24-8314_Bid_Schedule_R1.xlsx
XLSX spreadsheet 22 KB Posted
- Solicitation number
- 24-8314
- Issued by
- Collier County, Florida
About this file
This is a bid schedule for Collier County, Florida's construction of the BCIRP Phase 2A Signalized Intersection project on Oil Well Road at Big Corkscrew Drive (Bid No. 24-8314). The project encompasses six major sections of work: general mobilization and project initiation items; demolition and erosion control; paving and sidewalk improvements totaling 2,870 square yards of asphalt and concrete work; storm drainage installation including 273 linear feet of 18-inch reinforced concrete pipe; potable water distribution system modifications; and comprehensive signalization installation featuring traffic signal equipment, detection systems, lighting, CCTV cameras, and associated infrastructure. The bid schedule itemizes 112 line items across all sections with specified quantities for each component. A non-mandatory pre-bid meeting is scheduled for November 12, 2024, at 10:00 a.m., with sealed bids due December 12, 2024, at 3:00 p.m. local time. The project requires substantial completion within 195 calendar days and final completion within 30 calendar days thereafter.
The anticipated project estimate is $4,724,898.03, with the county allocating an additional $200,000 owner's allowance for unforeseen conditions or owner-directed work. Mobilization and demobilization costs are capped at 5 percent of the respective bid totals. Bidders must submit a 5 percent bid bond or certified/cashier's check, with successful contractors required to provide 100 percent payment and performance bonds. Liquidated damages are assessed at $2,512 per calendar day for failure to achieve substantial completion on schedule. The project is funded through Parks and Recreation Impact Fees, with the adjacent commercial developer responsible for reimbursing Collier County for portions of public utilities and intersection costs. Work hours are restricted to 7:00 a.m. to 7:00 p.m., Monday through Friday. Contractors must maintain comprehensive insurance coverage including commercial general liability, workers' compensation, and automobile liability, and comply with FDOT 2023 design standards, ADA requirements, and Florida Building Code standards.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BidSch
| BCIRP Phase 2A Signalized Intersection on Oil Well at Big Corkscrew Dr. | |||||
| Construction ITB No. 24-8314 | |||||
| Bid Schedule | |||||
| Item No. | Description | Unit | Quantity | Price | Total |
| Section 1 - General | |||||
| 1.1 | Mobilization/Demobilization | LS | 1 | $ - 0 | $ - 0 |
| 1.2 | Maintenance of Traffic | LS | 1 | $ - 0 | |
| 1.3 | Survey | LS | 1 | $ - 0 | |
| 1.4 | Pre-Construction Video and Photographs | LS | 1 | $ - 0 | |
| 1.5 | Project Sign - Furnish and Install | EA | 1 | $ - 0 | |
| Section 1 Subtotal: | $ - 0 | ||||
| Section 2 - Demolition & Erosion Control | |||||
| 2.1 | Silt Fence | LF | 605 | $ - 0 | |
| 2.2 | Turbidity Barrier | LF | 94 | $ - 0 | |
| 2.3 | Curb Inlet Protection | EA | 4 | $ - 0 | |
| 2.4 | Remove/Dispose Existing Concrete Sidewalk | SF | 2,975 | $ - 0 | |
| 2.5 | Remove/Dispose Existing Curb and/or Gutter | LF | 974 | $ - 0 | |
| 2.6 | Remove/Dispose Existing Pavement | SY | 263 | $ - 0 | |
| Section 2 Subtotal: | $ - 0 | ||||
| Section 3 - Paving & Sidewalk Improvements | |||||
| 3.1 | Earthwork and Site Grading | LS | 1 | $ - 0 | |
| 3.2 | 12" Stabilized Subgrade | SY | 2,870 | $ - 0 | |
| 3.3 | 10" Limerock Base (Compacted and Primed) | SY | 2,870 | $ - 0 | |
| 3.4 | 3" Type SP-12.5 Structural Course (2-1.5 inch Lifts) | SY | 2,870 | $ - 0 | |
| 3.5 | 1" Type SP-9.5 Surface Course | SY | 2,870 | $ - 0 | |
| 3.6 | Type "A" Curb | LF | 554 | $ - 0 | |
| 3.7 | Type "F" Curb & Gutter | LF | 917 | $ - 0 | |
| 3.8 | Concrete Median 5" thick | SY | 114 | $ - 0 | |
| 3.9 | 6" Thick Concrete Sidewalk | SY | 377 | $ - 0 | |
| 3.10 | Detectable Warnings for Ramps | EA | 10 | $ - 0 | |
| 3.11 | Remove and Relocate Existing Light Poles | EA | 2 | $ - 0 | |
| 3.12 | Bahia Sod | SY | 2,830 | $ - 0 | |
| 3.13 | Single Post Sign, F&I Ground Mount, Up to 12 SF | EA | 10 | $ - 0 | |
| 3.14 | Pavement Markings | LS | 1 | $ - 0 | |
| 3.15 | RPM's, F&I | LS | 1 | $ - 0 | |
| 3.16 | Paint Median Noses | EA | 3 | $ - 0 | |
| Section 3 Subtotal: | $ - 0 | ||||
| Section 4 - Storm Drainage | |||||
| 4.1 | 18" RCP | LF | 273 | $ - 0 | |
| 4.2 | FDOT Curb Inlet Type 6 | EA | 1 | $ - 0 | |
| 4.3 | Junction Box with 2' Sump | EA | 2 | $ - 0 | |
| 4.4 | Connect 18" RCP to Existing Curb Inlet | EA | 2 | $ - 0 | |
| 4.5 | 18" Mitered End Section 2:1 (Cross Drain) | EA | 2 | $ - 0 | |
| Section 4 Subtotal: | $ - 0 | ||||
| Section 5 - Potable Water Distribution System | |||||
| 5.1 | Remove/Replace 12" PVC DR 14 Water Main at Conflict | LF | 54 | $ - 0 | |
| 5.2 | Air Release Valve on Existing 12" Main | EA | 4 | $ - 0 | |
| Section 5 Subtotal: | $ - 0 | ||||
| Section 6 - Signalization Installation | |||||
| 630-2-11 | CONDUIT (F&I) (UNDERGROUND) | LF | 217 | $ - 0 | |
| 630-2-12 | DIRECTIONAL BORE (F&I) | LF | 403 | $ - 0 | |
| 632-7-1 | SIGNAL CABLE (F&I) | PI | 1 | $ - 0 | |
| 633-1-122 | ITS FIBER OPTIC CABLE (F&I) (UNDERGROUND) (13-48 FIBERS) | LF | 40 | $ - 0 | |
| 633-3-11 | ITS FIBER OPTIC CONNECTION HARDWARE (F&I) (SPLICE ENCLOSURE) | EA | 1 | $ - 0 | |
| 633-3-12 | ITS FIBER OPTIC CONNECTION HARDWARE (F&I) (SPLICE TRAY) | EA | 4 | $ - 0 | |
| 633-3-14 | ITS FIBER OPTIC CONNECTION HARDWARE (F&I) (BUFFER TUBE FAN OUT KIT) | EA | 1 | $ - 0 | |
| 633-3-15 | ITS FIBER OPTIC CONNECTION HARDWARE (F&I) (PATCH PANEL, PRETERMINATED) | EA | 1 | $ - 0 | |
| 633-8-1 | MULTI-CONDUCTOR COMMUNICATION CABLE | LF | 5 | $ - 0 | |
| 635-2-11 | PULL BOX (F&I) (13"X24" COVER SIZE) | EA | 4 | $ - 0 | |
| 635-2-11A | PULL BOX (F&I) (17"X30" COVER SIZE) | EA | 9 | $ - 0 | |
| 635-2-12 | PULL BOX (F&I) (24"x36" COVER SIZE) | EA | 1 | $ - 0 | |
| 639-1-122 | ELECTRICAL POWER SERVICE (F&I) (UNDERGROUND) | AS | 1 | $ - 0 | |
| 639-2-1 | ELECTRICAL SERVICE WIRE (F&I) | LF | 300 | $ - 0 | |
| 641-2-12 | PRESTRESSED CONCRETE POLE (F&I) (TYPE P-II SERVICE) | EA | 1 | $ - 0 | |
| 646-1-11 | ALUMINUM SIGNAL POLE (PEDESTAL) | EA | 8 | $ - 0 | |
| 649-21-10 | STEEL MAST ARM ASSEMBLIES (SINGLE ARM 60') Furnish Materials | EA | 2 | $ - 0 | |
| 649-21-10 | STEEL MAST ARM ASSEMBLIES (SINGLE ARM 60') Coordination and Installation | EA | 2 | $ - 0 | |
| 649-21-21 | STEEL MAST ARM ASSEMBLIES (SINGLE ARM 78') Furnish Materials | EA | 2 | $ - 0 | |
| 649-21-21 | STEEL MAST ARM ASSEMBLIES (SINGLE ARM 78') Coordination and Installation | EA | 2 | $ - 0 | |
| 650-1-14 | TRAFFIC SIGNAL 12" STD. (F&I) (ALUMINUM) (3 SECTION, 1-WAY) | AS | 9 | $ - 0 | |
| 650-1-16 | TRAFFIC SIGNAL 12" STD. (F&I) (ALUMINUM) (4 SECTION, 1-WAY) | AS | 2 | $ - 0 | |
| 653-1-11 | PEDESTRIAN SIGNAL (F&I) (LED COUNTDOWN) (1 WAY) | AS | 8 | $ - 0 | |
| 660-1-110 | INDUCTIVE LOOP DETECTOR (F&I) | EA | 6 | $ - 0 | |
| 660-2-106 | LOOP ASSEMBLY (TYPE F) (40 FOOT) | AS | 10 | $ - 0 | |
| 660-3-11 | VEHICLE DETECTION SYSTEM - MICROWAVE (F&I) (CABINET EQUIPMENT) | EA | 1 | $ - 0 | |
| 660-3-12 | VEHICLE DETECTION SYSTEM - MICROWAVE (F&I) (ABOVE GROUND EQUIPMENT) | EA | 2 | $ - 0 | |
| 663-1-111 | SIGNAL PRIORITY AND PREEMPTION SYSTEM (F&I), (OPTICOM), (CABINET ELECTRONICS) | EA | 1 | $ - 0 | |
| 663-1-112 | SIGNAL PRIORITY AND PREEMPTION SYSTEM (F&I) (OPTICOM), (DETECTOR) | EA | 4 | $ - 0 | |
| 665-1-11 | DETECTOR, PEDESTRIAN (F&I) (STANDARD) | EA | 8 | $ - 0 | |
| 671-2-11 | Traffic Controller (Controller withouut Cabinet) (F&I) | EA | 1 | $ - 0 | |
| 676-1-17 | Traffic Signal Controller Cabinet (Cabinet without Controller) (F&I) | EA | 1 | $ - 0 | |
| 682-1-133 | ITS CCTV CAMERA (F&I) (DOME ENCLOSURE) (NON-PRESSURIZED) (BOSCH) | EA | 2 | $ - 0 | |
| 684-1-1 | ETHERNET SWITCH (F&I) | EA | 1 | $ - 0 | |
| 685-1-13 | SYSTEM AUXILIARIES (F&I) (UNINTERRUPTIBLE POWER SOURCE) | EA | 1 | $ - 0 | |
| 700-2-12 | MULTI COLUMN (POST) GROUND SIGN (F&I) (12.0-20.0 SQ. FT) | AS | 1 | $ - 0 | |
| 700-2-14 | MULTI COLUMN (POST) GROUND SIGN (F&I) (30.1-50.0 SQ. FT) | AS | 2 | $ - 0 | |
| 700-5-22 | INTERNALLY ILLUMINATED STREET NAME SIGN (F&I) (OVERHEAD MOUNT) (12-18 SF) | EA | 2 | $ - 0 | |
| 700-5-22A | INTERNALLY ILLUMINATED STREET NAME SIGN (F&I) (OVERHEAD MOUNT) (MORE THAT 18 SF) | EA | 2 | $ - 0 | |
| 715-4-74 | LIGHT POLE COMPLETE (LUMINAIRE, POLE, FOUNDATION) | EA | 1 | $ - 0 | |
| 715-5-31 | LUMINAIRE AND BRACKET ARM (F&I) (ALUMINUM) | EA | 4 | $ - 0 | |
| Section 6 Subtotal: | $ - 0 | ||||
| Total Base Bid: | $ - 0 | ||||
| Bid Alternate | |||||
| A1 | Temporary Signalization | LS | 1 | $ - 0 | |
| Total Alternate: | $ - 0 | ||||
| Total Base Bid + Alternate | $ - 0 |
*Note: The scheduled value for mobilization plus demobilization shall not exceed 5 percent of the Base Bid Project Total. **Note: The scheduled value for mobilization plus demobilization shall not exceed 5 percent of the Bid Alternate Total.
Staff has allocated $200,000.00 in Owner's Allowance - for Owners Use as Directed. This Allowance will be used only at the Owner's direction to accomplish work due to unforeseen conditions and/or as directed by the Owner. Inclusion of the Allowance as part of the Contract Price is not a guarantee that the Contractor will be paid any portion or the full amount of the Allowance. Expenditures of Owners Allowance will be made through Change Order with proper documentation of Time and Materials supporting the change.
&"-,Bold"&11Big Corkscrew Island Regional Park - Phase 2
&14BID SCHEDULE&11
Oil Well Road - Big Corkscrew Drive Intersection Improvements&12 &10September 27, 2024
&8&D &"-,Regular"&8&Z&F &"-,Regular"Page &P
File details come from the government source that posted it. Updated .