This is a preliminary construction drawing sheet for Collier County, Florida's Clam Pass Park Hurricane Ian Repairs project, Bid No. 26-8629, prepared by Taylor Engineering, Inc. The document provides detailed technical specifications and construction drawings for timber boardwalk repairs, specifically showing existing conditions and the structural details required for restoration of approximately 3,200 linear feet of boardwalk damaged by Hurricane Ian. The sheet illustrates timber pile foundations, decking assemblies constructed from 2"x8" IPE boards, stringer configurations, handrail systems with 4"x6" railing posts, and utility support infrastructure incorporating 316 stainless steel components. The drawing includes specifications for 10-inch diameter timber piles, 4"x14" pile caps, 5/8-inch through bolts with washers, stainless steel deck screws, and new Simpson H8SS hurricane ties for structural reinforcement. Sealed bids must be submitted electronically by May 22, 2026, at 3:00 p.m. local time, with a non-mandatory pre-bid meeting scheduled for April 21, 2026, at 12:00 p.m. Site visits are strongly recommended prior to bidding. The contractor must complete substantial work within 150 calendar days from the Notice to Proceed, with liquidated damages of $2,702 per calendar day assessed for failure to meet the deadline.
The project is entirely grant-funded through FEMA Public Assistance grants, with an anticipated project budget of $2,500,000 for the Base Bid, plus owner's allowances totaling $226,400 for unforeseen conditions. Bid Alternate No. 1 and No. 2 are available for additional selective structural repairs and full lumber replacement, respectively, each with associated costs and increased liquidated damages of $4,285 per day if Alternate No. 2 is selected. The project is subject to Collier County's local vendor preference policy and requires compliance with federal regulations including 2 CFR Part 200, prevailing wage requirements, the Robert T. Stafford Disaster Relief and Emergency Assistance Act, Contract Work Hours and Safety Standards Act provisions, Build America Buy America Act guidance, and Florida Statute Section 255.20 regarding procurement of Florida-produced lumber. Bidders must submit a certified Bid Bond equal to five percent of the total bid amount and execute Payment and Performance Bonds at 100 percent of the contract amount. All bidders must be enrolled in E-Verify, maintain valid Florida business tax receipts and professional licenses, and comply with Collier County's Environmental, Health and Safety Contractor Requirements and Vertical Construction Standards.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
8'-0"
4"Ø HDPE SEWER
LINE (V.I.F.) 3"Ø CPVC
ELECTRICAL
CONDUIT (V.I.F.)
3"Ø HDPE WATER
LINE (V.I.F.)
SEE SHEET PE-1 FOR UTILITY SUPPORT
REPAIR AND/OR REPLACEMENT
2"x8"x11' IPE DECKING 2"x8" RAIL
2"x8" IPE CAP
10" DIA. TIMBER PILE
UTILITY SUPPORT
EXISTING GRADE
4" x14"x12'
PILE CAPS
3/4"Ø THROUGH BOLTS W/
WASHERS BOTH ENDS
4" x14"x22'
STRINGERS
6"x6"x10'
WHEEL
GUARD
4"x6" (10' O.C.)
RAILING POST
2"x8" IPE CAP
4"x6" SPACER
4"x14"x22'
STRINGERS
5/8"Ø THROUGH BOLTS W/
WASHERS BOTH ENDS
2"x8"x11' IPE DECKING
(3) STAINLESS
STEEL SCREWS
(3) STAINLESS
STEEL SCREWS
4"x6" (10' O.C.)
RAILING POST
20'-0"
3/4"Ø THROUGH BOLTS
W/ WASHERS BOTH ENDS
4"x6" (10' O.C.)
RAILING POST
4"x6" SPACER ( SEE
HANDRAIL SPACER DETAIL)
5/8"Ø THROUGH BOLTS
W/ WASHERS BOTH
ENDSSTRINGER VI
STRINGER V
STRINGER IV
STRINGER III
STRINGER II
STRINGER I
2"x8" RAIL
5/8"Ø THROUGH BOLTS W/
WASHERS BOTH ENDS
STAINLESS STEEL
UTILITY STRAPUTILITY SUPPORT
10" DIA. TIMBER PILE
EXISTING GRADE
A
S-3
PILE B
PILE A
4"x4" STRINGER TIE (EACH
STRINGER) W/ 5/8"Ø BOLTS
NEW SIMPSON H8SS
HURRICANE TIE EACH DECK
JOIST, (12) TOTAL EACH BENT
SEE SHEET PE-1 FOR UTILITY
SUPPORT REPAIR AND/OR
REPLACEMENT
4"x14" BLOCKING (TYP)
+8.91 FT NAVD TYP
(VARIES FROM +5.5 TO
+11.92 FT NAVD)
MHW = -0.06' NAVD MHW = -0.06' NAVD
FOR MUCH OF THE SITE, THE HIGH WATER LINE
IS ABOVE THE MUDLINE. THE CONTRACTOR
SHALL ACCOUNT FOR PERFORMING WORK IN
THE WET. VARIATIONS IN WATER LEVELS WILL
NOT SERVE AS A BASIS FOR SCHEDULE
EXTENSIONS OR ADDITIONAL COMPENSATION.
FOR MUCH OF THE SITE, THE HIGH WATER LINE
IS ABOVE THE MUDLINE. THE CONTRACTOR
SHALL ACCOUNT FOR PERFORMING WORK IN
THE WET. VARIATIONS IN WATER LEVELS WILL
NOT SERVE AS A BASIS FOR SCHEDULE
EXTENSIONS OR ADDITIONAL COMPENSATION.
NOTCH IN PILE FOR
CAP BEARING (TYP)
2"x4"x2' SUPPORT BLOCK (10'
O.C. BETWEEN RAILING POSTS).
FASTEN WITH (2) STAINLESS
STEEL DECK SCREWS EACH
BLOCK, 1" MIN EMBED.
B
S-3
2"x4"x2' SUPPORT BLOCK (10' O.C. BETWEEN
RAILING POSTS). FASTEN WITH (2) STAINLESS
STEEL DECK SCREWS EACH BLOCK, 1" MIN EMBED.
DESIGNED
DRAWN
CHECKED
REVIEWED
DATE
SHEET TITLE
SHEET OF
21 3 4 5 6 7 8
A
B
C
D
E
F
G
H
TIMBER
BOARDWALK
DETAILS (EXISTING
CONDITIONS)
S-1
PE
TE
R J
AN
SE
N , 5
/5 /2
9:
:2
AM
, X
:\s ys
\P ro je ct s\ c2
3-
4_
C ol lie rC la m
Pa ss
\P er m it\
Ti m be r B oa rd w al k\ c2
3-
4-
P- Ti m be rB oa rd w al kD et ai ls .d w g
EAW
PNJ
EAW
JHS
MAR 2026
PR
EL
IM
IN
AR
Y
D R
AW
IN
G S:
T H
ES
E
D R
AW
IN
G S
AR
E
N O
T C
O N
ST
R
U C
TI
O
N
N O
R
EV
IS
IO
N S
/ S U
BM
IS
SI
O
N S
D
AT
E
ZO
N E
AD
D
EN
D
U M
N O
. 1 5/
5/
PROJECT NO C2023-054
10199 SOUTHSIDE BLVD
SUITE 310
JACKSONVILLE, FLORIDA 32256
(904)-731-7040
REGISTRY # 4815
C
LA
M P
AS
S
PA
R
K H
U R
R
IC
AN
E
IA
N
R
EP
AI
R
S C
O
LL
IE
R
C O
U N
TY
, F
LO
R
ID
A
SEAL
TAYLOR
ENGINEERING, INC.
VIEWNUMBER
SCALE: 1" = 2'
HANDRAIL SPACER DETAILB
2'
VIEWNUMBER
SCALE: 1" = 2'
SECTION A-AA
2' 0
VIEWNUMBER
SCALE: 1" = 2'
SIDE VIEW2
2'
GENERAL NOTES
1. ALL DETAILS, DIMENSIONS, AND MATERIAL SPECIFICATIONS SHOWN HERE-ON
REFERENCE THE CLAM PASS PARK ORIGINAL 1986 BOARDWALK DRAWINGS
AND THE 2019 CLAM PASS PARK REPAIR PLANS. EXISTING CONDITIONS MAY
VARY FROM WHAT IS SHOWN HEREON, THE CONTRACTOR SHALL FIELD
VERIFY ALL MEMBER SIZES, SPACING, AND DIMENSIONS PRIOR TO
REPLACEMENT. IF THE CONTRACTOR IDENTIFIES DISCREPANCIES OR
ADDITIONAL AREAS NOT INCLUDED HEREON, THE CONTRACTOR SHALL
IMMEDIATELY NOTIFY THE OWNER AND ENGINEER FOR REVIEW.
2. SEE SHEET G-2 FOR TECHNICAL SPECIFICATIONS.
3. PRIOR TO FURNISHING MATERIALS, THE CONTRACTOR SHALL SUBMIT
MANUFACTURER’S INFORMATION FOR ALL LUMBER AND HARDWARE TO
DEMONSTRATE COMPLIANCE WITH THE SPECIFIED SIZE, TYPE, SPECIES,
GRADE, AND MATERIAL REQUIREMENTS.