This is a Hazardous/Regulated Materials Survey & Inspection Report and Pre-Demolition Engineering Survey prepared for the City of Detroit Demolition Department regarding the residential property at 21610 Lyndon Street, Detroit, Michigan (Parcel #22010232-3). The inspection was conducted on August 7, 2026, and the report was issued on August 14, 2026, by Environmental Testing & Consulting, Inc. The survey identified asbestos-containing materials and hazardous substances within a single-story house with attached garage built in 1965, totaling 851 square feet on a concrete slab foundation. Key findings include asbestos-containing materials such as basement window glaze (2-4 units), transite siding (1,280 square feet), and various floor tiles and mastics distributed throughout the structure. Hazardous materials identified include seven paint cans, one smoke detector, one washer, one dryer, and one stove located throughout the functional spaces. The engineering survey documented ten exterior areas and twelve functional spaces, with one functional space noted as completely inaccessible due to unknown animals living inside. Laboratory analysis using Polarized Light Microscopy confirmed the presence of chrysotile asbestos in specific materials, including 2% asbestos in basement window glaze and 10% asbestos in transite siding samples, with trace amounts detected in drywall composite materials.
The report includes comprehensive material quantification detailing 30 distinct materials requiring remediation during the demolition process, with quantities ranging from zero to 5,860 square feet depending on material type and location. All bulk samples were collected on August 7, 2026, and analyzed with a 72-hour turnaround time, with results completed and revised by August 12-13, 2026. The analysis employed EPA-approved testing methods (EPA 600/R-93-116 and EPA 600/M4-82/020) with polarized light microscopy and point count methodology where required. Several samples triggered positive stop protocols, indicating confirmed asbestos presence that halted further analysis of duplicate samples. The contractor is responsible for verifying all asbestos quantities identified during the bidding process, as reported quantities are estimates only. This survey documentation serves as the baseline environmental assessment required for the planned residential demolition project (Group 9.3.26) and establishes the scope of hazardous materials abatement and disposal requirements that must be incorporated into demolition bid specifications.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Hazardous/Regulated Materials Survey & Inspection Report
21610 Lyndon Street, Detroit, MI 48223 Parcel #: 22010232-3
Date of Inspection: 08/07/2026 Date of Report: 08/14/2026
Prepared For:
City of Detroit Demolition Department
1301 3rd Avenue, 6th Floor
Detroit, MI 48226
Project #: 2026 BPO 7.20.2026
Fieldwork conducted by: Report Reviewed and Approved by:
Andre Richardson Mark Smith Michigan Asbestos Inspector License #: A45125 Michigan Asbestos Inspector License #: A55707 Inspector’s E-Mail: Andre.Richardson@2etc.com E-Mail: Mark.Smith@2etc.com
38900 West Huron River Drive Romulus, MI 48174
734-955-6600 www.2etc.com
Hazardous/Regulated Materials Survey & Inspection Report ETC Job #: 293027
21610 Lyndon Street, Detroit, MI 48223 Parcel #: 22010232-3
Asbestos Containing Materials
TABLE 1: ASBESTOS CONTAINING MATERIALS
Category Material Description Location Quantity
M Basement Window Glaze, Cream EA 2-4 7 Units
M Transite Siding, White EA 1-4 1280 SF TSI = Thermal System Insulation; S = Surfacing; M = Miscellaneous; SF= Square Feet; LF = Linear Feet;
CY = Cubic Yards; CF = Cubic Feet
Quantities that are listed are estimates only. It is the contractor’s responsibility to verify all amounts of asbestos identified during the bid process.
Hazardous Materials & Tires
TABLE 2: HAZARDOUS MATERIALS
Material Description Location Quantity
Paint Cans FS 6 7
Smoke Detector FS 6 1
Washer FS 1 1
Dryer FS 1 1
Stove FS 1 1
Engineering Survey
21610 Lyndon Street
Reviewed 08/2025
Pre-Demolition Engineering Survey Report
Detroit, MI 48223
Prepared for City of Detroit Demolition Department
1301 Third Street, 6th Floor Detroit, Michigan 48226
Prepared by Environmental Testing & Consulting, Inc.
38900 West Huron River Drive Romulus, MI 48174
Report Date August 5, 2026
Reviewed 08/2025
Survey Details and Site Information Date(s) of Engineering Survey: July 29, 2026
Engineering Survey Inspector name: Jeremy Westcott
Engineering Survey Inspector #: INSP01045
Engineering Survey Inspector email: Jeremy.Westcott@2etc.com
Engineering Survey Inspector phone #: 734-955-6600
Engineering Survey Inspector signature:
Reviewing PE/Architect name:
Reviewing PE/Architect license state/#:
Reviewing PE/Architect email:
Reviewing PE/Architect phone #:
Reviewing PE/Architect signature:
Property Address: 21610 Lyndon Street, Detroit, MI 48223
# and types of structure(s): 1 House + 1 Garage
Foundation type Concrete Slab
Year built: 1965
# of floors: 1
Total square footage: 851 ft2
William Earle, P.E. (WI)
WI 35407-6
William.Earle@oneatlas.com
847-971-0979
Engineering Survey Findings – Exterior Areas
Designation Inaccessible Reason Description/Notes
EA-1
EA-2
EA-3
EA-4
EA-5
EA-6
EA-7
EA-8
EA-9
EA-10
Key:
• Inaccessible: “P” = Partially inaccessible; “C” = Completely inaccessible
• Reason: “F” = Fire damage, “W” = Water damage, “S” = Structural damage, “T” = Termite damage, “O” = Other damage
Reviewed 08/2025
Engineering Survey Findings – Functional Spaces
Designation Inaccessible Reason Description/Notes
FS-1
FS-2
FS-3
FS-4
FS-5
FS-6
FS-7
FS-8
FS-9
FS-10
FS-11
FS-12 C O Unknown animals living inside
Key:
• Inaccessible: “P” = Partially inaccessible; “C” = Completely inaccessible
• Reason: “F” = Fire damage, “W” = Water damage, “S” = Structural damage, “T” = Termite damage, “O” = Other damage
Site Drawings
Site Photographs
EA1 EA2
EA3
EA4
EA5 EA6
EA7
EA8
EA9 EA10
FS1
FS2
FS3 FS4
FS5
FS6
FS7 FS8
FS9
FS10
FS11
Electronic Chain of Custody
Submitting Client:
Detroit, MI - 48226
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Environmental Testing Laboratories, Inc.
City of Detroit - Demolition Department
1301 Third Street - Suite 606
Asbestos-Bulk
72 Hours
Yes
Yes, 400.00 Points
ETC DEMO
Sample Type:
Turn Around:
Positive Stop:
Point Counting:
P.C. Criteria:
Sample ID Client Sample ID
ETL Project :Project Location: 29302721610 Lyndon St, Detroit, MI 48223
Collection DateSample Location Sample Description
1917247 2026-08-071A FS1 Concrete / Floor - Grey - HA(1)
1917248 2026-08-071B FS2 Concrete / Floor - Grey - HA(1)
1917249 2026-08-071C FS1 Concrete / Floor - Grey - HA(1)
1917250 2026-08-072A EA2 basement window glaze - Cream - HA(2)
1917251 2026-08-072B EA3 basement window glaze - Cream - HA(2)
1917252 2026-08-072C EA4 basement window glaze - Cream - HA(2)
1917253 2026-08-073A FS3 Floor / Tile - Green - HA(3)
1917254 2026-08-073B FS4 Floor / Tile - Green - HA(3)
1917255 2026-08-073C FS3 Floor / Tile - Green - HA(3)
1917256 2026-08-074A FS3 Floor / Tile Mastic - Clear - HA(4)
1917257 2026-08-074B FS4 Floor / Tile Mastic - Clear - HA(4)
1917258 2026-08-074C FS3 Floor / Tile Mastic - Clear - HA(4)
1917259 2026-08-075A FS3 Floor / Tile - Brown - HA(5)
1917260 2026-08-075B FS4 Floor / Tile - Brown - HA(5)
1917261 2026-08-075C FS3 Floor / Tile - Brown - HA(5)
1917262 2026-08-076A FS3 Floor / Tile Mastic - Brown - HA(6)
1917263 2026-08-076B FS4 Floor / Tile Mastic - Brown - HA(6)
1917264 2026-08-076C FS3 Floor / Tile Mastic - Brown - HA(6)
1917265 2026-08-077A FS3 Floor / Tile - Cream - HA(7)
1917266 2026-08-077B FS4 Floor / Tile - Cream - HA(7)
Sample ID Client Sample ID
ETL Project :Project Location: 29302721610 Lyndon St, Detroit, MI 48223
Collection DateSample Location Sample Description
1917267 2026-08-077C FS3 Floor / Tile - Cream - HA(7)
1917268 2026-08-078A FS3 Floor / Tile Mastic - Clear - HA(8)
1917269 2026-08-078B FS4 Floor / Tile Mastic - Clear - HA(8)
1917270 2026-08-078C FS3 Floor / Tile Mastic - Clear - HA(8)
1917271 2026-08-079A FS4 Adhesive / - - Brown - HA(9)
1917272 2026-08-079B FS4 Adhesive / - - Brown - HA(9)
1917273 2026-08-079C FS4 Adhesive / - - Brown - HA(9)
1917274 2026-08-0710A FS4 Caulk / Interior - White - HA(10)
1917275 2026-08-0710B FS7 Caulk / Interior - White - HA(10)
1917276 2026-08-0710C FS4 Caulk / Interior - White - HA(10)
1917277 2026-08-0711A FS3 Ceiling / Wall / Drywall Composite - White -
HA(11)
1917278 2026-08-0711B FS4 Ceiling / Wall / Drywall Composite - White -
HA(11)
1917279 2026-08-0711C FS5 Ceiling / Wall / Drywall Composite - White -
HA(11)
1917280 2026-08-0712A FS7 Adhesive / - - Brown - HA(12)
1917281 2026-08-0712B FS7 Adhesive / - - Brown - HA(12)
1917282 2026-08-0712C FS7 Adhesive / - - Brown - HA(12)
1917283 2026-08-0713A FS11 Insulation / Blown-in - Yellow - HA(13)
1917284 2026-08-0713B FS11 Insulation / Blown-in - Yellow - HA(13)
1917285 2026-08-0713C FS11 Insulation / Blown-in - Yellow - HA(13)
1917286 2026-08-0714A EA1 Concrete / Porch - Grey - HA(14)
1917287 2026-08-0714B EA1 Concrete / Porch - Grey - HA(14)
1917288 2026-08-0714C EA1 Concrete / Porch - Grey - HA(14)
1917289 2026-08-0715A EA1 Concrete / Walkway - Grey - HA(15)
1917290 2026-08-0715B EA2 Concrete / Walkway - Grey - HA(15)
1917291 2026-08-0715C EA3 Concrete / Walkway - Grey - HA(15)
1917292 2026-08-0716A EA1 Wall (Ext.) / Brick - Red - HA(16)
1917293 2026-08-0716B EA6 Wall (Ext.) / Brick - Red - HA(16)
Collection DateSample Location Sample Description
1917294 2026-08-0716C EA7 Wall (Ext.) / Brick - Red - HA(16)
1917295 2026-08-0717A EA1 Mortar / Brick - Grey - HA(17)
1917296 2026-08-0717B EA6 Mortar / Brick - Grey - HA(17)
1917297 2026-08-0717C EA7 Mortar / Brick - Grey - HA(17)
1917298 2026-08-0718A EA2 Transite / Siding - White - HA(18)
1917299 2026-08-0718B EA3 Transite / Siding - White - HA(18)
1917300 2026-08-0718C EA4 Transite / Siding - White - HA(18)
1917301 2026-08-0719A EA2 Transite Seam Tape - Black - HA(19)
1917302 2026-08-0719B EA3 Transite Seam Tape - Black - HA(19)
1917303 2026-08-0719C EA4 Transite Seam Tape - Black - HA(19)
1917304 2026-08-0720A EA2 Wall (Ext.) / Vapor Barrier - Black - HA(20)
1917305 2026-08-0720B EA3 Wall (Ext.) / Vapor Barrier - Black - HA(20)
1917306 2026-08-0720C EA4 Wall (Ext.) / Vapor Barrier - Black - HA(20)
1917307 2026-08-0721A EA2 Concrete / Driveway - Black - HA(21)
1917308 2026-08-0721B EA2 Concrete / Driveway - Black - HA(21)
1917309 2026-08-0721C EA2 Concrete / Driveway - Black - HA(21)
1917310 2026-08-0722A EA1 Caulk / Exterior - White - HA(22)
1917311 2026-08-0722B EA2 Caulk / Exterior - White - HA(22)
1917312 2026-08-0722C EA3 Caulk / Exterior - White - HA(22)
1917313 2026-08-0723A EA1 Concrete / Wall - Grey - HA(23)
1917314 2026-08-0723B EA2 Concrete / Wall - Grey - HA(23)
1917315 2026-08-0723C EA3 Concrete / Wall - Grey - HA(23)
1917316 2026-08-0724A EA5 Roofing / Asphalt (Shingles) - Black - HA(24)
1917317 2026-08-0724B EA5 Roofing / Asphalt (Shingles) - Black - HA(24)
1917318 2026-08-0724C EA5 Roofing / Asphalt (Shingles) - Black - HA(24)
1917319 2026-08-0725A EA5 Roofing / Asphalt (Shingles) - Black - HA(25)
1917320 2026-08-0725B EA5 Roofing / Asphalt (Shingles) - Black - HA(25)
1917321 2026-08-0725C EA5 Roofing / Asphalt (Shingles) - Black - HA(25)
Collection DateSample Location Sample Description
1917322 2026-08-0726A EA5 Roofing / Tar Paper - Black - HA(26)
1917323 2026-08-0726B EA5 Roofing / Tar Paper - Black - HA(26)
1917324 2026-08-0726C EA5 Roofing / Tar Paper - Black - HA(26)
1917325 2026-08-0727A EA10 Roofing / Asphalt (Shingles) - Black - HA(27)
1917326 2026-08-0727B EA10 Roofing / Asphalt (Shingles) - Black - HA(27)
1917327 2026-08-0727C EA10 Roofing / Asphalt (Shingles) - Black - HA(27)
1917328 2026-08-0728A EA10 Roofing / Asphalt (Shingles) - Black - HA(28)
1917329 2026-08-0728B EA10 Roofing / Asphalt (Shingles) - Black - HA(28)
1917330 2026-08-0729A EA10 Roofing / Tar Paper - Black - HA(29)
1917331 2026-08-0729B EA10 Roofing / Tar Paper - Black - HA(29)
1917332 2026-08-0729C EA10 Roofing / Tar Paper - Black - HA(29)
1917333 2026-08-0730A FS12 Concrete / Garage - Grey - HA(30)
1917334 2026-08-0730B FS12 Concrete / Garage - Grey - HA(30)
1917335 2026-08-0730C FS12 Concrete / Garage - Grey - HA(30)
Seal Intact:
Preservative (if required):
Containers Labled :
Yes
Yes
Analyst
Yes
Collection DateSample Location Sample Description
Received By:
Received Date:
Relinquished By:
Relinquished Date:
James Farinas
2026-08-07 12:00 AM
Andre Richardson
Aug 7 2026 12:00AM Ben Jones
Erica Marcos
OJ Ivey
Teagan Murphy
Material List
Client : City of Detroit - Demolition Department 1301 Third Street - Suite 606 Detroit, MI - 48226
Project Location: 21610 Lyndon St. Detroit Mi. Job #:293027
Material Id Material Description Material Sub Classification Size Quantity Locations
1 Concrete/F loor-Grey F loor M 980 S F F S-01,F S-02
2 basement window glaze-C ream M 7 Unit E A-02,E A-03,E A-04
3 F loor/Ti le-Green Tile M 199 S F F S-03,F S-04
4 F loor/Ti le Mastic-C lear Ti le Mastic M 199 S F F S-03,F S-04
5 F loor/Ti le-B rown Tile M 199 S F F S-03,F S-04
6 F loor/Ti le Mastic-B rown Tile Mastic M 199 S F F S-03,F S-04
7 F loor/Ti le-C ream Tile M 199 S F F S-03,F S-04
8 F loor/Ti le Mastic-C lear Ti le Mastic M 199 S F F S-03,F S-04
9 Adhesive/--B rown - M 35 S F F S-04
10 Caulk/Interior-White Interior M 32 LF F S-04,F S-07
11 Ceiling / Wall/D rywall Composite- White
Drywall Composite M 5860
S F F S-01,F S-02,F S-03,F S-04,F S-05,F S-06,F S-07,F S-08,F S-
09,F S-10
12 Adhesive/--B rown - M 99 S F F S-07
13 Insulation/B lown-in-Yellow B lown-in T 890 S F F S-11
14 Concrete/Porch-Grey Porch M 0 S F E A-01
15 Concrete/Walkway-Grey Walkway M 185 S F E A-01,E A-02,E A-03,E A-04
16 Wall (Ext.)/B rick-Red Brick M 1280 S F E A-01,E A-06,E A-07,E A-08,E A-09
17 Mortar/B rick-Grey Brick M 1280 S F E A-01,E A-06,E A-07,E A-08,E A-09
18 Transite/S iding-White S iding M 1280 S F E A-01,E A-02,E A-03,E A-04
19 Transite Seam Tape-B lack M 1280 S F E A-01,E A-02,E A-03,E A-04
20 Wall (Ext.)/Vapor Barrier-B lack Vapor Barrier M 1280 S F E A-01,E A-02,E A-03,E A-04
21 Concrete/D riveway-B lack Driveway M 680 S F E A-02
22 Caulk/Exterior-White Exterior M 299 LF E A-01,E A-02,E A-03,E A-04
23 Concrete/Wall-Grey Wall M 890 S F E A-02,E A-01,E A-03,E A-04
24 Roofing/Asphalt (Shingles)-B lack Asphalt (Shingles) M 1150
S F E A-05
25 Roofing/Asphalt (Shingles)-B lack Asphalt (Shingles) M 1150
S F E A-05
26 Roofing/Tar Paper-B lack Tar Paper M 1150 S F E A-05
27 Roofing/Asphalt (Shingles)-B lack Asphalt (Shingles) M 680 S F E A-10
28 Roofing/Asphalt (Shingles)-B lack Asphalt (Shingles) M 680 S F E A-10
29 Roofing/Tar Paper-B lack Tar Paper M 680 S F E A-10
30 Concrete/Garage-Grey Garage M 520 S F F S-12
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive Romulus, Michigan 48174
(734) 955-6600
Fax: (734) 955-6604
To:
Attention:
Environmental Testing And Consulting Inc.
38900 Huron River Drive
Romulus, MI 48174
Project Location: 21610 Lyndon St, Detroit, MI 48223
REVISED REPORT
Client Project: 293027
293027ETL Job:
Al Dyer
Report Issued: 08/12/2026
Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst
1917247 Asbestos1A 08/12/2026 Erica Marcos08/07/2026
1917248 Asbestos1B 08/12/2026 Erica Marcos08/07/2026
1917249 Asbestos1C 08/12/2026 Erica Marcos08/07/2026
1917250 Asbestos2A 08/12/2026 Erica Marcos08/07/2026
1917251 Asbestos2B 08/12/2026 Erica Marcos08/07/2026
1917252 Asbestos2C 08/12/2026 Erica Marcos08/07/2026
1917253 Asbestos3A 08/12/2026 Erica Marcos08/07/2026
1917254 Asbestos3B 08/12/2026 Erica Marcos08/07/2026
1917255 Asbestos3C 08/12/2026 Erica Marcos08/07/2026
1917256 Asbestos4A 08/12/2026 Erica Marcos08/07/2026
1917257 Asbestos4B 08/12/2026 Erica Marcos08/07/2026
1917258 Asbestos4C 08/12/2026 Erica Marcos08/07/2026
1917259 Asbestos5A 08/12/2026 Erica Marcos08/07/2026
1917260 Asbestos5B 08/12/2026 Erica Marcos08/07/2026
1917261 Asbestos5C 08/12/2026 Erica Marcos08/07/2026
1917262 Asbestos6A 08/12/2026 Erica Marcos08/07/2026
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this information in error, please notify ETL immediately. Thank you.
Lab Sample Number Client Sample Number Sample Type CompletedSampled Analyst
1917263 Asbestos6B 08/12/2026 Erica Marcos08/07/2026
1917264 Asbestos6C 08/12/2026 Erica Marcos08/07/2026
1917265 Asbestos7A 08/12/2026 Erica Marcos08/07/2026
1917266 Asbestos7B 08/12/2026 Erica Marcos08/07/2026
1917267 Asbestos7C 08/12/2026 Erica Marcos08/07/2026
1917268 Asbestos8A 08/12/2026 Erica Marcos08/07/2026
1917269 Asbestos8B 08/12/2026 Erica Marcos08/07/2026
1917270 Asbestos8C 08/12/2026 Erica Marcos08/07/2026
1917271 Asbestos9A 08/12/2026 Ben Jones08/07/2026
1917272 Asbestos9B 08/12/2026 Ben Jones08/07/2026
1917273 Asbestos9C 08/12/2026 Ben Jones08/07/2026
1917274 Asbestos10A 08/12/2026 Ben Jones08/07/2026
1917275 Asbestos10B 08/12/2026 Ben Jones08/07/2026
1917276 Asbestos10C 08/12/2026 Ben Jones08/07/2026
1917277 Asbestos11A 08/12/2026 Ben Jones08/07/2026
1917278 Asbestos11B 08/12/2026 Ben Jones08/07/2026
1917279 Asbestos11C 08/12/2026 Ben Jones08/07/2026
1917280 Asbestos12A 08/12/2026 Ben Jones08/07/2026
1917281 Asbestos12B 08/12/2026 Ben Jones08/07/2026
1917282 Asbestos12C 08/12/2026 Ben Jones08/07/2026
1917283 Asbestos13A 08/12/2026 Ben Jones08/07/2026
1917284 Asbestos13B 08/12/2026 Ben Jones08/07/2026
1917285 Asbestos13C 08/12/2026 Ben Jones08/07/2026
1917286 Asbestos14A 08/12/2026 Ben Jones08/07/2026
1917287 Asbestos14B 08/12/2026 Ben Jones08/07/2026
1917288 Asbestos14C 08/12/2026 Ben Jones08/07/2026
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this
1917289 Asbestos15A 08/12/2026 Ben Jones08/07/2026
1917290 Asbestos15B 08/12/2026 Ben Jones08/07/2026
1917291 Asbestos15C 08/12/2026 Ben Jones08/07/2026
1917292 Asbestos16A 08/12/2026 Ben Jones08/07/2026
1917293 Asbestos16B 08/12/2026 Ben Jones08/07/2026
1917294 Asbestos16C 08/12/2026 Ben Jones08/07/2026
1917295 Asbestos17A 08/12/2026 Ben Jones08/07/2026
1917296 Asbestos17B 08/12/2026 Ben Jones08/07/2026
1917297 Asbestos17C 08/12/2026 Ben Jones08/07/2026
1917298 Asbestos18A 08/12/2026 OJ Ivey08/07/2026
1917299 Asbestos18B 08/12/2026 OJ Ivey08/07/2026
1917300 Asbestos18C 08/12/2026 OJ Ivey08/07/2026
1917301 Asbestos19A 08/12/2026 OJ Ivey08/07/2026
1917302 Asbestos19B 08/12/2026 OJ Ivey08/07/2026
1917303 Asbestos19C 08/12/2026 OJ Ivey08/07/2026
1917304 Asbestos20A 08/12/2026 OJ Ivey08/07/2026
1917305 Asbestos20B 08/12/2026 OJ Ivey08/07/2026
1917306 Asbestos20C 08/12/2026 OJ Ivey08/07/2026
1917307 Asbestos21A 08/12/2026 OJ Ivey08/07/2026
1917308 Asbestos21B 08/12/2026 OJ Ivey08/07/2026
1917309 Asbestos21C 08/12/2026 OJ Ivey08/07/2026
1917310 Asbestos22A 08/12/2026 OJ Ivey08/07/2026
1917311 Asbestos22B 08/12/2026 OJ Ivey08/07/2026
1917312 Asbestos22C 08/12/2026 OJ Ivey08/07/2026
1917313 Asbestos23A 08/12/2026 OJ Ivey08/07/2026
1917314 Asbestos23B 08/12/2026 OJ Ivey08/07/2026
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this
1917315 Asbestos23C 08/12/2026 OJ Ivey08/07/2026
1917316 Asbestos24A 08/12/2026 Teagan Murphy08/07/2026
1917317 Asbestos24B 08/12/2026 Teagan Murphy08/07/2026
1917318 Asbestos24C 08/12/2026 Teagan Murphy08/07/2026
1917319 Asbestos25A 08/12/2026 Teagan Murphy08/07/2026
1917320 Asbestos25B 08/12/2026 Teagan Murphy08/07/2026
1917321 Asbestos25C 08/12/2026 Teagan Murphy08/07/2026
1917322 Asbestos26A 08/12/2026 Teagan Murphy08/07/2026
1917323 Asbestos26B 08/12/2026 Teagan Murphy08/07/2026
1917324 Asbestos26C 08/12/2026 Teagan Murphy08/07/2026
1917325 Asbestos27A 08/12/2026 Teagan Murphy08/07/2026
1917326 Asbestos27B 08/12/2026 Teagan Murphy08/07/2026
1917327 Asbestos27C 08/12/2026 Teagan Murphy08/07/2026
1917328 Asbestos28A 08/12/2026 Teagan Murphy08/07/2026
1917329 Asbestos28B 08/12/2026 Teagan Murphy08/07/2026
1917330 Asbestos29A 08/12/2026 Teagan Murphy08/07/2026
1917331 Asbestos29B 08/12/2026 Teagan Murphy08/07/2026
1917332 Asbestos29C 08/12/2026 Teagan Murphy08/07/2026
1917333 Asbestos30A 08/12/2026 Teagan Murphy08/07/2026
1917334 Asbestos30B 08/12/2026 Teagan Murphy08/07/2026
1917335 Asbestos30C 08/12/2026 Teagan Murphy08/07/2026
Reviewed by:
Summary
Sample Layer MasticMethod
PLM 87
Point Count 5
Dawson Bradley
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this
Revision History
Revision CommentRevised ByRevised Date
Dawson Bradley QC Change08/13/2026
This report is intended for use solely by the individual or entity to which it is addressed. This report may not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. It may contain information that is privileged, confidential and otherwise exempt by law from disclosure. If the reader of this information is not the intended recipient or an employee of its intended recipient, you are herewith notified that any dissemination, distribution or copying of this information is strictly prohibited. If you have received this
Certificate of Analysis
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
21610 Lyndon St, Detroit, MI 48223
ETL Job :
Client Project :
293027
293027
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
08/07/2026
08/07/2026
Date Collected :
Date Received :
PLM None Detected 1917247
1A PLM 100% OtherPLM Trace CelluloseGreyConcrete / Floor - Grey - HA(1)
Non-Fibrous
HomogenousFS1
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
PLM None Detected 1917248
1B PLM 100% OtherPLM Trace CelluloseGreyConcrete / Floor - Grey - HA(1)
Non-Fibrous
HomogenousFS2
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
PLM None Detected 1917249
1C PLM 100% OtherPLM Trace CelluloseGreyConcrete / Floor - Grey - HA(1)
Non-Fibrous
HomogenousFS1
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
PLM 2% Chrysotile1917250
2A PLM 98% OtherPLM Trace CelluloseCreamBasement Window Glaze -
Cream - HA(2) Non-Fibrous
HomogenousEA2
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
1917251
2B
Positive Stop
EA3
Analyst: Erica Marcos
Date Analyzed : 08/12/2026
Sample Not Analyzed
1917252
2C
Positive Stop
EA4
Analyst: Erica Marcos
Date Analyzed : 08/12/2026
Sample Not Analyzed
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
21610 Lyndon St, Detroit, MI 48223
ETL Job :
Client Project :
293027
293027
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
08/07/2026
08/07/2026
Date Collected :
Date Received :
PLM None Detected 1917253
3A PLM 100% OtherGreenFloor / Tile - Green - HA(3)
Non-Fibrous
HomogenousFS3
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
PLM None Detected 1917254
3B PLM 100% OtherGreenFloor / Tile - Green - HA(3)
Non-Fibrous
HomogenousFS4
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
PLM None Detected 1917255
3C PLM 100% OtherGreenFloor / Tile - Green - HA(3)
Non-Fibrous
HomogenousFS3
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
PLM None Detected 1917256
4A PLM 100% OtherPLM Trace CelluloseClearFloor / Tile Mastic - Clear -
HA(4) Non-Fibrous
HomogenousFS3
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
PLM None Detected 1917257
4B PLM 100% OtherPLM Trace CelluloseClearFloor / Tile Mastic - Clear -
HA(4) Non-Fibrous
HomogenousFS4
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
PLM None Detected 1917258
4C PLM 100% OtherPLM Trace CelluloseClearFloor / Tile Mastic - Clear -
HA(4) Non-Fibrous
HomogenousFS3
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
21610 Lyndon St, Detroit, MI 48223
ETL Job :
Client Project :
293027
293027
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
08/07/2026
08/07/2026
Date Collected :
Date Received :
PLM None Detected 1917259
5A PLM 100% OtherBrownFloor / Tile - Brown - HA(5)
Non-Fibrous
HomogenousFS3
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
PLM None Detected 1917260
5B PLM 100% OtherBrownFloor / Tile - Brown - HA(5)
Non-Fibrous
HomogenousFS4
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
PLM None Detected 1917261
5C PLM 100% OtherBrownFloor / Tile - Brown - HA(5)
Non-Fibrous
HomogenousFS3
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
PLM None Detected 1917262
6A PLM 100% OtherPLM Trace CelluloseBrownFloor / Tile Mastic - Brown -
HA(6) Non-Fibrous
HomogenousFS3
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
PLM None Detected 1917263
6B PLM 100% OtherPLM Trace CelluloseBrownFloor / Tile Mastic - Brown -
HA(6) Non-Fibrous
HomogenousFS4
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
PLM None Detected 1917264
6C PLM 100% OtherPLM Trace CelluloseBrownFloor / Tile Mastic - Brown -
HA(6) Non-Fibrous
HomogenousFS3
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
21610 Lyndon St, Detroit, MI 48223
ETL Job :
Client Project :
293027
293027
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
08/07/2026
08/07/2026
Date Collected :
Date Received :
PC 0.75% Chrysotile1917265
7A PC 99.25% OtherCreamFloor / Tile - Cream - HA(7)
Non-Fibrous
HomogenousFS3
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
PC 0.25% Chrysotile1917266
7B PC 99.75% OtherCreamFloor / Tile - Cream - HA(7)
Non-Fibrous
HomogenousFS4
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
PC 0.5% Chrysotile1917267
7C PC 99.5% OtherCreamFloor / Tile - Cream - HA(7)
Non-Fibrous
HomogenousFS3
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
PLM None Detected 1917268
8A PLM 100% OtherPLM Trace CelluloseClear/BrownFloor / Tile Mastic - Clear -
HA(8) Non-Fibrous
HomogenousFS3
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
PLM None Detected 1917269
8B PLM 100% OtherPLM Trace CelluloseClear/BrownFloor / Tile Mastic - Clear -
HA(8) Non-Fibrous
HomogenousFS4
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
PLM None Detected 1917270
8C PLM 100% OtherPLM Trace CelluloseClear/BrownFloor / Tile Mastic - Clear -
HA(8) Non-Fibrous
HomogenousFS3
Layer-1 Analyst: Erica Marcos
Date Analyzed : 08/12/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
21610 Lyndon St, Detroit, MI 48223
ETL Job :
Client Project :
293027
293027
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
08/07/2026
08/07/2026
Date Collected :
Date Received :
PLM None Detected 1917271
9A PLM 100% OtherPLM Trace CelluloseBrownAdhesive / - - Brown - HA(9)
Non-Fibrous
HomogenousFS4
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917272
9B PLM 100% OtherPLM Trace CelluloseBrownAdhesive / - - Brown - HA(9)
Non-Fibrous
HomogenousFS4
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917273
9C PLM 100% OtherPLM Trace CelluloseBrownAdhesive / - - Brown - HA(9)
Non-Fibrous
HomogenousFS4
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917274
10A PLM 100% OtherPLM Trace CelluloseWhiteCaulk / Interior - White - HA(10)
Non-Fibrous
HomogenousFS4
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917275
10B PLM 100% OtherPLM Trace CelluloseWhiteCaulk / Interior - White - HA(10)
Non-Fibrous
HomogenousFS7
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917276
10C PLM 100% OtherPLM Trace CelluloseWhiteCaulk / Interior - White - HA(10)
Non-Fibrous
HomogenousFS4
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
21610 Lyndon St, Detroit, MI 48223
ETL Job :
Client Project :
293027
293027
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
08/07/2026
08/07/2026
Date Collected :
Date Received :
PLM None Detected 1917277
11A PLM 100% OtherPLM Trace CelluloseWhiteCeiling / Wall / Drywall
Composite - White - HA(11) Non-Fibrous
HomogenousFS3
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917278
11B PLM 100% OtherPLM Trace CelluloseWhiteCeiling / Wall / Drywall
Composite - White - HA(11) Non-Fibrous
HomogenousFS4
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PC Trace Chrysotile1917278
11B PC 100% OtherWhiteMud
Non-Fibrous
HomogenousFS4
Layer-2 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917279
11C PLM 100% OtherPLM Trace CelluloseWhiteCeiling / Wall / Drywall
Composite - White - HA(11) Non-Fibrous
HomogenousFS5
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PC 0.5% Chrysotile1917279
11C PC 99.25% OtherPC 0.25% CelluloseWhiteMud
Non-Fibrous
HomogenousFS5
Layer-2 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917280
12A PLM 100% OtherPLM Trace CelluloseBrownAdhesive / - - Brown - HA(12)
Non-Fibrous
HomogenousFS7
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
21610 Lyndon St, Detroit, MI 48223
ETL Job :
Client Project :
293027
293027
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
08/07/2026
08/07/2026
Date Collected :
Date Received :
PLM None Detected 1917281
12B PLM 100% OtherPLM Trace CelluloseBrownAdhesive / - - Brown - HA(12)
Non-Fibrous
HomogenousFS7
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917282
12C PLM 100% OtherPLM Trace CelluloseBrownAdhesive / - - Brown - HA(12)
Non-Fibrous
HomogenousFS7
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917283
13A PLM 9% OtherPLM Trace Cellulose
PLM 91% Fiberglass
YellowInsulation / Blown-in - Yellow -
HA(13) Fibrous
HomogenousFS11
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917284
13B PLM 9% OtherPLM Trace Cellulose
PLM 91% Fiberglass
YellowInsulation / Blown-in - Yellow -
HA(13) Fibrous
HomogenousFS11
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917285
13C PLM 9% OtherPLM Trace Cellulose
PLM 91% Fiberglass
YellowInsulation / Blown-in - Yellow -
HA(13) Fibrous
HomogenousFS11
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917286
14A PLM 100% OtherPLM Trace CelluloseGreyConcrete / Porch - Grey - HA(14)
Non-Fibrous
HomogenousEA1
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
21610 Lyndon St, Detroit, MI 48223
ETL Job :
Client Project :
293027
293027
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
08/07/2026
08/07/2026
Date Collected :
Date Received :
PLM None Detected 1917287
14B PLM 100% OtherPLM Trace CelluloseGreyConcrete / Porch - Grey - HA(14)
Non-Fibrous
HomogenousEA1
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917288
14C PLM 100% OtherPLM Trace CelluloseGreyConcrete / Porch - Grey - HA(14)
Non-Fibrous
HomogenousEA1
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917289
15A PLM 100% OtherPLM Trace CelluloseGreyConcrete / Walkway - Grey -
HA(15) Non-Fibrous
HomogenousEA1
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917290
15B PLM 100% OtherPLM Trace CelluloseGreyConcrete / Walkway - Grey -
HA(15) Non-Fibrous
HomogenousEA2
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917291
15C PLM 100% OtherPLM Trace CelluloseGreyConcrete / Walkway - Grey -
HA(15) Non-Fibrous
HomogenousEA3
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917292
16A PLM 100% OtherPLM Trace CelluloseRedWall (Ext.) / Brick - Red - HA(16)
Non-Fibrous
HomogenousEA1
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
21610 Lyndon St, Detroit, MI 48223
ETL Job :
Client Project :
293027
293027
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
08/07/2026
08/07/2026
Date Collected :
Date Received :
PLM None Detected 1917293
16B PLM 100% OtherPLM Trace CelluloseRedWall (Ext.) / Brick - Red - HA(16)
Non-Fibrous
HomogenousEA6
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917294
16C PLM 100% OtherPLM Trace CelluloseRedWall (Ext.) / Brick - Red - HA(16)
Non-Fibrous
HomogenousEA7
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917295
17A PLM 100% OtherPLM Trace CelluloseGreyMortar / Brick - Grey - HA(17)
Non-Fibrous
HomogenousEA1
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917296
17B PLM 100% OtherPLM Trace CelluloseGreyMortar / Brick - Grey - HA(17)
Non-Fibrous
HomogenousEA6
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM None Detected 1917297
17C PLM 100% OtherPLM Trace CelluloseGreyMortar / Brick - Grey - HA(17)
Non-Fibrous
HomogenousEA7
Layer-1 Analyst: Ben Jones
Date Analyzed : 08/12/2026
PLM 10% Chrysotile1917298
18A PLM 83% OtherPLM 7% CelluloseWhiteTransite / Siding - White -
HA(18) Non-Fibrous
HomogenousEA2
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/12/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
21610 Lyndon St, Detroit, MI 48223
ETL Job :
Client Project :
293027
293027
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
08/07/2026
08/07/2026
Date Collected :
Date Received :
1917299
18B
Positive Stop
EA3
Analyst: OJ Ivey
Date Analyzed : 08/12/2026
Sample Not Analyzed
1917300
18C
Positive Stop
EA4
Analyst: OJ Ivey
Date Analyzed : 08/12/2026
Sample Not Analyzed
PLM None Detected 1917301
19A PLM 90% OtherPLM 10% CelluloseBlackTransite Seam Tape - Black -
HA(19) Fibrous
HomogenousEA2
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/12/2026
PLM None Detected 1917302
19B PLM 90% OtherPLM 10% CelluloseBlackTransite Seam Tape - Black -
HA(19) Fibrous
HomogenousEA3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/12/2026
PLM None Detected 1917303
19C PLM 90% OtherPLM 10% CelluloseBlackTransite Seam Tape - Black -
HA(19) Fibrous
HomogenousEA4
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/12/2026
PLM None Detected 1917304
20A PLM 90% OtherPLM 10% CelluloseBlackWall (Ext.) / Vapor Barrier -
Black - HA(20) Fibrous
HomogenousEA2
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/12/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
21610 Lyndon St, Detroit, MI 48223
ETL Job :
Client Project :
293027
293027
Environmental Testing Laboratories, Inc.
37575 W Huron River Drive
Romulus, Michigan 48174
(734) 955-6600, Fax: (734) 955-6604
Sample Description Appearance % Fibrous % Non-Fibrous % Asbestos
08/07/2026
08/07/2026
Date Collected :
Date Received :
PLM None Detected 1917305
20B PLM 90% OtherPLM 10% CelluloseBlackWall (Ext.) / Vapor Barrier -
Black - HA(20) Fibrous
HomogenousEA3
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/12/2026
PLM None Detected 1917306
20C PLM 90% OtherPLM 10% CelluloseBlackWall (Ext.) / Vapor Barrier -
Black - HA(20) Fibrous
HomogenousEA4
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/12/2026
PLM None Detected 1917307
21A PLM 99% OtherPLM 1% CelluloseBlackConcrete / Driveway - Black -
HA(21) Non-Fibrous
HomogenousEA2
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/12/2026
PLM None Detected 1917308
21B PLM 99% OtherPLM 1% CelluloseBlackConcrete / Driveway - Black -
HA(21) Non-Fibrous
HomogenousEA2
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/12/2026
PLM None Detected 1917309
21C PLM 99% OtherPLM 1% CelluloseBlackConcrete / Driveway - Black -
HA(21) Non-Fibrous
HomogenousEA2
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/12/2026
PLM None Detected 1917310
22A PLM 98% OtherPLM 2% CelluloseWhiteCaulk / Exterior - White - HA(22)
Non-Fibrous
HomogenousEA1
Layer-1 Analyst: OJ Ivey
Date Analyzed : 08/12/2026
ETL, Inc. maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced without written approval by ETL, Inc. Test Method EPA 600/R-93-116 & EPA 600/M4-82/020 or NYSDOH-ELAP item 198.1 and/or 198.6 was used to analyze all samples. Matrix interference and/or resolution limits (i.e. detecting asbestos in non-friable organically bound materials) may yield false results in certain circumstances. Quantitative transmission electron microscopy (TEM) is currently the only method that can pronounce materials as non-asbestos containing. Interpretation and use of test results are the responsibility of the client. ETL, Inc. is not responsible for the accuracy of the results when requested to physically separate and analyze layered samples. Any
PLM results below 10% should be re-analyzed using the EPA recommended Point Count method. Any material that has greater than 1% asbestos content is considered to be an Asbestos Containing Material (ACM). These materials are regulated by both OSHA and the EPA and must be treated accordingly. Results are related to only to samples that were tested. An estimate of uncertainty can be provided at the client's request.
Polarized Light Microscopy Asbestos Analysis Report
Location :
To :
Romulus,MI 48174
Environmental Testing And Consulting Inc.
38900 Huron River Drive
21610 Lyndon St, Detroit, MI 48223
ETL Job :
Client Project :
293027
293027
Environmental Testing…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .