25-26MC Plans.pdf
PDF 21 MB Posted
- Attached to
- City Hall Restroom Renovations
- Solicitation number
- 25-26MC
- Issued by
- Sarasota County, Florida
About this file
These construction documents are for the City of Sarasota City Hall Restroom Renovation project, prepared by Harvard Jolly | PBK Architecture and Global Sanchez, Inc. as the MEP/Systems Engineer. The comprehensive set of plans covers complete renovation of first and second-floor restrooms, including detailed architectural, mechanical, electrical, plumbing, and fire alarm systems documentation. The project involves removing and replacing existing infrastructure in four restroom spaces: male and female public restrooms and male and female staff restrooms on both floors. Specific scope includes replacing mechanical devices, plumbing piping and fixtures, electrical components, and fire alarm systems, with a focus on directional boring for the sanitary line to minimize lobby damage.
The project will utilize the Florida Building Code 8th Edition (2023) and associated referenced codes, with construction documents dated February 6, 2025 and a project number of 24136.00. The renovation will implement new porcelain tile flooring, ceramic tile walls, acoustic ceiling tiles, and new toilet partitions from Scranton Products. Mechanical, electrical, and plumbing work includes updating air distribution systems, electrical devices, lighting controls, and plumbing fixtures to meet current accessibility and energy efficiency standards. The documents indicate careful coordination between disciplines to ensure minimal disruption and compliance with local building and accessibility requirements, with an emphasis on maintaining existing building aesthetics and functionality during the renovation process.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ITB Construction Terms _ Conditions.pdf | ||
| 25-26MC Exhibit B - Minimum Qualifications.pdf | ||
| 25-26MC Exhibit A - Technical Specifications.pdf | ||
| 25-26MC Electronic Bid Form.xls | XLS spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Ft. Myers 239-275-7774 / Jacksonville 904-396-3300 / Orlando 407-667-7727 / St. Petersburg 727-896-4611 / Tampa 813-286-8206 / West Palm Beach 561-478-4457 / AAC013140
Design Office location: 6000 Cattleridge Boulevard, Ste 204, Sarasota, Florida 34232 Ph: 941.954.7632
Architecture - Interior Design - Programming - Planning - Program Management
CITY OF SARASOTA CITY HALL
RESTROOM RENOVATION
1565 1ST ST, SARASOTA, FL 34236
C I T
Y O
F S
A R
A S
O T
A C
I T
Y H
A L
R E
S T
R O
O M
R E
N O
V A
T I O
N
C O
N S
T R
U C
T I O
N
D O
C U
M E
N T
S
H J P
R O
J
.0
S
T S
T
S A
R A
S O
T A
F
L
MEP/FP/SYTEMS ENGINEER:
GLOBAL SANCHEZ, INC.
816 MANATEE AVE EAST, SUITE 18
BRADENTON, FL 34208
www.global-sanchez.com
ARCHITECT
HARVARD JOLLY | PBK
6000 CATTLERIDGE DR, STE 204
SARASOTA, FL 34232
http://www.harvardjolly.com
ARCH. ABBREVIATIONS
EARTH/FILL
BRICK
CONCRETE
CERAMIC TILE
METAL - LARGE SCALE
FINISH WOOD
WOOD BLOCKING
WOOD SHIM
PLYWOOD
GYPSUM WALLBOARD
RIGID INSULATION
BATT INSULATION
CARPET
PREMOLDED JOINT FILLER
SAFING INSULATION
STUCCO, CEMENT
PLASTER,
LIGHTWEIGHT CONCRETE
CMU - LARGE SCALE
CMU - SMALL SCALE
METAL - SMALL SCALE OR
SHEET METAL
JOINT SEALANT AND
BACKER ROD
PROJECT GRAPHIC REFERENCE
DISCIPLINE
CATEGORY
AREA OF BUILDING
FLOOR OF BUILDING
A-101A
NORTH
PROJECT LOCATION
ARCH.GENERAL NOTES
CEMENT PLASTER
SUBCATEGORY
A
A
DOOR SYMBOL
DRAWING / DEMOLITION NOTE
SECTION LETTER
CUTTING LINE
SHEET WHERE LOCATED
REVISION
MATCH LINE
COLUMN AND
CONSTRUCTION GRID LINES
CURTAIN WALL/ STORE FRONTS: (A-
LETTERED).
WINDOWS: (W-LETTERED).
HOLLOW METAL (NUMBERED)
EQUIPMENT DESCRIPT/ #
EXTERIOR/INTERIOR
ELEVATION SYMBOL
DETAIL INDICATION SYMBOL
FLOOR/DATUM
ELEVATION LEVEL
AREA/ITEM
REVISED
0'-0"
FIRST FLOOR
A-501
ELEVATION LETTER
SHEET WHERE LOCATED
A-211
1 1
A
B
A-311
SIM
TOILET ACCESSORY DESCRIPT/ #
XXX
LOUVER
XX-N
1t
88'-8-1/2"
Type Name
Area Rounded
SF
ROOM NAME
ROOM #
P - AREA
Area Rounded
SF
Occu.
Load
ROOM NAME
ROOM #
Type
STC
CEILING HEIGHT/ MATERIAL
WALL TYPE/ STC RATING
FLOOR PLAN ROOM TAG
(Program Area Opt.)
LIFE SAFETY ROOM TAG
# OCCUPANTS THIS ROOM
OCCUPANT LOAD FACTOR
SLOPE
11 D-2
-- MEDICAL EQUIPMENT/#
SIGNAGE
CABINET TAG
CABINET TYPES
B: BASE
F: FULL
W: WALL
TYPE VERSION (Examples)
A: FULL DOOR
B: DOUBLE DOOR
C: RIGHT DOOR
D: LEFT DOOR
CABINET TYPE
TYPE VERSION
Project Specific
CABINET HEIGHT
CABINET WIDTH
SFRM-[N.#]
SPRAYED FIRE RESISTIVE
MATERIAL/ LINE TYPE
GRAVEL
FENCE LINE (VARIES PER PLAN)
9B
.6
103.1
A1
B 24 C 25.25
SHEET NO. SYSTEM
DISCIPLINE
G GENERAL
A ARCHITECTURAL
SUBDISCIPLINE
E EXISTING 0 GENERAL
D DEMO 1 PLANS
S SITE 4 DETAILS
APPLICABLE CODES
BUILDING CODE:
MECHANICAL CODE:
ELECTRICAL CODE:
PLUMBING CODE:
FLORIDA BUILDING CODE (FBC) 8TH EDITION (2023)
FBC-MECHANICAL 8TH EDITION (2023)
FBC-BUILDING, CHAPTER 27; NFPA 70-2020
NATIONAL ELECTRIC CODE (N.E.C)
FBC PLUMBING 8TH EDITION (2023)
CODE EDITIONS REFERENCED BELOW INCLUDE
SUPPLEMENTS AND APPLICABLE AMENDMENTS
ACCESSIBILITY CODE: FBC-ACCESSIBILITY 8TH EDITION (2023): FLORIDA
ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION
EXISTING BUILDING: FBC-EXISTING BUILDING 8TH EDITION (2023)
LOCATION MAP
1. DOCUMENT REVIEW: IT IS THE RESPONSIBILITY OF THE
CONTRACTOR AND EACH OF THE SUBCONTRACTORS TO REVIEW
ALL THE DRAWINGS AND SPECIFICATIONS TO ENSURE
COORDINATION OF ALL THE WORK AFFECTING EACH TRADE.
2. EXISTING CONDITIONS: THE EXISTING CONDITIONS SHOWN ON
THESE DRAWINGS ARE BASED ON INFORMATION PROVIDED TO THE
ARCHITECT. THE CONTRACTOR SHALL VERIFY ALL EXISTING
CONDITIONS AND DIMENSIONS. NOTIFY THE ARCHITECT OF
DEVIATIONS FROM THESE DRAWINGS PRIOR TO FABRICATION AND
INSTALLATION OF THE WORK.
3. EXIT ACCESS: THE CONTRACTOR SHALL MAINTAIN ALL EXISTING
APPROVED MEANS OF EGRESS FOR ALL OCCUPIED SPACES IN
ACCORDANCE WITH THE AUTHORITIES HAVING JURISDICTION.
4. DRAWINGS: THESE DRAWINGS SHALL NOT BE SCALED. REFER TO
DIMENSIONS INDICATED, ACTUAL SIZES OF CONSTRUCTION ITEMS
OR OTHER METHODS OF LOCATING CONSTRUCTION. WHERE NO
DIMENSION OR OTHER METHOD OF DETERMINING A LOCATION IS
GIVEN, VERIFY LOCATION WITH ARCHITECT PRIOR TO INSTALLATION.
5. SPECIFICATIONS: REFER TO THE PROJECT MANUAL FOR GENERAL
REQUIREMENTS AND TECHNICAL SPECIFICATIONS. THE DRAWINGS
AND SPECIFICATIONS ARE COMPLEMENTARY. IF DISCREPANCIES
EXIST BETWEEN THE DRAWINGS AND SPECIFICATIONS, THE MOST
STRINGENT OR COSTLY REQUIREMENT SHALL PREVAIL. NOTIFY THE
ARCHITECT OF ANY DISCREPANCIES TO OBTAIN CLARIFICATION.
6. DIMENSIONS: DIMENSIONS INDICATED ARE TO COLUMN
CENTERLINE, TO FINISH FACE OF INTERIOR METAL STUD
PARTITIONS, TO FACE OF CONCRETE OR MASONRY WALLS, TO
FINISH FACE OF EXTERIOR STUD WALLS AND TO FACE OF CORRIDOR
SIDE FINISH OF CORRIDOR PARTITIONS UNLESS OTHERWISE NOTED.
DIMENSIONS INDICATED AS CLEAR SHALL BE A MINIMUM DIMENSION
FROM FACE TO FACE OF FINISH MATERIALS.
7. COORDINATION: WORK OF ENGINEERING DISCIPLINES IS SHOWN ON
ARCHITECTURAL DRAWINGS FOR COORDINATION PURPOSES ONLY.
REFER TO THE APPROPRIATE ENGINEERING DISCIPLINE DRAWINGS
FOR COMPLETE AND GOVERNING INFORMATION REGARDING THEIR
WORK. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES TO OBTAIN
CLARIFICATION.
8. UNFORESEEN CONDITIONS: THE CONTRACTOR SHALL REPORT ANY
UNFORESEEN CONDITIONS DISCOVERED TO THE OWNER,
ARCHITECT AND AUTHORITIES HAVING JURISDICTION, INCLUDING
THE DISCOVERY OF ANY HAZARDOUS MATERIALS.
9. THROUGH PENETRATIONS AND MEMBRANE PENETRATIONS AT FIRE-
RESISTANCE-RATED AND /OR SMOKE -RATED WALL AND FLOOR
ASSEMBLIES: PENETRATIONS SHALL BE PROTECTED WITH A U.L. OR
OTHER NRTL TESTED AND APPROVED PENETRATION FIRESTOP
ASSEMBLY, OR AS PERMITTED BY THE FLORIDA BUILDING CODE AND
THE FLORIDA FIRE PREVENTION CODE. REFER TO PARTITION NOTES
AND DETAILS AND THE PROJECT MANUAL SPECIFICATIONS.
10. FIRE-RATED JOINT ASSEMBLIES: INTERSECTIONS BETWEEN FIRE-
RATED AND/OR SMOKE-RATED WALLS AND FLOOR/CEILING
ASSEMBLIES SHALL BE PROTECTED BY A U.L. OR OTHER NRTL
TESTED AND APPROVED JOINT ASSEMBLY. REFER TO PARTITION
NOTES AND DETAILS AND THE PROJECT MANUAL SPECIFICATIONS.
11. PERIMETER FIRE CONTAINMENT: JOINTS BETWEEN FLOORS AND
EXTERIOR CURTAIN WALLS SHALL BE FIRE SAFED WITH A U.L. OR
OTHER NRTL TESTED AND APPROVED FIRE CONTAINMENT
ASSEMBLY. FIRE RATING OF THE ASSEMBLY SHALL MATCH THE
FIRE-RESISTANCE-RATING OF THE FLOOR CONSTRUCTION.
12. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE
COORDINATION OF INSTALLATION OF ALL FIRESTOP SYSTEMS
BETWEEN VENDORS AND SUBCONTRACTORS. THE CONTRACTOR
SHALL ENSURE THAT ALL FIRESTOP ASSEMBLIES ARE INSTALLED IN
ACCORDANCE WITH THE U.L. TESTED AND APPROVED ASSEMBLY
DETAILS.
13. IT IS THE INTENT OF THESE DRAWINGS TO PROVIDE SUBSTANTIAL,
FIRE RESISTIVE INSTALLATIONS CONFORMING TO REQUIREMENTS
OF THE INDICATED FIRE TEST AND RECOMMENDATIONS OF
UNDERWRITER'S LABORATORIES, THE GYPSUM ASSOCIATION AND
WALLBOARD MANUFACTURER. INSTALLATIONS NOT CONFORMING
TO THESE STANDARDS SHALL BE CORRECTED AT NO ADDITIONAL
COST TO THE OWNER.
14. PLUMBING FIXTURES OTHER THAN ADA COMPLIANT TOILETS SHALL
BE INSTALLED A MINIMUM OF 15 INCHES FROM THE CENTER OF
FIXTURE TO THE FINISHED SURFACE AN ADJACENT SIDE WALL AND A
MINIMUM OF 30 INCHES TO ANOTHER PLUMBING FIXTURE. REFER TO
TOILET ROOM PLANS, ELEVATIONS AND DETAILS FOR DIMENSIONED
LOCATIONS OF ALL FIXTURES AND TOILET PARTITIONS.
A. REFER TO PLUMBING DRAWINGS AND SPECIFICATIONS FOR
FIXTURES FAUCETS AND FITTINGS INFORMATION.
B. COORDINATE THE INSTALLATION OF SINKS, PLUMBING AND
ELECTRICAL ITEMS IN AND ADJACENT TO CASEWORK.
C. PROVIDE OFFSET TRAP AT LAVATORIES AND SINKS LOCATED
IN CASEWORK WITH ADA FORWARD APPROACH KNEE AND
TOE CLEARANCES INDICATED.
D. PROVIDE A MINIMUM OF 24 INCHES CLEARANCE FOR ACCESS
TO FOOT PEDAL VALVES AT CLINICAL SINKS.
15. THE INSTALLATION OF PLUMBING PIPING, VENT STACKS AND
CONDUITS SHALL BE COORDINATED TO FACILITATE THE
INSTALLATION OF RECESSED TOILET ROOM ACCESSORIES, FIRE
EXTINGUISHER CABINETS AND OTHER RECESSED DEVICES AND
EQUIPMENT.
16. ALL WOOD BLOCKING WITHIN THE BUILDING ENVELOPE SHALL BE
FIRE- RETARDANT-TREATED (FRTW) OR PRESSURE TREATED WHERE
FRTW IS NOT PERMITTED (EXAMPLE: FBCB 453.11). ISOLATE
TREATED WOOD FROM METALS WITH 15# FELT OR PEEL & STICK
MEMBRANE AND UTILIZE NON-CORROSIVE FASTENERS.
17. THE CONTRACTOR SHALL VERIFY CONSTRUCTION IS COMPLETE AND
IN ACCORDANCE WITH THE CONTRACT DOCUMENTS PRIOR TO
INSPECTION BY THE AUTHORITY HAVING JURISDICTION.
MALE FEMALE
BATHTUBS
SHOWERS
DRINKING
FOUNTAIN
OTHER
PLUMBING FIXTURE REQUIREMENTS: FBC PLUMBING CHAPTER 4, TABLE 403.1
WC (URINALS)
MALE FEMALE
LAVATORIES
REQUIRED
8TOTAL
PROVIDED
TOTAL
REQUIRED
-------- -- N/A
N/A 1 PER 100 N/A
TOTAL
OCCUPANTS -
-/2= -- M -- F
BUSINESS
USE:
PROVIDED --3388 2 --
1 PER 25 FOR THE FIRST 50
1 PER 50 FOR REMAINDER
EXCEEDING 50
1 PER 40 FOR THE FIRST 80
1 PER 80 FOR REMAINDER
EXCEEDING 80
C
A T
T L E
R
ID
G E
D R
S
T E
S
A R
A S
O T
A F
L
.9
.7
© 2023 HARVARD JOLLY, INC.
Comm. No:
Date:
Drawn:
TO THE BEST OF MY KNOWLEDGE, THE PLANS
AND SPECIFICATIONS COMPLY WITH THE
MINIMUM BUILDING CODES.
NAME:, LIC. #, DATE:
D
C
B
A
3456 2 1
D
C
B
A
3456 2 1 w w w .H a rv a rd
J o lly
.c o m
A
P R
IN
T
E D
F
IL
E
P A
T H
H R A V A R D J O L L Y
/1
/2
:5 :1
P
M A u to d e s k D o c s /C ity S a ra s o ta
.0
C ity H a ll
R e s tr o o m
R e n o
/A R
-0
C it y H a ll_
R e s tr o o m
R e n o v a ti o n
.r v t
24136
G-000
02/06/25
FAB
S
T S
T
S A
R A
S O
T A
F
L
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
GENERAL PROJECT
INFORMATION
C
IT
Y O
F S
A R
A S
O T
A C
IT
Y
H A
L L
R E
S T
R O
O M
R E
N O
V A
T
IO
N
MEP/FP/SYTEMS ENGINEER:
GLOBAL SANCHEZ, INC.
816 MANATEE AVE EAST, SUITE 18
BRADENTON, FL 34208
www.global-sanchez.com
ARCHITECT
HARVARD JOLLY | PBK
6000 CATTLERIDGE DR, STE 204
SARASOTA, FL 34232
http://www.harvardjolly.com
CENTERLINE
# NUMBER OR POUND
& AND
@ AT
Ø DIAMETER OR ROUND
∠ ANGLE
A.B. ANCHOR BOLT
A.D.O. AUTOMATIC DOOR
OPENER
A.F.F. ABOVE FINISH FLOOR
A.H.U. AIR HANDLER UNIT
A.L. ACOUSTICAL LAY-IN
A.P. ACCESS PANEL
A/C. AIR CONDITION(ING)
ACOUS. ACOUSTIC(AL)
ADJ. ADJUSTABLE,
ADJACENT
AL. ALUMINUM
ALT. ALTERNATE
ANOD. ANODIZED
APPROX. APPROXIMATE
ARCH. ARCHITECT
AUTO. AUTOMATIC
B.G. BUMPER GUARD
B.U.R. BUILT-UP-ROOFING
BLDG. BUILDING
BM. BEAM
BOT. BOTTOM
C.B. CATCH BASIN
C.C.T. CUBICAL CURTAIN
TRACK
C.C.U. CORONARY CARE UNIT
C.F.C.I. CONTRACTOR
FURNISHED CO
C.G. CORNER GUARD
C.I. CAST IRON
C.J. CONTROL JOINT
CL
C.L. CENTER LINE
C.M.U. CONCRETE MASONRY
UNIT
C.O. CASED OPENING
C.S. CONCRETE SEALED
C.S.W. CAVITY SHAFT WALL
C.T. CERAMIC TILE
C.T.S. COMPUTED AXIAL
TOMOGRAPHY
SCANNER
C.T.W. CERAMIC TILE
WAINSCOAT
C.U. CLEAN UTILITY
CAB. CABINET
CER. CERAMIC
CLG. CEILING
CLO. CLOSET
CLR. CLEAR
COL. COLUMN
COM. COMMON
CONC. CONCRETE
CONST. CONSTRUCTION
CONT. CONTINUOUS
CONTR. CONTRACTOR
CORR. CORRIDOR
CP. CARPET
CTR. COUNTER, CENTER
CTSK. COUNTER SUNK
D.A. DELAYED ACTION
D.E. DOUBLE EGRESS
D.F. DRINKING FOUNTAIN
D.R. DRESSING ROOM
DBL. DOUBLE
DEPT. DEPARTMENT
DET. DETAIL
DIA. DIAMETER
DIAG. DIAGONAL
DIM. DIMENSION
DISP. DISPENSER
DN. DOWN
DR. DOOR, DOCTOR
DRW. DRAWER
DWGS. DRAWINGS
E.B. EXPANSION BOLT
E.J. EXPANSION JOINT
E.P. ELECTRICAL
PANELBOARD
E.R. EMERGENCY ROOM,
EMERGENCY RELEASE
E.S. EXPOSED STRUCTURE
E.T. ELAPSED TIME
E.W.C. ELECTRIC WATER
COOLER
EA. EACH
EL. ELEVATION
ELEC. ELECTRICAL
ELEV. ELEVATOR
EMER. EMERGENCY
EQ. EQUAL
EQUIP. EQUIPMENT
EXIST. EXISTING
EXP. EXPANSION
EXT. EXTERIOR
F.A. FIRE ALARM
F.A.C. FIRE ALARM CABINET
F.A.C.P. FIRE ALARM CONTROL
PANEL
F.A.P. FIRE ALARM PULL
STATION
F.C. FURRING CHANNEL
F.D. FLOOR DRAIN, FIELD
DIMENSION
F.E. FIRE EXTINGUISHER
F.E.C. FIRE EXTINGUISHER
CABINET
F.F.E. FINISHED FLOOR
ELEVATION
F.H.C. FIRE HOSE CABINET
F.I. FILM ILLUMINATOR
F.N.D. FEMININE NAPKIN
DISPOSAL
F.N.V. FEMININE NAPKIN
VENDOR
F.R. FIRE RATED
F.W. FLUSH WOOD
FDN. FOUNDATION
FIN. FINISH
FL. FLOOR
FLASH. FLASHING
FLOUR. FLOURESCENT
FPRF. FIRE PROOF(ING)
FR. FRAME
FT. FOOT OR FEET
FTG. FOOTING
FURR. FURRING
FUT. FUTURE
G.B. GRAB BAR
G.C. GENERAL
CONTRACTOR
G.M. GALVANIZED METAL
G.M.L. GALVANIZED METAL
LATH
G.M.S. GALVANIZED METAL
STUD
GA. GAUGE
GAL. GALLON
GALV. GALVANIZED
GND. GROUND
GR. GRADE
GWB. GYPSUM WALLBOARD
GYP. GYPSUM
H.B. HOSE BIB
H.C. HOLLOW CORE,
HANDICAPPED
H.M. HOLLOW METAL
H.PT. HIGH POINT
H.R. HANDRAIL
H.R.S. HEALTH AND
REHABILITATIVE
SERVICES
H.S. HEAT STRENGTHENED
H.S.V. HEAT SEAMED VINYL
H.V.A.C. HEATING, VENTILATION,
& AIR CONDITIONING
HBD. HARDBOARD
HDW. HARDWARE
HDWD. HARDWOOD
HGT. HEIGHT
HORIZ. HORIZONTAL
HR. HOUR
HTG. HEATING
I.C.U. INTENSIVE CARE UNIT
I.D. INSIDE DIAMETER
I.P. ISOLATION PANEL
I.P.S. INSIDE PIPE DIAMETER
I.T. ISOLATION
TRANSFORMER
I.V.T. INTRAVENOUS TRACK
IN. INCH(ES)
INCL. INCLUDE(D)(ING)
INSUL. INSULATION
INT. INTERIOR
INV. INVERT(ED)
JAN. JANITOR
JT. JOINT
K.P. KICK PLATE
K.S. KNEE SPACE
L. LENGTH
L.A. LAY-IN ACOUSTICAL
L.F. LINEAR FEET
L.L. LEAD LINED, LIVE LOAD
L.P. LIGHTPROOF
LAB. LABORATORY
LAM. LAMINATE
LAV. LAVATORY
LBL. LABEL
LKR. LOCKER
LT.WT. LIGHT WEIGHT
M.B. MACHINE BOLT
M.G. MEDICAL GAS
M.G.A. MEDICAL GAS ALARM
M.G.I. MEDICAL GAS OUTLET
M.G.V.B. MEDICAL GAS VALVE
BOX
M.H. MANHOLE
M.O. MASONRY OPENING
M.O.L. MORE OR LESS
M.P. MEDICINE
PREPERATION
M.R. MOISTURE RESISTANT
M.R.I. MAGNETIC RESONANCE
IMAGER
M.S. METAL STUD
M.S.L. MEAN SEA LEVEL
M.T. METAL THRESHOLD
M.V. MIXING VALVE
MAS. MASONRY
MATL. MATERIAL
MAX. MAXIMUM
MDLG. MOULDING
MECH. MECHANICAL
MED. MEDICINE CABINET
MED.
PREP.
MEDICAL PREPERATION
MET. METAL
MFD. MANUFACTURED
MFR. MANUFACTURER
MIN. MINIMUM
MISC. MISCELLANEOUS
MTD. MOUNTED
MUL. MULLION
SHEET
ISSUE
DATE DESCRIPTION
Revision
Revision Description
Revision Date
COVER
COVER 02/06/25 COVER SHEET
GENERAL
G-000 02/06/25 GENERAL PROJECT INFORMATION
ARCHITECTURAL DEMOLITION
AD-100 02/06/25 ARCHITECTURAL EXISTING AND DEMO PLAN, WALL TYPES
ARCHITECTURAL
A-101 02/06/25 FIRST FLOOR PLANS AND INTERIOR ELEV
A-410 02/06/25 TYPICAL TOILET & SHOWER ROOM DETAILS
MECHANICAL
M0.0 02/06/25 MECHANICAL DOCUMENTATION
M0.1 02/06/25 MECHANICAL GENERAL
M2.1 02/06/25 MECHANICAL DEMO 1ST FLOOR PLAN
M2.2 02/06/25 MECHANICAL DEMO 2ND FLOOR PLAN
M4.1 02/06/25 MECHANICAL PROPOSED 1ST FLOOR PLAN
M4.2 02/06/25 MECHANICAL PROPOSED 2ND FLOOR PLAN
ELECTRICAL
E0.0 02/06/25 ELECTRICAL DOCUMENTATION
E0.1 02/06/25 ELECTRICAL GENERAL
E0.2 02/06/25 ELECTRICAL SPECIFICATIONS
E4.1 02/06/25 ELECTRICAL PROPOSED 1ST FLOOR LIGHTING PLAN
E4.2 02/06/25 ELECTRICAL PROPOSED 2ND FLOOR LIGHTING PLAN
PLUMBING
P0.0 02/06/25 PLUMBING DOCUMENTATION
P0.1 02/06/25 PLUMBING GENERAL
P2.1 02/06/25 PLUMBING DEMO PLAN
P4.1 02/06/25 PLUMBING PROPOSED SANITARY PLAN
P5.1 02/06/25 PLUMBING PROPOSED WATER PLAN
P9.1 02/06/25 PLUMBING DETAILS
FIRE PROTECTION
FA0.0 02/06/25 FIRE ALARM DOCUMENTATION
FA0.1 02/06/25 FIRE ALARM GENERAL
FA4.1 02/06/25 FIRE ALARM PROPOSED 1ST FLOOR PLAN
FA4.2 02/06/25 FIRE ALARM PROPOSED 2ND FLOOR PLAN
FA8.1 02/06/25 FIRE ALARM RISER DIAGRAMS
Revisions
No. Date Revision
Description
N.C. NURSE CALL
N.I.C. NOT IN CONTRACT
N.STA. NURSE STATION
N.T.S. NOT TO SCALE
NO. NUMBER
NOM. NOMINAL
O.A. OVERALL
O.C. ON CENTER
O.D. OUTSIDE DIAMETER,
OVERALL DIMENSION
O.F.C.I. OWNER FURNISHED
CONTRACTOR
INSTALLED
O.F.O.I. OWNER FURNISHED
OWNER INSTALLED
O.H. OVERHEAD, OPPOSITE
O.H. CAB. OVERHEAD CABINET
O.R. OPERATING ROOM
O.S. OVERFLOW SCUPPER
OPNG. OPENING
OPP. OPPOSITE
P. PAINT
P.T. PRESSURE TREATED
P.T.D. PAPER TOWEL
DISPENSER
P.V.C. POLYVINYL CHLORIDE
PF. PREFABRICATED
PL. PLATE, PLASTIC
LAMINATE
PLAS. PLASTER
PLYWD. PLYWOOD
POL. POLISHED
PR. PAIR
PT. POINT
PTN PARTITION
S.A.B. SOUND ATTENUATING
BLANKET
S.C. SOLID CORE
S.D. SOAP DISPENSER
S.F., SQ.
FT.
SQUARE FOOT (FEET)
S.M. SHEET METAL
S.M.S. SHEET METAL SCREW
S.P.B. SPECIMEN PASS BOX
S.S. STAINLESS STEEL
S.U. SOILED UTILITY
S.Y. SQUARE YARD
SCHED. SCHEDULE
SEAL. SEALANT
SECT. SECTION
SH. SHELVING, SHELF
SHT. SHEET
SIM. SIMILAR
SPEC. SPECIFICATION(S)
SPF. SOUNDPROOF
STA. STATION
STD. STANDARD
STL. STEEL
STOR. STORAGE
STRL. STRUCTURAL
SUSP. SUSPENDED
T. TREAD, TOILET
T.&G. TONGUE & GROOVE
T.B. TEST BORING
T.C. TOILET COMPARTMENT
T.P.D. TOILET PAPER
DISPENSER
T.P.H. TOILET PAPER HOLDER
T.V. TELEVISION
TA. TABLE
TEL. TELEPHONE
TEMP. TEMPERED,
TEMPERATURE
THK. THICK(NESS)
TREAT. TREATMENT
TYP. TYPICAL
U.C. UNDERCOUNTER
U.O.N. UNLESS OTHERWISE
NOTED
UC. UNDERCUT
UTIL. UTILITY
V. VINYL
V.B. VINYL BASE
V.C.T. VINYL COMPOSITION
TILE
V.I.F. VERIFY IN FIELD
V.W.C. VINYL WALL COVERING
VERT. VERTICAL(LY)
VEST. VESTIBULE
W.B. WALL BUMPER
W.C. WATER CLOSET, WALL
COVERING
W.H. WATER HEATER
W.I. WROUGHT IRON
W.O. WHERE OCCURS
W.P. WATERPROOF(ING)
W.R. WASTE RECEPTACLE
W.W.F. WELDED WIRE FABRIC
W.W.M. WELDED WIRE MESH
W/ WITH
W/C WHEEL CHAIR
W/O WITHOUT
WD. WOOD
WT. WEIGHT
02/10/25
1. SITE VISIT - PRIOR TO STARTING WORK, CONTRACTOR SHALL
VISIT THE PROJECT SITE AND THOROUGHLY BECOME FAMILIAR
WITH EXISTING CONDITIONS. NO CLAIMS FOR ADDITIONAL
WORK DUE TO OBSERVABLE CONDITIONS WILL BE CONSIDERED.
2. DEMOLITION WORK - CARRY OUT DEMOLITION WORK TO CAUSE
AS LITTLE INCONVENIENCE TO ADJACENT OCCUPIED BUILDING
AREAS. DEMOLISH IN AN ORDERLY AND CAREFUL MANNER AS
REQUIRED TO ACCOMMODATE NEW WORK. PERFORM
DEMOLITION IN ACCORDANCE WITH APPLICABLE AUTHORITIES
HAVING JURISDICTION. TAKE CARE TO PREVENT DAMAGE AND
EXCESSIVE NOISE OR VIBRATION SO AS TO NOT DISTURB
ADJACENT OCCUPIED AREAS. ANY OPERATION THAT MAY
CAUSE DISTURBANCE TO OWNER'S FUNCTIONING OPERATION
OF THE PROJECT SHALL BE COORDINATED WITH THE OWNER AT
A MUTUALLY AGREED UPON REGULAR ADVANCED TIMELINE OR
AS SPECIFIED. SOME WORK MAY REQUIRE 'OFF HOURS' FROM
OWNER OCCUPIED AREAS TO ALLOW FOR OWNER'S NORMAL
OPERATIONAL HOURS' USE.
3. SCHEDULING - SCHEDULE DEMOLITION WORK WITH FACILITY
ADMINISTRATION/ OWNER PRIOR TO START OF THE WORK TO
MINIMIZE DISRUPTION OF SERVICES AND PROVIDE FOR THE
UNINTERRUPTED FUNCTIONING OF THE FACILITY AS
APPLICABLE.
4. PROTECTION - EXERCISE CARE DURING WORK TO PROTECT
EXISTING ELEMENTS AND SYSTEMS. REPAIR TO EXISTING
CONSTRUCTION DUE TO DAMAGE CAUSED BY PERFORMING THE
WORK SHALL BE PERFORMED AT NO COST TO THE OWNER.
5. HAZARDOUS MATERIALS - THE CONTRACTOR SHALL
IMMEDIATELY REPORT ANY HAZARDOUS OR TOXIC MATERIALS
DISCOVERED TO ARCHITECT, OWNER, AND AUTHORITIES
HAVING JURISDICTION.
6. WHERE OPENINGS ARE CREATED IN EXISTING CONSTRUCTION
TO REMAIN, VISIBLE EDGES OF THE OPENING SHALL BE
FINISHED TO A MATCHING CONDITION OF SIMILAR EXISTING
OPENINGS IN THE AREA OF WORK.
7. WHERE DOORS OR WINDOWS OR SYSTEMS IN AN EXISTING
OPENING ARE REMOVED, REMOVE ALL NON STRUCTURALLY
ELEMENTS SUCH THAT WILL ALLOW FOR REQUIRED INFILL
WALLS ALIGNED TO BE FINISHED AND MATCHED FLUSH ON
BOTH VISIBLE SIDES OF ADJACENT WALLS U.O.N.
8. WHERE EXISTING MECHANICAL, PLUMBING, ELECTRICAL, FIRE
PROTECTION, AND MED GAS SYSTEMS ARE AFFECTED BY
DEMOLITION WORK, THE SERVICES SHALL BE REMOVED TO A
POINT WHERE THEY CAN BE CAPPED AND TERMINATED U.O.N.
9. WHERE NEW FINISHES ARE SCHEDULED FOR EXISTING OR
RENOVATED SPACES, REMOVE EXISTING FINISHES AND
PREPARE SUBSTRATES AS REQUIRED TO RECEIVE NEW
FINISHES AS SCHEDULED. PREPARATION INCLUDES BUT IS NOT
LIMITED TO: PATCHING AND/ OR LEVELING OF FLOORS, SKIM
COATING OF GYPSUM AND PLASTER SURFACES, SANDING OF
NON-PRE-FINISHED METALS.
10. CUTTING AND PATCHING REQUIRED FOR THE INSTALLATION OF
WORK OF OTHER TRADES SHALL BE PROVIDED AT NO
ADDITIONAL COST TO THE OWNER. REFER TO MECHANICAL,
PLUMBING, ELECTRICAL, FIRE PROTECTION, AND MEDICAL GAS
DRAWINGS AS APPLICABLE. SUCH CUTTING AND PATCHING
INCLUDES BUT IS NOT LIMITED TO ROOF PENETRATIONS AND
FLASHINGS, CEILING REMOVAL AND REPLACEMENT, DRYWALL
AND MASONRY PARTITIONS, CONCRETE FLOORS ETC.
11. WHERE DEMOLITION WOULD AFFECT THE STRUCTURAL
INTEGRITY OF THE BUILDING, PROVIDE TEMPORARY SUPPORTS.
CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY FOUND
CONDITION WHICH WOULD REPRESENT A HAZARDOUS
CONDITION TO THE STRUCTURE OR ITS OCCUPANTS BEFORE
PROCEEDING. DO NOT PERFORM STRUCTURAL DEMOLITION
UNTIL APPROVED MEANS OF SUPPORTS IS INSTALLED.r
12. WHERE EXISTING CEILINGS ARE REMOVED, TAKE CARE TO
REMOVE ONLY THAT PORTION SO INDICATED TO BE REMOVED.
13. FOR AREAS WHERE WORK REQUIRES ACCESS ABOVE THE
CEILING. IN THESE AREAS REMOVE AND REPLACE THE CEILING
AS NECESSARY FOR ACCESS TO WORK. MATCH EXISTING
CEILING AND FINISHES UPON COMPLETION OF WORK IN THESE
AREAS.
14. FLOORS - CONTRACTOR SHALL FIELD VERIFY LEVELNESS OF
EXISTING FLOOR SLABS AFTER COMPLETION OF DEMOLITION
WORK AND BRING TO THE ARCHITECT'S ATTENTION ANY
DEVIATION FROM SPECIFIED TOLERANCES. ANY CORRECTIVE
WORK SHALL BE ACCOMPLISHED PRIOR TO NEW
CONSTRUCTION.
15. EQUIPMENT COORDINATION - CONTRACTOR SHALL BE
RESPONSIBLE FOR PROTECTION OF ALL EXISTING FINISHES,
FURNITURE, AND EQUIPMENT TO REMAIN IN AREAS WHERE
CONSTRUCTION FOR THIS PROJECT OCCURS. OWNER AND
CONTRACTOR SHALL COORDINATE PRIOR TO CONSTRUCTION
FOR ANY SYSTEM/ DEVICE/ EQUIPMENT THE OWNER PREFERS
TO MOVE INCLUDING ITS STORAGE REQUIREMENTS.
16. DEMOLITION NOTES - NUMBERED NOTES BELOW ARE
SUMMARIZED FOR SYSTEMS TO BE DEMOLISHED. THESE ARE
NOT CONSIDERED TO BE ALL-INCLUSIVE OR COMPLETE IN OF
THEMSELVES. PERFORM ADDITIONAL DEMOLITION THAT MIGHT
REASONABLY BE REQUIRED FOR PREPARATION OF INSTALLING
NEW WORK AND SPECIFIED FINISHES.
17. ALL EXISTING RESTROOM WALLS HAVE FLOOR TO CEILING TILE
WHICH SHALL BE REMOVED.
DEMOLITION NOTES
1. REMOVE EXISTING METAL STUD WALLS & FINISHES
2. REMOVE EXISTING PLUMBING FIXTURES, ACCESSORIES,
AND TOILET PARTITIONS
3. REMOVE EXISTING DOOR AND REUSE - REFINISH
4. REMOVE EXISTING DOOR
5. REMOVE EXISTING DRYWALL CEILING (FOR FIRST LEVEL
RESTROOM)
6. REMOVE EXISTING ACOUSTICAL CEILING TILE & GRID
(FOR SECOND LEVEL RESTROOM)
7. REMOVE MASONRY WALL & FINISHES
8. REMOVE EXISTING TILE FLOOR TO SUBSTRATE
9. REMOVE EXISTING JANITOR MOP SINK
D-_DEMOLITION DRAWING NOTES:
AD-100 5
AD-1006
D-3D-3
D-3 D-1
D-4
D-4
D-1
D-2
D-2
D-7
D-4D-1
D-1
D-7
D-1 D-4
D-2
D-3D-3
D-2D-9
D-7
D-8
D-8
D-8
D-8
AD-100 7 AD-100 8
D-7
D-2
D-3
D-2
D-1
D-2
D-1
D-3
D-4 D-4
D-8
D-8
D-2 D-1 D-2 D-7
D-2
D-2 D-5
D-8
D-2
D-4
D-2 D-7
D-2
D-4 D-5
D-8
D-2 D-2 D-6D-4
D-8
D-2 D-2 D-6D-4
D-8
7' - 8"
7' - 8"
4 5/128"
9' - 2" 9' - 2"
2' - 7"
6"2' - 9"
6' - 7"
BASE AS
SCHEDULED
FLOOR FINISH
AS SCHEDULED
ATTACH RUNNER
TO SLAB 4' - 0" O.C.
MIN.
EXTEND WALL PARTITION
TO UNDERSIDE OF
CONCRETE BEAM,
CONCRETE DECK, STEEL
BEAM, STEEL DECK, OR
COPING AS APPLICABLE,
PACK WITH ACOUSTIC
FIBERGLASS MATERIAL
AND SEAL WITH
ACOUSTIC SEALANT TO
ACHIEVE COMPLETE
CLOSURE
2 LAYERS 5/8" x 48"
WIDE CEMENT BOARD
OVER METAL STUDS
AT 1' - 4" O.C.
W1 - WETWALL WITH 2-LAYER 5/8" FCB ON 3 5/8" METAL
STUD ON ONE SIDE
3 1/2" SOUND
ATTENUATION BLANKET
5/8" GYP BOARD OVER 1
5/8" METAL FRAMING AT
16" O.C. REFER TO RCP
FOR HEIGHT AND FINISH
U.N.O.
3 5/8"
U.N.O.
3 5/8"
EXISTING
CONT. ACOUSTIC
SEALANT
FLOOR FINISH
AS SCHEDULED
BASE AS
SCHEDULED
4" OR 6" METAL STUDS
AT 16" O.C.
5/8" x 48" WIDE FIBER
CEMENT BOARD
APPLIED VERT. (BOTH
SIDES)
S1B - 1-LAYER 5/8" FCB ON 7/8" METAL HAT CHANNEL ON ONE SIDE
S4A - 1-LAYER 5/8" FCB ON 4" METAL STUD ON BOTH SIDES
S4B - 1-LAYER 5/8" FCB ON 4" METAL STUD ON ONE SIDE
S6A - 1-LAYER 5/8" FCB ON 6" METAL STUD ON BOTH SIDES
SOUND BATT
INSULATION
C
A T
T L E
R
ID
G E
D R
S
T E
S
A R
A S
O T
A F
L
.9
.7
© 2023 HARVARD JOLLY, INC.
Comm. No:
Date:
Drawn:
TO THE BEST OF MY KNOWLEDGE, THE PLANS
AND SPECIFICATIONS COMPLY WITH THE
MINIMUM BUILDING CODES.
NAME:, LIC. #, DATE:
D
C
B
A
3456 2 1
D
C
B
A
3456 2 1 w w w .H a rv a rd
J o lly
.c
P R
IN
T
E D
F
IL
E
P A
T H
H R A V A R D J O L L Y
/1
/2
:5 :1
P
M A u to d e s k D o c s /C ity S a ra s o ta
.0
C ity H a ll
R e s tr o o m
R e n o
/A R
-0
C it y H a ll_
R e s tr o o m
R e n o v a ti o n
.r v t
24136
AD-100
02/06/25
FAB
S
T S
T
S A
R A
S O
T A
F
L
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
ARCHITECTURAL
EXISTING AND DEMO
PLAN, WALL TYPES
C
IT
Y O
F S
A R
A S
O T
A C
IT
Y
H A
L L
R E
S T
R O
O M
R E
N O
V A
T
IO
N
1/4" = 1'-0"
1 EXISTING FIRST FLOOR PLAN
1/4" = 1'-0"
2 EXISTING SECOND FLOOR PLAN
1/4" = 1'-0"
3 DEMOLITION PLAN FIRST FLOOR
1/4" = 1'-0"
4 DEMOLITION PLAN SECOND FLOOR
1/4" = 1'-0"
5 FIRST FLOOR MALE RESTROOM INT. ELEV.
1/4" = 1'-0"
6 FIRST FLOOR FEMALE RESTROOM INT. ELEV.
1/4" = 1'-0"
7 SECOND FLOOR MALE RESTROOM INT. ELEV.
1/4" = 1'-0"
8 SECOND FLOOR FEMALE RESTROOM INT. ELEV.
1 1/2" = 1'-0"
S1B/S4A/S4B/S6A 1 1/2" = 1'-0"
W1
Revisions
No. Date Revision
Description
A-101 4
A-1017
FEMALE PUBLIC
RESTROOM
/2
7' - 8"
4"
/2
A-101 5
A-1018
MALE PUBLIC
RESTROOM
FEMALE STAFF
RESTROOM
MALE STAFF
RESTROOM
/8
/2
S4A
S4A S4A
S4A
S4A
S6A
S4A
S4A
S6A
/8
1 1
W1
S1B
S1B
S1B
3' - 10"
S6A
7' - 8"
4"
/2
3' - 0"
4' - 6"
2' - 6"
2' - 6"
S1B
S1B
S4A
S1B
4' - 6"
S6A
S4B
6"
CT1/2/3
CT1/2/3
SS1
CT1/2/3
TP
CT1/2/3
SS1
7' - 6"
EQ 4' - 0" EQ
E Q
E Q
EQ 4' - 0" EQ
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
EQ 4' - 0" EQ
E Q
E Q
E Q
E Q
7' - 6"
7' - 6"
EQ 4' - 0" EQ
8'-4"
GWB 8'-10"
ACT1
8'-4"
GWB
8'-4"
GWB 8'-10"
ACT1
8'-4"
GWB
8'-10"
ACT1
8'-10"
ACT1 E
Q
E Q
E Q
E Q
8'-4"
GWB
CT1/2/3
SS1
EP1CT1/2/3
SS1
1. COLORS AND PATTERNS SHALL BE AS SELECTED BY THE
ARCHTIECT OR INTERIOR DESIGNER
2. SEE TOILET ROOM ELEVATIONS FOR PAINT, CERAMIC TILE (CT)
WALL AND PORCELAIN TILE (PT) FLOOR PATTERN LAYOUTS.
3. TILE EDGES TO RECEIVE METAL EDGE BAND.
FINISH SCHEDULE REMARKS
FLOORING
A. EXISTING TO REMAIN - X
B. PORCELAIN TILE
1. PT1 MANUFACTURER: TBD
PRODUCT: TBD
COLOR: TBD
SIZE: TBD
PATTERN: TBD
INSTALLATION: TBD
BASE
A. EXISTING TO REMAIN - X
B. PORCELAIN TILE
1. PT1 MANUFACTURER: TBD
PRODUCT: TBD
COLOR: TBD
SIZE: TBD
WALLS
A. EXISTING TO REMAIN - X
B. CERAMIC TILE
1. CT1 MANUFACTURER: DALTILE
SERIES: COLOR WHEEL LINEAR
COLOR : BISCUIT 0091
SIZE: 4" X 16"
1. CT1 MANUFACTURER: DALTILE
SERIES: COLOR WHEEL LINEAR
COLOR : DESERT GRAY X114
SIZE: 4" X 16"
1. CT1 MANUFACTURER: DALTILE
SERIES: COLOR WHEEL LINEAR
COLOR : URBAN PUTTY DT 0161
SIZE: 4" X 16"
C. EPOXY PAINT
1. EP MANUFACTURER: TBD
PRODUCT: TBD
COLOR : TBD
SIZE: TBD
CEILINGS
A. ACOUSTICAL CEILING TILE SYSTEM
1. ACT1 MANUFACTURER: ARMSTRONG
PRODUCT: ACOUSTIC CEILING PANEL
SERIES: CASTWORKS METAPHOR
DESIGN: TIDAL WITH FLAT AREA
COLOR: WHITE (WH)
SIZE: 24" X 24"
MISCELLANEOUS:
A. QUARTZ SOLID SURFACE
1. SS1 MANUFACTURER: FORMICA
PATTERN: WHITE RENEW 748
LOCATION: BREAK ROOM/ RESTROOM
COUNTERTOP
B. TOILET PARTITION
1. TP MANUFACTURER: SCRANTON PRODUCTS
COLOR: CONCRETE
TEXTURE: ORANGE PEEL
FINISH MATERIAL LEGEND
DIFFUSER GRILLE (REFER TO MECH. DRAWINGS).
EXHAUST GRILLE (REFER TO MECH. DRAWINGS).
GYPSUM WALL BOARD CEILING SYSTEM
RECESS DOWNLIGHT. SEE LIGHTING SPEC.
F/A SMOKE DETECTOR (REFER TO
ELECTRICAL DRAWINGS).
F/A HEAT DETECTOR (REFER TO
ELECTRICAL DRAWINGS).
RETURN AIR GRILLE (REFER TO MECH. DRAWINGS).
INDICATES CEILING HEIGHT AFF IN FEET AND INCHES
& INDICATES CEILING TYPE
REFLECTED CEILING LEGEND
88'-8-1/2"
Type Name
1. REFER ALSO TO MECHANICAL ELECTRICAL DRAWINGS
FOR ADDITIONAL CRITERIA ON ABOVE SYSTEMS AS
APPLICABLE
2. CENTER SYSTEMS IN CEILINGS ADJACENT TO DOORS
ON CENTER OF DOORS OR CENTER OF NEAREST LAY-IN
CEILING TILES
3. IT IS THE INTENT OF THE CEILING DESIGN TO HAVE
VISIBLE DEVICES ALIGNED IN FINISHED AREAS TO THE
GREATEST EXTENT POSSIBLE U.O.N. AND TO BE
CENTERED ON CENTER OF LAY-IN CEILING SYSTEMS
U.O.N.
4. CEILING HEIGHTS - SHALL BE AS NOTED ON PLAN.
WHERE ABUTTING EXISTING CEILINGS, HEIGHT SHALL
MATCH EXISTING AT ADJACENT LOCATIONS, U.O.N.
5. GRILLES, DIFFUSERS, REGISTERS - COORDINATE
REFLECTED CEILING PLANS AND MECHANICAL PLANS.
CONFLICTS SHALL BE RESOLVED PRIOR TO
INSTALLATION.
6. FOR FIXTURES - COORDINATE REFLECTED CEILING
PLAN AND ELECTRICAL LIGHTING PLAN. CONFLICTS
SHALL BE RESOLVED PRIOR TO INSTALLATION.
7. SUPPORT - DO NOT HANG SYSTEMS FROM EXISTING OR
NEW METAL DECKING. CONNECT OR SUSPEND ONLY
FROM STRUCTURAL MEMBERS OR MEMBERS THAT ARE
SECURED TO THE STRUCTURE.
8. ACOUSTICAL TILE SUPPORT - WHENEVER ITEMS SUCH
AS SMOKE DETECTORS, SIGNAGE, SPEAKERS, ETC.
ARE ATTACHED TO CEILING TILES, PROVIDE CROSS
BRACE SUPPORT SECURED TO EACH SIDE OF ITEM.
BRACE SHALL BE LOCATED TO PROVIDE FULL SUPPORT
OF ITEM INDEPENDENTLY OF TILE WITHOUT ANY SAG,
BOW OR TWIST OF CEILING OR GRID.
9. EXISTING CEILING COORDINATION: AT AREAS WITH
EXISTING CEILINGS EXTENDED INTO NEW AREAS
WHERE REQUIRED BY NEW CONSTRUCTION, ATTEMPT
TO MATCH EXISTING CONSTRUCTION, TYPE, COLOR
AND SPACING OF GRID, ETC. TAKE CARE NOT TO
DAMAGE EXISTING CEILINGS TO BE REUSED OR
EXTENDED. REPAIR OR REPLACE AREAS DAMAGED BY
CONSTRUCTION ACTIVITIES AT NO ADDITIONAL COST
TO THE OWNER.
10. THE EXTENT OF THE CEILING WORK IS INTENDED TO BE
ALL INCLUSIVE. REFER ALSO TO MECHANICAL AND
ELECTRICAL DRAWINGS.
S
H
NOTES
ACOUSTIC CEILING PANEL
DESCRIPTION
ITEM
BY
CFCI
CFCI
CFCI
CFCI
CFCI
CFCI
36" REAR GRAB BAR
MIRROR (WIDTH TO BE THE SPACE ON THE WALL)
RECESSED PAPER TOWEL DISPENSER
SOAP DISPENSER
SANITARY NAPKIN DISPOSAL WITH TOILET PAPER
DISPENSER COMBO
TOILET PAPER DISPENSER
NOTES:
1. CONTRACTOR TO FURNISH AND INSTALL CONCEALED WOOD BLOCKING
(WITHIN WALLS) AS REQUIRED TO FIRMLY SECURE WALL-MOUNTED
EQUIPMENT AND/OR ACCESSORIES. ALL WOOD BLOCKING IN CONTACT WITH
MASONRY IS TO BE PRESSURE TREATED.
CFCI: CONTRACTOR FURNISH AND INSTALL
OFCI: OWNER FURNISH AND CONTRACTOR INSTALL
OFOI: OWNER FURNISH AND OWNER INSTALL
2. ALL EXPOSED PIPING AT LAVATORIES SHALL BE INSULATED WITH HANDI
LAV-GUARD OR APPROVED EQUAL, WHITE.
3. ALL TOILET PARTITION DOORS TO HAVE ROBE HOOKS.
GB-1
MIR
PTD
SD
SND
TPH
ACCESSORIES LEGEND
XX-N
CFCI42" SIDE GRAB BARGB-2
CFCI
CFCI
BABY CHANGING TABLE KOALA KARE #KB200
RECESSED TRASH BIN
BCT
TRB
CFCITOILET SEAT COVER DISPENSERTSC
1. EXTERIOR MASONRY DIMENSIONS ARE FROM
FACE OF MASONRY UNIT TO FACE OF MASONRY
UNIT.
2. MASONRY OPENING DIMENSIONS ARE FROM FACE
OF MASONRY UNIT TO FACE OF MASONRY UNIT.
3. INTERIOR DIMENSIONS ARE FROM FACE OF FINISH
TO FACE OF FINISH.
4. LOCATE OPENINGS IN STUD PARTITIONS 6” FROM
ADJACENT PARTITIONS. U.N.O.
5. LOCATE OPENINGS IN INTERIOR MASONRY
PARTITIONS 8” FROM ADJACENT MASONRY
INTERIOR PARTITIONS. U.N.O.
ABBREVIATION CONVENTIONS:
M.O. = MASONRY OPENING
R.O. = ROUGH OPENING
CLEAR = CLEAR OPENING
V.I.F. = VERIFY IN FIELD
=/- = PLUS/MINUS
C.L. = CENTER LINE
ALIGN = LINE UP
TYP. = TYPICAL
CONT. = CONTINUOUS
MIN. = MINIMUM
P.O.B. = POINT OF BEGINNING
DIMENSIONING CONVENTIONS:
1. STC RATINGS INDICATED ARE SOURCED FROM THE LATEST
EDITION OF THE GYPSUM ASSOCIATION (GA-600) SOUND
CONTROL MANUAL.
2. U.L DESIGN NO.’S INDICATED ARE SOURCED FROM THE
LATEST EDITION OF THE UNDERWRITERS LABORATORIES
INC. (FIRE RESISTANCE) DIRECTORY.
3. ALL PARTITIONS ARE TYPE __________ U.N.O.
4. ALL GYPSUM BOARD SHALL BE TYPE X U.N.O.
5. STAGGER ELECTRICAL BOXES AND OTHER DEVICES IN
ACOUSTICAL PARTITIONS 16” MINIMUM.
6. DEVICES AND EQUIPMENT INSTALLED IN FIRE RATED
PARTITIONS SHALL NOT COMPROMISE THE FIRE
RESISTANCE INTEGRITY OF THE PARTITION.
7. ANY PARTITION REQUIRED TO HAVE PROTECTED OPENINGS
OR PENETRATIONS SHALL BE EFFECTIVELY AND
PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING IN
THE CONCEALED SPACE IN ACCORDANCE WITH FBC (6TH
Ed.) 703.7.
8. PROVIDE METAL SUPPORT IN PARTITIONS TO RECEIVE
WALL MOUNTED EQUIPMENT, CABINETS, HANDRAILS,
ACCESSORIES, ETC.
NUMBER INDICATES PARTITION CORE NOMINAL THICKNESS
LETTER INDICATES PARTITION MODIFIER
M8A
PARTITION TAGS:
LETTER INDICATES PARTITION CORE MATERIAL
PARTITION TYPES GENERAL NOTES:
1. FIRE RESISTANCE - MAINTAIN INTEGRITY OF EXISTING FIRE
AND/OR SMOKE PARTITIONS THROUGHOUT, UNLESS
NOTED OTHERWISE. MAINTAIN INTEGRITY OF ALL EXISTING
FIREPROOFING, FIRESTOPPING, COLUMN ENCLOSURES,
ETC. TO ENSURE FIRE RESISTANCE MEETS OR EXCEEDS
THAT ORIGINALLY REQUIRED OR SPECIFIED. PATCH ALL
AREAS DAMAGED OR REMOVED DUE TO NEW
CONSTRUCTION TO MATCH THAT OF THE EXISTING OR AS
REQUIRED FOR NEW.
2. FINISHES - ALL EXISTING FINISHES SHALL REMAIN, UNLESS
SCHEDULED FOR NEW. CONTINUE EXISTING FINISHES TO
REMAIN INTO NEW EXTENDED AREAS THAT ARE ADJACENT.
PATCH & REPAIR EXISTING TO MATCH NEW. PREPARE
SUBSTRATES TO RECEIVE NEW FINISHES WHERE
SCHEDULED. FINISH ALL PATCHED OR EXTENDED WALLS
TO NEAREST CHANGE OF DIRECTION, WALL TERMINATION,
OR INTERSECTION PHASING - COORDINATE EQUIPMENT
DELIVERIES AND INSTALLATION WITH THE PHASING PLAN
FOR APPROPRIATE SCHEDULING.
3. CONFLICTS - ANY CONFLICT FOUND WITH EXISTING
CONDITIONS AND REQUIREMENTS FOR NEW
CONSTRUCTION SHALL BE IMMEDIATELY BROUGHT TO THE
ATTENTION OF THE ARCHITECT. IF THE CONFLICT AFFECTS
THE PROGRESS OF THE WORK, VERIFY WITH ARCHITECT
SOLUTION NECESSARY PRIOR TO PROCEEDING WITH THAT
PORTION OF THE WORK AND IN A TIMELY FASHION SO AS
NOT TO DELAY THE WORK. COORDINATE ALL TRADES TO
ASCERTAIN NO FURTHER WORK WILL BE IMPACTED BY THE
CONFLICT, OR ITS SOLUTION.
4. REFER TO FINISH SCHEDULE LEGEND FOR ALL WALL
PROTECTION TYPE DEFINITIONS.
FLOOR PLAN NOTES:
NEW CMU WALLS.
FURRING/FACING CONDITIONS MAY
VARY BY TYPE
NEW STUD WALLS. FACING
CONDITIONS MAY VARY BY TYPE
CONC WALLS
EXISTING WALLS.
WALLS LEGEND
PLAN NOTES: NUMBERED ITEMS NN
1. EXISTING DOOR TO BE REUSED
2. EXISTING TELECOM SYSTEM TO BE REATTACHED ON THIS WALL
3. FILL EXISTING WALL PENETRATION
4. NEW DRINKING FOUNTAIN AND WATER REFILLING STATION
5. NEW JANITOR MOP SINK
FEMALE PUBLIC
RESTROOM101
MALE PUBLIC
RESTROOM
FEMALE STAFF
RESTROOM
MALE STAFF
RESTROOM
SD
PTD
SD
PTD
TPH
SD
TPH
GB-1GB-2
PTD
SD
SD
PTD
PTD
MIR
MIR
MIR
MIR
TRB
SND
SND
GB-1
SND
GB-2
PTD
SD
SND
SND
TRB
TRB
BCT
BCT
TRB
TSC
TSC
TSC
TSC
TSC
TSC
TSC
C
A T
T L E
R
ID
G E
D R
S
T E
S
A R
A S
O T
A F
L
.9
.7
© 2023 HARVARD JOLLY, INC.
Comm. No:
Date:
Drawn:
TO THE BEST OF MY KNOWLEDGE, THE PLANS
AND SPECIFICATIONS COMPLY WITH THE
MINIMUM BUILDING CODES.
NAME:, LIC. #, DATE:
D
C
B
A
3456 2 1
D
C
B
A
3456 2 1 w w w .H a rv a rd
J o lly
.c
P R
IN
T
E D
F
IL
E
P A
T H
H R A V A R D J O L L Y
/1
/2
:5 :1
P
M A u to d e s k D o c s /C ity S a ra s o ta
.0
C ity H a ll
R e s tr o o m
R e n o
/A R
-0
C it y H a ll_
R e s tr o o m
R e n o v a ti o n
.r v t
24136
A-101
02/06/25
FAB
S
T S
T
S A
R A
S O
T A
F
L
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
FIRST FLOOR PLANS
AND INTERIOR ELEV
C
IT
Y O
F S
A R
A S
O T
A C
IT
Y
H A
L L
R E
S T
R O
O M
R E
N O
V A
T
IO
N
1/4" = 1'-0"
1 FIRST FLOOR PLAN
1/4" = 1'-0"
3 RM 101 - INT. ELEVATION A
1/4" = 1'-0"
4 RM 101 - INT. ELEVATION B
1/4" = 1'-0"
6 RM 102 - INT. ELEVATION A
1/4" = 1'-0"
7 RM 102 - INT. ELEVATION B
1/4" = 1'-0"
2 FIRST FLOOR RCP
1/4" = 1'-0"
5 RM 103 - INT. ELEVATION A
1/4" = 1'-0"
8 RM 104 - INT. ELEVATION A
FINISH SCHEDULE
ROOM
NO. ROOM NAME
FLOOR WALLS CEILING
REMARKSFINISH BASE NORTH EAST SOUTH WEST FINISH
Level 1
101 MALE PUBLIC RESTROOM PT1 PT CT CT CT EP1 2, 3
102 FEMALE PUBLIC RESTROOM PT1 PT CT EP1 CT CT 2, 3
103 MALE STAFF RESTROOM PT1 PT CT CT CT EP1 2, 3
104 FEMALE STAFF RESTROOM PT1 PT CT/EP1 EP1 CT CT/EP1 2, 3
Level 2
201 FEMALE STAFF/PUBLIC RESTROOM PT1 PT CT CT CT EP1 2, 3
202 MALE STAFF/PUBLIC RESTROOM PT1 PT CT EP1 CT/EP1 CT 2, 3
Revisions
No. Date Revision
Description
1/4" = 1'-0"
9 FIRST FLOOR PLAN - ACC.
CT1/2/3
CT1/2/3
SS1
CT1/2/3
CT1/2/3
SS1
A-102 4
A-1026
FEMALE
STAFF/PUBLIC
RESTROOM
MALE
STAFF/PUBLIC
RESTROOM
9' - 2" 9' - 2"
6' - 1" 6" 2' - 7"
/4
/4
S6A S4A
S6A
3' - 0"
1 13
W1
S1B S1B
S1B
S1B
S1B
S1B4' - 6"
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
EQ 4' - 0" EQ 2' - 5" 4' - 0" 2' - 7"
9' - 0" 9' - 0"
8'-4"
GWB
8'-10"
ACT1
8'-4"
GWB
8'-10"
ACT1
PLAN NOTES: NUMBERED ITEMS NN
1. EXISTING DOOR TO BE REUSED
2. EXISTING TELECOM SYSTEM TO BE REATTACHED ON THIS WALL
3. FILL EXISTING WALL PENETRATION
4. NEW DRINKING FOUNTAIN AND WATER REFILLING STATION
5. NEW JANITOR MOP SINK
1. FIRE RESISTANCE - MAINTAIN INTEGRITY OF EXISTING FIRE
AND/OR SMOKE PARTITIONS THROUGHOUT, UNLESS
NOTED OTHERWISE. MAINTAIN INTEGRITY OF ALL EXISTING
FIREPROOFING, FIRESTOPPING, COLUMN ENCLOSURES,
ETC. TO ENSURE FIRE RESISTANCE MEETS OR EXCEEDS
THAT ORIGINALLY REQUIRED OR SPECIFIED. PATCH ALL
AREAS DAMAGED OR REMOVED DUE TO NEW
CONSTRUCTION TO MATCH THAT OF THE EXISTING OR AS
REQUIRED FOR NEW.
2. FINISHES - ALL EXISTING FINISHES SHALL REMAIN, UNLESS
SCHEDULED FOR NEW. CONTINUE EXISTING FINISHES TO
REMAIN INTO NEW EXTENDED AREAS THAT ARE ADJACENT.
PATCH & REPAIR EXISTING TO MATCH NEW. PREPARE
SUBSTRATES TO RECEIVE NEW FINISHES WHERE
SCHEDULED. FINISH ALL PATCHED OR EXTENDED WALLS
TO NEAREST CHANGE OF DIRECTION, WALL TERMINATION,
OR INTERSECTION PHASING - COORDINATE EQUIPMENT
DELIVERIES AND INSTALLATION WITH THE PHASING PLAN
FOR APPROPRIATE SCHEDULING.
3. CONFLICTS - ANY CONFLICT FOUND WITH EXISTING
CONDITIONS AND REQUIREMENTS FOR NEW
CONSTRUCTION SHALL BE IMMEDIATELY BROUGHT TO THE
ATTENTION OF THE ARCHITECT. IF THE CONFLICT AFFECTS
THE PROGRESS OF THE WORK, VERIFY WITH ARCHITECT
SOLUTION NECESSARY PRIOR TO PROCEEDING WITH THAT
PORTION OF THE WORK AND IN A TIMELY FASHION SO AS
NOT TO DELAY THE WORK. COORDINATE ALL TRADES TO
ASCERTAIN NO FURTHER WORK WILL BE IMPACTED BY THE
CONFLICT, OR ITS SOLUTION.
4. REFER TO FINISH SCHEDULE LEGEND FOR ALL WALL
PROTECTION TYPE DEFINITIONS.
FLOOR PLAN NOTES:
1. STC RATINGS INDICATED ARE SOURCED FROM THE LATEST
EDITION OF THE GYPSUM ASSOCIATION (GA-600) SOUND
CONTROL MANUAL.
2. U.L DESIGN NO.’S INDICATED ARE SOURCED FROM THE
LATEST EDITION OF THE UNDERWRITERS LABORATORIES
INC. (FIRE RESISTANCE) DIRECTORY.
3. ALL PARTITIONS ARE TYPE __________ U.N.O.
4. ALL GYPSUM BOARD SHALL BE TYPE X U.N.O.
5. STAGGER ELECTRICAL BOXES AND OTHER DEVICES IN
ACOUSTICAL PARTITIONS 16” MINIMUM.
6. DEVICES AND EQUIPMENT INSTALLED IN FIRE RATED
PARTITIONS SHALL NOT COMPROMISE THE FIRE
RESISTANCE INTEGRITY OF THE PARTITION.
7. ANY PARTITION REQUIRED TO HAVE PROTECTED OPENINGS
OR PENETRATIONS SHALL BE EFFECTIVELY AND
PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING IN
THE CONCEALED SPACE IN ACCORDANCE WITH FBC (6TH
Ed.) 703.7.
8. PROVIDE METAL SUPPORT IN PARTITIONS TO RECEIVE
WALL MOUNTED EQUIPMENT, CABINETS, HANDRAILS,
ACCESSORIES, ETC.
NUMBER INDICATES PARTITION CORE NOMINAL THICKNESS
LETTER INDICATES PARTITION MODIFIER
M8A
PARTITION TAGS:
LETTER INDICATES PARTITION CORE MATERIAL
PARTITION TYPES GENERAL NOTES:
DIFFUSER GRILLE (REFER TO MECH. DRAWINGS).
EXHAUST GRILLE (REFER TO MECH. DRAWINGS).
GYPSUM WALL BOARD CEILING SYSTEM
RECESS DOWNLIGHT. SEE LIGHTING SPEC.
F/A SMOKE DETECTOR (REFER TO
ELECTRICAL DRAWINGS).
F/A HEAT DETECTOR (REFER TO
ELECTRICAL DRAWINGS).
RETURN AIR GRILLE (REFER TO MECH. DRAWINGS).
INDICATES CEILING HEIGHT AFF IN FEET AND INCHES
& INDICATES CEILING TYPE
REFLECTED CEILING LEGEND
88'-8-1/2"
Type Name
1. REFER ALSO TO MECHANICAL ELECTRICAL DRAWINGS
FOR ADDITIONAL CRITERIA ON ABOVE SYSTEMS AS
APPLICABLE
2. CENTER SYSTEMS IN CEILINGS ADJACENT TO DOORS
ON CENTER OF DOORS OR CENTER OF NEAREST LAY-IN
CEILING TILES
3. IT IS THE INTENT OF THE CEILING DESIGN TO HAVE
VISIBLE DEVICES ALIGNED IN FINISHED AREAS TO THE
GREATEST EXTENT POSSIBLE U.O.N. AND TO BE
CENTERED ON CENTER OF LAY-IN CEILING SYSTEMS
U.O.N.
4. CEILING HEIGHTS - SHALL BE AS NOTED ON PLAN.
WHERE ABUTTING EXISTING CEILINGS, HEIGHT SHALL
MATCH EXISTING AT ADJACENT LOCATIONS, U.O.N.
5. GRILLES, DIFFUSERS, REGISTERS - COORDINATE
REFLECTED CEILING PLANS AND MECHANICAL PLANS.
CONFLICTS SHALL BE RESOLVED PRIOR TO
INSTALLATION.
6. FOR FIXTURES - COORDINATE REFLECTED CEILING
PLAN AND ELECTRICAL LIGHTING PLAN. CONFLICTS
SHALL BE RESOLVED PRIOR TO INSTALLATION.
7. SUPPORT - DO NOT HANG SYSTEMS FROM EXISTING OR
NEW METAL DECKING. CONNECT OR SUSPEND ONLY
FROM STRUCTURAL MEMBERS OR MEMBERS THAT ARE
SECURED TO THE STRUCTURE.
8. ACOUSTICAL TILE SUPPORT - WHENEVER ITEMS SUCH
AS SMOKE DETECTORS, SIGNAGE, SPEAKERS, ETC.
ARE ATTACHED TO CEILING TILES, PROVIDE CROSS
BRACE SUPPORT SECURED TO EACH SIDE OF ITEM.
BRACE SHALL BE LOCATED TO PROVIDE FULL SUPPORT
OF ITEM INDEPENDENTLY OF TILE WITHOUT ANY SAG,
BOW OR TWIST OF CEILING OR GRID.
9. EXISTING CEILING COORDINATION: AT AREAS WITH
EXISTING CEILINGS EXTENDED INTO NEW AREAS
WHERE REQUIRED BY NEW CONSTRUCTION, ATTEMPT
TO MATCH EXISTING CONSTRUCTION, TYPE, COLOR
AND SPACING OF GRID, ETC. TAKE CARE NOT TO
DAMAGE EXISTING CEILINGS TO BE REUSED OR
EXTENDED. REPAIR OR REPLACE AREAS DAMAGED BY
CONSTRUCTION ACTIVITIES AT NO ADDITIONAL COST
TO THE OWNER.
10. THE EXTENT OF THE CEILING WORK IS INTENDED TO BE
ALL INCLUSIVE. REFER ALSO TO MECHANICAL AND
ELECTRICAL DRAWINGS.
S
H
NOTES
ACOUSTIC CEILING PANEL
DESCRIPTION
ITEM
BY
CFCI
CFCI
CFCI
CFCI
CFCI
CFCI
36" REAR GRAB BAR
MIRROR (WIDTH TO BE THE SPACE ON THE WALL)
RECESSED PAPER TOWEL DISPENSER
SOAP DISPENSER
SANITARY NAPKIN DISPOSAL WITH TOILET PAPER
DISPENSER COMBO
TOILET PAPER DISPENSER
NOTES:
1. CONTRACTOR TO FURNISH AND INSTALL CONCEALED WOOD BLOCKING
(WITHIN WALLS) AS REQUIRED TO FIRMLY SECURE WALL-MOUNTED
EQUIPMENT AND/OR ACCESSORIES. ALL WOOD BLOCKING IN CONTACT WITH
MASONRY IS TO BE PRESSURE TREATED.
CFCI: CONTRACTOR FURNISH AND INSTALL
OFCI: OWNER FURNISH AND CONTRACTOR INSTALL
OFOI: OWNER FURNISH AND OWNER INSTALL
2. ALL EXPOSED PIPING AT LAVATORIES SHALL BE INSULATED WITH HANDI
LAV-GUARD OR APPROVED EQUAL, WHITE.
3. ALL TOILET PARTITION DOORS TO HAVE ROBE HOOKS.
GB-1
MIR
PTD
SD
SND
TPH
ACCESSORIES LEGEND
XX-N
CFCI42" SIDE GRAB BARGB-2
CFCI
CFCI
BABY CHANGING TABLE KOALA KARE #KB200
RECESSED TRASH BIN
BCT
TRB
CFCITOILET SEAT COVER DISPENSERTSC
1. EXTERIOR MASONRY DIMENSIONS ARE FROM
FACE OF MASONRY UNIT TO FACE OF MASONRY
UNIT.
2. MASONRY OPENING DIMENSIONS ARE FROM FACE
OF MASONRY UNIT TO FACE OF MASONRY UNIT.
3. INTERIOR DIMENSIONS ARE FROM FACE OF FINISH
TO FACE OF FINISH.
4. LOCATE OPENINGS IN STUD PARTITIONS 6” FROM
ADJACENT PARTITIONS. U.N.O.
5. LOCATE OPENINGS IN INTERIOR MASONRY
PARTITIONS 8” FROM ADJACENT MASONRY
INTERIOR PARTITIONS. U.N.O.
ABBREVIATION CONVENTIONS:
M.O. = MASONRY OPENING
R.O. = ROUGH OPENING
CLEAR = CLEAR OPENING
V.I.F. = VERIFY IN FIELD
=/- = PLUS/MINUS
C.L. = CENTER LINE
ALIGN = LINE UP
TYP. = TYPICAL
CONT. = CONTINUOUS
MIN. = MINIMUM
P.O.B. = POINT OF BEGINNING
DIMENSIONING CONVENTIONS:
NEW CMU WALLS.
FURRING/FACING CONDITIONS MAY
VARY BY TYPE
NEW STUD WALLS. FACING
CONDITIONS MAY VARY BY TYPE
CONC WALLS
EXISTING WALLS.
WALLS LEGEND
FEMALE
STAFF/PUBLIC
RESTROOM
MALE
STAFF/PUBLIC
RESTROOM
SD
PTD
GB-2
SND
GB-1
SND
PTD
SD PTD
SD
PTD
GB-2
TPH
SD
GB-1
MIR MIR
TRB
TRB
SND
TSC
TSC
TSC
1. COLORS AND PATTERNS SHALL BE AS SELECTED BY THE
ARCHTIECT OR INTERIOR DESIGNER
2. SEE TOILET ROOM ELEVATIONS FOR PAINT, CERAMIC TILE (CT)
WALL AND PORCELAIN TILE (PT) FLOOR PATTERN LAYOUTS.
3. TILE EDGES TO RECEIVE METAL EDGE BAND.
FINISH SCHEDULE REMARKS
FLOORING
A. EXISTING TO REMAIN - X
B. PORCELAIN TILE
1. PT1 MANUFACTURER: TBD
PRODUCT: TBD
COLOR: TBD
SIZE: TBD
PATTERN: TBD
INSTALLATION: TBD
BASE
A. EXISTING TO REMAIN - X
B. PORCELAIN TILE
1. PT1 MANUFACTURER: TBD
PRODUCT: TBD
COLOR: TBD
SIZE: TBD
WALLS
A. EXISTING TO REMAIN - X
B. CERAMIC TILE
1. CT1 MANUFACTURER: DALTILE
SERIES: COLOR WHEEL LINEAR
COLOR : BISCUIT 0091
SIZE: 4" X 16"
1. CT1 MANUFACTURER: DALTILE
SERIES: COLOR WHEEL LINEAR
COLOR : DESERT GRAY X114
SIZE: 4" X 16"
1. CT1 MANUFACTURER: DALTILE
SERIES: COLOR WHEEL LINEAR
COLOR : URBAN PUTTY DT 0161
SIZE: 4" X 16"
C. EPOXY PAINT
1. EP MANUFACTURER: TBD
PRODUCT: TBD
COLOR : TBD
SIZE: TBD
CEILINGS
A. ACOUSTICAL CEILING TILE SYSTEM
1. ACT1 MANUFACTURER: ARMSTRONG
PRODUCT: ACOUSTIC CEILING PANEL
SERIES: CASTWORKS METAPHOR
DESIGN: TIDAL WITH FLAT AREA
COLOR: WHITE (WH)
SIZE: 24" X 24"
MISCELLANEOUS:
A. QUARTZ SOLID SURFACE
1. SS1 MANUFACTURER: FORMICA
PATTERN: WHITE RENEW 748
LOCATION: BREAK ROOM/ RESTROOM
COUNTERTOP
B. TOILET PARTITION
1. TP MANUFACTURER: SCRANTON PRODUCTS
COLOR: CONCRETE
TEXTURE: ORANGE PEEL
FINISH MATERIAL LEGEND
1/4" = 1'-0"
1 SECOND FLOOR PLAN
1/4" = 1'-0"
3 RM 201 - INT. ELEVATION A
1/4" = 1'-0"
4 RM 201 - INT. ELEVATION B
1/4" = 1'-0"
5 RM 202 - INT. ELEVATION A
1/4" = 1'-0"
6 RM 202 - INT. ELEVATION B
1/4" = 1'-0"
2 SECOND FLOOR RCP
C
A T
T L E
R
ID
G E
D R
S
T E
S
A R
A S
O T
A F
L
.9
.7
© 2023 HARVARD JOLLY, INC.
Comm. No:
Date:
Drawn:
TO THE BEST OF MY KNOWLEDGE, THE PLANS
AND SPECIFICATIONS COMPLY WITH THE
MINIMUM BUILDING CODES.
NAME:, LIC. #, DATE:
D
C
B
A
3456 2 1
D
C
B
A
3456 2 1 w w w .H a rv a rd
J o lly
.c
P R
IN
T
E D
F
IL
E
P A
T H
H R A V A R D J O L L Y
/1
/2
:5 :1
P
M A u to d e s k D o c s /C ity S a ra s o ta
.0
C ity H a ll
R e s tr o o m
R e n o
/A R
-0
C it y H a ll_
R e s tr o o m
R e n o v a ti o n
.r v t
24136
A-102
02/06/25
FAB
S
T S
T
S A
R A
S O
T A
F
L
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
SECOND FLOOR
PLANS AND
INTERIOR ELEV
C
IT
Y O
F S
A R
A S
O T
A C
IT
Y
H A
L L
R E
S T
R O
O M
R E
N O
V A
T
IO
N
FINISH SCHEDULE
ROOM
NO. ROOM NAME
FLOOR WALLS CEILING
REMARKSFINISH BASE NORTH EAST SOUTH WEST FINISH
Level 1
101 MALE PUBLIC RESTROOM PT1 PT CT CT CT EP1 2, 3
102 FEMALE PUBLIC RESTROOM PT1 PT CT EP1 CT CT 2, 3
103 MALE STAFF RESTROOM PT1 PT CT CT CT EP1 2, 3
104 FEMALE STAFF RESTROOM PT1 PT CT/EP1 EP1 CT CT/EP1 2, 3
Level 2
201 FEMALE STAFF/PUBLIC RESTROOM PT1 PT CT CT CT EP1 2, 3
202 MALE STAFF/PUBLIC RESTROOM PT1 PT CT EP1 CT/EP1 CT 2, 3
Revisions
No. Date Revision
Description
1/4" = 1'-0"
7 SECOND FLOOR PLAN - ACC.
SEE --- SYMBOLS ON PLANS
1. ACCESSIBLE CLEARANCES AND MOUNTING HEIGHTS INDICATED IN
ACCORDANCE WITH 2023 FLORIDA ACCESSIBILITY CODE FOR
BUILDING CONSTRUCTION, ADOPTED PURSUANT TO SECTION
553.503 FLORIDA STATUTES, BASED ON THE 2010 ADA STANDARDS
FOR ACCESSIBLE DESIGN.
2. ALL DIMENSIONS INDICATED ARE FROM FACE OF FINISHES.
3. WATER CLOSETS, URINALS, LAVATORIES, AND SINKS SHALL BE
INSTALLED A MINIMUM OF 15" FROM THE CENTERLINE OF THE
FIXTURE TO ANY SIDE WALL, PARTITION, VANITY OR OTHER
OBSTRUCTION (FBC PLUMBING 405.3.1).
4. ACCESSIBLE WATER CLOSETS SHALL BE INSTALLED A MINIMUM OF
16" AND A MAXIMUM OF 18" FROM THE CENTERLINE OF THE FIXTURE
TO ANY SIDE WALL, PARTITION, VANITY OR OTHER OBSTRUCTION.
5. TOILET FLUSH VALVE CONTROLS SHALL BE LOCATED ON THE OPEN
SIDE OF THE WATER CLOSET AND ROUGH-IN SHALL BE
COORDINATED WITH THE REAR GRAB BAR HEIGHT TO PROVIDE A
MINIMUM CLEAR DIMENSION OF 1-1/2" BELOW THE GRAB BAR.
6. PROVIDE OFFSET OR ADJUSTABLE TRAPS FOR ACCESSIBLE
LAVATORIES AND SINKS INSTALLED IN COUNTERTOPS WITH BASE
CABINETS TO ALLOW FOR KNEE AND TOE CLEARANCES FOR A
FORWARD APPROACH.
7. EQUIPMENT INSTALLED BELOW ACCESSIBLE LAVATORIES, SUCH AS
FAUCET SENSOR CONTROL MODULES AND INSTANT HOT WATER
HEATERS SHALL NOT PROJECT INTO THE REQUIRED KNEE AND TOE
CLEARANCES REQUIRED FOR A FORWARD APPROACH.
8. COORDINATE INSTALLATION OF SINKS, PLUMBING AND ELECTRICAL
ITEMS IN AND ADJACENT TO CASEWORK.
9. TOILET ACCESSORIES SHALL NOT PROTRUDE INTO THE CLEAR
FLOOR SPACE AT A LAVATORY OR SINK OUTSIDE THE DESIGNATED
KNEE AND TOE SPACE. ACCESSORIES SHALL NOT PROTRUDE MORE
THAN 4" THE CLEAR FLOOR SPACE AT A LAVATORY OR SINK, INTO A
PATH OF TRAVEL OR A REQUIRED TURNING SPACE.
10. TYPICAL TOILET ROOM PLANS AND ELEVATIONS ON THIS SHEET
INDICATE MINIMUM CLEARANCES AND ACCESSORY MOUNTING
HEIGHTS. REFER TO FLOOR PLANS, ENLARGED FLOOR PLANS AND
INTERIOR ELEVATIONS FOR TOILET ROOM CONFIGURATIONS.
A. FBC ACCESSIBILITY 604.1 EXCEPTION: EDUCATIONAL
FACILITIES MAY UTILIZE ADVISORY 604.9 "WATER CLOSETS
AND TOILET COMPARTMENTS FOR CHILDREN'S USE". REFER
TO FLOOR PLANS, ENLARGED FLOOR PLANS AND INTERIOR
ELEVATIONS FOR TOILET ROOM CONFIGURATIONS AND
MOUNTING HEIGHT REQUIREMENTS THAT MAY VARY FROM
THOSE SHOWN ON THIS SHEET WHEN ADVISORY 604.9
SPECIFICATIONS ARE USED.
11. SPECIFICATIONS AND SIZES OF ACCESSORIES ARE BASED ON
BOBRICK WASHROOM EQUIPMENT (U.N.O.). REFER TO
SPECIFICATION SECTION 102800 FOR TOILET ACCESSORIES AND
102800S FOR ACCESSORY SCHEDULE.
12. OWNER PROVIDED ACCESSORIES SHALL BE COORDINATED WITH
THE ARCHITECT PRIOR TO INSTALLATION FOR REQUIRED MOUNTING
HEIGHTS, CLEARANCES AND REACH RANGES.
13. ALL EQUIPMENT SHOWN SHALL BE STAINLESS STEEL, SATIN FINISH
(U.N.O.).
14. ALL EXPOSED PIPING UNDER LAVATORIES SHALL BE INSULATED
WITH PIPE AND VALVE COVERINGS TO PROTECT AGAINST CONTACT.
REFER TO SPECIFICATION SECTION 102800 FOR LAVATORY PIPE
GUARD PRODUCT INFORMATION.
TOILET ROOM & ACCESSORY NOTES
TOILET ACCESSORY LEGENDS
FINISH FLOOR
M
IN
TO BOTTOM
OF THE
REFLECTING
SURFACE
FRAMED MIRROR FRAMELESS MIRROR
M
IN
TO BOTTOM
OF THE
REFLECTING
SURFACE
REFER TO ACCESSORY
SCHEDULE AND/OR
INTERIOR ELEVATIONS
FOR HEIGHTS
WIDTH TO MATCH WIDTH
OF COUNTERTOP
ref: 603.3
SOAP
DISPENSERS
T O
S P
O U
T
PAPER
TOWEL
DISPENSERS
T O
S P
O U
T
TO TOP OF BIN
WASTE
RECEPTACLE
T O
S L O
T
T O
S L O
T
T O
T O
P
T O
T O
P
M A
X
MULTI-PURPOSE
UNITS
SEAT COVER
DISPENSER
TOILET TISSUE DISPENSERS
CL CL CL
CL CL CL CL CL
m in
30" min 18" max
16" min
TOILET AND SHOWER ACCESSORY MOUNTING HEIGHTS ref: 308.2.1 through 308.3.2 and 309
ACCESSIBLE DRINKING FOUNTAIN
CLEARANCES & MOUNTING HEIGHTS
min
15" m in m in m in min
15"
30" min
18" max
16" min 18" m in
60" min min
18" 36" m in
L A
T C
H S
ID
E
P P
R O
A C
H m in
8" min m a x m in
11" min 6" max m in
/2 m in m in
/2 m in
/2 m in to s lo t m a x
TO RIM OF LAV. OR
COUNTERTOP
WHICHEVER IS HIGHER
(a) projecting objects
(b) recessed objects
MANEUVERING
CLEARANCE FOR
FORWARD
APPROACH
Clearances at Water Closet and Lavatory ref: 306.2, 306.3, 604.3.1 and 604.3.2
Wheelchair Accessible Toilet Compartment ref: 604.8.1.6
Ambulatory Accessible Toilet Compartment ref: 604.8.2
Knee and Toe Clearance at Lavatory ref: 306.2 and 306.3
Spacing and Clearances at Grab Bars ref: 609.3
Clearances and Accessory Locations at Lavatory ref: 306.2, 306.3, 308.2.1 - 308.3.2, 309, 606.2 and 609.4
CL CL
TO BOTTOM
OF THE
REFLECTING
SURFACE
AT MIRROR
min
24" min
12"
36" min 6" max
KNEE AND TOE CLEARANCES
PER FBC ACCESSIBILITY 606.2
to r im o f la v m a x transfer side
CL GRAB BAR
Height and Depth of Urinals ref: 605.2(a)
36" pref.
30" min
6" min from rim
30" x 48" CLEAR FLOOR SPACE
URINAL SCREEN SIZE AND
LOCATION DIMENSIONS PER
FBC PLUMBING 405.3.5
m in m a x m a x min
13 1/2"
NOTE: NON-ADA
URINALS TO BE
INSTALLED WITH
RIM OF FIXTURE AT
24" A.F.F.
FINISH FLOOR
BOTTOM OF SCREEN
Drinking Fountain Spout Location ref: 307.4, 602.5, and 602.7
60" min
TOP OF SCREEN
ACCESSORIES NOTES:
1. THE WATER CLOSET, ASSOCIATED GRAB BARS, TOILET
PAPER DISPENSERS, SEAT COVER AND OTHER
DISPENSERS, COAT HOOKS, SHELVES AND SANITARY
NAPKIN DISPOSAL UNITS ARE THE ONLY ELEMENTS THAT
CAN OVERLAP THE REQUIRED WATER CLOSET CLEARANCE
(604.3.2).
2. NO ELEMENT, INCLUDING DISPENSERS, HAND DRYERS,
ETC., CAN OVERLAP THE CLEAR FLOOR SPACE AT THE
LAVATORY OUTSIDE THE DESIGNATED KNEE AND TOE
SPACE (606.2).
ACCESSORIES
LOCATED OUTSIDE
THE DESIGNATED
KNEE AND TOE SPACE
MUST BE RECESSED
HIGH LOW W/
BOTTLE
FILLER
30" x 48" CLEAR
FLOOR SPACE AT
ACCESSIBLE
FOUNTAIN
PROVIDE CANE SHROUD AT HIGH UNIT WHEN
DRINKING FOUNTAIN IS NOT LOCATED IN AN
ALCOVE AND THE BOTTOM OF THE HIGH UNIT
EXCEEDS 27" A.F.F.
FINISH FLOOR
to s p o u t m in to s p o u t m a x to m in
6" max.11" min.
8" min.
to s p o u t o u tl e t m a x
17" to 25" to s p o u t o u tl e t m in a n d m a x m a x
CL
Grab Bar and Dispenser Outlet Location at Water Closets ref: 308.2.1 - 308.3.2, 309, 604.4, 604.5.1, 604.5.2, and 604.7
1 1/2" MIN. CLEAR
BETWEEN GRAB BAR
AND FLUSH VALVE
TOP OF SEAT
m a x m in
54" min
12" max 42" min m a x
FINISH FLOOR
m in
7"-9"
AREA OF DISPENSER
OUTLET LOCATION
NOTE: FOR
SURFACE MOUNTED
DISPENSERS
LOCATED ABOVE
GRAB BAR, REFER
TO FIGURE 609.3
CL
ref: 603.4
GRAB BARS
T O
T O
P
CHILDCARE UNITS
ACT
CEILING
7' - 2"
8' - 10"
EXISTING
WD PANEL
5/8" GYP BOARD OVER 1
5/8" METAL FRAMING AT
16" O.C. REFER TO RCP
FOR HEIGHT AND FINISH
E X
T
W A
ACT PANEL
8' - 4"
8' - 10"
DESCRIPTION
ITEM
BY
CFCI
CFCI
CFCI
CFCI
CFCI
CFCI
36" REAR GRAB BAR
MIRROR (WIDTH TO BE THE SPACE ON THE WALL)
RECESSED PAPER TOWEL DISPENSER
SOAP DISPENSER
SANITARY NAPKIN DISPOSAL WITH TOILET PAPER
DISPENSER COMBO
TOILET PAPER DISPENSER
NOTES:
1. CONTRACTOR TO FURNISH AND INSTALL CONCEALED WOOD BLOCKING
(WITHIN WALLS) AS REQUIRED TO FIRMLY SECURE WALL-MOUNTED
EQUIPMENT AND/OR ACCESSORIES. ALL WOOD BLOCKING IN CONTACT WITH
MASONRY IS TO BE PRESSURE TREATED.
CFCI: CONTRACTOR FURNISH AND INSTALL
OFCI: OWNER FURNISH AND CONTRACTOR INSTALL
OFOI: OWNER FURNISH AND OWNER INSTALL
2. ALL EXPOSED PIPING AT LAVATORIES SHALL BE INSULATED WITH HANDI
LAV-GUARD OR APPROVED EQUAL, WHITE.
3. ALL TOILET PARTITION DOORS TO HAVE ROBE HOOKS.
GB-1
MIR
PTD
SD
SND
TPH
ACCESSORIES LEGEND
XX-N
CFCI42" SIDE GRAB BARGB-2
CFCI
CFCI
BABY CHANGING TABLE KOALA KARE #KB200
RECESSED TRASH BIN
BCT
TRB
CFCITOILET SEAT COVER DISPENSERTSC
C
A T
T L E
R
ID
G E
D R
S
T E
S
A R
A S
O T
A F
L
.9
.7
© 2023 HARVARD JOLLY, INC.
Comm. No:
Date:
Drawn:
TO THE BEST OF MY KNOWLEDGE, THE PLANS
AND SPECIFICATIONS COMPLY WITH THE
MINIMUM BUILDING CODES.
NAME:, LIC. #, DATE:
D
C
B
A
3456 2 1
D
C
B
A
3456 2 1 w w w .H a rv a rd
J o lly
.c
P R
IN
T
E D
F
IL
E
P A
T H
H R A V A R D J O L L Y
/1
/2
:5 :1
P
M A u to d e s k D o c s /C ity S a ra s o ta
.0
C ity H a ll
R e s tr o o m
R e n o
/A R
-0
C it y H a ll_
R e s tr o o m
R e n o v a ti o n
.r v t
24136
A-410
02/06/25
FAB
S
T S
T
S A
R A
S O
T A
F
L
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
TYPICAL TOILET &
SHOWER ROOM
DETAILS
C
IT
Y O
F S
A R
A S
O T
A C
IT
Y
H A
L L
R E
S T
R O
O M
R E
N O
V A
T
IO
N
1 1/2" = 1'-0"
2 CEILING DETAIL 2
1 1/2" = 1'-0"
1 CEILING DETAIL 1
Revisions
No. Date Revision
Description