26-Attachment S - Plans Drawings.pdf
PDF 39 MB Posted
- Solicitation number
- 25/0353
- Issued by
- Harris County, Texas
About this file
This document is a comprehensive set of engineering and design plans for the Brookglen Stormwater Detention Basin Phase 2 project, prepared by AECOM Technical Services for the Harris County Flood Control District (HCFCD). The project is located in La Porte, Texas, and is funded through multiple sources including TX-GLO CDBG-DR Contract and US-HUD CDBG-DR Contracts. The plans, dated October 9, 2025, cover 73 detailed sheets including site layouts, survey maps, construction details, traffic control plans, landscape and planting specifications, and soil boring profiles. The project involves constructing a stormwater detention basin spanning approximately 8.18 acres, with multiple compartments and associated infrastructure including spillways, water and sanitary sewer systems, and access routes.
The project is budgeted at $3,627,145 and involves complex engineering specifications including specific requirements for soil stabilization, concrete work, utility installations, and environmental considerations. The design incorporates multiple technical elements such as floatable collection structures, channel lining details, and specific provisions for tree removal and preservation. Funding sources include Community Development Block Grant - Disaster Recovery (CDBG-DR) programs from both the Texas General Land Office (GLO) and the U.S. Department of Housing and Urban Development (HUD), with specific contract identifications noted. The project is located in Harris County Precinct 2 and involves careful environmental and infrastructure planning to manage stormwater in the Brookglen area.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
KEY MAP 578 D, PCT 2
HCFCD PROJECT ID# B512-02-00-E002
LESLEY BRIONES
TOM S. RAMSEY, P.E.
ADRIAN GARCIA
RODNEY ELLIS
COUNTY JUDGE LINA HIDALGO
PCT. 1
PCT. 2 PCT. 4
PCT. 3
CHRISTINA (TINA) PETERSEN, PHD, P.E.EXECUTIVE DIRECTOR SHEET 01 OF 73
FINAL SUBMITTAL
PROJECT LOCATION
L:
\L
EG
AC
Y\
US
HO
U1
FS
1\
PR
OD
\P
RO
JE
CT
S\
_P W
D\
HA
RR
IS
C
OU
NT
Y
FL
OO
D
CO
NT
RO
L
DI
ST
RI
CT
\6
2-
BR
OO
KG
LE
NA
RE
A\
0_
CA
D_
GI
S\
0_
CA
D\
-S
HE
ET
S\
SO
UT
H_
0% _S
HE
ET
S\
CO
VE
R_
SH
EE
T-
.D
W G
E
D.
PA
NU
SK
A | S
AV
ED
: W ed ne sd ay , O cto be r 8 , 2
1:
:5
PM |
H
CF
CD
.C
TB
PL
OT
TE
D:
W ed ne sd ay
, O cto be r 8
, 2
2:
:3
PM
PROJECT
LOCATION
VICINITY MAP
PROJECT
LOCATION
PRECINCT 4
PRECINCT 3
PRECINCT 1
PRECINCT 2
BROOKGLEN STORMWATER DETENTION BASIN
PHASE 2
JOB ID:
TX-GLO CDBG-DR CONTRACT ID: 24-033-000-E072
US-HUD CDBG-DR CONTRACT ID: B-17-DM-48-0001; B-18-DP-48-0001
Issued for Bidding 11/07/2025 25-0353
AutoCAD SHX Text
ONE-CALL NOTIFICATION SYSTEM
AutoCAD SHX Text
CALL BEFORE YOU DIG!!!
AutoCAD SHX Text
(713) 223-4567
AutoCAD SHX Text (New Statewide Number Outside Houston)
AutoCAD SHX Text 1-800-545-6005
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text S
AutoCAD SHX Text
EDWARD J. PANUSKA III
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text X
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text 129856
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text
OCTOBER 9, 2025
AutoCAD SHX Text
SOMERTON DR.
AutoCAD SHX Text
OAKHAVEN RD.
AutoCAD SHX Text
LUELLA BLVD.
AutoCAD SHX Text
SPENCER HWY
AutoCAD SHX Text
GLADWYNE LN.
AutoCAD SHX Text
ASHWYNE LN.
AutoCAD SHX Text
FERN ROCK DR.
AutoCAD SHX Text p
AutoCAD SHX Text p
AutoCAD SHX Text p
AutoCAD SHX Text p
AutoCAD SHX Text p
AutoCAD SHX Text p
AutoCAD SHX Text o
AutoCAD SHX Text o
AutoCAD SHX Text o
AutoCAD SHX Text o
AutoCAD SHX Text o
AutoCAD SHX Text o
AutoCAD SHX Text p
AutoCAD SHX Text p
AutoCAD SHX Text p
AutoCAD SHX Text o
AutoCAD SHX Text o
AutoCAD SHX Text p
AutoCAD SHX Text p
AutoCAD SHX Text o
AutoCAD SHX Text
HARDY TOLL ROAD
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
Houston, Texas 77092 9900 Northwest Freeway
SHEET NUMBER
DATE: 09-Oct-2025
PR
EP
AR
ED
SCALE: AS -NOTED
OF
H C
FC
D
P R
O
JE
C T
ID
B5
-0 2-
-E
BR
O
O
KG
LE
N
S
TO
R M
W
AT
ER
D
ET
EN
TI
O
N B
AS
IN
PH
AS
E
C H
EC
KE
D
AP
PR
O
VE
D
:AB C
XO
EJ
P
AECOM Technical Services, Inc.
800 Gessner Road, Suite 1200
Houston, Texas 77024 TBPE Reg. No. F-3580
R
EV
D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
IN
D
EX
O
F D
R
AW
IN
G
S
L:
\L
EG
AC
Y\ U
SH
O
U 1F
S0
\P R
O D
\P R
O
JE
C
TS
PW
D \H
AR
R
IS
C
O U
N
TY
F
LO
O D
C O
N
TR
O L
D
IS
TR
IC
T\
-B
R O
O
KG
LE
N
AR
EA
\9
_C
AD
_G
IS
\9
_C
AD
\2 0-
SH
EE
TS
\S
O U
TH
_1
_S H
EE
TS
\D R
AW
IN
G
-IN
D
EX
-6
2.
D
W G
E
D .P
AN
U
SK
A
S
AV
ED
M on da y, O ct ob er
, 2
:1 0:
A
M
H C
FC
D
.C
P
LO
TT
ED
W ed ne sd ay , O ct ob er
:3 3:
P
M
INDEX OF DRAWINGS
SHEET NO. SHEET TILE REVISION
GENERAL
01 COVER SHEET
02 INDEX OF DRAWINGS
03 HCFCD EXPRESS REVIEW SHEET
04 GENERAL NOTES 1 OF 5
05 GENERAL NOTES 2 OF 5
06 GENERAL NOTES 3 OF 5
07 GENERAL NOTES 4 OF 5
08 GENERAL NOTES 5 OF 5
09 LEGENDS & ABBREVIATIONS
10 SURVEY CONTROL MAP 1 OF 5
11 SURVEY CONTROL MAP 2 OF 5
12 SURVEY CONTROL MAP 3 OF 5
13 SURVEY CONTROL MAP 4 OF 5
14 SURVEY CONTROL MAP 5 OF 5
15 SWINGTIES 1 OF 5
16 SWINGTIES 2 OF 5
17 SWINGTIES 3 OF 5
18 SWINGTIES 4 OF 5
19 SWINGTIES 5 OF 5
20 OVERALL PROJECT LAYOUT
21 ACCESS ROUTE AND CONSTRUCTION ACCESS
PROPOSED COMPARTMENT PLANS
22 EXISTING RIGHT OF WAY 1 OF 2
23 EXISTING RIGHT OF WAY 2 OF 2
24 EXIST CONDITIONS AND DEMOLITION PLAN 1 OF 2
25 EXIST CONDITIONS AND DEMOLITION PLAN 2 OF 2
26 PROPOSED RIGHT OF WAY 1 OF 2
27 PROPOSED RIGHT OF WAY 2 OF 2
28 EXCAVATION PLAN
29 COORDINATE LAYOUT PLAN 1 OF 2
30 COORDINATE LAYOUT PLAN 2 OF 2
31 COORDINATE POINT TABLE
32 BASIN CROSS SECTIONS 1 OF 3
33 BASIN CROSS SECTIONS 2 OF 3
34 BASIN CROSS SECTIONS 3 OF 3
35 WEST COMPARTMENT SPILLWAY
36 NORTH COMPARTMENT SPILLWAY
37 WATER, SANITARY, STORM SEWER AND PAVING LAYOUT 1 OF 2
38 WATER, SANITARY, STORM SEWER AND PAVING LAYOUT 2 OF 2
INDEX OF DRAWINGS
SHEET NO. SHEET TILE REVISION
39 ASHWYNE LN PLAN AND PROFILE STA 1+00 TO 6+20
40 ASHWYNE LN PLAN AND PROFILE STA 6+20 TO 10+60
41 SOUTH COMPARTMENT OUTFALL PLAN AND PROFILE STA 1+00 TO 5+60
42 SOUTH COMPARTMENT OUTFALL PLAN AND PROFILE STA 5+60 TO 10+20
43 SOUTH COMPARTMENT OUTFALL PLAN AND PROFILE STA 10+20 TO 14+80
44 STORM WATER POLLUTION PREVENTION PLAN 1 OF 2
45 STORM WATER POLLUTION PREVENTION PLAN 2 OF 2
DETAILS
46 MISCELLANEOUS DETAILS 1 OF 1
47 STRUCTURAL DETAILS 1 OF 1
48 INTERCEPTOR STRUCTURE AND CONCRETE PILOT DETAILS
49 STORM SEWER AND RIPRAP DETAILS
50 CONCRETE CHANNEL LINING DETAILS
51 FLOATABLE COLLECTION STRUCTURE DETAILS 1 OF 3
52 FLOATABLE COLLECTION STRUCTURE DETAILS 2 OF 3
53 FLOATABLE COLLECTION STRUCTURE DETAILS 3 OF 3
54 HCFCD SWPPP DETAILS
55 STANDARD CIVIL DETAILS 1 OF 11
56 STANDARD CIVIL DETAILS 2 OF 11
57 STANDARD CIVIL DETAILS 3 OF 11
58 STANDARD CIVIL DETAILS 4 OF 11
59 STANDARD CIVIL DETAILS 5 OF 11
60 STANDARD CIVIL DETAILS 6 OF 11
61 STANDARD CIVIL DETAILS 7 OF 11
62 STANDARD CIVIL DETAILS 8 OF 11
63 STANDARD CIVIL DETAILS 9 OF 11
64 STANDARD CIVIL DETAILS 10 OF 11
65 STANDARD CIVIL DETAILS 11 OF 11
66 LANDSCAPE AND PLANTING 1 OF 2
67 LANDSCAPE AND PLANTING 2 OF 2
68 TRAFFIC CONTROL PLAN PROJECT APPROACH SIGNAGE
69 TRAFFIC CONTROL DETAILS 1 OF 3
70 TRAFFIC CONTROL DETAILS 2 OF 3
71 TRAFFIC CONTROL DETAILS 3 OF 3
72 SOIL BORING PROFILES 1 OF 2
73 SOIL BORING PROFILES 2 OF 2
AutoCAD SHX Text 10/09/2025
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text S
AutoCAD SHX Text
EDWARD J. PANUSKA III
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text X
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text 129856
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text E
D
578D
8831 OAKHAVEN ROAD, LA PORTE, TX 77571
LA PORTE
B112-00-00
AECOM
POST-USACE VERIFIED WATERS OF UNITED STATES DELINEATION REPORT
SEPTEMBER 2021
47 - 53
22 - 23, 26 - 27
B112-00-00
BROOKGLEN STORMWATER DETENTION BASIN
PHASE 2
8831 OAKHAVEN ROAD, LA PORTE, TX 77571
03 73
1021820000001 1021820000002 1021820000003 1021820000004 1021820000005 1021820000006 1021820000007 1021820000008 1021820000009 1021820000010 1021820000011 1021820000012 1021820000013 1021820000014 1021820000015 1021820000016 1021820000017 1021820000018 1021820000019 1021820000020 1021820000021 1021820000022 1021820000023 1021820000024 1021820000025 1021820000026 1021820000027 1021820000028 1021820000029 1021820000030 1021820000031 1021820000032 1021750000065 1021750000066 1021750000067 1021750000068 1021750000069 1021750000070
ARMAND BAYOU
HCFCD
48201C0940M 1/6/2017
22.0 FT
22.0 FT
01 73
44, 45, AND 54
8.18AC
BROOKGLEN
SEE SURVEY SHEETS 10-14
SOMERTON DRIVE, ASHWYNE LANE, GLADWYNE LANE
BLOCK 1 BROOKGLEN SEC. 1 VOL. 153, PG. 99 M.R.H.C., TX
BLOCK 11 BROOKGLEN SEC. 2 VOL. 167, PG. 109 M.R.H.C., TX
BLOCK 11 BROOKGLEN SEC. 2 VOL. 167, PG. 109 M.R.H.C., TX
10/9/25
SEE SHEETS 12 - 14
ENGINEER'S CERTIFICATION
4. FLOOD PLAIN STATUS
HARRIS COUNTY
FLOOD CONTROL DISTRICT
REVIEW SHEET
HARRIS COUNTY FLOOD CONTROL DISTRICT
2. SITE DETENTION DRAINAGE
R E V I S I O N S
(2001 ADJ.)
5. WORK IN HCFCD RIGHT-OF-WAY
1. PROPERTY DESCRIPTION
OFFSITE SHEET FLOW: (100 YEAR)
OFFSITE SHEET FLOW MAPPING, TOTAL DISCHARGE CALCULATIONS, AND
DESIGN ACCOMODATIONS ARE SHOWN ON SHEET _____ OR, AS PRESENTED
IN THE APPROVED DRAINAGE STUDY ENTITLED _________________________.
TOTAL ACREAGE = _____
TOTAL DISCHARGE = _____
NOTE: ALL OFFSITE SHEET FLOW FROM ADJACENT PROPERTIES MUST BE
IDENTIFIED AND PROPERLY ACCOUNTED FOR IN THE PROJECT. THE SIGNING
ENGINEER HEREBY CERTIFIES THAT THESE AREAS HAVE BEEN ADDRESSED.
HCFCD SIGNATURE BLOCK
3. SWQ DISCHARGE INTO FCD FACILITY
6. REPORTS/AGREEMENTS
FOR PROJECTS LOCATED IN ANY FLOODPLAIN
Development constructed or placed in accordance with these plans will comply with all provisions of the designated Floodplain Administrator.
No net fill is allowed in the flood plain and no fill is allowed in the floodway.
HARRIS COUNTY FLOOD CONTROL DISTRICT
22 - 43
N/A N/A
N/A
36- INCH
4' X 2'
N/A
SWG-2021-00093 (NWP 3 a/c)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
12.55 31.63
2969.72 4215.83
4134.07
20.35
N/A
N/A
6.19
2902.41
16.18
N/A
N/A
5.57
9.50
131.4
BROOKGLEN STORMWATER DETENTION BASINS, HCFCD PROJECT ID# B512-02-E001,
FINAL DRAINAGE REPORT
B512-02-00-E001
AECOM TECHNICAL SERVICES, INC.
GEOTECHNICAL INVESTIGATION, BROOKGLEN DETENTION BASINS, HCFCD PROJECT ID #
B512-02-E001, HARRIS COUNTY PRECINCT 2, HARRIS COUNTY, TEXAS, REPORT NO. G118-20
B512-02-00-E001
AVILES ENGINEERING CORPORATION
12/15/2020
N/A
22.0
49.5244.55
BASIN LOWEST ELEVATION = 10.30,
BERM ELEVATION = 20.70
N/A N/A
B512-02-00-E002
20.2 FT
PROPOSED DETENSION BASIN
04/04/2023
1,427
45,157
$3,627,145
AutoCAD SHX Text
I, , A LICENSED PROFESSIONAL ENGINEER IN THE STATE OF TEXAS, DO HEREBY CERTIFY
AutoCAD SHX Text THAT THE INFORMATION PRESENTED ON THIS SHEET IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE
AutoCAD SHX Text AND THAT I AM NOT VIOLATING ANY PROVISION OF THE CURRENT TEXAS ENGINEERING PRACTICE ACT AND RULES
AutoCAD SHX Text
CONCERNING THE PRACTICE OF ENGINEERING AND PROFESSIONAL ENGINEERING LICENSURE.
AutoCAD SHX Text
THE COMPLETED PROJECT CONSISTS OF DRAWING SHEETS THRU .
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
SIGNATURE
AutoCAD SHX Text ANY VIOLATIONS WILL BE FORWARDED TO THE HARRIS COUNTY DISTRICT ATTORNEY'S OFFICE FOR PROSECUTION.
AutoCAD SHX Text
FIRM PANEL(S) FOR PROPERTY:
AutoCAD SHX Text
FIRM PANEL(S) DATE:
AutoCAD SHX Text
STATUS OF PROPERTY ON MAP
AutoCAD SHX Text
ENTIRELY LOCATED IN UNSHADED ZONE "X"
AutoCAD SHX Text
LOCATED PARTIALLY OR ENTIRELY IN ANY "A" ZONE OR SHADED ZONE "X",
AutoCAD SHX Text
ELEVATION INFORMATION
AutoCAD SHX Text
BENCHMARK USED
AutoCAD SHX Text
DESCRIPTION OF BENCHMARK INCLUDING ELEVATION, DATUM AND
AutoCAD SHX Text %%uII. FLOOD PLAIN DETERMINATION BASED ON GROUND ELEVATION
AutoCAD SHX Text
PROPERTY LIES ENTIRELY ABOVE THE BASE FLOOD LEVEL
AutoCAD SHX Text
PROPERTY LIES PARTIALLY OR ENTIRELY BELOW THE BASE FLOOD
AutoCAD SHX Text
AND IN SHADED ZONE "X"
AutoCAD SHX Text
LEVEL
AutoCAD SHX Text
YEAR OF ADJUSTMENT
AutoCAD SHX Text
HARRIS COUNTY FLOODPLAIN REFERENCE MARK
AutoCAD SHX Text
HARRIS-GALVESTON COASTAL SUBSIDENCE DISTRICT
AutoCAD SHX Text
SHEET NUMBER ___ OF ___
AutoCAD SHX Text
HARRIS COUNTY FLOOD CONTROL PROJECT NO.
AutoCAD SHX Text WAS ACCEPTED BY HARRIS COUNTY FLOOD CONTROL DISTRICT FOR THE PURPOSES LISTED BELOW:
AutoCAD SHX Text THE PROJECT WAS REVIEWED, HOWEVER, THIS DOES NOT MEAN THE ENTIRE PROJECT, INCLUDING ALL SUPPORTING DATA
AutoCAD SHX Text AND CALCULATIONS HAVE BEEN COMPLETELY CHECKED AND VERIFIED. THESE DRAWINGS ARE SIGNED, DATED AND SEALED
AutoCAD SHX Text BY A PROFESSIONAL ENGINEER LICENSED TO PRACTICE IN THE STATE OF TEXAS, WHICH THEREFORE CONVEYS THE ENGINEER'S
AutoCAD SHX Text RESPONSIBILITY AND ACCOUNTABILITY. THIS DOES NOT RELIEVE ANY PARTY FROM COMPLYING WITH APPROPRIATE FEDERAL, STATE
AutoCAD SHX Text AND LOCAL ENVIRONMENTAL RULES, LAWS, AND REGULATIONS AND ANY OTHER LEGALLY ADOPTED REGULATION OR ORDINANCE
AutoCAD SHX Text UNTIL SUCH SIGNATURES ARE OBTAINED. PLAN APPROVAL EXPIRATION TO BE IN ACCORDANCE WITH LOCAL GOVERNEMENT CODE CH. 245.
AutoCAD SHX Text %%uI. GENERAL INFORMATION
AutoCAD SHX Text
BENCHMARK (FOR COASTAL AREAS)
AutoCAD SHX Text
DELINEATE FLOODPLAIN BOUNDARY ON CONSTRUCTION DRAWINGS
AutoCAD SHX Text %%uIII. FLOODPLAIN STORAGE SUMMARY
AutoCAD SHX Text
A. TOTAL VOLUME OF MATERIAL PROPOSED TO BE MOVED OR PLACED WITHIN
AutoCAD SHX Text
(APPLIES ONLY TO PORTION OF LAND LOCATED WITHIN FEMA REGULATORY FLOODPLAIN).
AutoCAD SHX Text
THE FIRM DELINEATED FLOODPLAIN (FILL, BASE, CONCRETE, ASPHALT, ETC.):
AutoCAD SHX Text
BELOW 0.2%%% BASE FLOOD ELEVATION
AutoCAD SHX Text
(2001 ADJ.)
AutoCAD SHX Text
CUBIC YARDS
AutoCAD SHX Text
DELINEATED FLOODPLAIN:
AutoCAD SHX Text
B. TOTAL VOLUME OF MATERIAL PROPOSED TO BE REMOVED FROM THE FIRM
AutoCAD SHX Text
(2001 ADJ.)
AutoCAD SHX Text
CUBIC YARDS
AutoCAD SHX Text
SITE REMOVED FROM FLOODPLAIN BY LOMR, LOMR-F, LOMA
AutoCAD SHX Text
CASE NO.__________ REVISED FLOODPLAIN IS SHOWN ON SHEET____
AutoCAD SHX Text
BY
AutoCAD SHX Text
INTERPOSE NO OBJECTION
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
BY
AutoCAD SHX Text
FOR ITEMS LOCATED OUTSIDE OF HCFCD RIGHT-OF-WAY
AutoCAD SHX Text
FOR ITEMS LOCATED WITHIN EXISTING HCFCD RIGHT-OF-WAY
AutoCAD SHX Text
BY
AutoCAD SHX Text
FOR ITEMS LOCATED WITHIN PROPOSED HCFCD RIGHT-OF-WAY
AutoCAD SHX Text
STORMWATER DRAINAGE DESIGN REPORT
AutoCAD SHX Text
REPORT TITLE __________________________________________________________
AutoCAD SHX Text
REPORT ACCEPTANCE DATE _____________________
AutoCAD SHX Text
HCFCD PROJECT #______________
AutoCAD SHX Text
PROJECT NAME:
AutoCAD SHX Text
APPROVED:
AutoCAD SHX Text
VERSION 1.0 OCTOBER 2019
AutoCAD SHX Text RELATED TO LAND DEVELOPMENT. IF THE CITY SIGNATURES ARE REQUIRED BY ORDINANCE, COUNTY PERMITS WILL NOT BE ISSUED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
H.C.F.C.D APPROVED DATE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
%%UI. TYPE OF WORK TO BE PERFORMED IN HCFCD HCFCD ROW
AutoCAD SHX Text
%%UII. USACE ENVIRONMENTAL PERMIT
AutoCAD SHX Text
%%UIII. REFERENCE / BASIS OF DETERMINATION
AutoCAD SHX Text
I. - III. REQUIRED ON PROJECTS WITH WORK IN A HCFCD CHANNEL.
AutoCAD SHX Text
%%UNOTES:
AutoCAD SHX Text
PLEASE REFERENCE SECTION 17 OF THE FLOOD CONTROL DISTRICT
AutoCAD SHX Text
POLICY, CRITERIA, AND PROCEDURE MANUAL FOR MORE INFORMATION.
AutoCAD SHX Text
(DRAINAGE LAYOUT PG. NO._____)
AutoCAD SHX Text
(1%%% BASE FLOOD LEVEL______)
AutoCAD SHX Text
P.E. INITIAL
AutoCAD SHX Text
C. FILL AREA & VOLUME CALCULATIONS ARE SHOWN ON SHEET
AutoCAD SHX Text
ADDRESS:
AutoCAD SHX Text
PLANS HAVE BEEN APPROVED BY HARRIS COUNTY FLOOD CONTROL.
AutoCAD SHX Text
NOTE: REVISION BLOCK IS TO BE USED ONLY FOR CHANGES MADE %%UAFTER%%U
AutoCAD SHX Text
GEOTECHNICAL INVESTIGATION REPORT
AutoCAD SHX Text
(0.2%%% BASE FLOOD LEVEL_____)
AutoCAD SHX Text
BELOW 0.2%%% BASE FLOOD ELEVATION
AutoCAD SHX Text
PUBLIC
AutoCAD SHX Text
PUBLIC & PRIVATE
AutoCAD SHX Text
NONE
AutoCAD SHX Text
RECORDED PLAT / REPLAT
AutoCAD SHX Text
PROPOSED PLAT / REPLAT
AutoCAD SHX Text
%%UI. LOCATION INFORMATION
AutoCAD SHX Text
%%UIV. JURISDICTIONS
AutoCAD SHX Text
A. ACREAGE:
AutoCAD SHX Text
A. SUBDIVISION PLAT
AutoCAD SHX Text
PRIVATE
AutoCAD SHX Text
SURVEY & ABSTRACT:
AutoCAD SHX Text
C. ADJACENT ROADS:
AutoCAD SHX Text
%%UII. LEGAL DESCRIPTION
AutoCAD SHX Text
PLAT NAME:
AutoCAD SHX Text
B. STREETS PROPOSED
AutoCAD SHX Text
ETJ, CITY OF HOUSTON
AutoCAD SHX Text
NO ETJ
AutoCAD SHX Text
ETJ, CITY OF
AutoCAD SHX Text
CITY OF
AutoCAD SHX Text
%%UIII. PLATTING
AutoCAD SHX Text
B. SUBDIVISION:
AutoCAD SHX Text
%%UV. HCAD ACCOUNT NOS. (ALL)
AutoCAD SHX Text
B. KEY MAP:
AutoCAD SHX Text
A. HARRIS COUNTY COMMISSIONER'S PRECINCT:
AutoCAD SHX Text
C. ADDRESS:
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
UTILITY DISTRICT (NAME)
AutoCAD SHX Text
RE-DEVELOPMENT AREA (AMOUNT INCREASED IMPERVIOUS AREA):
AutoCAD SHX Text
NEW DEVELOPMENT AREA:
AutoCAD SHX Text
%%UI. PROPOSED DRAINAGE AREA
AutoCAD SHX Text
%%UII. METHODOLOGY
AutoCAD SHX Text
%%UIII. DETENTION VOLUME & OUTFALL
AutoCAD SHX Text
OUTFALL TO:
AutoCAD SHX Text
LOW IMPACT DEVELOPMENT (LID)
AutoCAD SHX Text
OTHER (OWNER & OPERATOR)
AutoCAD SHX Text
%%UVII. DETENTION PROVIDED BY
AutoCAD SHX Text
REGIONAL DETENTION BASIN SYSTEM (APPROVED H.C. PRJ NO.): ________
AutoCAD SHX Text
BY
AutoCAD SHX Text
FINAL PERMITTING BY OTHERS
AutoCAD SHX Text
NO REVIEW REQUIRED:
AutoCAD SHX Text
ADDITIONAL COMMENTS:
AutoCAD SHX Text
DETENTION BASIN MAINTAINED BY: _____________________________
AutoCAD SHX Text
HCFCD PCPM DETENTION METHOD USED:
AutoCAD SHX Text
METHOD 1 (LESS THAN 20 ACRES)
AutoCAD SHX Text
METHOD 3 (GREATER THAN 640 ACRES)
AutoCAD SHX Text
METHOD 2 (20 ACRES TO 640 ACRES)
AutoCAD SHX Text
D. ADDITIONAL CRITERIA FOR PUMPED DETENTION BASINS
AutoCAD SHX Text %%UI. SWPPP: CONSTRUCTION MEASURES. (Must complete)
AutoCAD SHX Text
OTHER(S):
AutoCAD SHX Text
DISTURBS >1AC. SITE PLAN & DETAILS ON SHEET(S)
AutoCAD SHX Text %%U*II. APPLICABILITY FOR PERMANENT FEATURES. (Must complete)
AutoCAD SHX Text
%%UIII. PERMANENT SWQ FEATURES.%%U (COMPLETE IF NOT EXEMPT)
AutoCAD SHX Text
SHEET(S)
AutoCAD SHX Text
VEGETATIVE CONTROLS USED: (FILTER STRIP, GRASSY SWALE,
AutoCAD SHX Text
PROJECT'S DRAINAGE TIES DIRECTLY INTO AN EXISTING DRAINAGE
AutoCAD SHX Text
SITE PLAN ON SHEET(S)
AutoCAD SHX Text
POND STRUCTURE USED (WET, DRY, WETLANDS) DETAILS AND
AutoCAD SHX Text
CALCULATIONS APPEAR ON SHEET(S)
AutoCAD SHX Text
PROJECT DOES NOT MEET THE DEFINITION OF SIGNIFICANT
AutoCAD SHX Text
STORMWATER QUALITY PERMIT REQUIREMENT IS COVERED BY AN
AutoCAD SHX Text
EXISTING SWQMP WITHIN PROJECT TITLE:
AutoCAD SHX Text
HYDRODYNAMIC TYPE SEPARATOR MODEL:
AutoCAD SHX Text REDEVELOPMENT (Part A,Sec. 2.39 of Regulations of Harris County, AutoCAD SHX Text
PROJECT IS ON A PARCEL (A COMMON PLAN OF DEVELOPMENT)
AutoCAD SHX Text
(FOR VERIFICATION: PROVIDE ORIGINAL DRAINAGE AREA MAP
AutoCAD SHX Text
PROJECT'S SWQ REQUIREMENTS FALL WITHIN THE JURISDICTION OF:
AutoCAD SHX Text HARRIS COUNTY PROJECT No & SWQ PERMIT No.
AutoCAD SHX Text
EXEMPT NEW DEVELOPMENT:
AutoCAD SHX Text
EXEMPT REDEVELOPMENT:
AutoCAD SHX Text
EXEMPT GRANDFATHERED:
AutoCAD SHX Text
%%UGENERAL:
AutoCAD SHX Text
DISTURBS <1AC. N/A
AutoCAD SHX Text
%%USTORMWATER QUALITY MANAGEMENT PLAN:
AutoCAD SHX Text LESS THAN 5 ACRES. (Must be verified with plat)
AutoCAD SHX Text
SYSTEM PRIOR TO OCTOBER 1, 2001.
AutoCAD SHX Text Texas for Stormwater Quality Management)
AutoCAD SHX Text
INCLUDING CALCULATIONS)
AutoCAD SHX Text
URBAN FORESTRY DETAILS AND CALCULATIONS APPEAR ON
AutoCAD SHX Text
%%UV. DETENTION PROVIDED IN OTHER PLANS:
AutoCAD SHX Text
%%UI. HCFCD ACCEPTED REPORTS (ALL)
AutoCAD SHX Text %%UII. AGREEMENT TYPE & No.;
AutoCAD SHX Text
HCFCD MAINTENANCE
AutoCAD SHX Text
OTHER
AutoCAD SHX Text
TURF ESTABLISHMENT
AutoCAD SHX Text
INTERLOCAL (ILA):
AutoCAD SHX Text
ENGINEERING FIRM _________________________________________
AutoCAD SHX Text
AutoCAD SHX Text
REPORT TITLE __________________________________________________________
AutoCAD SHX Text
REPORT ACCEPTANCE DATE _____________________
AutoCAD SHX Text
HCFCD PROJECT #______________
AutoCAD SHX Text
ENGINEERING FIRM _________________________________________
AutoCAD SHX Text
AutoCAD SHX Text
A. BOND/NOTIFICATION INFORMATION
AutoCAD SHX Text
HCFCD APPROVED VARIANCE
AutoCAD SHX Text
DESCRIPTION OF VARIANCE _________________________________________________
AutoCAD SHX Text
VARIANCE ACCEPTANCE DATE _____________________
AutoCAD SHX Text
DOCUMENT ID #______________
AutoCAD SHX Text
AutoCAD SHX Text
%%UVI. FLOW RESTRICTOR SIZE
AutoCAD SHX Text
OUTFALL PIPE SIZE:
AutoCAD SHX Text
RESTRICTOR PIPE SIZE:
AutoCAD SHX Text
AutoCAD SHX Text
%%UIV. HCFCD STANDARD NOTES%%U: SEE SHEET _____ OF THESE PLANS.
AutoCAD SHX Text
%%UV. HCFCD STANDARD DETAILS%%U: SEE SHEET _____ OF THESE PLANS.
AutoCAD SHX Text
%%UVI. HCFCD ACCESS PLAN%%U: SEE SHEET %%U %%U OF THESE PLANS.
AutoCAD SHX Text
RESTRICTOR PLATE DIMENSION:
AutoCAD SHX Text HCFCD PROJECT No.
AutoCAD SHX Text
PLAN TITLE
AutoCAD SHX Text
DETENTION POND SERVICE AREA MAP IS PROVIDED ON SHEET
AutoCAD SHX Text
DATE SIGNED BY HCFCD:
AutoCAD SHX Text VOLUME OF PUMPED 1%%% EXCEEDANCE STORAGE VOLUME = _______ ACFT _____ %%% OF TOTAL VOLUME
AutoCAD SHX Text
MAXIMUM DESIGN OUTFLOW VELOCITY INTO HCFCD CHANNEL = ____________ FT/SEC
AutoCAD SHX Text DRAIN TIME FOR BASIN = _______ HOURS BASED ON ______________________HEAD CONDITIONS
AutoCAD SHX Text
HCFCD WATERSHED
AutoCAD SHX Text
NUMBER OF OUTFALLS
AutoCAD SHX Text HCFCD UNIT No.
AutoCAD SHX Text
UTILITY CROSSING
AutoCAD SHX Text
ROADWAY BRIDGE/CULVERT CROSSING
AutoCAD SHX Text
REHABILITATION OF CHANNEL
AutoCAD SHX Text
FILL ACTIVITY
AutoCAD SHX Text
MAINTENANCE
AutoCAD SHX Text
TEMPORARY CROSSING
AutoCAD SHX Text
OTHER
AutoCAD SHX Text
TRAIL (LENGTH)
AutoCAD SHX Text
COST OF WORK IN HCFCD ROW
AutoCAD SHX Text
US ARMY CORPS OF ENGINEERS NATIONWIDE
AutoCAD SHX Text
PERMIT NUMBER(S)
AutoCAD SHX Text
US ARMY CORPS OF ENGINEERS INDIVIDUAL PERMITS
AutoCAD SHX Text
OTHER
AutoCAD SHX Text
NO PERMITS REQUIRED
AutoCAD SHX Text
EXPLAIN:
AutoCAD SHX Text
ENVIRONMENTAL CONSULTANT REPORT
AutoCAD SHX Text
BY
AutoCAD SHX Text
REPORT TITLE
AutoCAD SHX Text
REPORT DATE
AutoCAD SHX Text
OTHER
AutoCAD SHX Text
%%UVII. REFER TO THE FOLLOWING PLAN SHEETS:%%U %%U
AutoCAD SHX Text
FOR EXISTING AND PROPOSED RIGHT(S) OF WAY INCLUDING DELINEATION AND
AutoCAD SHX Text
RECORDING INFORMATION PER HCFCD POLICY, CRITERIA, & PROCEDURE MANUAL
AutoCAD SHX Text (i.e., DRAINAGE EASEMENT, FEE STRIP, ETC.) AND GRANTEE (e.g. COH, HCFCD, PUBLIC, TXDOT, ETC.)
AutoCAD SHX Text
ENGINEERING FIRM
AutoCAD SHX Text
.65, H.C.F.C.D. CHANNEL, (H.C.F.C.D. UNIT NO.)
AutoCAD SHX Text
OTHER
AutoCAD SHX Text
.75, EXISTING STORM SEWER (OWNER & OPERATOR)
AutoCAD SHX Text
1.00, ROADSIDE DITCH, (OWNER & ROAD NAME)
AutoCAD SHX Text
%%UIV. STORMWATER DETENTION BASIN INFORMATION
AutoCAD SHX Text
A. HCFCD PCPM SUMMARY TABLE SEE SHEET _____ OF THESE PLANS.
AutoCAD SHX Text
STORM EVENT
AutoCAD SHX Text
DETENTION BASIN SERVICE AREA
AutoCAD SHX Text
DESIGN WATER SURFACE ELEVATION
AutoCAD SHX Text
(2-YEAR)
AutoCAD SHX Text
50%%% EXCEEDANCE
AutoCAD SHX Text
(10-YEAR)
AutoCAD SHX Text
10%%% EXCEEDANCE
AutoCAD SHX Text
(100-YEAR)
AutoCAD SHX Text
1%%% EXCEEDANCE
AutoCAD SHX Text acres
AutoCAD SHX Text MINIMUM STORAGE REQUIRED (ac-ft)
AutoCAD SHX Text DETENTION STORAGE PROVIDED (ac-ft)
AutoCAD SHX Text STORAGE RATE PROVIDED (ac-ft/ac)
AutoCAD SHX Text DRAIN TIME - 1%%% ONLY (hours)
AutoCAD SHX Text
METHOD/DESCRIPTION
AutoCAD SHX Text
INCLUDING CALCULATIONS)
AutoCAD SHX Text
B. DETENTION BASIN TO BE MAINTAINED BY ___________________
AutoCAD SHX Text
C. DETENTION SERVICE AREA MAP ON SHEET _______
AutoCAD SHX Text
MAXIMUM ALLOWABLE OUTFLOW AT STREAM B112-02-00 (PRE-DEVELOPMENT PEAK FLOW)
AutoCAD SHX Text
MAXIMUM OUTFLOW PROVIDED (PEAK FLOW FROM BASIN, INCLUDES CULVERT AND WEIR FLOWS)
AutoCAD SHX Text
LOWEST NATURAL/FINISHED GROUND OR FINISHED FLOOR ELEVATION ESTIMATE
AutoCAD SHX Text OUTFLOW VELOCITY INTO CHANNEL (ft/sec)
AutoCAD SHX Text
EMERGENCY OVERFLOW (TYPE, SIZE, ELEVATION, ETC.)
AutoCAD SHX Text
PROPOSED-CONDITIONS FLOW AT STREAM B112-02-00
AutoCAD SHX Text
TRAPEZOIDAL SPILLWAY. ELEVATION = 17.50'. BOTTOM WIDTH = 20.0'. SIDE SLOPE = 4:1
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text S
AutoCAD SHX Text
EDWARD J. PANUSKA III
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text X
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text 129856
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text E
HCFCD GENERAL NOTES: (APPLICABLE WITHIN HCFCD ROW)
1. FENCES AND/OR OTHER ENCROACHMENTS IN THE HCFCD
RIGHT-OF-WAY ARE NOT TO BE REMOVED UNLESS OTHERWISE STATED
ON THE PLANS. IN CASES WHERE FENCE REMOVAL IS INDICATED ON
THE PLANS, THE FENCE SHALL BE REMOVED AND PLACED NEATLY ON
THE ADJACENT PROPERTY AT THE START OF CONSTRUCTION. WHERE
THERE IS NOT A SEPARATE ITEM LISTED ON THE UNIT PRICE
SCHEDULE, THE ENCROACHMENT REMOVAL IS INCIDENTAL TO SITE
PREPARATION AND RESTORATION.
2. DO NOT ENTER PRIVATE PROPERTY WITHOUT PROPER WRITTEN
AUTHORIZATION FROM THE OWNER. PROVIDE COPY OF WRITTEN
PERMISSION TO HCFCD.
3. STRIP VEGETATION AND TOPSOIL AND STOCKPILE FOR REUSE ONSITE.
MATERIAL FOUND UNACCEPTABLE BY THE ENGINEER WILL BE
REMOVED AND PAID AS EXCAVATION AND OFFSITE DISPOSAL. NO
SEPARATE MEASUREMENT AND PAYMENT WILL BE MADE FOR
STRIPPING, STOCKPILING AND PLACING ON-SITE TOPSOIL. THE COST
FOR THIS WORK WILL BE INCIDENTAL TO RELATED PAY ITEMS UNDER
SPECIFICATION SECTION NUMBER 02315 LISTED ON THE UNIT PRICE
SCHEDULE.
4. RIPRAP AND GRANULAR FILL MATERIAL REMOVED DURING
EXCAVATION, MEETING SPECIFICATION SECTION NUMBER 02378, SHALL
BE REUSED AS DIRECTED BY THE ENGINEER. REUSED MATERIAL WILL
BE MEASURED AND PAID FOR AS EXCAVATION AND ON-SITE FILL UNDER
SPECIFICATION NUMBER 02315. NO SEPARATE MEASUREMENT OR
PAYMENT WILL BE MADE FOR PROCESSING, HANDLING, STOCKPILING,
AND PLACING MATERIAL FOUND TO BE ACCEPTABLE FOR REUSE. UPON
APPROVAL OF THE ENGINEER, DISPOSAL OF NONCONFORMING RIPRAP
AND GRANULAR FILL MATERIAL WILL BE MEASURED AND PAID FOR AS
REMOVE AND DISPOSE OF CONCRETE RUBBLE UNDER SPECIFICATION
SECTION NUMBER 02120, MATERIAL DISPOSAL.
5. THE LOCATION AND GRADE OF THE BACKSLOPE INTERCEPTOR
STRUCTURES AND SWALES MAY BE ADJUSTED IN THE FIELD BY THE
ENGINEER AT THE TIME OF CONSTRUCTION. UNLESS OTHERWISE
INSTRUCTED BY THE ENGINEER, THE BACKSLOPE INTERCEPTOR
STRUCTURE SHALL BE SET AT A MAXIMUM DEPTH OF 2.5 FEET AND THE
MINIMUM GRADE FOR BACKSLOPE SWALES SHALL BE 0.2%.
6. NOT USED.
7. CLEAR AND REMOVE ALL SILT FROM CULVERTS, PIPES AND UNDER
BRIDGES TO THE PROPOSED DESIGN GRADES TO PROVIDE POSITIVE
FLOW.
8. LENGTHS AND DIAMETERS REPRESENTED ON PLANS ARE
APPROXIMATE. CONTRACTOR WILL BE RESPONSIBLE FOR FIELD
VERIFICATION PRIOR TO ORDERING MATERIALS.
9. ACTIVITIES THAT DISTURB BIRD HABITAT, INCLUDING BUT NOT LIMITED
TO CLEARING, GRUBBING, AND IMPACTS TO STRUCTURES WHERE
MIGRATORY BIRDS AND BALD EAGLES MIGHT NEST, REQUIRE A NEST
HABITAT SURVEY. DO NOT PROCEED UNTIL HARRIS COUNTY FLOOD
CONTROL DISTRICT HAS CONDUCTED A NEST HABITAT SURVEY TO
VERIFY ACTIVE MIGRATORY BIRD NESTS AND BALD EAGLE NESTS ARE
NOT PRESENT. THE HARRIS COUNTY FLOOD CONTROL DISTRICT MUST
PROVIDE WRITTEN AUTHORIZATION TO PROCEED.
10. THE CONTRACT CONTAINS UNIT ITEMS FOR THE ESTABLISHMENT OF
BEST MANAGEMENT PRACTICES FOR STORM WATER QUALITY
PURPOSES. WHEN NOT CALLED FOR IN THE PROJECT PLANS,
COORDINATE THE NEED AND LOCATION OF THESE UNIT ITEMS WITH
THE DISTRICT REPRESENTATIVE ON SITE PRIOR TO PLACEMENT. THESE
UNIT ITEMS INCLUDE, BUT ARE NOT LIMITED TO, REINFORCED SILT
FENCE FOR MATERIAL STOCKPILES, ANCHORED SODDING FOR
DISTURBED EARTHEN AREAS OR AROUND CONCRETE AND CONCRETE
INTERCEPTOR, AND STABILIZED CONSTRUCTION ACCESS FOR PROJECT
SITE INGRESS/EGRESS.
11. WHEN INCLUDED IN THE SCOPE OF WORK, THE PURPOSE OF DEEP
PLOWING THE SLOPE OR BERM OF A CHANNEL IS TO BREAK UP THE
DESICCATED SOILS AND TO ELIMINATE ANY VOIDS, OR RILLING CLOSE
TO THE SURFACE OF THE SLOPE OR BERM. THE CONTRACTOR WILL
DEEP PLOW THE SLOPE OR BERM TO A MINIMUM DEPTH OF 2 FEET IN
AREAS CONTAINING VOIDS AND/OR RILLING. IN AREAS OF VOIDS ONLY,
THE SURFACE FROM WHICH THE 2 FEET DEPTH IS MEASURED WILL BE
THE LEVEL OF THE SURROUNDING UNDISTURBED SOIL. IN AREAS OF
RILLING, THE RILLS WILL FIRST BE KNOCKED DOWN AND LEVELED OFF.
THE 2 FEET DEPTH WILL THEN BE MEASURED FROM THIS NEW
SURFACE. THE CONTRACTOR WILL DETERMINE THE MEANS AND
METHODS FOR DEEP PLOWING.)
12. TREES AND PLANTS LOCATED WITHIN A DESIGNATED TREE
PROTECTION ZONE (TPZ) SHALL BE PRESERVED. REFER TO
SPECIFICATION SECTION 01566 - TREE AND PLANT PROTECTION, FOR
DETAILED INFORMATION ON TREE AND PLANT PRESERVATION
PRACTICES AND PROCEDURES INCLUDING, BUT NOT LIMITED TO, ROOT
PRUNING, VEGETATION TRIMMING, FENCING AND OTHER
PRESERVATION OPERATIONS.
FLOOPLAIN NOTES:
1. THIS PROJECT IS LOCATED WITHIN TH E LIMITS CONTROLLED BY THE
NATIONAL FLOOD INSURANCE PROGRAM AS SHOWN ON FLOOD
INSURANCE RAT MAP (FIRM). THE EFFECTIVE FIRM MAPS FOR THE
PROJECT ARE: FIRM MAP NO. 48201C0940M, MAP REVISED 01/06/2017
2. THE PROJECT ALIGNMENT RUNS WITHIN 100-YR AE ZONE, FLOODWAY,
500 YEAR ZONE X, ETC.
3. NO FILL IS PROPOSED TO BE PLACED BELOW THE BASE FLOOD
ELEVATION WITHIN THE FLOODPLAIN.
4. CONTRACTOR SHALL CONTACT THE FLOODPLAIN MANAGEMENT OFFICE
48-HOURS PRIOR TO ANY WORK WITHIN THE FLOODPLAIN
5. ALL SPOIL MATERIAL TO BE STOCKPILED OUTSIDE OF THE 100-YEAR
FLOODPLAIN BOUNDARY. STOCKPILE LOCATION IS TO BE
COORDINATED WITH PROPERTY OWNER
CITY OF LA PORTE GENERAL CONSTRUCTION NOTES:
(APPLICABLE WITHIN CITY OF LA PORTE ROW)
1. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS BEFORE
BEGINNING CONSTRUCTION.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING SECURITY TO
PROTECT HIS OWN PROPERTY, EQUIPMENT AND WORK IN PROGRESS.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANING OF STREETS
CAUSED BY ASSOCIATED CONSTRUCTION AT CLOSE OF EACH
WORKDAY.
4. PAVED SURFACES SHALL BE PROTECTED FROM DAMAGE BY TRACKED
EQUIPMENT.
5. IRON RODS DISTURBED DURING CONSTRUCTION ARE TO BE REPLACED
BY A REGISTERED PUBLIC LAND SURVEYOR FOR THE ORIGINAL
PROPERTY OWNER AT NO SEPARATE PAY.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING AN
UPDATED REDLINED “RECORD” SET OF CONSTRUCTION DRAWINGS ON
SITE FOR INSPECTION BY THE ENGINEER.
7. CONTRACTOR MUST PROVIDE FENCING AROUND OPEN EXCAVATION
AREAS DURING NON-WORKING HOURS.
8. REFER TO THE SWPPP GENERAL NOTES FOR PROPER MEASURES AND
CONTROLS.
9. CONTRACTOR SHALL OBTAIN ALL CONSTRUCTION PERMITS REQUIRED
BY THE STANDARDS BY THE GOVERNMENTAL AGENCY HAVING
JURISDICTION.
10. EXISTING PAVEMENTS, CURBS, SIDEWALKS AND DRIVEWAYS DAMAGED
OR REMOVED DURING CONSTRUCTION SHALL BE REPLACED TO
ORIGINAL OR BETTER CONDITION IN ACCORDANCE WITH CITY OF LA
PORTE AND/OR HARRIS COUNTY CRITERIA.
11. WHENEVER UNSUITABLE MATERIAL IS ENCOUNTERED AND CANNOT BE
HANDLED BY THE EXCAVATION OR EMBANKMENT REQUIREMENTS,
THEN THE UNSUITABLE MATERIAL SHALL BE EXCAVATED TO A DEPTH
DEEMED SUITABLE BY THE ENGINEER AND THE EXCAVATED MATERIAL
SHALL BE DISPOSED OF OFF THE JOB SITE. THE EXCAVATED AREA
SHALL BE FILLED WITH SELECT FILL PER HARRIS COUNTY CRITERIA.
12. SURPLUS EXCAVATED EARTHEN MATERIAL BECOMES THE PROPERTY
OF THE CONTRACTOR AND SHALL BE REMOVED AND DISPOSED OF
OFF-SITE. INCLUDE COST OF REMOVAL AND DISPOSAL IN OTHER ITEMS
OF WHICH THIS WORK IS A COMPONENT PART, NO SEPARATE PAY. THE
MATERIAL MUST BE DISPOSED OF IN A SAFE AND LEGAL MATTER.
13. ADEQUATE DRAINAGE SHALL BE MAINTAINED AT ALL TIMES DURING
CONSTRUCTION. ANY DRAINAGE DITCH OR STRUCTURE DISTRIBUTED
DURING CONSTRUCTION SHALL BE RESTORED TO THE SATISFACTION
OF THE OWNING AUTHORITY. DAMAGE TO EXISTING PAVEMENT DURING
CONSTRUCTION SHALL BE RESTORED TO THE SATISFACTION OF THE
ENGINEER OR OWNING AUTHORITY.
14. WHERE MANHOLES ARE LOCATED WITHIN PAVED AREAS, CONTRACTOR
SHALL SET RIM ELEVATIONS. OUTSIDE OF PAVED AREAS, SET
MANHOLES 3 INCHES (MINIMUM) TO 6 INCHES (MAXIMUM) ABOVE
FINISHED GRADE. ADD SLOPE ALL AROUND MANHOLES, SLOPED AWAY
AND DOWN FROM MANHOLE RING.
15. THE PROPOSED DEVELOPMENT HAS BEEN DESIGNED NOT TO IMPEDE,
IMPOUND, OR BLOCK THE NATURAL FLOW OF WATER ACROSS
ADJACENT AND CONTIGUOUS PROPERTIES.
16. THE MORE STRINGENT OF CITY OF LA PORTE’S AND HARRIS COUNTY
FLOOD CONTROL DISTRICT'S DETAIL SHEETS SHALL APPLY WHERE
THERE IS A CONFLICT.
17. ALL AREAS ON ADJACENT FUTURE SECTION WHERE DIRT IS TO BE
PLACED SHALL FIRST BE STRIPPED OF VEGETATION AND DISPOSED OF
AT NO SEPARATE PAY.
18. CONTRACTOR IS RESPONSIBLE FOR HAVING ALL BURIED UTILITIES
IDENTIFIED, PROTECTED, REPLACED AND/OR PROPERLY REPAIRED IF
DAMAGED. REPAIRS/REPLACEMENT SHALL BE AT THE CONTRACTOR’S
EXPENSE.
19. CONTRACTOR SHALL OBTAIN AND MAINTAIN ON SITE ALL APPLICABLE
PERMITS AND AN APPROVED COPY OF THE PLANS AND
SPECIFICATIONS. NOTIFY THE CITY PUBLIC WORKS DEPARTMENT 48
HOURS PRIOR TO COMMENCEMENT OF WORK.
20. ALL CONSTRUCTION MATERIAL TESTING SHALL BE PERFORMED BY AN
INDEPENDENT TESTING LABORATORY CERTIFIED BY THE APPROPRIATE
AGENCY FOR THE FIELD OF TESTING BEING CONDUCTED AND
SUPERVISED BY A TEXAS PROFESSIONAL ENGINEER. ALL TESTING
SHALL BE PERFORMED IN ACCORDANCE WITH GENERALLY ACCEPTED
STANDARDS, INCLUDING:
A. RULES AND REGULATIONS PUBLISHED BY THE TEXAS
COMMISSION ON ENVIRONMENTAL QUALITY (TCEQ).
B. AMERICAN SOCIETY OF TESTING MATERIALS (ASTM).
C. AMERICAN CONCRETE INSTITUTE (ACI).
D. THE ASPHALT INSTITUTE
E. TEXAS DEPARTMENT OF TRANSPORTATION STANDARD
SPECIFICATIONS
21. TESTING LABORATORIES SHALL BE HIRED BY THE PROJECT OWNER OR
PROJECT ENGINEER AND CONTRACTS SHALL AVOID CONFLICTS OF
INTEREST.
22. TESTING LABORATORIES ARE NOT AUTHORIZED TO REVOKE, MODIFY,
OR RELEASE ANY REQUIREMENT OF THE SPECIFICATIONS AND THEY
MAY NOT APPROVE OR ACCEPT ANY PORTION OF WORK ON A PROJECT.
WHEN IT APPEARS THAT THE MATERIAL FURNISHED OR WORK
PERFORMED FAILS TO MEET THE CONTRACT DOCUMENT
REQUIREMENTS, THE TESTING LABORATORY SHALL PROMPTLY INFORM
THE CITY, IN WRITING, OF SUCH DEFICIENCIES.
23. ALL RETESTS OF FAILED DENSITIES SHALL BE TAKEN WITHIN FIVE
LINEAR FEET (5’) OF THE FAILED TEST.
24. MOISTURE CONTENT ON ALL SOIL DENSITY TESTS SHALL BE WITHIN
PLUS OR MINUS TWO PERCENT (2%) TO ACHIEVE A PASSING TEST,
UNLESS APPROVAL IS GRANTED BY THE CITY ENGINEER BASED UPON
SITE-SPECIFIC TESTING.
25. ANY POLLUTION CONTROL DEVICE, SOD, OR SEEDED AREA DAMAGED,
DISTURBED, OR REMOVED SHALL BE REPLACED OR REPAIRED AT THE
CONTRACTOR’S EXPENSE. THE CONTRACTOR IS RESPONSIBLE FOR
WATERING ANY SEED OR SOD WHICH HE HAS INSTALLED UNTIL 100%
OF VEGETATION IS ESTABLISHED.
Houston, Texas 77092 9900 Northwest Freeway
SHEET NUMBER
DATE: 09-Oct-2025
PR
EP
AR
ED
SCALE: AS -NOTED
OF
H C
FC
D
P R
O
JE
C T
ID
B5
-0 2-
-E
BR
O
O
KG
LE
N
S
TO
R M
W
AT
ER
D
ET
EN
TI
O
N B
AS
IN
PH
AS
E
C H
EC
KE
D
AP
PR
O
VE
D
:AB C
XO
EJ
P
AECOM Technical Services, Inc.
800 Gessner Road, Suite 1200
Houston, Texas 77024 TBPE Reg. No. F-3580
R
EV
D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
G
EN
ER
AL
N O
TE
S
O
F
L:
\L
EG
AC
Y\
US
HO
U1
FS
1\
PR
OD
\P
RO
JE
CT
S\
_P W
D\
HA
RR
IS
C
OU
NT
Y
FL
OO
D
CO
NT
RO
L
DI
ST
RI
CT
\6
2-
BR
OO
KG
LE
NA
RE
A\
0_
CA
D_
GI
S\
0_
CA
D\
-S
HE
ET
S\
SO
UT
H_
0% _S
HE
ET
S\
GE
NE
RA
L_
NO
TE
S_
AN
D_
LE
GE
ND
-6
2.
DW
G
E
D.
PA
NU
SK
A | S
AV
ED
: W ed ne sd ay , O cto be r 8 , 2
2:
:2
PM |
H
CF
CD
.C
OT
TE
D:
W ed ne sd ay
, O cto be r 8
, 2
2:
:1
PM
TO ARRANGE FOR LINES TO BE TURNED OFF OR MOVED, CALL CENTERPOINT
ENERGY AT 713-207-2222.
NOTICE: FOR YOUR SAFETY, YOU ARE REQUIRED BY TEXAS LAW TO CALL 811 AT LEAST
48 HOURS BEFORE YOU DIG SO THAT UNDERGROUND LINE CAN BE MARKED. THIS
VERIFICATION DOES NOT FULFILL YOUR OBLIGATION TO CALL 811.
VERIFICATION OF PRIVATE UTILITY LINES
DATE:
CENTERPOINT ENERGY/NATURAL GAS FACILITIES VERIFICATION ONLY. (THIS
SIGNATURE VERIFIES THAT YOU HAVE SHOWN CNP NATURAL GAS LINES
CORRECTLY -NOT TO BE USED FOR CONFLICT VERIFICATION.) (GAS SERVICE
LINES ARE NOT SHOWN.) SIGNATURE VALID FOR SIX MONTHS.
DATE:
CENTERPOINT ENERGY/UNDERGROUND ELECTRICAL FACILITIES VERIFICATION
ONLY. (THIS SIGNATURE VERIFIES EXISTING UNDERGROUND FACILITIES -NOT
TO BE USED FOR CONFLICT VERIFICATION.) SIGNATURE VALID FOR SIX
MONTHS.
DATE:
APPROVED FOR AT&T TEXAS/SWBT UNDERGROUND CONDUIT FACILITIES ONLY.
SIGNATURE VALID FOR ONE YEAR
AutoCAD SHX Text 10/09/2025
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text S
AutoCAD SHX Text
EDWARD J. PANUSKA III
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text X
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text 129856
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text E
CITY OF LA PORTE GENERAL CONSTRUCTION NOTES CONTINUED:
(APPLICABLE WITHIN CITY OF LA PORTE ROW)
26. STORM WATER POLLUTION PROTECTION SHALL BE DESIGNED,
CONSTRUCTED, MAINTAINED AND SHALL BE IN TOTAL COMPLIANCE WITH
THE STORM WATER QUALITY MANUAL OF THE CITY OF LA PORTE.
27. ANY MATERIALS OR WORKMANSHIP NOT MEETING OR EXCEEDING THE CITY
OF LA PORTE STANDARDS IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR AND SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE.
FULL REPLACEMENT REQUIRED; REPAIRS SHALL REQUIRE PRIOR
APPROVAL OF CITY ENGINEER.
28. CONTRACTOR SHALL KEEP STREETS, RIGHT-OF-WAY, AND WORK AREA
CLEAN OF DIRT, MUD, AND DEBRIS AS NEEDED.
29. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN ALL REQUIRED TRAFFIC
SAFETY CONTROL DEVICES UP TO AND INCLUDING FLAG MEN OR POLICE
OFFICERS.
30. CONTRACTOR SHALL CONTACT THE CITY OF LA PORTE TO OPERATE
EXISTING UTILITIES AND PRIOR TO MAKING TIE-INS. CONTRACTOR SHALL
NOT, AT ANY TIME, OPERATE PUBLIC UTILITIES.
31. ALL BACKFILL WITHIN PUBLIC RIGHTS-OF-WAY OR EASEMENTS SHALL BE
ENGINEERED TO 95% STANDARD PROCTOR DENSITY (IN 8 INCH LIFTS) AND
TESTED FOR ± 2% OPTIMUM BY AN APPROVED LAB.
32. THE CONTRACTOR SHALL NEVER UNLOAD ANY TRACK-TYPE VEHICLE OR
EQUIPMENT ON ANY EXISTING PAVEMENT OR CROSS OVER ANY EXISTING
PAVEMENT OR CURB.
33. ALL FINISH GRADES ARE TO CONFORM TO A MINIMUM SLOPE OF 6” PER 100
FEET. POSITIVE DRAINAGE IS DEPICTED BY ARROWS.
34. CONTRACTOR SHALL UNCOVER EXISTING UTILITIES AT ALL “POINTS OF
CROSSING” TO DETERMINE IF CONFLICTS EXIST BEFORE COMMENCEMENT
OF ANY CONSTRUCTION. NOTIFY THE ENGINEER AT ONCE OF ANY
CONFLICT.
35. CONTRACTOR SHALL PROVIDE SHEETING, SHORING, AND BRACING AS
NECESSARY TO PROTECT WORKMEN AND EXISTING UTILITIES DURING ALL
PHASES OF CONSTRUCTION AS PER O.S.H.A. REQUIREMENTS.
36. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFEGUARDING AND
PROTECTING ALL MATERIALS AND EQUIPMENT STORED ON THE JOBSITE IN
A SAFE AND WORKMAN-LIKE MANNER (DURING AND AFTER WORKING
HOURS), UNTIL JOB COMPLETION.
37. THE LOADING AND UNLOADING OF ALL PIPE, VALVE, HYDRANTS, MANHOLES
AND OTHER ACCESSORIES SHALL BE IN ACCORDANCE WITH THE
MANUFACTURER’S RECOMMENDED PRACTICES AND SHALL BE PERFORMED
WITH CARE TO AVOID ANY DAMAGE TO THE MATERIAL. THE CONTRACTOR
SHALL LOCATE AND PROVIDE THE NECESSARY STORAGE AREAS FOR
MATERIAL AND EQUIPMENT.
38. PLANS DO NOT EXTEND TO OR INCLUDE DESIGNS OR SYSTEMS
PERTAINING TO THE SAFETY OF THE CONTRACTOR OR ITS EMPLOYEES,
AGENTS, OR REPRESENTATIVES IN THE PERFORMANCE OF THE WORK. THE
SEAL OF THE REGISTERED PROFESSIONAL ENGINEER(S) IS INCORPORATED
IN THE PLANS. THE CONTRACTOR SHALL PREPARE OR OBTAIN THE
APPROPRIATE SAFETY SYSTEMS, INCLUDING CURRENT O.S.H.A.
STANDARDS FOR TRENCH SAFETY SYSTEMS, SEALED BY A LICENSED
PROFESSIONAL ENGINEER. APPROPRIATE TRENCH SAFETY PLANS SHALL
BE SUBMITTED BY THE CONTRACTOR PRIOR TO THE EXECUTION OF A
CONTRACT FOR HIS WORK. THE TRENCH SAFETY SYSTEM SHALL CONFORM
TO THE CITY OF LA PORTE TRENCH ORDINANCE.
39. ALL CHANGES IN DIRECTION FOR SIDEWALK SHALL BE DONE IN A
CURVILINEAR FASHION, NOT ANGULAR.
40. PROVIDE ONE LANE OPEN TO TRAFFIC AT ALL TIMES.
41. THE CONTRACTOR SHALL NOTIFY ALL PROPERTY OWNERS A MINIMUM OF
48 HOURS PRIOR TO STARTING CONSTRUCTION ON ALL DRIVEWAYS.
INGRESS AND EGRESS SHALL BE PROVIDED AT ALL DRIVEWAYS.
42. OPEN TRENCHES SHALL BE ALLOWED ONLY DURING ACTIVE
CONSTRUCTION AND SHALL NOT BE LEFT OPEN OVER NIGHT AND SHALL BE
FENCED OFF/BARRICADED AT END OF SHIFT. NO MORE THAN 100 FEET OF
TRENCH SHALL BE OPEN AT ALL TIME.
43. ALL SUBGRADE SHALL BE PREPARED IN CONFORMANCE WITH
GEOTECHNICAL ENGINEERING REPORT PROVIDED BY DESIGN ENGINEER.
44. CONTACT THE CITY'S PUBLIC IMPROVEMENTS INSPECTOR WITH THE CITY
OF LA PORTE PUBLIC WORKS DEPARTMENT AT 281-471-9650 PRIOR TO
STARTING WORK.
45. ALL TESTING OF UTILITY SYSTEMS SHALL BE WITNESSED BY CITY OF LA
PORTE STAFF. CONTRACTOR TO COORDINATE WITNESS TESTING WITH
CITY OF LA PORTE PROJECT MANAGER.
CITY OF LA PORTE SANITARY SEWER NOTES:
1. ONE FULL SECTION OF WATER LINE CENTERED OVER OR UNDER SANITARY
SEWER CROSSINGS; 2-FOOT MINIMUM CLEARANCE.
2. MINIMUM ONE FULL SECTION OF SANITARY SEWER, 150 PSI LINED PVC PIPE
CENTERED AT THE WATER LINE.
A. CENTER A MINIMUM ONE FULL SECTION OF SANITARY SEWER, 150 PSI
LINED PVC PIPE CENTERED AT WATER LINE, AND PROVIDE RESTRAINED
JOINTS FOR BOTH WATER AND SEWER LINES AT EACH END OF NEW PIPE
SECTION.
B. PROVIDE RESTRAINED JOINTS FOR BOTH WATER AND SANITARY SEWER
LINES AT EACH END OF THE NEW PIPE SECTION.
C. USE CEMENT-STABILIZED SAND BACKFILL FOR ALL PORTIONS OF THE
SEWER WITHIN 9 FEET OF THE WATER LINE, AS MEASURED
PERPENDICULARLY FROM ANY POINT ON THE WATER LINE TO THE
SANITARY SEWER (MINIMUM 2.5 SACKS CEMENT PER CUBIC YARD OF
SAND). THE CEMENT-STABILIZED SAND BEDDING SHALL START AT A
POINT 6 INCHES BELOW THE BOTTOM OF SANITARY SEWER TO 6 INCHES
ABOVE THE TOP OF THE SANITARY SEWER AND ONE QUARTER OF THE
PIPE DIAMETER OR 6 INCHES, WHICHEVER IS GREATER, ON THE SIDE OF
THE SEWER.
3. SANITARY SEWERS SHALL BE CONSTRUCTED, BEDDED, BACKFILLED AND
TESTED IN ACCORDANCE WITH CITY OF LA PORTE STANDARD
SPECIFICATION AND STANDARD CONSTRUCTION DETAILS.
4. ALL MANHOLE RIMS SHALL BE SET 3" (MINIMUM) TO 6" (MAXIMUM) ABOVE
NATURAL GROUND LEVEL AND GROUND SHALL BE SLOPED TO DRAIN AWAY
FROM MANHOLE.
5. ALL SANITARY SEWER MANHOLES TO BE 4' DIAMETER UNLESS OTHERWISE
NOTED.
6. CONTRACTOR TO PROVIDE NECESSARY SHEET PILING DURING MANHOLE
CONSTRUCTION TO INSURE NO DAMAGE TO EXISTING PAVEMENT AND/OR
CURBING. NO SEPARATE PAY.
7. NO CONNECTIONS SHALL BE MADE TO EXISTING SANITARY SEWER LINES
UNTIL ALL PROPOSED SEWER LINES HAVE BEEN THOROUGHLY CLEANED,
TESTED AND APPROVED BY THE ENGINEER. NOTIFY ENGINEER AT LEAST 48
HOURS PRIOR TO CONNECTION TO ANY EXISTING SEWER LINES.
8. WATERLINE/MANHOLE SEPARATION: SANITARY SEWER MANHOLES MUST
BE INSTALLED SO AS TO PROVIDE NINE FEET OF HORIZONTAL CLEARANCE
FROM AN EXISTING OR PROPOSED WATERLINE.
9. SANITARY SEWER MANHOLES: BRICK MANHOLES WILL NOT BE ALLOWED.
ALL MANHOLES WILL BE PRECAST CONCRETE CONFORMING TO CITY OF LA
PORTE SPECIFICATIONS.
10. CONTRACTOR SHALL KEEP RECORD OF LOCATION OF ALL STACKS, STUBS,
ETC.
11. THIS ORGANIZED SEWAGE COLLECTION SYSTEM MUST BE DESIGNED AND
CONSTRUCTED IN ACCORDANCE WITH THE TEXAS COMMISSION ON
ENVIRONMENTAL QUALITY'S RULES 30 TEXAS ADMINISTRATIVE CODE (TAC)
§217.51-217.70, AND THE CITY OF LA PORTE STANDARD SPECIFICATIONS
12. SEWER LINES MUST BE TESTED FROM MANHOLE TO MANHOLE. WHEN A
NEW SEWER LINE IS CONNECTED TO AN EXISTING STUB OR CLEAN-OUT, IT
MUST BE TESTED FROM EXISTING MANHOLE TO NEW MANHOLE. IF A STUB
OR CLEAN-OUT IS USED AT THE END OF THE PROPOSED SEWER LINE, NO
PRIVATE SERVICE ATTACHMENTS MAY BE CONSTRUCTED BETWEEN THE
LAST MANHOLE AND THE CLEAN OUT UNLESS IT CAN BE CERTIFIED AS
CONFORMING WITH THE PROVISIONS OF 30 TAC §217.57.
13. ALL SEWER LINES MUST BE TESTED IN ACCORDANCE WITH 30 TAC §217.57.
THE CONTRACTOR MUST RETAIN COPIES OF ALL TEST RESULTS WHICH
MUST BE MADE AVAILABLE TO THE EXECUTIVE DIRECTOR UPON REQUEST.
THE CONTRACTOR MUST CERTIFY IN WRITING THAT ALL WASTEWATER
LINES HAVE PASSED ALL REQUIRED TESTING TO THE APPROPRIATE
REGIONAL OFFICE WITHIN 30 DAYS OF TEST COMPLETION AND PRIOR TO
USE OF THE NEW COLLECTION SYSTEM. TESTING METHOD SHALL BE
INFILTRATION OR EXFILTRATION TEST, LOW PRESSURE AIR TEST, AND
DEFLECTION TESTING.
14. DEFLECTION TESTING SHALL BE PERFORMED ON ALL FLEXIBLE PIPES. FOR
PIPELINES WITH INSIDE DIAMETERS LESS THAN 27 INCHES, A RIGID
MANDREL MUST BE USED TO MEASURE DEFLECTION. THE TEST MUST BE
CONDUCTED AFTER THE FINAL BACKFILL HAS BEEN IN PLACE AT LEAST 30
DAYS, AND NO PIPE WILL EXCEED A DEFLECTION OF FIVE PERCENT. IF THE
PIPE SHOULD FAIL TO PASS THE DEFLECTION TEST, THE PROBLEM MUST
BE CORRECTED AND A SECOND TEST MUST BE CONDUCTED AFTER FINAL
BACKFILL HAS BEEN IN PLACE AN ADDITIONAL 30 DAYS.
15. ALL MANHOLES MUST BE TESTED TO MEET OR EXCEED THE
REQUIREMENTS OF 30 TAC §217.58.
16. STACKS SHALL BE BUILT IN ACCORDANCE WITH THE CITY OF LA PORTE
STANDARD DETAIL DRAWING REQUIREMENTS. EXACT LOCATION OF THE
STACK SHALL BE SUPPLIED TO THE CITY ENGINEER OF LA PORTE BY THE
PROJECT ENGINEER ON SEALED AS-BUILT DRAWINGS AT COMPLETION OF
CONSTRUCTION. ALL STACKS SHALL BE INSTALLED WITHIN 3% OF PLUMB
RELATIVE TO VERTICAL PLANE AND WILL BE CAPPED AND TERMINATED AT
A DEPTH OF 4 FEET BELOW FINISHED GRADE, UNLESS OTHERWISE
DIRECTED BY THE CITY OF LA PORTE ENGINEER.
17. EACH SANITARY SEWER SERVICE LEAD STUB, PLUGGED WYE BRANCH
OUTLET AND STACK SHALL BE 4" PVC PIPE AT THE TIME OF
CONSTRUCTION, BEGINNING AT THE INVERT ELEVATION OF THE STUB OR
WYE AND AT AN ELEVATION TWO FEET BELOW THE CAPPED TERMINATION
POINT OF THE STACK AND EXTENDING TWO FEET ABOVE FINISHED GRADE.
EACH MARKER SHALL BE PAINTED RED AND LABELED "SANITARY SEWER
STUB", "SANITARY SEWER WYE" OR "SANITARY SEWER STACK" AS
APPROPRIATE WITH STUB, WYE BRANCH OUTLET OR STACK SIZE NOTED.
18. SANITARY SEWER MANHOLE COVERS SHALL BE MINIMUM OF 32 INCHES IN
DIAMETER. ALL SUCH MANHOLE COVERS SHALL HAVE THE CITY OF LA
PORTE EMBLEM AND THE WORDS "LA PORTE" AND "SANITARY SEWER"
CAST IN RAISED RELIEF AS DEPICTED IN CITY OF LA PORTE STANDARD
CONSTRUCTION DETAILS SHEETS. ALL MANHOLE COVERS SHALL BE MADE
IMPERMEABLE TO SURFACE DRAINAGE BY PROVIDING A SOLID COVER.
INFLOW PROTECTORS ARE INCIDENTAL TO THE MANHOLE AND COST SHALL
BE INCORPORATED ACCORDINGLY.
19. ALL NEW MANHOLES SHALL HAVE AN INTERIOR SURFACE COATED WITH
XYPEX ADMIX C-1000. EPOXY COATING OF A MINIMUM 100 MILS THICK MAY
BE USED AS AN ALTERNATIVE TO XYPEX ADMIX C-1000 WITH APPROVAL
FROM CITY OF LA PORTE ENGINEER. BITUMINOUS COATINGS ARE NOT
ALLOWED. COATINGS SHALL BE TESTED WITH A HOLIDAY TESTER. TESTING
SHALL BE IN ACCORDANCE WITH LATEST EDITION OF NACE "STANDARD
RECOMMENDED PRACTICE DISCONTINUITY TESTING OF PROTECTIVE
COATINGS" ALL HOLIDAY TESTERS SHALL BE MARKED AND REPAIRED AND
RETESTED. ALL JOINTS SHALL BE GROUTED SMOOTH PRIOR TO
INSTALLATION OF THE INTERIOR COATING. SHOULD THE MANHOLE BE
PRE-COATED AT THE PLACE OF MANUFACTURING THE JOINT SHALL BE
GROUTED SMOOTH AND THE GROUTED AREA SHALL BE COATED IN
ACCORDANCE WITH THIS SECTION.
20. ALL EXISTING UNDERGROUND UTILITIES ARE NOT GUARANTEED TO BE
COMPLETE OR DEFINITE. THE APPROXIMATE LOCATIONS OF KNOWN
EXISTING UTILITIES ARE SHOWN. CONTRACTOR SHALL DETERMINE THE
EXACT SIZE AND HORIZONTAL AND VERTICAL LOCATIONS IN THE FIELD.
THE CONTRACTOR SHALL NOTIFY ALL OF THE PROPER GOVERNING
AUTHORITIES (STATE, COUNTY, OR CITY) AT LEAST 48 HOURS PRIOR TO
COMMENCING WORK.
21. ANY PERMANENT RELOCATION OF AN EXISTING UTILITY NOT SHOWN ON
THE DRAWINGS SHALL BE APPROVED BY THE CITY OF LA PORTE ENGINEER
PRIOR TO RELOCATION AND SHALL CONFORM TO THE APPLICABLE
STANDARD OF GOVERNING AUTHORITIES.
22. CONTRACTOR SHALL PROTECT EXISTING UNDERGROUND FACILITIES
DURING INSTALLATION OF PROPOSED WORK.
23. IN THE EVENT THAT ANY CONTAMINATED MATERIALS OR SUSPECT
CONTAMINATED MATERIALS ARE ENCOUNTERED DURING CONSTRUCTION
ACTIVITIES, THE CONTRACTOR SHALL CEASE OPERATIONS IN THAT AREA
AND IMMEDIATELY NOTIFY THE ENGINEER.
24. ALL GRAVITY SANITARY SEWERS SHALL BE CONSTRUCTED OF PVC PIPE
(ASTM D-3034, SDR 26 OR THICKER), AS NOTED ON THE DRAWINGS.
25. ALL FORCE MAIN SANITARY SEWERS SHALL BE CONSTRUCTED OF C-900
PVC PIPE, UNLESS OTHERWISE NOTED.
Houston, Texas 77092 9900 Northwest Freeway
SHEET NUMBER
DATE: 09-Oct-2025
PR
EP
AR
ED
SCALE: AS -NOTED
OF
H C
FC
D
P R
O
JE
C T
ID
B5
-0 2-
-E
BR
O
O
KG
LE
N
S
TO
R M
W
AT
ER
D
ET
EN
TI
O
N B
AS
IN
PH
AS
E
C H
EC
KE
D
AP
PR
O
VE
D
:AB C
XO
EJ
P
AECOM Technical Services, Inc.
800 Gessner Road, Suite 1200
Houston, Texas 77024 TBPE Reg. No. F-3580
R
EV
D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
G
EN
ER
AL
N O
TE
S
O
F
L:
\L
EG
AC
Y\
US
HO
U1
FS
1\
PR
OD
\P
RO
JE
CT
S\
_P W
D\
HA
RR
IS
C
OU
NT
Y
FL
OO
D
CO
NT
RO
L
DI
ST
RI
CT
\6
2-
BR
OO
KG
LE
NA
RE
A\
0_
CA
D_
GI
S\
0_
CA
D\
-S
HE
ET
S\
SO
UT
H_
0% _S
HE
ET
S\
GE
NE
RA
L_
NO
TE
S_
AN
D_
LE
GE
ND
-6
2.
DW
G
E
D.
PA
NU
SK
A | S
AV
ED
: W ed ne sd ay , O cto be r 8 , 2
2:
:2
PM |
H
CF
CD
.C
OT
TE
D:
W ed ne sd ay
, O cto be r 8
, 2
2:
:1
PM
TO ARRANGE FOR LINES TO BE TURNED OFF OR MOVED, CALL CENTERPOINT
ENERGY AT 713-207-2222.
NOTICE: FOR YOUR SAFETY, YOU ARE REQUIRED BY TEXAS LAW TO CALL 811 AT LEAST
48 HOURS BEFORE YOU DIG SO THAT UNDERGROUND LINE CAN BE MARKED. THIS
VERIFICATION DOES NOT FULFILL YOUR OBLIGATION TO CALL 811.
VERIFICATION OF PRIVATE UTILITY LINES
DATE:
CENTERPOINT ENERGY/NATURAL GAS FACILITIES VERIFICATION ONLY. (THIS
SIGNATURE VERIFIES THAT YOU HAVE SHOWN CNP NATURAL GAS LINES
CORRECTLY -NOT TO BE USED FOR CONFLICT VERIFICATION.) (GAS SERVICE
LINES ARE NOT SHOWN.) SIGNATURE VALID FOR SIX MONTHS.
DATE:
CENTERPOINT ENERGY/UNDERGROUND ELECTRICAL FACILITIES VERIFICATION
ONLY. (THIS SIGNATURE VERIFIES EXISTING UNDERGROUND FACILITIES -NOT
TO BE USED FOR CONFLICT VERIFICATION.) SIGNATURE VALID FOR SIX
MONTHS.
DATE:
APPROVED FOR AT&T TEXAS/SWBT UNDERGROUND CONDUIT FACILITIES ONLY.
SIGNATURE VALID FOR ONE YEAR
AutoCAD SHX Text 10/09/2025
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text S
AutoCAD SHX Text
EDWARD J. PANUSKA III
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text X
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text 129856
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text E
CITY OF LA PORTE SANITARY SEWER NOTES CONTINUED:
26. ALL SEWERS UNDER OR WITHIN TWO (2) FEET OF PROPOSED OR FUTURE
PAVEMENT SHALL BE BACKFILLED WITH 2 SACK CEMENT STABILIZED SAND
PER C.Y. TO BOTTOM OF PROPOSED PAVEMENT.
27. COST OF SPECIAL BACKFILL AND BEDDING IS INCIDENTAL TO THE UNIT
PRICE BID PER LINEAR FOOT.
28. ALL SANITARY SEWERS SHALL BE CONSTRUCTED IN ACCORDANCE WITH
THE TEXAS COMMISSION ON ENVIRONMENTAL QUALITY, CHAPTER 217.51
-217.70, SEWAGE COLLECTION SYSTEMS.
29. CONTRACTOR SHALL OBTAIN ALL CONSTRUCTION PERMITS REQUIRED BY
THE STANDARDS OF THE GOVERNMENTAL AGENCY HAVING JURISDICTION.
30. SANITARY MANHOLES WITHIN THE FLOOD PLAIN SHALL BE RAISED ABOVE
THE 100 YEAR FLOOD ELEVATION NOT SEALED AND VENTED.
31. ALL SLEEVES TO BE FOUR (4) INCH SCHEDULE 40 PVC AND SLEEVES TO BE
EIGHTEEN (18) INCHES BELOW THE…
This is the start of the file's text. The full file is on GovTribe.