This is a Work Write-Up (Exhibit 1) prepared by the City of Jackson Community Development Department for a housing rehabilitation project at 225 W High Street, Jackson, Michigan, dated February 11, 2026. The scope of work includes three primary components: roof strip and installation (R05), gutterwork (G08), and porch beam straightening and installation. The roofing work requires removal of existing shingles and felt, repair of roof framing as needed, installation of 7/16" oriented-strand board sheathing, ice shield at lower roof edges extending 24" inside the interior wall line, 15% asphalt saturated felt, and new architectural-style roofing material with metal drip and rake edges, valley materials, chimney and vent reflashing, and ridge venting. The project includes approximately unspecified squares of new roofing material and approximately 130 linear feet of gutters and 60 linear feet of downspouts. The gutterwork requires installation of baked pre-enameled aluminum 5-inch K-type gutters and downspouts with proper pitch and water diversion. The porch work involves straightening and realigning the porch system with new treated wood posts (6x6 notched) and beam (2-2x10) with proper fastening and infill work. Permits and inspections are required for roof and porch work.
The document does not contain specific pricing information, contract award dates, response deadlines, site visit requirements, or bidder conference details. The work write-up indicates that the customer (Lekedia Baltimore) and contractor must sign the document only if it becomes part of a construction contract and both parties have reviewed and approved the work and prices described. The document was prepared by sharrison@cityofjackson.org and is part of the City of Jackson's competitive sealed bid process for qualified contractors participating in the Community Development Department's housing rehabilitation program for qualified homeowners.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 225_W_High_St_-_Strip_and_Replace_Roof,_New_Gutters,_Install_Porch_Beam.pdf | ||
| Performance_Bond.pdf | ||
| Maintenance_and_Guarantee_Bond.pdf | ||
| Labor_and_Material_Payment_Bond.pdf | ||
| All_Services_Sample_Contract_.docx | DOCX document | |
| CDBG_Additional_Forms.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Work Write-Up
R05 - ROOF - STRIP AND INSTALL
* EXHIBIT 1 *
Dated: 2/11/2026
CUSTOMER INFORMATION
Lekedia Baltimore 225 W High St, Jackson, MI 49203
PREPARED BY
sharrison@cityofjackson.org
* NOTE *
THE CUSTOMER AND CONTRACTOR MUST SIGN THE BOTTOM OF EACH PAGE ONLY IF
1) THIS WORK WRITE-UP BECOMES PART OF A CONSTRUCTION CONTRACT
2) THE UNDERSIGNED CUSTOMER AND CONTRACTOR HAVE REVIEWED, APPROVED AND AGREED TO THE WORK AND PRICES DESCRIBED IN THIS WORK WRITE-UP
Location: Unassigned
| General Requirements |
| Quantity |
| Units |
| Total |
1 - R05 - ROOF - STRIP AND INSTALL
(Specification ID:1.05000 )
Sq
*PERMIT REQUIRED*
Strip existing roof, removing all shingles and felt. Make repairs to the existing roof framing where required to provide adequate strength and a true and level surface. Install 7/16” oriented-strand board sheathing to cover all areas of roof deck. Just before proceeding, sweep roof thoroughly to remove all debris. Install ice shield at all lower roof edges. Ice shield shall extend at least 24" inside the interior surface of the exterior wall line of the building, in accordance with the Michigan Building Code. Install new 15% asphalt saturated felt according to manufacturer's directions. Furnish and install new roofing material of a color as selected by owner, must be architectural style. Installation shall include metal drip and rake edge, two layers of 90# roll valley or metal valley in all valleys. Reflash chimney, plumbing vents, and vertical walls with appropriate neoprene boots and metal step flashing where possible. Install ventilation units sufficient to vent all areas of attic. Ridge venting when used shall cover the full length of the roof ridge. Installation of all materials shall follow manufacturer's printed instructions and G.S. 1.
Contractor is responsible for final measurement.
To include the flat roof on the south side of the home. Strip and replace with a Modified roofing material, installed according to manufactures instructions.
Approximately __________ squares on__________ New roofing material type shall be architectural shingles Manufacturer: __________ Color Name/Number: __________
Contractor's Initials: ____________________
Owner's Initials: __________
Rehab Initials: ___________
2 - G08 - GUTTERWORK
(Specification ID:1.08000 )
LF
Furnish and install gutter and downspout. Replacements shall match existing as to materials, finish, shape and size. Do not mix galvanized with copper or aluminum. Where replacements are of a complete system or side of a system having no cross connections with sections not to be replaced, used baked pre-enameled aluminum, 5-inch K-type in standard colors. Minimum thickness of aluminum shall be .027 inches for troughs and fittings. Use one or a combination of strap hangers, spike and ferrules or fascia hangers. Space hangers and slip joint connectors per manufacturer's instructions. Maximum spacing of hangers shall be 48 inches OC for galvanized and 30 inches for aluminum. Use only recommended gutter seal and rivets or screws at all joints. All work, whether a complete new system or a partial replacement, shall have the system with a pitch of not less than 1 inch in 16 feet. Divert the water away from the foundation using appropriate extensions and/or concrete splash blocks. All work to conform to code and G.S. 4a.
Contractor responsible for final measurements.
All downspouts shall be commercial size. Current color is a dark brown, the new shall be a close match if not the same color.
Approximately 130 linear feet of gutter on all elevation(s).
Approximately 60 linear feet of downspout on all elevation(s)
Subtotal for General Requirements
| Porches & Entrances |
| Quantity |
| Units |
| Total |
3 - STRAIGHTEN PORCH BEAM AND POSTS
(Specification ID:40.09500 )
EA
Straighten, realign and add footing to porch system, beam and posts/columns. Reattach beam and posts/columns to adjacent building components.
Install of one separate porch beam, running the length of the porch, One post on each end and one in the center. There is an access door in the basement. Northwest side has dropped some lift will be required prior to full set of beams and posts. Ensure porch is properly fasten to the home.
Permit required. Inspection of the post holes will be required. All material shall be treated wood with exterior fasteners.
Infill, Tuckpoint area between the wood and the cement/ Block wall.
To include removing debris from the crawl space area.
Posts shall be 6x6 notched to allow beam to site on post, Beam size shall be 2- 2x10.
Contractor responsible for all field measurements and conditions.
Total
Prepared By: sharrison@cityofjackson.org on 2/11/2026
OWNER ACCEPTS SCOPE OF WORK
I have read the contents of this work write up and received a copy. I fully understand the repairs to be made to my property.
| x_________________________ | __________ | |
| Owner: | Date |
CONTRACTOR ACCEPTS SCOPE OF WORK
I have read the contents of this work write up and agree to perform all work called for in accordance with the bid submitted on __________.
| x_________________________ | __________ | |
| Contractor | Date |
| x____________________________ | __________ | |
| Construction Specialist | Date |
| Prepared By: sharrison@cityofjackson.org on 2/11/2026 |