260424 - Forest Hills Nature Center - Bid set - Civil.pdf
PDF 1 MB Posted
- Attached to
- Forest Hill Nature Center - New Building
- Solicitation number
- RFP GIR 260000001926 3
- Issued by
- Ingham County, Michigan
About this file
This is a civil engineering bid set document for the Forest Hills Nature Center New Building project located at 1297 N Rich Road, Alma, Michigan 48801, in Seville Township, Gratiot County. The document provides detailed technical specifications and construction drawings for critical infrastructure components including a duplex sump pump lift station with dual pump redundancy, a sanitary sewer system with cleanout details, a septic tank system designed for H-25 loading with 0.0' to 3.0' earth cover, and a drain field measuring 40' in width. The sump pump station includes five operational levels with low water alarms, pump sequencing controls, and high water alarms, with both pumps capable of running simultaneously. All piping specifications call for Schedule 80 PVC with tracer wire and warning tape for force mains, and perforated HDPE N12 pipe for cooling tower drains. The septic tank and drain field design comply with Mid-Michigan Health Department criteria and are manufactured per AASHTO 17th Edition and ASTM specifications.
The specifications detail concrete pad requirements of 6'x6' with #4 rebar at 8" on-center spacing in each direction, 5000 PSI concrete at 28 days, and pipe and fitting materials meeting ASTM A-615 and A-496 standards. Tank covers must be sealed with 1-1/2" EZ-STIK or equivalent material. The document notes that pipe and fittings for inlets and outlets are not included in the specified scope, casting and adjustment to finish grade are not included, and the contractor is responsible for providing and installing all building controls necessary to meet the specified sequence of operations. The project reflects municipal infrastructure requirements for a nature center facility in Michigan.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C-4
GENERAL NOTES
1. PIPE/ FORCE MAIN - SCHEDULE 80 PVC WITH
TRACER WIRE AND WARNING TAPE.
2. COOLING TOWER DRAIN - PERFORATED HDPE
N12 PIPE.
EXISTING LEGEND
-4
F o re st
H il ls N a tu re C en te r N ew N a tu re C en te r N
R ic h R d A lm a
M I
S ev il le
T o w n sh ip , G ra ti o t
C o u n ty
A lm a , M ic h ig a n 4
M A
T R
I X
C-400
BASIN COVER
BASIN
NON-SLAM
(TYPICAL)
CHECK VALVE
2"
GATE VALVE
LEVEL 4: PUMP 2 (LAG)
'ON' HIGH WATER ALARM
2"-OUTLET AS
NOTED ON PLANS
LEVEL 5: REDUNDANT
HIGH WATER ALARM
GAS TIGHT COVER
EXISTING GRADE
BASIN (60"Øx112" DEEP)
DISCHARGE PIPE
PUMP CASE
VOLUTE
LEVEL 1: LOW WATER ALARM
NOTE:
WATER LEVEL MINIMUM 1'-6" ABOVE PUMP
CASE
PROVIDE TIE DOWNS PER THE
MANUFACTURER'S WRITTEN SPECIFICATIONS.
4' 6"
6" 1'-
6"
SUPPORT POLE
6'x6' CONCRETE PAD
#4 REBAR 8" O.C.
EACH DIRECTION
GATE VALVE
2"
3'- 9"
LEVEL 3: PUMP 1 'ON'
LEVEL 2: PUMPS 'OFF'
FF ELEV. = 815.27
2"
2' 6"
4" SAN
812.00
PUMP STATION SEQUENCE OF OPERATION:
- LEVEL 1 - LOW WATER ALARM
- LEVEL 2 - BOTH PUMPS 'OFF'
- LEVEL 3 - START LEAD PUMP; PUMPS SHALL
ALTERNATE ON EACH CALL
- LEVEL 4 - START LAG PUMP; BOTH PUMPS
RUNNING SIMULTANEOUSLY; HIGH WATER
ALARM
- LEVEL 5 - REDUNDANT HIGH WATER LEVEL
ALARM
*CONTRACTOR IS RESPONSIBLE FOR PROVIDING
AND INSTALLING ALL CONTROLS ON THE BUILDING
AS NEEDED TO MEET THE SEQUENCE OF
OPERATIONS.
LIFT STATION
4D
2.5D
1D
D FLOW
1D
8"
24"
PVC FEMALE CLEANOUT ADAPTER WITH
INVERTED NUT SCREW CAP OR FLAT SLOTTED
SCREW CAP
PVC PIPE
45° BEND
SEWER LATERAL
E.J.I.W. 1040 M3 MANHOLE FRAME LID
INSTALLED FLUSH WITH FINISHED SURFACE
EXISTING GRADE
CONCRETE COLLAR POURED AROUND
CLEANOUT COVER (3,500 PSI)
KOR-N-SEAL NO. S406-10 AWS*
6"x6" TWO-WAY TEE
SEWER LATERAL
45° BEND
SEWER
TOP ELEVATION
4"
6"6" 10'-8-1/2" 11'-8-1/2"
6'- 0-
1/4
PVC SCHEDULE
40 BY OTHERS
5'- 6-
1/2
11'-8-1/2"
4"
4"x24" OPENING
7K KOR-N-SEAL
FOR 4" PVC
TYP-(2) PLACES
24" ACCESS (ABOVE)
TYP-(2) PLACES
7'-2-1/2" 3'-6"
5"x1" KEYWAY
TYP-(3) SIDES
CAULK ALL AROUND
TYP- BOTH SIDES
4'- 0-
1/4
2'- 0"
6"
4'-
-1 /4"
7"
5'-6-1/2" 4'-6-1/2"6" 6"
56"
CASTING & ADJUSTMENT TO
FINISH GRADE NOT INCLUDED
NOTES:
SEPTIC TANK SECTIONS TO BE MANUFACTURED PER AASHTO 17TH ED. AND
ASTM SPECIFICATIONS W/H-25 LOADING AND 0.0' TO 3.0' OF EARTH COVER.
CONCRETE: 5000 PSI @ 28 DAYS
REINFORCEMENT PER ASTM A-615 & A-496
COVER TO BE SEALED W/1-1/2" EZ-STIK OR EQUAL
PIPE AND FITTINGS FOR INLETS & OUTLETS ARE NOT INCLUDED
4" I.E.=814.80
I.E.=814.90
RIM ELEV. = 818.40 RIM ELEV. = 818.20
6'x6' CONCRETE PAD
12" 12"6"
6" OVERFILL
4" PERF.
PVC, TYP. 5 MDOT 6A
DRAIN FIELD WIDTH - 40'
NOTE: SEPTIC TANK AND DRAINFIELD DETAILS AND DESIGN
CRITERIA BASED ON THE MID-MICHIGAN HEALTH DEPARTMENT
4' 3'
18"
C-800
-4
F o re st
H il ls N a tu re C en te r N ew N a tu re C en te r
N
R ic h R d
A lm a M
I
S ev il le
T o w n sh ip
, G ra ti o t C o u n ty
A lm a , M ic h ig a n 4
M A
T R
I X
2 ROCK RIPRAP DISSIPATOR
SCALE: NTS
3 DOUBLE SANITARY CLEANOUT DETAIL
SCALE: NTS1 SUMP PUMP DUPLEX DETAIL
SCALE: NTS
4 SEPTIC TANK DETAIL
SCALE: NTS
1 DRAIN FIELD SECTION VIEW
SCALE: NTS