisting of enclosed worm gear mechanism, slip clutch or detachable wand preventing overrotation, and linkage rod, for the following operation.
1. Tilt Operation – Manual with clear plastic wand or cord-operated tilter.
2. Length of Tilt Control – Full length of blind.
3. Tilt – Full.
HORIZONTAL LOUVER BLINDS 122113 - 2
F. Lift Operation – Manual, cord lock; locks pull cord to stop blind at any position in ascending or descending travel.
G. Tilt-control and Cord-Lock Position – Right side and left side of headrail, respectively.
H. Ladders – Evenly spaced to prevent long-term louver sag.
I. Mounting Brackets: With spacers and shims required for blind placement and alignment indicated.
1. Type: Wall.
2. Intermediate Support: Provide intermediate support brackets to produce support spacing recommended by blind manufacturer for weight and size of blind.
J. Hold-Down Brackets and Hooks or Pins: Manufacturer's standard.
K. Mounting - Permitting easy removal and replacement without damaging blind or adjacent surfaces and finishes; with spacers and shims required for blind placement and alignment.
1. Provide intermediate support brackets if end support spacing exceeds spacing recommended by manufacturer for weight and size of blind.
2.03 HORIZONTAL LOUVER BLINDS FABRICATION
A. Product Standard and Description – Comply with AWCMA document 1029, unless otherwise indicated, for each horizontal louver blind designed to be self-leveling and consisting of louver slats, rails, ladders, tapes, lifting and tilting mechanisms, cord, cord lock, tilt control, and installation hardware.
B. Concealed Components – Noncorrodible or corrosion-resistant-coated materials.
1. Lifting and Tilting Mechanisms – With permanently lubricated moving parts.
C. Unit Sizes – Obtain units fabricated in sizes to fill window openings.
1. Blind Units Installed between Jambs – Width equal to ¼” per side or ½” total, plus or minus 1/8”, less than jamb-to-jamb dimension of opening in which each blind is installed. Length equal to ¼”, plus or minus 1/8”, less than head-to-sill dimension of opening in which each blind is installed.
D. Installation Brackets – Designed for easy removal and reinstallation of blind, for supporting headrail and operating hardware, and for hardware position and blind mounting method indicated.
E. Installation Fasteners – Not fewer than two fasteners per bracket, fabricated from metal noncorrosive to blind hardware and adjoining constructio0n; type designed for securing to supporting substrate; and supporting blinds and accessories under conditions of normal use.
F. Color-Coated Finish, Metal – For components exposed to view, apply manufacturer’s standard baked finish complying with manufacturer’s written instructions for surface preparation including pretreatment, application, baking, and minimum dry film thickness.
G. Component Color – Provide rails, cords, ladders, and exposed-to-view metal and plastic matching or coordinating with slat color.
HORIZONTAL LOUVER BLINDS 122113 - 3
PART THREE - EXECUTION
3.01 EXAMINATION
A. Examine substrates, areas, and conditions, with Installer present, for compliance with requirements for installation tolerances, operational clearances, and other conditions affecting performance. Proceed with installation only after unsatisfactory conditions have been corrected.
3.02 INSTALLATION, GENERAL
A. Install blinds level and plumb and aligned with adjacent units according to manufacturer’s written instructions and located so exterior louver edges in any position are not closer than 2” to interior face of glass, but not protruding into room interior. Install intermediate support as required to prevent deflection in head rail. Allow clearances between adjacent blinds and for operating glazed opening’s operation hardware, if any.
3.03 ADJUSTING
A. Adjust horizontal louver blinds to operate smoothly, easily, safely, and free from binding or malfunction throughout entire operational range.
3.04 CLEANING AND OPROTECTION
A. Clean blind surfaces after installation, according to manufacturer’s written instructions.
B. Replace damaged blinds that cannot be repaired, in a manner approved by DMVA, before time of Substantial Completion.
END OF SECTION 122113
25Z7
25Z7
25Z7
PR
EL
IM
IN
AR
Y
C O
N
ST
R U
C
TI
O N
FI
N
AL
R
EC
O
R D
IS
SU
ED
F
O R
IN
D
EX
C
O D
E
PR
O
JE
C
T
6C
ID
EN
TI
FI
C
AT
IO
N
N O
SH
EE
T
R
EN
O
VA
TE
A
R M
O R
Y
- M
O N
TA
G
U E
D
ES
IG
N
ED
D R
AW
N
C H
EC
KE
D
AP
PR
O
VE
D
ST
AT
E O
F M
IC
H
IG
AN
D
EP
AR
TM
EN
T
O F
TE
C
H N
O
LO
G Y, M
AN
AG
EM
EN
T
AN
D
B U
D G
ET
PR
O C
U R
EM
EN
T
AN
D R
EA
L
ES
TA
TE
S
ER
VI
C
ES
A D
M
IN
IS
TR
AT
IO
N D
ES
IG
N A
N D
C O
N
ST
R U
C
TI
O N
D
IV
IS
IO
N
AD
AM
L
AC
H
, R A, D
IR
EC
TO
R
KM
M
KM
M
BA
B
KM
M
D
EP
AR
TM
EN
T
O F
M
IL
IT
AR
Y
AN
D V
ET
ER
AN
S
AF
FA
IR
S
M O
N
TA
G U
E
AR
M O
R Y
M
O N
TA
G
U E, M
IC
H
IG
AN
D
AT
E
J
U N
M
AY
FI
N
IS
H
P
LA
N
A9
AutoCAD SHX Text
EXISTING 8" CMU
AutoCAD SHX Text
SEALANT, CONTINUOUS
AutoCAD SHX Text
(TYP. EACH SIDE)
AutoCAD SHX Text
EXISTING 8" CMU
AutoCAD SHX Text
SEALANT, CONTINUOUS
AutoCAD SHX Text
(TYP. EACH SIDE)
AutoCAD SHX Text
4'-4" MASONRY OPENING WIDTH
AutoCAD SHX Text
EXISTING BRICK
AutoCAD SHX Text
SEE LINTEL SCHEDULE
AutoCAD SHX Text
ON THIS DRAWING
AutoCAD SHX Text C
AutoCAD SHX Text
AutoCAD SHX Text A915
AutoCAD SHX Text
SCALE: 1-1/2" = 1'-0"
AutoCAD SHX Text
JAMB DETAIL
AutoCAD SHX Text
WINDOW
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text A915
AutoCAD SHX Text
SCALE: 1-1/2" = 1'-0"
AutoCAD SHX Text
HEAD DETAIL
AutoCAD SHX Text
WINDOW
AutoCAD SHX Text
EXIST. BOARD INSUL.
AutoCAD SHX Text
4'-8" MASONRY OPENING HEIGHT
AutoCAD SHX Text
EXISTING BRICK
AutoCAD SHX Text
REMOVE AND REPLACE
AutoCAD SHX Text
EXISTING BRICK AS
AutoCAD SHX Text
REQUIRED TO INSTALL
AutoCAD SHX Text
NEW LINTEL
AutoCAD SHX Text
INSTALL CMU BLOCK
AutoCAD SHX Text
FACE TO COVER LINTEL
AutoCAD SHX Text
PROVIDE (3) WEEP
AutoCAD SHX Text
HOLES IN BRICK
AutoCAD SHX Text
ABOVE LINTEL AREA
AutoCAD SHX Text
(EQUALLY SPACED)
AutoCAD SHX Text
EXIST. BOARD INSUL.
AutoCAD SHX Text
TREATED WOOD BLOCKING
AutoCAD SHX Text 4T59
AutoCAD SHX Text 4T59
AutoCAD SHX Text
EXISTING 8" CMU
AutoCAD SHX Text
SEALANT, CONTINUOUS
AutoCAD SHX Text
(TYP. EACH SIDE)
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text A915
AutoCAD SHX Text
SCALE: 1-1/2" = 1'-0"
AutoCAD SHX Text
SILL DETAIL
AutoCAD SHX Text
WINDOW
AutoCAD SHX Text
2'-8" FROM FINISH FLOOR
AutoCAD SHX Text
EXISTING BRICK
AutoCAD SHX Text
REMOVE AND REPLACE
AutoCAD SHX Text
EXISTING BRICK AS
AutoCAD SHX Text
REQUIRED TO INSTALL
AutoCAD SHX Text
PRECAST CONCRETE SILL
AutoCAD SHX Text
EXIST. BOARD INSUL.
AutoCAD SHX Text 4T59
AutoCAD SHX Text
TREATED WOOD BLOCKING
AutoCAD SHX Text
FLASHING
AutoCAD SHX Text
ALUMINUM WINDOW
AutoCAD SHX Text
ALUMINUM TRIM TO MATCH WINDOW
AutoCAD SHX Text
ALUMINUM WINDOW
AutoCAD SHX Text
ALUMINUM TRIM TO MATCH WINDOW
AutoCAD SHX Text
ALUMINUM WINDOW
AutoCAD SHX Text
ALUMINUM TRIM TO MATCH WINDOW
AutoCAD SHX Text DOOR SCHEDULE (only shows new doors)
AutoCAD SHX Text
NO.
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
DOOR
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
FINISH
AutoCAD SHX Text
DETAIL (#)
AutoCAD SHX Text
HEAD
AutoCAD SHX Text
JAMB
AutoCAD SHX Text
HARDWARE
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
THRESHOLD
AutoCAD SHX Text
GLAZING
AutoCAD SHX Text
GROUP
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
FRAME
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
LINTEL
AutoCAD SHX Text
DOOR TYPE:
AutoCAD SHX Text %%uTYPE C
AutoCAD SHX Text %%uTYPE B
AutoCAD SHX Text %%uTYPE A
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
4" VINYL
AutoCAD SHX Text
GRIND/POLISH
AutoCAD SHX Text
AutoCAD SHX Text
DRILL FLOOR
AutoCAD SHX Text
AutoCAD SHX Text
FEMALE RESTROOM
AutoCAD SHX Text
AutoCAD SHX Text
MALE RESTROOM
AutoCAD SHX Text
HEIGHT
AutoCAD SHX Text
FINISH
AutoCAD SHX Text
WEST
AutoCAD SHX Text
EAST
AutoCAD SHX Text
SOUTH
AutoCAD SHX Text
BASE
AutoCAD SHX Text
UNIT SUPPLY
AutoCAD SHX Text
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
NO.
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
WALLS
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text ROOM FINISH SCHEDULE (only shows new and/or revised conditions in rooms that are new or have modifications)
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
FINISH
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN'S LOCKER ROOM
AutoCAD SHX Text
AutoCAD SHX Text
MEN'S LOCKER ROOM
AutoCAD SHX Text
AutoCAD SHX Text
PHYSICAL TRAINIING
AutoCAD SHX Text
AutoCAD SHX Text
SUPPLY OFFICE
AutoCAD SHX Text 130A
AutoCAD SHX Text
LACTATION ROOM
AutoCAD SHX Text
AutoCAD SHX Text
HM
AutoCAD SHX Text
PAINTED
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
EPOXY PAINT
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
EPOXY PAINT
AutoCAD SHX Text
VINYL
AutoCAD SHX Text
CARPET
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text
AutoCAD SHX Text 2x2 ACT
AutoCAD SHX Text
VINYL
AutoCAD SHX Text
RUBBER
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text 9'-0"
AutoCAD SHX Text
AutoCAD SHX Text
2X2 ACT
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text
EPOXY PAINT
AutoCAD SHX Text
MR GYPSUM BOARD
AutoCAD SHX Text
NEW CEILING TO BE INSTALLED AS HIGH AS POSSIBLE.
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED GWB
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
GYPSUM BOARD
AutoCAD SHX Text
GYPSUM BOARD
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text 1-3/4"x3'-0"x7'-0"
AutoCAD SHX Text
HARDWARE GROUP:
AutoCAD SHX Text LOCALLY PAINT AND REPAIR CMU WALLS WHERE CAGING WAS REMOVED. PAINT CEILING AS NEEDED WHERE ITEMS ARE REMOVED.
AutoCAD SHX Text
PAINT AREA ABOVE CERAMIC TILE TO CEILING
AutoCAD SHX Text %%uTYPE 1
AutoCAD SHX Text %%uTYPE 2
AutoCAD SHX Text
FRAME TYPE:
AutoCAD SHX Text
%%UTYPE 3
AutoCAD SHX Text
LEVEL FLOOR BEFORE INSTALLING NEW RUBBER FLOOR.
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text
EPOXY PAINT
AutoCAD SHX Text
MR GYPSUM BOARD
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
1. SEE SPECIFICATIONS FOR DOOR HARDWARE GROUPS.
AutoCAD SHX Text
PAINTED
AutoCAD SHX Text
HM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
%%UGROUP 1:
AutoCAD SHX Text
1½ PR. HINGES
AutoCAD SHX Text
CLOSER
AutoCAD SHX Text
%%UTYPE D
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 16"x24"
AutoCAD SHX Text
LOUVERED
AutoCAD SHX Text
OPENING
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
PAINT AREA ABOVE CERAMIC TILE TO CEILING
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
EPOXY PAINTED GWB
AutoCAD SHX Text
EPOXY PAINTED CMU
AutoCAD SHX Text
EPOXY PAINTED GWB
AutoCAD SHX Text
EPOXY PAINTED CMU
AutoCAD SHX Text
ALL GYPSUM BOARD TO BE MOISTURE RESISTANT.
AutoCAD SHX Text
EPOXY PAINTED GWB
AutoCAD SHX Text
EPOXY PAINTED CMU
AutoCAD SHX Text
EPOXY PAINTED CMU
AutoCAD SHX Text
EPOXY PAINTED CMU
AutoCAD SHX Text
ALL GYPSUM BOARD TO BE MOISTURE RESISTANT.
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN'S SHOWER ROOM
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text
EPOXY PAINT
AutoCAD SHX Text
GYPSUM BOARD
AutoCAD SHX Text
ALL GYPSUM BOARD TO BE MOISTURE RESISTANT.
AutoCAD SHX Text
AutoCAD SHX Text
MEN'S SHOWER ROOM
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text
CERAMIC TILE
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text
EPOXY PAINT
AutoCAD SHX Text
GYPSUM BOARD
AutoCAD SHX Text
ALL GYPSUM BOARD TO BE MOISTURE RESISTANT.
AutoCAD SHX Text
AutoCAD SHX Text
LACTATION ROOM
AutoCAD SHX Text
VCT
AutoCAD SHX Text
VINYL
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINT
AutoCAD SHX Text
GYPSUM BOARD
AutoCAD SHX Text
LOCKSET WITH INDICATOR
AutoCAD SHX Text
SILENCER
AutoCAD SHX Text
WALL STOP
AutoCAD SHX Text
KICKPLATE
AutoCAD SHX Text
LINTEL SCHEDULE
AutoCAD SHX Text
MARK #
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
BRG. EL.
AutoCAD SHX Text L-1
AutoCAD SHX Text W8x10 + L3½x3½x1/4 + PL 1/4"x1'-3", 4'-8" LONG
AutoCAD SHX Text 7'-4"
AutoCAD SHX Text L-2
AutoCAD SHX Text W8x18 + L3½x3½x1/4 + PL 1/4"x1'-1", 4'-8" LONG
AutoCAD SHX Text 7'-4"
AutoCAD SHX Text L-3
AutoCAD SHX Text W8x18 + PL 1/4"x11", 4'-8" LONG
AutoCAD SHX Text 5'-4"
AutoCAD SHX Text L-4
AutoCAD SHX Text
(2) L3½x3½x1/4 LLV, 4'-8" LONG
AutoCAD SHX Text 7'-4"
AutoCAD SHX Text L-5
AutoCAD SHX Text W8x18 + PL 1/4"x7", 4'-8" LONG
AutoCAD SHX Text 7'-4"
AutoCAD SHX Text L-6
AutoCAD SHX Text 7'-4"
AutoCAD SHX Text W8x18 + PL 1/4"x11", 5'-2" LONG
AutoCAD SHX Text L-7
AutoCAD SHX Text 7'-4"
AutoCAD SHX Text W8x18 + PL 1/4"x11", 7'-8" LONG
AutoCAD SHX Text L-8
AutoCAD SHX Text 7'-4"
AutoCAD SHX Text W8x10 + PL 1/4"x11", 5'-2" LONG
AutoCAD SHX Text
TYPE
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text Csim.
AutoCAD SHX Text
%%UTYPE A
AutoCAD SHX Text
%%UTYPE C
AutoCAD SHX Text
%%UTYPE B
AutoCAD SHX Text
%%UTYPE E
AutoCAD SHX Text
%%UTYPE D
AutoCAD SHX Text
%%UNOTES:
AutoCAD SHX Text
1. ALL LINTELS TO BE CENTERED ON WALL
AutoCAD SHX Text
2. ALL LINTELS TO HAVE 8" BEARING AT ENDS.
AutoCAD SHX Text
3. FILL FIRST CMU CORE ADJACENT TO OPENING WITH GROUT.
AutoCAD SHX Text
4. LINTELS AT EXISTING CMU WALLS: ADDITIONAL WORK MAY NEED TO
AutoCAD SHX Text
BE PERFORMED TO "TOOTH" EXISTING CMU TO INSTALL NEW LINTELS.
AutoCAD SHX Text L-9
AutoCAD SHX Text 10'-8"
AutoCAD SHX Text
(2) L6x3½x1/4 (SLV), 8'-0" LONG
AutoCAD SHX Text Esim.
AutoCAD SHX Text L-10
AutoCAD SHX Text
(2) L3½x3½x1/4 LLV, 2'-4" LONG
AutoCAD SHX Text 10'-8"
AutoCAD SHX Text E
AutoCAD SHX Text 3½"
AutoCAD SHX Text 3½"
AutoCAD SHX Text 3½"
AutoCAD SHX Text 3½"
AutoCAD SHX Text L-11
AutoCAD SHX Text
(2) L3½x3½x1/4 LLV, 5'-4" LONG
AutoCAD SHX Text 7'-4"
AutoCAD SHX Text E
AutoCAD SHX Text L-12
AutoCAD SHX Text W8x18 + L3½x3½x1/4 + PL 1/4"x1'-1", 13'-4 LONG
AutoCAD SHX Text 17'-4"
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
GRIND/POLISH
AutoCAD SHX Text
EPOXY PAINT
AutoCAD SHX Text
GYPSUM BOARD
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
VINYL
AutoCAD SHX Text 2x2 ACT
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
ENTRY VESTIBULE
AutoCAD SHX Text
GRIND/POLISH
AutoCAD SHX Text
EPOXY PAINT
AutoCAD SHX Text
GYPSUM BOARD
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
VINYL
AutoCAD SHX Text
GRIND/POLISH
AutoCAD SHX Text
EPOXY PAINT
AutoCAD SHX Text
GYPSUM BOARD
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
VINYL
AutoCAD SHX Text ALL EXISTING DOORS AND FRAMES IN ROOMS WHERE WORK IS BEING COMPLETED ARE TO BE PAINTED BOTH SIDES
AutoCAD SHX Text
TUEBOR
AutoCAD SHX Text U
AutoCAD SHX Text S
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text U
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text
KAB
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text U
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text S
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text M
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text U
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text
ADDENDUM #1 7-19-2023
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
GRIND/POLISH
AutoCAD SHX Text
EPOXY PAINT
AutoCAD SHX Text
GYPSUM BOARD
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
PAINTED CMU
AutoCAD SHX Text
VINYL
| FORM BF-1 |
| ADDENDUM NO. 1 |
| FIRM NAME |
| Kurt Maiberger |
| BIDDER'S SIGNATURE Construction & Facilities |
| Management Office |
| 085113 ALUMINUM WINDOWS 24005 Addendum 1.pdf |
| PART 1 - GENERAL |
| 1.1 SUMMARY |
| A. Section includes aluminum windows for exterior locations. |
| 1.2 SUBMITTALS |
| A. Product Data: For each type of product. |
| B. Shop Drawings: Include plans, elevations, sections, hardware, accessories, operational clearances, and details of installation, including anchor, flashing, and sealant installation. |
| C. Samples: For each exposed product and for each color specified. |
| D. Product Schedule: For aluminum windows. Use same designations indicated on Drawings. |
| E. Product test reports. |
| F. Sample warranties. |
| 1.3 WARRANTY |
| A. Manufacturer's Warranty: Manufacturer agrees to repair or replace aluminum windows that fail in materials or workmanship within specified warranty period. |
| 1. Failures include, but are not limited to, the following: |
| a. Failure to meet performance requirements. |
| b. Structural failures including excessive deflection, water leakage, condensation, and air infiltration. |
| c. Faulty operation of movable sash and hardware. |
| d. Deterioration of materials and finishes beyond normal weathering. |
| e. Failure of insulating glass. |
| 2. Warranty Period: |
| a. Window: 10 years from date of Substantial Completion. |
| b. Glazing Units: 10 years from date of Substantial Completion. |
| c. Aluminum Finish: 10 years from date of Substantial Completion. |
| B. Contractor’s Warranty: Contractor agrees to repair or replace aluminum windows that fail in installation workmanship within specified warranty period. |
| 1. Warranty Period: |
| a. 3 years from date of Substantial Completion. |
| PART 2 - PRODUCTS |
| 2.1 MANUFACTURERS |
| A. Basis-of-Design Product: Subject to compliance with requirements, provide EFCO Corporation, FX32 Thermal, AW150, 3-1/4" frame depth, inside glazed, Fixed windows or a comparable product by one of the following: |
| 1. EFCO Corporation; a Pella company. |
| 2. Gerkin Windows and Doors. |
| 3. Kawneer North America; an Alcoa company. |
| 4. TRACO. |
| 5. Wausau Window and Wall Systems. |
| 2.2 WINDOW PERFORMANCE REQUIREMENTS |
| A. Product Standard: AAMA/WDMA/CSA 101/I.S.2/A440. |
| 1. Minimum Performance Class: AW-150. |
| 2.3 ALUMINUM WINDOWS |
| A. Operating Types: As indicated on Drawings. |
| B. Frames and Sashes: Thermally broken aluminum extrusions complying with AAMA/WDMA/CSA 101/I.S.2/A440. |
| C. Insulating-Glass Units: ASTM E 2190. |
| 1. Glass: ASTM C 1036, Type 1, Class 1, q3. |
| a. Tint: Clear. |
| b. Double pane insulated high-performance glass of 1" total thickness. |
| c. Exterior Board - 3/16" thick, heat strengthened, clear. |
| d. Interior Board - 3/16" thick, annealed, clear. |
| e. Low-E coating shall be applied to surface #3 equal to PPG Solarban 60. |
| D. Glazing System: Manufacturer's standard factory-glazing system that produces weathertight seal. |
| E. Hardware, General: Manufacturer's standard corrosion-resistant hardware sized to accommodate sash weight and dimensions. |
| 1. Exposed Hardware Color and Finish: As selected by Design Professional from manufacturer's full range. |
| F. Weather Stripping: Provide full-perimeter weather stripping for each operable sash unless otherwise indicated. |
| G. Fasteners: Noncorrosive and compatible with window members, trim, hardware, anchors, and other components. |
| 1. Exposed Fasteners: Do not use exposed fasteners to the greatest extent possible. For application of hardware, use fasteners that match finish hardware being fastened. |
| 2.4 ACCESSORIES |
| A. Interior Trim: Extruded-aluminum profiles in sizes and configurations indicated on Drawings. |
| B. Panning Trim: Extruded-aluminum profiles in sizes and configurations indicated on Drawings. |
| C. Receptor System: Two-piece, snap-together, thermally broken, extruded-aluminum receptor system that anchors windows in place. |
| 2.5 FABRICATION |
| A. Fabricate aluminum windows in sizes indicated. Include a complete system for assembling components and anchoring windows. |
| B. Glaze aluminum windows in the factory. |
| C. Provide weep holes and internal passages to conduct infiltrating water to exterior. |
| D. Provide water-shed members above side-hinged sashes and similar lines of natural water penetration. |
| E. Provide cover plates, matching window units, complete with anchors for support to structure and installation of window units. Allow for erection tolerances and provide for movement of window units due to thermal expansion and building deflections, ... |
| F. Complete fabrication, assembly, finishing, hardware application, and other work in the factory to greatest extent possible. Disassemble components only as necessary for shipment and installation. |
| 2.6 ALUMINUM FINISHES |
| A. Anodic Finish: Class I complying with AAMA 611. |
| 1. Color: Dark bronze. |
| PART 3 - EXECUTION |
| 3.1 INSTALLATION |
| A. Comply with manufacturer's written instructions for installing windows, hardware, accessories, and other components. For installation procedures and requirements not addressed in manufacturer's written instructions, comply with installation require... |
| B. Install windows level, plumb, square, true to line, without distortion or impeding thermal movement, anchored securely in place to structural support, and in proper relation to wall flashing and other adjacent construction to produce weathertight c... |
| C. Install windows and components to drain condensation, water penetrating joints, and moisture migrating within windows to the exterior. |