26365 MSHP Day Use Restroom - Addendum 1.pdf
PDF 2 MB Posted
- Solicitation number
- RFQ 171 260000000468 2
- Issued by
- Livingston County, Mcbride Village, Michigan
About this file
This is Addendum No. 1 to a construction contract issued by the Michigan Department of Natural Resources (DNR) for the Colonial Michilimackinac MSHP Day Use Restroom renovation project located in Mackinac City, Michigan. The addendum, issued October 6, 2026, clarifies and modifies the original plans and specifications prepared by UP Engineers and Architects, Inc. Key modifications include the addition of Section 10 28 00 covering toilet, bath, and laundry accessories to the specifications; replacement of drawings A101 and A201 with revised versions; and the addition of a new Site Plan (C101). The addendum also establishes responsibility for snow removal, with MSHP responsible for parking lot clearance and the contractor responsible for site access and work area clearing. A mandatory pre-bid walkthrough was conducted with an attached sign-in sheet and pre-bid meeting agenda provided. Material testing results for lead, cadmium, and asbestos are included, with paint analysis from samples taken at the exterior soffit location showing cadmium levels of 31.7 mg/kg.
The addendum specifies four additional light fixture options for the project, including models from Metalux, HALO, Luminaire LED, and EVENLITE manufacturers. The project file number is 751/26365.ABG with UP Engineers and Architects order number 713454. Material testing was performed by Schneider Laboratories Global, Inc. in Richmond, Virginia, with analysis completed on September 28, 2026. Bidders were required to acknowledge receipt of Addendum No. 1 on their bid forms and include the addendum with their bid packages.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
707 Ashmun Street Sault Ste. Marie, MI 49783
906-635-0511 • 800-867-0511 • Fax: 906-635-0612
Offices also in:
Houghton
Iron Mountain Ishpeming Marinette
U.P. Engineers & Architects, Inc. www.UPEA.com
[M12-06362]
ADDENDUM NO. 1
TO THE
DNR/Colonial Michilimackinac MSHP Day Use Restroom Mackinac City, MI
ADDENDUM NO. 1 is issued October 6, 2026, to clarify, modify, and/or change the original plans and specifications issued by UP Engineers and Architects. This ADDENDUM NO. 1 is hereby made part of the Contract Documents for the contract noted below.
File No. 751/26365.ABG DNR/Colonial Michilimackinac MSHP Day Use Restroom
Please acknowledge receipt of this ADDENDUM NO. 1 on the appropriate blank on the Bid Form and also include this addendum with the bid package.
GENERAL
1. See attached mandatory pre-bid walkthrough sign-in sheet.
2. See the attached pre-bid meeting agenda.
3. See the attached paint and material testing results for lead, cadmium and asbestos.
SPECIFICATIONS
4. Add the attached SECTION 10 28 00 TOILET, BATH, AND LAUNDRY ACCESSORIES to the specifications.
PLANS
5. Add the attached C101 SITE PLAN to the drawings
6. Replace A101 and A201 with the attached revised drawings.
7. AD100 – Add GENERAL NOTE: MSHP WILL BE RESPONSIBLE FOR SNOW
REMOVAL FOR THE PARKING LOT. CONTRACTOR WILL BE
RESPONSIBLE FOR SNOW REMOVAL FOR ACCESS FROM THE PARKING
LOT AND AROUND THE SITE AS NECESSARY FOR THE WORK.
8. AD101 – Add GENERAL NOTE: EXISTING CEILING IS LATH AND PLASTER
9. E505 LIGHT FIXTURE SCHEDULE – Add the following as additional light fixtures
Type A: Metalux model # 4PWM-2060C5 Type B: HALO model # SMX8SLSFS010 Type C: Luminaire LED model # SWP1212-NODIM-25W-40K-MVOLT-
OP-BRZ
Type EM: EVENLITE model # WW-EM-BZ-CT
END OF ADDENDUM NO. 1
Prepared by:
U.P. Engineers & Architects, Inc
Attn:
Address: 424 South Pine Street Order #: 713454
Ishpeming, MI 49849
Project: MSHP Day Use Restroom Reno
UP Engineers & Architects, Inc. (2716)Customer:
M12-06362Number: PO Number:
Received 09/28/26
Schneider Laboratories Global, Inc 2512 W. Cary Street • Richmond, Virginia • 23220-5117 804-353-6778 • 800-785-LABS (5227) • Fax 804-359-1475
Location: Mackinac Restroom
09/28/26Reported
Analysis Report
Cust. Sample ID
Parameter
Sample ID Location
UnitsRL* AnalystAnalysis DateResultMethod
Matrix Paint
713454-001 100 Ext Soffit Tan
Metals Analysis
Cadmium mg/kg DM09/28/2631.7<31.8EPA 6010D / ME-003
Lead mg/kg DM09/28/2631.7977EPA 6010D / ME-003
713454-002 101 Ext Win Tan
Metals Analysis
Cadmium mg/kg DM09/28/266.3718.4EPA 6010D / ME-003
Lead mg/kg DM09/28/2663735800EPA 6010D / ME-003
713454-003 102 Storage Ceiling White
Metals Analysis
Cadmium mg/kg DM09/28/266.6490.9EPA 6010D / ME-003
Lead mg/kg DM09/28/2666.43280EPA 6010D / ME-003
713454-09/28/26 04:57 PM
Analyst
Reviewed By: Ahmed Elnasseh
Method Parameter Michigan Virginia
State Certifications
Cadmium No state cert. necessary VELAP CertifiedEPA 6010D
Lead No state cert. necessary VELAP CertifiedEPA 6010D
State Certificate Number
Virginia VELAP 14319
All internal QC parameters were met. Unusual sample conditions, if any, are described. Surrogate Spike results designated with "D" indicate that the analyte was diluted out. "MI" indicates matrix interference. Concentration and *Reporting Limit (RL) based on areas provided by client. Values are reported to three significant figures. Solid PPM = mg/kg | PPB = µg/kg and Water PPM = mg/L | PPB = µg/L. The test results apply to the sample as received.
Attn:
Address: 424 South Pine Street Order #: 713453
Ishpeming, MI 49849
UP Engineers & Architects, Inc. (2716)Customer:
Received 09/28/26
Schneider Laboratories Global, Inc 2512 W. Cary Street • Richmond, Virginia • 23220-5117 804-353-6778 • 800-785-LABS (5227) • Fax 804-359-1475
10/04/26Analyzed
10/05/26Reported
Analysis Report
PLM Analysis
Cust. IDSample ID LocationCollected Asbestos Fibers Other Materials
EPA 600/R-93/116 & 40 CFR App. E Sub. E Pt. 763Method:
Project: MSHP Day Use Restroom
M12-06362Number:
Location: Mackinac Restroom
Mackinac Restroom09/23/26 1A713453-001
Tan/Black, Bituminous
ShingleLayer 1: No Asbestos Detected
Sample was inhomogenous, subsamples of each component were analyzed separately.
MINERAL/GLASS WOOL20%
NON FIBROUS MATERIAL80%
Black, Bituminous/Fibrous
UnderlaymentLayer 2: No Asbestos Detected MINERAL/GLASS WOOL55%
NON FIBROUS MATERIAL45%
West Side09/23/26 2A713453-002
Gray, Granular
Window GlazingLayer 1: NON FIBROUS MATERIAL98%2% CHRYSOTILE
Mens Bath09/23/26 3A713453-003
Gray, Granular
Ceiling PlasterLayer 1: No Asbestos Detected NON FIBROUS MATERIAL100%
Mens Bath09/23/26 4A713453-004
Gray, Granular
GroutLayer 1: No Asbestos Detected NON FIBROUS MATERIAL100%
Storage Ceiling Room09/23/26 5A713453-005
Gray, Granular
Ceiling PlasterLayer 1: No Asbestos Detected NON FIBROUS MATERIAL100%
Mackinac Restroom09/23/26 6A713453-006
Gray, Granular
MortarLayer 1: No Asbestos Detected NON FIBROUS MATERIAL100%
Reporting Limit: 1% Gravimetrically Reduced Reporting Limit: 0.01% PLM analysis is based on Visual Estimation and NESHAP recommends that any friable sample with an asbestos content less than 10 percent be verified by Point Count or TEM Analysis. The EPA recommends that any attic loose fill vermiculite should be treated as asbestos containing material. This report must not be reproduced except in full with the approval of the laboratory. Laboratory estimated asbestos error rates available upon request. The test results apply to the sample as received.
PLM Analysis
Cust. IDSample ID LocationCollected Asbestos Fibers Other Materials
EPA 600/R-93/116 & 40 CFR App. E Sub. E Pt. 763Method:
Project: MSHP Day Use Restroom
M12-06362Number:
Location: Mackinac Restroom
Laboratory Director
Reviewed By: Ben Wood
Total layers analyzed on order: 7 713453-10/05/26 03:09 PM
EPA Regulatory Limit: 1%
Analyst Elsamani Abdelfadiel
Reporting Limit: 1% Gravimetrically Reduced Reporting Limit: 0.01% PLM analysis is based on Visual Estimation and NESHAP recommends that any friable sample with an asbestos content less than 10 percent be verified by Point Count or TEM Analysis. The EPA recommends that any attic loose fill vermiculite should be treated as asbestos containing material. This report must not be reproduced except in full with the approval of the laboratory. Laboratory estimated asbestos error rates available upon request. The test results apply to the sample as received.
DTMB Day Use Restroom Renovations 102800 - 1 Toilet, Bath, And Laundry
Accessories
SECTION 102800
TOILET, BATH, AND LAUNDRY ACCESSORIES
PART 1 GENERAL
1.1 SUMMARY
A. Section Includes:
1. Toilet and Shower Room accessories.
B. Related Requirements:
1. Section 061000 - Rough Carpentry: Concealed wood framing and blocking for support of accessories.
2. Section 260503 – Equipment Wiring
1.2 REFERENCE STANDARDS
A. ASTM International:
1. ASTM A123 - Standard Specification for Zinc (Hot Dip Galvanized) Coatings on Iron and
Steel Products.
2. ASTM A153 - Standard Specification for Zinc Coating (Hot Dip) on Iron and Steel
Hardware.
3. ASTM A269 - Standard Specification for Seamless and Welded Austenitic Stainless Steel
Tubing for General Service.
4. ASTM A653 - Standard Specification for Steel Sheet, Zinc Coated (Galvanized) or Zinc
Iron Alloy Coated (Galvannealed) by the Hot Dip Process.
5. ASTM A666 - Standard Specification for Annealed or Cold Worked Austenitic Stainless
Steel Sheet, Strip, Plate, and Flat Bar.
6. ASTM B456 - Standard Specification for Electrodeposited Coatings of Copper Plus
Nickel Plus Chromium and Nickel Plus Chromium.
7. ASTM C1036 - Standard Specification for Flat Glass.
1.3 COORDINATION
A. Coordinate Work of this Section with placement of reinforcement of toilet partitions to receive anchor attachments.
1.4 SUBMITTALS
A. Product Data: Submit data on accessories, describing size, finish, details of function, and attachment methods.
B. Manufacturer's Instructions: Submit special installation procedures, conditions requiring special attention, and maintenance requirements.
1.5 QUALIFICATIONS
A. Manufacturer: Company specializing in manufacturing products specified in this Section with minimum ten years' experience.
1.6 WARRANTY
A. Furnish ten-year manufacturer's warranty for electric hand dryers.
Renovations 102800 - 2 Toilet, Bath, And Laundry
Accessories
B. Furnish fifteen-year manufacturer's warranty for mirror glass and stainless steel mirror frames.
PART 2 PRODUCTS
2.1 TOILET AND SHOWER ROOM ACCESSORIES
A. Manufacturers:
1. American Specialties, Inc.
2. Bobrick Washroom Equipment
3. Bradley Corporation
4. Koala Kare
5. Grab Bar Specialist
6. Georgia Pacific
7. GOJO
8. Global Industries.
9. World Dryer
10. Substitutions: Section 016000 - Product Requirements.
B. Performance and Design Criteria:
1. Design grab bars and attachments to resist minimum 250 lb concentrated load applied at any point in any direction.
2.2 MATERIALS
A. Accessories: Shop assembled, free of dents and scratches, and packaged complete with anchors and fittings, steel anchor plates, adapters, and anchor components for installation.
1. Grind weld joints smooth.
2. Fabricate units made of metal sheet of seamless sheets with flat surfaces.
3. Install 2x blocking in wall at grab bars, shower seats and shelves.
B. Keys: Furnish two keys for each keyed accessory to Owner.
C. Stainless Steel Sheet: ASTM A666, Type 304.
D. Stainless Steel Tubing: ASTM A269, Type 304 stainless steel.
E. Galvanized Sheet Steel: ASTM A653, G90 zinc coating.
F. Mirror Glass (Type MR-F): ASTM C1036, Type 1 transparent flat, Class 1 clear, Quality Q2 mirror; type with copper and silver coating, and organic overcoating.
G. Adhesive: Two-component epoxy type, waterproof.
H. Fasteners, Screws, and Bolts: Hot-dip galvanized, tamper-proof.
I. Expansion Shields: Fiber, lead, or rubber as recommended by accessory manufacturer for component and substrate.
2.3 FINISHES
A. Stainless Steel: No. 4 satin brushed finish, unless otherwise indicated.
B. Chrome/Nickel Plating: ASTM B456, satin finish.
C. Baked Enamel: Pretreat to clean condition, apply one coat primer and minimum two coats baked enamel.
Renovations 102800 - 3 Toilet, Bath, And Laundry
Accessories
D. Galvanizing: ASTM A123; hot-dip galvanize after fabrication.
E. Galvanizing for Nuts, Bolts, and Washers: ASTM A153.
F. Shop-Primed Ferrous Metals: Pretreat and clean, spray apply one coat primer and bake.
G. Back paint components where contact is made with building finishes to prevent electrolysis.
2.4 TOILET ROOM AND SHOWER ROOM ACCESSORIES
A. All model numbers and manufacturers listed are the Basis of Design. Substitutions may be permitted according to Section 016000 of the specifications.
B. Mirrors:
1. Size: 24”x36” or as indicated on Drawings.
2. Frame: 0.05 inch channel shapes, with mitered, welded, and ground corners, and tamper-proof hanging system; bright annealed finish.
3. Backing: Full mirror sized, minimum 0.03 inch galvanized steel sheet and nonabsorptive filler material.
C. Toilet Paper Dispensers: Double roll dispenser with shelf standard core roll; basis for design:
Bradley.
D. Soap Dispensers: Basis for design: GOJO manual 2,000 ml foam, model #5271-06, color black/chrome
E. Sanitary Napkin Dispenser: Basis for Design: Bobrick B-270, Contura Series
1. 18-8 S, type 304, 22 gauge, stainless steel, all welded construction.
2. Include minimum 12 additional liners, equal to part number Bobrick 270-12.
F. Diaper-Changing Station: Basis for Design: Koala Kare KB208 Baby Changing Station
1. Mounting: Surface mounted.
2. Operation: By pneumatic shock-absorbing mechanism.
G. Grab bars: Stainless steel, 1-1/2” outside diameter, minimum 0.05” wall thickness, nonslip grasping surface, concealed flange mounting; 1-1/2” clear between wall and inside of grab bar.
1. Length and configuration: As indicated on Drawings.
2. Model: 812 Series, manufactured by Bradley.
2.5 CUSTODIAL ACCESSORIES
A. Provide and install (1) each at new janitor sinks.
1. Utility shelf with mop/broom holders and rag hooks; basis for design: Bobrick B-239.
2. Single hose bracket; basis for design: Ferguson’s Proflo Model PF296.
3. Service sink hose; basis for design: Ferguson’s Proflo PFSSHE, 5/8” x 30”.
4. Stainless steel wall shelf; basis for design: Regency Model 600WS1224HD.
5. Stainless steel wall guard; basis for design: Ferguson’s Proflo Model PFWG24S, 12” high.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify exact location of accessories for installation.
B. Verify field measurements and rough-in dimensions for recessed accessories are as instructed by manufacturer.
Renovations 102800 - 4 Toilet, Bath, And Laundry
Accessories
3.2 PREPARATION
A. Deliver inserts and rough-in frames to Site for timely installation.
B. Provide templates and rough-in measurements as required.
3.3 INSTALLATION
A. Do not install accessories until after completion of all finishes to adjacent wall and ceiling surfaces.
B. Install plumb and level, securely and rigidly anchored to substrate.
C. Turn over to Owner all keys and special tools required for lockable or secured accessories.
D. Mounting Heights and Locations: As required by accessibility regulations.
E. Hand dryers: provide dedicated circuit with GFI protection.
3.4 CLEANING
A. Clean mirrors and exposed surfaces using procedures as recommended by accessory manufacturer.
3.5 SCHEDULE
A. Reference Toilet Accessory Schedule on Drawing Sheet A401.
END OF SECTION
V.
I.F
5' - 0"
5' - 6"
DOWEL INTO EXISTING CONCRETE
#5 18" BARS @ 16" O.C. EMBEDDED 8" INTO EXISTING CONCRETE
4' - 6"
CLEARANCE
5' - 0" MIN.
C
LE
AR
AN
C E
5'
0" M
IN
C101
DOWEL INTO EXISTING CONCRETE
#5 18" BARS @ 16" O.C. EMBEDDED 8" INTO EXISTING CONCRETE
DEMO CONCRETE FOR
INSTALLATION OF NEW RAMPS
AND EXTENDED WALK-WAY
COMPACTED SUBGRADE OR EMBANKMENT FILL
C O
N C
R
ET
E W
AL
K
4" C
LA
SS
II
, C
.I.
P.
" M
D O
T
MEDIUM BROOM FINISH
PERPENDICULAR TO
WALK DIRECTION
1/2" EXPANSION JOINT MATERIAL TO BE PLACED
BETWEEN NEW EXTERIOR SLAB AND EXISTING
CONCRETE APRON
CONTROL JOINT FOR SIDEWALK TO BE PLACED EVERY 6'
6" x 6" #10 MESH
STAINLESS STEEL SET SCREWS
1 1/4" ALUMINUM PEG
2" GALVANIZED POST
1 2 3 4 5
1 2 3 4 5
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T N
O:
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R
D
A
TE
P:
\M
-0
D
TM
B- M
SH
P
D ay
U se
R es tro om
R en ov at io ns
\D es ig n\
D ra w in gs \M
-0
.rv t
/6
/2
9:
:4
AM
C101
SITE PLAN
ST
A
TE
O
F M
IC
H
IG
A
N M
A C
K
IN
A C
S
TA
TE
H
IS
TO
R
IC
P A
R K
M
SH
P D
A Y
U
SE
R
ES
TR
O
O M
S R
EM
O
D
EL
N H ur on
A ve
, M ac ki na w C ity , M
I 4
M
-0
G S
JGG
S
ST
A
TE
O
F M
IC
H
IG
A
N M
A C
K
IN
A C
S
TA
TE
H
IS
TO
R
IC
P A
R K
M
SH
P D
A Y
U
SE
R
ES
TR
O
O M
S R
EM
O
D
EL
AD
D
EM
D
U M
-5
-2
1/4" = 1'-0"2 PROPOSED SITE PLAN
1/4" = 1'-0"1 DEMOLITION SITE PLAN
1" = 1'-0"3 SIDEWALK DETAIL
1" = 1'-0"4 RAILING CONNECTION DETAIL
RAILING DETAILS PER "CHAPTER 4: RAMPS AND CURB RAMPS - HANDRAILS"
OF THE US ACCESS BOARD ADA TECHNICAL GUIDE
A201
A201
A2016
MENS
WOMENS
FAMILY RESTROOM
N
EW
L
AN
D
IN
G W
ID
TH
5'
6" N
EW
R
AM
P
LE
N
G
TH
7'
9" N
EW
R
AM
P
AN
D
L
AN
D
IN
G W
ID
TH
5'
6"
BABY CHANGING
STATION
NEW WINDOWS IN
EXISTING MASONRY
OPENINGS (TYP.)
NEW FLUID APPLIED EPOXY
FLOORING
NEW FLUID APPLIED EPOXY
FLOORING
NEW TOILETES
MOP
SINK
JANITOR CLO.
NEW WINDOWS IN
EXISTING MASONRY
OPENINGS (TYP.)
NEW TOILET STALL
PARTITIONS (TYP.)
NEW TOILET STALL
PARTITIONS (TYP.)
A201 5
A202
2A
2C
2B 2D
A202
1A
1C
1D 1B
A202 3A
3D
3C
3B
A301
A301
A201 1 A2012
A201
A201
B2 ø 5' - 7
A1A1A1
NEW WALL TILE ON
FIBER CEMENT BACKER
BOARD ON ALL
PERIMETER WALLS
SEE SHEET A601 FOR
WALL SCHEDULE
NEW WALL TILE ON
FIBER CEMENT BACKER
BOARD ON ALL
PERIMETER WALLS
SEE SHEET A601 FOR
WALL SCHEDULE
104A
NEW LANDING
4' - 11"
NEW RAMP
7' - 9"
12' - 8"
NEW RAMP WIDTH
5' - 6"
NEW LANDING LENGTH
18' - 2"
1"
1' -0
1" / 1'-0"
SL
OP
E
SLOPE
A301
A501
A301
A501
NEW URINALS NEW LAVS
NEW LAVS
NEW 2'x 3' MIRROR
ABOVE EACH SINK
NEW 2'x 3' MIRROR
ABOVE EACH SINK
NEW 2'x 3' MIRROR
ABOVE EACH SINK
NEW 2'x 3' MIRROR
ABOVE EACH SINK
NEW HANDRYER
NEW HAND DRYER
NEW HANDRYER
3' - 4" 3' - 4" 3' - 4" 3' - 4"
6' - 6" 3' - 4" 3' - 4" 3' - 4" 3' - 4"
A1 A1 A1 A1 A1 A1
A1 A1 A1
CONTROL JOINTS
ADA STALL
ADA STALL
7" 7"
7"
5'
1"
6' - 6"
DUAL STAINLESS STEEL TOILET
PAPER DISPENSERS MOUNTED
O.C. 7" FORM FACE OF TOILET
DUAL STAINLESS STEEL TOILET
PAPER DISPENSERS MOUNTED
O.C. 7" FROM FACE OF TOILET
DUAL STAINLESS STEEL TOILET
PAPER DISPENSERS MOUNTED
O.C. 7" FROM FACE OF TOILET
(1) SAMITARY NAPKIN
DISPOSAL PER STALL IN
WOMEN'S RESTROOM
ADA GRAB BARS MOUNTED
PER SHEET A001
5'
1"
1'
6"
EXISTING POST
EXISTING POST
5 1/2" 3' - 0" 5 1/2" 3' - 0" 3' - 3 1/4" 3' - 0" 5 1/2" 3' - 0" 3' - 3 1/4" 3' - 0" 5 1/2" 3' - 0" 5 1/2"
5 1/2" 3' - 0" 5 1/2" 3' - 0" 3' - 3 1/4" 3' - 0" 5 1/2" 3' - 0" 3' - 3 1/4" 3' - 0" 5 1/2" 3' - 0" 5 1/2"
SOFFIT ABOVE
FUR OUT WALL FOR PLUMBING
TO DRINKING FOUNTAINS
SEE PLUMBING PLANS FOR
DRINKING FOUNTAIN DETAILS
PIPES TO BE SLOPED AS SHOWN
IN PLUMBING DETAILS FOR
DRAINING AND WINTERIZING
A301
6x6/6 WWF
6x6/6 WWF
A301
C101
2" GALVANIZED RAIL SYSTEM
SEE ELEVATIONS ON SHEET A201
AND DETAILS ON SHEET C101
2" GALVANIZED RAIL SYSTEM
SEE ELEVATIONS ON SHEET A201
AND DETAILS ON SHEET C101
1 2 3 4 5
1 2 3 4 5
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T N
O:
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R
D
A
TE
P:
\M
-0
D
TM
B- M
SH
P
D ay
U se
R es tro om
R en ov at io ns
\D es ig n\
D ra w in gs \M
-0
.rv t
/6
/2
9:
:4
AM
A101
PROPOSED
FLOOR PLAN
ST
A
TE
O
F M
IC
H
IG
A
N M
A C
K
IN
A C
S
TA
TE
H
IS
TO
R
IC
P A
R K
M
SH
P D
A Y
U
SE
R
ES
TR
O
O M
S R
EM
O
D
EL
N H ur on
A ve
, M ac ki na w C ity , M
I 4
M
-0
D C
/G S
JA JGD
C
/G S
ST
A
TE
O
F M
IC
H
IG
A
N M
A C
K
IN
A C
S
TA
TE
H
IS
TO
R
IC
P A
R K
M
SH
P D
A Y
U
SE
R
ES
TR
O
O M
S R
EM
O
D
EL
1/2" = 1'-0"A1 PROPOSED FLOOR PLAN
TYP.
O W
N
ER
R
EV
IE
W
6-
-2
O W
N
ER
R
EV
IE
W
7-
-2
PR
O
G R
ES
S
SE
T
8-
-2
R
EV
IE
W
8-
-2
R
EV
IE
W
8-
-2
R
EV
IE
W
9- 9-
BI
D
SE
T 9-
-2
AD
D
EM
D U
M
-5 -2
PAINT EXISTING WOOD PANELS IN GABLE ENDS
B2
M
AX
2'
3"
MIN
1' - 0"
MAX
6' - 0"
2'
6" 6"
A1 A1 A1 A1 A1 A1
2'
6" 6"
MAX
6' - 0"
A301
INFILL W/ CERTAINTEED COMPOSITE
PANEL IN NATURAL CLAY
SEE DETAIL 5 ON SHEET 301
A1 A1 A1A1 A1 A1
A301
MIN
1' - 0"
M
AX
2'
3"
6" 2'
6"
MAX
6' - 0"
1 2 3 4 5
1 2 3 4 5
D
C
B
A
D
C
B
A
© U.P. Engineers & Architects, Inc.
PR
OJ
EC
T N
O:
DR
AW
N
BY
CH
EC
KE
D:
AP
PR
OV
ED
DE
SI
GN
ED
B Y:
w w w .u pe a.
co m
IS
SU
ED
F
O R
D
A
TE
P:
\M
-0
D
TM
B- M
SH
P
D ay
U se
R es tro om
R en ov at io ns
\D es ig n\
D ra w in gs \M
-0
.rv t
/6
/2
9:
:5
AM
A201
EXTERIOR
ELEVATIONS
ST
A
TE
O
F M
IC
H
IG
A
N M
A C
K
IN
A C
S
TA
TE
H
IS
TO
R
IC
P A
R K
M
SH
P D
A Y
U
SE
R
ES
TR
O
O M
S R
EM
O
D
EL
N H ur on
A ve
, M ac ki na w C ity , M
I 4
M
-0
G S
JA JGG
S
ST
A
TE
O
F M
IC
H
IG
A
N M
A C
K
IN
A C
S
TA
TE
H
IS
TO
R
IC
P A
R K
M
SH
P D
A Y
U
SE
R
ES
TR
O
O M
S R
EM
O
D
EL
1/4" = 1'-0"5 EAST ELEVATION
1/4" = 1'-0"6 WEST ELEVATION
1/4" = 1'-0"7 NORTH ELEVATION
1/4" = 1'-0"8 SOUTH ELEVATION
1/4" = 1'-0"1 EAST ELEVATION DEMO
1/4" = 1'-0"2 WEST ELEVATION DEMO
1/4" = 1'-0"4 SOUTH ELEVATION DEMO
1/4" = 1'-0"3 NORTH ELEVATION DEMO
DEMO LOUVERS AND EXTERIOR PANELLING
PREP FOR NEW WINDOWS
DEMO ALL EXISTING EXTERIOR DOORS, FRAMES, AND WINDOWS
DEMO WOOD AND CONCRETE RAMPS AND LANDINGS BOTH SIDES
DEMO ALL EXISTING SOFFIT AND FASCIA, TYP.
NEW VENTED SOFFIT AND FASCIA
WRAP COLUMNS IN NEW COMPOSITE FINISH TYP.
NEW CONCRETE RAMP AND LANDING TO ACCOMMODATE FAMILY RESTROOM NEW CONCRETE RAMP AND LANDING
INSTALL NEW DOORS, WINDOWS, AND FRAMES
NEW VENTED SOFFIT AND FASCIA
WRAP COLUMNS IN NEW FINISH TYP.
NEW CONCRETE RAMPS AND LANDINGS
NEW WINDOWS
DEMO EXISTING SHINGLES,
UNDERLAYMENT, AND DRIP EDGE
NEW RIDGE VENT
DEMO ALL EXISTING EXTERIOR
DOORS, FRAMES, AND WINDOWS
DEMO WOOD AND CONCRETE RAMPS AND LANDINGS BOTH SIDES
DEMO ALL EXISTING SOFFIT AND FASCIA,
TYP.
DEMO EXISTING SHINGLES,
UNDERLAYMENT, AND DRIP EDGES
DEMO FOR NEW MECH LOUVERS
COORDINATE WITH MECHANICAL
NEW MECHANICAL LOUVERS
COORDINATE WITH MECHANICAL
NEW MECHANICAL LOUVERS
COORDINATE WITH MECHANICAL
NEW MECHANICAL LOUVERS
COORDINATE WITH MECHANICAL
PAINT EXISTING WOOD PANELS IN GABLE ENDS
NEW SHINGLES AND UNDERLAYMENT
NEW PLUMBING VENT NEW PLUMBING VENT
NEW PLUMBING VENTNEW PLUMBING VENT
POSTS TO REMAIN, TYP.
NEW CERTAINTEED COMPOSITE PANEL
SIDING AND TRIM IN NATURAL CLAY
NEW CERTAINTEED COMPOSITE PANEL SIDING
AND TRIM IN NATURAL CLAY @ AREAS OF
INFILL TYP.
SEE PLUMBING SHEETS FOR NEW DRINKING FOUNTAIN DETAILS
SEE PLUMBING SHEETS FOR NEW
DRINKING FOUNTAIN DETAILS
PREP AND APPLY BRICK WATER
REPELANT SEALANT PER SPECS
PREP AND APPLY BRICK WATER
REPELANT SEALANT PER SPECS
PREP AND APPLY BRICK WATER
REPELANT SEALANT PER SPECS
PREP AND APPLY BRICK WATER REPLANT
SEALANT PER SPECS
O W
N
ER
R
EV
IE
W
6-
-2
O W
N
ER
R
EV
IE
W
7-
-2
PR
O
G R
ES
S
SE
T
8-
-2
R
EV
IE
W
8-
-2
R
EV
IE
W
8-
-2
R
EV
IE
W
9- 9-
BI
D
SE
T 9-
-2
AD
D
EM
D U
M
-5 -2
NEW RAILINGS
| Addendum No. 1.pdf |
| Meeting Attendance.pdf |
| Pre-bid Meeting Agenda.pdf |
| 713454 Attachment 09-29-26 0857AM.pdf |
| 102800-Toilet, Bath, And Laundry Accessories.pdf |
| M12-06362_MSHP RESRTROOM RENOVATIONS_ADDENDUM 01_10.8.26.pdf |
File details come from the government source that posted it. Updated .