221010 Drive Train Fab Drawings.pdf

PDF 774 KB Posted

Attached to
221010 Hangar Door Repairs/Upgrades
Solicitation number
ITB-09782
Issued by
Duval County, Florida

About this file

The document provided contains fabrication drawings for custom components intended for the hangar doors located at Building 860, 13650 Aerospace Way. These drawings are part of a state and local contract opportunity issued by the Florida Department of Transportation (FDOT) and Duval County to repair and upgrade the maintenance hangar doors. The scope of work includes alignment and structural integrity inspections, replacement of various drive components, electrical and electronic control systems, and other door hardware. Bidders are required to fabricate the components offsite in a controlled environment and are prohibited from onsite fabrication or welding. Prior to fabrication, the contractor must provide a fit test of the mounting frame to the existing door structure for each door leaf. The contract opportunity does not specify quantities, response dates, award dates, or contract term.

The pricing terms, set asides, funding sources, and other financial details are not provided in the document. However, it is noted that the contract is for the sole use of the hangar doors at the specified location, and substitutions of components are only permitted for obsolete or unsupported parts with written consent from the engineer of record.

View the file

Other files

File Type Posted
221010 Hangar Doors SOW-Specs.pdf PDF
221010 Invitation To Bid .pdf PDF
221010 Proposal Form-SubList.docx DOCX document
221010 PART 1-Supplemental Conditions.pdf PDF
221010 - ADDENDUM #1.pdf PDF
221010 - ADDENDUM #2.pdf PDF
221010 PART 1-Supplemental Conditions.pdf PDF
221010 Part 2- General Terms & Conditions.pdf PDF
221010 PART 1-Supplemental Conditions.pdf PDF
221010 Part 2- General Terms & Conditions.pdf PDF
221010 - ADDENDUM #1.pdf PDF
221010 Proposal Form-SubList.docx DOCX document
221010 Part 2- General Terms & Conditions.pdf PDF
221010 - FNG5085.docx DOCX document
221010 Invitation To Bid .pdf PDF
221010 PART 1-Supplemental Conditions.pdf PDF
221010 - ADDENDUM #1.pdf PDF
221010 Drive Train Fab Drawings.pdf PDF
221010 Invitation To Bid .pdf PDF
221010 - FNG5085.docx DOCX document
221010 Drive Train Fab Drawings.pdf PDF
221010 - FNG5085.docx DOCX document
221010 Drive Train Fab Drawings.pdf PDF
221010 Hangar Doors SOW-Specs.pdf PDF
221010 Proposal Form-SubList.docx DOCX document
221010 Part 2- General Terms & Conditions.pdf PDF
221010 Hangar Doors SOW-Specs.pdf PDF
221010 Proposal Form-SubList.docx DOCX document
221010 bid tabulation.pdf PDF
221010 Hangar Doors SOW-Specs.pdf PDF
221010 Invitation To Bid .pdf PDF
221010 - ADDENDUM #2.pdf PDF
221010 - FNG5085.docx DOCX document
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

225 E. Robinson Street, Suite 145.

Orlando, Florida 32801

Phone: 407-422-1118

Fax: 407-841-9149 www.cscos.com

C&S Engineers, Inc.

Copyright c

SHEET 1 OF 8

DRAWN BY: B. CURRIE, P.E.

CHECKED BY:

DESIGNED BY: B. CURRIE, P.E.

DATE: 5/20/2024

PROJECT: Z64.001.001

REVISIONS

MARK DATE DESCRIPTION

A A

S F

B

U I L D

I N

G

H

A N

G A

R

D

O O

R

D

R I V

E

T

R A

I N

COVER SHEET

THESE FABRICATION DRAWINGS REPRESENT CUSTOM COMPONENTS INTENDED FOR THE SOLE

USE OF THE HANGAR DOORS IN USE AT BUILDING 860, LOCATED AT 13650 AEROSPACE WAY.

THESE COMPONENTS ARE NOT ENGINEERED TO BE UTILIZED FOR ANY OTHER PURPOSE OR

LOCATION.

NOTES TO BIDDERS:

I. COMPONENTS SHALL BE FABRICATED OFFSITE IN A CONTROLLED ENVIRONMENT. ONSITE

FABRICATION AND/OR WELDING IS PROHIBITED.

II. SUBSTITUTIONS OF COMPONENTS IS NOT PERMITTED WITHOUT WRITTEN CONSENT OF THE

ENGINEER OF RECORD. SUBSTITUTIONS WILL ONLY BE CONSIDERED FOR OBSOLETE OR

UNSUPPORTED COMPONENTS.

III. THESE DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE WRITTEN SCOPE OF WORK

DOCUMENT.

IV. PRIOR TO FABRICATION AND INSTALLATION, CONTRACTOR SHALL PROVIDE A FIT TEST OF

THE MOUNTING FRAME TO THE EXISTING DOOR STRUCTURE. THIS FIT TEST SHALL BE

COMPLETED FOR EACH DOOR LEAF ASSOCIATED WITH A DRIVETRAIN

MOUNT ASSEMBLY (FRONT)

SCALE 1 / 4

MOUNT ASSEMBLY (RIGHT)

SCALE 1 / 4

MOUNT ASSEMBLY (LEFT)

SCALE 1 / 4

MOUNT ASSEMBLY (BACKSIDE)

SCALE 1 / 4

PARTS LIST

DESCRIPTIONPART NUMBERQTYITEM

ASTM A572 GRADE 50 STEELANGLE BRACKET21

ASTM A572 GRADE 50 STEELSQUARE BAR22

ASTM A572 GRADE 50 STEELMOTOR PLATE13

ASTM A572 GRADE 50 STEELTHREADED BLOCK14

MOTOR & GEARBOX ASSEMBLYSK92672.1V-140TC-90LP_4145TCCUSBRE10HLTW15

ANSI 60 15 TEETH SPROCKETMCMASTER CARR 6280K32616

Plain Washer (Inch )Type A and BANSI B18.22.1 - 1/2 - narrow - Type B107

Hex Bolt - UNC (Regular Thread - Inch)ANSI/ASME B18.2.1 - 1/2-13 UNC - 1.25, HBI88

Plain Washer (Inch )Type A and BANSI B18.22.1 - 7/16 - narrow - Type B89

Hex Bolt - UNC (Regular Thread - Inch)ANSI/ASME B18.2.1 - 1/2-13 UNC - 3.25, HBI210

Hex Bolt - UNC (Regular Thread - Inch)ANSI/ASME B18.2.1 - 7/16-14 UNC - 1.75, HBI411

Hex Nuts (Inch Series) Hex NutANSI B18.2.2 - 7/16 - 14, HNI412

BEARING PLATE ASSEMBLY113

225 E. Robinson Street, Suite 145.

Orlando, Florida 32801

Phone: 407-422-1118

Fax: 407-841-9149

SHEET 2 OF 8

DRAWN BY: B. CURRIE, P.E.

CHECKED BY:

DESIGNED BY: B. CURRIE, P.E.

DATE: 5/20/2024

PROJECT: Z64.001.001

REVISIONS

MARK DATE DESCRIPTION

A A

S F

B

U I L D

I N

G

H

A N

G A

R

D

O O

R

D

R I V

E

T

R A

I N

MOTOR & MOUNT

ASSEMBLY

BEARING PLATE ASSEMBLY

SCALE 1 : 1

ISOMETRIC

SCALE 1/2

BEARING PLATE ASSEMBLY

SCALE 1 : 1

PARTS LIST

DESCRIPTIONPART NUMBERQTYITEM

ASTM A572 GRADE 50 STEELBEARING PLATE11

ASTM A572 GRADE 50 STEELBEARING TAB22

ANSI 60 22 TEETH SPROCKETMCMASTER CARR 6280K38613

MOUNTED BALL BEARINGMCMASTER CARR 5967K8424

Plain Washer (Inch )Type A and BANSI B18.22.1 - 1/2 - narrow - Type B85

Hex Bolt - UNC (Regular Thread - Inch)ANSI/ASME B18.2.1 - 1/2-13 UNC - 1, HBI86

ASTM 4140 STEEL ALLOYSHAFT17

ANSI 60 25 TEETH SPROCKETMCMASTER CARR 6236K52318

ASTM A572 GRADE 50 STEELTHREADED BLOCK19

SHEET 3 OF 8

DRAWN BY: B. CURRIE, P.E.

CHECKED BY:

DESIGNED BY: B. CURRIE, P.E.

DATE: 5/20/2024

PROJECT: Z64.001.001

REVISIONS

MARK DATE DESCRIPTION

A A

S F

B

U I L D

I N

G

H

A N

G A

R

D

O O

R

D

R I V

E

T

R A

I N

BEARING PLATE

ASSEMBLY

225 E. Robinson Street, Suite 145.

Orlando, Florida 32801

Phone: 407-422-1118

Fax: 407-841-9149

3.000 3.938 0.125

3.375

1.000 1.000

ALIGN HOLES

2.583 0.250 3.550

2 2

BEARING PLATE

BEARING TAB

SCALE 1 : 1

SHAFT

SCALE 1 : 1

THREADED BLOCK

SCALE 3:1

225 E. Robinson Street, Suite 145.

Orlando, Florida 32801

Phone: 407-422-1118

Fax: 407-841-9149

SHEET 4 OF 8

DRAWN BY: B. CURRIE, P.E.

CHECKED BY:

DESIGNED BY: B. CURRIE, P.E.

DATE: 5/20/2024

PROJECT: Z64.001.001

REVISIONS

MARK DATE DESCRIPTION

A A

S F

B

U I L D

I N

G

H

A N

G A

R

D

O O

R

D

R I V

E

T

R A

I N

BEARING PLATE

ASSEMBLY

COMPONENTS

7.500

2.375 4.250

1.500

1.000

2.750

1.000

6.750

3.500 1.000 1.000 2.000

R.250 TYP

.375

1.750

.750

.531 THRU

R.273 TYP

R.500

1.375

3.000

6.000

.750

2.752

2.752

4.000

R2.500

1.500

R1.946

.500

9.750

.250

R.500

.109

1.000

1.000 .750

1/2-13 UNC - 2B 1.000

MOUNT ASSEMBLY

SCALE 1 / 2

MOUNT ASSEMBLY WITH PLATES

SCALE 1 / 2

DETAIL E

SCALE 1 : 1

DETAIL F

SCALE 1 : 1

E

F

225 E. Robinson Street, Suite 145.

Orlando, Florida 32801

Phone: 407-422-1118

Fax: 407-841-9149

SHEET 5 OF 8

DRAWN BY: B. CURRIE, P.E.

CHECKED BY:

DESIGNED BY: B. CURRIE, P.E.

DATE: 5/20/2024

PROJECT: Z64.001.001

REVISIONS

MARK DATE DESCRIPTION

A A

S F

B

U I L D

I N

G

H

A N

G A

R

D

O O

R

D

R I V

E

T

R A

I N

MOUNT ASSEMBLY

4.250

.750

(REQ'D FOR MOUNTING PLATE)

ALIGN MOUNTING HOLES

1.250ADJ 1.000

MOUNTING PLATE INTENDED TO

SLIDE ALONG SQUARE STOCK

BEARING PLATE INTENDED TO

SLIDE ALONG SQUARE STOCK

3/16

3/16

3/16

3/16

MOTOR PLATE ADJUSTMENT

BEARING PLATE ADJUSTMENT

.750

(REQ'D FOR BEARING PLATE

ADJUSTMENT BOLT

THREADED BLOCK

(WELDED TO MOUNTING PLATE)

ADJUSTMENT BOLT

THREADED BLOCK

(WELDED TO BEARING PLATE)

3/16

3/16

ANGLE BRACKET

SQUARE BAR

SCALE 1 / 2

MOTOR PLATE

SCALE 1 : 1

THREADED BLOCK

SCALE 3 : 1

225 E. Robinson Street, Suite 145.

Orlando, Florida 32801

Phone: 407-422-1118

Fax: 407-841-9149

SHEET 6 OF 8

DRAWN BY: B. CURRIE, P.E.

CHECKED BY:

DESIGNED BY: B. CURRIE, P.E.

DATE: 5/20/2024

PROJECT: Z64.001.001

REVISIONS

MARK DATE DESCRIPTION

A A

S F

B

U I L D

I N

G

H

A N

G A

R

D

O O

R

D

R I V

E

T

R A

I N

MOUNT ASSEMBLY

COMPONENTS

.875 4.250

2.125 5.000

1.000

1.000

9.000

1.000

12.500

7.750

4.724

3.776

R.273 TYP

.469 THRU TYP

2.000 1.000 1.000 3.750

R.250 TYP

.375

1.750

R.500

.750

1.375

.531

1.000

1.000

1/2-13 UNC - 2B 1.000

.750

2.500

2.500

1.250

3.5006.000

.250

.531 THRU

3.000

1.000

2.750

3.750

4.750

10.000

1.250

1/2-13 UNC - 2B 1.250

1/2-13 UNC - 2B 1.250

1/2-13 UNC - 2B 1.250

1/2-13 UNC - 2B 1.250

1.250

24.000

SECTION C-C

SCALE 1/3

SECTION D-D

SCALE 1/3

C

C

D

D

PARTS LIST

DESCRIPTIONPART NUMBERQTYITEM

MOUNT ASSEMBLY11

ANSI 60 ROLLER CHAINANSI 60 Roller Chain22

Plain Washer (Inch )Type A and BANSI B18.22.1 - 1/2 - Regular - Type B43

Hex Bolt - UNC (Regular Thread - Inch)ANSI/ASME B18.2.1 - 1/2-13 UNC - 1.5, HBI44

Plain Washer (Inch )Type A and BANSI B18.22.1 - 1/2 - narrow - Type B45

Hex Nuts (Inch Series) Hex NutANSI B18.2.2 - 1/2 - 13, HNI46

225 E. Robinson Street, Suite 145.

Orlando, Florida 32801

Phone: 407-422-1118

Fax: 407-841-9149

SHEET 7 OF 8

DRAWN BY: B. CURRIE, P.E.

CHECKED BY:

DESIGNED BY: B. CURRIE, P.E.

DATE: 5/20/2024

PROJECT: Z64.001.001

REVISIONS

MARK DATE DESCRIPTION

A A

S F

B

U I L D

I N

G

H

A N

G A

R

D

O O

R

D

R I V

E

T

R A

I N

INSTALLED

ASSEMBLY

1.500 0.250

FIXED SPROCKET ON WHEEL

ADJUST POSITION ON SHAFT TO

ALIGN WITH WHEEL SPROCKET BELOW

EXISTING HOLE LOCATIONS ON DOOR STRUCTURE.

PRIOR TO FIT-UP CONTRACTOR SHALL CONFIRM

MOTOR MOUNT HOLES ARE MINIMUM DISTANCE

SHOWN FROM HOLE CENTER

2.350 IDEAL

1.750 MINIMUM

GEARBOX

MOTOR

RELEASE LEVER

CONTRACTOR SHALL PROVIDE FIT TEST OF MOUNT TO

EACH DOOR LEAF ASSOCIATED WITH A DRIVETRAIN

ASSEMBLY. IDENTIFY ANY HOLES, PROTRUSIONS,

AND/OR OTHER OBSTRUCTIONS TO THE INTENDED

ATTACHMENT POINT.

SECTION A-A

SCALE 1 / 2

A A

B B

225 E. Robinson Street, Suite 145.

Orlando, Florida 32801

Phone: 407-422-1118

Fax: 407-841-9149

SHEET 8 OF 8

DRAWN BY: B. CURRIE, P.E.

CHECKED BY:

DESIGNED BY: B. CURRIE, P.E.

DATE: 5/20/2024

PROJECT: Z64.001.001

REVISIONS

MARK DATE DESCRIPTION

A A

S F

B

U I L D

I N

G

H

A N

G A

R

D

O O

R

D

R I V

E

T

R A

I N

FIELD

MEASUREMENTS

OF EXISTING

GEOMETRY

13.125

13.125

8.000

11.250

7.000

3.000

2.521

18.500

1.125

3.313

7.938

.313

22.688

19.438

1.6251.625

8.313

12.000

.500

1.250

.459

.791

1.000

26.250

.500

.500

.500

1.813

THIS SHEET IS PROVIDED FOR REFERENCE ONLY AND DOES NOT

REPRESENT COMPONENTS THAT REQUIRE FABRICATION UNDER

THIS SCOPE OF WORK.

File details come from the government source that posted it. Updated .