25.10.08 S Wing Corridor Lighting - Drawings IFB.pdf

PDF 957 KB Posted

Attached to
Delta College S Wing Corridor Lighting
Solicitation number
2025010
Issued by
Bay County, Warren City, Michigan

About this file

This document is a set of architectural and electrical engineering drawings for the Delta College S-Wing Corridor Lighting project located at 1961 Delta Road in University Center, Michigan 48710. The project involves comprehensive lighting renovations across the lower, first, and second floors of the S-Wing, including detailed demolition and new construction lighting plans. The drawings are prepared by William A. Kibbe & Associates, Inc. and include multiple technical specifications, including building code compliance with 2021 Michigan Rehabilitation, Building, Plumbing, and Mechanical Codes, as well as the 2023 National Electric Code and 2015 International Fire Code.

The technical drawings provide extensive details about electrical work, including general notes on electrical installations, grounding applications, identification systems, and power conductor specifications. The project involves systematic replacement of existing lighting fixtures, with careful attention to code compliance, electrical safety, and proper installation techniques. The drawings include specific symbols, legends, and modification details for ceiling and light fixture changes, covering the entire S-Wing corridor across multiple floors. The documentation demonstrates a comprehensive approach to modernizing the building's lighting infrastructure while maintaining strict adherence to current electrical and safety standards.

View the file

Other files

File Type Posted
Pricing Sheet.docx DOCX document
25.10.08 S Wing Corridor Lighting - Specs IFB.pdf PDF
Introduction Page.docx DOCX document
Addendum-Q_A (1).docx DOCX document
Certifications.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

E. SALZBURG RD.

E. HOTCHKISS RD.

DELTA RD.

MIDLAND RD.

US-10

BAY CITY

SAGINAW

TO MIDLAND

S.

M

AC

KI

NA

W

R D.

7 M

ILE

R D.

SA

GI

NA

W

R

IV

ER

W

IL

LI

AM

A . K

IB

BE

A

SS

O

C

IA

TE

S, IN

C

E

N G

IN

E

E R

S

A R

C H

IT

E

C

TS

S

U R

V E

Y O

R S

PR

IN

TE

D:

SHEET

PROJ #:

DRAWN BY:

DES'D BY:

CHCK'D BY:

/8/

2:

:31 P

M

©2

7 - A

LL

R

IG

HT

S

RE

SE

RV

ED

. T

HI

S

DO

CU

ME

NT

A

ND

D

ES

IG

NS

P

OR

TR

AY

ED

W

IT

HI

N

AR

E

TH

E

PR

OP

ER

TY

O

F W

AK

, N

O

MO

DI

FI

CA

TI

ON

S

AN

D/

OR

T

RA

NS

FE

RS

O F

W

OR

K

AR

E

PE

RM

IT

TE

D

UN

LE

SS

G

RA

NT

ED

B

Y W

AK DELTA COLLEGE

UNIVERSITY CENTER MI 48710

1961 DELTA RD

S-WING CORRIDOR LIGHTING

25-0543-0153

B. KUSHION

B. KUSHION

E. MARTER

CO

VE

R

SH

EE

T

DE

LT

A

CO

LL

EG

E S-

W

IN

G

CO

RR

ID

OR

LI

GH

TI

NG

CS

UN

IV

ER

SI

TY

C

EN

TE

R

MI

WILLIAM A. KIBBE & ASSOCIATES, INC.

ENGINEERS | ARCHITECTS | SURVEYORS

PHONE:

EMAIL:

WEB:

PROJECT MANAGER

www.kibbe.com

PHONE:

EMAIL:

PROJECT DESIGNER

CODE AUTHORITY:

OWNER / CLIENT:

PHONE:

EMAIL:

DELTA COLLEGE

CONTACT INFORMATIONLOCATION MAP PROJECT INFORMATION

1961 DELTA RD

UNIVERSITY CENTER, MICHIGAN 48710

(989) 686-9000

ANTHONY KHALIL

PROJECT MANAGER/STAFF ARCHITECT

(989) 686-9407 anthonykhalil@delta.edu

SHEET INDEX

NU

MB

ER

TITLE 08

-2

8-

O W

NE

R

RE

VI

EW

-0

3-

O W

NE

R

RE

VI

EW

-0 8-

IS

SU

ED

F

OR

B

ID

S

GENERAL

CS COVER SHEET X X X

ELECTRICAL

E0.0 GENERAL NOTES X X X

E0.1 SPECIFICATIONS X

E1.0 S-WING LOWER LEVEL LIGHTING DEMOLITION PLAN X X X

E1.1 S-WING FIRST FLOOR LIGHTING DEMOLITION PLAN X X X

E1.2 S-WING SECOND FLOOR LIGHTING DEMOLITION PLAN X X X

E3.0 S-WING LOWER LEVEL LIGHTING PLAN X X X

E3.1 S-WING FIRST FLOOR LIGHTING PLAN X X X

E3.2 S-WING SECOND FLOOR LIGHTING PLAN X X X

E8.0 DETAILS X

ERIC MARTER

(989) 752-5000 emarter@kibbe.com

BRANDON KUSHION

(989) 752-5000 bkushion@kibbe.com

FRANKENLUST TOWNSHIP

2401 DELTA RD

BAY CITY, MI 48706

(989) 860-2219

LES LUPTOWSKI

BUILDING INSPECTOR

PHONE: (989) 239-0360

STATE OF MICHIGAN

BUREAU OF FIRE SERVICES (BFS)

611 W. OTTAWA ST., 4TH FLR

P.O. BOX 30700

LANSING, MI 48909

WWW.MICHIGAN.GOV/BFS

(517) 241-8847

BUILDING CODE COMPLIANCE

2021 MICHIGAN REHABILITATION CODE (MRC)

2021 MICIGAN BUILDING CODE (MBC)

2021 MICHIGAN PLUMBING CODE (MPC)

2021 MICHIGAN MECHANCIAL CODE (MMC)

2023 NATIONAL ELECTRIC CODE (NEC)

2015 INTERNATIONAL FIRE CODE (IFC)

2012 NFPA 101 LIFE SAFETY CODE (LSC)

NO

ST

AT

US

/ R

EV

IS

IO

NS

DA

TE

O W

NE

R

RE

VI

EW

-2 8-

O

W

NE

R

RE

VI

EW

-0

3-

IS

SU

ED

F

OR

B

ID

S

-0

8-

JB

TV

DO

C

R

GF

I C

C GFI

GF

I

GF

I

C

C GFI

PP

S

AD

A

A

##CD

AV

##CD

V

##CD

GF

I

US

B

C

DC

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE LATEST

ACCEPTED EDITION OF THE NATIONAL ELECTRICAL CODE (NEC) AND ALL

STATE AND LOCAL CODES.

COORDINATE THE INSTALLATION OF ALL EQUIPMENT REQUIRING

ELECTRICAL CONNECTIONS WITH ARCHITECTURAL AND MECHANICAL

PLANS, SPECIFICATIONS AND EQUIPMENT DRAWINGS. PROVIDE ALL

NECESSARY EQUIPMENT POWER AND CONTROL CONNECTIONS NOT

PROVIDED BY OTHERS WHETHER INDICATED ON THE DRAWINGS OR NOT.

UNLESS OTHERWISE NOTED, WHERE ELECTRICAL DEMOLITION WORK IS

SHOWN, REMOVE ALL CONDUCTOR AND EXPOSED CONDUITS FROM

EQUIPMENT OR OUTLET LOCATION BACK TO THE POWER SOURCE(S) FOR

THE CIRCUIT.

SEAL ALL WALL AND FLOOR PENETRATIONS TO MAINTAIN RATING.

BACK-TO-BACK OR THROUGH THE WALL BOXES SHALL NOT BE USED.

ALL LOW VOLTAGE CONDUCTORS SHALL BE STRANDED COPPER.

SPLICE CABLES OR CONDUCTORS IN OUTLET BOXES, DEVICE BOXES,

PULL BOXES, JUNCTION BOXES. DO NOT SPLICE CABLES OR

CONDUCTORS IN CONDUIT BODIES.

RECEPTACLES INDICATED AS GROUND FAULT CIRCUIT INTERRUPTER (GFI)

TYPE MUST BE GFI RECEPTACLE, NO FEED THROUGH.

BRANCH CIRCUITS FROM CIRCUIT BREAKER TYPE DISTRIBUTION

EQUIPMENT WHICH SUPPLY MOTOR LOADS THAT ARE LESS THAN 6.0 AMP

SHALL BE PROTECTED BY A 15 AMP CIRCUIT BREAKER.

FINAL CONNECTIONS TO ITEMS SUBJECT TO VIBRATION SHALL BE MADE

WITH LIQUID TIGHT FLEXIBLE METAL CONDUIT. LIQUID TIGHT FLEXIBLE

METAL CONDUIT SHALL NOT BE USED AS A GROUNDING CONDUCTOR.

PROVIDE A SEPARATE GREEN GROUNDING CONDUCTOR.

IN THE EVENT OF CONFLICTS BETWEEN THE REQUIREMENTS OF THE

DRAWINGS AND SPECIFICATIONS OR WITHIN THE DRAWINGS OR

SPECIFICATIONS, THE MORE STRINGENT REQUIREMENT SHALL BE

ASSUMED TO BE CORRECT. REFER UNCERTAINTIES IN REQUIREMENTS

TO THE ENGINEER FOR CLARIFICATION.

ALL BELOW GRADE LOCATIONS WITHIN BUILDINGS ARE DAMP LOCATIONS

UNLESS OTHERWISE NOTED.

120V AC CONTROL WIRING ASSOCIATED WITH MOTOR CONTROL CIRCUITS

MAY BE RUN IN THE SAME RACEWAY WITH MOTOR POWER WIRING FOR

CONSTANT SPEED MOTORS LESS THAN 30HP. FOR MOTORS 30HP AND

GREATER OR FOR MOTORS POWERED FROM VARIABLE FREQUENCY

CONTROLLERS, SEPARATE RACEWAYS SHALL BE USED FOR POWER AND

CONTROL CONDUCTORS.

120/240V CIRCUIT WIRING FOR ANY ROOM OR AREA MAY BE GROUPED

INTO RACEWAYS AS REQUIRED UNLESS SEPARATE RACEWAYS ARE

REQUIRED BY THE NEC. COMPLY WITH NEC REQUIREMENTS FOR

CONDUCTOR DERATING.

CONDUIT PENETRATIONS OF FLOORS, LOWER LEVEL EXTERIOR WALLS OR

WETWELL WALLS SHALL BE SLEEVED AND SEALED WITH LINKSEAL. SEE

DETAILS ON MECHANICAL DRAWINGS.

IF COMPLIANCE WITH TWO OR MORE DIFFERING STANDARDS,

REQUIREMENTS, DRAWINGS OR SPECIFICATIONS, OR ANY COMBINATION

THEREOF, IS SPECIFIED AND THESE ESTABLISH DIFFERENT OR

CONFLICTING REQUIREMENTS FOR MINIMUM QUANTITIES OR QUALITY

LEVELS, COMPLY WITH THE MOST STRINGENT REQUIREMENT. THE MOST

STRINGENT REQUIREMENT WILL BE THE BETTER QUALITY OR GREATER

QUANTITY OF WORK, AND WILL TYPICALLY BE THE MORE EXPENSIVE

OPTION. REFER UNCERTAINTIES AND REQUIREMENTS THAT ARE

DIFFERENT, BUT APPARENTLY EQUAL, TO ENGINEER FOR A DECISION

BEFORE PROCEEDING.

THE QUANTITY OR QUALITY LEVEL SHOWN OR SPECIFIED SHALL BE THE

MINIMUM PROVIDED OR PERFORMED. THE ACTUAL INSTALLATION MAY

COMPLY EXACTLY WITH THE MINIMUM QUANTITY OR QUALITY SPECIFIED,

OR IT MAY EXCEED THE MINIMUM WITHIN REASONABLE LIMITS. TO

COMPLY WITH THESE REQUIREMENTS, INDICATED NUMERIC VALUES ARE

MINIMUM OR MAXIMUM, AS APPROPRIATE, FOR THE CONTEXT OF

REQUIREMENTS. REFER UNCERTAINTIES TO ENGINEER FOR A DECISION

BEFORE PROCEEDING.

DESIGN DOCUMENTS MUST BE REPRODUCED IN THEIR ENTIRETY,

INCLUDING ALL PLANS, SPECIFICATIONS, AND FRONT END DOCUMENTS.

ONLY COMPLETE DOCUMENT SETS ARE TO BE DISTRIBUTED TO

SUBCONTRACTORS AND SUPPLIERS OF THE CONTRACTOR DURING

BIDDING OR CONSTRUCTION.

FAILURE TO REVIEW AND COMPLY WITH A FULL SET OF CONTRACT

DOCUMENTS WILL NOT BE ACCEPTED AS A VALID REASON FOR FAILURE

TO MEET THE REQUIREMENTS OF THE PLANS AND SPECIFICATIONS.

ALL ABOVE CEILING SYSTEMS AND COMPONENTS (INCLUDING BUT NOT

LIMITED TO MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION,

ETC.) SHALL BE COORDINATED SUCH THAT THE SYSTEMS ARE PROPERLY

INTEGRATED IN THE SPACE PROVIDED ABOVE CEILING AT THE CEILING

HEIGHTS NOTED. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR TO

COORDINATE PATHWAYS WITHIN THE SPACE PROVIDED. CEILING HEIGHTS

WILL NOT BE MODIFIED.

EQUIPMENT SHALL BE MOUNTED 6'-0" AWAY FROM HEAT PRODUCING

EQUIPMENT. U.N.O.

A.F.F. ABOVE FINISHED FLOOR

ALT ALTERNATE

AL ALUMINUM

AWG AMERICAN WIRE GAUGE

AMP OR A AMPERES

ATS AUTOMATIC TRANSFER

BLDG BUILDING

BMS BUILDING MANAGEMENT SYSTEM

CKT CIRCUIT

CB CIRCUIT BREAKER

C CONDUIT

CLG CEILING

CP CONTROL PANEL

CU COPPER

D DATA

DS DISCONNECT SWITCH

DWG DRAWING(S)

EA EACH

EMT ELECTRICAL METALLIC TUBING

EX EXISTING

EXT EXTERNAL

FIN. FLR. FINISH FLOOR

FACP FIRE ALARM CONTROL PANEL

FF FURNITURE FEED

FT FOOT, FEET

GRC GALVANIZED RIGID CONDUIT

GND GROUND

GFCI GROUND FAULT CIRCUIT

INTERUPPTER

GFI GROUND FAULT PROTECTION

HH HAND HOLE

HOA HAND-OFF-AUTO SELECTOR SWITCH

IU INDOOR UNIT

IMC INTERMEDIATE METAL CONDUIT

JB JUNCTION BOX

KVA KILO VOLT-AMPERES

KVAR KILO VOLT-AMPERES REACTIVE

LC LIGHTING CONTRACTOR

MCB MAIN CIRCUIT BREAKER

MDP MAIN DISTRIBUTOR PANEL

MLO MAIN LUGS ONLY

MSB MAIN SWITCH BOARD

MH MAN HOLE

MFR MANUFACTURER'S

MCC MOTOR CONTROL CENTER

MTD MOUNTED

NEC NATIONAL ELECTRIC CODE

NEMA NATIONAL ELECTRICAL

MANUFACTURER'S ASSOCIATION

N.L. NIGHT LIGHT

NC NORMALLY CLOSED CONTACT

NO NORMALLY OPEN CONTACT

N.T.S. NOT TO SCALE

OU OUTDOOR UNIT

O.D. OUTSIDE DIAMETER

OL OVERLOADS-THERMAL

PNL PANEL W/ INDICATION

Ø PHASE

PH PHASE

PC PHOTO-SWITCH

P POLE

PLC PROGRAMMABLE LOGIC CONTROLLER

PB PULL BOX

PTT PUSH-TO-TEST

RMC RIGID METAL COUNT

SPEC SPECIFICATION

SW SWITCH

SWD SWITCHING DUTY

TEL TELEPHONE

TYP TYPICAL

UL UNDERWRITERS LABORATORY

U.N.O. UNLESS NOTED OTHERWISE

VFC VARIABLE FREQUENCY CONTROLLER

VFD VARIABLE FREQUENCY DRIVE

V VOLT

W WATT

WP WEATHER PROOF

W WIRE

W/ WITH

XF/ XFMR TRANSFORMER

XXAF XX AMPERE FUSE

XXAS XX AMPERE SWITCH

XP X POLES

LUMINAIRE: WALL MOUNTED W/ TYPE

LUMINAIRE: RECESSED DOWNLIGHT OR PENDANT W/ TYPE, REFER

TO SCHEDULE

LUMINAIRE: SURFACE OR RECESSED W/ TYPE, REFER TO

SCHEDULE

LUMINAIRE: ON EMERGENCY, LIFE SAFETY, OR LOCAL LIGHTING

CIRCUIT W/ TYPE, REFER TO SCHEDULE

EXIT SIGN: CEILING MOUNTED W/ TYPE, SEE SCHEDULE

EXIT SIGN: WALL MOUNTED W/ TYPE, SEE SCHEDULE

EM LIGHTS: WALL MOUNTED UNO, REFER TO SCHEDULE

REMOTE HEADS: WALL MOUNTED, REFER TO SCHEDULE

TV CONNECTION: 96" TO TOP, COAX CONNECTION, UNO

VOICE/ DATA OUTLET: 18" TO TOP, UNO

VOICE/ DATA OUTLET: CEILING MOUNTED, UNO

VOICE/ DATA/ TV OUTLET: FLOOR MOUNTED, UNO

TELEPHONE: 18" TO TOP, UNO

DATA/ TELEPHONE: 18" TO TOP, UNO

CONTROLS: SPEAKER (SEE SCHEDULE)

CONTROLS: ADA DOOR CONTROL OPENER, COORDINATE

WITH DOOR REQUIREMENTS

CONTROLS: ADA DOOR CONTROL OPENER, COORDINATE

WITH SECURITY, AUTO AND MANUAL CONTROL

SECURITY: PAN - TILT - ZOOM CAMERA

SECURITY: PUSH BUTTON

SECURITY: CARD READER

SECURITY: DOOR CONTACT

FIRE: MANUAL PULL STATION, WALL MOUNTED, 48" AFF TO TOP

UNO

FIRE: AUDIBLE AND VISUAL ANNUNCIATION, WALL MOUNTED, 8'-0"

AFF TO TOP UNO

FIRE: VISUAL ANNUNCIATION, WALL MOUNTED, 8'-0" AFF TO TOP

UNO

FIRE: AUDIBLE ANNUNCIATION, WALL MOUNTED, 8'-0" AFF TO TOP

UNO

FIRE: AUDIBLE AND VISUAL ANNUNCIATION, CEILING MOUNTED

FIRE: VISUAL ANNUNCIATION, CEILING MOUNTED

FIRE: AUDIBLE ANNUNCIATION, CEILING MOUNTED

FIRE: SMOKE DETECTOR, CEILING

FIRE: HEAT DETECTOR, CEILING

FIRE: SMOKE AND HEAT DETECTOR

FIRE: DUCT SMOKE DETECTOR, CEILING, PROVIDED / INSTALLED

BY EC, MOUNTED BY MC, UNO

FIRE ALARM: REMOTE TEST STATION

FIRE: TAMPER SWITCH

FIRE: FLOW SWITCH

FIRE: MAGNETIC DOOR HOLD

FIRE: DOOR LOCK RELEASE

FIRE: PRESSURE SWITCH

DUPLEX RECEPTACLE, 18" A.F.F. TO TOP

DUPLEX RECEPTACLE GFI, 18" A.F.F. TO TOP

DUPLEX RECEPTACLE, CEILING MOUNTED

DUPLEX RECEPTACLE GFI, CEILING MOUNTED

DUPLEX RECEPTACLE USB, 18" A.F.F. TO TOP

DUPLEX RECEPTACLE, 6" ABOVE COUNTER

DUPLEX RECEPTACLE GFI, 6" ABOVE COUNTER

DUPLEX RECEPTACLE SWITCHED, 18" A.F.F. TO TOP

DUPLEX RECEPTACLE, FLOOR MOUNTED

DUPLEX RECEPTACLE GFI , FLOOR MOUNTED

SPECIALTY OUTLET, SEE DRAWINGS W/ MTG HT

QUAD RECEPTACLE, 18" A.F.F. TO TOP

QUAD RECEPTACLE GFI, 18" A.F.F. TO TOP

QUAD RECEPTACLE ONE DUPLEX SWITCHED, 18"

A.F.F. TO TOP

QUAD RECEPTACLE, CEILING MOUNTED

QUAD RECEPTACLE GFI, CEILING MOUNTED

MOTOR SWITCH

OVERHEAD DOOR 3-BUTTON SWITCH, OPEN-

CLOSE-STOP

SWITCH, SINGLE POLE, 48" A.F.F. TO TOP UNO

SWITCH, 3-POLE, 48" A.F.F. TO TOP UNO

SWITCH, 4-POLE, 48" A.F.F. TO TOP UNO

SWITCH, WALL BOX DIMMER, 48" A.F.F. TO TOP UNO

SWITCH, LOW VOLTAGE, 48" A.F.F. TO TOP UNO (VERIFY

W/ FIXTURE)

SWITCH, LOW VOLTAGE DIMMER, 48" A.F.F. TO TOP UNO

(VERIFY W/ FIXTURE)

SWITCH, FUSED: 125V, SINGLE POLE, DUAL ELEMENT

PLUG FUSE

SWITCH, KEYED, 48" A.F.F. TO TOP UNO

SWITCH, PILOT LIGHT, 48" A.F.F. TO TOP UNO

SWITCH, TIMER, 48" A.F.F. TO TOP

SWITCH, MULTI-TECH OCCUPANCY SENSOR, WALL

SWITCH, MULTI-TECH OCCUPANCY SENSOR, CEILING

SWITCH, EXTERIOR PHOTOCELL

POWER PACK FOR OCCUPANCY SENSORS

HOME RUN W/ DIRECTION

ELECTRICAL CIRCUIT

UNDERGROUND ELECTRICAL W/ INCDICATOR

SITE: LIGHT, POLE, AND BASE

TRANSFORMER W/ LABEL

DEVICE OR EQUIPMENT CONNECTION

A

A

POWER POLE

JUNCTION BOX

FURNITURE FEED

MOTOR

NON-FUSED DISCONNECT

COMBINATION MOTOR STARTER/ DISCONNECT

FUSED DISCONNECT

MANUAL MOTOR STARTER

MOTOR STARTER

SURFACE MOUNTED PANEL BOARD

RECESSED PANEL BOARD

OS

PC

PP

AV

V

A

SD

HD

S/H

DSD

TS

FS

DH

FR

#CD

#CD

P

PS

RT

E

UG

XF

D

LV

F

K

P

T

OS

SYMBOL DESCRIPTION

SYMBOL LEGEND

FF

LVD

M

W

IL

LI

AM

A . K

IB

BE

A

SS

O

C

IA

TE

S, IN

C

E

N G

IN

E

E R

S

A R

C H

IT

E

C

TS

S

U R

V E

Y O

R S

PR

IN

TE

D:

SHEET

PROJ #:

DRAWN BY:

DES'D BY:

CHCK'D BY:

/8/

2:

:32 P

M

25-0543-0153

B. KUSHION

B. KUSHION

E. MARTER

GE

NE

RA

L N

OT

ES

DE

LT

A

CO

LL

EG

E S-

W

IN

G

CO

RR

ID

OR

LI

GH

TI

NG

E0.0

©2

7 - A

LL

R

IG

HT

S

RE

SE

RV

ED

. T

HI

S

DO

CU

ME

NT

A

ND

D

ES

IG

NS

P

OR

TR

AY

ED

W

IT

HI

N

AR

E

TH

E

PR

OP

ER

TY

O

F W

AK

, N

O

MO

DI

FI

CA

TI

ON

S

AN

D/

OR

T

RA

NS

FE

RS

O F

W

OR

K

AR

E

PE

RM

IT

TE

D

UN

LE

SS

G

RA

NT

ED

B

Y W

AK

UN

IV

ER

SI

TY

C

EN

TE

R

MI

GENERAL NOTESABBREVIATIONSLIGHTING FIXTURE SCHEDULE

TYPE

NAME

LAMP

DESCRIPTION

BASIS OF DESIGN

COMMENTSTYPE VA VOLT MANUFACTURER CAT. NO.

A LED 42.2 VA 120 V 1X4 LED FLAT PANEL, 3500K, 5000 LUMENS, 80CRI, 0-10V DIMMING LITHONIA LIGHTING CPX 1X4 5000LM 80CRI 35K

SWL MIN1 EZT MVOLT

B LED 17.2 VA 120 V 1X4 LED FLAT PANEL, 3500K, 2000 LUMENS, 80CRI, 0-10V DIMMING LITHONIA LIGHTING CPX 1X4 2000LM 80CRI 35K

SWL MIN1 EZT MVOLT

PROVIDE WITH ACCESSORY DGA14

FOR MOUNTING IN GYP CEILING

C LED 55.4 VA 120 V 1X4 LED FLAT PANEL, 3500K, 6000 LUMENS, 80CRI, 0-10V DIMMING LITHONIA LIGHTING CPX 1X4 6000LM 80CRI 35K

SWL MIN1 EZT MVOLT

D LED 24.6 VA 120 V 2X4 LED FLAT PANEL, 3500K, 3000 LUMENS, 80CRI, 0-10V DIMMING LITHONIA LIGHTING CPX 2X4 3000LM 80CRI 35K

SWL MIN1 EZT MVOLT

PROVIDE WITH ACCESSORY DGA24

FOR MOUNTING IN GYP CEILING

F LED 28.5 VA 120 V 8' LED LINEAR LIGHT, PENDANT MOUNT, 20% UPLIGHT, 80%

DOWNLIGHT, HIGH OUTPUT, SINGLE CIRCUIT, 3500K

FINELITE S12 LED ID - DCO - 8' - 2E - H -

835 - 20U80D - 91 - 120V -

FC-10% - SC - FA - FE - SW - C4

NO

ST

AT

US

/ R

EV

IS

IO

NS

DA

TE

O W

NE

R

RE

VI

EW

-2 8-

O

W

NE

R

RE

VI

EW

-0

3-

IS

SU

ED

F

OR

B

ID

S

-0

A.

A.

1.

2.

3.

A.

B.

C.

D.

E.

F.

A.

1.

2.

3.

4.

B.

C.

A.

B.

C.

A.

1.

2.

3.

4.

5.

6.

7.

8.

9.

A.

B.

C.

A.

B.

C.

D.

E.

F.

G.

A.

B.

C.

A.

1.

2.

3.

4.

B.

C.

D.

1.

2.

3.

A.

A.

DIVISION 26000 - ELECTRICAL SPECIFICATIONS

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 1

SPECIFICATION SECTIONS, APPLY TO THIS SECTION.

1.2 SUBMITTALS

PRODUCT DATA FOR:

WIRING DEVICES

LIGHTING FIXTURES

LIGHTING CONTROLS

1.3 QUALITY ASSURANCE

ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, ARTICLE 100, BY A TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, AND MARKED FOR INTENDED USE.

COMPLY WITH UL 467 FOR GROUNDING AND BONDING MATERIALS AND EQUIPMENT.

COMPLY WITH NFPA 70

COMPLY WITH NECA 1, INCLUDING THE MOUNTING HEIGHTS LISTED IN THAT STANDARD, UNLESS OTHERWISE NOTED.

COMPLY WITH APPLICABLE PORTIONS OF NECA1, NEMA PB 1.1, AND NEMA PB 2.1 FOR INSTALLATION OF ENCLOSED SWITCHES AND

CIRCUIT BREAKERS.

SOURCE LIMITATIONS: OBTAIN EACH TYPE OF PRODUCT, EQUIPMENT, AND WIRING DEVICES AND ASSOCIATED WALL PLATE THROUGH ONE SOURCE FROM A SINGLE MANUFACTURER. SO FAR AS THEY ARE AVAILABLE, OBTAIN ALL PRODUCTS, EQUIPMENT, AND WIRING

DEVICES AND ASSOCIATED WALL PLATES FROM A SINGLE MANUFACTURER AND ONE SOURCE.

1.4 COORDINATION

COORDINATE ARRANGEMENT, MOUNTING, AND SUPPORT OF ELECTRICAL EQUIPMENT:

TO ALLOW MAXIMUM POSSIBLE HEADROOM UNLESS SPECIFIC MOUNTING HEIGHTS THAT REDUCE HEADROOM ARE INDICATED.

TO PROVIDE FOR EASE OF DISCONNECTING THE EQUIPMENT WITH MINIMUM INTERFERENCE TO OTHER INSTALLATIONS.

TO ALLOW RIGHT OF WAY FOR PIPING AND CONDUIT INSTALLED AT REQUIRED SLOPE.

SO CONNECTING RACEWAYS, CABLES, WIREWAYS, CABLE TRAYS, AND BUSWAYS WILL BE CLEAR OF OBSTRUCTIONS AND OF THE

WORKING AND ACCESS SPACE OF OTHER EQUIPMENT.

COORDINATE IDENTIFICATION NAMES, ABBREVIATIONS, COLORS, AND OTHER FEATURES WITH REQUIREMENTS IN THE CONTRACT DOCUMENTS, SHOP DRAWINGS, MANUFACTURER'S WIRING DIAGRAMS, AND THE OPERATION AND MAINTENANCE MANUAL, AND WITH THOSE REQUIRED BY CODES, STANDARDS, AND 29 CFR 1910.145. USE CONSISTENT DESIGNATIONS THROUGHOUT PROJECT.

RECEPTACLES FOR OWNER-FURNISHED EQUIPMENT: MATCH PLUG CONFIGURATIONS.

PART 2 - PRODUCTS

2.1 GROUNDING PRODUCTS

BONDING CONDUCTOR: NO. 6 AWG INSULATED COPPER, STRANDED CONDUCTOR.

WELDED CONNECTORS: EXOTHERMIC-WELDING KITS OF TYPES RECOMMENDED BY KIT MANUFACTURER FOR MATERIALS BEING

JOINED AND INSTALLATION CONDITIONS.

GROUND RODS: COPPER-CLAD STEEL 3/4 INCH BY 10 FEET.

2.2 RACEWAYS AND WIREWAYS

RACEWAY MATERIALS:

RIGID STEEL CONDUIT (RMC): ANSI C80.1.

EMT: ANSI C80.3.

LFMC: FLEXIBLE STEEL CONDUIT WITH PVC JACKET.

FITTINGS FOR CONDUIT (INCLUDING ALL TYPES AND FLEXIBLE AND LIQUIDTIGHT), EMT, AND CABLE. NEMA FB 1: LISTED FOR TYPE AND SIZE RACEWAY WITH WHICH USED, AND FOR APPLICATION AND ENVIRONMENT IN WHICH INSTALLED.

SURFACE RACEWAY: WIREMOLD SERIES 500/700 ONE PIECE RACEWAY

METAL WIREWAYS DESCRIPTION: SHEET METAL SIZED AND SHAPED AS INDICATED, NEMA 250, TYPE 1 OR 3R, UNLESS OTHERWISE

INDICATED. WIREWAY COVERS: SCREW-COVER TYPE OR AS INDICATED.

SHEET METAL OUTLET AND DEVICE BOXES: NEMA OS 1.

SMALL SHEET METAL PULL AND JUNCTION BOXES: NEMA OS 1.

CABINETS:

NEMA 250, TYPE 1, GALVANIZED-STEEL BOX WITH REMOVABLE INTERIOR PANEL AND REMOVABLE.

HINGED DOOR IN FRONT COVER WITH FLUSH LATCH AND CONCEALED HINGE.

KEY LATCH TO MATCH PANELBOARDS.

2.3 CABLES AND WIRING MATERIALS

CONDUCTOR INSULATION: COMPLY WITH NEMA WC 70 FOR TYPES THW AND THHN-THWN.

MULTICONDUCTOR CABLE: COMPLY WITH NEMA WC 70 FOR METAL-CLAD CABLE, TYPE MC WITH GROUND WIRE.

FEEDERS: COPPER, STRANDED

BRANCH CIRCUITS: COPPER, STRANDED, MINIMUM 12 AWG.

EXPOSED OR CONCEALED FEEDERS AND BRANCH CIRCUITS: TYPE THHN-THWN, SINGLE CONDUCTORS IN RACEWAY.

CLASS 1 CONTROL CIRCUITS: TYPE THHN-THWN, IN RACEWAY.

CLASS 2 CONTROL CIRCUITS: TYPE THHN-THWN, IN RACEWAY, OR POWER-LIMITED CABLE, CONCEALED IN BUILDING FINISHES.

2.4 IDENTIFICATION MATERIALS

COLOR-CODING CONDUCTOR TAPE: COLORED, SELF-ADHESIVE VINYL-TAPE NOT LESS THAN 3 MILS THICK BY 1 TO 2 INCHES WIDE.

MARKER TAPES: VINYL OR VINYL-CLOTH, SELF-ADHESIVE WRAPAROUND TYPE, WITH CIRCUIT IDENTIFICATION LEGEND MACHINE

PRINTED BY THERMAL TRANSFER OR EQUIVALENT PROCESS.

SELF-ADHESIVE, ENGRAVED, LAMINATED ACRYLIC OR MELAMINE LABEL. ADHESIVE BACKED, WITH WHITE LETTERS ON A DARK-GRAY

BACKGROUND. MINIMUM LETTER HEIGHT SHALL BE 3/8 INCH.

2.5 WIRING DEVICES

PROVIDE PRODUCTS BY ONE OF THE FOLLOWING MANUFACTURERS:

COOPER WIRING DEVICES: A DIVISION OF COOPER INDUSTRIES, INC.

HUBBELL INCORPORATED: WIRING DEVICE-KELLEMS.

LEVITON MFG. COMPANY, INC.

PASS & SEYMOUR/LEGRAND: WIRING DEVICES & ACCESSORIES.

GFCI DUPLEX RECEPTACLES: STRAIGHT BLADE, FEED-THROUGH TYPE. COMPLY WITH NEMA WD 1, NEMA WD 6, UL 498, AND UL 943, CLASS A, AND INCLUDE INDICATOR LIGHT THAT IS LIGHTED WHEN DEVICE IS TRIPPED.

SNAP SWITCHES: COMPLY WITH NEMA WD 1 AND UL 20, 120/277V, 20A.

WALL PLATES: SINGLE AND COMBINATION TYPES TO MATCH CORRESPONDING WIRING DEVICES.

PLATE-SECURING SCREWS: METAL WITH HEAD COLOR TO MATCH PLATE FINISH.

MATERIAL: SMOOTH, HIGH-IMPACT THERMOPLASTIC.

WET OR DAMP-LOCATION, WEATHERPROOF COVER PLATES: NEMA 250, COMPLYING WITH TYPE 3R WEATHER-RESISTANT, DIE-CAST

ALUMINUM WITH LOCKABLE COVER.

2.6 LIGHTING FIXTURES

SEE LIGHTING FIXTURE SCHEDULE ON THE DRAWINGS FOR PRODUCT SPECIFICATIONS.

2.7 LIGHTING CONTROLS

BASIS OF DESIGN IS ACUITY BRANDS. ALTERNATES MUST BE REVIEWED FOR APPROVAL DURING BIDDING. SEE REQUIREMENTS OF THE

DRAWINGS.

A.

B.

A.

B.

C.

A.

B.

1.

A.

2.

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

C.

D.

E.

F.

G.

H.

1.

2.

A.

B.

C.

3.

A.

B.

C.

4.

A.

B.

5.

A.

B.

C.

D.

A.

B.

C.

1.

2.

3.

4.

5.

D.

E.

1.

F.

G.

H.

I.

J.

K.

L.

M.

N.

1.

A.

B.

C.

D.

E.

F.

G.

H.

I.

J.

1.

K.

L.

A.

B.

A.

1.

2.

B.

1.

C.

PART 3 - EXECUTION

3.1 COMMON REQUIREMENTS FOR ELECTRICAL INSTALLATION

EQUIPMENT: INSTALL TO FACILITATE SERVICE, MAINTENANCE, AND REPAIR OR REPLACEMENT OF COMPONENTS OF BOTH ELECTRICAL EQUIPMENT AND OTHER NEARBY INSTALLATIONS. CONNECT IN SUCH A WAY AS TO FACILITATE FUTURE DISCONNECTING WITH MINIMUM

INTERFERENCE WITH OTHER ITEMS IN THE VICINITY.

RIGHT OF WAY: GIVE TO PIPING SYSTEMS INSTALLED AT A REQUIRED SLOPE.

3.2 GROUNDING APPLICATIONS

INSTALL INSULATED EQUIPMENT GROUNDING CONDUCTORS WITH ALL FEEDERS AND BRANCH CIRCUITS. INSULATION SHALL BE RATED AT 600V

OR AS APPROVED BY AUTHORITY HAVING JURISDICTION.

CONDUCTORS: INSTALL SOLID CONDUCTOR FOR NO. 10 AWG AND SMALLER, AND STRANDED CONDUCTORS FOR NO. 8 AWG AND LARGER, UNLESS OTHERWISE INDICATED.

METAL POLES FOR SIGNS SUPPORTING OUTDOOR LIGHTING FIXTURES: INSTALL GROUNDING ELECTRODE AND A SEPARATE INSULATED EQUIPMENT GROUNDING CONDUCTOR IN ADDITION TO GROUNDING CONDUCTOR INSTALLED WITH BRANCH-CIRCUIT CONDUCTORS.

3.3 APPLICATION OF IDENTIFICATION SYSTEMS

BRANCH-CIRCUIT CONDUCTOR IDENTIFICATION: WHERE THERE ARE CONDUCTORS FOR MORE THAN THREE BRANCH CIRCUITS IN SAME JUNCTION OR PULL BOX, USE COLOR-CODING CONDUCTOR TAPE. IDENTIFY EACH UNDERGROUND CONDUCTOR ACCORDING TO SOURCE AND

CIRCUIT NUMBER.

EQUIPMENT IDENTIFICATION LABELS: ON EACH UNIT OF EQUIPMENT, INSTALL UNIQUE DESIGNATION LABEL THAT IS CONSISTENT WITH WIRING DIAGRAMS, SCHEDULES, AND OPERATION AND MAINTENANCE MANUAL. APPLY LABELS TO DISCONNECT SWITCHES AND PROTECTION EQUIPMENT, CENTRAL OR SYSTEM. SYSTEMS INCLUDE POWER, LIGHTING, CONTROL, COMMUNICATION, SIGNAL, MONITORING, AND ALARM

SYSTEMS UNLESS EQUIPMENT IS PROVIDED WITH ITS OWN IDENTIFICATION.

LABELING INSTRUCTIONS:

INDOOR EQUIPMENT: ADHESIVE FIELD LABEL. UNLESS OTHERWISE INDICATED, PROVIDE A SINGLE LINE OF TEXT WITH 1/2-INCH-HIGH LETTERS ON 1-1/2-INCH-HIGH LABEL. WHERE 2 LINES OF TEXT ARE REQUIRED, USE LABELS 2 INCHES HIGH.

EQUIPMENT TO BE LABELED:

PANELBOARDS, ELECTRICAL CABINETS, AND ENCLOSURES.

ACCESS DOORS AND PANELS FOR CONCEALED ELECTRICAL ITEMS.

TRANSFORMERS.

DISCONNECT SWITCHES.

ENCLOSED CIRCUIT BREAKERS.

MOTOR STARTERS.

PUSH-BUTTON STATIONS.

CONTACTORS.

REMOTE-CONTROLLED SWITCHES, DIMMER MODULES, AND CONTROL DEVICES.

LIGHTING CONTROL EQUIPMENT.

VERIFY IDENTITY OF EACH ITEM BEFORE INSTALLING IDENTIFICATION PRODUCTS.

LOCATION: INSTALL IDENTIFICATION MATERIALS AND DEVICES AT LOCATIONS FOR MOST CONVENIENT VIEWING WITHOUT INTERFERENCE WITH

OPERATION AND MAINTENANCE OF EQUIPMENT.

APPLY IDENTIFICATION DEVICES TO SURFACES THAT REQUIRE FINISH AFTER COMPLETING FINISH WORK.

SELF-ADHESIVE IDENTIFICATION PRODUCTS: CLEAN SURFACES BEFORE APPLICATION, USING MATERIALS AND METHODS RECOMMENDED BY

MANUFACTURER OF IDENTIFICATION DEVICE.

SYSTEM IDENTIFICATION COLOR BANDING FOR RACEWAYS AND CABLES: EACH COLOR BAND SHALL COMPLETELY ENCIRCLE CABLE OR CONDUIT.

PLACE ADJACENT BANDS OF TWO-COLOR MARKINGS IN CONTACT, SIDE BY SIDE. LOCATE BANDS AT CHANGES IN DIRECTION, AT PENETRATIONS OF WALLS AND FLOORS, AT 50-FOOT MAXIMUM INTERVALS IN STRAIGHT RUNS, AND AT 25-FOOT MAXIMUM INTERVALS IN CONGESTED AREAS.

COLOR-CODING FOR PHASE AND VOLTAGE LEVEL IDENTIFICATION, 600V AND LESS: USE THE COLORS LISTED BELOW FOR UNGROUNDED

SERVICE, FEEDER, AND BRANCH-CIRCUIT CONDUCTORS.

COLOR SHALL BE FIELD APPLIED FOR CONDUCTORS OVER NO. 10 AWG.

COLORS FOR 480/277V CIRCUITS:

PHASE A: BROWN

PHASE B: ORANGE

PHASE C: YELLOW

COLORS FOR 120/208V CIRCUITS:

PHASE A: BLACK

PHASE B: RED

PHASE C: BLUE

COLORS FOR 120/240V CIRCUITS:

PHASE A: BLACK

PHASE B: RED

FIELD-APPLIED, COLOR-CODING CONDUCTOR TAPE: APPLY IN HALF-LAPPED TURNS FOR A MINIMUM DISTANCE OF 6 INCHES FROM TERMINAL POINTS AND IN BOXES WHERE SPLICES OR TAPS ARE MADE. APPLY LAST TWO TURNS OF TAPE WITH NO TENSION TO PREVENT POSSIBLE

UNWINDING. LOCATE BANDS TO AVOID OBSCURING FACTORY CABLE MARKINGS.

3.4 INSTALLATION OF POWER CONDUCTORS AND CABLES

CONCEAL CABLES IN FINISHED WALLS, CEILINGS, AND FLOORS, UNLESS OTHERWISE INDICATED.

USE MANUFACTURER-APPROVED PULLING COMPOUND OR LUBRICANT WHERE NECESSARY. COMPOUND USED MUST NOT DETERIORATE CONDUCTOR OR INSULATION. DO NOT EXCEED MANUFACTURER'S RECOMMENDED MAXIMUM PULLING TENSIONS AND SIDEWALL PRESSURE

VALUES.

USING PULLING MEANS, INCLUDING FISH TABLE, CABLE, ROPE, AND BASKET-WEAVE WIRE/CABLE GRIPS, THAT WILL NOT DAMAGE CABLES OR

RACEWAY.

WIRING AT OUTLETS: INSTALL CONDUCTOR AT EACH OUTLET, WITH AT LEAST 12 INCHES OF SLACK.

3.5 RACEWAY INSTALLATION AND APPLICATION

COMPLY WITH NECA 1 FOR INSTALLATION REQUIREMENTS APPLICABLE TO PRODUCTS SPECIFIED IN PART 2 EXCEPT WHERE REQUIREMENTS ON

DRAWINGS OR IN THIS ARTICLE ARE STRICTER.

SUPPORT RACEWAYS PER NEC - NFPA-70.

COMPLY WITH THE FOLLOWING INDOOR APPLICATIONS, UNLESS OTHERWISE INDICATED:

EXPOSED ON ACOUSTICAL BLOCK: METAL WIREMOLD.

EXPOSED, NOT SUBJECT TO PHYSICAL DAMAGE: EMT ABOVE 48".

CONCEALED IN CEILINGS AND INTERIOR WALLS AND PARTITIONS: EMT.

CONNECTION TO VIBRATING EQUIPMENT (INCLUDING TRANSFORMERS AND HYDRAULIC, PNEUMATIC, ELECTRIC SOLENOID, OR MOTOR-

DRIVEN EQUIPMENT): LFMC.

DAMP OR WET LOCATIONS: RIGID STEEL CONDUIT.

MINIMUM RACEWAY SIZE: 3/4-INCH TRADE SIZE.

RACEWAY FITTINGS: COMPATIBLE WITH RACEWAYS AND SUITABLE FOR USE AND LOCATION.

RIGID AND INTERMEDIATE STEEL CONDUIT: USE THREADED RIGID STEEL CONDUIT FITTINGS, UNLESS OTHERWISE INDICATED.

COMPLETE RACEWAY INSTALLATION BEFORE STARTING CONDUCTOR INSTALLATION.

ARRANGE STUB-UPS SO CURVED PORTIONS OF BENDS ARE NOT VISIBLE ABOVE THE FINISHED SLAB.

INSTALL NO MORE THAN THE EQUIVALENT OF THREE 90-DEGREE BENDS IN ANY CONDUIT RUN EXCEPT FOR COMMUNICATIONS CONDUITS, FOR

WHICH FEWER BENDS ARE ALLOWED.

CONCEAL CONDUIT AND EMT WITHIN FINISHED WALLS, CEILINGS, AND FLOORS, UNLESS OTHERWISE INDICATED.

RACEWAYS EMBEDDED IN SLABS: NOT ALLOWED.

THREADED CONDUIT JOINTS, EXPOSED TO WET, DAMP, CORROSIVE, OR OUTDOOR CONDITIONS: APPLY LISTED COMPOUND TO THREADS OF RACEWAY AND FITTINGS BEFORE MAKING UP JOINTS. FOLLOW COMPOUND MANUFACTURER'S WRITTEN INSTRUCTIONS.

RACEWAY TERMINATIONS AT LOCATIONS SUBJECT TO MOISTURE OR VIBRATION: USE INSULATING BUSHINGS TO PROTECT CONDUCTORS, INCLUDING CONDUCTORS SMALLER THAN NO. 4 AWG.

INSTALL PULL WIRES IN EMPTY RACEWAYS. USE POLYPROPYLENE OR MONOFILAMENT PLASTIC LINE WITH NOT LESS THAN 200-LB TENSILE

STRENGTH. LEAVE AT LEAST 12 INCHES OF SLACK AT EACH END OF PULL WIRE.

FLEXIBLE CONDUIT CONNECTIONS: USE MAXIMUM OF 72 INCHES OF FLEXIBLE CONDUIT FOR RECESSED AND SEMI-RECESSED LIGHTING FIXTURES, EQUIPMENT SUBJECT TO VIBRATION, NOISE TRANSMISSION, OR MOVEMENT; AND FOR TRANSFORMERS AND MOTORS.

USE LFMC IN DAMP OR WET LOCATIONS SUBJECT TO SEVERE PHYSICAL DAMAGE.

3.6 WIRING DEVICE INSTALLATION

REPLACE ALL DEVICES THAT HAVE BEEN IN TEMPORARY USE DURING CONSTRUCTION OR THAT SHOW SIGNS THAT THEY WERE INSTALLED

BEFORE BUILDING FINISHING OPERATIONS WERE COMPLETE.

KEEP EACH WIRING DEVICE IN ITS PACKAGE OR OTHERWISE PROTECTED UNTIL IT IS TIME TO CONNECT CONDUCTORS.

DO NOT REMOVE SURFACE PROTECTION, SUCH AS PLASTIC FILM AND SMUDGE COVERS, UNTIL THE LAST POSSIBLE MOMENT.

CONNECT DEVICES TO BRANCH CIRCUITS USING PIGTAILS THAT ARE NOT LESS THAN 6 INCHES IN LENGTH.

WHEN THERE IS A CHOICE, USE SIDE WIRING WITH BINDING-HEAD SCREW TERMINALS. WRAP SOLID CONDUCTOR TIGHTLY CLOCKWISE, 2/3 TO 3/4

OF THE WAY AROUND TERMINAL SCREW.

USE A TORQUE SCREWDRIVER WHEN A TORQUE IS RECOMMENDED OR REQUIRED BY THE MANUFACTURER.

WHEN CONDUCTORS LARGER THAN NO. 12 AWG ARE INSTALLED ON 15-A OR 20-A CIRCUITS, SPLICE NO. 12 PIGTAILS FOR DEVICE CONNECTIONS.

TIGHTEN UNUSED TERMINAL SCREWS ON THE DEVICE.

WHEN MOUNTING INTO METAL BOXES, REMOVE THE FIBER OR PLASTIC WASHERS USED TO HOLD DEVICE MOUNTING SCREWS IN YOKES, ALLOWING METAL-TO-METAL CONTACT.

RECEPTACLE ORIENTATION:

INSTALL GROUND PIN OF VERTICALLY MOUNTED RECEPTACLES UP, AND ON HORIZONTALLY MOUNTED RECEPTACLES TO THE RIGHT.

DEVICE PLATES: DO NOT USE OVERSIZED OR EXTRA-DEEP PLATES. REPAIR WALL FINISHES AND REMOUNT OUTLET BOXES WHEN STANDARD

DEVICE PLATES DO NOT FIT FLUSH OR DO NOT COVER ROUGH WALL OPENING.

ARRANGEMENT OF DEVICES: UNLESS OTHERWISE INDICATED, MOUNT FLUSH, WITH LONG DIMENSION VERTICAL AND WITH GROUNDING TERMINAL OF RECEPTACLES ON TOP. GROUP ADJACENT SWITCHES UNDER SINGLE, MULTIGANG WALL PLATES.

3.7 LIGHTING CONTROLS

CONDUCT PRE-INSTALLATION MEETING WITH THE SUPPLIER, PROGRAMMER, INSTALLER, AND OWNER TO REVIEW THE SYSTEM.

PERFORM POST VISIT FOR PROGRAMMING

3.8 FIELD QUALITY CONTROL

PREPARE FOR ACCEPTANCE TESTS AS FOLLOWS:

TEST INSULATION RESISTANCE FOR EACH PANELBOARD BUS, COMPONENT, CONNECTING SUPPLY, FEEDER, AND CONTROL CIRCUIT.

TEST CONTINUITY OF EACH CIRCUIT.

PERFORM THE FOLLOWING FIELD TESTS AND INSPECTIONS AND PREPARE TEST REPORTS:

CORRECT MALFUNCTIONING UNITS ON-SITE, WHERE POSSIBLE, AND RETEST TO DEMONSTRATE COMPLIANCE; OTHERWISE, REPLACE WITH

NEW UNITS AND RETEST.

PROVIDE OPERATION AND MAINTENANCE MANUALS FOR ALL EQUIPMENT. INCLUDE WARRANTY AND REPLACEMENT PART LIST.

W

IL

LI

AM

A . K

IB

BE

A

SS

O

C

IA

TE

S, IN

C

E

N G

IN

E

E R

S

A R

C H

IT

E

C

TS

S

U R

V E

Y O

R S

PR

IN

TE

D:

SHEET

PROJ #:

DRAWN BY:

DES'D BY:

CHCK'D BY:

/8/

2:

:32 P

M

25-0543-0153

B. KUSHION

B. KUSHION

E. MARTER

SP

EC

IF

IC

AT

IO

NS

DE

LT

A

CO

LL

EG

E

S- W

IN

G

CO

RR

ID

OR

LI

GH

TI

NG

E0.1

©2

7 - A

LL

R

IG

HT

S

RE

SE

RV

ED

. T

HI

S

DO

CU

ME

NT

A

ND

D

ES

IG

NS

P

OR

TR

AY

ED

W

IT

HI

N

AR

E

TH

E

PR

OP

ER

TY

O

F W

AK

, N

O

MO

DI

FI

CA

TI

ON

S

AN

D/

OR

T

RA

NS

FE

RS

O F

W

OR

K

AR

E

PE

RM

IT

TE

D

UN

LE

SS

G

RA

NT

ED

B

Y W

AK

UN

IV

ER

SI

TY

C

EN

TE

R

MI

NO

ST

AT

US

/ R

EV

IS

IO

NS

DA

TE

IS

SU

ED

F

OR

B

ID

S

-0

8-

A.

1.

2.

3.

4.

5.

6.

7.

8.

9.

B.

1.

2.

3.

4.

5.

C.

1.

2.

3.

4.

D.

A.

B.

C.

A.

1.

2.

3.

B.

C.

024119 SELECTIVE DEMOLITION (CONT)

3.4 SELECTIVE DEMOLITION, GENERAL

GENERAL: DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT

REQUIRED BY NEW CONSTRUCTION AND AS INDICATED. USE METHODS REQUIRED TO

COMPLETE THE WORK WITHIN LIMITATIONS OF GOVERNING REGULATIONS AND AS

FOLLOWS:

PROCEED WITH SELECTIVE DEMOLITION SYSTEMATICALLY, FROM HIGHER TO

LOWER LEVEL.

NEATLY CUT OPENINGS AND HOLES PLUMB, SQUARE, AND TRUE TO

DIMENSIONS REQUIRED. USE CUTTING METHODS LEAST LIKELY TO DAMAGE

CONSTRUCTION TO REMAIN OR ADJOINING CONSTRUCTION. USE HAND TOOLS

OR SMALL POWER TOOLS DESIGNED FOR SAWING OR GRINDING, NOT

HAMMERING AND CHOPPING, TO MINIMIZE DISTURBANCE OF ADJACENT

SURFACES.

CUT OR DRILL FROM THE EXPOSED OR FINISHED SIDE INTO CONCEALED

SURFACES TO AVOID MARRING EXISTING FINISHED SURFACES.

DO NOT USE CUTTING TORCHES UNTIL WORK AREA IS CLEARED OF

FLAMMABLE MATERIALS. AT CONCEALED SPACES, SUCH AS DUCT AND PIPE

INTERIORS, VERIFY CONDITION AND CONTENTS OF HIDDEN SPACE BEFORE

STARTING FLAME-CUTTING OPERATIONS. MAINTAIN FIRE WATCH AND

PORTABLE FIRE-SUPPRESSION DEVICES DURING FLAME-CUTTING

OPERATIONS.

MAINTAIN ADEQUATE VENTILATION WHEN USING CUTTING TORCHES.

REMOVE DECAYED, VERMIN-INFESTED, OR OTHERWISE DANGEROUS OR

UNSUITABLE MATERIALS AND PROMPTLY DISPOSE OF OFF-SITE.

REMOVE STRUCTURAL FRAMING MEMBERS AND LOWER TO GROUND BY

METHOD SUITABLE TO AVOID FREE FALL AND TO PREVENT GROUND IMPACT

OR DUST GENERATION.

LOCATE SELECTIVE DEMOLITION EQUIPMENT AND REMOVE DEBRIS AND

MATERIALS SO AS NOT TO IMPOSE EXCESSIVE LOADS ON SUPPORTING

WALLS, FLOORS, OR FRAMING.

DISPOSE OF DEMOLISHED ITEMS AND MATERIALS PROMPTLY. SITE ACCESS

AND TEMPORARY CONTROLS: CONDUCT SELECTIVE DEMOLITION AND DEBRIS-

REMOVAL OPERATIONS TO ENSURE MINIMUM INTERFERENCE WITH ROADS,

STREETS, WALKS, WALKWAYS, AND OTHER ADJACENT OCCUPIED AND USED

FACILITIES.

REMOVED AND SALVAGED ITEMS:

CLEAN SALVAGED ITEMS.

PACK OR CRATE ITEMS AFTER CLEANING. IDENTIFY CONTENTS OF

CONTAINERS.

STORE ITEMS IN A SECURE AREA UNTIL DELIVERY TO OWNER.

TRANSPORT ITEMS TO OWNER'S STORAGE AREA ON-SITE.

PROTECT ITEMS FROM DAMAGE DURING TRANSPORT AND STORAGE.

REMOVED AND REINSTALLED ITEMS:

CLEAN AND REPAIR ITEMS TO FUNCTIONAL CONDITION ADEQUATE FOR

INTENDED REUSE.

PACK OR CRATE ITEMS AFTER CLEANING AND REPAIRING. IDENTIFY

CONTENTS OF CONTAINERS.

PROTECT ITEMS FROM DAMAGE DURING TRANSPORT AND STORAGE.

REINSTALL ITEMS IN LOCATIONS INDICATED. COMPLY WITH INSTALLATION

REQUIREMENTS FOR NEW MATERIALS AND EQUIPMENT. PROVIDE

CONNECTIONS, SUPPORTS, AND MISCELLANEOUS MATERIALS NECESSARY TO

MAKE ITEM FUNCTIONAL FOR USE INDICATED.

EXISTING ITEMS TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN

AGAINST DAMAGE AND SOILING DURING SELECTIVE DEMOLITION. WHEN PERMITTED

BY ARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE, PROTECTED STORAGE

LOCATION DURING SELECTIVE DEMOLITION , CLEANED AND REINSTALLED IN THEIR

ORIGINAL LOCATIONS AFTER SELECTIVE DEMOLITION OPERATIONS ARE COMPLETE.

3.5 SELECTIVE DEMOLITION PROCEDURES FOR SPECIFIC MATERIALS

CONCRETE SLABS-ON-GRADE: SAW-CUT PERIMETER OF AREA TO BE DEMOLISHED,

THEN BREAK UP AND REMOVE.

CONCRETE: DEMOLISH IN SECTIONS. CUT CONCRETE FULL DEPTH AT JUNCTURES

WITH CONSTRUCTION TO REMAIN AND AT REGULAR INTERVALS USING POWER-

DRIVEN SAW, THEN REMOVE CONCRETE BETWEEN SAW CUTS.

MASONRY: DEMOLISH IN SMALL SECTIONS. CUT MASONRY AT JUNCTURES WITH

CONSTRUCTION TO REMAIN, USING POWER-DRIVEN SAW, AND THEN REMOVE

MASONRY BETWEEN SAW CUTS.

3.6 DISPOSAL OF DEMOLISHED MATERIALS

GENERAL: EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE RECYCLED, REUSED,

SALVAGED, REINSTALLED, OR OTHERWISE INDICATED TO REMAIN OWNER'S

PROPERTY, REMOVE DEMOLISHED MATERIALS FROM PROJECT SITE AND LEGALLY

DISPOSE OF THEM IN AN EPA-APPROVED LANDFILL.

DO NOT ALLOW DEMOLISHED MATERIALS TO ACCUMULATE ON-SITE.

REMOVE AND TRANSPORT DEBRIS IN A MANNER THAT WILL PREVENT

SPILLAGE ON ADJACENT SURFACES AND AREAS.

REMOVE DEBRIS FROM ELEVATED PORTIONS OF BUILDING BY CHUTE, HOIST,

OR OTHER DEVICE THAT WILL CONVEY DEBRIS TO GRADE LEVEL IN A

CONTROLLED DESCENT.

BURNING: DO NOT BURN DEMOLISHED MATERIALS.

DISPOSAL: TRANSPORT DEMOLISHED MATERIALS OFF OWNER'S PROPERTY AND

LEGALLY DISPOSE OF THEM.

A.

A.

B.

1.

2.

3.

4.

C.

D.

A.

B.

1.

C.

D.

1.

E.

A.

A.

B.

A.

B.

C.

D.

E.

1.

F.

1.

A.

1.

B.

1.

2.

3.

4.

a.

b.

c.

d.

e.

f.

g.

A.

1.

B.

1.

2.

3.

4.

024119 SELECTIVE DEMOLITION

1.1 MATERIALS OWNERSHIP

UNLESS OTHERWISE INDICATED, DEMOLITION WASTE BECOMES PROPERTY OF

CONTRACTOR.

1.2 INFORMATIONAL SUBMITTALS

PROPOSED PROTECTION MEASURES: SUBMIT REPORT, INCLUDING DRAWINGS, THAT

INDICATES THE MEASURES PROPOSED FOR PROTECTING INDIVIDUALS AND

PROPERTY, FOR ENVIRONMENTAL PROTECTION, FOR DUST CONTROL AND, FOR

NOISE CONTROL. INDICATE PROPOSED LOCATIONS AND CONSTRUCTION OF

BARRIERS.

SCHEDULE OF SELECTIVE DEMOLITION ACTIVITIES: INDICATE THE FOLLOWING:

DETAILED SEQUENCE OF SELECTIVE DEMOLITION AND REMOVAL WORK, WITH

STARTING AND ENDING DATES FOR EACH ACTIVITY. ENSURE OWNER'S ON-

SITE OPERATIONS ARE UNINTERRUPTED.

INTERRUPTION OF UTILITY SERVICES. INDICATE HOW LONG UTILITY SERVICES

WILL BE INTERRUPTED.

COORDINATION FOR SHUTOFF, CAPPING, AND CONTINUATION OF UTILITY

SERVICES.

COORDINATION OF OWNER'S CONTINUING OCCUPANCY OF PORTIONS OF

EXISTING SITE AND OF OWNER'S PARTIAL OCCUPANCY OF COMPLETED WORK.

SEE SECTION 010100, SUMMARY OF WORK.

INVENTORY: SUBMIT A LIST OF ITEMS TO BE REMOVED AND SALVAGED AND DELIVER

TO OWNER PRIOR TO START OF DEMOLITION.

PRE-DEMOLITION PHOTOGRAPHS OR VIDEO: SUBMIT BEFORE WORK BEGINS.

1.3 FIELD CONDITIONS

NOTIFY ARCHITECT OF DISCREPANCIES BETWEEN EXISTING CONDITIONS AND

DRAWINGS BEFORE PROCEEDING WITH SELECTIVE DEMOLITION.

HAZARDOUS MATERIALS: IT IS NOT EXPECTED THAT HAZARDOUS MATERIALS WILL BE

ENCOUNTERED IN THE WORK.

IF SUSPECTED HAZARDOUS MATERIALS ARE ENCOUNTERED, DO NOT

DISTURB; IMMEDIATELY NOTIFY ARCHITECT AND OWNER. HAZARDOUS

MATERIALS WILL BE REMOVED BY OWNER UNDER A SEPARATE CONTRACT.

STORAGE OR SALE OF REMOVED ITEMS OR MATERIALS ON-SITE IS NOT PERMITTED.

UTILITY SERVICE: MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN IN SERVICE

AND PROTECT THEM AGAINST DAMAGE DURING SELECTIVE DEMOLITION

OPERATIONS.

MAINTAIN FIRE-PROTECTION FACILITIES IN SERVICE DURING SELECTIVE

DEMOLITION OPERATIONS.

ARRANGE SELECTIVE DEMOLITION SCHEDULE SO AS NOT TO INTERFERE WITH

OWNER'S OPERATIONS.

1.4 WARRANTY

EXISTING WARRANTIES: REMOVE, REPLACE, PATCH, AND REPAIR MATERIALS AND

SURFACES CUT OR DAMAGED DURING SELECTIVE DEMOLITION, BY METHODS AND

WITH MATERIALS AND USING APPROVED CONTRACTORS SO AS NOT TO VOID

EXISTING WARRANTIES.

2.1 PERFORMANCE CRITERIA

REGULATORY REQUIREMENTS: COMPLY WITH GOVERNING EPA NOTIFICATION

REGULATIONS BEFORE BEGINNING SELECTIVE DEMOLITION. COMPLY WITH HAULING

AND DISPOSAL REGULATIONS OF AUTHORITIES HAVING JURISDICTION.

STANDARDS: COMPLY WITH ASSE A10.6 AND NFPA 241.

3.1 EXAMINATION

VERIFY THAT UTILITIES HAVE BEEN DISCONNECTED AND CAPPED BEFORE STARTING

SELECTIVE DEMOLITION OPERATIONS.

REVIEW RECORD DOCUMENTS OF EXISTING CONSTRUCTION PROVIDED BY OWNER.

OWNER DOES NOT GUARANTEE THAT EXISTING CONDITIONS ARE SAME AS THOSE

INDICATED IN RECORD DOCUMENTS.

SURVEY EXISTING CONDITIONS AND CORRELATE WITH REQUIREMENTS INDICATED

TO DETERMINE EXTENT OF SELECTIVE DEMOLITION REQUIRED.

WHEN UNANTICIPATED MECHANICAL, ELECTRICAL, OR STRUCTURAL ELEMENTS THAT

CONFLICT WITH INTENDED FUNCTION OR DESIGN ARE ENCOUNTERED, INVESTIGATE

AND MEASURE THE NATURE AND EXTENT OF CONFLICT. PROMPTLY SUBMIT A

WRITTEN REPORT TO ARCHITECT.

ENGAGE A PROFESSIONAL ENGINEER TO PERFORM AN ENGINEERING SURVEY OF

CONDITION OF SITE TO DETERMINE WHETHER REMOVING ANY ELEMENT MIGHT

RESULT IN STRUCTURAL DEFICIENCY OR UNPLANNED COLLAPSE OF ANY PORTION

OF STRUCTURE OR ADJACENT STRUCTURES DURING SELECTIVE BUILDING

DEMOLITION OPERATIONS.

PERFORM SURVEYS AS THE WORK PROGRESSES TO DETECT HAZARDS

RESULTING FROM SELECTIVE DEMOLITION ACTIVITIES.

SURVEY OF EXISTING CONDITIONS: RECORD EXISTING CONDITIONS BY USE OF

MEASURED DRAWINGS, PRECONSTRUCTION PHOTOGRAPHS, PRECONSTRUCTION

VIDEOTAPES, AND TEMPLATES.

INVENTORY AND RECORD THE CONDITION OF ITEMS TO BE REMOVED AND

SALVAGED. PROVIDE PHOTOGRAPHS OR VIDEO OF CONDITIONS THAT MIGHT

BE MISCONSTRUED AS DAMAGE CAUSED BY SALVAGE OPERATIONS.

3.2 UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEMS

EXISTING SERVICES/SYSTEMS TO REMAIN: MAINTAIN SERVICES/SYSTEMS INDICATED

TO REMAIN AND PROTECT THEM AGAINST DAMAGE.

COMPLY WITH REQUIREMENTS FOR EXISTING SERVICES/SYSTEMS

INTERRUPTIONS SPECIFIED IN DIVISION 01 SECTION "SUMMARY."

EXISTING SERVICES/SYSTEMS TO BE REMOVED, RELOCATED, OR ABANDONED:

LOCATE, IDENTIFY, DISCONNECT, AND SEAL OR CAP OFF UTILITY SERVICES AND

MECHANICAL/ELECTRICAL SYSTEMS SERVING AREAS TO BE SELECTIVELY

DEMOLISHED.

OWNER WILL ARRANGE TO SHUT OFF INDICATED SERVICES/SYSTEMS WHEN

REQUESTED BY CONTRACTOR.

ARRANGE TO SHUT OFF UTILITIES WITH UTILITY COMPANIES.

IF SERVICES/SYSTEMS ARE REQUIRED TO BE REMOVED, RELOCATED, OR

ABANDONED, PROVIDE TEMPORARY SERVICES/SYSTEMS THAT BYPASS AREA

OF SELECTIVE DEMOLITION AND THAT MAINTAIN CONTINUITY OF

SERVICES/SYSTEMS.

DISCONNECT, DEMOLISH, AND REMOVE FIRE-SUPPRESSION SYSTEMS,

PLUMBING, AND HVAC SYSTEMS, EQUIPMENT, AND COMPONENTS INDICATED

ON DRAWINGS TO BE REMOVED.

PIPING TO BE REMOVED: REMOVE PORTION OF PIPING INDICATED TO

BE REMOVED AND CAP OR PLUG REMAINING PIPING WITH SAME OR

COMPATIBLE PIPING MATERIAL.

PIPING TO BE ABANDONED IN PLACE: DRAIN PIPING AND CAP OR PLUG

PIPING WITH SAME OR COMPATIBLE PIPING MATERIAL.

EQUIPMENT TO BE REMOVED: DISCONNECT AND CAP SERVICES AND

REMOVE EQUIPMENT.

EQUIPMENT TO BE REMOVED AND REINSTALLED: DISCONNECT AND

CAP SERVICES AND REMOVE, CLEAN, AND STORE EQUIPMENT; WHEN

APPROPRIATE, REINSTALL, RECONNECT, AND MAKE EQUIPMENT

OPERATIONAL.

EQUIPMENT TO BE REMOVED AND SALVAGED: DISCONNECT AND CAP

SERVICES AND REMOVE EQUIPMENT AND DELIVER TO OWNER.

DUCTS TO BE REMOVED: REMOVE PORTION OF DUCTS INDICATED TO

BE REMOVED AND PLUG REMAINING DUCTS WITH SAME OR

COMPATIBLE DUCTWORK MATERIAL.

DUCTS TO BE ABANDONED IN PLACE: CAP OR PLUG DUCTS WITH SAME

OR COMPATIBLE DUCTWORK MATERIAL AND LEAVE IN PLACE.

3.3 PREPARATION

SITE ACCESS AND TEMPORARY CONTROLS: CONDUCT SELECTIVE DEMOLITION AND

DEBRIS-REMOVAL OPERATIONS TO ENSURE MINIMUM INTERFERENCE WITH ROADS,

STREETS, WALKS, WALKWAYS, AND OTHER ADJACENT OCCUPIED AND USED

FACILITIES.

COMPLY WITH REQUIREMENTS FOR ACCESS AND PROTECTION SPECIFIED IN

DIVISION 01 SECTION "TEMPORARY FACILITIES AND CONTROLS."

TEMPORARY FACILITIES: PROVIDE TEMPORARY BARRICADES AND OTHER

PROTECTION REQUIRED TO PREVENT INJURY TO PEOPLE AND DAMAGE TO

ADJACENT BUILDINGS AND FACILITIES TO REMAIN.

PROVIDE PROTECTION TO ENSURE SAFE PASSAGE OF PEOPLE AROUND

SELECTIVE DEMOLITION AREA AND TO AND FROM OCCUPIED PORTIONS OF

BUILDING.

PROVIDE TEMPORARY WEATHER PROTECTION, DURING INTERVAL BETWEEN

SELECTIVE DEMOLITION OF EXISTING CONSTRUCTION ON EXTERIOR

SURFACES AND NEW CONSTRUCTION, TO PREVENT WATER LEAKAGE AND

DAMAGE TO STRUCTURE AND INTERIOR AREAS.

PROTECT WALLS, CEILINGS, FLOORS, AND OTHER EXISTING FINISH WORK

THAT ARE TO REMAIN OR THAT ARE EXPOSED DURING SELECTIVE

DEMOLITION OPERATIONS.

COMPLY WITH REQUIREMENTS FOR TEMPORARY ENCLOSURES, DUST

CONTROL, HEATING, AND COOLING SPECIFIED IN DIVISION 01 SECTION

"TEMPORARY FACILITIES AND CONTROLS."

OS

OS OS

OS

OS

OS

OS OS

OS

OS

MATCH LINE

THIS SHEET

MATCH LINE

THIS SHEET

MATCH LINE

THIS SHEET

MATCH LINE

THIS SHEET

W

IL

LI

AM

A . K

IB

BE

A

SS

O

C

IA

TE

S, IN

C

E

N G

IN

E

E R

S

A R

C H

IT

E

C

TS

S

U R

V E

Y O

R S

PR

IN

TE

D:

SHEET

PROJ #:

DRAWN BY:

DES'D BY:

CHCK'D BY:

/8/

2:

:33 P

M

25-0543-0153

B. KUSHION

B. KUSHION

E. MARTER

S- W

IN

G

LO

W

ER

LE

VE

L L

IG

HT

IN

G

DE

MO

LIT

IO

N

PL

AN

DE

LT

A

CO

LL

EG

E S-

W

IN

G

CO

RR

ID

OR

LI

GH

TI

NG

E1.0

©2

7 - A

LL

R

IG

HT

S

RE

SE

RV

ED

. T

HI

S

DO

CU

ME

NT

A

ND

D

ES

IG

NS

P

OR

TR

AY

ED

W

IT

HI

N

AR

E

TH

E

PR

OP

ER

TY

O

F W

AK

, N

O

MO

DI

FI

CA

TI

ON

S

AN

D/

OR

T

RA

NS

FE

RS

O F

W

OR

K

AR

E

PE

RM

IT

TE

D

UN

LE

SS

G

RA

NT

ED

B

Y W

AK

UN

IV

ER

SI

TY

C

EN

TE

R

MI

N E1.0 SCALE: 1/8" = 1'-0"

S-WING LOWER LEVEL LIGHTING DEMOLITION PLAN1

SYMBOL DESCRIPTION

KEYED DEMOLITION NOTES

1 DISCONNECT AND REMOVE ALL

SURFACE MOUNTED STRIP LIGHTS IN

RECESSED SOFFIT & EGG CRATE

DIFFUSERS. SALVAGE CIRCUITS AND

CONTROLS TO BE USED WITH NEW

LIGHTS.

2 VERIFY EMERGENCY LIGHTING CIRCUIT,

DISCONNECT AND REMOVE SURFACE

MOUNTED STRIP LIGHTS IN RECESSED

SOFFIT. SALVAGE EMERGENCY LIGHTING

CIRCUITS TO BE USED WITH NEW

LIGHTS.

3 DISCONNECT AND REMOVE LIGHTING.

SALVAGE CIRCUITS AND CONTROLS TO

BE USED WITH NEW LIGHTS.

4 DISCONNECT AND REMOVE LINEAR

PENDANT MOUNT LIGHTING. SALVAGE

CIRCUIT TO BE USED WITH NEW LIGHTS.

5 DISCONNECT AND REMOVE EXISTING

LIGHTING CONTROLS. SALVAGE

LOCATIONS FOR NEW CONTROLS.

NO

ST

AT

US

/ R

EV

IS

IO

NS

DA

TE

O W

NE

R

RE

VI

EW

-2 8-

O

W

NE

R

RE

VI

EW

-0

3-

IS

SU

ED

F

OR

B

ID

S

-0

First Floor - Ceiling Grid

110°

FE FEC

FE

OS

OS

OS

First Floor - Ceiling Grid

110°

FE FEC

FE

OS

OS

OS

OS

MATCH LINE

THIS SHEET

MATCH LINE

THIS SHEET

MATCH LINE

THIS SHEET

MATCH LINE

THIS SHEET

W

IL

LI

AM

A . K

IB

BE

A

SS

O

C

IA

TE

S, IN

C

E

N G

IN

E

E R

S

A R

C H

IT

E

C

TS

S

U R

V E

Y O

R S

PR

IN

TE

D:

SHEET

PROJ #:

DRAWN BY:

DES'D BY:

CHCK'D BY:

/8/

2:

:34 P

M

25-0543-0153

B. KUSHION

B. KUSHION

E. MARTER

S- W

IN

G

FI

RS

T

FL

OO

R

LIG

HT

IN

G

DE

MO

LIT

IO

N

PL

AN

DE

LT

A

CO

LL

EG

E S-

W

IN

G

CO

RR

ID

OR

LI

GH

TI

NG

E1.1

©2

7 - A

LL

R

IG

HT

S

RE

SE

RV

ED

. T

HI

S

DO

CU

ME

NT

A

ND

D

ES

IG

NS

P

OR

TR

AY

ED

W

IT

HI

N

AR

E

TH

E

PR

OP

ER

TY

O

F W

AK

, N

O

MO

DI

FI

CA

TI

ON

S

AN

D/

OR

T

RA

NS

FE

RS

O F

W

OR

K

AR

E

PE

RM

IT

TE

D

UN

LE

SS

G

RA

NT

ED

B

Y W

AK

UN

IV

ER

SI

TY

C

EN

TE

R

MI

N E1.1 SCALE: 1/8" = 1'-0"

S-WING FIRST FLOOR LIGHTING DEMOLITION1

SYMBOL DESCRIPTION

KEYED DEMOLITION NOTES

1 DISCONNECT AND REMOVE ALL

SURFACE MOUNTED STRIP LIGHTS IN

RECESSED SOFFIT & EGG CRATE

DIFFUSERS. SALVAGE CIRCUITS AND

CONTROLS TO BE USED WITH NEW

LIGHTS.

2 VERIFY EMERGENCY LIGHTING CIRCUIT,

DISCONNECT AND REMOVE SURFACE

MOUNTED STRIP LIGHTS IN RECESSED

SOFFIT. SALVAGE EMERGENCY LIGHTING

CIRCUITS TO BE USED WITH NEW

LIGHTS.

3 DISCONNECT AND REMOVE LIGHTING.

SALVAGE CIRCUITS AND CONTROLS TO

BE USED WITH NEW LIGHTS.

4 DISCONNECT AND REMOVE LINEAR

PENDANT MOUNT LIGHTING. SALVAGE

CIRCUIT TO BE USED WITH NEW LIGHTS.

5 DISCONNECT AND REMOVE EXISTING

LIGHTING CONTROLS. SALVAGE

LOCATIONS FOR NEW CONTROLS.

NO

ST

AT

US

/ R

EV

IS

IO

NS

DA

TE

O W

NE

R

RE

VI

EW

-2 8-

O

W

NE

R

RE

VI

EW

-0

3-

IS

SU

ED

F

OR

B

ID

S

-0

Second Floor - Master Plan

OS

OS

OS

OS

OS

OS

OS

Second Floor - Master Plan

MATCH LINE

THIS SHEET

MATCH LINE

THIS SHEET

MATCH LINE

THIS SHEET

MATCH LINE

THIS SHEET

2 2

W

IL

LI

AM

A . K

IB

BE

A

SS

O

C

IA

TE

S, IN

C

E

N G

IN

E

E R

S

A R

C H

IT

E

C

TS

S

U R

V E

Y O

R S

PR

IN

TE

D:

SHEET

PROJ #:

DRAWN BY:

DES'D BY:

CHCK'D BY:

/8/

2:

:35 P

M

25-0543-0153

B. KUSHION

B. KUSHION

E. MARTER

S- W

IN

G

SE

CO

ND

F

LO

OR

LI

GH

TI

NG

DE

MO

LIT

IO

N

PL

AN

DE

LT

A

CO

LL

EG

E S-

W

IN

G

CO

RR

ID

OR

LI

GH

TI

NG

E1.2

©2

7 - A

LL

R

IG

HT

S

RE

SE

RV

ED

. T

HI

S

DO

CU

ME

NT

A

ND

D

ES

IG

NS

P

OR

TR

AY

ED

W

IT

HI

N

AR

E

TH

E

PR

OP

ER

TY

O

F W

AK

, N

O

MO

DI

FI

CA

TI

ON

S

AN

D/

OR

T

RA

NS

FE

RS

O F

W

OR

K

AR

E

PE

RM

IT

TE

D

UN

LE

SS

G

RA

NT

ED

B

Y W

AK

UN

IV

ER

SI

TY

C

EN

TE

R

MI

N E1.2 SCALE: 1/8" = 1'-0"

S-WING SECOND FLOOR LIGHTING DEMOLITION1

SYMBOL DESCRIPTION

KEYED DEMOLITION NOTES

1 DISCONNECT AND REMOVE ALL

SURFACE MOUNTED STRIP LIGHTS IN

RECESSED SOFFIT & EGG CRATE

DIFFUSERS. SALVAGE CIRCUITS AND

CONTROLS TO BE USED WITH NEW

LIGHTS.

2 VERIFY EMERGENCY LIGHTING CIRCUIT,

DISCONNECT AND REMOVE SURFACE

MOUNTED STRIP LIGHTS IN RECESSED

SOFFIT. SALVAGE EMERGENCY LIGHTING

CIRCUITS TO BE USED WITH NEW

LIGHTS.

3 DISCONNECT AND REMOVE LIGHTING.

SALVAGE CIRCUITS AND CONTROLS TO

BE USED WITH NEW LIGHTS.

4 DISCONNECT AND REMOVE LINEAR

PENDANT MOUNT LIGHTING. SALVAGE

CIRCUIT TO BE USED WITH NEW LIGHTS.

5 DISCONNECT AND REMOVE EXISTING

LIGHTING CONTROLS. SALVAGE

LOCATIONS FOR NEW CONTROLS.

NO

ST

AT

US

/ R

EV

IS

IO

NS

DA

TE

O W

NE

R

RE

VI

EW

-2 8-

O

W

NE

R

RE

VI

EW

-0

3-

IS

SU

ED

F

OR

B

ID

S

-0

OS OS

OS

OS

OS

OS OS

OS

OS

MATCH LINE

THIS SHEET

MATCH LINE

THIS SHEET

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

B B

BB B B

BB

BB

B B

B B

B B

2 2

2 2

E8.0

MATCH LINE

THIS SHEET

MATCH LINE

THIS SHEET

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

B

BB

B

W

IL

LI

AM

A . K

IB

BE

A

SS

O

C

IA

TE

S, IN

C

E

N G

IN

E

E R

S

A R

C H

IT

E

C

TS

S

U R

V E

Y O

R S

PR

IN

TE

D:

SHEET

PROJ #:

DRAWN BY:

DES'D BY:

CHCK'D BY:

/8/

2:

:35 P

M

25-0543-0153

B. KUSHION

B. KUSHION

E. MARTER

S- W

IN

G

LO

W

ER

LE

VE

L L

IG

HT

IN

G

PL

AN

DE

LT

A

CO

LL

EG

E S-

W

IN

G

CO

RR

ID

OR

LI

GH

TI

NG

E3.0

©2

7 - A

LL

R

IG

HT

S

RE

SE

RV

ED

. T

HI

S

DO

CU

ME

NT

A

ND

D

ES

IG

NS

P

OR

TR

AY

ED

W

IT

HI

N

AR

E

TH

E

PR

OP

ER

TY

O

F W

AK

, N

O

MO

DI

FI

CA

TI

ON

S

AN

D/

OR

T

RA

NS

FE

RS

O F

W

OR

K

AR

E

PE

RM

IT

TE

D

UN

LE

SS

G

RA

NT

ED

B

Y W

AK

UN

IV

ER

SI

TY

C

EN

TE

R

MI

N E3.0 SCALE: 1/8" = 1'-0"

S-WING LOWER LEVEL LIGHTING PLAN1

SYMBOL DESCRIPTION

KEYED CONSTRUCTION NOTES

1 CONNECT NEW LIGHT FIXTURE TO

EMERGENCY LIGHTING CIRCUIT.

2 INSTALL NEW LIGHT FIXTURES IN

EXISTING CEILING & CONNECT TO

SALVAGED CIRCUIT. PROVIDE CEILING

TILES & GRID AS NECESSARY TO

COMPLETE THE CEILING INSTALLATION.

3 PROVIDE RCMS PDT 9 AR G2

OCCUPANCY SENSOR WITH RPP20 D 24V

EFP G2 POWER PACK.

4 PROVIDE RPODLA DX MVOLT WH G2 LINE

POWERED WALL SWITCH.

NO

ST

AT

US

/ R

EV

IS

IO

NS

DA

TE

O W

NE

R

RE

VI

EW

-2 8-

O

W

NE

R

RE

VI

EW

-0

3-

IS

SU

ED

F

OR

B

ID

S

-0

8-

GENERAL NOTE:

REFER TO DETAIL ONE ON SHEET

E8.0 FOR TYPICAL CEILING & LIGHT

FIXTURE MODIFICATION DETAIL

NEW CEILING TILES & GRID TO

MATCH EXISTING

First Floor - Ceiling Grid

110°

FE FEC

FE

OS

OS

OS

OS

First Floor - Ceiling Grid

110°

FE FEC

FE

OS

OS

OS

MATCH LINE

THIS SHEET

MATCH LINE

THIS SHEET

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

1 1

MATCH LINE

THIS SHEET

MATCH LINE

THIS SHEET

C

C

C

C

C

C

C

C

C

C

C

C

W

IL

LI

AM

A . K

IB

BE

A

SS

O

C

IA

TE

S, IN

C

E

N G

IN

E

E R

S

A R

C H

IT

E

C

TS

S

U R

V E

Y O

R S

PR

IN

TE

D:

SHEET

PROJ #:

DRAWN BY:

DES'D BY:

CHCK'D BY:

/8/

2:

:36 P

M

25-0543-0153

B. KUSHION

B. KUSHION

E. MARTER

S- W

IN

G

FI

RS

T

FL

OO

R

LIG

HT

IN

G

PL

AN

DE

LT

A

CO

LL

EG

E S-

W

IN

G

CO

RR

ID

OR

LI

GH

TI

NG

E3.1

©2

7 - A

LL

R

IG

HT

S

RE

SE

RV

ED

. T

HI

S

DO

CU

ME

NT

A

ND

D

ES

IG

NS

P

OR

TR

AY

ED

W

IT

HI

N

AR

E

TH

E

PR

OP

ER

TY

O

F W

AK

, N

O

MO

DI

FI

CA

TI

ON

S

AN

D/

OR

T

RA

NS

FE

RS

O F

W

OR

K

AR

E

PE

RM

IT

TE

D

UN

LE

SS

G

RA

NT

ED

B

Y W

AK

UN

IV

ER

SI

TY

C

EN

TE

R

MI

N E3.1 SCALE: 1/8" = 1'-0"

S-WING FIRST FLOOR LIGHTING PLAN1

SYMBOL DESCRIPTION

KEYED CONSTRUCTION NOTES

1 CONNECT NEW LIGHT FIXTURE TO

EMERGENCY LIGHTING CIRCUIT.

2 INSTALL NEW LIGHT FIXTURES IN

EXISTING CEILING & CONNECT TO

SALVAGED CIRCUIT. PROVIDE CEILING

TILES & GRID AS NECESSARY TO

COMPLETE THE CEILING INSTALLATION.

3 PROVIDE RCMS PDT 9 AR G2

OCCUPANCY SENSOR WITH RPP20 D 24V

EFP G2 POWER PACK.

4 PROVIDE RPODLA DX MVOLT WH G2 LINE

POWERED WALL SWITCH.

NO

ST

AT

US

/ R

EV

IS

IO

NS

DA

TE

O W

NE

R

RE

VI

EW

-2 8-

O

W

NE

R

RE

VI

EW

-0

3-

IS

SU

ED

F

OR

B

ID

S

-0

8-

GENERAL NOTE:

REFER TO DETAIL ONE ON SHEET

E8.0 FOR TYPICAL CEILING & LIGHT

FIXTURE MODIFICATION DETAIL

Second Floor - Master Plan

OS

OS

OS

LV

D

LV

D

PP

PP

PP

PP

OS

OS

OS

OS

PP

LVD

Second Floor - Master Plan

MATCH LINE

THIS SHEET

MATCH LINE

THIS SHEET

F F F F

FFFF

F F F F

F

FF

FF

FF

F

F

F

F F F F

FF

FF

F F

FFFF

F F

FF

F F

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A A

A

A

A

A

A

A

A

A

B

B

B

B

BB

B B

B

B

B

B

B

B

ART ROOM LIGHTING NOTES:

PENDANT MOUNT FIXTURES OF TYPE F 9'-9" A.F.F.

SET FIXTURES TO MANUAL ON TO 100% LIGHT

OUTPUT. ON/OFF & DIMMING PROVIDED VIA LOCAL

SWITCHING. AUTO OFF AFTER 20 MINUTE VACANCY.

MATCH LINE

THIS SHEET

MATCH LINE

THIS SHEET

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

AA

A

A

A

A

A

A

A

A

A

A

A

A

A

B

B

B

B

B

B B

B

D

D

D

B

B B

B

B

B

W

IL

LI

AM

A . K

IB

BE

A

SS

O

C

IA

TE

S, IN

C

E

N G

IN

E

E R

S

A R

C H

IT

E

C

TS

S

U R

V E

Y O

R S

PR

IN

TE

D:

SHEET

PROJ #:

DRAWN BY:

DES'D BY:

CHCK'D BY:

/8/

2:

:37 P

M

25-0543-0153

B. KUSHION

B. KUSHION

E. MARTER

S- W

IN

G

SE

CO

ND

F

LO

OR

LI

GH

TI

NG

P

LA

N

DE

LT

A

CO

LL

EG

E

S- W

IN

G

CO

RR

ID

OR

LI

GH

TI

NG

E3.2

©2

7 - A

LL

R

IG

HT

S

RE

SE

RV

ED

. T

HI

S

DO

CU

ME

NT

A

ND

D

ES

IG

NS

P

OR

TR

AY

ED

W

IT

HI

N

AR

E

TH

E

PR

OP

ER

TY

O

F W

AK

, N

O

MO

DI

FI

CA

TI

ON

S

AN

D/

OR

T

RA

NS

FE

RS

O F

W

OR

K

AR

E

PE

RM

IT

TE

D

UN

LE

SS

G

RA

NT

ED

B

Y W

AK

UN

IV

ER

SI

TY

C

EN

TE

R

MI

N E3.2 SCALE: 1/8" = 1'-0"

S-WING SECOND FLOOR LIGHTING PLAN1

SYMBOL DESCRIPTION

KEYED CONSTRUCTION NOTES

1 CONNECT NEW LIGHT FIXTURE TO

EMERGENCY LIGHTING CIRCUIT.

2 INSTALL NEW LIGHT FIXTURES IN

EXISTING CEILING & CONNECT TO

SALVAGED CIRCUIT. PROVIDE CEILING

TILES & GRID AS NECESSARY TO

COMPLETE THE CEILING INSTALLATION.

3 PROVIDE RCMS PDT 9 AR G2

OCCUPANCY SENSOR WITH RPP20 D 24V

EFP G2 POWER PACK.

4 PROVIDE RPODLA DX MVOLT WH G2 LINE

POWERED WALL SWITCH.

NO

ST

AT

US

/ R

EV

IS

IO

NS

DA

TE

O W

NE

R

RE

VI

EW

-2 8-

O

W

NE

R

RE

VI

EW

-0

3-

IS

SU

ED

F

OR

B

ID

S

-0

8-

GENERAL NOTE:

REFER TO DETAIL ONE ON SHEET

E8.0 FOR TYPICAL CEILING & LIGHT

FIXTURE MODIFICATION DETAIL

EXISTING CEILING GRID TO REMAIN

REMOVE OR MODIFY EXISTING

CEILING GRID

NEW CEILING GRID AS REQUIRED

TO ACCOMMODATE NEW CEILING

TILES AND LIGHT FIXTURES

LEGEND:

W

IL

LI

AM

A . K

IB

BE

A

SS

O

C

IA

TE

S, IN

C

E

N G

IN

E

E R

S

A R

C H

IT

E

C

TS

S

U R

V E

Y O

R S

PR

IN

TE

D:

SHEET

PROJ #:

DRAWN BY:

DES'D BY:

CHCK'D BY:

/8/

2:

:37 P

M

25-0543-0153

B. KUSHION

B. KUSHION

E. MARTER

DE

TA

ILS

DE

LT

A

CO

LL

EG

E

S- W

IN

G

CO

RR

ID

OR

LI

GH

TI

NG

E8.0

©2

7 - A

LL

R

IG

HT

S

RE

SE

RV

ED

. T

HI

S

DO

CU

ME

NT

A

ND

D

ES

IG

NS

P

OR

TR

AY

ED

W

IT

HI

N

AR

E

TH

E

PR

OP

ER

TY

O

F W

AK

, N

O

MO

DI

FI

CA

TI

ON

S

AN

D/

OR

T

RA

NS

FE

RS

O F

W

OR

K

AR

E

PE

RM

IT

TE

D

UN

LE

SS

G

RA

NT

ED

B

Y W

AK

UN

IV

ER

SI

TY

C

EN

TE

R

MI

SCALE: 1/4" = 1'-0"E8.0

TYPICAL CEILING & LIGHT FIXTURE MODIFICATION DETAIL1

1 REMOVE EXISTING EGG CRATE GRILLS.

2 REMOVE EXISTING 2' CROSS TEE AS

REQUIRED TO ACCOMADATE NEW 1'x4'

LIGHT.

1 INSTALL NEW 2'x2" CEILING TILES. CUT

TO FIT IN EXISTING GRID. MATCH

EXISTING.

2 INSTALL NEW 2'x2" CEILING TILES. CUT

TO FIT IN EXISTING GRID. MATCH

EXISTING.

3 PROPOSED 1'x4' LED LIGHT FIXTURE. SEE

LIGHTING FIXTURE SCHEDULE.

SYMBOL DESCRIPTION

KEYED DEMOLITION NOTES

SYMBOL DESCRIPTION

KEYED CONSTRUCTION NOTES

NO

ST

AT

US

/ R

EV

IS

IO

NS

DA

TE

IS

SU

ED

F

OR

B

ID

S

-0

CS - COVER SHEET
E0.0 - GENERAL NOTES
E0.1 - SPECIFICATIONS
E1.0 - S-WING LOWER LEVEL LIGHTING DEMOLITION PLAN
E1.1 - S-WING FIRST FLOOR LIGHTING DEMOLITION PLAN
E1.2 - S-WING SECOND FLOOR LIGHTING DEMOLITION PLAN
E3.0 - S-WING LOWER LEVEL LIGHTING PLAN
E3.1 - S-WING FIRST FLOOR LIGHTING PLAN
E3.2 - S-WING SECOND FLOOR LIGHTING PLAN
E8.0 - DETAILS

File details come from the government source that posted it. Updated .