224520Plans03312025.pdf
PDF 3 MB Posted
- Attached to
- Athletic Restroom Construction
- Solicitation number
- RFP-EAPS-250000001978-1
- Issued by
- Delta County, Michigan
About this file
The document is a comprehensive set of architectural and engineering construction plans for the Escanaba Area Public Schools' Junior/Senior High School Athletic Restroom Building project located at 500 S. Lincoln Road in Escanaba, Michigan. The project involves constructing a new athletic restroom facility, with two potential alternates: installing a 6-foot wide sidewalk from the restroom building to the proposed tennis pavilion, and including an additional 2-inch buried conduit with pull wire from the existing high school to the new restroom building. The project documents include detailed civil, structural, architectural, mechanical, electrical, and plumbing plans, with specifications covering everything from site grading and utility connections to building materials, fixtures, and system installations.
The project is designed for a relatively compact athletic restroom building with men's and women's facilities, including ADA-compliant fixtures such as toilets, urinals, lavatories, and a drinking fountain. The estimated project cost is not explicitly stated, but the comprehensive nature of the plans suggests a substantial investment in infrastructure. The plans indicate careful consideration of site access, existing utilities, and potential disruptions to school activities, with specific notes about working around tennis court schedules and student traffic. The design incorporates modern building standards, including energy efficiency, accessibility requirements, and consideration of local environmental conditions. The project appears to be funded through the school district's capital improvement or construction budget, with the plans prepared by Dynamic Design Group, Inc., an engineering and architectural firm located in Escanaba.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 224520Specs03312025.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Z:
\0
0- D
W G
\0 0-
E sc an ab a Ar ea P ub lic
S ch oo ls
\2 2-
H ig h Sc ho ol
A th le tic
B at hr oo m B ui ld in g, E sc an ab a, M
I\2 2-
_C O
VE
R
S H
EE
T x2
2.
dw g
/3
1/
0:
:0
AM
Mdd Dynamic Design Group, inc.
P.O. Box 1064 900 1st Ave. So., Ste. A Escanaba, MI ph.: 906.786.3300 fax: 906.233.7391 email: gen@ddgi-ddm.com www.ddgi-ddm.com
PROJECT TITLE:
OWNER:
DESIGNER:
G0.1
JUNIOR/SENIOR HIGH SCHOOL
500 S. LINCOLN ROAD, ESCANABA, MICHIGAN
ATHLETIC RESTROOM BUILDING
ESCANABA, MI 49829
1500 LUDINGTON STREET
ESCANABA AREA PUBLIC SCHOOLS
FOR REVIEW/FOR CONSTRUCTION
SET DATE: 03-31-2025
JOB NO.: 22-4520
THREE FULL WORKING DAYS
BEFORE YOU DIG, CALL THE
"MISS DIG" SYSTEM AT
1-(800)-482-7171 OR 811
DELTA COUNTY
PROJECT LOCATION
LOCATION MAPS
03-31-2025
SHT. NO. TITLE SHEET SHEET ISSUE DATE
G0.1 TITLE SHEET 03-31-2025
G0.2 NOTES AND ABBREVIATIONS 03-31-2025
G0.3 ARCHITECTURAL DETAILS 03-31-2025
C1.0 SURVEY, SOIL BORINGS, SOIL EROSION INFORMATION 03-31-2025
C2.0 EXISTING SITE/UTILITY/DEMO PLAN AND EXISTING GRADES PLAN 03-31-2025
C3.0 PROPOSED SITE PLAN AND PROPOSED GRADES PLAN AND DETAILS 03-31-2025
A1.0 FLOOR PLAN, ENLARGED PLAN AND ELEVATIONS 03-31-2025
A1.1 BUILDING SECTIONS 03-31-2025
A1.2 SCHEDULES 03-31-2025
S1.0 FOUNDATION PLAN AND DETAILS 03-31-2025
S1.1 CONCRETE SLAB PLAN AND DETAILS 03-31-2025
E0.1 ELECTRICAL SPECIFICATIONS 03-31-2025
E1.0 ELECTRICAL SITE PLAN 03-31-2025
E1.1 ELECTRICAL POWER/MECHANICAL PLAN AND LIGHTING PLAN 03-31-2025
E2.1 ELECTRICAL SCHEDULES AND PANEL 03-31-2025
M0.1 MECHANICAL LEGEND AND SPECIFICATIONS 03-31-2025
M1.1 MECHANICAL VENTILATION PLAN, SCHEDULES AND DETAILS 03-31-2025
P0.1 PLUMBING LEGEND AND SPECIFICATIONS 03-31-2025
P0.2 PLUMBING SPECIFICATIONS 03-31-2025
P1.0 PLUMBING DOMESTIC WATER SITE PLAN 03-31-2025
P1.1 PLUMBING WASTE AND VENTING PLANS AND DOMESTIC PIPING PLAN 03-31-2025
P2.1 PLUMBING FIXTURE SCHEDULE AND TUNNEL DETAIL 03-31-2025
P2.2 PLUMBING WASTE AND VENT AND DOMESTIC WATER ISOMETRICS 03-31-2025
SHEET INDEX
ALTERNATES:
ALTERNATE #1 - 6FT WIDE SIDEWALK FROM THE RESTROOM BUILDING TO THE PROPOSED TENNIS PAVILION.
ALTERNATE #2 - INCLUDE AN ADDITIONAL 2" BURIED CONDUIT (AND PULL WIRE) FROM THE EXISTING HIGH SCHOOL TO THE NEW RESTROOM BUILDING AND UPSIZE THE 1" WATER SUPPLY PIPE TO A 2" WATER SUPPLY PIPE.
CODES REFERENCED:
2015 MICHIGAN BUILDING CODE
2021 MICHIGAN MECHANICAL CODE
2021 MICHIGAN PLUMBING CODE
2023 NATIONAL ELECTRIC CODE (NEC)
2009 ICC/ANSI A117.1 - ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
2015 MICHIGAN RESIDENTIAL CODE
2015 MICHIGAN REHABILITATION CODE FOR EXISTING BUILDINGS
2015 MICHIGAN ENERGY CODE
BUILDING DATA:
AREA:
NEW: = 352 SF
BUILDING CODE DATA:
3 302 Classification Chapter Section/Table Allowable Actual
E-Educational Remarks
5 352 SFMAIN = 9000 SF
Table 503 Area Table 503 - Height5 506 Bldg. Area Modification5 not req'd.
6 602 Types of Construction VB
Table 508.4 - Req'd.
Separation of Occupancies not req'd.
9 903 Auto. Sprinkler System not req'd.
9 906 Fire Extiguishers 1not req'd
Table 1004.1.1 23 occupantsE=50 net Flr. Area per Occ.
Section 1015
1 Exit Req'd. 1 @ each space No. of Exits Req'd.
BUILDING AND CODE DATA
GENERAL NOTES:
1. SITE ACCESS - CONTRACTOR SHALL ACCESS THE ATHLETIC RESTROOM BUILDING LOCATION FROM THE SOUTH PARKING LOT, TRAVELING BETWEEN THE SCHOOL BUILDING
AND THE EXISTING NORTH TENNIS COURTS. CONTRACTOR SHALL AVOID THE EXISTING MANHOLES LOCATED IN THIS AREA AND SHALL AVOID TRAFFIC OVER THE BURIED PIPING. CONTRACTOR SHALL REPAIR ALL EXISTING GRASS AREAS, CURBS, SIDEWALKS, ETC. TO THE ORIGINAL OR BETTER CONDITION. IF WORK ON THE ATHLETIC RESTROOM BUILDING OCCURS AFTER THE FIRST DAY OF SCHOOL, THEN EXTRA CARE MUST BE TAKEN WHILE TRAVELING THROUGH THE SCHOOL PROPERTY, SPECIFICALLY AROUND AREAS OF STUDENT ACTIVITY, SUCH AS AROUND THE VEHICLES OF THE SOUTH PARKING LOT AND AROUND THE TENNIS COURTS. CONTRACTORS ACCESSING THE SITE THROUGH THE SOUTH PARKING LOT MUST TRAVEL AT SLOW SPEEDS, NOT EXCEEDING 10MPH. CONTRACTOR SHOULD ATTEMPT TO AVOID THE INTERACTION WITH STUDENTS/STAFF AT THE BEGINNING AND END OF THE SCHOOL DAY (7AM TO 8AM AND 2PM TO 3PM).
CONTRACTOR SHALL BE AWARE THAT THE EXISTING TENNIS COURTS WILL BE UTILIZED IN THE AFTERNOONS FOR FALL TENNIS PRACTICES AND EVENTS. PRACTICES WILL LIKELY START AROUND AUGUST 11TH AND EVENTS WILL LIKELY START AROUND AUGUST 16TH. CONTRACTOR WILL BE ABLE TO COMPLETE ANY WORK DURING TENNIS PRACTICES, HOWEVER, DURING TENNIS EVENTS, CONTRACTOR WILL ONLY BE ABLE TO COMPLETE INSIDE WORK. NO OUTSIDE WORK THAT IS NOISY OR DUSTY WILL BE ALLOWED AND NO EQUIPMENT SHALL BE DRIVEN AROUND THE TENNIS COURTS DURING TENNIS EVENTS. CONTRACTOR SHALL COORDINATE THE TENNIS EVENT SCHEDULE WITH THE OWNER, TO DETERMINE WHEN THESE DATES WILL OCCUR. THE OWNER MAY ELECT TO RELOCATE PRACTICES TO ALTERNATE LOCATIONS AS NEEDED, ON A
LIMITED BASIS.
2. SITE ACCESS THROUGH THE EXISTING FENCE.
TO ACCESS THE SITE, THE CONTRACTOR WILL NEED TO PULL BACK THE EXISTING CHAIN-LINK FABRIC IMMEDIATELY EAST OF THE BUILDING LOCATION, NORTH OF THE EXISTING TENNIS COURTS. CONTRACTOR MAY REMOVE FENCE POSTS AS WELL. CONTRACTOR SHALL NOT MODIFY THE EXISTING TENNIS COURT FENCING IN ANY WAY.
CONTRACTOR SHALL RETURN THE EXISTING FENCING TO THE ORIGINAL OR BETTER CONDITION, BY INSTALLING NEW POSTS FOR ANY POSTS PULLED OUT AND RE-INSTALLING THE EXISTING FABRIC, OR REPLACING THE FABRIC WITH NEW, IF NECESSARY. CONTRACTOR SHALL NOT RE-USE ANY EXISTING POSTS THAT ARE PULLED
OUT OF THE GROUND, UNLESS APPROVED BY THE ENGINEER OR OWNER.
3. WEST PARKING LOT
CONTRACTOR FOR THE ATHLETIC RESTROOM BUILDING WILL NOT HAVE ACCESS TO THE ATHLETIC RESTROOM BUILDING LOCATION FROM THE NORTH, THROUGH THE WEST PARKING LOT. CONTRACTOR SHALL NOT UTILIZE THE WEST PARKING LOT IN ANY WAY, FOR PASSAGE, EMPLOYEE PARKING, EQUIPMENT, TRUCKS, ETC.. CONTRACTOR SHALL NOT UTILIZE THE ASPHALT SIDEWALK THAT IS LOCATED FROM THE WEST PARKING LOT TO THE TRACK. CONTRACTOR HAS ACCESS TO THE SITE FROM THE SOUTH
PARKING LOT. SEE PREVIOUS NOTE.
4. UNDERGROUND STORM PIPE
A NEW UNDERGROUND STORM PIPE WAS PLACED IN THE SUMMER OF 2022 FROM THE WEST PARKING LOT TO THE STORM MANHOLE AT THE SOUTHWEST CORNER OF THE SCHOOL BUILDING. TWO CONDUITS WERE PLACED ACROSS THE STORM PIPE, FOR THE INSTALLATION OF THE UTILITIES FOR THIS PROJECT. CONTRACTOR SHALL AVOID AND PROTECT THE STORM PIPE AND ALL OTHER ON-SITE UTILITIES, DURING THE TRENCHING FOR THE NEW UTILITIES.
PROJECT LOCATION
ABBREVIATIONS
1. GENERAL
1.1. THE WORD "CONTRACTOR" MEANS, THE PRIME
CONTRACTOR OR THE CONTRACTOR SCHEDULED TO
PERFORM THE WORK.
1.2. CONTRACTOR AND ALL SUBCONTRACTORS SHALL
FAMILIARIZE HIMSELF WITH THE ENTIRE SET OF
CONSTRUCTION DOCUMENTS AND MAKE HIMSELF AWARE
OF OTHER DISCIPLINES WORK THAT MAY AFFECT HIS.
1.3. CONTRACTOR AND ALL SUBCONTRACTORS SHALL VISIT THE
BUILDING SITE AND MAKE HIMSELF AWARE OF CONDITIONS
THAT MAY AFFECT HIS WORK.
1.4. CONTRACTOR IS RESPONSIBLE FOR AND SHALL INCLUDE
PROVISIONS IN HIS BID FOR COORDINATING WORK
BETWEEN OTHER TRADES.
1.5. CONTRACTOR AND ALL SUBCONTRACTORS SHALL
COMPLETELY REVIEW EVERY DRAWING AND SPECIFICATION
TO HAVE A COMPLETE UNDERSTANDING OF THE ENTIRE
PROJECT AND THE WORK THAT MAY BE AFFECTED BY HIS
WORK AND THE WORK OF OTHER DISCIPLINES THAT MAY
AFFECT HIS WORK.
1.6. DO NOT SCALE DRAWINGS. USE DIMENSIONS AND
ELEVATIONS PROVIDED. IF DIMENSIONS AND ELEVATIONS
ARE IN QUESTION, CONTRACTOR SHALL CONTACT THE
OFFICE OF THE ENGINEER BEFORE CONTINUING WITH
WORK.
1.7. EACH CONTRACTOR SHALL VERIFY ALL CONDITIONS AND
DIMENSIONS AND ELEVATIONS AT THE SITE. NEITHER THE
OWNER NOR DYNAMIC DESIGN GROUP, INC. ASSUMES
RESPONSIBILITY FOR CONDITIONS OR DIMENSIONS THAT
ARE EXISTING OR SHOWN AS EXISTING. IF EXISTING ITEMS
ARE DIMENSIONED - DIMENSIONS ARE FOR BIDDING
PURPOSES ONLY AND SHALL BE VERIFIED BY CONTRACTOR.
1.8. ALL HOLES FOR PLUMBING, ELECTRICAL, OR HVAC;
CONDUITS, PIPING, DUCTWORK ARE TO BE REPAIRED BY
THE ASSOCIATED TRADE. ALL TRADES SHALL TAKE CARE
TO MAKE HOLES ONLY AS LARGE AS REQUIRED, ALL HOLES
SHALL BE NEATLY CUT.
1.9. HOLES IN WALLS OR FLOORS SHALL BE PROPERLY SEALED.
1.10. FIELD VERIFY ALL DOOR AND WINDOW ROUGH OPENING
SIZES PRIOR TO ORDERING OR INSTALLATION.
1.11. WHEN CONTRADICTIONS OCCUR BETWEEN THE PLANS AND
THE SPECIFICATIONS AND/OR ERRORS ARE FOUND IN
EITHER, THE CONTRACTOR SHALL OBTAIN CLARIFICATION
FROM THE OFFICE OF THE ENGINEER BEFORE CONTINUING
WITH CONSTRUCTION.
1.12. CONSTRUCTION SHALL BE IN ACCORDANCE WITH THESE
PLANS, THE CURRENT MICHIGAN BUILDING CODES, ALL
LOCAL ORDINANCES AND NORMAL INDUSTRY STANDARDS.
1.13. CONTRACTOR IS TO OBTAIN AND PAY FOR PERMITS,
LICENSES, FEES, INSPECTIONS, ETC. AS MAY BE REQUIRED
FOR HIS CONTRACTED WORK, FOR COMPLETION OF HIS
OWN PORTION OF THE PROJECT.
1.14. CONTRACTOR IS RESPONSIBLE FOR CONTACTING "MISS
DIG" PRIOR TO PERFORMING ANY EXCAVATION.
1.15. CONTRACTOR SHALL REMOVE ALL CONSTRUCTION RUBBISH
AND DEMOLISHED MATERIALS GENERATED UNDER HIS
CONTRACTED PORTION OF THE WORK, FROM THE SITE ON
A WEEKLY BASIS AND AT THE END OF THE JOB AND SHALL
DISPOSE OF APPROPRIATELY. THE ENTIRE PROJECT SHALL
BE LEFT BROOM CLEAN.
1.16. CONTRACTOR SHALL FOLLOW "OCCUPATIONAL SAFETY AND
HEALTH ACT" REQUIREMENTS ISSUED BY THE STATE AND
LOCAL LAWS, RULES AND REGULATIONS AS THEY APPLY.
1.17. ALL MATERIALS AND EQUIPMENT INCORPORATED INTO THE
WORK SHALL BE NEW, UNLESS OTHERWISE APPROVED BY
THE OWNER AND ENGINEER.
1.18. CONTRACTOR SHALL BE RESPONSIBLE FOR THE ERECTION
AND MAINTENANCE OF ALL BARRICADES, GUARDRAILS,
LIGHTS AND SIGNS NECESSARY FOR PUBLIC SAFETY.
1.19. CONTRACTOR SHALL PROVIDE PROTECTION AGAINST RAIN,
WIND, STORMS, COLD OR HEAT SO AS TO MAINTAIN ALL
WORK, MATERIALS, APPARATUS, EQUIPMENT AND
FIXTURES UNDER HIS CONTRACT, INCORPORATED IN THE
WORK OR STORED ON SITE FREE FROM INJURY OR
DAMAGE. COVER ALL NEW WORK LIKELY TO BE DAMAGED
ON A DAILY BASIS. ITEMS WHICH REQUIRE DRY STORAGE
SHALL BE STORED IN A DRY BUILDING AND NOT UNDER
TARPS.
1.20. PROVIDE LINTELS/HEADERS AS REQUIRED FOR ALL
MECHANICAL DUCTWORK, LOUVERS, DOORS, OPENINGS,
ETC. WHETHER SPECIFICALLY CALLED OUT ON PLANS OR
NOT.
1.21. CONTRACTOR SHALL PROVIDE AS-BUILTS OF ALL WORK
AND DISCIPLINES AT THE END OF THE PROJECT BEFORE
FINAL PAYMENT IS AUTHORIZED.
1.22. CONTRACTOR SHALL PROVIDE AT LEAST ONE PORTABLE
TOILET TO BE USED/SHARED BY ALL WORKERS ON THE
JOBSITE.
2. CIVIL
2.1 CONTRACTOR IS RESPONSIBLE FOR PERFORMING
STANDARD MEASURES FOR SOIL EROSION AND SEDIMENT
CONTROL AS REQUIRED BY CODE AND LOCAL ORDINANCES
PRIOR TO PERFORMING ANY SITE WORK.
2.2 SOIL SHALL BE GRADED TO PROVIDE DRAINAGE AWAY
FROM THE BUILDING. MAINTAIN THE GRADE LEVELS SHOWN
ON THE PLANS AROUND THE BUILDING PERIMETER AND/OR
AS REQUIRED BY THE CURRENT APPLICABLE CODE.
2.3 ALL CONCRETE SLABS ON GRADE SHALL BE PLACED ON
WELL COMPACTED UNDISTURBED VIRGIN SOIL OR
APPROVED STRUCTURAL FILL AND IT SHALL BE 95%
PROCTOR DENSITY OR BETTER.
2.4 CONTRACTOR IS RESPONSIBLE FOR ALL STAKE OUT
NECESSARY TO COMPLETE THE WORK.
2.5 ALL EXISTING NATIVE MATERIAL AND/OR APPROVED
SUBBASE SHALL BE AGGRESSIVELY COMPACTED PRIOR TO
INSTALLING COMPACTED FILL OVER IT TO PREVENT
SETTLING DURING THE INSTALLATION OF THE COMPACTED
FILL OR SETTLING DURING INSTALLATION OF PAVING,
CONCRETE, ETC. CONTRACTOR'S INSTALLATION OF FILL,
PAVING, CONCRETE, ETC. OVER THE NATIVE MATERIAL OR
SUBBASE IS CONTRACTORS ACCEPTANCE/APPROVAL OF
THE NATIVE MATERIAL OR SUBBASE. ALL SETTLING OF
ASPHALT, CONCRETE, ETC. THAT IS DUE TO FAULTY NATIVE
MATERIAL AND/OR SUBBASE SHALL BE REPAIRED BY THE
CONTRACTOR.
3. CIVIL/STRUCTURAL
3.1. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE SOIL
CONDITIONS DESCRIBED IN THE DRAWINGS,
SPECIFICATIONS (IF PROVIDED) OR THE GEOTECHNICAL
REPORT/SOIL BORINGS (IF PROVIDED).
3.2. THE OWNER IS ENCOURAGED TO OBTAIN A GEOTECHNICAL
REPORT/SOIL BORINGS. IF NO GEOTECHNICAL
REPORT/SOIL BORINGS ARE PROVIDED 2000 PSF SOIL
BEARING CAPACITY IS PRESUMED. IF SOILS OTHER THAN
SANDY, SANDY GRAVEL, GRAVEL OR (SW, SP, SM, SC, GM or
GC) AS DEFINED BY THE 2009 MICHIGAN BUILDING CODE,
ARE ENCOUNTERED NOTIFY THE OFFICE OF THE ENGINEER.
3.3. FILL SHALL BE A GRANULAR MATERIAL, FREE FROM DEBRIS
AND STONES OVER 4" DIAMETER AND REASONABLY
GRADED.
4. STRUCTURAL - GENERAL
4.1. DESIGN LOADS
4.1.1. RISK CATEGORY = II
4.1.2. SNOW LOADS: ASCE 7-10
GROUND SNOW LOAD, Pg = 60 PSF ROOF SNOW LOAD, Pf = 46 PSF
DRIFT & UNBALANCED LOADS APPLY
EXPOSURE FACTOR, Ce = 1.0 THERMAL FACTOR, Ct = 1.1
IMPORTANCE FACTOR, I = 1.0
4.1.3. WIND LOADS: ASCE 7-10
BASIC WIND SPEED = 115 MPH
BASED UPON RISK CATEGORY
IMPORTANCE FACTOR, I = 1.0
EXPOSURE = B
EXPOSURE FACTOR, Ce = 1.0
4.2. ROOF TRUSS LOADS
4.2.1. ROOF TOP CHORD DEAD LOAD = 10 PSF
4.2.2. ROOF BOTTOM CHORD DEAD LOAD = 10 PSF
5. STRUCTURAL - FOUNDATIONS
5.1. ALL FOUNDATIONS AND CONCRETE SLABS ON GRADE SHALL
BE PLACED ON WELL COMPACTED UNDISTURBED VIRGIN
SOIL OR APPROVED STRUCTURAL FILL AND IT SHALL BE 95%
PROCTOR DENSITY OR BETTER. REFER TO SPECIFICATIONS.
5.2. THE BOTTOM OF ALL FOOTINGS SHALL BE PLACED AT THE
REQUIRED FROST DEPTH (OR DEEPER), BASED UPON THE
GOVERNING CODE AND/OR LOCAL REQUIREMENTS,
WHETHER SPECIFICALLY SHOWN ON THE PLANS OR NOT. IF
THERE IS A DISCREPANCY BETWEEN THE PLANS AND THE
CODE REQUIREMENTS, THE CONTRACTOR SHALL
CONSTRUCT THE FOUNDATIONS PER THE CODE.
CONTRACTOR SHALL COMMUNICATE ALL DISCREPANCIES
WITH THE ENGINEER.
5.3. NO FOUNDATIONS SHALL BE PLACED ON FROZEN SOIL.
5.4. PROTECT IN-PLACE FOUNDATIONS AND SLABS ON GRADE
FROM FROST PENETRATIONS UNTIL PROJECT IS COMPLETE.
5.5. CONTRACTOR SHALL EMPLOY MEANS OF CONTROLLING
SURFACE AND SUBSURFACE GROUND WATER SO ALL
FOUNDATION WORK IS INSTALLED ON DRY SUBGRADE.
5.6. BACKFILL
5.6.1. BACKFILL FOUNDATION WALLS EQUALLY ON BOTH SIDES.
COMPACT AT EACH 12" LIFT.
6. STRUCTURAL - CONCRETE
6.1. CONCRETE WORK SHALL CONFORM TO THE LATEST
STANDARDS OF THE ACI-318 CODE.
6.2. CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE
STRENGTH OF:
6.2.1. SLABS-ON-GRADE (EXTERIOR) = 4000 PSI
6.2.2. SLABS-ON-GRADE (INTERIOR) = 4000 PSI
6.2.3. FOOTINGS = 3000 PSI
6.2.4. FOUNDATION WALLS & PIERS = 3500 PSI
6.3. ALL EXPOSED EXTERIOR CONCRETE SHALL BE
AIR-ENTRAINED.
6.4. ALL INTERIOR CONCRETE SLABS SHALL HAVE A 10 mil POLY
VAPOR BARRIER (MIN) BELOW THE SLAB.
6.5. PLACE EXPANSION JOINTS AS SHOWN ON DRAWINGS.
6.6. CUT SLAB CONTROL JOINTS WITH A DEPTH OF 1/3 OF SLAB
THICKNESS IN LOCATIONS SHOWN ON DRAWINGS. IF
LOCATIONS ARE NOT INDICATED ON DRAWINGS LOCATE
CONTROL JOINTS AT THE FOLLOWING SPACING:
CONTROL JOINT SPACING = MAXIMUM OF 36 TIMES THE
CONCRETE THICKNESS. LENGTH OF SLAB SHALL NOT
EXCEED 1 1/2 TIMES THE WIDTH.
7. STRUCTURAL - REINFORCEMENT
7.1. STEEL REINFORCING BARS SHALL CONFORM TO ASTM A615
- GRADE 60 (60,000 PSI)
7.2. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185
7.3. CLEARANCES (COVER) FOR REINFORCEMENT, UNLESS
NOTED OTHERWISE, SHALL BE:
7.3.1. CONCRETE PLACED ON EARTH OR CAST AGAINST EARTH
SHALL BE A MINIMUM OF = 3"
7.3.2. ALL OTHERS:
7.3.2.1.1. NO. 5 BAR AND LESS = 1 1/2"
7.3.2.1.2. NO. 6 BAR AND LARGER = 2"
7.4. LAP SPLICE BAR LENGTH = 48 X BAR DIA. UNLESS NOTED
OTHERWISE
8. STRUCTURAL - STEEL
8.1. STRUCTURAL STEEL WORK SHALL CONFORM TO THE
FOLLOWING:
8.1.1. AISC - "DETAILING FOR STEEL CONSTRUCTION".
8.2. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING:
8.2.1. ANCHOR BOLTS, ASTM A307 OR A36.
8.3. PROVIDE 2 MIL. THICK RED OR GREY OXIDE PRIMER ON ALL
STEEL SURFACES UNLESS NOTED OTHERWISE.
8.4. ANCHOR BOLTS SHALL BE PRESET WITH TEMPLATES AT
REQUIRED LOCATIONS.
8.5. LEVELING PLATES AND BEARING PLATES SHALL BE SET IN A
FULL BED OF NON-SHRINK GROUT.
8.6. CONTRACTOR SHALL FIELD TOUCH UP ALL ABRASIONS,
BURNS AND SIMILAR DEFECTS IN PAINT OF THE
STRUCTURAL STEEL.
9. STRUCTURAL - WOOD FRAMING
9.1. ALL LUMBER, UNLESS NOTED OTHERWISE, SHALL BE S4S #2
SPF OR BETTER.
9.2. DO NOT NOTCH, CUT OR BORE HOLES (LARGER THAN 3/4") IN
WOOD MEMBERS.
9.3. PLYWOOD SHALL BE LAID WITH FACE GRAIN
PERPENDICULAR TO SUPPORTS.
9.4. STAGGER PLYWOOD (OSB) JOINTS.
9.5. NAILING SHALL BE PER THE NAILING SCHEDULE OF THE
MOST CURRENT APPLICABLE CODE, UNLESS NOTED
OTHERWISE.
9.6. PRESSURE TREATED LUMBER SHALL BE TREATED WITH
CHROMATED COPPER ARSENATE TO A RETENTION LEVEL
OF .60 LBS. PER CUBIC FOOT.
9.7. PROVIDE PRESSURE TREATED LUMBER AT THE FOLLOWING
LOCATIONS:
9.7.1. WOOD EMBEDDED IN THE GROUND.
9.7.2. WOOD COMPONENTS IN CONTACT WITH CONCRETE OR
MASONRY.
9.8. ALL METALS AND/OR FASTENERS IN CONTACT WITH
PRESSURE TREATED WOOD SHALL BE TREATED AS
REQUIRED FOR THE TYPE OF WOOD TREATMENT USED
(GALVANIZED AND/OR STAINLESS STEEL) TO PREVENT
ACCELERATED CORROSION.
9.9. UTILIZE JOIST HANGER FASTENERS AS SUPPLIED AND/OR
REQUIRED BY THE JOIST HANGER MANUFACTURER.
9.10. ALL MANUFACTURED TRUSSES AND/OR ENGINEERED WOOD
PRODUCTS SHALL HAVE SHOP DRAWINGS SUBMITTED TO
THE OFFICE OF THE ENGINEER FOR REVIEW AND
APPROVAL. DRAWINGS SHALL SHOW SIZE, SPECIES AND
GRADE OF LUMBER, SIZE AND LOCATION OF CONNECTORS
AND BE SEALED BY AN ENGINEER REGISTERED IN THE
STATE OF MICHIGAN. TRUSS MANUFACTURER SHALL
DESIGN/SUPPLY ALL MECHANICAL CONNECTIONS (UNLESS
NOTED OTHERWISE) TO PROVIDE A COMPLETE ROOF
FRAMING ASSEMBLY. TRUSS MANUFACTURER SHALL
DESIGN/SUPPLY ALL BEARING ENHANCERS, AS REQUIRED.
TRUSS MANUFACTURER SHALL DESIGN THE TRUSSES PER
THE CURRENT CODE REQUIREMENTS, WHETHER
SPECIFICALLY STATED IN THESE PLANS OR NOT. IF
CONTRADICTIONS EXIST IN RELATION TO THE CODE DESIGN
REQUIREMENTS, TRUSS SUPPLIER SHALL UTILIZE THE
CURRENT CODE REQUIREMENTS AND CONTACT THE
ENGINEER TO REPORT THE CONTRADICTION, PRIOR TO THE
BID DUE DATE (IF APPLICABLE) AND/OR BEFORE TRUSSES
ARE FABRICATED. CONTRACTOR SHALL VERIFY ALL
AS-BUILT DIMENSIONS PRIOR TO ORDERING TRUSSES
AND/OR ENGINEERED WOOD PRODUCTS.
10. ARCHITECTURAL
10.1. EXTERIOR DIMENSIONS ARE TO THE OUTSIDE FACE OF THE
NEW FRAMING OR MASONRY OR CONCRETE. INTERIOR
DIMENSIONS ARE TO THE FACE OF THE NEW FRAMING OR
MASONRY OR CONCRETE.
10.2. ALL INTERIOR AND EXTERIOR SURFACES EXPOSED TO VIEW
AND NOT RECEIVING A FINISHED MATERIAL, UNLESS
OTHERWISE INDICATED, SHALL BE FINISHED (PAINTED OR
STAINED).
10.3. WHERE APPLICABLE, PAINT ELECTRIC SERVICE PIPING,
WATER SERVICE PIPING AND GAS METER AT EXTERIOR TO
MATCH ADJACENT FINISH MATERIAL.
10.4. PRODUCTS NOT TO BE FINISHED (PAINTED OR STAINED),
UNLESS OTHERWISE NOTED:
10.4.13. ITEMS SPECIFIED OR PROVIDED WITH FACTORY FINISH;
MATERIALS AND PRODUCTS HAVING FACTORY-APPLIED
PRIMERS ARE NOT CONSIDERED FACTORY FINISHED.
10.4.14. ITEMS INDICATED TO RECEIVE OTHER FINISHES.
10.4.15. ITEMS INDICATED TO REMAIN UNFINISHED.
10.4.16. MARBLE, GRANITE, SLATE, AND OTHER NATURAL
STONES.
10.4.17. BRICK, CONCRETE, CAST STONE, INTEGRALLY COLORED
PLASTER.
10.4.18. CONCRETE OR MASONRY IN UTILITY, MECHANICAL, AND
ELECTRICAL SPACES.
10.4.19. STAINLESS STEEL, ANODIZED ALUMINUM, BRONZE, AND
LEAD.
10.4.20. EQUIPMENT NAMEPLATES, FIRE RATING LABELS, AND
OPERATING PARTS OF EQUIPMENT.
10.4.21. ACOUSTICAL MATERIALS.
10.4.22. CONCEALED PIPES, DUCTS, AND CONDUITS.
NOTES & GENERAL NOTES
# POUND OR NUMBER
& AND
@ AT
% PERCENT
AB ANCHOR BOLT
ACT ACOUSTICAL CEILING TILE
AFF ABOVE FINISHED FLOOR
N.F.A. NET FREE AREA
ALUM. ALUMINUM
APPROX. APPROXIMATE
A/C AIR CONDITIONING
BIT. BITUMINOUS
BO BY OWNER
BOT. BOTTOM
BSMT. BASEMENT
BY OWNER SUPPLIED BY OWNER, INSTALLED BY CONTRACTOR
B/W BETWEEN
CAB. CABINET
CB CATCH BASIN
CJ CONTROL JOINT
CJP COMPLETE JOINT PENETRATION
CL CENTERLINE OR CLOSET
CLG. CEILING
CLR. CLEAR
CMU CONCRETE MASONRY UNIT
COL. COLUMN
CONC. CONCRETE
CONT. CONTINUOUS
CTV CONTRACTOR TO VERIFY
DA DOOR ACTUATOR
DBL. DOUBLE
DEMO. DEMOLISH OR DEMOLITION
DF DRINKING FOUNTAIN
DIA. DIAMETER
DIM. DIMENSION
DIMS. DIMENSIONS
DN. DOWN
DR. DOOR
DT DRAIN TILE
DWG. DRAWING
EA. EACH
EJ EXPANSION JOINT
EL. ELEVATION
ELEC. ELECTRICAL
ELEV. ELEVATOR
EQ. EQUAL
EW EACH WAY
EXIST. EXISTING
EXP. EXPANSION
EXT. EXTERIOR
FB FACE BRICK
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER & CABINET
FIN. FINISH
FLR. FLOOR
FND. FOUNDATION
FO FACE OF
FTG. FOOTING
GA. GAUGE
GALV. GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GEN. GENERAL
GND. GROUND
GYPBD. GYPSUM WALL BOARD
HB HOSE BIB
HDR. HEADER
HPDL HIGH PRESSURE DECORATIVE LAMINATE
HM HOLLOW METAL
HR. HOUR
INSUL. INSULATED OR INSULATION
INT. INTERIOR
INV. INVERT
JAN. JANITOR
KIP KILOPOUND (1000 POUNDS)
LAV. LAVATORY
LL LIVE LOAD
LNDG. LANDING
MAX. MAXIMUM
M.E.A. MATCH EXISTING
MECH. MECHANICAL
MEZZ. MEZZANINE
MIN. MINIMUM
MIR. MIRROR
MISC. MISCELLANEOUS
MO MASONRY OPENING
MTD. MOUNTED
MTL. METAL
NFA NET FREE AREA
N.I.C. NOT IN CONTRACT = (SUPPLIED BY OWNER INSTALLED BY OWNER)
NOM. NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OH. OVERHEAD
PJP PARTIAL JOINT PENETRATION
P.LAM. PLASTIC LAMINATE
PLF POUNDS PER LINEAL FOOT
PLUMB. PLUMBING
PLYWD. PLYWOOD
PR PAIR
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PVC POLYVINYL CHLORIDE
RAD. RADIUS
RD ROOF DRAIN
REBAR. REINFORCING BAR
REFRIG. REFRIGERATOR
REINF. REINFORCEMENT OR REINFORCE
REQD. REQUIRED
RM. ROOM
ROW RIGHT OF WAY
SAN. SANITARY
SCHED. SCHEDULE
SF SQUARE FOOT
SHTHG. SHEATHING
SHWR. SHOWER
SIM. SIMILAR
SPEC. SPECIFIED OR SPECIFICATION
SSTL. STAINLESS STEEL
STD. STANDARD
STL. STEEL
STOR. STORAGE
STRUCT. STRUCTURE OR STRUCTURAL
SUSP. SUSPENDED
TD TRENCH DRAIN
T/D TELEPHONE/DATA
T&G TONGUE AND GROOVE
TELE. TELEPHONE
THK. THICK, THICKNESS
THRU THROUGH
TLT. TOILET
T.O. TOP OF
TOC TOP OF CONCRETE
TOS TOP OF STEEL
TP TOILET PAPER DISPENSER
TYP. TYPICAL
UNO UNLESS NOTED OTHERWISE
U.G. UNDERGROUND
UR. URINAL
VERT. VERTICAL
VEST. VESTIBULE
W/ WITH
W/O WITHOUT
WC. WATERCLOSET
WD. WOOD
WH. WATER HEATER
WPT. WORKING POINT
WT. WEIGHT
WWF WELDED WIRE FABRIC
A1.1
X X
X X
100'-0"
FIN. FLOOR
A
A
REFER TO WINDOW SCHEDULE OR
ENLARGE WINDOW ELEVATION
REFER TO DOOR SCHEDULE
SECTION CALLOUT
INTERIOR ELEVATION
DETAIL BLOWUP
ROOM NAME
ROOM NAME
DETAIL NUMBER
SHEET NUMBER TO REFERENCE
FOR DETAIL BLOWUP
SECTION NUMBER
SHEET NUMBER TO REFERENCE
FOR SECTION
DOOR NUMBER
WINDOW TYPE NUMBER
ELEVATION NUMBER
SHEET NUMBER TO REFERENCE
FOR INTERIOR ELEVATION
A1.1
DETAIL CALLOUT
DETAIL NUMBER
SHEET NUMBER TO REFERENCE
FOR DETAIL
DRAWING SYMBOLS KEY
ROOM TAG/NAME
ROOM NAME
ROOM NUMBER
DOOR TAG
REFER TO ROOM SCHEDULE
WINDOW TAG
COLUMN GRID LINE
ELEVATION TAG
LOCATION REFERENCE
ELEVATION
KEY NOTE TAG
REFERENCE NUMBER
REFER TO KEY NOTE SCHEDULE
Z:
\0
0- D
W G
\0 0-
E sc an ab a Ar ea P ub lic
S ch oo ls
\2 2-
H ig h Sc ho ol
A th le tic
B at hr oo m B ui ld in g, E sc an ab a, M
I\2 2-
_0 1_
G
2_
AB
BR
EV
A N
D S
TD
D
ET
a nd A
D A.
dw g
/3 1/
0:
:0
AM
R E
V
IS
IO
N
D A
TE
Date
Drawn By
Checked By
Job No.
P ro je ct
T itl e
Dynamic Design Group, inc.
900 1st Ave. So., Ste. A
Escanaba, MI ph.: 906.786.3300 email: gen@ddgi-ddm.com www.ddgi-ddm.com
M d d
COPYRIGHT 2020 DYNAMIC
DESIGN GROUP, INC., ESCANABA, MI.
This document is not to be used, copied or reproduced without expressed written permission from Dynamic Design Group, inc.
F O
R R
E V
IE
W
/F O
R C
O N
S T
R U
C T
IO
N
ES
C
A N
A B
A , M
IC
H
IG
A
N
ES
C
A N
A B
A A
R
EA
P U
B
LI
C S
C H
O O
LS
H
IG
H
S C
H O
O L
A
TH
LE
TI
C R
ES
TR
O O
M B
U
IL
D
IN
G
03-31-2025
22-4520
G0.2
DSB
8"
2' -3
9"
11" MIN.
" M
IN
" M
AX
9"
LATCH SIDE
OF DOOR.
DIMENSION TO
DOOR JAMB
9" -1
2"
6" - 8"
TEXT 5/8"
TO 1"
SIGN SHALL CONFORM TO THE CURRENT CODE,
INCLUDING THE ACCESSIBILITY CODE'S ADOPTED BY THE
STATE IN WHICH THE PROJECT IS LOCATED. CODES SHALL
INCLUDE BUT NOT BE LIMITED TO, ICC A117.1 AND ADA.
1'-0"3'-6"
3'-4"
2' -1
0"3' -4
1'
-6
6" 3'-0"
2' -1
0"
1/
2" M
IN
. V
ER
IF
Y
18"
16" MIN.
2X6 BLOCKING
5'-0" CLR. OTHER FIXTURE NOT
ALLOWED IN THIS AREA
5'-0" CLR. OTHER FIXTURE NOT
ALLOWED IN THIS AREA
GB-18
GB-42
GB-36
2X6 BLOCKINGWC
M
IN
5" 8"
TOILET PAPER DISPENSER (TTD) MOUNTING LOCATION
2X6 BLOCKING
TTD
GRAB BAR (GB) MOUNTING LOCATIONSGRAB BAR (GB) MOUNTING LOCATIONS
3' -4
" M
AX
TO
L
O W
ER
E
D G
E O
F R
EF
LE
C
TI
VE
SU
R
FA
C E
MIRROR (MIR) MOUNTING DETAIL
MIR
2' -1
0" M
AX
1'-3" MIN.
LAVITORY MOUNTING DETAIL
LAVATORY CLEAR SPACE DETAIL
NOTES:
1. REQUIRED ACCESSIBLE TOILET FACILITIES SHALL COMPLY WITH THE CURRENT MICHIGAN BARRIER FREE
CODE, ICC/ANSI-A 117.1 AND THE MICHIGAN PLUMBING CODE.
2. PROVIDE BARRIER FREE ACCESSIBLE TOILET ROOM FOR MEN AND WOMEN WITH A 32" MINIMUM CLEAR DOOR
OPENINGS.
3. WATER CLOSET MUST BE LOCATED 18" TO THE CENTERLINE FROM THE ADJACENT WALL/PARTITION. THE
SEAT MUST BE 17" A.F.F. AND FLUSH CONTROLS NOT HIGHER THAN 36" A.F.F.
4. MAXIMUM WATER TEMPERATURE AT HAND SINKS SHALL NOT EXCEED 110 DEGREES FAHRENHEIT. FAUCETS
SHALL BE ADA LEVER OR PUSH-BUTTON TYPE. EXPOSED WATER AND DRAIN LINES SHALL BE INSULATED.
5. TOILET ROOM ACCESSORIES SHALL BE MOUNTED WITH THE CONTROLS NO MORE THAN 48" A.F.F.. MIRRORS
SHALL BE INSTALLED NO MORE THAN 40" A.F.F..
6. PROVIDE SIGNS SHOWING GENDER AND THE INTERNATIONAL SYMBOL FOR THE HANDICAPPED ON THE
EXTERIOR OF THE ROOM. INSTALL ADJACENT TO THE LATCH SIDE OF THE DOOR.
7. WATER CLOSET TYPE, FIXTURE TYPE AND ACCESSORIES ARE SHOWN FOR REFERENCE ONLY. SEE RELATED
DRAWINGS AND/OR SPECIFICATIONS FOR SPECIFIED WATER CLOSET, FIXTURES AND ACCESSORIES
SCHEDULED FOR INSTALLATION.
8. 2X6 BLOCKING SHOWN IS TO BE INSTALLED ON WOOD STUD FRAMED WALLS ONLY. SEE PLANS FOR SPECIFIC
WALL TYPE SCHEDULED.
9. GRAB BAR MOUNTING LOC. GB-18 & GB-42 REQUIRED ON EA. SIDE OF TLT. IN AMBULATORY COMPARTMENTS.
PIPE PROTECTION
REQUIRED
3' -8
" M
AX
T O
O
PE
R
AT
IN
G
D
EV
IC
E
O R
T O
D
IS
C H
AR
G
E O
N A
U
TO
S
EN
SI
N
G U
N
IT
S
HAND DRYER MOUNTING DETAIL
Scale: NTS BARRIER FREE TYPICAL DETAILGB2 Scale: NTS
BARRIER FREE TYPICAL DETAILGB1 Scale: NTS BARRIER FREE TYPICAL DETAILTP Scale: NTS
BARRIER FREE TYPICAL DETAILMR Scale: NTS BARRIER FREE TYPICAL DETAILLV2 Scale: NTS
BARRIER FREE TYPICAL DETAILLV1
Scale: NTS
BARRIER FREE TYPICAL DETAILHD
TLT. RM. ACCESSORY SCHEDULE
GB-42
MARK TYPE
42" GRAB BAR
REMARKS
GB-36 36" GRAB BAR
TTD TOILET PAPER DISPENSER
WC WATER CLOSET
LAV WALL HUNG LAVATORY
NOTES:
1. MOUNT ALL ITEMS AT THEIR RECOMMENDED ADA MOUNTING
HEIGHTS. SEE TYPICAL MOUNTING HEIGHT DETAIL ON THIS
SHEET.
2. GRAB BAR DIAMETER SHALL BE 1 1/2" O.D. THE SPACE
BETWEEN THE WALL AND GRAB BAR SHALL BE 1 1/2".
3. BY OWNER MEANS PROVIDED BY OWNER, INSTALLED BY
CONTRACTOR.
4. ELECTRIC HAND DRYER - XLERATOR® Hand Dryer, HANDS FREE
(NO BUTTON), COLOR AS SELECTED BY OWNER.
5. ACCESSORY SPECIFICATIONS:
5.1. GENERAL:
5.1.1. MFGR: BRADLEY, BOBRICK OR APPROVED EQUAL.
5.1.2. FASTENERS - TAMPER PROOF STAINLESS STEEL.
FASTENERS SHALL BE APPROPRIATE FOR
SUBSTRATE AND AS RECOMMENDED BY MFGR.
5.2. ACCESSORIES
5.2.1. GRAB BARS (GB) - 1.5 O.D., MODEL 812, STAINLESS
STEEL, SAFETY-GRIP TYPE WITH CONCEALED
MOUNTING.
5.2.2. MIRROR (MIR1) - MODEL 781 - FRAMED, CONCEALED
FASTENERS, NO. 8 STAINLESS STEEL FINISH.
UR WALL HUNG URINAL
MIR 36h" x 18w" MIRROR, MIN. SIZE
EHD ELECTRIC HAND DRYER SEE NOTES BELOW
SEE PLUMB. DWGS
SEE PLUMB. DWGS
SEE PLUMB. DWGS
GB-18 18" GRAB BAR
Scale: NTS
SIGNAGE DETAILSI
FINISHED FLR.
WALL HUNG
UNIT
" N
TS
Scale: NTS
FIRE EXTINGUISER MOUNTING DET.FE
1'-6"
MIN
IF LOCATED ADJACENT
TO A DOOR. (SEE PLAN
FOR LOCATION)
UR
" M
AX
13 1/2"
MIN.
15" CLR.15" CLR.
URINAL (UR) MOUNTING DETAIL
Scale: NTS
BARRIER FREE TYPICAL DETAILU
2' -6
3/
"ELEVATION
Scale: NTS
BABY CHANGING STATION DET.BC
MFGR.: KOALA KARE
MODEL NO.: KB300
MOUNTING: SURFACE - HORIZONTAL
FIRE EXTINGUISHER NOTES:
- FIRE EXTINGUISHER SHALL BE ANY DRY
CHEMICAL, TYPE A B C, EXTINGUISHER
WITH A 2A RATING.
Scale: NTS
DRINKING FOUNTAIN TYPICAL DETAILDF
" S
TA
N
D
AR
D
" M
AX
A
D A
" M
IN
C
LE
AR
AD
A
BY OWNER
SN SANITARY NAPKIN DISPOSAL
Z:
\0
0- D
W G
\0 0-
E sc an ab a Ar ea P ub lic
S ch oo ls
\2 2-
H ig h Sc ho ol
A th le tic
B at hr oo m B ui ld in g, E sc an ab a, M
I\2 2-
_0 1_
G
2_
AB
BR
EV
A N
D S
TD
D
ET
a nd A
D A.
dw g
/3 1/
0:
:1
AM
R E
V
IS
IO
N
D A
TE
Date
Drawn By
Checked By
Job No.
P ro je ct
T itl e
Dynamic Design Group, inc.
900 1st Ave. So., Ste. A
Escanaba, MI ph.: 906.786.3300 email: gen@ddgi-ddm.com www.ddgi-ddm.com
M d d
COPYRIGHT 2020 DYNAMIC
DESIGN GROUP, INC., ESCANABA, MI.
This document is not to be used, copied or reproduced without expressed written permission from Dynamic Design Group, inc.
F O
R R
E V
IE
W
/F O
R C
O N
S T
R U
C T
IO
N
ES
C
A N
A B
A , M
IC
H
IG
A
N
ES
C
A N
A B
A A
R
EA
P U
B
LI
C S
C H
O O
LS
H
IG
H
S C
H O
O L
A
TH
LE
TI
C R
ES
TR
O O
M B
U
IL
D
IN
G
03-31-2025
22-4520
G0.3
UCABL
UCABL
UCABL
UCABL
UCABL
UCABL
UCABL
UCABL
UCABL
UCABL
UCABL
UCABL
UCABL
UCABL
UCABL
UCABL
UCABL
MH
MH
STORM
STORM
STORM
STORM
STORM
STORM
STORM
STORM
STORM
STORM
STORM
STORM
STORM
STORM
STORM
STORM
STORM
STORM
STORM
STORM
MH
STO
R
M
STO
R M
STO
R
M
STO
R M
STO
R
M
STO
R M
STO
R
M
STO
R M
STO
R
M
STO
R M
STO
R
M
STO
R M
STO
R
M
STO
R M
STO
R
M
STO
R M
STO
R
M
STO
R M
STO
R
M
STO
R M
STO
R
M
C O
N C
W A
LK
ASPHALT WALK
RIM 610.58'
RIM 611.67'
RIM 611.52'
RIM 610.92'
IN
V 604.28'
INV 604.18'
INV 606.35'
INV 607.23'
INV 605.39'
INV 602.82'
INV 602.22'
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
UE
U E
SCALE: 1"= 40'
INDICATES A LIGHT / POLE
Escanaba, Michigan 49829 Phone (906)786-1755,INDICATES A WATERMAIN
DATE OF MAPPING
JOB NUMBER
DATE OF SURVEY
SURVEY FOR
L A N D S U R V E Y O R S, P. C.
21482-21J HIGH SCHOOL TOPO
DYNAMIC DESIGN
HYD
MH
UNDERGROUND GAS LINE
SUBJECTGUY WIRE
OCTOBER 19, 2021
OCTOBER 20, 2021
INDICATES A WATER VAVLE
INDICATES A CATCH BASIN
INDICATES A HYDRANT
INDICATES A UTILITY POLE
UNDERGROUND POWER
UNDERGROUND TELEPHONE
OVERHEAD POWER / CABLE
SANITARY SEWER LINE
1410 Ludington Street
INDICATES A MAN HOLE
Fax 786-6487
TOPOGRAPHIC SURVEY
INDICATES A CHISLED CROSS IN CONCRETE
LEGEND
T
IRON MONUMENTS FOUND
INDICATES A TELEPHONE JUNCTION BOX
IRON MONUMENTS SET
STORM LINE
INDICATES A LINE NOT DRAWN TO SCALE
City of Escanaba Delta County, Michigan
Part of of SE1/4 of SE1/4 Section 25 T.39N., R.23W.
Escanaba Senior High School
AS
H
PA
LT
T R
AC
K
B
LE
EC
H
ER
S
C O
N C
WALK
SHED
20" MAPLE
SHRUB
5" ELM8" ELM 3" ELM
CONC.
STEP
AS
H
PA
LT
T R
AC
K
INDICATES VARIOUS SIGNS
SPIGOT
SPIGOT
SPIGOT
CO
N
C.
W
AL
K
CONC. WALK
CONC. APRIN
TE
NNIS COURTS
5TH AVENUE SOUTH
(70' R/W)
PA
RKING LO
T
STOP
C O
N C
W
AL
K
TOP OF DOME 611.54'
FO FO FO
FO FO
FO FO
FO FO
FO FO
FO FO
FO FO FO
FO FO
FO FO
SUPPORT POST EMBEDDED 20"
NOTE: A 8'-0" POST SPACING
ALLOWED IF A WOVEN GEOTEXTILE
FABRIC IS USED.
3'-0"MAX.
3'-0"MAX.
3'-0"MAX.
3'-0"MAX.
2' -0
GEOTEXTILE FABRIC ONLY
BACKFILL & COMPACT TRENCH WITH
EXCAVATED SOIL
NOTE: ADDITIONAL POST DEPTH OR TIE
BACKS MAY BE REQUIRED IN
UNSTABLE SOILS
FLOW DIRECTION
NOTE: TRENCH SHALL BE A MIN. OF 4"
WIDE & 6" DEEP TO BURY & ANCHOR
THE GEOTEXTILE FABRIC, FOLD
MATERIAL TO FIT TRENCH & BACKFILL
& COMPACT TRENCH WITH
EXCAVATED SOIL.
UPSLOPE SIDE DOWNSLOPE SIDE
SECTION A-A
WOOD OR STEEL
SUPPORT POSTS AS
SPECIFIED IN NR 1056
GEOTEXTILE FABRIC. ATTACH IN
AT LEAST 3 PLACES ON UPSLOPE
SIDE.
SUPPORT
CORD
FLOW
FOLD
FABRIC 3"
MAX.
A
A
1' -3
21 4"
Z:
\0
0- D
W G
\0 0-
E sc an ab a Ar ea P ub lic
S ch oo ls
\2 2-
H ig h Sc ho ol
A th le tic
B at hr oo m B ui ld in g, E sc an ab a, M
I\2 2-
_C iv il.
dw g
/3
1/
0:
:1
AM
R E
V
IS
IO
N
D A
TE
Date
Drawn By
Checked By
Job No.
P ro je ct
T itl e
Dynamic Design Group, inc.
900 1st Ave. So., Ste. A
Escanaba, MI ph.: 906.786.3300 email: gen@ddgi-ddm.com www.ddgi-ddm.com
M d d
COPYRIGHT 2020 DYNAMIC
DESIGN GROUP, INC., ESCANABA, MI.
This document is not to be used, copied or reproduced without expressed written permission from Dynamic Design Group, inc.
F O
R R
E V
IE
W
/F O
R C
O N
S T
R U
C T
IO
N
ES
C
A N
A B
A , M
IC
H
IG
A
N
ES
C
A N
A B
A A
R
EA
P U
B
LI
C S
C H
O O
LS
H
IG
H
S C
H O
O L
A
TH
LE
TI
C R
ES
TR
O O
M B
U
IL
D
IN
G
03-31-2025
22-4520 Scale: 1"=80'
SURVEY1
EROSION CONTROL NOTES
1. DESIGN CRITERIA, STANDARDS AND SPECIFICATIONS FOR CONTROL MEASURES SHALL COMPLY WITH THE DEPARTMENT OF NATURAL RESOURCE'S CONSTRUCTION SITE EROSION AND SEDIMENT CONTROL "TECHNICAL
STANDARDS" AND THE REQUIREMENTS SET BY FEDERAL, STATE, AND LOCAL AUTHORITIES.
2. THE SITE CONTRACTOR SHALL INSTALL AND MAINTAIN ALL EROSION CONTROL ELEMENTS IN ACCORDANCE
WITH ALL GOVERNING AUTHORITY'S REGULATIONS.
3. CONTRACTOR IS RESPONSIBLE FOR PERFORMING STANDARD MEASURES FOR SOIL EROSION AND SEDIMENT CONTROL AS REQUIRED BY CODE AND LOCAL ORDINANCES PRIOR TO PERFORMING ANY EXCAVATION.
SECURE ANY STOCK PILES TO PREVENT SEDIMENT RUN OFF.
4. ALL ACTIVITIES ON THE SITE SHALL BE CONDUCTED IN A LOGICAL SEQUENCE TO MINIMIZE THE AREA OF SOIL EXPOSED AT ONE TIME. THIS SHALL INCLUDE THE PLANTING OF VEGETATION WITHIN 7 DAYS OF LAND
DISTURBANCE.
5. ALL EROSION CONTROL ELEMENTS SHALL REMAIN IN PLACE UNTlL A SUFFICIENT GROWTH OF GRASS IS ESTABLISHED IN ALL GENERAL LANDSCAPED AREAS, AND THEN REMOVED BY THE SITE CONTRACTOR.
6. THE CONTRACTOR SHALL INSPECT ALL EROSION CONTROL MEASURES WEEKLY AND WITHIN 24 HOURS AFTER ANY RAINFALL OF 0.5" OR MORE AND MAKE REQUIRED REPAIRS. IF STRAW BALES ARE USED AS CONTROL MEASURES, THEY SHALL BE REPLACED NOT LESS THAN EVERY 90 DAYS OR MORE FREQUENTLY IF
DETERMINED TO BE NON-EFFECTIVE BY THE LOCAL AUTHORITY.
7. SILT FENCES IN COMPLIANCE WITH CODE REQUIREMENTS SHALL BE PLACED AT 35 FOOT INTERVALS ALONG ALL SIDE SLOPE AND DOWN SLOPE AREAS OF THE SITE PRIOR TO DISTURBING THE UP SLOPE AREA ON THE
SITE.
8. ANY SOIL STOCKPILES WHICH ARE LEFT INACTIVE MORE THAN 7 DAYS MUST BE PROTECTED BY SEEDING & MULCHING, EROSION MAT, SILT FENCING, COVERING OR OTHER APPROVED METHODS. THE CONTRACTOR WILL BE RESPONSIBLE FOR PLACEMENT LOCATION OF TEMPORARY STOCKPILES AND MUST IMPLEMENT ONE
OF THE APPROVED METHODS TO PREVENT ANY EROSION.
9. DISTURBED GROUND OUTSIDE OF THE EVERYDAY CONSTRUCTION AREA, INCLUDlNG SOIL STOCKPlLES LEFT
INACTIVE FOR MORE THAN 10 DAYS, SHALL AT A MINIMUM BE TEMPORARILY STABILIZED BY
SEEDING/MULCHING OR OTHER METHODS APPROVED BY THE LOCAL... GOVERNING AUTHORITY'S EROSION
CONTROL INSPECTOR
10. ALL OFF SITE SEDIMENT DEPOSITS OCCURRING AS A RESULT OF CONSTRUCTION WORK OR A STORM EVENT
SHALL BE CLEANED UP BY THE END OF EACH DAY. FLUSHING SHALL NOT BE ALLOWED.
11. ALL SEDIMENT DEPOSITS OCCURRING AS A RESULT OF CONSTRUCTION ACTIVITIES, INCLUDING SOIL TRACKED BY CONSTRUCTION TRAFFIC ONTO ADJACENT STREETS, SHALL BE REMOVED BY USE OF MECHANICAL OR MANUAL SWEEPING OPERATIONS (NOT FLUSHING), BY THE END OF EACH WORK DAY. EXCESSIVE AMOUNTS OF SEDIMENT OR OTHER DEBRIS TRACKED ONTO ADJACENT STREETS SHALL BE CLEANED IMMEDIATELY.
12. ALL SEDIMENT LADEN WATER PUMPED FROM THE SITE SHALL BE TREATED BY A TEMPORARY SEDIMENT BASIN OR BE FILTERED BY OTHER APPROVED MEANS. WATER SHALL NOT BE DISCHARGED IN A MANNER THAT
CAUSES EROSION OF THE SITE OR RECEIVING CHANNELS.
13. STORM INLET PROTECTION BARRIERS SHOULD BE IN COMPLIANCE WITH CODE REQUIREMENTS. APPROVED INLET PROTECTION SHALL BE INSTALLED ONCE THE DRAIN, DROP, OR CURB INLET CAN RECEIVE RUNOFF. THE DEVICE SHALL REMAIN IN PLACE AND BE MAINTAINED UNTIL THE DISTURBED AREA IS STABILIZED.
14. ANY WASTE AND MATERIAL DISPOSAL SHALL BE PROPERLY DISPOSED OF AND NOT ALLOWED TO RUN INTO
RECEIVING WATER OR STORM SEWER SYSTEM.
15. EROSION CONTROL DEVICES DESTROYED AS A RESULT OF CONSTRUCTION ACTIVITIES SHALL BE REPLACED
BY THE END OF THE WORK DAY.
16. THE CONTRACTOR SHALL WATER UNTIL THE SURFACE IS WET & REPEAT AS NEEDED TO LIMIT AIRBORNE DUST ON THE SITE. WATER SHALL BE APPLIED AT LIMITED RATES SO THAT RUNOFF DOES NOT OCCUR.
17. TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED AFTER STABILIZATION OF DISTURBED SOIL
(70% PERENNIAL VEGETATION COVER) HAS OCCURRED.
18. DITCHES SHALL BE TOPSOILED, SEEDED, FERTILIZED AND MULCHED.
Scale: 1"=1'-0"
SILT FENCE DETAILSFD
C1.0
DSB
DSB
N.T.S.
1960 SOIL TEST HOLE DATA FOR AREAS AROUND THE ENTIRE BUILDING - FOR INFORMATION ONLY2
STORM MANHOLE
RIM EL 610.58'
PIPE INV EL 604.28'
PIPE INV EL 604.18' SANITARY MANHOLE
RIM EL 611.67'
PIPE INV EL 607.23'
PIPE INV EL 606.35'STORM MANHOLE
JUNIOR/SENIOR
HIGH SCHOOL
BUILDING
MH
SPIGOT
BL
EA
C H
ER
S
CONCRETE
STEPS/SLAB
SHED
TR
AC
K
20" MAPLE
EXISTING TENNIS COURTS
SHRUB
STORM MANHOLE
RIM EL 610.58'
PIPE INV EL 604.28'
PIPE INV EL 604.18'
SANITARY MANHOLE
RIM EL 611.67'
PIPE INV EL 607.23'
PIPE INV EL 606.35'
8" ELM 5" ELM 3" ELM
STORM MANHOLE
RIM EL 610.92'
PIPE INV EL 602.22'
PIPE INV EL 602.82'
STOP SIGN
5TH AVENUE SOUTH (70FT R/W)
SANITARY MANHOLE
RIM EL 611.52'
PIPE INV EL 605.39'
SOUTH PARKING LOT
1" OR 2" BURIED
PLASTIC WATER LINE
SPIGOT
1 1/4" BURIED
PLASTIC WATER LINE
SPIGOT
SANITARY MANHOLE
BURIED 2FT BELOW GRADE
RIM EL 611.147'
PIPE INV EL 595.55'
(APPROXIMATELY 10FT
INTO WATER TABLE)
8" CONCRETE
SANITARY PIPE
STORM MANHOLE
JUNIOR/SENIOR
HIGH SCHOOL
BUILDING
LOCATION OF CONDUIT BELOW THE
EXISTING STORM PIPE, FOR NEW
WATER SERVICE. SEE NOTE 2
DEMO:
EXISTING CONCRETE WALK
FOR NEW UTILITIES.
PROTECT EXISTING UTILITIES
LOCATION OF CONDUIT ABOVE THE
EXISTING STORM PIPE, FOR NEW
ELECTRIC SERVICE. SEE NOTE 2
EXISTING TENNIS COURTS
EXISTING
PAVILLION
SPIGOT
Z:
\0
0- D
W G
\0 0-
E sc an ab a Ar ea P ub lic
S ch oo ls
\2 2-
H ig h Sc ho ol
A th le tic
B at hr oo m B ui ld in g, E sc an ab a, M
I\2 2-
_C iv il.
dw g
/3
1/
0:
:2
AM
R E
V
IS
IO
N
D A
TE
Date
Drawn By
Checked By
Job No.
P ro je ct
T itl e
Dynamic Design Group, inc.
900 1st Ave. So., Ste. A
Escanaba, MI ph.: 906.786.3300 email: gen@ddgi-ddm.com www.ddgi-ddm.com
M d d
COPYRIGHT 2020 DYNAMIC
DESIGN GROUP, INC., ESCANABA, MI.
This document is not to be used, copied or reproduced without expressed written permission from Dynamic Design Group, inc.
F O
R R
E V
IE
W
/F O
R C
O N
S T
R U
C T
IO
N
ES
C
A N
A B
A , M
IC
H
IG
A
N
ES
C
A N
A B
A A
R
EA
P U
B
LI
C S
C H
O O
LS
H
IG
H
S C
H O
O L
A
TH
LE
TI
C R
ES
TR
O O
M B
U
IL
D
IN
G
03-31-2025
22-4520Scale: 1"=40' EXISTING SITE/UTILITY/DEMO PLAN1Scale: 1"=40'
EXISTING GRADES/CONTOURS PLAN1
CIVIL KEY - EXISTING
EXISTING CONCRETE
EXISTING ASPHALT
EXISTING GRASS
ALL EXISTING GRASS AREAS AFFECTED
BY WORK TO BE REPAIRED WITH
TOPSOIL, SEEDED AND MULCHED
EXISTING UNDERGROUND STORM
EXISTING UNDERGROUND WATER
EXISTING OVERHEAD/UNDERGROUND FIBER
EXISTING UNDERGROUND SANITARY
EXISTING UNDERGROUND/OVERHEAD POWER
SANITARY MANHOLE
STORM MANHOLE
100.00'
LEGEND
= EXISTING GRADE
= PROPOSED GRADE
NOTES:
1. EXISTING GRADE/CONTOUR INFORMATION PRESENTED IN THESE PLANS IS BASED
UPON INFORMATION PROVIDED BY DAVIS WANIC LAND SURVEYORS OF ESCANABA, MI.
CONTRACTOR SHALL CONFIRM ALL INFORMATION. ANY DISCREPANCIES SHALL BE
REPORTED TO THE ENGINEER AND THE SURVEYOR.
2. DURING THE STORM PIPE REPLACEMENT COMPLETED IN 2022, CONDUITS WERE
PLACED ABOVE AND BELOW THE STORM PIPE FOR THE FUTURE RESTROOM BUILDING
WATER AND ELECTRIC UTILITIES. THE PURPOSE OF THE CONDUITS IS TO PREVENT
DIGGING NEAR THE STORM PIPE. CONTRACTOR SHALL EXPOSE THE CONDUITS NEAR
THE ENDS. CONTRACTOR SHALL ACQUIRE THE SERVICES OF DAVIS WANIC TO STAKE
THE LOCATIONS OF THE ENDS OF THE CONDUITS PRIOR TO DIGGING.
C2.0
DSB
DSB
PLAN
NORTH
PLAN
NORTH
BL
EA
C H
ER
S
CONCRETE
STEPS/SLAB
SHED
TR
AC
K
20" MAPLE
EXISTING TENNIS COURTS
SHRUB
STORM MANHOLE
RIM EL 610.58'
PIPE INV EL 604.28'
PIPE INV EL 604.18'
SANITARY MANHOLE
RIM EL 611.67'
PIPE INV EL 607.23'
PIPE INV EL 606.35'
SANITARY MANHOLE
RIM EL 611.52'
PIPE INV EL 605.39'
EXISTING TENNIS COURTS
SPIGOT
SPIGOT
1" OR 2" BURIED
PLASTIC WATER LINESPIGOT
PAVILION
JUNIOR/SENIOR
HIGH SCHOOL
BUILDING
2.
0' C
.T .V
123.5' C.T.V.
6.00'
6.
UNDERGROUND
ELECTRICAL.
SEE NOTES 3.2 AND 3.5
UNDERGROUND WATER.
SEE NOTES 3.3 AND 3.5
UNDERGROUND
SANITARY PIPE.
SEE NOTE 3.4
CO
C3.0CO
C3.0
CO
C3.0
.4
8'
16.18'
32.31'
.0
0'
INCLUDE SIDEWALKS
IN THE BASE BID
611.0
SIDEWALK TO
FOLLOW EXISTING
GRADE ELEVATION
610.25
610.5
610.25
4.5% M.E. 610.72M.E. 610.79
611.17
611.5
611.45
611.45
611.4
611.4
2%
611.17
2%
9% 6%
SANITARY MANHOLE
RIM EL 611.67'
PIPE INV EL 607.23'
PIPE INV EL 606.35'
AT BUILDING:
PIPE INVERT EL = 609.5'
611.5
AT MANHOLE:
PIPE INVERT EL = 606.73'
6" SANITARY PIPE AT 1.04%
(1/8" PER FOOT), LOCATED
HALFWAY BETWEEN THE
TREE AND THE COURT
135.00°'
6" 2'
-0
3'-0" MIN.
BITUMINOUS
PAVEMENT, EARTH
OR CONCRETE.
SEE SITE PLAN
CONTINUOUS STRIP OF METAL
DETECTOR LOCATABLE TAPE
OR 14 GA. WIRE
COMPACTED CLEAN
SAND FILL
UNDERGROUND
ELECTRICAL OR
COMMUNICATIONS
CONDUITS
" U
N D
ER
R
O
AD
S
" O
TH
ER
L
O C
AT
IO
N S
Scale: 1/2" = 1'-0"
ELECTRICAL TRENCH DETAILU2
EARTH
UNDISTURBED EARTH
WATER MAIN
MATERIAL, CLASS II
GRANULAR BEDDING,
UNLESS OTHERWISE
EXISTING GROUND
3'-0" MIN.
EXCAVATED MATERIAL
BACKFILL TRENCH WITH
6"
8' -0
" T O
W
AT
ER
M
AI
N
NOTES
GRANULAR BEDDING SHALL BE 1 1/2" AND SMALLER WITHIN 6" OF PIPE.
BACKFILL SHALL NOT CONTAIN DEBRIS, FROZEN MATERIAL, OR ORGANIC MATERIAL
WITHIN 2' OF THE TOP OF THE PIPE.
1.
2.
EARTH
UNDISTURBED EARTH
6" SANITARY SEWER PIPE
CLASS II [MDOT]
GRANULAR BEDDING MATERIAL,
OTHERWISE BY ENGINEER*
EXISTING GROUND
3'-0" MIN.
2" THK. x 24" W x CONT. RIGID INSULATION
MATERIAL UNLESS INDICATED
BACKFILL TRENCH WITH EXCAVATED
6"
1.
FT
T
O
.9 4F
T
TO
S
AN
IT
AR
Y
PI
PE
OVER THE PIPE THE ENTIRE LENGTH
N.T.S.
UTILITIES TRENCH DETAILU1
INDICATED BY ENGINEER
[MDOT]
Scale: 1/2' = 1'-0"
CLEANOUT DETAILCO
EXTERIOR CLEANOUTS TO BE PLACED SO
AS NOT TO EXCEED A SPACING OF 100'-0"
WYE FITTING
SEE PLANS FOR PIPE SIZE & DIA.
6" - SCHEDULE 40 PVC
PIPE SLEEVE
CRUSHED AGGREGATE FILL
24" SQUARE CONCRETE PAD
NEENAH FOUNDRY FLOOR
BOX FRAME & LID
CLEANOUT PLUG
6" 4"
Z:
\0
0- D
W G
\0 0-
E sc an ab a Ar ea P ub lic
S ch oo ls
\2 2-
H ig h Sc ho ol
A th le tic
B at hr oo m B ui ld in g, E sc an ab a, M
I\2 2-
_C iv il.
dw g
/3
1/
0:
:2
AM
R E
V
IS
IO
N
D A
TE
Date
Drawn By
Checked By
Job No.
P ro je ct
T itl e
Dynamic Design Group, inc.
900 1st Ave. So., Ste. A
Escanaba, MI ph.: 906.786.3300 email: gen@ddgi-ddm.com www.ddgi-ddm.com
M d d
COPYRIGHT 2020 DYNAMIC
DESIGN GROUP, INC., ESCANABA, MI.
This document is not to be used, copied or reproduced without expressed written permission from Dynamic Design Group, inc.
F O
R R
E V
IE
W
/F O
R C
O N
S T
R U
C T
IO
N
ES
C
A N
A B
A , M
IC
H
IG
A
N
ES
C
A N
A B
A A
R
EA
P U
B
LI
C S
C H
O O
LS
H
IG
H
S C
H O
O L
A
TH
LE
TI
C R
ES
TR
O O
M B
U
IL
D
IN
G
03-31-2025
22-4520Scale: 1"=40'
PROPOSED SITE/UTILITY PLAN1
C3.0
DSB
DSB
6x6 W2.9xW2.9 WWF
CONTROL JOINT SPACING = 36 TIMES THE
CONCRETE THICKNESS, BUT NOT
GREATER THAN 1 1/2 TIMES THE WIDTH.
TOOLED JOINT
CONTROL JOINT DEPTH = 1/4 CONC THICKNESS.
2.TOOLED JOINT
1/2" PRE-MOULDED JOINT FILLER
#4x12" DOWEL 16:o.c.
NOTES:
1. ALL EXTERIOR CONCRETE SLABS FOR WALKING SURFACES SHALL BE 4" THICK WITH 6X6 W.W.F. OVER 12" OF WELL COMPACTED SAND
SUB-BASE. ALL EXTERIOR CONCRETE SLABS THAT WILL EXPERIENCE VEHICULAR TRAFFIC SHALL BE 6" THICK WITH 6X6 W.W.F. OVER 12"
OF WELL COMPACTED SAND SUB-BASE.
2. TRACK REPAIR - ASPHALT SHALL BE TWO (2) LAYERS OF 1 1/2" THICK MDOT 4EL. IF BOTH LAYERS ARE PLACED ON THE SAME DAY, NO TACK COAT IS REQUIRED. IF THE WEARING COURSE IS NOT PLACED ON THE SAME DAY AS THE BINDER COURSE, A TACK COAT SHALL BE
APPLIED TO THE BINDER COURSE PRIOR TO PLACEMENT OF THE WEARING COURSE.
3. UTILITIES:
3.1. CONTRACTOR SHALL COORDINATE ALL HIGH SCHOOL BUILDING UTILITY SHUTDOWNS WITH THE OWNER, TO DETERMINE THE BEST
DAY/TIME FOR THE REQUIRED SHUTDOWN. PROVIDED THE OWNER WITH AT LEAST A ONE WEEK NOTICE.
3.2. ELECTRICAL - SEE NOTE 2 ON SHEET C2.0. SEE DETAIL U2/C3.0 AND ELECTRICAL PLANS.
3.3. WATER - SEE NOTE 2 ON SHEET C2.0. SEE DETAIL U1/C3.0 AND PLUMBING PLANS.
3.4. SANITARY - 6" PVC SDR 26 SANITARY PIPE ROUTED AT 1% (1/8" PER FOOT) TO THE EXISTING MANHOLE SOUTH OF THE HIGH SCHOOL
GYMNASIUM. SEE PLAN 3/C3.0 AND DETAIL U1/C3.0. SEE PLUMBING PLANS.
3.5. ALTERNATE #2 - INCLUDE AN ADDITIONAL 2" BURIED CONDUIT (AND PULL WIRE) FROM THE EXISTING HIGH SCHOOL TO THE NEW
RESTROOM BUILDING AND UPSIZE THE 1" WATER SUPPLY PIPE TO A 2" WATER SUPPLY PIPE. SEE PLUMBING AND ELECTRICAL PLANS.
1.
NOTES:
SAND SUBGRADE
BROOM FINISH
GREASE 1/2 OF DOWEL MIN.
6x6 W2.9xW2.9 WWF
EXPANSION JOINT CONTROL JOINT
12" COMPACTED
12"
SAND SUBGRADE
12" COMPACTED
EXPANSION JOINT SPACING = 30FT1.
NOTES:
LAWN
TOPSOIL
Scale: N.T.S.
SIDEWALK DETAILSS1
FIN. GRADE
SEE SITE PLAN
12" COMPACTED
SAND SUBBASE
Scale: N.T.S.
EDGE OF CONCRETE DETAILEC
COMPACTED LOCAL FILL AS
REQUIRED TO MEET GRADES
REMOVE EXISTING
ORGANIC MATERIAL
6" OF TOPSOIL,
SEED AND MULCH
SEE SITE PLAN
FOR SLOPES
C3.0
CD1
Scale: N.T.S.
CONCRETE DETAILCD1
12" COMPACTED
SAND SUBBASE
CONCRETE. SEE NOTE 1
6X6 X 2.9X2.9 WWF
COMPACTED ENGINEERED
FILL OF DEPTH REQUIRED
TO MEET GRADES
4"
4"4"
C3.0 S1
CIVIL KEY - PROPOSED
NEW CONCRETE. SEE DETAIL CD/S4.0.
GRASS
ALL EXISTING GRASS AREAS
AFFECTED BY WORK TO BE
REPAIRED WITH TOPSOIL,
SEEDED AND MULCHED
SANITARY MANHOLE
STORM MANHOLE
Scale: 1"=20'
PROPOSED GRADES PLAN2
PLAN
NORTH
ALTERNATE #1:
6FT SIDEWALK FROM THE ATHLETIC
RESTROOM BUILDING TO THE
PROPOSED TENNIS PAVILION.
RUN PARALLEL TO THE FENCE
C3.0
EC
C3.0
CD1
C3.0
CD1
PLAN
NORTH
Scale: 1"=30'
PROPOSED SANITARY PIPE3 PLAN
NORTH
5'-6"
AT
TI
C
AC
C
ES
S
BABY
CHANGING
STATION
BABY
CHANGING
STATION
WOMEN
MEN
JAN.
'-0
22'-0" 5 1/2"
10'-3 3/4" 5 1/2"
10'-3 3/4" 5 1/2"
1/
2"
'-1
8' -3
DRINKING FOUNTAINS.
SEE NOTE 1
3' -0
5'
-2
SEE ELECTRICAL AND PLUMBING
PLANS FOR ALL FIXTURES
1/
2"
3'-4"
SEE NOTE 1
5'-4"
SEE NOTE 1
7'-4" 7'-4"
5 1/2" 5 1/2" 5 1/2" 5 1/2"
6' -4
/2
AT
TI
C
AC
C
ES
S
WOMEN
MEN
JAN.
5'-0" (TYP)
SHINGLES:
CERTAINTEED LANDMARK PREMIUM.
COLOR: MAX DEF MOIRE BLACK
OVER UNDERLAYMENT AS SPECIFIED
BY THE SHINGLE MANUFACTURER
(TYP ALL ROOF SURFACES)
STANDARD STEEL SIDING.
COLOR: OWNER SELECTED
FROM STANDARD COLOR LIST
(TYP ENTIRE BUILDING)
METAL SOLID SOFFIT.
COLOR: GRAY AS SELECTED BY THE OWNER
(TYP ALL HORIZONTAL SOFFIT)
LOUVER (TYP).
COLOR: GRAY AS SELECTED
BY THE OWNER
(TYP IN 2 LOCATIONS).
SEE MECHANICAL PLANS
METAL FASCIA AND DRIP EDGE.
COLOR: GRAY AS SELECTED BY THE OWNER
(TYP ENTIRE BUILDING)
4" STANDARD STEEL SIDING CORNER TRIM
COLOR: OWNER SELECTED FROM
STANDARD COLOR LIST
(TYP ALL CORNERS)
Z:
\0
0- D
W G
\0 0-
E sc an ab a Ar ea P ub lic
S ch oo ls
\2 2-
H ig h Sc ho ol
A th le tic
B at hr oo m B ui ld in g, E sc an ab a, M
I\2 2-
_P la n.
dw g
/3
1/
0:
:3
AM
R E
V
IS
IO
N
D A
TE
Date
Drawn By
Checked By
Job No.
P ro je ct
T itl e
Dynamic Design Group, inc.
900 1st Ave. So., Ste. A
Escanaba, MI ph.: 906.786.3300 email: gen@ddgi-ddm.com www.ddgi-ddm.com
M d d
COPYRIGHT 2020 DYNAMIC
DESIGN GROUP, INC., ESCANABA, MI.
This document is not to be used, copied or reproduced without expressed written permission from Dynamic Design Group, inc.
F O
R R
E V
IE
W
/F O
R C
O N
S T
R U
C T
IO
N
ES
C
A N
A B
A , M
IC
H
IG
A
N
ES
C
A N
A B
A A
R
EA
P U
B
LI
C S
C H
O O
LS
H
IG
H
S C
H O
O L
A
TH
LE
TI
C R
ES
TR
O O
M B
U
IL
D
IN
G
03-31-2025
22-4520Scale: 1/4"=1'-0"
FLOOR PLAN1
OCCUPANCY CALCULATIONS FOR FIXTURE COUNTS
FALL SEASONS
TENNIS - GIRLS
DAILY PRACTICE = 25 ATHLETES + 2 COACHES = 27 PEOPLE
COMPETITION DAYS = 24 ATHLETES COMPETING + 12 ATHLETES WATCHING + 4 COACHES + 36 PARENTS = 76 PEOPLE
7TH & 8TH GRADE FOOTBALL
DAILY PRACTICE = 60 ATHLETES + 4 COACHES = 64 PEOPLE
COMPETITION DAYS = 120 ATHLETES + 8 COACHES + 120 SPECTATORS = 248 PEOPLE
CROSS COUNTRY = 25 ATHLETES + 2 COACHES = 27 PEOPLE
COMPETITION HELD ELSEWHERE
SPRING SEASONS
TENNIS - BOYS
DAILY PRACTICE = 30 ATHLETES + 2 COACHES = 32 PEOPLE
COMPETITION DAYS = 24 ATHLETES COMPETING + 12 ATHLETES WATCHING + 4 COACHES + 36 PARENTS = 76 PEOPLE
TRACK
DAILY PRACTICE = 60 ATHLETES + 8 COACHES = 68 PEOPLE
COMPETITION DAYS = 180 ATHLETES + 24 COACHES + 20 WORKERS + 180 SPECTATORS = 404 PEOPLE
WORST CASE SCENARIO = FALL TENNIS AND TRACK COMPETITIONS ON THE SAME DAY = 480 PEOPLE
FIXTURE REQUIREMENTS PER MICHIGAN CODE
240 MEN (HALF OF TOTAL) X 1 FIXTURE PER 75 MEN = 3.2 FIXTURES = 4 REQUIRED.
OF THE 4 FIXTURES, 2 OF THE FIXTURES MUST BE WATERCLOSETS AND 2 URINALS.
240 WOMEN (HALF OF TOTAL) X 1 FIXTURE PER 40 WOMEN = 6 FIXTURES REQUIRED.
LAVATORIES FOR MEN = 1 PER 200 MEN = 1.2 LAVATORIES = 2 LAVATORIES REQUIRED.
LAVATORIES FOR WOMEN = 1 PER 150 WOMEN = 1.6 LAVATORIES = 2 LAVATORIES REQUIRED.
DRINKING FOUNTAIN = 1 PER 1000 PEOPLE = 1 DRINKING FOUNTAIN REQUIRED.
DRINKING FOUNTAIN MUST ALLOW ACCESSIBILITY FOR BOTH STANDING AND SITTING. IF A SINGLE DRINKING FOUNTAIN DOES NOT MEET THIS REQUIREMENT, THEN TWO DRINKING FOUNTAINS MUST BE PROVIDED, ONE FOR STANDING AND ONE FOR SITTING.
SERVICE SINK = 1 SERVICE SINK REQUIRED, TO ALLOW CLEANING OF THE FACILITY.
MICHIGAN CODE ALLOWS AN EXCEPTION TO THE CODE REQUIREMENT IF RESTROOMS IN THE SCHOOL BUILDING ARE WITHIN 500 FT OF THE SPORT ACTIVITIES. THIS IS CURRENTLY THE CASE, THUS THIS EXCEPTION IS APPLIED TO
ALLOW A REDUCTION IN THE FIXTURE COUNT.
PLAN
NORTH
Scale: 1/4"=1'-0" EAST ELEVATION3AScale: 1/4"=1'-0"
NORTH AND SOUTH ELEVATIONS3C
A1.0
DSB
DSB
A1.1
NOTES:
1. INSTALL FLAT STEEL PANEL, OF MATCHING COLOR, FOR AREA BEHIND THE DRINKING FOUNTAINS. THE
DRINKING FOUNTAIN AREA SHALL BE 40"X48". CONTRACTOR TO VERIFY SIZE OF THE AREA WITH THE FINAL DRINKING FOUNTAIN UTILIZED AND ADJUST ACCORDINGLY, TO MAKE AS SMALL OF A FLAT STEEL AREA AS POSSIBLE. WRAP AREA WITH J TRIM. FLAT STEEL SHALL BE A SEAMLESS PANEL AND SHALL OVERLAP A
MINIMUM OF 6" UNDER THE STEEL SIDING.
Scale: 1/4"=1'-0"
FLOOR PLAN - NO DIMENSIONS1 PLAN
NORTH
Scale: 1/4"=1'-0"
WEST ELEVATION3B
SEE PLUMBING PLANS FOR PLUMBING
VENTS THROUGH THE ROOF. PROVIDE
WEATHER TIGHT FLASHINGS.
A1.1
NON-POWERED STATIC ROOF VENT (TYP 4 LOCATIONS):
SLANT BACK; HEAVY-DUTY ALUMINUM; 50 SQUARE INCHES OF NET
FREE AREA; FILTER; BLACK
ACCEPTABLE MANUFACTURES INCLUDE:
AIRHAWK SLA SLANT ALUMINUM, MODEL SLABL, PART #85282
OR EQUIVALENT
UNDER EAVE VENT (TYP 8 LOCATIONS):
4X16; HEAVY-DUTY ALUMINUM; PRE-FINISHED; 8 MESH ALUMINUM
SCREEN; 28 SQUARE INCHES OF NET FREE AREA; WHITE.
ACCEPTABLE MANUFACTURES INCLUDE:
AIRVENT EV16424
OR EQUIVALENT
CENTER OF THE VENT TO BE 2FT FROM THE WALL (CENTERED IN
THE SOFFIT)
PROVIDE BLOCKING BETWEEN THE TRUSS MEMBERS FOR
SECURING THE VENT AND SOFFIT MATERIALS
G0.3
SI
G0.3
SI
DRINKING
FOUNTAINS.
SEE NOTE 1
WALL PANELS:
MFGR: METAL SALES OR APPROVED EQUAL.
STYLE: CLASSIC RIB
GAUGE: 29 GALVALUME
FINISH: COLOR FIT 40
SIZE: 36" COVERAGE, 3/4" RIB HEIGHT, FULL HEIGHT
COLOR: SELECTED BY OWNER FROM MFGR. STANDARD
COLORS.
CLOSURE STRIPS: YES
TRIMS: FROM MFGR., MATCH COLOR AND FINISH.
FASTENERS: BY MFGR., HEX HEAD SCREW TYPE, COLORED
TO MATCH PANEL, GASKETED.
WARRANTY: MFGRS. STANDARD FOR PANEL AND FINISH.
SHINGLES:
MFGR: CERTAINTEED OR APPROVED EQUAL.
STYLE: LANDMARK, ARCHITECTURAL PROFILE
WEIGHT: 240 POUNDS PER SQUARE
COLOR: SELECTED BY OWNER.
FASTENERS: NON CORROSIVE / NON STAINING AS
RECOMMENDED BY MANUFACTURER.
UNDERLAYMENT: WINTERGUARD, SELF ADHEARING.
8' -6
/2
2' -0
/8
" H
EE
L
5/8" ROOF SHEATHING.
SEE DETAIL RS/S1.1
MANUFACTURED/ENGINEERED
TRUSSES AT 24" O.C.
SEE NOTE ON SHEET G0.2 RIDGE VENT
CONTINUOUS CONCRETE FOOTING.
SEE FOUNDATION PLAN (TYP)
PAINTED 5/8" GYPSUM CEILIING
(TYP ALL CEILINGS U.N.O.)
4" CONCRETE SLAB.
SEE DETAIL 1/S1.1 (TYP)
SEE DETAIL W1 OR W2
ON SHEET S1.1 (TYP)
4'-0" (TYP)
6FT OF ICE & WATER SHIELD
AT ALL EAVES
PROVIDE BLOCKING FOR METAL
SOFFIT, EAVE VENTS AND LIGHTS.
SEE ELECTRICAL PLANS
EXTERIOR WALLS (TYP)
PREFINISHED 29 GA. METAL SIDING
BUILDING WRAP
1/2" SHEATHING
R-21 UNFACED BATT. INSULATION
2x6 FRAMING @ 16" O.C.
6 MIL. VAPOR BARRIER
1/2" SHEATHING
FRP PANEL
INTERIOR WALLS (TYP)
FRP PANEL
1/2" SHEATHING
2x6 FRAMING @ 16" O.C.
1/2" SHEATHING
FRP PANEL
PRESS PLATE TRUSSES
R-21 UNFACED BATT. INSUL.
6 MIL. VAPOR BARRIER
5/8" SHEATHING
FRP PANEL
8' -1
/8
6"
100'-0"
TOP OF FLOOR
4'-0" (TYP)
METAL BUILDING TRIM
PREFINISHED 29 GA. METAL SIDING
1/2" SHEATHING
ANCHOR BOLT.
SEE DETAILS W1 AND W2 ON S1.1
TREATED WOOD PLATE
SEE DETAILS W1 AND W2 ON S1.1
FRP PANEL
R-21 UNFACED BATT. INSULATION
CONCRETE FOUNDATION (SEE STRUCTURAL)
CONCRETE SLAB
(SEE STRUCTURAL)
100'-6"
TOP OF CONCRETE STEM WALL
100'-0"
TOP OF FLOOR
1/2" SHEATHING
TRACK
6" WIDE x 1/2" THICK PVC BASE
WITH SMOOTH FINISH.
SECURE TO WALL WITH ADHESIVE AND
APPROPRIATE FASTENERS @ 16" O.C.,
1 1/2" FROM THE TOP OF THE BASE.
FRP PANEL
R-21 UNFACED BATT. INSULATION
1/2" SHEATHING.
WRAP OVER PVC BASE
TO COVER FASTENERS
6" WIDE x 1/2" THICK PVC BASE
WITH SMOOTH FINISH.
SECURE TO WALL WITH ADHESIVE AND
APPROPRIATE FASTENERS @ 16" O.C.,
1 1/2" FROM THE TOP OF THE BASE.
FRP TRACK
1/
2"
ANCHOR BOLT.
SEE DETAILS W1 AND W2 ON S1.1 (SIM)
Z:
\0
0- D
W G
\0 0-
E sc an ab a Ar ea P ub lic
S ch oo ls
\2 2-
H ig h Sc ho ol
A th le tic
B at hr oo m B ui ld in g, E sc an ab a, M
I\2 2-
_P la n.
dw g
/3
1/
0:
:4
AM
R E
V
IS
IO
N
D A
TE
Date
Drawn By
Checked By
Job No.
P ro je ct
T itl e
Dynamic Design Group, inc.
900 1st Ave. So., Ste. A
Escanaba, MI ph.: 906.786.3300 email: gen@ddgi-ddm.com www.ddgi-ddm.com
M d d
COPYRIGHT 2020 DYNAMIC
DESIGN GROUP, INC., ESCANABA, MI.
This document is not to be used, copied or reproduced without expressed written permission from Dynamic Design Group, inc.
F O
R R
E V
IE
W
/F O
R C
O N
S T
R U
C T
IO
N
ES
C
A N
A B
A , M
IC
H
IG
A
N
ES
C
A N
A B
A A
R
EA
P U
B
LI
C S
C H
O O
LS
H
IG
H
S C
H O
O L
A
TH
LE
TI
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .