261013 - CSSPTF Drawings - Amendment.pdf

PDF 1 MB Posted

Attached to
Trade and Cargo Academy
Solicitation number
W912HP27RA002-0003
Issued by

About this file

This document is a set of architectural and mechanical design drawings for the Cargo Security and Seized Property Training Facility (CSSPTF) located at 2000 Bainbridge Avenue, North Charleston, South Carolina, prepared for the Department of Homeland Security Federal Law Enforcement Training Center and Customs & Border Patrol.

The drawings include structural floor plans, mechanical equipment schedules, and HVAC system specifications. Key structural elements shown on the first floor slab plan include a 10-inch concrete slab at elevation 100'-0", recessed loading docks with 3 bays, roll-up doors (6 locations), W8x31 and W10x68 columns, and masonry walls with flood vents. The mechanical systems include an energy recovery unit (ERU-1, Oxygen 8 Nova B20) with 1,185 CFM capacity, a heating and cooling unit (HC-1, Oxygen 8 3EN1405A) with 1,185 CFM and 43 MBH total cooling capacity, multiple ductless air conditioning units (DAC-1 through DAC-12) ranging from 1.0 to 1.5 tons matched to Daikin heat pumps (HP-1 through HP-5), and a condensing unit (CU-1, Daikin RKF12BVJU9) with 1.0 tons refrigeration capacity using R32 refrigerant. All equipment is rated for 208V, 1-phase, 60Hz operation. The facility includes inspection rooms, high-risk vaults, evidence processing areas, mechanical/electrical/plumbing rooms, and classroom spaces. Design drawings are dated with final submittal on 08/10/26, RTA on 09/08/26, and revision per Amendment 001 on 10/13/26.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RTA

SUBMITTAL NOT

FOR

CONSTRUCTION

INDEX: 2 OF 106

BarretR2 Snapshot

BarretR2 Snapshot

BarretR2 Cloud+

BarretR2 Cloud+

BarretR2 Snapshot

BarretR2 Cloud+

BarretR2 Cloud+

BarretR2 Cloud+

BarretR2 Cloud+

BarretR2 Snapshot

BarretR2 Snapshot

1 2 3 5

E

22'-10" 22'-10" 22'-10" 22'-11"

'-5

1' -9

/2

1'

-9

/2

1'-9 1/2" 1'-9 1/2"

10" CONC SLAB

W/ #6@12 EW

(T & B)

B

C

D

A

'-2

/2

'-0

'-0

'-2

/2

1'-7 1/2"

B.2

C.74' -8

/2

3'

-1

'-2

/2

FOR CURB,

SEE CIVIL

SHT

1'-7 1/2"

1'-7 1/2"

W8x31

COLUMN

(TYP UN)

91'-5"

RECESSED LOADING

DOCK, 3 PLA

E

B

D

A

7'-3" HSS 8x3 POST FOR

MOVEABLE PARTITION

7'-3"

6' -2

3'

-1 1"

3' -1

1" 6'

-2

3' -1

1" 3'

-1 1"

6' -2

'-2

/2

'-2

/2

FD

FD

EQ

VERT

BRACING

(TYP)

S-302

LADDER UP TO

EL 117'-8 3/4"

C

S-301

S-301

S-301

S-301

S-301

S-301

S-201

B

S-202D

S-201 A

S-202

C

S-302

S-302

LA

D

D

ER

FD

'-0

2' -0

2'

-0

'-0

2' -0

2'

-0

'-0

3'

-2

/2

1'-0 1/8" TO

C8 FACE

C8x11.5 ROLL-UP DOOR

POST (TYP 6 PLA)

W10x68 COL

W10x68 COL

W10x68 COL

W10x68 COL

W10x68

COL

1/8"=1'-0" 16'8'4'0

FIRST FLOOR SLAB PLAN

- TOP OF 10" SLAB EL 100'-0" (DATUM)

- DIMENSIONS TO BE COORDINATED WITH ACTUAL

EQUIPMENT PURCHASED AND WITH ARCH SHEETS

- L-X DENOTES STEEL ANGLE LINTEL, SEE STEEL LINTEL &

BEARING PLATE SCHEDULE ON S-505.

- FIRST FLOOR SLAB IS A STRUCTURAL DIAPHRAGM AND

PART OF THE SEISMIC FORCE RESISTING SYSTEM.

SAWCUTTING FOR FUTURE UNSPECIFIED WORK IS NOT

PERMITTED WITHOUT DETAILED ANALYSIS BY A

PROFESSIONAL ENGINEER.

- SEE SHEET S-101 FOR ADDITIONAL PILE LOCATING

NOTES.

TYP

S-301

FOR SUPPLEMENTAL

RE-ENTRANT CORNER BARS

SEE DETAIL ON SHT S-501

2' -0

FOR RAMP RETAINING

WALLS, SEE S-101 FOR

ADDITIONAL INFORMATION

4' -6

/2

SEE ENLARGED

PLAN SHEET S-401

3'-8"

TOP OF LANDING

EL 100'-0"

3' -0

AC

C

ES

S

PA

N

EL

SLAB OPNG FOR

MECHANICAL DUCT,

COORD OPNG SIZE WITH

MECH CONTRACTOR

(3)-#6 @ 12 TOP & BOT REINFORCING

IN ADDITION TO THE TYPICAL FLOOR

SLAB REINFORCING, TYP 3-SIDES OF

RECESSED LOADING DOCKS

L- X

TOP OF CONC

PAD EL 95'-4"

S-301

S-301

MASONRY WALL,

SEE ARCH

TYP 4-PLA

2'-9"

FLOOD VENT

2'-9"

FLOOD VENT

2'-9"

FLOOD VENT

2'-9"

FLOOD VENT

2'-9"

FLOOD VENT

2'-9"

FLOOD VENT

* * *2'-9"

FLOOD VENT*

5"± SLAB DEPRESSION AT ELEC FLOOR

BOX, TYP 21-PLA, COORD FLOOR BOX

LOCATIONS WITH ELEC CONTRACTOR

COORD PLACEMENT

OF REBAR WITH FLOOR

BOX LOCATIONS

ADD'L REINF AT CORNERS

OF SLAB DEPRESSION, SEE

TYPICAL DETAIL ON S-501

2'-9"

FLOOD VENT

TYP

S-301

SLOPE

SLOPE

SLOPE

ADD'L REINF AT CORNERS

OF SLAB OPENING, SEE

TYPICAL DETAIL ON S-501

S-301

TYP 4-PLA

ADD'L 2-#6 x 8'-0"

LONG TOP BARS

EW (TYP EA PIER)

ADD'L 2-#6 x 20'-0"

LONG BOT BARS AT

CMU WALL LOCATION

2'-4 1/4"

3/

8" 1'

-2

1'-2"

ADD'L 3-#6 x 12'-0" LONG TOP BARS

ADD'L 3-#6 x 12'-0" LONG TOP BARS

ADD'L 3-#6 x 8'-0" LONG TOP BARS ADD'L 3-#6 x 8'-0" LONG TOP BARSADD'L 3-#6 x 8'-0" LONG TOP BARS

1 5/8"

1' -2

" W

AL

L

7' -0

/2

1' -2

" W

AL

L

CONC PAVEMENT,

SEE CIVIL SHTS

SIGN, SEE

CIVIL SHTS

RAMP, SEE

CIVIL SHTS

40'-0"

5'-0"

3' -0

EQ

S

PA

'-0

6' -0

18" CONC SLAB

W/ #6@12 EW

(T & B)

S-304

S-304

S-304

9'-1 1/2"3'-0"

IN

N

ER

L

AY

ER

OUTTER LAYER

S-301

'-0

3' -0

1/

2"

S-304

11'-4 1/2" 11'-6"

(3) ADDITIONAL #6x6'-0" TOP

BARS EW @ 12" CENTERED

OVER TOP OF PRECAST

PILE (TYP @ EA PILE)

RECESSED AREA, DROP TOP REBAR

DOWN AT SLAB DEPRESSION TO

MAINTAIN CONC COVER, SEE

INTERIORS DRAWINGS FOR EXTENT

OF SLAB DEPRESSION REQUIRED

5/8"5/ 8"

15'-10"

6' -0

C

GENERAL SHEET NOTES

1. FOR GENERAL STRUCTURAL NOTES, SEE SHEETS S-001 & S-002.

2. FOR TYPICAL CONCRETE DETAILS, SEE SHEETS S-501 & S-502.

3. FOR COLUMN SCHEDULE, BASE PLATE AND ANCHOR ROD

DETAILS, SEE SHEET S-505.

4. FOR TYPICAL MASONRY DETAILS, SEE SHEET S-506.

DRAWING SCALES SHOWN BASED ON 22"x34" DRAWING

DE

PA

RT

M

EN

T

OF

H

OM

EL

AN

D

SE

CU

RI

TY

FE

DE

RA

L

LA

W

E

NF

OR

CE

M

EN

T

TR

AI

NI

NG

C

EN

TE

R

CU

ST

OM

S

BO

RD

ER

P

AT

RO

L

B

AI

NB

RI

DG

E

AV

E, C

HA

RL

ES

TO

N, S C

Sheet Reference No.

1:

(D S

H

EE

T)

SEAL

R W

B

D w n by

D es ig ne d by

R ev ie w ed b y:

D at e:

R ev

C kd b y:

Su bm itt ed b y:

D ra w in g Sc al e:

Pl ot s ca le

ST

V

Pr oj ec t N o.

D ra w in g co de

D es cr ip tio n

D at e Ap pr

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

M ar k

9/ 8/

ST

V

In co rp or at ed

W

ES

T W

EL

SH

D R

IV

E

D O

U G

LA

SS

VI

LL

E, P

A

D

.0

CA

RG

O

SE

CU

RI

TY

A

ND

S

EI

ZE

D

PR

OP

ER

TY

T

RA

IN

IN

G

FA

CI

LT

Y

Fi le

I:\

Pr oj ec ts

\D

.0

\D

.0

_0

1\

_C

AD

M od el s an d

Sh ee ts \0

6_ S_

St ru ct ur al \C

SS

PT

F\ S-

; P lo tte d:

0/

/2

5:

P M b y

D O

U G

LA

S

BE

AM

; S av ed

/1

2/

:3

PM

INDEX: OF

S-102

FI

R

ST

F

LO

O

R S

LA

B

P

LA

N

D

EB

D

EB

D

EB

JY

C

A

FI

NA

L S

UB

MI

TT

AL

/10

/26

RW

B B

RT

A

/08

/26

RW

B C

RE

VI

SE

D

PE

R

AM

EN

DM

EN

T

/13 /26

RW

B

P F

T

T T

T

T T

T

T

T

TT

T

T

D

C

B

1 2 4 5

20x12

16ø ø ø

G-1

G-1

D-1

D-2

G-2

D-1

G-1

D-1

G-1

G-1

D-1

R-1

R-1

R-1

75G-1

D-1

D-4

F

R-2

22x22 20x12

G-1

BD

BD

BDBD

BD

BD

BD

BD

BD

BDBDBD BD

BD

8ø

14x14 x

10x10

12x10 x

12x6

10x10 D-1

6x6

6x6

6x6

10x10

DL-1

DL-1

DL-1

DL-1

DL-1

DL-1

DL-1

DL-1

8ø

10x10

6ø

6ø

18x14

EXHAUST UP

EV-1 ON ROOF

D-4

D-4

BDBD

BDBD

BDBD

BDBD

R-3

12x12

8x8

6ø

6ø

BD

BDBD

6x6

8x8 6x6 6x6

BD

BD

BD

10x10

8x8

8x8

14x14 HC

M-301

M-301

FD FD

FDFD

12x12

12x12

8x8

FD

FD

CP

12x10

12x10

12x6

20x12

8ø

BD

BD

BD

DAC-11

DAC-12

DAC-4

DAC-9

DAC-10

DAC-8

DAC-7

DAC-6

DAC-3

DAC-2

DAC-1

DAC-5

D

D

D D

D

D D

D D

D

D

DD

D

DDD

1"ø

1"ø

1"ø

1"ø

1"ø

1"ø

1"ø

1"ø

1"ø 1"ø

1"ø

1"ø

1"ø1"ø

18x14

18x14

6ø x x

14x14

FDFD

FD

FD

FD

14x18

M-301

8x8

1"ø

1"ø

18x14

MD

30x20 LOUVER, SEE

ARCHITECTURAL

SHEETS

1"ø

D

FD

20x1216ø

ADR

ADR

ADR

ADRADR

ADR

ADR

10x10

FD

ADR

SLOPE

S L O

P E

SLOPE

SLOPE

SLOPESLOPE

S L O

P E

S L O

P E

F-1

1 1

3 6

M-301

M-301

M-301

INSPECTION

VEST

V-01

BREAK AREA

HIGH RISK VAULT

GEN PROP VAULT

EVIDENCE PROC

AND PREP

MECH / ELEC /

PLUMB

AG INSPECTION

PROP STOR

INST A/V

LAN

MEN'S TOILET

WOMEN'S TOILET

JC

CLASSROOM A

CLASSROOM B

CORRIDOR

C-01

SA

SA

x

PPE GOWNING

M-301

E

A

ADR

ADR

ADR

BD

D-1

BD

6ø

DAC

DAC

DAC

DAC

DAC

DAC

DAC

DAC

DAC

DAC

DAC

DAC

30x20

ERU

1"ø

FCU

8x8

18x14

FDADR

DRAWING SCALES SHOWN BASED ON 22"x34" DRAWING

D E

P A

R T

M E

N T

O F

H O

M E

LA

N

D S

E C

U R

IT

Y

F E

D E

R A

L

LA

W E

N F

O R

C E

M E

N T

T R

A

IN

IN

G

C E

N T

E R

C U

S T

O M

S

B O

R D

E R

P A

T R

O L

C A

R G

O S

E C

U R

IT

Y

A N

D S

E

IZ

E D

P R

O P

E R

T Y

T R

A

IN

IN

G

F A

C

IL

IT

Y

B A

IN

B

R

ID

G E

A V

E , N

O R

T H

C H

A R

LE

S

T O

N , S

C

Sheet Reference No.

:1

D

S H

E E

T

D .0

SEAL

R W

B

D w n b y

D e s ig n e d b y

R e v ie w e d b y

D a te

R e v

C k d b y

S u b m it te d b y

D ra w in g S c a le

P lo t s c a le

S T

V P ro je c t

N o

D ra w in g c o d e

D e s c ri p ti o n

D a te

A p p r.

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

M a rk

INDEX: OF

13B1193.51AKEYPLANSCALE: NONE

S T

V I n c o rp o ra te d

W

E S

T W

E L S

H D

R

IV

E D

O U

G L A

S S

V

IL

L E

P

A

C

C U s e rs \m o s e rw r\ D o c u m e n ts

\M -D

-C S

S P

T F

-2 m o s e rw r.

rv t

/1 /2

:1

:2

A M

F L

O O

R P

L A

N

/1

/2

W

R M

W R

M M

B L

A R

M-101

GENERAL SHEET NOTES

SHEET KEYNOTES

1. SEE SHEET M-001 FOR GENERAL NOTES AND LEGEND.

1. FIELD ROUTE RS & RL PIPING BETWEEN HEAT PUMP ON

ROOF AND DUCTLESS AIR CONDITIONING UNITS ABOVE

CEILING. SIZE ALL PIPING AS PER MANUFACTURERS

INSTALLATION INSTRUCTIONS. ROUTE PIPING AS HIGH AS

POSSIBLE IN CEILING SPACE TO TERMINATION

POINTS.

2. FIRE SEAL WALL PENETRATION FOR 1.5 HOUR FIRE

RATING.

3. BALANCE VENTILATION AIR FOR INSPECTION ROOM 100 TO

275 CFM.

4. TERMINATE CONDENSATE DRAIN AT FLOOR DRAIN IN

MECHANICAL ROOM 108.

5. TERMINATE CONDENSATE DRAIN AT MOP SINK IN JANITORS

CLOSET 115.

6. COORDINATE IN FIELD CROSSING THROUGH STRUCTURAL

CROSS BRACING AT THIS POINT.

7. 10x10 ALUMINUM DUCTWORK FROM EF-1 ON ROOF TO OPEN ENDED DUCT W/ 1/4"x1/4" WIRE MESH SCREEN IN CRAWL

SPACE. DUCTWORK SHALL BE SEALED WEATHERTITE

ALONG THE ENTIRETY OF THE VERTICAL RUN. SEAL

DUCTWORK PENETRATION THROUGH SLAB WEATHER /

WATER TITE.

8. VFD SERVING EF-1 MOUNTED ON WALL.

9. ERU-1 ELECTRIC CONTROL BOX MUST BE MOUNTED ON

THIS SIDE OF UNIT. MAINTAIN 36" CLEAR IN FRONT OF PANEL

PER NEC.

3/16" = 1'-0"

FLOOR PLAN

4' 12'0 8'

A F

IN

A

L D

E S

IG

N

/1

/2

R W

B

B R

T A

/0

/2

R W

B

C R

E V

IS

E

D P

E R

A M

E N

D M

E N

T

/1

/2

R W

B

C

C

SERVICE PRESSURE CLASS

DUCTWORK PRESSURE/SEAL CLASS

SYSTEM

SUPPLY

FCU-1

EF-1

RETURN

+1"

-1"

+2"

A

A

A

-1" AEXHAUST

-2" A

SUPPLY

OUTSIDE AIRERU-1

EXHAUST AIR -2" A

SEAL

CLASS

ENERGY RECOVERY UNIT SCHEDULE

MARK

BASIS OF

DESIGN

MODEL

SUPPLY FAN

NOTES

HEAT PUMP SCHEDULE

BASIS OF

DESIGN

MFR

EXHAUST FAN

CFM RPM

DISCHARGE

ARRANGEMENT

ESP

(IN.WG.)

VOLTS PHASE Hz HP FLA CFM RPM

DISCHARGE

ARRANGEMENT

ESP

(IN.WG.)

VOLTS PHASE Hz HP FLA

ERU-1 OXYGEN 8 NOVA B20 1185 2428 HORIZONTAL 1.0 208 1 60 1.0 3.9 1185 2447 HORIZONTAL 1.0 208 1 60 1.0 3.9

ENERGY RECOVERY UNIT SCHEDULE (CONTINUED)

OUTDOOR AIR RETURN AIR SUPPLY AIR EXHAUST AIR

MIN

RECOVERY

EFF

SENS. / LAT.

TYPE

ELECTRICAL (UNIT)

ELECTRICAL

(CONTROLLER)

EECTRICAL (ELECTRIC

REHEAT)

CFM

AIR TEMP °F

CFM

AIR TEMP °F

CFM

MAX

PD IN

WG

AIR TEMP °F

CFM

MAX

PD IN

WG

AIR TEMP °F

V/PH/HZ MCA MOCP V/PH/HZ MCA MOCP V/PH/HZ MCA MOCP

SUMMER WINTER SUMMER WINTER SUMMER WINTER SUMMER WINTER

1185 91 19 1185 75 70 1185 0.43 81.2 50.1 1185 0.97 84.8 38.9 60.9 / 45.6 ROTARY 208/1/60 8.8 15 208/1/60 0.3 15 208/1/60 42.08 45 -

HEATING AND COOLING UNIT SCHEDULE

MARK MFR MODEL CFM

COOLING COIL HEATING COIL

MATCHED

OUTDOOR -

#UNIT

NOTESEAT °F LAT °F

TOTAL

MBH

SENSIBLE

MBH

REFRIGERANT

EAT° F LAT° F

TOTAL

KW

NO. OF

STAGES

VOLTS PHASE Hz

DB WB DB WB

SUCTION

TEMP °F

TYPE

HC-1 OXYGEN 8 3EN1405A 1185 81.2 70.7 57.0 56.0 66.8 36.5 43 R32 55 70 4.8 1 208 1 60 HP-5 -

ELECTRONIC EXPANSION VALVE BOX SCHEDULE

MARK

BASIS OF

DESIGN

MFR

BASIS OF

DESIGN

MODEL

NOMINAL

CAPACITY

(MBH)

AHU HEAT

EXCHANGER

COOLING

CAPACITY RANGE

(MBH)

AHU HEAT

EXCHANGER

HEATING

CAPACITY RANGE

(MBH)

AHU HEAT

EXCHANGER

REFRIGERANT

VOLUME RANGE

(CUBIC INCHES)

ELECTRIC

MATCHED

INDOOR

#UNIT

MATCHED

OUTDOOR

UNIT#

NOTES

VOLTS PHASE Hz

EEV-1 DAIKIN EKEXV140-US 60.0 53.0 - 60.0 59.5 - 67.5 252 - 281 208 1 60 HC-1 HP-5 -

MARK

BASIS

OF

DESIGN

MFR

BASIS OF

DESIGN MODEL

NOMINAL

COOLING TOTAL

BTU/HR

NOMINAL

HEATING TOTAL

CAP. BTU/HR

COOLING

OPERATION

TEMP °F

REFRIGERANT

TYPE

COMPRESSOR

VOLTS PHASE Hz MCA MOCP

MIN.

ENERGY

EFF

(SEER2)

MATCHED

INDOOR # UNIT(S)

NOTES

RLA TYPE

HP-1 DAIKIN RXTA60AAVJU 57500 57000 95 R32 23.2 INVERTER 208 1 60 34.6 35 16 FCU-1 -

HP-2 DAIKIN RXTA48AAVJU 45500 47500 95 R32 19.0 INVERTER 208 1 60 29.4 30 20.5

DAC-1, DAC-2, DAC-3,

DAC-5, DAC-11, DAC-12

HP-3 DAIKIN RXTA36AAVJU 34200 37000 95 R32 15.3 INVERTER 208 1 60 19.8 20 20 DAC-6, DAC-7, DAC-8 -

HP-4 DAIKIN RXTA48AAVJU 45500 47500 95 R32 19.0 INVERTER 208 1 60 29.4 30 23 DAC-9, DAC-10 -

HP-5 DAIKIN RXTA60AAVJU 57500 57000 95 R32 23.2 INVERTER 208 1 60 34.6 35 20 HC-1 -

CONDENSING UNIT SCHEDULE

MARK

BASIS

OF

DESIGN

MFR

BASIS OF

DESIGN

MODEL

CONDENSER FAN DATA COMPRESSOR DATA ELECTRICAL DATA

MATCHED

INDOOR # UNIT NOTES

QUANTITY

TOTAL

CFM

TOTAL

WATTS

QUANTITY RLA

NOMINAL

TONS

REFRIGERATION

TYPE

VOLTS Hz PHASE

CU-1 DAIKIN RKF12BVJU9 1 730 41 1 7.5 1.0 R32 208 60 1 DAC-4 -

DRAWING SCALES SHOWN BASED ON 22"x34" DRAWING

D E

P A

R T

M E

N T

O F

H O

M E

LA

N

D S

E C

U R

IT

Y

F E

D E

R A

L

LA

W E

N F

O R

C E

M E

N T

T R

A

IN

IN

G

C E

N T

E R

C U

S T

O M

S

B O

R D

E R

P A

T R

O L

C A

R G

O S

E C

U R

IT

Y

A N

D S

E

IZ

E D

P R

O P

E R

T Y

T R

A

IN

IN

G

F A

C

IL

IT

Y

B A

IN

B

R

ID

G E

A V

E , N

O R

T H

C H

A R

LE

S

T O

N , S

C

Sheet Reference No.

:1

D

S H

E E

T

D

.0

SEAL

R W

B

D w n b y

D e s ig n e d b y

R e v ie w e d b y

D a te

R e v

C k d b y

S u b m it te d b y

D ra w in g S c a le

P lo t s c a le

S T

V P ro je c t

N o

D ra w in g c o d e

D e s c ri p ti o n

D a te

A p p r.

E

21 3 4 5 6

D

C

B

A

21 3 4 5 6

E

D

C

B

A

M a rk

INDEX: OF

13B1193.51AKEYPLANSCALE: NONE

S T

V I n c o rp o ra te d

W

E S

T W

E L S

H D

R

IV

E D

O U

G L A

S S

V

IL

L E

P

A

C

C U s e rs \m o s e rw r\ D o c u m e n ts

\M -D

-C S

S P

T F

-2 m o s e rw r.

rv t

/1 /2

:1

:2

A M

S C

H E

D U

L E

S

/1

/2

W R

M

W R

M M

B L

A R

M-701

GENERAL SHEET NOTES

1. SEE SHEET M-001 FOR GENERAL NOTES AND LEGEND.

A F

IN

A

L D

E S

IG

N

/1

/2

R W

B

B R

T A

/0

/2

R W

B

C R

E V

IS

E

D P

E R

A M

E N

D M

E N

T

/1

/2

R W

B

G-001 COVER SHEET
G-002 SHEET INDEX
STRUCTURAL
S-102 - First Floor Plan
G-002 SHEET INDEX
MECHANICAL
M-101 - First Floor Plan
M-701 - Schedules