250924 LPS STEVENSON HYDRATION STATIONS ADDENDUM 01 DRAWINGS (25-040).pdf
PDF 2 MB Posted
- Attached to
- 2022 Bond- Asbestos Abatement for BP10
- Solicitation number
- RFP-WCS-250000003095-1
- Issued by
- Macomb County, Westland City, Michigan
About this file
This document is a set of architectural and engineering plans for the Livonia Public Schools Hydration Stations project at Stevenson High School in Livonia, Michigan, dated September 24, 2025. The project involves installing new drinking fountains and bottle filling stations at various locations throughout the school, with work to be performed across multiple building units and floors. The plans include detailed demolition of existing drinking fountains, electrical and plumbing modifications, and installation of new Elkay electric water coolers with bottle filling capabilities. The project number is 2025-040, and the bid documents were originally issued on August 8, 2025, with an addendum released on September 24, 2025.
The plans specify detailed technical requirements for removing existing drinking fountains, extending water and electrical connections, and installing new barrier-free hydration stations. The new fixtures are Elkay model LZS8WSLP electric water coolers with bottle filling functionality, which will be provided by the owner. The project involves electrical work such as running new conduit and wiring, and plumbing work including extending cold water, vent, and sanitary pipes. The scope covers multiple areas including corridors, toilets, and mechanical rooms across different units of the school building, with careful consideration for maintaining existing building operations during the installation process.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| WCS - 2025 Bond - Asbestos Abatement for BP10.doc | DOC document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VESTIBULE
A100
LOBBY
A101
TICKETS/
CONCESSIONS
A102LIFT
A103
OFFICE
A105
CORRIDOR
A104
STAIR
A106
CORRIDOR
A107
MENS
TOILET
A109
WOMENS
TOILET
A108 JC
A111
CORRIDOR
A110
CORRIDOR
A112
VESTIBULE
A113
VESTIBULE
A114
HOUSE
A115
STAIR
A117
ORCHESTRA
PIT
A116
VESTIBULE
A118
IDF
A119
CHURCH
STORAGE
A120
STAIR
A121
VESTIBULE
A122
STAGE
A123
CORRIDOR
A126
INSTRUMENTAL
A127
OFFICE
A128
PASSAGE
A129
PRACTICE
A131
PRACTICE
A130
INSTRUMENT
STORAGE
A132
VOCAL
A136
PRACTICE
A134
PRACTICE
A133
OFFICE
A135
DIMMER
ROOM
A125
VESTIBULE
A124
VESTIBULE
D101
CORRIDOR
D100
FIRE
PUMP
D102
ELEC
D103
SCENE
STORAGE
D105
AUTO SHOP
D106
OFFICE
D107
STORAGE
D108
STORAGE
D109
STORAGE
D110
STORAGE
D111
PARTS
STORAGE
D112
STORAGE
D113
DUST
STORAGE
D114
SCENE SHOP/
WOOD SHOP
D115
ENGLISH/DRAMA
CLASSROOM
D116
CAFETERIA
SEATING
D117
CORRIDOR
A137
CORRIDOR
B113
JC
B114
MENS
TOILET
B115
TEACHER
WORKROOM
B116
CLASSROOM
B118
CLASSROOM
B119
OFFICE
B121
CLASSROOM
B120 PASSAGE
B122
WORKROOM
B124
CLASSROOM
B125
CORRIDOR
B126
CLASSROOM
B127
CLASSROOM
B128
CLASSROOM
B129
CLASSROOM
B130
CORRIDOR
E101
STORAGE
B117
TECH
B123
OFFICE
B136
OFFICE
B137
OFFICE
B139
OFFICE
B140
OFFICE
B141
MAIN ELEC
ROOM
B142
SPECIAL
EDUCATION
C100
CLASSROOM
B131
CLASSROOM
C106
CLASSROOM
C107
CLASSROOM
C108
CLASSROOM
C109
CORRIDOR
C110
CLASSROOM
C111
CLASSROOM
C112
CLASSROOM
C113
CLASSROOM
C114
WORKROOM
C105AP OFFICE
C104
OFFICE
C103
SCHEDULING
OFFICE
C102
OFFICE
C101
CORRIDOR
C210
CLASSROOM
C115
CLASSROOM
C116
CLASSROOM
C120
OFFICE
C117
PASSAGE
C118
OFFICE
C119
CLASSROOM
C121
TOILET
ROOM
C122
TOILET
ROOM
C123
WOMENS
TOILET
F126
MECH
ROOM
F125
CLASSROOM
C124
CORRIDOR
F128
MAIN
OFFICE
B101
OFFICE
B104LIASON
B102
OFFICE
B103
OFFICE
B105
PASSAGE
B106
CLINIC
B107
MONITOR
B111
CONFERENCE
ROOM
B112
STR
B108
TOILET
B110
PROPS
STORAGE
A138
INSTRUMENT
STORAGE
A139
ENSEMBLE
ROOM
A140
OFFICE
A141
OFFICE
A144
STUDENT
INSTRUMENT
A145
STRINGS
STORAGE
A146
MUSIC
LIBRARY
A147
JC
A148
WOMENS
DRESSING
A150
PASSAGE
A152
TOILET
A151
PASSAGE
A153
MENS
DRESSING
A155
TOILET
A154
ROBE/UNIFOMR
GEN STOR
A149
CAREER
TECH
A143
STAIR
E102
JC
E103
TOILET
E105
TOILET
E106
PASS
E104
OFFICE
E139
OFFICE
E140
HEALTH
CLASSROOM
E107
OFFICE
E137
OFFICE
E143
OFFICE
E142
OFFICE
E136
OFFICE
E135
OFFICE
E134
OFFICE
E133
OFFICE
E132
OFFICE
E130
STORAGE
E126
STORAGE
E129
GUIDANCE
OFFICE
E144
CONF
ROOM
E125
CONF
ROOM
E128
GROIUP
ROOM
E124
CLASSROOM
E123
VIDEO ROOM
E122
RADIO/TV CR
E121
STORAGE
B131
DARK ROOM
E115
CLASSROOM
H109
WOMENS
TOILET
H108
CORRDIOR
H100
CLASSROOM
E120DARK
ROOM
E119
YEARBOOK
E117
PHOTOGRAPHY
E114
PASS
E118
STUDENT
ACTIVITIES
E113
MARKETING
CLASSROOM
E112
OFFICE
E111
STORAGE
H106
KILN
ROOM
H105
ART
CLASSOOM
H104
STORAGE
H103
OFFICE
H102
ART
CLASSROOM
H101
WOMENS
TOILET
E109
MENS
TOILET
E108
STUDENT
STORE
E110
STORAGE
E116
CORRDIOR
H107
WORK RM
F123
OFFICE
F120
LMC
OFFICE
F121
LMC
WORK ROOM
F122
OPEN
LEARNING
F115
CORRIDOR
J128
MENS
TOILET
F108
MECH
ROOM
F109
FLEX
SPACE
F113
BOOK
STACKS
F112
BOOK
STACKS
F111
TECH
F106
STORAGE
E146
COMPUTER
LAB
E147
OFFICE
E148
COMPUTER
LAB
E150
OFFICE
E151
CORRIDOR
F100
COMPUTER
LAB
F101
OFFICE
F102
COMPUTER
LAB
F103
CORRIDOR
F105
CORRIDOR
F104
STR
E149
OFFICE
J107
CLOSET
H135
STORAGE
H136
ATTENDANCE
OFFICE
H137OFFICE
H134
STAFF
TOILET
H133
WORK ROOM
H132
TEACHER
WORKROOM
J100
OFFICE
J101
WOMENS
TOILET
J102
MENS
TOILET
J103
OFFICE
J105
OFFICE
J106
CLASSROOM
J108
STORAGE
J122
STORAGE
J123
HOME
ECON
J121
COMPUTER
ROOM
J124
CLASSROOM
J126
TOILET
ROOM
J127
VEST
J129
SOUTH
CAFETERIA
D119
KITCHEN
D124
DISHWASH
D125
REFRIGERATOR
D127
OFFICE
D128
STORAGE
D122
FREEZER
D121
PASSAGE
D120
JC
D130
COMP
D131
TOILET
D132
STORAGE
D133
BAKERY
D129
NORTH
CAFETERIA
D134
CORRIDOR
G100
CORRIDOR
D126
CORRIDOR
D118
STORAGE
G120STORAGE
G110 JC
G119
STAIR
G109
OUTSIDE
STORAGE
G101
RECEIVING
G102
TEAM
ROOM
G111
CUSTODIAN WORK
AREA
G104 OFFICE
G103
MAIN ELEC
ROOM
G105
MENS LOCKERS/
CUST TOILET
G106
BOILER
ROOM
G107
TRAINING
G114
UNISEX
CHANGING
G112
OFFICE
G115
OFFICE
G116
CORRIDOR
G108
CORRIDOR
G117
STAIR
G113 STAIR
G132
GYMNASIUM
G118
CONCESSIONS
G122 STAIR
G123
MACHINE
G124
ELEV
G125
TICKET
G128 STAIR
G127
STORAGE
G129
CENTRAL
BOOK
G130
ATHLETIC
STORAGE
G131
PASSAGE
G133
STORAGE
G134
STORAGE
G135
CORRIDOR
G136 VEST
G137
CORRIDOR
G126
BIOLOGY
CLASSROOM
H110
PREP
ROOM
H112
BIOLOGY
LAB
H111
PASS
L110
PREP
ROOM
H114
BIOLOGY
CLASSROOM
H115
BIOLOGY
CLASSROOM
H116
PREP
ROOM
H120
PASS
H121
BIOLOGY
LAB
H119
OFFICE
H122
BIOLOGY
CLASSROOM
H123
CLASSROOM
H130
CLASSROOM
H131
CORRIDOR
H129
CHEMISTRY
CLASSROOM
L101
OFFICE
L103
PHYSICS
LAB
H128
WORK
ROOM
H127
WORK
ROOM
H126
STORAGE
H125
CORRDIOR
H124
LAB
L119
CLASSROOM
J110
CLASSROOM
J111
CLASSROOM
J112
CLASSROOM
J113
CLASSROOM
J114
CLASSROOM
L121
CLASSROOM
L133
CLASSROOM
J116
OFFICE
J117
CLASSROOM
J118
CLASSROOM
J119
CLASSROOM
J120
CORRDIOR
J115
STAIR
G139
CORRIDOR
G138
WOMENS POOL
LOCKER RM
G141
CHANGING
G143
TOILET
G142
WOMENS COACHES
OFFICE
G150
TOILET
G151
CORRIDOR
G157
SHOWER
G149
SHOWER
G152
CORRIDOR
G144
TOILET
G148
STORAGE
G146 TOILET
G145
PASSAGE
G147
TOILET
K104
WOMENS GYM
LOCKER RM
G156
CHANGING
G153
JC
G158
TOILET
G155
TEAM
ROOM
G159
STORAGE
G160
STORAGE
G161
CHANGING
G162
MENS GYM
LOCKER RM
G164
CORRIDOR
G166
LOCKER RM
G167
TOILET
G168
TOILET
G165
SHOWER
G163
TOILET
G169
SHOWER
G171
STAIR
G180
MENS
LOCKER RM
G170
MENS POOL
LOCKER RM
G178
TOILET
G177
TOILET
G172
PASSAGE
G173TRAINING
G174
STORAGE
G175TOILET
G176
POOL
MECHANICAL
K102
PASS
G140
TOILET
K105
STORAGE
K106
PASSAGE
K107
STORAGE
K108
OFFICE
K111
CONF
ROOM
K110
OFFICE
K112
NATATORIUM
K103
STAIR
K100
STORAGE
K101
OFFICE
L105
CHEMISTRY
LAB
L102
CHEMISTRY
CLASSROOM
L107
CHEMISTRY
CLASSROOM
L112
OFFICE
L111
PREP
ROOM
L109
CHEMISTRY
LAB
L108
CORRDIOR
L113
CORRDIOR
L118
EARTH SCIENCE
LAB
L117
OFFICE
L116
WORK
ROOM
L115
EARTH SCIENCE
LAB
L114
CLASSROOM
J109
CLASSROOM
L123
CLASSROOM
L124
CLASSROOM
L125
CLASSROOM
L126
CLASSROOM
L128
CLASSROOM
L129
CLASSROOM
L130
CLASSROOM
L131
CLASSROOM
L132
CORRDIOR
L122
CORRDIOR
L127
CORRIDOR
K113VEST
K114
GYMNASIUM
SOUTH
K115
GYMNASTICS
K122
STORAGE
K120
JC
K121
MACHINE
ROOM
K117
ELEV
K118
LOCKER ROOM
M103PASSAGE
M102
TOILET
M106
TOILET
M107
STAIRS
M109
UNIT D
UNIT A
U N
IT
A
U N
IT
B
CORRIDOR
A142
VESTIBULE
B100
PASSAGE
B109
CLASSROOM
B132
CLASSROOM
B133
CLASSROOM
B134
CLASSROOM
B135
PASS
B138
PASS
D104
PASSAGE
D123
CORRIDOR
E100
PASS
E127
PASS
E138
PASS
E141
CORRIDOR
E145
PASS
F107
MEDIA
CENTER
F114
CORR
F119
CORR
F124
CORRIDOR
F127
VEST
F129
STORAGE
F110
STORAGE
G121
CORRIDOR
G179
STORAGE
G154
VEST
H117
STOR
H118
CORRIDOR
J104
STORAGE
J125
CORRIDOR
K109
CORRIDOR
K116
STORAGE
K119
GYMNASIUM
SOUTH
M100
GYMNASTICS
M101
LOCKER ROOM
M104
LOCKER ROOM
M105
WIEGHT ROOM
M108
UNIT F
UNIT C
UNIT J
UNIT F
U N
IT
B
U N
IT
C
U N
IT
G
U N
IT
D
U N
IT
G
U N
IT
H
U N
IT
H
U N
IT
J
UNIT K
UNIT G
UNIT K
UNIT G
UNIT L
UNIT H
CORRDIOR
L100
CHEMISTRY
CLASSROOM
L106
CORRDIOR
L120
UNIT L
UNIT H
UNIT L
UNIT J
UNIT L
UNIT J
UNIT M
UNIT K
UNIT M
UNIT K
PASS
L104
PASS
L110
C O
PI
ER
ENTRY
F117
C O
PI
ER
COPIER
OFFICE
H138
COPIER
FE
B
R F
SCALE:
COMPOSITE FIRST FLOOR PLAN
1/64" = 1'-0"
VEST
K201
STORAGE
K201
ELEV
K202
STAIRS
K203
STORAGE
K204
PASS
K205
MECH
K206
ACTIVITY
K207
ACTIVITY
M200
TBD
M201
STORAGE
M202
MECH
M203
ACTIVITY
M204
STAIRS
M205
UPPER
NATATORIUM
G200
MECHANICAL
G201
UNIT D
UNIT A
U N
IT
A
U N
IT
B
U N
IT
G
U N
IT
D
U N
IT
G
U N
IT
H
UNIT K
UNIT G
UNIT K
UNIT G
UNIT M
UNIT K
UNIT M
UNIT K
TBD
M206
SCALE:
COMPOSITE SECOND FLOOR PLAN
1/64" = 1'-0"
A2.01
COMPOSITE
PLAN
09/24/2025 ADDENDUM 1
ISSUE DATE ISSUED FOR
CHECKED
APPROVED
DRAWN
PROJECT
SHEET
PROJECT NUMBER
SHEET NUMBER
08/08/2025 BIDS
Livonia Public Schools Hydration Stations Stevenson High School
LIVONIA,
MICHIGAN
2025-040
-0
LP
S
HY
DR
AT
IO
N
ST
AT
IO
NS
GRS
AMN
DCJ
KEY PLAN
E D
F
G H J
K
A B C
L L
M
2851 High Meadow Circle | Suite 100 Auburn Hills | MI 48326
248.656.1377
ADD
AutoCAD SHX Text
MAX Q
AutoCAD SHX Text 21x48
AutoCAD SHX Text 533x1219
AutoCAD SHX Text
MAX Q
AutoCAD SHX Text 21x48
AutoCAD SHX Text 533x1219
AutoCAD SHX Text
MAX Q
AutoCAD SHX Text 21x48
AutoCAD SHX Text 533x1219
AutoCAD SHX Text
MAX Q
AutoCAD SHX Text 21x48
AutoCAD SHX Text 533x1219
AutoCAD SHX Text
MAX Q
AutoCAD SHX Text 21x48
AutoCAD SHX Text 533x1219
SCALE:
UNIT A FIRST FLOOR PLAN
3/32" = 1'-0"
VESTIBULE
A100
LOBBY
A101
TICKETS/
CONCESSIONS
A102LIFT
A103
OFFICE
A105
CORRIDOR
A104
STAIR
A106
CORRIDOR
A107
MENS
TOILET
A109
WOMENS
TOILET
A108 JC
A111
CORRIDOR
A110
CORRIDOR
A112
VESTIBULE
A113
VESTIBULE
A114
HOUSE
A115
STAIR
A117
ORCHESTRA
PIT
A116
VESTIBULE
A118
IDF
A119
CHURCH
STORAGE
A120
STAIR
A121
VESTIBULE
A122
STAGE
A123
CORRIDOR
A126
INSTRUMENTAL
A127
OFFICE
A128
PASSAGE
A129
PRACTICE
A131
PRACTICE
A130
INSTRUMENT
STORAGE
A132
VOCAL
A136
PRACTICE
A134
PRACTICE
A133
OFFICE
A135
DIMMER
ROOM
A125
VESTIBULE
A124
VESTIBULE
D101
CORRIDOR
D100
CORRIDOR
A137
PROPS
STORAGE
A138
INSTRUMENT
STORAGE
A139
ENSEMBLE
ROOM
A140
OFFICE
A141
OFFICE
A144
STUDENT
INSTRUMENT
A145
STRINGS
STORAGE
A146
MUSIC
LIBRARY
A147
JC
A148
WOMENS
DRESSING
A150
PASSAGE
A152
TOILET
A151
PASSAGE
A153
MENS
DRESSING
A155
TOILET
A154
ROBE/UNIFOMR
GEN STOR
A149
CAREER
TECH
A143
CORRIDOR
D118
UNIT D
UNIT A
U N
IT
A
U N
IT
B
CORRIDOR
A142
VEST
B100
5/8" HIGH IMPACT GYPSUM BOARD EACH SIDE OF METAL STUD AT 16" O.C.
REFER TO PARTITION TYPE TAG. ALL INTERIOR PARTITIONS TO
UNDERSIDE OF DECK U.N.O.
EXTERIOR WALLS TO BE 4" NOMINAL BRICK ON CONCRETE BLOCK WALL
WITH 3" RIGID CAVITY INSULATION
C.M.U. PARTITION AS DIMENSIONED. REFER TO PARTITION TYPE TAG.
FLOOR PLAN LEGEND
INDICATES BATT SOUND ATTENUATION INSULATION
FLOOR PLAN NOTES
ALL INTERIOR PARTITIONS SHALL EXTEND UP TO UNDERSIDE OF ROOF DECK
UNLESS OTHERWISE INDICATED.
PATCH ALL HOLES FROM REMOVED ITEMS SUCH AS, BUT NOT LIMITED TO
THERMOSTATS, NAIL HOLES, WALL MOUNTED CASEWORK, ETC.
COURSE IN NEW BRICK TO MATCH EXISTING WHERE PLUMBING WORK IS BEING
DONE. TOOTH-IN TO MATCH COURSING - TYPICAL.
1.
2.
3.
ALL INTERIOR WALLS TO EXTEND TO DECK UNLESS OTHERWISE
INDICATED.
PARTITION TYPE. REFER TO SHEET A0.03 FOR PARTITION
TYPES LEGENDX-X12
GENERAL NOTES
ALL STUD PARTITIONS TO BE TYPE U.N.O.1.
ALL MASONRY PARTITIONS TO BE TYPE U.N.O.2.
S4
M8
ALL GYP. BD. IN CLASSROOMS AND CORRIDORS TO BE HIGH IMPACT3.
USE EXISTING
CONNECTIONS FOR
INSTALLATION OF
COMPLIANT FOUNTAIN
A3.02A
A
CH4
±4'-4 3/4"
A2.10A
UNIT A
FIRST FLOOR PLAN
09/24/2025 ADDENDUM 1
ISSUE DATE ISSUED FOR
CHECKED
APPROVED
DRAWN
PROJECT
SHEET
PROJECT NUMBER
SHEET NUMBER
08/08/2025 BIDS
Livonia Public Schools Hydration Stations Stevenson High School
LIVONIA,
MICHIGAN
2025-040
-0
LP
S
HY
DR
AT
IO
N
ST
AT
IO
NS
GRS
AMN
DCJ
KEY PLAN
E D
F
G H J
K
A B C
L L
M
2851 High Meadow Circle | Suite 100 Auburn Hills | MI 48326
248.656.1377
ADD
ROOM FINISH SCHEDULE REMARKS
1. PATCH AND PAINT WALL AND INSTALL NEW WALL BASE AS REQUIRED FOR NEW HYDRATION STATIONS
2. INSTALL NEW WALL TILE ON NEW CHASE WALL (FULL HEIGHT) FOR NEW HYDRATION STATIONS - REFER TO ELEVATIONS
ROOM FINISH SCHEDULE GENERAL NOTES
ROOM FINISH SCHEDULE ABBREVIATIONS
A. PAINTING OF EXISTING WALLS - REMOVE ALL EXISTING CLOCKS, SPEAKERS, SWITCH PLATE COVERS, OUTLET COVERS, THERMOSTATS, DIFFUSERS, GRILLES, REGISTERS, BLINDS, SHADES, EQUIPMENT, MARKERBOARDS, TACKBOARDS, ARTWORK AND OTHER MATERIALS PRIOR TO PAINTING AND RE-INSTALL IN THE SAME LOCATION AFTER PAINTING IS COMPLETE. PAINT ANY ITEMS THAT ARE CURRENTLY THE SAME COLOR AS THE EXISTING WALL. PAINT EXISTING CONDUIT TO MATCH THE WALL. PROTECT EXISTING FIRE ALARM DEVICES TO REMAIN IN PLACE.
B. SEE THE A7 & A9 SERIES SHEETS FOR PAINT DESIGNATIONS.
C. SEE THE A9 SERIES SHEETS FOR FLOOR PATTERNS.
D. PROVIDE RADIUS EDGE AT COUNTERTOPS.
E. DO NOT PAINT OVER EXISTING MURALS, LETTERS, QUOTES, ETC. UNLESS NOTED OTHERWISE AND DIRECTED BY OWNER
F. DO NOT PAINT OVER ANY EXISTING EXPOSED BRICK
H. PROVIDE METAL SCHLUTER STRIP AT BOTTOM OF NEW WALL TILE AND OUTSIDE WALL CORNERS - TYP.
I. ALL AREAS OF PEELING COATING MUST BE REMOVED TO A SOUND SUBSTRATE AND CLEANED TO REMOVE ANY OILS, GREASE OR OTHER SOLUBLE CONTAMINANTS.
STAINLESS STEEL
SPLIT FACE CMU
SPORTS IMPACT
SHEET VINYL
TERRAZZO
VINYL COMPOSITION TILE
WATERPROOF
SS
SP CMU
SPI
SV
TER
VCT
WP
SSM SOLID SURFACE MATERIAL
EXPO
EXIST
CT
CPT
CPL
CONC
CMU
BRICK
B CMU
ANOD
ACT
GLASS
EXPOSED
EXISTING
CERAMIC TILE
CARPET
CEMENT PLASTER
CONCRETE
CONCRETE MASONRY UNIT
BRICK
BURNISHED CMU
ANODIZED
ACOUSTICAL CEILING TILE
RBF
QT
PTD
PT
PLAS
PLAM
PART'N
NSF
MP
LMC
GYP
GCMU
RUBBER TILE
QUARRY TILE
PAINTED
PORCELAIN TILE
VENEER PLASTER
PLASTIC LAMINATE
MOVEABLE PARTITION
NON-SLIP FINISH
METAL PANEL
LINEAR METAL CEILING
GYPSUM BOARD
GLAZED CMU
SEAL
SAAC
RB
CONCRETE SEALER
SPRAY-APPLIED ACOUSTICAL COATING
RESILIENT WALL BASE
MATCH EXISTINGMA EX
GL
ROOM FINISH SCHEDULE UNIT A
RM.
NO. ROOM NAME
MAT. FINISH
FLOOR
MAT. FINISH
BASE
MAT. FINISH
NORTH
MAT. FINISH
EAST
MAT. FINISH
SOUTH
MAT. FINISH
WEST
WALLS
DOOR
FRAME
MAT. FINISH HGT.
CEILING
M/C FINISH
MILLWORK/CASEWORK
REMARKS
A110 CORRIDOR - - - - - - - - GYP CT3/C4 - - - - - - - - 2
ROOM FINISH SCHEDULE UNIT B
RM.
NO. ROOM NAME
MAT. FINISH
FLOOR
MAT. FINISH
BASE
MAT. FINISH
NORTH
MAT. FINISH
EAST
MAT. FINISH
SOUTH
MAT. FINISH
WEST
WALLS
DOOR
FRAME
MAT. FINISH HGT.
CEILING
M/C FINISH
MILLWORK/CASEWORK
REMARKS
B131 CLASSROOM - - EX/RB EX/B1 - - - - - - EX/CMU EX/ P1SG-A - - - - - - 1
ROOM FINISH SCHEDULE UNIT F
RM.
NO. ROOM NAME
MAT. FINISH
FLOOR
MAT. FINISH
BASE
MAT. FINISH
NORTH
MAT. FINISH
EAST
MAT. FINISH
SOUTH
MAT. FINISH
WEST
WALLS
DOOR
FRAME
MAT. FINISH HGT.
CEILING
M/C FINISH
MILLWORK/CASEWORK
REMARKS
F104
F108
CORRIDOR
MENSTOILET
EX/RB
EX/RB
EX/B1
EX/B1
EX/CMU
EX/P1SG-A
EX/CMU
EX/P1SG-A
KEY MANUFACTURER STYLE COLOR DESCRIPTION INSTALLATION / LOCATION NOTES
C
EI
LI
N
G
W
AL
L
BA
SE
B1 TARKETT RUBBER WALL BASE MATCH EXISTING ROLLED RUBBER GOOD -
FL
O
O R
IN
G
W
AL
L
TI
LE
CT3 DALTILE COLOR WHEEL CLASSIC COLOR TBD 3" x 6" DRINKING FOUNTAIN TILE
CT4 DALTILE COLOR WHEEL CLASSIC COLOR TBD 3" X 6" DRINKING FOUNTAIN TILE
PA
IN
T
P1SG-A SHERWIN WILLIAMS MATCH EXISTING SHEEN MATCH EXISTING SINGLE COMPONENT EPOXY MATCH EXISTING FIELD COLOR
M
IL
LW
O
R K
M
IS
C
EL
LA
N
EO
U
S
MATERIAL AND COLOR SCHEDULE
SCALE:
CORRIDOR A110
1/4" = 1'-0" A
A2.10A
Bottles savedFilter status
Bottles savedFilter status
NEW STUD CHASE
WALL WITH
DRYWALL BEHIND
CT3
PLUMBING FIXTURES
- SEE MECH
CT4
CT3
A3.02A
ROOM FINISH
SCHEDULE, MATERIAL
AND COLOR
SCHEDULE
09/24/2025 ADDENDUM 1
ISSUE DATE ISSUED FOR
CHECKED
APPROVED
DRAWN
PROJECT
SHEET
PROJECT NUMBER
SHEET NUMBER
08/08/2025 BIDS
Livonia Public Schools Hydration Stations Stevenson High School
LIVONIA,
MICHIGAN
2025-040
-0
LP
S
HY
DR
AT
IO
N
ST
AT
IO
NS
GRS
AMN
DCJ
KEY PLAN
E D
F
G H J
K
A B C
L L
M
2851 High Meadow Circle | Suite 100 Auburn Hills | MI 48326
248.656.1377
ADD
ADD
ADD
ADD
ADD
(E)DF
(E)DF1
MENS
TOILET
F108
GENERAL DEMOLITION NOTES
A
THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL
EXTENT OF WORK TO BE PERFORMED. THE EXACT EXTENT OF
DEMOLITION SHALL BE DETERMINED BY THE NEW WORK.
B
ANY INTERRUPTIONS OF EXISTING SERVICES AND/OR EQUIPMENT SHALL
BE PERFORMED AT A TIME APPROVED IN ADVANCE BY OWNER'S
REPRESENTATIVE SO AS NOT TO INTERFERE WITH THE PRESENT
BUILDING'S OPERATION.
C
PRIOR TO COMMENCEMENT OF WORK, CONTRACTOR SHALL VISIT THE
SITE AND BECOME FAMILIAR WITH EXISTING SITE CONDITIONS,
SYSTEMS, AND UTILITIES. NOTIFY DESIGN PROFESSIONAL OF ANY
INTERFERENCES OR DISCREPANCIES.
D
ALL ITEMS INDICATED WITH CROSS-HATCHING SHALL BE REMOVED
COMPLETELY WITH ALL RELATED ITEMS INCLUDING HANGERS,
SUPPORTS, INSULATION, CONTROLS, ETC. CAP ALL OPEN-ENDED PIPES
AND DUCTS.
E
THE OWNER SHALL HAVE FIRST RIGHT OF REFUSAL ON ALL EQUIPMENT
BEING REMOVED. ALL ITEMS REMOVED SHALL BE LEGALLY DISPOSED OF.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXISTING
RELOCATED AND OWNER-PROVIDED EQUIPMENT.
F
VERIFY DEPTH, SIZE, LOCATIONS, AND CONDITIONS OF EXISTING
UTILITIES IN THE FIELD, INCLUDING POINTS OF CONNECTION, PRIOR TO
STARTING WORK.
G
ALL ITEMS ON DEMOLITION PLAN SHALL BE CONSIDERED EXISTING
UNLESS OTHERWISE NOTED. ALL WORK INDICATED ON PLANS HAS BEEN
LOCATED PER EXISTING DRAWINGS AND/OR FIELD OBSERVATION AND
REQUIRES FIELD VERIFICATION.
H
ALL EXISTING WORK TO REMAIN SHALL BE PROTECTED FROM DAMAGE.
WHERE DUCT WORK PIPE INSULATION HAS BEEN DAMAGED DURING
DEMOLITION, THE CONTRACTOR SHALL REPAIR INSULATION AS
REQUIRED TO MATCH EXISTING.
DEMOLITION KEYED NOTES
1 REMOVE DRINKING FOUNTAIN/BOTTLE FILLING STATION COMPLETE. REMOVE
STOPS, TEMPORARILY CAP, AND PREPARE PIPING FOR NEW CONNECTION.
X
(E)DF
(E)DF
MENS
TOILET
B115
1(E)DF
CORRIDOR
A110
CORRIDOR
A112
(E)DF
(E)CP
(E)DF1
MECH
M203
EWC-1 1
EWC-12
MECH
M203
CORRIDOR
A110
CORRIDOR
A112
EWC-1 2
EWC-1 1
MENS
TOILET
B115
CORRIDOR
E101
PLUMBING GENERAL NOTES
A
THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL
EXTENT OF WORK TO BE PERFORMED. THE EXACT EXTENT OF
DEMOLITION SHALL BE DETERMINED BY THE NEW WORK.
B
ANY INTERRUPTIONS OF EXISTING SERVICES AND/OR EQUIPMENT SHALL
BE PERFORMED AT A TIME APPROVED IN ADVANCE BY THE OWNER'S
REPRESENTATIVE SO AS NOT TO INTERFERE WITH THE PRESENT
BUILDING'S OPERATION.
C
PRIOR TO COMMENCEMENT OF WORK, CONTRACTOR SHALL VISIT THE
SITE AND BECOME FAMILIAR WITH EXISTING SITE CONDITIONS,
SYSTEMS, AND UTLITIES. NOTIFY DESIGN PROFESSIONAL OF ANY
INTERFERENCES OR DISCREPANCIES.
D
ALL ITEMS INDICATED WITH CROSS-HATCHING SHALL BE REMOVED
COMPLETE WITH ALL RELATED ITEMS INCLUDING HANGERS, SUPPORTS,
INSULATION, CONTROLS, ETC. CAP ALL OPEN ENDED PIPES AND DUCTS.
E
THE OWNER SHALL HAVE FIRST RIGHT OF REFUSAL ON ALL EQUIPMENT
BEING REMOVED. ALL ITEMS REMOVED SHALL BE LEGALLY DISPOSED OF.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXISTING
RELOCATED AND OWNER PROVIDED EQUIPMENT.
F
VERIFY DEPTH, SIZE, LOCATIONS, AND CONDITIONS OF EXISTING
UTILITIES IN THE FIELD. INCLUDING POINTS OF CONNECTION PRIOR TO
STARTING ANY WORK.
G
ALL ITEMS ON DEMOLITION PLAN SHALL BE CONSIDERED EXISTING
UNLESS OTHERWISE NOTED. ALL WORK INDICATED ON PLANS HAS BEEN
LOCATED PER EXISTING DRAWINGS AND/OR FIELD OBSERVATION AND
REQUIRES FIELD VERIFICATION.
H
ALL EXISTING WORK TO REMAIN SHALL BE PROTECTED FROM DAMAGE.
WHERE DUCT WORK PIPE INSULATION HAS BEEN DAMAGED DURING
DEMOLITION, THE CONTRACTOR SHALL REPAIR INSULATION AS
REQUIRED TO MATCH EXISTING.
J
INSTALL ALL SANITARY AND STORM PIPING 2 1/2" OR LESS AT 1/4" PER
FOOT AND 3" AND LARGER PIPING AT 1/8" PER FOOT MINIMUM UNLESS
NOTED OTHERWISE. MINIMUM UNDERGROUND PIPE SIZE SHALL BE 3".
K PROVIDE "INLINE" WATERLESS PRIMER TRAP SEAL PROTECTION ON ALL
FLOOR DRAINS AND TRAPS SUBJECT TO EVAPORATION.
L AT EACH CONNECTION OF GAS SUPPLY TO EQUIPMENT, PROVIDE A PIPE
UNION, GAS SHUT OFF VALVE, TEE, AND 6" LONG DIRT LEG WITH CAP.
M
THE CEILING SPACE IS USED AS A RETURN AIR PLENUM. NO PLASTIC
MATERIALS INCLUDING PVC PIPING, CONDUIT WIRING, ETC. SHALL BE
USED. ALL MATERIALS TO BE USED ARE TO BE PLENUM RATED.
NEW WORK KEYED NOTES
EXTEND 1/2" CW, 1 1/2" V, AND 1 1/2" SAN FROM PIPING IN WALL AND CONNECT
TO ELECTRIC WATER COOLER. TERMINATE WITH STOPS. REMOVE BLOCK WALL
AS REQUIRED FOR INSTALLATION. SEE ARCHITECTURAL DRAWINGS FOR MORE
INFORMATION.
EXTEND AND REARRANGE 1/2" CW, 1 1/2" V, AND 1 1/2" SAN FROM EXISTING
PIPING IN FURRED OUT WALL AND CONNECT TO TWO ELECTRIC WATER
COOLERS. TERMINATE WITH STOPS. MINIMUM DISTANCE FROM CENTER OF EACH
FIXTURE TO ADJACENT WALL SHALL BE 15". SEE ARCHITECTURAL DRAWINGS FOR
MORE INFORMATION.
X
EWC-11
MENS
TOILET
F108
PLUMBING FIXTURE SCHEDULE
TAG BARRIER
FREE ITEM
PIPE CONNECTION SIZES MANUFACTURER &
MODEL NO. ACCESSORIES
WASTE VENT CW HW
EWC-1 Y
FILTERED ELECTRIC
WATER COOLER WITH
BOTTLE FILLER
1 1/2" 1 1/2 1/2" - ELKAY: LZS8WSLP
FIXTURE TO BE PROVIDED BY
OWNER. CONTRACTOR TO PROVIDE
CANE APRON ELKAY: LKAPREZL
EWC-2 - NOT USED - - - - - -
NOTES:
1. PROVIDE ALL ACCESSORIES NECESSARY FOR COMPLETE AND OPERABLE INSTALLATION.
2. ALL FIXTURES SHALL MEET MICHIGAN DEPT. OF PUBLIC HEALTH REQUIREMENTS, AND SHALL BE SUITABLE FOR FOOD PREPARATION AREAS.
ENLARGED PLUMBING
DEMOLITION AND NEW
WORK PLANS
P4.10
ISSUE DATE ISSUED FOR
CHECKED
APPROVED
DRAWN
PROJECT
SHEET
PROJECT NUMBER
SHEET NUMBER
MPH
MPH
MB
2851 High Meadow Circle | Suite 100 Auburn Hills | MI 48326
248.656.1377
UNIFIED BUILDING
SYSTEMS ENGINEERING
UBS PROJECT 029.25.08 - ST
69 S. GRATIOT AVE.
MT. CLEMENS, MI 48043
2025-xxx.x
X
2025-040.0
-0
.0
LP
S
HY
DR
AT
IO
N
ST
AT
IO
NS
Livonia Public Schools Hydration Stations
LIVONIA,
MICHIGAN
KEY PLAN
E D
F
G H J
K
A B C
L L
M
08/08/2025 BIDS
Stevenson High School
SCALE:
ENLARGED PLUMBING
DEMOLITION PLAN - F-108
1/4" = 1'-0"
P1.01
SCALE:
ENLARGED PLUMBING DEMOLITION
PLAN - B-115 / CORRIDOR E-101
1/4" = 1'-0"
P1.01
SCALE:
ENLARGED PLUMBING DEMOLITION
PLAN - CORRIDOR A-110
1/4" = 1'-0"
P1.01
SCALE:
ENLARGED PLUMBING DEMOLITION
SECOND FLOOR PLAN - M-203
1/4" = 1'-0"
P1.02
SCALE:
ENLARGED PLUMBING
NEW WORK PLAN - F-108
1/4" = 1'-0"
P1.01
SCALE:
ENLARGED PLUMBING NEW WORK
PLAN - B-115 / CORRIDOR E-101
1/4" = 1'-0"
P1.01
SCALE:
ENLARGED PLUMBING NEW WORK
PLAN - CORRIDOR A-110
1/4" = 1'-0"
P1.01
SCALE:
ENLARGED PLUMBING NEW WORK
SECOND FLOOR PLAN - M-203
1/4" = 1'-0"
P1.02
ADDENDUM 0109/24/2025
AutoCAD SHX Text
OS
OS
GENERAL DEMOLITION NOTES
A
THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL
EXTENT OF WORK TO BE PERFORMED. THE EXACT EXTENT OF
DEMOLITION SHALL BE DETERMINED BY THE NEW WORK.
B
ANY INTERRUPTIONS OF EXISTING SERVICES AND/OR EQUIPMENT SHALL
BE PERFORMED AT A TIME APPROVED IN ADVANCE BY OWNER'S
REPRESENTATIVE SO AS NOT TO INTERFERE WITH THE PRESENT
BUILDING'S OPERATION.
C
PRIOR TO COMMENCEMENT OF WORK, CONTRACTOR SHALL VISIT THE
SITE AND BECOME FAMILIAR WITH EXISTING SITE CONDITIONS,
SYSTEMS, AND UTILITIES. NOTIFY DESIGN PROFESSIONAL OF ANY
INTERFERENCES OR DISCREPANCIES.
D
ALL ITEMS INDICATED WITH CROSS-HATCHING SHALL BE REMOVED
COMPLETELY WITH ALL RELATED ITEMS INCLUDING HANGERS,
SUPPORTS, INSULATION, CONTROLS, ETC. CAP ALL OPEN-ENDED PIPES
AND DUCTS.
E
THE OWNER SHALL HAVE FIRST RIGHT OF REFUSAL ON ALL EQUIPMENT
BEING REMOVED. ALL ITEMS REMOVED SHALL BE LEGALLY DISPOSED OF.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL EXISTING
RELOCATED AND OWNER-PROVIDED EQUIPMENT.
F
VERIFY DEPTH, SIZE, LOCATIONS, AND CONDITIONS OF EXISTING
UTILITIES IN THE FIELD, INCLUDING POINTS OF CONNECTION, PRIOR TO
STARTING WORK.
G
ALL ITEMS ON DEMOLITION PLAN SHALL BE CONSIDERED EXISTING
UNLESS OTHERWISE NOTED. ALL WORK INDICATED ON PLANS HAS BEEN
LOCATED PER EXISTING DRAWINGS AND/OR FIELD OBSERVATION AND
REQUIRES FIELD VERIFICATION.
H
ALL EXISTING WORK TO REMAIN SHALL BE PROTECTED FROM DAMAGE.
WHERE DUCT WORK PIPE INSULATION HAS BEEN DAMAGED DURING
DEMOLITION, THE CONTRACTOR SHALL REPAIR INSULATION AS
REQUIRED TO MATCH EXISTING.
DEMOLITION KEYED NOTES
RECEPTACLE TO BE REMOVED COMPLETE. TAKE CONDUIT AND WIRING
BACK TO SOURCE. PREP CIRCUIT FOR CONNECTION TO NEW
RECEPTACLE. REFER TO NEW WORK PLANS.
X
CORRIDOR
A110
CORRIDOR
A112
MECH
M203
EWC-1
EWC-1
GF
I
GFI
CP-FITNESS-10
CP-FITNESS-12
CORRIDOR
A110
CORRIDOR
A112
EWC-1
GFI
GFI
MENS
TOILET
B115
CORRIDOR
E101
EWC-1
CP
E) -R
P-
BB
-M
GFI
LP-D-21
NEW WORK KEYED NOTES
RUN NEW WIRE AND CONDUIT FOR NEW DRINKING FOUNTAIN GFCI
RECEPTACLE. RECEPTACLE SHALL BE READILY ACCESSIBLE. CIRCUIT TO
EXISTING SPARE 20A BREAKER AS SHOWN
2 EXTEND EXISTING SPARE CIRCUIT MADE AVAILABLE DURING
DEMOLITION. EXTEND CONDUIT AND WIRING AS REQUIRED.
X
POWER GENERAL NOTES
A
THESE DRAWINGS ARE DIAGRAMMAITC AND REPRESENT THE GENERAL
EXTENT OF THE WORK TO BE PERFORMED. PROVIDE AND EXECUTE ALL
HVAC SYSTEMS PER ENGINEER'S SPECIFICATION, AND LOCAL APPLICABLE
CODES INCLUDING AMENDMENTS, BULLETINS, ETC. AS WELL AS THE
STANDARDS OF INSTALLATION AND EQUIPMENT ESTABLISHED FOR THE
BUILDINGS, AND REQUIREMENTS OF THE OWNER.
B
EXCEPT FOR CHANGES AS MAY BE SPECIFICALLY APPROVED BY THE
ENGINEER OF RECORD. IN ACCORDANCE WITH ALTERNATES OF OPTIONS
AS STATED HEREINAFTER, ALL WORK MUST BE IN FULL ACCORDANCE
WITH THE INTENT OF THE PLANS AND SPECIFICATIONS. SYSTEMS ARE
TO BE COMPLETE, EFFICIENT, AND SATISFACTORY OPERATION WHEN
PROJECT IS DELIVERED TO THE OWNER.
D
CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS AND APPROVAL
FROM GOVERNING AUTHORITIES AND FILE NECESSARY FORMS, PAY ALL
INSPECTION FEES.
E
ELECTRICAL CONTRACTOR SHALL COMPLY WITH THE LATEST NATIONAL
ELECTRICAL CODE, LIFE SAFETY CODE AND APPLICABLE STATE AND
LOCAL CODES AND ORDINANCES.
F
ELECTRICAL EQUIPMENT AND WIRING SHALL BE NEW AND SHALL BE
FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR, UNLESS
OTHERWISE NOTED.
G WIRING SHALL BE IN CONDUIT. CONDUIT SHALL BE 3/4" CONDUIT
MINIMUM. CONDUITS IN FINISHED AREAS SHALL BE CONCEALED
H
NEW WIRES SHALL BE TYPE THHN. MINIMUM SIZE SHALL BE #12 AWG,
UNLESS OTHERWISE NOTED. FINAL CONNECTIONS TO EQUIPMENT,
FURNISHED AND INSTALLED BY OTHERS, SHALL BE PROVIDED BY THIS
CONTRACTOR.
MENS
TOILET
F108
EWC-1
GF
I
LP-E-34
ENLARGED ELECTRICAL
POWER DEMOLITION
AND NEW WORK PLANS
E4.10
ISSUE DATE ISSUED FOR
CHECKED
APPROVED
DRAWN
PROJECT
SHEET
PROJECT NUMBER
SHEET NUMBER
MPH
RDL
RDL
2851 High Meadow Circle | Suite 100 Auburn Hills | MI 48326
248.656.1377
UNIFIED BUILDING
SYSTEMS ENGINEERING
UBS PROJECT 029.25.08 - ST
69 S. GRATIOT AVE.
MT. CLEMENS, MI 48043
2025-xxx.x
X
2025-040.0
-0
.0
LP
S
HY
DR
AT
IO
N
ST
AT
IO
NS
Livonia Public Schools Hydration Stations
LIVONIA,
MICHIGAN
KEY PLAN
E D
F
G H J
K
A B C
L L
M
08/08/2025 BIDS
Stevenson High School
SCALE:
ENLARGED ELECTRICAL POWER
DEMOLITION PLAN - CORRIDOR A-110
1/4" = 1'-0"
E1.01
SCALE:
ENLARGED ELECTRICAL POWER
NEW WORK PLAN - F-108
1/4" = 1'-0"
E1.01
SCALE:
ENLARGED ELECTRICAL POWER
NEW WORK PLAN - B-115 / E-101
1/4" = 1'-0"
E1.01
SCALE:
ENLARGED ELECTRICAL POWER
NEW WORK PLAN - CORRIDOR A-110
1/4" = 1'-0"
E1.01
SCALE:
ENLARGED ELECTRICAL POWER
NEW WORK SECOND FLOOR PLAN - M-203
1/4" = 1'-0"
E1.02
ADDENDUM 0109/24/2025
OS
| 25040 STEVENSON A210A-A210A |
| 25040 STEVENSON ca01-A302A |
| P4.10 ENLARGED PLUMBING DEMOLITION AND NEW WORK PLANS |
| P4.10 ENLARGED PLUMBING DEMOLITION AND NEW WORK PLANS |
| E4.10 ENLARGED ELECTRICAL POWER DEMOLITION AND NEW WORK PLANS |
| E4.10 ENLARGED ELECTRICAL POWER DEMOLITION AND NEW WORK PLANS |
File details come from the government source that posted it. Updated .