About this file

This document is an Addendum to an Invitation for Bid (IFB) for the 24-2472 First Floor South Garage Lighting Replacement project in the Richmond Airport located in Henrico County and the City of Richmond, Virginia. The contractor will be responsible for replacing various exterior lighting on the first floor of the South Parking Garage, the South Expansion Parking Garage, as well as interior and exterior lighting in both the North and South Garage Elevator Lobbies with LED lights. The project requires the removal of existing fixtures and the installation of new LED fixtures. Specific quantities are provided in the drawings. No bid due date or award date is mentioned, but the contract term is not specified.

The pricing terms, set asides, incumbent information, funding sources, and other financial details are not provided in this document. The focus is on the technical specifications, drawings, and phasing plan for the lighting replacement work. Contractors are required to field verify all existing conditions prior to ordering materials and commencing work.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MPS END View - Curve Lens

2.56" (65.02mm)

3.06" (77.7mm)

3.11" (79mm)

3" (76.2mm)

2.44" (62mm)

MPS END View - FLAT Lens

2.56" (65.02mm)

1.25" (31.8mm)

40.5" (1028.7mm)

46" (1168.4mm)

44" (1117.6mm)

Surface Mount Slots

48.06" (1220.7mm)

B1A C

D

B2

E F

8" LED DOWNLIGHT RETROFITGARAGE PARKING FIXTURE 4' LED COVE STRIP

EXIT LIGHTLED DOWNLIGHT

6" LED DOWNLIGHT RETROFIT

LED RETROFIT KIT FULL FACE LED WALL FORM

RECESSED, CEILING120-277173,500K LED

TYPE LUMENS LAMP TYPE VOLTAGE MOUNTING

2,000

INPUT WATTS

LITON LIGHTING, "CRTR8L" SERIES

LUMINAIRE DESCRIPTION:

1. PROVIDE SELF-FLANGED SATIN HAZE REFLECTOR WITH WHITE TRIM RING.

2. UTILIZES HIGH-BRIGHTNESS LEDS MOUNTED TO A METAL CORE CIRCUIT BOARD, ENSURING

COOL-RUNNING OPERATION, CRI>80.

3. HIGH-EFFICIENCY, INTEGRAL ELECTRONIC LED DRIVER. PROVIDE DIMMABLE DRIVER.

4. CERTIFICATION: CETLUS LISTED. SUITABLE FOR DRY, DAMP, AND WET LOCATIONS.

7. RETROFIT: DESIGNED FOR USE WITH EXISTING 8" ARCHITECTURAL FLOURESCENT HOUSING.

SUPPLIED WITH JUNCTION BOX AND FLEXIBLE METAL CONDUIT FOR CONNECTION TO EXISTING

8. ATTIC STOCK: CONTRACTOR SHALL PROVIDE 5 SPARE LIGHT FIXTURES IN ADDITION TO THE

QUANTITIES INDICATED ON THE PLANS FOR ATTIC STOCK.

SURFACE, CEILING120-27748.14000K LED

TYPE LUMENS LAMP TYPE VOLTAGE MOUNTING

5,502

INPUT WATTS

CURRENT LIGHTING, " BEACON SRT2 EDGE-LIT" SERIES

LUMINAIRE DESCRIPTION:

1. HOUSING: DIE-CAST ALUMINUM. ONE PIECE MOLDED SILICONE GASKET.

2. OPTICS: EDGE-LIT ACRYLIC LIGHT GUIDE.

3. FINISH: CORROSION RESISTANT POWDER COAT. WHITE GLOSS SMOOTH.

4. DISTRIBUTION: TYPE 5 WIDE.

5. CERTIFICATION: LISTED TO UL1598 FOR USE IN WET LOCATION. IP65.

6. ATTIC STOCK: CONTRACTOR SHALL PROVIDE 10 SPARE LIGHT FIXTURES IN ADDITION TO THE

QUANTITIES INDICATED ON THE PLANS FOR ATTIC STOCK.

SURFACE, COVE MOUNT120-27718.13500K LED

TYPE LUMENS LAMP TYPE VOLTAGE MOUNTING

2,544

INPUT WATTS

LUMINAIRE DESCRIPTION:

1. HOUSING: COLD ROLLED STEEL HOUSING, FLAT END CAPS.

2. PROVIDE WITH CURVED, FROSTED ACRYLIC LENS. WIDE DISTRIBUTION.

3. HIGH-EFFICIENCY, INTEGRAL ELECTRONIC LED DRIVER, 0-10V DIMMING.

4. UL LISTED AND DAMP LOCATION LISTED AND TESTED IN ACCORDANCE WITH IESNA LM-79 AND

LM-80 STANDARDS.

DETAIL BASED ON COLUMBIA LIGHTING, "MPS" SERIES

LUMINAIRE DESCRIPTION:

1. UV STABLE THERMOPLASTIC HOUSING

AND

LETTERS.

2. 6" TALL LETTERS.

3. RED ILLUMINATION PROVIDED BY LIGHT

EMITTING DIODES (LED). APPROXIMATELY

100 LED'S PER

FACE.

4. POWER FAILURE PROTECTION, BROWN

OUT PROTECTION, AND SURGE

PROTECTION.

5. SEALED, MAINTENANCE FREE, NICKEL

CADMIUM BATTERY WITH SOLID STATE

CHARGER AND OVERCHARGE

PROTECTION.

6. UNIVERSAL ARROWS AND BLANK OFF

PLATES.

7. SINGLE OR DOUBLE FACE AS INDICATED.

8. UNIVERSAL MOUNTING.

9. TEST BUTTON IN BOTTOM OF HOUSING.

10. INDICATOR LIGHTS TO INDICATE WHEN

UNIT IS ON NORMAL POWER OR ON

BATTERY

POWER.

11. WHITE FINISH.

DETAIL BASED ON DUAL-LITE LIGHTING, "EVE" SERIES

INDICATES WALL MOUNT 6" ABOVE DOOR TO BOTTOM OF FIXTURE.

INDICATES CEILING MOUNT.

11.5"

9"

UNIVERSAL MOUNT, CEILING, WALL120/2772LED

TYPE LAMP TYPE VOLTAGE MOUNTINGINPUT WATTS

LUMINAIRE DESCRIPTION:

1. LED DRIVER SHALL BE ELECTRONIC, HIGH POWER FACTOR ( > .95) WITH THD <20%, AND WITH

TRIAC: 100-5% DIMMING CAPABILITIES.

2. FIXTURE SHALL BE ALUMINUM BODY WITH ACRYLIC DIFFUSER.

3. FINISH SHALL BE WHITE.

4. FIXTURE SHALL BE 90 CRI.

5. UL LISTED AND DAMP LOCATION LISTED AND TESTED IN ACCORDANCE WITH IESNA LM-79 AND

LM-80 STANDARDS.

DETAIL BASED ON MODERN FORMS, "ARGO" SERIES

SURFACE, CEILING120-27727.53500K LED

TYPE LUMENS LAMP TYPE VOLTAGE MOUNTING

2,109

INPUT WATTS

JUNCTION BOX.

TYPE LUMENS LAMP TYPE VOLTAGE MOUNTINGINPUT WATTS

LITON LIGHTING, "CRTR6L" SERIES

LUMINAIRE DESCRIPTION:

1. PROVIDE SELF-FLANGED SATIN HAZE REFLECTOR WITH WHITE TRIM RING.

2. UTILIZES HIGH-BRIGHTNESS LEDS MOUNTED TO A METAL CORE CIRCUIT BOARD, ENSURING

COOL-RUNNING OPERATION, CRI>80.

3. HIGH-EFFICIENCY, INTEGRAL ELECTRONIC LED DRIVER. PROVIDE DIMMABLE DRIVER.

4. CERTIFICATION: CETLUS LISTED. SUITABLE FOR DRY, DAMP, AND WET LOCATIONS.

7. RETROFIT: DESIGNED FOR USE WITH EXISTING 6" ARCHITECTURAL FLOURESCENT HOUSING.

SUPPLIED WITH JUNCTION BOX AND FLEXIBLE METAL CONDUIT FOR CONNECTION TO EXISTING

8. ATTIC STOCK: CONTRACTOR SHALL PROVIDE 5 SPARE LIGHT FIXTURES IN ADDITION TO THE

QUANTITIES INDICATED ON THE PLANS FOR ATTIC STOCK.

RECESSED, CEILING120-277283,500K LED2,900

JUNCTION BOX.

TYPE LUMENS LAMP TYPE VOLTAGE MOUNTINGINPUT WATTS

KIM LIGHTING, "WF-LED-KIT" SERIES

SURFACE, CEILING120-277204000K LED2,100

LUMINAIRE DESCRIPTION:

1. LED OPTICAL SYSTEM: 9 LED EMITTERS CONFIGURED IN A RECTANGULAR ARRAY COMPRISED

TOGETHER AS A MODULE. (2) MODULES.

2. DRIVER: RATED FOR 18 LED. UNIVERSAL VOLTAGE. 40 DEGREE STARTING TEMPERATURE.

3. CERTIFICATIONS AND LISTINGS: UL 1598 STANDARD FOR WET LOCATIONS. UL 8750 STANDARD

FOR LED EQUIPMENT FOR USE IN LIGHTING PRODUCTS.

TYPE LUMENS LAMP TYPE VOLTAGE MOUNTINGINPUT WATTS

KIM LIGHTING, "WF20" SERIES

SURFACE, CEILING120-27711.94200K LED1,135

LUMINAIRE DESCRIPTION:

1. LED OPTICAL SYSTEM: 9 LED EMITTERS CONFIGURED IN A RECTANGULAR ARRAY COMPRISED

TOGETHER AS A

MODULE.

2. FIXTURE SHALL BE ALUMINUM BODY WITH ACRYLIC DIFFUSER.

3. FINISH SHALL BE WHITE MATTE TEXTURED FINISH.

4. UL 1589 & 8750 LISTED, SUITABLE FOR WET LOCATIONS..

LIGHTING ARRANGEMENT: ARRANGE LIGHTING FIXTURES IN

ACCORDANCE WITH THE ARCHITECTURAL REFLECTED CEILING

PLANS.

LIGHTING COORDINATION: COORDINATE LIGHTING FIXTURES WITH

GRILLES, DIFFUSERS, SPRINKLER HEADS, AND ACCESS PANELS,

ETC. PROVIDE FIXTURE MOUNTING BRACKETS, ACCESSORIES,

PLASTER FRAMES, ETC.. SUITABLE FOR THE CEILING TYPES

INDICATED ON THE ARCHITECTURAL PLANS.

LIGHTING CONTROL TESTING: UPON COMPLETION OF THE

INSTALLATION OF ALL LIGHTING SYSTEMS AND CONTROL DEVICES,

CONTRACTOR SHALL CONFIRM PROPER OPERATION OF ALL

LIGHTING CONTROLS, AND DEMONSTRATE PROPER OPERATION TO

THE OWNER AND/OR ENGINEER.

MATERIAL COORDINATION: VERIFY CEILING AND WALL

CONSTRUCTION AND MATERIAL PRIOR TO ORDERING LIGHT

FIXTURES OR OTHER DEVICES TO ENSURE PROPER FIXTURE OR

DEVICE IS FURNISHED TO MATCH CONSTRUCTION.

MOUNTING HEIGHTS: MOUNTING HEIGHTS INDICATED ARE FROM

THE FINISHED FLOOR TO THE CENTERLINE OF THE WIRING DEVICE

UNLESS OTHERWISE NOTED. MOUNTING HEIGHTS OF LIGHTING

FIXTURES ARE TO THE BOTTOM OF THE FIXTURE UNLESS

OTHERWISE NOTED.

J-BOX LABELING: LABEL ALL JUNCTION BOXES WITH PERMANENT

MARKER IDENTIFYING CIRCUIT NUMBER AND PANELBOARD OF

CIRCUITS WITHIN.

WIRING DEVICES: LABEL ALL WIRING DEVICES WITH PANELBOARD

AND CIRCUIT DESIGNATION PERMANENTLY ATTACHED WITH BLACK

TYPED DESIGNATION ON CLEAR TAPE.

GENERAL: UNLESS SPECIFICALLY INDICATED OTHERWISE, ALL WORK

SHOWN ON ELECTRICAL DRAWINGS IS NEW WORK TO BE PROVIDED

UNDER THIS CONTRACT.

COORDINATION: COORDINATE AND COOPERATE WITH ALL TRADES

ON THE PROJECT. THE CONTRACTOR SHALL REVIEW ALL CONTRACT

DOCUMENTS INCLUDING CIVIL, STRUCTURAL, ARCHITECTURAL

DRAWINGS AND SPECIFICATIONS. CONTRACTOR SHALL COORDINATE

AND ADJUST ACCORDINGLY AS DIRECTED BY THE ENGINEER.

AS-BUILT DRAWINGS: SECURE AN EXTRA SET OF ELECTRICAL

DRAWINGS TO BE KEPT ON SITE AND MARK, DAILY, THE DRAWINGS IN

RED AS THE PROJECT PROGRESSES IN ORDER TO KEEP AN

ACCURATE RECORD OF ALL DEVIATIONS BETWEEN THE WORK

SHOWN ON THE DRAWINGS AND THE WORK WHICH IS ACTUALLY

INSTALLED. THESE MARKED DRAWINGS SHALL REFLECT ANY AND ALL

CHANGES AND REVISIONS TO THE ORIGINAL DESIGN WHICH EXISTS

IN THE COMPLETED WORK. DELIVER THE MARKED DRAWINGS TO THE

OWNER AT PROJECT CLOSE-OUT.

TESTS: TEST ALL WIRING FOR CONTINUITY AND GROUNDS BEFORE

CONNECTING ANY FIXTURES OR DEVICES. PERFORM INSULATION

RESISTANCE TESTS ON ALL WIRING #6 OR LARGER TO ENSURE THAT

ALL PORTIONS ARE FREE FROM SHORT-CIRCUITS AND GROUNDS.

INSPECTIONS: ARRANGE ALL NECESSARY INSPECTIONS. DELIVER ALL

REQUIRED INSPECTION CERTIFICATES TO THE OWNER.

GROUNDING: PROVIDE GROUNDING IN ACCORDANCE WITH THE NEC

FOR THE ENTIRE ELECTRICAL SYSTEM INCLUDING EQUIPMENT

FRAMES, CONDUITS, SWITCHES, CONTROLLERS, WIRE-WAYS,

NEUTRAL CONDUCTORS, AND OTHER EQUIPMENT. PROVIDE A

GROUNDING CONDUCTOR IN ALL POWER CONDUITS.

LIGHTING

EMERGENCY LIGHTING FIXTURE CONNECT TO LIFE SAFETY LIGHTING

CIRCUIT

DOWNLIGHT FIXTURE

EXIT LIGHTING FIXTURE, WITH DIRECTIONAL ARROWS AS INDICATED.

LIGHTING FIXTURE TYPE SYMBOL. SEE LIGHTING FIXTURE DETAILS.

ELECTRICAL CIRCUIT RUN IN CONDUIT AND CIRCUIT HOMERUN TO

PANELBOARD (PANEL AND CIRCUIT DESIGNATION AS INDICATED). AS A

MINIMUM CONDITION, EACH SINGLE PHASE CIRCUIT SHALL HAVE 1 #12

PHASE CONDUCTOR, 1 #12 NEUTRAL CONDUCTOR AND 1 #12 GROUNDING

CONDUCTOR IN 1/2" CONDUIT. PROVIDE ADDITIONAL PHASE CONDUCTORS

AS REQUIRED FOR "MULTIPLE PHASED" ELECTRICAL LOADS. PROVIDE

NEUTRAL CONDUCTOR TO ALL WALL SWITCH OUTLET BOXES WHETHER

REQUIRED OR NOT. PROVIDE ADDITIONAL "SWITCH LEG" CONDUCTORS TO

PROVIDE THE LIGHT FIXTURE CONTROL INDICATED. MULTIPLE SINGLE

PHASE CONDUCTORS MAY BE GROUPED TOGETHER IN A COMMON CONDUIT

IN ACCORDANCE WITH THE NEC AND AT THE CONTRACTOR'S DISCRETION.

GROUNDING CONDUCTORS MAY BE SHARED AS ALLOWED BY THE NEC.

NEUTRAL CONDUCTORS SHALL NOT BE SHARED. MULTI-POLE BREAKERS

SHALL BE PROVIDED IN ACCORDANCE WITH THE NEC WHERE MULTI-WIRE

BRANCH CIRCUITS ARE REQUIRED. CONDUIT LARGER THAN 1/2" AND

CONDUCTORS LARGER THAN #12 SHALL BE AS INDICATED.

AND

SUBSCRIPT 'x' INDICATES LIGHTING FIXTURE CONTROLLED AND ASSOCIATED CONTROL

DEVICE(S).

GENERAL

NEW WORK NOTE SYMBOL1

A

COVE LIGHTING FIXTURE

PARKING GARAGE LIGHTING FIXTURE

A AMPERE

AFF ABOVE FINISHED FLOOR

C CONDUIT

CFCI CONTRACTOR FURNISHED,

CONTRACTOR INSTALLED

CKT CIRCUIT

ETR EXISTING TO REMAIN

EXIST EXISTING

GND GROUND

LPW LUMENS PER WATT

LTG LIGHTING

MCB MAIN CIRCUIT BREAKER

MFR MANUFACTURER

MLO MAIN LUGS ONLY

MTD MOUNTED

NEC NATIONAL ELECTRICAL CODE

NIC NOT IN CONTRACT

OC ON CENTER

OFCI OWNER FURNISHED,

CONTRACTOR INSTALLED

OFOI OWNER FURNISHED,

OWNER INSTALLED

P POLE

PF POWER FACTOR

PNL PANEL

Ø PHASE

PRI PRIMARY

SE SERVICE ENTRANCE

SEC SECONDARY

TYP TYPICAL

UON UNLESS OTHERWISE NOTED

V VOLT

W WATTS/WIRE

DE DOMINION ENERGY

MOCP MAXIMUM OVER-CURRENT

PROTECTION

N NORMAL

OSP OUTSIDE PLANT

SCH SCHEDULE

GENERAL: DEMOLITION DRAWINGS ARE BASED ON EXISTING PLANS

AND FIELD INVESTIGATION PRIOR TO DEMOLITION. VISIT THE

EXISTING BUILDING PRIOR TO BID IN ORDER TO BECOME FAMILIAR

WITH THE EXISTING CONDITIONS AND IN ORDER TO AVOID

CONFLICTS.

DASHED ITEMS: ALL ITEMS SHOWN DASHED ON DEMOLITION PLANS

ARE EXISTING AND SHALL BE REMOVED.

SOLID ITEMS: ALL ITEMS SHOWN SOLID ON DEMOLITION PLANS ARE

EXISTING TO REMAIN.

CIRCUITING TO REMAIN: EXISTING CIRCUITING TO REMAIN SHALL BE

REROUTED OR RECONNECTED, AS REQUIRED, WHERE AFFECTED BY

NEW WORK IN ORDER TO MAINTAIN CONTINUITY OF THE CIRCUIT.

REUSE OF EXISTING CIRCUITRY: EXISTING CIRCUITRY SERVING

LIGHTING FIXTURES AND/OR RECEPTACLES FOR A GIVEN AREA SHALL

BE REUSED WHERE INDICATED TO SERVE THE NEW LAYOUT.

PROVIDE CIRCUIT MODIFICATIONS INDICATED OR AS OTHERWISE

REQUIRED TO MAINTAIN THE CONTINUITY OF EXISTING CIRCUITS

THAT REMAIN.

EXISTING CONDUIT: ALL EXISTING CONDUITS AND WIRING THAT WILL

NOT BE REUSED SHALL BE REMOVED WHERE THEY WILL BE EXPOSED

UPON COMPLETION OF NEW WORK. EXISTING CONDUIT TO REMAIN

CONCEALED IN WALLS SHALL BE ABANDONED. EXISTING CONDUIT TO

REMAIN BELOW FLOOR SLAB SHALL BE CUT OFF ONE INCH BELOW

ROUGH FLOOR AND GROUTED FLUSH. ALL EXISTING WIRING IN

CONDUITS TO BE ABANDONED SHALL BE DISCONNECTED FROM

POWER SOURCE AND REMOVED.

REPAIR DAMAGE: EXERCISE CARE IN REMOVAL OF DEMOLITION

ITEMS. REPAIR, AT NO ADDITIONAL COST TO THE OWNER, ANY

DAMAGE CAUSED TO EXISTING CONSTRUCTION AND/OR EQUIPMENT

TO REMAIN.

KNOCKOUT PLUGS AND COVERS: ALL CONDUIT REMOVED SHALL BE

REMOVED IN ITS ENTIRETY, INCLUDING FITTINGS, MOUNTING

DEVICES, MOUNTING HARDWARE, ETC. PROVIDE CONDUIT PLUGS

AND BLANKS FOR ALL OPENINGS CREATED BY THE REMOVAL OF

CONDUIT. PROVIDE BLANK COVER PLATES FOR ALL OPENED OUTLET

BOXES CREATED BY THE REMOVAL OF EQUIPMENT AND/OR DEVICES

DEMOLISHED MATERIALS: ALL MATERIALS REMOVED UNDER

DEMOLITION, NOT TO BE RELOCATED OR DESIGNATED TO BE TURNED

OVER TO THE OWNER, SHALL BECOME THE PROPERTY OF THE

CONTRACTOR AND SHALL BE REMOVED COMPLETELY FROM THE

SITE.

SCHEDULE OUTAGES: ALL WORK AND ALL POWER OUTAGES IN THE

EXISTING BUILDING SHALL BE SCHEDULED AT TIMES CONVENIENT TO

THE OWNER.

NOTIFICATION: NOTIFY THE OWNER PRIOR TO TURNING OFF ANY

CIRCUITS.

LIGHTING FIXTURE SIZE NOTE:

CONTRACTOR SHALL FIELD VERIFY THE EXACT SIZE OF ALL

FIXTURES, ROUGH OPENINGS, AND CEILING

MATERIALS/THICKNESSES PRIOR TO ORDERING.

D ra w n B y

C h e c k e d B y

A p p ro v e d B y

919 E Main Street Suite 1200

Richmond, VA 23219 804.788.0710

This Line is 3 Inches When Printed Full Size

#24141

NOT F

OR

CONSTRUCTIO

N

IF

B

N U

M B

E R

-2

/2

/2

:1

:4

P

M A u to d e s k D o c s

/R

IC

A ir p o rt

R

/4

.4

E le c tr ic a l.

rv t

C L

K J N

K J N

R

IC

S O

U T

H G

A R

A G

E L

IG

H T

IN

G

R E

P L A

C E

M E

N T

R

IC

H

A R

D E

B Y

R D

T E

R M

IN

A

L D

R

R

IC

H M

O N

D V

A

LEGEND, NOTES AND

ABBREVIATIONS

E001 45533.46

06.17.2024

GreshamSmith.com

GENERAL NOTES LEGEND ABBREVIATIONSDEMOLITION NOTES

Revision

No. Date Description

1 7.23.24 ADDENDUM #1

7.29.24

K .1

K .2 L

M N P Q R

.5

.8

.8

.8

.5

.9

.7

.2

.5

.9

.9

.4

.2

.6

55'-0"55'-0"55'-0"55'-0"55'-0"

12'-6"25'-0"12'-6"

V A

N V

A N

K .1

K .2 L

M N P Q R

.5

.8

.8

.8

.5

.9

.7

.2

.5

.9

.9

.4

.2

.6

55'-0"55'-0"55'-0"55'-0"55'-0"

12'-6"25'-0"12'-6"

V A

N V

A N

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

P A

R T

G

PART G6

PART G5

P A

R T

G

PART G7

PART G8

E

E 2

E 2

E2

E 2

F

1 REMOVE ALL EXISTING LIGHT FIXTURES THIS SPACE

AND RETAIN ASSOCIATED BACKBOX AND CIRCUITING.

PROVIDE FIXTURE INDICATED, AND CONNECT TO

RETAINED BACKBOX AND CIRCUITING, UON. EXTEND

2 #12, 1 #12 GND - 1/2"C AS REQUIRED.

50'30'10'0' 5' 20'5' 1/16" = 1'-0"

D ra w n B y

C h e c k e d B y

A p p ro v e d B y

919 E Main Street Suite 1200

Richmond, VA 23219 804.788.0710

This Line is 3 Inches When Printed Full Size

#24141

GRAPHIC SCALE:

NOT F

OR

CONSTRUCTIO

N

IF

B

N U

M B

E R

-2

/2

/2

:1

:4

P

M A u to d e s k D o c s

/R

IC

A ir p o rt

R

/4

.4

E le c tr ic a l.

rv t

C L

K J N

K J N

R

IC

S O

U T

H G

A R

A G

E L

IG

H T

IN

G

R E

P L A

C E

M E

N T

R

IC

H

A R

D E

B Y

R D

T E

R M

IN

A

L D

R

R

IC

H M

O N

D V

A

FIRST FLOOR -

LIGHTING PLAN - G7

GARAGE

E103 45533.46

06.17.2024

GreshamSmith.com

B

CONCOURSE A CONCOURSE B

ATRIUM

DEPARTURES TERMINALAC

D

E

F G H

I

J K L

G3

G4

G1

G2

G7

G8

G5

G6

ELEVATED ROADWAY

NORTH GARAGE SOUTH GARAGE

SCALE: 1/16" = 1'-0"

FIRST FLOOR - LIGHTING PLAN - G7 GARAGE

NOTES THIS SHEET

Revision

No. Date Description

1 7.23.24 ADDENDUM #1

K

0.

.8

.8

.8

8.

6.

6.

K .1

7.

K

0.

.8

.8

.8

8.

6.

6.

K .1

7.

1 1 1 1 1

1 1 1 1 1

1 1 1 1 1

1 1 1 1 1

1 1

A A A A A

A A A A A

A A A A A

A A A A A

A A A A A

A A A A

A A

PART G7

PART G8

P A

R T

G

P A

R T

G

PART G7

PART G8

E

E

1 REMOVE ALL EXISTING LIGHT FIXTURES THIS SPACE

AND RETAIN ASSOCIATED BACKBOX AND CIRCUITING.

PROVIDE FIXTURE INDICATED, AND CONNECT TO

RETAINED BACKBOX AND CIRCUITING, UON. EXTEND

2 #12, 1 #12 GND - 1/2"C AS REQUIRED.

50'30'10'0' 5' 20'5' 1/16" = 1'-0"

D ra w n B y

C h e c k e d B y

A p p ro v e d B y

919 E Main Street Suite 1200

Richmond, VA 23219 804.788.0710

This Line is 3 Inches When Printed Full Size

#24141

GRAPHIC SCALE:

NOT F

OR

CONSTRUCTIO

N

IF

B

N U

M B

E R

-2

/2

/2

:1

:4

P

M A u to d e s k D o c s

/R

IC

A ir p o rt

R

/4

.4

E le c tr ic a l.

rv t

C L

K J N

K J N

R

IC

S O

U T

H G

A R

A G

E L

IG

H T

IN

G

R E

P L A

C E

M E

N T

R

IC

H

A R

D E

B Y

R D

T E

R M

IN

A

L D

R

R

IC

H M

O N

D V

A

FIRST FLOOR -

LIGHTING PLAN - G8

GARAGE

E104 45533.46

06.17.2024

GreshamSmith.com

SCALE: 1/16" = 1'-0"

FIRST FLOOR - LIGHTING PLAN - G8 GARAGE

NOTES THIS SHEET

B

CONCOURSE A CONCOURSE B

ATRIUM

DEPARTURES TERMINALAC

D

E

F G H

I

J K L

G3

G4

G1

G2

G7

G8

G5

G6

ELEVATED ROADWAY

NORTH GARAGE SOUTH GARAGE

Revision

No. Date Description

1 7.23.24 ADDENDUM #1

12'-6" 12'-6"

B1 B1

B1

B1

B1

B1

B1

B1 B1

B1 B1

B1 D

B1

C

D

B1

B1 B1

C 1

1 11

C C

B1B1

B1

B1

B1

B1

B1

B1

B1

B1 B1

B1 D

B1

C

D

B1

B1 B1

C

B1

B1

B1

B1

B1B1

B1 B1

B1 D

B1

C

B1

B1

B1

D

B1

B1 B1

C

B1

B1

B1

B1

B1 B1

B1 B1

B1

B1 B1

B2B2

B2 B2 B2 B2

B2

B2

B1 B1

B2

B1

C

B2

B2

B2

B1

B1

B2

B2

B2

4 4

1 REMOVE EXISTING LIGHT FIXTURE AND RETAIN ASSOCIATED BACKBOX AND

CIRCUITING. PROVIDE FIXTURE INDICATED, AND CONNECT TO RETAINED BACKBOX

AND CIRCUITING. EXTEND 2 #12, 1 #12 GND - 1/2"C AS REQUIRED.

REMOVE EXISTING FIXTURE AND PROVIDE BLANK COVERPLATE ON EXISTING

JUNCTION BOX AND/OR REPAIR OPENING TO MATCH ADJACENT FINISHES.

REMOVE EXISTING LAMP, REFLECTOR, AND BALLAST AND PROVIDE LED RETROFIT

FIXTURE AS INDICATED, UON.

ENLARGE EXISTING 6" OPENING TO ACCOMODATE 8" FIXTURE. CUT AND PATCH

CEILING AS REQUIRED.

1/8" = 1'-0" 5'0'5' 10' 20'

D ra w n B y

C h e c k e d B y

A p p ro v e d B y

919 E Main Street Suite 1200

Richmond, VA 23219 804.788.0710

This Line is 3 Inches When Printed Full Size

#24141

GRAPHIC SCALE:

NOT F

OR

CONSTRUCTIO

N

IF

B

N U

M B

E R

-2

/2

/2

:1

:4

P

M A u to d e s k D o c s

/R

IC

A ir p o rt

R

/4

.4

E le c tr ic a l.

rv t

C L

K J N

K J N

R

IC

S O

U T

H G

A R

A G

E L

IG

H T

IN

G

R E

P L A

C E

M E

N T

R

IC

H

A R

D E

B Y

R D

T E

R M

IN

A

L D

R

R

IC

H M

O N

D V

A

NORTH & SOUTH

GARAGE ELEVATOR

ROOM LIGHTING

PLANS

E105 45533.46

06.17.2024

GreshamSmith.com

SCALE: 1/8" = 1'-0"

NORTH & SOUTH GARAGE ELEVATOR ROOM FIRST FLOOR LIGHTING PLAN

SCALE: 1/8" = 1'-0"

NORTH & SOUTH GARAGE ELEVATOR ROOM SECOND FLOOR LIGHTING PLAN

SCALE: 1/8" = 1'-0"

NORTH & SOUTH GARAGE ELEVATOR ROOM THIRD FLOOR LIGHTING PLAN

SCALE: 1/8" = 1'-0"

NORTH & SOUTH GARAGE ELEVATOR ROOM FOURTH FLOOR LIGHTING PLAN

B

CONCOURSE A CONCOURSE B

ATRIUM

DEPARTURES TERMINALAC

D

E

F G H

I

J K L

G3

G4

G1

G2

G7

G8

G5

G6

ELEVATED ROADWAY

NORTH GARAGE SOUTH GARAGE

NOTES THIS SHEET

Revision

No. Date Description

1 7.23.24 ADDENDUM #1

1 1

1 1

.9

.5 .1

F G H H.

H.

2 J K

F G H J K

K.

K.

2 L

M N P Q R

0.

.5

.8

.8

.8

.8

.8

.5

.9

.7

.2

.5

.9

.9

.4

.2

.6

8.

6.

6.

K.

7.

.9

.5 .1

F G H H.

H.

2 J K

F G H J K

K.

K.

2 L

M N P Q R

0.

.5

.8

.8

.8

.8

.8

.5

.9

.7

.2

.5

.9

.9

.4

.2

.6

8.

6.

6.

K.

7.

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

/ 4

5 / 1 6"

3' 0"

5' 0"

55'-0" 55'-0" 55'-0" 55'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

5' 0"

55'-0"55'-0"55'-0"55'-0"55'-0"

12'-6"25'-0"12'-6"

55'-0"28'-0"24'-0"55'-0"55'-0" 3'-0"

K.

K.

2 L

M N P Q R

0.

.5

.8

.8

.8

.8

.8

.5

.9

.7

.2

.5

.9

.9

.4

.2

.6

8.

6.

6.

K.

7.

.9

.5 .1

F G H H.

H.

2 J K

F G H J K

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

5' 0"

55'-0"55'-0"55'-0"55'-0"55'-0"12'-6"25'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

/ 4

5 / 1 6"

3' 0"

5' 0"

55'-0" 55'-0" 55'-0" 55'-0"

55'-0"28'-0"24'-0"55'-0"55'-0" 3'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

/ 4

5 / 1 6"

3' 0"

5' 0"

55'-0" 55'-0" 55'-0" 55'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

5' 0"

55'-0"55'-0"55'-0"55'-0"55'-0"

12'-6"25'-0"12'-6"

55'-0"28'-0"24'-0"55'-0"55'-0" 3'-0"

VA

N

VA

N

.9

.5 .1

F G H H.

H.

2 J K

F G H J K

K.

K.

2 L

M N P Q R

0.

.5

.8

.8

.8

.8

.8

.5

.9

.7

.2

.5

.9

.9

.4

.2

.6

8.

6.

6.

K.

7.

.9

.5 .1

F G H H.

H.

2 J K

F G H J K

K.

K.

2 L

M N P Q R

0.

.5

.8

.8

.8

.8

.8

.5

.9

.7

.2

.5

.9

.9

.4

.2

.6

8.

6.

6.

K.

7.

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

/ 4

5 / 1 6"

3' 0"

5' 0"

55'-0" 55'-0" 55'-0" 55'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

5' 0"

55'-0"55'-0"55'-0"55'-0"55'-0"

12'-6"25'-0"12'-6"

55'-0"28'-0"24'-0"55'-0"55'-0" 3'-0"

K.

K.

2 L

M N P Q R

0.

.5

.8

.8

.8

.8

.8

.5

.9

.7

.2

.5

.9

.9

.4

.2

.6

8.

6.

6.

K.

7.

.9

.5 .1

F G H H.

H.

2 J K

F G H J K

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

5' 0"

55'-0"55'-0"55'-0"55'-0"55'-0"12'-6"25'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

/ 4

5 / 1 6"

3' 0"

5' 0"

55'-0" 55'-0" 55'-0" 55'-0"

55'-0"28'-0"24'-0"55'-0"55'-0" 3'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

/ 4

5 / 1 6"

3' 0"

5' 0"

55'-0" 55'-0" 55'-0" 55'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

5' 0"

55'-0"55'-0"55'-0"55'-0"55'-0"

12'-6"25'-0"12'-6"

55'-0"28'-0"24'-0"55'-0"55'-0" 3'-0"

VA

N

VA

N

SOUTH GARAGE HOURLY

PARKING

SOUTH GARAGE

EXPANSION

SOUTH GARAGE DAILY

PARKING

CONTRACTOR LAYDOWN AREA

D ra w n

By

C he ck ed

B y:

Ap pr ov ed

B y:

919 E Main Street Suite 1200

Richmond, VA 23219 804.788.0710

This Line is 3 Inches When Printed Full Size

IF

B

N U

M

BE

R

-2

7/

/2

:4 7:

A

M Au to de sk D oc s:

//R

IC

A irp or t R

/4

.4

Ar ch

C en tra lR

.rv t

Au th or

C he ck er

Ap pr ov er

R

IC

S O

U

TH

G

AR

AG

E

LI

G

H

TI

N G

R

EP

LA

C

EM

EN

T

NOT FOR

CONSTRUCTIO

N

OVERALL PHASING

PLAN - PHASE 1

A601 45533.46

06.17.2024

R

IC

H

AR

D

E B

YR

D

T

ER

M

IN

AL

D

R

R

IC

H M

O N

D , V

A

GreshamSmith.com

B

CONCOURSE A CONCOURSE B

ATRIUM

DEPARTURES TERMINALAC

D

E F

G H I

J K L

G3

G4

G1

G2

G7

G8

G5

G6

ELEVATED ROADWAY

NORTH GARAGE SOUTH GARAGE

PLAN

NORTH

0' 15' 60'30' 90' 1" = 30'-0"1 FIRST FLOOR REFLECTED CEILING PLAN PHASE-1

Revision No. Date Description 1 7/29/2024 Addendum #1

PHASE 1

NO WORK SHALL BEGIN UNTIL ALL FIXTURES ARE IN-HAND, EITHER ON SITE OR IN

CONTRACTOR'S WAREHOUSE.

BEGIN WORK ON MAIN DRIVE LANES (PHASE 1) AND PLACE BARRIERS SHOWN. AIRPORT WILL

BEGIN TO CLOSE SOUTH GARAGE HOURLY AND DAILY PARKING WHEN WORK ON PHASE 1

BEGINS.

PHASE 1 WORK MUST BE COMPLETE PRIOR TO BEGINNING PHASE 2 WORK.

ELIMINATE THE ADDITIONAL OFF-MODULE FIXTURES AT THE ENTRANCE TO THE GARAGES.

PHASE DURATIONS:

DRIVE LANES (3 TOTAL) - (7) CALENDAR DAYS - WORK TO BE PERFORMED FROM 7:00 PM TO 4:00 AM AND SHALL INCLUDE FLAG MEN. PHASE 1 AREAS WILL BE OPEN TO TRAFFIC AT ALL TIMES.

NORTH AND SOUTH LOBBY TOWERS (2 TOTAL) - WORK CAN BE PERFORMED AS FILLER WORK,

BUT ALL WORK SHALL BE COMPLETED BY 11/15/2024

CONTRACTOR LAYDOWN AREA:

CONTRACTOR TO PROTECT MATERIALS FROM WEATHER, PUBLIC TAMPERING AND FROM

THEFT. CONTRACTOR TO ALLOW 50% OF THE WIDTH OF THE WALKWAY OPEN TO THE PUBLIC.

SYMBOLS

PLACE WATER-FILLED BARRIER

PREVIOUSLY PLACED WATER-FILLED BARRIER

DO NOT ENTER SIGN TEMPORARILY AFFIXED TO BARRIER

.9

.5 .1

F G H H.

H.

2 J K

F G H J K

K.

K.

2 L

M N P Q R

0.

.5

.8

.8

.8

.8

.8

.5

.9

.7

.2

.5

.9

.9

.4

.2

.6

8.

6.

6.

K.

7.

.9

.5 .1

F G H H.

H.

2 J K

F G H J K

K.

K.

2 L

M N P Q R

0.

.5

.8

.8

.8

.8

.8

.5

.9

.7

.2

.5

.9

.9

.4

.2

.6

8.

6.

6.

K.

7.

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

/ 4

5 / 1 6"

3' 0"

5' 0"

55'-0" 55'-0" 55'-0" 55'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

5' 0"

55'-0"55'-0"55'-0"55'-0"55'-0"

12'-6"25'-0"12'-6"

55'-0"28'-0"24'-0"55'-0"55'-0" 3'-0"

K.

K.

2 L

M N P Q R

0.

.5

.8

.8

.8

.8

.8

.5

.9

.7

.2

.5

.9

.9

.4

.2

.6

8.

6.

6.

K.

7.

.9

.5 .1

F G H H.

H.

2 J K

F G H J K

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

5' 0"

55'-0"55'-0"55'-0"55'-0"55'-0"12'-6"25'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

/ 4

5 / 1 6"

3' 0"

5' 0"

55'-0" 55'-0" 55'-0" 55'-0"

55'-0"28'-0"24'-0"55'-0"55'-0" 3'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

/ 4

5 / 1 6"

3' 0"

5' 0"

55'-0" 55'-0" 55'-0" 55'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

5' 0"

55'-0"55'-0"55'-0"55'-0"55'-0"

12'-6"25'-0"12'-6"

55'-0"28'-0"24'-0"55'-0"55'-0" 3'-0"

VA

N

VA

N

.9

.5 .1

F G H H.

H.

2 J K

F G H J K

K.

K.

2 L

M N P Q R

0.

.5

.8

.8

.8

.8

.8

.5

.9

.7

.2

.5

.9

.9

.4

.2

.6

8.

6.

6.

K.

7.

.9

.5 .1

F G H H.

H.

2 J K

F G H J K

K.

K.

2 L

M N P Q R

0.

.5

.8

.8

.8

.8

.8

.5

.9

.7

.2

.5

.9

.9

.4

.2

.6

8.

6.

6.

K.

7.

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

/ 4

5 / 1 6"

3' 0"

5' 0"

55'-0" 55'-0" 55'-0" 55'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

5' 0"

55'-0"55'-0"55'-0"55'-0"55'-0"

12'-6"25'-0"12'-6"

55'-0"28'-0"24'-0"55'-0"55'-0" 3'-0"

K.

K.

2 L

M N P Q R

0.

.5

.8

.8

.8

.8

.8

.5

.9

.7

.2

.5

.9

.9

.4

.2

.6

8.

6.

6.

K.

7.

.9

.5 .1

F G H H.

H.

2 J K

F G H J K

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

5' 0"

55'-0"55'-0"55'-0"55'-0"55'-0"12'-6"25'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

/ 4

5 / 1 6"

3' 0"

5' 0"

55'-0" 55'-0" 55'-0" 55'-0"

55'-0"28'-0"24'-0"55'-0"55'-0" 3'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

/ 4

5 / 1 6"

3' 0"

5' 0"

55'-0" 55'-0" 55'-0" 55'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

5' 0"

55'-0"55'-0"55'-0"55'-0"55'-0"

12'-6"25'-0"12'-6"

55'-0"28'-0"24'-0"55'-0"55'-0" 3'-0"

VA

N

VA

N

.9

.5 .1

F G H H.

H.

2 J K

F G H J K

K.

K.

2 L

M N P Q R

0.

.5

.8

.8

.8

.8

.8

.5

.9

.7

.2

.5

.9

.9

.4

.2

.6

8.

6.

6.

K.

7.

.9

.5 .1

F G H H.

H.

2 J K

F G H J K

K.

K.

2 L

M N P Q R

0.

.5

.8

.8

.8

.8

.8

.5

.9

.7

.2

.5

.9

.9

.4

.2

.6

8.

6.

6.

K.

7.

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

/ 4

5 / 1 6"

3' 0"

5' 0"

55'-0" 55'-0" 55'-0" 55'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

5' 0"

55'-0"55'-0"55'-0"55'-0"55'-0"

12'-6"25'-0"12'-6"

55'-0"28'-0"24'-0"55'-0"55'-0" 3'-0"

K.

K.

2 L

M N P Q R

0.

.5

.8

.8

.8

.8

.8

.5

.9

.7

.2

.5

.9

.9

.4

.2

.6

8.

6.

6.

K.

7.

.9

.5 .1

F G H H.

H.

2 J K

F G H J K

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

5' 0"

55'-0"55'-0"55'-0"55'-0"55'-0"12'-6"25'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

/ 4

5 / 1 6"

3' 0"

5' 0"

55'-0" 55'-0" 55'-0" 55'-0"

55'-0"28'-0"24'-0"55'-0"55'-0" 3'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

/ 4

5 / 1 6"

3' 0"

5' 0"

55'-0" 55'-0" 55'-0" 55'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

5' 0"

55'-0"55'-0"55'-0"55'-0"55'-0"

12'-6"25'-0"12'-6"

55'-0"28'-0"24'-0"55'-0"55'-0" 3'-0"

VA

N

VA

N

.9

.5 .1

F G H H.

H.

2 J K

F G H J K

K.

K.

2 L

M N P Q R

0.

.5

.8

.8

.8

.8

.8

.5

.9

.7

.2

.5

.9

.9

.4

.2

.6

8.

6.

6.

K.

7.

.9

.5 .1

F G H H.

H.

2 J K

F G H J K

K.

K.

2 L

M N P Q R

0.

.5

.8

.8

.8

.8

.8

.5

.9

.7

.2

.5

.9

.9

.4

.2

.6

8.

6.

6.

K.

7.

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

/ 4

5 / 1 6"

3' 0"

5' 0"

55'-0" 55'-0" 55'-0" 55'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

5' 0"

55'-0"55'-0"55'-0"55'-0"55'-0"

12'-6"25'-0"12'-6"

55'-0"28'-0"24'-0"55'-0"55'-0" 3'-0"

K.

K.

2 L

M N P Q R

0.

.5

.8

.8

.8

.8

.8

.5

.9

.7

.2

.5

.9

.9

.4

.2

.6

8.

6.

6.

K.

7.

.9

.5 .1

F G H H.

H.

2 J K

F G H J K

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

5' 0"

55'-0"55'-0"55'-0"55'-0"55'-0"12'-6"25'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

/ 4

5 / 1 6"

3' 0"

5' 0"

55'-0" 55'-0" 55'-0" 55'-0"

55'-0"28'-0"24'-0"55'-0"55'-0" 3'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

/ 4

5 / 1 6"

3' 0"

5' 0"

55'-0" 55'-0" 55'-0" 55'-0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

0"

5' 0"

55'-0"55'-0"55'-0"55'-0"55'-0"

12'-6"25'-0"12'-6"

55'-0"28'-0"24'-0"55'-0"55'-0" 3'-0"

VA

N

VA

N

REMOVE LIGHTS

FROM PLANTERS

CONTRACTOR TO PROVIDE TEMP. STAIR CLOSURE SIGN.

PROVIDE 3 ADDITIONAL DETOUR SIGNS IDENTIFYING EXIT TO

STAIRS WITHIN GARAGE

ELIMINATE SURFACE

MOUNTED FIXTURES

CONTRACTOR TO PROVIDE TEMP. STAIR CLOSURE SIGN.

PROVIDE 3 ADDITIONAL DETOUR SIGNS IDENTIFYING EXIT TO

STAIRS WITHIN GARAGE

CONTRACTOR TO PROVIDE TEMP. STAIR CLOSURE SIGN.

PROVIDE 3 ADDITIONAL DETOUR SIGNS IDENTIFYING EXIT TO

STAIRS WITHIN GARAGE

CONTRACTOR TO PROVIDE TEMP. STAIR CLOSURE SIGN.

PROVIDE 3 ADDITIONAL DETOUR SIGNS IDENTIFYING EXIT TO

STAIRS WITHIN GARAGE

REPLACE ALL FIXTURES IN THE

UNDERSIDE OF THE ROOF

REPLACE ALL

FIXTURES IN THE

UNDERSIDE OF THE

ROOF

D ra w n

By

C he ck ed

B y:

Ap pr ov ed

B y:

919 E Main Street Suite 1200

Richmond, VA 23219 804.788.0710

This Line is 3 Inches When Printed Full Size

IF

B

N U

M

BE

R

-2

7/

/2

:4 7:

A

M Au to de sk D oc s:

//R

IC

A irp or t R

/4

.4

Ar ch

C en tra lR

.rv t

Au th or

C he ck er

Ap pr ov er

R

IC

S O

U

TH

G

AR

AG

E

LI

G

H

TI

N G

R

EP

LA

C

EM

EN

T

NOT FOR

CONSTRUCTIO

N

ELEVATOR ROOM

REFLECTED CEILING

PLANS

A606 45533.46

06.17.2024

R

IC

H

AR

D

E B

YR

D

T

ER

M

IN

AL

D

R

R

IC

H M

O N

D , V

A

GreshamSmith.com

0' 24'16'8'4' 1/8" = 1'-0"1 ELEVATOR ROOM FIRST FLOOR REFLECTED CEILING PLAN

0' 24'16'8'4' 1/8" = 1'-0"2 ELEVATOR ROOM SECOND FLOOR REFLECTED CEILING PLAN

0' 24'16'8'4' 1/8" = 1'-0"3 ELEVATOR ROOM THIRD FLOOR REFLECTED CEILING PLAN

0' 24'16'8'4' 1/8" = 1'-0"4 ELEVATOR ROOM FOURTH FLOOR REFLECTED CEILING PLAN

B

CONCOURSE A CONCOURSE B

ATRIUM

DEPARTURES TERMINALAC

D

E F

G H I

J K L

G3

G4

G1

G2

G7

G8

G5

G6

ELEVATED ROADWAY

NORTH GARAGE SOUTH GARAGE

Revision No. Date Description 1 7/29/2024 Addendum #1

Sheets
E001 - LEGEND, NOTES AND ABBREVIATIONS
E101 - FIRST FLOOR - LIGHTING PLAN - G5 GARAGE
E102 - FIRST FLOOR - LIGHTING PLAN - G6 GARAGE
E103 - FIRST FLOOR - LIGHTING PLAN - G7 GARAGE
E104 - FIRST FLOOR - LIGHTING PLAN - G8 GARAGE
E105 - NORTH & SOUTH GARAGE ELEVATOR ROOM LIGHTING PLANS
E801 - FIRST FLOOR - PHOTOMETRIC PLAN - G5 GARAGE
E802 - FIRST FLOOR - PHOTOMETRIC PLAN - G6 GARAGE
E803 - FIRST FLOOR - PHOTOMETRIC PLAN - G7 GARAGE
E804 - FIRST FLOOR - PHOTOMETRIC PLAN - G8 GARAGE
E805 - NORTH & SOUTH GARAGE ELEVATOR ROOM PHOTOMETRIC PLANS

File details come from the government source that posted it. Updated .