This document is a set of mechanical and plumbing drawings for the Muskegon Correctional Facility Greenhouse project in Michigan, prepared by the State of Michigan's Department of Technology, Management and Budget, State Facilities Administration, Design and Construction Division. The project involves the demolition and installation of underground utility piping systems to support a new greenhouse structure. Key work includes the removal and capping of existing buried domestic cold water piping, steam piping, and steam condensate piping back to the main connections in the existing building basement, along with the installation of new direct buried piping systems in the same categories. The contractor must perform ground penetrating radar surveys prior to construction to verify existing underground utility locations and conduct all excavation using hydrovac methods. New piping must be installed at a minimum depth of 42 inches from grade, include tracer wire, and feature sand base layers compacted to MDOT Class II standards. Interior systems include steam unit heaters, pressure reducing valves, domestic water heaters, exhaust fans, re-circulation fans, louvers, dampers, a greenhouse control panel, and associated accessories, all to be installed per manufacturer specifications and connected to the facility's STARNET 2.0 system.
Additional project requirements include the installation of below-grade sanitary piping, vent piping, trench drains, catch basins, domestic water meters, wall hydrants, and hose bibs. All concrete and asphalt surfaces disturbed during construction must be patched to be flush and match existing conditions, and all green areas must be re-graded and seeded with a specified seed mix at eight pounds per 1,000 square feet. Steam and steam condensate piping must be sloped appropriately to ensure proper drainage away from the new greenhouse toward the existing building. The contractor is responsible for coordinating with the domestic water service provider for water meter installation and with CommTech Design (Brett Emerson, 616-446-4545) for connections to the facility's security IT rack. Existing below-grade exterior wall penetrations must be modified to accommodate new piping and sealed water-tight upon completion.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
X-CW
X-CW
X-CW
X-CW, X-SC,
& X-STM UP
1 2 3
X-CWX-STMX-SC
X-STM
X-STM
X-STM
X-SC
X-SC
X-SC
2 3
1 2 3
1 2 3
2 3
X-GREENHOUSE
X-BUILDING
DEMOLITION NOTES
DISCONNECT, REMOVE, & DEMO EXISTING BURIED
DOMESTIC COLD WATER PIPING, VALVES, FITTINGS,
AND ALL ASSOCIATED ACCESSORIES IN THEIR
ENTIRETY. CONTRACTOR TO DEMOLISH DOMESTIC
COLD WATER MAIN BACK TO MAIN IN EXISTING
BUILDING BASEMENT AND CAP.
DISCONNECT, REMOVE, AND DEMO EXISTING
BURIED STEAM CONDENSATE PIPING, VALVES,
FITTINGS, AND ALL ASSOCIATED ACCESSORIES IN
THEIR ENTIRETY. CONTRACTOR TO DEMOLISH
STEAM CONDENSATE PIPING BACK TO MAIN IN
EXISTING BUILDING BASEMENT AND CAP.
DISCONNECT, REMOVE, AND DEMO EXISTING
BURIED STEAM PIPING, VALVES, FITTINGS, AND ALL
ASSOCIATED ACCESSORIES IN THEIR ENTIRETY.
CONTRACTOR TO DEMOLISH STEAM PIPING BACK
TO MAIN IN EXISTING BUILDING BASEMENT AND
CAP.
EXISTING BELOW GRADE EXTERIOR WALL
PENETRATIONS TO BE MODIFIED AS REQUIRED TO
BE REUSED FOR NEW PIPING SHOWN ON NEW
DRAWINGS.
GENERAL DEMOLITION NOTES
1. CONTRACTOR TO PROVIDE GROUND PENETRATING RADAR SURVEY PRIOR
TO CONSTRUCTION TO VERIFY LOCATIONS OF ALL EXISTING UNDERGROUND
UTILITIES IN THE AREA OF EXISTING DIRECT BURIED PIPING. ALL EXCAVATION
IS TO BE HYDROVAC-EXCAVATION.
2. CONTRACTOR TO BACKFILL AND RE-GRADE ALL GREEN AREAS AFFECTED BY
CONSTRUCTION TO MATCH EXISTING AFTER ALL DEMOLITION/NEW WORK IS
COMPLETE.
P e t t i t t Y a s t e
S t r a u b
200S
LAWSON,C MICHIGAN
UITE
48017-1311
F A X248-658-7781
248-658-7777 P H O N E
C850 NORTH ROOKS ROAD
MUSKEGON CORRECTIONAL
FACILITY
GREENHOUSE
M A
T R
I X
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P
L A
C H
R
A
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
MP2
BELOW GRADE -
PARTIAL SITE PLAN -
MECHANICAL/PLUMBING
DEMOLITION
N
BELOW GRADE - PARTIAL SITE PLAN -
MECHANICAL/PLUMBING DEMOLITION
SCALE: 1/8" = 1'-0"
0 1 5 10 20
CW
CW
CW
CW
1" CW, 1-1/2" STM,
& 1" SC UP
SC
SC
SC
STM
1" CW , 1-1/2" STM,
& 1" SC (BURIED)
2 3
1" CW , 1-1/2" STM,
& 1" SC (BURIED)
1 2 3
SC
STM
STM
STM
2 3
1" CW , 1-1/2" STM,
& 1" SC (BURIED)
1 2 3
1" CW , 1-1/2" STM,
& 1" SC (BURIED)
1 2 3
1" CW , 1-1/2" STM,
& 1" SC (BURIED)
1 2 3
STM
SC
CW
X-BUILDING
SLOPE
SLOPE
SLOPE
SLOPE
SLOPE
SLOPE
PIPE
ANCHOR
(TYP.)
PIPE ANCHOR
(TYP.)
2' x 2' x 4' WIDE CONCRETE
BLOCK ENCOMPASSING
PIPING ANCHORS
2' x 2' x 4' WIDE CONCRETE
BLOCK ENCOMPASSING
PIPING ANCHORS
5'-0"
10'-0"
MECHANICAL/PLUMBING KEY NOTES
INSTALL NEW DIRECT BURIED DOMESTIC COLD WATER PIPING, VALVES, FITTINGS, AND ALL
ASSOCIATED ACCESSORIES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS IN
THE LOCATION SHOWN. CONNECT NEW DOMESTIC COLD WATER PIPING TO EXISTING COLD
WATER PIPING IN EXISTING BUILDING BASEMENT. MODIFY EXISTING PIPING AS REQUIRED
FOR NEW CONNECTION.
INSTALL NEW DIRECT BURIED STEAM CONDENSATE PIPING, VALVES, FITTINGS, AND ALL
ASSOCIATED ACCESSORIES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS IN
THE LOCATION SHOWN. CONNECT NEW STEAM CONDENSATE PIPING TO EXISTING STEAM
CONDENSATE PIPING IN EXISTING BUILDING BASEMENT. MODIFY EXISTING PIPING AS
REQUIRED FOR NEW CONNECTION.
INSTALL NEW DIRECT BURIED STEAM PIPING, VALVES, FITTINGS, AND ALL ASSOCIATED
ACCESSORIES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS IN THE LOCATION
SHOWN. CONNECT NEW STEAM PIPING TO EXISTING STEAM PIPING IN EXISTING BUILDING
BASEMENT. MODIFY EXISTING PIPING AS REQUIRED FOR NEW CONNECTION.
ROUTE NEW DOMESTIC COLD WATER PIPING, STEAM PIPING, AND STEAM CONDENSATE
PIPING THOUGHT EXISTING BELOW GRADE EXTERIOR WALL PENETRATIONS. MODIFY
PENETRATIONS AS REQUIRED FOR NEW PIPING. PATCH EXISTING BELOW GRADE WALL
PENETRATIONS TO MATCH EXISTING AND SEAL WATER TIGHT ONCE NEW PIPING HAS BEEN
INSTALLED.
WELD NEW PIPE ANCHORS TO NEW STEAM AND STEAM CONDENSATE PIPING IN THE
LOCATION SHOWN. POUR NEW 2' TALL x 2' DEEP x 4' WIDE CONCRETE SLAB ENCOMPASSING
THE NEW DIRECT BURIED PIPING HAVING THE NEW PIPE ANCHORS CENTERED IN THE NEW
CONCRETE SLAB. CONCRETE SLAB IS TO BE COMPLETELY BURIED.
CONTRACTOR TO INSTALL EXPANSION LOOP AND ALL ASSOCIATED ACCESSORIES AS SHOWN
IN THE MIDDLE OFF THE NEW PIPING RUN. CONTRACTOR TO DIMENSION THE EXACT
LOCATION OF EXPANSION LOOP AND DOCUMENT THE LOCATON ON THE AS-BUILT DRAWINGS.
GENERAL MECHANICAL/PLUMBING NOTES
1. CONTRACTOR TO PROVIDE GROUND PENETRATING RADAR SURVEY PRIOR TO CONSTRUCTION TO VERIFY
LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES IN THE AREA OF EXISTING DIRECT BURIED PIPING.
ALL EXCAVATION IS TO BE HYDROVAC-EXCAVATION.
2. AFTER NEW DIRECT BURIED PIPING IS INSTALLED, CONTRACTOR TO PATCH ALL CONCRETE/ASPHALT AS
REQUIRED REQUIRED TO BE FLUSH AND MATCH EXISTING.
3. AFTER NEW DIRECT BURIED PIPING IS INSTALLED, CONTRACTOR TO RE-GRADE AND SEED ALL GREEN
AREAS AFFECTED BY CONSTRUCTION TO MATCH EXISTING.
4. SLOPE NEW STEAM CONDENSATE PIPING AWAY FROM THE NEW GREENHOUSE AND TOWARDS THE
EXISTING BUILDING.
5. SLOPE NEW STEAM PIPING AWAY FROM NEW GREENHOUSE AND TOWARDS THE EXISTING BUILDING.
6. ALL NEW DIRECT BURIED PIPING TO BE INSTALLED WITH TRACER WIRE.
7. ALL NEW DIRECT BURIED PIPING TO BE INSTALLED AT A MINIMUM DEPTH OF 42" FROM GRADE TO THE TOP
OF THE NEW PIPING.
SEEDING SCHEDULE
CONTRACTOR TO SUPPLY 6" OF TOPSOIL OVER ALL
DISTURBED AREAS. SEED ALL DISTURBED AREAS
WITH THE FOLLOWING SEED MIX:
40% KENTUCKY BLUEGRASS
25% CREEPING FESCUE
20% PERENNIAL RYEGRASS
15% CHEWING FESCUE
APPLY AT A RATE OF 8 LBS PER 1,000 SQUARE FEET
OR 350 LBS PER ACRE.
1 DIRECT BURIED PIPING DETAIL
SCALE: NTS
GENERAL NOTES:
1. ALL DIRECT BURIED PIPING TO BE INSTALLED
AT LEAST 42" BELOW GRADE FROM THE TOP OF
PIPE.
2. CONTRACTOR TO HYDROVAC-EXCAVATE ALL
LOCATIONS FOR NEW DIRECT BURIED PIPING.
CONTRACTOR TO PROVIDE SAND BASE LAYER
WHERE NEW DIRECT BURIED PIPING IS TO BE
INSTALLED. SAND BASE LAYER SHALL BE MDOT
CLASS II SAND COMPACTED TO 98% MAXIMUM.
SC
X-GRADEX-GRADE 42
" M
IN
STM
NEW SAND
BASE LAYER
X-SOIL
X-SOIL
X-SOIL
CW
NEW INFILL
P e t t i t t Y a s t e
S t r a u b
200S
LAWSON,C MICHIGAN
UITE
48017-1311
F A X248-658-7781
248-658-7777 P H O N E
C850 NORTH ROOKS ROAD
MUSKEGON CORRECTIONAL
FACILITY
GREENHOUSE
M A
T R
I X
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P
L A
C H
R
A
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
MP3
BELOW GRADE -
PARTIAL SITE PLAN -
MECHANICAL/PLUMBING
NEW
N
BELOW GRADE - PARTIAL SITE PLAN -
MECHANICAL/PLUMBING NEW
SCALE: 1/8" = 1'-0"
0 1 5 10 20
TD-1
CATCH
BASIN
TD-1
1" CW, 1" SC, & 1-1/2" STM
(BURIED, REFER TO PARTIAL
SITE PLAN FOR CONTINUATION)
1" CW, 1" SC, &
1-1/2" STM UP
SA
N
4"
4"
FCO
2" SAN UP
TO SK-1
4"
2" V UP
V
4" SAN TO DRYWELL
(REFER TO CIVIL FOR
CONTINUATION)
SAN
SAN SAN
4"
4"
CO (INSTALL WITHIN 5'
OF BUILDING)
FINISH FLOOR =100'-0"
I.E.=98'-6"
GENERAL MECHANICAL/ PLUMBING NOTES
1. INSTALL NEW BELOW GRADE SANITARY PIPING, VENT PIPING, AND ALL ASSOCIATED ACCESSORIES IN THE
LOCATION SHOWN.
MECHANICAL/ PLUMBING KEY NOTES
INSTALL NEW TRENCH DRAIN, CATCH BASIN, SANITARY PIPING, AND ALL ASSOCIATED
ACCESSORIES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS IN THE LOCATION
SHOWN.
ROUTE NEW DOMESTIC COLD WATER PIPING, STEAM PIPING, AND STEAM CONDENSATE
PIPING UP THROUGH GREENHOUSE FLOOR IN THE LOCATION SHOWN.
50'-0 5/8" 24 5/8" 24'-0
1'-0"
ZURN MODEL #Z887-12-HD, 12"x24" CATCH BASIN w/P12-PS PERFORATED STAINLESS
STEEL GRATE
ZURN MODEL
P12-PS
PERFORATED
STAINLESS STEEL
GRATE.
24 5/8" 24'-0"
3" SAN
OUTLET
ZURN MODEL #FT
FOUL AIR TRAP
ZURN MODEL #Z887-12-HD,
12"x24" CATCH BASIN w/P12-PS PERFORATED
STAINLESS STEEL GRATE
NOTE: THIS CONNECTION MUST BE MADE
AT THE FACTORY
ZURN MODEL #Z-Z882 HIGH DENSITY
POLYETHYLENE WITH STEEL FRAME
TRENCH DRAIN SYSTEM
END CAP
PLAN VIEW
ELEVATION
1 TRENCH DRAIN WITH CATCH BASIN DETAIL
SCALE: NTS
FINISH FLOOR = 100'-0"
I.E. = 99'-11 1/2"
FINISH
FLOOR
1'-0" 12"
P e t t i t t Y a s t e
S t r a u b
200S
LAWSON,C MICHIGAN
UITE
48017-1311
F A X248-658-7781
248-658-7777 P H O N E
C850 NORTH ROOKS ROAD
MUSKEGON CORRECTIONAL
FACILITY
GREENHOUSE
M A
T R
I X
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P
L A
C H
R
A
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
MP4
BELOW 1ST FLOOR PLAN -
MECHANICAL/PLUMBING NEW
N BELOW 1ST FLOOR PLAN - MECHANICAL/PLUMBING NEW
SCALE: 1/4" = 1'-0"
0 1 5 10
UH-1
EF-2
L-1
UH-2
HAF-1 HAF-2
HAF-3 HAF-4
SC SC
STM
SC
STM
T
UH-1
T
UH-2
1" CW, 1" SC, &
1-1/2" STM DN
HB-1 DWH-1SK-12" V DN
SC
STM
SC
SC
ST
M
ST
M
1/2" HW, 2"
V, & 3/4" CW
EF-1M
PRV-1
1"
1"
3/4"
3/4"
2"
2"
1-1/4" 1-1/4" 1-1/4"
3 3
8GREENHOUSE
CONTROL PANEL
3/4"
1"
3/4"
1-1/4"
ST
M
2" V, 3" V
THRU WALL
AND DN
L-2
M
L-44
L-3 M
M
1/2" HW, 2"
V, & 1/2" CW
RV-1
(ON ROOF)
M M
9 9
10M
WH-1
1 STEAM COIL PIPING DETAIL
SCALE: NTS
FT
STEAM
COILVACUUM
BREAKER
STM
SC 6"
MI
N.
1/4"/FT TO
CONDENSATE
OUTLET.
PITCH COIL
SCALE POCKET
FLOAT & THERMOSTATIC STEAM TRAP
SHUTOFF VALVE (TYP.)
THERMOSTATIC AIR VENT
UNION (TYP.)
2-WAY, 2- POSITION CONTROL VALVE
STRAINER (TYP.)
DWH-1
2 DOMESTIC WATER HEATER DETAIL
SCALE: NTS
SHUT-OFF VALVE (TYP.)
1/2" CW
1/2" CW
DIELECTRIC UNION
(TYP.)
1/2" HW UP TO SK-1
1/2" HW
1-1/4" STM
3/4" SC
3 STEAM PRESSURE REDUCING VALVE DETAIL - NEW
SCALE: NTS
PRV-1
P
P
2" V THRU
SIDEWALL
STRAINER
PRESSURE
GAUGE (TYP.)
REDUCER (TYP.)
PRESSURE
RELIEF VALVE
1-1/2" STM
2" STM (10 PSI)
STEAM PRV NOTES:
1. ALLOW AT LEAST 10 PIPE DIAMETERS OF
STRAIGHT PIPE.
2. ALL PIPING VALVING ETC. ON HIGH PRESSURE
SIDE OF PRV'S SHALL BE WELDED OR FLANGED.
3. ALL ACCESSORY PIPING ON HIGH PRESSURE
SIDE OF PRV'S SHALL BE SCREWED AND BACK
WELDED.
4. PRV-1: 322# FOR INLET PRESSURE OF 40 PSI
AND OUTLET PRESSURE OF 10 PSI, SELF
OPERATED.
1-1/2" STM
N.C. SHUTOFF
VALVE (TYP.)
GENERAL MECHANICAL/PLUMBING NOTES
1. INSTALL NEW STEAM PIPING, VALVES, FITTINGS, AND ALL ASSOCIATED ACCESSORIES IN THE LOCATION
SHOWN.
2. INSTALL NEW STEAM CONDENSATE PIPING, VALVES, FITTINGS, AND ALL ASSOCIATED ACCESSORIES IN
THE LOCATION SHOWN.
3. INSTALL NEW DOMESTIC COLD WATER PIPING, DOMESTIC HOT WATER PIPING, VALVES, FITTINGS, AND
ALL ASSOCIATED ACCESSORIES IN THE LOCATION SHOWN.
4. INSTALL NEW VENT PIPING AND ALL ASSOCIATED ACCESSORIES IN THE LOCATION SHOWN.
MECHANICAL/PLUMBING KEY NOTES
INSTALL NEW WALL MOUNTED EXHAUST FANS, CONTROLS, CONTROL WIRING, AND ALL
ASSOCIATED ACCESSORIES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.
CONNECT NEW EXHAUST FAN TO NEW GREENHOUSE CONTROL PANEL.
INSTALL NEW STEAM UNIT HEATER, THERMOSTAT, CONTROLS, CONTROL WIRING, STEAM
PIPING, CONDENSATE PIPING, VALVES, FITTINGS, AND ALL ASSOCIATED ACCESSORIES
PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. CONNECT NEW UNIT HEATER
TO NEW GREENHOUSE CONTROL PANEL.
INSTALL NEW RE-CIRCULATION FANS, CONTROLS, CONTROL WIRING, AND ALL
ASSOCIATED ACCESSORIES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.
CONNECT NEW RE-CIRCULATION FANS TO NEW GREENHOUSE CONTROL PANEL.
INSTALL NEW LOUVER, DAMPER, DAMPER ACTUATOR, CONTROLS, CONTROL WIRING, AND
ALL ASSOCIATED ACCESSORIES PER THE MANUFACTURER'S INSTALLATION
INSTRUCTIONS. CONNECT NEW DAMPER ACTUATORS TO NEW GREENHOUSE CONTROL
PANEL.
INSTALL NEW INSTANTANEOUS DOMESTIC WATER HEATER, CONTROLS, PIPING, VALVES,
FITTINGS, AND ALL ASSOCIATED ACCESSORIES PER THE MANUFACTURER'S INSTALLATION
INSTRUCTIONS.
INSTALL NEW HOSE BIB, PIPING, VALVES, FITTINGS, AND ALL ASSOCIATED ACCESSORIES
PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.
INSTALL FLOOR MOUNTED SINK, FAUCET, PIPING, VALVES, FITTINGS, AND ALL
ASSOCIATED ACCESSORIES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.
INSTALL NEW GREENHOUSE CONTROL PANEL, CONTROLS, CONTROL WIRING, AND ALL
ASSOCIATED ACCESSORIES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.
COORDINATE FINAL INSTALLATION LOCATION WITH OWNER. CONNECT ALL GREENHOUSE
CONTROL PANEL TEMPERATURE ALARMS TO THE FACILITY'S STARNET 2.0 SYSTEM.
CONNECT TO SECURITY IT RACK WITH PURPLE CAT-6 CABLES(S) AS REQUIRED TO
CONNECT TO STARNET 2.0 SYSTEM. CONTRACTOR TO HIRE AND COORDINATE
CONNECTION TO SECURITY IT RACK WITH BRETT EMERSON FROM COMMTECH DESIGN
(PHONE 616-446-4545).
INSTALL NEW ROOF MOUNTED RIDGE VENT, NEW ACTUATOR(S), CONTROLS, CONTROL
WIRING, AND ALL ASSOCIATED ACCESSORIES PER THE MANUFACTURER'S INSTALLATION
INSTRUCTIONS. CONNECT NEW DAMPER ACTUATORS TO NEW GREENHOUSE CONTROL
PANEL.
EQUIPMENT PROVIDED BY GREENHOUSE MANUFACTURER.
INSTALL NEW WALL HYDRANT, PIPING, VALVES, FITTINGS, AND ALL ASSOCIATED
ACCESSORIES PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.
INSTALL NEW DOMESTIC WATER METER AND ALL ASSOCIATED ACCESSORIES IN THE
LOCATION SHOWN. CONTRACTOR TO COORDINATE WITH WITH DOMESTIC WATER
SERVICE PROVIDER FOR THE INSTALLATION OF NEW DOMESTIC WATER METER.
P e t t i t t Y a s t e
S t r a u b
200S
LAWSON,C MICHIGAN
UITE
48017-1311
F A X248-658-7781
248-658-7777 P H O N E
C850 NORTH ROOKS ROAD
MUSKEGON CORRECTIONAL
FACILITY
GREENHOUSE
M A
T R
I X
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P
L A
C H
R
A
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
MP5
1ST FLOOR PLAN -
MECHANICAL/PLUMBING NEW
N 1ST FLOOR PLAN - MECHANICAL/PLUMBING NEW
SCALE: 1/4" = 1'-0"
0 1 5 10
GREENHOUSE MANUFACTURER PROVIDEDMECHANICAL CONTRACTOR PROVIDED
P e t t i t t Y a s t e
S t r a u b
200S
LAWSON,C MICHIGAN
UITE
48017-1311
F A X248-658-7781
248-658-7777 P H O N E
C850 NORTH ROOKS ROAD
MUSKEGON CORRECTIONAL
FACILITY
GREENHOUSE
M A
T R
I X
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P
L A
C H
R
A
D
IR
E C
T O
R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
MP6
MECHANICAL/PLUMBING
SCHEDULES
| Sheets and Views |
| MP1-2339900-MP1 |
| MP2-2339900-MP2 |
| MP3-2339900-MP3 |
| MP4-2339900-MP4 |
| MP5-2339900-MP5 |
| MP6-2339900-MP6 |
File details come from the government source that posted it. Updated .