This document is a Scope of Work (SOW) for a federal contract opportunity to purchase and install warning signs, posts, and caution buoys along the Atlantic Intracoastal Waterway, Stone Bay, Verona, and Brown's Island Training Areas at MCB Camp Lejeune, North Carolina.

The contractor shall provide all necessary management, labor, equipment, materials, and permits to perform the work, which includes purchasing and installing 64 warning/information signs of 6 different types, 81 wooden posts, and 22 caution buoys with chains and anchors. The contractor must also provide UXO construction support and coordinate closely with the Range Maintenance Branch due to ongoing military training activities in the area. The work requires adherence to all applicable environmental laws and regulations. The contractor shall update documentation for all repaired, replaced, and installed signs and buoys. The federal agency involved is the Department of the Navy Naval Facilities Engineering Command.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

24-0702 Warning Sign and Caution Buoy Installation

Scope of Work

The Contractor shall provide all management, supervision, adequately trained personnel staff, labor, tools, equipment, materials, transportation, applicable permits, and certifications to perform the following work at MCB Camp Lejeune, North Carolina:

Scope of work: Purchase and Install warning signs, posts and caution buoys along the Atlantic Intracoastal Waterway, Stone Bay, Verona, and Brown’s Island Training Areas.

Contractor shall provide the following services:

Contractor shall purchase and install (64) Warning/Information signs at the designated locations.

Sign Types and quantities.

Type 1 (2) ea.

Type 2 (10) ea.

Type 3 (12) ea.

Type 4 (23) ea.

Type 5 (15) Type 6 (2) ea.

Signage specs listed in Enclosure 3

All attaching hardware and signpost shall be designed to withstand a corrosive environment (salt water).

The contractor shall remove any damaged signs and posts that are identified to be replaced.

Contractor shall be responsible to properly dispose of the removed signs, posts, and hardware.

Contractor shall purchase and install Eighty-one (81) 6”X6”X16’ post where required.

New posts and signs not installed shall be turned over to the government.

The contractor shall update Enclosure 1 for all repaired/replaced signs and identify any additional missing signage listed in Enclosure 1.

Enclosure 1 Sign Coordinates.

Enclosure 2 Sign Site Map.

Enclosure 3 Sign Specs.

Contractor shall purchase and install (22) twenty-two Caution Buoys, chains, and anchors.

Contractor shall install (18) eighteen buoys (SL-B700 Float Collar Buoy) at the designated locations in Enclosure 4 Caution Buoy Locations.

Contractor shall purchase and install (18) eighteen Regulatory wraps that read “LIVE FIRE IMPACT AREA” reference Enclosure 6 Buoy Specs (pg. 9).

Contractor shall purchase and install (54) fifty-four Regulatory wraps that read “UXO HAZARD AREA” reference Enclosure 6 Buoy Specs (pg. 9). This will require the removal of the existing wraps; the contractor shall replace any missing buoys first and then any damaged NTE (4) buoys.

Locations identified in Enclosure 4 Buoy Locations.

If additional buoys are required contractor shall identify location and materials needed to repair or replace and provide the government with a detailed cost estimate to replace the additional buoys.

The contractor shall update Enclosure 4 for all repaired/replaced/installed buoys and identify any additional missing buoys listed in Enclosure 4.

Buoy specifications identified in Enclosure 5.

Buoys shall be securely anchored to withstand incoming and outgoing tides as well as storm surge.

Buoys shall be anchored with chain and pyramid type anchor weight.

Chain size to be determined by weight/length/water depth.

Water depth between 2 feet and 20 feet

Anchor weight minimum of 100 lbs, please refer to manufactures recommendation.

Buoy shall meet all US Federal, State and Local regulations for regulatory buoys.

Contractor is responsible to complete and submit the Department of Homeland Security U.S.

Coast Guard form CG-2554 (Rev. 03-03).

The contractor shall update Enclosure 4 for all installed/repaired/replaced buoys and identify any additional missing buoys.

Enclosure 4 Buoy Coordinates.

Enclosure 5 Caution Buoy – Map.

Enclosure 6 Caution Buoy - Specs.

Contractor shall provide professional UXO Construction/Escort Support

The contractor shall provide professional UXO construction support necessary to minimize the explosive safety hazard or risk to human health and the environment during sign and buoy installation, including transiting to and from the work sites.

Where applicable, UXO avoidance can be used to relocate signage a safe distance from an identified hazard.

Where UXO avoidance is used, contractor shall provide detailed description and location of hazard found.

Contractor is responsible for obtaining all state and federal permits. Permitting requirements need to be coordinated with Base EMD and NCDNR

The contractor shall submit a workflow plan to Range Maintenance Branch (RMB) 451-1234 to schedule the dates and times for installation. Once the schedule has been approved by RMB, it will be forwarded to the ROICC Office for their approval and Notice To Proceed.

The works under this contract requires special attention to the scheduling and conduct of the work in connection with existing range/training operations. The following conditions apply:

Site closure due to military training in the adjacent range impact areas is expected to be less than 10 days during the Period Of Performance. This may include limited site access or no access at all. Contractor to closely coordinate all operations with the Range Maintenance Branch due to military training requirements during the entire construction schedule.

During site closure, all construction materials and equipment shall be removed from the range Surface Danger Zones (SDZs).

Contractor shall not have access to the site during Naval Gun Fire training or as directed by the Government.

The plan shall include an on/off schedule to deconflict with training activities. This is due to unforeseen training issues that arise and require the area to be cleared of all non-military personnel for a limited time.

All work shall be performed in accordance with all applicable Department of Defense guidance involving munitions and explosives of concern on active ranges.

The Contractor shall comply with all existing MCBCL, Federal, State and Local environmental laws and regulations; and to permit direct consumption/recycling by an authorized metals/wood recycler, dispose of non-hazardous waste at an approved Class 3 landfill. Removal includes all certifications required by law and transportation to an appropriate disposal site. Documentation of materials removed shall be provided to MCBCL (RMB).

If contaminants are suspected through odor or visual inspections during soil excavation, the contractor shall stop work and immediately contact the Environmental Quality Branch (EQB) at 451-9641, for further instructions.

The contractor shall ensure sediment does not leave a construction site of any size because of land-disturbing activities. Contractor shall be responsible for damages for failure to comply with Federal or State permits or if issued a Notice of Violation.

The contractor shall repair any Federally or privately owned item of property, damaged by any employee of the contractor or subcontractor(s), to its original condition at no cost to the Government. The contractor shall ensure that all underground utility lines are located and marked prior to the commencement of any activity that requires digging. The contractor shall bear all costs incurred as the result of damage to any functional underground object or utility (ex: power lines, water lines, sewer lines, telephone cables, television cables).

The Prime contractor shall coordinate the work schedule and access to the work areas with the Government Project Manager or if a Sub-Contractor with the Prime Contractor. Work areas shall be cleaned up and debris disposed of properly daily.

No equipment or material shall be stored on the work site without specific permission from the Government project manager.

The contractor shall not perform any work other than that specifically stated herein without written approval from the Government Contracting Authority. Any hidden damage or additional requirements discovered during the work shall be reported to the Government project manager immediately for direction and appropriate disposition.

BASE/RANGE ACCESS. Installation entry access/base passes shall be coordinated through the MCBCL Range Maintenance Branch (RMB). The contractor shall coordinate with the MCBCL RMB, at 910-451-1234 to schedule range access dates and times for installation. The contractor shall contact Range Control (Blackburn) at 910-451-3064 prior to occupying the work site and upon exiting the ranges daily.

Enclosure 1 Sign Coordinates

SIGN DESCRIPTION ACTIONS LON (DD) LAT (DD)

TYPE 1 Replace -77.43721639 34.6037295 TYPE 1 Replace -77.43557634 34.60655695 TYPE 3 Replace -77.43521943 34.60740248 TYPE 3 Replace -77.43460877 34.60889316 TYPE 3 Replace -77.43395044 34.61061917 TYPE 3 Replace -77.43356347 34.6123037 TYPE 3 Replace -77.43432614 34.61377597 TYPE 3 WITH TYPE 2 Replace -77.43428444 34.61458816 TYPE 3 WITH TYPE 2 Replace -77.43450065 34.61601725 TYPE 3 WITH TYPE 2 Replace -77.43807882 34.60264847 TYPE 3 WITH TYPE 2 Replace -77.43783263 34.60094052 TYPE 3 WITH TYPE 2 Replace -77.43804162 34.59541008 TYPE 4 Replace -77.43500997 34.61777404 TYPE 4 Replace -77.43393461 34.61829134 TYPE 4 Replace -77.43203386 34.61905422 TYPE 4 Replace -77.43013569 34.61968533 TYPE 4 Replace -77.42852753 34.62022022 TYPE 4 Replace -77.42655067 34.62011534 TYPE 4 Replace -77.42432262 34.6200454 TYPE 4 Replace -77.42316378 34.62027285 TYPE 4 Replace -77.42218328 34.62007726 TYPE 4 Replace -77.42000467 34.62009076 TYPE 4 Replace -77.41785442 34.61994554 TYPE 4 Replace -77.41575665 34.61960858 TYPE 4 Replace -77.4122491 34.61856791 TYPE 4 Replace -77.40517219 34.61390621 TYPE 4 Replace -77.39838921 34.6112427 TYPE 4 Replace -77.39293907 34.61290945 TYPE 4 Replace -77.38901814 34.61547622 TYPE 4 Replace -77.38601559 34.62008597 TYPE 4 WITH TYPE 2 Replace -77.38274763 34.62173656 TYPE 4 WITH TYPE 2 Replace -77.38032896 34.6221875 TYPE 4 WITH TYPE 2 Replace -77.37879744 34.62290407 TYPE 5 Replace -77.37753945 34.62350888 TYPE 5 Replace -77.37695983 34.62375176 TYPE 5 Replace -77.37536714 34.62488266 TYPE 5 Replace -77.37384864 34.62593997 TYPE 5 Replace -77.37243892 34.62593127 TYPE 5 Replace -77.37294793 34.62648039 TYPE 5 Replace -77.37310588 34.62761874 TYPE 5 Replace -77.37386719 34.62892516 TYPE 5 Replace -77.37493632 34.63082817 TYPE 5 Replace -77.37582427 34.63246352 TYPE 5 Replace -77.37647067 34.6341288 TYPE 5 Replace -77.37661651 34.63450109

TYPE 6 Replace -77.37697459 34.63458777 TYPE 1 Verify -77.37697834 34.63628406 TYPE 2 Verify -77.37511452 34.63719658 TYPE 2 Verify -77.37301381 34.63783024 TYPE 2 Verify -77.37131313 34.63839427 TYPE 2 Verify -77.37085416 34.63867733 TYPE 2 Verify -77.37043348 34.63890393 TYPE 2 Verify -77.37108711 34.63983209 TYPE 2 Verify -77.37186423 34.64472125 TYPE 3 Verify -77.37862907 34.64745151 TYPE 3 Verify -77.38092941 34.65007081 TYPE 3 Verify -77.38139127 34.65248687 TYPE 3 Verify -77.38162733 34.65402814 TYPE 3 Verify -77.38194224 34.65610922 TYPE 3 Verify -77.38281092 34.65776475 TYPE 3 Verify -77.38416897 34.65919394 TYPE 3 Verify -77.38486804 34.65991549 TYPE 3 Verify -77.38465483 34.66015808 TYPE 3 Verify -77.25520382 34.58007184 TYPE 3 Verify -77.25353882 34.58107349 TYPE 3 Verify -77.25263551 34.58157855 TYPE 3 Verify -77.2508288 34.58264689 TYPE 3 Verify -77.24900217 34.58371024 TYPE 3 Verify -77.24721712 34.58465525 TYPE 3 Verify -77.24522051 34.5856519 TYPE 3 Verify -77.24355544 34.5865419 TYPE 3 Verify -77.24155377 34.58741021 TYPE 3 Verify -77.23985626 34.58833812 TYPE 3 WITH TYPE 2 Verify -77.23780382 34.58932356 TYPE 3 WITH TYPE 2 Verify -77.23593712 34.59023357 TYPE 3 WITH TYPE 2 Verify -77.2352517 34.59049617 TYPE 3 WITH TYPE 2 Verify -77.23476568 34.59107306 TYPE 3 WITH TYPE 2 Verify -77.2340801 34.59193308 TYPE 4 Verify -77.2387418 34.59380399 TYPE 4 Verify -77.21357909 34.62006594 TYPE 4 Verify -77.21510311 34.61873101 TYPE 4 Verify -77.21678064 34.61742932 TYPE 4 Verify -77.21812477 34.61630497 TYPE 4 Verify -77.21983346 34.61494859 TYPE 4 Verify -77.22130567 34.6137227 TYPE 4 Verify -77.22286599 34.61253126 TYPE 4 Verify -77.22617594 34.60989242 TYPE 4 Verify -77.22697923 34.60894013 TYPE 4 Verify -77.25397067 34.58649139 TYPE 4 Verify -77.25312505 34.58747167 TYPE 4 Verify -77.2482784 34.59127551 TYPE 4 Verify -77.2470111 34.59238975

TYPE 4 Verify -77.24547791 34.59375229 TYPE 4 Verify -77.24400908 34.59507756 TYPE 4 Verify -77.23991858 34.59824509 TYPE 4 Verify -77.20746623 34.62684832 TYPE 4 Verify -77.20910733 34.62457371 TYPE 4 Verify -77.20964733 34.62313946 TYPE 4 Verify -77.23544921 34.60193332 TYPE 4 Verify -77.23388055 34.60320622 TYPE 4 Verify -77.23243533 34.60461206 TYPE 4 Verify -77.23099638 34.60584648 TYPE 4 Verify -77.22836596 34.60615603 TYPE 4 Verify -77.23127524 34.60078364 TYPE 4 Verify -77.23310738 34.59957808 TYPE 4 Verify -77.23502075 34.59937174 TYPE 4 Verify -77.24028138 34.59429862 TYPE 4 Verify -77.24038112 34.59719981 TYPE 4 Verify -77.23932378 34.59606357 TYPE 4 Verify -77.23857545 34.59703855 TYPE 4 Verify -77.23699179 34.5984701 TYPE 4 Verify -77.22946217 34.59817024 TYPE 4 Verify -77.2288521 34.59725017 TYPE 4 Verify -77.22826887 34.59680059 TYPE 4 Verify -77.22548878 34.59720186 TYPE 4 Verify -77.22396214 34.59804183 TYPE 4 Verify -77.22214555 34.59900296 TYPE 4 Verify -77.22043214 34.60016189 TYPE 4 Verify -77.21865378 34.60117525 TYPE 4 Verify -77.2168688 34.60225685 TYPE 4 Verify -77.21499883 34.60315353 TYPE 4 Verify -77.21314715 34.60419852 TYPE 4 Verify -77.21129383 34.60518356 TYPE 4 Verify -77.20939542 34.60608185 TYPE 4 Verify -77.20758541 34.60691855 TYPE 4 Verify -77.20560215 34.60785185 TYPE 4 Verify -77.20365544 34.60879185 TYPE 4 Verify -77.20178548 34.60958853 TYPE 4 Verify -77.19394383 34.61277688 TYPE 4 Verify -77.19189544 34.61358357 TYPE 4 Verify -77.19007209 34.61427023 TYPE 4 Verify -77.18801389 34.61499177 TYPE 4 Verify -77.18595187 34.61578607 TYPE 4 Verify -77.18406137 34.61646907 TYPE 4 Verify -77.18106545 34.61850684 TYPE 4 Verify -77.20307634 34.62540408 TYPE 4 Verify -77.24209099 34.59591522 TYPE 4 Verify -77.23366542 34.5940685 TYPE 4 Verify -77.22746708 34.59944682

TYPE 4 Verify -77.2254859 34.60079025 TYPE 4 Verify -77.22944527 34.60166457 TYPE 4 Verify -77.22501867 34.60248469 TYPE 4 Verify -77.22757071 34.60251023 TYPE 4 Verify -77.22518375 34.60417661 TYPE 4 Verify -77.22588407 34.60590384 TYPE 4 Verify -77.22695041 34.60745308 TYPE 4 Verify -77.22945617 34.60696554 TYPE 4 Verify -77.18057546 34.61937353 TYPE 4 Verify -77.18139574 34.62039069 TYPE 4 Verify -77.18326628 34.61983714 TYPE 4 Verify -77.18447108 34.6192025 TYPE 4 Verify -77.18530687 34.61905229 TYPE 4 Verify -77.18694791 34.61800409 TYPE 4 Verify -77.19271813 34.61515069 TYPE 4 Verify -77.19488266 34.61411101 TYPE 4 Verify -77.19637424 34.61360633 TYPE 4 Verify -77.19822334 34.61301404 TYPE 4 Verify -77.20200948 34.61268427 TYPE 4 Verify -77.20390396 34.61339835 TYPE 4 Verify -77.20255329 34.61469395 TYPE 4 Verify -77.20529103 34.6147166 TYPE 4 Verify -77.20586998 34.61516592 TYPE 4 Verify -77.20383708 34.61623046 TYPE 4 Verify -77.20536219 34.61658155 TYPE 4 Verify -77.20483561 34.61769999 TYPE 4 Verify -77.20678752 34.61810644 TYPE 4 Verify -77.20825906 34.61931494 TYPE 4 Verify -77.20815771 34.62084042 TYPE 4 Verify -77.20934562 34.62080988 TYPE 4 Verify -77.1912066 34.61697198 TYPE 4 Verify -77.19153042 34.61728186 TYPE 4 Verify -77.19313831 34.61785685 TYPE 4 Verify -77.19553402 34.61855302 TYPE 4 Verify -77.20566618 34.62600638 TYPE 4 Verify -77.20669303 34.62730408 TYPE 4 WITH TYPE 2 Verify -77.20653349 34.62704552 TYPE 4 WITH TYPE 2 Verify -77.20134453 34.62590418 TYPE 4 WITH TYPE 2 Verify -77.19818097 34.62505068 TYPE 4 WITH TYPE 2 Verify -77.1978559 34.62306408 TYPE 4 WITH TYPE 2 Verify -77.1979297 34.62131372 TYPE 4 WITH TYPE 2 Verify -77.19681347 34.6199274 TYPE 4 WITH TYPE 2 Verify -77.19668573 34.61963218 TYPE 4 WITH TYPE 2 Verify -77.2073442 34.63170994 TYPE 4 WITH TYPE 2 Verify -77.20683141 34.63088077 TYPE 4 WITH TYPE 2 Verify -77.20900445 34.62768596 TYPE 4 WITH TYPE 2 Verify -77.2094908 34.62258333

TYPE 4 WITH TYPE 2 Verify -77.21027063 34.62237986 TYPE 4 WITH TYPE 2 Verify -77.21069791 34.62245326 TYPE 4 WITH TYPE 2 Verify -77.25726686 34.58583541 TYPE 4 WITH TYPE 2 Verify -77.2543788 34.58586177 TYPE 4 WITH TYPE 2 Verify -77.25152205 34.58866428 TYPE 4 WITH TYPE 2 Verify -77.24999747 34.58993656 TYPE 4 WITH TYPE 2 Verify -77.23662298 34.59406825 TYPE 4 WITH TYPE 2 Verify -77.24637928 34.59524129 TYPE 4 WITH TYPE 2 Verify -77.24489179 34.59668412 TYPE 4 WITH TYPE 2 Verify -77.24327639 34.59783177 TYPE 4 WITH TYPE 2 Verify -77.24172172 34.59921269 TYPE 4 WITH TYPE 2 Verify -77.24009944 34.60051369 TYPE 4 WITH TYPE 2 Verify -77.23852604 34.60160642 TYPE 4 WITH TYPE 2 Verify -77.23704775 34.6029949 TYPE 4 WITH TYPE 2 Verify -77.23554521 34.60429364 TYPE 4 WITH TYPE 2 Verify -77.23405399 34.6056102 TYPE 4 WITH TYPE 2 Verify -77.23237287 34.60675892 TYPE 4 WITH TYPE 2 Verify -77.23076993 34.6079783 TYPE 4 WITH TYPE 2 Verify -77.22923643 34.60934967 TYPE 4 WITH TYPE 2 Verify -77.22791019 34.61072624 TYPE 4 WITH TYPE 2 Verify -77.2262272 34.6118118 TYPE 4 WITH TYPE 2 Verify -77.22467953 34.61306617 TYPE 4 WITH TYPE 2 Verify -77.22316571 34.61436497 TYPE 4 WITH TYPE 2 Verify -77.2216189 34.61565535 TYPE 4 WITH TYPE 2 Verify -77.21996305 34.61694769 TYPE 4 WITH TYPE 2 Verify -77.21873009 34.61815117 TYPE 4 WITH TYPE 2 Verify -77.21695399 34.61943665 TYPE 4 WITH TYPE 2 Verify -77.21546294 34.62078002 TYPE 4 WITH TYPE 2 Verify -77.21380258 34.62191008 TYPE 4 WITH TYPE 2 Verify -77.2124965 34.62324105 TYPE 4 WITH TYPE 2 Verify -77.21105201 34.62470074 TYPE 4 WITH TYPE 2 Verify -77.21011706 34.6264577 TYPE 4 WITH TYPE 2 Verify -77.20771818 34.62935911 TYPE 4 WITH TYPE 2 Verify -77.20655608 34.63119228 TYPE 4 WITH TYPE 2 Verify -77.19060379 34.61602715 TYPE 4 WITH TYPE 2 Verify -77.1885856 34.61682972 TYPE 4 WITH TYPE 2 Verify -77.19591966 34.61194524 TYPE 4 WITH TYPE 2 Verify -77.19789546 34.61111356 TYPE 4 WITH TYPE 2 Verify -77.19982383 34.61043687 TYPE 4 WITH TYPE 2 Verify -77.20694044 34.60726019 TYPE 4 WITH TYPE 2 Verify -77.22773217 34.59677188 TYPE 6 Verify -77.22702043 34.59669355 TYPE 7 Verify -77.23861304 34.5995673 TYPE 7 Verify -77.23697618 34.6007333 TYPE 8 Verify -77.22777216 34.60433671 TYPE 8 Verify -77.18223121 34.61737877 TYPE 8 Verify -77.18049544 34.62001192

TYPE 9 Verify -77.18084321 34.62040724 TYPE 9 Verify -77.22910689 34.59879478 TYPE 9 Verify -77.22446674 34.61122185 TYPE 9 Verify -77.21214414 34.62147137 TYPE 9 Verify -77.21122607 34.62221829 TYPE 9 WITH TYPE 2 Verify -77.20047574 34.61282916 TYPE 9 WITH TYPE 2 Verify -77.23460506 34.59494663 TYPE 9 WITH TYPE 2 Verify -77.20015048 34.62613189 TYPE 9 WITH TYPE 2 Verify -77.4086332 34.61577592

AIWW

FMC BOAT

FMC BOAT

0 500 1,000250 Meters

SIGNS

VERIFY

REPLACE

Enclosure 2 Sign Site Map Pg 1

STONE BAY

CREEK SECTOR

GREY POINT SECTOR

STONE BAY SECTOR

COURTHOUSE BAY SECTOR

FARNELL BAY SECTOR

COURTHOUSE BAY SECTOR

0 500 1,000250 Meters

SIGNS

VERIFY

REPLACE

Enclosure 2 Sign Site Map Pg 2

DRAWING NOT TO SCALE

Signs shall be lettered on one side. Lettering and background shall be of reflective material.

DANGER

LIVE FIRE IMPACT AREA

8’

4’

KEEP OUT

.080 Aluminum Sign

Letters appropriate for the sign size

Warning Sign (Type 1)

Red Reflective Background

White Reflective Background

For access call “Blackburn” 910-451-3064

Enclosure 3

.080 Aluminum Sign Signs shall be lettered on one side. Lettering and background shall be of reflective material.

U.S. GOVT.

PROPERTY

TRESPASSING

NO16”

13”

14 5/8”

Warning Sign (Type 2)

2Enclosure 3 reflective material.

DANGER

UNEXPLODED ORDNANCE

8’

4’

DO NOT ENTER

.080 Aluminum Sign

Letters appropriate for the sign size

Report any suspect item to 911 or 910-451-3064

Warning Sign(Type 3)

Red Reflective Background

White Reflective Background reflective material.

DANGER

UNEXPLODED ORDNANCE

24”

18”

DO NOT ENTER

.080 Aluminum Sign

Letters appropriate for the sign size

Report any suspect item to 911 or 910-451-3064

Warning Sign(Type 4)

Red Reflective Background

White Reflective

DANGER

KEEP OUT

CONSULT

NOTICE TO MARINERS

36”

36”

.80 Aluminum Sign

LIVE FIRE IMPACT AREA

2” Red Border

6” Black Letters

6” Black Letters

4” Black Letters

3” Black Letters

White Reflective Background

For access call “Blackburn”

910-451-3064 Letters appropriate for the sign size

Warning Sign (TYPE 5)

5Enclosure 3

EXPLOSIVE ORDNANCE DISPOSAL

Drawing not to scale

LIVE FIRE RANGE

8’

4’

Red Reflective Background

.80 Aluminum Sign

Letters appropriate for size of sign

Warning Sign(TYPE 6)

DANGER

DO NOT ENTERWhite Reflective

No anchoring, beaching, disembarking or other bottom/ground disturbing activity between Freeman Creek and

Bear Creek.

Drawing not to scale

8’

4’

Red Reflective Background

.80 Aluminum Sign

Letters appropriate for size of sign

Warning Sign(Type 7)

DANGER

White Reflective

No anchoring, beaching, disembarking or other bottom/ground disturbing activity between signs.

Drawing not to scale

8’

4’

Red Reflective Background

.80 Aluminum Sign

Letters appropriate for size of sign

Warning Sign(Type 8)

DANGER

White Reflective

Lag Bolts With Washer

4x8 Metal Sign

6x6 Post

Type 2

6 feet

6 feet

Ground Level

8 feet

Enclosure 3 9

6x6 Post

Sign

Enclosure 3 10

6x6 Post

Lag Bolts With Washer

4x8 Metal Sign

Ground Level

Notes:

1. All lumber treated

2. All hardware galvanized

3. Lag bolts to be 3” long ½” dia.

4. Washers to be flat ½” dia.

6’

6’

4’

Enclosure 3 11

Type 2

6 feet

6 feet

Ground Level

4 feet

8 feet

Enclosure 3 12

Type 2

6 feet

6 feet

Ground Level

18 inches

24 inches

Type 4

Enclosure 3 13

Enclosure 4 Buoy Coordinates

Type LON (DD) LAT (DD)

LIVE FIRE -77.38239955 34.65777313

LIVE FIRE -77.3802265 34.65766726

LIVE FIRE -77.37813569 34.65716618

LIVE FIRE -77.37610736 34.65650581

LIVE FIRE -77.37417987 34.65566354

LIVE FIRE -77.37236133 34.65466927

LIVE FIRE -77.37065798 34.65354416

LIVE FIRE -77.36907646 34.65230349

LIVE FIRE -77.3676252 34.6509585

LIVE FIRE -77.36631561 34.64951767

LIVE FIRE -77.36518222 34.64797959

LIVE FIRE -77.36445242 34.64628496

LIVE FIRE -77.36391643 34.64454063

LIVE FIRE -77.36382803 34.64274336

LIVE FIRE -77.36422638 34.64097511

LIVE FIRE -77.36509149 34.63932456

LIVE FIRE -77.36637976 34.63787487

LIVE FIRE -77.36838473 34.63828202

UXO -77.42748362 34.62032214

UXO -77.42314564 34.61852428

UXO -77.42168949 34.6179492

UXO -77.42026632 34.61738246

UXO -77.41880994 34.61679833

UXO -77.41737434 34.61617771

UXO -77.41598287 34.61557423

UXO -77.41458104 34.61498897

UXO -77.41310243 34.61438718

UXO -77.41166795 34.61380253

UXO -77.4102218 34.61319105

UXO -77.40883122 34.61261452

UXO -77.40734204 34.61202188

UXO -77.40593981 34.61141849

UXO -77.40446158 34.61082561

UXO -77.40306977 34.61020395

UXO -77.40173039 34.60950912

UXO -77.4003682 34.60877867

UXO -77.39901796 34.60808403

UXO -77.39765659 34.60738057

UXO -77.39635206 34.60675712

UXO -77.39509001 34.60761132

UXO -77.39384998 34.60847408

UXO -77.39264236 34.60932718

UXO -77.39141343 34.61019872

UXO -77.39019512 34.61106102

UXO -77.38901909 34.61187741

Enclosure 4 Buoy Coordinates

UXO -77.38780073 34.61273969

UXO -77.38656055 34.61360238

UXO -77.38532008 34.61445606

UXO -77.38410138 34.61530929

UXO -77.38288318 34.61618054

UXO -77.38165328 34.61702495

UXO -77.38048926 34.6178861

UXO -77.37921571 34.61873135

UXO -77.37799689 34.61958453

UXO -77.37676792 34.62046494

UXO -77.37551635 34.62131873

UXO -77.37430835 34.62217167

UXO -77.37310136 34.62306063

UXO -77.37188241 34.62391375

UXO -77.37163467 34.62517169

UXO -77.37136743 34.62651114

UXO -77.37110981 34.62780533

UXO -77.37086385 34.62912634

UXO -77.37063891 34.6304199

UXO -77.37042512 34.63172225

UXO -77.37015785 34.6330617

UXO -77.36987942 34.63439235

UXO -77.3704051 34.63561722

UXO -77.37094119 34.63682385

UXO -77.37141394 34.63810383

UXO -77.42457324 34.61913541

UXO -77.42597253 34.61972653

BUOY

LIVE FIRE

UXO 0 500 1,000250

Meters

Enclosure 5 Buoy Site Map

Sealite USA LLC

USA

+1 (603) 737 1311

Sealite Asia Pte Ltd Singapore

+65 6829 2243

Sealite United Kingdom Ltd

UK

+44 (0) 1502 588026

Sealite Pty Ltd Australia

+61 (0)3 5977 6128

SL-B700 Float Collar Buoy Regulatory and Channel/Navigation Markers

The SL-B700 Buoy is rotationally-molded in one piece from strong, durable UV-stabilized polyethylene and is filled with closed-cell polyurethane. It is available in three different configurations: a red nun and green can navigation buoys, as well as a regulatory style buoy, which meet federal, state, and local requirements. A large mooring attachment point accommodates a 5/8 inch (16mm) shackle or 1/2 inch (12mm) cable.

Sealite’s SL-B700 Buoy incorporates stainless steel interconnected mooring and lifting eye (see below) for additional strength while being deployed and retrieved. The top section has three threaded M6 inserts, molded into the buoy to allow easy mounting of the SL-60 Large Base or SL-70 2-3NM Marine Lanterns.

Regulatory signage and custom graphics are available, which will hold up under heavy UV exposure without peeling and fading. Vinyl wraps and decal restoration kits are also available to repurpose older buoys (see back).

Foam filled with closed-cell polyurethane

Cement filled base improves performance

Stainless steel mooring eye

Interconnected mooring & lifting eye

Optional solar light available

Made from strong, durable, UV-stabilized, virgin polyethylene

Cost Effective Low maintenance costs

Withstand heavy UV exposure -no peeling or fading

Optional Mold-in graphics

Mooring equipment & chains

Vinyl decal restoration kits and wraps to refurbish or repurpose existing buoys

Features Molded from strong, durable UV-stabilized polyethylene

Interconnected mooring and lifting eye for additional strength

Easy mounting of solar marine lanterns

Regulatory signage available

Applications Navigation channels, harbor approaches and port entrances

Regulatory marking of hazards, mooring fields, cautionary zones

Reliable Excellent buoyancy & stability

Certifications Meets U.S. federal, state and local regulations

Flexible Configurations Channel Markers - Green Can or Red Nun

Regulatory Buoy - White with Orange Stripes

Above:

Structural integrity of SL-B700 is reinforced through the use of an interconnected stainless steel mooring and lifting eye

Above:

SL-B700 is available in green can and red nun style for channel marking configurations (shown in region B colors)

We believe technology improves navigationTM

Sealite USA LLC

USA

+1 (603) 737 1311

Sealite Asia Pte Ltd Singapore

+65 6829 2243

Sealite United Kingdom Ltd

UK

+44 (0) 1502 588026

Sealite Pty Ltd Australia

+61 (0)3 5977 6128

SL-B700_DATA_EN_V2-0

Technical Specifications*

SL-B700 Buoy

General Characteristics Available Colors Red, Green, White, Yellow, Orange Nominal Freeboard (in/mm) 43.5 (1105) Nominal Draft (in/mm) 10.5 (267) Maximum Mooring Load (lb/kg) 132 (60) Submergence (lb/in, kg/cm) 21.6 (3.8)

Physical Characteristics Material Rotationally-molded UV-stabilized virgin polyethylene Wall Thickness (in/mm) 0.25 (7) Filling Closed-cell polyurethane foam Height (in/mm) 54 (1372) Collar Diameter (in/mm) 28 (700) Diameter (in/mm) 12 (305) Net Weight (lb/kg) 95 (43) Product Life Expectancy 12+ years

Certifications Quality Assurance ISO9001:2015

Intellectual Property Trademarks SEALITE® is a registered trademark of

Sealite Pty Ltd

Warranty 1 year

Lantern Options Sealite SL-15, SL-60 Large Base or SL-70 lantern**

Options Available • Mold-in graphics

• Vinyl wraps

• Reflective band

• Side attachment

Technical Illustration

Regulatory Wraps & Restoration Kits

Vinyl Wrap Kit (Part No.: SL-BWRAP700)

Decal Restoration Kit

Material Two USCG approved retroreflective orange bands, regulatory black messages, and orange symbols on heavy-duty white vinyl material

Two each: retroreflective orange bands, regulatory black messages, and orange symbols

Options Custom graphics or logo Silver retroreflective band

Custom graphics or logo Silver retroreflective band

Left:

Vinyl Wrap Kit example

Right:

Decal Restoration

Kit example

SL-B700 Can and Regulatory Buoy Dimensions

**Three threaded inserts allow direct mounting of the SL-60 Large Base and SL-70 Marine Lanterns onto the SL-B700 Can. The SL-B700 Nun buoy requires a mounting plate (MC-11) for the SL-60 and SL-70. The SL-15 requires self-tapping screws.

† Subject to standard terms and conditions.

* Specifications subject to change or variation without notice.

(10.4") 265mm

1370mm (53.9")

Dia 700mm

22mm (0.87")

M6 thread on PCD 200mm (7.9")

Dia 22.5mm (0.88")

Dia 22.5mm (0.88")

Zone Rev Model Rev

ECR

No. Description Date:- Drawn:- Approved:-

Notes:- Break all sharp edges.1.

Use 3D Model for Machining.2.

Refer Drawing for GEO Tol and Dimension Tol.3.

Part Nº .4.

Nominal Water Level (without mooring)

178.696 A3SolidWorksmm

Drawn in:-Units

Sheet Size:-naturalFinish:-

SLB700 MK2 CAN - TOOL, US

Material <not specified> -

Wt(Kg) each:-

Material/Quantity

J Putaansuu

A Leitch

S Wright

N/A

000206-000

N/A

General Tolerances

X.XX

X.X X

±0.1 ±0.3 ±1.2

X.X X

±0.5° ±1.0°

±0.5 ±2.0

Angular

X.X Drawing Rev:-

Drawn:-

11/7/2018

11/7/2018

Approved:-

Checked:-

11/7/2018

000206-000

Qty per Ass'y:-

Drawing No:-

File Name:-

Sheet ScaleProjection

Next Ass'y:-

1:20 1 of 1

Model Rev:-

Sealite

A

B

C

D

E

F

G

9 8 7 6

Linear Radii X

[54in] 1372mm

Dia [0.88in] 22.5mm

Dia [0.88in] 22.5mm

[10.5in] 267mm

[12in] 305mm

SL-B700 Nun Buoy Dimensions

(10.4") 265mm

1370mm (53.9")

(0.88") Dia 22.5mm

Dia 22.5mm (0.88")

162.125 A3SolidWorksmm

Drawn in:-Units

Sheet Size:-naturalFinish:-

SLB700 MK2 CONE - TOOL, US #2

Material <not specified> -

Wt(Kg) each:-

Material/Quantity s.wright

N/A

000254-000

N/A

General Tolerances

X.XX

X.X X

±0.1 ±0.3 ±1.2

X.X X

±0.5° ±1.0°

±0.5 ±2.0

Angular

X.X Drawing Rev:-

Drawn:-

Approved:-

Checked:-

07/11/2018

000254-000

Qty per Ass'y:-

Drawing No:-

File Name:-

Sheet ScaleProjection

Next Ass'y:-

1:20 1 of 1

Model Rev:-

Sealite

A

B

C

D

E

F

G

9 8 7 6

Linear Radii X

Zone Rev Model

Rev

ECR

No. Description Date:- Drawn:- Approved:-

Notes:- Break all sharp edges.1.

Use 3D Model for Machining.2.

Refer Drawing for GEO Tol and Dimension Tol.3.

Part Nº .4.

Nominal Water Level (without mooring)

Nominal Water Level (without mooring)

Dia 700mm

22mm (0.87")

M6 thread on PCD 100mm (7.9")

[54in] 1372mm

Dia [0.88in] 22.5mm

Dia [0.88in] 22.5mm

[10.5in] 267mm

[5.3in] 305mm

[12in] 305mm

Collar Dia [28in] 700mm

Collar Dia [28in] 700mm

Mooring Weight

Swivel

Chain

Shackle 16mm or 5/8" Typical

NOTES:-

Provided for informational purposes only. The design and selection of the1.

mooring system should be determined by a qualified professional familiar with the specific application.

Total weight of the buoy equipment and wet weight of the mooring line2.

should not exceed 60 kg The buoy can be moored using cable or rope where service conditions allow.3.

Attach rope to the buoy using a tail chain of 1/2" proof coil chain [13mm ISO chain] with length to suit buoy loading.

Zone Rev Model Rev

ECR

No. Description Date:- Drawn:- Approved:-

Recommended Length of Chain

[m] Maximum Water

Depth [m]

Best Practice 3 x Water Depth 18 For use where current < 2 knots 2 x Water Depth 22

Maximum Water Depth Recommended Chain Size [mm]Meters Feet

3 to 8 10 to 26 16

8 - 14 26 - 46 13

14 - 22 46 - 72 10

Minimum Tail Chain (Note 3) Length [m] Air Weight [kg]

Buoy Only Up to 3 Up to 9.5 With SL15 3.5 11 With SL60 4 12.5

A4SolidWorksmm Drawn in:-Units

Sheet Size:-

N/AFinish:-

SL-B700 Mk2 Mooring Diagram

Wt(Kg) each:-

Material/Quantity

N/A

N/A

General Tolerances Linear X X.X

X.XX

±1.2 ±0.3 ±0.1

Angular X X.X

±1.0° ±0.5°

±2.0 ±0.5

Radii X X.X 0Drawing Rev:-

Drawn:-

Approved:-

Checked:-

SL-B700 Mooring Diagram

Qty per Ass'y:-

Drawing No:-

File Name:-

Sheet ScaleProjection

Next Ass'y:-

1:20 1 of 1

Model Rev:-

Sealite 389.843

A

B

C

D

E

F

G

5 4 3 2 1

'''''Y"•-·••111-.. •-·••W••···--··-, ,-...-----... -- -·

5/8" Anchor Shackle, Bolt Type, Forged Carbon Steel, Galvanized Catalog Number: 5391035

Features Specifications

UPC 020418075544

Trade Size Fractional 5/8 In

Working Load limit Short Ton 3-i/4 T

Length Tolerance(+/-) 1/Bin

Width Tolerance(""/-) 1/8 in

B Dimension 3/4 in

C Drmenslon 2-7/16 in

□ Dimension 1-1(16in

E Dimension 1-9/16in

F Dimension 1-7/181n

Weight Each {lbs.) 1.30 b

Made in USA Yes

5/8" Eye & Eye Swivel, Drop Forged Carbon Steel, Galvanized Catalog Number: 3631035

Features Specifications

UPC 02041806994 9

Trade Size Fractional 5/8 in

Working load limit 520:)lt>

A Dimension

B Dimension 1-5/8 in

C Dimension 1-314 in

0 Oi�nsion 2-3JB in

L Dimension ''"

R Dimension 6-3/4 in

Weight Each (lbs.) 2.521b

Made in USA v ..

Find a □is1ributor 'I

Specifications:

Material: Iron

Color: Red

Weight: 150 lbs

Coating: Painted https://www.bing.com/images/search?q=seachoice+150+lb+pyramid+anchor&id=201DC3AB9ED25A0DA06BDFD52FA844C294A97806&FORM=IQFRBA

LIVE

FIRE

IMPACT

AREA

HAZARD

UXO

AREA

RTAM Warning Sign and Buoy Installation_SOW
RTAM Warning Sign and Buoy Installation_Encl 1 Sign Coord
Sheet1
RTAM Warning Sign and Buoy Installation_Encl 2 Sign Site Map
Signs Beach AIWW
Signs River
RTAM Warning Sign and Buoy Installation_Encl 3 Sign Specs
Warning Sign (Type 1)
Warning Sign (Type 2)
Warning Sign(Type 3)
Warning Sign(Type 4)
Warning Sign (TYPE 5)
Warning Sign(TYPE 6)
Warning Sign(Type 7)
Warning Sign(Type 8)
Slide Number 9
Slide Number 10
Slide Number 11
Slide Number 12
Slide Number 13
RTAM Warning Sign and Buoy Installation_Encl 4 Buoy Coord
Sheet1
RTAM Warning Sign and Buoy Installation_Encl 5 Buoy Site Map
RTAM Warning Sign and Buoy Installation_Encl 6 Buoy Specs

File details come from the government source that posted it. Updated .