23-17_Drawings.pdf
PDF 11 MB Posted
- Attached to
- Specification No. 23-17 (C51654), Abandoned Pipes and Conduits Removal, Sacramento River, Hood, CA
- Solicitation number
- 0000030248
- Issued by
- Sacramento County, Hayward City, California
About this file
The document is a set of drawings related to Specification No. 23-17 (C51654), a state and local contract opportunity issued by the State of California for the removal of an abandoned fish screen testing facility from the levee site located on the Sacramento River in Hood, CA. The project will restore the levee to its original contour and grade, with an estimated cost range of $750,000 to $835,000. The contract is open to interested parties in Sacramento County and the City of Hayward.
The pricing terms, set-asides, funding requirements, and other salient details are not included in the provided document. Interested parties are advised to review the full contract opportunity details, including any addenda or supporting exhibits, to understand the complete scope of work, bidding requirements, and contract terms.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G-10101
A
B
C
D
SPEC. NO.
1 2 3 4 5 6 7
2 3 4 5 6 71
SHEET NO. REVISION DRAWING NO.
DATE:
REV. SUB. APP.DESCRIPTION
CALIFORNIA NATURAL RESOURCES AGENCY
DIVISION OF ENGINEERING
STATE OF CALIFORNIA
DEPARTMENT OF WATER RESOURCES
APPROVED:
THINK SAFETY -
ACT SAFELY
STATE OF CALIFORNIA
DEPARTMENT OF WATER RESOURCES
DIVISION OF ENGINEERING
VICINITY MAP
CALIFORNIA NATURAL RESOURCES AGENCY
SPECIFICATION NO. 23-17
LOCATION MAP
SAN
FRANCISCO
LOS ANGELES
SAN DIEGO
EUREKA
PROJECT
AREA
ABANDONED PIPES AND CONDUITS REMOVAL
SACRAMENTO RIVER
SACRAMENTO
N
23-17
N
STATE PLAN OF FLOOD CONTROL FACILITIES
ACTING MANAGER, DIVISION OF ENGINEERING, REG. C.E. No. 51470
2020 L STREET SUITE 400
SACRAMENTO, CA 95811
T: (916) 414-5800
F: (916) 414-1557
LIST OF DRAWINGS
SHEET DRAWING DRAWING TITLE
01 G-101 COVER SHEET
02 G-102
NOTES, LEGEND, AND ABBREVIATIONS
C-101 SITE ACCESS
C-102 STAGING AND LAYDOWN AREAS
C-103
DEMOLITION PLAN
C-106
C-107
C-108
C-109
C-110
FILL SECTIONS 1 OF 2C-111
FILL SECTIONS 2 OF 2
C-104
SITE PLAN
EXCAVATION PLANC-105
FILL PLAN
EXCAVATION PLAN AND PROFILE
EXCAVATION SECTIONS 1 OF 2
EXCAVATION SECTIONS 2 OF 2
C-112
FILL PLAN AND PROFILE
03 G-103 EROSION CONTROL FABRIC DETAILS
SITE DESIGNATION
LOCAL AGENCY WATERWAY
MA0009 SACRAMENTO RIVERU01 LM 17.59
UNIT CODE LEVEE MILE
04 V-101 SURVEY CONTROL
DocuSign Envelope ID: 71C64730-748C-4CDE-8F79-8E1289AEFF6B
6/30/2023
O. RAGABO
N. PLATH
R. MILLET
1. GENERAL NOTES ARE APPLICABLE TO ALL WORK, UNLESS NOTED OTHERWISE.
2. ACCESS TO THE PROJECT IS LIMITED TO THE ACCESS POINTS SHOWN ON THE DRAWINGS.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR EVALUATING THE CAPACITY OF ALL BRIDGES, CULVERTS AND
BURIED PIPELINES TO BE CROSSED BY HAUL VEHICLES, INCLUDING OBTAINING PERMITS BY LOCAL AGENCIES
PRIOR TO CONSTRUCTION.
4. THE HORIZONTAL DATUM IS THE NORTH AMERICAN DATUM OF 1983 (NSRS 2007) EPOCH 2017.95. THE DATA IS
PROJECTED TO THE CALIFORNIA STATE PLANE COORDINATE SYSTEM ZONE II. UNITS ARE U.S. SURVEY FEET.
5. THE VERTICAL DATUM IS THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88) DERIVED FROM NAD83
ELLIPSOID HEIGHTS WITH THE GEOID 12B MODEL APPLIED. UNITS ARE U.S. SURVEY FEET.
6. TOPOGRAPHY SHOWN IS BASED ON LIDAR COLLECTED IN 2017 BY WOOLPERT. BATHYMETRIC DATA SHOWN IS
BASED ON DATA COLLECTED IN 2011 FROM THE CENTRAL VALLEY FLOOD PROTECTION AND DELINEATION
PROGRAM.
7. STAGING AND LAYDOWN AREAS SHOWN ARE APPROXIMATE. CONTRACTOR SHALL SUBMIT A SURVEY OF THE
PROPOSED AREA AND PROVIDE THIS SURVEY TO THE ENGINEER'S REPRESENTATIVE FOR FAVORABLE
REVIEW PRIOR TO CONSTRUCTION PER SPECIFICATION SECTION 01720 SURVEYING (CONSTRUCTION LAYOUT, TOPOGRAPHY, MEASUREMENT FOR PAYMENT).
8. CONTRACTOR SHALL COORDINATE SITE ENVIRONMENTAL CLEARANCES WITH DWR PRIOR TO MOBILIZATION.
9. TYPICAL SECTIONS DEFINE GEOMETRY AND MATERIAL TO BE UTILIZED THROUGH THE LIMITS OF REPAIR
UNLESS OTHERWISE NOTED. LATERAL EDGES OF REPAIR SHALL CONFORM TO EXISTING GRADE.
10. THE LOCATIONS OF EXISTING UTILITIES, IF ANY, ARE APPROXIMATE AND HAVE NOT BEEN INDEPENDENTLY
VERIFIED BY THE ENGINEER'S REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION
OF ALL UTILITIES WITHIN THE CONSTRUCTION ZONE, ALONG THE CONSTRUCTION ACCESS ROUTE AND IN THE
STAGING AREAS BEFORE COMMENCING WORK. THE CONTRACTOR SHALL PROTECT ALL UTILITIES, AND SHALL
BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH ARE CAUSED BY THE CONTRACTOR'S FAILURE
TO LOCATE AND PRESERVE ANY AND ALL UTILITIES. CONTRACTOR SHALL NOTIFY USA A MINIMUM OF TWO
DAYS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL OBTAIN ALL PERMITS NECESSARY TO WORK AROUND
EXISTING UTILITIES.
11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED TO EXISTING FACILITIES
TO PRE-CONSTRUCTION CONDITIONS OR BETTER. DAMAGED ROADS, CURBS, GUARDRAILS, SIGNS, FENCES, UTILITIES, FLOOD CONTROL STRUCTURES, AND STAGING AND LAYDOWN AREAS WITHIN OR OUTSIDE OF THE
LIMITS OF WORK SHALL BE REPLACED OR REPAIRED TO APPLICABLE COUNTY AND/OR CALTRANS STANDARDS
AT THE CONTRACTOR'S EXPENSE.
12. EXISTING ROADWAYS INCLUDING HIGHWAY 160 SHALL BE KEPT CLEAR OF MUD AND DEBRIS AT ALL TIMES.
13. DRAWING SCALES DEPICTED ARE BASED ON DWR DIVISION OF ENGINEERING CAD STANDARDS 7.2.3. SET
PLOTTING AREA FOR 22"x34" (D SIZE). CONFIRM SCALE FOR DRAWINGS PLOTTED AT ALL OTHER DIMENSIONS.
14. WATER LEVEL INDICATED ON THE DRAWINGS MAY BE SUBJECT TO SEASONAL FLUCTUATION AND TIDAL
INFLUENCE. WATER LEVEL AT TIME OF CONSTRUCTION IS BASED ON GAGE DATA.
15. THE CONTRACTOR'S POST-EXCAVATION SURVEY (REF. SECTION 01720-1.03A.2) SHALL BE FAVORABLY
REVIEWED BY THE ENGINEER'S REPRESENTATIVE PRIOR TO PLACEMENT OF FILL MATERIAL.
16. THE REFERENCE CENTERLINE PROVIDES SURVEY CONTROL FOR EXCAVATION AND LEVEE FILL PLACEMENT.
17. AGRICULTURAL SOIL, SEEDING, AND EROSION CONTROL FABRIC SHALL BE APPLIED ON THE LEVEE SLOPE AS
SPECIFIED ON DRAWINGS G-103 AND C-111.
18. ABANDONED PIPES AND CONDUITS WITHIN THE EXCAVATION LIMITS SHALL BE FULLY REMOVED. CHASE
ABANDONED PIPES AND CONDUITS THAT EXTEND BEYOND THE LIMITS OF EXCAVATION UP TO THE LIMITS OF
WORK. BACKFILL EXTENDED EXCAVATIONS WITH THE SAME PROCEDURES UTILIZED WITHIN THE EXCAVATION
LIMITS AS PRESCRIBED BY THE CONTRACT DOCUMENTS.
GENERAL NOTES: ABBREVIATIONS:
CAD COMPUTER AIDED DESIGN
CMP CORRUGATED METAL PIPE
D DEGREE OF CURVATURE
DWR DEPARTMENT OF WATER RESOURCES
E EASTING
ECF EROSION CONTROL FABRIC
EL ELEVATION
ER EDGE OF ROAD
FT FEET
H:V HORIZONTAL TO VERTICAL
HDPE HIGH DENSITY POLYETHYLENE
HL HINGE LINE
HOR HORIZONTAL
L LENGTH
LM LEVEE MILE
MA MAINTENANCE AREA
MAX MAXIMUM
MIN MINIMUM
N NORTHING
NAD83 NORTH AMERICAN DATUM OF 1983
NAVD88 NORTH AMERICAN VERTICAL DATUM OF 1988
NIC NOT IN CONTRACT
NO NUMBER
NSRS NATIONAL SPATIAL REFERENCE SYSTEM
NTS NOT TO SCALE
R RADIUS
RD ROAD
S SOUTH
SPEC SPECIFICATION
STA STATION
ST STREET
T TELEPHONE
TYP TYPICAL
U UNIT
U.S. UNITED STATES
USA UNDERGROUND SERVICE ALERT
VERT VERTICAL
AGGREGATE BASE RESURFACING
LEGEND:
TREE
CROSS SECTION LETTER
SHEET WHERE SHOWN
A1
C09-1
SOIL-FILLED ROCKFILL
OH OVERHEAD UTILITY LINE
SLOPE
GEOTEXTILE FABRIC
REFERENCE LINE
10+10
EXISTING MAJOR CONTOURS
EXISTING MINOR CONTOURS
LIMITS OF WORK
HIGH TIDE/LOW TIDE WATER LEVEL
EXISTING GRADE
LIMITS OF REPAIR/LIMITS OF EXCAVATION
TELEPHONE LINE
ELECTRICAL LINE
CONCRETE
LEVEE FILL
E E
POLEP
ANOMALOUS AREA
SPEC. NO.
1 2 3 4 5 6 7
2 3 4 5 6 71
SHEET NO. REVISION DRAWING NO.
CALIFORNIA NATURAL RESOURCES AGENCY
DIVISION OF ENGINEERING
STATE OF CALIFORNIA
DEPARTMENT OF WATER RESOURCES
THINK SAFETY -
ACT SAFELY
SUBMITTED:
DESIGNED:
DRAWN: REVIEWED:
DATE:
DATE:
REV. SUB. APP.DESCRIPTION
APPROVED:
APPROVAL RECOMMENDED:
MANAGER, GEOTECHNICAL SERVICES BRANCH, REG. C.E. No. 52754
MANAGER, GEOTECHNICAL ENGINEERING SEC., REG. C.E. No. 65001
REG. C.E. No. 42663
ABANDONED PIPES
AND CONDUITS REMOVAL
SACRAMENTO RIVER
23-17
CHECKED:
LOREN A. MURRAY
2020 L STREET SUITE 400
SACRAMENTO, CA 95811
T: (916) 414-5800
F: (916) 414-1557
A
B
C
D E
T TT
ACCESS GATE
EDGE OF ROAD
LIMITS OF LEACH FIELD
TO BE DEMOLISHED
TEMPORARY FENCING
X FENCE
POTENTIAL STAGING AND LAYDOWN AREA
SURVEY CONTROL POINT
CP #123
AGRICULTURAL SOIL
EROSION CONTROL FABRIC
DWR OUTER PROPERTY BOUNDARY
DWR INNER PROPERTY BOUNDARY
NOTES, LEGEND, AND
ABBREVIATIONS
G-10202
DocuSign Envelope ID: 71C64730-748C-4CDE-8F79-8E1289AEFF6B
6/29/2023
TOP OF SLOPE
WATERWAY FLOW DIRECTION
DOWNSTREAM ECF RUN WIDTH
D O
W N
S
LO
P E
2' MIN
SIDE
OVERLAP
ECF KEY TRENCHED ON
THREE SIDES
KEY TRENCH AT
LIMITS OF REPAIR
(1'-0" x 1'-0" MINIMUM)
UPSTREAM ECF RUN WIDTH
5' -0
M
A X
T Y
P
IC
A L
BOTTOM OF SLOPE
BURLAP BAG
EROSION
CONTROL
FABRIC
BACKFILL WITH
NATIVE SOIL
KEY TRENCH 12" STAKES
AT 4' O.C.
EXISTING
GRADE
LEVEE FILL
M
IN
12" MIN
6"
8" M
IN
O. RAGABO
O. RAGABO
N. PLATH
R. MILLET
EROSION CONTROL FABRIC
DETAILS
TYPICAL EROSION CONTROL FABRIC INSTALLATION - PLAN
SCALE: 1" = 2'A1
TYPICAL KEY TRENCH - DETAIL
SCALE: NTS A5
AGRICULTURAL
SOIL
SPEC. NO.
1 2 3 4 5 6 7
2 3 4 5 6 71
SHEET NO. REVISION DRAWING NO.
CALIFORNIA NATURAL RESOURCES AGENCY
DIVISION OF ENGINEERING
STATE OF CALIFORNIA
DEPARTMENT OF WATER RESOURCES
THINK SAFETY -
ACT SAFELY
SUBMITTED:
DESIGNED:
DRAWN: REVIEWED:
DATE:
DATE:
REV. SUB. APP.DESCRIPTION
APPROVED:
APPROVAL RECOMMENDED:
MANAGER, GEOTECHNICAL SERVICES BRANCH, REG. C.E. No. 52754
MANAGER, GEOTECHNICAL ENGINEERING SEC., REG. C.E. No. 65001
REG. C.E. No. 42663
ABANDONED PIPES
AND CONDUITS REMOVAL
SACRAMENTO RIVER
23-17
CHECKED:
LOREN A. MURRAY
2020 L STREET SUITE 400
SACRAMENTO, CA 95811
T: (916) 414-5800
F: (916) 414-1557
A
B
C
D
G-10303
DocuSign Envelope ID: 71C64730-748C-4CDE-8F79-8E1289AEFF6B
6/29/2023
X
X
X
X
X
X
X
X
X
X
X X
O H
O H
P
-20
-15
-10
-5
-15
-10
-5
CP #7006
CP #6004
CP #7004
N10° 14' 40.24"W 192.80' (TIE)
N64° 59' 44.52"E 63.21' (TIE)
SCALE: 1" = 10'
SURVEY CONTROL
100510
SCALE: 1"=10'
SPEC. NO.
1 2 3 4 5 6 7
2 3 4 5 6 71
SHEET NO. REVISION DRAWING NO.
CALIFORNIA NATURAL RESOURCES AGENCY
DIVISION OF ENGINEERING
STATE OF CALIFORNIA
DEPARTMENT OF WATER RESOURCES
THINK SAFETY -
ACT SAFELY
SUBMITTED:
DESIGNED:
DRAWN: REVIEWED:
DATE:
DATE:
REV. SUB. APP.DESCRIPTION
APPROVED:
APPROVAL RECOMMENDED:
MANAGER, GEOTECHNICAL SERVICES BRANCH, REG. C.E. No. 52754
MANAGER, GEOTECHNICAL ENGINEERING SEC., REG. C.E. No. 65001
REG. C.E. No. 42663
ABANDONED PIPES
AND CONDUITS REMOVAL
SACRAMENTO RIVER
23-17
CHECKED:
LOREN A. MURRAY
2020 L STREET SUITE 400
SACRAMENTO, CA 95811
T: (916) 414-5800
F: (916) 414-1557
A
B
C
D
O. RAGABO
O. RAGABO
N. PLATH
R. MILLET
SURVEY CONTROL
N
SURVEY CONTROL TABLE
POINT # NORTHING EASTING ELEVATION DESCRIPTION
6004 1896039.82 6699256.80 26.54
SET CONTROL MON 50D & SHINER IN
LINOLEUM
7004 1895850.09 6699291.09 27.84
FND CONTROL MON 80D SPIKE DWR WSR
7004 DWR CNTRL
7006 1896066.54 6699314.09 25.04
FND CONTROL MON 1 IN IP DWR AP 7006 DWR
COR
BASIS OF BEARING AND COORDINATES:
COORDINATES, BEARINGS AND DISTANCES ARE BASED ON THE NATIONAL GEODETIC SURVEY (NGS)
CONTINUOUS OPERATING REFERENCE STATIONS (CORS) NORTH AMERICAN DATUM OF 1983 (NAD83 (2011))
CC83 ZONE 2 US SURVEY FEET.
VERTICAL COORDINATE DATUM:
THE ELEVATIONS ESTABLISHED IN THIS SURVEY ARE BASED ON THE NORTH AMERICAN VERTICAL DATUM OF
1988 (NAVD88) USING THE 2010 EPOCH ELLIPSOID HEIGHTS WITH GEOID 12B APPLIED.
SURVEY CONTROL ACCURACY:
DWR ABSOLUTE SURVEY CONTROL HORIZONTAL ACCURACY AT 95% CONFIDENCE LEVEL: 0.035 US FEET
DWR ABSOLUTE SURVEY CONTROL VERTICAL ACCURACY AT 95% CONFIDENCE LEVEL: 0.070 US FEET
REFERENCE: TRIMBLE BUSINESS CENTER NETWORK ADJUSTMENT REPORT
NOTE:
SEE DEPARTMENT OF WATER RESOURCES GEO-21-0025 SURVEY CONTROL REPORT FOR ADDITIONAL
PROJECT INFORMATION.
MONUMENT PRESERVATION:
BPC 8771 (a)-(f) AND 8773.3
THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH THE CALIFORNIA BUSINESS AND
PROFESSIONS CODE 8771 TO ENSURE THAT ALL EXISTING SURVEY CONTROL AND MONUMENTS WITHIN
THE BOUNDS OF THE PERMITTED CONSTRUCTION ARE PROTECTED. PRIOR TO CONSTRUCTION, THE
CONTRACTOR SHALL DESIGNATE A LICENSED LAND SURVEYOR OR A PROFESSIONAL CIVIL ENGINEER
AUTHORIZED TO PERFORM LAND SURVEYING IN THE STATE OF CALIFORNIA AS THE PERSON
RESPONSIBLE FOR COMPLIANCE. ANY EXISTING SURVEY CONTROL OR MONUMENT SHOWN OR NOT
SHOWN HEREIN MUST BE PRESERVED, REFERENCED, OR REPLACED, AND THE CONTRACTOR IS
RESPONSIBLE FOR FILING OF ANY REQUIRED CORNER RECORD(S) OR RECORD(S) OF SURVEY. V-10104
DocuSign Envelope ID: 71C64730-748C-4CDE-8F79-8E1289AEFF6B
6/29/2023
N. PLATH
R. MILLET
SPEC. NO.
1 2 3 4 5 6 7
2 3 4 5 6 71
SHEET NO. REVISION DRAWING NO.
CALIFORNIA NATURAL RESOURCES AGENCY
DIVISION OF ENGINEERING
STATE OF CALIFORNIA
DEPARTMENT OF WATER RESOURCES
THINK SAFETY -
ACT SAFELY
SUBMITTED:
DESIGNED:
DRAWN: REVIEWED:
DATE:
DATE:
REV. SUB. APP.DESCRIPTION
APPROVED:
APPROVAL RECOMMENDED:
MANAGER, GEOTECHNICAL SERVICES BRANCH, REG. C.E. No. 52754
MANAGER, GEOTECHNICAL ENGINEERING SEC., REG. C.E. No. 65001
REG. C.E. No. 42663
ABANDONED PIPES
AND CONDUITS REMOVAL
SACRAMENTO RIVER
23-17
CHECKED:
LOREN A. MURRAY
2020 L STREET SUITE 400
SACRAMENTO, CA 95811
T: (916) 414-5800
F: (916) 414-1557
A
B
C
D
NOTES:
1. SEE DRAWING G-101 FOR PROJECT SITE
VICINITY MAP.
SITE ACCESS
N
C-10105
DocuSign Envelope ID: 71C64730-748C-4CDE-8F79-8E1289AEFF6B
6/29/2023
NOTES:
1. ACCESS TO THE WORK AREA IS PROHIBITED
BY A CHAIN LINK FENCE. CONTRACTOR TO
COORDINATE WITH DWR FOR SITE ACCESS
USING EXISTING GATE ON RIVER ROAD.
2. THE STAGING AND LAYDOWN AREAS SHOWN
ARE APPROXIMATE. SEE NOTE 7 ON DRAWING
G-102.
3. STAGING AND LAYDOWN AREA B MAY BE
USED AFTER EXCAVATION AND BACKFILL OF
THE LEACH FIELD.
O. RAGABO
O. RAGABO
N. PLATH
R. MILLET
SPEC. NO.
1 2 3 4 5 6 7
2 3 4 5 6 71
SHEET NO. REVISION DRAWING NO.
CALIFORNIA NATURAL RESOURCES AGENCY
DIVISION OF ENGINEERING
STATE OF CALIFORNIA
DEPARTMENT OF WATER RESOURCES
THINK SAFETY -
ACT SAFELY
SUBMITTED:
DESIGNED:
DRAWN: REVIEWED:
DATE:
DATE:
REV. SUB. APP.DESCRIPTION
APPROVED:
APPROVAL RECOMMENDED:
MANAGER, GEOTECHNICAL SERVICES BRANCH, REG. C.E. No. 52754
MANAGER, GEOTECHNICAL ENGINEERING SEC., REG. C.E. No. 65001
REG. C.E. No. 42663
ABANDONED PIPES
AND CONDUITS REMOVAL
SACRAMENTO RIVER
23-17
CHECKED:
LOREN A. MURRAY
2020 L STREET SUITE 400
SACRAMENTO, CA 95811
T: (916) 414-5800
F: (916) 414-1557
A
B
C
D
POTENTIAL STAGING
AND LAYDOWN AREA A
POTENTIAL STAGING
AND LAYDOWN AREA B
(SEE NOTE 3)
STAGING AND LAYDOWN
AREAS
N
C-10206
DocuSign Envelope ID: 71C64730-748C-4CDE-8F79-8E1289AEFF6B
6/29/2023
N: 1896066.67 E: 6699312.06
N: 1895865.88 E: 6699281.29
N: 1896065.16 E: 6699205.96
X
X
X
X
X
X
X
X
X
X
X
X X
N: 1895960.93 E: 6699360.19
O H
O H
N: 1895911.10 E: 6699172.86
N: 1895945.75 E: 6699169.46
N: 1895880.57 E: 6699296.58
N: 1896065.32 E: 6699241.64
11+00
12+00
10+25
12+25
P
-20
-15
-10
-5
-15
-10
-5
L=19 .90', R=50.00'
D=22°47'58"
L=16.55', R=50.00' D=18°57'42"
N39° 04' 28.16"W
44.81'
N2° 41' 12.10"E 54.19'
N16° 16' 30.01"W
64.55'
START CURVE
STATION = 10+69.83
NORTHING: 1895915.38
EASTING: 6699268.32
END CURVE
STATION = 11+70.82
NORTHING: 1896011.20
EASTING: 6699239.10
START CURVE
STATION = 11+54.27
NORTHING: 1895994.84
EASTING: 6699241.05
END CURVE
STATION = 10+89.72
NORTHING: 1895932.88
EASTING: 6699259.14
SCALE: 1" = 10'
SITE LOCATION
100510
SCALE: 1"=10'
SPEC. NO.
1 2 3 4 5 6 7
2 3 4 5 6 71
SHEET NO. REVISION DRAWING NO.
CALIFORNIA NATURAL RESOURCES AGENCY
DIVISION OF ENGINEERING
STATE OF CALIFORNIA
DEPARTMENT OF WATER RESOURCES
THINK SAFETY -
ACT SAFELY
SUBMITTED:
DESIGNED:
DRAWN: REVIEWED:
DATE:
DATE:
REV. SUB. APP.DESCRIPTION
APPROVED:
APPROVAL RECOMMENDED:
MANAGER, GEOTECHNICAL SERVICES BRANCH, REG. C.E. No. 52754
MANAGER, GEOTECHNICAL ENGINEERING SEC., REG. C.E. No. 65001
REG. C.E. No. 42663
ABANDONED PIPES
AND CONDUITS REMOVAL
SACRAMENTO RIVER
23-17
CHECKED:
LOREN A. MURRAY
2020 L STREET SUITE 400
SACRAMENTO, CA 95811
T: (916) 414-5800
F: (916) 414-1557
A
B
C
D
METAL
CATWALK
9" PILE (TYP)
LANDSIDE
(SACRAMENTO RIVER)
WATERSIDE
O. RAGABO
O. RAGABO
N. PLATH
R. MILLET
FENCE
LIMITS OF WORK
SERVICE
PANEL
RETAINING WALL
(SEE NOTE 2)4" STEEL PIPE
ACCESS GATE
(SEE NOTE 3)
NOTES:
1. TREES IDENTIFIED ON THE
DRAWINGS SHALL NOT BE
REMOVED OR TRIMMED UNLESS
OTHERWISE SPECIFIED.
2. CONTRACTOR SHALL NOT
DAMAGE THE SPECIFIED TREES,
RETAINING WALL, SUBSTATION,
AND PUMPSTATION OR ANY OF ITS
ASSOCIATED FEATURES
INCLUDING UTILITIES, PIPES, AND
WATER QUALITY GAGE STATION.
3. CONTRACTOR SHALL USE THE
ACCESS GATE ON RIVER ROAD
(CA-160) FOR SITE INGRESS AND
EGRESS.
4. INSTALL TEMPORARY FENCING
WHERE SHOWN ALONG THE
LIMITS OF WORK.
5. BACKFILL CAVITIES CREATED BY
TREE STUMP REMOVAL PER
SPECIFICATION SECTION 02300
EARTHWORK.
R
IVER
R O
AD
ER
ER
PUMPSTATION
BRIDGE
SUBSTATION
(SEE NOTE 2)
REFERENCE LINE
TEMPORARY
FENCING
(SEE NOTE 4)
POTENTIAL STAGING
AND LAYDOWN AREA A
POTENTIAL STAGING
AND LAYDOWN AREA B
REMOVE BLACK
LOCUST TREE STUMPS
(SEE NOTE 4)
36" DISCHARGE CMP
TREES
(SEE NOTE 2)
TREE
(SEE NOTE 2)
GRAVEL SURFACING
RAILROAD TIES
END
TEMPORARY
FENCING
DWR OUTER
PROPERTY
BOUNDARY
DWR INNER
PROPERTY
BOUNDARY
SITE PLAN
N
C-10307
DocuSign Envelope ID: 71C64730-748C-4CDE-8F79-8E1289AEFF6B
6/29/2023
X
X
X
X
X
X
X
X
X
X X
O H
O H
11+00
12+00
10+25
12+25
P
-20
-15
-10
-5
-15
-10
-5
SCALE: 1" = 10'
DEMOLITION PLAN
100510
SCALE: 1"=10'
O. RAGABO
O. RAGABO
N. PLATH
R. MILLET
SPEC. NO.
1 2 3 4 5 6 7
2 3 4 5 6 71
SHEET NO. REVISION DRAWING NO.
CALIFORNIA NATURAL RESOURCES AGENCY
DIVISION OF ENGINEERING
STATE OF CALIFORNIA
DEPARTMENT OF WATER RESOURCES
THINK SAFETY -
ACT SAFELY
SUBMITTED:
DESIGNED:
DRAWN: REVIEWED:
DATE:
DATE:
REV. SUB. APP.DESCRIPTION
APPROVED:
APPROVAL RECOMMENDED:
MANAGER, GEOTECHNICAL SERVICES BRANCH, REG. C.E. No. 52754
MANAGER, GEOTECHNICAL ENGINEERING SEC., REG. C.E. No. 65001
REG. C.E. No. 42663
ABANDONED PIPES
AND CONDUITS REMOVAL
SACRAMENTO RIVER
23-17
CHECKED:
LOREN A. MURRAY
2020 L STREET SUITE 400
SACRAMENTO, CA 95811
T: (916) 414-5800
F: (916) 414-1557
A
B
C
D
NOTES:
1. CONTRACTOR TO COORDINATE
WITH ALL APPLICABLE UTILITY
AGENCIES BEFORE REMOVAL OF
LINES OR SERVICE PANELS. THE
SERVICE PANEL IS SUSPECTED TO
BE CONNECTED TO AN ACTIVE
BURIED TELEPHONE LINE.
2. CONTRACTOR SHALL REMOVE ALL
PILES. IF PILE BREAKS AT OR
NEAR THE EXISTING SUBSTRATE
AND CANNOT BE REMOVED BY
OTHER METHODS, THE PILE SHALL
BE CUT AT LEAST 1' BELOW THE
MUDLINE. THE PILE DEPTHS ARE
UNKNOWN.
3. CONTRACTOR TO REMOVE AND
DISPOSE OF ABOVE GROUND 36"
DISCHARGE CMP AND 65' x 4'
METAL CATWALK. THE CATWALK
HAS AN ELECTRICAL SERVICE LINE
(SEE DRAWING C-105) COMING
FROM THE SUBSTATION.
4. CONTRACTOR TO RELOCATE
RAILROAD TIES TO THE STAGING
AREA PRIOR TO EXCAVATION.
RESTORE TO THE
PRE-CONSTRUCTION LOCATION
AFTER COMPLETING FINISHED
GRADE UNLESS DIRECTED
OTHERWISE BY THE ENGINEER'S
REPRESENTATIVE.
5. BACKFILL CAVITIES CREATED BY
TREE STUMP REMOVAL PER
SPECIFICATION SECTION 02300
EARTHWORK.
6. SEE DRAWING C-103 FOR
ADDITIONAL NOTES.
LIMITS OF
WORK
LANDSIDE
(SACRAMENTO RIVER)
WATERSIDE
REFERENCE LINE
R
IVER
R O
AD
FENCE
RETAINING WALL
PUMPSTATION
BRIDGE
SUBSTATION
REMOVE UTILITY LINES
AND SERVICE PANEL
(SEE NOTE 1)
10+25
ER
ER
ACCESS
GATE
TEMPORARY
FENCING
TREES
TREE
RAILROAD TIES
(SEE NOTE 4)
REMOVE BLACK
LOCUST TREE STUMPS
(SEE NOTE 5)
DEMOLITION PLAN
REMOVE 36"
DISCHARGE CMP
(SEE NOTE 3)
REMOVE METAL
CATWALK
(SEE NOTE 3)
REMOVE 9"
PILES (TYP)
(SEE NOTE 2)
N
C-10408
DocuSign Envelope ID: 71C64730-748C-4CDE-8F79-8E1289AEFF6B
6/29/2023
T
T
T T
T T
T T
X
X
X
X
X
X
X
X
X
X
X
X X
O H
O H
E E
E E
E E
E E E E
E
11+00
12+00
10+25
12+25
P
-15
-10
-5
-20
-15
-10
-5
N: 1896044.18 E: 6699271.47
N: 1895932.98 E: 6699335.24
N: 1895895.47 E: 6699292.77
N: 1895896.89 E: 6699261.59
N: 1895918.18 E: 6699249.33
N: 1895945.14 E: 6699237.20
N: 1896056.57 E: 6699235.62
N: 1895986.32 E: 6699302.10
SCALE: 1" = 10'
EXCAVATION PLAN
100510
SCALE: 1"=10'
O. RAGABO
O. RAGABO
N. PLATH
R. MILLET
SPEC. NO.
1 2 3 4 5 6 7
2 3 4 5 6 71
SHEET NO. REVISION DRAWING NO.
CALIFORNIA NATURAL RESOURCES AGENCY
DIVISION OF ENGINEERING
STATE OF CALIFORNIA
DEPARTMENT OF WATER RESOURCES
THINK SAFETY -
ACT SAFELY
SUBMITTED:
DESIGNED:
DRAWN: REVIEWED:
DATE:
DATE:
REV. SUB. APP.DESCRIPTION
APPROVED:
APPROVAL RECOMMENDED:
MANAGER, GEOTECHNICAL SERVICES BRANCH, REG. C.E. No. 52754
MANAGER, GEOTECHNICAL ENGINEERING SEC., REG. C.E. No. 65001
REG. C.E. No. 42663
ABANDONED PIPES
AND CONDUITS REMOVAL
SACRAMENTO RIVER
23-17
CHECKED:
LOREN A. MURRAY
2020 L STREET SUITE 400
SACRAMENTO, CA 95811
T: (916) 414-5800
F: (916) 414-1557
A
B
C
D C1
C-07
A1
C-08
A1
C-07
LIMITS OF
WORK
CUT SLOPE
1.5H:1V
LIMITS OF
EXCAVATION
EL. 23.5'
EL. 19.0'
EL. 23.0'
6.6%
CUT SLOPE
2.5H:1V
LANDSIDE
(SACRAMENTO RIVER)
WATERSIDE
REFERENCE
LIN
E
R
IVER
R O
AD
FENCE
NOTES:
PUMPSTATION
BRIDGE
1. EXCAVATION LOCATION, DEPTH,
AND GRADE ARE SUBJECT TO
MODIFICATION BASED ON FIELD
LOCATED STRUCTURES IN THE
ANOMALOUS AREAS.
2. UTILITY LOCATIONS SHOWN ARE
APPROXIMATE AND SHALL BE
FIELD VERIFIED BY THE
CONTRACTOR BY POTHOLING
PRIOR TO EXCAVATION.
3. ANOMALOUS AREAS WERE
LOCATED BASED ON
ELECTROMAGNETIC AND
GROUND PENETRATING RADAR
SURVEYS. SEE DOCUMENT 00300
INFORMATION AVAILABLE FOR
THE SURVEYS.
4. EXCAVATION OF SOIL SHALL BE
PERFORMED IN ACCORDANCE
WITH SPECIFICATION 02300
EARTHWORK.
5. REMOVAL OF NON-SOIL MATERIAL
SHALL BE PERFORMED IN
ACCORDANCE WITH
SPECIFICATION 02220 SELECTIVE
DEMOLITION.
6. CONFIRM LOCATION OF SEPTIC
TANK BY POTHOLING. THE SEPTIC
TANK AND ANY LIQUID CONTENTS
WITHIN IS ASSUMED TO BE
HAZARDOUS WASTE AND SHALL
BE REMOVED IN ACCORDANCE
WITH SPECIFICATION SECTION
13280 HAZARDOUS WASTE
RECOVERY AND DISPOSAL.
7. CONTRACTOR SHALL FULLY
REMOVE THE 4" STEEL PIPE.
CONTRACTOR TO MINIMIZE
GROUND DISTURBANCE DURING
REMOVAL AND BACKFILL PER
SPECIFICATION SECTION 02300
EARTHWORK..
8. CONTRACTOR TO VERIFY THAT
EXISTING ELECTRICAL LINE IS
DE-ENERGIZED PRIOR TO
EXCAVATION. IF ENERGIZED,
CONTACT SMUD CONSTRUCTION
SERVICES (T:916-732-5700, METER
ID 2517801).
9. THE PROPOSED SANITARY
SYSTEM DRAWING FROM
ORIGINAL PERMIT 9635A (1975) IS
PROVIDED IN DOCUMENT 00300
INFORMATION AVAILABLE.
10. CONTRACTOR SHALL FULLY
REMOVE THE PARTIALLY BURIED
HDPE PIPE.
11. SEE DRAWING C-103 FOR
ADDITIONAL NOTES.
4" STEEL PIPE
(SEE NOTE 7)
SUBSTATION
EL. 20.3'
CUT SLOPE
1H:1V
ER
ER
RETAINING WALL
ANOMALOUS
AREA
CONCRETE
RETURN BASIN
ELECTRICAL LINE
(SEE NOTE 8)
LIMITS OF
LEACH FIELD
24" STEEL PIPE
SEPTIC TANK
(SEE NOTE 6)
36" CMP
TELEPHONE
LINE
PROJECTED
HDPE PIPE
(SEE NOTE 10)
30" CMP
METAL
CATWALK
9" PILE (TYP)
ACCESS
GATE
36" DISCHARGE CMP
CUT SLOPE
1.5H:1V
CUT SLOPE 1H:1V
EL. 17.0'
TREE
TREE
TEMPORARY
FENCING
EXCAVATION PLAN
CUT SLOPE
1H:1V (TYP)
N
C-10509
DocuSign Envelope ID: 71C64730-748C-4CDE-8F79-8E1289AEFF6B
6/29/2023
E
LE
V A
T
IO
N
F T
E
LE
V A
T
IO
N
F T
STATION
10+50 11+00 11+50 12+00 12+25
EXISTING GRADE
EL. 23.0'
EL. 19.0'
EL. 23.5'
EXCAVATION LIMIT
6.6%
2.5
1.5 1.5
ANOMALOUS AREA
CONCRETE RETURN BASIN
PROJECTED 36" CMP PROJECTED 24" STEEL PIPESEPTIC TANK
EL. 23.0'
EL. 23.0'
EL. 19.0'
EL. 23.5'EL. 20.3'
S T
A
0+
.6
S T
A
0+
.9
S T
A
0+
.9
S T
A
0+
.0
S T
A
1+
.9
S T
A
2+
.7
S T
A
2+
.5
T
T
T T
T T
T T
X
X
X
X
X
X
X
X
X
X
X X
E E
E E
E E
E E E E
E
11+00
12+00
10+25
12+25
100510
100510
VERT SCALE: 1"=10'
HOR SCALE: 1"=10'
O. RAGABO
O. RAGABO
N. PLATH
R. MILLET
SPEC. NO.
1 2 3 4 5 6 7
2 3 4 5 6 71
SHEET NO. REVISION DRAWING NO.
CALIFORNIA NATURAL RESOURCES AGENCY
DIVISION OF ENGINEERING
STATE OF CALIFORNIA
DEPARTMENT OF WATER RESOURCES
THINK SAFETY -
ACT SAFELY
SUBMITTED:
DESIGNED:
DRAWN: REVIEWED:
DATE:
DATE:
REV. SUB. APP.DESCRIPTION
APPROVED:
APPROVAL RECOMMENDED:
MANAGER, GEOTECHNICAL SERVICES BRANCH, REG. C.E. No. 52754
MANAGER, GEOTECHNICAL ENGINEERING SEC., REG. C.E. No. 65001
REG. C.E. No. 42663
ABANDONED PIPES
AND CONDUITS REMOVAL
SACRAMENTO RIVER
23-17
CHECKED:
LOREN A. MURRAY
2020 L STREET SUITE 400
SACRAMENTO, CA 95811
T: (916) 414-5800
F: (916) 414-1557
A
B
C
D
NOTES:
1. SEE DRAWING C-105 FOR NOTES.
LIMITS OF
WORK
CUT SLOPE
1.5H:1V
LIMITS OF
EXCAVATION
EL. 23.5'
EL. 19.0'
EL. 23.0'
CUT SLOPE
2.5H:1V
LANDSIDE
(SACRAMENTO RIVER)
WATERSIDE
REFERENCE
LIN
E
R
IVER
R O
AD
FENCE
RETAINING WALL
PUMPSTATION
BRIDGE
4" STEEL PIPE
(SEE NOTE 7
DRAWING C-105)
SUBSTATION
EL. 20.3'
CUT SLOPE
1H:1V
ER
ER
ANOMALOUS
AREA (TYP)
CONCRETE
RETURN BASIN
ELECTRICAL LINE
(SEE NOTE 8
DRAWING C-105)
LIMITS OF
LEACH FIELD
24" STEEL PIPE
SEPTIC TANK
(SEE NOTE 6
DRAWING C-105)
36" CMP
TELEPHONE
LINE
PROJECTED
HDPE PIPE
(SEE NOTE 10
DRAWING C-105)
30" CMP
SCALE: 1" = 10'
EXCAVATION PLAN
SCALE: 1" = 10'
EXCAVATION PROFILE (ALONG REFERENCE LINE)
6.6%
100510
SCALE: 1"=10'
TEMPORARY
FENCING
METAL
CATWALK
9" PILE (TYP)
36" DISCHARGE CMP
CUT SLOPE
1.5H:1V
CUT SLOPE 1H:1V EL. 17.0'
EXCAVATION PLAN AND
PROFILE
N
C-10610
DocuSign Envelope ID: 71C64730-748C-4CDE-8F79-8E1289AEFF6B
6/29/2023
V A
T
IO
N
F T
E
LE
V A
T
IO
N
F T
DISTANCE (FT)
-25
-20
-15
-10
-5
-25
-20
-15
-10
-5
0 10 20 30 40 50 60 70 80 900-10-20-30-40-50-60
WATERSIDE LANDSIDE
R E
F E
R E
N C
E L
IN
E
EL. 19.0'EXCAVATION LIMIT
EXISTING GRADE
1.5
CONCRETE
RETURN BASIN
ANOMALOUS AREA
?1'
REMOVE PILES
(SEE NOTE 6)
HIGH TIDE
36" CMP
REMOVE METAL
CATWALK
1.5
3' EL. 17.0'
LOW
TIDE
E
LE
V A
T
IO
N
F T
E
LE
V A
T
IO
N
F T
DISTANCE (FT)
-25
-20
-15
-10
-5
-25
-20
-15
-10
-5
0 10 20 30 40 50 60 70 80 900-10-20-30-40-50-60
WATERSIDE LANDSIDE
R E
F E
R E
N C
E L
IN
E
EL. 23.0'EXCAVATION LIMIT
EXISTING GRADE
1.5 1.5
PROJECTED
LEACH LINE
(TYP)ANOMALOUS AREA
EL. 20.3'
SEPTIC TANK
EL. 23.0'
100510
100510
VERT SCALE: 1"=10'
HOR SCALE: 1"=10'
CROSS SECTION AT STA 11+00
C1
CROSS SECTION AT STA 10+60
A1
C-05 EXCAVATION PLAN
C-05 EXCAVATION PLAN
O. RAGABO
O. RAGABO
N. PLATH
R. MILLET
SPEC. NO.
1 2 3 4 5 6 7
2 3 4 5 6 71
SHEET NO. REVISION DRAWING NO.
CALIFORNIA NATURAL RESOURCES AGENCY
DIVISION OF ENGINEERING
STATE OF CALIFORNIA
DEPARTMENT OF WATER RESOURCES
THINK SAFETY -
ACT SAFELY
SUBMITTED:
DESIGNED:
DRAWN: REVIEWED:
DATE:
DATE:
REV. SUB. APP.DESCRIPTION
APPROVED:
APPROVAL RECOMMENDED:
MANAGER, GEOTECHNICAL SERVICES BRANCH, REG. C.E. No. 52754
MANAGER, GEOTECHNICAL ENGINEERING SEC., REG. C.E. No. 65001
REG. C.E. No. 42663
ABANDONED PIPES
AND CONDUITS REMOVAL
SACRAMENTO RIVER
23-17
CHECKED:
LOREN A. MURRAY
2020 L STREET SUITE 400
SACRAMENTO, CA 95811
T: (916) 414-5800
F: (916) 414-1557
A
B
C
D
NOTES:
1. CONTRACTOR SHALL REFER TO GENERAL
SHEETS FOR ADDITIONAL INFORMATION NOT
DETAILED HEREIN.
2. LOCATION OF EXCAVATION CUTS MAY VARY
BASED ON EXISTING CONDITIONS AT THE
TIME OF CONSTRUCTION.
3. ELEVATIONS SHOWN ON CROSS SECTIONS
ARE ONLY APPLICABLE TO THE REFERENCED
CROSS SECTION AND MAY VARY ACROSS THE
REPAIR.
4. REMOVE ALL BELOW GROUND ITEMS
LOCATED WITHIN THE LIMITS OF EXCAVATION
UNLESS OTHERWISE SPECIFIED BY THE
ENGINEER'S REPRESENTATIVE.
5. ANOMALOUS AREAS CONTAIN UNKNOWN
ITEMS AT VARIED DEPTHS. IT IS SUSPECTED
THAT THESE AREAS MAY INCLUDE CONCRETE
STRUCTURES, PIPES, ELECTRICAL LINES,
TELEPHONE LINES, FOUNDATIONS, AND
MISCELLANEOUS STEEL WORK. ADDITIONAL
EXCAVATION MAY BE REQUIRED TO REMOVE
THESE ITEMS.
6. CONTRACTOR SHALL REMOVE ALL PILES. IF
PILE BREAKS AT OR NEAR THE EXISTING
SUBSTRATE AND CANNOT BE REMOVED BY
OTHER METHODS, THE PILE SHALL BE CUT AT
LEAST 1' BELOW THE MUDLINE. THE PILE
DEPTHS ARE UNKNOWN.
7. THE HIGH AND LOW TIDE WATER LEVELS
SHOWN ARE APPROXIMATE AND THE TIDE
LEVELS MAY VARY DURING AT TIME OF
CONSTRUCTION.
EXCAVATION SECTIONS 1
OF 2
C-10711
DocuSign Envelope ID: 71C64730-748C-4CDE-8F79-8E1289AEFF6B
6/29/2023
V A
T
IO
N
F T
E
LE
V A
T
IO
N
F T
DISTANCE (FT)
-25
-20
-15
-10
-5
-25
-20
-15
-10
-5
0 10 20 30 40 50 60 70 80 900-10-20-30-40-50-60
WATERSIDE LANDSIDE
R E
F E
R E
N C
E L
IN
E
EL. 22.8'
EXCAVATION LIMIT
EXISTING GRADE
1.5
1.5
ELECTRICAL LINE 30" CMP
ANOMALOUS AREA
PROJECTED
36" CMP
HIGH TIDE
LOW TIDE
100510
100510
VERT SCALE: 1"=10'
HOR SCALE: 1"=10'
CROSS SECTION AT STA 11+90
A1 C-05 EXCAVATION PLAN
O. RAGABO
O. RAGABO
N. PLATH
R. MILLET
SPEC. NO.
1 2 3 4 5 6 7
2 3 4 5 6 71
SHEET NO. REVISION DRAWING NO.
CALIFORNIA NATURAL RESOURCES AGENCY
DIVISION OF ENGINEERING
STATE OF CALIFORNIA
DEPARTMENT OF WATER RESOURCES
THINK SAFETY -
ACT SAFELY
SUBMITTED:
DESIGNED:
DRAWN: REVIEWED:
DATE:
DATE:
REV. SUB. APP.DESCRIPTION
APPROVED:
APPROVAL RECOMMENDED:
MANAGER, GEOTECHNICAL SERVICES BRANCH, REG. C.E. No. 52754
MANAGER, GEOTECHNICAL ENGINEERING SEC., REG. C.E. No. 65001
REG. C.E. No. 42663
ABANDONED PIPES
AND CONDUITS REMOVAL
SACRAMENTO RIVER
23-17
CHECKED:
LOREN A. MURRAY
2020 L STREET SUITE 400
SACRAMENTO, CA 95811
T: (916) 414-5800
F: (916) 414-1557
A
B
C
D
NOTES:
1. CONTRACTOR SHALL REFER TO GENERAL
SHEETS FOR ADDITIONAL INFORMATION NOT
DETAILED HEREIN.
2. LOCATION OF EXCAVATION CUTS MAY VARY
BASED ON EXISTING CONDITIONS AT THE
TIME OF CONSTRUCTION.
3. ELEVATIONS SHOWN ON CROSS SECTIONS
ARE ONLY APPLICABLE TO THE REFERENCED
CROSS SECTION AND MAY VARY ACROSS THE
REPAIR.
4. REMOVE ALL BELOW GROUND ITEMS
LOCATED WITHIN THE LIMITS OF EXCAVATION
UNLESS OTHERWISE SPECIFIED BY THE
ENGINEER'S REPRESENTATIVE.
5. ANOMALOUS AREAS CONTAIN UNKNOWN
ITEMS AT VARIED DEPTHS. IT IS SUSPECTED
THAT THESE AREAS MAY INCLUDE CONCRETE
STRUCTURES, PIPES, ELECTRICAL LINES,
TELEPHONE LINES, FOUNDATIONS, AND
MISCELLANEOUS STEEL WORK. ADDITIONAL
EXCAVATION MAY BE REQUIRED TO REMOVE
THESE ITEMS.
6. THE HIGH AND LOW TIDE WATER LEVELS
SHOWN ARE APPROXIMATE AND THE TIDE
LEVELS MAY VARY AT THE TIME OF
CONSTRUCTION.
EXCAVATION SECTIONS 2
OF 2
C-10812
DocuSign Envelope ID: 71C64730-748C-4CDE-8F79-8E1289AEFF6B
6/29/2023
X
X
X
X
X
X
X
X
X
X X
O H
O H
11+00
12+00
10+25
12+25
P
-20
-15
-10
-5
-10
-5
NOTES:
1. SEE DRAWING C-103 FOR NOTES.
100510
SCALE: 1"=10'
SCALE: 1" = 10'
FILL PLAN
LIMITS OF
REPAIR
CONFORM TO
EXISTING GRADE
(SEE NOTE 9
DRAWING G-102)
O. RAGABO
O. RAGABO
N. PLATH
R. MILLET
FILL
SLOPE
1.5H:1V
SPEC. NO.
1 2 3 4 5 6 7
2 3 4 5 6 71
SHEET NO. REVISION DRAWING NO.
CALIFORNIA NATURAL RESOURCES AGENCY
DIVISION OF ENGINEERING
STATE OF CALIFORNIA
DEPARTMENT OF WATER RESOURCES
THINK SAFETY -
ACT SAFELY
SUBMITTED:
DESIGNED:
DRAWN: REVIEWED:
DATE:
DATE:
REV. SUB. APP.DESCRIPTION
APPROVED:
APPROVAL RECOMMENDED:
MANAGER, GEOTECHNICAL SERVICES BRANCH, REG. C.E. No. 52754
MANAGER, GEOTECHNICAL ENGINEERING SEC., REG. C.E. No. 65001
REG. C.E. No. 42663
ABANDONED PIPES
AND CONDUITS REMOVAL
SACRAMENTO RIVER
23-17
CHECKED:
LOREN A. MURRAY
2020 L STREET SUITE 400
SACRAMENTO, CA 95811
T: (916) 414-5800
F: (916) 414-1557
A
B
C
D
LIMITS OF
WORK
LANDSIDE
(SACRAMENTO RIVER)
WATERSIDE
FENCE
REFERENCE LINE
R
IVER
R O
AD
ER
ER
PUMPSTATION
BRIDGE
SUBSTATION
RETAINING WALL
ACCESS
GATE
C1
C-11
A1
C-12
A1
C-11
SOIL-FILLED
ROCKFILL
FILL SLOPE 4H:1V
ELEVATION
VARIES
EL. 25.5'
TREES
TREE
FILL SLOPE
2% GRADE (TYP)
FILL PLAN
RAILROAD TIES
N
C-10913
DocuSign Envelope ID: 71C64730-748C-4CDE-8F79-8E1289AEFF6B
6/29/2023
V A
T
IO
N
F T
E
LE
V A
T
IO
N
F T
STATION
10+50 11+00 11+50 12+00 12+25
EXISTING GRADE
FINISHED GRADE
LEVEE FILL
MIN 3" AGGREGATE BASE
2% (TYP)
2% (TYP)
ELEVATION
VARIESELEVATION VARIES
X
X
X
X
X
X
X
X
X
X
X X
11+00
12+00
10+25
12+25
100510
100510
VERT SCALE: 1"=10'
HOR SCALE: 1"=10'
O. RAGABO
O. RAGABO
N. PLATH
R. MILLET
SPEC. NO.
1 2 3 4 5 6 7
2 3 4 5 6 71
SHEET NO. REVISION DRAWING NO.
CALIFORNIA NATURAL RESOURCES AGENCY
DIVISION OF ENGINEERING
STATE OF CALIFORNIA
DEPARTMENT OF WATER RESOURCES
THINK SAFETY -
ACT SAFELY
SUBMITTED:
DESIGNED:
DRAWN: REVIEWED:
DATE:
DATE:
REV. SUB. APP.DESCRIPTION
APPROVED:
APPROVAL RECOMMENDED:
MANAGER, GEOTECHNICAL SERVICES BRANCH, REG. C.E. No. 52754
MANAGER, GEOTECHNICAL ENGINEERING SEC., REG. C.E. No. 65001
REG. C.E. No. 42663
ABANDONED PIPES
AND CONDUITS REMOVAL
SACRAMENTO RIVER
23-17
CHECKED:
LOREN A. MURRAY
2020 L STREET SUITE 400
SACRAMENTO, CA 95811
T: (916) 414-5800
F: (916) 414-1557
A
B
C
D
NOTES:
1. SEE DRAWING C-103 FOR NOTES.
LIMITS OF
REPAIR
CONFORM TO
EXISTING GRADE
(SEE NOTE 9
DRAWING G-102)
FILL
SLOPE
1.5H:1V
REFERENCE LINE
LIMITS OF
WORK
LANDSIDE
(SACRAMENTO RIVER)
WATERSIDE
R
IVER
R O
AD
FENCE
RETAINING WALL PUMPSTATION
BRIDGE
SUBSTATION
ER
ER
SCALE: 1" = 10'
FILL PLAN
SCALE: 1" = 10'
FILL PROFILE (ALONG REFERENCE LINE)
100510
SCALE: 1"=10'
SOIL-FILLED
ROCKFILL
FILL SLOPE 4H:1V
ELEVATION VARIES
EL. 25.5'
FILL SLOPE
2% GRADE (TYP)
FILL PLAN AND PROFILE
RAILROAD TIES
N
C-11014
DocuSign Envelope ID: 71C64730-748C-4CDE-8F79-8E1289AEFF6B
6/29/2023
V A
T
IO
N
F T
E
LE
V A
T
IO
N
F T
DISTANCE (FT)
-25
-20
-15
-10
-5
-25
-20
-15
-10
-5
0 10 20 30 40 50 60 70 80 900-10-20-30-40-50-60
WATERSIDE LANDSIDE
R E
F E
R E
N C
E L
IN
E
EXISTING GRADE
1.5
EL. 25.5'
LEVEE FILL (SEE NOTE 2)
MIN 3" AGGREGATE BASE
(SEE NOTE 4)
2% (TYP)
SOIL-FILLED
ROCKFILL
(SEE NOTE 7)
GEOTEXTILE FABRIC
(SEE NOTE 8)
ELEVATION VARIES
HIGH TIDE
LOW TIDE
FINISHED GRADE
E
LE
V A
T
IO
N
F T
E
LE
V A
T
IO
N
F T
DISTANCE (FT)
-25
-20
-15
-10
-5
-25
-20
-15
-10
-5
0 10 20 30 40 50 60 70 80 900-10-20-30-40-50-60
WATERSIDE LANDSIDE
R E
F E
R E
N C
E L
IN
E
FINISHED GRADE
EXISTING GRADE
LEVEE FILL (SEE NOTE 2)
MIN 3" AGGREGATE BASE
(SEE NOTE 4) 2% (TYP)
ELEVATION VARIES
100510
100510
VERT SCALE: 1"=10'
HOR SCALE: 1"=10'
CROSS SECTION AT STA 11+00
C1
CROSS SECTION AT STA 10+60
A1
C-09 FILL PLAN
C-09 FILL PLAN
O. RAGABO
O. RAGABO
N. PLATH
R. MILLET
SPEC. NO.
1 2 3 4 5 6 7
2 3 4 5 6 71
SHEET NO. REVISION DRAWING NO.
CALIFORNIA NATURAL RESOURCES AGENCY
DIVISION OF ENGINEERING
STATE OF CALIFORNIA
DEPARTMENT OF WATER RESOURCES
THINK SAFETY -
ACT SAFELY
SUBMITTED:
DESIGNED:
DRAWN: REVIEWED:
DATE:
DATE:
REV. SUB. APP.DESCRIPTION
APPROVED:
APPROVAL RECOMMENDED:
MANAGER, GEOTECHNICAL SERVICES BRANCH, REG. C.E. No. 52754
MANAGER, GEOTECHNICAL ENGINEERING SEC., REG. C.E. No. 65001
REG. C.E. No. 42663
ABANDONED PIPES
AND CONDUITS REMOVAL
SACRAMENTO RIVER
23-17
CHECKED:
LOREN A. MURRAY
2020 L STREET SUITE 400
SACRAMENTO, CA 95811
T: (916) 414-5800
F: (916) 414-1557
A
B
C
D
NOTES:
1. CONTRACTOR SHALL REFER TO GENERAL
SHEETS FOR ADDITIONAL INFORMATION NOT
DETAILED HEREIN.
2. PLACE LEVEE FILL IN HORIZONTAL LIFTS
AGAINST VERTICAL FACES CUT INTO THE
EXISTING LEVEE MATERIAL IN ACCORDANCE
WITH SPECIFICATION SECTION 02300
EARTHWORK. SLOPE BENCHING SHALL BE A
MAXIMUM HEIGHT OF 12" AND NO STEEPER
THAN 1H:1V. SEE DRAWING C-112 DETAIL C1.
3. ELEVATIONS SHOWN ON CROSS SECTIONS
ARE ONLY APPLICABLE TO THE REFERENCED
CROSS SECTION AND MAY VARY ACROSS THE
REPAIR.
4. PLACE AND COMPACT 3" MINIMUM
AGGREGATE BASE RESURFACING MATERIAL
TO MATCH EXISTING GRADE. SEE DRAWING
C-112 DETAIL C4.
5. THE HIGH AND LOW TIDE WATER LEVELS
SHOWN ARE APPROXIMATE AND THE TIDE
LEVELS MAY VARY AT THE TIME OF
CONSTRUCTION.
6. SEE DRAWING G-103 FOR EROSION CONTROL
FABRIC INSTALLATION DETAILS.
7. SOIL-FILLED ROCKFILL DEPTH BETWEEN
LEVEE FILL AND FINISHED GRADE SHALL BE 3'
MINIMUM THICKNESS MEASURED
PERPENDICULAR TO SLOPE. SEE THIS SHEET
DETAIL B5. SEE SPECIFICATION SECTION
02371 FOR THE GRADATION.
8. INSTALL GEOTEXTILE FABRIC BETWEEN
DISSIMILAR MATERIALS AS DIRECTED IN
SPECIFICATION SECTION 02650 GEOTEXTILE
FABRIC.
TYPICAL SOIL-FILLED ROCK PLACEMENT DETAIL
SCALE: NTSB5
EXISTING
GRADE
LEVEE FILL
SOIL-FILLED
ROCKFILL
GEOTEXTILE
FABRIC
(SEE NOTE 8)
4' M
IN
MIN 3" AGGREGATE BASE
1.5
EXCAVATION LIMIT
(BOTTOM OF EXCAVATION)
2% (TYP)
EROSION CONTROL FABRIC
(SEE NOTE 6)
6" AGRICULTURAL SOIL
SEEDING
FILL SECTIONS 1 OF 2
2'
3'
1.5
C-11115
DocuSign Envelope ID: 71C64730-748C-4CDE-8F79-8E1289AEFF6B
6/29/2023
V A
T
IO
N
F T
E
LE
V A
T
IO
N
F T
DISTANCE (FT)
-25
-20
-15
-10
-5
-25
-20
-15
-10
-5
0 10 20 30 40 50 60 70 80 900-10-20-30-40-50-60
WATERSIDE LANDSIDE
R E
F E
R E
N C
E L
IN
E
FINISHED GRADE EXISTING GRADE
LEVEE FILL (SEE NOTE 2)
MIN 3" AGGREGATE BASE
(SEE NOTE 4) 2% (TYP)
ELEVATION VARIES
HIGH TIDE
LOW TIDE
100510
100510
VERT SCALE: 1"=10'
HOR SCALE: 1"=10'
CROSS SECTION AT STA 11+90
A1 C-09 FILL PLAN
O. RAGABO
O. RAGABO
N. PLATH
R. MILLET
SPEC. NO.
1 2 3 4 5 6 7
2 3 4 5 6 71
SHEET NO. REVISION DRAWING NO.
CALIFORNIA NATURAL RESOURCES AGENCY
DIVISION OF ENGINEERING
STATE OF CALIFORNIA
DEPARTMENT OF WATER RESOURCES
THINK SAFETY -
ACT SAFELY
SUBMITTED:
DESIGNED:
DRAWN: REVIEWED:
DATE:
DATE:
REV. SUB. APP.DESCRIPTION
APPROVED:
APPROVAL RECOMMENDED:
MANAGER, GEOTECHNICAL SERVICES BRANCH, REG. C.E. No. 52754
MANAGER, GEOTECHNICAL ENGINEERING SEC., REG. C.E. No. 65001
REG. C.E. No. 42663
ABANDONED PIPES
AND CONDUITS REMOVAL
SACRAMENTO RIVER
23-17
CHECKED:
LOREN A. MURRAY
2020 L STREET SUITE 400
SACRAMENTO, CA 95811
T: (916) 414-5800
F: (916) 414-1557
A
B
C
D
EXISTING
GRADE
LIMITS OF
EXCAVATION
1' MAX
1.5
TYPICAL SLOPE BENCHING DETAIL
SCALE: NTSC1
NOTES:
1. CONTRACTOR SHALL REFER TO GENERAL
SHEETS FOR ADDITIONAL INFORMATION NOT
DETAILED HEREIN.
2. PLACE LEVEE FILL IN HORIZONTAL LIFTS
AGAINST VERTICAL FACES CUT INTO THE
EXISTING LEVEE MATERIAL IN ACCORDANCE
WITH SPECIFICATION SECTION 02300
EARTHWORK. SLOPE BENCHING SHALL BE A
MAXIMUM HEIGHT OF 12" AND NO STEEPER
THAN 1H:1V. SEE THIS DRAWING DETAIL C1.
3. ELEVATIONS SHOWN ON CROSS SECTIONS
ARE ONLY APPLICABLE TO THE REFERENCED
CROSS SECTION AND MAY VARY ACROSS THE
REPAIR.
4. PLACE AND COMPACT 3" MINIMUM
AGGREGATE BASE RESURFACING MATERIAL
TO MATCH EXISTING GRADE. SEE THIS SHEET
DETAIL C4.
5. THE HIGH AND LOW TIDE WATER LEVELS
SHOWN ARE APPROXIMATE AND THE TIDE
LEVELS MAY VARY AT THE TIME OF
CONSTRUCTION.
TYPICAL AGGREGATE BASE RESURFACING DETAIL
SCALE: NTSC4
EXISTING
GRADE
MIN 3" AGGREGATE BASE
LEVEE FILL
2% (TYP)
FILL SECTIONS 2 OF 2
C-11216
DocuSign Envelope ID: 71C64730-748C-4CDE-8F79-8E1289AEFF6B
6/29/2023
| 01 - G-101 - COVER SHEET |
| 02 - G-102 - NOTES, LEGEND, AND ABBREVIATIONS |
| 03 - G-103 - EROSION CONTROL FABRIC DETAILS |
| 04 - V-101 - SURVEY CONTROL |
| 05 - C-101 - SITE ACCESS |
| 06 - C-102 - STAGING AND LAYDOWN AREAS |
| 07 - C-103 - SITE PLAN |
| 08 - C-104 - DEMOLITION PLAN |
| 09 - C-105 - EXCAVATION PLAN |
| 10 - C-106 - EXCAVATION PLAN AND PROFILE |
| 11 - C-107 - EXCAVATION SECTIONS 1 OF 2 |
| 12 - C-108 - EXCAVATION SECTIONS 2 OF 2 |
| 13 - C-109 - FILL PLAN |
| 14 - C-110 - FILL PLAN AND PROFILE |
| 15 - C-111 - FILL SECTIONS 1 OF 2 |
| 16 - C-112 - FILL SECTIONS 2 OF 2 |