26-007378 - Sole Source Memo.docx
DOCX document 76 KB Posted
- Attached to
- Real Time Location System (RTLS)
- Solicitation number
- 26-007378
About this file
This is a Sole Source Justification and Approval memo dated June 19, 2026, from the NIH Clinical Center's Supervisor of Biomedical Engineering requesting authorization for a sole source procurement from Conexus, Inc. The acquisition is a follow-on contract to add 426 RTLS (Real Time Location System) tags to the existing Conexus contract (PO #75N90022F00105). The procurement includes 421 RTLS/Wi-Fi Asset Tags with Cradles, Plexus Licensing, and Tag Activation, with a total cost of $74,938.00. The justification cites FAR 13.106-1(b)(1) authority for purchases not exceeding the simplified acquisition threshold, asserting that only one source is reasonably available due to the specialized nature of the requirement.
The memo establishes that Conexus is the sole qualified vendor because it is the only company authorized to connect RTLS tags to the Plexus asset tracking system and is the exclusive provider of Securitas RTLS tags verified for use with this system. The system has undergone Assessment and Authorization to Operate (ATO) on DoD networks through the Defense Health Agency using NIST Risk Management Framework standards and integrates barcode, passive RFID, and active Wi-Fi technologies into a unified platform. The Clinical Center requires this specific solution for consistency in protocol-based care, patient safety, IT standardization, and cybersecurity compliance. Market research was conducted through ECRI equipment comparison reports and industry conferences, and cost reasonableness was established through comparison with past procurements and industry standards. No competing sources expressed interest in the acquisition.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Date: June 19, 2026
From: David Ram, Supervisor of Biomedical Engineering—NIH Clinical Center
Subject: SOLE SOURCE JUSTIFICATION AND APPROVAL
To: NIH, CLINICAL CENTER, CONTRACTING OFFICER
1. AGENCY IDENTIFICATION AND CONTRACTING ACTIVITY
David Ram, supervisor of Biomedical Engineering National Institute of Health Clinical Center 9000 Rockville Pike Bethesda, MD 20892 AO’s Name, contact information: Kevin Doty- 301-496-5314
Contracting Activity:
NIH Clinical Center Office of Purchasing and Contracts 6707 Democracy Blvd Bethesda, MD 20892
2. NATURE AND/OR DESCRIPTION OF THE ACQUISITION BEING APPROVED
This is a follow-on contract to add 426 RTLS tags to the NIH awarded Conexus contract, PO #: 75N90022F00105. (NIH/CC is seeking a system consisting of Real Time Location System (RTLS) with 802.11(WI-FI) and Stationary RFID Fixed Readers to create a record as RFID-tagged items are “seen” when they pass under the Reader antenna. The CC is looking to monitor "real time" locations of about 2,000 portable medical devices and about 30,000 devices on a fix reader system). DESCRIPTION OF THE SUPPLIES AND SERVICES REQUIRED, INCLUDING THE DELIVERY SCHEDULE AND/OR THE PERIOD OF PERFORMANCE and DOLLAR VALUE OF THE ACQUISITON.
Procurement is for:
· 421 RTLS/Wi-Fi Asset Tag with Cradle, Plexus Licensing & Tag Activation
· 421 Pc. RTLS Tag Cradle Set with Tap
Procurement cost: $74,938.00
3. IDENTIFICATION OF STATUTORY AUTHORITY PERMITTING OTHER THAN FULL AND OPEN COMPETITION.
X FAR 13.106-1(b) (1): For purchases not exceeding the simplified acquisition threshold (SAT), contracting officers may solicit from one source if the contracting officer determines that the circumstance of the contract action deem only one source reasonably available (e.g. urgency, inclusive licensing agreements, brand name, or industrial mobilization).
4. DEMONSTRATION THAT THE PROPOSED CONTRACTOR’S UNIQUE QUALIFICATIONS OR THE NATURE OF THE ACQUISITION REQUIRES USE OF THE AUTHORITY CITED
Usage in the Clinical Center:
· In 2018, the CC did a pilot on the Stanley-Aeroscout asset tracking system on the 3rd and 5th floor of the Clinical Research Building
· In 2020, the CC introduced an RTLS employee location feature as part of the Rauland Responder 5 Patient Call.
· In 2022, the Property Management Branch of NIH is piloting a Sunflower stationary RFID Fixed Reader system
· In 2022, the NIH awarded an RFID and RTLS system to Conexus
· In 2024, The NIH bought 428 additional RTLS tags
Sole Source: Conexus, Inc. is the only brand that meets the requirements needed for this contract.
No other brand can provide:
· Conexus is the only company authorized to connect RTLS tags to the Plexus asset tracking system. The Securitas RTLS tag is the verified RTLS used by Conexus.
· The Asset Tracking solution is assessed and authorized to operate (ATO) on a DoD network with the Defense Health Agency. The process, which is based on the National Institute of Standards and Technology (NIST) Risk Management Framework (RMF), follows a strict adherence to security from software design to implementation, and requires ongoing reviews, updates, and assessments to ensure that the system has sufficiently designed around and/or mitigated for past, current, and future.
· Mobile scanner that can scan 1,000 ft2 (93m2) per x Span unit with Monza R6 based tags, up to 30ft distance from scanner
· Mobile scanner capable of scanning a coverage area of a 10,000 sq. Ft. in less than 5 minutes with minimal to no room entry or patient disturbance
· The System integrates Barcode, Passive RFID and Active Wi-Fi technologies into a single unified platform. RTLS utilizes the site’s 802.11n (or later) network.
· The System uses a combination of Web, Client, Fixed and Mobile devices capable of communicating real-time asset location across a collection of facilities that can make up a campus of facilities. Connection can be delivered by using the campus LAN or can be done using an authorized HTTPS secure internet connection across disparate networks.
· Demonstrated Third-Party Interface Capability. Ability to Bi-directionally interface with large government databases such as the Defense Medical Logistics Standard Support (DMLSS), which is the master record of accountability throughout Defense Health Agency (DHA).
· RFID Location-Aware – automated scanning of RFID tags that will recognize which room in the facility they are located, rather than the person having to determine the room manually. Capability of assigning a “home” location for an asset. When scanning with RFID (Handheld, Cart or Fixed Reader), it will recognize the location and will assess the items that are present and are NOT present. If an asset is expected to remain in a home location, and the scan determines the asset is not in the home location, that data can be reported.
· System conforms to the prevailing Federal Information Processing Standard (FIPS) data encryption process each time that a data file is prepared for distribution.
· Supports the use of the OEM’s serial number and other equipment control numbers that may be part of the customer’s legacy system.
Sole Source Impact:
· Inconsistent equipment, features, supplies and operations will prevent researchers to follow NIH Protocols. Protocol based care requires absolute consistency and reproducibility in equipment and processes. If any other equipment is considered, the CC will incur risks
· Consistency of applications within the Clinical Center could pose a patient safety issue. Inconsistency of applications also includes a huge increase in labor, time and cost for IT applications and cyber-security reviews and management
· NIH CC safe practice and culture of Standardization of equipment, supplies, user training, maintenance and contract management
· Develop new policy and procedures for implementation, including equipment cleaning and recall/alerts management
· Review the long-term risk of a possible new source of infection
· Review the incompatibility with the current equipment and supplies
5. A DESCRIPTION OF EFFORTS MADE TO ENSURE THAT OFFERS ARE SOLICITED FROM AS MANY POTENTIAL SOURCES AS PRACTIABLE
This is a sole source item. No other brand can provide the requirements listed in question 5.
6. DEMONSTRATION THAT THE ANTICIPATED COST WILL BE FAIR AND REASONABLE
The actual cost of this device is consistent and lower when compared to non-dedicated systems. Cost comparison was measured against past procurements, ECRI market analysis, and industry standards.
7. DESCRIPTION OF MARKET RESEARCH CONDUCTED AND THE RESULTS OR STATEMENT OF THE REASON MARKET RESEARCH WAS NOT CONDUCTED
Researched sources include ECRI equipment comparison and guidance charts; ECRI Select Plus Market Intelligence Reports. Consultation and information gathering from the CC's Standardization Committee members, equipment managers, attendance at AAMI and HIMSS Technology Conference and Expositions.
8. ANY OTHER FACTS SUPPORTING THE USE OF OTHER THAN FULL AND OPEN COMPETITION.
9. LISTING OF SOURCES, IF ANY, THAT EXPRESSED, IN WRITING, AN INTEREST IN THE ACQUISITION.
No other source expressed interest in acquisition.
10. STATEMENT OF THE ACTIONS, IF ANY, THE AGENCY MAY TAKE TO REMOVE OR OVERCOME ANY BARRIERS TO COMPETITION BEFORE ANY SUBSEQUENT ACQUISITION FOR THE REQUIRED SUPPLIES OR SERVICES.
There are currently no barriers
ADMINISTRATIVE OFFICER/PROGRAM OFFICIAL CERTIFICATION
“I hereby certify that the information contained in this justification is accurate and complete to the best of my knowledge and belief.”
David Ram, Supervisory Biomedical Engineer, COR
[YOUR NAME, SIGNATURE, AND TITLE]
Administrative Officer or COR
13. CONTRACTING OFFICER’S CERTIFICATION
“I hereby certify that the information contained in this justification is accurate and complete to the best of my knowledge and belief.”.”
[NAME AND SIGNATURE]
Contracting Officer image1.emf image2.png