22025002 WSESD RBP BID DRAWINGS - 12feb2024-ISSUED.pdf
PDF 12 MB Posted
- Attached to
- Roof & HVAC Upgrade Projects
- Solicitation number
- RFP-WSES-250000001506-1
- Issued by
- Macomb County, Livonia City, Michigan
About this file
The document is a set of bidding drawings for the West Shore Educational Service District (ESD) HVAC Upgrade and Roof Replacement Project located at 2130 W. U.S. 10 in Ludington, Michigan. The project involves comprehensive mechanical and electrical system upgrades, including demolition of existing infrastructure and installation of new HVAC equipment, boiler piping, electrical systems, and a complete roof replacement. The bidding documents, prepared by Kendra C. Thompson Architects and Nealis Engineering, are dated February 12, 2025, and include detailed mechanical, electrical, and roof plans across multiple drawing sheets covering demolition and proposed improvements.
The project documents outline specific technical requirements for mechanical equipment replacement, including boiler piping schematics, condensing unit schedules, and electrical riser diagrams. The roof replacement includes installing a new 60 mil fully adhered EPDM membrane, cover board, walkway pads, and associated components. The project appears to be funded through the West Shore ESD and involves upgrading the facility's critical infrastructure systems. The drawings provide comprehensive technical specifications for contractors, including detailed demolition notes, equipment schedules, and installation requirements, suggesting a complex and thorough renovation of the educational service district's facility.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 22025002 WSESD RBP 000113.b advertisement for bids.pdf | ||
| 22025002 WSESD RBP BID MANUAL 12FEB2025.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
kendra c.
architects, p.c.
THOMPSON
803 Cherry Street Manistee, MI 49660 tel: 231.723.4195 thompson.kendra@sbcglobal.net www.kendrathompson-architects.com
T100
DRAWING TITLE
KCT PROJECT NO.DRAWN
KCT
REVIEWED
KCT
DATE
SCALE
AS NOTED
DRAWING NO.
SEAL
COVER SHEET
SHEET NO.
NO. REVISIONS / SUBMISSIONS DATE
PROJECT NAME
WEST SHORE ESD
BIDDING DOCUMENTS
T100 COVER SHEET
SCHEDULE OF DRAWINGS:
LUDINGTON, MI
FEBRUARY 12, 2025
HVAC UPGRADE PROJECT
2130 W. U.S. 10
A200 ROOF PLAN
A400 TYPICAL ROOF DETAILS
M100 DEMOLITION MECHANICAL - ENLARGED MECHANICAL ROOM
M101 DEMOLITION MECHANICAL - ENLARGED PENTHOUSE PLANS
C op yr ig ht
Ke nd ra C
. T ho m ps on A rc hi te ct s, P
.C
FEB 2025
KT-22025002
ESD
LUDINGTON, MI
WEST SHORE
HVAC UPGRADE PROJECTS
2130 W. U.S. 10
ROOF REPLACEMENT &
1 BID & PLAN REVIEW SET 2/12/2025
M200 PROPOSED MECHANICAL - ENLARGED MECHANICAL ROOM
M201 PROPOSED MECHANICAL - ENLARGED PENTHOUSE PLANS
M300 MECHANICAL SCHEDULES & DETAILS
E100 DEMOLITION ELECTRICAL - ENLARGED MECHANICAL ROOM
E101 DEMOLITION ELECTRICAL - ROOF PLAN
E200 PROPOSED ELECTRICAL - ENLARGED MECHANICAL ROOM
E201 PROPOSED ELECTRICAL - ROOF PLAN
E300 EXISTING ELECTRICAL RISER DIAGRAM
ROOF REPLACEMENT PROJECT
AND
TS
A
E GAN
IH
ICFO M
T
NO.
KENDRA
CAYE
1301035207
ARCHITECT
L I CENSED
T
ARCH
ITE
C
THOMPSON
Manistee, MI 49660
Kendra C. Thompson
803 Cherry Street t: 231.723.4195
Architects, P.C.
ARCHITECT:
t: 231.933.0510
Nealis Engineering
Traverse City, MI 49686 1419 Industry Drive
MECH/ELECT. ENGINEER
EXIST.
ROOF
EXIST.
MECH.
UNIT
DRAIN
EXIST.
ROOF
DRAIN
EXIST.
PLB'G.
STACKS
EXIST.
MECH.
VENT
EXIST.
METAL
STAIRS
EXIST.
METAL
STAIRS
EXIST. GAS LINE
EXIST.
MECH.
UNIT
EXIST.
ROOF
DRAIN
EXIST.
ROOF
DRAIN
EXIST.
ROOF
DRAIN
EXIST.
ROOF
DRAIN
EXIST.
ROOF
DRAIN
EXIST.
ROOF
DRAIN
EXIST.
ROOF
DRAIN
EXIST.
MECH.
EQUIP.
EXIST.
MECH.
EQUIP.
EXIST.
PLB'G.
STACKS
EXIST.
MECH.
EQUIP.
EXIST.
PLB'G.
STACKS
EXIST.
MECH.
UNIT
EXIST.
MECH.
UNIT
EXIST.
RAISED
EXIST.
MECH.
VENT EXIST.
PLB'G.
STACKS
EXIST.
ROOF
DRAIN
EXIST.
ROOF
DRAIN
EX
IS
T.
G
A S L
IN
E
EXIST.
MECH.
UNIT
EXIST.
MECH.
UNIT
EXIST.
MECH.
VENT
EXIST.
PLB'G.
STACKS
EXIST.
PLB'G.
STACKS
EXIST.
ROOF
DRAIN
EXIST.
ROOF
DRAIN
EXIST.
ROOF
DRAIN
EXIST.
ROOF
DRAIN
EXIST.
ROOF
DRAIN
EXIST. ANTENNA
ON TEMPORARY
PLATFORM W/
BLOCKS FOR WEIGHT
EXIST.
MECH.
STACKS
EXIST.
MECH.
VENT
EXIST.
MECH.
VENT
EXIST.
MECH.
UNIT
EXIST.
PLB'G.
STACKS
EXIST.
ROOF
HATCH
EXIST.
PLB'G.
STACKS
EXIST.
MECH.
VENT
EXIST.
PLB'G.
STACKS
EXIST.
PLB'G.
STACKS
EXIST.
MECH.
VENT
PLATFORM
EXIST.
MECH.
VENT
EXIST.
PLB'G.
STACKS
EXIST.
PLB'G.
STACKS
EXIST.
MECH.
VENT
EXIST. ANTENNA
ON TEMPORARY
PLATFORM W/
BLOCKS FOR WEIGHT
EXIST.
MECH.
VENT
EXIST.
ROOF
DRAIN
EXIST.
ROOF
DRAIN
EXIST.
ROOF
DRAIN
EXIST.
ROOF
DRAIN
EXIST.
PLB'G.
STACKS
TO INSTALL NEW METAL DECK
& ROOF INSULATION TO
MATCH EXIST'G. WHERE MECH.
EQUIPMENT IS TO BE REMOVED
BY HVAC UPGRADE PROJECT -
METAL DECK TO BE 20 GA
MATCHING EXIST'G. DECK PROFILE
& SPANNING FROM EXIST'G. STEEL
ROOF REPLACEMENT CONTRACTOR
SUPPORT TO SUPPORT, FULL 36"
SHEET WIDTH
TO BE REMOVED BY HVAC
VENT & 24" DIA. ROOF STACK
NEW INFILL BY ROOF REPLACEMENT
UPGRADE PROJECT CONTRACTOR -
CONTRACTOR
REMOVED BY HVAC UPGRADE
(2) 10" MECH. STACKS TO BE
INFILL BY ROOF REPLACEMENT
PROJECT CONTRACTOR - NEW
CONTRACTOR
EXIST'G. 30" X 24" ROOF
BID ALTERNATE NO. 1:
ROOF REPLACEMENT AT
ROOF AREA 2
ROOF REPLACEMENT PROJECT TO INCLUDE REMOVAL
OF EXIST'G. MEMBRANE(S), INSTALLATION OF NEW
1/2" COVER BOARD MECHANICALLY ATTACHED,
INSTALLATION OF NEW 60 MIL FULLY ADHERED EPDM
MEMBRANE, WALKWAY PADS AND ASSOCIATED
AS REQUIRED FOR A COMPLETE ROOF SYSTEM
AT ALL AREAS (EXCLUDING ROOF AREA 1 WITH
ROOF AREA 2 PROVIDED AS BID ALTERNATE #1).
GENERAL NOTES:
NOT IN SCOPE OF WORK:
INCLUDE NEW EPDM MEMBRANE @
BOTH SIDES & TOP @ WALL SEPARATING
ROOF AREAS 1 & AREA 3
ROOF REPLACEMENT PROJECT TO
ALL MECHANICAL EQUIPMENT, ROOF DRAINS
AND MISC. EQUIPMENT ARE INDICATED
CONCEPTUALLY. ROOF REPLACEMENT
CONTRACTOR TO FIELD VERIFY ALL EXISTING
CONDITIONS. NOTIFY DESIGN PROFESSIONAL
WHERE EXISTING CONDITIONS ARE IN CONFLICT
WITH DESIGN INTENT FOR ROOF REPLACEMENT
SCOPE OF WORK.
1.
2.
TO INCLUDE WALKWAY PADS
ROOF REPLACEMENT PROJECT
VERIFY FINAL LOCATION IN FIELD
AS CONCEPTUALLY INDICATED
FLASHING, COPING, AND OTHER COMPONENTS
EXIST.
MECH.
VENT
kendra c.
architects, p.c.
THOMPSON
803 Cherry Street Manistee, MI 49660 tel: 231.723.4195 thompson.kendra@sbcglobal.net www.kendrathompson-architects.com
A200
DRAWING TITLE
KCT PROJECT NO.DRAWN
KCT
REVIEWED
KCT
DATE
SCALE
AS NOTED
DRAWING NO.
SEAL
SHEET NO.
NO. REVISIONS / SUBMISSIONS DATE
PROJECT NAME
ROOF
PLAN
SCALE: 1/8" = 1'-0"
ROOF PLAN
C op yr ig ht
Ke nd ra C
. T ho m ps on A rc hi te ct s, P
.C
EXISTING
FEB 2025
KT-22025002
N
ESD
LUDINGTON, MI
WEST SHORE
HVAC UPGRADE PROJECTS
2130 W. U.S. 10
ROOF REPLACEMENT &
1 BID & PLAN REVIEW SET 2/12/2025
INSULATION (SEE NOTES)
RING (V.I.F.)(TYPICAL)
12"
NOTE:
1. INSTALL PER MANUFACTURER'S WARRANTEED
RECOMMENDATIONS.
2. HOLE IN MEMBRANE SHOULD EXTEND A MINIMUM OF 1/2"
BEYOND CLAMPING RING & BE LARGER THAN THE DIAMETER OF
THE LEADER PIPE.
3. INSULATION ADJACENT TO DRAIN TO BE NEW "ELEVATE"
INSULATION W/BONDING SURFACE.
4. CONTRACTOR TO REMOVE EXIST'G. FLASHING DOWN TO METAL
BOWL, REPAIR/REPLACE BROKEN DRAIN COMPONENTS, DRILL &
TAP BROKEN DRAIN BOLTS & REPLACE AS NEEDED.
SUMP AREA FIELD SEAM REQUIREMENTS:
A. INSTALL EPDM TARGET PATCH WHERE
SEAM EDGE IS WITHIN 9" OF DRAIN
COMPRESSION RING PER
MANUFACTURER REQ'MTS.
B. INSTALL 5" LAYER OF MEMBRANE
FLASHING MIN. 3" BEYOND WHERE SEAM
EDGE IS WITHIN 9" TO 18" OF DRAIN
COMPRESSION RING.
CONTINUOUS BEAD
OF ELEVATE WATER
BLOCK
EPDM MEMBRANE
MEMBRANE ADHESIVE
6" MAX
W/UNREINF.
MEMBRANE
FASTENER & SEAM PLATE @
12" O.C. MAX.
LAP SPLICE
EPDM MEMBRANE
METAL COUNTER FLASHING
MEMBRANE FLASHING
GASKETED FASTENER
EXIST'G. EQUIPMENT & FRAME
TRIM (V.I.F.)
USE STAINLESS STEEL SCREWS W/
RUBBER WASHER WHERE REQ'D.
EX
IS
T' G
FR
A M
E (V
.I.
F.
EXIST'G. WOOD NAILER (V.I.F.)
MEMBRANE ADHESIVE
1-1/4" HOT DIPPED GALVANIZED ROOF
NAILS AT 12" O.C. MAX.
EXIST'G. EQUIPMENT CURB
GASKET (V.I.F.)
NOTE:
PRE-MOLDED PIPE FLASHING
EPDM MEMBRANE
R O
U N D
P
EN
ET
R A
TI
O N
3" MIN.
FIELD FABRICATED METAL
HOOD (ONLY IF/WHERE
EXIST'G. LOCATIONS HAVE)
SEALANT PER ROOF
MANUFACTURER
MEMBRANE ADHESIVE
SEALANT
STAINLESS STEEL
CLAMPING RING
(SEE NOTE #5)
1. INSTALL PER MANUFACTURER'S WARRANTEED
RECOMMENDATIONS.
2. REMOVE ALL EXISTING FLASHING, ETC. - PIPE
SURFACE MUST BE FREE OF ALL RUST, GREASE,
INSULATION, ETC.
3. PENETRATION MUST BE ANCHORED TO ENSURE
STABILITY.
4. PIPE FLASHING MAY BE CUT TO HEIGHT, BUT NO
LOWER THAN REINFORCING RING (NO WRINKLES OR
FOLDS UNDER CLAMPING RING).
5. APPLY WATERBLOCK BETWEEN PENETRATION AND
PRE-MOLDED PIPE FLASHING PRIOR TO INSTALLATION
OF CLAMPING RING.
6. DO NOT USE WHEN SERVICE LINE TEMP. EXCEEDS
MANUFACTURER'S RECOMMENDATIONS FOR INSTALL.
PRIMER PER MANUF.
PE
N
ET
R A
TI
O N
NEW 1/2" COVER BOARD
3" MIN.
" M
IN
FABRIC FLASHING BASE LAYER
STEP 2 STEP 3
3" MIN.
STEP 1
2" (51 mm) MIN
/4
" M
IN
1/4" MIN.
NOTE:
1. INSTALL PER MANUFACTURER'S WARRANTEED
RECOMMENDATIONS.
2. APPLY SINGLE-PLY PRIMER TO ALL SINGLE-PLY
SURFACES.
3. APPLY LIQUID FLASHING WITH A MIN. BOTTOM
COAT OF 30 MIL WET THICKNESS AND MINIMUM
TOP COAT OF 30 MIL WET THICKNESS.
4. DETAIL (INCLUDING FABRIC) MUST EXTEND 3" MIN.
BEYOND EDGE OF MECHANICAL ATTACHMENT.
5. FULLY ENCAPSULATE FABRIC WITH LIQUID
FLASHING. MASK LIQUID FLASHING PERIMETER
EDGE TO MAINTAIN THICKNESS. DO NOT FEATHER
EDGE OF LIQUID FLASHING.
6. ALL SURFACES MUST BE COATED WITH ONE PART
POURABLE SEALER PRIOR TO THE NEXT
OVERLAPPING FABRIC. DRY LAPPING OF FABRIC IS
NOT ALLOWED.
PRIMER PER
MANUFACTURER
EPDM MEMBRANE
2 LAYERS ONE-PART POURABLE
SEALER LIQUID FLASHING
(SEE NOTE #3)
FASTENER PER MANUFACTURER
FABRIC FLASHING VERTICAL WRAP
EPDM MEMBRANE
NOTE:
1. INSTALL PER MANUFACTURER'S WARRANTED
RECOMMENDATIONS.
2. METAL COUNTER-FLASHING SHALL BE 24 GAUGE
PRE-FINISHED STEEL OR .032" MIN. ALUMINUM FORMED
WITH HEMMED LOWER EDGE.
3. NEW COUNTER FLASHING TO BE INSTALL MIN. 8" ABOVE
ROOFING MEMBRANE (MATCH EXIST'G. LOCATION OR
INSTALL AT HIGHER MASONRY JOINT WHERE INDICATED
OTHERWISE).
4. INSTALL ELEVATE TERMINATION BAR WITH 14" SPACE
BETWEEN ADJOINING SECTIONS.
5. TERMINATION BAR MUST BE CUT AT INSIDE AND OUTSIDE
CORNERS - NO BENDING AT CORNERS ALLOWED.
6. TERMINATION BAR MUST BE FASTENED WITHIN
1" MAX. OF ALL SECTION ENDS.
7. INSTALL METAL WORK IN ACCORDANCE WITH CURRENT
SMACNA RECOMMENDATIONS.
APPROPRIATE FASTENER
12" O.C. MAX.
CONTINUOUS BEAD
OF SEALANT
CONTINUOUS BEAD OF
WATER BLOCK PER
MANUFACTURER
RECOMMENDATIONS
METAL COUNTER-FLASHING
6" MIN. FACE - INSTALL
MIN. 8" ABOVE ROOFING
(MATCH EXIST'G. LOCATION
OR AS OTHERWISE
INDICATED)
MEMBRANE ADHESIVE
CONTINUOUS BEAD
OF SEALANT
TERMINATION BAR
(SEE NOTES)
1/2" MIN.
(SEE NOTE #2)
2"
EXIST'G. ROOF DECK EXIST'G. ROOF DECK
FABRIC FLASH'G.
EXIST'G. ROOF DECK
NEW 1/2" COVER BOARD
EXIST'G. ROOF DECK
EXIST'G. INSULATION
EXIST'G. MASONRY
WALL SURFACE
(V.I.F.)
BASE TIE-IN AS REQ'D.
PER MANUFACTURER
RECOMMENDATIONS
EXIST'G. CURB
FASTENER (V.I.F.)
EXIST'G. ROOF DECK
& EXIST'G. ROOF DRAIN
EXIST'G. STRAINER BASKET
EXIST'G. ROOF DECK EXIST'G. ROOF DECK
EXIT'G. COMPRESSION
EXIST'G. INSULATION
OVER EXIST'G. ROOF
NEW 1/2" COVER BOARD
INSULATION SYSTEM ON
EXIST'G. ROOF DECK
OVER EXIST'G. ROOF
NEW 1/2" COVER BOARD
INSULATION SYSTEM ON
EXIST'G. ROOF DECK
INSULATION SYSTEM ON EXIST'G ROOF DECK
NEW 1/2" COVER BOARD OVER EXIST'G ROOF
INSULATION SYSTEM ON EXIST'G ROOF DECK
NEW 1/2" COVER BOARD OVER EXIST'G ROOF
EXIST'G. ROOF DECK
WALL / CURB
APPROPRIATE PRIMER
" M
IN
(5
.8 m m
2" METAL PLATE POSITIONED
1/2" BEYOND WALL/CURB
NOTE:
1. INSTALL PER MANUFACTURER'S
WARRANTEED INSTRUCTIONS.
2. MAXIMUM 6" LONG FASTENERS. (NOTE:
WOOD BLOCKING MAY BE SUBSTITUTED
FOR INSULATION TO REDUCE FASTENER
LENGTH REQUIREMENT).
3. ROOF MANUF. BATTEN STRIP MAY BE
USED IN LIEU OF 2″ METAL PLATES.
4. QUICKSEAM FORMFLASH SHOULD BE
WARMED TO ENSURE FORMABILITY.
5. 6″ QUICKSEAM SPLICE TAPE MAY BE
USED IN LIEU OF 3″ TAPE AND 6″
QUICKSEAM FORMFLASH COVER STRIP.
2" METAL PLATE FASTENED WITH ROOF FASTENERS AT
12" O.C. MAX.
USE APPROPRIATE
TERMINATION
.060" MEMBRANE OR
QUICKSEAM CURB FLASHING
.060" EPDM MEMBRANE
3" QUICKSEAM SPLICE TAPE
APPROPRIATE BONDING
ADHESIVE
6" QUICKSEAM FLASHING
OVER EXIST'G. ROOF
NEW 1/2" COVER BOARD
INSULATION SYSTEM ON
EXIST'G. ROOF DECK
WALL
EXIST'G. ROOF DECK
NOTE:
1. INSTALL PER MANUFACTURER'S WARRANTED RECOMMENDATIONS
3. INSTALL METAL WORK PER MANUFACTURER'S WARRANTED RECOMMENDATIONS.
3. LAP SEALANT IS REQUIRED ALONG ENTIRE UP SLOPE EDGE OF QUICKSEAM FLASHING WHEN ROOF SLOPE IS
1" PER FOOT OR GREATER.
4. WOOD NAILER MUST BE INSTALLED TO MEET APPLICABLE BUILDING CODES.
5. FLANGE OF METAL MUST BE FULLY SUPPORTED BY WOOD AND TERMINATED AT LEAST 1/2" FROM EDGE OF WOOD.
6. IF FLANGE OF METAL EDGE IS NOT COMPLETELY COVERED WITH QUICKSEAM FLASHING, THEN AN ADDITIONAL
PIECE OF QUICKSEAM FLASHING SHALL BE INSTALLED AT ALL METAL SPLICES.
7. INCLUDE 6" WIDE CONCEALED SPLICE PLATES.
8. CONCEALED SPLICE PLATES MUST BE FIELD CAULKED TO PREVENT WATER ENTRY.
CONTINUOUS BEAD OF
APPROPRIATE ECOWHITE
LAP SEALANT (REQUIRED)
1 1/4" STAINLESS
STEEL RING SHANK
SHANK 5D COMMON NAILS
@ 12" O.C. - LOCATION
BASED ON HEIGHT
WOOD NAILER
METAL FASCIA - MATCH
EXIST'G. FACE HEIGHT (5" +/-)
22 GA. GALV. STEEL
CONTINUOUS CLEAT
ACCEPTABLE PRIMER
O.06" EPDM MEMBRANE
ACCEPTABLE MEMBRANE
ADHESIVE
1 3/4" STAINLESS STEEL RING
SHANK 5D COMMON NAILS @ 4"
O.C. MAX. STAGGERED 1/2"
CONTINUOUS BEAD OF LAP
APPROPRIATE SEALANT
1 1/4" HOT DIPPED
GALVANIZED ROOF
NAILS @ 6" O.C. MAX.
6" QUICKSEAM FLASHING
1 2 " M
IN
" M
IN
M A
TC
H E
XI
S T' G
(5
8"-1/4" MIN.
16"
2" MIN.
NEW 1/2" COVER BOARD
EXIST'G. INSULATION
kendra c.
architects, p.c.
THOMPSON
803 Cherry Street Manistee, MI 49660 tel: 231.723.4195 thompson.kendra@sbcglobal.net www.kendrathompson-architects.com
A400
DRAWING TITLE
KCT PROJECT NO.DRAWN
KCT
REVIEWED
KCT
DATE
SCALE
AS NOTED
DRAWING NO.
SEAL
SHEET NO.
NO. REVISIONS / SUBMISSIONS DATE
PROJECT NAME
TYPICAL
ROOF DETAILS
C op yr ig ht
Ke nd ra C
. T ho m ps on A rc hi te ct s, P
.C
1 BID & PLAN REVIEW SET 2/12/2025
ESD
LUDINGTON, MI
WEST SHORE
HVAC UPGRADE PROJECTS
2130 W. U.S. 10
ROOF REPLACEMENT &
NO SCALEA200
3 DRAIN DET.
ROOF
NO SCALEA200
2 DETAIL
CURB
NO SCALEA200
7 DETAIL
VENT PIPE
NO SCALEA200
6 PIPE DETAIL
TYPICAL
NO SCALEA200
5 WALL DETAIL
NO SCALEA200
4 EDGE DETAIL
TYPICAL
FEB 2025
KT-22025002
TYPICAL
NO SCALEA200
1 ROOF DETAIL
WALL TO
File details come from the government source that posted it. Updated .