25-8418_NRO_Wells_118_and120_-_Drawing_M-3.pdf

PDF 340 KB Posted

Attached to
NRO Wells 118N and 120N Improvements
Solicitation number
25-8418
Issued by
Collier County, Florida

About this file

NRO Wells 118N and 120N Improvements - Drawing M-3

This is a mechanical drawing document prepared by CDM Smith for Collier County, Florida's NRO Wells 118N and 120N Improvements project (Bid No. 25-8418). The drawing depicts the proposed plan and section for Well 120N, showing detailed specifications for well infrastructure including a 24-inch steel surface casing, 16-inch fiberglass reinforced plastic casing, submersible pump installation at 135 feet below land surface, 12-inch and 6-inch stainless steel piping systems with associated valves, flow meters, and control mechanisms. The document specifies critical construction requirements including restrained joint pipe connections, Victaulic Style 489 stainless steel Type 316 couplings, dielectric insulating flange gasket kits, and fusion bonded epoxy coating on all ductile iron pipe and fittings for wet surfaces. The project timeline requires substantial completion within 365 calendar days from Notice to Proceed, with final completion due 30 days after Punch List delivery. A non-mandatory pre-bid meeting is scheduled for September 10, 2025, at 10:00 a.m., with sealed bids due October 8, 2025, at 3:00 p.m. local time.

The anticipated project budget is $2,900,000.00, with an additional $200,000 Owner's Allowance for unforeseen conditions. Liquidated damages are assessed at $1,201 per calendar day for failure to achieve substantial completion within the specified timeframe. Contractors must maintain $1,000,000 in commercial general liability coverage and comply with comprehensive Environmental, Health, and Safety requirements following OSHA, DOT, and EPA regulations. Bidders must be E-Verify registered, possess appropriate business tax receipts and professional licenses, and submit a 5% bid bond along with performance and payment bonds. The drawing was revised per Addendum No. 1 and was last updated on September 25, 2025, with final file modifications on September 18, 2025.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

M-3

PROPOSED NRO WELL 120N

PLAN AND SECTION

COLLIER COUNTY, FLORIDA

NRO WELLS 118N AND 120N

IMPROVEMENTS

FL COA No. EB-0000020

9160 FORUM CORPORATE PARKWAY., Suite 230 Fort Myers, FL 33905 Tel: (239) 938-9600

BID SET

SECTION 1

N

PLAN

AutoCAD SHX Text

M003WEPL.DWG

AutoCAD SHX Text

I. HOLOWELL

AutoCAD SHX Text

A. EDWARDS

AutoCAD SHX Text

M. STONEHOUSE

AutoCAD SHX Text

M. SUNYAK

AutoCAD SHX Text 09/25

AutoCAD SHX Text

AFE

AutoCAD SHX Text

IDH

AutoCAD SHX Text REVISED PER ADDENDUM No.1

AutoCAD SHX Text

I. HOLOWELL

AutoCAD SHX Text NOTES: 1. ALL PIPE JOINTS, VALVES, AND FITTINGS SHALL BE RESTRAINED. ALL PIPE JOINTS, VALVES, AND FITTINGS SHALL BE RESTRAINED. RESTRAINED JOINT CALCULATIONS WILL NOT BE ACCEPTED. 2. PROVIDE VICTAULIC STYLE 489 STAINLESS STEEL TYPE 316 PROVIDE VICTAULIC STYLE 489 STAINLESS STEEL TYPE 316 COUPLING. 3. INSTALL SUBMERSIBLE PUMP INTAKE AT A DETPH OF 135-FT INSTALL SUBMERSIBLE PUMP INTAKE AT A DETPH OF 135-FT BELOW LAND SURFACE. FINAL INSTALLED DEPTH TO BE CONFIRMED PENDING THE RESULTS OF WELL TESTING. 4. PROVIDE DIELECTRIC INSULATING FLANGE GASKET KITS AT PROVIDE DIELECTRIC INSULATING FLANGE GASKET KITS AT STAINLESS STEEL AND DUCTILE IRON CONNECTIONS. 5. ALL DUCTILE IRON PIPE AND FITTINGS REQUIRE FUSION BONDED ALL DUCTILE IRON PIPE AND FITTINGS REQUIRE FUSION BONDED EPOXY ON WET SURFACES. 6. FOR LUG OR WAFER STYLE BUTTERFLY VALVES, A SPOOL PIECE FOR LUG OR WAFER STYLE BUTTERFLY VALVES, A SPOOL PIECE MAY BE REQUIRED AT THE 90-DEGREE BEND TO ALLOW DISC TO OPEN FULLY.

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text G

AutoCAD SHX Text H

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

REV.

AutoCAD SHX Text

NO.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DRWN

AutoCAD SHX Text

CHKD

AutoCAD SHX Text

REMARKS

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

CROSS CHK'D BY:

AutoCAD SHX Text

APPROVED BY:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SHEET CHK'D BY:

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

PROJECT NO.

AutoCAD SHX Text

FILE NAME:

AutoCAD SHX Text CDM SMITH ALL RIGHTS RESERVED. REUSE OF DOCUMENTS: THESE DOCUMENTS AND DESIGNS PROVIDED BY PROFESSIONAL SERVICE, INCORPORATED HEREIN, ARE THE PROPERTY OF CDM SMITH AND ARE NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF CDM SMITH.

AutoCAD SHX Text

APRIL 2025

AutoCAD SHX Text 6295-296440

AutoCAD SHX Text

ISAAC DAVID HOLOWELL

AutoCAD SHX Text

PE NO. 83413

AutoCAD SHX Text

DATE:

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1/4%%34 = 1'- 0%%34

AutoCAD SHX Text

2" CAV W/ PIT

AutoCAD SHX Text

MD-1

AutoCAD SHX Text D

AutoCAD SHX Text 6"x90° BEND-SST6" BFV-SST

AutoCAD SHX Text

6" DROP PIPE-SST

AutoCAD SHX Text

6" THREADED COUPLING-SST

AutoCAD SHX Text 6" DROP PIPE ADAPTER-SST (CERTA-LOK MALExMALE THREAD NPT)

AutoCAD SHX Text

6" DROP PIPE COUPLING-PVC

AutoCAD SHX Text

6" DROP PIPE-PVC

AutoCAD SHX Text

16" FRP CASING

AutoCAD SHX Text

REFER TO DETAIL A/MD-1 FOR PUMP AND DROP PIPE DETAIL (SEE NOTE 3)

AutoCAD SHX Text

24" STEEL SURFACE CASING

AutoCAD SHX Text

6" CV-SST

AutoCAD SHX Text

6" FLOW METER

AutoCAD SHX Text

2" TAP W/ PIT

AutoCAD SHX Text

2" CAV

AutoCAD SHX Text

MD-1

AutoCAD SHX Text D

AutoCAD SHX Text 12"x6" TEE-SST

AutoCAD SHX Text

12" PIPE-DI

AutoCAD SHX Text

VICTAULIC COUPLING (SEE NOTE 2)

AutoCAD SHX Text

WELLHEAD SUPPORTING FLANGE

AutoCAD SHX Text

MD-1

AutoCAD SHX Text B

AutoCAD SHX Text

2" WELD-O-LET 1/2" BV

AutoCAD SHX Text

BLOWOFF 6" TEE 6" BFV-SST BLIND FLANGE-SST

AutoCAD SHX Text

CONCRETE PIPE SUPPORT (TYP)

AutoCAD SHX Text

MD-1

AutoCAD SHX Text C

AutoCAD SHX Text

MD-1

AutoCAD SHX Text E

AutoCAD SHX Text

16" WELLHEAD SUPPORTING FLANGE

AutoCAD SHX Text

MD-1

AutoCAD SHX Text B

AutoCAD SHX Text

2" CAV W/ PIT

AutoCAD SHX Text 6"x90° BEND-SST6" BFV-SST (SEE NOTE 6)

AutoCAD SHX Text

2" WELD-O-LET 1/2" BV

AutoCAD SHX Text

MD-1

AutoCAD SHX Text D

AutoCAD SHX Text

MD-1

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

BLOWOFF 6" TEE 6" BFV-SST BLIND FLANGE-SST

AutoCAD SHX Text 12"x6" TEE-SST W/ 2" CAV

AutoCAD SHX Text

6" FLOW METER

AutoCAD SHX Text

VICTAULIC COUPLING (SEE NOTE 2)

AutoCAD SHX Text

6" CV-SST

AutoCAD SHX Text

MD-1

AutoCAD SHX Text D

AutoCAD SHX Text

CONCRETE PIPE SUPPORT (TYP)

AutoCAD SHX Text

MD-1

AutoCAD SHX Text C

AutoCAD SHX Text

2" TAP W/ PIT

AutoCAD SHX Text

SEE SHEET C-2 FOR CONTINUATION

AutoCAD SHX Text

12" RW-PVC

AutoCAD SHX Text

SEE SHEET C-1 FOR CONTINUATION

AutoCAD SHX Text 12"x90° BEND-SST (FLG)

AutoCAD SHX Text

12" GATE VALVE

AutoCAD SHX Text

6" BFV-SST

AutoCAD SHX Text

12" GATE VALVE (MJ-RJ)

AutoCAD SHX Text

6" BFV-SST

AutoCAD SHX Text

T/SLAB EL (REFER TO CIVIL SHEETS)

AutoCAD SHX Text 3'-0"

AutoCAD SHX Text

ELECTRICAL PANELS (SEE ELECTRICAL SHEETS)

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

2" CAV

AutoCAD SHX Text

316SS

AutoCAD SHX Text

DIP (SEE NOTES 4 AND 5)

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Last saved by: EDWARDSAF Time: 9/18/2025 12:41:06 PM

AutoCAD SHX Text XREFs: [CDMS_2234, MWP000WE, MWS000WE, MES000WE, EWP000WE19, SWP000NW, 12390 - ASB - FO_119 record, CWP000ST, EWP002WE] Images: []

AutoCAD SHX Text pw:\\cdmsmith-az02-pw.bentley.com:pw_pl1\6295\296440\04 Design Services NM_Bid\05 Process Mechanical\10 BIM_CADD\M003WEPL.dwg

2025-09-30T12:01:53-0400
Isaac D Holowell
FL PE# 83413

File details come from the government source that posted it. Updated .