25-0077 MARSOC Ceremonial Bell Tower - SOW.pdf

PDF 5 MB Posted

Attached to
MARSOC Ceremonial Bell Tower
Solicitation number
N40085-25-R-9022
Issued by

About this file

These documents are design drawings for a Ceremonial Bell Tower project at Marine Corps Base Camp Lejeune in North Carolina. The project, commissioned by Naval Facilities Engineering Systems Command (NAVFAC) Mid-Atlantic, involves constructing a bell tower and three parking monuments with architectural, structural, and electrical specifications. The bell tower will feature face brick walls, a standing seam metal roof, a bronze bell, and 4" galvanized steel tube posts, with a total height of approximately 7'-9". The parking monuments will have similar architectural elements, including precast concrete caps and face brick. The electrical design includes recessed LED downlighting with a photocell-controlled exterior lighting circuit. The project is dated for completion in August 2025, with design drawings prepared by MBF Architects and multiple engineering consultants, including structural engineering by NRW Structural Engineers and electrical design by PACE Collaborative.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

D E S

IG

N A

N D

C O

N S T R

U C T

IO

N

D C

C O

R E

N A V A L S

T A T

IO

N

N O

R F O

L K V A

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

J E

U N

E

N C

F ile

P ri n t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

T

T C

E

TI

HCRAD

R E

G I S

ERE

A N

I

L

ORA

N O

R

T H

C

N

D A

R

N

DE

.J UE

ER

III

C

N

NRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

L A

N T

IC

AS INDICATED

M

A

P.

STCETIHCRA

FB

BERN N.C

.NEW

CERT. NO.

UTCETIHCRA

DERET

SI

G E R

N

OI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

BELL

TOWER

BT

S p ro je c ts

\2

\2

C

L M

A R

S O

C P

-1

M a n e u v e r

F a c ili ty S u b t o

N R

W \2

D e s ig n \2

D w g s \2

B

T A

R C

H

.r v t

/6

/2

:5

:5

P

M

T

IT

L E

S H

E E

T

G-001

1754108

C E

R E

M O

N

IA

L B

E L

L T

O W

E R

12932701

REL REL DJE,III

J. EMORY / J. BACE

07 AUG 2025

MCB CAMP LEJEUNE

NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND

MID-ATLANTIC

DESIGN AND CONSTRUCTION

FACILITIES ENGINEERING AND ACQUISITION DIVISION

NORFOLK, VIRGINIA

PROJECT NO. 25-0077

CEREMONIAL BELL TOWER

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

R

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

D E S

IG

N A

N D

C O

N S T R

U C T

IO

N

D C

C O

R E

N A V A L S

T A T

IO

N

N O

R F O

L K V A

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

J E

U N

E

N C n t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

T

T C

E

TI

HCRAD

R E

G I S

ERE

A N

I

L

ORA

N O

R

T H

C

N

D A

R

N

DE

.J UE

ER

III

C

N

NRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

L A

N T

IC

AS INDICATED

M

A

P.

STCETIHCRA

FB

BERN N.C

.NEW

CERT. NO.

UTCETIHCRA

DERET

SI

G E R

N

OI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

BELL

TOWER

BT

S p ro je c ts

\2

\2

C

L M

A R

S O

C P

-1

M a n e u v e r

F a c ili ty S u b t o

N R

W \2

D e s ig n \2

D w g s \2

B

T A

R C

H

.r v t

/6

/2

:5

:5

P

M

L O

C A

T

IO

N M

A P

S N

O T

E S

A N

D I N

D E

X O

F D

R A

W

IN

G S

G-002

1754108

C E

R E

M O

N

IA

L B

E L

L T

O W

E R

12932702

REL REL DJE,III

J. EMORY / J. BACE

07 AUG 2025

ARCHITECTURE

MBF ARCHITECTS, P.A.

317-C POLLOCK STREET

NEW BERN, NC 28560

CIVIL

AVOLIS ENGINEERING, P.A.

5405 MORTON ROAD

NEW BERN, NC 28562

LANDSCAPE ARCHITECTURE

MIHALY LAND DESIGN

330 MILITARY CUTOFF ROAD, SUITE A-3

WILMINGTON, NC 28405

GEOTECHNICAL

CAPE FEAR ENGINEERING, INC.

51 POOLE ROAD

LELAND, NC 28451

LIFE SAFETY

PACE COLLABORATIVE

1277 PERIMETER PARKWAY

VIRGINIA BEACH, VA 23455

STRUCTURAL

NRW STRUCTURAL ENGINEERS

748 LORD DUNMORE DRIVE, SUITE 101

VIRGINIA BEACH, VA 23464

COMPREHENSIVE INTERIOR DESIGN

WITHIN INTERIOR DESIGN, INC.

1008 GRANBY STREET

NORFOLK, VA 23510

FIRE PROTECTION

PACE COLLABORATIVE

1277 PERIMETER PARKWAY

VIRGINIA BEACH, VA 23455

PLUMBING / MECHANICAL / ELECTRICAL

PACE COLLABORATIVE

1277 PERIMETER PARKWAY

VIRGINIA BEACH, VA 23455

REGIONAL MAP

VICINITY MAP

SITE MAP

PROJECT LOCATION

N

N

N

TELECOMMUNICATIONS

PACE COLLABORATIVE

1277 PERIMETER PARKWAY

VIRGINIA BEACH, VA 23455

LIGHTNING PROTECTION

PACE COLLABORATIVE

1277 PERIMETER PARKWAY

VIRGINIA BEACH, VA 23455

AUDIOVISUAL

PACE COLLABORATIVE

1277 PERIMETER PARKWAY

VIRGINIA BEACH, VA 23455

DESIGN TEAM

GENERAL PROJECT NOTES GOVERNING REGULATIONS

1. WHERE EXISTING CONSTRUCTION IS DAMAGED BY CONSTRUCTION REQUIRED BY THESE

DOCUMENTS. REPAIR THE DAMAGED ITEM(S) WITH MATERIALS TO MATCH THE ADJACENT

MATERIAL, TEXTURE AND COLOR.

2. FIELD VERIFY EXISTING DIMENSIONS, PRIOR TO ORDERING MATERIALS OR BEGINNING

DEMOLITION.

3. ALL ITEMS NOT SHOWING AS "EXISTING" MUST BE PROVIDED AND INSTALLED UNDER THE

REQUIREMENTS OF THIS CONTRACT.

4. COORDINATE LAY DOWN AREA WITH THE CONTRACTING OFFICER PRIOR TO THE

PRECONSTRUCTION MEETING. THE ALLOWABLE AREA SIZE MUST BE ESTABLISHED BY THE

CONTRACTING OFFICER.

5. MANUFACTURER'S TRADE NAMES LISTED ARE NOT INTENDED TO BE PROPRIETARY.

PRODUCTS OF OTHER MANUFACTURERS WILL BE ACCEPTABLE PROVIDED THEY MATCH THE

COLOR, FINISHES, TEXTURES AND PATTERNS OF THE MANUFACTURER LISTED, AND MEET THE

TECHNICAL REQUIREMENTS OF THE SPECIFICATIONS.

6. OBSERVE AND MAINTAIN BUILDING AND COMPOUND SECURITY REQUIREMENTS AS DIRECTED

BY THE CONTRACTING OFFICER.

7. CONSTRUCTION WILL BE ACCOMPLISHED IN AND AROUND AREAS WHICH WILL REMAIN

OPERATIONAL. AVOID INTERFERENCE WITH THE OPERATIONAL WORK ROUTINE.

8. ALL SUBMITTALS REQUIRED BY THESE DRAWINGS OR SPECIFICATIONS MUST BE SUBMITTED

TO THE CONTRACTING OFFICER FOR APPROVAL TO COMMENCEMENT OF RELATED WORK.

COMMISSIONING

PACE COLLABORATIVE

1277 PERIMETER PARKWAY

VIRGINIA BEACH, VA 23455

CYBERSECURITY

RAVEN WHITE SECURITY, LLC

432 WALNUT AVENUE

CHARLOTTE, NC 28208

SUSTAINABILITY COORDINATOR

MBF ARCHITECTS, P.A.

317-C POLLOCK STREET

NEW BERN, NC 28560

BUILDING CODE:

UNIFIED FACILITIES CRITERIA (UFC) 1-200-01 (01 SEP 2022, W/ CHANGE 3, 26 FEB 2024) UNIFIED FACILITIES CRITERIA (UFC) 1-200-02 (01 DEC. 2020, W/CHANGE 02, 01 JUN 2022) UNIFIED FACILITIES CRITERIA (UFC) 3-110-03 (01 MAY 2012, W/CHANGE 5, 12 JUN 2020)

ACCESSIBILITY CODE:

UNIFORM ACCESSIBILITY STANDARDS (UFAS)

AMERICANS WITH DISABILITIES ACT (ADA)

ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES (ADAAG)

MECHANICAL CODE:

INTERNATIONAL MECHANICAL CODE (IMC) 2021

ELECTRICAL CODE:

NFPA 70, NATIONAL ELECTRIC CODE (2023)

PLUMBING CODE:

INTERNATIONAL PLUMBING CODE (IPC) 2021

FIRE PREVENTION & LIFE SAFETY CODE:

UNIFIED FACILITIES CRITERIA (UFC) 3-600-01 (15 DEC. 2016, W/CHANGE 6, 06 MAY 2021)

NFPA 101, LIFE SAFETY CODE (2024)

INDEX OF DRAWINGS

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

C-001

12932703

C

IV

IL

L

EG

EN

D , A

BB

R

E R

V

IA

TI

O

N S

AN

D

N O

TE

S

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D

EP

A R

TM

EN

T O

F

TH

E N

AV

Y

N

AV

A L

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

Y

ST

E M

S C

O M

M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

D

ES

IG

N

A N

D C

O N

ST

RU

CT

IO

N

D C)

C O

RE

N

AV

AL

S

TA

TI

O

N

N O

RF

O

LK

, V

A

M A

R

IN

E C

O R

PS

B

AS

E

C A

M P

LE

JE

U N

E, N

C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

AN

D

M

ID

AT

LA

N

TI

C

AS INDICATED

OF 16

1754108

C

ER

EM

O

N

IA

L B

E

LL

T O

W E

R

JKA MSP JKA

SY

M

D E

S C

R

IP

TI

O

N D

AT

E

AP

PR

J. EMORY / J. BACE

Fi le

P at h P rin t D at e:

P :\2

_F Y

M

IL

C

O N

P ro je ct

P -1

7, S O

F In fo rm at io n M an eu ve r F ac ilit y (N

R W

)\D W

G \2

B E

LL

T

O W

E R

B A

S E

(8 -7

-2 5)

.d w g A ug us t 0 7,

- 9

:4 5a m

CIVIL ABBREVIATIONS GENERAL CONSTRUCTION NOTES UTILITY NOTESCIVIL LEGEND

DESCRIPTION NEWEXISTING / DEMO

Digitally signed by John K Avolis

C-100

O V

E R

A

LL

S

IT

E P

LA

N

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D

EP

A R

TM

EN

T O

F

TH

E N

AV

Y

N

AV

A L

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

Y

ST

E M

S C

O M

M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

D

ES

IG

N

A N

D C

O N

ST

RU

CT

IO

N

D C)

C O

RE

N

AV

AL

S

TA

TI

O

N

N O

RF

O

LK

, V

A

M A

R

IN

E C

O R

PS

B

AS

E

C A

M P

LE

JE

U N

E, N

C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

AN

D

M

ID

AT

LA

N

TI

C

AS INDICATED

OF 16

1754108

C

ER

EM

O

N

IA

L B

E

LL

T O

W E

R

JKA MSP JKA

SY

M

D E

S C

R

IP

TI

O

N D

AT

E

AP

PR

J. EMORY / J. BACE

Fi le

P at h P rin t D at e:

P :\2

_F Y

M

IL

C

O N

P ro je ct

P -1

7, S O

F In fo rm at io n M an eu ve r F ac ilit y (N

R W

)\D W

G \2

B E

LL

T

O W

E R

B A

S E

(8 -7

-2 5)

.d w g A ug us t 0 7,

- 9

:4 6a m

12932704

CS101

S

IT

E

LA

YO

U

T P

LA

N

SHEET WORK ITEMS

SHEET LEGEND

DESCRIPTION SYMBOL

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D

EP

A R

TM

EN

T O

F

TH

E N

AV

Y

N

AV

A L

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

Y

ST

E M

S C

O M

M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

D

ES

IG

N

A N

D C

O N

ST

RU

CT

IO

N

D C)

C O

RE

N

AV

AL

S

TA

TI

O

N

N O

RF

O

LK

, V

A

M A

R

IN

E C

O R

PS

B

AS

E

C A

M P

LE

JE

U N

E, N

C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

AN

D

M

ID

AT

LA

N

TI

C

AS INDICATED

OF 16

1754108

C

ER

EM

O

N

IA

L B

E

LL

T O

W E

R

JKA MSP JKA

SY

M

D E

S C

R

IP

TI

O

N D

AT

E

AP

PR

J. EMORY / J. BACE

Fi le

P at h P rin t D at e:

P :\2

_F Y

M

IL

C

O N

P ro je ct

P -1

7, S O

F In fo rm at io n M an eu ve r F ac ilit y (N

R W

)\D W

G \2

B E

LL

T

O W

E R

B A

S E

(8 -7

-2 5)

.d w g A ug us t 0 7,

- 9

:4 6a m

12932705

CS501

D

ET

A

IL

S

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D

EP

A R

TM

EN

T O

F

TH

E N

AV

Y

N

AV

A L

FA

C

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

Y

ST

E M

S C

O M

M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

D

ES

IG

N

A N

D C

O N

ST

RU

CT

IO

N

D C)

C O

RE

N

AV

AL

S

TA

TI

O

N

N O

RF

O

LK

, V

A

M A

R

IN

E C

O R

PS

B

AS

E

C A

M P

LE

JE

U N

E, N

C

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

AN

D

M

ID

AT

LA

N

TI

C

AS INDICATED

OF 16

1754108

C

ER

EM

O

N

IA

L B

E

LL

T O

W E

R

JKA MSP JKA

SY

M

D E

S C

R

IP

TI

O

N D

AT

E

AP

PR

J. EMORY / J. BACE

Fi le

P at h P rin t D at e:

P :\2

_F Y

M

IL

C

O N

P ro je ct

P -1

7, S O

F In fo rm at io n M an eu ve r F ac ilit y (N

R W

)\D W

G \2

B E

LL

T

O W

E R

B A

S E

(8 -7

-2 5)

.d w g A ug us t 0 7,

- 9

:4 6a m

12932706

COMPONENTS AND CLADDING ULTIMATE WIND PRESSURES

INTERPOLATE BETWEEN AREAS INDICATED.

CORNER ZONES EQUAL A = 3 FEET.

REFER TO SKETCH BELOW FOR ZONE DEFINITIONS.

AREA

(SF)

A<10

A≥100

ROOF ZONES WALL ZONES

COMPONENTS AND CLADDING WIND PRESSURES

+33.7 -60.5

+18.4 -37.5

+33.7 -83.5

+18.4 -54.1

+45.2 -49.0

+38.4 -42.3

+45.2 -60.5

+38.4 -47.0

3 32e

3 32e

2e 2e

ZONES

1 1

2e & 2r

+33.7

+18.4

2e & 2r

-118.7

-71.6

-72.8 -95.8

-68.9 -81.0

OVERHANG ZONES

2r

2r2r

2r

A A

A

A

-83.5

-54.1

ARCH ARCHITECT, ARCHITECTURAL

CMU CONCRETE MASONRY UNIT

DWG DRAWING

DWGS DRAWINGS

PSI POUNDS PER SQUARE INCH

PSF POUNDS PER SQUARE FOOT

REINF REINFORCE,REINFORCING

STD STANDARD

TYP TYPICAL

VERT VERTICAL

WWF WELDED WIRE FABRIC

OC ON CENTER

STRUCTURAL

ABBREVIATIONS LIST

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

D E S

IG

N A

N D

C O

N S T R

U C T

IO

N

D C

C O

R E

N A V A L S

T A T

IO

N

N O

R F O

L K V A

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

J E

U N

E

N C n t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

L A

N T

IC

AS INDICATED

BELL

TOWER

BT

07 AUG 2025

C L o c a l R e v it F ile s \2

B T

S T

R U

C T js s

D

E .r v t

/7

/2

:1 :2

A

M

G E

N E

R A

L N

O T

E S

S-001

1754108

C E

R E

M O

N

IA

L B

E L

L T

O W

E R

12932707

LWM JSS PDM

GENERAL NOTES:

GENERAL NOTES:

1. ALL WORK MUST COMPLY WITH THE CODES LISTED BELOW AND IN THE SPECIFICATIONS

2. THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE PROVISIONS OF THE

INTERNATIONAL BUILDING CODE, 2021 EDITION, AS MODIFIED BY UFC 1-200-01, DATED 01

SEPTEMBER 2022, CHANGE 3 26 FEBRUARY 2023 AND IN ACCORDANCE WITH UFC 3-301-01

“STRUCTURAL ENGINEERING”, DATED 11 APRIL 2023, CHANGE 1, 2 OCTOBER 2023.

3. VERIFY ALL DRAWINGS FOR COORDINATION BETWEEN TRADES, LOCATE SLOTS, SLEEVES AND TRENCHES AS REQUIRED. PROVIDE AND INSTALL ANCHORS, INSERTS, HANGERS, ETC. AS REQUIRED

FOR VARIOUS TRADES.

4. SPECIAL INSPECTIONS ARE IN ACCORDANCE WITH SPECIFICATION SECTION 01 45 35.

5. SUBMIT SHOP DRAWINGS FOR REVIEW BEFORE PROCEEDING WITH THE WORK. THE CONTRACTOR

MUST CHECK ALL DIMENSIONS AND ACCEPT FULL RESPONSIBILITY FOR DIMENSIONAL

CORRECTNESS.

6. UNDER NO CIRCUMSTANCES CAN THE REPRODUCTION OF CONTRACT DRAWINGS BE USED AS SHOP

DRAWINGS.

7. PROVIDE ALL TEMPORARY GUYING AND BRACING REQUIRED TO ERECT AND HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL ALL STRUCTURAL WORK AND CONNECTIONS HAVE BEEN COMPLETED.

8. IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITION OF JOB SITE INCLUDING SAFETY OF ALL

PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK.

9. THE DUTY OF THE CONTRACTING OFFICER IN CONDUCTING CONSTRUCTION REVIEW OF

CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF ADEQUACY OF

CONTRACTOR'S SAFETY MEASURES IN, ON, OR NEAR THE CONSTRUCTION SITE.

10. TYPICAL DETAILS AND GENERAL NOTES APPLY TO ALL PARTS OF THE JOB EXCEPT WHERE

SPECIFICALLY DETAILED OR NOTED OTHERWISE.

11. STRUCTURAL DRAWINGS SHOW ONLY THE BASIC STRUCTURAL FRAMING. REFER TO

ARCHITECTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR NON-STRUCTURAL

ITEMS WHICH REQUIRE SPECIAL PROVISIONS DURING THE CONSTRUCTION OF THE BELL TOWER.

12. INFORM THE CONTRACTING OFFICER IN WRITING OF ANY DEVIATION FROM THE CONTRACT

DOCUMENTS. THE CONTRACTOR IS NOT RELIEVED OF THE RESPONSIBILITY OF SUCH DEVIATION BY

THE CONTRACTING OFFICER REVIEW OF SHOP DRAWINGS, PRODUCT DATA, ETC. UNLESS THE

CONTRACTOR HAS SPECIFICALLY INFORMED THE CONTRACTING OFFICER OF SUCH DEVIATION AT THE TIME OF SUBMISSION, AND THE CONTRACTING OFFICER HAS GIVEN WRITTEN APPROVAL TO

THE SPECIFIC DEVIATION.

CAST IN PLACE CONCRETE NOTES:

1. CAST IN PLACE CONCRETE MUST COMPLY WITH THE AMERICAN CONCRETE INSTITUTE

(ACI- 318-19), COMMENTARY, (ACI-318R-19), AND THE SPECIFICATIONS FOR STRUCTURAL

CONCRETE (ACI 301).

2. DETAILING OF ALL CONCRETE STEEL REINFORCEMENT MUST BE IN ACCORDANCE WITH

ACI 315R-18 GUIDE TO PRESENTING REINFORCING STEEL DESIGN DETAILS.

3. ALL CONCRETE MUST BE NORMAL WEIGHT, UNLESS OTHERWISE NOTED, CONCRETE

HAVING A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS AS FOLLOWS:

A. FOUNDATIONS 4,000 PSI

B. EXTERIOR SLAB ON GRADE 4,500 PSI

C. CONCRETE NOT OTHERWISE NOTED 3,000 PSI

D. CONCRETE EXPOSED TO WEATHER MUST BE AIR ENTRAINED.

4. ALL REINFORCING MUST BE AS FOLLOWS:

A. REINFORCING BARS - ASTM A-615, GRADE 60

B. WELDED WIRE REINFORCEMENT - ASTM A-1064 FLAT SHEET TYPE, ROLL TYPE NOT

ACCEPTABLE.

C. WELDABLE REINFORCEMENT ASTM A706

5. WELDED WIRE REINFORCEMENT MUST BE PROPERLY SUPPORTED PRIOR TO PLACING

CONCRETE. HOOKING OF FABRIC IS NOT PERMITTED.

6. UNLESS OTHERWISE NOTED, REINFORCING STEEL MARKED CONTINUOUS (CONT.) MUST

BE LAPPED PER THE REINFORCING LAP SCHEDULE.

7. HOLD ALL REINFORCING STEEL SECURELY IN PLACE TO PREVENT DISLOCATION DURING

THE POURING OPERATION. SUPPORT SLAB REINFORCING BARS ON HIGH CHAIRS AND BAR

SPACERS OF SUITABLE DESIGN, OR CONCRETE BLOCKS HAVING THE SAME MINIMUM

COMPRESSIVE STRENGTH OF THE CONCRETE SLAB.

8. DO NOT PLACE CONCRETE UNTIL ALL EMBEDDED WORK HAS BEEN INSTALLED, TESTED

AND INSPECTED.

9. EXCEPT AS OTHERWISE SHOWN MINIMUM PROTECTION (CONCRETE COVER) FOR

REINFORCING STEEL MUST BE AS FOLLOWS:

CONCRETE SURFACES CAST AGAINST SOIL: 3"

CONCRETE SURFACES EXPOSED TO EARTH OR WEATHER: 2”

INTERIOR CONCRETE SURFACES: 1-1/2” FOR SLABS

FOUNDATION NOTES:

1. FOUNDATIONS FOR THIS STRUCTURE HAVE BEEN DESIGNED IN ACCORDANCE WITH THE

RECOMMENDATIONS IN THE GEOTECHNICAL ENGINEERING REPORT, PREPARED BY CAPE FEAR

ENGINEERING AND DATED FEBRUARY 17, 2025.

2. PERFORM ALL EARTHWORK IN ACCORDANCE WITH THE RECOMMENDATIONS IN THE

GEOTECHNICAL ENGINEERING REPORT.

3. THE ENTIRE STRUCTURE MUST BE FOUNDED ON VERY WELL COMPACTED STRUCTURAL FILL OR

UNDISTURBED SOIL WITH A DESIGN ALLOWABLE NET BEARING PRESSURE OF 2000 P.S.F.

4. PRIOR TO PLACING FOUNDATION CONCRETE, ALL FOUNDATION EXCAVATIONS MUST BE

INSPECTED BY THE GEOTECHNICAL ENGINEER TO VERIFY THE EXTENT OF ANY LOOSE, SOFT, OR

UNSATISFACTORY SOIL AND TO VERIFY THE DESIGN BEARING PRESSURE. THE GEOTECHNICAL

ENGINEER WILL PROVIDE DIRECTION FOR CORRECTIVE ACTION WHERE REQUIRED.

5. DO NOT INSTALL FOUNDATION WORK UNTIL IT HAS BEEN COORDINATED WITH ADJACENT

UNDERGROUND UTILITIES. FOOTINGS MUST BE SLEEVED OR LOWERED WHERE REQUIRED. DO

NOT INSTALL UTILITIES UNDER ISOLATED COLUMN FOOTINGS. INSTALL UTILITIES

PERPENDICULAR TO WALL FOOTINGS.

6. DO NOT PUT IN UNBALANCED BACKFILL AGAINST FOUNDATION WALLS UNLESS WALLS ARE

SECURELY BRACED AGAINST OVERTURNING.

7. FROST LINE DEPTH IS 18” BELOW GRADE. BOTTOM OF EXTERIOR FOUNDATIONS MUST BEAR A

MINIMUM OF 18” BELOW FINAL GRADE. LOWER FOOTINGS AS REQUIRED TO MAINTAIN

COVERAGE.

CONCRETE MASONRY NOTES (CONTINUED):

1. MASONRY CONSTRUCTION MUST COMPLY WITH THE MASONRY SOCIETY “BUILDING CODE

FOR MASONRY STRUCTURES” (TMS 402-2016) AND “SPECIFICATION FOR MASONRY

STRUCTURES” (TMS 402/602-2016).

2. CONCRETE MASONRY UNITS MUST CONFORM TO ASTM C90 AND BE MADE WITH LIGHTWEIGHT

AGGREGATE. THE COMPRESSIVE STRENGTH OF MASONRY, F’m, EXPRESSED AS FORCE PER

UNIT OF NET CROSS-SECTIONAL AREA, MUST BE 2,000 PSI AT 28 DAYS.

3. MORTAR MUST CONFORM TO ASTM C270, TYPE S. AGGREGATE FOR MORTAR MUST COMPLY

WITH ASTM C144.

4. GROUT MUST CONFORM TO ASTM C476 AND MUST HAVE A MINIMUM 28 DAY COMPRESSIVE

STRENGTH OF 2,500 PSI. SLUMP AT POINT OF PLACEMENT MUST BE BETWEEN 8 AND 11

INCHES.

5. ALL REINFORCING BARS MUST CONFORM TO ASTM A615, GRADE 60. SHOP FABRICATED BARS SHOWN TO BE BENT OR HOOKED. BARS MUST BE LAPPED AS FOLLOWS: #4-20", #5-30", #6-54", #7-63", #8-72", #9-81".

6. REBAR DOWELS MUST BE THE SAME SIZE AND SPACING AS VERTICAL REINFORCING FROM

FOUNDATION. DOWELS MUST HAVE STANDARD ACI HOOKS.

7. PROVIDE BAR POSITIONERS FOR VERTICAL REINFORCING AT A MAXIMUM SPACING OF 200

BAR DIAMETERS, AT GROUT LIFT HEIGHTS, OR BAR SPLICE LOCATIONS, WHICHEVER IS LESS.

8. GROUTING MUST BE STOPPED 1-1/2" BELOW THE TOP OF A COURSE SO AS TO FORM A KEY AT

THE POUR JOINT.

9. ALL BOLTS, ANCHORS, ETC. PLACED IN THE WALL, MUST BE GROUTED SOLID INTO POSITION.

10. GROUT ALL CELLS SOLID BELOW FINISHED GRADE.

11. HORIZONTAL JOINT REINFORCING MUST BE STANDARD 9 GAGE LADDER TYPE IN CMU WALLS

AT 16” ON-CENTER. JOINT REINFORCING MUST COMPLY WITH ASTM A951.

DESIGN CRITERIA:

1. LOADS USED IN THE DESIGN OF THIS STRUCTURE ARE AS FOLLOWS:

2. UNIFORM LIVE LOADS:

SLAB ON GRADE 100 PSF

ROOF 20 PSF

3. ROOF SNOW LOADS:

GROUND SNOW LOAD Pg = 10 PSF SNOW EXPOSURE FACTOR Ce = 1.0

SNOW LOAD IMPORTANCE FACTOR I =1.0

THERMAL FACTOR Ct=1.0 FLAT ROOF SNOW LOAD: Pf = 7 PSF

RAIN ON SNOW SURCHARGE LOAD= 5 PSF

UNIFORM ROOF DESIGN SNOW LOAD: 7 PSF

4. WIND LOADS:

RISK CATEGORY = II

ULTIMATE WIND SPEED = 144 MPH

NOMINAL WIND SPEED (ASD) = 111.5 MPH

EXPOSURE CATEGORY (MAIN WINDFORCE-RESISTING SYSTEM): C

EXPOSURE CATEGORY (COMPONENTS AND CLADDING): C

INTERNAL PRESSURE COEFFICIENT: +/- 0.18 (ENCLOSED)

COMPONENTS AND CLADDING: WIND PRESSURE TO BE USED FOR DESIGN OF EXTERIOR

COMPONENTS AND CLADDING MATERIALS NOT SPECIFICALLY DESIGNED ON THESE

DRAWINGS MUST BE PER TABLE ON THIS SHEET.

5. SEISMIC LOADS:

RISK CATEGORY II

IMPORTANCE FACTOR I = 1.0

Ss = .115g S1 = .055g

SOIL SITE CLASS D

Sds = 0.123 Sd1 = 0.088

SEISMIC DESIGN CATEGORY B

BASIC SEISMIC FORCE RESISTING SYSTEM: ORDINARY REINFORCED MASONRY SHEAR WALLS

RESPONSE MODIFICATION FACTOR, R=2

SEISMIC RESPONSE COEFFICIENT, Cs = 0.061

DESIGN BASE SHEAR: 0.061W

ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL FORCE

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

C2

S-101

8" 4' - 0"

4' - 8"

(TYP)

1' - 0"

CONCRETE

FOOTING, REFER

TO SECTION

C2/S-101 FOR SIZE

AND REINFORCING

BRICK VENEER,

REFER TO ARCH

DWGS

8" CMU

#4 AT 32" OC VERTICAL

REINFORCING (TYP)

#4 CORNER VERTICAL

REINFORCING (TYP)

4' - 8"

3" CLR

C L R

8" CMU BOND BEAM

REINF WITH (2) #5 CONT

8" 8"

BRICK VENEER,

REFER TO ARCH

DWGS

PAVING, REFER

TO CIVIL DWGS

4" CMU

4" CONCRETE SLAB-ON-

GRADE REINF WITH 6x6 - W2.9xW2.9 WWF PLACED

1 1/2" CLEAR FROM TOP

ON STRUCTURAL FILL

DOWELS WITH STD

90° HOOK TO

MATCH VERT REINF

SIZE AND SPACING

1/2" PREMOLDED

JOINT FILLER

MATERIAL (TYP)

(5) #5 EACH WAY

TOP AND BOTTOM

BELL BY OTHERS

BELL TOWER CAP,

REFER TO ARCH DWGS

8" CMU, REFER

TO FOUNDATION

PLAN FOR REINF

FOR BELL HOUSING,

REFER TO ARCH DWGS

1/4

A2

S-101

8" 1' - 8" 8"

4" 1' - 0" 4"

#3 TIES AT 10" OC

(4) #5 DOWELS

(TYP)

BRICK VENEER,

REFER TO

ARCH DWGS

CONCRETE FOOTING,

REFER TO SECTION

A2/S-101 FOR SIZE

AND REINFORCING

3' - 0"

/4

BRICK VENEER,

REFER TO ARCH

DWGS

(4) #5 EACH WAY

TOP AND BOTTOM

(4) #5 DOWELS

#3 TIES AT 10" OC

MONUMENT CAP,

REFER TO ARCH

DWGS

3" CLR (TYP)

C L R

2" CLR

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

D E S

IG

N A

N D

C O

N S T R U

C T

IO

N

D C

C O

R E

N A V A L S

T A T

IO

N

N O

R F O

L K V A

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

J E

U N

E

N C n t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

L A

N T

IC

AS INDICATED

BELL

TOWER

BT

07 AUG 2025

C L o c a l R e v it F ile s \2

B T

S T

R U

C T js s

D

E .r v t

/7

/2

:1 :2

A

M

F O

U N

D A

T

IO

N P

L A

N A

N D

S E

C T

IO

N

S-101

1754108

C E

R E

M O

N

IA

L B

E L

L T

O W

E R

12932708

LWM JSS PDM

SCALE: 3/4" = 1'-0"C1

BELL TOWER FOUNDATION PLAN

SCALE: 3/4" = 1'-0"C2

SECTION

GRAPHIC SCALE: 3/4"=1'-0"

1' 0 1' 2' 3'

SCALE: 3/4" = 1'-0"A1

PARKING MONUMENT FOUNDATION PLAN

SCALE: 3/4" = 1'-0"A2

SECTION

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

N

DRAWING TAG

NORTH ARROW

EXTERIOR ELEVATION TAG

INTERIOR ELEVATION TAG

SECTION TAG

BUILDING SECTION TAG

DETAIL TAG

COLUMN GRID

DEMOLITION KEYNOTE TAG

CONSTRUCTION KEYNOTE TAG

ELEVATION BENCHMARK

WALL TYPE TAG

WINDOW TAG

DOOR TAG

ROOM NAME TAG

ROOF AREA TAG

DIMENSIONS

XX

DETAIL TITLE

SCALE: X" = 1'-0"

A

Room Name

A-101

XX

XX

XXXX

101A

0 '- 0"

ELEV

LOCATION COORDINATE

DETAIL TITLE

SCALE

PROJECT NORTH

TRUE NORTH

LOCATION COORDINATE

SHEET IDENTIFICATIONA-101

SHEET IDENTIFICATION

LOCATION COORDINATE

TYPICAL

LOCATION COORDINATE

SHEET IDENTIFICATIONA-101

A-101

A-101

LOCATION COORDINATE

TYPICAL

SHEET IDENTIFICATION

TYPICAL

LOCATION COORDINATE

SHEET IDENTIFICATION

COLUMN GRID NUMBER IDENTIFICATION

COLUMN GRID LETTER IDENTIFICATION

X

KEYNOTE NUMBER

KEYNOTE NUMBER

ELEVATION DIMENSION

ELEVATION DESCRIPTION

WALL TYPE IDENTIFIER

WINDOW TYPE IDENTIFIER

DOOR NUMBER

ROOM NAME

ROOM NUMBER

DIMENSIONED (WALL, FRAME, ETC.)

FACE OF ELEMENT BEING

DIMENSIONED (WALL, FRAME, ETC.)

CENTERLINE OF ELEMENT BEING

A-101

A ROOF AREA IDENTIFIER

AC AIR CONDITIONING

AB ANCHOR BOLT

ADA AMERICANS WITH DISABILITIES ACT

ABA ARCHITECTURAL BARRIERS ACT

AFF ABOVE FINISH FLOOR

AHJ AUTHORITY HAVING JURISDICTION

AHU AIR HANDLING UNIT

ALUM ALUMINUM

ALT ALTERNATE

ATC ACOUSTICAL TILE CEILING

AUX AUXILIARY

BD BOARD

BLDG BUILDING

BL BUILDING LINE

BRG BEARING

CFM CUBIC FEET PER MINUTE

CI CURB INLET / CAST IRON

CJ CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLR CLEAR

CM CENTIMETER

COL COLUMN

CONC CONCRETE

CPT CARPET

CY CUBIC YARD

DF DRINKING FOUNTAIN

DIA DIAMETER

DIAG DIAGONAL

DL DEAD LOAD

DN DOWN

DS DOWNSPOUT

DWG DRAWING

EA EACH / EXHAUST AIR

EJ EXPANSION JOINT

EJ/CJ EXPANSION JOINT & CONTROL JOINT

ELEV ELEVATION, ELEVATOR

ELEC ELECTRIC(AL)

EQ EQUAL

EQUP EQUIPMENT

EW EACH WAY

EX EXHAUST

EXTG EXISTING

EXT EXTERIOR

FA FIRE ALARM

FACP FIRE ALARM CONTROL PANEL

FAAP FIRE ALARM ANNUNCIATOR PANEL

FCU FAN COIL UNIT

FD FLOOR DRAIN

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FFE FINISHED FLOOR ELEVATION

FG FINISHED GRADE

FIN FINISH

FIXT FIXTURE

FLR FLOOR

FHB FREEZE-PROOF HOSE BIBB

FT FEET

GA GAGE

GALV GALVANIZED

GPM GALLONS PER MINUTE

GWB GYPSUM WALLBOARD

GYP GYPSUM

HB HOSE BIBB

HM HOLLOW METAL

ID INSIDE DIAMETER

IN INCH

INSUL INSULATION

INT INTERIOR

JT JOINT

LAV LAVATORY

LF LINEAR FEET

LL LIVE LOAD

LVT LUXURY VINYL TILE

MAX MAXIMUM

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

MO MASONRY OPENING

NEC NATIONAL ELECTRICAL CODE

NIC NOT IN CONTRACT

NO NUMBER

NTS NOT TO SCALE

OC ON CENTER

OPG OPENING

PWD PLYWOOD

PR PAIR

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

QT QUARRY TILE

RB RESILIENT BASE

RD ROOF DRAIN

REQ REQUIRED

REV REVERSE READ

READ

RM ROOM

RO ROUGH OPENING

ROW RIGHT OF WAY

SD SMOKE DETECTOR

SECT BUILDING SECTION

SHT SHEET

SIM SIMILAR

SQ SQUARE

SS STAINLESS STEEL

STD STANDARD

T&B TOP AND BOTTOM

T&G TONGUE AND GROOVE

TLT TOILET

TOS TOP OF STEEL

TYP TYPICAL

UH UNIT HEATER

UNO UNLESS NOTED OTHERWISE

VAV VARIABLE AIR VOLUME

VCT VINYL COMPOSITION TILE

W/ WITH

WD WOOD

WH WATER HEATER

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

D E S

IG

N A

N D

C O

N S T R

U C T

IO

N

D C

C O

R E

N A V A L S

T A T

IO

N

N O

R F O

L K V A

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

J E

U N

E

N C n t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

T

T C

E

TI

HCRAD

R E

G I S

ERE

A N

I

L

ORA

N O

R

T H

C

N

D A

R

N

DE

.J UE

ER

III

C

N

NRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

L A

N T

IC

AS INDICATED

M

A

P.

STCETIHCRA

FB

BERN N.C

.NEW

CERT. NO.

UTCETIHCRA

DERET

SI

G E R

N

OI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

BELL

TOWER

BT

S p ro je c ts

\2

\2

C

L M

A R

S O

C P

-1

M a n e u v e r

F a c ili ty S u b t o

N R

W \2

D e s ig n \2

D w g s \2

B

T A

R C

H

.r v t

/6

/2

:5

:4

P

M

S Y

M B

O L

L E

G E

N D

A N

D A

B B

R E

V

IA

T

IO

N S

A-001

1754108

C E

R E

M O

N

IA

L B

E L

L T

O W

E R

12932709

REL REL DJE,III

J. EMORY / J. BACE

07 AUG 2025

SYMBOL LEGEND ABBREVIATIONS

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

3' -4

1'

-0

1'-0" 3'-4" 1'-0"

B1

A-301

B1

A-301

A

TYP

CONCRETE APRON

ABOUND BELL

TOWER. LIGHT

BROOM FINISH

A-201

D4

A-201

D2

A-201

D1

A-201

D5

SEE THE SITE PLAN ON

THIS SHEET FOR

EXTENTS OF REMOVAL

AND REPLACEMENT

8" 1'-8" 8"

8" 1'

-8

8"

NOTES:

1. TYPICAL OF THREE (3) PARKING MONUMENTS

2. SEE CIVIL DRAWINGS FOR LOCATIONS AND

ROTATION AS RELATED TO THE CURB

B

TYP

1'-0" CONCRETE APRON

ABOUND PARKING

MONUMENT. LIGHT

BROOM FINISH

A-201

A2

A-201

A4

A-201

A1

A-201

A5

B4

A-301

B4

A-301

RR400

EQ EQ

A-101

A1

EXISTING MEMORIAL

WALL TO REMAIN.

PROTECT

EXISTING FLAGPOLE

TO REMAIN. PROTECT

EXISTING DECORATIVE

CONCRETE TO

REMAIN. PROTECT

EXISTING MEMORIAL

WALL TO REMAIN.

PROTECT

EXISTING FLAGPOLE TO

REMAIN. PROTECT

EXISTING FLAGPOLE TO

REMAIN. PROTECT

EXISTING BOLLARDS TO

REMAIN. PROTECT

EXISTING AT

BARRIER SYSTEM

TO REMAIN.

PROTECT

EXISTING AT

BARRIER SYSTEM

TO REMAIN.

PROTECT

H O

R S

E S

H O

E D

R

IV

E

SAW CUT AT EXISTING CONTROL JOINTS AND

REMOVE SLAB IDENTIFIED PORTION OF THE

EXISTING CONCRETE WALK TO ACCOMMODATE

INSTALLATION OF BELL TOWER FOOTING.

RESTORE CONCRETE WALK AND PROVIDE LIGHT

BROOM FINISH TO MATCH THE EXISTING

ADJACENT SURFACES

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

D E S

IG

N A

N D

C O

N S T R

U C T

IO

N

D C

C O

R E

N A V A L S

T A T

IO

N

N O

R F O

L K V A

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

J E

U N

E

N C n t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

T

T C

E

TI

HCRAD

R E

G I S

ERE

A N

I

L

ORA

N O

R

T H

C

N

D A

R

N

DE

.J UE

ER

III

C

N

NRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

L A

N T

IC

AS INDICATED

M

A

P.

STCETIHCRA

FB

BERN N.C

.NEW

CERT. NO.

UTCETIHCRA

DERET

SI

G E R

N

OI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

BELL

TOWER

BT

S p ro je c ts

\2

\2

C

L M

A R

S O

C P

-1

M a n e u v e r

F a c ili ty S u b t o

N R

W \2

D e s ig n \2

D w g s \2

B

T A

R C

H

.r v t

/6

/2

:5

:4

P

M

F L

O O

R P

L A

N S

C

O N

S T

R U

C T

IO

N

A-101

1754108

C E

R E

M O

N

IA

L B

E L

L T

O W

E R

12932710

REL REL DJE,III

J. EMORY / J. BACE

07 AUG 2025

GRAPHIC SCALE: 1/2"=1'-0"

2' 0 1' 2' 4'

SCALE: 1/2" = 1'-0"

A1

BELL TOWER PLAN

SCALE: 1/2" = 1'-0"

A3

TYPICAL PARKING MONUMENT PLAN

SCALE: 1" = 10'-0"

C3

BELL TOWER SITE PLAN

GRAPHIC SCALE: 1"=10'

10' 0 20'10'

N

N

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

4" GALVANIZED STEEL

TUBES WITH SHEET METAL

WRAP. TYPICAL

FACE BRICK

5" POLISHED BLACK GRANITE.

MUST MATCH THE GRANITE

AT THE MEMORIAL WALL

SHEET METAL FASCIA

STANDING SEAM

METAL ROOFING

2"

2 1/2"

5'-10" PERSON

FINISHED GRADE. SEE

CIVIL DRAWINGS

BRONZE BELL. GFCI

1' -1

3' -4

5"

2' -6

±6

±1

'-0

3' -9

7'

-9 " T

O

TA

L H

E

IG

H T

B1

A-301

B1

A-301

4" GALVANIZED STEEL

TUBES WITH SHEET METAL

WRAP. TYPICAL

FACE BRICK

5" POLISHED BLACK GRANITE.

MUST MATCH THE GRANITE

AT THE MEMORIAL WALL

SHEET METAL FASCIA

STANDING SEAM

METAL ROOFING

FINISHED GRADE. SEE

CIVIL DRAWINGS

BRONZE BELL.

GFCI

4" GALVANIZED STEEL

TUBES WITH SHEET METAL

WRAP. TYPICAL

FACE BRICK

5" POLISHED BLACK GRANITE.

MUST MATCH THE GRANITE

AT THE MEMORIAL WALL

SHEET METAL FASCIA

STANDING SEAM

METAL ROOFING

FINISHED GRADE. SEE

CIVIL DRAWINGS

BRONZE BELL.

GFCI

4" GALVANIZED STEEL

TUBES WITH SHEET METAL

WRAP. TYPICAL

FACE BRICK

5" POLISHED BLACK GRANITE.

MUST MATCH THE GRANITE

AT THE MEMORIAL WALL

SHEET METAL FASCIA

STANDING SEAM

METAL ROOFING

FINISHED GRADE. SEE

CIVIL DRAWINGS

BRONZE BELL.

GFCI

SHEET METAL PLACARD. 6"

FONT. CONFIRM COPY FOR

EACH PLACARD WITH

CONSTRUTION MANAGER

(DV1, DV2 & DV3)

FACE BRICK

PRECAST

CONCRETE CAP

FINISHED GRADE. SEE

CIVIL DRAWINGS

DVX

3"

2' -1

1" (1

C

O U

R S

E S

1"

B4

A-301

B4

A-301

NOTES:

1. FRONT ELEVATION FACES VEHICLE APPROACH DIRECTION

FACE BRICK

PRECAST

CONCRETE CAP

FINISHED GRADE. SEE

CIVIL DRAWINGS

FACE BRICK

PRECAST

CONCRETE CAP

FINISHED GRADE. SEE

CIVIL DRAWINGS

FACE BRICK

PRECAST

CONCRETE CAP

FINISHED GRADE. SEE

CIVIL DRAWINGS

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

D E S

IG

N A

N D

C O

N S T R

U C T

IO

N

D C

C O

R E

N A V A L S

T A T

IO

N

N O

R F O

L K V A

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

J E

U N

E

N C n t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

T

T C

E

TI

HCRAD

R E

G I S

ERE

A N

I

L

ORA

N O

R

T H

C

N

D A

R

N

DE

.J UE

ER

III

C

N

NRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

L A

N T

IC

AS INDICATED

M

A

P.

STCETIHCRA

FB

BERN N.C

.NEW

CERT. NO.

UTCETIHCRA

DERET

SI

G E R

N

OI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

BELL

TOWER

BT

S p ro je c ts

\2

\2

C

L M

A R

S O

C P

-1

M a n e u v e r

F a c ili ty S u b t o

N R

W \2

D e s ig n \2

D w g s \2

B

T A

R C

H

.r v t

/6

/2

:5

:5

P

M

E L

E V

A T

IO

N

S

A-201

1754108

C E

R E

M O

N

IA

L B

E L

L T

O W

E R

12932711

REL REL DJE,III

J. EMORY / J. BACE

07 AUG 2025

GRAPHIC SCALE: 1/2"=1'-0"

2' 0 1' 2' 4'

SCALE: 1/2" = 1'-0"

D1

BELL TOWER - NORTH ELEVATION

SCALE: 1/2" = 1'-0"

D2

BELL TOWER - EAST ELEVATION

SCALE: 1/2" = 1'-0"

D4

BELL TOWER - SOUTH ELEVATION

SCALE: 1/2" = 1'-0"

D5

BELL TOWER - WEST ELEVATION

SCALE: 1/2" = 1'-0"

A1

PARKING MONUMENT - FRONT ELEVATION

SCALE: 1/2" = 1'-0"

A2

PARKING MONUMENT - REAR ELEVATION

SCALE: 1/2" = 1'-0"

A4

PARKING MONUMENT - SIDE ELEVATION

SCALE: 1/2" = 1'-0"

A5

PARKING MONUMENT - SIDE ELEVATION

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

1' -1

4" GALVANIZED STEEL TUBE

POSTS WITH SHEET METAL

WRAP. TYPICAL

FACE BRICK

5" POLISHED BLACK GRANITE.

MUST MATCH THE GRANITE

AT THE MEMORIAL WALL

SHEET METAL FASCIA

AND SOFFIT WRAP

STANDING SEAM METAL

ROOFING. 12" WIDE

FLAT PANS. HAND SEAM

CONCRETE APRON. SEE

CIVIL DRAWINGS

STANDING SEAM

METAL ROOFING CAP

CONCRETE FOOTING. SEE

STRUCTURAL DRAWINGS

FOR REINFORCING

COMPACTED SUBGRADE

8" CMU. SEE STRUCTURAL

DRAWINGS FOR

REINFORCING AND FILL

FLASHING AND WEEPS

BACKER ROD AND

SEALANT

GROUT SOLID TO MIN 1/2"

ABOVE ADJACENT GRADE

ASYMMETRICAL OFFSET

BASE PLATES WITH (3)

1/2" DIA EMBED STUDS

5/8" TREATED PLYWOOD

SHEATHING SHEET METAL DRIP

EDGE

4" GALVANIZED STEEL TUBE

TOP FRAME WITH SHEET

METAL WRAP. TYPICAL

LIGHTING FIXTURES. SEE

ELECTRICAL DRAWINGS

3 5/8" LIGHT GAUGE

ROOF FRAMING

PROVIDE POLISHED BRONZE

EYE BOLT

BOX BEAM FOR BELL

SUPPORT. BELL IS ±45 LBS.

POLISHED BRONZE BELL. GFCI

ICE GUARD

UNDERLAYMENT

CUT HOLES IN GRANITE FOR

POSTS. TYPICAL

SEQUENCE NOTES:

1. INSTALL POSTS

2. INSTALL GRANITE OVER POSTS IN A FULL BED OF NON-SHRINK GROUT

3. LEAD-IN GAPS AROUND POSTS

4. WELD TOP FRAME TO POSTS. GRIND WELDS SMOOTH AND COLD GALVANIZE

5. ROUTE ELECTRICAL UP INSIDE OF ONE OF THE STEEL TUBE POSTS

EXPANSION JOINT. ALL SIDES

FACE BRICK

FINISHED GRADE. SEE

CIVIL DRAWINGS

CONCRETE FOOTING. SEE

STRUCTURAL DRAWINGS

FOR REINFORCING

COMPACTED SUBGRADE

12" SQUARE CAST IN PLACE

CONCRETE COLUMN. SEE

STRUCTURAL DRAWINGS

FOR REINFORCING

PRECAST CONCRETE CAP

3/

4"

NOTES:

1. EXPOSED SURFACES OF FOOTING TO RECEIVE A LIGHT BROOM FINISH

2. PRECAST CONCRETE TOP MAY BE DOWELED TO ELIMINATE MOVEMENT

GROUT COLLAR SOLID

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

D E S

IG

N A

N D

C O

N S T R

U C T

IO

N

D C

C O

R E

N A V A L S

T A T

IO

N

N O

R F O

L K V A

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

J E

U N

E

N C n t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

T

T C

E

TI

HCRAD

R E

G I S

ERE

A N

I

L

ORA

N O

R

T H

C

N

D A

R

N

DE

.J UE

ER

III

C

N

NRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

L A

N T

IC

AS INDICATED

M

A

P.

STCETIHCRA

FB

BERN N.C

.NEW

CERT. NO.

UTCETIHCRA

DERET

SI

G E R

N

OI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

BELL

TOWER

BT

S p ro je c ts

\2

\2

C

L M

A R

S O

C P

-1

M a n e u v e r

F a c ili ty S u b t o

N R

W \2

D e s ig n \2

D w g s \2

B

T A

R C

H

.r v t

/6

/2

:5

:5

P

M

S E

C T

IO

N

S

A-301

1754108

C E

R E

M O

N

IA

L B

E L

L T

O W

E R

12932712

REL REL DJE,III

J. EMORY / J. BACE

07 AUG 2025

GRAPHIC SCALE: 3/4"=1'-0"

1' 0 1' 2' 3'

SCALE: 3/4" = 1'-0"

B1

BELL TOWER SECTION

SCALE: 3/4" = 1'-0"

B4

PARKING MONUMENT SECTION

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

INSIDE CORNER

A-501 C5

A

CONTINUOUS WALL

B

3/8"

D E

P

TH

3/ 8"

TOOL A CONCAVE

JOINT PROFILE

SILICONE

SEALANT

BACKER ROD

3/8"

TOOL A CONCAVE

JOINT PROFILE

SILICONE

SEALANT

BACKER ROD

D E

P

TH

3/ 8"

CORNER

A

WALL

B

NOTES:

1. FLASHING CORNERS ARE TO BE SIMILAR AND SEALED WITH THE RECOMMENDED ADHESIVE OF

THE MANUFACTURER

2. FLASHING JOINTS SHALL OVERLAP 6" AND BE SEALED WITH RECOMMENDED ADHESIVE OF THE

MANUFACTURER

3. EXTEND FLASHING 8" MIN BEYOND OPENINGS

4. PROVIDE A TOOLED BEAD OF SYSTEM SEALANT AT MEMBRANE LAPS AND SPLICES

8"

VARIES

VARIES

8"

ONE

BRICK

COURSE

8"

VARIES

VARIES

8"

4" LAP

END DAM END LAPINSIDE CORNER OUTSIDE CORNER

A B C D

NOTES:

1. CENTER DRIP EDGE LAPS BETWEEN WEEPS

2. SIMILAR AT CMU

STAINLESS STEEL

DRIP EDGE

SOLID BRICKS ABOVE

WEEPS, TYPICAL

TWO WEEPS PER ELEVATION

WEEP, TYPICAL

4" BRICK VENEER

GROUT COLLAR SOLID

8" CONCRETE MASONRY UNIT

HORIZONTAL JOINT

REINFORCING 1'-4" ON

CENTER

GROUT CELLS SOLID

NOTES:

1. SEE STRUCTURAL DRAWINGS FOR REINFORCING

1'-0"

DAMPPROOFING

4" BRICK VENEER

GROUT COLLAR SOLID

GALVANIZED

CORRUGATED BRICK

TIES 1'-4" ON CENTER

EACH WAY

CAST IN PLACE CONCRETE

COLUMN. SEE STRCUTRAL

DRAWINGS

4"

1/2"

1/ 2"

GALVANIZED

STEEL POST

GALVANIZED STEEL

BASEPLATE. SEE

STRUCTURAL DRAWINGS

ANCHOR STUDS.

EMBED IN REINFORCED

AND FILL CMU CELL(S)

BRICK VENEER

BELOW

CMU BELOW

SHEET METAL WRAP

WITH LOCK SEAM

ROUTE

ELECTRICAL UP

INSIDE OF ONE

OF THE STEEL

TUBE POSTS

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

D E S

IG

N A

N D

C O

N S T R

U C T

IO

N

D C

C O

R E

N A V A L S

T A T

IO

N

N O

R F O

L K V A

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

J E

U N

E

N C n t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

T

T C

E

TI

HCRAD

R E

G I S

ERE

A N

I

L

ORA

N O

R

T H

C

N

D A

R

N

DE

.J UE

ER

III

C

N

NRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

L A

N T

IC

AS INDICATED

M

A

P.

STCETIHCRA

FB

BERN N.C

.NEW

CERT. NO.

UTCETIHCRA

DERET

SI

G E R

N

OI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

BELL

TOWER

BT

S p ro je c ts

\2

\2

C

L M

A R

S O

C P

-1

M a n e u v e r

F a c ili ty S u b t o

N R

W \2

D e s ig n \2

D w g s \2

B

T A

R C

H

.r v t

/6

/2

:5

:5

P

M

M

IS

C E

L L

A N

E O

U S

D E

T A

IL

S

A-501

1754108

C E

R E

M O

N

IA

L B

E L

L T

O W

E R

12932713

REL REL DJE,III

J. EMORY / J. BACE

07 AUG 2025

SCALE: 6" = 1'-0"

C3

CONTROL JOINTS DETAILS

SCALE: 1" = 1"

C5

SEALANT POCKET DETAILS

SCALE: 1 1/2" = 1'-0"

B4

SELF ADHERING FLASHING DETAIL

SCALE: 1" = 1'-0"

A5

WEEP VENT DETAIL

GRAPHIC SCALE: 1"=1"

0 1" 2"

GRAPHIC SCALE: 6"=1'-0"

0 3" 6"

GRAPHIC SCALE: 1 1/2"=1'-0"

1' 6" 3" 0 1'

GRAPHIC SCALE: 1"=1'-0"

1' 0 1' 2'

SCALE: 1 1/2" = 1'-0"

A

BELL TOWER WALL DETAIL

SCALE: 1 1/2" = 1'-0"

B

PARKING MONUMENT WALL DETAIL

SCALE: 1 1/2" = 1'-0"

B2

POST BASEPLATE

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

NOTES:

1. REFERENCE MCB CAMP LEJEUNE, BASE EXTERIOR

ARCHITECTURAL PLAN (BEAP) 2010, SECTION 4.12.3 MARSOC

HTTP://WWW.LEJEUNE.MARINES.MIL/PORTALS/27/DOCUMENTS/IDD/

BEAP/BEAP_CONTENTS.HTML#_TOC276453692

2. FINAL COLOR SELECTIONS MUST BE APPROVED AT THE

CONTRACTING OFFICER

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

D E S

IG

N A

N D

C O

N S T R

U C T

IO

N

D C

C O

R E

N A V A L S

T A T

IO

N

N O

R F O

L K V A

M A

R

IN

E C

O R

P S

B A

S E

C A

M P

L E

J E

U N

E

N C n t

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

T

T C

E

TI

HCRAD

R E

G I S

ERE

A N

I

L

ORA

N O

R

T H

C

N

D A

R

N

DE

.J UE

ER

III

C

N

NRB E

E W

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

A T

L A

N T

IC

AS INDICATED

M

A

P.

STCETIHCRA

FB

BERN N.C

.NEW

CERT. NO.

UTCETIHCRA

DERET

SI

G E R

N

OI

TA

RO

PR

OC

LAR

CAROLINANORTH

50679

BELL

TOWER

BT

S p ro je c ts

\2

\2

C

L M

A R

S O

C P

-1

M a n e u v e r

F a c ili ty S u b t o

N R

W \2

D e s ig n \2

D w g s \2

B

T A

R C

H

.r v t

/6

/2

:5

:5

P

M

S C

H E

D U

L E

O F

E X

T E

R

IO

R M

A T

E R

IA

L

S

A-601

1754108

C E

R E

M O

N

IA

L B

E L

L T

O W

E R

12932714

REL REL DJE,III

J. EMORY / J. BACE

07 AUG 2025

SCALE: NOT TO SCALE

A5

SCHEDULE OF EXTERIOR MATERIALS

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

DE

SI

GN

A

ND

C

ON

ST

RU

CT

IO

N

(D C)

C

OR

E

NA

VA

L

ST

AT

IO

N

- N

OR

FO

LK

, V A

M

AR

IN

E

C O

R

PS

B

AS

E C

AM

P

LE

JE

U N

E, N

C

Fi le

P at h Pr in t D at e:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

M

ID

AT

LA

N

TI

C

AS INDICATED

OF 16

1754108

P-

SO

F

IN

FO

R

M

AT

IO

N

M

AN

EU

VE

R F

AC

IL

IT

Y

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

U :\2

\B

IM

M

EP

\2

Be ll

To w er (c ad )\2

ES

1.

dw g

Au gu st

7,

- 1 1:

am

BELL

TOWER

BT

MM MM JEB

ES001

12932715

G

EN

ER

AL

N O

TE

S, L

EG

EN

D

, A

BB

R

EV

IA

TI

O N

S, A

N D

D

ET

AI

LS

WET LOCATION DOWNLIGHT FIXTURE

LIGHTING FIXTURE TYPE SYMBOL. SEE LIGHTING FIXTURE DETAILS.

ELECTRICAL CIRCUIT RUN IN CONDUIT AND CIRCUIT HOMERUN TO

PANELBOARD (PANEL AND CIRCUIT DESIGNATION AS INDICATED). AS A

MINIMUM CONDITION, EACH SINGLE PHASE CIRCUIT SHALL HAVE 1 #12 PHASE

CONDUCTOR, 1 #12 NEUTRAL CONDUCTOR AND 1 #12 GROUNDING CONDUCTOR

IN 1/2" CONDUIT. PROVIDE ADDITIONAL PHASE CONDUCTORS AS REQUIRED

FOR "MULTIPLE PHASED" ELECTRICAL LOADS. PROVIDE NEUTRAL CONDUCTOR

TO ALL WALL SWITCH OUTLET BOXES WHETHER REQUIRED OR NOT. PROVIDE

ADDITIONAL "SWITCH LEG" CONDUCTORS TO PROVIDE THE LIGHT FIXTURE

CONTROL INDICATED. MULTIPLE SINGLE PHASE CONDUCTORS MAY BE

GROUPED TOGETHER IN A COMMON CONDUIT IN ACCORDANCE WITH THE NEC

AND AT THE CONTRACTOR'S DISCRETION. GROUNDING CONDUCTORS MAY BE

SHARED AS ALLOWED BY THE NEC. NEUTRAL CONDUCTORS SHALL NOT BE

SHARED. MULTI-POLE BREAKERS SHALL BE PROVIDED IN ACCORDANCE WITH

THE NEC WHERE MULTI-WIRE BRANCH CIRCUITS ARE REQUIRED. CONDUIT

LARGER THAN 1/2" AND CONDUCTORS LARGER THAN #12 SHALL BE AS

INDICATED.

LIGHTING

GENERAL

WORK NOTE SYMBOL

PHOTOCELL, 1500W, 120V SPST, MOUNT ON ROOF, AIM NORTH

GENERAL ELECTRICAL NOTES ELECTRICAL LEGEND

AND

A

P

GENERAL: UNLESS SPECIFICALLY INDICATED OTHERWISE, ALL WORK

SHOWN ON ELECTRICAL DRAWINGS IS NEW WORK TO BE PROVIDED

UNDER THIS CONTRACT.

COORDINATION: COORDINATE AND COOPERATE WITH ALL TRADES ON

THE PROJECT. THE CONTRACTOR SHALL REVIEW ALL CONTRACT

DOCUMENTS INCLUDING CIVIL, STRUCTURAL, ARCHITECTURAL DRAWINGS

AND SPECIFICATIONS. CONTRACTOR SHALL COORDINATE AND ADJUST

ACCORDINGLY AS DIRECTED BY THE CONTRACTING OFFICER.

AS-BUILT DRAWINGS: SECURE AN EXTRA SET OF ELECTRICAL DRAWINGS

TO BE KEPT ON SITE AND MARK, DAILY, THE DRAWINGS IN RED AS THE

PROJECT PROGRESSES IN ORDER TO KEEP AN ACCURATE RECORD OF

ALL DEVIATIONS BETWEEN THE WORK SHOWN ON THE DRAWINGS AND

THE WORK WHICH IS ACTUALLY INSTALLED. THESE MARKED DRAWINGS

SHALL REFLECT ANY AND ALL CHANGES AND REVISIONS TO THE ORIGINAL

DESIGN WHICH EXISTS IN THE COMPLETED WORK. DELIVER THE MARKED

DRAWINGS TO THE ENGINEER AT PROJECT CLOSE-OUT.

TESTS: TEST ALL WIRING FOR CONTINUITY AND GROUNDS BEFORE

CONNECTING ANY FIXTURES OR DEVICES. PERFORM INSULATION

RESISTANCE TESTS ON ALL WIRING #6 OR LARGER TO ENSURE THAT ALL

PORTIONS ARE FREE FROM SHORT-CIRCUITS AND GROUNDS.

INSPECTIONS: ARRANGE ALL NECESSARY INSPECTIONS. DELIVER ALL

REQUIRED INSPECTION CERTIFICATES TO THE CONTRACTING OFFICER.

GROUNDING: PROVIDE GROUNDING IN ACCORDANCE WITH THE NEC FOR

THE ELECTRICAL SYSTEM INCLUDING EQUIPMENT FRAMES CONDUITS,

SWITCHES, CONTROLLERS, NEUTRAL CONDUCTORS, AND OTHER

EQUIPMENT. PROVIDE A GROUNDING CONDUCTOR IN ALL POWER

CONDUITS.

J-BOX LABELING: LABEL ALL JUNCTION BOXES WITH PERMANENT

MARKER IDENTIFYING CIRCUIT NUMBER AND PANELBOARD OF CIRCUITS

WITHIN.

LIGHTING COORDINATION: COORDINATE LIGHTING FIXTURES WITH BELL

STRUCTURE. PROVIDE FIXTURE MOUNTING BRACKETS, ACCESSORIES,

ETC.

CLEAN UP: ON PROJECT CLOSE-OUT CLEAN ALL LIGHTING FIXTURES,

LENSES, AND REMOVE ALL PAINT SPATTERS FROM FIXTURES. REPAIR ALL

INOPERATIVE LIGHTING FIXTURES.

ABBREVIATIONS

A AMPERE

AFG ABOVE FINISHED GRADE

AIC AMPERE INTERRUPTING CAPACITY

AWG AMERICAN WIRE GAUGE

BFG BELOW FINISHED GRADE

C CONDUIT

CKT CIRCUIT

ETR EXISTING TO REMAIN

EXIST EXISTING

FLA FULL LOAD AMPS

GND GROUND

IBC INTERNATIONAL BUILDING CODE

KAIC THOUSAND AMPERE

INTERRUPTING CAPACITY

KVA KILO-VOLT-AMPERES

KW KILO-WATTS

LF LINEAR FEET

LTG LIGHTING

MCA MINIMUM CIRCUIT AMPS

MFR MANUFACTURER

MIN MINIMUM

MLO MAIN LUGS ONLY

MTD MOUNTED

N NORMAL

NEC NATIONAL ELECTRICAL CODE

NFPA NATIONAL FIRE PROTECTION

ASSOCIATION

NTS NOT TO SCALE

OC ON CENTER

P POLE

PF POWER FACTOR

PL PROPERTY LINE

PNL PANEL

Ø PHASE

PRI PRIMARY

PVC POLYVINYL CHLORIDE

SCH SCHEDULE

TYP TYPICAL

UFC UNIFIED FACILITIES CRITERIA

UON UNLESS OTHERWISE NOTED

V VOLT

W WATTS/WIRE

WP WEATHERPROOF

LIGHTING FIXTURE SCHEDULE

TYPE MARK DESCRIPTION MOUNTING BASIS OF DESIGN LAMP TYPE WATTAGE VOLTAGE COMMENTS

1" ADJUSTABLE DOWNLIGHT RECESSED

FIXTURE WITH 630 LUMEN OUTPUT, 0-10V 1%

DIMMING AND 90 CRI AT 3500 COLOR

TEMPERATURE, 55° BEAM ANGLE

LED 7 120/277 COORDINATE FIXTURE MOUTING WITH STRUCTURE.

PROVIDE FIXTURE WITH DIFFUSED LENS.A

SEAL

E

GE N

PROF

ON RTH

E RN EI

AC

L

NANOIS AS

IOR L

048848

07 AUG 2025

EXTERIOR ADJUSTABLE DOWNLIGHT

REVISED: XL-27LIGHTING PLATE:AUGUST 2025

A

NOTE: THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN MANUFACTURER OR PREFERENCE.

LUMINAIRE DESCRIPTION:

1. HOUSING - HEAVY GAUGE COLD ROLLED STEEL AND DIE CAST ALUMINUM WITH POWDER COATING

FINISH.

2. OPTICS - ACRYLIC LENS.

3. LIGHT SOURCE - SOLID STATE LEDS, 3000K CCT UON, MINIMUM 80 CRI UON, AND A MINIMUM

EFFICACY OF 90 LUMENS/WATT UON. INITIAL LUMEN OUTPUT AS INDICATED IN LUMINAIRE

SCHEDULE.

4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DIMMABLE DRIVER WITH MINIMUM 0.9 PF, OPERATING VOLTAGE OF 120 OR 277V, THERMAL MANAGEMENT, AND < 20% THD. ON-OFF

CONTROL AND FULLY DIMMABLE DOWN TO 10% MINIMUM OR AS INDICATED IN LUMINAIRE

SCHEDULE.

5. CERTIFICATION - UL LISTED FOR DAMP OR WET LOCATION, ROHS COMPLIANT. COMPLIES WITH IES

LM79, LM80 AND TM21 TESTING STANDARDS.

6. MOUNTING - RECESSED IN HARD CEILINGS.

A

SATISFACTORY TO

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

EPROJECT NO.:

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

DE

SI

GN

A

ND

C

ON

ST

RU

CT

IO

N

(D C)

C

OR

E

NA

VA

L

ST

AT

IO

N

- N

OR

FO

LK

, V A

M

AR

IN

E

C O

R

PS

B

AS

E C

AM

P

LE

JE

U N

E, N

C

Fi le

P at h Pr in t D at e:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G

S

YS

TE

M

S C

O M

M

AN

D

M

ID

AT

LA

N

TI

C

AS INDICATED

OF 16

1754108

P-

SO

F

IN

FO

R

M

AT

IO

N

M

AN

EU

VE

R F

AC

IL

IT

Y

SY

M

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

U :\2

\B

IM

M

EP

\2

Be ll

To w er (c ad )\2

ES

1.

dw g

Au gu st

7,

- 1 1:

am

BELL

TOWER

BT

MM MM JEB

ES101

12932716

SI

TE

L

AY

O U

T

PL

AN

N

ELECTRICAL SITE PLAN

SCALE: 1" = 10'

CONTRACTOR MUST COORDINATE FIXTURE MOUNTING WITH

STRUCTURAL DRAWINGS.

CONNECT FIXTURE TO EXISTING PHOTOCELL-CONTROLLED

EXTERIOR LIGHTING CIRCUIT.

NOTES THIS SHEET

SEAL

E

GE N

PROF

ON RTH

E RN EI

AC

L

NA

NOIS AS

IOR L

048848

07 AUG 2025

GENERAL
G-001 - TITLE SHEET
G-002 - LOCATION MAPS, NOTES AND INDEX OF DRAWINGS
CIVIL
C-001 CIVIL LEGEND, ABBREVIATIONS AND NOTES
C-100 OVERALL SITE PLAN
CS101 SITE LAYOUT PLAN
CS501 DETAILS
STRUCTURAL
S-001 - GENERAL NOTES
S-101 - FOUNDATION PLAN AND SECTION
ARCHITECTURAL
A-001 - SYMBOL LEGEND AND ABBREVIATIONS
A-101 - FLOOR PLANS - CONSTRUCTION
A-201 - ELEVATIONS
A-301 - SECTIONS
A-501 - MISCELLANEOUS DETAILS
A-601 - SCHEDULE OF EXTERIOR MATERIALS
ELECTRICAL
ES001 GENERAL NOTES, LEGEND, ABBREVIATIONS, AND DETAILS
ES101 ELECTRICAL SITE PLAN

File details come from the government source that posted it. Updated .