25.10.08 S Wing Corridor Lighting - Drawings IFB.pdf
PDF 957 KB Posted
- Attached to
- Delta College S Wing Corridor Lighting
- Solicitation number
- 2025010
- Issued by
- Bay County, Warren City, Michigan
About this file
This document is a set of architectural and electrical engineering drawings for the Delta College S-Wing Corridor Lighting project located at 1961 Delta Road in University Center, Michigan 48710. The project involves comprehensive lighting renovations across the lower, first, and second floors of the S-Wing, including detailed demolition and new construction lighting plans. The drawings are prepared by William A. Kibbe & Associates, Inc. and include multiple technical specifications, including building code compliance with 2021 Michigan Rehabilitation, Building, Plumbing, and Mechanical Codes, as well as the 2023 National Electric Code and 2015 International Fire Code.
The technical drawings provide extensive details about electrical work, including general notes on electrical installations, grounding applications, identification systems, and power conductor specifications. The project involves systematic replacement of existing lighting fixtures, with careful attention to code compliance, electrical safety, and proper installation techniques. The drawings include specific symbols, legends, and modification details for ceiling and light fixture changes, covering the entire S-Wing corridor across multiple floors. The documentation demonstrates a comprehensive approach to modernizing the building's lighting infrastructure while maintaining strict adherence to current electrical and safety standards.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Pricing Sheet.docx | DOCX document | |
| 25.10.08 S Wing Corridor Lighting - Specs IFB.pdf | ||
| Introduction Page.docx | DOCX document | |
| Addendum-Q_A (1).docx | DOCX document | |
| Certifications.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
E. SALZBURG RD.
E. HOTCHKISS RD.
DELTA RD.
MIDLAND RD.
US-10
BAY CITY
SAGINAW
TO MIDLAND
S.
M
AC
KI
NA
W
R D.
7 M
ILE
R D.
SA
GI
NA
W
R
IV
ER
W
IL
LI
AM
A . K
IB
BE
A
SS
O
C
IA
TE
S, IN
C
E
N G
IN
E
E R
S
A R
C H
IT
E
C
TS
S
U R
V E
Y O
R S
PR
IN
TE
D:
SHEET
PROJ #:
DRAWN BY:
DES'D BY:
CHCK'D BY:
/8/
2:
:31 P
M
©2
7 - A
LL
R
IG
HT
S
RE
SE
RV
ED
. T
HI
S
DO
CU
ME
NT
A
ND
D
ES
IG
NS
P
OR
TR
AY
ED
W
IT
HI
N
AR
E
TH
E
PR
OP
ER
TY
O
F W
AK
, N
O
MO
DI
FI
CA
TI
ON
S
AN
D/
OR
T
RA
NS
FE
RS
O F
W
OR
K
AR
E
PE
RM
IT
TE
D
UN
LE
SS
G
RA
NT
ED
B
Y W
AK DELTA COLLEGE
UNIVERSITY CENTER MI 48710
1961 DELTA RD
S-WING CORRIDOR LIGHTING
25-0543-0153
B. KUSHION
B. KUSHION
E. MARTER
CO
VE
R
SH
EE
T
DE
LT
A
CO
LL
EG
E S-
W
IN
G
CO
RR
ID
OR
LI
GH
TI
NG
CS
UN
IV
ER
SI
TY
C
EN
TE
R
MI
WILLIAM A. KIBBE & ASSOCIATES, INC.
ENGINEERS | ARCHITECTS | SURVEYORS
PHONE:
EMAIL:
WEB:
PROJECT MANAGER
www.kibbe.com
PHONE:
EMAIL:
PROJECT DESIGNER
CODE AUTHORITY:
OWNER / CLIENT:
PHONE:
EMAIL:
DELTA COLLEGE
CONTACT INFORMATIONLOCATION MAP PROJECT INFORMATION
1961 DELTA RD
UNIVERSITY CENTER, MICHIGAN 48710
(989) 686-9000
ANTHONY KHALIL
PROJECT MANAGER/STAFF ARCHITECT
(989) 686-9407 anthonykhalil@delta.edu
SHEET INDEX
NU
MB
ER
TITLE 08
-2
8-
O W
NE
R
RE
VI
EW
-0
3-
O W
NE
R
RE
VI
EW
-0 8-
IS
SU
ED
F
OR
B
ID
S
GENERAL
CS COVER SHEET X X X
ELECTRICAL
E0.0 GENERAL NOTES X X X
E0.1 SPECIFICATIONS X
E1.0 S-WING LOWER LEVEL LIGHTING DEMOLITION PLAN X X X
E1.1 S-WING FIRST FLOOR LIGHTING DEMOLITION PLAN X X X
E1.2 S-WING SECOND FLOOR LIGHTING DEMOLITION PLAN X X X
E3.0 S-WING LOWER LEVEL LIGHTING PLAN X X X
E3.1 S-WING FIRST FLOOR LIGHTING PLAN X X X
E3.2 S-WING SECOND FLOOR LIGHTING PLAN X X X
E8.0 DETAILS X
ERIC MARTER
(989) 752-5000 emarter@kibbe.com
BRANDON KUSHION
(989) 752-5000 bkushion@kibbe.com
FRANKENLUST TOWNSHIP
2401 DELTA RD
BAY CITY, MI 48706
(989) 860-2219
LES LUPTOWSKI
BUILDING INSPECTOR
PHONE: (989) 239-0360
STATE OF MICHIGAN
BUREAU OF FIRE SERVICES (BFS)
611 W. OTTAWA ST., 4TH FLR
P.O. BOX 30700
LANSING, MI 48909
WWW.MICHIGAN.GOV/BFS
(517) 241-8847
BUILDING CODE COMPLIANCE
2021 MICHIGAN REHABILITATION CODE (MRC)
2021 MICIGAN BUILDING CODE (MBC)
2021 MICHIGAN PLUMBING CODE (MPC)
2021 MICHIGAN MECHANCIAL CODE (MMC)
2023 NATIONAL ELECTRIC CODE (NEC)
2015 INTERNATIONAL FIRE CODE (IFC)
2012 NFPA 101 LIFE SAFETY CODE (LSC)
NO
ST
AT
US
/ R
EV
IS
IO
NS
DA
TE
O W
NE
R
RE
VI
EW
-2 8-
O
W
NE
R
RE
VI
EW
-0
3-
IS
SU
ED
F
OR
B
ID
S
-0
8-
JB
TV
DO
C
R
GF
I C
C GFI
GF
I
GF
I
C
C GFI
PP
S
AD
A
A
##CD
AV
##CD
V
##CD
GF
I
US
B
C
DC
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE LATEST
ACCEPTED EDITION OF THE NATIONAL ELECTRICAL CODE (NEC) AND ALL
STATE AND LOCAL CODES.
COORDINATE THE INSTALLATION OF ALL EQUIPMENT REQUIRING
ELECTRICAL CONNECTIONS WITH ARCHITECTURAL AND MECHANICAL
PLANS, SPECIFICATIONS AND EQUIPMENT DRAWINGS. PROVIDE ALL
NECESSARY EQUIPMENT POWER AND CONTROL CONNECTIONS NOT
PROVIDED BY OTHERS WHETHER INDICATED ON THE DRAWINGS OR NOT.
UNLESS OTHERWISE NOTED, WHERE ELECTRICAL DEMOLITION WORK IS
SHOWN, REMOVE ALL CONDUCTOR AND EXPOSED CONDUITS FROM
EQUIPMENT OR OUTLET LOCATION BACK TO THE POWER SOURCE(S) FOR
THE CIRCUIT.
SEAL ALL WALL AND FLOOR PENETRATIONS TO MAINTAIN RATING.
BACK-TO-BACK OR THROUGH THE WALL BOXES SHALL NOT BE USED.
ALL LOW VOLTAGE CONDUCTORS SHALL BE STRANDED COPPER.
SPLICE CABLES OR CONDUCTORS IN OUTLET BOXES, DEVICE BOXES,
PULL BOXES, JUNCTION BOXES. DO NOT SPLICE CABLES OR
CONDUCTORS IN CONDUIT BODIES.
RECEPTACLES INDICATED AS GROUND FAULT CIRCUIT INTERRUPTER (GFI)
TYPE MUST BE GFI RECEPTACLE, NO FEED THROUGH.
BRANCH CIRCUITS FROM CIRCUIT BREAKER TYPE DISTRIBUTION
EQUIPMENT WHICH SUPPLY MOTOR LOADS THAT ARE LESS THAN 6.0 AMP
SHALL BE PROTECTED BY A 15 AMP CIRCUIT BREAKER.
FINAL CONNECTIONS TO ITEMS SUBJECT TO VIBRATION SHALL BE MADE
WITH LIQUID TIGHT FLEXIBLE METAL CONDUIT. LIQUID TIGHT FLEXIBLE
METAL CONDUIT SHALL NOT BE USED AS A GROUNDING CONDUCTOR.
PROVIDE A SEPARATE GREEN GROUNDING CONDUCTOR.
IN THE EVENT OF CONFLICTS BETWEEN THE REQUIREMENTS OF THE
DRAWINGS AND SPECIFICATIONS OR WITHIN THE DRAWINGS OR
SPECIFICATIONS, THE MORE STRINGENT REQUIREMENT SHALL BE
ASSUMED TO BE CORRECT. REFER UNCERTAINTIES IN REQUIREMENTS
TO THE ENGINEER FOR CLARIFICATION.
ALL BELOW GRADE LOCATIONS WITHIN BUILDINGS ARE DAMP LOCATIONS
UNLESS OTHERWISE NOTED.
120V AC CONTROL WIRING ASSOCIATED WITH MOTOR CONTROL CIRCUITS
MAY BE RUN IN THE SAME RACEWAY WITH MOTOR POWER WIRING FOR
CONSTANT SPEED MOTORS LESS THAN 30HP. FOR MOTORS 30HP AND
GREATER OR FOR MOTORS POWERED FROM VARIABLE FREQUENCY
CONTROLLERS, SEPARATE RACEWAYS SHALL BE USED FOR POWER AND
CONTROL CONDUCTORS.
120/240V CIRCUIT WIRING FOR ANY ROOM OR AREA MAY BE GROUPED
INTO RACEWAYS AS REQUIRED UNLESS SEPARATE RACEWAYS ARE
REQUIRED BY THE NEC. COMPLY WITH NEC REQUIREMENTS FOR
CONDUCTOR DERATING.
CONDUIT PENETRATIONS OF FLOORS, LOWER LEVEL EXTERIOR WALLS OR
WETWELL WALLS SHALL BE SLEEVED AND SEALED WITH LINKSEAL. SEE
DETAILS ON MECHANICAL DRAWINGS.
IF COMPLIANCE WITH TWO OR MORE DIFFERING STANDARDS,
REQUIREMENTS, DRAWINGS OR SPECIFICATIONS, OR ANY COMBINATION
THEREOF, IS SPECIFIED AND THESE ESTABLISH DIFFERENT OR
CONFLICTING REQUIREMENTS FOR MINIMUM QUANTITIES OR QUALITY
LEVELS, COMPLY WITH THE MOST STRINGENT REQUIREMENT. THE MOST
STRINGENT REQUIREMENT WILL BE THE BETTER QUALITY OR GREATER
QUANTITY OF WORK, AND WILL TYPICALLY BE THE MORE EXPENSIVE
OPTION. REFER UNCERTAINTIES AND REQUIREMENTS THAT ARE
DIFFERENT, BUT APPARENTLY EQUAL, TO ENGINEER FOR A DECISION
BEFORE PROCEEDING.
THE QUANTITY OR QUALITY LEVEL SHOWN OR SPECIFIED SHALL BE THE
MINIMUM PROVIDED OR PERFORMED. THE ACTUAL INSTALLATION MAY
COMPLY EXACTLY WITH THE MINIMUM QUANTITY OR QUALITY SPECIFIED,
OR IT MAY EXCEED THE MINIMUM WITHIN REASONABLE LIMITS. TO
COMPLY WITH THESE REQUIREMENTS, INDICATED NUMERIC VALUES ARE
MINIMUM OR MAXIMUM, AS APPROPRIATE, FOR THE CONTEXT OF
REQUIREMENTS. REFER UNCERTAINTIES TO ENGINEER FOR A DECISION
BEFORE PROCEEDING.
DESIGN DOCUMENTS MUST BE REPRODUCED IN THEIR ENTIRETY,
INCLUDING ALL PLANS, SPECIFICATIONS, AND FRONT END DOCUMENTS.
ONLY COMPLETE DOCUMENT SETS ARE TO BE DISTRIBUTED TO
SUBCONTRACTORS AND SUPPLIERS OF THE CONTRACTOR DURING
BIDDING OR CONSTRUCTION.
FAILURE TO REVIEW AND COMPLY WITH A FULL SET OF CONTRACT
DOCUMENTS WILL NOT BE ACCEPTED AS A VALID REASON FOR FAILURE
TO MEET THE REQUIREMENTS OF THE PLANS AND SPECIFICATIONS.
ALL ABOVE CEILING SYSTEMS AND COMPONENTS (INCLUDING BUT NOT
LIMITED TO MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION,
ETC.) SHALL BE COORDINATED SUCH THAT THE SYSTEMS ARE PROPERLY
INTEGRATED IN THE SPACE PROVIDED ABOVE CEILING AT THE CEILING
HEIGHTS NOTED. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR TO
COORDINATE PATHWAYS WITHIN THE SPACE PROVIDED. CEILING HEIGHTS
WILL NOT BE MODIFIED.
EQUIPMENT SHALL BE MOUNTED 6'-0" AWAY FROM HEAT PRODUCING
EQUIPMENT. U.N.O.
A.F.F. ABOVE FINISHED FLOOR
ALT ALTERNATE
AL ALUMINUM
AWG AMERICAN WIRE GAUGE
AMP OR A AMPERES
ATS AUTOMATIC TRANSFER
BLDG BUILDING
BMS BUILDING MANAGEMENT SYSTEM
CKT CIRCUIT
CB CIRCUIT BREAKER
C CONDUIT
CLG CEILING
CP CONTROL PANEL
CU COPPER
D DATA
DS DISCONNECT SWITCH
DWG DRAWING(S)
EA EACH
EMT ELECTRICAL METALLIC TUBING
EX EXISTING
EXT EXTERNAL
FIN. FLR. FINISH FLOOR
FACP FIRE ALARM CONTROL PANEL
FF FURNITURE FEED
FT FOOT, FEET
GRC GALVANIZED RIGID CONDUIT
GND GROUND
GFCI GROUND FAULT CIRCUIT
INTERUPPTER
GFI GROUND FAULT PROTECTION
HH HAND HOLE
HOA HAND-OFF-AUTO SELECTOR SWITCH
IU INDOOR UNIT
IMC INTERMEDIATE METAL CONDUIT
JB JUNCTION BOX
KVA KILO VOLT-AMPERES
KVAR KILO VOLT-AMPERES REACTIVE
LC LIGHTING CONTRACTOR
MCB MAIN CIRCUIT BREAKER
MDP MAIN DISTRIBUTOR PANEL
MLO MAIN LUGS ONLY
MSB MAIN SWITCH BOARD
MH MAN HOLE
MFR MANUFACTURER'S
MCC MOTOR CONTROL CENTER
MTD MOUNTED
NEC NATIONAL ELECTRIC CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURER'S ASSOCIATION
N.L. NIGHT LIGHT
NC NORMALLY CLOSED CONTACT
NO NORMALLY OPEN CONTACT
N.T.S. NOT TO SCALE
OU OUTDOOR UNIT
O.D. OUTSIDE DIAMETER
OL OVERLOADS-THERMAL
PNL PANEL W/ INDICATION
Ø PHASE
PH PHASE
PC PHOTO-SWITCH
P POLE
PLC PROGRAMMABLE LOGIC CONTROLLER
PB PULL BOX
PTT PUSH-TO-TEST
RMC RIGID METAL COUNT
SPEC SPECIFICATION
SW SWITCH
SWD SWITCHING DUTY
TEL TELEPHONE
TYP TYPICAL
UL UNDERWRITERS LABORATORY
U.N.O. UNLESS NOTED OTHERWISE
VFC VARIABLE FREQUENCY CONTROLLER
VFD VARIABLE FREQUENCY DRIVE
V VOLT
W WATT
WP WEATHER PROOF
W WIRE
W/ WITH
XF/ XFMR TRANSFORMER
XXAF XX AMPERE FUSE
XXAS XX AMPERE SWITCH
XP X POLES
LUMINAIRE: WALL MOUNTED W/ TYPE
LUMINAIRE: RECESSED DOWNLIGHT OR PENDANT W/ TYPE, REFER
TO SCHEDULE
LUMINAIRE: SURFACE OR RECESSED W/ TYPE, REFER TO
SCHEDULE
LUMINAIRE: ON EMERGENCY, LIFE SAFETY, OR LOCAL LIGHTING
CIRCUIT W/ TYPE, REFER TO SCHEDULE
EXIT SIGN: CEILING MOUNTED W/ TYPE, SEE SCHEDULE
EXIT SIGN: WALL MOUNTED W/ TYPE, SEE SCHEDULE
EM LIGHTS: WALL MOUNTED UNO, REFER TO SCHEDULE
REMOTE HEADS: WALL MOUNTED, REFER TO SCHEDULE
TV CONNECTION: 96" TO TOP, COAX CONNECTION, UNO
VOICE/ DATA OUTLET: 18" TO TOP, UNO
VOICE/ DATA OUTLET: CEILING MOUNTED, UNO
VOICE/ DATA/ TV OUTLET: FLOOR MOUNTED, UNO
TELEPHONE: 18" TO TOP, UNO
DATA/ TELEPHONE: 18" TO TOP, UNO
CONTROLS: SPEAKER (SEE SCHEDULE)
CONTROLS: ADA DOOR CONTROL OPENER, COORDINATE
WITH DOOR REQUIREMENTS
CONTROLS: ADA DOOR CONTROL OPENER, COORDINATE
WITH SECURITY, AUTO AND MANUAL CONTROL
SECURITY: PAN - TILT - ZOOM CAMERA
SECURITY: PUSH BUTTON
SECURITY: CARD READER
SECURITY: DOOR CONTACT
FIRE: MANUAL PULL STATION, WALL MOUNTED, 48" AFF TO TOP
UNO
FIRE: AUDIBLE AND VISUAL ANNUNCIATION, WALL MOUNTED, 8'-0"
AFF TO TOP UNO
FIRE: VISUAL ANNUNCIATION, WALL MOUNTED, 8'-0" AFF TO TOP
UNO
FIRE: AUDIBLE ANNUNCIATION, WALL MOUNTED, 8'-0" AFF TO TOP
UNO
FIRE: AUDIBLE AND VISUAL ANNUNCIATION, CEILING MOUNTED
FIRE: VISUAL ANNUNCIATION, CEILING MOUNTED
FIRE: AUDIBLE ANNUNCIATION, CEILING MOUNTED
FIRE: SMOKE DETECTOR, CEILING
FIRE: HEAT DETECTOR, CEILING
FIRE: SMOKE AND HEAT DETECTOR
FIRE: DUCT SMOKE DETECTOR, CEILING, PROVIDED / INSTALLED
BY EC, MOUNTED BY MC, UNO
FIRE ALARM: REMOTE TEST STATION
FIRE: TAMPER SWITCH
FIRE: FLOW SWITCH
FIRE: MAGNETIC DOOR HOLD
FIRE: DOOR LOCK RELEASE
FIRE: PRESSURE SWITCH
DUPLEX RECEPTACLE, 18" A.F.F. TO TOP
DUPLEX RECEPTACLE GFI, 18" A.F.F. TO TOP
DUPLEX RECEPTACLE, CEILING MOUNTED
DUPLEX RECEPTACLE GFI, CEILING MOUNTED
DUPLEX RECEPTACLE USB, 18" A.F.F. TO TOP
DUPLEX RECEPTACLE, 6" ABOVE COUNTER
DUPLEX RECEPTACLE GFI, 6" ABOVE COUNTER
DUPLEX RECEPTACLE SWITCHED, 18" A.F.F. TO TOP
DUPLEX RECEPTACLE, FLOOR MOUNTED
DUPLEX RECEPTACLE GFI , FLOOR MOUNTED
SPECIALTY OUTLET, SEE DRAWINGS W/ MTG HT
QUAD RECEPTACLE, 18" A.F.F. TO TOP
QUAD RECEPTACLE GFI, 18" A.F.F. TO TOP
QUAD RECEPTACLE ONE DUPLEX SWITCHED, 18"
A.F.F. TO TOP
QUAD RECEPTACLE, CEILING MOUNTED
QUAD RECEPTACLE GFI, CEILING MOUNTED
MOTOR SWITCH
OVERHEAD DOOR 3-BUTTON SWITCH, OPEN-
CLOSE-STOP
SWITCH, SINGLE POLE, 48" A.F.F. TO TOP UNO
SWITCH, 3-POLE, 48" A.F.F. TO TOP UNO
SWITCH, 4-POLE, 48" A.F.F. TO TOP UNO
SWITCH, WALL BOX DIMMER, 48" A.F.F. TO TOP UNO
SWITCH, LOW VOLTAGE, 48" A.F.F. TO TOP UNO (VERIFY
W/ FIXTURE)
SWITCH, LOW VOLTAGE DIMMER, 48" A.F.F. TO TOP UNO
(VERIFY W/ FIXTURE)
SWITCH, FUSED: 125V, SINGLE POLE, DUAL ELEMENT
PLUG FUSE
SWITCH, KEYED, 48" A.F.F. TO TOP UNO
SWITCH, PILOT LIGHT, 48" A.F.F. TO TOP UNO
SWITCH, TIMER, 48" A.F.F. TO TOP
SWITCH, MULTI-TECH OCCUPANCY SENSOR, WALL
SWITCH, MULTI-TECH OCCUPANCY SENSOR, CEILING
SWITCH, EXTERIOR PHOTOCELL
POWER PACK FOR OCCUPANCY SENSORS
HOME RUN W/ DIRECTION
ELECTRICAL CIRCUIT
UNDERGROUND ELECTRICAL W/ INCDICATOR
SITE: LIGHT, POLE, AND BASE
TRANSFORMER W/ LABEL
DEVICE OR EQUIPMENT CONNECTION
A
A
POWER POLE
JUNCTION BOX
FURNITURE FEED
MOTOR
NON-FUSED DISCONNECT
COMBINATION MOTOR STARTER/ DISCONNECT
FUSED DISCONNECT
MANUAL MOTOR STARTER
MOTOR STARTER
SURFACE MOUNTED PANEL BOARD
RECESSED PANEL BOARD
OS
PC
PP
AV
V
A
SD
HD
S/H
DSD
TS
FS
DH
FR
#CD
#CD
P
PS
RT
E
UG
XF
D
LV
F
K
P
T
OS
SYMBOL DESCRIPTION
SYMBOL LEGEND
FF
LVD
M
W
IL
LI
AM
A . K
IB
BE
A
SS
O
C
IA
TE
S, IN
C
E
N G
IN
E
E R
S
A R
C H
IT
E
C
TS
S
U R
V E
Y O
R S
PR
IN
TE
D:
SHEET
PROJ #:
DRAWN BY:
DES'D BY:
CHCK'D BY:
/8/
2:
:32 P
M
25-0543-0153
B. KUSHION
B. KUSHION
E. MARTER
GE
NE
RA
L N
OT
ES
DE
LT
A
CO
LL
EG
E S-
W
IN
G
CO
RR
ID
OR
LI
GH
TI
NG
E0.0
©2
7 - A
LL
R
IG
HT
S
RE
SE
RV
ED
. T
HI
S
DO
CU
ME
NT
A
ND
D
ES
IG
NS
P
OR
TR
AY
ED
W
IT
HI
N
AR
E
TH
E
PR
OP
ER
TY
O
F W
AK
, N
O
MO
DI
FI
CA
TI
ON
S
AN
D/
OR
T
RA
NS
FE
RS
O F
W
OR
K
AR
E
PE
RM
IT
TE
D
UN
LE
SS
G
RA
NT
ED
B
Y W
AK
UN
IV
ER
SI
TY
C
EN
TE
R
MI
GENERAL NOTESABBREVIATIONSLIGHTING FIXTURE SCHEDULE
TYPE
NAME
LAMP
DESCRIPTION
BASIS OF DESIGN
COMMENTSTYPE VA VOLT MANUFACTURER CAT. NO.
A LED 42.2 VA 120 V 1X4 LED FLAT PANEL, 3500K, 5000 LUMENS, 80CRI, 0-10V DIMMING LITHONIA LIGHTING CPX 1X4 5000LM 80CRI 35K
SWL MIN1 EZT MVOLT
B LED 17.2 VA 120 V 1X4 LED FLAT PANEL, 3500K, 2000 LUMENS, 80CRI, 0-10V DIMMING LITHONIA LIGHTING CPX 1X4 2000LM 80CRI 35K
SWL MIN1 EZT MVOLT
PROVIDE WITH ACCESSORY DGA14
FOR MOUNTING IN GYP CEILING
C LED 55.4 VA 120 V 1X4 LED FLAT PANEL, 3500K, 6000 LUMENS, 80CRI, 0-10V DIMMING LITHONIA LIGHTING CPX 1X4 6000LM 80CRI 35K
SWL MIN1 EZT MVOLT
D LED 24.6 VA 120 V 2X4 LED FLAT PANEL, 3500K, 3000 LUMENS, 80CRI, 0-10V DIMMING LITHONIA LIGHTING CPX 2X4 3000LM 80CRI 35K
SWL MIN1 EZT MVOLT
PROVIDE WITH ACCESSORY DGA24
FOR MOUNTING IN GYP CEILING
F LED 28.5 VA 120 V 8' LED LINEAR LIGHT, PENDANT MOUNT, 20% UPLIGHT, 80%
DOWNLIGHT, HIGH OUTPUT, SINGLE CIRCUIT, 3500K
FINELITE S12 LED ID - DCO - 8' - 2E - H -
835 - 20U80D - 91 - 120V -
FC-10% - SC - FA - FE - SW - C4
NO
ST
AT
US
/ R
EV
IS
IO
NS
DA
TE
O W
NE
R
RE
VI
EW
-2 8-
O
W
NE
R
RE
VI
EW
-0
3-
IS
SU
ED
F
OR
B
ID
S
-0
A.
A.
1.
2.
3.
A.
B.
C.
D.
E.
F.
A.
1.
2.
3.
4.
B.
C.
A.
B.
C.
A.
1.
2.
3.
4.
5.
6.
7.
8.
9.
A.
B.
C.
A.
B.
C.
D.
E.
F.
G.
A.
B.
C.
A.
1.
2.
3.
4.
B.
C.
D.
1.
2.
3.
A.
A.
DIVISION 26000 - ELECTRICAL SPECIFICATIONS
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 1
SPECIFICATION SECTIONS, APPLY TO THIS SECTION.
1.2 SUBMITTALS
PRODUCT DATA FOR:
WIRING DEVICES
LIGHTING FIXTURES
LIGHTING CONTROLS
1.3 QUALITY ASSURANCE
ELECTRICAL COMPONENTS, DEVICES, AND ACCESSORIES: LISTED AND LABELED AS DEFINED IN NFPA 70, ARTICLE 100, BY A TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, AND MARKED FOR INTENDED USE.
COMPLY WITH UL 467 FOR GROUNDING AND BONDING MATERIALS AND EQUIPMENT.
COMPLY WITH NFPA 70
COMPLY WITH NECA 1, INCLUDING THE MOUNTING HEIGHTS LISTED IN THAT STANDARD, UNLESS OTHERWISE NOTED.
COMPLY WITH APPLICABLE PORTIONS OF NECA1, NEMA PB 1.1, AND NEMA PB 2.1 FOR INSTALLATION OF ENCLOSED SWITCHES AND
CIRCUIT BREAKERS.
SOURCE LIMITATIONS: OBTAIN EACH TYPE OF PRODUCT, EQUIPMENT, AND WIRING DEVICES AND ASSOCIATED WALL PLATE THROUGH ONE SOURCE FROM A SINGLE MANUFACTURER. SO FAR AS THEY ARE AVAILABLE, OBTAIN ALL PRODUCTS, EQUIPMENT, AND WIRING
DEVICES AND ASSOCIATED WALL PLATES FROM A SINGLE MANUFACTURER AND ONE SOURCE.
1.4 COORDINATION
COORDINATE ARRANGEMENT, MOUNTING, AND SUPPORT OF ELECTRICAL EQUIPMENT:
TO ALLOW MAXIMUM POSSIBLE HEADROOM UNLESS SPECIFIC MOUNTING HEIGHTS THAT REDUCE HEADROOM ARE INDICATED.
TO PROVIDE FOR EASE OF DISCONNECTING THE EQUIPMENT WITH MINIMUM INTERFERENCE TO OTHER INSTALLATIONS.
TO ALLOW RIGHT OF WAY FOR PIPING AND CONDUIT INSTALLED AT REQUIRED SLOPE.
SO CONNECTING RACEWAYS, CABLES, WIREWAYS, CABLE TRAYS, AND BUSWAYS WILL BE CLEAR OF OBSTRUCTIONS AND OF THE
WORKING AND ACCESS SPACE OF OTHER EQUIPMENT.
COORDINATE IDENTIFICATION NAMES, ABBREVIATIONS, COLORS, AND OTHER FEATURES WITH REQUIREMENTS IN THE CONTRACT DOCUMENTS, SHOP DRAWINGS, MANUFACTURER'S WIRING DIAGRAMS, AND THE OPERATION AND MAINTENANCE MANUAL, AND WITH THOSE REQUIRED BY CODES, STANDARDS, AND 29 CFR 1910.145. USE CONSISTENT DESIGNATIONS THROUGHOUT PROJECT.
RECEPTACLES FOR OWNER-FURNISHED EQUIPMENT: MATCH PLUG CONFIGURATIONS.
PART 2 - PRODUCTS
2.1 GROUNDING PRODUCTS
BONDING CONDUCTOR: NO. 6 AWG INSULATED COPPER, STRANDED CONDUCTOR.
WELDED CONNECTORS: EXOTHERMIC-WELDING KITS OF TYPES RECOMMENDED BY KIT MANUFACTURER FOR MATERIALS BEING
JOINED AND INSTALLATION CONDITIONS.
GROUND RODS: COPPER-CLAD STEEL 3/4 INCH BY 10 FEET.
2.2 RACEWAYS AND WIREWAYS
RACEWAY MATERIALS:
RIGID STEEL CONDUIT (RMC): ANSI C80.1.
EMT: ANSI C80.3.
LFMC: FLEXIBLE STEEL CONDUIT WITH PVC JACKET.
FITTINGS FOR CONDUIT (INCLUDING ALL TYPES AND FLEXIBLE AND LIQUIDTIGHT), EMT, AND CABLE. NEMA FB 1: LISTED FOR TYPE AND SIZE RACEWAY WITH WHICH USED, AND FOR APPLICATION AND ENVIRONMENT IN WHICH INSTALLED.
SURFACE RACEWAY: WIREMOLD SERIES 500/700 ONE PIECE RACEWAY
METAL WIREWAYS DESCRIPTION: SHEET METAL SIZED AND SHAPED AS INDICATED, NEMA 250, TYPE 1 OR 3R, UNLESS OTHERWISE
INDICATED. WIREWAY COVERS: SCREW-COVER TYPE OR AS INDICATED.
SHEET METAL OUTLET AND DEVICE BOXES: NEMA OS 1.
SMALL SHEET METAL PULL AND JUNCTION BOXES: NEMA OS 1.
CABINETS:
NEMA 250, TYPE 1, GALVANIZED-STEEL BOX WITH REMOVABLE INTERIOR PANEL AND REMOVABLE.
HINGED DOOR IN FRONT COVER WITH FLUSH LATCH AND CONCEALED HINGE.
KEY LATCH TO MATCH PANELBOARDS.
2.3 CABLES AND WIRING MATERIALS
CONDUCTOR INSULATION: COMPLY WITH NEMA WC 70 FOR TYPES THW AND THHN-THWN.
MULTICONDUCTOR CABLE: COMPLY WITH NEMA WC 70 FOR METAL-CLAD CABLE, TYPE MC WITH GROUND WIRE.
FEEDERS: COPPER, STRANDED
BRANCH CIRCUITS: COPPER, STRANDED, MINIMUM 12 AWG.
EXPOSED OR CONCEALED FEEDERS AND BRANCH CIRCUITS: TYPE THHN-THWN, SINGLE CONDUCTORS IN RACEWAY.
CLASS 1 CONTROL CIRCUITS: TYPE THHN-THWN, IN RACEWAY.
CLASS 2 CONTROL CIRCUITS: TYPE THHN-THWN, IN RACEWAY, OR POWER-LIMITED CABLE, CONCEALED IN BUILDING FINISHES.
2.4 IDENTIFICATION MATERIALS
COLOR-CODING CONDUCTOR TAPE: COLORED, SELF-ADHESIVE VINYL-TAPE NOT LESS THAN 3 MILS THICK BY 1 TO 2 INCHES WIDE.
MARKER TAPES: VINYL OR VINYL-CLOTH, SELF-ADHESIVE WRAPAROUND TYPE, WITH CIRCUIT IDENTIFICATION LEGEND MACHINE
PRINTED BY THERMAL TRANSFER OR EQUIVALENT PROCESS.
SELF-ADHESIVE, ENGRAVED, LAMINATED ACRYLIC OR MELAMINE LABEL. ADHESIVE BACKED, WITH WHITE LETTERS ON A DARK-GRAY
BACKGROUND. MINIMUM LETTER HEIGHT SHALL BE 3/8 INCH.
2.5 WIRING DEVICES
PROVIDE PRODUCTS BY ONE OF THE FOLLOWING MANUFACTURERS:
COOPER WIRING DEVICES: A DIVISION OF COOPER INDUSTRIES, INC.
HUBBELL INCORPORATED: WIRING DEVICE-KELLEMS.
LEVITON MFG. COMPANY, INC.
PASS & SEYMOUR/LEGRAND: WIRING DEVICES & ACCESSORIES.
GFCI DUPLEX RECEPTACLES: STRAIGHT BLADE, FEED-THROUGH TYPE. COMPLY WITH NEMA WD 1, NEMA WD 6, UL 498, AND UL 943, CLASS A, AND INCLUDE INDICATOR LIGHT THAT IS LIGHTED WHEN DEVICE IS TRIPPED.
SNAP SWITCHES: COMPLY WITH NEMA WD 1 AND UL 20, 120/277V, 20A.
WALL PLATES: SINGLE AND COMBINATION TYPES TO MATCH CORRESPONDING WIRING DEVICES.
PLATE-SECURING SCREWS: METAL WITH HEAD COLOR TO MATCH PLATE FINISH.
MATERIAL: SMOOTH, HIGH-IMPACT THERMOPLASTIC.
WET OR DAMP-LOCATION, WEATHERPROOF COVER PLATES: NEMA 250, COMPLYING WITH TYPE 3R WEATHER-RESISTANT, DIE-CAST
ALUMINUM WITH LOCKABLE COVER.
2.6 LIGHTING FIXTURES
SEE LIGHTING FIXTURE SCHEDULE ON THE DRAWINGS FOR PRODUCT SPECIFICATIONS.
2.7 LIGHTING CONTROLS
BASIS OF DESIGN IS ACUITY BRANDS. ALTERNATES MUST BE REVIEWED FOR APPROVAL DURING BIDDING. SEE REQUIREMENTS OF THE
DRAWINGS.
A.
B.
A.
B.
C.
A.
B.
1.
A.
2.
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
C.
D.
E.
F.
G.
H.
1.
2.
A.
B.
C.
3.
A.
B.
C.
4.
A.
B.
5.
A.
B.
C.
D.
A.
B.
C.
1.
2.
3.
4.
5.
D.
E.
1.
F.
G.
H.
I.
J.
K.
L.
M.
N.
1.
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
1.
K.
L.
A.
B.
A.
1.
2.
B.
1.
C.
PART 3 - EXECUTION
3.1 COMMON REQUIREMENTS FOR ELECTRICAL INSTALLATION
EQUIPMENT: INSTALL TO FACILITATE SERVICE, MAINTENANCE, AND REPAIR OR REPLACEMENT OF COMPONENTS OF BOTH ELECTRICAL EQUIPMENT AND OTHER NEARBY INSTALLATIONS. CONNECT IN SUCH A WAY AS TO FACILITATE FUTURE DISCONNECTING WITH MINIMUM
INTERFERENCE WITH OTHER ITEMS IN THE VICINITY.
RIGHT OF WAY: GIVE TO PIPING SYSTEMS INSTALLED AT A REQUIRED SLOPE.
3.2 GROUNDING APPLICATIONS
INSTALL INSULATED EQUIPMENT GROUNDING CONDUCTORS WITH ALL FEEDERS AND BRANCH CIRCUITS. INSULATION SHALL BE RATED AT 600V
OR AS APPROVED BY AUTHORITY HAVING JURISDICTION.
CONDUCTORS: INSTALL SOLID CONDUCTOR FOR NO. 10 AWG AND SMALLER, AND STRANDED CONDUCTORS FOR NO. 8 AWG AND LARGER, UNLESS OTHERWISE INDICATED.
METAL POLES FOR SIGNS SUPPORTING OUTDOOR LIGHTING FIXTURES: INSTALL GROUNDING ELECTRODE AND A SEPARATE INSULATED EQUIPMENT GROUNDING CONDUCTOR IN ADDITION TO GROUNDING CONDUCTOR INSTALLED WITH BRANCH-CIRCUIT CONDUCTORS.
3.3 APPLICATION OF IDENTIFICATION SYSTEMS
BRANCH-CIRCUIT CONDUCTOR IDENTIFICATION: WHERE THERE ARE CONDUCTORS FOR MORE THAN THREE BRANCH CIRCUITS IN SAME JUNCTION OR PULL BOX, USE COLOR-CODING CONDUCTOR TAPE. IDENTIFY EACH UNDERGROUND CONDUCTOR ACCORDING TO SOURCE AND
CIRCUIT NUMBER.
EQUIPMENT IDENTIFICATION LABELS: ON EACH UNIT OF EQUIPMENT, INSTALL UNIQUE DESIGNATION LABEL THAT IS CONSISTENT WITH WIRING DIAGRAMS, SCHEDULES, AND OPERATION AND MAINTENANCE MANUAL. APPLY LABELS TO DISCONNECT SWITCHES AND PROTECTION EQUIPMENT, CENTRAL OR SYSTEM. SYSTEMS INCLUDE POWER, LIGHTING, CONTROL, COMMUNICATION, SIGNAL, MONITORING, AND ALARM
SYSTEMS UNLESS EQUIPMENT IS PROVIDED WITH ITS OWN IDENTIFICATION.
LABELING INSTRUCTIONS:
INDOOR EQUIPMENT: ADHESIVE FIELD LABEL. UNLESS OTHERWISE INDICATED, PROVIDE A SINGLE LINE OF TEXT WITH 1/2-INCH-HIGH LETTERS ON 1-1/2-INCH-HIGH LABEL. WHERE 2 LINES OF TEXT ARE REQUIRED, USE LABELS 2 INCHES HIGH.
EQUIPMENT TO BE LABELED:
PANELBOARDS, ELECTRICAL CABINETS, AND ENCLOSURES.
ACCESS DOORS AND PANELS FOR CONCEALED ELECTRICAL ITEMS.
TRANSFORMERS.
DISCONNECT SWITCHES.
ENCLOSED CIRCUIT BREAKERS.
MOTOR STARTERS.
PUSH-BUTTON STATIONS.
CONTACTORS.
REMOTE-CONTROLLED SWITCHES, DIMMER MODULES, AND CONTROL DEVICES.
LIGHTING CONTROL EQUIPMENT.
VERIFY IDENTITY OF EACH ITEM BEFORE INSTALLING IDENTIFICATION PRODUCTS.
LOCATION: INSTALL IDENTIFICATION MATERIALS AND DEVICES AT LOCATIONS FOR MOST CONVENIENT VIEWING WITHOUT INTERFERENCE WITH
OPERATION AND MAINTENANCE OF EQUIPMENT.
APPLY IDENTIFICATION DEVICES TO SURFACES THAT REQUIRE FINISH AFTER COMPLETING FINISH WORK.
SELF-ADHESIVE IDENTIFICATION PRODUCTS: CLEAN SURFACES BEFORE APPLICATION, USING MATERIALS AND METHODS RECOMMENDED BY
MANUFACTURER OF IDENTIFICATION DEVICE.
SYSTEM IDENTIFICATION COLOR BANDING FOR RACEWAYS AND CABLES: EACH COLOR BAND SHALL COMPLETELY ENCIRCLE CABLE OR CONDUIT.
PLACE ADJACENT BANDS OF TWO-COLOR MARKINGS IN CONTACT, SIDE BY SIDE. LOCATE BANDS AT CHANGES IN DIRECTION, AT PENETRATIONS OF WALLS AND FLOORS, AT 50-FOOT MAXIMUM INTERVALS IN STRAIGHT RUNS, AND AT 25-FOOT MAXIMUM INTERVALS IN CONGESTED AREAS.
COLOR-CODING FOR PHASE AND VOLTAGE LEVEL IDENTIFICATION, 600V AND LESS: USE THE COLORS LISTED BELOW FOR UNGROUNDED
SERVICE, FEEDER, AND BRANCH-CIRCUIT CONDUCTORS.
COLOR SHALL BE FIELD APPLIED FOR CONDUCTORS OVER NO. 10 AWG.
COLORS FOR 480/277V CIRCUITS:
PHASE A: BROWN
PHASE B: ORANGE
PHASE C: YELLOW
COLORS FOR 120/208V CIRCUITS:
PHASE A: BLACK
PHASE B: RED
PHASE C: BLUE
COLORS FOR 120/240V CIRCUITS:
PHASE A: BLACK
PHASE B: RED
FIELD-APPLIED, COLOR-CODING CONDUCTOR TAPE: APPLY IN HALF-LAPPED TURNS FOR A MINIMUM DISTANCE OF 6 INCHES FROM TERMINAL POINTS AND IN BOXES WHERE SPLICES OR TAPS ARE MADE. APPLY LAST TWO TURNS OF TAPE WITH NO TENSION TO PREVENT POSSIBLE
UNWINDING. LOCATE BANDS TO AVOID OBSCURING FACTORY CABLE MARKINGS.
3.4 INSTALLATION OF POWER CONDUCTORS AND CABLES
CONCEAL CABLES IN FINISHED WALLS, CEILINGS, AND FLOORS, UNLESS OTHERWISE INDICATED.
USE MANUFACTURER-APPROVED PULLING COMPOUND OR LUBRICANT WHERE NECESSARY. COMPOUND USED MUST NOT DETERIORATE CONDUCTOR OR INSULATION. DO NOT EXCEED MANUFACTURER'S RECOMMENDED MAXIMUM PULLING TENSIONS AND SIDEWALL PRESSURE
VALUES.
USING PULLING MEANS, INCLUDING FISH TABLE, CABLE, ROPE, AND BASKET-WEAVE WIRE/CABLE GRIPS, THAT WILL NOT DAMAGE CABLES OR
RACEWAY.
WIRING AT OUTLETS: INSTALL CONDUCTOR AT EACH OUTLET, WITH AT LEAST 12 INCHES OF SLACK.
3.5 RACEWAY INSTALLATION AND APPLICATION
COMPLY WITH NECA 1 FOR INSTALLATION REQUIREMENTS APPLICABLE TO PRODUCTS SPECIFIED IN PART 2 EXCEPT WHERE REQUIREMENTS ON
DRAWINGS OR IN THIS ARTICLE ARE STRICTER.
SUPPORT RACEWAYS PER NEC - NFPA-70.
COMPLY WITH THE FOLLOWING INDOOR APPLICATIONS, UNLESS OTHERWISE INDICATED:
EXPOSED ON ACOUSTICAL BLOCK: METAL WIREMOLD.
EXPOSED, NOT SUBJECT TO PHYSICAL DAMAGE: EMT ABOVE 48".
CONCEALED IN CEILINGS AND INTERIOR WALLS AND PARTITIONS: EMT.
CONNECTION TO VIBRATING EQUIPMENT (INCLUDING TRANSFORMERS AND HYDRAULIC, PNEUMATIC, ELECTRIC SOLENOID, OR MOTOR-
DRIVEN EQUIPMENT): LFMC.
DAMP OR WET LOCATIONS: RIGID STEEL CONDUIT.
MINIMUM RACEWAY SIZE: 3/4-INCH TRADE SIZE.
RACEWAY FITTINGS: COMPATIBLE WITH RACEWAYS AND SUITABLE FOR USE AND LOCATION.
RIGID AND INTERMEDIATE STEEL CONDUIT: USE THREADED RIGID STEEL CONDUIT FITTINGS, UNLESS OTHERWISE INDICATED.
COMPLETE RACEWAY INSTALLATION BEFORE STARTING CONDUCTOR INSTALLATION.
ARRANGE STUB-UPS SO CURVED PORTIONS OF BENDS ARE NOT VISIBLE ABOVE THE FINISHED SLAB.
INSTALL NO MORE THAN THE EQUIVALENT OF THREE 90-DEGREE BENDS IN ANY CONDUIT RUN EXCEPT FOR COMMUNICATIONS CONDUITS, FOR
WHICH FEWER BENDS ARE ALLOWED.
CONCEAL CONDUIT AND EMT WITHIN FINISHED WALLS, CEILINGS, AND FLOORS, UNLESS OTHERWISE INDICATED.
RACEWAYS EMBEDDED IN SLABS: NOT ALLOWED.
THREADED CONDUIT JOINTS, EXPOSED TO WET, DAMP, CORROSIVE, OR OUTDOOR CONDITIONS: APPLY LISTED COMPOUND TO THREADS OF RACEWAY AND FITTINGS BEFORE MAKING UP JOINTS. FOLLOW COMPOUND MANUFACTURER'S WRITTEN INSTRUCTIONS.
RACEWAY TERMINATIONS AT LOCATIONS SUBJECT TO MOISTURE OR VIBRATION: USE INSULATING BUSHINGS TO PROTECT CONDUCTORS, INCLUDING CONDUCTORS SMALLER THAN NO. 4 AWG.
INSTALL PULL WIRES IN EMPTY RACEWAYS. USE POLYPROPYLENE OR MONOFILAMENT PLASTIC LINE WITH NOT LESS THAN 200-LB TENSILE
STRENGTH. LEAVE AT LEAST 12 INCHES OF SLACK AT EACH END OF PULL WIRE.
FLEXIBLE CONDUIT CONNECTIONS: USE MAXIMUM OF 72 INCHES OF FLEXIBLE CONDUIT FOR RECESSED AND SEMI-RECESSED LIGHTING FIXTURES, EQUIPMENT SUBJECT TO VIBRATION, NOISE TRANSMISSION, OR MOVEMENT; AND FOR TRANSFORMERS AND MOTORS.
USE LFMC IN DAMP OR WET LOCATIONS SUBJECT TO SEVERE PHYSICAL DAMAGE.
3.6 WIRING DEVICE INSTALLATION
REPLACE ALL DEVICES THAT HAVE BEEN IN TEMPORARY USE DURING CONSTRUCTION OR THAT SHOW SIGNS THAT THEY WERE INSTALLED
BEFORE BUILDING FINISHING OPERATIONS WERE COMPLETE.
KEEP EACH WIRING DEVICE IN ITS PACKAGE OR OTHERWISE PROTECTED UNTIL IT IS TIME TO CONNECT CONDUCTORS.
DO NOT REMOVE SURFACE PROTECTION, SUCH AS PLASTIC FILM AND SMUDGE COVERS, UNTIL THE LAST POSSIBLE MOMENT.
CONNECT DEVICES TO BRANCH CIRCUITS USING PIGTAILS THAT ARE NOT LESS THAN 6 INCHES IN LENGTH.
WHEN THERE IS A CHOICE, USE SIDE WIRING WITH BINDING-HEAD SCREW TERMINALS. WRAP SOLID CONDUCTOR TIGHTLY CLOCKWISE, 2/3 TO 3/4
OF THE WAY AROUND TERMINAL SCREW.
USE A TORQUE SCREWDRIVER WHEN A TORQUE IS RECOMMENDED OR REQUIRED BY THE MANUFACTURER.
WHEN CONDUCTORS LARGER THAN NO. 12 AWG ARE INSTALLED ON 15-A OR 20-A CIRCUITS, SPLICE NO. 12 PIGTAILS FOR DEVICE CONNECTIONS.
TIGHTEN UNUSED TERMINAL SCREWS ON THE DEVICE.
WHEN MOUNTING INTO METAL BOXES, REMOVE THE FIBER OR PLASTIC WASHERS USED TO HOLD DEVICE MOUNTING SCREWS IN YOKES, ALLOWING METAL-TO-METAL CONTACT.
RECEPTACLE ORIENTATION:
INSTALL GROUND PIN OF VERTICALLY MOUNTED RECEPTACLES UP, AND ON HORIZONTALLY MOUNTED RECEPTACLES TO THE RIGHT.
DEVICE PLATES: DO NOT USE OVERSIZED OR EXTRA-DEEP PLATES. REPAIR WALL FINISHES AND REMOUNT OUTLET BOXES WHEN STANDARD
DEVICE PLATES DO NOT FIT FLUSH OR DO NOT COVER ROUGH WALL OPENING.
ARRANGEMENT OF DEVICES: UNLESS OTHERWISE INDICATED, MOUNT FLUSH, WITH LONG DIMENSION VERTICAL AND WITH GROUNDING TERMINAL OF RECEPTACLES ON TOP. GROUP ADJACENT SWITCHES UNDER SINGLE, MULTIGANG WALL PLATES.
3.7 LIGHTING CONTROLS
CONDUCT PRE-INSTALLATION MEETING WITH THE SUPPLIER, PROGRAMMER, INSTALLER, AND OWNER TO REVIEW THE SYSTEM.
PERFORM POST VISIT FOR PROGRAMMING
3.8 FIELD QUALITY CONTROL
PREPARE FOR ACCEPTANCE TESTS AS FOLLOWS:
TEST INSULATION RESISTANCE FOR EACH PANELBOARD BUS, COMPONENT, CONNECTING SUPPLY, FEEDER, AND CONTROL CIRCUIT.
TEST CONTINUITY OF EACH CIRCUIT.
PERFORM THE FOLLOWING FIELD TESTS AND INSPECTIONS AND PREPARE TEST REPORTS:
CORRECT MALFUNCTIONING UNITS ON-SITE, WHERE POSSIBLE, AND RETEST TO DEMONSTRATE COMPLIANCE; OTHERWISE, REPLACE WITH
NEW UNITS AND RETEST.
PROVIDE OPERATION AND MAINTENANCE MANUALS FOR ALL EQUIPMENT. INCLUDE WARRANTY AND REPLACEMENT PART LIST.
W
IL
LI
AM
A . K
IB
BE
A
SS
O
C
IA
TE
S, IN
C
E
N G
IN
E
E R
S
A R
C H
IT
E
C
TS
S
U R
V E
Y O
R S
PR
IN
TE
D:
SHEET
PROJ #:
DRAWN BY:
DES'D BY:
CHCK'D BY:
/8/
2:
:32 P
M
25-0543-0153
B. KUSHION
B. KUSHION
E. MARTER
SP
EC
IF
IC
AT
IO
NS
DE
LT
A
CO
LL
EG
E
S- W
IN
G
CO
RR
ID
OR
LI
GH
TI
NG
E0.1
©2
7 - A
LL
R
IG
HT
S
RE
SE
RV
ED
. T
HI
S
DO
CU
ME
NT
A
ND
D
ES
IG
NS
P
OR
TR
AY
ED
W
IT
HI
N
AR
E
TH
E
PR
OP
ER
TY
O
F W
AK
, N
O
MO
DI
FI
CA
TI
ON
S
AN
D/
OR
T
RA
NS
FE
RS
O F
W
OR
K
AR
E
PE
RM
IT
TE
D
UN
LE
SS
G
RA
NT
ED
B
Y W
AK
UN
IV
ER
SI
TY
C
EN
TE
R
MI
NO
ST
AT
US
/ R
EV
IS
IO
NS
DA
TE
IS
SU
ED
F
OR
B
ID
S
-0
8-
A.
1.
2.
3.
4.
5.
6.
7.
8.
9.
B.
1.
2.
3.
4.
5.
C.
1.
2.
3.
4.
D.
A.
B.
C.
A.
1.
2.
3.
B.
C.
024119 SELECTIVE DEMOLITION (CONT)
3.4 SELECTIVE DEMOLITION, GENERAL
GENERAL: DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT
REQUIRED BY NEW CONSTRUCTION AND AS INDICATED. USE METHODS REQUIRED TO
COMPLETE THE WORK WITHIN LIMITATIONS OF GOVERNING REGULATIONS AND AS
FOLLOWS:
PROCEED WITH SELECTIVE DEMOLITION SYSTEMATICALLY, FROM HIGHER TO
LOWER LEVEL.
NEATLY CUT OPENINGS AND HOLES PLUMB, SQUARE, AND TRUE TO
DIMENSIONS REQUIRED. USE CUTTING METHODS LEAST LIKELY TO DAMAGE
CONSTRUCTION TO REMAIN OR ADJOINING CONSTRUCTION. USE HAND TOOLS
OR SMALL POWER TOOLS DESIGNED FOR SAWING OR GRINDING, NOT
HAMMERING AND CHOPPING, TO MINIMIZE DISTURBANCE OF ADJACENT
SURFACES.
CUT OR DRILL FROM THE EXPOSED OR FINISHED SIDE INTO CONCEALED
SURFACES TO AVOID MARRING EXISTING FINISHED SURFACES.
DO NOT USE CUTTING TORCHES UNTIL WORK AREA IS CLEARED OF
FLAMMABLE MATERIALS. AT CONCEALED SPACES, SUCH AS DUCT AND PIPE
INTERIORS, VERIFY CONDITION AND CONTENTS OF HIDDEN SPACE BEFORE
STARTING FLAME-CUTTING OPERATIONS. MAINTAIN FIRE WATCH AND
PORTABLE FIRE-SUPPRESSION DEVICES DURING FLAME-CUTTING
OPERATIONS.
MAINTAIN ADEQUATE VENTILATION WHEN USING CUTTING TORCHES.
REMOVE DECAYED, VERMIN-INFESTED, OR OTHERWISE DANGEROUS OR
UNSUITABLE MATERIALS AND PROMPTLY DISPOSE OF OFF-SITE.
REMOVE STRUCTURAL FRAMING MEMBERS AND LOWER TO GROUND BY
METHOD SUITABLE TO AVOID FREE FALL AND TO PREVENT GROUND IMPACT
OR DUST GENERATION.
LOCATE SELECTIVE DEMOLITION EQUIPMENT AND REMOVE DEBRIS AND
MATERIALS SO AS NOT TO IMPOSE EXCESSIVE LOADS ON SUPPORTING
WALLS, FLOORS, OR FRAMING.
DISPOSE OF DEMOLISHED ITEMS AND MATERIALS PROMPTLY. SITE ACCESS
AND TEMPORARY CONTROLS: CONDUCT SELECTIVE DEMOLITION AND DEBRIS-
REMOVAL OPERATIONS TO ENSURE MINIMUM INTERFERENCE WITH ROADS,
STREETS, WALKS, WALKWAYS, AND OTHER ADJACENT OCCUPIED AND USED
FACILITIES.
REMOVED AND SALVAGED ITEMS:
CLEAN SALVAGED ITEMS.
PACK OR CRATE ITEMS AFTER CLEANING. IDENTIFY CONTENTS OF
CONTAINERS.
STORE ITEMS IN A SECURE AREA UNTIL DELIVERY TO OWNER.
TRANSPORT ITEMS TO OWNER'S STORAGE AREA ON-SITE.
PROTECT ITEMS FROM DAMAGE DURING TRANSPORT AND STORAGE.
REMOVED AND REINSTALLED ITEMS:
CLEAN AND REPAIR ITEMS TO FUNCTIONAL CONDITION ADEQUATE FOR
INTENDED REUSE.
PACK OR CRATE ITEMS AFTER CLEANING AND REPAIRING. IDENTIFY
CONTENTS OF CONTAINERS.
PROTECT ITEMS FROM DAMAGE DURING TRANSPORT AND STORAGE.
REINSTALL ITEMS IN LOCATIONS INDICATED. COMPLY WITH INSTALLATION
REQUIREMENTS FOR NEW MATERIALS AND EQUIPMENT. PROVIDE
CONNECTIONS, SUPPORTS, AND MISCELLANEOUS MATERIALS NECESSARY TO
MAKE ITEM FUNCTIONAL FOR USE INDICATED.
EXISTING ITEMS TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN
AGAINST DAMAGE AND SOILING DURING SELECTIVE DEMOLITION. WHEN PERMITTED
BY ARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE, PROTECTED STORAGE
LOCATION DURING SELECTIVE DEMOLITION , CLEANED AND REINSTALLED IN THEIR
ORIGINAL LOCATIONS AFTER SELECTIVE DEMOLITION OPERATIONS ARE COMPLETE.
3.5 SELECTIVE DEMOLITION PROCEDURES FOR SPECIFIC MATERIALS
CONCRETE SLABS-ON-GRADE: SAW-CUT PERIMETER OF AREA TO BE DEMOLISHED,
THEN BREAK UP AND REMOVE.
CONCRETE: DEMOLISH IN SECTIONS. CUT CONCRETE FULL DEPTH AT JUNCTURES
WITH CONSTRUCTION TO REMAIN AND AT REGULAR INTERVALS USING POWER-
DRIVEN SAW, THEN REMOVE CONCRETE BETWEEN SAW CUTS.
MASONRY: DEMOLISH IN SMALL SECTIONS. CUT MASONRY AT JUNCTURES WITH
CONSTRUCTION TO REMAIN, USING POWER-DRIVEN SAW, AND THEN REMOVE
MASONRY BETWEEN SAW CUTS.
3.6 DISPOSAL OF DEMOLISHED MATERIALS
GENERAL: EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE RECYCLED, REUSED,
SALVAGED, REINSTALLED, OR OTHERWISE INDICATED TO REMAIN OWNER'S
PROPERTY, REMOVE DEMOLISHED MATERIALS FROM PROJECT SITE AND LEGALLY
DISPOSE OF THEM IN AN EPA-APPROVED LANDFILL.
DO NOT ALLOW DEMOLISHED MATERIALS TO ACCUMULATE ON-SITE.
REMOVE AND TRANSPORT DEBRIS IN A MANNER THAT WILL PREVENT
SPILLAGE ON ADJACENT SURFACES AND AREAS.
REMOVE DEBRIS FROM ELEVATED PORTIONS OF BUILDING BY CHUTE, HOIST,
OR OTHER DEVICE THAT WILL CONVEY DEBRIS TO GRADE LEVEL IN A
CONTROLLED DESCENT.
BURNING: DO NOT BURN DEMOLISHED MATERIALS.
DISPOSAL: TRANSPORT DEMOLISHED MATERIALS OFF OWNER'S PROPERTY AND
LEGALLY DISPOSE OF THEM.
A.
A.
B.
1.
2.
3.
4.
C.
D.
A.
B.
1.
C.
D.
1.
E.
A.
A.
B.
A.
B.
C.
D.
E.
1.
F.
1.
A.
1.
B.
1.
2.
3.
4.
a.
b.
c.
d.
e.
f.
g.
A.
1.
B.
1.
2.
3.
4.
024119 SELECTIVE DEMOLITION
1.1 MATERIALS OWNERSHIP
UNLESS OTHERWISE INDICATED, DEMOLITION WASTE BECOMES PROPERTY OF
CONTRACTOR.
1.2 INFORMATIONAL SUBMITTALS
PROPOSED PROTECTION MEASURES: SUBMIT REPORT, INCLUDING DRAWINGS, THAT
INDICATES THE MEASURES PROPOSED FOR PROTECTING INDIVIDUALS AND
PROPERTY, FOR ENVIRONMENTAL PROTECTION, FOR DUST CONTROL AND, FOR
NOISE CONTROL. INDICATE PROPOSED LOCATIONS AND CONSTRUCTION OF
BARRIERS.
SCHEDULE OF SELECTIVE DEMOLITION ACTIVITIES: INDICATE THE FOLLOWING:
DETAILED SEQUENCE OF SELECTIVE DEMOLITION AND REMOVAL WORK, WITH
STARTING AND ENDING DATES FOR EACH ACTIVITY. ENSURE OWNER'S ON-
SITE OPERATIONS ARE UNINTERRUPTED.
INTERRUPTION OF UTILITY SERVICES. INDICATE HOW LONG UTILITY SERVICES
WILL BE INTERRUPTED.
COORDINATION FOR SHUTOFF, CAPPING, AND CONTINUATION OF UTILITY
SERVICES.
COORDINATION OF OWNER'S CONTINUING OCCUPANCY OF PORTIONS OF
EXISTING SITE AND OF OWNER'S PARTIAL OCCUPANCY OF COMPLETED WORK.
SEE SECTION 010100, SUMMARY OF WORK.
INVENTORY: SUBMIT A LIST OF ITEMS TO BE REMOVED AND SALVAGED AND DELIVER
TO OWNER PRIOR TO START OF DEMOLITION.
PRE-DEMOLITION PHOTOGRAPHS OR VIDEO: SUBMIT BEFORE WORK BEGINS.
1.3 FIELD CONDITIONS
NOTIFY ARCHITECT OF DISCREPANCIES BETWEEN EXISTING CONDITIONS AND
DRAWINGS BEFORE PROCEEDING WITH SELECTIVE DEMOLITION.
HAZARDOUS MATERIALS: IT IS NOT EXPECTED THAT HAZARDOUS MATERIALS WILL BE
ENCOUNTERED IN THE WORK.
IF SUSPECTED HAZARDOUS MATERIALS ARE ENCOUNTERED, DO NOT
DISTURB; IMMEDIATELY NOTIFY ARCHITECT AND OWNER. HAZARDOUS
MATERIALS WILL BE REMOVED BY OWNER UNDER A SEPARATE CONTRACT.
STORAGE OR SALE OF REMOVED ITEMS OR MATERIALS ON-SITE IS NOT PERMITTED.
UTILITY SERVICE: MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN IN SERVICE
AND PROTECT THEM AGAINST DAMAGE DURING SELECTIVE DEMOLITION
OPERATIONS.
MAINTAIN FIRE-PROTECTION FACILITIES IN SERVICE DURING SELECTIVE
DEMOLITION OPERATIONS.
ARRANGE SELECTIVE DEMOLITION SCHEDULE SO AS NOT TO INTERFERE WITH
OWNER'S OPERATIONS.
1.4 WARRANTY
EXISTING WARRANTIES: REMOVE, REPLACE, PATCH, AND REPAIR MATERIALS AND
SURFACES CUT OR DAMAGED DURING SELECTIVE DEMOLITION, BY METHODS AND
WITH MATERIALS AND USING APPROVED CONTRACTORS SO AS NOT TO VOID
EXISTING WARRANTIES.
2.1 PERFORMANCE CRITERIA
REGULATORY REQUIREMENTS: COMPLY WITH GOVERNING EPA NOTIFICATION
REGULATIONS BEFORE BEGINNING SELECTIVE DEMOLITION. COMPLY WITH HAULING
AND DISPOSAL REGULATIONS OF AUTHORITIES HAVING JURISDICTION.
STANDARDS: COMPLY WITH ASSE A10.6 AND NFPA 241.
3.1 EXAMINATION
VERIFY THAT UTILITIES HAVE BEEN DISCONNECTED AND CAPPED BEFORE STARTING
SELECTIVE DEMOLITION OPERATIONS.
REVIEW RECORD DOCUMENTS OF EXISTING CONSTRUCTION PROVIDED BY OWNER.
OWNER DOES NOT GUARANTEE THAT EXISTING CONDITIONS ARE SAME AS THOSE
INDICATED IN RECORD DOCUMENTS.
SURVEY EXISTING CONDITIONS AND CORRELATE WITH REQUIREMENTS INDICATED
TO DETERMINE EXTENT OF SELECTIVE DEMOLITION REQUIRED.
WHEN UNANTICIPATED MECHANICAL, ELECTRICAL, OR STRUCTURAL ELEMENTS THAT
CONFLICT WITH INTENDED FUNCTION OR DESIGN ARE ENCOUNTERED, INVESTIGATE
AND MEASURE THE NATURE AND EXTENT OF CONFLICT. PROMPTLY SUBMIT A
WRITTEN REPORT TO ARCHITECT.
ENGAGE A PROFESSIONAL ENGINEER TO PERFORM AN ENGINEERING SURVEY OF
CONDITION OF SITE TO DETERMINE WHETHER REMOVING ANY ELEMENT MIGHT
RESULT IN STRUCTURAL DEFICIENCY OR UNPLANNED COLLAPSE OF ANY PORTION
OF STRUCTURE OR ADJACENT STRUCTURES DURING SELECTIVE BUILDING
DEMOLITION OPERATIONS.
PERFORM SURVEYS AS THE WORK PROGRESSES TO DETECT HAZARDS
RESULTING FROM SELECTIVE DEMOLITION ACTIVITIES.
SURVEY OF EXISTING CONDITIONS: RECORD EXISTING CONDITIONS BY USE OF
MEASURED DRAWINGS, PRECONSTRUCTION PHOTOGRAPHS, PRECONSTRUCTION
VIDEOTAPES, AND TEMPLATES.
INVENTORY AND RECORD THE CONDITION OF ITEMS TO BE REMOVED AND
SALVAGED. PROVIDE PHOTOGRAPHS OR VIDEO OF CONDITIONS THAT MIGHT
BE MISCONSTRUED AS DAMAGE CAUSED BY SALVAGE OPERATIONS.
3.2 UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEMS
EXISTING SERVICES/SYSTEMS TO REMAIN: MAINTAIN SERVICES/SYSTEMS INDICATED
TO REMAIN AND PROTECT THEM AGAINST DAMAGE.
COMPLY WITH REQUIREMENTS FOR EXISTING SERVICES/SYSTEMS
INTERRUPTIONS SPECIFIED IN DIVISION 01 SECTION "SUMMARY."
EXISTING SERVICES/SYSTEMS TO BE REMOVED, RELOCATED, OR ABANDONED:
LOCATE, IDENTIFY, DISCONNECT, AND SEAL OR CAP OFF UTILITY SERVICES AND
MECHANICAL/ELECTRICAL SYSTEMS SERVING AREAS TO BE SELECTIVELY
DEMOLISHED.
OWNER WILL ARRANGE TO SHUT OFF INDICATED SERVICES/SYSTEMS WHEN
REQUESTED BY CONTRACTOR.
ARRANGE TO SHUT OFF UTILITIES WITH UTILITY COMPANIES.
IF SERVICES/SYSTEMS ARE REQUIRED TO BE REMOVED, RELOCATED, OR
ABANDONED, PROVIDE TEMPORARY SERVICES/SYSTEMS THAT BYPASS AREA
OF SELECTIVE DEMOLITION AND THAT MAINTAIN CONTINUITY OF
SERVICES/SYSTEMS.
DISCONNECT, DEMOLISH, AND REMOVE FIRE-SUPPRESSION SYSTEMS,
PLUMBING, AND HVAC SYSTEMS, EQUIPMENT, AND COMPONENTS INDICATED
ON DRAWINGS TO BE REMOVED.
PIPING TO BE REMOVED: REMOVE PORTION OF PIPING INDICATED TO
BE REMOVED AND CAP OR PLUG REMAINING PIPING WITH SAME OR
COMPATIBLE PIPING MATERIAL.
PIPING TO BE ABANDONED IN PLACE: DRAIN PIPING AND CAP OR PLUG
PIPING WITH SAME OR COMPATIBLE PIPING MATERIAL.
EQUIPMENT TO BE REMOVED: DISCONNECT AND CAP SERVICES AND
REMOVE EQUIPMENT.
EQUIPMENT TO BE REMOVED AND REINSTALLED: DISCONNECT AND
CAP SERVICES AND REMOVE, CLEAN, AND STORE EQUIPMENT; WHEN
APPROPRIATE, REINSTALL, RECONNECT, AND MAKE EQUIPMENT
OPERATIONAL.
EQUIPMENT TO BE REMOVED AND SALVAGED: DISCONNECT AND CAP
SERVICES AND REMOVE EQUIPMENT AND DELIVER TO OWNER.
DUCTS TO BE REMOVED: REMOVE PORTION OF DUCTS INDICATED TO
BE REMOVED AND PLUG REMAINING DUCTS WITH SAME OR
COMPATIBLE DUCTWORK MATERIAL.
DUCTS TO BE ABANDONED IN PLACE: CAP OR PLUG DUCTS WITH SAME
OR COMPATIBLE DUCTWORK MATERIAL AND LEAVE IN PLACE.
3.3 PREPARATION
SITE ACCESS AND TEMPORARY CONTROLS: CONDUCT SELECTIVE DEMOLITION AND
DEBRIS-REMOVAL OPERATIONS TO ENSURE MINIMUM INTERFERENCE WITH ROADS,
STREETS, WALKS, WALKWAYS, AND OTHER ADJACENT OCCUPIED AND USED
FACILITIES.
COMPLY WITH REQUIREMENTS FOR ACCESS AND PROTECTION SPECIFIED IN
DIVISION 01 SECTION "TEMPORARY FACILITIES AND CONTROLS."
TEMPORARY FACILITIES: PROVIDE TEMPORARY BARRICADES AND OTHER
PROTECTION REQUIRED TO PREVENT INJURY TO PEOPLE AND DAMAGE TO
ADJACENT BUILDINGS AND FACILITIES TO REMAIN.
PROVIDE PROTECTION TO ENSURE SAFE PASSAGE OF PEOPLE AROUND
SELECTIVE DEMOLITION AREA AND TO AND FROM OCCUPIED PORTIONS OF
BUILDING.
PROVIDE TEMPORARY WEATHER PROTECTION, DURING INTERVAL BETWEEN
SELECTIVE DEMOLITION OF EXISTING CONSTRUCTION ON EXTERIOR
SURFACES AND NEW CONSTRUCTION, TO PREVENT WATER LEAKAGE AND
DAMAGE TO STRUCTURE AND INTERIOR AREAS.
PROTECT WALLS, CEILINGS, FLOORS, AND OTHER EXISTING FINISH WORK
THAT ARE TO REMAIN OR THAT ARE EXPOSED DURING SELECTIVE
DEMOLITION OPERATIONS.
COMPLY WITH REQUIREMENTS FOR TEMPORARY ENCLOSURES, DUST
CONTROL, HEATING, AND COOLING SPECIFIED IN DIVISION 01 SECTION
"TEMPORARY FACILITIES AND CONTROLS."
OS
OS OS
OS
OS
OS
OS OS
OS
OS
MATCH LINE
THIS SHEET
MATCH LINE
THIS SHEET
MATCH LINE
THIS SHEET
MATCH LINE
THIS SHEET
W
IL
LI
AM
A . K
IB
BE
A
SS
O
C
IA
TE
S, IN
C
E
N G
IN
E
E R
S
A R
C H
IT
E
C
TS
S
U R
V E
Y O
R S
PR
IN
TE
D:
SHEET
PROJ #:
DRAWN BY:
DES'D BY:
CHCK'D BY:
/8/
2:
:33 P
M
25-0543-0153
B. KUSHION
B. KUSHION
E. MARTER
S- W
IN
G
LO
W
ER
LE
VE
L L
IG
HT
IN
G
DE
MO
LIT
IO
N
PL
AN
DE
LT
A
CO
LL
EG
E S-
W
IN
G
CO
RR
ID
OR
LI
GH
TI
NG
E1.0
©2
7 - A
LL
R
IG
HT
S
RE
SE
RV
ED
. T
HI
S
DO
CU
ME
NT
A
ND
D
ES
IG
NS
P
OR
TR
AY
ED
W
IT
HI
N
AR
E
TH
E
PR
OP
ER
TY
O
F W
AK
, N
O
MO
DI
FI
CA
TI
ON
S
AN
D/
OR
T
RA
NS
FE
RS
O F
W
OR
K
AR
E
PE
RM
IT
TE
D
UN
LE
SS
G
RA
NT
ED
B
Y W
AK
UN
IV
ER
SI
TY
C
EN
TE
R
MI
N E1.0 SCALE: 1/8" = 1'-0"
S-WING LOWER LEVEL LIGHTING DEMOLITION PLAN1
SYMBOL DESCRIPTION
KEYED DEMOLITION NOTES
1 DISCONNECT AND REMOVE ALL
SURFACE MOUNTED STRIP LIGHTS IN
RECESSED SOFFIT & EGG CRATE
DIFFUSERS. SALVAGE CIRCUITS AND
CONTROLS TO BE USED WITH NEW
LIGHTS.
2 VERIFY EMERGENCY LIGHTING CIRCUIT,
DISCONNECT AND REMOVE SURFACE
MOUNTED STRIP LIGHTS IN RECESSED
SOFFIT. SALVAGE EMERGENCY LIGHTING
CIRCUITS TO BE USED WITH NEW
LIGHTS.
3 DISCONNECT AND REMOVE LIGHTING.
SALVAGE CIRCUITS AND CONTROLS TO
BE USED WITH NEW LIGHTS.
4 DISCONNECT AND REMOVE LINEAR
PENDANT MOUNT LIGHTING. SALVAGE
CIRCUIT TO BE USED WITH NEW LIGHTS.
5 DISCONNECT AND REMOVE EXISTING
LIGHTING CONTROLS. SALVAGE
LOCATIONS FOR NEW CONTROLS.
NO
ST
AT
US
/ R
EV
IS
IO
NS
DA
TE
O W
NE
R
RE
VI
EW
-2 8-
O
W
NE
R
RE
VI
EW
-0
3-
IS
SU
ED
F
OR
B
ID
S
-0
First Floor - Ceiling Grid
110°
FE FEC
FE
OS
OS
OS
First Floor - Ceiling Grid
110°
FE FEC
FE
OS
OS
OS
OS
MATCH LINE
THIS SHEET
MATCH LINE
THIS SHEET
MATCH LINE
THIS SHEET
MATCH LINE
THIS SHEET
W
IL
LI
AM
A . K
IB
BE
A
SS
O
C
IA
TE
S, IN
C
E
N G
IN
E
E R
S
A R
C H
IT
E
C
TS
S
U R
V E
Y O
R S
PR
IN
TE
D:
SHEET
PROJ #:
DRAWN BY:
DES'D BY:
CHCK'D BY:
/8/
2:
:34 P
M
25-0543-0153
B. KUSHION
B. KUSHION
E. MARTER
S- W
IN
G
FI
RS
T
FL
OO
R
LIG
HT
IN
G
DE
MO
LIT
IO
N
PL
AN
DE
LT
A
CO
LL
EG
E S-
W
IN
G
CO
RR
ID
OR
LI
GH
TI
NG
E1.1
©2
7 - A
LL
R
IG
HT
S
RE
SE
RV
ED
. T
HI
S
DO
CU
ME
NT
A
ND
D
ES
IG
NS
P
OR
TR
AY
ED
W
IT
HI
N
AR
E
TH
E
PR
OP
ER
TY
O
F W
AK
, N
O
MO
DI
FI
CA
TI
ON
S
AN
D/
OR
T
RA
NS
FE
RS
O F
W
OR
K
AR
E
PE
RM
IT
TE
D
UN
LE
SS
G
RA
NT
ED
B
Y W
AK
UN
IV
ER
SI
TY
C
EN
TE
R
MI
N E1.1 SCALE: 1/8" = 1'-0"
S-WING FIRST FLOOR LIGHTING DEMOLITION1
SYMBOL DESCRIPTION
KEYED DEMOLITION NOTES
1 DISCONNECT AND REMOVE ALL
SURFACE MOUNTED STRIP LIGHTS IN
RECESSED SOFFIT & EGG CRATE
DIFFUSERS. SALVAGE CIRCUITS AND
CONTROLS TO BE USED WITH NEW
LIGHTS.
2 VERIFY EMERGENCY LIGHTING CIRCUIT,
DISCONNECT AND REMOVE SURFACE
MOUNTED STRIP LIGHTS IN RECESSED
SOFFIT. SALVAGE EMERGENCY LIGHTING
CIRCUITS TO BE USED WITH NEW
LIGHTS.
3 DISCONNECT AND REMOVE LIGHTING.
SALVAGE CIRCUITS AND CONTROLS TO
BE USED WITH NEW LIGHTS.
4 DISCONNECT AND REMOVE LINEAR
PENDANT MOUNT LIGHTING. SALVAGE
CIRCUIT TO BE USED WITH NEW LIGHTS.
5 DISCONNECT AND REMOVE EXISTING
LIGHTING CONTROLS. SALVAGE
LOCATIONS FOR NEW CONTROLS.
NO
ST
AT
US
/ R
EV
IS
IO
NS
DA
TE
O W
NE
R
RE
VI
EW
-2 8-
O
W
NE
R
RE
VI
EW
-0
3-
IS
SU
ED
F
OR
B
ID
S
-0
Second Floor - Master Plan
OS
OS
OS
OS
OS
OS
OS
Second Floor - Master Plan
MATCH LINE
THIS SHEET
MATCH LINE
THIS SHEET
MATCH LINE
THIS SHEET
MATCH LINE
THIS SHEET
2 2
W
IL
LI
AM
A . K
IB
BE
A
SS
O
C
IA
TE
S, IN
C
E
N G
IN
E
E R
S
A R
C H
IT
E
C
TS
S
U R
V E
Y O
R S
PR
IN
TE
D:
SHEET
PROJ #:
DRAWN BY:
DES'D BY:
CHCK'D BY:
/8/
2:
:35 P
M
25-0543-0153
B. KUSHION
B. KUSHION
E. MARTER
S- W
IN
G
SE
CO
ND
F
LO
OR
LI
GH
TI
NG
DE
MO
LIT
IO
N
PL
AN
DE
LT
A
CO
LL
EG
E S-
W
IN
G
CO
RR
ID
OR
LI
GH
TI
NG
E1.2
©2
7 - A
LL
R
IG
HT
S
RE
SE
RV
ED
. T
HI
S
DO
CU
ME
NT
A
ND
D
ES
IG
NS
P
OR
TR
AY
ED
W
IT
HI
N
AR
E
TH
E
PR
OP
ER
TY
O
F W
AK
, N
O
MO
DI
FI
CA
TI
ON
S
AN
D/
OR
T
RA
NS
FE
RS
O F
W
OR
K
AR
E
PE
RM
IT
TE
D
UN
LE
SS
G
RA
NT
ED
B
Y W
AK
UN
IV
ER
SI
TY
C
EN
TE
R
MI
N E1.2 SCALE: 1/8" = 1'-0"
S-WING SECOND FLOOR LIGHTING DEMOLITION1
SYMBOL DESCRIPTION
KEYED DEMOLITION NOTES
1 DISCONNECT AND REMOVE ALL
SURFACE MOUNTED STRIP LIGHTS IN
RECESSED SOFFIT & EGG CRATE
DIFFUSERS. SALVAGE CIRCUITS AND
CONTROLS TO BE USED WITH NEW
LIGHTS.
2 VERIFY EMERGENCY LIGHTING CIRCUIT,
DISCONNECT AND REMOVE SURFACE
MOUNTED STRIP LIGHTS IN RECESSED
SOFFIT. SALVAGE EMERGENCY LIGHTING
CIRCUITS TO BE USED WITH NEW
LIGHTS.
3 DISCONNECT AND REMOVE LIGHTING.
SALVAGE CIRCUITS AND CONTROLS TO
BE USED WITH NEW LIGHTS.
4 DISCONNECT AND REMOVE LINEAR
PENDANT MOUNT LIGHTING. SALVAGE
CIRCUIT TO BE USED WITH NEW LIGHTS.
5 DISCONNECT AND REMOVE EXISTING
LIGHTING CONTROLS. SALVAGE
LOCATIONS FOR NEW CONTROLS.
NO
ST
AT
US
/ R
EV
IS
IO
NS
DA
TE
O W
NE
R
RE
VI
EW
-2 8-
O
W
NE
R
RE
VI
EW
-0
3-
IS
SU
ED
F
OR
B
ID
S
-0
OS OS
OS
OS
OS
OS OS
OS
OS
MATCH LINE
THIS SHEET
MATCH LINE
THIS SHEET
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B B
BB B B
BB
BB
B B
B B
B B
2 2
2 2
E8.0
MATCH LINE
THIS SHEET
MATCH LINE
THIS SHEET
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
BB
B
W
IL
LI
AM
A . K
IB
BE
A
SS
O
C
IA
TE
S, IN
C
E
N G
IN
E
E R
S
A R
C H
IT
E
C
TS
S
U R
V E
Y O
R S
PR
IN
TE
D:
SHEET
PROJ #:
DRAWN BY:
DES'D BY:
CHCK'D BY:
/8/
2:
:35 P
M
25-0543-0153
B. KUSHION
B. KUSHION
E. MARTER
S- W
IN
G
LO
W
ER
LE
VE
L L
IG
HT
IN
G
PL
AN
DE
LT
A
CO
LL
EG
E S-
W
IN
G
CO
RR
ID
OR
LI
GH
TI
NG
E3.0
©2
7 - A
LL
R
IG
HT
S
RE
SE
RV
ED
. T
HI
S
DO
CU
ME
NT
A
ND
D
ES
IG
NS
P
OR
TR
AY
ED
W
IT
HI
N
AR
E
TH
E
PR
OP
ER
TY
O
F W
AK
, N
O
MO
DI
FI
CA
TI
ON
S
AN
D/
OR
T
RA
NS
FE
RS
O F
W
OR
K
AR
E
PE
RM
IT
TE
D
UN
LE
SS
G
RA
NT
ED
B
Y W
AK
UN
IV
ER
SI
TY
C
EN
TE
R
MI
N E3.0 SCALE: 1/8" = 1'-0"
S-WING LOWER LEVEL LIGHTING PLAN1
SYMBOL DESCRIPTION
KEYED CONSTRUCTION NOTES
1 CONNECT NEW LIGHT FIXTURE TO
EMERGENCY LIGHTING CIRCUIT.
2 INSTALL NEW LIGHT FIXTURES IN
EXISTING CEILING & CONNECT TO
SALVAGED CIRCUIT. PROVIDE CEILING
TILES & GRID AS NECESSARY TO
COMPLETE THE CEILING INSTALLATION.
3 PROVIDE RCMS PDT 9 AR G2
OCCUPANCY SENSOR WITH RPP20 D 24V
EFP G2 POWER PACK.
4 PROVIDE RPODLA DX MVOLT WH G2 LINE
POWERED WALL SWITCH.
NO
ST
AT
US
/ R
EV
IS
IO
NS
DA
TE
O W
NE
R
RE
VI
EW
-2 8-
O
W
NE
R
RE
VI
EW
-0
3-
IS
SU
ED
F
OR
B
ID
S
-0
8-
GENERAL NOTE:
REFER TO DETAIL ONE ON SHEET
E8.0 FOR TYPICAL CEILING & LIGHT
FIXTURE MODIFICATION DETAIL
NEW CEILING TILES & GRID TO
MATCH EXISTING
First Floor - Ceiling Grid
110°
FE FEC
FE
OS
OS
OS
OS
First Floor - Ceiling Grid
110°
FE FEC
FE
OS
OS
OS
MATCH LINE
THIS SHEET
MATCH LINE
THIS SHEET
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
1 1
MATCH LINE
THIS SHEET
MATCH LINE
THIS SHEET
C
C
C
C
C
C
C
C
C
C
C
C
W
IL
LI
AM
A . K
IB
BE
A
SS
O
C
IA
TE
S, IN
C
E
N G
IN
E
E R
S
A R
C H
IT
E
C
TS
S
U R
V E
Y O
R S
PR
IN
TE
D:
SHEET
PROJ #:
DRAWN BY:
DES'D BY:
CHCK'D BY:
/8/
2:
:36 P
M
25-0543-0153
B. KUSHION
B. KUSHION
E. MARTER
S- W
IN
G
FI
RS
T
FL
OO
R
LIG
HT
IN
G
PL
AN
DE
LT
A
CO
LL
EG
E S-
W
IN
G
CO
RR
ID
OR
LI
GH
TI
NG
E3.1
©2
7 - A
LL
R
IG
HT
S
RE
SE
RV
ED
. T
HI
S
DO
CU
ME
NT
A
ND
D
ES
IG
NS
P
OR
TR
AY
ED
W
IT
HI
N
AR
E
TH
E
PR
OP
ER
TY
O
F W
AK
, N
O
MO
DI
FI
CA
TI
ON
S
AN
D/
OR
T
RA
NS
FE
RS
O F
W
OR
K
AR
E
PE
RM
IT
TE
D
UN
LE
SS
G
RA
NT
ED
B
Y W
AK
UN
IV
ER
SI
TY
C
EN
TE
R
MI
N E3.1 SCALE: 1/8" = 1'-0"
S-WING FIRST FLOOR LIGHTING PLAN1
SYMBOL DESCRIPTION
KEYED CONSTRUCTION NOTES
1 CONNECT NEW LIGHT FIXTURE TO
EMERGENCY LIGHTING CIRCUIT.
2 INSTALL NEW LIGHT FIXTURES IN
EXISTING CEILING & CONNECT TO
SALVAGED CIRCUIT. PROVIDE CEILING
TILES & GRID AS NECESSARY TO
COMPLETE THE CEILING INSTALLATION.
3 PROVIDE RCMS PDT 9 AR G2
OCCUPANCY SENSOR WITH RPP20 D 24V
EFP G2 POWER PACK.
4 PROVIDE RPODLA DX MVOLT WH G2 LINE
POWERED WALL SWITCH.
NO
ST
AT
US
/ R
EV
IS
IO
NS
DA
TE
O W
NE
R
RE
VI
EW
-2 8-
O
W
NE
R
RE
VI
EW
-0
3-
IS
SU
ED
F
OR
B
ID
S
-0
8-
GENERAL NOTE:
REFER TO DETAIL ONE ON SHEET
E8.0 FOR TYPICAL CEILING & LIGHT
FIXTURE MODIFICATION DETAIL
Second Floor - Master Plan
OS
OS
OS
LV
D
LV
D
PP
PP
PP
PP
OS
OS
OS
OS
PP
LVD
Second Floor - Master Plan
MATCH LINE
THIS SHEET
MATCH LINE
THIS SHEET
F F F F
FFFF
F F F F
F
FF
FF
FF
F
F
F
F F F F
FF
FF
F F
FFFF
F F
FF
F F
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A A
A
A
A
A
A
A
A
A
B
B
B
B
BB
B B
B
B
B
B
B
B
ART ROOM LIGHTING NOTES:
PENDANT MOUNT FIXTURES OF TYPE F 9'-9" A.F.F.
SET FIXTURES TO MANUAL ON TO 100% LIGHT
OUTPUT. ON/OFF & DIMMING PROVIDED VIA LOCAL
SWITCHING. AUTO OFF AFTER 20 MINUTE VACANCY.
MATCH LINE
THIS SHEET
MATCH LINE
THIS SHEET
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
AA
A
A
A
A
A
A
A
A
A
A
A
A
A
B
B
B
B
B
B B
B
D
D
D
B
B B
B
B
B
W
IL
LI
AM
A . K
IB
BE
A
SS
O
C
IA
TE
S, IN
C
E
N G
IN
E
E R
S
A R
C H
IT
E
C
TS
S
U R
V E
Y O
R S
PR
IN
TE
D:
SHEET
PROJ #:
DRAWN BY:
DES'D BY:
CHCK'D BY:
/8/
2:
:37 P
M
25-0543-0153
B. KUSHION
B. KUSHION
E. MARTER
S- W
IN
G
SE
CO
ND
F
LO
OR
LI
GH
TI
NG
P
LA
N
DE
LT
A
CO
LL
EG
E
S- W
IN
G
CO
RR
ID
OR
LI
GH
TI
NG
E3.2
©2
7 - A
LL
R
IG
HT
S
RE
SE
RV
ED
. T
HI
S
DO
CU
ME
NT
A
ND
D
ES
IG
NS
P
OR
TR
AY
ED
W
IT
HI
N
AR
E
TH
E
PR
OP
ER
TY
O
F W
AK
, N
O
MO
DI
FI
CA
TI
ON
S
AN
D/
OR
T
RA
NS
FE
RS
O F
W
OR
K
AR
E
PE
RM
IT
TE
D
UN
LE
SS
G
RA
NT
ED
B
Y W
AK
UN
IV
ER
SI
TY
C
EN
TE
R
MI
N E3.2 SCALE: 1/8" = 1'-0"
S-WING SECOND FLOOR LIGHTING PLAN1
SYMBOL DESCRIPTION
KEYED CONSTRUCTION NOTES
1 CONNECT NEW LIGHT FIXTURE TO
EMERGENCY LIGHTING CIRCUIT.
2 INSTALL NEW LIGHT FIXTURES IN
EXISTING CEILING & CONNECT TO
SALVAGED CIRCUIT. PROVIDE CEILING
TILES & GRID AS NECESSARY TO
COMPLETE THE CEILING INSTALLATION.
3 PROVIDE RCMS PDT 9 AR G2
OCCUPANCY SENSOR WITH RPP20 D 24V
EFP G2 POWER PACK.
4 PROVIDE RPODLA DX MVOLT WH G2 LINE
POWERED WALL SWITCH.
NO
ST
AT
US
/ R
EV
IS
IO
NS
DA
TE
O W
NE
R
RE
VI
EW
-2 8-
O
W
NE
R
RE
VI
EW
-0
3-
IS
SU
ED
F
OR
B
ID
S
-0
8-
GENERAL NOTE:
REFER TO DETAIL ONE ON SHEET
E8.0 FOR TYPICAL CEILING & LIGHT
FIXTURE MODIFICATION DETAIL
EXISTING CEILING GRID TO REMAIN
REMOVE OR MODIFY EXISTING
CEILING GRID
NEW CEILING GRID AS REQUIRED
TO ACCOMMODATE NEW CEILING
TILES AND LIGHT FIXTURES
LEGEND:
W
IL
LI
AM
A . K
IB
BE
A
SS
O
C
IA
TE
S, IN
C
E
N G
IN
E
E R
S
A R
C H
IT
E
C
TS
S
U R
V E
Y O
R S
PR
IN
TE
D:
SHEET
PROJ #:
DRAWN BY:
DES'D BY:
CHCK'D BY:
/8/
2:
:37 P
M
25-0543-0153
B. KUSHION
B. KUSHION
E. MARTER
DE
TA
ILS
DE
LT
A
CO
LL
EG
E
S- W
IN
G
CO
RR
ID
OR
LI
GH
TI
NG
E8.0
©2
7 - A
LL
R
IG
HT
S
RE
SE
RV
ED
. T
HI
S
DO
CU
ME
NT
A
ND
D
ES
IG
NS
P
OR
TR
AY
ED
W
IT
HI
N
AR
E
TH
E
PR
OP
ER
TY
O
F W
AK
, N
O
MO
DI
FI
CA
TI
ON
S
AN
D/
OR
T
RA
NS
FE
RS
O F
W
OR
K
AR
E
PE
RM
IT
TE
D
UN
LE
SS
G
RA
NT
ED
B
Y W
AK
UN
IV
ER
SI
TY
C
EN
TE
R
MI
SCALE: 1/4" = 1'-0"E8.0
TYPICAL CEILING & LIGHT FIXTURE MODIFICATION DETAIL1
1 REMOVE EXISTING EGG CRATE GRILLS.
2 REMOVE EXISTING 2' CROSS TEE AS
REQUIRED TO ACCOMADATE NEW 1'x4'
LIGHT.
1 INSTALL NEW 2'x2" CEILING TILES. CUT
TO FIT IN EXISTING GRID. MATCH
EXISTING.
2 INSTALL NEW 2'x2" CEILING TILES. CUT
TO FIT IN EXISTING GRID. MATCH
EXISTING.
3 PROPOSED 1'x4' LED LIGHT FIXTURE. SEE
LIGHTING FIXTURE SCHEDULE.
SYMBOL DESCRIPTION
KEYED DEMOLITION NOTES
SYMBOL DESCRIPTION
KEYED CONSTRUCTION NOTES
NO
ST
AT
US
/ R
EV
IS
IO
NS
DA
TE
IS
SU
ED
F
OR
B
ID
S
-0
| CS - COVER SHEET |
| E0.0 - GENERAL NOTES |
| E0.1 - SPECIFICATIONS |
| E1.0 - S-WING LOWER LEVEL LIGHTING DEMOLITION PLAN |
| E1.1 - S-WING FIRST FLOOR LIGHTING DEMOLITION PLAN |
| E1.2 - S-WING SECOND FLOOR LIGHTING DEMOLITION PLAN |
| E3.0 - S-WING LOWER LEVEL LIGHTING PLAN |
| E3.1 - S-WING FIRST FLOOR LIGHTING PLAN |
| E3.2 - S-WING SECOND FLOOR LIGHTING PLAN |
| E8.0 - DETAILS |
File details come from the government source that posted it. Updated .