2511 LCSS MM Roof_100CD_2026_0227.pdf
PDF 28 MB Posted
- Attached to
- RFP2026-14 Midway Middle School Reroofing
- Solicitation number
- PE-68910-NONST-2026-000000046
- Issued by
- Lanier County, Georgia
About this file
This is a construction documents package for a roof replacement project at Midway Middle School, a facility operated by Liberty County School System in Hinesville, Georgia. The project involves removing and replacing all low-slope roof membranes across approximately 98,191 square feet of existing roof area, along with installing new coping and edge metal at building perimeters, providing new gutters and downspouts, and installing new roof drains at existing locations. The scope of work includes polyvinyl chloride (PVC) roofing installation over existing low-slope roof construction on metal deck, with detailed demolition procedures addressing removal of existing PVC membranes, flashing systems, roof drains, drip edges, gutters, downspouts, coping, and associated flashings. The construction documents include composite roof plans covering multiple building wings (administration, kitchen, media, and classroom wings 200-500), detailed roof construction specifications, wind pressure analysis based on ASCE 7-22 standards with a basic wind speed of 140 miles per hour, and comprehensive installation details for all roof components and penetrations. The documents reference compliance with applicable 2024 International Building Code editions and Georgia amendments, along with various trade-specific standards including SMACNA sheet metal manual guidelines and manufacturer specifications for PVC roofing systems.
The project has been prepared by Cogdell & Mendrala Architects, PC (Project No. 2511, Owner Project Number 2026-14) in conjunction with Saussy Engineering as structural engineers, with documents dated February 2026. The specifications require field verification of all existing conditions and dimensions prior to construction, with contractor responsibility for investigating roof system condition once membranes are removed and notifying the design professional of any damaged or missing insulation. Key construction requirements include maintaining weathertight conditions during work, protecting existing equipment from roofing activities, replacing deteriorated wood blocking under unit cost allowances, and ensuring all exposed unfinished exterior metal surfaces are painted. The documents note that existing roof slopes are to remain unless non-compliant or causing ponding, and existing wood blocking in good condition may remain, with replacement of damaged sections covered under unit pricing provisions.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ITB Letter MMS Roof Replacment.pdf | ||
| LCSS MM REROOF _ Addendum No_01.pdf | ||
| LCSS MM REROOF _ Addendum No_02.pdf | ||
| 2511_MM_ROOF_SPECS_2026_0227.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COGDELL & MENDRALA ARCHITECTS, PC
LCSS MIDWAY MIDDLE SCHOOL
ROOF REPLACEMENT
FACILITY NO.: 689-0101
LIBERTY COUNTY SCHOOL SYSTEM
SAUSSY ENGINEERING
ARCHITECTS
OWNER
LIBERTY COUNTY SCHOOL SYSTEM
200 BRADWELL STREET, HINESVILLE, GA 31313
517 E CONGRESS ST. SAVANNAH, GEORGIA, 31401
912.234.6318
CONSULTANTS
400 JOHNNY MERCER BLVD. SUITE E SAVANNAH, GA 31410
912.898.8255
STRUCTURAL ENGINEERS
SHEET
COPYRIGHT © 2025 COGDELL & MENDRALA ARCHITECTS, PC
ARCH. PROJECT NO.: 2511
OWNER PROJECT NUMBER: 2026-14
/2
/2
:3 :3
P
M A u to d e s k D o c s /2
L C
S S
M M
R e ro o f/
L
C S
S M
M R e ro o f_
R V
T
.r v t
CONSTRUCTION DOCUMENTS
425 EDGEWATER DRIVE MIDWAY, GA 31320
FEBRUARY 2026
T1.0
517 EAST CONGRESS STREET
SAVANNAH, GEORGIA 31401
tel 912.234.6318 fax 912.236.8414 cogdellmendrala.com
SEAL
SHEET TITLE
PROJECT NO:
DRAWN BY:
DATE:
SCALE:
SHEET
KEY PLAN
Casey Brent Smith
G G
IAA
T
T
S
E
EOF OR
ARC H
IT
R
R
G E
I
E E D
ST
E C T
E
E
C
R T
IF ICAT D ON . 49
STRUCTURAL ENGINEERS
TRUE NORTH PROJECT NORTHSCALE
COPYRIGHT © 2025 COGDELL & MENDRALA ARCHITECTS, PC
OWNER NO:
SAUSSY ENGINEERING
400 JOHNNY MERCER BLVD. SUITE E
SAVANNAH, GA 31410
NOT TO SCALE
GYM
FACILITY NO: 689-0101
/2
/2
:3 :3
P
M A u to d e s k D o c s /2
L C
S S
M M
R e ro o f/
L
C S
S M
M R e ro o f_
R V
T
.r v t
G0.01
SHEET LIST
JMJ
FEBRUARY 2026
CONSTRUCTION
DOCUMENTS
LCSS MIDWAY
MIDDLE SCHOOL
ROOF
REPLACEMENT
425 EDGEWATER DRIVE
MIDWAY, GA 31320
LIBERTY COUNTY SCHOOL
SYSTEM
MIDWAY MIDDLE SCHOOL
2026-14
SHEET LIST - ARCHITECTURAL
Sheet Number Sheet Name REV. DATE REV.
A2.01 COMPOSITE ROOF PLAN
A2.02 ROOF PLAN - ADMIN, KITCHEN, & MEDIA
A2.03 ROOF PLAN - CLASSROOM WING 200
A2.04 ROOF PLAN - CLASSROOM WING 300
A2.05 ROOF PLAN - CLASSROOM WING 400
A2.06 ROOF PLAN - CLASSROOM WING 500
A8.31 ROOF DETAILS
A8.32 ROOF DETAILS
SHEET LIST - DEMOLITION
Sheet Number Sheet Name REV. DATE REV.
D2.01 DEMOLITION - ROOF PLAN
SHEET LIST - GENERAL
Sheet Number Sheet Name REV. DATE REV.
G0.01 SHEET LIST
G0.02 GENERAL PROJECT INFORMATION
SHEET LIST - STRUCTURAL
Sheet Number Sheet Name REV. DATE REV.
S1.0 COMPONENTS AND CLADDING WIND ROOF PRESSURES
REVISION SCHEDULE
NO DATE DESCRIPTION
DRAWING
TITLE TITLE OF DRAWING1
A0.1 1/8" = 1'-0"
100A
LOBBY
H100
A0.1 SHEET NO. WHERE
DWG NO.
SHEET NO. WHERE
ELEV. IS DRAWN
SHEET NO. WHERE
DRAWING NO.
SECT. LINESECT. IS DRAWN
SECT. IS DRAWN
DET. IS DRAWN
AREA
AROUND
DASHES
DETAILED
ROOM NAME
ROOM NO.
DOOR NO.
SHEET NO. WHERE
DWG NO.
DWG NO.
DWG NO.
CENTER LINE
DOOR TAG
EXTERIOR WALL TAG
SEE A0.03
MATCH LINE
BREAK LINE
REVISION TAG
DIMENSION
INDICATOR
X.X
16'-0"
BUILDING
SECTION
WALL
SECTION
PLAN OR
SECTION
DETAIL
ROOM TAG
EXTERIOR
ELEVATION
N O
R T H
NORTH
ARROW
A0.1
A0.1
SECT. LINE
A0.1
S1
R1
FLOOR TAG
SEE A0.03
A0.1 A0.1
REVISION CLOUD
REVISION NUMBER
ROOF TAG
SEE A0.03
WINDOW TAG
SEE A8.X SERIES
C1
STOREFRONT TAG
SEE A8.X SERIES
CURTAIN WALL TAG
SEE A8.X SERIES
S1
W1
ROOF TYPE
FLOOR TYPE
EXTERIOR
WALL TYPE
VERTICAL HEIGHT
SPOT ELEVATION
MAIN LEVEL PLAN
0' - 0"
0' - 0"
TOILET & BATH
ACCESSORY TAG
TBA-1
KEYNOTE TAG 03 30 00.A CAST-IN-PLACE CONCRETE
SPECIFICATION SECTION
DESCRIPTION OF CONSTRUCTION
COMPONENT
CONSTRUCTION COMPONENT AS
LISTED IN LEGEND
PLAN NOTE TAG REFERS TO CORRESPONDING
NOTES ON SHEET
ELEV. IS DRAWN
SHEET NO. WHERE
DRAWING NO.INTERIOR
ELEVATION
A0.1 A0.1
INTERIOR PARTITION TAG
SEE A0.04
X.X.X
INTERIOR
WALL TYPE
X.X
X X
REFERS TO CORRESPONDING
ITEM AS SCHEDULED
AIR CONDITION(ING)
ADMINISTRATION
ABOVE FINISHED FLOOR
ALTERNATE
ALUMINUM
APPROXIMATE(LY)
ARCHITECT(URAL)
AUTOMATIC
AUXILIARY
AUDIOVISUAL
BITUMINOUS
BUILDING LINE
BUILDING
BOTTOM OF STEEL
BOTTOM
CABINET
CONTRACTOR FURNISHED,
CONTRACTOR INSTALLED
CONTROL JOINT
CENTER LINE
CEILING
CEILING HEIGHT
CLOSET
CLEAR(ANCE)
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
CONFERENCE
CONTINUE, CONTINUOUS
CORRIDOR
CUBIC FOOT
CUBIC YARD
DEMOLISH
DEPARTMENT
DETAIL
DRINKING FOUNTAIN
DIAMETER
DIAGONAL
DIMENSION
DIVISION
DOWN SPOUT
EAST
EACH
ELEVATION
ELECTRIC(AL)
ELEVATOR
EXPANSION JOINT
ENCLOSE(D)
EDGE OF SLAB
EQUAL
EQUIPMENT
ELECTRIC WATER COOLER
EXISTING
JT EXPANSION JOINT
EXTERIOR
FLOOR DRAIN
FIRE EXTINGUISHER
FIRE EXTINGUISHER ON
BRACKET
FIRE EXTINGUISHER CABINET
FACE TO FACE
FINISH FLOOR ELEVATION
FIRE HOSE CABINET
FINISHED FLOOR
FLOOR, FILLER
FACE OF CURB
FACE OF FINISH
FACE OF MASONRY
FACE OF SLAB
FACE OF WALL
FOOT, FEET
FOOTING
FURNISH, FURNITURE
GAGE
GALVANIZED
GENERAL CONTRACTOR
GYPSUM BOARD
GYPSUM PLASTER
HANDICAP
HEAVY DUTY
HARDWARE
HARDWOOD
HOLLOW METAL
HORIZONTAL
HEIGHT
HEATING, VENTILATION &
AIR CONDITIONING
INSIDE DIAMETER
INFORMATION
INCLUDE(D), (ING)
INSULATION
INTERIOR
JANITOR CLOSET
KITCHEN
KNOCKOUT
LABORATORY
LAMINATE
LAUNDRY
LAV LAVATORY
LF LINEAR FEET
LVR LOUVER
MAINTENANCE
MATERIAL
MAXIMUM
MECHANICAL
MEZZANINE
MANUFACTURING
MANUFACTURER
MINIMUM
MISCELLANEOUS
MASONRY OPENING
MOISTURE RESISTANT
MOUNTED
MOUNTING
METAL
NORTH
NOT IN CONTRACT
NON-COMBUSTIBLE
NOMINAL
NOT TO SCALE
ON CENTER
OUTSIDE DIAMETER
OWNER FURNISHED,
CONTRACTOR INSTALLED
OWNER FURNISHED, OWNER
INSTALLED
OPTION(AL)
OPPOSITE
POUNDS PER CUBIC FEET
PLASTIC LAMINATE
POUNDS PER LINEAR FOOT
PLYWOOD
PANEL
PAIR
PREFABRICATED
PREFINISH
PARKING
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
PAINT, POST-TENSIONED,
PRE-TREATED
POLYVINYL CHLORIDE
(PLASTIC)
QUARTER
QUANTITY
RADIUS, RISER
REFLECTED CEILING PLAN,
REINFORCED CONCRETE
PIPE
ROOF DRAIN
REFRIGERATOR, REFERENCE
REQUIRED
ROOF LEADER
ROOM
ROUGH OPENING
RIGHT OF WAY
S SOUTH
SC SOLID CORE
SD STORM DRAIN
SECT SECTION
SF SQUARE FEET
SIM SIMILAR
SPEC SPECIFICATION
SPKR SPEAKER
SQ SQUARE
SS STAINLESS STEEL
STANDARD
STORAGE
SUSPENDED
SYSTEM
TREAD
TELEPHONE
TEMPORARY
TOP OF FINISH FLOOR
THICKNESS
THROUGH
TOP OF BEAM
TOP OF CONCRETE, TOP OF CURB
TOP OF FOOTING
TOP OF JOIST
TOP OF MASONRY
TOP OF PARAPET
TOS TOP OF SLAB
TOW TOP OF WALL
TREATED
TELEVISION
TYPICAL
UNDERWRITERS LABORATORIES
UNLESS NOTED OTHERWISE
VERTICAL
VESTIBULE
VERIFY IN FIELD
WEST, WIDE
WITH
WITHOUT
WATER CLOSET
WOOD
WORKING POINT, WATERPROOFING
WATER REPELLENT
WEIGHT
WALL TO WALL
WELDED WIRE FABRIC
YARD
A/C
ADMIN
AFF
ALT
ALUM
APPROX
ARCH
AUTO
AUX
AV
BITUM
BL
BLDG
BOS
BOT
CAB
CFCI
CJ
CL
CLG
CLG HT
CLO
CLR
CMU
COL
CONC
CONF
CONT
CORR
CU FT
CU YD
DEMO
DEPT
DET
DF
DIA
DIAG
DIM
DIV
DS
E
EA
EL
ELEC
ELEV
EJ
ENCL
EOS
EQ
EQUIP
EWC
EXIST
EXP JT
EXT
FD
FE
FEB
FEC
F/F
FF EL
FHC
FIN FLR
FLR
FOC
FOF
FOM
FOS
FOW
FT
FTG
FURN
GA
GALV
GC
GYP BD
GYP PLAS
HC
HD
HDWR
HDWD
HM
HORIZ
HT
HVAC
ID
INFO
INCL
INSUL
INT
JAN CLO
KIT
KO
LAB
LAM
LAU
LAV
LF
LVR
MAINT
MATL
MAX
MECH
MEZZ
MFG
MFR
MIN
MISC
MO
MR
MTD
MTG
MTL
N
NIC
NON
NOM
NTS
OC
OD
OFCI
OFOI
OPT
OPP
PCF
PLAM
PLF
PLYWD
PNL
PR
PREFAB
PREFIN
PRKG
PSF
PSI
PT
PVC
QTR
QTY
R
RCP
RD
REF
REQD
RL
RM
RO
ROW
S
SC
SD
SECT
SF
SIM
SPEC
SPKR
SQ
SS
STD
STOR
SUSP
SYS
T
TEL
TEMP
TFF
THK
THRU
TOB
TOC
TOF
TOJ
TOM
TOP
TOS
TOW
TRTD
TV
TYP
UL
UNO
VERT
VEST
VIF
W W/ W/O
WC
WD
WP
WR
WT
W/W
WWF
YD
EARTH/COMPACT FILL
POROUS FILL
CONCRETE
SAND, GYPSUM BOARD
MORTAR, PLASTER
CONCRETE MASONRY
ROUGH WOOD
WOOD BLOCKING
PLAN LEGEND
SECTION
BATT INSULATION
RIGID INSULATION
BRICK VENEER
STEEL/OTHER METALS
PLYWOOD
GYPSUM BOARD
ACOUSTICAL CLG. TILE
FINISH WOOD
NOT IN CONTRACT
AREA NOT IN SCOPE
METAL STUD
PARTITION
CONCRETE MASONRY
PARTITION
EXISTING
CONSTRUCTION
CONSTRUCTION TO BE
REMOVED
PROPERTY ADDRESS: MIDWAY MIDDLE SCHOOL
425 EDGEWATER DRIVE
MIDWAY, GA 31320
APPLICABLE BUILDING CODES WITH GEORGIA AMENDMENTS:
(LIST IS NOT INCLUSIVE)
1. INTERNATIONAL BUILDING CODE, 2024 EDITION, WITH GEORGIA
AMENDMENTS (2026)
2. INTERNATIONAL FIRE CODE, 2024 EDITION, WITH GEORGIA
AMENDMENTS, (2025)
3. INTERNATIONAL PLUMBING CODE, 2024 EDITION, WITH GEORGIA
AMENDMENTS (2026)
4. INTERNATIONAL MECHANICAL CODE, 2024 EDITION, WITH
GEORGIA AMENDMENTS (2026)
5. INTERNATIONAL FUEL GAS CODE, 2024 EDITION, WITH GEORGIA
AMENDMENTS (2026)
6. NATIONAL ELECTRICAL CODE, 2023 EDITION WITH GEORGIA
AMENDMENTS (2026)
7. INTERNATIONAL ENERGY CONSERVATION CODE, 2015 EDITION,
WITH GEORGIA SUPPLEMENTS AND AMENDMENTS (2020), (2022),
(2023)
8. LIFE SAFETY CODE, NFPA 101, 2024 EDITION WITH GEORGIA
AMENDMENTS
9. NFPA 72 NATIONAL FIRE ALARM & SIGNALING CODE (2022) WITH
GA AMENDMENTS
10. NFPA 13 (2019) WITH GEORGIA AMENDMENTS (2020)
11. DOJ 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN, WITH
GEORGIA ACCESSIBILITY CODE 120-3-20
GROSS ENCLOSED PROJECT
AREA:
98,191 SF
(EXISTING LOW SLOPE
ROOF AREA)
SITE LOCATION
THE PROJECT SCOPE CONSISTS OF REMOVING AND REPLACING ALL
LOW-SLOPED ROOF MEMBRANES, PROVIDING NEW COPING/EDGE METAL
AT BUILDING PERIMETER, PROVIDING NEW GUTTERS AND DOWNSPOUTS,
AND INSTALLING NEW ROOF DRAINS AT EXISTING LOCATIONS.
LOW-SLOPE ROOF CONSTRUCTION ON METAL DECK
R1
07 54 19POLYVINYL CHLORIDE ROOFING
EXISTING LWIC SYSTEM
EXISTING STEEL DECK
EXISTING STEEL STRUCTURE
NOTE:
PROVISIONS OF 07 01 50.19 "PREPARATION FOR
RE-ROOFING" APPLY TO AREAS DENOTED AS "R1".
07 54 19.B15SEPARATION LAYER
517 EAST CONGRESS STREET
SAVANNAH, GEORGIA 31401
tel 912.234.6318 fax 912.236.8414 cogdellmendrala.com
SEAL
SHEET TITLE
PROJECT NO:
DRAWN BY:
DATE:
SCALE:
SHEET
KEY PLAN
Casey Brent Smith
G G
IAA
T
T
S
E
EOF OR
ARC H
IT
R
R
G E
I
E E D
ST
E C T
E
E
C
R T
IF ICAT D ON . 49
STRUCTURAL ENGINEERS
TRUE NORTH PROJECT NORTHSCALE
COPYRIGHT © 2025 COGDELL & MENDRALA ARCHITECTS, PC
OWNER NO:
SAUSSY ENGINEERING
400 JOHNNY MERCER BLVD. SUITE E
SAVANNAH, GA 31410
NOT TO SCALE
GYM
FACILITY NO: 689-0101
As indicated
/2
/2
:1
:4
A
M A u to d e s k D o c s /2
L C
S S
M M
R e ro o f/
L
C S
S M
M R e ro o f_
R V
T
.r v t
G0.02
GENERAL
PROJECT
INFORMATION
JMJ
FEBRUARY 2026
CONSTRUCTION
DOCUMENTS
LCSS MIDWAY
MIDDLE SCHOOL
ROOF
REPLACEMENT
425 EDGEWATER DRIVE
MIDWAY, GA 31320
LIBERTY COUNTY SCHOOL
SYSTEM
MIDWAY MIDDLE SCHOOL
2026-14
GRAPHIC SYMBOLS
ABBREVIATIONS
GENERAL NOTES
1 REFER TO SHEET G0.02 FOR SYMBOL LEGEND.
2 ALL LUMBER AND PLYWOOD INSTALLED THROUGHOUT THE BUILDING SHALL BE FIRE-RETARDANT
TREATED. STANDING AND RUNNING TRIM DO NOT REQUIRE TREATMENT.
3 REFER TO PLANS AND/OR SECTIONS FOR SUBSYSTEM TYPE
4 ALL EXPOSED, UNFINISHED EXTERIOR METAL SURFACES SHALL BE PAINTED.
5 NEW FINISHES SHALL BE INSTALLED FLUSH WITH EXISTING FINISHES.
6 WHERE A NOTE/DETAIL IS SHOWN FOR ONE CONDITION, IT SHALL APPLY TO ALL SIMILAR AND LIKE
CONDITIONS, UNLESS NOTED OTHERWISE.
7 UNPAINTABLE SILICONE SEALANTS ARE NOT PERMITTED. ALL SEALANTS TO BE TYPE NP-1 OR AS
RECOMMENDED BY ROOFING MANUFACTURER. UNLESS NOTED OTHERWISE.
8 ALL EXTERIOR WOOD BLOCKING AND PLYWOOD TO BE PRESSURE TREATED U.N.O.
9 ALL EXPOSED, UNPREFINISHED EXTERIOR METAL SURFACES SHALL BE PAINTED.
10 ALL EXISTING DIMENSIONS SHALL BE VIF.
MATERIAL LEGEND GENERAL INFORMATIONSITE LOCATION
PROJECT SUMMARY
KEYNOTE LEGEND - MASTER
NO. NOTE
05 50 00.A8 METAL DOWNSPOUT BOOT W/CLEANOUT
06 10 53.A1 P.T. WD. BLOCKING
06 10 53.A2 WD. BLOCKING AS REQD.
06 10 53.F12 P.T. 2X10
06 10 53.H8 1/2" P.T. PLYWOOD
07 54 19 POLYVINYL CHLORIDE ROOFING
07 54 19.A3 TERM. BAR
07 54 19.A7 MANUFACTURED RETROFIT DRAIN
07 54 19.B2 FLASHING MEMBRANE
07 54 19.B4 REINFORCED MEMBRANE UP & OVER PARAPET
07 54 19.B5 BASE FLASH
07 54 19.B10 PVC WALK-OFF PAD
07 54 19.B15 SEPARATION LAYER
07 54 19.C6 GYPSUM COVERBOARD
07 54 19.D2 PVC COATED METAL DRIP EDGE
07 54 19.D22 PREFABRICATED PVC CLAD METAL SCUPPER
07 54 19.I PREFABRICATED STACK/PIPE BOOT AND CLAMP
07 62 00.J1 COUNTERFLASHING W/ CONT. CLEAT
07 62 00.J2 COUNTERFLASHING
07 62 00.M1 SELF ADHERING UNDERLAYMENT
07 71 00.C7 DRIP EDGE
07 71 00.C52 MANUF. ROOF EDGE FASCIA 5 1/4"
07 71 00.E4 DOWNSPOUT
07 71 00.E10 GUTTER BRACKET AT 32" O.C., ALTERNATE WITH STRAPS
07 71 00.H GUTTER
07 71 00.H51 GUTTER STRAP AT 32" O.C.
07 92 00.A1 SEALANT
07 92 00.A6 SEALANT AND BACKER ROD
09 91 13 EXTERIOR PAINTING
TAGDESCRIPTION FIRE RATING REFERENCE
ROOF TYPES
EXISTING TO REMAIN - NOT IN CONTRACT
EXISTING TO REMAIN -
NOT IN CONTRACT
EXISTING TO REMAIN -
NOT IN CONTRACT
T Y
P
IC
A L
T Y
P
IC
A L
10' - 0"
10' - 0"
10' - 0"
10' - 0"
10' - 0" 10' - 0"
10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0" 10' - 0"
211'
1'
1'
1'
1'
1'
1'
2 1 21
2 1
2 1 21
2 1
3 3
3 3
S1.0
A TYP
NOTE:
ALL WIND LOADING SHOWN HEREIN ARE UNFACTORED BASED ON
ASCE-7-22 BASIC WIND SPEED (3 SECOND GUST) WHICH IS EQUIVALENT
TO IBC 2024 ULTIMATE DESIGN WIND SPEED.
BASIS OF DESIGN
A. WIND LOADS (REFERENCE: ASCE 7-22)
BASIC WIND SPEED (3 SECOND GUST), V = 140 MPH (FIGURE 26.5-1B)
NOMINAL WIND SPEED, Vasd = 108 MPH
RISK CATEGORY = III (TABLE 1.5-1)
EXPOSURE CATEGORY = C (SECTION 26.7)
INTERNAL PRESSURE COEFFICIENTS: +0.18,-0.18 (TABLE 26.13-1)
(ENCLOSED BUILDING TYPE)
ZONE
TRIBUTARY
AREA (SQFT)
PRESSURE (PSF)
POSITIVE NEGATIVE OVERHANG
COMPONENTS AND CLADDING ROOF SURFACE PRESSURES
-91.0 -83.7 -72.7 -65.3 -58.0 -47.0 -47.0
-91.0 -85.5 -78.2 -72.7 -65.3 -58.0 -58.0
17.6 16.7 16.0 16.0 16.0 16.0 16.0
17.6 16.7 16.0 16.0 16.0 16.0 16.0
-69.0 -65.3 -58.0 -54.3 -50.6 -43.3 -43.3
-69.0 -67.2 -66.2 -65.3 -54.3 -43.3 -43.3
-124.0 -111.2 -92.9 -78.2 -65.3 -47.0 -47.0
-124.0 -113.0 -98.4 -83.7 -72.7 -58.0 -58.0
17.6 16.7 16.0 16.0 16.0 16.0 16.0
17.6 16.7 16.0 16.0 16.0 16.0 16.0
-39.6 -39.6 -39.6 -39.6 -34.1 -26.8 -21.3
-69.0 -67.2 -66.2 -65.3 -54.3 -43.3 -43.3
1'
10' - 0" 10' - 0"
1'
3' - 6"
10' - 0"
Not Valid Unless Signed
IRG
ED
TSIG ER
A
R
E G
No. 000432
E
O
I
,YN ER
SUSR A
G ENI
S
W H
T
U
N
STRUCTURAL
E
E
I I
SAUSSY ENGINEERING
400 Johnny Mercer Boulevard Suite E
P.O. Box 30597 Savannah, Georgia 31410
Phone: (912) 898-8255 Fax: (912) 898-1882
517 EAST CONGRESS STREET
SAVANNAH, GEORGIA 31401
tel 912.234.6318 fax 912.236.8414 cogdellmendrala.com
SEAL
SHEET TITLE
PROJECT NO:
DRAWN BY:
DATE:
SCALE:
SHEET
KEY PLAN
STRUCTURAL ENGINEERS
TRUE NORTH PROJECT NORTHSCALE
COPYRIGHT © 2026 COGDELL & MENDRALA ARCHITECTS, PC
OWNER NO:
SAUSSY ENGINEERING
400 JOHNNY MERCER BLVD. SUITE E
SAVANNAH, GA 31410
NOT TO SCALE
PROJECT NO.
2026-14
FACILITY NO: 689-0101
As indicated
/1
/2
:2 :2
P
M F
J O
B S
\O
T H
E R
S \2
-M id w a y M
S L o w
S lo p e R o o f R e p la c e m e n t\ -R e v it \2
M id w a y M
S R o o f R e p la c e m e n t_
S T
R U
C R
.r v t
S1.0
COMPONENTS
AND CLADDING
WIND ROOF
PRESSURES
FEBRUARY 2026
CONSTRUCTION
DOCUMENTS
LCSS MIDWAY
MIDDLE SCHOOL
ROOF
REPLACEMENT
26012
JCG
425 EDGEWATER DRIVE
MIDWAY, GA 31320
LIBERTY COUNTY SCHOOL
SYSTEM
MIDWAY MIDDLE SCHOOL
SCALE: 3/64" = 1'-0"
COMPONENTS AND CLADDING WIND PRESSURE ZONE
DIAGRAM
REVISION SCHEDULE
NO DATE DESCRIPTION
SCALE: 1/4" = 1'-0"S1.0
TYPICAL OUTSIDE CORNER ZONE DETAILA
R - 1R - 1
R - 1
R - 1
R - 1
R - 1 R - 1
R - 2R - 2
R - 2
R - 2
R - 2
R - 2 R - 2
R - 3
R - 3
R - 3
R - 3
R - 3
R - 3
R - 5
R - 6
R - 5
R - 6 R - 5
R - 6
R - 5
R - 6
R - 5
R - 6
R - 5
R - 6
R - 5
R - 6
R - 5
R - 6
R - 5
R - 6
R - 4
R - 4
R - 10
R - 4
R - 4
R - 4
R - 4
R - 4
R - 4
R - 4
R - 4
R - 4
R - 4R - 4
R - 4
R - 4 R - 4
1" E.J.
R - 7
1" E.J.
R - 7
1" E.J.
R - 7
1" E.J.
R - 7
R - 8
R - 8
R - 8
R - 8
R - 8
R - 10
R - 10
R - 4
R - 9
R - 9 R - 9
R - 9
R - 9
R - 9
EXISTING TO REMAIN
NOT IN CONTRACT
EXISTING TO REMAIN
NOT IN CONTRACT
EXISTING TO REMAIN
NOT IN CONTRACT
R - 12
R - 11
R - 1
R - 2
R - 11
R - 11
R - 11
R - 11
R - 11
R - 11 R - 11
R - 10
R - 10R - 4
R - 10
R - 10
R - 10
R - 10
R - 10
R - 10
R - 10
R - 10
R - 10
R - 10
R - 10
R - 10
R - 10
R - 10
R - 10 R - 10
07 54 19 POLYVINYLCHLORIDE (PVC) ROOFING
07 54 19 POLYVINYLCHLORIDE (PVC) ROOFING WALKPAD
EXHAUST FAN WITH MANUFACTURED CURB
ROOF DRAIN
X"/1'-0" DIRECTION OF ROOF PITCH
DOWNSPOUTDS
VTR
NOT IN CONTRACT
R.D.
TO THE BEST OF OUR KNOWLEDGE, THE FOLLOWING INFORMATION IS CORRECT. THE CONTRACTOR
IS RESPONSIBLE FOR VERIFICATION OF EXISTING CONDITIONS.
1. EXISTING PVC ROOF SYSTEM:
PVC MEMBRANE OVER LWIC (VERMICULITE) OVER STRUCTURAL STEEL DECK.
2. EXISTING ROOF SYSTEM INFORMATION IS BASED ON EXISTING BUILDING DOCUMENTATION.
CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS.
517 EAST CONGRESS STREET
SAVANNAH, GEORGIA 31401
tel 912.234.6318 fax 912.236.8414 cogdellmendrala.com
SEAL
SHEET TITLE
PROJECT NO:
DRAWN BY:
DATE:
SCALE:
SHEET
KEY PLAN
Casey Brent Smith
G G
IAA
T
T
S
E
EOF OR
ARC H
IT
R
R
G E
I
E E D
ST
E C T
E
E
C
R T
IF ICAT D ON . 49
STRUCTURAL ENGINEERS
TRUE NORTH PROJECT NORTHSCALE
COPYRIGHT © 2025 COGDELL & MENDRALA ARCHITECTS, PC
OWNER NO:
SAUSSY ENGINEERING
400 JOHNNY MERCER BLVD. SUITE E
SAVANNAH, GA 31410
NOT TO SCALE
GYM
FACILITY NO: 689-0101
As indicated
/2
/2
:3 :3
P
M A u to d e s k D o c s /2
L C
S S
M M
R e ro o f/
L
C S
S M
M R e ro o f_
R V
T
.r v t
D2.01
DEMOLITION -
ROOF PLAN
JMJ
FEBRUARY 2026
CONSTRUCTION
DOCUMENTS
LCSS MIDWAY
MIDDLE SCHOOL
ROOF
REPLACEMENT
425 EDGEWATER DRIVE
MIDWAY, GA 31320
LIBERTY COUNTY SCHOOL
SYSTEM
MIDWAY MIDDLE SCHOOL
2026-14
3/64" = 1'-0"D2.01
DEMOLITION - ROOF PLAN1
DEMO NOTES - ROOFS
ROOF
R-1 REMOVE PVC MEMBRANE. EXISTING LWIC ROOF SYSTEM TO REMAIN.
R-2 REMOVE FLASHING SYSTEMS, INCLUDING FLASHING AT PENETRATIONS AND CURBS. COORDINATE
DEMOLITION OF EXISTING CONSTRUCTION WITH NEW MATERIAL INSTALLATION.
R-3 REMOVE ROOF DRAINS AND ASSOCIATED FLASHINGS.
R-4 REMOVE DRIP EDGE, GUTTERS AND DOWNSPOUTS.
R-5 EXISTING HVAC EQUIPMENT AND CURBS TO REMAIN. REMOVE CURB FLASHING. REMOVE HVAC EQUIPMENT AS NEEDED TO REPLACE CURB FLASHING. COORDINATE REMOVAL AND ANY UNIT OFFLINE
TIME WITH OWNER. EVALUATE CURBS AND REMOVE DAMAGED SECTIONS. SEE UNIT PRICES.
R-6 REMOVE ALL ABANDONED ROOF PENETRATIONS AND FLASHING. COORDINATE WITH OWNER.
R-7 DO NOT DISTURB RATED INTERIOR EXPANSION JOINT MATERIALS. IF EXPANSION JOINT MATERIAL IS
DAMAGED OR MISSING, NOTIFY DESIGN PROFESSIONAL. SEE NEW CONSTRUCTION DETAILS FOR
EXPANSION JOINT DETAILS.
R-8 REMOVE THROUGH-WALL SCUPPERS AND FLASHING.
R-9 REMOVE COPING AND ASSOCIATED FLASHINGS. EXAMINE AND EVALUATE EXISTING BLOCKING. REMOVE
DAMAGED SECTIONS. SEE UNIT PRICES.
R-10 REMOVE DOWNSPOUT BOOTS.
R-11 REMOVE ALL EXISTING ABANDONED CURB CAPS.
R-12 REMOVE GUTTER AND ANY DAMAGED FASCIA.
GENERAL DEMOLITION NOTES
1 DEMOLITION PROCEDURES SHALL BE PERFORMED IN ACCORDANCE WITH NFPA 241, 2022 EDITION
"STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS".
2 WHERE A NOTE/DETAIL IS SHOWN FOR ONE CONDITION, IT SHALL APPLY TO ALL SIMILAR AND LIKE
CONDITIONS.
3 ANY EQUIPMENT REMOVED FOR RE-INSTALLATION SHALL BE PROTECTED AND STORED BY THE
CONTRACTOR.
4 WHERE MATERIALS ARE REMOVED OR DEMOLISHED, INFILL OR PATCH TO MATCH EXISTING
ADJACENT FINISH AND/OR STRUCTURAL MEMBER.
5 REMOVE ONLY THE PORTION OF THE ROOF SYSTEM THAT CAN BE REINSTALLED THAT WORK DAY, UNLESS PRIOR WRITTEN APPROVAL FROM THE OWNER HAS BEEN OBTAINED. IF NEW ROOFING
INSTALLATION CANNOT BE COMPLETED PRIOR TO END OF WORK DAY, COVER AND PROTECT
EXPOSED ROOF SHEATHING AND STRUCTURE TO KEEP BUILDING WEATHERTIGHT AND WATERTIGHT.
6 DEMOLITION ACTIVITIES SHALL COMPLY WITH SPECIFICATION SECTION 07 01 50.19 "PREPARATION
FOR REROOFING" AND AS INDICATED IN THE DRAWINGS.
7 ALL EQUIPMENT TO REMAIN SHALL BE PROTECTED FROM DEMOLITION ACTIVITIES.
ROOF LEGEND
EXISTING ROOF NOTES
07 54 19 POLYVINYLCHLORIDE (PVC) ROOFING
07 54 19 POLYVINYLCHLORIDE (PVC) ROOFING WALKPAD
EXHAUST FAN WITH MANUFACTURED CURB
ROOF DRAIN
X"/1'-0" DIRECTION OF ROOF PITCH
DOWNSPOUTDS
VTR
NOT IN CONTRACT
R.D.
A2.02
A2.03
A2.04
A2.05
A2.06
EXISTING TO REMAIN
NOT IN CONTRACT
EXISTING TO REMAIN
NOT IN CONTRACT
1" E.J.
1" E.J.
1" E.J.
1" E.J.
EXISTING TO REMAIN
NOT IN CONTRACT
INSTALL NEW PVC MEMBRANE. INSTALL NEW FLASHINGS, INCLUDING AT PENETRATIONS AND CURBS.
SEE DETAILS.
INSTALL NEW FLASHING AT EXISTING HVAC UNIT CURBS. REMOVE HVAC EQUIPMENT AS NEEDED TO
REPLACE CURB FLASHING. REPLACE SECTIONS OF DAMAGED CURBS. SEE UNIT PRICES.
INSTALL NEW ROOF DRAINS AND ASSOCIATED FLASHINGS AT EXISTING DRAIN LOCATIONS.
FIELD VERIFY DRAIN DIMENSIONS. NEW ROOF DRAINS TO MATCH EXISTING SIZES. REFER TO DETAILS.
INSTALL NEW PREFABRICATED PVC COATED THROUGH-WALL SCUPPERS AND FLASHING.
FIELD VERIFY SCUPPER DIMENSIONS.
INFILL DECK AND INSULATION (FLUSH) AT ABANDONED ROOF PENETRATIONS. INFILL MATERIAL TO
MATCH EXISTING ADJACENT ROOFING IN THICKNESS AND MATERIAL.
DO NOT DISTURB RATED INTERIOR EXPANSION JOINT MATERIALS. IF EXPANSION JOINT MATERIAL IS
DAMAGED OR MISSING, NOTIFY DESIGN PROFESSIONAL. SEE NEW CONSTRUCTION DETAILS FOR
EXPANSION JOINT DETAILS.
INSTALL NEW FASCIA WITH DRIP EDGE. SEE DETAILS.
FASCIA/DRIP EDGE TO MATCH EXISTING MATERIAL, FINISH, PROFILE AND DIMENSIONS.
INSTALL NEW GUTTERS AND DOWNSPOUTS. GUTTERS/DOWNSPOUTS TO MATCH EXISTING IN
MATERIAL, FINISH, PROFILE AND DIMENSIONS.
INSTALL NEW DOWNSPOUT BOOTS. DOWNSPOUT BOOTS TO TIE INTO EXISTING UNDERGROUND
STORM PIPING. DOWNSPOUT BOOTS TO MATCH EXISTING IN MATERIAL, FINISH AND DIMENSIONS.
INSTALL NEW EDGE METAL FASCIA TRIM AND ASSOCIATED FLASHINGS AT PARAPET CONDITIONS.
INSTALL 2'-0" x 3'-0" MIN. PVC WALK-OFF PADS AT EACH BOTTOM OF EACH DOWNSPOUT AT LOW-
SLOPE ROOF.
EXISTING ANTENNA TO REMAIN.
REPLACE ANY DAMAGED FASCIA AND MAKE WATERTIGHT CONNECTION. INSTALL 2'-0" x 3'-0" PVC
WALK-OFF PAD FULL LENGTH OF DRIP LINE.
517 EAST CONGRESS STREET
SAVANNAH, GEORGIA 31401
tel 912.234.6318 fax 912.236.8414 cogdellmendrala.com
SEAL
SHEET TITLE
PROJECT NO:
DRAWN BY:
DATE:
SCALE:
SHEET
KEY PLAN
Casey Brent Smith
G G
IAA
T
T
S
E
EOF OR
ARC H
IT
R
R
G E
I
E E D
ST
E C T
E
E
C
R T
IF ICAT D ON . 49
STRUCTURAL ENGINEERS
TRUE NORTH PROJECT NORTHSCALE
COPYRIGHT © 2025 COGDELL & MENDRALA ARCHITECTS, PC
OWNER NO:
SAUSSY ENGINEERING
400 JOHNNY MERCER BLVD. SUITE E
SAVANNAH, GA 31410
NOT TO SCALE
GYM
FACILITY NO: 689-0101
As indicated
/2
/2
:3 :3
P
M A u to d e s k D o c s /2
L C
S S
M M
R e ro o f/
L
C S
S M
M R e ro o f_
R V
T
.r v t
A2.01
COMPOSITE
ROOF PLAN
JMJ
FEBRUARY 2026
CONSTRUCTION
DOCUMENTS
LCSS MIDWAY
MIDDLE SCHOOL
ROOF
REPLACEMENT
425 EDGEWATER DRIVE
MIDWAY, GA 31320
LIBERTY COUNTY SCHOOL
SYSTEM
MIDWAY MIDDLE SCHOOL
2026-14
KEYNOTE LEGEND - BY SHEET
NO. NOTE
GENERAL ROOF PLAN NOTES
1 WHERE A NOTE/DETAIL IS SHOWN FOR ONE CONDITION IT SHALL APPLY TO ALL SIMILAR AND LIKE
CONDITIONS, UNLESS NOTED OTHERWISE.
2 NOT ALL PENETRATIONS ARE SHOWN ON ROOF PLAN. NOTIFY ARCHITECT OF ANY PENETRATIONS
NOT SHOWN ON ROOF PLAN TO COORDINATE FINAL LOCATIONS.
3 WHERE SLOPE (X/X" / 1'-0") IS NOT INDICATED, SLOPE ROOF MIN. 1/4" PER FOOT. PROVIDE SHOP
DRAWINGS INDICATING ACTUAL SLOPES.
4 AT PENETRATIONS IN 07 54 19 POLYVINYLCHLORIDE (PVC) ROOFING , PROVIDE MANUFACTURER'S
STANDARD FLASHING - TO BE INCLUDED IN WARRANTY.
5 INSTALL ALL SHEET METAL FLASHINGS AT ROOF PENETRATIONS IN ACCORDANCE WITH SMACNA
SHEET METAL MANUAL, CURRENT EDITION.
6 ALL ROOF CURBS TO BE INSTALLED BY ROOFING CONTRACTOR.
7 INSTALL CAST IRON BOOTS AT BOTTOM OF ALL DOWNSPOUTS TIED TO UNDERGROUND STORM
PIPING. PAINT TO MATCH DOWNSPOUTS.
8 PROVIDE CRICKETS ON THE HIGH SIDE OF ALL CURBS EXCEEDING 30" IN WIDTH.
9 SLOPE ALL CRICKETS MINIMUM 1/4" PER FOOT, UNLESS NOTED OTHERWISE.
10 INSTALL FLASHING AT ALL ROOF PENETRATIONS.
11 GUTTERS SHALL BE SLOPED TOWARDS DOWNSPOUTS.
12 DOWNSPOUTS TO MATCH EXISTING IN SIZE AND FINISH, UNLESS NOTED OTHERWISE.
13 TOPS OF ROOF CURBS TO BE LEVEL.
14 FIELD VERIFY ALL EXISTING ITEMS THAT ARE TO BE REPLACED, INCLUDING ROOF DRAINS, EXPANSION
JOINT COVERS, PRIOR TO SHOP DRAWINGS/SUBMITTALS.
15 TOPS OF CURBS AND PENETRATIONS TO BE MINIMUM 8" ABOVE ROOF SURFACE. EXTEND CURBS AND
PENETRATIONS TO ACHIEVE 8" MINIMUM.
16 EXISTING ROOF SLOPES TO REMAIN. CONTACT DESIGN PROFESSIONAL IF EXISTING SLOPE IS NOT
CODE COMPLIANT OR IS RESULTING IN PONDING.
17 EXISTING BLOCKING IN GOOD CONDITION MAY REMAIN. DETERIORATED WOOD BLOCKING SHALL BE
REPLACED UNDER UNIT COST.
18 WHERE BLOCKING IS INSTALLED OVER MASONRY, UNDERLAY WITH 30# FELT AND PROVIDE 1/2"
CHEMICAL ANCHORS UNDER UNIT COST.
19 ONCE MEMBRANE IS REMOVED, ROOFING CONTRACTOR TO INVESTIGATE CONDITION OF EXISTING ROOF SYSTEM AND NOTIFY DESIGN PROFESSIONAL IF LWIC AND/OR INSULATION IS DAMAGED OR
MISSING AND REQUIRES REPLACEMENT. (SEE UNIT PRICES AND ALLOWANCES).
20 ALL EQUIPMENT TO REMAIN SHALL BE PROTECTED FROM ROOFING ACTIVITIES.
21 ALL EXPOSED, UNPREFINISHED EXTERIOR METAL SURFACES SHALL BE PAINTED.
22 PROVIDE ROOF PROTECTION PAD AT TOP AND BOTTOM OF ALL ROOF ACCESS LADDERS OR ACCESS
DOORS/HATCHES.
ROOF LEGEND
3/64" = 1'-0"A2.01
COMPOSITE ROOF PLAN1
ROOF PLAN NOTES
REVISION SCHEDULE
NO DATE DESCRIPTION
PROVIDE 3'-0" CLEARANCE
FROM EQUIPMENT TYP.
PROVIDE 3'-0" CLEARANCE
FROM EQUIPMENT TYP.
EXHAUST FAN WITH MANUFACTURED CURB
ROOF DRAIN
X"/1'-0" DIRECTION OF ROOF PITCH
DOWNSPOUTDS
VTR
NOT IN CONTRACT
R.D.
/4
1/2" / 1'-0" 1/2" / 1'-0"
/4
/4
1/2" / 1'-0"
/4
1/2" / 1'-0"
1/4" / 1'-0" 1/4" / 1'-0"
/4
1/4" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0" 1/4" / 1'-0"
/4
/4
1/4" / 1'-0"
/4
1/2" / 1'-0"
/4
1/2" / 1'-0"
/4
/4
1/4" / 1'-0"
/4
1/4
'-0
1/2" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0"
/4
/4
/4
1/4" / 1'-0" 1/4" / 1'-0"
/4
1/4" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0"
/4
WING 200
ADMIN, KITCHEN,
& MEDIA
WING 300
ADMIN, KITCHEN,
& MEDIA
W
ING 400
ADMIN, KITCHEN,
& MEDIA
WING 500 ADMIN, KITCHEN,
& MEDIA
NOT IN CONTRACT
1" E.J.
DS DS DS
DS
DS
3 3
3 3
7 78 8
THROUGH-WALL
SCUPPER. TYP.
ROOF DRAIN.
TYP.
TYP. TYP.
12 EXISTING ANTENNA.
WALK-OFF PAD AT
DOWNSPOUT OUTLET. TYP.
EDGE METAL AT PARAPET.
TYP.
A8.32
/4
A8.32
A8.32
A8.32
Sim
A8.32
Sim
A8.32
Sim
A8.32
Sim
A8.31
A8.32
Sim
A8.31
Sim
A8.32
Sim
A8.32
Sim
A8.32
Sim
A8.32
Sim
A8.32
A8.32
Sim
R.D.
R.D.
R.D.
R.D. R.D.
R.D.
R.D. R.D.
R.D.
R.D.
R1
R1
R1
R1
R1
07 54 19.B10PVC WALK-OFF PAD
07 54 19.B10PVC WALK-OFF PAD
MECHANICAL UNIT.
TYP.
2MECHANICAL UNIT.
TYP.
A8.31
INSTALL NEW PVC MEMBRANE. INSTALL NEW FLASHINGS, INCLUDING AT PENETRATIONS AND CURBS.
SEE DETAILS.
INSTALL NEW FLASHING AT EXISTING HVAC UNIT CURBS. REMOVE HVAC EQUIPMENT AS NEEDED TO
REPLACE CURB FLASHING. REPLACE SECTIONS OF DAMAGED CURBS. SEE UNIT PRICES.
INSTALL NEW ROOF DRAINS AND ASSOCIATED FLASHINGS AT EXISTING DRAIN LOCATIONS.
FIELD VERIFY DRAIN DIMENSIONS. NEW ROOF DRAINS TO MATCH EXISTING SIZES. REFER TO DETAILS.
INSTALL NEW PREFABRICATED PVC COATED THROUGH-WALL SCUPPERS AND FLASHING.
FIELD VERIFY SCUPPER DIMENSIONS.
INFILL DECK AND INSULATION (FLUSH) AT ABANDONED ROOF PENETRATIONS. INFILL MATERIAL TO
MATCH EXISTING ADJACENT ROOFING IN THICKNESS AND MATERIAL.
DO NOT DISTURB RATED INTERIOR EXPANSION JOINT MATERIALS. IF EXPANSION JOINT MATERIAL IS
DAMAGED OR MISSING, NOTIFY DESIGN PROFESSIONAL. SEE NEW CONSTRUCTION DETAILS FOR
EXPANSION JOINT DETAILS.
INSTALL NEW FASCIA WITH DRIP EDGE. SEE DETAILS.
FASCIA/DRIP EDGE TO MATCH EXISTING MATERIAL, FINISH, PROFILE AND DIMENSIONS.
INSTALL NEW GUTTERS AND DOWNSPOUTS. GUTTERS/DOWNSPOUTS TO MATCH EXISTING IN
MATERIAL, FINISH, PROFILE AND DIMENSIONS.
INSTALL NEW DOWNSPOUT BOOTS. DOWNSPOUT BOOTS TO TIE INTO EXISTING UNDERGROUND
STORM PIPING. DOWNSPOUT BOOTS TO MATCH EXISTING IN MATERIAL, FINISH AND DIMENSIONS.
INSTALL NEW EDGE METAL FASCIA TRIM AND ASSOCIATED FLASHINGS AT PARAPET CONDITIONS.
INSTALL 2'-0" x 3'-0" MIN. PVC WALK-OFF PADS AT EACH BOTTOM OF EACH DOWNSPOUT AT LOW-
SLOPE ROOF.
EXISTING ANTENNA TO REMAIN.
REPLACE ANY DAMAGED FASCIA AND MAKE WATERTIGHT CONNECTION. INSTALL 2'-0" x 3'-0" PVC
WALK-OFF PAD FULL LENGTH OF DRIP LINE.
517 EAST CONGRESS STREET
SAVANNAH, GEORGIA 31401
tel 912.234.6318 fax 912.236.8414 cogdellmendrala.com
SEAL
SHEET TITLE
PROJECT NO:
DRAWN BY:
DATE:
SCALE:
SHEET
KEY PLAN
Casey Brent Smith
G G
IAA
T
T
S
E
EOF OR
ARC H
IT
R
R
G E
I
E E D
ST
E C T
E
E
C
R T
IF ICAT D ON . 49
STRUCTURAL ENGINEERS
TRUE NORTH PROJECT NORTHSCALE
COPYRIGHT © 2025 COGDELL & MENDRALA ARCHITECTS, PC
OWNER NO:
SAUSSY ENGINEERING
400 JOHNNY MERCER BLVD. SUITE E
SAVANNAH, GA 31410
NOT TO SCALE
GYM
FACILITY NO: 689-0101
As indicated
/2
/2
:3 :4
P
M A u to d e s k D o c s /2
L C
S S
M M
R e ro o f/
L
C S
S M
M R e ro o f_
R V
T
.r v t
A2.02
ROOF PLAN -
ADMIN, KITCHEN,
& MEDIA
JMJ
FEBRUARY 2026
CONSTRUCTION
DOCUMENTS
LCSS MIDWAY
MIDDLE SCHOOL
ROOF
REPLACEMENT
425 EDGEWATER DRIVE
MIDWAY, GA 31320
LIBERTY COUNTY SCHOOL
SYSTEM
MIDWAY MIDDLE SCHOOL
2026-14
KEYNOTE LEGEND - BY SHEET
NO. NOTE
07 54 19.B10 PVC WALK-OFF PAD
GENERAL ROOF PLAN NOTES
1 WHERE A NOTE/DETAIL IS SHOWN FOR ONE CONDITION IT SHALL APPLY TO ALL SIMILAR AND LIKE
CONDITIONS, UNLESS NOTED OTHERWISE.
2 NOT ALL PENETRATIONS ARE SHOWN ON ROOF PLAN. NOTIFY ARCHITECT OF ANY PENETRATIONS
NOT SHOWN ON ROOF PLAN TO COORDINATE FINAL LOCATIONS.
3 WHERE SLOPE (X/X" / 1'-0") IS NOT INDICATED, SLOPE ROOF MIN. 1/4" PER FOOT. PROVIDE SHOP
DRAWINGS INDICATING ACTUAL SLOPES.
4 AT PENETRATIONS IN 07 54 19 POLYVINYLCHLORIDE (PVC) ROOFING , PROVIDE MANUFACTURER'S
STANDARD FLASHING - TO BE INCLUDED IN WARRANTY.
5 INSTALL ALL SHEET METAL FLASHINGS AT ROOF PENETRATIONS IN ACCORDANCE WITH SMACNA
SHEET METAL MANUAL, CURRENT EDITION.
6 ALL ROOF CURBS TO BE INSTALLED BY ROOFING CONTRACTOR.
7 INSTALL CAST IRON BOOTS AT BOTTOM OF ALL DOWNSPOUTS TIED TO UNDERGROUND STORM
PIPING. PAINT TO MATCH DOWNSPOUTS.
8 PROVIDE CRICKETS ON THE HIGH SIDE OF ALL CURBS EXCEEDING 30" IN WIDTH.
9 SLOPE ALL CRICKETS MINIMUM 1/4" PER FOOT, UNLESS NOTED OTHERWISE.
10 INSTALL FLASHING AT ALL ROOF PENETRATIONS.
11 GUTTERS SHALL BE SLOPED TOWARDS DOWNSPOUTS.
12 DOWNSPOUTS TO MATCH EXISTING IN SIZE AND FINISH, UNLESS NOTED OTHERWISE.
13 TOPS OF ROOF CURBS TO BE LEVEL.
14 FIELD VERIFY ALL EXISTING ITEMS THAT ARE TO BE REPLACED, INCLUDING ROOF DRAINS, EXPANSION
JOINT COVERS, PRIOR TO SHOP DRAWINGS/SUBMITTALS.
15 TOPS OF CURBS AND PENETRATIONS TO BE MINIMUM 8" ABOVE ROOF SURFACE. EXTEND CURBS AND
PENETRATIONS TO ACHIEVE 8" MINIMUM.
16 EXISTING ROOF SLOPES TO REMAIN. CONTACT DESIGN PROFESSIONAL IF EXISTING SLOPE IS NOT
CODE COMPLIANT OR IS RESULTING IN PONDING.
17 EXISTING BLOCKING IN GOOD CONDITION MAY REMAIN. DETERIORATED WOOD BLOCKING SHALL BE
REPLACED UNDER UNIT COST.
18 WHERE BLOCKING IS INSTALLED OVER MASONRY, UNDERLAY WITH 30# FELT AND PROVIDE 1/2"
CHEMICAL ANCHORS UNDER UNIT COST.
19 ONCE MEMBRANE IS REMOVED, ROOFING CONTRACTOR TO INVESTIGATE CONDITION OF EXISTING ROOF SYSTEM AND NOTIFY DESIGN PROFESSIONAL IF LWIC AND/OR INSULATION IS DAMAGED OR
MISSING AND REQUIRES REPLACEMENT. (SEE UNIT PRICES AND ALLOWANCES).
20 ALL EQUIPMENT TO REMAIN SHALL BE PROTECTED FROM ROOFING ACTIVITIES.
21 ALL EXPOSED, UNPREFINISHED EXTERIOR METAL SURFACES SHALL BE PAINTED.
22 PROVIDE ROOF PROTECTION PAD AT TOP AND BOTTOM OF ALL ROOF ACCESS LADDERS OR ACCESS
DOORS/HATCHES.
ROOF LEGEND
1/8" = 1'-0"A2.02
ROOF PLAN - ADMIN, KITCHEN, & MEDIA1
ROOF PLAN NOTES
EXHAUST FAN WITH MANUFACTURED CURB
ROOF DRAIN
X"/1'-0" DIRECTION OF ROOF PITCH
DOWNSPOUTDS
VTR
NOT IN CONTRACT
R.D.
WING 200 ADMIN, KITCHEN,
& MEDIA
/4
NOT IN CONTRACT
DSDSDSDSDSDS
DS
DS
DS DS
DS DS DS DS DS DS DS DS DS
7 8 TYP.7 8 TYP.7 8 TYP.
7 8TYP.
7 8 TYP.
7 8 TYP. 7 8 TYP. 7 8 TYP. 7 8 TYP. 7 8 TYP.
/4
WALK-OFF PAD AT
DOWNSPOUT OUTLET.
TYP.
A8.32
Sim
A8.32
Sim
A8.32
Sim
A8.32
A8.32
A8.32
Sim
1/4" / 1'-0"
/4
R1
R1
5 5 5 5
9 9 9 9 9
INSTALL NEW PVC MEMBRANE. INSTALL NEW FLASHINGS, INCLUDING AT PENETRATIONS AND CURBS.
SEE DETAILS.
INSTALL NEW FLASHING AT EXISTING HVAC UNIT CURBS. REMOVE HVAC EQUIPMENT AS NEEDED TO
REPLACE CURB FLASHING. REPLACE SECTIONS OF DAMAGED CURBS. SEE UNIT PRICES.
INSTALL NEW ROOF DRAINS AND ASSOCIATED FLASHINGS AT EXISTING DRAIN LOCATIONS.
FIELD VERIFY DRAIN DIMENSIONS. NEW ROOF DRAINS TO MATCH EXISTING SIZES. REFER TO DETAILS.
INSTALL NEW PREFABRICATED PVC COATED THROUGH-WALL SCUPPERS AND FLASHING.
FIELD VERIFY SCUPPER DIMENSIONS.
INFILL DECK AND INSULATION (FLUSH) AT ABANDONED ROOF PENETRATIONS. INFILL MATERIAL TO
MATCH EXISTING ADJACENT ROOFING IN THICKNESS AND MATERIAL.
DO NOT DISTURB RATED INTERIOR EXPANSION JOINT MATERIALS. IF EXPANSION JOINT MATERIAL IS
DAMAGED OR MISSING, NOTIFY DESIGN PROFESSIONAL. SEE NEW CONSTRUCTION DETAILS FOR
EXPANSION JOINT DETAILS.
INSTALL NEW FASCIA WITH DRIP EDGE. SEE DETAILS.
FASCIA/DRIP EDGE TO MATCH EXISTING MATERIAL, FINISH, PROFILE AND DIMENSIONS.
INSTALL NEW GUTTERS AND DOWNSPOUTS. GUTTERS/DOWNSPOUTS TO MATCH EXISTING IN
MATERIAL, FINISH, PROFILE AND DIMENSIONS.
INSTALL NEW DOWNSPOUT BOOTS. DOWNSPOUT BOOTS TO TIE INTO EXISTING UNDERGROUND
STORM PIPING. DOWNSPOUT BOOTS TO MATCH EXISTING IN MATERIAL, FINISH AND DIMENSIONS.
INSTALL NEW EDGE METAL FASCIA TRIM AND ASSOCIATED FLASHINGS AT PARAPET CONDITIONS.
INSTALL 2'-0" x 3'-0" MIN. PVC WALK-OFF PADS AT EACH BOTTOM OF EACH DOWNSPOUT AT LOW-
SLOPE ROOF.
EXISTING ANTENNA TO REMAIN.
REPLACE ANY DAMAGED FASCIA AND MAKE WATERTIGHT CONNECTION. INSTALL 2'-0" x 3'-0" PVC
WALK-OFF PAD FULL LENGTH OF DRIP LINE.
517 EAST CONGRESS STREET
SAVANNAH, GEORGIA 31401
tel 912.234.6318 fax 912.236.8414 cogdellmendrala.com
SEAL
SHEET TITLE
PROJECT NO:
DRAWN BY:
DATE:
SCALE:
SHEET
KEY PLAN
Casey Brent Smith
G G
IAA
T
T
S
E
EOF OR
ARC H
IT
R
R
G E
I
E E D
ST
E C T
E
E
C
R T
IF ICAT D ON . 49
STRUCTURAL ENGINEERS
TRUE NORTH PROJECT NORTHSCALE
COPYRIGHT © 2025 COGDELL & MENDRALA ARCHITECTS, PC
OWNER NO:
SAUSSY ENGINEERING
400 JOHNNY MERCER BLVD. SUITE E
SAVANNAH, GA 31410
NOT TO SCALE
GYM
FACILITY NO: 689-0101
As indicated
/2
/2
:3 :4
P
M A u to d e s k D o c s /2
L C
S S
M M
R e ro o f/
L
C S
S M
M R e ro o f_
R V
T
.r v t
A2.03
ROOF PLAN -
CLASSROOM
WING 200
JMJ
FEBRUARY 2026
CONSTRUCTION
DOCUMENTS
LCSS MIDWAY
MIDDLE SCHOOL
ROOF
REPLACEMENT
425 EDGEWATER DRIVE
MIDWAY, GA 31320
LIBERTY COUNTY SCHOOL
SYSTEM
MIDWAY MIDDLE SCHOOL
2026-14
KEYNOTE LEGEND - BY SHEET
NO. NOTE
GENERAL ROOF PLAN NOTES
1 WHERE A NOTE/DETAIL IS SHOWN FOR ONE CONDITION IT SHALL APPLY TO ALL SIMILAR AND LIKE
CONDITIONS, UNLESS NOTED OTHERWISE.
2 NOT ALL PENETRATIONS ARE SHOWN ON ROOF PLAN. NOTIFY ARCHITECT OF ANY PENETRATIONS
NOT SHOWN ON ROOF PLAN TO COORDINATE FINAL LOCATIONS.
3 WHERE SLOPE (X/X" / 1'-0") IS NOT INDICATED, SLOPE ROOF MIN. 1/4" PER FOOT. PROVIDE SHOP
DRAWINGS INDICATING ACTUAL SLOPES.
4 AT PENETRATIONS IN 07 54 19 POLYVINYLCHLORIDE (PVC) ROOFING , PROVIDE MANUFACTURER'S
STANDARD FLASHING - TO BE INCLUDED IN WARRANTY.
5 INSTALL ALL SHEET METAL FLASHINGS AT ROOF PENETRATIONS IN ACCORDANCE WITH SMACNA
SHEET METAL MANUAL, CURRENT EDITION.
6 ALL ROOF CURBS TO BE INSTALLED BY ROOFING CONTRACTOR.
7 INSTALL CAST IRON BOOTS AT BOTTOM OF ALL DOWNSPOUTS TIED TO UNDERGROUND STORM
PIPING. PAINT TO MATCH DOWNSPOUTS.
8 PROVIDE CRICKETS ON THE HIGH SIDE OF ALL CURBS EXCEEDING 30" IN WIDTH.
9 SLOPE ALL CRICKETS MINIMUM 1/4" PER FOOT, UNLESS NOTED OTHERWISE.
10 INSTALL FLASHING AT ALL ROOF PENETRATIONS.
11 GUTTERS SHALL BE SLOPED TOWARDS DOWNSPOUTS.
12 DOWNSPOUTS TO MATCH EXISTING IN SIZE AND FINISH, UNLESS NOTED OTHERWISE.
13 TOPS OF ROOF CURBS TO BE LEVEL.
14 FIELD VERIFY ALL EXISTING ITEMS THAT ARE TO BE REPLACED, INCLUDING ROOF DRAINS, EXPANSION
JOINT COVERS, PRIOR TO SHOP DRAWINGS/SUBMITTALS.
15 TOPS OF CURBS AND PENETRATIONS TO BE MINIMUM 8" ABOVE ROOF SURFACE. EXTEND CURBS AND
PENETRATIONS TO ACHIEVE 8" MINIMUM.
16 EXISTING ROOF SLOPES TO REMAIN. CONTACT DESIGN PROFESSIONAL IF EXISTING SLOPE IS NOT
CODE COMPLIANT OR IS RESULTING IN PONDING.
17 EXISTING BLOCKING IN GOOD CONDITION MAY REMAIN. DETERIORATED WOOD BLOCKING SHALL BE
REPLACED UNDER UNIT COST.
18 WHERE BLOCKING IS INSTALLED OVER MASONRY, UNDERLAY WITH 30# FELT AND PROVIDE 1/2"
CHEMICAL ANCHORS UNDER UNIT COST.
19 ONCE MEMBRANE IS REMOVED, ROOFING CONTRACTOR TO INVESTIGATE CONDITION OF EXISTING ROOF SYSTEM AND NOTIFY DESIGN PROFESSIONAL IF LWIC AND/OR INSULATION IS DAMAGED OR
MISSING AND REQUIRES REPLACEMENT. (SEE UNIT PRICES AND ALLOWANCES).
20 ALL EQUIPMENT TO REMAIN SHALL BE PROTECTED FROM ROOFING ACTIVITIES.
21 ALL EXPOSED, UNPREFINISHED EXTERIOR METAL SURFACES SHALL BE PAINTED.
22 PROVIDE ROOF PROTECTION PAD AT TOP AND BOTTOM OF ALL ROOF ACCESS LADDERS OR ACCESS
DOORS/HATCHES.
ROOF LEGEND
1/8" = 1'-0"A2.03
ROOF PLAN - CLASSROOM WING 2001
ROOF PLAN NOTES
TRUE NORTH PROJECT NORTH
EXHAUST FAN WITH MANUFACTURED CURB
ROOF DRAIN
X"/1'-0" DIRECTION OF ROOF PITCH
DOWNSPOUTDS
VTR
NOT IN CONTRACT
R.D.
WING 300
ADMIN, KITCHEN,
& MEDIA
/4
/4
1" E.J.
DSDSDSDSDSDSDSDSDSDS
DS
DS
DS DS DS DS DS DS DS DS
DS
DS
7 8 TYP.7 8 TYP.7 8 TYP.7 8 TYP.7 8 TYP.
7 8TYP.
7 8 TYP. 7 8 TYP. 7 8 TYP. 7 8 TYP.
7 8TYP.
1/4" / 1'-0"
A8.32
A8.32
Sim
A8.32
Sim
A8.31
Sim
R1
R1
5 5
999999
9 9 9 9
INSTALL NEW PVC MEMBRANE. INSTALL NEW FLASHINGS, INCLUDING AT PENETRATIONS AND CURBS.
SEE DETAILS.
INSTALL NEW FLASHING AT EXISTING HVAC UNIT CURBS. REMOVE HVAC EQUIPMENT AS NEEDED TO
REPLACE CURB FLASHING. REPLACE SECTIONS OF DAMAGED CURBS. SEE UNIT PRICES.
INSTALL NEW ROOF DRAINS AND ASSOCIATED FLASHINGS AT EXISTING DRAIN LOCATIONS.
FIELD VERIFY DRAIN DIMENSIONS. NEW ROOF DRAINS TO MATCH EXISTING SIZES. REFER TO DETAILS.
INSTALL NEW PREFABRICATED PVC COATED THROUGH-WALL SCUPPERS AND FLASHING.
FIELD VERIFY SCUPPER DIMENSIONS.
INFILL DECK AND INSULATION (FLUSH) AT ABANDONED ROOF PENETRATIONS. INFILL MATERIAL TO
MATCH EXISTING ADJACENT ROOFING IN THICKNESS AND MATERIAL.
DO NOT DISTURB RATED INTERIOR EXPANSION JOINT MATERIALS. IF EXPANSION JOINT MATERIAL IS
DAMAGED OR MISSING, NOTIFY DESIGN PROFESSIONAL. SEE NEW CONSTRUCTION DETAILS FOR
EXPANSION JOINT DETAILS.
INSTALL NEW FASCIA WITH DRIP EDGE. SEE DETAILS.
FASCIA/DRIP EDGE TO MATCH EXISTING MATERIAL, FINISH, PROFILE AND DIMENSIONS.
INSTALL NEW GUTTERS AND DOWNSPOUTS. GUTTERS/DOWNSPOUTS TO MATCH EXISTING IN
MATERIAL, FINISH, PROFILE AND DIMENSIONS.
INSTALL NEW DOWNSPOUT BOOTS. DOWNSPOUT BOOTS TO TIE INTO EXISTING UNDERGROUND
STORM PIPING. DOWNSPOUT BOOTS TO MATCH EXISTING IN MATERIAL, FINISH AND DIMENSIONS.
INSTALL NEW EDGE METAL FASCIA TRIM AND ASSOCIATED FLASHINGS AT PARAPET CONDITIONS.
INSTALL 2'-0" x 3'-0" MIN. PVC WALK-OFF PADS AT EACH BOTTOM OF EACH DOWNSPOUT AT LOW-
SLOPE ROOF.
EXISTING ANTENNA TO REMAIN.
REPLACE ANY DAMAGED FASCIA AND MAKE WATERTIGHT CONNECTION. INSTALL 2'-0" x 3'-0" PVC
WALK-OFF PAD FULL LENGTH OF DRIP LINE.
517 EAST CONGRESS STREET
SAVANNAH, GEORGIA 31401
tel 912.234.6318 fax 912.236.8414 cogdellmendrala.com
SEAL
SHEET TITLE
PROJECT NO:
DRAWN BY:
DATE:
SCALE:
SHEET
KEY PLAN
Casey Brent Smith
G G
IAA
T
T
S
E
EOF OR
ARC H
IT
R
R
G E
I
E E D
ST
E C T
E
E
C
R T
IF ICAT D ON . 49
STRUCTURAL ENGINEERS
TRUE NORTH PROJECT NORTHSCALE
COPYRIGHT © 2025 COGDELL & MENDRALA ARCHITECTS, PC
OWNER NO:
SAUSSY ENGINEERING
400 JOHNNY MERCER BLVD. SUITE E
SAVANNAH, GA 31410
NOT TO SCALE
GYM
FACILITY NO: 689-0101
As indicated
/2
/2
:3 :4
P
M A u to d e s k D o c s /2
L C
S S
M M
R e ro o f/
L
C S
S M
M R e ro o f_
R V
T
.r v t
A2.04
ROOF PLAN -
CLASSROOM
WING 300
JMJ
FEBRUARY 2026
CONSTRUCTION
DOCUMENTS
LCSS MIDWAY
MIDDLE SCHOOL
ROOF
REPLACEMENT
425 EDGEWATER DRIVE
MIDWAY, GA 31320
LIBERTY COUNTY SCHOOL
SYSTEM
MIDWAY MIDDLE SCHOOL
2026-14
KEYNOTE LEGEND - BY SHEET
NO. NOTE
GENERAL ROOF PLAN NOTES
1 WHERE A NOTE/DETAIL IS SHOWN FOR ONE CONDITION IT SHALL APPLY TO ALL SIMILAR AND LIKE
CONDITIONS, UNLESS NOTED OTHERWISE.
2 NOT ALL PENETRATIONS ARE SHOWN ON ROOF PLAN. NOTIFY ARCHITECT OF ANY PENETRATIONS
NOT SHOWN ON ROOF PLAN TO COORDINATE FINAL LOCATIONS.
3 WHERE SLOPE (X/X" / 1'-0") IS NOT INDICATED, SLOPE ROOF MIN. 1/4" PER FOOT. PROVIDE SHOP
DRAWINGS INDICATING ACTUAL SLOPES.
4 AT PENETRATIONS IN 07 54 19 POLYVINYLCHLORIDE (PVC) ROOFING , PROVIDE MANUFACTURER'S
STANDARD FLASHING - TO BE INCLUDED IN WARRANTY.
5 INSTALL ALL SHEET METAL FLASHINGS AT ROOF PENETRATIONS IN ACCORDANCE WITH SMACNA
SHEET METAL MANUAL, CURRENT EDITION.
6 ALL ROOF CURBS TO BE INSTALLED BY ROOFING CONTRACTOR.
7 INSTALL CAST IRON BOOTS AT BOTTOM OF ALL DOWNSPOUTS TIED TO UNDERGROUND STORM
PIPING. PAINT TO MATCH DOWNSPOUTS.
8 PROVIDE CRICKETS ON THE HIGH SIDE OF ALL CURBS EXCEEDING 30" IN WIDTH.
9 SLOPE ALL CRICKETS MINIMUM 1/4" PER FOOT, UNLESS NOTED OTHERWISE.
10 INSTALL FLASHING AT ALL ROOF PENETRATIONS.
11 GUTTERS SHALL BE SLOPED TOWARDS DOWNSPOUTS.
12 DOWNSPOUTS TO MATCH EXISTING IN SIZE AND FINISH, UNLESS NOTED OTHERWISE.
13 TOPS OF ROOF CURBS TO BE LEVEL.
14 FIELD VERIFY ALL EXISTING ITEMS THAT ARE TO BE REPLACED, INCLUDING ROOF DRAINS, EXPANSION
JOINT COVERS, PRIOR TO SHOP DRAWINGS/SUBMITTALS.
15 TOPS OF CURBS AND PENETRATIONS TO BE MINIMUM 8" ABOVE ROOF SURFACE. EXTEND CURBS AND
PENETRATIONS TO ACHIEVE 8" MINIMUM.
16 EXISTING ROOF SLOPES TO REMAIN. CONTACT DESIGN PROFESSIONAL IF EXISTING SLOPE IS NOT
CODE COMPLIANT OR IS RESULTING IN PONDING.
17 EXISTING BLOCKING IN GOOD CONDITION MAY REMAIN. DETERIORATED WOOD BLOCKING SHALL BE
REPLACED UNDER UNIT COST.
18 WHERE BLOCKING IS INSTALLED OVER MASONRY, UNDERLAY WITH 30# FELT AND PROVIDE 1/2"
CHEMICAL ANCHORS UNDER UNIT COST.
19 ONCE MEMBRANE IS REMOVED, ROOFING CONTRACTOR TO INVESTIGATE CONDITION OF EXISTING ROOF SYSTEM AND NOTIFY DESIGN PROFESSIONAL IF LWIC AND/OR INSULATION IS DAMAGED OR
MISSING AND REQUIRES REPLACEMENT. (SEE UNIT PRICES AND ALLOWANCES).
20 ALL EQUIPMENT TO REMAIN SHALL BE PROTECTED FROM ROOFING ACTIVITIES.
21 ALL EXPOSED, UNPREFINISHED EXTERIOR METAL SURFACES SHALL BE PAINTED.
22 PROVIDE ROOF PROTECTION PAD AT TOP AND BOTTOM OF ALL ROOF ACCESS LADDERS OR ACCESS
DOORS/HATCHES.
ROOF LEGEND
1/8" = 1'-0"A2.04
ROOF PLAN - CLASSROOM WING 3001
ROOF PLAN NOTES
TRUE NORTH PROJECT NORTH
EXHAUST FAN WITH MANUFACTURED CURB
ROOF DRAIN
X"/1'-0" DIRECTION OF ROOF PITCH
DOWNSPOUTDS
VTR
NOT IN CONTRACT
R.D.
WING 400 ADMIN, KITCHEN,
& MEDIA
/4
/4
1" E.J.
DS
DSDSDSDSDSDSDSDS
DS
DS
DS DS DS DS DS DS DS DS DS
7 8TYP.7 8 TYP.7 8 TYP.7 8 TYP.
7 8TYP.
7 8 TYP. 7 8 TYP. 7 8 TYP. 7 8 TYP. 7 8 TYP.
1/4" / 1'-0"
A8.32
Sim
A8.32
Sim
A8.32
Sim
A8.31
Sim
R1
R1
9 9 9 9 9
INSTALL NEW PVC MEMBRANE. INSTALL NEW FLASHINGS, INCLUDING AT PENETRATIONS AND CURBS.
SEE DETAILS.
INSTALL NEW FLASHING AT EXISTING HVAC UNIT CURBS. REMOVE HVAC EQUIPMENT AS NEEDED TO
REPLACE CURB FLASHING. REPLACE SECTIONS OF DAMAGED CURBS. SEE UNIT PRICES.
INSTALL NEW ROOF DRAINS AND ASSOCIATED FLASHINGS AT EXISTING DRAIN LOCATIONS.
FIELD VERIFY DRAIN DIMENSIONS. NEW ROOF DRAINS TO MATCH EXISTING SIZES. REFER TO DETAILS.
INSTALL NEW PREFABRICATED PVC COATED THROUGH-WALL SCUPPERS AND FLASHING.
FIELD VERIFY SCUPPER DIMENSIONS.
INFILL DECK AND INSULATION (FLUSH) AT ABANDONED ROOF PENETRATIONS. INFILL MATERIAL TO
MATCH EXISTING ADJACENT ROOFING IN THICKNESS AND MATERIAL.
DO NOT DISTURB RATED INTERIOR EXPANSION JOINT MATERIALS. IF EXPANSION JOINT MATERIAL IS
DAMAGED OR MISSING, NOTIFY DESIGN PROFESSIONAL. SEE NEW CONSTRUCTION DETAILS FOR
EXPANSION JOINT DETAILS.
INSTALL NEW FASCIA WITH DRIP EDGE. SEE DETAILS.
FASCIA/DRIP EDGE TO MATCH EXISTING MATERIAL, FINISH, PROFILE AND DIMENSIONS.
INSTALL NEW GUTTERS AND DOWNSPOUTS. GUTTERS/DOWNSPOUTS TO MATCH EXISTING IN
MATERIAL, FINISH, PROFILE AND DIMENSIONS.
INSTALL NEW DOWNSPOUT BOOTS. DOWNSPOUT BOOTS TO TIE INTO EXISTING UNDERGROUND
STORM PIPING. DOWNSPOUT BOOTS TO MATCH EXISTING IN MATERIAL, FINISH AND DIMENSIONS.
INSTALL NEW EDGE METAL FASCIA TRIM AND ASSOCIATED FLASHINGS AT PARAPET CONDITIONS.
INSTALL 2'-0" x 3'-0" MIN. PVC WALK-OFF PADS AT EACH BOTTOM OF EACH DOWNSPOUT AT LOW-
SLOPE ROOF.
EXISTING ANTENNA TO REMAIN.
REPLACE ANY DAMAGED FASCIA AND MAKE WATERTIGHT CONNECTION. INSTALL 2'-0" x 3'-0" PVC
WALK-OFF PAD FULL LENGTH OF DRIP LINE.
517 EAST CONGRESS STREET
SAVANNAH, GEORGIA 31401
tel 912.234.6318 fax 912.236.8414 cogdellmendrala.com
SEAL
SHEET TITLE
PROJECT NO:
DRAWN BY:
DATE:
SCALE:
SHEET
KEY PLAN
Casey Brent Smith
G G
IAA
T
T
S
E
EOF OR
ARC H
IT
R
R
G E
I
E E D
ST
E C T
E
E
C
R T
IF ICAT D ON . 49
STRUCTURAL ENGINEERS
TRUE NORTH PROJECT NORTHSCALE
COPYRIGHT © 2025 COGDELL & MENDRALA ARCHITECTS, PC
OWNER NO:
SAUSSY ENGINEERING
400 JOHNNY MERCER BLVD. SUITE E
SAVANNAH, GA 31410
NOT TO SCALE
GYM
FACILITY NO: 689-0101
As indicated
/2
/2
:3 :4
P
M A u to d e s k D o c s /2
L C
S S
M M
R e ro o f/
L
C S
S M
M R e ro o f_
R V
T
.r v t
A2.05
ROOF PLAN -
CLASSROOM
WING 400
JMJ
FEBRUARY 2026
CONSTRUCTION
DOCUMENTS
LCSS MIDWAY
MIDDLE SCHOOL
ROOF
REPLACEMENT
425 EDGEWATER DRIVE
MIDWAY, GA 31320
LIBERTY COUNTY SCHOOL
SYSTEM
MIDWAY MIDDLE SCHOOL
2026-14
KEYNOTE LEGEND - BY SHEET
NO. NOTE
GENERAL ROOF PLAN NOTES
1 WHERE A NOTE/DETAIL IS SHOWN FOR ONE CONDITION IT SHALL APPLY TO ALL SIMILAR AND LIKE
CONDITIONS, UNLESS NOTED OTHERWISE.
2 NOT ALL PENETRATIONS ARE SHOWN ON ROOF PLAN. NOTIFY ARCHITECT OF ANY PENETRATIONS
NOT SHOWN ON ROOF PLAN TO COORDINATE FINAL LOCATIONS.
3 WHERE SLOPE (X/X" / 1'-0") IS NOT INDICATED, SLOPE ROOF MIN. 1/4" PER FOOT. PROVIDE SHOP
DRAWINGS INDICATING ACTUAL SLOPES.
4 AT PENETRATIONS IN 07 54 19 POLYVINYLCHLORIDE (PVC) ROOFING , PROVIDE MANUFACTURER'S
STANDARD FLASHING - TO BE INCLUDED IN WARRANTY.
5 INSTALL ALL SHEET METAL FLASHINGS AT ROOF PENETRATIONS IN ACCORDANCE WITH SMACNA
SHEET METAL MANUAL, CURRENT EDITION.
6 ALL ROOF CURBS TO BE INSTALLED BY ROOFING CONTRACTOR.
7 INSTALL CAST IRON BOOTS AT BOTTOM OF ALL DOWNSPOUTS TIED TO UNDERGROUND STORM
PIPING. PAINT TO MATCH DOWNSPOUTS.
8 PROVIDE CRICKETS ON THE HIGH SIDE OF ALL CURBS EXCEEDING 30" IN WIDTH.
9 SLOPE ALL CRICKETS MINIMUM 1/4" PER FOOT, UNLESS NOTED OTHERWISE.
10 INSTALL FLASHING AT ALL ROOF PENETRATIONS.
11 GUTTERS SHALL BE SLOPED TOWARDS DOWNSPOUTS.
12 DOWNSPOUTS TO MATCH EXISTING IN SIZE AND FINISH, UNLESS NOTED OTHERWISE.
13 TOPS OF ROOF CURBS TO BE LEVEL.
14 FIELD VERIFY ALL EXISTING ITEMS THAT ARE TO BE REPLACED, INCLUDING ROOF DRAINS, EXPANSION
JOINT COVERS, PRIOR TO SHOP DRAWINGS/SUBMITTALS.
15 TOPS OF CURBS AND PENETRATIONS TO BE MINIMUM 8" ABOVE ROOF SURFACE. EXTEND CURBS AND
PENETRATIONS TO ACHIEVE 8" MINIMUM.
16 EXISTING ROOF SLOPES TO REMAIN. CONTACT DESIGN PROFESSIONAL IF EXISTING SLOPE IS NOT
CODE COMPLIANT OR IS RESULTING IN PONDING.
17 EXISTING BLOCKING IN GOOD CONDITION MAY REMAIN. DETERIORATED WOOD BLOCKING SHALL BE
REPLACED UNDER UNIT COST.
18 WHERE BLOCKING IS INSTALLED OVER MASONRY, UNDERLAY WITH 30# FELT AND PROVIDE 1/2"
CHEMICAL ANCHORS UNDER UNIT COST.
19 ONCE MEMBRANE IS REMOVED, ROOFING CONTRACTOR TO INVESTIGATE CONDITION OF EXISTING ROOF SYSTEM AND NOTIFY DESIGN PROFESSIONAL IF LWIC AND/OR INSULATION IS DAMAGED OR
MISSING AND REQUIRES REPLACEMENT. (SEE UNIT PRICES AND ALLOWANCES).
20 ALL EQUIPMENT TO REMAIN SHALL BE PROTECTED FROM ROOFING ACTIVITIES.
21 ALL EXPOSED, UNPREFINISHED EXTERIOR METAL SURFACES SHALL BE PAINTED.
22 PROVIDE ROOF PROTECTION PAD AT TOP AND BOTTOM OF ALL ROOF ACCESS LADDERS OR ACCESS
DOORS/HATCHES.
ROOF LEGEND
1/8" = 1'-0"A2.05
ROOF PLAN - CLASSROOM WING 4001
ROOF PLAN NOTES
TRUE NORTH PROJECT NORTH
EXHAUST FAN WITH MANUFACTURED CURB
ROOF DRAIN
X"/1'-0" DIRECTION OF ROOF PITCH
DOWNSPOUTDS
VTR
NOT IN CONTRACT
R.D.
WING 500 ADMIN, KITCHEN,
& MEDIA
/4
NOT IN
CONTRACT
1" E.J.
DSDSDSDSDSDSDSDSDSDS
DS
DS
DS DS DS DS DS DS DS DS DS
7 8 TYP.7 8 TYP.7 8 TYP.7 8 TYP.7 8 TYP.
7 8TYP.
7 8 TYP. 7 8 TYP. 7 8 TYP. 7 8 TYP.
/4
1/4" / 1'-0"
A8.32
Sim
A8.32
Sim
A8.32
Sim
A8.31
Sim
R1
R1
99999
9 9 9 9
INSTALL NEW PVC MEMBRANE. INSTALL NEW FLASHINGS, INCLUDING AT PENETRATIONS AND CURBS.
SEE DETAILS.
INSTALL NEW FLASHING AT EXISTING HVAC UNIT CURBS. REMOVE HVAC EQUIPMENT AS NEEDED TO
REPLACE CURB FLASHING. REPLACE SECTIONS OF DAMAGED CURBS. SEE UNIT PRICES.
INSTALL NEW ROOF DRAINS AND ASSOCIATED FLASHINGS AT EXISTING DRAIN LOCATIONS.
FIELD VERIFY DRAIN DIMENSIONS. NEW ROOF DRAINS TO MATCH EXISTING SIZES. REFER TO DETAILS.
INSTALL NEW PREFABRICATED PVC COATED THROUGH-WALL SCUPPERS AND FLASHING.
FIELD VERIFY SCUPPER DIMENSIONS.
INFILL DECK AND INSULATION (FLUSH) AT ABANDONED ROOF PENETRATIONS. INFILL MATERIAL TO
MATCH EXISTING ADJACENT ROOFING IN THICKNESS AND MATERIAL.
DO NOT DISTURB RATED INTERIOR EXPANSION JOINT MATERIALS. IF EXPANSION JOINT MATERIAL IS
DAMAGED OR MISSING, NOTIFY DESIGN PROFESSIONAL. SEE NEW CONSTRUCTION DETAILS FOR
EXPANSION JOINT DETAILS.
INSTALL NEW FASCIA WITH DRIP EDGE. SEE DETAILS.
FASCIA/DRIP EDGE TO MATCH EXISTING MATERIAL, FINISH, PROFILE AND DIMENSIONS.
INSTALL NEW GUTTERS AND DOWNSPOUTS. GUTTERS/DOWNSPOUTS TO MATCH EXISTING IN
MATERIAL, FINISH, PROFILE AND DIMENSIONS.
INSTALL NEW DOWNSPOUT BOOTS. DOWNSPOUT BOOTS TO TIE INTO EXISTING UNDERGROUND
STORM PIPING. DOWNSPOUT BOOTS TO MATCH EXISTING IN MATERIAL, FINISH AND DIMENSIONS.
INSTALL NEW EDGE METAL FASCIA TRIM AND ASSOCIATED FLASHINGS AT PARAPET CONDITIONS.
INSTALL 2'-0" x 3'-0" MIN. PVC WALK-OFF PADS AT EACH BOTTOM OF EACH DOWNSPOUT AT LOW-
SLOPE ROOF.
EXISTING ANTENNA TO REMAIN.
REPLACE ANY DAMAGED FASCIA AND MAKE WATERTIGHT CONNECTION. INSTALL 2'-0" x 3'-0" PVC
WALK-OFF PAD FULL LENGTH OF DRIP LINE.
517 EAST CONGRESS STREET
SAVANNAH, GEORGIA 31401
tel 912.234.6318 fax 912.236.8414 cogdellmendrala.com
SEAL
SHEET TITLE
PROJECT NO:
DRAWN BY:
DATE:
SCALE:
SHEET
KEY PLAN
Casey Brent Smith
G G
IAA
T
T
S
E
EOF OR
ARC H
IT
R
R
G E
I
E E D
ST
E C T
E
E
C
R T
IF ICAT D ON . 49
STRUCTURAL ENGINEERS
TRUE NORTH PROJECT NORTHSCALE
COPYRIGHT © 2025 COGDELL & MENDRALA ARCHITECTS, PC
OWNER NO:
SAUSSY ENGINEERING
400 JOHNNY MERCER BLVD. SUITE E
SAVANNAH, GA 31410
NOT TO SCALE
GYM
FACILITY NO: 689-0101
As indicated
/2
/2
:3 :4
P
M A u to d e s k D o c s /2
L C
S S
M M
R e ro o f/
L
C S
S M
M R e ro o f_
R V
T
.r v t
A2.06
ROOF PLAN -
CLASSROOM
WING 500
JMJ
FEBRUARY 2026
CONSTRUCTION
DOCUMENTS
LCSS MIDWAY
MIDDLE SCHOOL
ROOF
REPLACEMENT
425 EDGEWATER DRIVE
MIDWAY, GA 31320
LIBERTY COUNTY SCHOOL
SYSTEM
MIDWAY MIDDLE SCHOOL
2026-14
KEYNOTE LEGEND - BY SHEET
NO. NOTE
GENERAL ROOF PLAN NOTES
1 WHERE A NOTE/DETAIL IS SHOWN FOR ONE CONDITION IT SHALL APPLY TO ALL SIMILAR AND LIKE
CONDITIONS, UNLESS NOTED OTHERWISE.
2 NOT ALL PENETRATIONS ARE SHOWN ON ROOF PLAN. NOTIFY ARCHITECT OF ANY PENETRATIONS
NOT SHOWN ON ROOF PLAN TO COORDINATE FINAL LOCATIONS.
3 WHERE SLOPE (X/X" / 1'-0") IS NOT INDICATED, SLOPE ROOF MIN. 1/4" PER FOOT. PROVIDE SHOP
DRAWINGS INDICATING ACTUAL SLOPES.
4 AT PENETRATIONS IN 07 54 19 POLYVINYLCHLORIDE (PVC) ROOFING , PROVIDE MANUFACTURER'S
STANDARD FLASHING - TO BE INCLUDED IN WARRANTY.
5 INSTALL ALL SHEET METAL FLASHINGS AT ROOF PENETRATIONS IN ACCORDANCE WITH SMACNA
SHEET METAL MANUAL, CURRENT EDITION.
6 ALL ROOF CURBS TO BE INSTALLED BY ROOFING CONTRACTOR.
7 INSTALL CAST IRON BOOTS AT BOTTOM OF ALL DOWNSPOUTS TIED TO UNDERGROUND STORM
PIPING. PAINT TO MATCH DOWNSPOUTS.
8 PROVIDE CRICKETS ON THE HIGH SIDE OF ALL CURBS EXCEEDING 30" IN WIDTH.
9 SLOPE ALL CRICKETS MINIMUM 1/4" PER FOOT, UNLESS NOTED OTHERWISE.
10 INSTALL FLASHING AT ALL ROOF PENETRATIONS.
11 GUTTERS SHALL BE SLOPED TOWARDS DOWNSPOUTS.
12 DOWNSPOUTS TO MATCH EXISTING IN SIZE AND FINISH, UNLESS NOTED OTHERWISE.
13 TOPS OF ROOF CURBS TO BE LEVEL.
14 FIELD VERIFY ALL EXISTING ITEMS THAT ARE TO BE REPLACED, INCLUDING ROOF DRAINS, EXPANSION
JOINT COVERS, PRIOR TO SHOP DRAWINGS/SUBMITTALS.
15 TOPS OF CURBS AND PENETRATIONS TO BE MINIMUM 8" ABOVE ROOF SURFACE. EXTEND CURBS AND
PENETRATIONS TO ACHIEVE 8" MINIMUM.
16 EXISTING ROOF SLOPES TO REMAIN. CONTACT DESIGN PROFESSIONAL IF EXISTING SLOPE IS NOT
CODE COMPLIANT OR IS RESULTING IN PONDING.
17 EXISTING BLOCKING IN GOOD CONDITION MAY REMAIN. DETERIORATED WOOD BLOCKING SHALL BE
REPLACED UNDER UNIT COST.
18 WHERE BLOCKING IS INSTALLED OVER MASONRY, UNDERLAY WITH 30# FELT AND PROVIDE 1/2"
CHEMICAL ANCHORS UNDER UNIT COST.
19 ONCE MEMBRANE IS REMOVED, ROOFING CONTRACTOR TO INVESTIGATE CONDITION OF EXISTING ROOF SYSTEM AND NOTIFY DESIGN PROFESSIONAL IF LWIC AND/OR INSULATION IS DAMAGED OR
MISSING AND REQUIRES REPLACEMENT. (SEE UNIT PRICES AND ALLOWANCES).
20 ALL EQUIPMENT TO REMAIN SHALL BE PROTECTED FROM ROOFING ACTIVITIES.
21 ALL EXPOSED, UNPREFINISHED EXTERIOR METAL SURFACES SHALL BE PAINTED.
22 PROVIDE ROOF PROTECTION PAD AT TOP AND BOTTOM OF ALL ROOF ACCESS LADDERS OR ACCESS
DOORS/HATCHES.
ROOF LEGEND
1/8" = 1'-0"A2.06
ROOF PLAN - CLASSROOM WING 5001
ROOF PLAN NOTES
NOTES:
1. EXISTING ROOF DRAIN SIZES VARY.
EXISTING DRAIN BODY
RAIN WATER LEADER - FIELD VERIFY DIAMETER
MECHANICAL WATERTIGHT CONNECTION SEAL
EXISTING DRAIN BOWL
PVC COATED ALUMINUM FLANGE
ROOFING MANUF'S RECOMMENDED SEALANT
07 54 19.A7 MANUFACTURED RETROFIT DRAIN
07 54 19.B2 FLASHING MEMBRANE
07 54 19 POLYVINYL CHLORIDE ROOFING
EXISTING STEEL DECK
EXISTING WOOD BLOCKING.
SEE GENERAL NOTE 17, SHEET A2.01
RETROFIT DRAIN RETAINING CLIPS
AT PERIMETER OF
SCUPPER OPENING.
FASTEN USING GALVANIZED ANNULAR
RING NAILS AT 4" O.C. STAGGERED.
ADHERED.
07 54 19 POLYVINYL CHLORIDE ROOFING
07 54 19.B2 FLASHING MEMBRANE
07 54 19.D22
PREFABRICATED PVC CLAD METAL
SCUPPER
07 54 19.B2 FLASHING MEMBRANE
07 54 19.B2 FLASHING MEMBRANE
07 92 00.A1SEALANT
EXISTING STRUCTURAL DECK
EXISTING RIGID INSULATION
EXISTING WOOD BLOCKING
EXIST. PLUMB. VENT
(NOTE - IF VENT TERMINATES LESS
THAN 8" ABOVE MEMBRANE, EXTEND
PIPE TO TERMINATE ABOVE 8")
07 54 19
POLYVINYL
CHLORIDE ROOFING
07 54 19.I
PREFABRICATED
STACK/PIPE BOOT
AND CLAMP
EXISTING DECK
EXISTING INSULATION SYSTEM
8" M
IN
M
IN
1"
07 54 19.B5 BASE FLASH
07 92 00.A1 SEALANT
8" M
IN
EXISTING HOT STACK
07 92 00.A1 SEALANT
(HIGH TEMPERATURE)
RAIN COLLAR
07 54 19.B2 FLASHING MEMBRANE
07 54 19.B5 BASE FLASH
07 54 19
POLYVINYL
CHLORIDE ROOFING
STAINLESS STEEL HOSE CLAMP
METAL…