This is Addendum No. 1 dated July 24, 2025, issued by Dynamic Design Group, Inc. for the Bathroom/Shower Facility project at the U.P. State Fairgrounds in Escanaba, Michigan (Job No. 24-4587). The addendum revises the original bid documents by including previously omitted Mechanical, Electrical, and Plumbing (MEP) drawings in the complete plan set, updating the Table of Contents in Section 00 0110 to include Section 32 3113, and adding a new specification section for Chain Link Fences and Gates to Division 32 - Exterior Improvements. The project encompasses construction of a bathroom/shower facility with comprehensive specifications covering procurement and contracting requirements, general requirements, existing conditions, concrete work, masonry, wood/plastics/composites, thermal and moisture protection, finishes, specialties, earthwork, exterior improvements including sidewalks and fencing, and utilities with site sanitary sewerage systems.
The chain link fence specifications require matching existing fence configurations and include detailed requirements for 2.5-inch diameter line posts, 3-inch diameter corner and terminal posts, 1.66-inch diameter top and bottom rails, 2-inch diamond mesh fabric with 9-gauge wire, three-strand barbed wire with 45-degree support extension arms pointing north toward the bathroom/shower building, and galvanized steel construction meeting ASTM standards. All contractors must forward addenda to subcontractors and verify receipt, with attachments including the updated plan set, revised table of contents, and complete chain link fence specifications. The addendum does not specify pricing terms, funding sources, contract values, set-asides, or award timelines.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Addendum
Dynamic Design Group, i n c .
Engineers—Architects—Project Managers
Dynamic Design Group, Inc., 900 1st Avenue South, Escanaba, Michigan 49829 Ph. 906.786.3300 email: gen@ddgi-ddm.com www.ddgi-ddm.com
M dd de s i gn do c u ment m a na g e
Addendum No. 1 Date: July 24, 2025
Job Name: Bathroom/Shower Facility U.P. State Fairgrounds Escanaba, MI
Job No. 24-4587
The following is issued as a supplement or to revise the bid documents. The revision, and/or clarification of the bid documents are described below. Unless specifically changed by Addendum, the remainder of the bid documents shall remain in effect as originally issued. Attach this addendum to your copy of the bid documents and note its receipt on the Bid Form.
Addendum Items:
1 Drawings Entire Plan Set – MEP drawings included
The Mechanical, Electrical, and Plumbing drawings were inadvertently excluded from the plans. The entire set, including the MEP drawings, has been updated.
2 Specifications Division 00 – Procurement and Contracting Requirements Section 00 0110 – Table of Contents was revised to include the added Section 32 3113 – Chain Link Fences and Gates.
4 Specifications Division 32 – Exterior Improvements Section 32 3113 – Chain Link Fences and Gates was added to Division 32 – Exterior Improvements of the Specifications.
Attachments: Updated Plan Set, Revised Table of Contents and Chain Link Fence Specifications Note: Contractors shall forward Addenda to their subs and/or verify their subs have all Addenda.
24-4587 / U.P. State Fairgrounds Bathroom/Shower Facility
00 0110 - 1 TABLE OF CONTENTS -
REVISED 07-24-2025
SECTION 00 0110
TABLE OF CONTENTS - REVISED 07-24-2025
PROCUREMENT AND CONTRACTING REQUIREMENTS
2.01 DIVISION 00 -- PROCUREMENT AND CONTRACTING REQUIREMENTS
A. 00 0102 - Project Information B. 00 0110 - Table of Contents C. 00 1113 - Advertisement for Bids D. 00 2113 - Instructions to Bidders E. 00 4100 - Bid Form F. 00 5000 - Contracting Forms and Supplements G. 00 7200 - General Conditions H. General Conditions for Construction Document I. 00 7300 - Supplementary Conditions
SPECIFICATIONS
3.01 DIVISION 01 -- GENERAL REQUIREMENTS
A. 01 2200 - Unit Prices B. 01 2500 - Substitution Procedures C. Substitution Request Form (During Procurement) D. Substitution Request Form (During Construction) E. 01 3000 - Administrative Requirements F. 01 4000 - Quality Requirements G. 01 5000 - Temporary Facilities and Controls H. 01 5713 - Temporary Erosion and Sediment Control I. 01 6000 - Product Requirements J. 01 7000 - Execution and Closeout Requirements K. 01 7800 - Closeout Submittals
3.02 DIVISION 02 -- EXISTING CONDITIONS
A. 02 4100 - Demolition
3.03 DIVISION 03 -- CONCRETE
A. 03 3000 - Cast-in-Place Concrete B. 03 3511 - Concrete Floor Finishes
3.04 DIVISION 04 -- MASONRY
A. 04 2000 - Unit Masonry
3.05 DIVISION 06 -- WOOD, PLASTICS, AND COMPOSITES
A. 06 1000 - Rough Carpentry B. 06 1753 - Shop-Fabricated Wood Trusses
3.06 DIVISION 07 -- THERMAL AND MOISTURE PROTECTION
A. 07 3113 - Asphalt Shingles B. 07 4633 - Plastic Siding
3.07 DIVISION 09 -- FINISHES
00 0110 - 2 TABLE OF CONTENTS -
REVISED 07-24-2025
A. 09 2900 - Gypsum Board Assemblies B. 09 9123 - Interior Painting
3.08 DIVISION 10 -- SPECIALTIES
A. 10 2113.19 - Plastic Toilet Compartments B. 10 2800 - Toilet, Bath, and Laundry Accessories
3.09 DIVISION 31 -- EARTHWORK
A. 31 1000 - Site Clearing B. 31 2200 - Grading C. 31 2316 - Excavation D. 31 2323 - Fill
3.10 DIVISION 32 -- EXTERIOR IMPROVEMENTS
A. 32 1623 - Sidewalks B. 32 3113 - Chain Link Fences and Gates C. 32 9219 - Seeding
3.11 DIVISION 33 -- UTILITIES
A. 33 3113 - Site Sanitary Sewerage Gravity Piping
END OF SECTION
32 3113 - 1 CHAIN LINK FENCES AND
GATES
SECTION 32 3113
CHAIN LINK FENCES AND GATES
PART 1 GENERAL
1.01 REFERENCE STANDARDS
A. ASTM A392 - Standard Specification for Zinc-Coated Steel Chain-Link Fence Fabric; 2011a (Reapproved 2017).
B. ASTM A1011/A1011M - Standard Specification for Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, and Ultra-High Strength; 2018a.
C. ASTM F567 - Standard Practice for Installation of Chain-Link Fence; 2014a.
D. ASTM F1043 - Standard Specification for Strength and Protective Coatings on Steel Industrial
Fence Framework; 2017a.
E. ASTM F1083 - Standard Specification for Pipe, Steel, Hot-Dipped Zinc-Coated (Galvanized)
Welded, for Fence Structures; 2016.
F. CLFMI CLF-SFR0111 - Security Fencing Recommendations; 2014.
G. FS RR-F-191/1D - Fencing, Wire and Post Metal (Chain-Link Fence Fabric); 1990.
1.02 SUBMITTALS
A. Product Data: Provide data on fabric, posts, accessories, fittings and hardware.
B. Shop Drawings: Indicate plan layout, spacing of components, post foundation dimensions, hardware anchorage, and schedule of components. See CLFMI CLF-SFR0111 for planning and design recommendations.
1.03 QUALITY ASSURANCE
A. Fence Installer: Company with demonstrated successful experience installing similar projects and products, with not less than five years of documented experience.
PART 2 PRODUCTS
2.01 COMPONENTS
A. New fence shall match the existing fence, or as follows.
B. Line Posts: 2.5 inch diameter. Height to match existing fence line posts.
C. Corner and Terminal Posts: 3 inch diameter. Height to match existing corner and terminal posts.
D. Top Rail: 1.66 inch diameter, plain end, sleeve coupled.
E. Brace Rails at Corners: 1.66 inch diameter, plain end, sleeve coupled.
F. Bottom Rail: 1.66 inch diameter, plain end, sleeve coupled.
G. Fabric: 2 inch diamond mesh interwoven wire, 9 gage, 0.1483 inch thick, top selvage twisted tight, bottom selvage knuckle end closed.
H. Tie Wire: Minimum 6 gauge aluminum or 9 gauge steel; spaced 14" apart on each line post and 24" apart along the top rail. The fabric is attached to terminal posts with tension bands and tension bars, 18" on center, one less than the height of the fence, but no fewer than three".
I. Barbed Wire: Three twisted strands of 12.5 gauge wire with 2-point, 14 gauge barbs spaced 5 inches apart. Locate the top most strand of barbed wire approximately 12 inches above and approximately 12 inches out from the top rail. Space all strands of barbed wire at an approximately equal distance from each other. Match existing barbed wire or as listed above.
J. Barbed Wire Support Extension Arms: Arm shall make a 45 degree angle with the post. Support extension arms shall be fitted to the post tops. Extension arms shall be fabricated from pressed steel or malleable wrought iron, or either of these materials in conjunction with a cast base.
Provide a minimum weight of the arm material of 14 gauge. Provide a complete arm assembly of sufficient strength to support the barbed wire when stretched to proper tension. Galvanize all
32 3113 - 2 CHAIN LINK FENCES AND
GATES
arms in accordance with ASTM A153. Extension arms shall point north towards the bathroom/shower building. Match existing barbed wire support extension arms or as listed above.
2.02 MATERIALS
A. Posts, Rails, and Frames:
1. ASTM A1011/A1011M, Designation SS; hot-rolled steel strip, cold formed to pipe configuration, longitudinally welded construction, minimum yield strength of 50 ksi; zinc coating complying with ASTM F1043 and ASTM F1083.
2.03 ACCESSORIES
A. Caps: Cast steel galvanized; sized to post diameter, set screw retainer.
B. Fittings: Sleeves, bands, clips, rail ends, tension bars, fasteners and fittings; steel.
PART 3 EXECUTION
3.01 EXAMINATION
A. New fence shall match the existing fence, or as stated elsewhere in these specs.
B. Verification of Conditions: Verify that areas are clear of obstructions or debris.
3.02 INSTALLATION
A. Install framework, fabric, accessories in accordance with ASTM F567.
B. Place fabric on the Campground side of the posts and rails (to match the existing).
C. Provide top rail through line post tops and splice with 6 inch long rail sleeves.
D. Position bottom of fabric 2 inches above finished grade or to match existing.
E. Install hardware with fabric to match fence.
3.03 CLEANING
A. Leave immediate work area neat at end of each work day.
B. Clean jobsite of excess materials; scatter excess material from post hole excavations uniformly away from posts. Remove excess material if required.
C. Clean fence with mild household detergent and clean water rinse well.
D. Touch up scratched surfaces using materials recommended by manufacturer.