22-00654-00-RS_Plans.pdf
PDF 25 MB Posted
- Solicitation number
- FY2025-ITB-113
- Issued by
- Champaign County, Illinois
About this file
This document is a detailed roadway lighting plan for the City of Urbana, Illinois, specifically for the Springfield Avenue resurfacing project (Section 22-00654-00-RS). The project involves replacing existing roadway lighting infrastructure from Coler Avenue to McCullough Street, including the installation of 10 new aluminum light poles with 30-foot heights and 10-foot davit arms, mounting new LED luminaires, installing a new lighting controller (#028), and replacing underground electrical conduits and conductors. The plan includes comprehensive electrical details such as junction box locations, conductor specifications, and a complete bill of materials covering items like underground conduit, electric cables, light pole foundations, and luminaire installations.
The electrical work will conform to the 2020 National Electrical Code and IDOT standards, with specific requirements for conduit installation, grounding, and electrical conductor management. The contractor will be responsible for obtaining necessary permits, including a City of Urbana Electrician License, and must coordinate inspections with the city. The project involves removing existing lighting units, some of which will be salvaged, and installing a new electrical system with four lighting circuits. The lighting controller will feature a 100A, 120/240V panelboard, astronomical time clock, lighting contactors, and will maintain the existing Ameren Illinois electrical service, demonstrating a comprehensive approach to updating the area's street lighting infrastructure.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
March 3
March 3
STA. 0+00 TO STA. 43+67
LOCATION(S):
MIXTURE USE(S):
PG:
DESIGN AIR VOIDS:
MIXTURE COMPOSITION:
(MIXTURE GRADATION)
FRICTION AGGREGATE:
QUALITY MANAGEMENT PROGRAM:
SUBLOT SIZE:
MIXTURE WEIGHT (LBS/SQ YD/IN):
ALL STREETS
HMA MIXTURE REQUIREMENTS
MIX D
SURFACE
SBS PG 70-20
N/A
QC/QA
4.0% @ NDESIGN=70
IL-9.5
ALL STREETS
N/A
BINDER
SBS PG 70-20
N/A
QC/QA
4.0% @ NDESIGN=70
IL-9.5FG
2 7
X
X
X
Δ
Δ
NOTE:
1. PROVIDE POSITIVE DRAINAGE ON TREADS.
2. NEW STEPS TO BE MEASURED AND PAID FOR AS CONCRETE STEPS.
3. REINFORCEMENT BARS WILL NOT BE MEASURED AND PAID FOR
SEPARATELY. THE COST OF REINFORCEMENT BARS SHALL BE
INCLUDED IN THE UNIT COST OF CONCRETE STEPS.
4. TREADS SHALL BE BROOM FINISHED.
EXISTING PROPOSED DESCRIPTION
D.S.
FM
GN
H
LS
M
P
PED
PRP
SP
TRAN
WS
WL
LL
RL
PL
EP
SW
A
ROADWAY LED LUMINAIRE ("L1" INDICATES LUMINAIRE TYPE, SEE SPECIAL
PROVISIONS FOR DESCRIPTION OF LUMINAIRE TYPE) MOUNTED ON 10' DAVIT
ARM MOUNTED ON 30' ALUMINUM LIGHT POLE MOUNTED TO METAL HELIX TYPE
FOUNDATION.
ROADWAY OR PEDESTRIAN LUMINAIRE
PORTLAND CEMENT CONCRETE HANDHOLE
PROPOSED LIGHTING CONTROLLER (# AS NOTED)
COMPOSITE TYPE JUNCTION BOX, SPECIAL (12"W x 12"L x 12"D)
2" COILABLE NONMETALLIC CONDUIT SCH 40, AUGURED
(CONDUIT UNDER PAVEMENT TO BE SCH 80)
2" PVC CONDUIT, TRENCHED
UNDERGROUND CONDUIT
OVERHEAD ELECTRICAL CONDUCTORS
ROADWAY LIGHTING CONDUIT/CONDUCTORS
LEGEND ROADWAY LIGHTING LEGEND
1. ALL ELECTRICAL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE 2020 NATIONAL ELECTRICAL CODE, THE IDOT "STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION", AND ALL APPLICABLE LOCAL
ORDINANCES.
2. THE CONTRACTOR SHALL FURNISH ALL MATERIALS FOR A COMPLETE AND WORKABLE SYSTEM.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS AND FOR PROVIDING ALL
SUPERVISION, LABOR, MATERIAL AND TOOLS FOR THE PROJECT. CONTRACTOR SHALL OBTAIN CITY OF URBANA ELECTRICIAN LICENSE PRIOR TO START OF WORK. CONTRACTOR SHALL COORDINATE INSPECTION OF WORK WITH
THE CITY OF URBANA.
4. ALL LOCATIONS AND DIMENSIONS SHOWN ARE APPROXIMATE. THE CONTRACTOR SHALL FIELD VERIFY ALL
EQUIPMENT LOCATIONS AND EQUIPMENT DIMENSIONS.
5. ALL CONDUITS WITH WIRING SHALL BE PROVIDED WITH AN INSULATED COPPER GROUNDING CONDUCTOR SIZED AS
NOTED ON PLANS AND IN ACCORDANCE WITH THE 2020 NATIONAL ELECTRICAL CODE.
6. ALL GROUNDING CONDUCTORS SHALL BE BONDED TOGETHER IN ALL HANDHOLES AND JUNCTION BOXES. (SEE
DETAILS)
7. ALL SERVICE LATERAL CONDUITS SHALL BE SCHEDULE 40 PVC EXCEPT ALL ELBOWS AND VERTICAL RISERS SHALL BE RIGID GALVANIZED STEEL. ALL ELBOWS SHALL BE LONG RADIUS TYPE. CONTRACTOR SHALL VERIFY AND
COMPLY WITH ALL AMEREN ILLINOIS REQUIREMENTS FOR THE SERVICE INSTALLATIONS.
8. ALL LIGHTING CIRCUIT CONDUITS SHALL BE SCHEDULE 40 EXCEPT CONDUITS INSTALLED BELOW PAVEMENT SHALL
BE SCHEDULE 80.
9. CONDUIT ROUTING SHOWN IS SCHEMATIC ONLY. CONTRACTOR SHALL COORDINATE EXACT ROUTING AND INSTALLATION WITH ALL OTHER SITE WORK BEING PERFORMED. COORDINATE ALL POLE LOCATIONS WITH
ENGINEER IN THE FIELD.
10. PROVIDE PULLSTRING IN ALL CONDUITS, INCLUDING THOSE CONDUITS WITH CONDUCTORS INSTALLED. THE PULL STRING SHALL BE INCLUDED IN THE COST OF THE CONDUITS AND NO ADDITIONAL COMPENSATION WILL BE
ALLOWED.
11. THE CONTRACTOR SHALL TAG ALL ELECTRICAL CONDUCTORS (PHASE CONDUCTORS, NEUTRALS, AND GROUNDS) WITH PERMANENT TAGS. EACH CONDUCTOR SHALL BE TAGGED IN ALL CONCRETE HANDHOLES, JUNCTION BOXES, AND POLE HANDHOLES. THE TAG SHALL INDICATE THE LIGHTING CONTROLLER AND CIRCUIT NUMBER FROM WHICH
THE CONDUCTORS ORIGINATE.
12. ALL CONDUITS SHALL BE 30" BELOW FINAL GRADE UNLESS OTHERWISE DIRECTED BY THE ENGINEER. CONTRACTOR IS RESPONSIBLE FOR REPAIR TO ALL UNDERGROUND UTILITIES DAMAGED DURING INSTALLATION OF ROADWAY
LIGHTING AND FEEDER SYSTEMS.
13. SERVICE GROUND RODS SHALL BE 3/4" DIAMETER x 10'-0" LONG COPPER CLAD STEEL. GROUND RODS AT POLES SHALL BE 5/8" DIAMETER X 10'-0" LONG. GROUNDING ELECTRODE CONDUCTORS SHALL BE #4 SOLID COPPER AND SHALL BE CONNECTED WITH HYDRAULIC CRIMP TYPE CONNECTIONS TO GROUNDING ELECTRODE. GROUND RODS
SHALL BE INSTALLED AT LIGHTING CONTROLLER, HANDHOLES AND JUNCTION BOXES.
14. POLE WIRING WILL NOT BE PAID FOR SEPARATELY BUT SHALL BE INCLUDED WITH THE LUMINAIRE PER ARTICLE
821.03 OF THE STANDARD SPECIFICATIONS.
15. WHERE EXISTING CONDUCTORS ARE TO BE ABANDONED IN PLACE, THE CONDUCTORS SHALL BE DISCONNECTED
AND ISOLATED FROM EXISTING CONDUCTORS WHICH ARE TO REMAIN ENERGIZED.
16. THE CONTRACTOR SHALL USE CARE IN CONSTRUCTING THE LIGHT POLES THAT ARE NEAR TRENCH EXCAVATIONS FOR STORM SEWERS AND OTHER UTILITIES. THE CONTROLLED LOW-STRENGTH MATERIAL SHALL BE BLOCKED OUT AT THE CONCRETE FOUNDATION LOCATIONS TO ALLOW FOR THEIR LATER CONSTRUCTION AS DIRECTED BY THE
ENGINEER.
17. THE EXISTING LIGHTING UNITS (LUMINAIRES AND POLES) THAT ARE NOTED TO BE SALVAGED SHALL REMAIN THE PROPERTY OF THE CITY OF URBANA, AND SHALL BE MOVED TO AND STORED AT A LOCATION DESIGNATED BY THE
ENGINEER FOR PICK UP BY THE CITY'S FORCES.
18. CONDUITS ARE INDICATED AS TRENCHED OR AUGERED FOR INFORMATION PURPOSES. ALL CONDUIT WILL BE PAID AT THE CONTRACT UNIT PRICE PER FOOT FOR UNDERGROUND CONDUIT OF THE TYPE AND SIZE SPECIFIED.
19. JUNCTION BOXES SHALL INCLUDE THE INTENDED USE CAST INTO THE COVER. SEE SPECIAL PROVISIONS.
ELECTRICAL GENERAL NOTES
CIRCUIT DESIGNATION SCHEME
40+06.0
20.5' LT
028A929
POLE NUMBERLIGHTING CONTROLLER
CIRCUIT
POLE LOCATION
NOTE:
THE CONTRACTOR SHALL PROVIDE A PERMANENT
STICKER INSIDE HAND HOLE OF EACH LIGHT POLE
INDICATING THE LIGHTING CONTROLLER, CIRCUIT
AND POLE NUMBER.
028A
LIGHTING CONTROLLER AND CIRCUIT
NUMBER OF CONDUCTORS OF THIS SIZE
IN CONDUIT.
* INDICATES INCLUDES GROUND
CONDUCTOR SIZE FOR COPPER
CONDUCTORS IN AWG
CONDUCTOR SYMBOL SCHEME
41+20.2
21.0' RT
028JB22
JUNCTION BOX LOCATION
JUNCTION BOX NUMBERLIGHTING CONTROLLER
JUNCTION BOX DESIGNATION SCHEME
CODE
NUMBER
81028350 81028750
UNDERGROUND CONDUIT, PVC, 2" DIA. FOOT
FOOT
CODE
NUMBER
TOTAL
QUANTITY
ITEM
UNDERGROUND CONDUIT, COILABLE NONMETALLIC, 2" DIA.
81702110 900ELECTRIC CABLE IN CONDUIT, 600V (XLP-TYPE USE) 1/C NO.10
81702120 5280ELECTRIC CABLE IN CONDUIT, 600V (XLP-TYPE USE) 1/C NO.8
81702155 120ELECTRIC CABLE IN CONDUIT, 600V (XLP-TYPE USE) 1/C NO.1
84200500 3REMOVAL OF LIGHTING UNIT, SALVAGE
84200600 7REMOVAL OF LIGHTING UNIT, NO SALVAGE
84200804 10REMOVAL OF POLE FOUNDATION
84500110 1REMOVAL OF LIGHTING CONTROLLER
84500120 1REMOVAL OF ELECTRIC SERVICE INSTALLATION
X8040102 1ELECTRIC SERVICE INSTALLATION, SPECIAL
X8130110 12JUNCTION BOX, SPECIAL
X8250505 1LIGHTING CONTROLLER, SPECIAL
X8360120 10LIGHT POLE FOUNDATION, SPECIAL METAL HELIX TYPE
XX008068 10LUMINAIRE INSTALLATION, TYPE 1
BILL OF MATERIALS
FOOT
FOOT
FOOT
EACH
EACH
EACH
EACH
EACH
EACH
EACH
EACH
EACH
EACH
83000400 10LIGHT POLE, ALUMINUM, 30 FT, M.H., 10 FT. DAVIT ARM EACH
100'0' 50'
ROADWAY LIGHTING OVERVIEW PLAN
SPRINGFIELD AVE.
N . C
O
LE
R A
VE
S. CO
LER AVE.
M cCULLO
UG
H ST.
W. STOUGHTON ST.
028C943
CONTROLLER #028
LIGHTING
028A933
028A931 028A929
028A927 028A926
028A925
028C928
028C932
028D934
SPRINGFIELD AVE.
SPRINGFIELD AVE.
M
AT
CH
LI
NE
ST
A.
8+
.0
37+52.8
19.0' LT
028A933
37+49.8
19.0' LT
028JB1
36+06.9
19.0' LT
028C943
36+03.9
19.0' LT
028JB7
100+80.0
22.5' RT
028JB8
100+83.0
22.5' RT
028D934
100+80.0
22.5' RT
028JB10
38+32.6
21.0' RT
028C932
36+20.5
22.5' RT
028JB9
028C
028C
028C
028A
028B
KEYNOTES
1. EXISTING LIGHTING UNIT (POLE, FOUNDATION, AND LUMINAIRE) TO BE
REMOVED COMPLETE.
2. EXISTING UNDERGROUND LIGHTING CONDUCTORS TO BE CUT-OFF BELOW
GRADE AND ABANDONED IN PLACE. ANY ABANDONED CONDUCTORS THAT
INTERFERE WITH THE PROPOSED IMPROVEMENTS SHALL BE REMOVED AT
THE POINT OF CONFLICT, AND NO ADDITIONAL COMPENSATION WILL BE
ALLOWED.
3. EXISTING LIGHTING UNIT (POLE AND LUMINAIRE) AND EXISTING LIGHTING
CONDUCTORS TO REMAIN AND BE REFED FROM NEW CIRCUIT. SEE
KEYNOTE 4.
4. INTERCEPT EXISTING LIGHTING CONDUCTORS TO EXISTING LIGHTING POLE
IN NEW JUNCTION BOX.
5. EXISTING LIGHTING CONTROLLER AND METER TO BE REMOVED AND
REPLACED WITH NEW LIGHTING CONTROLLER AND METER. EXISTING
AMEREN ILLINOIS SERVICE TO REMAIN AND BE REUSED. INTERCEPT AND
EXTEND SERVICE CONDUCTORS AS NEEDED.
6. EXISTING AMEREN ILLINOIS SERVICE RISER POLE TO REMAIN.
7. BORE 2" CONDUIT UNDER ROAD.
8. PROVIDE SPARE 2" CONDUIT FROM CONTROLLER TO JUNCTION BOX 028JB1.
9. PROVIDE SPARE 2" CONDUIT FROM CONTROLLER TO JUNCTION BOX 028JB7.
CIRCUIT DESIGNATION SCHEME
40+06.0
20.5' LT
028A929
POLE NUMBERLIGHTING CONTROLLER
CIRCUIT
POLE LOCATION
NOTE:
THE CONTRACTOR SHALL PROVIDE A PERMANENT
STICKER INSIDE HAND HOLE OF EACH LIGHT POLE
INDICATING THE LIGHTING CONTROLLER, CIRCUIT
AND POLE NUMBER.
028A
LIGHTING CONTROLLER AND CIRCUIT
NUMBER OF CONDUCTORS OF THIS SIZE
IN CONDUIT.
* INDICATES INCLUDES GROUND
CONDUCTOR SIZE FOR COPPER
CONDUCTORS IN AWG
CONDUCTOR SYMBOL SCHEME
41+20.2
21.0' RT
028JB22
JUNCTION BOX LOCATION
JUNCTION BOX NUMBERLIGHTING CONTROLLER
JUNCTION BOX DESIGNATION SCHEME
37+25.4
21.5' LT
CONTROLLER #028
LIGHTING
3028D935
028C9443
028C9453
028D
7 3
028D
* 2
028C 028D
NOTES
1. EXISTING OVERHEAD ELECTRICAL/UTILITY POLES AND LINES TO REMAIN.
2. LIGHT POLE LOCATIONS MAY BE ADJUSTED IN THE FIELD AS DIRECTED BY
THE ENGINEER TO AVOID UTILITY CONFLICTS, AND NO ADDITIONAL
COMPENSATION WILL BE ALLOWED.
SPRINGFIELD AVE.
N . C
O
LE
R A
VE
S. CO
LER AVE.
SPRINGFIELD AVE.
40'0' 20'
L1
L1 L1
L1
KEYNOTES
1. EXISTING LIGHTING UNIT (POLE, FOUNDATION, AND LUMINAIRE) TO BE
REMOVED COMPLETE.
2. EXISTING UNDERGROUND LIGHTING CONDUCTORS TO BE CUT-OFF BELOW
GRADE AND ABANDONED IN PLACE. ANY ABANDONED CONDUCTORS THAT
INTERFERES WITH THE PROPOSED IMPROVEMENTS SHALL BE REMOVED AT
THE POINT OF CONFLICT, AND NO ADDITIONAL COMPENSATION WILL BE
ALLOWED.
3. EXISTING LIGHTING UNIT (POLE AND LUMINAIRE) AND EXISTING LIGHTING
CONDUCTORS TO REMAIN AND BE REFED FROM NEW CIRCUIT. SEE
KEYNOTE 4.
4. INTERCEPT EXISTING LIGHTING CONDUCTORS TO EXISTING LIGHTING POLE
IN NEW JUNCTION BOX.
M
AT
CH
LI
NE
ST
A.
8+
.0
41+23.2
21.0' RT
028C928
41+20.2
21.0' RT
028JB1239+86.5
21.0' RT
028JB11 3
028C
028C
3028C930
40+09.0
20.5' LT
028JB3
40+06.0
20.5' LT
028A929
3 028B947
028B9483
3028B946
39+12.8
21.0' LT
028A93139+09.8
21.0' LT
028JB2
028A
42+21.0
26.5' LT
028A927
42+21.0
26.5' LT
028JB4
43+06.5
27.5' LT
028A926
43+03.5
27.5' LT
028JB5
43+69.7
29.0' LT
028A925
43+66.7
29.0' LT
028JB6
028A
028A
028A9513
028A
028A
CIRCUIT DESIGNATION SCHEME
40+06.0
20.5' LT
028A929
POLE NUMBERLIGHTING CONTROLLER
CIRCUIT
POLE LOCATION
NOTE:
THE CONTRACTOR SHALL PROVIDE A PERMANENT
STICKER INSIDE HAND HOLE OF EACH LIGHT POLE
INDICATING THE LIGHTING CONTROLLER, CIRCUIT
AND POLE NUMBER.
028A
LIGHTING CONTROLLER AND CIRCUIT
NUMBER OF CONDUCTORS OF THIS SIZE
IN CONDUIT.
* INDICATES INCLUDES GROUND
CONDUCTOR SIZE FOR COPPER
CONDUCTORS IN AWG
CONDUCTOR SYMBOL SCHEME
41+20.2
21.0' RT
028JB22
JUNCTION BOX LOCATION
JUNCTION BOX NUMBERLIGHTING CONTROLLER
JUNCTION BOX DESIGNATION SCHEME
028B
028B
NOTES
1. EXISTING OVERHEAD ELECTRICAL/UTILITY POLES AND LINES TO REMAIN.
2. LIGHT POLE LOCATIONS MAY BE ADJUSTED IN THE FIELD AS DIRECTED BY
THE ENGINEER TO AVOID UTILITY CONFLICTS, AND NO ADDITIONAL
COMPENSATION WILL BE ALLOWED.
SPRINGFIELD AVE.
M cCULLO
UG
H ST.
4 4
4 2
40'0' 20'
L1
L1
L1
L1
L1
L1
(SALVAGE)
(SALVAGE)
(SALVAGE)
LIGHTING CONTROLLER #028
NO SCALE
DIAGRAMMATIC ASSEMBLY DETAIL
CONTROL CABINET, FOUNDATION AND
FRONT VIEW
(LOOKING SOUTH)
SIDE VIEW
(LOOKING WEST)
100A, 120/240V, 1Ø, 30 CIRCUIT PANELBOARD (INTERIOR ONLY,
NO PANEL TUB), QUANTITIES OF BREAKERS AS SHOWN IN
PANELBOARD SCHEDULES.
HAND-OFF-PHOTOCELL - TIMER SELECTOR SWITCH WITH LEGEND PLATE.
120 VAC, 20A, 1P PLUNGER TYPE SWITCH FOR CONTROLLER LIGHT,
DOOR ACTIVATED.
LIGHTING CONTROLLER #028 BILL OF MATERIALS
INCANDESCENT LIGHT FIXTURE WITH CLEAR GLOBE AND
PROTECTIVE GUARD. PROVIDE 60WATT, 130VAC LAMP.
ASTRONOMICAL TIME CLOCK WITH BATTERY MEMORY BACKUP
(CAPACITANCE BACKUP IS ACCEPTABLE IF AVAILABLE).
ONE CIRCUIT TO CONTROL LIGHTING CONTACTORS.
DUPLEX RECEPTACLES, 120VAC, 20A, GFCI TYPE.
TERMINAL STRIPS. QUANTITY AS REQUIRED FOR INCOMING WIRING
PLUS 100% SPARE TERMINALS. PROVIDE SEPARATE TERMINAL
STRIPS FOR POWER, NEUTRAL AND GROUND WIRING AS REQUIRED.
LIGHTING CONTACTOR (LC-A, LC-B, LC-C, LC-D), 30A, 240VAC,
4 POLE, 120 VAC ELECTRICALLY HELD COIL. PROVIDE SPACE
FOR ADDITIONAL CONTACTORS.
SURGE ARRESTOR.
CONTROL WIRING TERMINAL BLOCK.
(1) 2" RGS CONDUIT
WITH 3#1
INSTALLATION
MOUNTING BOARD
CONTROLLER
CABINET
CONTRACTOR SHALL PROVIDE UTILITY
METER BASE. COORDINATED EXACT
REQUIREMENTS WITH AMEREN ILLINOIS
EXOTHERMIC WELD
CONTRACTOR SHALL PROVIDE UTILITY
METER BASE. COORDINATE EXACT
REQUIREMENTS WITH AMEREN ILLINOIS
2P, 100A, NEMA 4X SS FUSED DISCONNECT
SWITCH WITH 100A FUSES. SWITCH SHALL
BE LOCKABLE IN OPEN AND CLOSED POSITION
CONTROLLER
CABINET
(1) 2" RGS CONDUIT
WITH 3#1
(1) 2" RGS CONDUIT
WITH 3#1, 1#4G
CONCRETE
FOUNDATION
(TYPE D. SEE
STD. 878001)
FINISHED GRADE LINE
(1) 1" PVC CONDUIT
WITH 1#4 GROUND
3 4
1"
CONCRETE
FOUNDATION
(TYPE D. SEE
STD. 878001)
6"6"
PROVIDE (2) 2" PVC CONDUITS INTO CABINET FOR ROADWAY
LIGHTING CIRCUITS:
CONDUIT 1 - 4#8, 1#8G (LTG. CKTS. A & B)
CONDUIT 2 - EMPTY SPARE FOR FUTURE USE
CONDUITS SHALL BE ROUTED TO HANDHOLE AS
SHOWN ON THE PLANS
3/4" DIA. X 10' COPPER
CLAD GROUND ROD
#4 BARE GROUND WIRE
(1) 1" PVC CONDUIT
FOR GROUND WIRE
(1) 2" SCHEDULE 80 CONDUIT
WITH 3#1 TO UTILITY POLE
FINISHED GRADE LINE
PHOTOCELL SWITCH WITH LOCKING TYPE RECEPTACLE
AND INTEGRAL SURGE ARRESTORS. PHOTOCELL SHALL BE
CABINET MOUNTED AND SHIELDED FROM SURROUNDING
LIGHT SOURCES, WITH TIME DELAY RELAY TO PREVENT
NUISANCE SWITCHING. (SEE PHOTOCELL DETAIL)
1 11
CLEAR GLASS LENS,
COVER, & NEOPRENE
GASKET BETWEEN
COVER & CABINET
PHOTOCELL
(LOCATED INSIDE
CONTROL CABINET)
14" STAINLESS STEEL
BOLTS WITH
SELF-LOCKING NUTS
18" x 6" x 8"
ALUMINUM SHEET
6"
3" HOLE IN SIDE
OF CAST CABINET
14" STAINLESS STEEL BOLT
WITH ALUMINUM SLEEVE
AS STANDOFF. USE
SELF-LOCKING NUTS.
2"
PHOTOCELL DETAIL
NO SCALE
PROVIDE (2) 2" PVC CONDUITS INTO CABINET FOR ROADWAY
LIGHTING CIRCUITS:
CONDUIT 1 - 4#8, 1#8G (LTG. CKTS. C & D)
CONDUIT 2 - EMPTY SPARE FOR FUTURE USE
CONDUITS SHALL BE ROUTED TO HANDHOLE AS
SHOWN ON THE PLANS
NH
120V
120V H20A/1P
PHOTOCELL
TIMECLOCK
HAND TIMECLOCK
OFF PHOTOCELL
"ROADWAY
LIGHTING"
LC-A
LC-B
LC-C
LC-D
GFI
00X0
000X
X000
CONTROLLER
LIGHT AND SWITCH
NOTE:
GROUND WIRE NOT SHOWN FOR CLARITY. CONTRACTOR SHALL GROUND
ALL EQUIPMENT IN THE LIGHTING CONTROL CABINET AS REQUIRED BY
THE 2020 NATIONAL ELECTRICAL CODE.
LIGHTING CONTROLLER #028 CONTROL DIAGRAM
NO SCALE
TO AMEREN IP
TRANSFORMER
100 AMP
MAIN BREAKER
30 AMP
2 POLE
30 AMP
2 POLE
30 AMP
2 POLE
30 AMP
2 POLE
30 AMP
2 POLE
20 AMP
1 POLE
20 AMP
1 POLE
TO LIGHTING
CIRCUIT A
TO LIGHTING
CIRCUIT B
TO LIGHTING
CIRCUIT C
TO LIGHTING
CIRCUIT D
CONTROL
CIRCUIT
CONTROLLER
LIGHT AND GFI
LIGHTING
CONTACTOR
LC-A
LIGHTING
CONTACTOR
LC-B
LIGHTING
CONTACTOR
LC-C
LIGHTING
CONTACTOR
LC-D
SURGE
ARRESTOR
LIGHTING CONTROLLER #028
LIGHTING CONTROLLER #028 ELECTRICAL ONE-LINE DIAGRAM
LIGHTING CONTROLLER #028 PANELBOARD SCHEDULE
INSTALLATION DETAIL
LIGHT POLE FOUNDATION
A
D
POLE HANDHOLE
POLE/ARM DIAGRAMMATIC ONLY
B
C
MOUNTING PLATE
AT FINAL GRADE
KEYNOTES
A METAL FOUNDATION IN ACCORDANCE WITH STANDARD 836001 AND THE SPECIAL PROVISIONS.
B LED LUMINAIRE AS SHOWN ON THE PLANS.
C CONDUIT AND CABLE TO GULBOX JUNCTOIN OR JUNCTION BOX SPECIAL AS SHOWN ON THE PLANS.
D ALUMINUM LIGHT POLE AS SHOWN ON THE PLANS.
WITH EQUIPMENT GROUNDING CONDUCTOR
NO SCALE
2 WIRE - 240 VAC (UNDERGROUND CONDUCTORS)
DETAIL "A"
DOUBLE POLE
POLE FOUNDATION DETAIL
NO SCALE
VENTILATING SCREEN,
STAINLESS STEEL
FOUNDATION AS
SHOWN IN PLANS
LIGHT POLE
TYPICAL GROUNDING CONNECTIONS
NO SCALE
HEX HEAD BOLT
12" x 1 12" - 13 TPI
#4 AWG EQUIPMENT
GROUNDING CONDUCTOR
FROM THE GROUNDING
ELECTRODE
COMPRESSION CONNECTOR EQUAL
TO BURNDY TYPE YA4C-N-45
NUT
LOCK WASHER
FLAT WASHER
FACTORY STUD WELDED
TO POLE
NOTE: NUT, BOLT, AND WASHERS SHALL BE STAINLESS STEEL.
GROUNDING ROD INSTALLATION DETAIL
NO SCALE
EQUIPMENT GROUNDING
CONDUCTOR FROM THE
GROUNDING ELECTRODE
THRU THE COMPRESSION
CONNECTOR.
LOCKNUT WASHER
NUT
FACTORY WELDED
BRACKET TO POLE
COMPRESSION CONNECTOR EQUAL
TO BURNDY TYPE YA4C-N-
HEX HEAD BOLT
12" x 1 12" - 13 TPI
FLAT WASHER
NEMA APPROVED
GROUND CONNECTOR
12" - 13 UNC STUD,
SILICON BRONZE
12" NUT OR THREADED
FACTORY WELDED BRACKET
TO POLE SHAFT
JUNCTION BOX INSTALLATION DETAIL
NO SCALE
1-1/C #6, 600V, XLP-TYPE
USE (GROUND)
2-1/C #6 ELECTRIC CABLES AND
1-1/C #6 ELECTRICAL CABLE GRND.,
600V, XLP-USE
COMPRESSION CONNECTOR
2" DIA. COILABLE
NONMETALIC CONDUIT
6" TOPSOIL ABOVE COMPACTED
CLAY SUBSOIL OR CONCRETE
SURFACE
COMPACTED CA-6 DOWN
TO UNDISTURBED EARTH,
MINIMUM 6" DEPTH
2" DIA. PVC CONDUIT
IN TRENCH
COMPACTED CLAY SUBSOIL
AROUND INCOMING CONDUITS
#10 AWG EQUIPMENT
GROUNDING CONDUCTOR
TO ROADWAY LUMINAIRE
TYPICAL GROUNDING
CONNECTION - SEE DETAIL
APPROVED COMPRESSION TYPE
CONNECTOR FOR EQUIPMENT
GROUNDING CONDUCTORS
AWG #4 (MIN.) BARE EQUIPMENT
GROUNDING CONDUCTOR. NOTE:
THIS WIRE SHALL BE CONTINUOUS
WITHOUT SPLICES FROM THE
GROUNDING ELECTRODE TO THE
EQUIPMENT GROUNDING
CONDUCTOR SPLICE CONNECTOR
U.S.E.RATED XLP INSULATED
COPPER STRANDED EQUIPMENT
GROUNDING CONDUCTORS FROM
SYSTEM RACEWAY
EXOTHERMICALLY WELDED TO
GROUNDING ELECTRODE
UNGROUNDED CONDUCTORS TO
ROADWAY LUMINAIRE SHALL BE #10
AWG, COPPER STRANDED, U.S.E.
RATED, XLP INSULATED. CONNECT
TO ROADWAY LUMINIARE WITH
CRIMP TYPE CONNECTORS EQUAL
TO 3M TYPE MV.
CIRCUIT TAGS, BOTH SIDES
OF ALL FUSES (TYPICAL)
IN LINE FUSE ASSEMBLY
TWO POLE, 600 VAC, WITH
5 AMP FNQ FUSES (SEE
DETAIL "A") TAPE AND
VARNISH CRIMPED END
FERRULES FUSE HOLDER
EQUAL TO BUSSMAN TYPE
HEX-A-A WITH INSULATING
BOOTS. (TYPICAL)
LARGE HANDHOLE & COVER
U.S.E.RATED XLP INSULATED
COPPER STRANDED UNGROUNDED
CIRCUIT CONDUCTORS FROM
SYSTEM RACEWAY
COMPOSITE CONCRETE JUNCTION
BOX APPROX. 12"X12"X12"
GROUND ROD
EXCAVATE TO UNDISTURBED
SUBSOIL AND BACKFILL
UNDER BOX WITH CA-6
LI
G
H T
PO
LE
F O
U N
D
AT
IO
N
COMPOSITE CONCRETE
JUNCTION BOX
HYDRAULIC CRIMP
CONNECTION
SPLICE CABLES
2-1/C #6, 600V, XLP-USE
SPLIT BOLT
CONNECTOR
58 X 10' COPPER CLAD STEEL
GROUND ROD INCIDENTAL TO
JUNCTION BOX
G
RE
EN
BL
AC
K
BL
AC
K
G
RE
EN
RE
D
RE
D
BA
R
E
2" DIA. PVC CONDUIT
IN TRENCH
MOUNT POLE TO
FOUNDATOIN USING A
BREAKAWAY COUPLING
SYSTEM
E MOUNT POLE TO METAL FOUNDATION USING A BASE BREAKAWAY COUPLING SYSTEM.
E
| Sheets and Views |
| 1 COVER SHEET |
| 2 SUMMARY OF QUANTITIES |
| 3 SCHEDULE OF QUANTITIES |
| 4 SCHEDULE OF QUANTITIES |
| 5 EXISTING TYPICAL SECTIONS |
| 6 PROPOSED TYPICAL SECTIONS |
| 7 DETOUR ROUTE |
| 8 REMOVALS PLAN |
| 9 PLAN AND PROFILE |
| 10 PLAN AND PROFILE |
| 11 P.C.C. PAVEMENT GRADING AND DRAINAGE |
| 12 SLAB OVER CULVERT - STRUCTURE 6110 |
| 13 JOINTING PLAN |
| 14 PAVEMENT MARKINGS |
| 15 ADA CURB RAMP DETAILS |
| 16 BOX CULVERT SECTION - STRUCTURE 6110 |
| 17 MISCELLANEOUS DETAILS |
| 18 MISCELLANEOUS DETAILS |
| 19 EXISTING BOX CULVERT PLANS |
File details come from the government source that posted it. Updated .