25-8371_-_Exhibit_L-2_-_Lighting_Design_Analysis_Rerport_SS.pdf

PDF 3 MB Posted

Attached to
First Street Corridor Phase I
Solicitation number
25-8371
Issued by
Collier County, Florida

About this file

This document is a Lighting Design Analysis Report prepared by Kisinger Campo & Associates (KCA) for Collier County, Florida, focusing on the South 1st Street (Immokalee Road - C.R. 846 E) lighting improvement project. The project aims to enhance pedestrian and motorist safety by upgrading street lighting from School Road / Seminole Crossing Trail to Eustis Avenue. The design utilizes GE Evolve ERL2 150W LED luminaires, with two pole types: conventional light poles mounted at 40' with an 8' arm and retrofit luminaires on utility poles mounted at 34' with a 12' arm. The lighting design follows the Florida Department of Transportation's corridor lighting criteria, with a focus on improving illuminance uniformity and providing adequate vertical illumination for Rectangular Rapid Flashing Beacon (RRFB) crosswalks.

The report includes detailed photometric analysis using AGi32 software, demonstrating compliance with FDOT lighting standards such as a horizontal average illumination of 1.5 footcandles, an average-to-minimum ratio of 4:1 or less, and a maximum-to-minimum ratio of 10:1 or less. A new 240V load center is proposed with a spare circuit for future lighting phases. The voltage drop calculations show a minimal voltage drop of 0.33%, well within the maximum allowable 0.80%. The ultimate project condition will extend beyond this phase, ending at Main Street (CR 29), with plans to implement safer, more focused pedestrian crossings by reducing RRFB crossing locations and removing non-RRFB crosswalks.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SOUTH 1ST STREET: LIGHTING DESIGN MEMO

January 2025 1

COLLIER COUNTY

LIGHTING DESIGN ANALYSIS REPORT

S&S Submittal – January 2025

SOUTH 1ST STREET (IMMOKALEE ROAD - C.R. 846 E)

FROM SCHOOL RD. / SEMINOLE CROSSING TRAIL TO EUSTIS AVE

IMMOKALEE, FLORIDA

PROJECT NO.: 33831-01

This report has been digitally signed and sealed by

On the date adjacent to the seal.

Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.

Kisinger Campo & Associates 201 N. Franklin Street, Suite 900

Tampa, FL 33602 SCOTT R. SAMUELS, P.E. No. 88738

January 2025 2

Table of Contents

1. Introduction

1.1. Project Description

2. Lighting Analysis

2.1. Lighting Criteria

2.2. Photometric Analysis

2.3. Electrical Power Service

Appendix A: Photometric Results

Appendix B: Manufacturer’s Specifications

Appendix C: Voltage Drop Calculations

January 2025 3

1. Introduction

This Lighting Design Analysis Report (LDAR) has been prepared by Kisinger Campo & Associates

(KCA) as part of Project No.: 33831-01 along South 1st Street (Immokalee Road - C.R. 846 E) in

Immokalee, FL. The purpose of this memorandum is to report the results of the lighting analysis

(photometric calculations) conducted for Project No.: 33831-01 using Light Emitting Diode (LED) luminaires. The analysis was based on FDOT’s roadway lighting criteria for Corridor Lighting.

1.1. Project Description

The purpose of this project is to improve pedestrian and motorist safety on South 1st Street in

Immokalee, FL through lighting improvements. This phase of the project includes lighting improvements on South 1st Street (Immokalee Road - C.R. 846 E) from School Rd. / Seminole

Crossing Trail to Eustis Ave. The ultimate condition will include improvements beyond this phase, ending at Main St (CR 29). The ultimate condition will have safer and more focused pedestrian crossings, using Rectangular Rapid Flashing Beacons (RRFBs) at fewer crossing locations and removing non-RRFB crosswalks.

The existing LED street lighting is spaced outside of the acceptable levels of corridor illuminance uniformity and will not provide adequate vertical illumination for the RRFB crosswalks. By upgrading the existing lighting with pedestrian safety and corridor uniformity in mind, the ultimate condition will greatly improve pedestrian visibility and multimodal safety. Utilizing existing utility pole lighting with retrofit LEDs and proposed conventional light poles will allow for standard uniformity levels to be met while managing high installation costs.

2. Lighting Analysis

2.1. Lighting Criteria

The lighting for this project will be designed in accordance with the Florida Department of

Transportation’s Design Manual (FDM) Chapter 231 for Corridor Lighting. The criteria is summarized in Table 2.1.

January 2025 4

Table 2.1: FDOT Lighting Criteria

Illumination Level

Corridor Lighting

Horizontal Average Illumination (HFC) 1.5

Vertical Average Illumination (VFC) N/A

Avg. / Min 4:1 or less

Max / Min 10:1 or less

Veiling Luminance Ratio 0.3:1 or less

2.2. Photometric Analysis

The design application used in performing the photometric analysis was AGi32. The design luminaire selected is the GE Evolve ERL2 150W luminaire, which is an approved luminaire by Collier County.

There are two pole types for the proposed lighting. Conventional light poles will be mounted at 40’ and use an 8’ arm. Retrofit luminaires mounted on utility poles will be mounted at 34’ and use a 12’ arm. Appendix A summarizes the results of the photometric analysis, and Appendix B displays the manufacturer’s specifications for the GE Evolve ERL2.

2.3. Electrical Power Service

A new 240V load center is proposed on the project with spare circuit for the future lighting proposed in the next phase. The loads on each spare circuit will be determined in the next phase. The service point details and voltage drop calculations for the single active circuit are shown in Appendix C.

January 2025 5

Appendix A: Photometric Results

201 N. Franklin Street, Suite 400 Tampa, FL 33602 SCOTT R. SAMUELS, P.E. No. 88738

LIGHTING DESIGN ANALYSIS REPORT

SOUTH 1ST STREET (IMMOKALEE ROAD - C.R. 846 E)

PROJECT NO.: 33831-01

PAGE

PHOTOMETRIC RESULTS

Kisinger Campo & Associates 201 N. Franklin Street, Suite 400 Tampa, FL 33602 SCOTT R. SAMUELS, P.E. No. 88738

LIGHTING DESIGN ANALYSIS REPORT

SOUTH 1ST STREET (IMMOKALEE ROAD - C.R. 846 E)

PROJECT NO.: 33831-01

PAGE

Luminaire Schedule

Calculation Summary Label CalcType Units Avg Max Min

Symbol Label Description Luminaire Lumens

Luminaire Watts

Total

Avg/Min Max/Min LV Ratio

Watts

NB Illuminance

Isoline Legend Illuminance (Fc)

Fc 1.55 3.2 0.4

Color

3.88 8.00 N.A.

Value

SB Illuminance Fc 1.60 4.2 0.5 3.20 8.40 N.A.

NB_1_Veil_Lum Veiling Luminance Cd/Sq.m 0.03 0.1 0.0 N.A. N.A. 0.08

0.5

NB_10_Veil_Lum Veiling Luminance Cd/Sq.m 0.25 0.3 0.2 1.25 1.50 0.12 NB_2_Veil_Lum

Veiling Luminance Cd/Sq.m 0.23 0.3 0.1 2.30 3.00 0.23 NB_3_Veil_Lum Veiling Luminance Cd/Sq.m 0.25 0.3 0.2 1.25 1.50 0.27 NB_4_Veil_Lum Veiling Luminance

1.5

Cd/Sq.m 0.16 0.3 0.1 1.60 3.00 0.23 NB_5_Veil_Lum Veiling Luminance Cd/Sq.m 0.10 0.2 0.1 1.00 2.00 0.10

ERL2_19C330______1 Utility Pole Mounted Lights

(MH= 34')

18200 149 745

ERL2_19C330_____ Conventional Light Pole (MH=40') 18200 149 4172

NB_6_Veil_Lum Veiling Luminance Cd/Sq.m

Veiling Luminance Cd/Sq.m 0.18 0.2 0.1 1.80 2.00 0.11 SB_6_Veil_Lum Veiling Luminance Cd/Sq.m 0.22 0.3 0.1 2.20 3.00 0.22 SB_7_Veil_Lum Veiling Luminance Cd/Sq.m 0.17 0.3 0.1 1.70 3.00 0.20 SB_8_Veil_Lum Veiling Luminance Cd/Sq.m 0.20 0.3 0.1 2.00 3.00 0.26 SB_9_Veil_Lum Veiling Luminance Cd/Sq.m 0.17 0.3 0.1 1.70 3.00 0.21

0.26 0.3 0.1 2.60 3.00 0.18 NB_7_Veil_Lum Veiling Luminance Cd/Sq.m 0.22 0.3 0.1 2.20 3.00 0.25 NB_8_Veil_Lum Veiling Luminance Cd/Sq.m 0.20 0.3 0.1 2.00 3.00 0.23 NB_9_Veil_Lum Veiling Luminance Cd/Sq.m 0.18 0.3 0.1 1.80 3.00 0.16 SB_1_Veil_Lum Veiling Luminance Cd/Sq.m 0.00 0.0 0.0 N.A. N.A. 0.00 SB_10_Veil_Lum Veiling Luminance Cd/Sq.m 0.22 0.3 0.1 2.20 3.00 0.21 SB_2_Veil_Lum Veiling Luminance Cd/Sq.m 0.15 0.3 0.0 N.A. N.A. 0.22 SB_3_Veil_Lum Veiling Luminance Cd/Sq.m 0.17 0.2 0.1 1.70 2.00 0.15 SB_4_Veil_Lum Veiling Luminance Cd/Sq.m 0.18 0.3 0.1 1.80 3.00 0.20 SB_5_Veil_Lum

Tampa, FL 33602 SCOTT R. SAMUELS, P.E. No. 88738

LIGHTING DESIGN ANALYSIS REPORT

SOUTH 1ST STREET (IMMOKALEE ROAD - C.R. 846 E)

PROJECT NO.: 33831-01

PAGE

PHOTOMETRIC PLAN

23 24 25 26 27

.2

C B

C B 1

.3

.4

.1

GRASS

GRASS

GRASSGRASS

DITCH

DITCH

DITCH

DITCH

DITCH

D R

IV

E

A S

H P

GRASSGRASSGRASS

GRASS

GRASS

Tampa, FL 33602 SCOTT R. SAMUELS, P.E. No. 88738

LIGHTING DESIGN ANALYSIS REPORT

SOUTH 1ST STREET (IMMOKALEE ROAD - C.R. 846 E)

PROJECT NO.: 33831-01

PAGE

PHOTOMETRIC PLAN

27 28 29 30 31

.2

C B

C B

C B

C B

D

D

GRASS

GRASSGRASS

D R

IV

E

A S

H P

D R

IV

E

A S

H P

GRASS

GRASS

GRASS

Tampa, FL 33602 SCOTT R. SAMUELS, P.E. No. 88738

LIGHTING DESIGN ANALYSIS REPORT

SOUTH 1ST STREET (IMMOKALEE ROAD - C.R. 846 E)

PROJECT NO.: 33831-01

PAGE

PHOTOMETRIC PLAN

32 33 34 35 36 P I

S T A .3

B

BB

B

C B

.7

GRASS

GRASS

GRASS

GRASS

D R

IV

E

A S

H P

GRASS

GRASSGRASS

January 2025 10

Appendix B: Manufacturer’s Specifications

ERLC-ERL1-ERL2

LED Roadway Lighting

Arize ERL2 Cobra Head LED Roadway Lighting

PROJECT NAME

DATE TYPE

CATALOG NUMBER

CUSTOMER NAME

The Evolve® LED Roadway ERL2 Luminaire is optimized utilizing advanced LED reflective optical system for local, collector and major roadways. The modern design incorporates the heat sink directly into the unit for heat transfer to prolong LED life.

Construction

Housing:

Aluminum die cast enclosure. Casting Integral heat sink for maximum heat transfer

Lens: Impact resistant tempered glass

Paint:

Corrosion resistant polyester powder painted, minimum 2.0 mil thickness (RAL & custom colors available) Standard = Black, Dark Bronze Gray, White Optional = Coastal Finish

Weight: 24.0 lbs (10.9 kgs)

Lumens: 16,000 - 32,000

Distribution: Type II Narrow, Type II Wide, Type III, Type IV and Type II Enhanced Back light

Efficacy: 112-140 LPW

CCT: 2700K, 3000K, 4000K, 5000K

CRI (Min): 70 CRI

Optical System

Controls

Dimming: Standard-0-10V Optional-DALI (Option U)

Sensors: Photo Electric Sensors (PE) available LightGrid Compatible

Warranty

5 Year (Standard) 10 Year (Optional)

Electrical

Input Voltage: 120-277V or 347-480V

Input Frequency: 50/60Hz

Power Factor: ≥ 90% at rated watts

Total Harmonic Distortion: ≤ 20% at rated watts

Surge Protection*

STANDARD OPTIONAL

10kV/5kA Secondary 10kV/5kA (R Option) or Secondary 20kV/10kA (T Option)

*Per ANSI C136.2-2018

Operating Temp: -40°C to 50°C *

Vibration: 3G per ANSI C136.31-2018

LM-79: Testing in accordance with IES Standards

EMI: Title 47 CFR Part 15 Class A

RoHS: Complies with the material restrictions of RoHS

Ratings

*ERL2 (32K Lumen 347-480V SKU) operates at -40°C to 45°C

Optical Enclosures

Lumen Maintenance

Projected Lxx per IES TM-21-11 at 25°C

LUMEN

CODES DISTRIBUTIONS

LXX(10K) @ HOURS

25,000

HR

50,000

HR

60,000

HR

16 A5, B5, C5, D5, E5 L99 L99 L99

18 A5, B5, C5, D5, E5 L99 L98 L98

19 A5, B5, C5, D5, E5 L99 L98 L97

21 A5, B5, C5, D5, E5 L94 L87 L85

23 A5, B5, C5, D5, E5 L97 L96 L95

25 A5, B5, C5, D5, E5 L96 L95 L95

27 A5, B5, C5, D5, E5 L96 L94 L94

28 A5, B5, C5, D5, E5 L96 L94 L93

30, 31 A5, B5, C5, D5, E5 L95 L93 L92

32 A5, B5, C5, D5, E5 L94 L91 L90

Note: Projected Lxx based on LM80 (≥ 10,000 hour testing). Accepted Industry tolerances apply to initial luminous flux and lumen maintenance measurements.

Not all product variations listed on this page are DLC qualified.

Visit www.designlights.org/search to confirm qualifications.

UL1598

LED.com © 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions.

(Rev 06/28/23)

OLP3187_R06

http://www.designlights.org/search

LED Roadway Lighting

PROJECT NAME

DATE TYPE

CATALOG NUMBER

CUSTOMER NAME

E R L 2_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ PROD. ID VOLTAGE LUMENS (LM) DISTRIBUTION3 CCT CONTROLS PER ANSI C136.41 COLOR OPTIONS

E = Evolve 0 = 120-277V 1 16 = 16,000 lm A5 = Type II Narrow 27 = 2700K2 A = 7-Pin Receptacle GRAY = Gray A = 4 Bolt Slipfitter4

R = Roadway H = 347-480V1 18 = 18,000 lm B5 = Type II Wide 30 = 3000K2 D = 7-Pin Receptacle with Shorting Cap

BLCK = Black B = Tether

L = Local 1 = 120V 19 = 19,000 lm C5 = Type III 40 = 4000K E = 7-Pin Receptacle with non-Dimming Long Life PE5

DKBZ = Dark Bronze F = Fusing

2 = Double Module

2 = 208V 21 = 21,000 lm D5 = Type IV10 50 = 5000K Note: 0-10V control standard unless DALI Option "U" requested

WHTE = White G = Internal Bubble Level

3 = 240V 23 = 23,000 lm E5 = Type II Enhanced Back Light

I = Optional IP66 Optical Enclosure

4 = 277V 25 = 25,000 lm L = Tool-Less Entry

D = 347V 27 = 27,000 lm R = Secondary 10kV/5kA SPD

5 = 480V 28 = 28,000 lm T = Secondary 20kV/10kA SPD1

30 = 30,000 lm U = DALI Programmable6 ,7

31 = 31,000 lm V1 = Field Adjustable Module9

32 = 32,000 lm Y = Coastal Finish8

XXX = Special Options

1 Not Available with Fusing 2 Select 2700K or 3000K CCT for IDA approved units 3 Nominal IES Type classing subject to typical variation, individual units may differ 4 Lead time varies, contact Factory 5 Per ANSI C136.10-2017 6 Compatible with LightGrid 7 Not available in 347V, 480V or 347-480V 8 Recommended for installations within 750 feet from coast. Lead time varies, check with factory.

9 Not available with DALI "U" option 10 Forward throw distribution. Classifies as Type III for lumen codes 23-32. Review IES curve for application.

Suggested HID Replacement

Approximately 21,500 -32,000 lumens to replace 400W HPS Cobra-head

Note: actual replacement lumens may vary based upon mounting height, pole spacing, design criteria, etc.

Ordering Information

LED.com © 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions.

(Rev 06/28/23)

LED Roadway Lighting

PROJECT NAME

DATE TYPE

CATALOG NUMBER

CUSTOMER NAME

LUMEN

OUTPUT

DIST.

TYPICAL INITIAL LUMENS WATTAGE BUG RATINGS

5000K/ 4000K

3000K 2700K 120V 277V

347V 480V

5000K/4000K 3000K 2700K

A5

16000 15300 14200 114

B3-U0-G3 B3-U0-G3 B3-U0-G3

B5 B3-U0-G3 B3-U0-G3 B2-U0-G2

C5 B2-U0-G3 B2-U0-G3 B2-U0-G3

D5 B2-U0-G3 B2-U0-G3 B2-U0-G2

E5 B3-U0-G3 B3-U0-G3 B3-U0-G3

A5

18000 17200 16000 130

B3-U0-G3 B3-U0-G3 B3-U0-G3

B5 B3-U0-G3 B3-U0-G3 B3-U0-G3

C5 B3-U0-G3 B2-U0-G3 B2-U0-G3

D5 B2-U0-G3 B2-U0-G3 B2-U0-G3

E5 B3-U0-G3 B3-U0-G3 B3-U0-G3

A5

19000 18200 16900 140

B3-U0-G3 B3-U0-G3 B3-U0-G3

B5 B3-U0-G3 B3-U0-G3 B3-U0-G3

C5 B3-U0-G3 B3-U0-G3 B2-U0-G3

D5 B2-U0-G3 B2-U0-G3 B2-U0-G3

E5 B3-U0-G3 B3-U0-G3 B3-U0-G3

A5

21000 20100 18600 160

B3-U0-G3 B3-U0-G3 B3-U0-G3

B5 B3-U0-G3 B3-U0-G3 B3-U0-G3

C5 B3-U0-G3 B3-U0-G3 B3-U0-G3

D5 B2-U0-G3 B2-U0-G3 B2-U0-G3

E5 B3-U0-G3 B3-U0-G3 B3-U0-G3

A5

23000 22000 21300 177

B3-U0-G3 B3-U0-G3 B3-U0-G3

B5 B3-U0-G3 B3-U0-G3 B3-U0-G3

C5 B3-U0-G4 B3-U0-G4 B3-U0-G3

D5 B2-U0-G3 B2-U0-G3 B2-U0-G3

E5 B3-U0-G3 B3-U0-G3 B3-U0-G3

A5

25000 24000 23200 191

B3-U0-G3 B3-U0-G3 B3-U0-G3

B5 B3-U0-G3 B3-U0-G3 B3-U0-G3

C5 B3-U0-G4 B3-U0-G4 B3-U0-G4

D5 B2-U0-G4 B2-U0-G4 B2-U0-G3

E5 B4-U0-G4 B4-U0-G4 B4-U0-G4

For additional information on ERL2 IES files, please click one of the following links:

LED.com © 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions.

(Rev 06/28/23)

OLP3187_R06

https://instabase.lightinganalysts.com/IITC/?uid=902-PF5BFFYPSR7BDEHGXV26PTEG&selectedIDBs=1663%2C1665%2C1667%2C1669&textSrch=ERL2%20EVOLVE%20x5%20distribution&expand=1&setView=0&sam=1#tabs-Search https://instabase.lightinganalysts.com/IITC/?uid=902-PF5BFFYPSR7BDEHGXV26PTEG&selectedIDBs=1663,1665,1667,1669&textSrch=ERLC%20EVOLVE%20x4%20Distribution%20with%20shielding&expand=1&setView=0&sam=1#tabs-Search https://instabase.lightinganalysts.com/IITC/?uid=902-PF5BFFYPSR7BDEHGXV26PTEG&selectedIDBs=1663%2C1665%2C1667%2C1669&textSrch=ERL2%20EVOLVE%20x5%20with%20shielding&expand=1&setView=0&sam=1#tabs-Search https://instabase.lightinganalysts.com/IITC/?uid=902-PF5BFFYPSR7BDEHGXV26PTEG&selectedIDBs=1663,1665,1667,1669&textSrch=ERLC%20EVOLVE%20x4%20Distribution&expand=1&setView=0&sam=1#tabs-Search

LED Roadway Lighting

PROJECT NAME

DATE TYPE

CATALOG NUMBER

CUSTOMER NAME

LUMEN

OUTPUT

DIST.

TYPICAL INITIAL LUMENS WATTAGE BUG RATINGS

5000K/ 4000K

3000K 2700K 120V 277V

347V 480V

5000K/4000K 3000K 2700K

A5

27000 25900 25100 212

B4-U0-G4 B4-U0-G4 B3-U0-G3

B5 B3-U0-G3 B3-U0-G3 B3-U0-G3

C5 B3-U0-G4 B3-U0-G4 B3-U0-G4

D5 B2-U0-G4 B2-U0-G4 B2-U0-G4

E5 B4-U0-G4 B4-U0-G4 B4-U0-G4

A5

28000 26800 26000 223

B4-U0-G4 B4-U0-G4 B4-U0-G4

B5 B3-U0-G4 B3-U0-G3 B3-U0-G3

C5 B3-U0-G4 B3-U0-G4 B3-U0-G4

D5 B3-U0-G4 B3-U0-G4 B2-U0-G4

E5 B4-U0-G4 B4-U0-G4 B4-U0-G4

A5

30000 28800 27900 242

B4-U0-G4 B4-U0-G4 B4-U0-G4

B5 B3-U0-G4 B3-U0-G4 B3-U0-G4

C5 B3-U0-G4 B3-U0-G4 B3-U0-G4

D5 B3-U0-G4 B3-U0-G4 B3-U0-G4

E5 B4-U0-G4 B4-U0-G4 B4-U0-G4

A5

31000 29700 28800 252

B4-U0-G4 B4-U0-G4 B4-U0-G4

B5 B3-U0-G4 B3-U0-G4 B3-U0-G4

C5 B3-U0-G4 B3-U0-G4 B3-U0-G4

D5 B3-U0-G4 B3-U0-G4 B3-U0-G4

E5 B4-U0-G4 B4-U0-G4 B4-U0-G4

A5

32000 30700 29700 265

B4-U0-G4 B4-U0-G4 B4-U0-G4

B5 B3-U0-G4 B3-U0-G4 B3-U0-G4

C5 B3-U0-G4 B3-U0-G4 B3-U0-G4

D5 B3-U0-G4 B3-U0-G4 B3-U0-G4

E5 B4-U0-G4 B4-U0-G4 B4-U0-G4

For additional information on ERL2 IES files, please click one of the following links:

LED.com © 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions.

(Rev 06/28/23)

OLP3187_R06

https://instabase.lightinganalysts.com/IITC/?uid=902-PF5BFFYPSR7BDEHGXV26PTEG&selectedIDBs=1663%2C1665%2C1667%2C1669&textSrch=ERL2%20EVOLVE%20x5%20distribution&expand=1&setView=0&sam=1#tabs-Search https://instabase.lightinganalysts.com/IITC/?uid=902-PF5BFFYPSR7BDEHGXV26PTEG&selectedIDBs=1663,1665,1667,1669&textSrch=ERLC%20EVOLVE%20x4%20Distribution%20with%20shielding&expand=1&setView=0&sam=1#tabs-Search https://instabase.lightinganalysts.com/IITC/?uid=902-PF5BFFYPSR7BDEHGXV26PTEG&selectedIDBs=1663%2C1665%2C1667%2C1669&textSrch=ERL2%20EVOLVE%20x5%20with%20shielding&expand=1&setView=0&sam=1#tabs-Search https://instabase.lightinganalysts.com/IITC/?uid=902-PF5BFFYPSR7BDEHGXV26PTEG&selectedIDBs=1663,1665,1667,1669&textSrch=ERLC%20EVOLVE%20x4%20Distribution&expand=1&setView=0&sam=1#tabs-Search

LED Roadway Lighting

PROJECT NAME

DATE TYPE

CATALOG NUMBER

CUSTOMER NAME

ERL2

Type II Narrow

32,000 Lumens 5000K

ERL2_32A550_____.IES

ERL2

Type II Wide

32,000 Lumens 5000K

ERL2_32B550_____.IES

ERL2

Type III

32,000 Lumens 5000K

ERL2_32C550_____.IES

ERL2

Type III (FWT)

32,000 Lumens 5000K

ERL2_32D550_____.IES

Forward Throw

ERL2

Type II Medium

32,000 Lumens 5000K

ERL2_32E550_____.IES

— Vertical plane at max Cd horiz. angle 80°

— Horizontal cone at max Cd vert. angle 68°

— Vertical plane at max Cd horiz. angle 75°

— Horizontal cone at max Cd vert. angle 70°

— Vertical plane at max Cd horiz. angle 70°

— Horizontal cone at max Cd vert. angle 70°

— Vertical plane at max Cd horiz. angle 50°

— Horizontal cone at max Cd vert. angle 59°

— Vertical plane at max Cd horiz. angle 75°

— Horizontal cone at max Cd vert. angle 67°

• Mounting Height at 30’

• Initial Footcandle at Grade

• Mounting Height at 30’

• Initial Footcandle at Grade

• Mounting Height at 30’

• Initial Footcandle at Grade

• Mounting Height at 30’

• Initial Footcandle at Grade

• Mounting Height at 30’

• Initial Footcandle at Grade

.1 .2

.5

21856

10928

16392

.1 .2

.5

26351

13175

19763

.1

.2

29340

14670

22005

.5

ISO illuminate diagrams and polar plots are representative of the SKUs illustrated.

Refer to IES files for SKU specific information.

19975

14981

.1 .2

.5

23492

19869

13246

.1 .2 .5

LED.com © 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions.

LED Roadway Lighting

PROJECT NAME

DATE TYPE

CATALOG NUMBER

CUSTOMER NAME

Effective Projected Area

• 0.57 sq ft max (0.053 sq m)

Weight

• 24.0 lbs (10.9 kgs) Network Lighting Controls

Current's LightGridTM Outdoor Lighting Control System is designed for Street and Roadway Applications.

It enables remote monitoring, control, and asset management of a single fixture or a group of fixtures through a web enabled Central Management System.

Accessories

SAP NUMBER PART

NUMBER DESCRIPTION

93029237G PED-MV-LED-7

ANSI C136.41 Dimming PE, 120- 277V

93029238G PED-347-LED-7 ANSI C136.41 Dimming PE, 347V

93029239G

PED-480-

LED-7

ANSI C136.41 Dimming PE, 480V

28299 PEC0TL Long Life PE 120-277V

93147530 PECHTL Long Life PE 347-480V

73251 SCCL-PECTL Shorting Cap

Mounting

• Adjustable for 1.25 to 2 in. nominal mounting pipe(1.660 to

2.375 inch OD)

• Integral diecast mounting pipe stop

• Slipfitter with +/- 5 degrees of leveling adjustment

BACK VIEW SIDE VIEW FRONT VIEW

LED.com © 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions.

(Rev 06/28/23) https://www.gecurrent.com/controls-sensors/lightgrid

Cobra Head Shield Guide

PROJECT NAME

DATE TYPE

CATALOG NUMBER

CUSTOMER NAME

ERLC Shields

Product Code:

93110037G Description: ELSHS-ERLC-BLCK

Product Code:

93110038G Description: ELSHS-ERLC-GRAY

ERL1 Shields

Product Code:

93024487G Description: ELSHS-ERL1-BLCK

Product Code:

93046386G Description: ELSHS-ERL1-GRAY

Product Code:

93068998 Description: ELSHS-ERL1-DKBZ

ERL2 Shields

Product Code:

93070722 Description: ELSHS-ERL2-BLCK

Product Code:

93085564G Description: ELSHS-ERL2-GRAY

Product Code:

93096747G Description: ELSHS-ERL2-DKBZ

ERLC Shields

Product Code:

93132372 Description: ELSFS-ERLC-BLCK-10

Product Code:

93132373 Description: ELSFS-ERLC-BLCK-15

Product Code:

93134760 Description: ELSFS-ERLC-BLCK-20

ERL1 Shields

Product Code:

93092595 Description: ELSFS-ERL1-BLCK-10

Product Code:

93108740G Description: ELSFS-ERL1-GRAY-10

Product Code:

93092906 Description: ELSFS-ERL1-BLCK-15

Product Code:

93105144G Description: ELSFS-ERL1-GRAY-15

Product Code:

93088130 Description: ELSFS-ERL1-BLCK-20

Product Code:

93088131G Description: ELSFS-ERL1-GRAY-20

ERL2 Shields

Product Code:

93132955G Description: ELSFS-ERL2-BLCK-20

Product Code:

93132986G Description: ELSFS-ERL2-GRAY-20

HOUSE SIDE SHIELDS STREET SIDE SHIELDS

LED.com © 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions.

Cobra Head Shield Guide

PROJECT NAME

DATE TYPE

CATALOG NUMBER

CUSTOMER NAME

FOOTNOTES:

1) 10 = 1" Shield Depth; 15 = 1.5" Shield Depth; 20 = 2" Shield Depth

2) Black is recommended to reduce potential for glare coming off of the shield

3) Use "House Side" Shield to block light trespass behind the pole

4) Use "Street Side" / Front Shield to block light light trespass across the street

ERLC Shields

Product Code:

93132374G Description:

ELS-ERLC-

LEFTRIGHTSIDEKIT-

BLCK-10

SIDE SHIELDS (L&R)

ERL1 SHIELDS

Product Code:

93118695G Description:

ELS-ERL1H-

LEFTRIGHTSIDEKIT-

BLCK-10

ERL2 SHIELDS

Product Code:

93132989G Description:

ELS-ERL2-

LEFTRIGHTSIDEKIT-

BLCK-10

Shipped as a kit - L & R can be used independently

LED.com © 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change without notice. All values are design or typical values when measured under laboratory conditions.

January 2025 20

Appendix C: Voltage Drop Calculations

Financial Project ID: 33831-01 County : COLLIER Service Voltage : 240

State Road Number : SOUTH 1ST STREET Prepared By : NICHOLAS RUSSIN, PE Temp. for Wire Resistance : 75

Project Description : Checked By: JOSH ROBINSON, PE

W.P.I. Number : --- Date: 12/18/2024 WIRE SIZE 25 Deg. C. 40 Deg. C. 75 Deg. C.

(#AWG) (OHMS/FT) (OHMS/FT) (OHMS/FT)

Circuit: A-1 10 0.00101800 0.00107700 0.00129000

8 0.00065400 0.00069200 0.00080900

6 0.00041000 0.00043350 0.00051000

4 0.00025900 0.00027400 0.00032100

2 0.00016200 0.00017150 0.00020100

1/0 0.00010210 0.00010811 0.00012700

FIXTURE WIRE WIRE NUMBER FIXTURE NUMBER CONDUCTOR FIXTURE SEGMENT TOTAL SEGMENT ACCUMULATED

TO LENGTH X 2 SIZE OF SIZE OF RESISTANCE AMPERAGE RESISTANCE AMPERAGE VOLTAGE VOLTAGE

FIXTURE (FEET) WIRES FIXTURES DROP DROP

(L) (AWG) CONDUCTORS (Watts) (r) (i) (R=L*r) (I) (V=I*R) (V1+V2+...)

Load Center A to LP 11 110 6 3 150 1 0.00020100 0.625 0.0221 3.75 0.08 0.08

LP 11 to LP 9 352 6 3 150 1 0.00020100 0.625 0.0708 3.13 0.22 0.30

LP 9 to LP 8 216 6 3 150 1 0.00020100 0.625 0.0434 2.50 0.11 0.41

LP 8 to LP 6 550 6 3 150 1 0.00020100 0.625 0.1106 1.88 0.21 0.62

LP 6 to LP 4 500 6 3 150 1 0.00020100 0.625 0.1005 1.25 0.13 0.75

LP 4 to LP 2 432 6 3 150 1 0.00020100 0.625 0.0868 0.63 0.05 0.80

MAXIMUM VOLTAGE DROP: 0.80

PERCENT VOLTAGE DROP: 0.33%

CONDUCTOR SIZE: O.K.

60 CYCLE AC RESISTANCE ONE WIRE (CU)

ROADWAY LIGHTING VOLTAGE DROP CALCULATIONS

INPUT DATA CALCULATED RESULTS

Customer Name 91:
Page 13:
Page 14:
Page 15:
Page 16:
Page 17:
Page 18:
Project Name 9:
Page 13:
Page 14:
Page 15:
Page 16:
Page 17:
Page 18:
Date 10:
Page 13:
Page 14:
Page 15:
Page 16:
Page 17:
Page 18:
Type 9:
Page 13:
Page 14:
Page 15:
Page 16:
Page 17:
Page 18:
Catalog Number 11:
Page 13:
Page 14:
Page 15:
Page 16:
Page 17:
Page 18:
Check Box 86: Off
Check Box 87: Off
Check Box 88: Off
Check Box 89: Off
Check Box 90: Off
Check Box 91: Off
Check Box 92: Off
Customer Name 46:
Nomenclature 15:
Voltage 73:
Voltage 74:
Voltage 75:
Voltage 84:
Voltage 85:
Voltage 86:
Customer Name 50:
Button 6:
Button 7:
Customer Name 54:
Button 9:
Button 10:
Customer Name 62:
Customer Name 66:
Customer Name 92:
Page 19:
Page 20:
Project Name 10:
Page 19:
Page 20:
Date 11:
Page 19:
Page 20:
Type 10:
Page 19:
Page 20:
Catalog Number 12:
Page 19:
Page 20:
Customer Name 70:
2025-01-03T16:13:10-0500
Scott Samuels
I am approving this document

File details come from the government source that posted it. Updated .