24-4615 Final Submittal B252 Edits.pdf
PDF 2 MB Posted
- Attached to
- Industry Day - KC 46 Furniture
- Solicitation number
- FA481425TF022
About this file
This is a set of electrical specifications and drawings for converting an Education Center to an Airborne Life Support (ALS) facility at MacDill Air Force Base in Florida (Building 252). The drawing package includes detailed electrical specifications, floor plans, power and systems layouts, lighting fixtures, fire alarm requirements, and communications infrastructure for both the first and second floors of the facility.
The specifications detail requirements for circuit breakers, panelboards, grounding systems, raceways, wiring devices, lighting controls, surge protection, and a complete addressable fire alarm/mass notification system. Key infrastructure elements include new electrical panels, CAT6 cabling infrastructure with patch panels, emergency lighting, and AV system pre-wiring. The drawings show detailed room layouts with furniture and equipment placement, requiring specific power and data drops for workstations, training areas, and collaborative spaces. Multiple electrical panels (RP1-RP6) are specified to serve different areas of the facility, with dedicated circuits for HVAC equipment, lighting, and receptacles. The project requires compliance with Air Force facility standards and includes integration with existing building systems.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| KC-46 Industry Questions and Talking Points.pdf | ||
| RFQ Bid Spreadsheet V2.0.xlsx | XLSX spreadsheet | |
| B55 Furniture Floor Plan.pdf | ||
| Industry Day - KC-46 Base Pass Requests.xlsx | XLSX spreadsheet | |
| 2024.08.14_MacDill_Furniture information_B53_B56_B6 Revised.pdf | ||
| INDUSTRY DAY - SOURCES SOUGHT KC-46 Furniture.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONDOR ST
HILLSBOROUGH LOOP DR
SN
O
W Y
EG
R
ET
S
T
'E' P L
CONDOR ST
APRON ACCESS RD
HILLSBOROUGH LOOP DR
SE
M
IN
O
LE
IN
D
IA
N P
L
ADMINISTRATION AVE
P/A
P/A
P/A
P/A
P/A
P/A
P/A
P/A
P/A
P/A
P/A
P/A
HANGAR LOOP DR
O
LE
AN
D
ER
P
L
P/A
P/A
P/A
P/A
P/A
P/A
P/A
Sheet of
Sheet No.
Drawing Index DescriptionSheet
PROJECT LOCATION MAP
NVZR:
HOWARD FRANKLAND BRIDGE
BASE CONTRACTING
TAMPA
PORT
BLDG 147
ROUTE
MILES
MACDILL AFB
BAYSHORE
M
AC
D
IL
L
HAUL
HILLSBOROUGH BAY
HENDERSON
AIRPORT
INTERNATL.
TAMPA
KENNEDY
VICINITY MAP
GANDY BRIDGE M
AN
H
AT
TA
N
ST. PETERSBURG
TO
CLEARWATER
TO TAMPA
52 3 41 0 1
TAMPA BAY
D
AL
E M
AB
R
Y
6th CIVIL ENGINEER SQUADRON
MACDILL AIR FORCE BASE, FLORIDA
Ground Safety
Using Agency
Fire Department
Environmental Engineering
Security Forces
Bioenvironmental
Communications Squadron
Chief of Operations & Maintenance
CADD Drawing Name:
Facility I.D.
Chief of Engineering
Chief of Construction Management
Base Civil Engineer
Sheet No.
Antiterrorism Force Protection
N
N O
R
TH
M
AG
D ec
5,
- 9
:0 2a m b y
E O
:\D R
AW
IN
G S\
Pr oj ec tN um be r\2 4-
\G -0
.d w g
BASE CIVIL ENGINEERS
BLDG 30
PROJECT SITE
MACDILL AFB, FL
8102 CONDOR ST
33621
AC
M
D
EC
SEE SHEET G-004 & G-005 FOR DRAWING INDEX CONTINUATION
1 G-001 COVER SHEET AND INDEX OF DRAWINGS
2 G-002 HAUL ROUTE AND ABBREVIATIONS
3 G-003 GENERAL NOTES AND SYMBOLS LEGEND
4 G-004 DRAWINGS INDEX (CONTINUED)
5 G-005 DRAWINGS INDEX (CONTINUED)
6 G-006 DRAWINGS INDEX (CONTINUED)
7 G-007 1ST FLOOR LIFE SAFETY PLAN
8 G-008 2ND FLOOR LIFE SAFETY PLAN
9 C-001 CIVIL SPECIFICATIONS
10 C-002 CIVIL SPECIFICATIONS
11 C-003 CIVIL SPECIFICATIONS
12 C-101 DEMOLITION SITE PLAN
13 C-102 SITE PLAN
14 C-103 UTILITIES PLAN
PROJECT NO. NVZR
G-001
G-001.dwg
CONVERT ED CENTER TO ALS B252
24-4615
15 DEC 23
24-4615
200 4000 100
FEET
N
N O
R
TH
M
AG
FINAL - APPROVED
FOR CONSTRUCTION
AutoCAD SHX Text D
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text Y
AutoCAD SHX Text T
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text
REV
CIRCUIT BREAKERS
ALL CIRCUIT BREAKERS SHALL BE UL LABELED AND SHALL BE THERMAL AND
MAGNETIC, MOLDED CASE TYPE, QUICK-MAKE AND QUICK-BREAK BOTH ON
MANUAL AND ON AUTOMATIC OPERATION AND SHALL BE BOLTED TO THE PANEL
BUS. BREAKERS SHALL BE THE OVER-THE-CENTER TOGGLE OPERATING TYPE,
WITH THE HANDLE GOING TO A POSITION BETWEEN "ON" AND "OFF" TO IN-
DICATE AUTOMATIC TRIPPING. ALL MULTI-POLE BREAKERS SHALL BE IN-
TERNAL COMMON TRIP. ALL BREAKERS FOR HVAC EQUIPMENT SHALL BE
LISTED AS "HACR" TYPE. THE BREAKERS TO BE FURNISHED SHALL, IN
EACH INSTANCE, BE DETERMINED BY THE SPECIFICATIONS, THE AMPACITY
AND POLES IN SCHEDULES OR AS INDICATED, AND BY THE MINIMUM UL
LABELED RMS SYMMETRICAL AMPERES INTERRUPTING CAPACITY AT CIRCUIT
VOLTAGE AS INDICATED BY THE SCHEDULES BUT IN NO CASE LESS THAN
10,000 RMS SYMMETRICAL AMPERES. HOWEVER, THE MINIMUM INTERRUPT-
ING RATING OF CIRCUIT BREAKERS USED AS FEEDERS AND BRANCHES SHALL
BE IN ACCORDANCE WITH PRESCRIBED UL RECOGNIZED SERIES CONNECTED
CIRCUIT BREAKERS COMBINATIONS. ALL ELECTRICAL EQUIPMENT USING
THESE UL RECOGNIZED CIRCUIT BREAKER COMBINATIONS SHALL BE CLEARLY
MARKED INDICATING SAME. NEMA RATINGS ARE NOT ACCEPTABLE IN LIEU
OF UL RATINGS. BREAKERS SHALL BE LABELED AS REQUIRED BY THE NEC.
PROVIDE WITH MECHANICAL SCREW TYPE REMOVABLE CONNECTOR LUGS, AL/CU
RATED. INSTALL OVERCURRENT PROTECTIVE DEVICES AS INDICATED, IN
ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND WITH
RECOGNIZED INDUSTRY PRACTICES TO ENSURE THAT PROTECTIVE DEVICES
COMPLY WITH REQUIREMENTS. COMPLY WITH NEC AND NEMA STANDARDS FOR
INSTALLATION OF OVERCURRENT PROTECTIVE DEVICES. ALL MOLDED CASE
MAIN CIRCUIT BREAKERS SHALL BE VERTICALLY MOUNTED. ALL VERTICALLY
MOUNTED MOLDED CASE CIRCUIT BREAKERS SHALL BE MOUNTED SO THE
HANDLE IS UP FOR "ON" AND DOWN FOR "OFF", WHEN VIEWED FROM THE
NORMAL STANDING POSITION.
PANELBOARDS
PANELBOARDS SHALL BE OF THE DEAD-FRONT TYPE INCORPORATING SWITCH-
ING AND PROTECTIVE DEVICES OF THE NUMBER, RATING AND TYPE SPECI-
FIED HEREIN OR SHOWN ON THE DRAWINGS. PANELBOARDS SHALL HAVE GEN-
ERAL PURPOSE ENCLOSURES AND SHALL BE SUITABLE FOR FLUSH OR SURFACE
MOUNTING AS INDICATED. ALL PANELBOARDS SHALL BE RATED FOR THE IN-
TENDED VOLTAGE AND SHALL BE IN ACCORDANCE WITH THE UNDERWRITER'S
LABORATORIES, INC. (UL) STANDARDS UL 50 "STANDARD FOR SAFETY,
PANELBOARDS" AND UL 67 "STANDARD FOR SAFETY, CABINETS AND BOXES"
AND SHALL BE SO LABELED WHERE PROCEDURES EXIST. WHERE PANELBOARDS
ARE TO BE USED AS SERVICE ENTRANCE EQUIPMENT, THEY SHALL BE SO
LABELED. PANELBOARDS SHALL ALSO COMPLY WITH NEMA PB 1 "PANEL-
BOARDS", NATIONAL ELECTRICAL CODE, AND FEDERAL SPECIFICATION
FS-W-P-115A "POWER DISTRIBUTION PANELS" WHERE APPLICABLE. ALL
INTERIORS SHALL BE COMPLETELY FACTORY ASSEMBLED WITH SWITCHING
AND PROTECTIVE DEVICES, WIRE CONNECTORS, ETC. ALL WIRE CONNECTORS,
EXCEPT SCREW TERMINALS, SHALL BE OF THE ANTI-TURN SOLDERLESS TYPE
AND ALL SHALL BE SUITABLE FOR COPPER WIRE OF THE SIZES INDICATED
ON THE DRAWINGS. INTERIORS SHALL BE SO DESIGNED THAT SWITCHING AND
PROTECTIVE DEVICES CAN BE REPLACED WITHOUT DISTURBING ADJACENT
UNITS AND WITHOUT REMOVING THE MAIN BUS CONNECTORS AND SHALL BE SO
DESIGNED THAT CIRCUITS MAY BE CHANGED WITHOUT MACHINING, DRILLING
OR TAPPING. A NAMEPLATE SHALL BE PROVIDED LISTING PANEL TYPE, NUM-
BER OF PROTECTIVE AND SWITCHING DEVICES AND RATINGS. BUS BARS FOR
THE MAINS SHALL BE COPPER SIZED IN ACCORDANCE WITH UL STANDARDS.
UNLESS OTHERWISE NOTED, FULL-SIZE INSULATED NEUTRAL AND GROUND BUS
BARS SHALL BE INCLUDED. BUS BAR TAPS FOR PANELS WITH SINGLE POLE
BRANCHES SHALL BE ARRANGED FOR SEQUENCE PHASING OF THE BRANCH CIR-
CUIT DEVICES. BUSSING SHALL BE BRACED THROUGHOUT TO CONFORM TO
INDUSTRY STANDARD PRACTICE GOVERNING SHORT CIRCUIT STRESSES IN
PANELBOARDS. BRACING SHALL BE EQUIVALENT TO, OR COMPATIBLE WITH,
THE RATE INTERRUPTING CAPACITY OF THE SMALLEST OVERCURRENT DEVICE
IN THAT PANELBOARD. BOXES SHALL BE MADE FROM UNPAINTED GALVANIZED
CODE GAUGE STEEL HAVING MULTIPLE KNOCKOUTS EXCEPT WHERE NOTED.
BOXES SHALL BE OF SUFFICIENT SIZE TO PROVIDE A MINIMUM GUTTER
SPACE OF 4" ON ALL SIDES, AND TO HAVE A MINIMUM WIDTH OF 20".
WHERE FEEDER CABLES SUPPLYING THE MAINS OF A PANEL ARE CARRIED
THROUGH ITS BOX TO SUPPLY OTHER ELECTRICAL EQUIPMENT, THE BOX
SHALL BE SO SIZED AS TO INCLUDE THIS WIRING SPACE. THIS WIRING
SPACE SHALL BE IN ADDITION TO THE MINIMUM GUTTER SPACE SPECIFIED
ABOVE AND THE LIMITING WIDTH MAY BE INCREASED ACCORDINGLY. AT
SPACE SHALL BE IN ADDITION TO THE MINIMUM GUTTER SPACE SPECIFIED
ABOVE AND THE LIMITING WIDTH MAY BE INCREASED ACCORDINGLY. AT
LEAST 4 INTERIOR MOUNTING STUDS SHALL BE PROVIDED. BOX IDENTI-
FICATION NUMBER SHALL BE ON BOX.
HINGED DOORS COVERING ALL SWITCHING DEVICE HANDLES SHALL BE IN-
CLUDED IN ALL PANEL TRIMS, AND SHALL NOT UNCOVER ANY LIVE PARTS
IN MAKING SWITCHING DEVICE HANDLES ACCESSIBLE. DOORS SHALL HAVE
SEMI-FLUSH-TYPE CYLINDER LOCK AND CATCH, EXCEPT THAT DOORS OVER
48" IN HEIGHT SHALL HAVE A VAULT HANDLE AND 3-POINT CATCH, COM-
PLETE WITH LOCK, ARRANGED TO FASTEN DOOR AT TOP,BOTTOM AND CENTER.
DOOR HINGES SHALL BE CONCEALED. ALL LOCKS SHALL BE KEYED ALIKE.
A DIRECTORY FRAME AND DIRECTORY CARD HAVING A TRANSPARENT PLASTIC
COVER SHALL BE FURNISHED ON THE INSIDE FACE OF EACH DOOR. THE
TRIMS SHALL BE FABRICATED FROM CODE GAUGE SHEET STEEL. ALL EXTERIOR
AND INTERIOR STEEL SURFACES OF THE PANELBOARD TRIM SHALL BE PRO-
PERLY CLEANED AND FINISHED WITH GREY ANSI-61 PAINT OVER A RUST-
INHIBITING PHOSPHATIZED COATING. TRIMS SHALL HAVE THE SAME WIDTH
AND HEIGHT AS THE BOX. TRIMS SHALL BE MOUNTABLE BY A SCREWDRIVER
WITHOUT THE NEED FOR SPECIAL TOOLS. ALL JUNCTION AND PULL BOXES
SHALL BE FABRICATED OF GALVANIZED STEEL, OR MOLDED PVC (EXTERIOR
USE ONLY). THE DIMENSIONS OF THE BOX SHALL BE SIZED TO ALLOW
ADEQUATE WORKING SPACE AND CABLE CAPACITY. ALL JUNCTION BOXES
SHALL FORM A COMPLETE ENCLOSURE AND SHALL BE RAINTIGHT AND OF
ADEQUATE STRENGTH. THE TERMINALS USED SHALL BE CONSTRUCTED OF
A NON-CORROSIVE MATERIAL. A REMOVABLE FRONT COVER SHALL BE PRO-
VIDED, AND INSTALLED SUCH THAT WHEN CLOSED, IT WILL BE SECURED
SUFFICIENTLY TO PREVENT ACCIDENTAL OPENING.
CABLE AND CONDUIT ENTRANCES AND EXITS SHALL BE MADE WITH APPRO-
PRIATE CONNECTORS IN SUCH A MANNER THAT RAINTIGHT INTEGRITY IS
RETAINED.
ALL PANELBOARDS AFFECTED BY WORK SHALL HAVE ALL PANEL DIRECTORIES
UPDATED IN ACCORDANCE WITH UFC 3-520-01.
TESTING
1. METHODS: THE SUB-CONTRACTOR SHALL VERIFY THE FOLLOWING IN THE
PRESENCE OF THE INSPECTOR.
A. THAT ALL LIGHTING POWER AND CONTROL CIRCUITS ARE
CONTINUOUS AND FREE FROM SHORT CIRCUITS.
B. THAT ALL CIRCUITS ARE FREE FROM UNSPECIFIED GROUNDS.
C. THAT THE INSULATION RESISTANCE TO GROUND OF ALL NON-
GROUNDED SERIES CIRCUITS IS NOT LESS THAN 50 MEGOHMS.
D. THAT THE INSULATION RESISTANCE TO GROUND OF ALL NON-
GROUNDED CONDUCTORS OF MULTIPLE CIRCUITS IS NOT LESS
THAN 50 MEGOHMS.
E. THAT ALL CIRCUITS ARE PROPERLY CONNECTED IN ACCORDANCE
WITH APPLICABLE WIRING DIAGRAMS.
F. THAT ALL CIRCUITS ARE OPERABLE. TESTS SHALL BE CONDUC-
TED THAT INCLUDE OPERATING EACH CONTROL NOT LESS THAN
10 TIMES AND THE CONTINUOUS OPERATION OF EACH LIGHTING
AND POWER CIRCUIT FOR NOT LESS THAN 2 HOURS.
SECTION 26 05 00 - COMMON WORK RESULTS FOR ELECTRICAL
1. ALL ELECTRICAL WORK AND MATERIALS SHALL BE IN COMPLIANCE WITH ALL
GOVERNING CODES AND STANDARDS. THIS SHALL INCLUDE BUT NOT BE
LIMITED TO THE FOLLOWING.
A. NFPA 70 NATIONAL ELECTRICAL CODE (LATEST EDITION)
B. FLORIDA BUILDING CODE (LATEST EDITION)
C. NFPA 72 NATIONAL FIRE CODE (LATEST EDITION)
D. FLORIDA FIRE PREVENTION CODE (LATEST EDITION)
D. FLORIDA FIRE PREVENTION CODE (LATEST EDITION)
E. LOCAL REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION
F. UNIFIED FACILITIES CRITERIA (UFC) PROGRAM.
G. AIR FORCE REGULATIONS.
H. MACDILL AFB GENERAL GUIDELINES FOR FACILITY CONSTRUCTION AND
RENOVATION.
2. UTILIZE GOOD WORKMANSHIP FOR THE INSTALLATION OF ALL WORK. INSTALL
WORK LEVEL, PLUMB, AND TRUE WITH THE BUILDING STRUCTURE AND WALLS.
SECURE ALL WORK IN PLACE WITH SUPPORTS THAT ARE SUFFICIENT IN SIZE
AND QUANTITY TO PERMANENTLY SUPPORT THE WORK IN ACCORDANCE WITH
MANUFACTURERS RECOMMENDATIONS.
3. THE DEMOLITION OF EXISTING AND/OR THE STOCKING OF NEW BUILDING
MATERIALS SHALL NOT HINDER OR INTERFERE WITH EMERGENCY ACCESS TO
THE PROPERTY OR VICINITY THEREOF (INCLUDING FIRE LANES).
4. ALL MATERIALS SHALL BE LISTED BY A NATIONALLY RECOGNIZED TESTING
LABORATORY. (IE. UL, CSA, MET, ETC)
5. ALL MATERIALS SHALL BE NEW AND FREE FROM DEFECT, EXCEPT WHERE
SPECIFICALLY SHOWN TO REUSE EXISTING MATERIALS.
6. ALL WORK SHALL BE SUITABLE FOR THE ENVIRONMENT THAT IT IS INSTALLED.
7. COORDINATE THE INSTALLATION OF THE UTILITY TRANSFORMER WITH THE
APPROPRIATE POWER COMPANY. CONFIRM WITHIN 10 DAYS OF THE AWARD OF
CONTRACT THAT THE AVAILABLE FAULT CURRENT AT THE TRANSFORMER
SECONDARY BUSHINGS DOES NOT EXCEED THE DESIGNED FAULT CURRENT AT
THE SERVICE ENTRANCE EQUIPMENT. NOTIFY THE ENGINEER IMMEDIATELY IF
THE DESIGNED FAULT CURRENT IS EXCEEDED.
8. VISIT THE SITE OF THE PROPOSED PROJECT TO BECOME FAMILIAR WITH
CONDITIONS AND NATURE OF THE WORK PRIOR TO SUBMITTING BIDS. NOTIFY
THE ENGINEER OF DISCREPANCIES OR OMISSIONS FOR INTERPRETATION OR
DECISION PRIOR TO SUBMITTING BIDS. SUBMISSION OF A PROPOSAL WILL BE
EVIDENCE THAT SUCH FAMILIARIZATION HAS BEEN ATTAINED.
9. ANY DEMOLISHED ITEMS SHALL BE DISPOSED OF OR RECYCLED OFF SITE IN
ACCORDANCE WITH STATE STATUTES UNLESS NOTED SPECIFICALLY TO BE
TURNED OVER TO OWNER.
10. WHERE CONTRACTOR PROPOSES ALTERNATE SOLUTIONS, DIFFERENT ROUTINGS
OF CONDUIT, DIFFERENT LOCATIONS OF EQUIPMENT, ETC. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR ALL OF THE RAMIFICATIONS OF THE PROPOSED
CHANGE THAT ARE NOT INCLUDED IN HIS PROPOSAL, BUT BECOME APPARENT
AT A LATER DATE, AND SHALL BE RESPONSIBLE FOR ALL COST AND
CONSEQUENCES OF CORRECTING ANY AND ALL CONFLICTS, DEFICIENCIES OR
PROBLEMS THAT INCREASE COST, INCREASE CONSTRUCTION TIME OR CREATE
CODE VIOLATIONS.
11. INFORMATION SHOWN ON THE DRAWINGS AS TO THE LOCATION OF EXISTING
UTILITIES HAS BEEN PREPARED FROM THE MOST RELIABLE DATA AVAILABLE
TO THE ENGINEER. IT IS TO BE UNDERSTOOD THAT UNFORESEEN CONDITIONS
PROBABLY EXIST AND NEW WORK MAY NOT BE LOCATED EXACTLY AS SHOWN ON
THE DRAWINGS. COORDINATION WITH OTHER TRADES FOR LOCATION AND BURIAL
DEPTHS WILL BE REQUIRED AND ANY SUCH REQUIRED DEVIATIONS SHALL BE
CONSIDERED PART OF THIS SCOPE OF WORK. SITE UTILITY INFORMATION IS
NOT GUARANTEED, THEREFORE THE CONTRACTOR SHALL FIELD VERIFY THE
EXACT LOCATIONS AND DEPTHS OF EXISTING UTILITIES PRIOR TO BEGINNING
WORK. PROTECT ANY EXISTING UTILITIES TO REMAIN FROM DAMAGE DURING
THE COURSE OF CONSTRUCTION.
12. PROVIDE ALL LABOR, MATERIALS AND EQUIPMENT FOR A COMPLETE AND
OPERATING ELECTRICAL SYSTEM. THE PLANS AND SPECIFICATIONS ARE
INTENDED AS A GENERAL DESCRIPTION OF THE WORK TO BE PERFORMED. ALL
ITEMS NOT SPECIFICALLY MENTIONED OR SHOWN, BUT NECESSARY FOR THE
COMPLETION OF THE INSTALLATION, SHALL BE FURNISHED AND INSTALLED BY
THIS CONTRACTOR. THIS CONTRACTOR SHALL BECOME THOROUGHLY ACQUAINTED
WITH THE MECHANICAL, PLUMBING, ARCHITECTURAL, STRUCTURAL, CIVIL AND
ELECTRICAL PLANS BEFORE SUBMITTING BIDS. NO ADDITIONAL COMPENSATION
JH
F
EB
ELECTRICAL SPECIFICATIONS:
D at e D es cr ip tio n
D at e:
D ra w in g Fi le N am e:
D ra w n
By
M
AC
D
IL
L
AI
R F
O R
C E
BA
SE
, F
LO
R
ID
A
Sheet No.
D es ig ne d By
Ap pr ov ed
B y:
R ev ie w ed B y:
M ar k Ap pr
6T H
C
IV
IL
E
N G
IN
EE
R S
Q U
AD
R
O N
Facility I.D.
C
AD
D L ea de r:
IF
TH
IS
D
RA
W
IN
G
IS
LE
SS
TH
AN
" x
IT
IS
A
RE
DU
CE
D
SI
ZE
D
RA
W
IN
G.
D ec
5,
- 9
:1 7a m b y
E O
:\D R
AW
IN
G S\
Pr oj ec tN um be r\2 4-
\E -0
.d w g ofSheet
PR
O
JE
CT
N O
. N
VZ
R
D
EC
-4
CO
NV
ER
T
ED
C
EN
TE
R
TO
A
LS
B
JH
/ A
C M
F
IN
A L
A
P P
R O
V E
D F
O R
C O
N S
T R
U C
T
IO
N
E-001
E-
1.
dw g
EL
EC
TR
IC
AL
SP
EC
IF
IC
AT
IO
N S
J.
BA
SI
AG
A
J.
H
EN
R
Y
AutoCAD SHX Text
REV
AutoCAD SHX Text D
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text Y
AutoCAD SHX Text T
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text R
AutoCAD SHX Text I
A
WITH THE MECHANICAL, PLUMBING, ARCHITECTURAL, STRUCTURAL, CIVIL AND
ELECTRICAL PLANS BEFORE SUBMITTING BIDS. NO ADDITIONAL COMPENSATION
WILL BE ALLOWED DUE TO CONTRACTOR'S FAILURE TO BECOME FAMILIAR WITH
THE PROJECT.
13. PROVIDE TEMPORARY LIGHTING AND POWER FOR THE PROJECT IN ACCORDANCE
WITH OSHA STANDARDS. ADEQUATE DISTRIBUTION AND OUTLETS SHALL BE
PROVIDED TO POWER ALL CONTRACTORS 120V SINGLE PHASE TOOLS WITHIN
100' OF ALL WORK SPACES.
14. ALL SYSTEMS SHALL BE TESTED FOR PERFORMANCE VERIFICATION IN THE
PRESENCE OF THE INSPECTOR, AT THE COMPLETION OF THE PROJECT. ALLOW 4
HOURS FOR TRAINING GOVERNMENT PERSONNEL ON ALL SYSTEMS.
15. THE CONTRACTOR SHALL THOROUGHLY CLEAN ALL EQUIPMENT TO BE
COMPLETELY FREE OF INTERNAL DEBRIS, EXTERIOR PAINT/MARKS, AND DIRT.
16. CONTRACTOR PERFORMING ANY PART OF THIS SCOPE OF WORK SHALL BE A
STATE CERTIFIED (TYPE E.C. LICENSE) ELECTRICAL CONTRACTOR. PROVIDE
FIELD SUPERINTENDENT WHO HAS A MINIMUM OF FOUR (4) YEARS PREVIOUS
SUCCESSFUL EXPERIENCE ON PROJECTS OF COMPARABLE SIZE AND COMPLEXITY.
SUPERINTENDENT SHALL BE ON THE SITE AT ALL TIMES DURING CONSTRUCTION
AND MUST HAVE AN ACTIVE JOURNEYMAN OR MASTER ELECTRICAL LICENSE FOR
THE JURISDICTION WHERE THE WORK IS BEING PERFORMED.
17. WORK IS IN CONNECTION WITH EXISTING BUILDINGS WHICH MUST REMAIN IN
OPERATION WHILE WORK IS BEING PERFORMED. WORK SHALL BE IN
ACCORDANCE WITH THE SCHEDULE REQUIRED BY THE CONTRACT. SCHEDULE
WORK FOR MINIMUM OUTAGES ACCEPTABLE TO USER. NOTIFY INSPECTOR
72 HOURS IN ADVANCE OF ANY SHUT-DOWN OF EXISTING SYSTEMS. PROTECT
EXISTING BUILDINGS AND EQUIPMENT DURING CONSTRUCTION.
18. THE USE OF ANY PROCESS INVOLVING ASBESTOS OR PCB, AND THE
INSTALLATION OF ANY PRODUCT, INSULATION, COMPOUND OF MATERIAL
CONTAINING OR INCORPORATING ASBESTOS OR PCB, IS PROHIBITED. THE
REQUIREMENTS OF THIS SPECIFICATION FOR COMPLETE AND OPERATING
ELECTRICAL SYSTEMS SHALL BE MET WITHOUT THE USE OF ASBESTOS OR PCB.
19. CONTRACTOR IS TO PROVIDE THE GOVERNMENT WITH AS-BUILT DRAWINGS OF
THE SINGLE LINE DIAGRAM OF THE ELECTRICAL DISTRIBUTION SYSTEM AND
FLOOR PLANS INDICATING LOCATIONS OF EQUIPMENT SERVED.ALSO, PROVIDE
OPERATIONS AND MAINTENANCE MANUALS FOR EQUIPMENT REQUIRING
MAINTENANCE AND THE CONTACT INFORMATION FOR A QUALIFIED SERVICE
AGENCY.
20. EXTERIOR EQUIPMENT AND COMPONENT ITEMS, INCLUDING BUT NOT LIMITED
TO FERROUS METAL LUMINARIES NOT HOT-DIP GALVANIZED OR PORCELAIN
ENAMEL FINISHED, SHALL BE PROVIDED WITH CORROSION-RESISTANT
FINISHES WHICH SHALL WITHSTAND 2000 HOURS OF EXPOSURE TO THE
SALT SPRAY TEST SPECIFIED IN AAMA 2604 WITHOUT LOSS OF PAINT
OR RELEASE OF ADHESION OF THE PAINT PRIMER COAT TO THE METAL
SURFACE FOR ALL LIGHTING FIXTURES AND POLES, SERVICE ENTRANCE
EQUIPMENT AND GENERATOR EQUIPMENT, U.O.N.. THE SCRIBED TEST
MARK AND TEST EVALUATION SHALL BE IN ACCORDANCE WITH
ASTM D 1654 WITH A RATING OF NOT LESS THAN 7 IN ACCORDANCE
WITH TABLE 1, (PROCEDURE A). CUT EDGES OR OTHERWISE DAMAGED
SURFACES OF HOT-DIP GALVANIZED SHEET STEEL OR MILL GALVANIZED
SHEET STEEL SHALL BE COATED WITH A ZINC RICH PAINT CONFORMING
TO THE MANUFACTURER'S STANDARDS.
SECTION 26 05 19 - LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES
1. ALL POWER CONDUCTORS SHALL BE COPPER WITH DUAL RATED THHN/THWN-2 600V
INSULATION.
2. PROVIDE ALL FEEDERS WITH CONDUCTORS SIZED SUCH THAT THEY DO NOT EXCEED
2% VOLTAGE DROP PER FBC ENERGY CONSERVATION 505.7.3.1.
3. PROVIDE ALL BRANCH CIRCUITS WITH CONDUCTORS SIZED SUCH THAT THEY DO
NOT EXCEED 3% VOLTAGE DROP PER FBC ENERGY CONSERVATION 505.7.3.2.THE
FOLLOWING METHOD SHALL BE USED FOR TYPICAL BRANCH CIRCUITS:
3.1. ALL 120V, 20A BRANCH CIRCUIT CONDUCTORS LESS THAN 60' IN LENGTH
FROM THE CIRCUIT BREAKER TO ANY DEVICE SHALL UTILIZE #12 MINIMUM
3.1. ALL 120V, 20A BRANCH CIRCUIT CONDUCTORS LESS THAN 60' IN LENGTH
FROM THE CIRCUIT BREAKER TO ANY DEVICE SHALL UTILIZE #12 MINIMUM
THROUGHOUT AND #12 GROUND.
3.2. ALL 120V, 20A BRANCH CIRCUIT CONDUCTORS WHERE THE LENGTH IS 60'
TO 120' FROM THE CIRCUIT BREAKER TO ANY DEVICE SHALL UTILIZE #10
MINIMUM THROUGHOUT AND #10 GROUND, UNLESS OTHERWISE NOTED.
3.3. ALL 120V, 20A BRANCH CIRCUIT CONDUCTORS WHERE THE LENGTH IS 120'
to 240' FROM THE CIRCUIT BREAKER TO ANY DEVICE SHALL BE # 8
CONDUCTOR MINIMUM THROUGHOUT AND #8 GROUND, UNLESS OTHERWISE
NOTED.
3.4. ALL 120V, 20A BRANCH CIRCUIT CONDUCTORS WHERE THE LENGTH IS
GREATER THAN 240' FROM THE CIRCUIT BREAKER TO ANY DEVICE SHALL
BE # 6 CONDUCTOR MINIMUM THROUGHOUT AND #6 GROUND, UNLESS
OTHERWISE NOTED.
3.5. ALL 277V, 20A BRANCH CIRCUIT CONDUCTORS LESS THAN 140' IN LENGTH
FROM THE CIRCUIT BREAKER TO ANY DEVICE SHALL UTILIZE # 12
CONDUCTOR MINIMUM THROUGHOUT AND #12 GROUND, UNLESS OTHERWISE
NOTED.
3.6. ALL 277V, 20A BRANCH CIRCUIT CONDUCTORS WHERE THE LENGTH IS 140'
to 220' FROM THE CIRCUIT BREAKER TO ANY DEVICE SHALL BE # 10
CONDUCTOR MINIMUM THROUGHOUT AND #10 GROUND, UNLESS OTHERWISE
NOTED.
3.7. ALL 277, 20A BRANCH CIRCUIT CONDUCTORS WHERE THE LENGTH IS 220'
to 340' FROM THE CIRCUIT BREAKER TO ANY DEVICE SHALL BE # 8
CONDUCTOR MINIMUM THROUGHOUT AND #8 GROUND, UNLESS OTHERWISE
NOTED.
3.8. ALL 277V, 20A BRANCH CIRCUIT CONDUCTORS WHERE THE LENGTH IS
GREATER THAN 340' FROM THE CIRCUIT BREAKER TO ANY DEVICE SHALL
UTILIZE # 6 CONDUCTOR MINIMUM THROUGHOUT AND #6 GROUND, UNLESS
OTHERWISE NOTED.
4. PROVIDE DEDICATED NEUTRAL CONDUCTOR FOR ALL DIMMER CIRCUITS FROM THE
LOAD BACK TO THE DIMMER.
5. DO NOT PULL CONDUCTORS INTO CONDUIT UNTIL CONDUIT IS COMPLETE FROM
END TO END AND ALL WORK, WHICH MAY CAUSE DAMAGE TO CONDUCTORS, IS
COMPLETED.
6. USE PULLING MEANS THAT WILL NOT DAMAGE CABLES OR RACEWAY. USE
MANUFACTURERS APPROVED PULLING COMPOUND OR LUBRICANT WHERE
NECESSARY. DO NOT EXCEED THE MANUFACTURER'S RECOMMENDED MAXIMUM
PULLING TENSIONS AND SIDEWALL PRESSURE VALUES.
7. TIGHTEN ELECTRICAL CONNECTORS AND TERMINALS ACCORDING TO
MANUFACTURER'S PUBLISHED TORQUE-TIGHTENING VALUES. IF MANUFACTURER'S
TORQUE VALUES ARE NOT INDICATED, USE THOSE SPECIFIED IN UL 486A AND
UL 486B.
8. NO SPLICES SHALL BE MADE IN JUNCTION BOX, AND OUTLET BOXES (WIRE NO.
6 AND LARGER) WITHOUT WRITTEN ACCEPTANCE OF ENGINEER.
9. ALL INTERIOR POWER AND LIGHTING TAPS AND SPLICES IN NO. 8 OR SMALLER
SHALL BE FASTENED TOGETHER BY MEANS OF "SPRING TYPE" CONNECTORS.
ALL TAPS AND SPLICES IN WIRE LARGER THAN NO. 8 SHALL BE MADE WITH
COMPRESSION TYPE CONNECTORS AND TAPED TO PROVIDE INSULATION EQUAL TO
WIRE.
10. ALL EXTERIOR BELOW GRADE POWER AND LIGHTING TAPS AND SPLICES SHALL BE
MADE WITH COMPRESSION TYPE CONNECTORS AND COVERED WITH RAYCHEM
HEAVYWALL CABLE SLEEVES (TYPE CRSM-CT, WCSM OR MCK) WITH TYPE "S"
SEALANT COATING WITH SLEEVE KITS AS PER MANUFACTURER'S INSTALLATION
INSTRUCTIONS OR BE TERMINATED/CONNECTED TO IN ABOVE GRADE TERMINAL
BOXES SUITABLE FOR SUCH EXTERIOR USE.
SECTION 26 05 26 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS
1. PROVIDE CONTINUOUS GROUNDING SYSTEM IN ACCORDANCE WITH NEC 250 AND
1. PROVIDE CONTINUOUS GROUNDING SYSTEM IN ACCORDANCE WITH NEC 250 AND
AS INDICATED.
2. PROVIDE COPPER EQUIPMENT GROUNDING CONDUCTOR IN ALL CONDUITS. SIZE
GROUNDING CONDUCTOR IN ACCORDANCE WITH NEC 250.
3. PROVIDE AT LEAST (3) 20' X 3/4" COPPER GROUND RODS SPACED 20' APART
TO FORM A DELTA FOR THE GROUNDING ELECTRODE. TEST GROUND RESISTANCE
OF THE DELTA RODS TO BE 5 OHM OR LESS WITHOUT CONNECTION TO THE
REMAINDER OF THE GROUNDING ELECTRODE. IF RESISTANCE IS GREATER THAN
5 OHMS, DRIVE ADDITIONAL GROUND RODS TO ACHIEVE 5 OHMS OR LESS.
4. EFFECTIVELY GROUNDED METAL WATER PIPING, STRUCTURAL STEEL, UFER
GROUNDS, COUNTERPOISE AND GROUND RODS SHALL BE CONNECTED TO FORM
THE GROUNDING ELECTRODE IN ACCORDANCE WITH NEC 250. PROVIDE THE
GROUNDING ELECTRODE CONDUCTOR IN ACCORDANCE WITH NEC 250.
5. EQUIPMENT GROUND CONDUCTORS SHALL BE INSULATED AND HAVE A
CONTINUOUS OUTER FINISH THAT IS GREEN. EQUIPMENT GROUNDING
CONDUCTORS LARGER THAN #6AWG SHALL BE PERMITTED TO BE PERMANENTLY
IDENTIFIED AT ONLY THOSE POINTS WHERE THE CONDUCTOR IS ACCESSIBLE.
6. GROUND BARS SHALL BE COPPER OF THE SIZE AND DESCRIPTION AS SHOWN
ON THE DRAWINGS. IF NOT SIZED ON DRAWINGS, BUS BAR SHALL BE MINIMUM
1/4" X 4" BUS GRADE COPPER, SPACED FROM WALL ON INSULATING 2"
POLYESTER MOLDED INSULATOR STANDOFF/SUPPORTS, AND BE 12" OR GREATER
MINIMUM OVERALL LENGTH, ALLOWING 2" LENGTH PER LUG CONNECTED THERETO.
INCREASE OVERALL LENGTH AS REQUIRED TO FACILITATE ALL LUGS REQUIRED
WHILE MAINTAINING 2" SPACING. SIZE OF BUS BAR USED IN MAIN
ELECTRICAL ROOM SHALL BE SIMILAR EXCEPT MINIMUM OF 4" HIGH AND 24"
LONG.
7. ALL CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC WELDED UNLESS
OTHERWISE NOTED HEREIN. ALL CONNECTIONS ABOVE GRADE AND IN ACCESSIBLE
LOCATIONS MAY BE BY EXOTHERMIC WELDING OR BY BRAISING OR CLAMPING WITH
DEVICES UL LISTED AS SUITABLE FOR USE EXCEPT IN LOCATIONS WHERE
EXOTHERMIC WELDING IS SPECIFICALLY SPECIFIED IN THESE SPECIFICATIONS
OR CALLED FOR ON DRAWINGS.
8. BOND LIGHTNING PROTECTION SYSTEM GROUNDS TO ELECTRICAL SERVICE SYSTEM
GROUND, ALL PIPING ENTERING OR LEAVING ALL BUILDINGS, AND COUNTERPOISE
SYSTEM GROUND WHERE PROVIDED.
9. ONE 30 FT. GROUND ROD ELECTRODE SHALL BE DRIVEN VERTICALLY TO A
MINIMUM DEPTH OF 30 FT. PLUS 1 FT. BELOW GRADE IN EACH MANHOLE,
HANDHOLE OR PULLBOX (IN GROUND). BOND ROD TO METAL COVER WITH
APPROPRIATE LUG AND BARE CU CONDUCTOR.
10. INSTALL GROUNDING BUS IN ALL EXISTING PANELBOARDS OF REMODELED AREAS,
FOR CONNECTION OF NEW GROUNDING CONDUCTORS, CONNECTED TO BUILDING
GROUNDING ELECTRODE.
SECTION 26 05 33 - RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS
1. ALL WIRING SHALL BE INSTALLED IN ADEQUATELY SIZED CONDUIT UNLESS
OTHERWISE NOTED. USE 3/4" MINIMUM FOR ALL CONDUITS.
2. CONCEAL ALL CONDUITS IN WALLS, ABOVE FINISHED CEILING, IN FLOOR
SLABS AND UNDERGROUND EXCEPT IN MECHANICAL AND ELECTRICAL ROOMS.
3. CREATE ALL OPENINGS FOR CONDUIT PENETRATIONS THROUGH WALLS, SLABS,
AND ROOF OPENINGS. SEAL ALL PENETRATIONS APPROPRIATELY. PROVIDE
PROPER FIRE PENETRATION SEALING OF ALL OPENINGS THROUGH FIRE RATED
WALLS, CEILING, AND FLOORS IN ACCORDANCE WITH THE APPROPRIATE UL
LISTED FIRE PENETRATION DETAILS.
4. COORDINATE THE INSTALLATION OF ALL CONDUITS WITH STRUCTURAL,
MECHANICAL, PLUMBING, AND OTHER CONTRACTORS PRIOR TO INSTALLATION.
5. USE SCHEDULE 40 PVC FOR ALL EXTERIOR BELOW GRADE WORK. USE GRC FOR
EXPOSED EXTERIOR WORK. SWEEPS SHALL BE UTILIZED FOR ALL UTILITY
CONDUITS AND AS NEEDED BY THE CONTRACTOR FOR PULLING PURPOSES.
6. EMT SHALL BE USED FOR ALL INTERIOR WORK EXCEPT USE GRC WHERE CONDUIT
JH
F
EB
ELECTRICAL SPECIFICATIONS (con't.):
D at e D es cr ip tio n
D at e:
D ra w in g Fi le N am e:
D ra w n
By
M
AC
D
IL
L
AI
R F
O R
C E
BA
SE
, F
LO
R
ID
A
Sheet No.
D es ig ne d By
Ap pr ov ed
B y:
R ev ie w ed B y:
M ar k Ap pr
6T H
C
IV
IL
E
N G
IN
EE
R S
Q U
AD
R
O N
Facility I.D.
C
AD
D L ea de r:
IF
TH
IS
D
RA
W
IN
G
IS
LE
SS
TH
AN
" x
IT
IS
A
RE
DU
CE
D
SI
ZE
D
RA
W
IN
G.
D ec
5,
- 9
:1 7a m b y
E O
:\D R
AW
IN
G S\
Pr oj ec tN um be r\2 4-
\E -0
.d w g ofSheet
PR
O
JE
CT
N O
. N
VZ
R
D
EC
-4
CO
NV
ER
T
ED
C
EN
TE
R
TO
A
LS
B
JH
/ A
C M
F
IN
A L
A
P P
R O
V E
D F
O R
C O
N S
T R
U C
T
IO
N
E-002
E-
2.
dw g
EL
EC
TR
IC
AL
SP
EC
IF
IC
AT
IO
N S
J.
BA
SI
AG
A
J.
H
EN
R
Y
AutoCAD SHX Text
REV
AutoCAD SHX Text D
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text Y
AutoCAD SHX Text T
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text R
AutoCAD SHX Text I
6. EMT SHALL BE USED FOR ALL INTERIOR WORK EXCEPT USE GRC WHERE CONDUIT
IS SUBJECT TO DAMAGE. STEEL COMPRESSION FITTINGS SHALL BE USED IN
DRY LOCATIONS. STEEL COMPRESSION INSULATED THROAT FITTINGS SHALL
BE USED IN WET OR DAMP LOCATIONS.
7. USE FLEXIBLE METAL CONDUIT IN DRY LOCATIONS AND LIQUIDTITE FLEXIBLE
METAL CONDUIT IN DAMP OR WET LOCATIONS FOR THE FINAL CONNECTION OF
MOTORS, TRANSFORMERS AND OTHER EQUIPMENT WITH VIBRATION.
8. MC CABLE MAY ONLY BE USED FOR LIGHTING AND POWER BRANCH CIRCUITS 20A
OR SMALLER. MC CABLE SHALL NOT BE USED FOR HOMERUNS (FROM PANEL TO
FIRST DEVICE, FIXTURE, OR EQUIPMENT) (PULL BOXES AND JUNCTION BOXES
ARE NOT CONSIDERED DEVICES, FIXTURES, OR EQUIPMENT), MC CABLE SHALL
NOT BE INSTALLED IN LENGTHS EXCEEDING 6' BETWEEN DEVICES OR WHERE
IT IS EXPOSED, UNLESS OTHERWISE NOTED.
9. ALL UNUSED OR SPARE CONDUITS SHALL BE CAPPED AND LABELED (OPPOSITE
END LOCATION AND USE) AT BOTH ENDS. PROVIDE WITH A PULL STRING.
10. ALL CONDUIT AND CABLE SUPPORTS SHALL BE LISTED AND LABELED FOR THEIR
INTENDED INSTALLATION. TIE WIRE SHALL NOT BE UTILIZED FOR SUPPORT
11. PROVIDE OUTLET BOXES THAT ARE 4" SQUARE STEEL WITH PLASTER RING SIZED
IN ACCORDANCE WITH THE NEC FOR DRY LOCATIONS. USE MINIMUM 1 1/2" DEEP
BOXES. COORDINATE THE APPROPRIATE RING TYPE WITH THE DEVICE OR FIXTURE
TO BE INSTALLED.
12. PROVIDE OUTLET BOXES THAT ARE CAST ALUMINUM WITH THREADED HUBS FOR
EXPOSED DAMP OR WET LOCATIONS.
13. USE NEMA 1 RATED BOXES FOR PULL BOXES IN DRY LOCATIONS. USE NEMA 4X
STAINLESS STEEL RATED BOXES FOR ALL EXTERIOR ABOVE GROUND PULL BOXES.
USE STAINLESS STEEL OR PVC BOXES IF EXPOSED TO CORROSIVE ENVIRONMENT.
14. EXTERIOR IN GROUND BOXES SHALL BE NEMA 6 RATED FOR UNDERWATER
SUBMERSION. PROVIDE APPROPRIATE CONCRETE RING AND COVER OVER NEMA 6
BOXES FOR ACCESS AND MECHANICAL PROTECTION. PROVIDE TRAFFIC RATED
COVERS FOR CONCRETE RINGS IN ALL AREAS, T15 RATING UNLESS OTHERWISE
NOTED.
15. FLOOR BOXES FOR SLAB ON GRADE SHALL BE PVC WITH BRASS COVERS AND
RINGS. FLOOR BOXES IN ALL OTHER RATED FLOORS SHALL BE DEEP CAST STEEL
WITH BRASS COVERS AND RINGS. UTILIZE POKE THRU BOXES WITH BRASS COVERS
FOR USE IN EXISTING FIRE RATED FLOORS.
16. COORDINATE ALL POWER AND SYSTEM DEVICE BOX LOCATIONS SO THAT THEY ARE
LOCATED AT THE SAME HEIGHT WHEN LOCATED ADJACENT TO EACH OTHER.
17. THIS CONTRACTOR SHALL GET FINAL APPROVAL FROM THE ARCHITECT FOR THE
LOCATIONS OF ALL EXTERIOR LIGHT FIXTURES, POWER OUTLETS, AND SYSTEM
DEVICES PRIOR TO THE INSTALLATION OF BOXES AND CONDUIT.
18. ITEMS LOCATED IN TILE SURFACES SHALL BE INSTALLED AS CLOSE AS POSSIBLE
TO THE DIMENSIONS GIVEN AND SHALL BE HORIZONTALLY AND VERTICALLY
CENTERED AND ALIGNED WITH THE TILE JOINTS.
19. LOCATE CEILING MOUNTED ITEMS AS SHOWN ON THE ARCHITECTURAL REFLECTED
CEILING PLANS. WHERE ITEMS ARE NOT SHOWN ON THE REFLECTED CEILING
PLAN, CONSULT THE ARCHITECT AND LOCATE ACCORDINGLY. IF PHOTOMETRICS
HAVE BEEN PERFORMED, LOCATE FIXTURES ACCORDING TO PHOTOMETRIC PLANS.
20. WHERE INSTALLATION ABOVE COUNTER IS INDICATED, INSTALL ITEM 1" FROM
THE BOTTOM OF THE BOX OR ITEM TO THE TOP OF THE COUNTER (OR
BACKSPLASH IF SO EQUIPPED).
21. INSTALL FIXTURE BOXES ABOVE DOORS A MINIMUM OF 1" FROM THE BOTTOM OF
THE BOX OR FIXTURE TO THE TOP OF THE DOOR FRAME. PRIOR TO BOX
INSTALLATION, VERIFY THAT THERE IS SUFFICIENT WALL SPACE ABOVE THE
DOOR IS AVAILABLE FOR THE ITEM TO BE INSTALLED.
22. INSTALL LIGHTING FIXTURE BOXES SHOWN WALL MOUNTED ABOVE MIRRORS
CENTERED WITH THE MIRROR AND 1" FROM THE BOTTOM OF THE BOX OR
FIXTURE TO THE TOP OF THE MIRROR.
FIXTURE TO THE TOP OF THE MIRROR.
23. THE CONTRACTOR SHALL VERIFY THE EXACT DIRECTION OF ALL DOOR SWINGS
PRIOR TO THE ROUGH IN OF BOXES MOUNTED IN WALLS.
SECTION 26 05 53 - IDENTIFICATION FOR ELECTRICAL SYSTEMS
1. PROVIDE ENGRAVED LABELS FOR ALL LOADCENTERS, PANELBOARDS,
DISTRIBUTION PANELBOARDS, SWITCHBOARDS, SWITCHBOARD/DISTRIBUTION
PANEL MOUNTED CIRCUIT BREAKERS, DISCONNECT SWITCHES AND TRANSFORMERS
THAT IDENTIFY THE ITEM OR LOAD SERVED, VOLTAGE, AMPERAGE, AVAILABLE
FAULT CURRENT (AIC) AND WHERE IT ORIGINATES. SCREWS SHALL BE USED
TO ATTACH THE LABELS (DO NOT USE TAPE OR ADHESIVE). FIRST LINE SHALL
HAVE WHITE 3/8" LETTERS AND ALL OTHER LINES SHALL BE 1/4" LETTERS.
LABELS SHALL BE BLACK FOR "NORMAL POWER" AND RED FOR "EMERGENCY POWER".
2. TYPED CIRCUIT DIRECTORIES SHALL BE PROVIDED FOR EACH LOADCENTER OR
PANELBOARD INDICATING THE LOAD SERVED AND ROOM IDENTIFICATION.
3. LABEL EACH JUNCTION BOX WITH INDELIBLE MARKER AS TO THE SYSTEM
WITHIN OR CIRCUIT NUMBERS CONTAINED WITHIN.
4. POWER CONDUCTORS SHALL BE LABELED WITH VINYL OR VINYL-CLOTH, SELF
ADHESIVE, WRAPAROUND TYPE LABELS WITH PREPRINTED NUMBERS AND LETTERS
TO INDICATE THE PANEL AND CIRCUIT NUMBER OF EACH CONDUCTOR.
5. PERMANENT, BRIGHT COLORED, CONTINUOUS PRINTED, VINYL UNDERGROUND
WARNING TAPE WITH PRINTED LEGEND THAT INDICATES THE TYPE OF
UNDERGROUND LINE SHALL BE INSTALLED OVER ALL UNDERGROUND CONDUITS.
6. GROUNDED CONDUCTORS #6 AWG AND SMALLER SHALL BE IDENTIFIED BY A
CONTINUOUS WHITE OUTER FINISH FOR 240 OR 208 V SYSTEMS AND SHALL BE
IDENTIFIED BY A CONTINUOUS GRAY OUTER FINISH FOR 480V SYSTEMS. THIS
IDENTIFICATION SHALL BE PERMANENTLY POSTED AT EACH BRANCH CIRCUIT
PANELBOARD OR DISTRIBUTION EQUIPMENT.
7. GROUNDED CONDUCTORS LARGER THAN #6 AWG SHALL BE IDENTIFIED AT THE
TIME OF INSTALLATION BY A DISTINCTIVE WHITE MARKING AT ITS
TERMINATION FOR 240v OR 208v SYSTEMS AND SHALL BE INDENTIFIED BY A DISTINCTIVE GRAY MARKING AT ITS TERMINATION FOR 480v SYSTEMS. THIS
MARKING SHALL ENCIRCLE THE CONDUCTOR OR INSULATION.
8. THE FOLLOWING COLOR CODING SHALL BE UTILIZED FOR ALL CURRENT
CARRYING CONDUCTORS. CONTINUOUS COLOR CODED INSULATION SHALL BE
BLACK, RED, BLUE FOR 240V OR 208 V SYSTEMS AND BROWN, ORANGE,
YELLOW FOR 480V SYSTEMS. 1" WIDE COLORED TAPE ENCIRCLING THE
CONDUCTOR EVERY 2" FOR THE ENTIRE EXPOSED CONDUCTOR MAY BE
UTILIZED FOR COLOR CODING CONDUCTORS LARGER THAN #6 AT EACH
ACCESSIBLE POINT AND AT EACH TERMINATION POINT IN LIEU OF
CONTINUOUS COLOR CODING.
SECTION 26 22 00 - TRANSFORMERS
1. FACTORY ASSEMBLED, DRY TYPE, CONTINUOUS COPPER WINDINGS, 220DEG C
INSULATION, VENTILATED WITH A MAXIMUM OF 150 DEG C RISE ABOVE
AMBIENT. PROVIDE RAINSHIELD FOR TRANSFORMERS IN WET LOCATIONS.
COMPLY WITH NEMA ST 20 STANDARD SOUND LEVELS AFTER INSTALLATION.
2. PROVIDE NEOPRENE OR SPRING TYPE ISOLATION PADS UNDER TRANSFORMER
FOR VIBRATION ISOLATION. MOUNT TRANSFORMER ON A 4" HIGH REINFORCED
CONCRETE BASE THAT IS MINIMUM OF 4" LARGER THAN THE TRANSFORMER ON
ALL SIDES.
3. PROVIDE K-RATED TRANSFORMERS OF THE TYPE AS INDICATED ON THE
DRAWINGS.
4. PROVIDE CLEARANCE FOR COOLING AS REQUIRED BY TRANSFORMER
MANUFACTURER.
SECTION 26 27 26 - WIRING DEVICES
1. THE COLOR OF WIRING DEVICES SHALL BE SELECTED BY THE ARCHITECT FROM
IVORY, WHITE, BLACK, BROWN, OR GRAY.
2. LIGHT SWITCHES SHALL BE 20A, 120/277V, SPECIFICATION GRADE, TOGGLE.
2. LIGHT SWITCHES SHALL BE 20A, 120/277V, SPECIFICATION GRADE, TOGGLE.
PROVIDE SINGLE POLE, DOUBLE POLE, 3 WAY, OR 4 WAY AS INDICATED.
3. GENERAL USE RECEPTACLES SHALL BE 20A, 120V, SPECIFICATION GRADE,
HEAVY DUTY, N5-20R.
4. GROUND FAULT INTERRUPTING RECEPTACLES SHALL BE 20A, 120V, HEAVY
DUTY, SPECIFICATION GRADE, N5-20R.
5. PROVIDE HIGH IMPACT THERMOPLASTIC 1MM THICK WALL PLATES FOR ALL
DEVICES. PROVIDE A SINGLE PLATE FOR MULTIPLE GANG MOUNTED DEVICES.
6. IN WET LOCATIONS PROVIDE METALLIC SPRING LOADED LIFT COVERS LISTED
AND LABELED FOR USE IN WET LOCATIONS WHILE "IN USE".
7. ALL RECEPTACLES AND SWITCHES SHALL BE GROUNDED BY MEANS OF A GROUND
WIRE FROM DEVICE GROUND SCREW TO OUTLET BOX SCREW AND BRANCH CIRCUIT
GROUND CONDUCTOR. STRAP ALONE WILL NOT CONSTITUTE AN ACCEPTABLE
GROUND.
8. UNLESS OTHERWISE INDICATED, MOUNT FLUSH, WITH LONG DIMENSION
VERTICAL AND WITH GROUNDING TERMINAL OF RECEPTACLES ON TOP. GROUP
ADJACENT SWITCHES OR RECEPTACLES UNDER MULTIGANG WALL PLATES. PROVIDE
PROPER NEC BARRIERS IN BOXES WHICH SERVE DEVICES FOR BOTH THE NORMAL
AND EMERGENCY SYSTEMS.
9. AT EACH RECEPTACLE "IN" AND "OUT" PHASE AND NEUTRAL CONDUCTORS SHALL
HAVE AN ADDITIONAL CONDUCTOR FOR CONNECTION TO DEVICE. THE PRACTICE
OF "LOOPING" CONDUCTORS THROUGH RECEPTACLE BOXES SHALL NOT BE
ACCEPTABLE.
SECTION 26 41 13 - LIGHTNING PROTECTION SYSTEM
1. PROVIDE UL LABEL LIGHTNING PROTECTION SYSTEM. COMPLY WITH UL
96, NFPA 780, AND UFC 3-575-01 AND AFI 32-1065. CONTRACTOR SHALL
PROVIDE THIRD PARTY CERTIFICATIONS THAT THE SYSTEM MEETS BOTH AFI
32-1065 AND UL LABEL MINIMUM REQUIREMENTS.
2. INSTALLER SHALL BE LPI CERTIFIED AS A MASTER INSTALLER.
3. ROOF MOUNTED AIR TERMINALS SHALL BE NFPA CLASS 1, 1/2" DIAMETER
SOLID ALUMINUM, UNLESS OTHERWISE NOTED. TERMINAL TIP SHALL EXTEND
A MINIMUM OF 10" ABOVE THE OBJECT OR AREA IT IS PROTECTING.
4. TERMINAL BASES SHALL BE DESIGNED SPECIFICALLY FOR THE SPECIFIC
APPLICATION WHICH THEY ARE BEING UTILIZED.
5. ROOF MAIN CONDUCTORS SHALL BE ALUMINUM 95LB/1000 FT, 14 AWG STRAND,
98,600 CIRCULAR MILS MINIMUM. COPPER DOWN CONDUCTOR SHALL BE COPPER
187LB/1000FT, 17AWG STRAND, 57,400 CIRCULAR MIL MINIMUM. TRANSITION
FROM COPPER TO ALUMINUM SHALL BE VIA AN APPROVED BIMETALLIC CONNECTOR.
6. CABLE FASTENERS: ELECTROLYTICALLY COMPATIBLE WITH THE CONDUCTOR AND
MOUNTING SURFACE.
7. BONDING DEVICES, CABLE SPLICERS AND MISCELLANEOUS CONNECTORS: CAST
BRONZE WITH BOLT PRESSURE CONNECTIONS TO THE CABLE FOR ALL ABOVE
GROUND CONNECTIONS. EXOTHERMIC WELDED CONNECTION FOR ALL BELOW
GROUND CONNECTIONS. CAST OR STAMPED CRIMP FITTINGS ARE NOT ACCEPTABLE.
8. THRU ROOF ASSEMBLIES SHALL BE EQUIVALENT TO HARGER 230 SERIES.
PRE-MANUFACTURED ASSEMBLIES CONSISTING OF A BASE PLATE/CABLE
CONNECTOR, THREADED RISER BAR, 2 3/8" OD PVC TUBING SUPPORT, AND
CAP/CABLE CONNECTOR.
9. CONCEAL ALL CONDUCTORS FROM NORMAL VIEW FROM EXTERIOR LOCATIONS AT
GRADE WITHIN 200' OF THE CONDUCTOR.
10. USE APPROVED EXOTHERMIC-WELDED CONNECTED FOR ALL CONDUCTOR SPLICES
AND CONNECTIONS BETWEEN CONDUCTORS AND OTHER COMPONENTS BELOW
GRADE. UTILIZE A TORQUE WRENCH TO PROPERLY TIGHTEN ALL ABOVE GRADE
BOLTED CONNECTIONS. TIGHTEN IN ACCORDANCE WITH MANUFACTURERS
INSTRUCTIONS.
JH
F
EB
ELECTRICAL SPECIFICATIONS (con't.):
D at e D es cr ip tio n
D at e:
D ra w in g Fi le N am e:
D ra w n
By
M
AC
D
IL
L
AI
R F
O R
C E
BA
SE
, F
LO
R
ID
A
Sheet No.
D es ig ne d By
Ap pr ov ed
B y:
R ev ie w ed B y:
M ar k Ap pr
6T H
C
IV
IL
E
N G
IN
EE
R S
Q U
AD
R
O N
Facility I.D.
C
AD
D L ea de r:
IF
TH
IS
D
RA
W
IN
G
IS
LE
SS
TH
AN
" x
IT
IS
A
RE
DU
CE
D
SI
ZE
D
RA
W
IN
G.
D ec
5,
- 9
:1 7a m b y
E O
:\D R
AW
IN
G S\
Pr oj ec tN um be r\2 4-
\E -0
.d w g ofSheet
PR
O
JE
CT
N O
. N
VZ
R
D
EC
-4
CO
NV
ER
T
ED
C
EN
TE
R
TO
A
LS
B
JH
/ A
C M
F
IN
A L
A
P P
R O
V E
D F
O R
C O
N S
T R
U C
T
IO
N
E-003
E-
3.
dw g
EL
EC
TR
IC
AL
SP
EC
IF
IC
AT
IO
N S
J.
BA
SI
AG
A
J.
H
EN
R
Y
AutoCAD SHX Text
REV
AutoCAD SHX Text D
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text Y
AutoCAD SHX Text T
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text R
AutoCAD SHX Text I
INSTRUCTIONS.
11. COMPLY WITH ADHESIVE MANUFACTURER'S WRITTEN INSTRUCTIONS AND
COORDINATE WITH ROOFING MANUFACTURERS REQUIREMENTS.
12. THE ENTIRE INSTALLATION SHALL PROVIDE PROTECTION FROM ALLOWING
WATER INTRUSION NOT THE BUILDING ENVELOPE. DO NOT COMBINE
MATERIALS THAT CAN FORM AN ELECTROLYTIC COUPLE THAT WILL ACCELERATE
CORROSION IN THE PRESENCE OF MOISTURE UNLESS MOISTURE IS PERMANENTLY
EXCLUDED FROM JUNCTION OF SUCH MATERIALS.
13. USE CONDUCTORS WITH PROTECTIVE COATING WHERE CONDITIONS WOULD CAUSE
DETERIORATION OR CORROSION OF CONDUCTORS.
14. ALL COMPONENTS IN DIRECT CONTACT WITH EARTH SHALL BE COPPER.
15. CONTRACTOR SHALL SUBMIT SHOP DRAWING OF LIGHTNING PROTECTION
SYSTEM FOR ENGINEERS APPROVAL. SHOP DRAWINGS SHALL INCLUDE TYPES
AND LOCATION OF ALL AIR TERMINALS, CONDUCTORS, CONNECTORS,
GROUND RODS, METHODS AND TYPES OF BONDING. SUBMIT CATALOG CUTS
OF ALL EQUIPMENT.
SECTION 26 43 13 - SURGE PROTECTION DEVICES
1. PROVIDE SURGE PROTECTION DEVICES (SPD) THAT ARE UL1449 3RD EDITION
TESTED AND LABELED. SPD SHALL INCORPORATE FIELD REPLACEABLE MODULES
UTILIZING MOV TECHNOLOGY WITH A RESPONSE TIME OF 1 NANOSECOND OR
LESS. PROVIDE L-L, L-N, L-G, AND N-G MODES OF PROTECTION FOR ALL
SUPPRESSORS. ALL SUPPRESSORS SHALL HAVE A FAULT CURRENT RATING EQUAL
TO THAT OF THE EQUIPMENT/PANEL BEING PROTECTED. SPD MANUFACTURER SHALL
PROVIDE A 10 YEAR UNCONDITIONAL WARRANTY.
2. SERVICE ENTRANCE EQUIPMENT SPD SHALL BE RATED FOR 200KA SURGE
CAPACITY PER MODE MINIMUM. SERVICE ENTRANCE SPD SHALL CLAMP VOLTAGE
AT 800V L-L AND 400V ALL OTHER MODES FOR 120/208V SERVICES AND 1200V
L-L AND 1000V ALL OTHER MODES FOR 277/480V SERVICES.
3. BRANCH CIRCUIT PANELBOARD SPD SHALL BE RATED FOR 100KA SURGE CAPACITY
PER MODE MINIMUM. CLAMPING VOLTAGE SHALL BE THE SAME AS SERVICE
ENTRANCE SUPPRESSORS.
4. INSTALL ALL SPD ON THE SIDE OF EACH PANEL/EQUIPMENT BEING PROTECTED.
LEADS SHOULD BE KEPT AS SHORT AND STRAIGHT AS POSSIBLE AND IN NO CASE
SHOULD EXCEED MANUFACTURERS RECOMMENDED LEAD LENGTH. PROVIDE
OVERCURRENT PROTECTIVE DEVICE SIZE AS RECOMMENDED BY THE
MANUFACTURERS.
SECTION 26 51 00 - LIGHTING FIXTURES
1. PROVIDE ALL FIXTURES AS INDICATED IN THE FIXTURE SCHEDULE INCLUDING
MATCHING LAMP(S) FOR EACH FIXTURE. ALL FIXTURES MUST BE UL LABELED
AND INSTALLED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDED
INSTALLATION PROCEDURES.
2. ALL FLUORESCENT LIGHTING BALLAST SHALL BE ELECTRONIC, LESS THAN 20%
HARMONIC DISTORTION, SOUND RATING A, AND BE WIRED TO MAINTAIN FULL
LIGHT OUTPUT ON SURVIVING LAMPS IF ONE LAMP FAILS.
3. PROVIDE DIMMING BALLAST TO MATCH THE DIMMER SWITCH TO BE INSTALLED
WHEN REQUIRED FOR LOW VOLTAGE AND FLUORESCENT LIGHTING.
4. ALL FLUORESCENT LAMPS SHALL HAVE HIGH COLOR RENDERING (85 CRI) AND
PROVIDE A COLOR TEMPERATURE OF 3500K INTERIOR AND 4100K EXTERIOR
UNLESS OTHERWISE NOTED.
5. EXIT SIGNS SHALL BE INTERNALLY LIGHTED BY LED WITH A 70,000 HOUR
MINIMUM LAMP LIFE AND BE SELF POWERED BY BATTERY TO REMAIN LIGHTED
FOR 90MIN DURATION UPON LOSS OF POWER. BATTERY SHALL BE WARRANTED
FOR A PERIOD OF NOT LESS THAN 5 YEARS.
6. ALL EMERGENCY FIXTURES SHALL PROVIDE BATTERY BACK-UP FOR 90 MIN UPON
LOSS OF POWER. PROVIDE 1100 LUMEN EMERGENCY BATTERY PACKS FOR 90 MIN
BACK UP OF FIXTURES AS INDICATED ON THE PLANS.
7. PROVIDE TUBE GUARDS AROUND ALL EXPOSED TUBE (NO LENS) FIXTURES.
7. PROVIDE TUBE GUARDS AROUND ALL EXPOSED TUBE (NO LENS) FIXTURES.
8. PROVIDE FIXTURE SUPPORTS TO ALLOW FOR A REDUNDANT SUPPORT (ALLOW FOR
FAILURE OF ONE SUPPORT POINT) FOR ALL FIXTURES. PROVIDE APPROPRIATE
SLOPED CEILING ADAPTERS FOR SLOPED CEILINGS.
9. COORDINATE THE CEILING TRIM TYPE WITH THE ACTUAL CEILING TO BE
INSTALLED.
10. PROVIDE FOUNDATION FOR ALL SITE LIGHTING FIXTURES AND POLES IN
ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS.
11. ALL EXTERIOR MOUNTED FIXTURES, POLES, AND BASES SHALL BE DESIGNED
AND MANUFACTURED TO WITHSTAND 130MPH WIND.
SECTION 27 26 26 - TELEPHONE/DATA/CATV
1. GENERAL: FURNISH AND INSTALL, COMPLETE WITH ALL ACCESSORIES AN EIA/TIA
568-B.2-1 CATEGORY 6 PREMISE DISTRIBUTION SYSTEM (PDS) WITH A MINIMUM
25-YEAR, LINK AND CHANNEL WARRANTY FOR THE ENTIRE SYSTEM. THIS WARRANTY
SHALL PROVIDE FOR GUARANTEED SYSTEM PERFORMANCE AND THE REPLACEMENT
OF ANY DEFECTIVE PRODUCTS OR INSTALLATION.
2. WORK INCLUDED: PROVIDE WIRING, TERMINATIONS AND PATCH BAYS BETWEEN
THESE DESIGNATED DEMARCATION POINTS AND OUTLET LOCATIONS DESIGNATED ON
THE PLANS SHALL BE CONSIDERED PART OF THE CONTRACT.
3. MACDILL AFB HAS STANDARDIZED ON THE FOLLOWING COLOR CODE FOR CATEGORY
6 COMPONENTS. (VOICE-"GRAY") AND (DATA-"BLUE"). EACH OF THE FOLLOWING
COMPONENTS SHALL BE COLOR MATCHED TO ALLOW FOR SYSTEM "COLOR CODING"
CAT. 6 CABLE JACKET, PATCH CORDS AND CAT. 6 JACKS.
4. GENERAL: CABLE ROUTING AND INSTALLATION PRACTICES SHALL BE IN
ACCORDANCE WITH BICSI'S TELECOMMUNICATIONS DISTRIBUTION METHODS MANUAL
(TDMM) AND TELECOMMUNICATIONS INSTALLATION MANUAL.
5. AVOIDING EMI: TO AVOID EMI, ALL PATHWAYS SHALL PROVIDE CLEARANCES OF
AT LEAST 4 FEET (1.2 METERS) FROM MOTORS OR TRANSFORMERS; 1 FOOT (12
INCHES) FROM CONDUIT AND CABLES USED FOR ELECTRICAL POWER DISTRIBUTION;
AND 1 FOOT (12 INCHES) FROM FLUORESCENT LIGHTING. PATHWAYS SHALL CROSS
PERPENDICULAR TO FLUORESCENT LIGHTING AND ELECTRICAL POWER CABLES AND
CONDUITS.
6. GENERAL: COMMUNICATIONS OUTLETS THAT CONTAIN COPPER SERVICES SHALL BE
EQUIPPED WITH ANSI/TIA/EIA-568-B.2-1 CATEGORY 6, 8-POSITION MODULAR
JACKS (RJ45 TYPE) UTILIZING T568A WIRING. ALL OUTLET CABLING SHALL
TERMINATE ON APPROPRIATE TERMINATION BLOCKS AT THEIR ASSOCIATED IDF.
OUTLET JACK MODULE ARRANGEMENT AND QUANTITIES ARE SHOWN ON THE
DRAWINGS. OUTLETS SHALL BE CERTIFIED TO OPERATE AT 1000 MBPS DATE
SPEED WITH TWISTED PAIR TERMINAL WIRING AS VERIFIED BY ETL OR UL.
FACEPLATES SHALL BE ABLE TO ACCOMMODATE UP TO 6, 8-POSITION MODULAR
JACKS EACH.
7. OUTLET LABELING: EACH JACK ON ALL OUTLETS SHALL BE IDENTIFIED WITH
PERMANENT MACHINE GENERATED LABELS, MEETING THE EIA/TIA 606
REQUIREMENTS, MATCHING THE NUMBERING PLAN INDICATED ON THE DRAWINGS
WITH THE ADDITION OF A LETTER SUFFIX INDICATING THE JACK POSITION
ON THE FACEPLATE. ALL LABELING MUST BE PERMANENT. ALL LABELING SHALL
BE A MINIMUM 12 PT. IN SIZE. ALL LABELING SYSTEMS SHALL BE SUBMITTED
TO THE ENGINEER FOR APPROVAL PRIOR TO FABRICATION.
8. GENERAL: DATA PAIRS SHALL BE EXTENDED BETWEEN THE OUTLET LOCATION
AND ITS ASSOCIATED IDF. THE CABLE SHALL CONSIST OF 4 PAIR 23 GAUGE,
SOLID COPPER CONDUCTORS, CERTIFIED TO THE CATEGORY 6 STANDARDS. ETL
OR UL VERIFIED FOR EIA/TIA ELECTRICAL PERFORMANCE COMPLY WITH FCC
PART 68. CABLES SHALL BE TERMINATED ON EACH OF THE 8-POSITION MODULAR
JACKS PROVIDED AT EACH OUTLET. VOICE JACKS SHALL ALSO UTILIZE THE
CABLE TYPE. ONLY VIRGIN MATERIALS SHALL BE USED.
9. LABELS: LABELING FOR COPPER TIE CABLING SHALL BE BY ROOM, OUTLET,
AND JACK POSITION NUMBER (SIMILAR TO PLATE LABELING) AT THE IDF END.
CABLE SHALL BE IDENTIFIED WITH IDF # AT THE OUTLET BOX END. PERMANENT
MACHINE TYPE PRINTED (1/8" MIN LETTERS) VINYL OR NYLON CLOTH LABELS
SHALL BE CONSIDERED ACCEPTABLE FOR THIS PURPOSE. IDENTIFICATION SHALL
MACHINE TYPE PRINTED (1/8" MIN LETTERS) VINYL OR NYLON CLOTH LABELS
SHALL BE CONSIDERED ACCEPTABLE FOR THIS PURPOSE. IDENTIFICATION SHALL
INCLUDE BE PROVIDED AT BOTH ENDS OF THE CABLE (IN JUNCTION BOX AT
JACK AND AT IDF PATCH). LABELS SHALL BE BY BRADY OR EQUAL.
10. GENERAL - HORIZONTAL CABLES SHALL BE SUSPENDED BY THE PRE-MAFACTURED
CAT 6 RATED J-HOOKS AND BY "CLIC" FASTENERS WITH CABLE INSERTS IN
CLOSETS WHERE J-HOOKS, LADDER TRAY OR RACK MANAGEMENT IS NOT AVAILABLE.
ALL SUPPORTS SHALL BE PERMANENTLY ATTACHED TO THE STRUCTURE USING DROP
ROD SUSPENSION, BEAM CLAMPS, OR WALL MOUNT TO THE STRUCTURAL METAL OR
WOODEN MEMBERS. THE J-HOOKS SHALL FEATURE A WIDE BASE LOOP WITH SMOOTH
CURVES TO ELIMINATE SNAG POTENTIAL AND CABLE DEFORMATION. ALL CABLES
SHALL UTILIZE SIRE BASKET STYLE CABLE TRAY, IN ACCORDANCE WITH
26 05 36, WHEN RUNNING CABLES DOWN THE CORRIDORS. J-HOOKS SHOULD ONLY
BE UTILIZED WHEN RUNNING WITHIN INDIVIDUAL ROOM SPACES AND SHOULD NOT
BE UTILIZED FOR LONG RUNS BACK TO THE IDF/MDF.
11. GENERAL: EACH IDF SHALL BE EQUIPPED WITH 19" EIA RACK(S), FLOOR
MOUNTED, TO HOUSE USER PROVIDED EQUIPMENT AND CONTRACTOR PROVIDED
TERMINATION BAYS FOR THE MULTIPLE CABLE TYPES. FLOOR MOUNTED RACKS
SHALL BE MOUNTED ON AN ISOLATION PAD AND UTILIZE NON-CONDUCTIVE
WASHERS TO SECURE THE RACK TO THE FLOOR. FLOOR MOUNTED OPEN RACKS
SHALL BE SECURED FROM THE TOP RAIL TO THE BACKBOARD IN THE ROOM WITH
A LENGTH OF CABLE RUNWAY TO PREVENT MOVEMENT. WALL RACKS SHALL BE
SECURELY FASTENED TO THE WALL STUDS WITH AT LEAST 1/4" HARDWARE. ALL
RACKS SHALL BE BONDED TO THE IDF GROUND BAR USING A STANDARD GROUND
LUG AND #6 JACKETED GREEN CABLE. DESIGN SELECTION HUBBELL #HPW84RR19.
12. EACH EQUIPMENT RACK WILL BE PROVIDED WITH THE FOLLOWING ACCESSORIES:
1. HORIZONTAL CABLE ORGANIZER.
2. POWER PLUG STRIP.
13. VERTICAL CABLE MANAGEMENT: FREE STANDING RELAY RACKS SHALL HAVE
VERTICAL CABLE MANAGEMENT INSTALLED ON EACH SIDE OF THE RACK. IF MORE
THAN ONE RACK IS INSTALLED, THEN EACH RACK WILL BE SEPARATED BY A
VERTICAL, DUCT STYLE CABLE MANAGER. BLACK 6" CHANNELS WITH COVERS.
14. PLYWOOD BACKBOARDS.
15. GENERAL: EQUIPMENT RACKS: SHALL BE EQUIPPED WITH 19" RACK MOUNTED,
8-POSITION MODULAR JACKS (RJ-45 TYPE), ON-KEYED, FACTORY CONFIGURED;
PATCH PANELS FOR TERMINATION OF ALL COPPER HORIZONTAL CABLES.
16. CATEGORY 6 MODULAR PATCH CORDS AND WORK-AREA CORDS: PATCH CORDS ARE
PROVIDED BY THE USER.
17. INSTALLATION OF CAT. 6 UTP CABLE SHALL BE IN ACCORDANCE WITH EIA/TIA
GUIDELINES FOR CAT. 6. REPLACE CABLE INSTALLATION AND TERMINATIONS
THAT DO NOT COMPLY.
18. ALL CABLE RUNS SHALL CONTAIN SERVICE SLACK PRIOR TO THE TERMINATION
POINT. PROVIDE 12-INCH SERVICE SLACK IN THE CEILING ABOVE EACH
OUTLET. SERVICE SLACK AT IDF SHALL CONSIST OF A 10 FOOT SLACK
SECTION ALL STATION CABLES LOCATED AND PLACED NEATLY IN THE CABLE
LADDER ABOVE THE EQUIPMENT RACK.
19. INSTALL A COMPLETE SET OF SUPPORTING J-HOOKSAND OTHER SUPPORTING
HARDWARE FOR THE SYSTEM AS PART OF THE PDW CONTRACT.
20. COMPLY WITH ALL REQUIREMENTS OF ETL 02-15 AND SUPPLEMENTS.
SECTION 28 31 00 - FIRE ALARM SYSTEM
1. PROVIDE A COMPLETE FULLY FUNCTIONAL ADDRESSABLE FIRE ALARM/MASS
NOTIFICATION SYSTEM IN ACCORDANCE WITH NFPA 101(2018), NFPA 70
(2017) NFPA 72 (2016), FLORIDA BUILDING CODE (2017) AND LOCAL
ORDINANCES, STANDARDS AND CODES AS INTERPRETED AND ENFORCED BY
THE LOCAL AUTHORITY HAVING JURISDICTION.
2. SYSTEM SHALL INCLUDE TELEPHONE DIALER TO TRANSMIT THE SUPERVISORY,
TROUBLE AND ALARM SIGNALS TO THE CONTINUOUSLY ATTENDED SUPERVISING
STATION. IF THE PANEL WILL COMMUNICATE WITH A MASTER PANEL AS PART
OF A LARGER SYSTEM, THE RESPONSIBILITY TO TRANSMIT AND RECEIVE THE
JH
F
EB
ELECTRICAL SPECIFICATIONS (con't.):
D at e D es cr ip tio n
D at e:
D ra w in g Fi le N am e:
D ra w n
By
M
AC
D
IL
L
AI
R F
O R
C E
BA
SE
, F
LO
R
ID
A
Sheet No.
D es ig ne d By
Ap pr ov ed
B y:
R ev ie w ed B y:
M ar k Ap pr
6T H
C
IV
IL
E
N G
IN
EE
R S
Q U
AD
R
O N
Facility I.D.
C
AD
D L ea de r:
IF
TH
IS
D
RA
W
IN
G
IS
LE
SS
TH
AN
" x
IT
IS
A
RE
DU
CE
D
SI
ZE
D
RA
W
IN
G.
D ec
5,
- 9
:1 7a m b y
E O
:\D R
AW
IN
G S\
Pr oj ec tN um be r\2 4-
\E -0
.d w g ofSheet
PR
O
JE
CT
N O
. N
VZ
R
D
EC
-4
CO
NV
ER
T
ED
C
EN
TE
R
TO
A
LS
B
JH
/ A
C M
F
IN
A L
A
P P
R O
V E
D F
O R
C O
N S
T R
U C
T
IO
N
E-004
E-
4.
dw g
EL
EC
TR
IC
AL
SP
EC
IF
IC
AT
IO
N S
J.
BA
SI
AG
A
J.
H
EN
R
Y
AutoCAD SHX Text
REV
AutoCAD SHX Text D
AutoCAD SHX Text N
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text Y
AutoCAD SHX Text T
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text R
AutoCAD SHX Text I
STATION. IF THE PANEL WILL COMMUNICATE WITH A MASTER PANEL AS PART
OF A LARGER SYSTEM, THE RESPONSIBILITY TO TRANSMIT AND RECEIVE THE
SIGNAL AT BOTH PANELS WILL BE THE RESPONSIBILITY OF THIS CONTRACT.
3. THE SECONDARY POWER SUPPLY FOR THE FIRE ALARM CONTROL PANEL SHALL
BE PROVIDED BY AN APPROPRIATE SIZED UNINTERRUPTIBLE POWER SUPPLY
(BATTERY) TO PROVIDE A MINIMUM OF 24 HOURS UNDER QUIESCENT LOAD AND
THEN BE CAPABLE OF 15 MINUTES AT MAXIMUM CONNECTED LOAD INCLUDING ALL
NOTIFICATION APPLIANCES USED FOR EVACUATION UNDER ALARM CONDITION
UPON FAILURE OF THE PRIMARY POWER SUPPLY.
4. PROVIDE WIRING AS REQUIRED BY THE SYSTEM MANUFACTURER AND APPLICABLE
CODES AND STANDARDS. ALL WIRING SHALL BE INSTALLED IN APPROPRIATELY
SIZED RED CONDUIT.
5. ALL REQUIRED CONTROL AND INTERLOCK WIRING BETWEEN THE FIRE ALARM
SYSTEM AND BUILDING EQUIPMENT SHALL BE PROVIDED. CONTROLS ARE
REQUIRED FOR FIRESMOKE DAMPERS, SMOKE DAMPERS, SUPPLY FANS, EXHAUST
FANS, SMOKE EVACUATION EQUIPMENT, AUTOMATIC FIRE EXTINGUISHING
SYSTEMS, SPRINKLER SYSTEM, TAMPER SWITCHES, ELEVATORS, AND DIMMING
SYSTEMS.
6. DUCT DETECTORS FOR BUILDINGS WITH A FACP SHALL BE FURNISHED UNDER
DIVISION 26, INSTALLED IN DUCTWORK BY DIVISION 23 AND WIRED BY
DIVISION 26.
7. THE AUTHORITY HAVING JURISDICTION REQUIRES SHOP DRAWINGS TO BE
SIGNED AND SEALED BY A REGISTERED PROFESSIONAL ENGINEER, CONTRACTOR
IS REQUIRED TO SUBMIT THE DRAWINGS AND INCLUDE IN HIS BID ALL COSTS
ASSOCIATED WITH HAVING A REGISTERED PROFESSIONAL ENGINEER (OTHER
THAN THE PERFORMANCE DESIGN ENGINEER OF RECORD) PERFORM THE SIGNING
AND SEALING OF THE SHOP DRAWINGS.
8. INSTALLATION SHALL BE PERFORMED BY A COMPANY SPECIALIZING IN
INSTALLING THE MANUFACTURERS PRODUCTS WITH A MINIMUM OF (5) FIVE
YEARS EXPERIENCE AND CERTIFIED BY THE STATE OF FLORIDA AS A FIRE
ALARM INSTALLER.
9. SIGNALING LINE CIRCUITS SHALL BE NFPA 72, CLASS B, STYLE 3. FIRE
ALARM SIGNAL INITIATION SHALL BE BY MANUAL PULL STATIONS, HEAT
DETECTORS, WATER FLOW, ACTIVATION HOOD FIRE SUPPRESSION SYSTEM.
10. FIRE ALARM SIGNAL INITIATION REQUIRES VERIFICATION FOR SMOKE
DETECTORS AND DUCT DETECTORS. ACTIVATION OF DUCT DETECTORS WILL
SHUT DOWN UNIT UPON DETECTION.
11. ALARM SIGNAL SHALL INITIATE ALL ALARM NOTIFICATION APPLIANCES,
IDENTIFY ALARM AT THE FACP, TRANSMIT SIGNAL TO CENTRAL RECEIVING
STATION, SHUT DOWN HVAC EQUIPMENT, AND RECORD EVENTS IN FACP
SYSTEM MEMORY.
12. SUPERVISORY SIGNAL INITIATION SHALL BE BY OPERATION OF A TAMPER
SWITCH.
13. TROUBLE SIGNAL INITIATION SHALL BE IN ACCORDANCE WITH NFPA 72 FOR
CLASS B, STYLE 3 CIRCUITS, LOSS OF PRIMARY POWER AT THE FACP, GROUND
OR BREAK IN FACP INTERNAL CIRCUITS, FAILURE OF BATTERY
CHARGING/CIRCUITRY, OR ABNORMAL POSITION OF ANY SWITCH AT THE FACP
OR ANNUNCIATOR.
14. SYSTEM TROUBLE AND SUPERVISORY SIGNAL ACTIONS WILL RING BELL FOR
TROUBLE AND ANNUNCIATE AT THE FACP AND ANNUNCIATOR PANEL.
15. COMPLY WITH ALL REQUIREMENTS OF UFC 3-600-01 AND 04-021-01 FOR
FIRE ALARM/MASS NOTIFICATION COMBINATION SYSTEMS.
JH
F
EB
ELECTRICAL SPECIFICATIONS (con't.):
D at e D es cr ip tio n
D at e:
D ra w in g Fi le N am e:
D ra w n
By
M
AC
D
IL
L
AI
R F
O R
C E
BA
SE
, F
LO
R
ID
A
Sheet No.
D es ig ne d By
Ap pr ov…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .