25-8418_Bid_Schedule.xlsx
XLSX spreadsheet 16 KB Posted
- Attached to
- NRO Wells 118N and 120N Improvements
- Solicitation number
- 25-8418
- Issued by
- Collier County, Florida
About this file
This document is a Bid Schedule for Collier County, Florida, for the NRO Wells 118N and 120N Improvements project (Bid No. 25-8418). The solicitation involves improvements to two wells, including installation of pumps, motors, piping, electrical and instrumentation/controls, and well conditioning. The bid is scheduled to be advertised on August 22, 2025, with sealed bids due by October 8, 2025 at 3:00 p.m. local time. A non-mandatory pre-bid meeting will be held on September 10, 2025 at 10:00 a.m. at the Collier County Procurement Services Conference Room. Bidders must register on the county's procurement portal to obtain complete project documents.
The bid schedule details specific line items for well improvements, including mobilization, structural work, electrical upgrades, instrumentation, wellhead modifications, and comprehensive well conditioning services. The project includes pre-treatment surveys, pump testing, chemical treatment, development work, and water sampling across Wells 118N, 120N, and 119N. The total anticipated project budget is $2,900,000.00, with an additional $200,000 Owner's Allowance allocated for unforeseen conditions or owner-directed work. The bid schedule currently shows placeholder pricing (all line items at $0), indicating that actual pricing will be submitted by bidders during the procurement process.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Bid Schedule
| 4/8/25 |
| Bid Schedule |
| NRO Wells 118N and 120N Improvements | |||||
| Item No. | Description | Quantity | Unit | Unit Price | Total |
| General | |||||
| 1 | Mobilization-Demobilization (not to exceed 10% of the Total Bid Amount) | 1 | LS | $ - 0 | |
| Subtotal | $ - 0 | ||||
| Well 118N Improvements | |||||
| 2 | Misc. Structural | 1 | LS | $ - 0 | |
| 3 | Misc. Electrical | 1 | LS | $ - 0 | |
| 4 | Instrumentation & Controls | 1 | LS | $ - 0 | |
| 5 | Wellhead, Pump and Motor | 1 | LS | $ - 0 | |
| 6 | Misc. Piping, Valves and Fittings | 1 | LS | $ - 0 | |
| Subtotal | $ - 0 | ||||
| Well 120N Improvements | |||||
| 7 | Misc. Structural | 1 | LS | $ - 0 | |
| 8 | Misc. Electrical | 1 | LS | $ - 0 | |
| 9 | Instrumentation & Controls | 1 | LS | $ - 0 | |
| 10 | Wellhead, Pump and Motor | 1 | LS | $ - 0 | |
| 11 | Misc. Piping, Valves and Fittings | 1 | LS | $ - 0 | |
| Subtotal | $ - 0 | ||||
| Well Conditioning | |||||
| 12 | Well Conditioning (reference WSA, Inc. Specification Section) | ||||
| 12-1 | Perform pre-treatment downhole video survey. | 2 | EA | $ - 0 | |
| 12-2 | Install temporary test pump and perform pre-treatment step-drawdown test. | 2 | EA | $ - 0 | |
| 12-3 | Install required temporary wellhead, isolation packer, and tubing. Treat each well using 6,000 gallons of HCL as specified. | 2 | EA | $ - 0 | |
| 12-4 | Conduct airlift surge development for 16 hours per well. | 32 | Hours | $ - 0 | |
| 12-5 | Install temporary test pump and perform post-treatment high-rate pump development for 16 hours per well. Perform sand content, turbidity and silt density index testing during pump development. | 32 | Hours | $ - 0 | |
| 12-6 | Conduct post-treatment step-drawdown test. | 2 | EA | $ - 0 | |
| 12-7 | Collect water samples and provide analysis results for primary and secondary drinking water standards. | 2 | EA | $ - 0 | |
| 12-8 | Disinfect well as specified. | 2 | EA | $ - 0 | |
| 12-9 | Clean and restore site | 1 | LS | $ - 0 | |
| Subtotal | $ - 0 | ||||
| Well 119N Electrical Improvements | |||||
| 13 | Verification of Existing Wiring | 1 | LS | $ - 0 | |
| 14 | Wiring Installation | 1 | LS | $ - 0 | |
| 15 | Conduit Installation | 150 | LF | $ - 0 | |
| Subtotal | $ - 0 |
| TOTAL BID AMOUNT | $ - 0 |
| * Staff has allocated $200,000 in Owner's Allowance - for Owners Use as Directed. This Allowance will be used only at the Owner's direction to accomplish work due to unforeseen conditions and/or as directed by the Owner. Inclusion of the Allowance as part of the Contract Price is not a guarantee that the Contractor will be paid any portion or the full amount of the Allowance. Expenditures of Owners Allowance will be made through Change Order with proper documentation of Time and Materials supporting the change. |
NRO Wells 118N and 120N Improvements Engineer's Opinion of Probable Cost April 2025
File details come from the government source that posted it. Updated .