24-131.2 Radcliff_Bids Permits 2025-03-26.pdf
PDF 11 MB Posted
- Attached to
- Radcliff Center - ADA Bathroom Renovation
- Solicitation number
- 2025-04-11-1100
- Issued by
- Wayne County, Forest Hills CDP, Michigan
About this file
This is a comprehensive architectural and engineering design package for the City of Garden City's Radcliff Center Toilet Room Upgrades - Group #2 project located at 1751 Radcliff St. in Garden City, Michigan. The project involves renovating existing toilet rooms in the Radcliff Center, including new plumbing fixtures, additional fixtures, LED lighting, expansion of the women's room, and new finishes. The design documents include detailed architectural plans, mechanical and plumbing specifications, demolition plans, floor plans, interior elevations, and accessibility requirement details. An alternate bid option allows for cost reduction by omitting ceramic/porcelain tile and instead painting existing CMU walls and new construction in 2-3 colors.
The project is funded by the City of Garden City and is set to be bid on March 26, 2025, with bids due on April 11, 2025 at 11:00 AM. The total project area involves multiple toilet room groups, with specific focus on improving accessibility and modernizing the facilities. Plumbing fixture calculations indicate upgrades to multiple toilet groups, adjusting the number of water closets and lavatories. The design emphasizes ADA compliance, with detailed specifications for fixture placement, clearances, and accessibility features. The architectural team (Detroit Architectural Group) and mechanical engineer (JRED Engineering) have prepared comprehensive documentation that includes specific requirements for materials, installation methods, and system performance standards.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G-001
TITLE SHEET
MV
BK
BK
This drawing is an instrument of service, remains the property of Detroit Architectural Group, Inc. Any changes, publication, or unauthorized use is prohibited unless expressly approved.
24-131.2
SHEET NO:
JOB NO:
SHEET NAME:
IN CHARGE:
CHECKED BY:
DRAWN BY:
SEAL:
REV DATE ISSUED
ENGINEERING, INC.
25041
JRED PROJECT NUMBER:
Consulting Engineers 14115 Farmington Rd., Ste. 100 Livonia, MI 48154 Tel: (734) 855-4904 email: esteban@jredengineering.com
CITY OF
GARDEN CITY -
RADCLIFF
CENTER
Proposed Toilet Room Upgrades
- Group #2 -
1751 RADCLIFF ST.
GARDEN CITY, MI 48135
TITLE SHEET & GENERAL INFORMATIONG-001
A-101
G-002 ACCESSIBILITY REQUIREMENTS, NOTES AND DETAILS
G-003 PLUMBING FIXTURE CALCULATIONS AND LIFE SAFETY PLAN
OWNER
CITY OF GARDEN CITY
6000 MIDDLEBELT RD.
GARDEN CITY, MI 48135
CONTACT: ERIKA SMITH
(734) 793-1878 erikas@gardencitymi.org
ARCHITECT OF RECORD
DETROIT ARCHITECTURAL GROUP
1644 FORD RD.
WYANDOTTE, MI 48192
CONTACT: BRANDON KRITZMAN
(734) 556-3259 office
(313) 690-1299 mobile bkritzman@detroitarch.com
CONTRACTOR
T.B.D.
ARCHITECTURAL
A-601
PROJECT
LOCATION
A-401
DEMOLITION AND PROPOSED FLOOR PLANS
DOOR AND ROOM FINISH SCHEDULE AND NOTES
INTERIOR ELEVATIONS
INDEX OF DRAWINGS
DESCRIPTIONSHEET
1751 Radcliff St.
Garden City, MI 48135
PROPOSED
TOILET ROOM UPGRADES - GROUP 2 -
CITY OF GARDEN CITY - RADCLIFF CENTER
MECHANICAL ENGINEER
JRED ENGINEERING, INC.
14115 FARMINGTON RD STE 100
LIVONIA, MI 48154
CONTACT: JOSE CABELLO, PE
(313) 348-2166 jose@jredengineering.com
GENERAL NOTES CONTACTS
NEW WALL
SYMBOLS AND CONVENTIONS
ABBREVIATIONS
INTERIOR ELEVATION (MULTIPLE):
ELEVATION LEVEL:
EXTERIOR & INTERIOR ELEVATION:
DETAIL CALLOUT:
BUILDING SECTION:
WALL SECTION:
DETAIL PLAN OR ELEVATION:
REVISION:
REVISION CLOUD:
KEYNOTE:
NEW GRID LINES:
EXISTING GRID LINES:
WINDOW TAG:
XX
INTERIOR ROOM FINISH TAG:
INDICATES CEILING FINISH
INDICATES WALL FINISH
INDICATES BASE FINISH
INDICATES FLOOR FINISH
FLOOR (DOOR) TRANSITION TAG:
INDICATES FLOOR FINISH
WALL
INTERIOR ROOM FINISH TAG:
INDICATES WALL FINISH
X X
X X
FINISH PATTERN OR GRAIN TAG:
INDICATES FINISH DIRECTION
SEE CORRESPONDING
NUMBERED KEY NOTE ON SHEET
WHERE REFERENCE OCCURS
REVISION NUMBER - SEE
REVISION HISTORY ON TITLE
BLOCK OF EACH SHEET
INDICATES
FLOOR LEVEL
INDICATES FLOOR
LEVEL ELEVATION
ROOM NAME
ROOM NUMBER
REVISION NUMBER - SEE
REVISION HISTORY ON TITLE
BLOCK OF EACH SHEET
WALL TAG:
EXISTING WALL TO REMAIN
EXISTING WALL TO BE REMOVED
LOCATION MAP
ABOVE
ANCHOR BOLT
ACOUSTICAL CEILING TILE
AIR CONDITIONING
ABBREVIATION(S)
ACOUSTIC
AREA DRAIN
ANODIZED
APPROVED
ALUMINUM
ABOVE FINISH FLOOR
ARCHITECTURAL
AB.
A/C
A.B.
A.C.T.
ABBREV.
A.D.
A.F.F.
ACOUST.
ARCH.
ANOD.
APPVD.
ALUM.
BLOCK
BUILDING
BOARD
BEAM
BOTTOM
BOTTOM OF STEEL
BD.
BLK.
BLDG.
BM.
BOTT.
B.O.S.
CEMENT
CERAMIC
CLEAR
CEILING
CONTROL JOINT
CONCRETE MASONRY UNIT
CENTER TO CENTER
CONTINUOUS
CONCRETE
CORRIDOR
CARPET
COMPOSITION
CERAMIC TILE
DOUBLE
DIAMETER
DETAIL
DOWN
DIMENSION
DIRECTION
DIAGONAL
COLUMN
C/C
CEM.
CER.
C.M.U.
CLG./CEIL.
CLR.
C.J.
COMP.
CONT.
CONC.
C.T.
CORR.
CPT.
DIA.
DBL.
DET.
DN.
DIM.
DIR.
DIAG.
COL.
DOOR OPENINGD.O.
F.O.M.
F.O.C.
F.O.F.
F.O.
F.S.
FT.
F.O.S.
F.R.P.
GA.
GALV. GALVANIZED
FLOOR SINK
FEET
GAUGE
G.F.R.C.
G.F.R.G.
GYPSUM
CONCRETE
GL. GLASS
DOOR
DRAWING
DOWNSPOUT
EACH
DRAWER
ROOM
ELECTRICAL
EMERGENCY
ELEVATOR
ENGINEER
ELEVATION
ELECTRONIC EQUIPMENT
EXISTING
EQUIPMENT
EXTERIOR
EACH WAY
EXPANSION
ELECTRIC WATER COOLER
FINISH
FLOOR
FINISH FLOOR
FLOOR DRAIN
FIRE HOSE CABINET
EXPANSION JOINT
D.S.
DR.
DWG.
EA.
DWR.
E.E.R.
ELEC.
EMERG.
ELEV.
ENGR.
ELEV./EL.
EQUIP.
EX'G.
EXT.
E.W.
E.W.C.
EXP.
F.F.
FIN.
F.H.C.
FLR.
F.D.
E.J.
FACE OF CONCRETE
FINISHED OPENING
GLASS FIBER REINFORCED
GLASS FIBER REINFORCED
FIBER REINFORCED PLASTIC
FACE OF STUD
FACE OF MASONRY
FACE OF FINISH
GR.
GYP. BD.
GRADE
H.
H.B.
H/C
H.M.
HORIZ.
HDWD. HARDWOOD
HANDICAP
HORIZONTAL
HIGH
HOSE BIB
G.W.B.
HPL
HVAC
I.D.
IN.
HYD.
INCHES
HYDRANT
I.W.
INT.
JT.
JST.
JAN.
JOINT
JOIST
JANITOR
INTERIOR
INSULATIONINSUL.
HGT. HEIGHT
LTG.
LAV.
LAM.
LVL.
LTWT.
LAVATORY
LIGHTWEIGHT
LEVEL
LIGHTING
LAMINATE
MAX.
MAINT.
MATL.
MET.
MEZZ.
MECH.
M.B.
MAINTENANCE
MEZZANINE
MECHANICAL
MAXIMUM
METAL
MATERIAL
MFR.
HIGH PRESSURE LAMINATE
GYPSUM BOARD
INSIDE DIAMETER
HEATING VENTILATION
HOLLOW METAL
INDIRECT WASTE
MANUFACTURER
MACHINE BOLT
GYPSUM WALL BOARD
AIR CONDITIONING
OFFICE
OWNER FURNISH ITEM
INSTALL
OPPOSITE
OPENING
OVERHEAD
CONTRACTOR INSTALL
PRESSURE TREATED
PLYWOOD
OFF.
OFCI
OFI
OFOI
O.H.
OPP.
P.T.
PWD.
OPN'G.
OWNER FURNISH
OWNER FURNISH OWNER
RADIUS
RISER
REFERENCE
ROOF DRAIN
QUARRY TILE
ROOM
REINFORCED
REFLECTED
REQUIRED
RESILIENT
ROOF SUMP
ROUGH OPENING
Q.T.
REF.
RAD.
R.D.
R.
REQ'D.
REINF.
REFL.
RM.
R.S.
R.O.
RES.
ROOF CONDUCTORR.C.
M.O.
MIN.
MISC.
N.I.C.
MULL. MULLION
MINIMUM
NON-COM
N.T.S.
NOM.
O.D.
O.C.
O.C.C.
ON CENTER
NOMINAL
NO. NUMBER
OVERFLOWO.F.
NOT IN CONTRACT
MASONRY OPENING
MISCELLANEOUS
NON-COMBUSTIBLE
OUTSIDE DIAMETER
OPERATOR CONTROL CENTER
NOT TO SCALE
SHEET
SECTION
SIMULATED
SIMILAR
SQUARE FOOT
SOLID CORE
STANDARD
STATION
SYMMETRICAL
SUSPENDED
STRUCTURAL
STAINLESS STEEL
SPECIFICATIONS
SECT.
S.C.
SIMUL.
S.F.
SHT.
SIM.
SPEC.
S.S.
STA.
STRUCT.
SYM.
SUSP.
STD.
TREAD
THICK
TEMPERED
TELEPHONE
TOP AND BOTTOM
TYPICAL
TOP OF WALL
TOP OF STEEL
TOP OF MASONRY
TOP OF PARAPET
TOP OF CONCRETE
T.
T. & B.
TH.
TEMP.
TEL.
T. & G.
T.O.P.
T.O.C.
T.O.M.
T.O.W.
TYP.
T.O.S.
URINAL
VESTIBULE
VERTICAL
WIDE
WITH
WOOD
WITHOUT
WROUGHT IRON
WATER CLOSET
U.N.O.
UR.
VCT
VEST.
VERT.
W.
W.C.
W/
W.I.
WD.
W/O
VINYL COMPOSITION TILE
UNLESS NOTED OTHERWISE
TONGUE AND GROOVE
WEATHERPROOFWP
SURFACED FOUR SIDESS4S
INDICATES SHEET WHERE
DETAIL CALLOUT IS DRAWN
INDICATES INTERIOR
ELEVATION NUMBER
INDICATES SHEET
WHERE INTERIOR
ELEVATION IS DRAWN
X
X
X
X
X
X
INDICATES WALL TYPE
EXISTING
NORTH
EXISTING DOOR TO REMAIN
PROPOSED DOOR
EXISTING DOOR TO BE REMOVED
DETAIL IDENTIFICATION
NUMBER(S)
(SAME NUMBER ON ON SHEET
WHERE DRAWN)
PLAN OR SECTION DETAIL
IDENTIFICATION NUMBER
(SAME NUMBER ON SHEET
WHERE DRAWN)
SHEET IDENTIFICATION
NUMBER (INDICATES SHEET
WHERE SECTION DETAIL IS
DRAWN)
SECTION DETAIL
IDENTIFICATION NUMBER
(SAME NUMBER ON SHEET
WHERE DRAWN)
SHEET IDENTIFICATION
NUMBER (INDICATES SHEET
WHERE SECTION DETAIL IS
DRAWN)
WALL SECTION IDENTIFICATION
NUMBER (SAME NUMBER ON
SHEET WHERE DRAWN)
SHEET IDENTIFICATION NUMBER
(INDICATES SHEET WHERE WALL
SECTION IS DRAWN)
ELEVATION IDENTIFICATION
NUMBER(S) INDICATES
DIRECTION OF VIEW OR VIEWS
(SAME NUMBER ON ON SHEET
WHERE DRAWN)
SHEET IDENTIFICATION
NUMBER (INDICATES SHEET
NUMBER WHERE ELEVATION IS
DRAWN)
X-XXX
X
X-XXX
X
DOOR NUMBER -
REFER TO SCHEDULE
WINDOW DESIGNATION -
REFER TO FLOOR PLANS
DOOR TAG:
X
X-XXX
X
X-XXX
X
X-XXX
X
X
X
X X
X
DEFERRED SUBMITTALS
SCOPE OF WORK
RENOVATION OF EXISTING TOILET ROOMS,
INCLUDING NEW PLUMBING FIXTURES,
ADDITIONAL FIXTURES, LED LIGHTING,
EXPANSION (WOMEN'S ROOM ONLY) AND
NEW FINISHES.
ALTERNATE 01: AS AN ALTERNATE PLEASE
SUBMIT COST REDUCTION FOR OMITTING
THE CERAMIC/PORCELAIN TILE AND
PAINTING THE EXISTING CMU WALLS AND
NEW CONSTRUCTION PER THE FINISH
SCHEDULE (2-3 COLORS)
1. ALL DRAWINGS AND THE NOTATIONS SHALL APPLY TO THE WORK OF THIS PROJECT AND SHALL BE CAREFULLY REVIEWED BY EACH CONTRACTOR AND EACH CONTRACTOR SHALL COORDINATE HIS WORK WITH WORK OF ALL OTHER CONTRACTORS. THE GENERAL
NOTES SHALL APPLY TO EACH CONTRACTOR.
2. CONTRACTOR IS RESPONSIBLE TO CONFORM WITH APPLICABLE FEDERAL, STATE, AND LOCAL CODES AND REGULATIONS
INCLUDING APPLICABLE ORDINANCES AND REFERENCED STANDARDS.
3. REFER TO DRAWINGS OF EACH TRADE OR DISCIPLINE FOR ADDITIONAL GENERAL NOTES AND INFORMATION, INCLUDING CIVIL/SITE DEVELOPMENT, ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION, AND ELECTRICAL.
4. THESE DRAWINGS SHALL NOT BE SCALED TO OBTAIN DIMENSIONS. IF THE DIMENSIONS CANNOT BE DETERMINED BY THE INFORMATION GIVEN, CONTRACTOR SHALL REQUEST CLARIFICATION FROM THE ARCHITECT. ALL DIMENSIONS ARE TO FACE OF STUD, FACE OF CMU, OR FACE OF CONCRETE, UNLESS NOTED OTHERWISE. CEILING HEIGHT DIMENSIONS ARE FROM FINISHED
FLOOR TO FACE OF FINISHED CEILING MATERIALS, UNLESS NOTED OTHERWISE.
5. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR SAFETY PRECAUTIONS AND SHALL COMPLY WITH THE REQUIREMENTS OF O.S.H.A., ALL APPLICABLE BUILDING CODES, AND ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION INSOFAR AS APPLICABLE TO HIS PORTION OF THE WORK.
6. ALL MATERIALS SHALL BE NEW AS CALLED FOR IN THE NOTES AND DRAWINGS. NO SUBSTITUTIONS SHALL BE MADE BY CONTRACTORS WITHOUT THE PRIOR WRITTEN APPROVAL OF THE GENERAL CONTRACTOR. SUBSTITUTIONS OR 'APPROVED EQUAL' PRODUCTS SHALL BE LISTED AND APPROVED BY THE ARCHITECT PRIOR TO CONTRACT SIGNING. ALL MATERIALS SHALL BE ORDERED IN A TIMELY FASHION AND WILL NOT CONSTITUTE REASON FOR SUBSTITUTION. DELAYS FOR MATERIALS WILL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR FOR PORTIONS OF THE WORK NOT SHOWN ON DETAIL, BUT WHICH ARE SHOWN GENERALLY, OR ARE REASONABLY INFERABLE AS BEING REQUIRED FOR A PROPER AND COMPLETE INSTALLATION. THE MATERIALS, METHODS, AND WORKMANSHIP SHALL CONFORM AS A MINIMUM TO THE TYPICAL OR REPRESENTATIVE DETAIL
THROUGHOUT CORRESPONDING PARTS OF THE BUILDING.
7. EACH CONTRACTOR OR PARTY ENGAGED ON THE PROJECT SHALL CARRY WORKER'S COMPENSATION INSURANCE IN STATUTORY AMOUNTS, LIABILITY, BODILY INJURY, AUTOMOBILE, AND OTHER INSURANCE IN THE AMOUNTS AND FOR PERIODS SATISFACTORY TO THE GENERAL CONTRACTOR. CERTIFICATIONS OF INSURANCE SHALL BE SUBMITTED BEFORE COMMENCING WORK. FIRE INSURANCE WILL BE CARRIED BY THE GENERAL CONTRACTOR TO THE FULLEST EXTENT PERMITTED BY LAW RELATIVE TO PROJECT.
CONTRACTORS, SUBCONTRACTORS AND ALL PARTIES ENGAGED IN THE PORTIONS OF THE WORK SHALL INDEMNIFY AND HOLD HARMLESS THE GENERAL CONTRACTOR AND ARCHITECT AND HIS CONSULTING ENGINEERS AND THEIR AGENTS AND EMPLOYEES FROM AND AGAINST ALL CLAIMS, DAMAGES, LOSSES, INCLUDING DEATH AND EXPENSES. INCLUDING BUT NOT LIMITED TO
ATTORNEY'S FEES ARISING OUT OF OR RESULTING FROM THE PERFORMANCE OF THE WORK.
8. EACH CONTRACTOR SHALL MAKE ALL ARRANGEMENTS FOR, OBTAIN AND PAY FOR ALL PERMITS, TESTS, INSPECTIONS AND
APPROVALS REQUIRED FOR HIS PORTION OF THE WORK.
9. ARRANGEMENTS AND PAYMENT FOR TEMPORARY ELECTRICITY, WATER, TOILET FACILITIES, FENCING AND BARRICADES, SECURITY, AND CLEANUP WILL BE AS AGREED UPON IN THE AGREEMENTS BETWEEN GENERAL CONTRACTOR AND CONTRACTOR.
10. LOCATION OF ALL TEMPORARY FACILITIES SHALL BE COORDINATED WITH OWNER AND ARCHITECT PRIOR TO MOBILIZATION ON-SITE, INCLUDING BUT NOT LIMITED TO TEMPORARY STAGING AREA, MATERIAL STORAGE AREA, ACCESS DRIVE(S), PARKING AREA, TOPSOIL STOCKPILE AREA, WASTE DISPOSAL AREA, FIELD OFFICES AND TEMPORARY FACILITIES, JOB SIGN, AND
TEMPORARY FENCING.
11. SPECIFIC WORK ITEMS SHALL BE COORDINATED AND INTERFACED WITH ALL OTHER TRADES TO ALLOW FOR NEW CONSTRUCTION
AND COMPLETE INSTALLATION AS REQUIRED TO ACCOMPLISH DESIGN INTENT.
12. EQUIPMENT AND DEVICES OF A TEMPORARY NATURE REQUIRED FOR THE CONSTRUCTION PROCESS AND FOR THE PROTECTION OF THE WORKERS ENGAGED ON THE PROJECT AND FOR THE PUBLIC (SCAFFOLDS, STAGING, PLATFORMS, RUNWAYS, HOISTS, GUARDS, RAILINGS, OPENING PROTECTIVE, ETC.) SHALL BE PROVIDED, ERECTED, AND MAINTAINED BY THE VARIOUS CONTRACTORS IN ACCORDANCE WITH ALL APPLICABLE BUILDING CODES. CONTRACTORS SHALL OBTAIN AND PAY FOR THE REQUISITE PERMITS, INSPECTIONS, AND APPROVALS THEREOF. ALL SUCH ITEMS SHALL BE REMOVED BY CONTRACTORS WHEN
ITEMS HAVE SERVED THEIR PURPOSE AND WHEN DIRECTED BY THE GENERAL CONTRACTOR.
13. CONTRACTOR TO PROTECT ALL ITEMS WITHIN THE CONSTRUCTION LIMITS (INCLUDING SITE ELEMENTS) THAT ARE DESIGNATED TO REMAIN; ITEMS DAMAGED AS A RESULT OF WORK PERFORMED UNDER THIS CONTRACT SHALL BE REPAIRED OR REPLACED TO
ORIGINAL CONDITION.
14. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR ANY CUTTING, FITTING AND PATCHING THAT MAY BE REQUIRED TO COMPLETE
THE WORK OF HIS CONTRACT.
15. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO SUBMITTING A BID OR BEGINNING ANY WORK. CONDITIONS FOUND TO BE IN VARIANCE FROM THE INFORMATION IN THE DRAWINGS OR PROJECT
MANUAL SHALL BE SUBMITTED TO THE ARCHITECT IN WRITING FOR CLARIFICATION.
16. FIELD VERIFY ACTUAL LOCATIONS OF EXISTING UNDERGROUND UTILITIES, STRUCTURES, WATER LINES, STORM AND SANITARY LINES, GAS LINES, ELECTRICAL CONDUIT, AND OTHER UNDERGROUND UTILITIES PRIOR TO PERFORMING EARTHWORK, EXCAVATION, OR UTILITY WORK. ENGAGE THE SERVICES OF A PRIVATE UTILITY LOCATE COMPANY IF NECESSARY TO COMPLETELY
LOCATE EXISTING UNDERGROUND UTILITIES AND STRUCTURES.
17. ANY CONTRACTOR IS TO STOP WORK IMMEDIATELY IN AREA IF ABATEMENT MATERIAL(S) ARE ENCOUNTERED. NOTIFY GENERAL CONTRACTOR OF SUSPECTED AREA SO PROPER ABATEMENT CAN BE DONE. (UNDER A SEPARATE ABATEMENT CONTRACT AS
NEGOTIATED BY OWNER.)
18. SHOULD ANY CONTRACTOR HAVE THE OPINION THAT THERE EXIST IN THE DRAWINGS ANY ERRORS OR DISCREPANCIES, OR THAT CONDITIONS OF THE WORK OF ANY OTHER CONTRACTOR IS SUCH AS WILL PREVENT HIM FROM COMPLETING HIS WORK IN A FIRST-CLASS MANNER, HE SHALL NOTIFY THE GENERAL CONTRACTOR BEFORE PROCEEDING WITH THE WORK. THE GENERAL CONTRACTOR SHALL DIRECT ANY DISCREPANCIES TO THE ARCHITECT PRIOR TO CONSTRUCTION AND SHALL BE RESPONSIBLE FOR
WORK WHICH PROCEEDS WITHOUT DUE COURSE AND COORDINATION.
19. ALL WORK SHALL BE GUARANTEED FOR A PERIOD OF AT LEAST ONE YEAR FROM THE DATE OF ACCEPTANCE.
20. CARPENTRY WORK SHALL CONSIST, IN GENERAL, OF WORK AS SHOWN INCLUDING BUT NOT LIMITED TO THE WALLS, ROOFS, SHEATHING, WOOD TRIM (BOTH INTERIOR AND EXTERIOR) INTERIOR STUDDING FOR PARTITIONS, STAIRS, DOORS AND APPLICATION OF HARDWARE. ALL SIZES, TYPES, DETAILS AND SPECIES AS SHOWN. INSTALL ALL MEMBERS AS SHOWN IN PROPER LOCATIONS PLUMB AND TRUE TO LEVEL. SECURELY FASTEN AND ANCHOR WALLS TO THE CONCRETE STRUCTURE AND ALL MEMBERS TO EACH OTHER TO PROVIDE FULL STRENGTH AT JOINTS USING PROPER AND SUFFICIENT FASTENING IN ORDER TO ENSURE RIGIDITY OF THE STRUCTURE AND CONFORMITY TO CODE. PROVIDE BACKING/BRACING FOR ALL PLUMBING FIXTURES, PARTITIONS, GRAB BARS, OR OTHER FINISH ELEMENTS THAT PROVIDE SECURED POSITIONING TO PARTITIONS
21. CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL MISCELLANEOUS BLOCKING REQUIRED FOR INSTALLATION OF ALL BUILDING COMPONENTS, INCLUDING BUT NOT LIMITED TO FURNISHINGS, FIXTURES, EQUIPMENT, HARDWARE, BRACKETS, AND OWNER-PROVIDED EQUIPMENT. CONTRACTOR SHALL COORDINATE SPECIFIC REQUIREMENTS ASSOCIATED WITH EACH TRADE
AND WITH OWNER'S REPRESENTATIVE.
22. CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL MISCELLANEOUS WOOD AND METAL TRIM, FLASHING, CLIP ANGLES, ANCHORS, SUPPORTS, AND CLOSURE TRIM REQUIRED TO PROVIDE A COMPLETE, UNIFORM, AND WEATHER-TIGHT ASSEMBLY AS REQUIRED
TO ACCOMPLISH THE DESIGN INTENT.
23. ALL NEW DOORS REQUIRED TO BE ACCESSIBLE SHALL HAVE HARDWARE HEIGHT FROM 34 INCHES TO 48 INCHES PER SECTION 1008.1.9.1.
24. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS, CONTRACTOR SHALL PROVIDE AND INSTALL ALL ACCESSORY COMPONENTS AS REQUIRED TO FULLY COMPLY WITH MANUFACTURER'S
RECOMMENDATIONS.
25. CONTRACTOR SHALL PROVIDE ACCESS DOORS IN ALL WALLS AND CEILINGS WHERE SERVICE OR ADJUSTMENT TO MECHANICAL, PLUMBING, FIRE PROTECTION, OR ELECTRICAL ITEMS MAY BE REQUIRED. ACCESS DOORS SHALL BE OF AN APPROPRIATE SIZE REQUIRED FOR EACH APPLICATION. WHERE APPLICABLE, ACCESS DOORS SHALL MATCH THE FIRE RATING OF THE WALL
ASSEMBLY.
26. CONTRACTOR SHALL SEAL ALL PENETRATIONS IN EXTERIOR WALL AND ROOF ASSEMBLIES WITH APPROPRIATE JOINT SEALANT(S) AND FLASHING(S) TO MAINTAIN A WEATHER-TIGHT AND AIRTIGHT BUILDING ENVELOPE. ALL JOINTS AND PENETRATIONS SHALL BE SEALED, GASKETED, OR WEATHER-STRIPPED TO MINIMIZE AIR LEAKAGE, INCLUDING THE FOLLOWING:
A. JOINTS AROUND FENESTRATION AND DOOR FRAMES.
B. JUNCTIONS BETWEEN WALLS AND FOUNDATIONS, BETWEEN WALLS AT BUILDING CORNERS, BETWEEN WALLS AND
FLOORS OR ROOFS, AND BETWEEN WALLS AND ROOF OR WALL PANELS.
C. OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH ROOFS, WALLS, AND FLOORS.
D. JOINTS, SEAMS, AND PENETRATIONS OF VAPOR RETARDERS.
E. ALL OTHER OPENINGS IN THE BUILDING ENVELOPE.
27. ALL PENETRATIONS AND JOINTS IN FIRE-RATED WALL ASSEMBLIES AND FLOOR/CEILING ASSEMBLIES SHALL BE SEALED WITH THE FIRESTOPPING SYSTEM OR FIRE-RESISTIVE JOINT SYSTEM WHICH IS THE MOST APPROPRIATE FOR THE SPECIFIC APPLICATION BASED ON THE TYPE OF ASSEMBLY AND TYPE OF PENETRATING ELEMENT. SYSTEMS SHALL BE U.L.-LISTED FOR EACH APPLICATION.
28. ALL VERTICAL FENESTRATION (OPERABLE AND FIXED GLAZED ASSEMBLIES) SHALL BE LABELED BY THE MANUFACTURER WITH U-FACTOR, SHGC RATING, SAFETY RATING, AND FIRE-RESISTANCE RATING, WHERE APPLICABLE. WINDOWS AND DOORS SHALL BE
CERTIFIED AS MEETING AIR LEAKAGE REQUIREMENTS PER NFRC 400.
ROOM TAG:
X
A-102 REFLECTED CEILING AND ROOM FINISH PLANS
MECHANICAL/PLUMBING
MP-000 MECHANICAL & PLUMBING COVER SHEET
MP-100 MECHANICAL & PLUMBING PLANS
MP-200 MECHANICAL & PLUMBING DETAILS, DIAGRAMS, AND SCHEDULES
MP-300 MECHANICAL & PLUMBING SPECIFICATIONS
MP-301 MECHANICAL & PLUMBING SPECIFICATIONS
-2
5-
BI
D S
PE
R M
IT
S
BIDS & PERMITS03-26-25
A-402 INTERIOR ELEVATIONS
4'-0"
BLOCKING AS
REQUIRED
SHELVE
5/8" WR GYP BD UP TO
START OF SHELVES
SINGLE LEVER, SINGLE
HOLE MOUNT SINK FAUCET.
SEALANT
5 1/2" DEEP ADA ACCESSIBLE SINK
HOLE AND SINK
OPEN AREA BELOW SINK FOR ADA
COMPLIANCE
PROTECTIVE
INSULATION WRAP AT
WATER AND DRAIN
LINES BELOW SINK
BASE AS
SCHEDULED
PARTITION AS
SPECIFIED
5' -0
NOTE: iF X>24", THEN AN
ADDITIONAL MANEUVERING
CLEARANCE OF 6" SHALL BE
PROVIDED AS SHOWN
NOTE: iF X>15", THEN AN
ADDITIONAL MANEUVERING
CLEARANCE OF 12" SHALL BE
PROVIDED AS SHOWN
FIG. 38 STORAGE SHELVES AND CLOSETS
FIG. 26 TWO HINGED
DOORS IN SERIES
WALKING
PERPENDICULAR
TO A WALL
(b) ALTERNATE STALLS(a) STANDARD STALL
STANDARD STALL
(END OF ROW)
(a) HIGH FORWARD REACH LIMIT
(c)
PARALLEL
APPROACH
(a)
CLEAR FLOOR
SPACE
(b)
TURNS AROUND AN
OBSTRUCTION
(a)
90° TURN
(d) SIDE WALLS
(c) REAR WALL OF
STANDARD STALL
FIG. 56 STACKS
NOTE: X<24" NOTE: X<15"
NOTE: Y=48" MIN. IF
DOOR HAS CLOSER
SEAT
WALL
(a) 36" BY 36" STALL
BACK CONTROL WALLSEAT WALL
(B) CLOSETS(A) SHELVES
FOOT BACK HEAD
(a) 36" BY
36" STALL
SEAT
(a) PROPORTIONS
INTERNATIONAL SYMBOL
OF ACCESSIBILLITYINTERNATIONAL TDD SYMBOL
INTERNATIONAL SYMBOL OF
ACCESS FOR HEARING LOSS
FIG 43. INTERNATIONAL
SYMBOLS
ELEVATION
THIS OVERHANG CAN BE
GREATER THAN 12"
BECAUSE NI\O ONE CAN
APPROACH THE OBJECT
FROM THIS DIRECTION
CONTROL
AREA
CLEAR FLOOR
SPACE
(a) FRONT APPROACHES-SWINGING
DOORS
(c) HING SIDE APPROACHES-SWINGING
DOORS
NOTE: IF Y=60", THEN X=36"
IF Y=54", THEN X=42"
PULL SIDE
EDGE PROTECTION
PROVIDED BY VERTICAL
GUARD RAILS
NOTE: ALL DOORS IN ALCOVES SHALL
COMPLY WITH THE CLEARANCES FOR
FRONT APPROACHES
FIG. 36 SHOWER
SEAT DESIGN
SIDE
36" MIN.
" M
IN
3' MIN.
18" MIN. 18" MIN.
" M
IN
CLEAR
FLOOR
SPACE
4' MIN.
4' MIN.
" M
IN
3' MIN.
18" MIN. 18" MIN. 18" MIN.42"
" M
IN
1.5" 0 RAIL
(SS OR CHROME)
12" 3'-6"
3' MAX
" M
IN
4' MIN.
3'-0"
12" MAX.
6"
1'-6"
5'-0" (60")
5' -0
5'-0"
SIZE AND SPACING OF HANDRAILS AND GRAB BARS
32"
" M
AX
" M
IN
" M
AX
12" MAX
GR
EA
TE
R
TH
AN
7"
" M
IN
" M
IN
54" MIN.
2' MIN.
" M
IN
Y
X
24" PREFERED
18" MIN
2' MIN.
" M
IN
" M
IN
Y
54" MIN.
PUSH
SIDE
" M
IN
Y
2' MIN.
PUSH
SIDE
" M
IN
X
" M
AX
(c) LATCH SIDE APPROACHES-SWINGING
DOORS
3' MIN. 4' MIN. 3' MIN.
3'-6"
WHEN X < 4'
3'-6"
WHEN X < 4'X
4' W
HE
N
X <4
21" MAX.
9" M
IN
9" M
IN
2' MIN. 2' MAX.
4' MIN. 15" MAX.
" 9"
27" MAX
" M
IN
" M
IN
60" MIN.
48" MIN.
" M
IN
3' C
O N
TR
O
L W
AL
L
3' CONTROL
WALL
3' C
O N
TR
O
L W
AL
L
16" MAX.
1.5"
MAX.
12" MIN.
" M
AX
23" MIN.
1.
5"
M
AX
M
AX
M
AX
SEAT
WALL
M
AX
M
AX
CONTROL
AREA
18"
1' -6
27" MAX.
27" MAX.
AD
JU
ST
AB
LE
R
AN
GE
M
AX
75" MIN.
" M
IN
. CLEAR
FLOOR
SPACE
60" MIN.
" M
IN
60" MIN.
" M
IN
6' -8
" M
IN
4" MAX.
M
AX
2' MIN.
OBJECTS
MOUNTED ON
POSTS OR PYLONS
30" MIN.
2' MIN.12" MAX.
9"
1' MAX.
15"
CLEAR WIDTH ANY AMOUNT
" M
AX
" M
IN
" M
IN
CANE
RANGE
4' M
IN
5'-0" 6" 12" 2' 1'-6"
3' -4
5' -0
3'
M
IN
" M
IN
5'-0" 6" 12" 2' 1'-6"
4' MIN.
3' -4
8"
" M
IN
5'
32" MIN.
4"
3' -4
" M
IN
1'-6"
3' MIN.
1'-6"
4' MIN.
" I
F
FL
O O
R M
TD
" I
F W
AL
L
M
TD
32" MIN. 32" MIN.
3' -4
" M
IN
4' 6"2'-6"
4' 2'-6"
2' -6
X
X
4'
2' -6
4'
2'-6"
4'
2' -6
X
X
36" MIN.
" M
AX
PE
RF
ER
ED
" M
IN
36" MIN.
3" MIN. 6"
" M
IN
1.5" 0 RAIL
(SS OR
CHROME)3'-6" MIN.12"
3' MAX.
12"18"
MIN.
18"
MIN.2'
-1 0"
3'
-2
2'
-3
12" 12"
CLEAR FLOOR SPACE AT WATER
CLOSETS
ALTERNATE LOCATIONS OF
PANEL WITH SIDE OPENING
DOOR
ALTERNATE LOCATIONS OF
PANEL WITH CENTER OPENING
DOOR
CLEAR DOORWAY WIDTH AND
DEPTH
MAXIMUM DOORWAY
DEPTH
CAR CONTROL
HEIGHT
FOLDING
DOOR
(e) SLIDE SIDE FRONT
APPROACHE-SLIDING DOORS
AND FOLDING DOORS
(d) FRONT APPROACHES-SLIDING
DOORS AND FOLDING DOORS
ELEVATION E (e) LATCH SIDE FRONT
APPROACHE-SLIDING DOORS
AND FOLDING DOORS
WITH SEAT AT HEAD OF
TUB
SHOWER SIZE AND
CLEARANCES
30" BY 60"
STALL
FIG. 35 SHOWER SIZE AND
CLEARANCES
(a) WITH
SEAT IN TUB
WITH SEAT AT
HEAD OF TUBCLEAR FLOOR SPACE AT BATHTUBS
SE
AT
FO
O
T
H
EA
D
FO
O
T
SE
AT
BACKBACK
BACK (LONG) (b) 36" BY
60" STALL
NOTE: Y=54" IF DOOR HAS
CLOSER
NOTE: SHOWERHEAD AND CONTROL AREA MAY BE ON
BACK (LONG) WASS (AS SHOWN) OR ON EITHER SIDE WALL
CLEAR
FLOOR
SPACE
CLEAR
FLOOR
SPACE
EDGE PROTECTION 12"
EXTENSION BEYOND RAIL
EDGE PROTECTION 2" MINIMUM
NOTE: X=12" IF DOOR HAS
BOTH CLOSER AND LATCH
NOTE: Y=48" MIN. IF DOOR HAS
BOTH LATCH AND CLOSER
CLEAR FLOOR SPACE IN ALCOVES
MANEUVERING CLEARANCES AT DOORS
(b)
FORWARD
APPROACH
(b) MAXIMUM FORWARD
REACH OVER AN
OBSTRUCTION
WALKING
PARALLEL
TO A WALL
OCTAGON SYMBOL
SHALL BE RAISED
BUT `X' IS NOT
DOOR OPEN
EMERGENCY
ALARM
MAIN ENTRY
FLOOR
DOOR
CLOSED
3/4" BUTTON
DIAMETER
DIRECTION OF
APPROACH
PULL
SIDE
CLEAR
FLOOR
SPACE CLEAR
FLOOR
SPACE
FO
O
T
BACK
(a) PANEL DETAIL
5/8" NUMERAL
HEIGHT
3"
3.25"18 " M
IN
℄ RAMP
2"
FIG. 32
FIG. 35
(b)
LA
V.
SI
DE
HEAD
(b)
BACKFOOT
HANDRAIL
FIG. 39
(D)
HANDRAIL
(C)
HANDRAIL
(B)
HANDRAIL
T-SHAPED SPACE FOR 180 TURNS
FIG. 28
LAV.
LAV.
(d)(c) FIG. 24
(e)
(b)
ELEVATION D
END OF RAMP
1.25"-1.5"
FIG. 53 FOOD
SERVICE LINES
PULL SIDE
PUSH SIDE
FIG. 54
TABLEWARE AREAS
FORWARD REACH
LAV LAV.
H
EA
D
SE
AT
FIG. 33 (b)
CANE RANGE
PLAN
(A)
HANDRAIL
(c) (d)
(a-1)
SHOWER CONTROLS SHOWER HEAD DRAIN
Y = 60" IF X = 36
Y = 54" IF X = 42
22" MIN.
Y
" M
IN
IF
D
O O
R H
AS
B
O
TH
A
LA
TC
H
AN
D
A C
LO
SE
R
X
SIGN BACKGROUND COLOR:
PMS262C. REFER TO SPEC FOR
ADDITIONAL INFORMATION.
LETTERS AND NUMBERS
SHALL BE UPPER CASE,
SANS SERIF TYPE
COLOR: WHITE
CORRESPONDING GRADE 2
BRAILLE REFER TO TACTILE
NOTES (THIS DETAIL) FOR
ADDITIONAL INFORMATION.
LETTERS AND
NUMBERS SHALL
BE AT LEAST 5/8"
HIGH, BUT NO
HIGHER THAN 2"
LETTERING
RAISED 1/32"
EXIT
TACTILE SIGNAGE SHALL BE ALLOWED ON THE
PUSH SIDE OF A DOOR WHEN THE FOLLOWING
CONDITIONS EXIST: DOOR HAS A CLOSER,
DOOR DOES NOT HAVE A HOLD OPEN DEVICE
THAT PREVENTS IT FROM CLOSING.
9"
MIN.
WALL MOUNTED TACTILE
SIGNAGE TO BE LOCATED ON
LATCH SIDE OF DOOR CLEAR
OF DOOR SWING. MOUNT @
48 MIN. (TO BOTTOM) 60" MAX.
(TO TOP) OF SIGN TO FLOOR.
EXIT
" M
AX
T
O T
O P
" M
IN
. 4
4" M
AX
2' -6
4'-0"
Z
X
4'-0"
Z
LAV.
X
Y
4'-0"
4' M
AX
FO
RW
AR
D
RE
AC
H
M
IN
2'
-6
2'-6"
12"
M
AX
OBJECTS
PROTRUDING OFF
WALL/CEILING
3'-0" 3'
-0
9" 4"
1'-0"
" M
IN
2"
G-002
ACCESSIBILITY REQUIREMENTS
NOTES AND DETAILS
MV
BK
BK
This drawing is an instrument of service, remains the property of Detroit Architectural Group, Inc. Any changes, publication, or unauthorized use is prohibited unless expressly approved.
24-131.2
SHEET NO:
JOB NO:
SHEET NAME:
IN CHARGE:
CHECKED BY:
DRAWN BY:
SEAL:
REV DATE ISSUED
ENGINEERING, INC.
25041
JRED PROJECT NUMBER:
Consulting Engineers 14115 Farmington Rd., Ste. 100 Livonia, MI 48154 Tel: (734) 855-4904 email: esteban@jredengineering.com
CITY OF
GARDEN CITY -
RADCLIFF
CENTER
Proposed Toilet Room Upgrades
- Group #2 -
1751 RADCLIFF ST.
GARDEN CITY, MI 48135
BIDS & PERMITS03-26-25
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
C RAIL MOUNT
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
AutoCAD SHX Text
OCCUPANCY CALCULATIONS (TABLE 1004.1.2)
FUNCTION OF SPACE AREA (sf) FLOOR AREA PER OCCUPANT (sf) OCC LOAD
SHOPS / VOCATIONAL
TRAINING AREAS
TOTAL 1,750
ED
U
CA
TI
O N
AL
~87,500 1,75050 net
PLUMBING FIXTURES CALCULATIONS (TABLE 403.1) - EXISTING
DF SS
1 per 100
1 per 50 1 per 50
35 35
17 req'd
(X) prov'd
1 req'd
(X) prov'd
WC -
MALE
WC -
FEMALE
LAV -
MALE
LAV -
FEMALE
35 req'd
(22) prov'd (17) prov'd
35 req'd
(8) prov'd (9) prov'd
LOCKER ROOMS
LOCKER ROOMS
PRIVATE / UNISEX
(3) prov'd (3) prov'd
PRIVATE / UNISEX
17 req'd
(X) prov'd
1 req'd
(X) prov'dTOTAL 35 req'd
(20) prov'd 35 req'd
(42) prov'd
This drawing is an instrument of service, remains the property of Detroit Architectural Group, Inc. Any changes, publication, or unauthorized use is prohibited unless expressly approved.
24-131.2
SHEET NO:
JOB NO:
SHEET NAME:
IN CHARGE:
CHECKED BY:
DRAWN BY:
SEAL:
REV DATE ISSUED
ENGINEERING, INC.
25041
JRED PROJECT NUMBER:
Consulting Engineers 14115 Farmington Rd., Ste. 100 Livonia, MI 48154 Tel: (734) 855-4904 email: esteban@jredengineering.com
CITY OF
GARDEN CITY -
RADCLIFF
CENTER
Proposed Toilet Room Upgrades
- Group #2 -
1751 RADCLIFF ST.
GARDEN CITY, MI 48135
G-003
PLUMBING FIXTURE CALCULATIONS
AND LIFE SAFETY PLAN
MV
BK
BK
NORTH
SCALE:
LIFE SAFETY PLAN
N.T.S.
TOILET GROUP #1:
EXISTING
WC - 6 male / 5 female LAV - 3 male / 3 female
TOILET GROUP #2:
EXISTING
WC - 4 male / 3 female LAV - 1 male / 2 female
PROPOSED
WC - 3 male / 4 female LAV - 2 male / 4 female
TOILET GROUP #3:
EXISTING
WC - 5 male / 3 female LAV - 2 male / 2 female
TOILET GROUP #4:
EXISTING
WC - 7 male / 6 female LAV - 2 male / 2 female
BIDS & PERMITS03-26-25
1 1
4A
4A
5 5
MEN'S TLT
RC23
WOMEN'S TLT
RC25
STOR./J.C.
RC24
2B
4A
4A
2A
2A
5' -6
6'-0"
'-3
4A
4A
4A
4A
4A
4A
STOR./J.C.
RC24
1' -6
M
AX
WC-2
WC-2
UR-1
UR-1
LAV-1
EWC
MEN'S TLT
RC23
WOMEN'S TLT
RC25
11'-0"±
5'-0"
1' -3
M
IN
6'-0"
LAV-1
LAV-1
5' -6
5'-0"
'-3
5' -5
1' -3
M
IN
EQ 1'
-8
1'-10"± 1'-6"
MIN
1' -3
M
IN
1'
-3
M
IN
2'-0"± 1'-6"
MIN
1'-10"
WC-1
WC-1
2' -1
1" 2'
-1 1"
2' -1
1"
5' -7
1 2"
5' -7
1' -4
" M
IN
1' -6
" M
AX
5'-0"
2' -5
1'
-3 " M
IN
2'
-0
2' -0
1' -6
1'
-3 " M
IN
2'
-5
LAV-3
2 3
A-401
3A
A-401
8A A-401
6A
8 A-401
A-401
7A
5A
A-401
EQ 1'
-8
3A
EXISTING INTERIOR DOOR AND FRAME ASSEMBLY TO BE REMOVED.
EXISTING MILLWORK/CASEWORK ASSEMBLY TO BE REMOVED.
EXISTING FLOOR FINISH THIS AREA TO BE REMOVED.
EXISTING PLUMBING FIXTURES AND ALL ASSOCIATED PLUMBING
TO BE REMOVED.
EXISTING TOILET PARTITION AND ASSOCIATED HARDWARE
TO BE REMOVED.
EXISTING SPECIALTY ACCESSORIES (GRAB BARS, PAPER TOWEL
HOLDER, SOAP DISPENSER, ETC.) TO BE SALVAGED FOR RE-USE,
COORDINATE WITH OWNER AS REQUIRED.
DEMOLITION KEYED NOTES
PORTION OF EXISTING CMU WALL TO BE REMOVED FOR WALL OR
DOOR OPENING.
EXISTING BABY CHANGING STATION TO BE SALVAGED FOR
RE-USE.
PORTION OF EXISTING INTERIOR WALL PARTITION TO BE
REMOVED FOR INSTALLATION OF NEW DOOR AND FRAME.
2B
EXISTING NON-COMPLIANT DRINKING FOUNTAIN TO BE
REMOVED AND REPLACED WITH COMPLIANT MODEL.
EXISTING PLUMBING FIXTURES TO BE REMOVED. RETROFIT
ASSOCIATED PLUMBING AS REQUIRED FOR NEW PLUMBING
FIXTURES.
4A
EXISTING PARTIAL HEIGHT CMU WALL TO BE REMOVED COMPLETE.2A
DEMOLITION PLAN LEGEND
DEMO WALL
NOTE:
ALL DIMENSIONS AT SELECTIVE EXISTING CONDITIONS AND NEW
CONSTRUCTION ARE APPROXIMATE.
DEMO OTHER
EXISTING TERRAZZO FLOOR TO BE SAWCUT AND REMOVED AS
NEEDED FOR REMOVAL OF EXISTING FIXTURES AND WALLS.
FLOOR PLAN LEGEND
EXIST. 8" CMU WALL TO REMAIN
NOTE:
ALL DIMENSION AT SELECTIVE EXISTING CONDITION AND NEW
CONSTRUCTION ARE APPROXIMATE.
EXIST. GYP. BD. ON METAL STUD WALL TO REMAIN
NEW INTERIOR WALL PARTITION, SEE WALL TYPE LEGEND,
THIS SHEET.
1. DEMOLITION CONTRACTOR TO VERIFY CONDITION OF AREA TO BE
IMPROVED PRIOR TO STARTING WORK.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL, DEMOLITION,
CUTTING AND PATCHING OF ALL EXISTING COMPONENTS AND
SYSTEMS WHATSOEVER TO PREPARE AREA FOR ALL INTERIOR
IMPROVEMENTS.
3. IF ASBESTOS OR OTHER HAZARDOUS MATERIALS ARE ENCOUNTERED,
WORK IS TO STOP AND OWNER REPRESENTATIVE IS TO BE NOTIFIED.
OWNER IS RESPONSIBLE FOR REMOVAL AND DISPOSAL OF ALL
HAZARDOUS MATERIAL.
4. ELECTRICAL DEMOLITION
A. ALL EXISTING DEAD WIRING, WIREWAYS, AND CONDUIT IN
RENOVATED AREAS SHALL BE REMOVED IN ITS ENTIRETY WHERE
ACCESSIBLE. WHERE NOT ACCESSIBLE, WIRING ONLY SHALL BE
REMOVED AND CONDUIT SHALL REMAIN CUT OFF AT WALL OR
FLUSH WITH FLOOR.
B. REWORK ALL EXISTING WIRING, CONDUIT, ETC. REMAINING IN
USE AND FALLING WITHIN EXISTING WALLS WHICH ARE BEING
REMOVED TO NEAREST EXISTING WALLS REMAINING.
C. DISCONNECT AND REMOVE ANY ELECTRICAL EQUIPMENT IN
CEILING SPACE OR WALLS THAT CAUSES INTERFERENCES DURING
RENOVATION WORK. ALL EQUIPMENT SHALL BE REPLACED AND
RECONNECTED UPON COMPLETION OF RENOVATION WORK.
D. ELECTRICAL EQUIPMENT BEING REMOVED AND NOT BEING
REUSED SHALL BE REMOVED FROM SITE AND DISPOSED OF BY
THIS TRADE.
E. EXISTING CONDUIT IN SPACE MAY BE REUSED. BRANCH HOME
RUN CONDUIT MAY BE REUSED.
F. EXISTING ABANDONED CONDUIT AND WIRING IN RENOVATION
AREA SHALL BE REMOVED.
5. CONCRETE TO BE 4,000 PSI MIN. STRENGTH AT 28 DAYS.
DEMOLITION GENERAL NOTES
FLOOR PLAN KEYED NOTES
3 NEW MIRROR AT SINK
4 NEW TOILET PARTITIONS AS SHOWN, SEE SHEET A-601
NEW LAVATORY SINK
RELOCATED BABY CHANGING STATION5
6 INFILL EXISTING DOOR OPENING AS SHOWN
CMU WALL INFILL
INFILL WITH 8" CMU TO MATCH
EXISTING ADJACENT (V.I.F.)
8" N
O M
NEW INTERIOR WALL
5/8" G.W.B. EACH SIDE ON 3 5/8" METAL
STUDS TO EXTEND TO UNDERSIDE OF DECK
ABOVE, W/ BATT INSULATION
5" N
O M
NEW INTERIOR WALL
5/8" G.W.B. ROOM SIDE ONLY OF 6" METAL
STUDS TO EXTEND TO UNDERSIDE OF
EXISTING CEILING
2"
N O
M
NEW 36" DOOR, SEE DOOR SCHEDULE, SHEET A-6011
WALL TYPE LEGEND
7 NEW GRAB BARS AS REQUIRED
8 NEW COMPLIANT ELEC WATER COOLER
NOTE:
SEE PLUMBING SHEETS FOR PLUMBING FIXTURE SCHEDULE.
9 CONCRETE INFILL WHERE TERRAZZO IS REMOVED (HARD
TROWEL FINISH)
10 EXISTING HOLES IN CMU WALL ARE TO BE FILLED AND
PATCHED PRIOR TO FINISH MATERIAL APPLICATION
3A NEW FULL LENGHT MIRROR
This drawing is an instrument of service, remains the property of Detroit Architectural Group, Inc. Any changes, publication, or unauthorized use is prohibited unless expressly approved.
24-131.2
SHEET NO:
JOB NO:
SHEET NAME:
IN CHARGE:
CHECKED BY:
DRAWN BY:
SEAL:
REV DATE ISSUED
ENGINEERING, INC.
25041
JRED PROJECT NUMBER:
Consulting Engineers 14115 Farmington Rd., Ste. 100 Livonia, MI 48154 Tel: (734) 855-4904 email: esteban@jredengineering.com
CITY OF
GARDEN CITY -
RADCLIFF
CENTER
Proposed Toilet Room Upgrades
- Group #2 -
1751 RADCLIFF ST.
GARDEN CITY, MI 48135
NORTH
SCALE: 2PROPOSED FLOOR PLAN
1/2" = 1'-0"
NORTH
SCALE: 1DEMOLITION PLAN
1/2" = 1'-0"
A-101
DEMOLITION AND PROPOSED FLOOR
PLANS
MV
BK
BK
NORTH
SCALE:
KEY PLAN
N.T.S.
WORK AREA
BIDS & PERMITS03-26-25
AutoCAD SHX Text K-4915
AutoCAD SHX Text
BARDON
AutoCAD SHX Text
C_URINALS
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text K-4915
AutoCAD SHX Text
BARDON
AutoCAD SHX Text
C_URINALS
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text K-4915
AutoCAD SHX Text
BARDON
AutoCAD SHX Text
C_URINALS
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text K-4915
AutoCAD SHX Text
BARDON
AutoCAD SHX Text
C_URINALS
VITREOUS CHINA
MEN'S TLT
RC23
WOMEN'S TLT
RC25
STOR./J.C.
RC24
~158 SF
~235 SF
CT
-1
,2
TS-XTS-X
CT-1,2,3
CT-1,2
CT
-1
,2
CT
-1
,2 ,3
CT
-1
,2
CT-1,2
CT-1,2,3
CT-1,2
CT
-1
,2 ,3
CT
-1
,2 ,3
CT-1
CT-1
CT
-1
,2 ,3
CT
-1
,2 ,3
CT
-1
,2 ,3
MEN'S TLT
RC23
WOMEN'S TLT
RC25
STOR./J.C.
RC24
9'-0"±9'-0"±
X'-X"± (V.I.F.)
X'-X"± (V.I.F.)
EXIST. GB SOFFIT
EXIST. GB
CEILING
NEW GB CEILING TO
MATCH EXIST SOFFIT
X'-X" - 6"
NEW GB
BULKHEAD
'A'
'A'
'A''A'
'A'
ROOM FINISH LEGEND
EXISTING TERRAZZO FLOORING TO BE
PREPARED AS REQ'D FOR NEW EPOXY
COATING
TS-X
FLOOR TRANSITION TO BE
LOCATED BENEATH CLOSED DOOR,
SEE DETAILS SHEET A-701
1. ALL WALL PAINT TO BE PT-1 EXCEPT WHERE NOTED ON FINISH PLAN.
2. COORDINATE FLOORING MATERIAL WITH OWNER (TYP).
3. FLOOR TRANSITIONS WHICH OCCUR AT DOORS SHALL BE CENTERED
BENEATH THE DOOR WHILE IN THE CLOSED POSITION.
4. COORDINATE LOCATIONS OF FLOORING TRANSITIONS WITH FINISH
PLANS AND SCHEDULE.
FINISH PLAN NOTES
DENOTES WHOLE WALL SIDE
*REFER TO ROOM FINISH SCHEDULE
& NOTES FOR FURTHER INFORMATION
CT- #
EXISTING VCT FLOORING TO BE
REMOVED AND PREPARED AS REQ'D
FOR NEW EPOXY COATING
RCP KEYED NOTES
REFLECTED CEILING LEGEND
AIR EXHAUST GRILLE
GB-1
SUSPENDED GYPSUM BOARD CEILING ASSEMBLY
NOTE:
COORDINATE LOCATION OF LIGHTING, HVAC AND SPRINKLER HEADS WITH
SUSPENDED CEILING GRID (TYP).
2x4 LITHONIA LIGHTING CPANL LED FLAT PANEL -
FULLY SWITCHABLE MODEL # CPANL 2X4 ALO1 SWW7
DIRECT SURFACE MOUNT
NEW 2X4 LED LIGHT FIXTURE TO REPLACE EXISTING.
PATCH AND REPAIR EXISTING CEILING AS NEEDED TO
ACCOMMODATE NEW WORK.
NEW DIFFUSERS AT EXISTING MECHANICAL EQUIPMENT -
SEE SHEET MP-100 FOR MORE INFORMATIONS.
A.F.F. CEILING HEIGHT
9'-0"
EXISTING TO REMAIN:
EXISTING CONSTRUCTION TO REMAIN SHOWN
LIGHTER THAN NEW WORK (DARKER). REQUEST
CLARIFICATION FROM ARCHITECT WHERE
NECESSARY.
(E)
EXISTING CEILING TO BE PATCHED AND REPAIRED AS NEEDED.
NEW PAINTED FINISH - SEE FINISH SCHEDULE SHEET A-601.
WALL-MOUNTED FIRE ALARM/STROBE
'A'
This drawing is an instrument of service, remains the property of Detroit Architectural Group, Inc. Any changes, publication, or unauthorized use is prohibited unless expressly approved.
24-131.2
SHEET NO:
JOB NO:
SHEET NAME:
IN CHARGE:
CHECKED BY:
DRAWN BY:
SEAL:
REV DATE ISSUED
ENGINEERING, INC.
25041
JRED PROJECT NUMBER:
Consulting Engineers 14115 Farmington Rd., Ste. 100 Livonia, MI 48154 Tel: (734) 855-4904 email: esteban@jredengineering.com
CITY OF
GARDEN CITY -
RADCLIFF
CENTER
Proposed Toilet Room Upgrades
- Group #2 -
1751 RADCLIFF ST.
GARDEN CITY, MI 48135
A-102
REFLECTED CEILING AND ROOM FINISH
PLANS
MV
BK
BK
NORTH
SCALE: 4ROOM FINISH PLAN - GROUP #2
1/4" = 1'-0"
NORTH
SCALE: 3REFLECTED CEILING PLAN - GROUP #2
1/4" = 1'-0"
FINISH SUMMARY
MEN'S (RC23) WOMEN'S (RC25)
FLOOR AREA (SF) 157 235
TOTAL WALL AREA (SF) 549 792
BASE LENGTH (LF) 61 88
NORTH
SCALE:
KEY PLAN
N.T.S.
WORK AREA
BIDS & PERMITS03-26-25
AutoCAD SHX Text K-4915
AutoCAD SHX Text
BARDON
AutoCAD SHX Text
C_URINALS
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text K-4915
AutoCAD SHX Text
BARDON
AutoCAD SHX Text
C_URINALS
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text F
AutoCAD SHX Text F
F
1'-3" 1'-3"1'-3" 1'-3" EQ.
1'-8"±
EQ.
1'-8"±
5'-5"±
1' -0
M
IN WC-2
UR-1
UR-1
LAV-1
TOILET PARTITION BEYOND
1'-6"
MAX
1'-10"
WALL-MOUNTED
1-STATION TROUGH
SINK UNIT
24"Wx36"H MIRROR
LAV-1
SEE MECH.
DRAWINGS
NEW URINAL DIVIDER PARTITION
RELOCATED BABY
CHANGING STATION
WALL-MOUNTED
1-STATION TROUGH
SINK UNIT
24"Wx36"H
MIRROR
SCHLUTER TRIM
(TYP)
EXISTING MECHANICAL SCREEN TO BE
PAINTED GREEN TO MATCH THE TILES
NEW ELEC
WATER
COOLER
WOOD DOOR W/ LOUVERS,
SEE DOOR SCHEDULE
WOOD DOOR
W/ LOUVERS, SEE
DOOR SCHEDULE
EXIST.
CORRIDOR
EXIST. DOOR TO J.C. TO REMAIN
5'-5"±
2' -1
0" M
AX
2' -9
"4' -1
2' -1
0" M
AX
WOOD DOOR W/ LOUVERS,
SEE DOOR SCHEDULE
TOWEL
DISPENSER
& WASTE
RECEPTACLE
GRAB
BARS
(TYP)
TOILET PARTITION
TOILET
PAPER
DISPENSER
SCHLUTER TRIM (TYP)
EXISTING EMERGENCY
STROBE LIGHT
TOWEL DISPENSER &
WASTE RECEPTACLE
SCALE: 5AINTERIOR ELEVATION - MEN'S TOILET ROOM RC23
3/8" = 1'-0"
SCALE: 3AINTERIOR ELEVATION - MEN'S TOILET ROOM RC23
3/8" = 1'-0" 3
SCALE: 1INTERIOR ELEVATION - EXISTING CORRIDOR
3/8" = 1'-0"
A-401
INTERIOR ELEVATIONS
MV
BK
BK
This drawing is an instrument of service, remains the property of Detroit Architectural Group, Inc. Any changes, publication, or unauthorized use is prohibited unless expressly approved.
24-131.2
SHEET NO:
JOB NO:
SHEET NAME:
IN CHARGE:
CHECKED BY:
DRAWN BY:
SEAL:
REV DATE ISSUED
ENGINEERING, INC.
25041
JRED PROJECT NUMBER:
Consulting Engineers 14115 Farmington Rd., Ste. 100 Livonia, MI 48154 Tel: (734) 855-4904 email: esteban@jredengineering.com
CITY OF
GARDEN CITY -
RADCLIFF
CENTER
Proposed Toilet Room Upgrades
- Group #2 -
1751 RADCLIFF ST.
GARDEN CITY, MI 48135
SCALE: 2INTERIOR ELEVATION - MEN'S TOILET ROOM RC23
3/8" = 1'-0"
SCALE: 4INTERIOR ELEVATION - MEN'S TOILET ROOM RC23
3/8" = 1'-0"
BIDS & PERMITS03-26-25
ALTERNATE 01:
AS AN ALTERNATE PLEASE SUBMIT
COST REDUCTION FOR OMITTING
THE CERAMIC/PORCELAIN TILE AND
PAINTING THE EXISTING CMU WALLS
AND NEW CONSTRUCTION PER THE
FINISH SCHEDULE (2-3 COLORS)
TILE PATTERN:
FINAL PATTERN IS TBD AND WILL REFLECT THE
4"x12" TILE AS SPECIFIED. INTERIOR ELEVATIONS
REPRESENT AN APPROXIMATE PATTERN AND
APPROACH TO % OF EACH COLOR.
AutoCAD SHX Text
K-4960-ER
AutoCAD SHX Text
BARDON
AutoCAD SHX Text
C_URINALS
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text
K-4960-ER
AutoCAD SHX Text
BARDON
AutoCAD SHX Text
C_URINALS
VITREOUS CHINA
2'-0" 2'-0"2'-5"± 1'-3"
MIN
WALL-MOUNTED 3-STATION
TROUGH SINK UNIT
EXIST. SOFFIT (V.I.F.)
LAV-2
EXIST. SOFFIT (V.I.F.)
OPEN TO
BEYOND
18"Wx36"H MIRROR
(TYP OF 3)
GRAB
BARS
(TYP) RELOCATED
BABY
CHANGING
STATION
OPEN TO
BEYOND
RELOCATED
SANITARY NAPKIN
DISPENSER
TOILET PARTITION (TYP)
SCHLUTER TRIM
(TYP)
LAV-1
WC-2
1'-6"± 1'-3"
MIN5'-7"±
2'-11"± 2'-11"± 2'-11"±
TOILET PARTITION (TYP)
WC-1 WC-1 WC-1
24"Wx36"H MIRROR
OPEN TO
BEYOND
WALL-MOUNTED
1-STATION TROUGH
SINK UNIT
SEE MECH.
DRAWINGS
EXISTING MECHANICAL SCREEN TO BE
PAINTED GREEN TO MATCH THE TILES
INFILL WALL
OPENING
WOOD DOOR W/ LOUVERS,
SEE DOOR SCHEDULE
EXIST. SOFFIT (V.I.F.)
24"Wx60"H MIRROR
SCHLUTER TRIM
(TYP)
EXIST. EMERGENCY
STROBE LIGHT
A-402
INTERIOR ELEVATIONS
MV
BK
BK
This drawing is an instrument of service, remains the property of Detroit Architectural Group, Inc. Any changes, publication, or unauthorized use is prohibited unless expressly approved.
24-131.2
SHEET NO:
JOB NO:
SHEET NAME:
IN CHARGE:
CHECKED BY:
DRAWN BY:
SEAL:
REV DATE ISSUED
ENGINEERING, INC.
25041
JRED PROJECT NUMBER:
Consulting Engineers 14115 Farmington Rd., Ste. 100 Livonia, MI 48154 Tel: (734) 855-4904 email: esteban@jredengineering.com
CITY OF
GARDEN CITY -
RADCLIFF
CENTER
Proposed Toilet Room Upgrades
- Group #2 -
1751 RADCLIFF ST.
GARDEN CITY, MI 48135
SCALE: 8AINTERIOR ELEVATION - WOMEN'S TOILET ROOM RC25
3/8" = 1'-0"
SCALE: 6AINTERIOR ELEVATION - WOMEN'S TOILET ROOM RC25
3/8" = 1'-0" 6
SCALE: 7AINTERIOR ELEVATION - WOMEN'S TOILET ROOM RC25
3/8" = 1'-0" 7
SCALE: 9INTERIOR ELEVATION - WOMEN'S TOILET ROOM RC25
3/8" = 1'-0"
BIDS & PERMITS03-26-25
ALTERNATE 01:
AS AN ALTERNATE PLEASE SUBMIT
COST REDUCTION FOR OMITTING
THE CERAMIC/PORCELAIN TILE AND
PAINTING THE EXISTING CMU WALLS
AND NEW CONSTRUCTION PER THE
FINISH SCHEDULE (2-3 COLORS)
TILE PATTERN:
FINAL PATTERN IS TBD AND WILL REFLECT THE
4"x12" TILE AS SPECIFIED. INTERIOR ELEVATIONS
REPRESENT AN APPROXIMATE PATTERN AND
APPROACH TO % OF EACH COLOR.
NOTES:
OWNER TO PROVIDE SIGNAGE TO
MATCH EXISTING OR AS REQUIRED.
SCALE:
DOOR TYPES
1/4" = 1'-0"
7' -0
3'-0"
M
IN
1' -0
M
IN
A
LOUVERS KICK PLATE
This drawing is an instrument of service, remains the property of Detroit Architectural Group, Inc. Any changes, publication, or unauthorized use is prohibited unless expressly approved.
24-131.2
SHEET NO:
JOB NO:
SHEET NAME:
IN CHARGE:
CHECKED BY:
DRAWN BY:
SEAL:
REV DATE ISSUED
ENGINEERING, INC.
25041
JRED PROJECT NUMBER:
Consulting Engineers 14115 Farmington Rd., Ste. 100 Livonia, MI 48154 Tel: (734) 855-4904 email: esteban@jredengineering.com
CITY OF
GARDEN CITY -
RADCLIFF
CENTER
Proposed Toilet Room Upgrades
- Group #2 -
1751 RADCLIFF ST.
GARDEN CITY, MI 48135
A-601
DOOR AND ROOM FINISH SCHEDULES
MV
BK
BK
RC25 7 8A F-1 1
A 7 8F-1 1
RC23
3'-0" x 7'-0" x 1 3/4"
3'-0" x 7'-0" x 1 3/4"
DOOR SCHEDULE
NO. SIZE DOOR NOTES
WxHxTHK
AN
O
D.
A
LU
M
FR
AM
E
G
LA
SS
W O
O D
TY
PE
HO
LL
O W
M
ET
AL
M
ET
AL
"K
N O
CK
-D
O W
N
TY
PE
1 2 3 4 5 6 7 8 9 10 11 13 14 15 16 18
2" P
R
HV
Y.
W
EI
GH
T
BU
TT
S
KE
YE
D
LO
CK
S
ET
ST
O
RE
RO
O M
LO
CK
ES
T
PA
SS
AG
E
LA
TC
H
SE
T
PR
IV
AC
Y
LA
TC
HS
ET
DE
AD
B O
LT
CL
O
SE
R
PU
SH
P U
LL
EN
TR
Y
PU
SH
PU
LL
W
AL
L
ST
O P
O
VE
RH
EA
D
ST
O P
AL
U
M
IN
U M
TH
RE
SH
O
LD
W
EA
TH
ER
ST
RI
PP
IN
G
KI
CK
PL
AT
E
AN
O
D.
A
LU
M
DO
O
R
VI
EW
ER
HO
LL
O W
M
ET
AL REFER TO DOOR NOTES FOR
CONDITIONS APPLYING TO
SPECIFIC DOORS OR SETS OF
DOORS - DOOR NOTES NOT
REFERENCED IN THIS COLUMN
ARE TO BE CONSIDERED GENERAL
DOOR NOTES.
PA
N
IC
HA
RD
W
AR
E
EX
IT
D
EV
IC
E
SI
DE
LI
TE
FRAME HARDWARE
O
FF
SE
T
PI
VO
T
HI
N
GE
S
INTERIOR MATERIALS LEGEND
CERAMIC WALL TILE
CT-1 (FIELD)
WALL BASE
MISCELLANEOUS
PAINT / WALL COVERINGS
PT-1
PT-2
MANUFACTURER: AMERICA OLEAN
STYLE: COLOR STORY
SIZE: 4" x 12"
COLOR: 0025 ICE WHITE
LOCATION: WALLS
PATTERN: SEE INTERIOR ELEVATIONS
MANUFACTURER: JOHNSONITE
TYPE: T.B.D.
COLOR: T.B.D.
LOCATION: NEW WALLS ON CLASS ROOM SIDE
OF WOMEN'S TOILET ROOM ADDITION
MANUFACTURER: SHERWIN WILLIAMS
COLOR: T.B.D.
FINISH: SEMI-GLOSS
LOCATION: WALLS (FIELD)
MANUFACTURER: SHERWIN WILLIAMS
COLOR: T.B.D.
FINISH: SEMI-GLOSS
LOCATION: WALLS (ACCENT)
RC25
RC23 EP-1 - -MEN'S TOILET
WOMEN'S TOILET EP-1 -
GB-1/PT-3
GYP. BD. CEILING
GB-1
DESCRIPTION: 5/8" GYPSUM BOARD, ON USG
DRYWALL SUSPENSION SYSTEM (DGW) OR SIMILAR
PT-3
MANUFACTURER: SHERWIN WILLIAMS
COLOR: SW7007 PURE WHITE
FINISH: EGGSHELL
LOCATION: GYP. BD. CEILING/BULKHEAD/SOFFIT
WOOD DOORS
MANUFACTURER: MARSHFIELD (TBD)
VENEER: TO MATCH EXISTING
COLOR: (TBD) TO MATCH EXISTING
LOCATION: ALL DOORS
(UNLESS NOTED OTHERWISE)
HEADRAIL BRACED
MANUFACTURER: GENERAL PARTITIONS
SERIES: 40 SERIES
(FLOOR SUPPORTED - HEADRAIL)
COLOR: 274 HUNTER (T.B.C.)
FINISH: HIGH DENSITY POLYMER
TOILET PARTITIONS
VB-1
TRASH RECEPTACLE
BOBRICK B-9279
SURFACE-MOUNTED WASTE RECEPTACLE FINO COLLECTION SATIN
FINISH 6 GAL
STALL HOOKS - ONE PER STALL
BOBRICK - MODEL B-670
TOILET PAPER DISPENSERS
BOBRICK B-2888
SURFACE-MOUNTED MUILTI-ROLL TOILET TISSUE DISPENSER
HANDS FREE WALL-MOUNTED TOWEL DISPENSERS (HARD WIRED)
ENMOTION # 59466 WITH AC ADAPTER STAINLESS STEEL FINISH
FEMININE PRODUCTS DISPOSAL
AMERICAN SPECIALTIES 0473-1A (WITH LOCK)
BABY CHANGING STATION
BRADLEY STAINLESS STEEL BABY CHANGING STATION MODEL 962
MIRROR
BRADLEY CORP 780 SERIES ANGLE FRAME MIRROR
18"x36", 24"x36", OR 24"x60"
GRAB BARS
AMERICAN SPECIALTIES 3800 SERIES STAINLESS STEEL
18", 36", OR 42"
TOILET ROOM ACCESSORIES
FINISH GENERAL NOTES
1. REFER TO ARCHITECTURAL FINISH SCHEDULE FOR LOCATION OF ACCENT PAINT, CORNER GUARDS, CARPET TILE, WALL TILE AND FLOOR TILE MATERIALS AND LOCATIONS.
2. SUBMIT PRODUCT DATA AND SAMPLES FOR EACH TYPE OF PRODUCT INDICATED. ALL FLOORING
MATERIAL MUST BE FROM THE SAME DYE LOT OR MANUFACTURER'S PRODUCT RUN. CARTON
PRODUCTS MUST BE IN SAME SEQUENCE.
3. ALL FLOORING INSTALLATION AND FLOOR PREPARATION SHALL BE PERFORMED BY AN EXPERIENCED
CERTIFIED CARPET INSTALLER.
4. CONTRACTOR TO CONDITION ALL FLOORING MATERIAL ON SITE FOR AT LEAST 24 HOURS PRIOR TO
INSTALLATION AND MAINTAIN AIR AND FLOOR TEMPERATURE AT A MINIMUM OF 65 DEGREES
FAHRENHEIT, 48-72 HOURS PRIOR TO, DURING AND AFTER INSTALLATION.
5. RELATIVE HUMIDITY IN SUBSTRATE SHALL BE DETERMINED BY THE ASTM-F-2170-09 'RELATIVE
HUMIDITY IN SITU PROBE TEST' AND SHALL NOT EXCEED 85%.
6. CONCRETE SUBFLOOR SHALL BE SOUND AND FREE OF OIL, GREASE, PAINT AND ANY OTHER FOREIGN
SUBSTRATE THAT MAY INHIBIT ADHESION. SURFACES MUST BE SMOOTH AND LEVEL BEFORE
INSTALLATION.
7. CONCRETE SURFACES MUST BE SMOOTH AND LEVEL BEFORE INSTALLATION. HIGH POINTS ARE TO BE
GRINDED, LOW POINTS ARE TO BE SKIM COATED.
8. TROWELABLE LEVELING AND PATCHING COMPOUNDS TO BE A CARPET MANUFACTURER APPROVED
LATEX-FORTIFIED PORTLAND CEMENT BASED PATCH, OR LEVELING COMPOUNDS. FLOORING
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FLOOR LEVELING AND TO ACHIEVE A SMOOTH AND
LEVEL SUBSTRATE.
9. ADHESIVES TO BE WATER RESISTANT, MILDEW RESISTANT, NON- STAINING TYPE TO SUIT PRODUCTS AND SUBFLOOR CONDITIONS INDICATED, THAT COMPLIES WITH FLAMMABILITY REQUIREMENTS FOR INSTALLED CARPET AND THAT IS RECOMMENDED AND APPROVED BY THE CARPET MANUFACTURER.
REFER TO AND FOLLOW CARPET MANUFACTURER'S CARPET TILE INSTALLATION INSTRUCTIONS.
10. SWEEP OR VACUUM THE ENTIRE AREA BEFORE APPLYING ADHESIVE. DO NOT USE SWEEPING
COMPOUNDS. AFTER CLEANING, EXAMINE SUBSTRATES FOR MOISTURE, ALKALINE SALTS
CARBONATION, OR DUST. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS
HAVE BEEN CORRECTED.
11. COMPLY WITH CARPET MANUFACTURER'S WRITTEN RECOMMENDED CARPET INSTALLATION METHODS.
WHERE TWO DIFFERENT CARPET STYLES MEET AT DOORWAYS, CENTER CARPET TRANSITION SEAM UNDER THE DOOR IN CLOSED POSITION. DO NOT BRIDGE BUILDING EXPANSION JOINTS WITH CARPET.
ADHERE CARPET TILES PER CARPET MANUFACTURER'S WRITTEN INSTALL INSTRUCTIONS.
12. CUT AND FIT CARPET TO BUTT TIGHTLY TO VERTICAL SURFACES, PERMANENT FIXTURES AND BUILT IN FURNITURE INCLUDING CABINETS, PIPES, OUTLETS, EDGINGS, THRESHOLDS, AND NOSINGS. BIND OR SEAL CUT EDGES AS RECOMMENDED BY CARPET MANUFACTURER. EXTEND CARPET INTO TOE SPACES, DOOR REVEALS, CLOSETS, OPEN-BOTTOMED OBSTRUCTIONS, REMOVABLE FLANGES, ALCOVES AND
SIMILAR OPENINGS.
13. PROTECT FINISHED FLOOR AGAINST DAMAGE FROM CONSTRUCTION OPERATIONS AND PLACEMENT OF EQUIPMENT AND FIXTURES DURING THE REMAINDER OF CONSTRUCTION PERIOD. USE PROTECTION
METHODS INDICATED OR RECOMMENDED IN WRITING BY FLOORING MANUFACTURER.
14. CONTRACTOR TO USE PAINT & PRIMER OF THE SELECTED PAINT MANUFACTURER. PLEASE REFER TO
FINISH SCHEDULE.
15. COORDINATE LOCATIONS OF FLOORING TRANSITIONS WITH FINISH PLANS AND SCHEDULE.
16. INSTALL VINYL SCHLUTER TRANSITION STRIP OR SIMILAR AT TRANSITIONS BETWEEN FLOORING MATERIAL's.
17. FLOOR TRANSITIONS WHICH OCCUR AT DOORS SHALL BE CENTERED BENEATH THE DOOR WHILE IN THE
CLOSED POSITION.
18. CONFIRM SHOWER-PAN AREA FLOOR FINISHES.\
19. ORDER (1) BOX OF SOLID CARPET TILE TO INSERT IN PHYSICAL THERAPY FLOORING FOR LABELING
AREAS. COORDINATE W/ OWNER FOR LOCATIONS.
20. CONTRACTOR TO USE PAINT & PRIMER OF THE SELECTED PAINT MANUFACTURER. REFER TO FINISH
SCHEDULE.
NOTE
TENANT SHALL PROVIDE FINAL REVIEW AND APPROVAL OF ALL NOTED FINISHES AND LOCATIONS.
MODIFICATIONS/CHANGES TO BE APPROVED PRIOR TO PROVIDING SUBMITTALS AND PROCURING
MATERIALS.
ROOM
NO. NAME FLOOR
FINISHES REMARKS
BASE N. WALL S. WALL E. WALL W. WALL CEILING MILLWORK
ROOM FINISH SCHEDULE
ROOM
NO. NAME FLOOR
FINISHES REMARKS
BASE N. WALL S. WALL E. WALL W. WALL CEILING MILLWORK
ROOM FINISH SCHEDULE
WD
WD
DOOR TYPE A - WOOD (INTERIOR)
WOOD DOOR FLUSH SOLID BY MARSHFIELD
5-PLY, RED OAK (TBD), PLAIN SLICED VENEER
FINISH (2) COATS SATIN POLYURETHANE STAIN
STAINED TO MATCH (TBD)
FRAME TYPE F-1 (INTERIOR DOOR)
(16 GA GALV. LEVEL 2 MODERATE DUTY) HOLLOW METAL KNOCK-DOWN
MITERED (WELDED AND GROUND SMOOTH) DRYWALL TYPE FRAME
FINISH (PRIME + (2) COATS FINISH)
MFR. CECO DOOR PRODUCTS - SERIES SU OR STEELCRAFT SERIES F
DOOR TRIM TO HAVE MITER CUTS AT 45°
1. THE COMPLETE ASSEMBLY OF FIRE RATED DOORS & FRAMES, INCLUDING HARDWARE, DOORS
AND FRAMES, SHALL BE LISTED AS BEING IN COMPLIANCE WITH THE SPECIFIED RATING.
2. ALL NEW DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON
DOORS REQUIRED TO BE ACCESSIBLE SHALL BE CAPABLE OF OPERATION WITH THE USE OF
ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, TIGHT PINCHING OR TWISTING OF THE
WRIST TO OPERATE PER SECTION 1008.1.9.2 MBC.
3. DOOR THRESHOLD SHALL NOT EXCEED ONE-HALF INCH (1/2") IN HEIGHT. THRESHOLDS
EXCEEDING ONE-QUARTER INCH (1/4") IN HEIGHT SHALL HAVE A 1:2 BEVEL.
4. ALL METAL DOOR FRAMES SHALL HAVE 3 RUBBER SILENCERS PER FRAME.
5. ALL KEYED DOORS ARE TO BE CORED AND KEYED WITH BEST COMPATIBLE CONSTRUCTION
CORES AND KEYS. THE (OWNER OR TENANT) WILL CORE AND KEY THE ENTRY DOORS WITH
THEIR PROPRIETARY CORES AND KEYS AFTER CONSTRUCTION AND PRIOR TO OCCUPANCY.
COORDINATE MASTERING REQUIREMENTS WITH THE (OWNER OR TENANT).
6. ALL DOORS SHALL HAVE COMMERCIAL GRADE HARDWARE WHICH COMPLIES WITH ALL
APPLICABLE BUILDING CODE AND ACCESSIBILITY REQUIREMENTS.
7. AT ALL MORTISE LOCK SETS - 1/4 TURN OF INTERIOR HANDLE RELEASES BOTH LOCK SET AND
DEADBOLT.
8. ALL DEADBOLTS SHALL BE AUTO RELEASE WITH 1/4 TURN OF HANDLE OR PUSH OF PADDLE.
9. ALL DOOR CLOSERS ARE TO BE SURFACE MOUNTED UNLESS NOTED OTHERWISE. ALL CLOSERS
TO HAVE INTEGRAL STOPS.
10. ALL FLUSHBOLTS ARE TO BE "AUTOMATIC" EXCEPT WHEN INDICATED AS BEING MANUAL BY
THE APPROPRIATE KEYED NOTE.
11. ALL EGRESS DOORS SHALL BE READILY OPENABLE FROM EGRESS SIDE AND SHALL NOT REQUIRE
A KEY OR SPECIAL KNOWLEDGE
12. ALL NEW DOORS REQUIRED TO BE ACCESSIBLE SHALL HAVE HARDWARE HEIGHT FROM 34
INCHES TO 48 INCHES PER SECTION 1008.1.9.1.
DOOR HARDWARE GENERAL NOTES
DOOR AND FRAME TYPE NOTES
CT-1,2,3
MKD
MKD 16
GB-1/PT-3
EPOXY FLOORING
EP-1
MANUFACTURER: SHERWIN WILLIAMS
FINISH: RESUFLOR DECO-FLAKE BC
COLOR: T.B.D.
PATTERN: T.B.D.
CT-2 (ACCENT)
CT-3 (ACCENT)
CT-1,2,3
CT-1,2,3
VERTICAL OUTSIDE CORNERS OF TILED WALLS ARE TO
HAVE BULLNOSE EDGING - SEE INTERIOR ELEVATIONS
FOR APPROX CT-1,2,3 PATTERN/LOCATIONS
NOTE:
FINAL ACCESSORIES SELECTIONS TO BE CONFIRMED BY OWNER.
BIDS & PERMITS03-26-25
RC235 CLASS ROOM EX VB-1
VB-1 AND PT-4 ON CLASS ROOM SIDE OF ADDITION
TO MATCH EXISTING (OR AS APPROVED BY OWNER)PT-4 - - EX
PT-4
MANUFACTURER: SHERWIN WILLIAMS
COLOR: T.B.D.
FINISH: T.B.D.
LOCATION: NEW WALLS ON CLASS ROOM SIDE
OF WOMEN'S TOILET ROOM ADDITION
ALTERNATE 01:
AS AN ALTERNATE PLEASE SUBMIT
COST REDUCTION FOR OMITTING
THE CERAMIC/PORCELAIN TILE AND
PAINTING THE EXISTING CMU WALLS
AND NEW CONSTRUCTION PER THE
FINISH SCHEDULE (2-3 COLORS)
PT-4
MANUFACTURER: AMERICA OLEAN
STYLE: COLOR STORY
SIZE: 4" x 12"
COLOR: 0082 WISDOM
LOCATION: WALLS
PATTERN: SEE INTERIOR ELEVATIONS
MANUFACTURER: AMERICA OLEAN
STYLE: COLOR STORY
SIZE: 4" x 12"
COLOR: 0075 LEMON ZEST
LOCATION: WALLS
PATTERN: SEE INTERIOR ELEVATIONS
CT-1,2,3 CT-1,2,3
CT-1,2,3CT-1,2,3 CT-1,2,3
GENERAL DEMOLITION NOTES:
1. THE BUILDER & HIS SUBCONTRACTORS SHALL VISIT THE EXISTING SITE AND SHALL
EXAMINE TO THEIR SATISFACTION ALL OF THE PHYSICAL CONDITIONS THAT
AFFECT THEIR CONTRACT PRICE, NOTING THE EXISTING SERVICE, LOCATION OF
EXISTING STRUCTURES AND EQUIPMENT (IF ANY), AS WELL AS AREAS AVAILABLE
FOR THE STORAGE OF MATERIAL. NO ADDITIONS TO THE CONTRACT PRICE SHALL
BE REQUESTED OR PERMITTED BY THE IGNORANCE OF ANY EXISTING CONDITIONS
OF THE SITE AND SURROUNDING AREA.
2. BUILDER SHALL LOCATE ALL EXISTING UTILITY LINES ON THE SITE AND RELOCATE
ALL ELECTRICAL EQUIPMENT DEVICES, CONDUIT, WIRING WORK, UNDERGROUND /
OVERHEAD UTILITIES, AND PLUMBING AS NECESSARY IN ORDER TO ACCOMPLISH
THE WORK OR DEMOLITION WITHIN THE CONSTRUCTION AREA OR ON THE SITE.
VERIFY EXACT REQUIREMENTS WITH EACH LOCAL UTILITY COMPANY BEFORE
STARTING WORK. CALL "MISS DIG" BEFORE STARTING CONSTRUCTION.
3. BUILDER SHALL COORDINATE WITH THE OWNER AND ALL SUB CONTRACTORS ON
ANY AND ALL NECESSARY TEMPORARY INTERRUPTIONS IN THE UTILITY
DISTRIBUTION SYSTEMS ON THE SITE OR WITHIN THE FACILITY UNDER
CONSTRUCTION. EVERY EFFORT SHALL BE MADE TO GIVE THE MAXIMUM
ADVANCE NOTICE IN ORDER TO PROVIDE A SATISFACTORY MEANS OF PROPER
SCHEDULING OF THE ACTIVITIES OF ALL CONCERNED.
4. IN PARTS WHERE ELECTRICAL OR MECHANICAL SYSTEMS CONFLICT OR
ALTERATIONS TO AN EXISTING SYSTEM IS REQUIRED BY THE GENERAL CONTRACT
WORK. NOTIFY AND COORDINATE ALL TRADES SO THAT THE PROPER
ARRANGEMENTS AND SCHEDULING CAN BE MADE FOR INSTALLATION, CUTTING,
REMOVING, TERMINATING, AND PATCHING OF SURROUNDING SYSTEMS AND
MATERIALS CAN BE PROPERLY COMPLETED.
5. BUILDER SHALL CHECK & VERIFY ALL CONDITIONS AT THE JOB SITE, REPORTING
ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY BEFORE PROCEEDING WITH
THE WORK.
6. BUILDER SHALL PROVIDE ALL NECESSARY BARRICADES, TEMPORARY SUPPORT OR
PARTITIONS, DUST SHIELDS AND SCAFFOLDING AS NECESSARY, TO PROTECT ALL
EXISTING, COMPLETED, OR NEW CONSTRUCTION FROM DAMAGE OR VANDALISM.
7. BUILDER SHALL TAKE NECESSARY MEASURES TO REMOVE ALL DEBRIS LEGALLY
FROM THE SITE AND TO DIRECT ALL SUB TRADES TO KEEP THE SITE CLEAN AT ALL
TIMES.
8. BUILDER SHALL CONTINUOUSLY MAINTAIN ADEQUATE PROTECTION OF ALL HIS
WORK FROM DAMAGE AND VANDALISM AND SHALL PROTECT THE OWNER OR
OTHER BUILDERS PROPERTY FROM INJURY, OR LOSS.
9. DO NOT SCALE DRAWINGS. USE ONLY THE DIMENSIONS PROVIDED ON THE PLANS.
IF OMISSIONS OR DISCREPANCIES EXIST, THE ENGINEER IS TO BE NOTIFIED
IMMEDIATELY. FAILURE TO DO SO BY ANY TRADE WILL RESULT IN THE COMPLETE
WAIVER OF ANY LIABILITY OF THE ENGINEER OR OWNER.
10. IF ANY INTERFERENCES OR VIOLATIONS APPEAR AND DEPARTURE FROM THE
DESIGN INTENT OF THE CONTRACT DOCUMENTS IS REQUIRED, THE BUILDER SHALL
NOTIFY THE ENGINEER BEFORE ENTERING INTO CONTRACT WITH THE OWNER.
FAILURE TO PROVIDE THE ENGINEER WITH AFOREMENTIONED NOTIFICATION WILL
RESULT IN THE BUILDER BEING HELD…