2601_OC_Facilities_Warehouse_Syst_FOR_BID_(26.09.15).pdf
PDF 909 KB Posted
- Attached to
- Facilities & Parks New Supply Warehouse Building
- Solicitation number
- ITB FM 04-27
- Issued by
- Okaloosa County, Florida
About this file
Facilities & Parks New Supply Warehouse Building - Telecommunications and Security Systems Design
This file contains comprehensive technical drawings and specifications for telecommunications, access control, and IP security camera systems for the Okaloosa County, Florida Facilities & Parks New Supply Warehouse Building located at 5489 Old Bethel Road, Crestview, Florida 32536. The project, prepared by HG Engineers (Project No. 26004 with authorization no. 00006680), specifies the installation of structured cabling infrastructure including Category 6A horizontal wiring with 48-port and 24-port modular patch panels, a wall-mounted communications rack equipped with network switch, UPS system, fiber optic connectivity, and wireless access point installations throughout the warehouse facility. The telecommunications system design accommodates data, voice, and security camera communications, with cable routing requirements in three-quarter-inch and two-inch conduit, grounding systems, and cable management provisions. The access control system design includes seven secured doors (101C, 101D, 102C, 102F, 102G, 105A, 105B) with electrified locksets, card readers, door position switches, and request-to-exit devices integrated with a central access control panel located in the mechanical/electrical room (Space 109). The IP security camera system specifies multiple i-PRO camera models for indoor and outdoor surveillance, including 360-degree and 270-degree multiview cameras, with network video recording capabilities featuring RAID 5 or 6 storage, H.265/H.264 codec, and minimum 30-day archival capacity at full resolution.
The design documents establish specific material standards requiring Belden cable and connectors, Chatsworth equipment racks, Panduit cable management products, and i-PRO security cameras, with detailed installation requirements for conduit routing, cable slack provisions, grounding, firestopping, and labeling protocols. All telecommunications cabling shall maintain minimum clearances of 8 inches from 120-volt electrical wiring and 12 inches from motors and light fixtures, with a maximum of two 90-degree bends in conduit runs before requiring a pullbox. The contractor is responsible for field coordination with other trades, verification of final conduit routing and outlet locations prior to rough-in, and compliance with the National Electrical Code and local fire-rating requirements. Cable installation specifications define maximum horizontal wiring lengths of 90 meters (295 feet) for Category 6A and Category 6 cables, with equipment patch cords not exceeding 33 feet (10 meters) and all cables color-coded by system type (blue for data communications, white for access points, yellow for security cameras, and red for fire alarm). The owner will provide the building entrance fiber optic cable, modem/router, enterprise security gateway, and managed network POE switch, while the contractor is responsible for all rough-in work, cable termination, equipment installation, system testing, and programming coordination with the architect and owner.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NOT TO SCALE
0109-1A01
RACK ROOM NUMBER
RACK NUMBER
SYMBOL: ( )SYMBOL: ( )
CATEGORY 6A, 2-PORT ANGLED DATA COUPLER, EQUAL TO BELDEN
AX102413 INSERT WITH (2) 8P CAT 6A MODULAR JACKS, EQUAL TO BELDEN
REVCONNECT RV6MJKUEW, COLOR ELECTRIC WHITE.
CATEGORY 6A, 2-PORT ANGLED DATA COUPLER, BELDEN AX102413
INSERT WITH (1) 8P CAT 6A MODULAR JACKS, BELDEN REVCONNECT
RV6MJKUEW AND ONE BLANK COVER, COLOR ELECTRIC WHITE.
FACEPLATE EQUAL TO BELDEN AX101747. COLOR ELECTRIC WHITE,
PROVIDE (1) BELDEN AX101759 FILLER AND (1) BELDEN AX1011763 FILLER.
109-1
109-1
OUTLET DETAIL NOTES:
CABLE LABEL IDENTIFICATION
OUTLET CONFIGURATION DETAIL
TYPICAL TELECOM EQUIPMENT
NAMEPLATE
NOT TO SCALE
4" MAX.
2" MAX.
MICARTA ENGRAVED NAMEPLATE WITH
BLACK LETTERS ON WHITE BACKGROUND,
MECHANICALLY AFFIXED TO COMM RACK,
ENCLOSURE OR BACKBOARD WITH
BOLTS, NUTS AND WASHERS
1/2" LETTERS IDENTIFYING
TELECOM EQUIPMENT (MIN.)
A01 A02 A01
109-1
A03 A04
A01 A02
A A
109-1
1 2 3 4 5 6
25 26 27 28 29 30
7 8 9 10 11 12
31 32 33 34 35 36
13 14 15 16 17 18
37 38 39 40 41 42
19 20 21 22 23 24
43 44 45 46 47 48
ROOM NUMBER
PATCH PANEL DESIGNATION
& PORT NUMBER
RACK #
RACK #
PATCH PANEL
DESIGNATION
PATCH PANEL
DESIGNATION
PATCH PANEL
PORT NUMBER
109-1A01 109-1A01
CABLE LABELING. PROVIDE
PRINTED IDENTIFIER WITHIN
6" OF TERMINATED JACK.
PATCH PANEL DESIGNATION
PATCH PANEL PORT NUMBER
NOT TO SCALE
COMM OUTLET TO PATCH PANEL LABELING NOMENCLATURE
COMM RACK
PATCH PANEL
TYPICAL COMM
CABLE
TYPICAL COMM
OUTLET
COMMUNICATIONS RACK
PATCH CORD
TELECOM OUTLET COUPLER,
8P MODULAR KEYSTONE JACK
PATCH PANEL COUPLER,
8P MODULAR KEYSTONE JACK
HORIZONTAL CABLING
NOT TO SCALE
568B WIRING CONNECTION DETAIL
MAKE TERMINATIONS IN
ACCORDANCE WITH
MANUFACTURER'S
INSTRUCTIONS FOR THE
CABLE AND JACK / COUPLER.
PROVIDE ENOUGH
CABLE SLACK FOR FOUR
RE-TERMINATIONS
WITHOUT RE-ROUTING
CABLE.
TELECOM SYSTEMS SYMBOLS
FLR CLG WALL
COMMUNICATIONS OUTLET WITH COUPLERS AND COVERPLATE; INSTALL 3/4"C WITH CABLE UP INTO CEILING
SPACE. SEE DETAILS FOR CONDUIT REQUIRED LOCATIONS. WALL MOUNT 18" AFF UNO.
COMMUNICATIONS OUTLET WITH COVERS AND COVERPLATE FOR VIDEO MONITORS. LOCATED IN RECESSED
WALL BOX; SEE BOX DETAILS. SEE DETAILS FOR CONDUIT REQUIRED LOCATIONS.
WIRELESS ACCESS POINT: CONTRACTOR TO PROVIDE CABLE IN 3/4" CONDUIT UNLESS NOTED OTHERWISE. SEE
DETAILS FOR CONDUIT REQUIRED LOCATIONS.
T E L E C O M M U N I C A T I O N S L E G E N D
ABBREVIATIONS
AFF - ABOVE FINISHED FLOOR
AHJ - AUTHORITY HAVING JURISDICTION
AWG - AMERICAN WIRE GAUGE
BLDG - BUILDING
CAT 6 - CATEGORY 6
CAT 6A - CATEGORY 6 AUGMENTED
CO - COMMUNICATIONS OUTLET
CFCI - CONTRACTOR FURNISHED, CONTRACTOR INSTALLED
CFOI - CONTRACTOR FURNISHED, OWNER INSTALLED
CLG - CEILING
DWG - DRAWING
EC - ELECTRICAL CONTRACTOR
ELEC - ELECTRICAL
FA - FIRE ALARM
FLR - FLOOR
FO - FIBER OPTIC
GND - GROUNDED
JB - JUNCTION BOX
LAN - LOCAL AREA NETWORK
MTG - MOUNTING
NEC - NATIONAL ELECTRICAL CODE
NIC - NOT IN CONTRACT
N/A - NOT APPLICABLE
OFCI - OWNER FURNISHED, CONTRACTOR INSTALLED
OFOI - OWNER FURNISHED, OWNER INSTALLED
PP - PATCH PANEL
RMU - RACK MOUNT UNIT
UPS - UNINTERRUPTIBLE POWER SUPPLY
UTP - UNSHIELDED TWISTED PAIR
UNO - UNLESS NOTED OTHERWISE
WAP - WIRELESS ACCESS POINT
COMMUNICATIONS OUTLET TO COMM RACK
CABLING COLOR CODE
COMM ROOM - COMMUNICATIONS OUTLET PATCH CORD
WIRELESS ACCESS POINT TO COMM RACK
COMM ROOM - WIRELESS ACCESS POINT PATCH CORD
FIRE ALARM PANEL TO COMM RACK
SECURITY PANEL TO COMM RACK
LIGHTING CONTROL COMMUNICATIONS CABLING
BLUE
BLUE
WHITE
WHITE
RED
BLACK
GRAY
COMMUNICATIONS OUTLET DESIGNATIONS
PLYWOOD BACKBOARD; 3/4" THICK; PAINT WITH TWO COATS OF FIRE RETARDANT PAINT.
CONDUIT ROUTING NOTES
A. LOCATION AND ROUTING OF CONDUIT IS APPROXIMATE AND DEPICTS DESIGN INTENT ONLY. THE
CONTRACTOR IS SOLELY RESPONSIBLE FOR DETERMINING AND FIELD VERIFYING FINAL CONDUIT ROUTING. THE CONTRACTOR SHALL COORDINATE THE FINAL ROUTING OF CONDUITS TO AVOID CONFLICTS WITH OTHER TRADES
WHILE MINIMIZING CHANGES IN DIRECTION AND OVERALL CONDUIT LENGTH.
B. SUPPORT CONDUIT FROM BUILDING STRUCTURE. DO NOT SUPPORT CONDUITS FROM OTHER SYSTEM COMPONENTS
OR SUPPORTS.
C. TERMINATE ALL CONDUIT ENDS WITH THREADED PLASTIC INSULATING BUSHINGS. BUSHINGS MUST FIT TIGHTLY ON
CONDUIT CONNECTOR THREADS. INSTALL BUSHINGS PRIOR TO PULLING CABLES.
D. IDENTIFY ALL CONDUITS AND PULLBOXES WITH BLUE PAINT. PAINT EACH CONDUIT COUPLING AND PULLBOX COVER.
OUTLET LOCATION NOTES
A. ALL COMMUNICATION OUTLET LOCATIONS ARE APPROXIMATE. THE CONTRACTOR SHALL COORDINATE THE EXACT
LOCATION OF EACH OUTLET WITH THE ARCHITECT AND GENERAL CONTRACTOR PRIOR TO ROUGH-IN.
B. COMMUNICATION OUTLET LOCATIONS SHALL BE COORDINATED WITH WINDOWS, CASEWORK, DOOR SWINGS, COUNTER BACKSPLASHES AND ALL OTHER OBSTRUCTIONS.
A. CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES PRIOR TO INSTALLATION. REFER TO ELECTRICAL, MECHANICAL AND PLUMBING DRAWINGS FOR EXACT SIZE AND LOCATION OF EQUIPMENT WHICH IS FURNISHED BY OTHERS.
B. DEVICES AND COVERPLATES COLOR SHALL BE SELECTED BY THE ARCHITECT FROM STANDARD COLORS FOR EACH SPACE.
C. ALL METAL PARTS OF COMMUNICATION RACKS AND EQUIPMENT SHALL BE GROUNDED THROUGH GROUND BUS. CONTRACTOR SHALL VERIFY THAT NO TWO PIECES OF EQUIPMENT IN ANY TELECOMMUNICATIONS SYSTEM HAVE A POTENTIAL DIFFERENCE
GREATER THAN 500 MILLIVOLTS.
D. CONTRACTOR SHALL SUPPLY A MICARTA NAMEPLATE MECHANICALLY AFFIXED FOR EACH COMMUNICATIONS RACK, BACKBOARD
AND TERMINAL CABINET. THE NAMEPLATE SHALL IDENTIFY THE SYSTEM..
E. ALL TURNS IN CONDUIT SHALL BE SWEPT CONDUIT OR MANUFACTURED ELBOWS. NO CONDULETS WILL BE ALLOWED.
F. ALL COMMUNICATIONS CABLING, WHETHER INSTALLED IN CONDUIT OR NOT, SHALL BE INSTALLED A MINIMUM OF 8" CLEAR FROM 120V ELECTRICAL, ALARM OR OTHER WIRING AND 12" CLEAR FROM MOTORS, LIGHT FIXTURES OR SOUND SYSTEM. A MINIMUM 6"
CLEARANCE FOR THE SAME SHALL APPLY AT PERPENDICULAR CROSSOVER POINTS.
G. ALL JUNCTION BOXES, CONDUIT, HANGERS AND CABLING SHALL BE MOUNTED HIGH ENOUGH ABOVE THE SUSPENDED CEILING SO AS NOT TO INTERFERE WITH THE REMOVAL OR SERVICING OF CEILING TILES, LIGHT FIXTURES OR THE HVAC SYSTEM.
H. ALL EXPOSED CONDUITS, BOXES, STRAPS AND HANGERS IN THE CONTRACT AREA THAT ARE PART OF THE TELECOM SYSTEM
SHALL BE PAINTED TO MATCH ADJACENT FINISH.
I. IN NO CASE SHALL ANY TELECOM CONDUIT HAVE MORE THAN TWO 90 DEGREE BENDS WITHOUT TERMINATING IN A PULLBOX.
PULLBOXES SHALL NOT BE USED FOR A CHANGE OF DIRECTION.
J. ALL CABLES SHALL BE LABELED AT BOTH ENDS WITH THE COMMUNICATIONS OUTLET NUMBER AND THE PATCH PANEL OUTLET
NUMBERS.
K. ALL TELECOMMUNICATION OUTLETS SHALL BE INSTALLED FLUSH IN WALLS OR FLOOR BOXES.
L. ALL PENETRATIONS OF FLOORS AND WALLS WHICH EXTEND TO THE UNDERSIDE OF THE FLOOR OR ROOF DECK SHALL BE FIRESTOPPED. FIRESTOPPING SHALL BE PROVIDED USING U.L. LISTED SYSTEMS WITH THE FIRE RATING EQUAL TO OR GREATER THAN THE FIRE RATING OF THE FLOOR OR WALL ASSEMBLY. INSTALL ALL FIRESTOP MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. THE CONTRACTOR SHALL SUBMIT A DETAIL FOR EACH TYPE OF PENETRATIONS REQUIRED.
M. PROVIDE NO LESS THAN ONE SINGLE PORT DATA CABLE TO EACH OF THE FOLLOWING SPECIAL SERVICE CABINETS: A) FIRE ALARM SYSTEM, B) SECURITY SYSTEM, C) CCTV SYSTEM. COORDINATE LOCATIONS AND INTERFACE REQUIREMENTS WITH THE INSTALLER FOR EACH SPECIAL SYSTEM. CABLING SHALL BE HOME RUN IN CONDUIT TO COMM RACK.
N. THE INSTALLING CONTRACTOR SHALL INSTALL THE FOLLOWING AMOUNTS OF COMMUNICATIONS CABLE SLACK: COMMUNICATIONS
OUTLET - 1'6"; TELECOM CLOSET/ROOM - 20'-0".
T E L E C O M M U N I C A T I O N S G E N E R A L N O T E S
LETTERS +XX" ADJACENT TO SYMBOL INDICATES RECEPTACLE MOUNTING HEIGHT. WHERE NO HEIGHT IS
INDICATED MOUNT 18" AFF TO C/L.
+AC" = ABOVE COUNTER.
+TV" = VERIFY HEIGHT OF TV WITH OWNER.
NUMBER "2" INDICATES NUMBER OF PORTS. NO NUMBER INDICATES ONE (1)
RE
NG
LE
8:0 8 A
M
- T
1.0 0 L
EG
EN
D
AN
D
NO
TE
S.
dw g
Job No.
Christopher A. Garick; FL. PE No.53924 Daniel J. White; FL. PE No.73790 Caleb W. Leonard; FL. PE No.91782
HG Engineers 142 Eglin Parkway SE Fort Walton Beach, Florida, 32548 E-mail: office@hgengineers.com Ph: 850.243.6723 Fl. Authorization No.00006680
26004 llc
D A
TE
D R
A W
N B
Y:
P R
O
JE
C T
N O
R E
VI
S
IO
N
S
S E
P T
, 2
R .E
N G
LE
C .P
A S
TO
R
IU
S
S
EP
T
FO
R
B
ID
P R O
FESS IONA L ENG
I N E
E R
CH
R
IS
TO
PHER A . GAR
ICKL I C E N S E
STATE OF
No. 53924
FLO RIDA
C R
E S
TV
IE
W , F
LO
R
ID
A
O ka lo os a C ou nt y
O
LD
B E
TH
E
L R
O A
D
Fa ci lit ie s W ar eh ou se
T1 .0
LE
G
E N
D A
N D
N O
TE
S
Sheet Index Sheet
Number Sheet Title
T1.00 LEGEND AND NOTES
T2.00 FLOOR PLAN SYSTEMS
T3.00 TELECOMMUNICATIONS DETAILS
T3.01 TELECOMMUNICATIONS DETAILS
T3.02 ACCESS CONTROL DETAILS
T3.03 IP SECURITY CCTV DETAILS
TELECOM BACKBOARD, 4FT. WIDE X 8 FT. HIGH X 3/4" EXTERIOR PLYWOOD. PAINT TWO
COATS FIRE RETARDANT PAINT. INSTALL ONE NO. 6 COPPER GROUND CONDUCTOR IN
3/4" CONDUIT TO BUILDING GROUND, LEAVE 4 FT. SLACK CONDUCTOR AT BACKBOARD.
ACCESS CONTROL DOOR - REFER TO DETAILS.
INSTALL (2)2" EMPTY CONDUIT WITH PULLRIBBONS BACK TO TELECOM BACKBOARD,
STUB-UP 6" AFF; FOR FUTURE USE. STUB-OUT, CAP AND MARK LOCATION. SEAL ALL
CONDUIT SEGMENTS.
INSTALL ELECTRICAL PULLBOX FOR TELECOM UTILITY SERVICE ENTRANCE. REFER TO
SITE PLAN FOR CONTINUATION
NOTES:
MDP
A
SH
J
J J
J
+48"
J J
3R230
J
SHOP
WAREHOUSE
CONCRETE
APRON
SUPERVISOR
ASSISTANT
WORKROOM
GROUNDS
SUPERVISOR
STAFF
MECH/ELEC
109BREAK RM
108TLT
TLT
MAINT
PORCH
2 2
TELECOM WALL
MOUNTED RACK
ACCESS CONTROL
SYSTEM PANEL
CC
CCC
CC C
C
101C 102C 105A
102G
102F101D
105B
+120"
RE
NG
LE
8:0 8 A
M
- T
2.0 0 F
LO
OR
P
LA
N
SY
ST
EM
S.
dw g
Job No.
Christopher A. Garick; FL. PE No.53924 Daniel J. White; FL. PE No.73790 Caleb W. Leonard; FL. PE No.91782
HG Engineers 142 Eglin Parkway SE Fort Walton Beach, Florida, 32548 E-mail: office@hgengineers.com Ph: 850.243.6723 Fl. Authorization No.00006680
26004 llc
D A
TE
D R
A W
N B
Y:
P R
O
JE
C T
N O
R E
VI
S
IO
N
S
S E
P T
, 2
R .E
N G
LE
C .P
A S
TO
R
IU
S
S
EP
T
FO
R
B
ID
P R O
FESS IONA L ENG
I N E
E R
CH
R
IS
TO
PHER A . GAR
ICKL I C E N S E
STATE OF
No. 53924
FLO RIDA
C R
E S
TV
IE
W , F
LO
R
ID
A
O ka lo os a C ou nt y
O
LD
B E
TH
E
L R
O A
D
Fa ci lit ie s W ar eh ou se
FLOOR PLAN SYSTEMS
1/8" = 1'-0" 4' 8' 16'
T2 .0
FL
O
O R
P
LA
N S
YS
TE
M S
DATA SYSTEM RISER DIAGRAM
INSULATED GROUNDING BAR DETAIL
NOT TO SCALE
GROUND BAR NOTES:
1. INSTALL ONE BAR AT EACH COMMUNICATIONS ROOM.
2. ROUTE 1#4 BARE CU IN 1"CONDUIT FROM GROUND BAR TO
BUILDING ELECTRICAL SERVICE ENTRANCE GROUND.
3. CONNECT BARS WITH 1#6 BARE CU IN 1" CONDUIT.
3/8" DIA.
10"L (COPPER)
NO DESCRIPTION
GROUND BAR
WALL MTG. BRACKET
INSULATORS
5/8"X1" H.H.C.S. BOLT
5/8" LOCKWASHER
DATA SYSTEM NOTES:
BUILDING ENTRANCE CABLE (FIBER WHERE AVAILABLE) PROVIDED AND INSTALLED BY OWNER.
MODEM / ROUTER AND/OR ENTERPRISE SECURITY GATEWAY PROVIDED BY OWNER.
FIBER PATCH PANEL FOR UTILITY FIBER WITH SPLICE TRAY; COORDINATE WITH OWNER ON CONNECTOR TYPE.
CABLE TO GATEWAY BY OWNER.
HORIZONTAL WIRING CABLES. CATEGORY 6A, FOUR-PAIR 100-OHM UNSHIELDED TWISTED PAIR (UTP) CABLE WITH 24 AWG SOLID PAIR CONDUCTORS. MAXIMUM LENGTH 90 METERS (295'). CABLE COLOR SHALL BE BLUE FOR DATA
AND WHITE FOR ACCESS POINTS. TERMINATE CABLES AT PATCH PANEL "A1".
IP SECURITY CAMERA CABLES. CATEGORY 6, FOUR-PAIR 100-OHM UNSHIELDED TWISTED PAIR (UTP) CABLE WITH 24 AWG SOLID PAIR CONDUCTORS. MAXIMUM LENGTH 90 METERS (295'). CABLE COLOR SHALL BE YELLOW.
TERMINATE CABLES AT PATCH PANEL "CAM".
EQUIPMENT PATCH CORDS. CATEGORY 6A, FOUR-PAIR 100-OHM UTP CABLE WITH 24 AWG SOLID PAIR
CONDUCTORS. PROVIDE BLUE FOR COMM OUTLETS AND WHITE FOR ACCESS POINTS.
EQUIPMENT PATCH CORDS. CATEGORY 6, FOUR-PAIR 100-OHM UTP CABLE WITH 24 AWG SOLID PAIR
CONDUCTORS. PROVIDE YELLOW FOR IP SECURITY CAMERAS.
OFCI MANAGED NETWORK POE SWITCH; PROVIDED BY OWNER AND INSTALLED BY CONTRACTOR.
48 PORT MODULAR OPEN BLADE PATCH PANEL "A1"; SEE PATCH PANEL SCHEDULE. PROVIDE COLORED SNAP-IN, CAT 6A RATED, 8-POSITION (RJ45) JACKS TO MATCH CABLE COLOR..
24 PORT MODULAR OPEN BLADE PATCH PANEL "CAM"; SEE PATCH PANEL SCHEDULE. PROVIDE COLORED
SNAP-IN, CAT 6 RATED, 8-POSITION (RJ45) JACKS TO MATCH CABLE COLOR..
OFCI ACCESS POINT.
FIBER OPTIC PATCH CORD; DUAL STRAND, DIELECTRIC, FACTORY TERMINATED AND TESTED.
2-2" EMPTY CONDUIT FOR TELECOMMUNICATIONS
SERVICE ENTRANCE REQUIREMENTS. REFER TO
SITE PLAN FOR MORE INFORMATION.
A1
TELECOM RACK
ELEC/COMM 109
PATCH CORD NOTE:
Color Patch Cord
PATCH CORD QUANTITY SCHEDULE
Length (m)
BLUE (Comm Outlet) -
TIA-568 ALLOWS A MAXIMUM OF 33 FT (10M) FOR ALL CROSS CONNECT AND EQUIPMENT PATCH CORDS. CROSS CONNECT AND EQUIPMENT PATCH CORDS SHALL BE KEPT AS SHORT AS POSSIBLE BUT STILL ALLOW FOR PROPER CONNECTION. THERE SHALL BE NO TENSION IN THE CORDS THAT
CAUSE CONNECTIONS TO EQUIPMENT TO LOOSEN OR DEGRADE SERVICE. CORDS SHALL HAVE
MINIMAL SLACK.
WHITE (Access Point) -
YELLOW (Security Camera) -
Total # of Cat 6 Patch Cords Length (m)
Total # of Cat 6a Patch Cords Location
109.1
RED (Fire Alarm) - - - 1
-11
- 30
NON ACCESSIBLE CEILING ACCESSIBLE CEILING
FLAT SCREEN TELEVISION/MONITOR
CONDUITS FOR POWER AND DATA
6"
MIN
FLAT PANEL OUTLET MOUNTING DETAIL
2"C FOR DATA3/4"C FOR POWER
WALL BOX EQUAL TO LEGRAND EVOLUTION
SERIES EFSB2, COMPONENTS TO INCLUDE
MOUNTING BRACKETS, MODULES, TRIM AND
DECORATIVE COVER.
NOT TO SCALE
CAM
COMMUNICATIONS
OUTLET
TYPICAL
ACCESS
POINT
TYPICAL
IP
SECURITY
CAMERA
TYPICAL
COMM BACKBOARD
ELEC/COMM ROOM 109
FLAT PANEL
DISPLAY
OUTLET TYPICAL
30" AFF
109-1 1
RACK EQUIPMENT SCHEDULE
COMMUNICATION EQUIPMENT RACK, 43" H x 25" D WALL MOUNT SWING OUT
RACK, EQUAL TO CHATSWORTH 11791-E25 WITH HEAVY DUTY SWING GATE KIT,
PATCH PANEL. 48-PORT MODULAR OPEN BLADE PATCH PANEL WITH SNAP-IN
8-POSITION (RJ45) JACKS. SEE SCHEDULE.
OWNER MODEM/ROUTER AND/OR OFCI ENTERPRISE SECURITY GATEWAY
UPS; EATON 5PX2200RT 2KVA RACK MOUNT WITH NETWORK CARD. PROVIDE
MINIMUM 12 FT POWER CORD.
OFCI MANAGED NETWORK POE SWITCH
FRONT & REAR CABLE MANAGEMENT PANEL EQUAL TO PANDUIT
#WMP1E. 3.5"HX19"WX8.4"D.
FRONT & REAR CABLE MANAGEMENT PANEL EQUAL TO PANDUIT
#WMPLSE. 1.7"HX19"WX7.4"D.
GLACIER WHITE IN COLOR. PROVIDE WITH SIX RINGS, CHATSWORTH 11799-001.
TELECOM GROUNDING BUSBAR (TBB), EQUAL TO HARGER GBI14412J. MOUNT TO
ONE #4 CU GROUNDING ELECTRODE CONDUCTOR IN 1" CONDUIT TO BUILDING GROUND.
EQUIPMENT SHELF
FIBER DRAWER WITH SPLICE TRAY. COORDINATE WITH OWNER ON CONNECTOR TYPES.
PROVIDE WITH SIDE LOUVERED PANELS AND FRONT SCREEN PANEL.
BACKBOARD.
PATCH PANEL. 24-PORT MODULAR OPEN BLADE PATCH PANEL WITH SNAP-IN
8-POSITION (RJ45) JACKS. SEE SCHEDULE.
PATCH
PANEL "CAM"
CAM CAM12
PATCH
PANEL "A1"AA
RACK ELEVATION
NOT TO SCALE
RE
NG
LE
8:0 8 A
M
- T
3.0 0 T
EL
EC
OM
MU
NI
CA
TI
ON
S
DE
TA
ILS
.dw g
Job No.
Christopher A. Garick; FL. PE No.53924 Daniel J. White; FL. PE No.73790 Caleb W. Leonard; FL. PE No.91782
HG Engineers 142 Eglin Parkway SE Fort Walton Beach, Florida, 32548 E-mail: office@hgengineers.com Ph: 850.243.6723 Fl. Authorization No.00006680
26004 llc
D A
TE
D R
A W
N B
Y:
P R
O
JE
C T
N O
R E
VI
S
IO
N
S
S E
P T
, 2
R .E
N G
LE
C .P
A S
TO
R
IU
S
S
EP
T
FO
R
B
ID
P R O
FESS IONA L ENG
I N E
E R
CH
R
IS
TO
PHER A . GAR
ICKL I C E N S E
STATE OF
No. 53924
FLO RIDA
C R
E S
TV
IE
W , F
LO
R
ID
A
O ka lo os a C ou nt y
O
LD
B E
TH
E
L R
O A
D
Fa ci lit ie s W ar eh ou se
T3 .0
TE
LE
C O
M M
U N
IC
A
TI
O
N S
D E
TA
IL
18"
AFF
(TYP)
COMMUNICATIONS
OUTLET (CO)
(TYPICAL)
FINISHED
FLOOR
PROVIDE SLACK LOOP
WITH 1 FT SPARE
CABLE
CATEGORY-6A
CABLING IN CONDUIT
THRU WALL SPACE
SHEETROCK OR OTHER
INACCESSIBLE CEILING.
(TYPICAL)
PAINT COUPLERS AND ANY PULL BOX
COVERS BLUE WHERE USED AS
COMMUNICATIONS CONDUIT PATHS.
STUB-OUT WHERE CEILING BECOMES
ACCESSIBLE. PROVIDE CABLE HANGERS
UNTIL ROUTING REACHES CABLE TRAY.
NTS
COMMUNICATIONS OUTLET
INSTALLATION DETAIL
AT INACCESSIBLE CEILING LOCATIONS
NTS
COMMUNICATIONS OUTLET
INSTALLATION DETAIL
AT ACCESSIBLE CEILING LOCATIONS
18"
AFF
(TYP)
COMMUNICATIONS
OUTLET (CO)
(TYPICAL)
FINISHED
FLOOR
PROVIDE SLACK LOOP
WITH 1 FT SPARE
CABLE
CATEGORY-6A
CABLING IN CONDUIT
THRU WALL SPACE
CEILING GRID
PERIMETER RAIL
(TYPICAL)
CEILING TILE
(TYPICAL)
PROVIDE SLACK
LOOP WITH 1 FT SPARE
CABLE
BIND CABLING
NEATLY WITH
VELCRO STRAPS
HORIZONTAL CABLING
(TYPICAL)
CONDUIT STUB OUT ABOVE
FINISHED CEILING WITH
BUSHING.
PROVIDE CABLE HANGERS UNTIL ROUTING
REACHES CABLE TRAY OR CONDUIT.
CABLE HANGERS @ 4'-0" O.C.
TELECOM
CABLE BUNDLES J-HOOK
1'-0" MIN.
ROOF STRUCTURE
4'-0" 4'-6" 5'-0"
ACCESSIBLE
CEILING
3.
2.
1.
CABLE ROUTING NOTES
4" SQUARE x 2-1/8" DEEP
WALL BOX.
SINGLE GANG PLASTER RING
COVER.
FACEPLATE
ROUTE PERPENDICULAR & PARALLEL TO BUILDING LINES.
BUNDLE CABLES WITH PANDUIT PAN-TY PRT4S-C WITH
RELEASABLE LOOP AT EACH HANGER.
HANGERS FOR CABLES SHALL BE J-HOOKS EQUAL TO ERICO
CADDY CAT 32 HP. COLOR SHALL BE BLUE.
CABLE ROUTING DETAIL
TYPICAL FLUSH MOUNT COMMUNICATIONS OUTLET DETAIL
NTS
NTS
COMMUNICATIONS CABLING DETAIL
RACK-MOUNTED
SWITCH EQUIPMENT
HORIZONTAL CABLING:
EIA/TIA CATEGORY 6A, 4-PAIR 100-OHM UNSHIELDED
TWISTED PAIR (UTP) CABLE WITH 23 GAGE SOLID PPER
CONDUCTORS. BELDEN 10GXW13, SIEMON, ESSEX,
OR ENGINEER APPROVED EQUAL.
TELECOM OUTLET CONNECTOR:
MODULAR 8-PIN JACK ASSEMBLY, EIA/TIA
CATEGORY 6A WITH 110 STYLE
IDC CONNECTING HARDWARE AND EIA/TIA
568B PIN/PAIR ASSIGNMENT.
COMPLETE CABLE LENGTH NOT TO
EXCEED 278 ft (85m) LABEL EACH END
OF CABLE. PROVIDE ONE CABLE FOR
EACH COMM OUTLET COUPLER.
RACK-MOUNTED
PATCH PANEL
COMPLETE CABLE
LENGTH NOT TO
EXCEED 30 ft (10m)
COMMUNICATIONS RACK PATCH CORD:
PATCH CORD, EIA/TIA CATEGORY 6A 4-PAIR 100-OHM UNSHIELDED TWISTED
PAIR (UTP) CABLE WITH 23 GAGE STRANDED COPPER CONDUCTORS. PROVIDE
AN 8-PIN MODULAR PLUG ON EACH END WITH EIA/TIA 568B PIN/PAIR
ASSIGNMENTS AND MOLDED STRAIN RELIEF BOOT. EQUAL TO BELDEN
CA2110#00# OR ENGINEER APPROVED EQUAL. PROVIDE LENGTHS, QUANTITIES
AND COLORS AS REQUIRED TO CONNECT TO SWITCH EQUIPMENT.
4. MAXIMUM NUMBER OF CABLES OR BUNDLE SIZE IS 25 FOR
CAT 6A AND 40 FOR CAT 5 OR 6.
5. EACH CATEGORY OF CABLE SHALL BE BUNDLED TOGETHER
WITH LIKE CABLE, SEPARATE FROM OTHER CATEGORIES OF
CABLING. I.E. DON'T BUNDLE CAT 6 WITH CAT 6A.
MOUNT TO ROOF
STRUCTURE PER MANF
INSTRUCTIONS.
WIRELESS ACCESS POINT
DIRECT CONNECT CABLE TO WAP
WITH CAT 6A 8-PIN MODULAR PLUG
AND STRAIN RELIEF BOOT.
PROVIDE TWO 18" LOOPS
FOR CABLE SLACK
ACCESSIBLE
CEILING
CABLE HANGERS (J HOOKS). MOUNT
WITHIN TWO FEET RADIUS OF WAP.
NO HIGHER THAN SIX FEET ABOVE.
NTS
NTS
WIRELESS ACCESS POINT MOUNTING DETAIL
SPACE 4 TO 5 FT MAX APART.
COORDINATE WITH STRUCTURE.
RE
NG
LE
8:0 8 A
M
- T
3.0 1 T
EL
EC
OM
MU
NI
CA
TI
ON
S
DE
TA
ILS
.dw g
Job No.
Christopher A. Garick; FL. PE No.53924 Daniel J. White; FL. PE No.73790 Caleb W. Leonard; FL. PE No.91782
HG Engineers 142 Eglin Parkway SE Fort Walton Beach, Florida, 32548 E-mail: office@hgengineers.com Ph: 850.243.6723 Fl. Authorization No.00006680
26004 llc
D A
TE
D R
A W
N B
Y:
P R
O
JE
C T
N O
R E
VI
S
IO
N
S
S E
P T
, 2
R .E
N G
LE
C .P
A S
TO
R
IU
S
S
EP
T
FO
R
B
ID
P R O
FESS IONA L ENG
I N E
E R
CH
R
IS
TO
PHER A . GAR
ICKL I C E N S E
STATE OF
No. 53924
FLO RIDA
C R
E S
TV
IE
W , F
LO
R
ID
A
O ka lo os a C ou nt y
O
LD
B E
TH
E
L R
O A
D
Fa ci lit ie s W ar eh ou se
T3 .0
TE
LE
C O
M M
U N
IC
A
TI
O
N S
D E
TA
DOOR ROUGH-IN DETAIL
UNSECURE SIDESECURE SIDE
MAIN JUNCTION BOX
MOUNTED IN AN ACCESSIBLE
LOCATION ON SECURE SIDE.
ROUTE TO ACSP
POWER TRANSFER AT
FACTORY BACKBOXES.
UTILIZE SECURITRON
CEPT STYLE FOR
TRANSFER. PROVIDE
MORTAR BOX AS
REQUIRED FOR CMU
BLOCK OR BRICK WALLS.
ELECTRIFIED
LOCKSET WITH
INTEGRAL RQE
RUN CIRCUIT
CONCEALED IN
DOOR JAMB.
120V AC
ELRQE
MBPT
JB
PS
DPS
SECURED SIDE
UNSECURED SIDE
DOOR POSITION
SWITCH
SECURE SINGLE DOOR WITH LOCKSET
PLAN VIEW
ISOMETRIC VIEW
COORDINATE WITH ACCESS CONTROL
SYSTEM REQUIREMENTS, POWER MAY BE IN
COMPOSITE CABLE FROM ACSP.
120V AC ROUTE TO ACSP
48"
CARD READER ON
UNSECURE SIDE.
MOUNT ON SINGLE
GANG x 3-1/2" DEEP
WALL BOX.
1/2" C.
DOOR OPERATION
1. Door normally closed and secure.
2. Authorized access by card reader unlocking lever trim for a predetermined time limit.
3. Mortise lock REX switch allows free egress.
4. Door position switch monitors open/closed/latched status.
5. Lever remains locked (fail secure) in event of power loss.
6. Keyed cylinder override for emergency access
A C C E S S C O N T R O L L E G E N D
SYSTEM SYMBOLS
DOOR POSITION SWITCH
ELECTRIFIED LOCKSET
JUNCTION BOX
MORTAR BOX
DPS
EL
JB
MB
PT
RQE
POWER TRANSFER
REQUEST-TO-EXIT
PS POWER SUPPLY
ACCESS CONTROL SYSTEM PANELACSP
CARD READER
CARD READER NOTES
CARD READER SHALL BE WALL OR MULLION MOUNTED. INSTALL USING FACTORY MOUNTING PLATE PROVIDED BY
MANUFACTURER.
PROVIDE SINGLE GANG DEEP WALL BOX FOR CARD READERS INSTALLED IN WALLS. PROVIDE MASONRY BOX WHERE MOUNTED IN BLOCK / BRICK. DO NOT PROVIDE AN OVERSIZED PLATE TO COVER UNFINISHED OPENINGS AROUND WALL
BOX. ALL EXTERIOR CARD READER LOCATIONS SHALL BE WATERTIGHT.
DOOR POSITION SWITCH NOTE
DOOR POSITION SWITCHES SHALL BE NORMALLY OPEN. EACH SWITCH SHALL BE HELD IN THE CLOSED POSITION WHEN DOOR IS CLOSED. THE SWITCH SHALL MOVE TO THE OPEN POSITION WHEN DOOR IS OPENED. OPEN CIRCUIT
SHALL GENERATE AN ALARM STATE UNLESS AN RQE IS SIGNALED.
SECURE DOOR OPERATION
PRESENTING VALID DOOR CREDENTIAL TO CARD READER SIGNALS ELECTRIC UNLOCKING OF THE ELECTRIFIED EXIT DEVICE OR THE ELECTRIFIED LOCKSET. THE DOOR POSITION SWITCH MONITORS THE STATUS OF EACH DOOR FOR DOOR HELD OPEN OR UNAUTHORIZED ENTRY. A REQUEST-TO-EXIT SWITCH INTERNAL TO EXIT DEVICE OR LOCKSET AND CONNECTED TO THE ACCESS CONTROL / ALARM SYSTEM IS ACTIVATED UPON EXITING FROM THE SECURE SIDE
SIGNALING AN AUTHORIZED EXITING.
A C C E S S C O N T R O L G E N E R A L N O T E S
ABBREVIATIONS
ADA - AMERICANS WITH DISABILITIES ACT
ACS - ACCESS CONTROL SYSTEM
ACSC - ACCESS CONTROL SYSTEM CONTRACTOR
EC - ELECTRICAL CONTRACTOR
GC - GENERAL CONTRACTOR
A. CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES PRIOR TO INSTALLATION. REFER TO ELECTRICAL, MECHANICAL AND PLUMBING DRAWINGS FOR EXACT SIZE AND LOCATION OF EQUIPMENT WHICH IS FURNISHED BY OTHERS.
B. ALL ACCESS CONTROL CABLING SHALL BE RUN CONTINUOUSLY IN CONDUIT. CONDUIT TYPES ARE AS DEFINED IN ELECTRICAL DRAWINGS & SPECIFICATIONS. MINIMUM SIZE IS 3/4" EXCEPT AT DOOR FOR CONNECTIONS WHERE 1/2" IS ALLOWED. ALL CONDUIT SHALL BE CONCEALED IF AT ALL POSSIBLE WHERE EXISTING WALLS DO NOT PROVIDE FOR IT. EXPOSED CONDUITS TO PUBLIC SHALL BE GRC.
C. ALL JUNCTION BOXES, CONDUIT, HANGERS AND CABLING SHALL BE MOUNTED HIGH ENOUGH ABOVE THE SUSPENDED CEILING SO AS NOT TO INTERFERE WITH THE REMOVAL OR SERVICING OF CEILING TILES, LIGHT FIXTURES OR THE HVAC SYSTEM. PAINT ACCESS CONTROL JUNCTION
BOX COVERS AND CONDUIT COUPLERS WHITE FOR ENTIRE ACCESS CONTROL SYSTEM.
D. ALL EXPOSED CONDUITS, BOXES, STRAPS AND HANGERS IN THE CONTRACT AREA THAT ARE PART OF THE ACCESS CONTROL SYSTEM SHALL
BE PAINTED TO MATCH ADJACENT FINISH.
E. ALL PENETRATIONS OF FLOORS AND WALLS WHICH EXTEND TO THE UNDERSIDE OF THE FLOOR OR ROOF DECK SHALL BE FIRESTOPPED.
FIRESTOPPING SHALL BE PROVIDED USING U.L. LISTED SYSTEMS WITH THE FIRE RATING EQUAL TO OR GREATER THAN THE FIRE RATING OF THE FLOOR OR WALL ASSEMBLY. INSTALL ALL FIRESTOP MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. THE
CONTRACTOR SHALL SUBMIT A DETAIL FOR EACH TYPE OF PENETRATIONS REQUIRED.
F. PROVIDE BUSHINGS ON ALL CONDUIT ENDS.
G. REFER TO DOOR HARDWARE SPECIFICATION AND DRAWINGS TO COORDINATE DOOR HARDWARE TYPES. POWER SUPPLIES SERVING SECURE DOORS WITH EXIT DEVICES SHALL BE PROVIDED AS PART OF THE DOOR HARDWARE PACKAGE AND SHALL BE THE SAME MANUFACTURER AS
THE EXIT DEVICE.
H. ALL DOORS SHALL HAVE MECHANICAL FREE EGRESS FROM SECURE SIDE TO UNSECURE SIDE UNLESS NOTED OTHERWISE BY DOOR
HARDWARE SPECIFICATIONS.
I. ALL DOORS SHALL FAIL SECURE UPON LOSS OF POWER TO LOCKING DEVICE UNLESS NOTED OTHERWISE BY DOOR HARDWARE
SPECIFICATIONS.
J. ALL SECURE DOORS SHALL HAVE REQUEST TO EXIT INTEGRAL TO THE DOOR HARDWARE SUCH THAT EGRESS THROUGH A SECURE DOOR FROM THE SECURE SIDE SHALL NOT GENERATE AN INTRUSION ALARM, UNLESS NOTED OTHERWISE BY DOOR HARDWARE SPECIFICATION.
K. PROVIDE WEATHERPROOF CARD READERS AND PUSH TO ENTER DEVICES AND CONSTRUCTION TECHNIQUES AT ALL EXTERIOR LOCATIONS.
L. CARD READER LOCATIONS ARE APPROXIMATE. EXACT LOCATION WITHIN VICINITY OF THE DOOR SERVED TO BE DETERMINED BY OWNER AND
ARCHITECT PRIOR TO ROUGHING-IN AT NO COST TO OWNER.
M. FINAL DOOR NUMBERS SHALL BE BASIS FOR SYSTEM LABELING AND PROGRAMMING. COORDINATE FINAL NUMBERS WITH OWNER AND
ARCHITECT PRIOR TO PROGRAMMING AND LABELING.
N. A DATA CONNECTION SHALL BE PROVIDED TO THE ACCESS CONTROL PANEL FOR CONNECTION TO THE ACCESS CONTROL / ALARM PANEL.
IMMEDIATE EMERGENCY NOTIFICATION SHALL BE SENT TO OWNER DESIGNATED RECEIVING STATION OF AN ALARM EVENT UPON ACTIVATION.
THE ACCESS CONTROL SYSTEM SHALL REPORT ALARM EVENTS TO THE OWNER DESIGNATED EMPLOYEE BY ANY COMBINATION OF TEXT, EMAIL,OR OTHER METHODS AS DESIGNATED BY THE OWNER.
O. AN ACCESS CONTROL / ALARM SYSTEM SHALL BE SET UP AS AN EXTENSION OF AND FULLY INTEGRATED WITH THE ACCESS CONTROL SYSTEM.
P. ALL CONDUIT AT SECURE AND MONITORED DOORS SHALL BE MOUNTED ON THE SECURE SIDE.
Q. PROVIDE A LOCKABLE ACCESS PANEL FOR ACCESS TO ABOVE CEILING JUNCTION BOXES ABOVE HARD CEILINGS.
ACCESS CONTROL SYSTEM RISER DIAGRAM
NOT TO SCALE
MECH / ELEC -109
105B
EL
RQE
MB
PT
JBPS
DPS
ACCESS
CONTROL
SYSTEM
PANEL
105A
EL
RQE
MB
PT
JBPS
DPS
102G
EL
RQE
MB
PT
JBPS
DPS
102F
EL
RQE
MB
PT
JBPS
DPS
102C
EL
RQE
MB
PT
JBPS
DPS
101D
EL
RQE
MB
PT
JBPS
DPS
101C
EL
RQE
MB
PT
JBPS
DPS
RE
NG
LE
8:0 9 A
M
- T
3.0 2 A
CC
ES
S
CO
NT
RO
L D
ET
AI
LS
.dw g
Job No.
Christopher A. Garick; FL. PE No.53924 Daniel J. White; FL. PE No.73790 Caleb W. Leonard; FL. PE No.91782
HG Engineers 142 Eglin Parkway SE Fort Walton Beach, Florida, 32548 E-mail: office@hgengineers.com Ph: 850.243.6723 Fl. Authorization No.00006680
26004 llc
D A
TE
D R
A W
N B
Y:
P R
O
JE
C T
N O
R E
VI
S
IO
N
S
S E
P T
, 2
R .E
N G
LE
C .P
A S
TO
R
IU
S
S
EP
T
FO
R
B
ID
P R O
FESS IONA L ENG
I N E
E R
CH
R
IS
TO
PHER A . GAR
ICKL I C E N S E
STATE OF
No. 53924
FLO RIDA
C R
E S
TV
IE
W , F
LO
R
ID
A
O ka lo os a C ou nt y
O
LD
B E
TH
E
L R
O A
D
Fa ci lit ie s W ar eh ou se
T3 .0
A C
C E
S S
C O
N
TR
O L
D E
TA
I P C A M E R A S Y S T E M L E G E N D
A. CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES PRIOR TO INSTALLATION. REFER TO ELECTRICAL, MECHANICAL AND PLUMBING
DRAWINGS FOR EXACT SIZE AND LOCATION OF EQUIPMENT WHICH IS FURNISHED BY OTHERS.
B. THE IP CAMERA SYSTEM AND THE ACCESS CONTROL SYSTEM INTEGRATION AND CONSTRUCTION SHALL BE PERFORMED BY THE SAME CONTRACTOR.
C. THE CONTRACTOR SHALL MEET WITH THE OWNER AND ARCHITECT TO COORDINATE CAMERA LOCATIONS PRIOR TO ROUGH-IN. ATTENTION SHALL BE GIVEN TO VIEWS RELATIVE TO OBSTRUCTIONS (TREES, GUTTER DOWNSPOUTS, COVERED WALKWAYS, LIGHT FIXTURES. ETC.).
D. THE CONTRACTOR SHALL TEST OPERATION OF EACH CAMERA AND SET THE FINAL CAMERA RESOLUTIONS, VIEWING ANGLES, FIELDS OF VIEW, LENS
SETTINGS AND ANY OTHER PERTINENT CAMERA SETTING.
E. RECORDING OF CAMERA IMAGES TO THE NETWORK VIDEO RECORDER SHALL BE MADE AT THE HIGHEST CAMERA RESOLUTION SETTINGS IN COLOR THAT AMBIENT LIGHT LEVELS ALLOW AND IN BLACK & WHITE DURING LOW LIGHT LEVELS. FRAMES PER SECOND SHALL BE AS DIRECTED BY OWNER, BUT NO
LESS THAN 12 FPS.
F. FINAL SYSTEM LABELING / NUMBERING FOR MARKING EQUIPMENT / CABLING AND PROGRAMMING SHALL BE COORDINATED WITH OWNER AND ARCHITECT.
G. A DATA CONNECTION SHALL BE PROVIDED TO THE IP SECURITY SERVER, EACH CAMERA, FLAT PANEL MONITORS, AND ANY CONTROL PANEL.
DIRECT TERMINATION NOTE
DIRECT TERMINATE A CAT 6 CABLE AT EACH SECURITY CAMERA WITH A MALE 8P8C MODULAR PLUG, PROVIDED BY THE TELECOM STRUCTURED CABLING CONTRACTOR. CABLE JACKET MUST BE EXTENDED INTO THE CONNECTOR FOR STRAIN
RELIEF.
I P C A M E R A G E N E R A L N O T E S
Set screw provided with mount
Corner Mount with access panel
Corner wall mount with Adjustment Plate and Mounting Cleat. Secure with SS fasteners.
Clear or Smoked Dome Camera
NOT TO SCALE
CORNER MOUNTED CAMERA DETAIL
SYSTEM SYMBOLS
OUTDOOR 270 DEGREE, THREE-CAMERA MULTIIMAGE, DOWNLOOK VIEW CAMERA, EQUAL TO IPRO WV-S8574L 33 MP. COLOR WHITE.
CORNER MOUNT USING IPRO WV-QSR503-W SHROUD, IPRO WV-QWL501-W WALL MOUNT AND IPRO WV-QCN500-W CORNER MOUNT
ADAPTER, COLOR WHITE. INSTALL AT 12'-0" AFF.
360 DEGREE, FOUR-CAMERA MULTIIMAGE, DOWNLOOK VIEW CAMERA, EQUAL TO IPRO WV-S4176A 12 MP, COLOR WHITE. CEILING MOUNT FOR 360 DEGREE VIEW. SUPPORT TO CEILING USING WV-QCL101-W BRACKET. INSTALL AT 12'-0" AFF.
180 DEGREE, TWO-CAMERA MULTIIMAGE, DOWNLOOK VIEW CAMERA, EQUAL TO IPRO WV-S8573L 25 MP, COLOR WHITE. WALL MOUNT
USING IPRO WV-QWL501-W WALL MOUNTING BRACKET. INSTALL AT 12'-0" AFF.C
C
C
NOT TO SCALE
PENDANT CAMERA MOUNTING DETAIL
CEILING MOUNT
DOME CAMERA
4" SQ DEEP JUNCTION BOX WITH
CONDUIT ADAPTER COVER,
ATTACH TO CEILING STRUCTURE
ROOF STRUCTURE
SURFACE MOUNT
EMT CONDUIT.
PROVIDE BUSHING OR
GROMMET AT OPENING.
INSTALL PENDANT MOUNTED
PIPE (BY E.C.) TO PROVIDE
CAMERA INSTALLATION HEIGHT
AS INDICATED ON PLANS.
IP SECURITY SYSTEM RISER DIAGRAM
NOT TO SCALE
SECURITY SERVER
SECURITY SYSTEM RISER NOTES:
POE PATCH PANEL BY STRUCTURED CABLING CONTRACTOR.
POE SWITCH PROVIDED BY OWNER INSTALLED BY STRUCTURED
CABLING CONTRACTOR.
SECURITY
SYSTEM
CONTROL
PANEL
THE IP SECURITY CAMERA SYSTEM INTEGRATOR SHALL PROVIDE A
NETWORK SERVER VIDEO RECORDER WITH i-PRO VI LOGO RACK
MOUNTED IN THE MAIN COMM ROOM WITH RAID 5 OR 6 STORAGE. HARD
DRIVES SHALL BE VIDEO SURVEILLANCE GRADE (PURPLE). THE SERVER
SHALL HAVE SUFFICIENT UNUSED HARD DRIVE SLOTS TO ALLOW AT
LEAST 100% EXPANSION OF STORAGE IN THE FUTURE, AFTER THE HARD
DRIVES FOR THIS PROJECT ARE INSTALLED. SUFFICIENT STORAGE SHALL
BE PROVIDED UNDER THIS PROJECT TO ARCHIVE 30 DAYS OF VIDEO WITH
ALL CAMERAS RECORDING AT FULL RESOLUTION IN COLOR AND AT A
MINIMUM OF 12 FRAMES PER SECOND. THE INTEGRATOR SHALL UTILIZE
H.265 SMARTCODEC WHERE FACTORY INTEGRATED INTO THE SPECIFIED
CAMERAS OR H.264 SMARTCODEC WHERE H.265 IS NOT FACTORY
INTEGRATED. SETUP TO OPTIMIZE STORAGE WITHOUT SACRIFICING
VIDEO QUALITY.
RE
NG
LE
8:0 9 A
M
- T
3.0 3 I
P
SE
CU
RI
TY
C
CT
V
DE
TA
ILS
.dw g
Job No.
Christopher A. Garick; FL. PE No.53924 Daniel J. White; FL. PE No.73790 Caleb W. Leonard; FL. PE No.91782
HG Engineers 142 Eglin Parkway SE Fort Walton Beach, Florida, 32548 E-mail: office@hgengineers.com Ph: 850.243.6723 Fl. Authorization No.00006680
26004 llc
D A
TE
D R
A W
N B
Y:
P R
O
JE
C T
N O
R E
VI
S
IO
N
S
S E
P T
, 2
R .E
N G
LE
C .P
A S
TO
R
IU
S
S
EP
T
FO
R
B
ID
P R O
FESS IONA L ENG
I N E
E R
CH
R
IS
TO
PHER A . GAR
ICKL I C E N S E
STATE OF
No. 53924
FLO RIDA
C R
E S
TV
IE
W , F
LO
R
ID
A
O ka lo os a C ou nt y
O
LD
B E
TH
E
L R
O A
D
Fa ci lit ie s W ar eh ou se
T3 .0
IP
S
E C
U R
IT
Y
C C
TV
D
E
TA
| 2026-09-14T09:45:40-0500 | |