22-00654-00-RS_Plans.pdf

PDF 25 MB Posted

Attached to
Springfield Avenue (Coler to McCullough) Resurfacing, Section 22-00654-00-RS
Solicitation number
FY2025-ITB-113
Issued by
Champaign County, Illinois

About this file

This document is a detailed roadway lighting plan for the City of Urbana, Illinois, specifically for the Springfield Avenue resurfacing project (Section 22-00654-00-RS). The project involves replacing existing roadway lighting infrastructure from Coler Avenue to McCullough Street, including the installation of 10 new aluminum light poles with 30-foot heights and 10-foot davit arms, mounting new LED luminaires, installing a new lighting controller (#028), and replacing underground electrical conduits and conductors. The plan includes comprehensive electrical details such as junction box locations, conductor specifications, and a complete bill of materials covering items like underground conduit, electric cables, light pole foundations, and luminaire installations.

The electrical work will conform to the 2020 National Electrical Code and IDOT standards, with specific requirements for conduit installation, grounding, and electrical conductor management. The contractor will be responsible for obtaining necessary permits, including a City of Urbana Electrician License, and must coordinate inspections with the city. The project involves removing existing lighting units, some of which will be salvaged, and installing a new electrical system with four lighting circuits. The lighting controller will feature a 100A, 120/240V panelboard, astronomical time clock, lighting contactors, and will maintain the existing Ameren Illinois electrical service, demonstrating a comprehensive approach to updating the area's street lighting infrastructure.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

March 3

March 3

STA. 0+00 TO STA. 43+67

LOCATION(S):

MIXTURE USE(S):

PG:

DESIGN AIR VOIDS:

MIXTURE COMPOSITION:

(MIXTURE GRADATION)

FRICTION AGGREGATE:

QUALITY MANAGEMENT PROGRAM:

SUBLOT SIZE:

MIXTURE WEIGHT (LBS/SQ YD/IN):

ALL STREETS

HMA MIXTURE REQUIREMENTS

MIX D

SURFACE

SBS PG 70-20

N/A

QC/QA

4.0% @ NDESIGN=70

IL-9.5

ALL STREETS

N/A

BINDER

SBS PG 70-20

N/A

QC/QA

4.0% @ NDESIGN=70

IL-9.5FG

2 7

X

X

X

Δ

Δ

NOTE:

1. PROVIDE POSITIVE DRAINAGE ON TREADS.

2. NEW STEPS TO BE MEASURED AND PAID FOR AS CONCRETE STEPS.

3. REINFORCEMENT BARS WILL NOT BE MEASURED AND PAID FOR

SEPARATELY. THE COST OF REINFORCEMENT BARS SHALL BE

INCLUDED IN THE UNIT COST OF CONCRETE STEPS.

4. TREADS SHALL BE BROOM FINISHED.

EXISTING PROPOSED DESCRIPTION

D.S.

FM

GN

H

LS

M

P

PED

PRP

SP

TRAN

WS

WL

LL

RL

PL

EP

SW

A

ROADWAY LED LUMINAIRE ("L1" INDICATES LUMINAIRE TYPE, SEE SPECIAL

PROVISIONS FOR DESCRIPTION OF LUMINAIRE TYPE) MOUNTED ON 10' DAVIT

ARM MOUNTED ON 30' ALUMINUM LIGHT POLE MOUNTED TO METAL HELIX TYPE

FOUNDATION.

ROADWAY OR PEDESTRIAN LUMINAIRE

PORTLAND CEMENT CONCRETE HANDHOLE

PROPOSED LIGHTING CONTROLLER (# AS NOTED)

COMPOSITE TYPE JUNCTION BOX, SPECIAL (12"W x 12"L x 12"D)

2" COILABLE NONMETALLIC CONDUIT SCH 40, AUGURED

(CONDUIT UNDER PAVEMENT TO BE SCH 80)

2" PVC CONDUIT, TRENCHED

UNDERGROUND CONDUIT

OVERHEAD ELECTRICAL CONDUCTORS

ROADWAY LIGHTING CONDUIT/CONDUCTORS

LEGEND ROADWAY LIGHTING LEGEND

1. ALL ELECTRICAL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE 2020 NATIONAL ELECTRICAL CODE, THE IDOT "STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION", AND ALL APPLICABLE LOCAL

ORDINANCES.

2. THE CONTRACTOR SHALL FURNISH ALL MATERIALS FOR A COMPLETE AND WORKABLE SYSTEM.

3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS AND FOR PROVIDING ALL

SUPERVISION, LABOR, MATERIAL AND TOOLS FOR THE PROJECT. CONTRACTOR SHALL OBTAIN CITY OF URBANA ELECTRICIAN LICENSE PRIOR TO START OF WORK. CONTRACTOR SHALL COORDINATE INSPECTION OF WORK WITH

THE CITY OF URBANA.

4. ALL LOCATIONS AND DIMENSIONS SHOWN ARE APPROXIMATE. THE CONTRACTOR SHALL FIELD VERIFY ALL

EQUIPMENT LOCATIONS AND EQUIPMENT DIMENSIONS.

5. ALL CONDUITS WITH WIRING SHALL BE PROVIDED WITH AN INSULATED COPPER GROUNDING CONDUCTOR SIZED AS

NOTED ON PLANS AND IN ACCORDANCE WITH THE 2020 NATIONAL ELECTRICAL CODE.

6. ALL GROUNDING CONDUCTORS SHALL BE BONDED TOGETHER IN ALL HANDHOLES AND JUNCTION BOXES. (SEE

DETAILS)

7. ALL SERVICE LATERAL CONDUITS SHALL BE SCHEDULE 40 PVC EXCEPT ALL ELBOWS AND VERTICAL RISERS SHALL BE RIGID GALVANIZED STEEL. ALL ELBOWS SHALL BE LONG RADIUS TYPE. CONTRACTOR SHALL VERIFY AND

COMPLY WITH ALL AMEREN ILLINOIS REQUIREMENTS FOR THE SERVICE INSTALLATIONS.

8. ALL LIGHTING CIRCUIT CONDUITS SHALL BE SCHEDULE 40 EXCEPT CONDUITS INSTALLED BELOW PAVEMENT SHALL

BE SCHEDULE 80.

9. CONDUIT ROUTING SHOWN IS SCHEMATIC ONLY. CONTRACTOR SHALL COORDINATE EXACT ROUTING AND INSTALLATION WITH ALL OTHER SITE WORK BEING PERFORMED. COORDINATE ALL POLE LOCATIONS WITH

ENGINEER IN THE FIELD.

10. PROVIDE PULLSTRING IN ALL CONDUITS, INCLUDING THOSE CONDUITS WITH CONDUCTORS INSTALLED. THE PULL STRING SHALL BE INCLUDED IN THE COST OF THE CONDUITS AND NO ADDITIONAL COMPENSATION WILL BE

ALLOWED.

11. THE CONTRACTOR SHALL TAG ALL ELECTRICAL CONDUCTORS (PHASE CONDUCTORS, NEUTRALS, AND GROUNDS) WITH PERMANENT TAGS. EACH CONDUCTOR SHALL BE TAGGED IN ALL CONCRETE HANDHOLES, JUNCTION BOXES, AND POLE HANDHOLES. THE TAG SHALL INDICATE THE LIGHTING CONTROLLER AND CIRCUIT NUMBER FROM WHICH

THE CONDUCTORS ORIGINATE.

12. ALL CONDUITS SHALL BE 30" BELOW FINAL GRADE UNLESS OTHERWISE DIRECTED BY THE ENGINEER. CONTRACTOR IS RESPONSIBLE FOR REPAIR TO ALL UNDERGROUND UTILITIES DAMAGED DURING INSTALLATION OF ROADWAY

LIGHTING AND FEEDER SYSTEMS.

13. SERVICE GROUND RODS SHALL BE 3/4" DIAMETER x 10'-0" LONG COPPER CLAD STEEL. GROUND RODS AT POLES SHALL BE 5/8" DIAMETER X 10'-0" LONG. GROUNDING ELECTRODE CONDUCTORS SHALL BE #4 SOLID COPPER AND SHALL BE CONNECTED WITH HYDRAULIC CRIMP TYPE CONNECTIONS TO GROUNDING ELECTRODE. GROUND RODS

SHALL BE INSTALLED AT LIGHTING CONTROLLER, HANDHOLES AND JUNCTION BOXES.

14. POLE WIRING WILL NOT BE PAID FOR SEPARATELY BUT SHALL BE INCLUDED WITH THE LUMINAIRE PER ARTICLE

821.03 OF THE STANDARD SPECIFICATIONS.

15. WHERE EXISTING CONDUCTORS ARE TO BE ABANDONED IN PLACE, THE CONDUCTORS SHALL BE DISCONNECTED

AND ISOLATED FROM EXISTING CONDUCTORS WHICH ARE TO REMAIN ENERGIZED.

16. THE CONTRACTOR SHALL USE CARE IN CONSTRUCTING THE LIGHT POLES THAT ARE NEAR TRENCH EXCAVATIONS FOR STORM SEWERS AND OTHER UTILITIES. THE CONTROLLED LOW-STRENGTH MATERIAL SHALL BE BLOCKED OUT AT THE CONCRETE FOUNDATION LOCATIONS TO ALLOW FOR THEIR LATER CONSTRUCTION AS DIRECTED BY THE

ENGINEER.

17. THE EXISTING LIGHTING UNITS (LUMINAIRES AND POLES) THAT ARE NOTED TO BE SALVAGED SHALL REMAIN THE PROPERTY OF THE CITY OF URBANA, AND SHALL BE MOVED TO AND STORED AT A LOCATION DESIGNATED BY THE

ENGINEER FOR PICK UP BY THE CITY'S FORCES.

18. CONDUITS ARE INDICATED AS TRENCHED OR AUGERED FOR INFORMATION PURPOSES. ALL CONDUIT WILL BE PAID AT THE CONTRACT UNIT PRICE PER FOOT FOR UNDERGROUND CONDUIT OF THE TYPE AND SIZE SPECIFIED.

19. JUNCTION BOXES SHALL INCLUDE THE INTENDED USE CAST INTO THE COVER. SEE SPECIAL PROVISIONS.

ELECTRICAL GENERAL NOTES

CIRCUIT DESIGNATION SCHEME

40+06.0

20.5' LT

028A929

POLE NUMBERLIGHTING CONTROLLER

CIRCUIT

POLE LOCATION

NOTE:

THE CONTRACTOR SHALL PROVIDE A PERMANENT

STICKER INSIDE HAND HOLE OF EACH LIGHT POLE

INDICATING THE LIGHTING CONTROLLER, CIRCUIT

AND POLE NUMBER.

028A

LIGHTING CONTROLLER AND CIRCUIT

NUMBER OF CONDUCTORS OF THIS SIZE

IN CONDUIT.

* INDICATES INCLUDES GROUND

CONDUCTOR SIZE FOR COPPER

CONDUCTORS IN AWG

CONDUCTOR SYMBOL SCHEME

41+20.2

21.0' RT

028JB22

JUNCTION BOX LOCATION

JUNCTION BOX NUMBERLIGHTING CONTROLLER

JUNCTION BOX DESIGNATION SCHEME

CODE

NUMBER

81028350 81028750

UNDERGROUND CONDUIT, PVC, 2" DIA. FOOT

FOOT

CODE

NUMBER

TOTAL

QUANTITY

ITEM

UNDERGROUND CONDUIT, COILABLE NONMETALLIC, 2" DIA.

81702110 900ELECTRIC CABLE IN CONDUIT, 600V (XLP-TYPE USE) 1/C NO.10

81702120 5280ELECTRIC CABLE IN CONDUIT, 600V (XLP-TYPE USE) 1/C NO.8

81702155 120ELECTRIC CABLE IN CONDUIT, 600V (XLP-TYPE USE) 1/C NO.1

84200500 3REMOVAL OF LIGHTING UNIT, SALVAGE

84200600 7REMOVAL OF LIGHTING UNIT, NO SALVAGE

84200804 10REMOVAL OF POLE FOUNDATION

84500110 1REMOVAL OF LIGHTING CONTROLLER

84500120 1REMOVAL OF ELECTRIC SERVICE INSTALLATION

X8040102 1ELECTRIC SERVICE INSTALLATION, SPECIAL

X8130110 12JUNCTION BOX, SPECIAL

X8250505 1LIGHTING CONTROLLER, SPECIAL

X8360120 10LIGHT POLE FOUNDATION, SPECIAL METAL HELIX TYPE

XX008068 10LUMINAIRE INSTALLATION, TYPE 1

BILL OF MATERIALS

FOOT

FOOT

FOOT

EACH

EACH

EACH

EACH

EACH

EACH

EACH

EACH

EACH

EACH

83000400 10LIGHT POLE, ALUMINUM, 30 FT, M.H., 10 FT. DAVIT ARM EACH

100'0' 50'

ROADWAY LIGHTING OVERVIEW PLAN

SPRINGFIELD AVE.

N . C

O

LE

R A

VE

S. CO

LER AVE.

M cCULLO

UG

H ST.

W. STOUGHTON ST.

028C943

CONTROLLER #028

LIGHTING

028A933

028A931 028A929

028A927 028A926

028A925

028C928

028C932

028D934

SPRINGFIELD AVE.

SPRINGFIELD AVE.

M

AT

CH

LI

NE

ST

A.

8+

.0

37+52.8

19.0' LT

028A933

37+49.8

19.0' LT

028JB1

36+06.9

19.0' LT

028C943

36+03.9

19.0' LT

028JB7

100+80.0

22.5' RT

028JB8

100+83.0

22.5' RT

028D934

100+80.0

22.5' RT

028JB10

38+32.6

21.0' RT

028C932

36+20.5

22.5' RT

028JB9

028C

028C

028C

028A

028B

KEYNOTES

1. EXISTING LIGHTING UNIT (POLE, FOUNDATION, AND LUMINAIRE) TO BE

REMOVED COMPLETE.

2. EXISTING UNDERGROUND LIGHTING CONDUCTORS TO BE CUT-OFF BELOW

GRADE AND ABANDONED IN PLACE. ANY ABANDONED CONDUCTORS THAT

INTERFERE WITH THE PROPOSED IMPROVEMENTS SHALL BE REMOVED AT

THE POINT OF CONFLICT, AND NO ADDITIONAL COMPENSATION WILL BE

ALLOWED.

3. EXISTING LIGHTING UNIT (POLE AND LUMINAIRE) AND EXISTING LIGHTING

CONDUCTORS TO REMAIN AND BE REFED FROM NEW CIRCUIT. SEE

KEYNOTE 4.

4. INTERCEPT EXISTING LIGHTING CONDUCTORS TO EXISTING LIGHTING POLE

IN NEW JUNCTION BOX.

5. EXISTING LIGHTING CONTROLLER AND METER TO BE REMOVED AND

REPLACED WITH NEW LIGHTING CONTROLLER AND METER. EXISTING

AMEREN ILLINOIS SERVICE TO REMAIN AND BE REUSED. INTERCEPT AND

EXTEND SERVICE CONDUCTORS AS NEEDED.

6. EXISTING AMEREN ILLINOIS SERVICE RISER POLE TO REMAIN.

7. BORE 2" CONDUIT UNDER ROAD.

8. PROVIDE SPARE 2" CONDUIT FROM CONTROLLER TO JUNCTION BOX 028JB1.

9. PROVIDE SPARE 2" CONDUIT FROM CONTROLLER TO JUNCTION BOX 028JB7.

CIRCUIT DESIGNATION SCHEME

40+06.0

20.5' LT

028A929

POLE NUMBERLIGHTING CONTROLLER

CIRCUIT

POLE LOCATION

NOTE:

THE CONTRACTOR SHALL PROVIDE A PERMANENT

STICKER INSIDE HAND HOLE OF EACH LIGHT POLE

INDICATING THE LIGHTING CONTROLLER, CIRCUIT

AND POLE NUMBER.

028A

LIGHTING CONTROLLER AND CIRCUIT

NUMBER OF CONDUCTORS OF THIS SIZE

IN CONDUIT.

* INDICATES INCLUDES GROUND

CONDUCTOR SIZE FOR COPPER

CONDUCTORS IN AWG

CONDUCTOR SYMBOL SCHEME

41+20.2

21.0' RT

028JB22

JUNCTION BOX LOCATION

JUNCTION BOX NUMBERLIGHTING CONTROLLER

JUNCTION BOX DESIGNATION SCHEME

37+25.4

21.5' LT

CONTROLLER #028

LIGHTING

3028D935

028C9443

028C9453

028D

7 3

028D

* 2

028C 028D

NOTES

1. EXISTING OVERHEAD ELECTRICAL/UTILITY POLES AND LINES TO REMAIN.

2. LIGHT POLE LOCATIONS MAY BE ADJUSTED IN THE FIELD AS DIRECTED BY

THE ENGINEER TO AVOID UTILITY CONFLICTS, AND NO ADDITIONAL

COMPENSATION WILL BE ALLOWED.

SPRINGFIELD AVE.

N . C

O

LE

R A

VE

S. CO

LER AVE.

SPRINGFIELD AVE.

40'0' 20'

L1

L1 L1

L1

KEYNOTES

1. EXISTING LIGHTING UNIT (POLE, FOUNDATION, AND LUMINAIRE) TO BE

REMOVED COMPLETE.

2. EXISTING UNDERGROUND LIGHTING CONDUCTORS TO BE CUT-OFF BELOW

GRADE AND ABANDONED IN PLACE. ANY ABANDONED CONDUCTORS THAT

INTERFERES WITH THE PROPOSED IMPROVEMENTS SHALL BE REMOVED AT

THE POINT OF CONFLICT, AND NO ADDITIONAL COMPENSATION WILL BE

ALLOWED.

3. EXISTING LIGHTING UNIT (POLE AND LUMINAIRE) AND EXISTING LIGHTING

CONDUCTORS TO REMAIN AND BE REFED FROM NEW CIRCUIT. SEE

KEYNOTE 4.

4. INTERCEPT EXISTING LIGHTING CONDUCTORS TO EXISTING LIGHTING POLE

IN NEW JUNCTION BOX.

M

AT

CH

LI

NE

ST

A.

8+

.0

41+23.2

21.0' RT

028C928

41+20.2

21.0' RT

028JB1239+86.5

21.0' RT

028JB11 3

028C

028C

3028C930

40+09.0

20.5' LT

028JB3

40+06.0

20.5' LT

028A929

3 028B947

028B9483

3028B946

39+12.8

21.0' LT

028A93139+09.8

21.0' LT

028JB2

028A

42+21.0

26.5' LT

028A927

42+21.0

26.5' LT

028JB4

43+06.5

27.5' LT

028A926

43+03.5

27.5' LT

028JB5

43+69.7

29.0' LT

028A925

43+66.7

29.0' LT

028JB6

028A

028A

028A9513

028A

028A

CIRCUIT DESIGNATION SCHEME

40+06.0

20.5' LT

028A929

POLE NUMBERLIGHTING CONTROLLER

CIRCUIT

POLE LOCATION

NOTE:

THE CONTRACTOR SHALL PROVIDE A PERMANENT

STICKER INSIDE HAND HOLE OF EACH LIGHT POLE

INDICATING THE LIGHTING CONTROLLER, CIRCUIT

AND POLE NUMBER.

028A

LIGHTING CONTROLLER AND CIRCUIT

NUMBER OF CONDUCTORS OF THIS SIZE

IN CONDUIT.

* INDICATES INCLUDES GROUND

CONDUCTOR SIZE FOR COPPER

CONDUCTORS IN AWG

CONDUCTOR SYMBOL SCHEME

41+20.2

21.0' RT

028JB22

JUNCTION BOX LOCATION

JUNCTION BOX NUMBERLIGHTING CONTROLLER

JUNCTION BOX DESIGNATION SCHEME

028B

028B

NOTES

1. EXISTING OVERHEAD ELECTRICAL/UTILITY POLES AND LINES TO REMAIN.

2. LIGHT POLE LOCATIONS MAY BE ADJUSTED IN THE FIELD AS DIRECTED BY

THE ENGINEER TO AVOID UTILITY CONFLICTS, AND NO ADDITIONAL

COMPENSATION WILL BE ALLOWED.

SPRINGFIELD AVE.

M cCULLO

UG

H ST.

4 4

4 2

40'0' 20'

L1

L1

L1

L1

L1

L1

(SALVAGE)

(SALVAGE)

(SALVAGE)

LIGHTING CONTROLLER #028

NO SCALE

DIAGRAMMATIC ASSEMBLY DETAIL

CONTROL CABINET, FOUNDATION AND

FRONT VIEW

(LOOKING SOUTH)

SIDE VIEW

(LOOKING WEST)

100A, 120/240V, 1Ø, 30 CIRCUIT PANELBOARD (INTERIOR ONLY,

NO PANEL TUB), QUANTITIES OF BREAKERS AS SHOWN IN

PANELBOARD SCHEDULES.

HAND-OFF-PHOTOCELL - TIMER SELECTOR SWITCH WITH LEGEND PLATE.

120 VAC, 20A, 1P PLUNGER TYPE SWITCH FOR CONTROLLER LIGHT,

DOOR ACTIVATED.

LIGHTING CONTROLLER #028 BILL OF MATERIALS

INCANDESCENT LIGHT FIXTURE WITH CLEAR GLOBE AND

PROTECTIVE GUARD. PROVIDE 60WATT, 130VAC LAMP.

ASTRONOMICAL TIME CLOCK WITH BATTERY MEMORY BACKUP

(CAPACITANCE BACKUP IS ACCEPTABLE IF AVAILABLE).

ONE CIRCUIT TO CONTROL LIGHTING CONTACTORS.

DUPLEX RECEPTACLES, 120VAC, 20A, GFCI TYPE.

TERMINAL STRIPS. QUANTITY AS REQUIRED FOR INCOMING WIRING

PLUS 100% SPARE TERMINALS. PROVIDE SEPARATE TERMINAL

STRIPS FOR POWER, NEUTRAL AND GROUND WIRING AS REQUIRED.

LIGHTING CONTACTOR (LC-A, LC-B, LC-C, LC-D), 30A, 240VAC,

4 POLE, 120 VAC ELECTRICALLY HELD COIL. PROVIDE SPACE

FOR ADDITIONAL CONTACTORS.

SURGE ARRESTOR.

CONTROL WIRING TERMINAL BLOCK.

(1) 2" RGS CONDUIT

WITH 3#1

INSTALLATION

MOUNTING BOARD

CONTROLLER

CABINET

CONTRACTOR SHALL PROVIDE UTILITY

METER BASE. COORDINATED EXACT

REQUIREMENTS WITH AMEREN ILLINOIS

EXOTHERMIC WELD

CONTRACTOR SHALL PROVIDE UTILITY

METER BASE. COORDINATE EXACT

REQUIREMENTS WITH AMEREN ILLINOIS

2P, 100A, NEMA 4X SS FUSED DISCONNECT

SWITCH WITH 100A FUSES. SWITCH SHALL

BE LOCKABLE IN OPEN AND CLOSED POSITION

CONTROLLER

CABINET

(1) 2" RGS CONDUIT

WITH 3#1

(1) 2" RGS CONDUIT

WITH 3#1, 1#4G

CONCRETE

FOUNDATION

(TYPE D. SEE

STD. 878001)

FINISHED GRADE LINE

(1) 1" PVC CONDUIT

WITH 1#4 GROUND

3 4

1"

CONCRETE

FOUNDATION

(TYPE D. SEE

STD. 878001)

6"6"

PROVIDE (2) 2" PVC CONDUITS INTO CABINET FOR ROADWAY

LIGHTING CIRCUITS:

CONDUIT 1 - 4#8, 1#8G (LTG. CKTS. A & B)

CONDUIT 2 - EMPTY SPARE FOR FUTURE USE

CONDUITS SHALL BE ROUTED TO HANDHOLE AS

SHOWN ON THE PLANS

3/4" DIA. X 10' COPPER

CLAD GROUND ROD

#4 BARE GROUND WIRE

(1) 1" PVC CONDUIT

FOR GROUND WIRE

(1) 2" SCHEDULE 80 CONDUIT

WITH 3#1 TO UTILITY POLE

FINISHED GRADE LINE

PHOTOCELL SWITCH WITH LOCKING TYPE RECEPTACLE

AND INTEGRAL SURGE ARRESTORS. PHOTOCELL SHALL BE

CABINET MOUNTED AND SHIELDED FROM SURROUNDING

LIGHT SOURCES, WITH TIME DELAY RELAY TO PREVENT

NUISANCE SWITCHING. (SEE PHOTOCELL DETAIL)

1 11

CLEAR GLASS LENS,

COVER, & NEOPRENE

GASKET BETWEEN

COVER & CABINET

PHOTOCELL

(LOCATED INSIDE

CONTROL CABINET)

14" STAINLESS STEEL

BOLTS WITH

SELF-LOCKING NUTS

18" x 6" x 8"

ALUMINUM SHEET

6"

3" HOLE IN SIDE

OF CAST CABINET

14" STAINLESS STEEL BOLT

WITH ALUMINUM SLEEVE

AS STANDOFF. USE

SELF-LOCKING NUTS.

2"

PHOTOCELL DETAIL

NO SCALE

PROVIDE (2) 2" PVC CONDUITS INTO CABINET FOR ROADWAY

LIGHTING CIRCUITS:

CONDUIT 1 - 4#8, 1#8G (LTG. CKTS. C & D)

CONDUIT 2 - EMPTY SPARE FOR FUTURE USE

CONDUITS SHALL BE ROUTED TO HANDHOLE AS

SHOWN ON THE PLANS

NH

120V

120V H20A/1P

PHOTOCELL

TIMECLOCK

HAND TIMECLOCK

OFF PHOTOCELL

"ROADWAY

LIGHTING"

LC-A

LC-B

LC-C

LC-D

GFI

00X0

000X

X000

CONTROLLER

LIGHT AND SWITCH

NOTE:

GROUND WIRE NOT SHOWN FOR CLARITY. CONTRACTOR SHALL GROUND

ALL EQUIPMENT IN THE LIGHTING CONTROL CABINET AS REQUIRED BY

THE 2020 NATIONAL ELECTRICAL CODE.

LIGHTING CONTROLLER #028 CONTROL DIAGRAM

NO SCALE

TO AMEREN IP

TRANSFORMER

100 AMP

MAIN BREAKER

30 AMP

2 POLE

30 AMP

2 POLE

30 AMP

2 POLE

30 AMP

2 POLE

30 AMP

2 POLE

20 AMP

1 POLE

20 AMP

1 POLE

TO LIGHTING

CIRCUIT A

TO LIGHTING

CIRCUIT B

TO LIGHTING

CIRCUIT C

TO LIGHTING

CIRCUIT D

CONTROL

CIRCUIT

CONTROLLER

LIGHT AND GFI

LIGHTING

CONTACTOR

LC-A

LIGHTING

CONTACTOR

LC-B

LIGHTING

CONTACTOR

LC-C

LIGHTING

CONTACTOR

LC-D

SURGE

ARRESTOR

LIGHTING CONTROLLER #028

LIGHTING CONTROLLER #028 ELECTRICAL ONE-LINE DIAGRAM

LIGHTING CONTROLLER #028 PANELBOARD SCHEDULE

INSTALLATION DETAIL

LIGHT POLE FOUNDATION

A

D

POLE HANDHOLE

POLE/ARM DIAGRAMMATIC ONLY

B

C

MOUNTING PLATE

AT FINAL GRADE

KEYNOTES

A METAL FOUNDATION IN ACCORDANCE WITH STANDARD 836001 AND THE SPECIAL PROVISIONS.

B LED LUMINAIRE AS SHOWN ON THE PLANS.

C CONDUIT AND CABLE TO GULBOX JUNCTOIN OR JUNCTION BOX SPECIAL AS SHOWN ON THE PLANS.

D ALUMINUM LIGHT POLE AS SHOWN ON THE PLANS.

WITH EQUIPMENT GROUNDING CONDUCTOR

NO SCALE

2 WIRE - 240 VAC (UNDERGROUND CONDUCTORS)

DETAIL "A"

DOUBLE POLE

POLE FOUNDATION DETAIL

NO SCALE

VENTILATING SCREEN,

STAINLESS STEEL

FOUNDATION AS

SHOWN IN PLANS

LIGHT POLE

TYPICAL GROUNDING CONNECTIONS

NO SCALE

HEX HEAD BOLT

12" x 1 12" - 13 TPI

#4 AWG EQUIPMENT

GROUNDING CONDUCTOR

FROM THE GROUNDING

ELECTRODE

COMPRESSION CONNECTOR EQUAL

TO BURNDY TYPE YA4C-N-45

NUT

LOCK WASHER

FLAT WASHER

FACTORY STUD WELDED

TO POLE

NOTE: NUT, BOLT, AND WASHERS SHALL BE STAINLESS STEEL.

GROUNDING ROD INSTALLATION DETAIL

NO SCALE

EQUIPMENT GROUNDING

CONDUCTOR FROM THE

GROUNDING ELECTRODE

THRU THE COMPRESSION

CONNECTOR.

LOCKNUT WASHER

NUT

FACTORY WELDED

BRACKET TO POLE

COMPRESSION CONNECTOR EQUAL

TO BURNDY TYPE YA4C-N-

HEX HEAD BOLT

12" x 1 12" - 13 TPI

FLAT WASHER

NEMA APPROVED

GROUND CONNECTOR

12" - 13 UNC STUD,

SILICON BRONZE

12" NUT OR THREADED

FACTORY WELDED BRACKET

TO POLE SHAFT

JUNCTION BOX INSTALLATION DETAIL

NO SCALE

1-1/C #6, 600V, XLP-TYPE

USE (GROUND)

2-1/C #6 ELECTRIC CABLES AND

1-1/C #6 ELECTRICAL CABLE GRND.,

600V, XLP-USE

COMPRESSION CONNECTOR

2" DIA. COILABLE

NONMETALIC CONDUIT

6" TOPSOIL ABOVE COMPACTED

CLAY SUBSOIL OR CONCRETE

SURFACE

COMPACTED CA-6 DOWN

TO UNDISTURBED EARTH,

MINIMUM 6" DEPTH

2" DIA. PVC CONDUIT

IN TRENCH

COMPACTED CLAY SUBSOIL

AROUND INCOMING CONDUITS

#10 AWG EQUIPMENT

GROUNDING CONDUCTOR

TO ROADWAY LUMINAIRE

TYPICAL GROUNDING

CONNECTION - SEE DETAIL

APPROVED COMPRESSION TYPE

CONNECTOR FOR EQUIPMENT

GROUNDING CONDUCTORS

AWG #4 (MIN.) BARE EQUIPMENT

GROUNDING CONDUCTOR. NOTE:

THIS WIRE SHALL BE CONTINUOUS

WITHOUT SPLICES FROM THE

GROUNDING ELECTRODE TO THE

EQUIPMENT GROUNDING

CONDUCTOR SPLICE CONNECTOR

U.S.E.RATED XLP INSULATED

COPPER STRANDED EQUIPMENT

GROUNDING CONDUCTORS FROM

SYSTEM RACEWAY

EXOTHERMICALLY WELDED TO

GROUNDING ELECTRODE

UNGROUNDED CONDUCTORS TO

ROADWAY LUMINAIRE SHALL BE #10

AWG, COPPER STRANDED, U.S.E.

RATED, XLP INSULATED. CONNECT

TO ROADWAY LUMINIARE WITH

CRIMP TYPE CONNECTORS EQUAL

TO 3M TYPE MV.

CIRCUIT TAGS, BOTH SIDES

OF ALL FUSES (TYPICAL)

IN LINE FUSE ASSEMBLY

TWO POLE, 600 VAC, WITH

5 AMP FNQ FUSES (SEE

DETAIL "A") TAPE AND

VARNISH CRIMPED END

FERRULES FUSE HOLDER

EQUAL TO BUSSMAN TYPE

HEX-A-A WITH INSULATING

BOOTS. (TYPICAL)

LARGE HANDHOLE & COVER

U.S.E.RATED XLP INSULATED

COPPER STRANDED UNGROUNDED

CIRCUIT CONDUCTORS FROM

SYSTEM RACEWAY

COMPOSITE CONCRETE JUNCTION

BOX APPROX. 12"X12"X12"

GROUND ROD

EXCAVATE TO UNDISTURBED

SUBSOIL AND BACKFILL

UNDER BOX WITH CA-6

LI

G

H T

PO

LE

F O

U N

D

AT

IO

N

COMPOSITE CONCRETE

JUNCTION BOX

HYDRAULIC CRIMP

CONNECTION

SPLICE CABLES

2-1/C #6, 600V, XLP-USE

SPLIT BOLT

CONNECTOR

58 X 10' COPPER CLAD STEEL

GROUND ROD INCIDENTAL TO

JUNCTION BOX

G

RE

EN

BL

AC

K

BL

AC

K

G

RE

EN

RE

D

RE

D

BA

R

E

2" DIA. PVC CONDUIT

IN TRENCH

MOUNT POLE TO

FOUNDATOIN USING A

BREAKAWAY COUPLING

SYSTEM

E MOUNT POLE TO METAL FOUNDATION USING A BASE BREAKAWAY COUPLING SYSTEM.

E

Sheets and Views
1 COVER SHEET
2 SUMMARY OF QUANTITIES
3 SCHEDULE OF QUANTITIES
4 SCHEDULE OF QUANTITIES
5 EXISTING TYPICAL SECTIONS
6 PROPOSED TYPICAL SECTIONS
7 DETOUR ROUTE
8 REMOVALS PLAN
9 PLAN AND PROFILE
10 PLAN AND PROFILE
11 P.C.C. PAVEMENT GRADING AND DRAINAGE
12 SLAB OVER CULVERT - STRUCTURE 6110
13 JOINTING PLAN
14 PAVEMENT MARKINGS
15 ADA CURB RAMP DETAILS
16 BOX CULVERT SECTION - STRUCTURE 6110
17 MISCELLANEOUS DETAILS
18 MISCELLANEOUS DETAILS
19 EXISTING BOX CULVERT PLANS

File details come from the government source that posted it. Updated .