260424 - Forest Hills Nature Center - Bid set - Civil.pdf
PDF 1 MB Posted
- Attached to
- Forest Hill Nature Center - New Building
- Solicitation number
- RFP GIR 260000001926 5
- Issued by
- Ingham County, Huntington Woods City, Michigan
About this file
This is a civil engineering bid set document for the Forest Hills Nature Center New Building project located at 1297 N Rich Road in Alma, Michigan 48801, within Seville Township, Gratiot County. The document contains detailed technical specifications and construction drawings for the facility's mechanical and civil infrastructure systems. Key project components include a duplex sump pump station with redundant high water alarms and alternating pump operation controls, a septic tank system designed per AASHTO 17th Edition and ASTM specifications with H-25 loading capacity, a drain field with 40-foot width, sanitary cleanout details, and a rock riprap dissipator. The specifications require Schedule 80 PVC pipe with tracer wire and warning tape for force mains, perforated HDPE N12 pipe for cooling tower drainage, 5000 PSI concrete reinforcement per ASTM standards, and KOR-N-SEAL sealant. All technical drawings are provided at various scales with detailed elevation and dimension specifications for proper installation and operation.
The document specifies that contractors are responsible for providing and installing all control systems necessary to meet the sequence of operations for the pump station, which includes five operational levels triggered by water level alarms. Pipe and fittings for inlets and outlets are noted as not included in the septic tank specifications. The septic tank and drain field design criteria are based on Mid-Michigan Health Department standards. Material specifications reference MDOT 6A standards and require adherence to manufacturer specifications for tie-downs and equipment installation. The project drawings are dated 24-0569 and prepared by Matrix, indicating this is a professional engineering design package for competitive bidding purposes.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C-4
GENERAL NOTES
1. PIPE/ FORCE MAIN - SCHEDULE 80 PVC WITH
TRACER WIRE AND WARNING TAPE.
2. COOLING TOWER DRAIN - PERFORATED HDPE
N12 PIPE.
EXISTING LEGEND
-4
F o re st
H il ls N a tu re C en te r N ew N a tu re C en te r N
R ic h R d A lm a
M I
S ev il le
T o w n sh ip , G ra ti o t
C o u n ty
A lm a , M ic h ig a n 4
M A
T R
I X
C-400
BASIN COVER
BASIN
NON-SLAM
(TYPICAL)
CHECK VALVE
2"
GATE VALVE
LEVEL 4: PUMP 2 (LAG)
'ON' HIGH WATER ALARM
2"-OUTLET AS
NOTED ON PLANS
LEVEL 5: REDUNDANT
HIGH WATER ALARM
GAS TIGHT COVER
EXISTING GRADE
BASIN (60"Øx112" DEEP)
DISCHARGE PIPE
PUMP CASE
VOLUTE
LEVEL 1: LOW WATER ALARM
NOTE:
WATER LEVEL MINIMUM 1'-6" ABOVE PUMP
CASE
PROVIDE TIE DOWNS PER THE
MANUFACTURER'S WRITTEN SPECIFICATIONS.
4' 6"
6" 1'-
6"
SUPPORT POLE
6'x6' CONCRETE PAD
#4 REBAR 8" O.C.
EACH DIRECTION
GATE VALVE
2"
3'- 9"
LEVEL 3: PUMP 1 'ON'
LEVEL 2: PUMPS 'OFF'
FF ELEV. = 815.27
2"
2' 6"
4" SAN
812.00
PUMP STATION SEQUENCE OF OPERATION:
- LEVEL 1 - LOW WATER ALARM
- LEVEL 2 - BOTH PUMPS 'OFF'
- LEVEL 3 - START LEAD PUMP; PUMPS SHALL
ALTERNATE ON EACH CALL
- LEVEL 4 - START LAG PUMP; BOTH PUMPS
RUNNING SIMULTANEOUSLY; HIGH WATER
ALARM
- LEVEL 5 - REDUNDANT HIGH WATER LEVEL
ALARM
*CONTRACTOR IS RESPONSIBLE FOR PROVIDING
AND INSTALLING ALL CONTROLS ON THE BUILDING
AS NEEDED TO MEET THE SEQUENCE OF
OPERATIONS.
LIFT STATION
4D
2.5D
1D
D FLOW
1D
8"
24"
PVC FEMALE CLEANOUT ADAPTER WITH
INVERTED NUT SCREW CAP OR FLAT SLOTTED
SCREW CAP
PVC PIPE
45° BEND
SEWER LATERAL
E.J.I.W. 1040 M3 MANHOLE FRAME LID
INSTALLED FLUSH WITH FINISHED SURFACE
EXISTING GRADE
CONCRETE COLLAR POURED AROUND
CLEANOUT COVER (3,500 PSI)
KOR-N-SEAL NO. S406-10 AWS*
6"x6" TWO-WAY TEE
SEWER LATERAL
45° BEND
SEWER
TOP ELEVATION
4"
6"6" 10'-8-1/2" 11'-8-1/2"
6'- 0-
1/4
PVC SCHEDULE
40 BY OTHERS
5'- 6-
1/2
11'-8-1/2"
4"
4"x24" OPENING
7K KOR-N-SEAL
FOR 4" PVC
TYP-(2) PLACES
24" ACCESS (ABOVE)
TYP-(2) PLACES
7'-2-1/2" 3'-6"
5"x1" KEYWAY
TYP-(3) SIDES
CAULK ALL AROUND
TYP- BOTH SIDES
4'- 0-
1/4
2'- 0"
6"
4'-
-1 /4"
7"
5'-6-1/2" 4'-6-1/2"6" 6"
56"
CASTING & ADJUSTMENT TO
FINISH GRADE NOT INCLUDED
NOTES:
SEPTIC TANK SECTIONS TO BE MANUFACTURED PER AASHTO 17TH ED. AND
ASTM SPECIFICATIONS W/H-25 LOADING AND 0.0' TO 3.0' OF EARTH COVER.
CONCRETE: 5000 PSI @ 28 DAYS
REINFORCEMENT PER ASTM A-615 & A-496
COVER TO BE SEALED W/1-1/2" EZ-STIK OR EQUAL
PIPE AND FITTINGS FOR INLETS & OUTLETS ARE NOT INCLUDED
4" I.E.=814.80
I.E.=814.90
RIM ELEV. = 818.40 RIM ELEV. = 818.20
6'x6' CONCRETE PAD
12" 12"6"
6" OVERFILL
4" PERF.
PVC, TYP. 5 MDOT 6A
DRAIN FIELD WIDTH - 40'
NOTE: SEPTIC TANK AND DRAINFIELD DETAILS AND DESIGN
CRITERIA BASED ON THE MID-MICHIGAN HEALTH DEPARTMENT
4' 3'
18"
C-800
-4
F o re st
H il ls N a tu re C en te r N ew N a tu re C en te r
N
R ic h R d
A lm a M
I
S ev il le
T o w n sh ip
, G ra ti o t C o u n ty
A lm a , M ic h ig a n 4
M A
T R
I X
2 ROCK RIPRAP DISSIPATOR
SCALE: NTS
3 DOUBLE SANITARY CLEANOUT DETAIL
SCALE: NTS1 SUMP PUMP DUPLEX DETAIL
SCALE: NTS
4 SEPTIC TANK DETAIL
SCALE: NTS
1 DRAIN FIELD SECTION VIEW
SCALE: NTS
| 24-0569 TOPO_PRELIMINARY-new-Layout1-Ttlb 30x42 |
| C800-25034900-Layout1 |