26-8629_-_Exhibit_P_Clam_Pass_Park_Hurricane_Ian_Repairs-Addendum_No._1-Sheet_S-1_SS.pdf

PDF 286 KB Posted

Attached to
Clam Pass Park - Hurricane Ian Repairs (GRANT FUNDED)
Solicitation number
26-8629
Issued by
Collier County, Florida

About this file

This is a preliminary construction drawing sheet for Collier County, Florida's Clam Pass Park Hurricane Ian Repairs project, Bid No. 26-8629, prepared by Taylor Engineering, Inc. The document provides detailed technical specifications and construction drawings for timber boardwalk repairs, specifically showing existing conditions and the structural details required for restoration of approximately 3,200 linear feet of boardwalk damaged by Hurricane Ian. The sheet illustrates timber pile foundations, decking assemblies constructed from 2"x8" IPE boards, stringer configurations, handrail systems with 4"x6" railing posts, and utility support infrastructure incorporating 316 stainless steel components. The drawing includes specifications for 10-inch diameter timber piles, 4"x14" pile caps, 5/8-inch through bolts with washers, stainless steel deck screws, and new Simpson H8SS hurricane ties for structural reinforcement. Sealed bids must be submitted electronically by May 22, 2026, at 3:00 p.m. local time, with a non-mandatory pre-bid meeting scheduled for April 21, 2026, at 12:00 p.m. Site visits are strongly recommended prior to bidding. The contractor must complete substantial work within 150 calendar days from the Notice to Proceed, with liquidated damages of $2,702 per calendar day assessed for failure to meet the deadline.

The project is entirely grant-funded through FEMA Public Assistance grants, with an anticipated project budget of $2,500,000 for the Base Bid, plus owner's allowances totaling $226,400 for unforeseen conditions. Bid Alternate No. 1 and No. 2 are available for additional selective structural repairs and full lumber replacement, respectively, each with associated costs and increased liquidated damages of $4,285 per day if Alternate No. 2 is selected. The project is subject to Collier County's local vendor preference policy and requires compliance with federal regulations including 2 CFR Part 200, prevailing wage requirements, the Robert T. Stafford Disaster Relief and Emergency Assistance Act, Contract Work Hours and Safety Standards Act provisions, Build America Buy America Act guidance, and Florida Statute Section 255.20 regarding procurement of Florida-produced lumber. Bidders must submit a certified Bid Bond equal to five percent of the total bid amount and execute Payment and Performance Bonds at 100 percent of the contract amount. All bidders must be enrolled in E-Verify, maintain valid Florida business tax receipts and professional licenses, and comply with Collier County's Environmental, Health and Safety Contractor Requirements and Vertical Construction Standards.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

8'-0"

4"Ø HDPE SEWER

LINE (V.I.F.) 3"Ø CPVC

ELECTRICAL

CONDUIT (V.I.F.)

3"Ø HDPE WATER

LINE (V.I.F.)

SEE SHEET PE-1 FOR UTILITY SUPPORT

REPAIR AND/OR REPLACEMENT

2"x8"x11' IPE DECKING 2"x8" RAIL

2"x8" IPE CAP

10" DIA. TIMBER PILE

UTILITY SUPPORT

EXISTING GRADE

4" x14"x12'

PILE CAPS

3/4"Ø THROUGH BOLTS W/

WASHERS BOTH ENDS

4" x14"x22'

STRINGERS

6"x6"x10'

WHEEL

GUARD

4"x6" (10' O.C.)

RAILING POST

2"x8" IPE CAP

4"x6" SPACER

4"x14"x22'

STRINGERS

5/8"Ø THROUGH BOLTS W/

WASHERS BOTH ENDS

2"x8"x11' IPE DECKING

(3) STAINLESS

STEEL SCREWS

(3) STAINLESS

STEEL SCREWS

4"x6" (10' O.C.)

RAILING POST

20'-0"

3/4"Ø THROUGH BOLTS

W/ WASHERS BOTH ENDS

4"x6" (10' O.C.)

RAILING POST

4"x6" SPACER ( SEE

HANDRAIL SPACER DETAIL)

5/8"Ø THROUGH BOLTS

W/ WASHERS BOTH

ENDSSTRINGER VI

STRINGER V

STRINGER IV

STRINGER III

STRINGER II

STRINGER I

2"x8" RAIL

5/8"Ø THROUGH BOLTS W/

WASHERS BOTH ENDS

STAINLESS STEEL

UTILITY STRAPUTILITY SUPPORT

10" DIA. TIMBER PILE

EXISTING GRADE

A

S-3

PILE B

PILE A

4"x4" STRINGER TIE (EACH

STRINGER) W/ 5/8"Ø BOLTS

NEW SIMPSON H8SS

HURRICANE TIE EACH DECK

JOIST, (12) TOTAL EACH BENT

SEE SHEET PE-1 FOR UTILITY

SUPPORT REPAIR AND/OR

REPLACEMENT

4"x14" BLOCKING (TYP)

+8.91 FT NAVD TYP

(VARIES FROM +5.5 TO

+11.92 FT NAVD)

MHW = -0.06' NAVD MHW = -0.06' NAVD

FOR MUCH OF THE SITE, THE HIGH WATER LINE

IS ABOVE THE MUDLINE. THE CONTRACTOR

SHALL ACCOUNT FOR PERFORMING WORK IN

THE WET. VARIATIONS IN WATER LEVELS WILL

NOT SERVE AS A BASIS FOR SCHEDULE

EXTENSIONS OR ADDITIONAL COMPENSATION.

FOR MUCH OF THE SITE, THE HIGH WATER LINE

IS ABOVE THE MUDLINE. THE CONTRACTOR

SHALL ACCOUNT FOR PERFORMING WORK IN

THE WET. VARIATIONS IN WATER LEVELS WILL

NOT SERVE AS A BASIS FOR SCHEDULE

EXTENSIONS OR ADDITIONAL COMPENSATION.

NOTCH IN PILE FOR

CAP BEARING (TYP)

2"x4"x2' SUPPORT BLOCK (10'

O.C. BETWEEN RAILING POSTS).

FASTEN WITH (2) STAINLESS

STEEL DECK SCREWS EACH

BLOCK, 1" MIN EMBED.

B

S-3

2"x4"x2' SUPPORT BLOCK (10' O.C. BETWEEN

RAILING POSTS). FASTEN WITH (2) STAINLESS

STEEL DECK SCREWS EACH BLOCK, 1" MIN EMBED.

DESIGNED

DRAWN

CHECKED

REVIEWED

DATE

SHEET TITLE

SHEET OF

21 3 4 5 6 7 8

A

B

C

D

E

F

G

H

TIMBER

BOARDWALK

DETAILS (EXISTING

CONDITIONS)

S-1

PE

TE

R J

AN

SE

N , 5

/5 /2

9:

:2

AM

, X

:\s ys

\P ro je ct s\ c2

3-

4_

C ol lie rC la m

Pa ss

\P er m it\

Ti m be r B oa rd w al k\ c2

3-

4-

P- Ti m be rB oa rd w al kD et ai ls .d w g

EAW

PNJ

EAW

JHS

MAR 2026

PR

EL

IM

IN

AR

Y

D R

AW

IN

G S:

T H

ES

E

D R

AW

IN

G S

AR

E

N O

T C

O N

ST

R

U C

TI

O

N

N O

R

EV

IS

IO

N S

/ S U

BM

IS

SI

O

N S

D

AT

E

ZO

N E

AD

D

EN

D

U M

N O

. 1 5/

5/

PROJECT NO C2023-054

10199 SOUTHSIDE BLVD

SUITE 310

JACKSONVILLE, FLORIDA 32256

(904)-731-7040

REGISTRY # 4815

C

LA

M P

AS

S

PA

R

K H

U R

R

IC

AN

E

IA

N

R

EP

AI

R

S C

O

LL

IE

R

C O

U N

TY

, F

LO

R

ID

A

SEAL

TAYLOR

ENGINEERING, INC.

VIEWNUMBER

SCALE: 1" = 2'

HANDRAIL SPACER DETAILB

2'

VIEWNUMBER

SCALE: 1" = 2'

SECTION A-AA

2' 0

VIEWNUMBER

SCALE: 1" = 2'

SIDE VIEW2

2'

GENERAL NOTES

1. ALL DETAILS, DIMENSIONS, AND MATERIAL SPECIFICATIONS SHOWN HERE-ON

REFERENCE THE CLAM PASS PARK ORIGINAL 1986 BOARDWALK DRAWINGS

AND THE 2019 CLAM PASS PARK REPAIR PLANS. EXISTING CONDITIONS MAY

VARY FROM WHAT IS SHOWN HEREON, THE CONTRACTOR SHALL FIELD

VERIFY ALL MEMBER SIZES, SPACING, AND DIMENSIONS PRIOR TO

REPLACEMENT. IF THE CONTRACTOR IDENTIFIES DISCREPANCIES OR

ADDITIONAL AREAS NOT INCLUDED HEREON, THE CONTRACTOR SHALL

IMMEDIATELY NOTIFY THE OWNER AND ENGINEER FOR REVIEW.

2. SEE SHEET G-2 FOR TECHNICAL SPECIFICATIONS.

3. PRIOR TO FURNISHING MATERIALS, THE CONTRACTOR SHALL SUBMIT

MANUFACTURER’S INFORMATION FOR ALL LUMBER AND HARDWARE TO

DEMONSTRATE COMPLIANCE WITH THE SPECIFIED SIZE, TYPE, SPECIES,

GRADE, AND MATERIAL REQUIREMENTS.

VIEWNUMBER

SCALE: 1" = 2'

TOP VIEW1

2'

2026-05-05T09:34:38-0400
Jake Sydnor

File details come from the government source that posted it. Updated .