216007B TC SOB-ADDENDUM 01 22july2026 ISSUED 171-23058-rlo.pdf
PDF 9 MB Posted
- Solicitation number
- RFQ 171 260000000366 4
- Issued by
- Grand Traverse County, Michigan
About this file
This Addendum No. 1, issued July 22, 2026, by Kendra C. Thompson Architects for the State of Michigan Department of Technology, Management & Budget (DTMB), pertains to the Traverse City State Office Building Bathroom and Plumbing Upgrade Project located at 701 S. Elmwood, Traverse City, Michigan. The project scope encompasses bathroom renovations, plumbing sanitary and water piping replacement, and associated plumbing, mechanical, and electrical improvements. A mandatory pre-bid conference was held on July 20, 2026, at 11:00 a.m., with attendance required for bid consideration. Key clarifications include corrections to door frame types and details on Drawing Sheet A101, construction protection responsibilities, preliminary construction phasing allowing simultaneous work on floors 1-4 with owner-vacated wings, and demolition requirements for all existing features to achieve design intent. The addendum also clarifies revised plumbing and mechanical drawings and fire alarm panel location. Bids are due Wednesday, August 5, 2026, at 2:00 p.m. Eastern Time via electronic submission through the SIGMA VSS website, with a single PDF package not exceeding 25.0 MB.
Contract requirements include submission of bid forms from the Project Manual, a 5% bid bond, performance and payment bonds for bids exceeding $50,000, and a $100,000 provisional contingency allowance in the base bid. Substantial completion is required within 280 calendar days from the Notice-to-Proceed or by June 22, 2027, with liquidated damages of $1,000 per calendar day for delays. A 10% preference applies to Qualified Disabled Veteran-Owned Companies with appropriate documentation. At least 50% of all working employees must be Michigan residents, and prevailing wage rates are required with certified payroll submitted directly to the Department of Labor and Economic Opportunity. Progress payments are processed no more than once per month. Award will be made to the responsive and responsible best value bidder as recommended by Kendra Thompson Architects. The contract documents include comprehensive architectural, plumbing, mechanical, and fire protection drawings across multiple levels, with multiple alternates available for contractor discretion subject to owner approval.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
803 cherry street manistee, mi 49660 ■ t: 231.723.4195 ■ thompson.kendra@sbcglobal.net ■ www.kendrathompson-architects.com kendra c.
THOMPSON
architects, p.c.
ADDENDUM NO. 1
TRAVERSE CITY STATE OFFICE BUILDING DATE: 7/22/2026
BATHROOM & PLUMBING UPGRADE PROJECT SOM: File #171/23085.RLO 701 S. ELMWOOD TRAVERSE CITY, MI KTA: Job #216007B
The following items are changes, additions, deletions and/or clarifications of the drawings and specifications, and shall be included in the Bid Proposal. All of items will be a part of the Construction Documents. Acknowledge receipt of this Addendum in the appropriate space on the Bid Proposal form. Failure to do so may result in disqualification of the bid.
Item No. 1: Pre-Bid Meeting:
A mandatory Pre-Bid Conference was held on July 20, 2026, at 11:00 a.m. Refer to attached Meeting
Agenda and Attendance Record.
Item No. 2: Clarification: Door Schedule, Frame Types – Refer to Drawing Sheet A101
Clarification: Doors indicated to have HM frames are manufactured access door units. Typical man doors are to be wood frames as indicated to match existing installed conditions.
Item No. 3: Revise and Add: Door Schedule, Details – Refer to Drawing Sheet A101
Revise and Add: Door details were incorrectly identified, and additional jamb and head details have been added to reflect the design intent. Refer to revised drawing Sheet A101.
Item No. 4: Clarification: Construction Protection
Clarification: Contractor responsible for providing adequate protection of existing materials during construction, including but not limited to temporary floor protection. Owner will make available elevator wall protection pads for Contractor use when transporting materials.
Item No. 5: Clarification: Construction Phasing
Clarification: Preliminary construction phasing is as outlined below, subject to final review at Pre- Construction Meeting.
1. Owner intends to vacate north (or south) wings of building for contractor use in simultaneous work occurring on Floors 1-4.
2. Upon completion of north (or south) wing, Owner will vacate the remaining wing for contractor use.
3. Alternate #1 – Ground Floor Staff Shower Room #008 may be phased per Contractor’s discretion upon approval and coordination with Owner.
4. Alternate #2 – Ground Floor, North Wing work may be phased per Contractor’s discretion upon approval and coordination with Owner and DHHS. This work area will be vacated however the DHHS office areas will remain actively in operation. Contractor shall plan to complete work of this area in a timely manner so as to minimize DHHS disruption.
Item No. 6: Clarification: Demolition – Refer to Drawing Sheets A204, A205, A206, A208, A209, A211, A212, A214 and A215.
Clarification: Contractor responsible for removal of all existing features, whether specifically identified on drawings or not, as required to complete project in accordance with design intent outlined. Existing terrazzo threshold(s) and other thresholds shall be removed and surface(s) prepped appropriately to allow for smooth transition of flooring surfaces.
803 cherry street manistee, mi 49660 ■ t: 231.723.4195 ■ thompson.kendra@sbcglobal.net ■ www.kendrathompson-architects.com
Addendum No. 1 TC SOB Bath & Plmb’g Project 7/22/2026
Item No. 7: Clarification: Plumbing and Mechanical Drawings
Clarification: Refer to revised Plumbing and Mechanical drawings reissued to clarify keyed notes.
Refer to drawings Sheets FP200, FP201, FP202, P100, PD200, PD201, PD202, P200, P201, P202, P203, P204, P205, P206, P207, P300, P301, P302, M100, MD200, MD201, MD202, M200, M201, M202, M203, M204, M205, M206, M207, M300, M301 and M302.
Item No. 8: Clarification: Fire Alarm Panel – Reference Drawing Sheet E201 Clarification: Honeywell main fire alarm panel is location on north wall of Lobby #100.
END OF ADDENDUM NO. 1
Attachment: Pre-Bid Meeting Agenda Pre-Bid Attendance Record
Drawing Sheets A101, FP200, FP201, FP202, P100, PD200, PD201, PD202, P200, P201, P202, P203, P204, P205, P206, P207, P300, P301, P302, M100, MD200, MD201, MD202, M200, M201, M202, M203, M204, M205, M206, M207, M300, M301 and M302.
Pre-Bid Agenda 751/23085.RLO
Mandatory Pre-Bid Meeting Agenda Department of Natural Resources
Traverse City State Office Building Bathroom & Plumbing Upgrade Project
751/23085.RLO
July 20, 2026, at 11:00 am
1. Introductions:
Ronda Osga – DTMB / Design and Construction Division / Project Director Brian Guigue – DTMB / Design and Construction Division / Field Representative Luke Krzeminski – DTMB / Building Operations / West Zone Facilities Supervisor Paul Charles – DTMB / Building Operations / Facilities Supervisor Kendra Thompson – Kendra Thompson Associates / Project Manager
2. This is a Mandatory Pre-Bid Meeting; you should confirm your attendance is recorded to ensure your bid is considered. You must sign under the same name as the company submitting the bid. An individual is only permitted to represent one bidder at a mandatory Pre-Bid Conference.
3. Project Description:
Bathroom renovations, plumbing sanitary and water piping replacement, and associated plumbing, mechanical and electrical improvements as related to the bathroom renovations.
4. Bids are due Wednesday, August 5, 2026, at 2:00 PM Eastern Time via electronic submission through the SIGMA VSS website at:
https://sigma.michigan.gov/webapp/PRDVSS2X1/AltSelfService
Please package your bid submittal into a single PDF document, or at least as few separate documents as possible, per the 25.0 MB maximum file size limitation.
This will facilitate the bids processing and minimize chances of errors
If you experience issues or have questions regarding your electronic submission, bidders must contact the SIGMA Help Desk for assistance. Bidders can contact the Help Desk by calling 888-734-9749 or emailing sigma-procurement-helpdesk@michigan.gov or sigma-vendor@michigan.gov
Please notify the Office of Design and Construction (DCD) if you are having SIGMA VSS issues. Include your SIGMA ticket number in an email to our contract specialists, Anne Watros (watrosa@michigan.gov) and Don Klein (kleind4@michigan.gov). You may be asked to email your bid package. Emailed submissions require DCD approval and will be handled on a case-by-case basis.
Approved emailed submissions MUST be received prior to the 2:00 p.m. deadline to be considered responsive and responsible.
5. Bids must be submitted on the Bid Summary form enclosed within the Project Manual. The bid must also include forms within the Project Manual including:
https://sigma.michigan.gov/webapp/PRDVSS2X1/AltSelfService mailto:sigma-procurement-helpdesk@michigan.gov mailto:sigma-procurement-helpdesk@michigan.gov mailto:sigma-vendor@michigan.gov mailto:watrosa@michigan.gov mailto:kleind4@michigan.gov
• Qualified Disabled Veteran (QDV) Business Representation
• Certification of a Michigan Based Business
• Responsibility Certification
• Bid Schedule (include Schedule of Alternates)
• Bid Security in the amount of 5% of the Base Bid Price,
• Performance and Payment Bonds (To be submitted by Successful Contractor)
• State Project Registration (SPR) LEO Wage and Hour
6. A Performance Bond and a Payment Bond are required for bids in excess of $50,000.00. A five percent (5%) Bid Bond is required with all your bid submittals.
7. Allowances should be included in the base bid (See Sect 0100, Article 10).
Allowances. $100,000 Provisional Contingency Allowance (Bid Schedule form).
8. Time of Completion and Liquidated Damages: Work of all trades as specified in the Contract Documents must be completed 280 calendar days from the Notice-to-Proceed or by June 22, 2027 based on the Notice-to-Proceed except for minor replacement, correction, or adjustment items which do not interfere with the complete operation and utilization of all parts of the Contract Work. This Contract Time is of the essence and liquidated damages for each Calendar Day that expires after this Substantial Completion of the entire Work must be in the amount of $1,000.00. (See Section 00500, Article 4).
9. A 10% preference will be given in the award of this project to Qualified Disabled
Veteran Owned Companies in accordance with Public Act 22 of 2010 (See Section 00100, Article14.1.2). To be considered, a bidder must include with their bid a DD214 Proof of Service and Discharge, a Veterans Administration Rating decision letter, proof of disability (if the disability is not included on the DD 214) and appropriate legal documents setting forth the 51% natural persons QDV Ownership.
10. Progress payments will be processed not more than once per month.
11. Award of Contract: Awarded to the responsive and responsible best value bidder as recommended by Kendra Thompson Architects (Section 00100, Article14.1.1).
12. At least 50% of all working employees must be Michigan residents.
13. Prevailing Wage Rates are required for this project. Certified payroll to be submitted directly to the Department of Labor and Economic Opportunity via the online submission process. Certified payroll is not to be submitted to DTMB at any time. (See Section 00700 General Conditions – Article 7.14).
14. Superintendent of the project shall have the authority of the construction company to make on site decisions. On site presence is required whenever work is occurring even if it is a sub-contractor (See Section 00700 General Conditions
– Article 4.2).
15. Site Walk-Through and Bidder Questions: A site walk-through will take place after this meeting. If you have questions concerning bid submittal or terms and conditions of the contract agreement, please submit them by Monday, July 27, 2026, at 5:00 pm ET by e-mail to:
Kendra Thompson thompson.kendra@sbcglobal.net
(231) 723-4195 office
(231) 510-5012 mobile
2x4 WOOD NAILER
WOOD FRAME BY
DOOR TYPE - REFER
TO DOOR SCHEDULE
1x4 WOOD CASING - CUSTOM
5/8" GYP. BRD.
3-1/2" METAL STUDS @ 16" O.C.
DOOR MANUFACTURER
5/8" GYP. BRD.
31 2
5 8
5 8
SHIM
1x4 WOOD CASING - CUSTOM
WOOD DOOR STOP
2" 5
8"5 8"
2x4 WOOD NAILER
WOOD FRAME BY
DOOR TYPE - REFER
TO DOOR SCHEDULE
5/8" GYP. BRD.
3-1/2" METAL STUDS @ 16" O.C.
DOOR MANUFACTURER
5/8" GYP. BRD.
PROFILE TO MATCH EXIST'G.
WOOD DOOR STOP
SHIM
PROFILE TO MATCH EXIST'G.
PROFILE TO MATCH EXIST'G.
1x4 WOOD CASING - CUSTOM
(45 d. MITER TO JAMB CASING)
SOUND ATTENUATION BLANKET
SOUND ATTENUATION BLANKET
SEE
SCHEDULE
S
EE
S C H
ED
U
LE
BA
SEE
SCHED.
S
EE
S C H
ED
PREFAB ACCESS
PANEL W/INTREGAL
FRAME & SCREW
KEY LOCK
2"
SEE
2"
S
EE
S C
H
ED
U
LE
" SCHEDULE
TYPICAL MATERIAL/THRESHOLD TRANSITIONS
DOOR (WHERE APPLICABLE)
ADA METAL TRANSITION STRIP
SEALED CONCRETE
CARPET TO HARD TILE TRANSITION CARPET TO SEALED CONC. TRANSITION
HARD TILE TO HARD TILE TRANSITION
CARPET AS SPECIFIED
CENTERLINE OF DOOR LEAF
HARD TILE AS SPECIFIED
CENTERLINE OF DOOR LEAF
CARPET AS SPECIFIED
CENTERLINE OF DOOR LEAF DOOR (WHERE APPLICABLE)
ADA METAL TRANSITION STRIP
CERAMIC TILE AS SPECIFIED
DOOR (WHERE APPLICABLE)
FLUSH METAL TRANSITION STRIP
HARD TILE AS SPECIFIED
3 8
EQ. EQ.
EQ. EQ. EQ. EQ.
3 8 " 3 8
"5/8" GYP. BRD.
1/2" FURR'G.
EXIST'G. C.M.U.
EXIST'G. C.M.U.
TO REMAIN
ACCESS PANEL -
SEE DOOR SCHEDULE
1 8
" V
.I.
F.
1 8 " V
.I.
F.
FINISH C.M.U. @
OPN'G. SMOOTH
5/8" GYP. BRD.
1/2" FURR'G.
EXIST'G. C.M.U.
BY ACCESS DOOR
MANUFACTURER
ACCESS PANEL -
SEE DOOR SCHEDULE
8"6" V.I.F.
8" V.I.F.
FINISH C.M.U. @
OPN'G. SMOOTH
STEEL FRAME
5/8" GYP. BRD.
3-1/2" METAL STUDS @ 16" O.C.
EXPOSED CONSTRUCTION
31 2
5 8
METAL STUD
@ JAMB & SILL
ACCESS PANEL -
SEE DOOR SCHEDULE
EXPOSED CONSTR.
FRAMED METAL
STUD OPEN'G.
5/8" GYP. BRD.
3-1/2" METAL STUDS @ 16" O.C.
EXPOSED CONSTRUCTION
2" 5
8"
EXPOSED CONSTR.
FRAMED METAL
STUD OPEN'G.
BY ACCESS DOOR
MANUFACTURER
ACCESS PANEL -
SEE DOOR SCHEDULE
STEEL FRAME DR. SCHEDULES
C op yr ig ht
Ke nd ra C
. T ho m ps on A rc hi te ct s, P
.C
UPGRADE PROJECT FOR:
MICHIGAN
MI FILE NO. 171/23058.RLO
STATE OF
OFFICE BLDG.
701 S. ELMWOOD - TRAVERSE CITY, MI
BATHROOM & PLUMBING
kendra c.
architects, p.c.
THOMPSON
803 Cherry Street Manistee, MI 49660 tel: 231.723.4195 thompson.kendra@sbcglobal.net www.kendrathompson-architects.com
A101
DRAWING TITLE
KCT PROJECT NO.DRAWN
KCT
REVIEWED
KCT
DATE
SCALE
AS NOTED
DRAWING NO.
SEAL
SHEET NO.
NO. REVISIONS / SUBMISSIONS DATE
PROJECT NAME
ROOM FINISH &
1 FACILITY ASSESSMENT/SD CONCEPTS 6/6/2025
2 SD REV. #01 6/25/2025
3 SD REV. #02 7/16/2025
4 DD 7/30/2025
5 CD - 50% REVIEW SET: VOID 8/27/2025
6 DESIGN DEVELOPMENT SET 9/24/2025
7 CD - 50% REVIEW SET 4/29/2026
8 CD - 90% REVIEW SET 6/5/2026
9 BCC PLAN REVIEW SET 6/17/2026
10 BID SET 6/26/2026
11 ADDENDUM NO. 1 7/22/2026
JUNE 2025
KT-216007C
DOOR TYPES:
SCALE: 3" = 1'-0"
JAMB1
A101 SCALE: 3" = 1'-0"
HEAD2
A101
FRAME TYPES:
FRAME
TYPEMAT. GLASS
DOOR
LOCATIOND
O O
R N
O
DOOR SCHEDULE
TYPE
DETAIL
MAT. GLASS HEAD JAMB SILL HARDW. RATING REMARKS
A - HMWD
B HMHM
B - HMHM
- HMWD -
A - 1 HMWD -
B - HMHM -
B
SIZE
A - 1 HMWD -
A - 1 HMWD
FIRE
LO
C A
TI
O N
LE
V
EL
-G
3'-0" x 6'-8" x 1 3/4"
3'-0" x 6'-8" x 1 3/4"
3'-0" x 6'-8" x 1 3/4"
3'-0" x 7'-0" x 1 3/4"
3'-0" x 7'-0" x 1 3/4"
18" x 32"
24" x 24"
3'-0" x 6'-8" x 1 3/4"
3'-0" x 7'-0" x 1 3/4"
A 1 -A
HMWD
- HMWD
A
-SMOKE-
2/A101 1/A101
ROOM FINISH SCHEDULE
026 STORAGE
UTR
STORAGE
STORAGE
OFFICE
CORRIDOR
STAFF SHOWER RM
CORRIDOR139
R O
O M
N O
NAME
STAIR #1S-1
ROOM
EXIST'G. TO REMAIN @4" VINYL @ RENOV.
BASE MT'L
WALL FLOOR
MT'L MT'L
WALL CL'G
REMARKS
UTR
UTR
UTR
WORK AREA
UTR
148 STORAGE
GYP. BOARD, PAINT
150 JANITOR CLOSET
6" H.T., COVED
EXIST'G. CONSTR. @
LO
C A
TI
O N
EXIST'G. EXPOSED,
HT-1
SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
EXIST'G. TERRAZZO
SCOPE IS LIMITED TO INFILL @ EXIST'G. TOIL RM DOOR ONLY
LE
V
EL
-1
LE
V
EL
-2
LE
V
EL
-3
152 WORK AREA
LE
V
EL
-4
026A STORAGE #026
025A UTR #025
STAFF SHOWER #008008A
145A
151A
143A UTR #143
UTR #145
WORK AREA #151
151B
142A
152A
140A UTR #140
UTR #142
152B
18" x 32"
24" x 24"
LE
V
EL
-1
LE
V
EL
-2
LE
V
EL
-3
330A OFFICE#330
LE
V
EL
-4
LE
V
EL
-G
EXIST'G. TERRAZZO EXIST'G. TO REMAIN
PAINT
4" VINYL @ NEW WALL
AREA ONLY
EXIST'G. EXPOSED/G.B.
@ NEW WALL ONLY, PAINT SCOPE IS LIMITED TO NEW G.B. WALL/DOOR & PAINTING OF ENTIRE AREA
EXIST'G. GLAZED CMU
TO REMAIN
EXIST'G. 2'X2' ACT
TO REMAIN
EXIST'G. VINYL W.B.
TO REMAIN
EXIST'G. CARPET TILES
TO REMAIN
2'X2' ACT-1/GYP. BD.
BLKHD, PAINT6" H.T., COVED HT-1
2'X2' ACT-1/GYP. BD.
BLKHD, PAINT
027 STAFF HALL CPT-1 2'X2' ACT-1/GYP. BD.
BLKHD, PAINT
4" VINYL - MATCH
EXIST'G, PAINT GYP. BOARD, PAINT
STAFF BREAK AREA035 GYP. BOARD, PAINT EXIST'G. 2'X2' ACT
TO REMAIN
4" VINYL @ RENOV.
AREA ONLY SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
4" WOOD - MATCH
EXIST'G, PAINT
CPT-1 @ RENOV. AREA;
EXIST'G CPT OTHERWISE
LOBBY100
4" WOOD - MATCH
EXIST'G, PAINT
GYP. BD. BLKHD, PAINT;
EXIST'G. ACT TO REMAIN SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
4" WOOD - MATCH
EXIST'G, PAINT GYP. BD/PLAST., PAINTEXIST'G. CARPET TILES
TO REMAIN
EXIST'G. 2'X2' ACT
TO REMAIN SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
6" H.T., COVED HT-1
6" H.T., COVED HT-1 2'X2' ACT-1/GYP. BD.
BLKHD, PAINT
CPT-1 GYP. BD. BLKHD,
PAINT
4" WOOD - MATCH
EXIST'G, PAINT GYP. BD/PLAST., PAINT
6" H.T., COVED HT-1
6" H.T., COVED HT-1 2'X2' ACT-1
2'X2' ACT-1
2'X2' ACT-1
CPT-1 GYP. BD. BLKHD,
PAINT
4" WOOD - MATCH
EXIST'G, PAINT GYP. BD/PLAST., PAINT
GYP. BD/PLAST @ RENOV.
CLOS. WALLS, PAINT RENOV. CLOS., PAINTCLOSET RENOV. CLOSET SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
4" VINYL @ RENOV. EXIST'G. CONSTR. @ GYP. BD/PLAST @ RENOV.
CLOS. WALLS, PAINT RENOV. CLOS., PAINTCLOSET/OFFICE
EA
S T
W
IN
G N O
R
TH
W
IN
G
MEETING ROOM122
EXIST'G. TO REMAIN @4" VINYL @ RENOV. EXIST'G. CONSTR. @ GYP. BD/PLAST @ RENOV.
CLOS. WALLS, PAINT RENOV. CLOS., PAINTCLOSET RENOV. CLOSET SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
CORRIDOR138
6" WOOD - MATCH
EXIST'G, PAINT GYP. BD/PLAST., PAINTEXIST'G. CARPET TILES
TO REMAIN
EXIST'G. 2'X2' ACT
TO REMAIN SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
S O
U
TH
W
IN
G
248 STORAGE
250 JANITOR CLOSET
LOBBY200
4" WOOD - MATCH
EXIST'G, PAINT
GYP. BD. BLKHD, PAINT;
EXIST'G. ACT TO REMAIN SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
4" VINYL @ RENOV. EXIST'G. CONSTR. @ GYP. BD/PLAST @ RENOV.
CLOS. WALLS, PAINT RENOV. CLOS., PAINTCLOSET/OFFICE
EA
S T
W
IN
G
UTR
STORAGE
STORAGE
OFFICE
CORRIDOR239
EXIST'G. TO REMAIN @4" VINYL @ RENOV.
UTR
UTR
WORK AREA
UTR
EXIST'G. CONSTR. @
252 WORK AREA
4" WOOD - MATCH
EXIST'G, PAINT GYP. BD/PLAST., PAINTEXIST'G. CARPET TILES
TO REMAIN
EXIST'G. 2'X2' ACT
TO REMAIN SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
6" H.T., COVED HT-1
6" H.T., COVED HT-1 2'X2' ACT-1/GYP. BD.
BLKHD, PAINT
GYP. BD. BLKHD,
PAINT
4" WOOD - MATCH
EXIST'G, PAINT GYP. BD/PLAST., PAINT
6" H.T., COVED HT-1
6" H.T., COVED HT-1 2'X2' ACT-1
2'X2' ACT-1
2'X2' ACT-1
GYP. BD. BLKHD,
PAINT
4" WOOD - MATCH
EXIST'G, PAINT GYP. BD/PLAST., PAINT
GYP. BD/PLAST @ RENOV.
CLOS. WALLS, PAINT RENOV. CLOS., PAINTCLOSET RENOV. CLOSET SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
N O
R
TH
W
IN
G
OFFICE222
EXIST'G. TO REMAIN @4" VINYL @ RENOV. EXIST'G. CONSTR. @ GYP. BD/PLAST @ RENOV.
CLOS. WALLS, PAINT RENOV. CLOS., PAINTCLOSET RENOV. CLOSET SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
CORRIDOR238
4" WOOD - MATCH
EXIST'G, PAINT GYP. BD/PLAST., PAINTEXIST'G. CARPET TILES
TO REMAIN
EXIST'G. 2'X2' ACT
TO REMAIN SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
S O
U
TH
W
IN
G
348 STORAGE
350 JANITOR CLOSET
LOBBY300
4" WOOD - MATCH
EXIST'G, PAINT
CPT-1 @ RENOV. AREA;
EXIST'G CPT OTHERWISE
GYP. BD. BLKHD, PAINT;
EXIST'G. ACT TO REMAIN
SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
4" VINYL @ RENOV. EXIST'G. CONSTR. @ GYP. BD/PLAST @ RENOV.
CLOS. WALLS, PAINT RENOV. CLOS., PAINTCLOSET/OFFICE EA
S T
W
IN
G
OFFICE330
GYP. BD/PLAST.,
PAINT
4" WOOD - MATCH
EXIST'G, PAINT EXIST'G. CPT TO REMAIN
RECONFIGURE 2'X2' ACT CEIL'G NEAR DOOR #334A TO MATCH EXIST'G.;
OFFICE331
PAINT ENTIRE EXIST'G. EAST & NORTH WALL AREAS
4" WOOD - MATCH
EXIST'G, PAINT
EXIST'G. CARPET TILES
TO REMAIN
EXIST'G. CARPET TILES
TO REMAIN
GYP. BOARD @ RENOV.
WALLS, PAINT
EXIST'G. ACT TO
REMAIN, PAINT SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
MEETING ROOM334
4" WOOD - MATCH
EXIST'G, PAINT
GYP. BOARD @ RENOV.
AREA, PAINT SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.GYP. BD. BLKHD, PAINT;
EXIST'G. ACT TO REMAIN
UTR
STORAGE
STORAGE
OFFICE
CORRIDOR339
EXIST'G. TO REMAIN @4" VINYL @ RENOV.
UTR
UTR
WORK AREA
UTR
EXIST'G. CONSTR. @
352 WORK AREA
4" WOOD - MATCH
EXIST'G, PAINT GYP. BD/PLAST., PAINTEXIST'G. CARPET TILES
TO REMAIN
EXIST'G. 2'X2' ACT
TO REMAIN SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
6" H.T., COVED HT-1
6" H.T., COVED HT-1 2'X2' ACT-1/GYP. BD.
BLKHD, PAINT
GYP. BD. BLKHD,
PAINT
4" WOOD - MATCH
EXIST'G, PAINT GYP. BD/PLAST., PAINT
6" H.T., COVED HT-1
6" H.T., COVED HT-1 2'X2' ACT-1
2'X2' ACT-1
2'X2' ACT-1
GYP. BD. BLKHD,
PAINT
4" WOOD - MATCH
EXIST'G, PAINT GYP. BD/PLAST., PAINT
GYP. BD/PLAST @ RENOV.
CLOS. WALLS, PAINT RENOV. CLOS., PAINTCLOSET RENOV. CLOSET SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
N O
R
TH
W
IN
G
OFFICE322
EXIST'G. TO REMAIN @4" VINYL @ RENOV. EXIST'G. CONSTR. @ GYP. BD/PLAST @ RENOV.
CLOS. WALLS, PAINT RENOV. CLOS., PAINTCLOSET RENOV. CLOSET SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
CORRIDOR338
4" WOOD - MATCH
EXIST'G, PAINT GYP. BD/PLAST., PAINTEXIST'G. CARPET TILES
TO REMAIN
EXIST'G. 2'X2' ACT
TO REMAIN SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
S O
U
TH
W
IN
G
LOBBY400
4" WOOD @ WORK
AREA-MATCH EXIST'G.
EXIST'G. CARPET
TO REMAIN
REALIGN EXIST'G. ACT
@ WORK AREA
GYP. BD. @ WORK AREA,
PAINT - MATCH EXIST'G.
EA
S T
UTR
STORAGE
STORAGE
OFFICE
CORRIDOR439
EXIST'G. TO REMAIN @4" VINYL @ RENOV.
UTR
UTR
WORK AREA
UTR
EXIST'G. CONSTR. @
452 WORK AREA
4" WOOD - MATCH
EXIST'G, PAINT GYP. BD/PLAST., PAINTEXIST'G. CARPET TILES
TO REMAIN
EXIST'G. 2'X2' ACT
TO REMAIN SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
6" H.T., COVED HT-1
6" H.T., COVED HT-1 2'X2' ACT-1/GYP. BD.
BLKHD, PAINT
GYP. BD. BLKHD,
PAINT
4" WOOD - MATCH
EXIST'G, PAINT GYP. BD/PLAST., PAINT
6" H.T., COVED HT-1
6" H.T., COVED HT-1 2'X2' ACT-1
2'X2' ACT-1
2'X2' ACT-1
GYP. BD. BLKHD,
PAINT
4" WOOD - MATCH
EXIST'G, PAINT GYP. BD/PLAST., PAINT
GYP. BD/PLAST @ RENOV.
CLOS. WALLS, PAINT RENOV. CLOS., PAINTCLOSET RENOV. CLOSET SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
N O
R
TH
W
IN
G
MEETING422
EXIST'G. TO REMAIN @4" VINYL @ RENOV. EXIST'G. CONSTR. @ GYP. BD/PLAST @ RENOV.
CLOS. WALLS, PAINT RENOV. CLOS., PAINTCLOSET RENOV. CLOSET SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
CORRIDOR438
4" WOOD - MATCH
EXIST'G, PAINT GYP. BD/PLAST., PAINTEXIST'G. CARPET TILES
TO REMAIN
EXIST'G. 2'X2' ACT
TO REMAIN SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
S O
U
TH
W
IN
G
SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.
- 1 -
- - SMOKE
SMOKE
SMOKE
HMHM -- 5- - SMOKE
SMOKE
SMOKE-
SMOKE
SMOKE
B HMHM
B - HMHM
- HMWD -
A - 1 HMWD -
B - HMHM -
B
A - 1 HMWD -
A - 1 HMWD
3'-0" x 7'-0" x 1 3/4"
3'-0" x 7'-0" x 1 3/4"
18" x 32"
24" x 24"
3'-0" x 6'-8" x 1 3/4"
3'-0" x 7'-0" x 1 3/4"
A
245A
251A
243A UTR #243
UTR #245
251B
242A
252A
240A UTR #240
UTR #242
252B
18" x 32"
24" x 24"
- - SMOKE
SMOKE
SMOKE
HMHM -- 5- - SMOKE
SMOKE
SMOKE-
SMOKE
SMOKE
B
HMHM
B - HMHM
- HMWD -
A - 1 HMWD -
B - HMHM -
B
A - 1 HMWD - -
A - 1 HMWD -
3'-0" x 7'-0" x 1 3/4"
3'-0" x 7'-0" x 1 3/4"
18" x 32"
24" x 24"
3'-0" x 6'-8" x 1 3/4"
3'-0" x 7'-0" x 1 3/4"
A
345A
351A
343A UTR #343
UTR #345
351B
342A
352A
340A UTR #340
UTR #342
352B
18" x 32"
24" x 24"
- - SMOKE
SMOKE
SMOKE
HMHM -- 5- - SMOKE
SMOKE
SMOKE-
SMOKE
SMOKE
A -3'-0" x 6'-8" x 1 3/4" 1 HMWD - 4348A STORAGE #348
- HMWD - -3'-0" x 6'-8" x 1 3/4" A 21 SMOKE
B HMHM
B - HMHM
- HMWD -
A - 1 HMWD -
B - HMHM -
B
A - 1 HMWD - -
A - 1 HMWD -
3'-0" x 7'-0" x 1 3/4"
3'-0" x 7'-0" x 1 3/4"
18" x 32"
24" x 24"
3'-0" x 6'-8" x 1 3/4"
3'-0" x 7'-0" x 1 3/4"
A
445A
451A
443A UTR #443
UTR #445
451B
442A
452A
440A UTR #440
UTR#442
452B
18" x 32"
24" x 24"
- - SMOKE
SMOKE
SMOKE
HMHM -- 5- - SMOKE
SMOKE
SMOKE-
SMOKE
SMOKE
4/A101 3/A101
CPT-1
CPT-1
CPT-1
CPT-1
CPT-1
CPT-1
WORK AREA #151
WORK AREA #152
WORK AREA #152
WORK AREA #251
WORK AREA #251
WORK AREA #252
WORK AREA #252
WORK AREA #351
WORK AREA #351
WORK AREA #352
WORK AREA #352
WORK AREA #451
WORK AREA #451
WORK AREA #452
WORK AREA #452
GYP. BOARD, PAINT
GYP. BOARD, PAINT SOLID SURF. WINDOW SILL
GYP. BOARD, PAINTCPT-1 @ RENOV. AREA;
EXIST'G CPT OTHERWISE
EXIST'G. EXIST'G. SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.EXIST'G. TO REMAIN-
CONC. PATCH @ DEMO.
EXIST'G. TO REMAIN-
PATCH @ DEMO AREA
GYP. BOARD, PAINT
GYP. BOARD, PAINT
SOLID SURF. WINDOW SILL
SOLID SURF. WINDOW SILL
EXIST'G. EXIST'G. SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.EXIST'G. TO REMAIN-
CONC. PATCH @ DEMO.
EXIST'G. TO REMAIN-
PATCH @ DEMO AREA
EXIST'G. EXIST'G. SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.EXIST'G. TO REMAIN-
CONC. PATCH @ DEMO.
EXIST'G. TO REMAIN-
PATCH @ DEMO AREA
GYP. BOARD, PAINT
GYP. BOARD, PAINT
GYP. BOARD, PAINT
GYP. BOARD, PAINT
SOLID SURF. WINDOW SILL
SOLID SURF. WINDOW SILL
SOLID SURF. WINDOW SILL
SOLID SURF. WINDOW SILL
CPT-1 @ RENOV. AREA;
EXIST'G CPT OTHERWISE GYP. BOARD, PAINT
SOLID SURF. WINDOW SILL
SOLID SURF. WINDOW SILL
GYP. BOARD, PAINT
GYP. BOARD, PAINT
GYP. BOARD, PAINT
GYP. BOARD, PAINT
GYP. BOARD, PAINT
GYP. BOARD, PAINT
GYP. BOARD, PAINT
GYP. BOARD, PAINT
GYP. BOARD, PAINT
GYP. BOARD, PAINT
SOLID SURF. WINDOW SILL
SOLID SURF. WINDOW SILL
SOLID SURF. WINDOW SILL
SOLID SURF. WINDOW SILL
SOLID SURF. WINDOW SILL
SOLID SURF. WINDOW SILL
SOLID SURF. WINDOW SILL
SOLID SURF. WINDOW SILL
CPT-1
CPT-1
EXIST'G. EXIST'G. EXIST'G.EXIST'G.
GYP. BOARD, PAINT
EXIST'G. EXIST'G. SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.EXIST'G. TO REMAIN-
CONC. PATCH @ DEMO.
EXIST'G. TO REMAIN-
PATCH @ DEMO AREA
CPT-1
EXIST'G. EXIST'G. SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.EXIST'G. TO REMAIN-
CONC. PATCH @ DEMO.
EXIST'G. TO REMAIN-
PATCH @ DEMO AREA
EXIST'G. EXIST'G. SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.EXIST'G. TO REMAIN-
CONC. PATCH @ DEMO.
EXIST'G. TO REMAIN-
PATCH @ DEMO AREA
EXIST'G. EXIST'G. SCOPE IS LIMITED TO WORK AREA ONLY; PATCH/REPAIR TO MATCH EXIST'G.EXIST'G. TO REMAIN-
CONC. PATCH @ DEMO.
EXIST'G. TO REMAIN-
PATCH @ DEMO AREA
EXIST'G. TO REMAIN,
REWORK AS REQ'D.
PAINT ENTIRE EXIST'G. OFFICE NORTH WALL
PAINT ENTIRE EXIST'G. OFFICE NORTH WALL
EXIST'G. EXIST'G. EXIST'G. EXIST'G.
EXIST'G. EXIST'G. EXIST'G. EXIST'G.
EXIST'G. EXIST'G. EXIST'G. EXIST'G.
SCALE: 3" = 1'-0"
JAMB3
A101 SCALE: 3" = 1'-0"
HEAD4
A101
2/A101 1/A101
2/A101 1/A101
2/A101 1/A101
2/A101 1/A101
2/A101 1/A101
2/A101 1/A101
4/A101 3/A101
2/A101 1/A101
2/A101 1/A101
2/A101 1/A101
2/A101 1/A101
2/A101 1/A101
2/A101 1/A101
2/A101 1/A101
2/A101 1/A101
2/A101 1/A101
2/A101 1/A101
2/A101 1/A101
2/A101 1/A101
2/A101 1/A101
4/A101 3/A101
4/A101 3/A101
4/A101 3/A101
4/A101 3/A101
4/A101 3/A101
4/A101 3/A101
2/A101 1/A101
SCALE: 3" = 1'-0"
JAMB5
A101 SCALE: 3" = 1'-0"
HEAD6
A101
6/A101 5/A101
6/A101 5/A101
6/A101 5/A101
6/A101 5/A101
6/A101 5/A101
6/A101 5/A101
6/A101 5/A101
6/A101 5/A101
1 2 3 4 5 6
7 8 9 10 11
12 13 14 15 16 17
D
E
F
G
C
B
A
EX
T'
G F
.P
EXT'G FIRE
PROTECTION
RISER UP
FROM OUT
OF TUNNEL
EXT'G FIRE PROTECTION LINE
FROM MECH/BOILER ROOM.
LOCATED ROUGHLY 60 FT
SOUTH (VERIFY IN FIELD).
1 2 3 4 5 6
7 8 9 10 11
12 13 14 15 16 17
D
E
F
G
C
B
A
BUILDING SUMMARY
AREA*
OCCUPANCY HAZARDS**
TOTAL AREA 3,543 SQ FT
* VERIFY ALL AREAS WITH FINAL ARCHITECTURAL DRAWINGS
** CONFIRM HAZARD CLASSIFICATIONS WITH NFPA 13
EXT'G FP
RISER
EXT'G FP
RISER
TOTAL AREA W/ ALT #1 & #2 3,827 SQ FT
SCOPE OF FIRE PROTECTION RE-WORK
ALTERNATE #1
SCOPE OF FIRE PROTECTION RE-WORK
ALTERNATE #2
REWORK THE EXISTING FIRE PROTECTION SPRINKLER SYSTEM AS DEFINED BY THE INTERNATIONAL BUILDING CODE AND NFPA NO. 13. INSTALL NEW SPRINKLER HEADS AND BRANCH PIPING. EXISTING MAINS AND BRANCHES SHALL BE USED TO MEET SPRINKLER REQUIREMENTS. NEW PIPING SHALL BE COPPER TYPE L WITH WROUGHT FITTINGS OR SCHEDULE 40 BLACK IRON WITH C1 SCREWED FITTINGS. SPRINKLER HEADS SHALL BE NOMINAL 1/2" BRONZE FINISH UPRIGHT IN EXPOSED AREAS AND (CHROME PLATED OR WHITE POLYESTER COATED) WITH ESCUTCHEON IN FINISHED AREAS. FUSIBLE SOLDER LINK TYPE RATED FOR SPECIFIC AREA HAZARD. PROVIDE SPRINKLER WRENCH AND (2) SPARE HEADS IN CABINET MOUNTED
IN MECHANICAL ROOM.
FIRE PROTECTION NOTES
THE FIRE PROTECTION SYSTEM IS UNDER THE GENERAL CONTRACT AND ALL SYSTEMS, EQUIPMENT, PIPING, SITE WORK, WATER STORAGE TANK ETC. ARE TO BE PROVIDED UNDER THE CONTRACT FOR A
COMPLETE FUNCTIONAL SYSTEM THAT PASSES ALL CODES AND OFS INSPECTIONS.
FP200
DRAWING TITLE
KCT PROJECT NO.DRAWN
EHT
REVIEWED
DAR
DATE
SCALE
AS NOTED
DRAWING NO.
SEAL
SHEET NO.
NO. REVISIONS / SUBMISSIONS DATE
PROJECT NAME
FIRE PROTECTION
OVERALL TUNNEL &
C op yr ig ht
Ke nd ra C
. T ho m ps on A rc hi te ct s, P
.C
UPGRADE PROJECT FOR:
MICHIGAN
MI FILE NO. 171/21349.GAG
STATE OF
OFFICE BLDG.
701 S. ELMWOOD - TRAVERSE CITY, MI
BATHROOM & PLUMBING
1 DESIGN DEVELOPMENT SET 9/24/2025
2 CD 50% REVIEW SET 4/29/2026
3 CD 90% REVIEW SET 6/5/2026
4 BCC PLAN REVIEW SET 6/17/2026
5 BID SET 6/26/2026
6 ADDENDUM #1 7/22/2026
SCALE: 1/8" = 1'-0"
FIRE PROTECTION OVERALL TUNNEL LEVEL
N JUNE 2026
KT-216007C
SCALE: 1/8" = 1'-0"
FIRE PROTECTION OVERALL GROUND LEVEL
N
GROUND LEVELS
kendra c.
architects, p.c.
THOMPSON
803 Cherry Street Manistee, MI 49660 tel: 231.723.4195 www.kendrathompson-architects.com
12 13 14 15 16 17
D
E
F
G
C
B
A
EXT'G FP
RISER
EXT'G FP
RISER
SCOPE OF FIRE PROTECTION
RE-WORK (TYP.)
SCOPE OF FIRE PROTECTION
RE-WORK (TYP.)
SCOPE OF FIRE PROTECTION
RE-WORK (TYP.)
1 2 3 4 5 6
7 8 9 10 11
12 13 14 15 16 17
D
E
F
G
C
B
A
EXT'G FP
RISER
EXT'G FP
RISER
SCOPE OF FIRE PROTECTION
RE-WORK (TYP.)
SCOPE OF FIRE PROTECTION
RE-WORK (TYP.)
SCOPE OF FIRE PROTECTION
RE-WORK (TYP.)
FP201
DRAWING TITLE
KCT PROJECT NO.DRAWN
EHT
REVIEWED
DAR
DATE
SCALE
AS NOTED
DRAWING NO.
SEAL
SHEET NO.
NO. REVISIONS / SUBMISSIONS DATE
PROJECT NAME
C op yr ig ht
Ke nd ra C
. T ho m ps on A rc hi te ct s, P
.C
UPGRADE PROJECT FOR:
MICHIGAN
MI FILE NO. 171/21349.GAG
STATE OF
OFFICE BLDG.
701 S. ELMWOOD - TRAVERSE CITY, MI
BATHROOM & PLUMBING
1 DESIGN DEVELOPMENT SET 9/24/2025
2 CD 50% REVIEW SET 4/29/2026
3 CD 90% REVIEW SET 6/5/2026
4 BCC PLAN REVIEW SET 6/17/2026
5 BID SET 6/26/2026
6 ADDENDUM #1 7/22/2026
SCALE: 1/8" = 1'-0"
FIRE PROTECTION OVERALL FLOOR LEVEL - 1
N JUNE 2026
KT-216007C
SCALE: 1/8" = 1'-0"
FIRE PROTECTION OVERALL FLOOR LEVEL - 2
N
FIRE PROTECTION
OVERALL FLOOR
LEVELS 1 & 2
kendra c.
architects, p.c.
THOMPSON
803 Cherry Street Manistee, MI 49660 tel: 231.723.4195
12 13 14 15 16 17
D
E
F
G
C
B
A
EXT'G FP
RISER
EXT'G FP
RISER SCOPE OF FIRE PROTECTION
RE-WORK (TYP.)
SCOPE OF FIRE PROTECTION
RE-WORK (TYP.)
SCOPE OF FIRE PROTECTION
RE-WORK (TYP.)
1 2 3 4 5 6
7 8 9 10 11
12 13 14 15 16 17
D
E
F
G
C
B
A
EXT'G FP
RISER
EXT'G FP
RISER
SCOPE OF FIRE PROTECTION
RE-WORK (TYP.)
SCOPE OF FIRE PROTECTION
RE-WORK (TYP.)
FP202
DRAWING TITLE
KCT PROJECT NO.DRAWN
EHT
REVIEWED
DAR
DATE
SCALE
AS NOTED
DRAWING NO.
SEAL
SHEET NO.
NO. REVISIONS / SUBMISSIONS DATE
PROJECT NAME
C op yr ig ht
Ke nd ra C
. T ho m ps on A rc hi te ct s, P
.C
UPGRADE PROJECT FOR:
MICHIGAN
MI FILE NO. 171/21349.GAG
STATE OF
OFFICE BLDG.
701 S. ELMWOOD - TRAVERSE CITY, MI
BATHROOM & PLUMBING
1 DESIGN DEVELOPMENT SET 9/24/2025
2 CD 50% REVIEW SET 4/29/2026
3 CD 90% REVIEW SET 6/5/2026
4 BCC PLAN REVIEW SET 6/17/2026
5 BID SET 6/26/2026
6 ADDENDUM #1 7/22/2026
SCALE: 1/8" = 1'-0"
FIRE PROTECTION OVERALL FLOOR LEVEL - 3
N JUNE 2026
KT-216007C
SCALE: 1/8" = 1'-0"
FIRE PROTECTION OVERALL FLOOR LEVEL - 4
N
FIRE PROTECTION
OVERALL FLOOR
LEVELS 3 & 4
kendra c.
architects, p.c.
THOMPSON
803 Cherry Street Manistee, MI 49660 tel: 231.723.4195
SPECIAL NOTICE TO CONTRACTORS
1. IT IS REQUIRED THAT ALL CONTRACTORS BIDDING THIS PROJECT VISIT THE JOB SITE AND
VERIFY THE EXISTING CONDITIONS PRIOR TO SUBMITTING THEIR BID. CONTRACTORS ARE TO
CAREFULLY REVIEW ALL CONSTRUCTION DOCUMENTS AND NOTE ANY DISCREPANCIES
BETWEEN THE CONSTRUCTION DOCUMENTS AND THE CONDITIONS OBSERVED AT THE JOB
SITE PRIOR TO SUBMISSION OF ANY BID. THE BUILDING OWNER REPRESENTATIVE MAY BE
CONTACTED FOR ACCESS TO THE JOB SITE.
2. PRIOR TO CONSTRUCTION, CONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE LOCATION
AND CONDITION OF THE FOLLOWING:
A. ALL POINTS OF CONNECTION TO BUILDING UTILITIES AND/OR SYSTEMS INCLUDING, BUT
NOT LIMITED TO, GAS, WATER, SEWER, VENT, ELECTRICAL, MECHANICAL SYSTEMS,
DUCTWORK, EXHAUST/OUTSIDE AIR, SECURITY, FIRE/LIFE SAFETY, DATA, AND PHONE.
B. ALL REQUIRED CONNECTIONS TO THE BUILDING STRUCTURE.
C. ALL REQUIRED BUILDING PENETRATIONS.
3. ANY DISCREPANCIES BETWEEN THE CONSTRUCTION DOCUMENTS AND THE CONDITIONS
OBSERVED SHALL BE BROUGHT TO THE ATTENTION, IN WRITING, TO THE ARCHITECT AND/OR
ENGINEER PRIOR TO PROCEEDING WITH CONSTRUCTION.
4. REFER TO THE CONSTRUCTION DOCUMENTS FOR ALL CONTACT INFORMATION.
PLUMBING DEMOLITION NOTES
1. FIXTURE, PIPING, ETC., TAGGED WITH A PRECEDING "EXT'G" OR "x" ARE EXISTING.
2. BEFORE COMMENCING WORK ENSURE DOMESTIC SERVICES ARE OFF, AND ELECTRICAL
POWER IS TURNED OFF TO THE EXISTING EQUIPMENT.
3. THE PLUMBING CONTRACTOR SHALL REMOVE ALL ITEMS INDICATED AND SHALL BE
RESPONSIBLE FOR THEIR DISPOSAL PER LOCAL, STATE AND FEDERAL REGULATIONS AND
PAY FOR ALL ASSOCIATED COSTS OF DISPOSAL.
4. THE PLUMBING CONTRACTOR SHALL COORDINATE WITH THE OWNER'S REPRESENTATIVE TO
DETERMINE IF ANY PARTS OR FIXTURES ARE DESIRED TO BE KEPT BY THE OWNER. THE
OWNER SHALL HAVE THE RIGHT OF FIRST REFUSAL. ANY ITEM NOT WISHED TO BE RETAINED,
SHALL BE DISPOSED OF AT THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR.
5. ITEMS HATCHED SHALL BE PERMANENTLY REMOVED.
6. ITEMS CLOUDED SHALL BE TEMPORARILY REMOVED AND REUSED.
PLUMBING ABBREVIATIONS
AAV AIR ADMITTANCE VALVE
ADA AMERICAN DISABILITIES ACT
ADJ ADJUSTABLE
AF ABOVE ROUGH FLOOR
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
ASHRAE AMERICAN SOCIETY OF HEATING,
REFRIGERATION, AND AIR
CONDITIONING ENGINEERS
AV AIR VENT
ABV ABOVE
BFP BACKFLOW PREVENTER
BG BELOW GRADE
BV BALANCING VALVE
CB CATCH BASIN
CF CUBIC FEET
CI CAST IRON
CO CLEANOUT
COND CONDENSATE
CS CIRCUIT SETTER
CW DOMESTIC COLD WATER
DN DOWN
DS DOWNSPOUT
DWV DRAIN/WASTE/VENT
EC ELECTRICAL CONTRACTOR
ELEC ELECTRICAL
EQUIP EQUIPMENT
ET EXPANSION TANK
EWC ELECTRIC WATER COOLER
EX EXISTING (ALSO: "EXT'G", "x")
FCO FLOOR CLEAN OUT
FD FLOOR DRAIN
FS FLOOR SINK
FSEC FOOD SERVICE EQUIPMENT CONTRACTOR
FV or VIF FIELD VERIFY or VERIFY IN FIELD
G GAS, NATURAL GAS OR LP AS NOTED
GAL GALLONS
GC GENERAL CONTRACTOR
GD GARBAGE DISPOSAL
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GT GREASE TRAP
HB HOSE BIBB
HW DOMESTIC HOT WATER
IE INVERT ELEVATION
KW KILOWATT
LAV LAVATORY
LBS POUNDS
LP LIQUID PROPANE
MBH THOUSAND BTU PER HOUR
MC MECHANICAL CONTRACTOR
MBC MICHIGAN BUILDING CODE
MMC MICHIGAN MECHANICAL CODE
MS MOP SINK
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION. LIFE SAFETY CODE
NG NATURAL GAS
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NT NEUTRALIZATION TANK
OS OIL SEPARATOR
PRV PRESSURE REDUCING VALVE
RC RAIN CONDUCTOR
RD ROOF DRAIN
RI ROUGH-IN
RO ROUGH OPENING
RPZ REDUCED PRESSURE ZONE (BF
PREVENTER)
SAN SANITARY WASTE
SF SQUARE FEET
SK SINK
SPKR SPRINKLER
SS STAINLESS STEEL
ST STORM
TBD TO BE DETERMINED (DURING
CONSTRUCTION)
TD TRENCH DRAIN
TMV THERMOSTATIC MIXING VALVE
TO TOP OF...(DUCT, PIPE, ETC.)
T/P TEMPERATURE AND PRESSURE
TPV TRAP PRIMER VALVE
TYP TYPICAL
UR URINAL
UG UNDERGROUND
UL UNITED LABORATORIES TESTING
AGENCY
UW UNTREATED WATER
V VENT
VIF or FV VERIFY IN FIELD or FIELD VERIFY
VTR VENT THRU ROOF
WC WATER CLOSET
WCO WALL CLEAN OUT
WH WATER HEATER
PLUMBING SYMBOL LEGEND
CA
COND
DOMESTIC COLD WATER (CW) PIPING
DOMESTIC COLD WATER (CW) PIPING BELOW FLOOR
CW
DOMESTIC HOT WATER (HW) PIPING
M METER (GAS OR WATER)
GAS COCK
GAS SOLENOID VALVE
FLOW DIRECTION DESIGNATOR
DOMESTIC HOT WATER (HW) PIPING BELOW FLOOR
DOMESTIC TEMPERED WATER (TW) PIPING
DOMESTIC HOT WATER RECIRCULATED (HWR) PIPING
SANITARY WASTE/SEWER (SAN) PIPING
SANITARY WASTE/SEWER (SAN) PIPING BELOW FLOOR
STORM (ST) PIPING
STORM (ST) PIPING BELOW FLOOR
VENT (V) PIPING
CONDENSATE (COND) PIPING
GAS (G) PIPING
COMPRESSED AIR (CA) PIPING
PIPE DOWN
PIPE UP
PIPE BREAK (FOR CLARITY)
CAPPED PIPE
BALL VALVE, SHUT-OFF AND ISOLATION
UNION
STRAINER WITH BLOWDOWN
WALL CLEANOUT (WCO)
NEW-TO-EXISTING CONNECTION
CW
HW
HW
TW
HWR
G
SAN
SAN
ST
ST
VENT
CIRCUIT SETTER W/ TEST PORTS (CS)
STANDARD CHECK VALVE
BALANCING VALVE W/ SHUT-OFF ABILITY & TEST PORTS (BV)
PRESSURE REDUCING VALVE (PRV)
REDUCED PRESSURE ZONE ASSEMBLY (RPZ)
PUMP, PLAN VIEW
DOUBLE CHECK VALVE
P100
DRAWING TITLE
KCT PROJECT NO.DRAWN
EHT
REVIEWED
DAR
DATE
SCALE
AS NOTED
DRAWING NO.
SEAL
SHEET NO.
NO. REVISIONS / SUBMISSIONS DATE
PROJECT NAME
C op yr ig ht
Ke nd ra C
. T ho m ps on A rc hi te ct s, P
.C
UPGRADE PROJECT FOR:
MICHIGAN
MI FILE NO. 171/21349.GAG
STATE OF
OFFICE BLDG.
701 S. ELMWOOD - TRAVERSE CITY, MI
BATHROOM & PLUMBING
1 DESIGN DEVELOPMENT SET 9/24/2025
2 CD 50% REVIEW SET 4/29/2026
3 CD 90% REVIEW SET 6/5/2026
4 BCC PLAN REVIEW SET 6/17/2026
5 BID SET 6/26/2026
6 ADDENDUM #1 7/22/2026
JUNE 2026
KT-216007C
kendra c.
architects, p.c.
THOMPSON
803 Cherry Street Manistee, MI 49660 tel: 231.723.4195 thompson.kendra@sbcglobal.net www.kendrathompson-architects.com
PLUMBING
SYMBOL LEGEND &
ABBREVIATIONS
AutoCAD SHX Text G
12 13 14 15 16 17
D
E
F
G
C
B
A
TUNNEL
EXT'G 3" CW BACK TO
BOILER/MAINTENANCE BLDG
EXT'G HWS
EXT'G HWR
EXT'G F.P.
EXT'G
SAN
EXT'G CW UP
EXT'G CW, HW UP
TO REMAIN
EXT'G SAN RISER
EXT'G CW,
HW RISERS
EXT'G CW, HW MAINS
EXT'G SAN RISEREXT'G SAN RISER
EXT'G SAN RISEREXT'G CW UP
EXT'G
CW UP
EXT'G SAN TO
REMAIN
EXT'G
SAN
RISER
EXT'G STORM
EXT'G
SAN
EXT'G CW, HW UP
EXT'G CW, HW UP
EXT'G SAN RISER
EXT'G STORM
EXISTING STORM TO REMAIN.
CONTRACTOR TO VERIFY
STORM LINE IN FIELD (TYP).
EXT'G
C.O. (TYP.
OF 2)EXT'G SAN
EXT'G ST
EX
T'
G S
AN
EXT'G STORM DOWN
EXT'G
C.O. EXT'G SAN
EXT'G SAN
EXT'G ST
EXT'G
C.O.
EXT'G CW
EXT'G SAN
EXT'G CW
EXT'G SAN
EXT'G CW
EXT'G
C.O.
EX
T'
G C
W
EXT'G STORM RISER
EXT'G SAN RISER
EXT'G STORM RISER
EXT'G SAN RISER
EX
T'
G F
.P x8" SAN
MAIN BLDG
SEWER EXIT
DEMO EXT'G 8" SAN TO THIS
POINT (BUILDING OUTLET).
PREPARE TO TIE IN NEW
SAN TO EXT'G 8" SAN
EXISTING STORM TO REMAIN.
CONTRACTOR TO VERIFY
STORM LINE IN FIELD (TYP).
PD-1
EXISTING STORM TO REMAIN.
CONTRACTOR TO VERIFY
STORM LINE IN FIELD (TYP).
EXISTING STORM TO REMAIN.
CONTRACTOR TO VERIFY
STORM LINE IN FIELD (TYP).
EXT'G EWH
(TYP. OF 2)
EXT'G HHWS,
HHWR, & F.P.
RISERS TO
REMAIN
DEMO EXT'G 3" CW MAIN TO THIS
POINT. DEMO EXT'G SHUT-OFF VALVE
PD-1
PD-1
PD-1
PD-1
PD-1
PD-1
PD-1
PD-1
PD-1
PD-1
PD-1
1 2 3 4 5 6
7 8 9 10 11
12 13 14 15 16 17
D
E
F
G
C
B
A
18A
SHWR
U.T.R. U.T.R.
16 15
ELEV.
495028293031323334STAFF
WOMENS
MENS
39 38 37 36
43 1
MAINTENANCE SHOP
S-3
J.C.
STOR
STAIR #1
S-2 20
J.C.
CONFERENCE
xLAV xSH xWC xLAV's xSS xWC xWC''sxUR's xLAV's xS
EXT'G SAN RISER
EXT'G STORM RISER
EXT'G CW/HW RISER
EXT'G SAN RISER
EXT'G STORM RISER
EXT'G CW/HW RISER
xHB xHB xHB xHB xEWH xSS
ALTERNATE #1
SEE SHEET P200 AND P203
PD-3 PD-3
PD-3 PD-3
PD-3
THE CONTRACTOR SHALL VERIFY THE SANITARY, COLD WATER, AND HOT WATER
SERVICE LOCATIONS TO THESE BATHROOMS FROM THE TUNNEL BELOW.
BASE BID: TIE THE EXT'G FIXTURES TO THE NEW SANITARY, COLD WATER, AND
HOT WATER SERVICES IF ALT #2 IS NOT ACCEPTED. VERIFICATION IN FIELD IS
REQUIRED. IF ALT #2 IS ACCEPTED, NEW FIXTURES WILL BE REQUIRED, SEE
FIXTURE SCHEDULE FOR MORE INFORMATION.
ALTERNATE #2 SCOPE: DEMO AND
REMOVE ALL EXISTING FIXTURES, COLD
WATER, HOT WATER, VENTING, ETC.
PREPARE TO TIE NEW FIXTURES TO NEW
SERVICES. SEE SHEET P200 AND P203
FOR MORE INFORMATION
ALTERNATE #1 SCOPE: DEMO AND
REMOVE ALL EXISTING FIXTURES, COLD
WATER, HOT WATER, VENTING, ETC.
PREPARE TO TIE NEW FIXTURES TO NEW
SERVICES.
THE CONTRACTOR SHALL VERIFY THE SANITARY, COLD WATER, AND
HOT WATER SERVICE LOCATIONS TO THESE BATHROOMS FROM THE
TUNNEL BELOW.
BASE BID: TIE THE EXT'G FIXTURES TO THE NEW SANITARY, COLD
WATER, AND HOT WATER SERVICES IF ALT #2 IS NOT ACCEPTED.
VERIFICATION IN FIELD IS REQUIRED. IF ALT #2 IS ACCEPTED, NEW
FIXTURES WILL BE REQUIRED, SEE FIXTURE SCHEDULE FOR MORE
INFORMATION.
RE-LOCATE xWH CAREFULLY REMOVE AND
RE-LOCATE SINK TO NEW
COUNTER
CONTRACTOR SHALL INVESTIGATE
WHERE xHB IS FED FROM AS IT IS
NOT VISIBLE FROM TUNNEL BELOW.
(TYP. OF ALL HOSE BIBS)
PD-4
PD-4 CONTRACTOR SHALL INVESTIGATE
WHERE xHB IS FED FROM AS IT IS
NOT VISIBLE FROM TUNNEL BELOW.
(TYP. OF ALL HOSE BIBS)
PD-4
PD-4
THE CONTRACTOR SHALL INVESTIGATE THE EXT'G CW,
HW, SAN, & VENT LOCATION. DEMO THE EXISTING CW,
HW, SAN, VENTING. PREPARE TO TIE NEW 1" CW/HW
FROM BELOW TO THE xEWC AND TO THE xSS ON THIS
FLOOR. TIE NEW 3" SAN TO xSS FROM TUNNEL BELOW
TUNNEL SPACE:
1. DEMO AND REMOVE THE FOLLOWING:
1.1. EXT'G SANITARY LINES BACK TO THE EXT'G MAIN BUILDING SEWER OUTLET.
1.2. EXT'G VENTING LINES THROUGHOUT THE ENTIRE TUNNEL SPACE.
1.3. EXT'G COLD WATER LINES BACK TO THE EXISTING SHUT-OFF VALVE AS SHOWN ON
THE DRAWING. DEMO THE EXISTING SHUT-OFF VALVE AND PREPARE TO INSTALL
NEW 3" BALL VALVE.
1.4. EXT'G HOT WATER LINE BACK TO THE EXISTING WATER HEATERS. DEMO AND
REMOVE EXT'G WATER HEATERS.
2. EXISTING ITEMS THAT SHALL REMAIN: EXISTING STORM; EXISTING FIRE PROTECTION.
BATHROOM GROUPS & JANITOR CLOSET:
DEMO AND REMOVE EXISTING PLUMBING FIXTURES ALONG WITH ASSOCIATED HOT WATER,
COLD WATER LINES, VENTING, WALL SUPPORTS, ETC. SANITARY SHALL BE DEMO'D AND
CAPPED SO AS TO REMAIN FLUSH WITH FINISHED FLOOR.
CHASES:
1. DEMO AND REMOVE THE FOLLOWING EXISTING RISERS FROM TOP MOST FLOOR TO
TUNNEL SPACE BELOW: SANITARY, COLD WATER, HOT WATER, AND VENTING.
2. EXISTING STORM SHALL REMAIN; OTHER EXISTING RISERS NOT MENTIONED HERE BUT
FOUND IN CHASE TO REMAIN. CONTRACTOR SHALL VERIFY WITH THE ENGINEER IF ANY
QUESTIONS OR CONCERNS ARE FOUND BEFORE DEMOLITION WORK STARTS.
HOSE BIBS:
1. DEMO AND REMOVE ALL EXISTING COLD WATER PIPING LEADING FROM THE EXISTING
HOSE BIB BACK. INVESTIGATIVE DEMO WILL HAVE TO OCCUR; THE CONTRACTOR WILL
HAVE TO VERIFY IN FIELD WHERE THE COLD WATER LINE IS COMING FROM (TYP. FOR
ALL HOSE BIBS). DEMO TO THIS POINT SHOWN ON PLANS AND PREPARE TO TIE IN NEW
3/4" CW HERE (TYP. FOR ALL HOSE BIBS)
PD-1
PD-2
PD-3
PD-4
PLMG DEMOLITION KEYED NOTES PD-#
THE CONTRACTOR SHALL VERIFY ALL EXISTING SERVICES: SANITARY LINES, COLD/HOT WATER LINES, STORM LINES, AND VENTING PRIOR TO COMMENCING DEMOLITION WORK. THIS INCLUDES VERIFYING IN THE EXISTING TUNNEL, CEILING, AND CHASE SPACES. ANY QUESTIONS OR CONCERNS
REGARDING CONSTRUCTABILITY OF WORK SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT, OWNER, AND/OR ENGINEER (IN WRITING) BEFORE BIDDING THE PROJECT.
PD200
DRAWING TITLE
KCT PROJECT NO.DRAWN
EHT
REVIEWED
DAR
DATE
SCALE
AS NOTED
DRAWING NO.
SEAL
SHEET NO.
NO. REVISIONS / SUBMISSIONS DATE
PROJECT NAME
PLUMBING DEMO
OVERALL TUNNEL &
C op yr ig ht
Ke nd ra C
. T ho m ps on A rc hi te ct s, P
.C
UPGRADE PROJECT FOR:
MICHIGAN
MI FILE NO. 171/21349.GAG
STATE OF
OFFICE BLDG.
701 S. ELMWOOD - TRAVERSE CITY, MI
BATHROOM & PLUMBING
1 DESIGN DEVELOPMENT SET 9/24/2025
2 CD 50% REVIEW SET 4/29/2026
3 CD 90% REVIEW SET 6/5/2026
4 BCC PLAN REVIEW SET 6/17/2026
5 BID SET 6/26/2026
6 ADDENDUM #1 7/22/2026
SCALE: 1/8" = 1'-0"
PLUMBING DEMOLITION OVERALL TUNNEL LEVEL
N JUNE 2026
KT-216007C
SCALE: 1/8" = 1'-0"
PLUMBING DEMOLITION OVERALL GROUND LEVEL
N
GROUND LEVELS
kendra c.
architects, p.c.
THOMPSON
803 Cherry Street Manistee, MI 49660 tel: 231.723.4195
12 13 14 15 16 17
D
E
F
G
C
B
A
STOR.121
119 115
J.C.
127125
111 109
107 105 103 101
129 137
100B
STAFF
U.T.R.
100A
J.C.
I.T.
STO.
133 135 134
MENS
116104
136 128
106 108
126 124
U.T.R.
MEETING
WOM. COPY
UNISEX
STOR.
STO.STO.
ELEV.
xLAV xWC xWC xLAV xUR xSS xSS xWC xLAV xSS
PD-3
PD-3
PD-3
PD-3
PD-3
PD-2
PD-2
1 2 3 4 5 6
7 8 9 10 11
12 13 14 15 16 17
D
E
F
G
C
B
A
TRAVERSE CITY
217219
J.C.
209211
225 227
I.T.
229 237
ELEV.
U.T.R.
OFFICE
200A
J.C. STO.
235 234
228236
206 208
226 224
STAFF
U.T.R.
210 212
214 216
JC
220STAFFOFFICE WOMENS STOR. OFFICE
MENS
STO.STO.
xWC xLAV xSS xWC xLAV xUR xSS xSS DEMO EXT'G DOMESTIC SERVICES (CW, HW, DAN, VENT'G). PREPARE TO TIE NEW DOMESTIC
SERVICES TO EXT'G FIXTURE
PD-3
PD-3
PD-3
PD-3
PD-2
PD-2
PD-2
PD-3
TUNNEL SPACE:
1. DEMO AND REMOVE THE FOLLOWING:
1.1. EXT'G SANITARY LINES BACK TO THE EXT'G MAIN BUILDING SEWER OUTLET.
1.2. EXT'G VENTING LINES THROUGHOUT THE ENTIRE TUNNEL SPACE.
1.3. EXT'G COLD WATER LINES BACK TO THE EXISTING SHUT-OFF VALVE AS SHOWN ON
THE DRAWING. DEMO THE EXISTING SHUT-OFF VALVE AND PREPARE TO INSTALL
NEW 3" BALL VALVE.
1.4. EXT'G HOT WATER LINE BACK TO THE EXISTING WATER HEATERS. DEMO AND
REMOVE EXT'G WATER HEATERS.
2. EXISTING ITEMS THAT SHALL REMAIN: EXISTING STORM; EXISTING FIRE PROTECTION.
BATHROOM GROUPS & JANITOR CLOSET:
DEMO AND REMOVE EXISTING PLUMBING FIXTURES ALONG WITH ASSOCIATED HOT WATER,
COLD WATER LINES, VENTING, WALL SUPPORTS, ETC. SANITARY SHALL BE DEMO'D AND
CAPPED SO AS TO REMAIN FLUSH WITH FINISHED FLOOR.
CHASES:
1. DEMO AND REMOVE THE FOLLOWING EXISTING RISERS FROM TOP MOST FLOOR TO
TUNNEL SPACE BELOW: SANITARY, COLD WATER, HOT WATER, AND VENTING.
2. EXISTING STORM SHALL REMAIN; OTHER EXISTING RISERS NOT MENTIONED HERE BUT
FOUND IN CHASE TO REMAIN. CONTRACTOR SHALL VERIFY WITH THE ENGINEER IF ANY
QUESTIONS OR CONCERNS ARE FOUND BEFORE DEMOLITION WORK STARTS.
HOSE BIBS:
1. DEMO AND REMOVE ALL EXISTING COLD WATER PIPING LEADING FROM THE EXISTING
HOSE BIB BACK. INVESTIGATIVE DEMO WILL HAVE TO OCCUR; THE CONTRACTOR WILL
HAVE TO VERIFY IN FIELD WHERE THE COLD WATER LINE IS COMING FROM (TYP. FOR
ALL HOSE BIBS). DEMO TO THIS POINT SHOWN ON PLANS AND PREPARE TO TIE IN NEW
3/4" CW HERE (TYP. FOR ALL HOSE BIBS)
PD-1
PD-2
PD-3
PD-4
PLMG DEMOLITION KEYED NOTES PD-#
THE CONTRACTOR SHALL VERIFY ALL EXISTING SERVICES: SANITARY LINES, COLD/HOT WATER LINES, STORM LINES, AND VENTING PRIOR TO COMMENCING DEMOLITION WORK. THIS INCLUDES VERIFYING IN THE EXISTING TUNNEL, CEILING, AND CHASE SPACES. ANY QUESTIONS OR CONCERNS
REGARDING CONSTRUCTABILITY OF WORK SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT, OWNER, AND/OR ENGINEER (IN WRITING) BEFORE BIDDING THE PROJECT.
PD201
DRAWING TITLE
KCT PROJECT NO.DRAWN
EHT
REVIEWED
DAR
DATE
SCALE
AS NOTED
DRAWING NO.
SEAL
SHEET NO.
NO. REVISIONS / SUBMISSIONS DATE
PROJECT NAME
C op yr ig ht
Ke nd ra C
. T ho m ps on A rc hi te ct s, P
.C
UPGRADE PROJECT FOR:
MICHIGAN
MI FILE NO. 171/21349.GAG
STATE OF
OFFICE BLDG.
701 S. ELMWOOD - TRAVERSE CITY, MI
BATHROOM & PLUMBING
1 DESIGN DEVELOPMENT SET 9/24/2025
2 CD 50% REVIEW SET 4/29/2026
3 CD 90% REVIEW SET 6/5/2026
4 BCC PLAN REVIEW SET 6/17/2026
5 BID SET 6/26/2026
6 ADDENDUM #1 7/22/2026
SCALE: 1/8" = 1'-0"
PLUMBING DEMOLITION OVERALL FLOOR LEVEL - 1
N JUNE 2026
KT-216007C
SCALE: 1/8" = 1'-0"
PLUMBING DEMOLITION OVERALL FLOOR LEVEL - 2
N
PLUMBING DEMO
OVERALL FLOOR
LEVELS 1 & 2
kendra c.
architects, p.c.
THOMPSON
803 Cherry Street Manistee, MI 49660 tel: 231.723.4195
12 13 14 15 16 17
D
E
F
G
C
B
A
321 OFFICE
317319 315
WOMENS STOR. 323
311 309 307
305 303
STAFF
333 MTG. ROOM 332
OFFICE
300A
300 304
336 328 326
306 308 310
322324 OFFICE
314312 316
318301 302
U.T.R. U.T.R.
STO.
I.T.
J.C.
COPY MENS
ELEV.
xWC xLAV xSS xWC xLAV xUR xSS xSS DEMO xEWC AND
ASSOCIATED PIPING
BACK TO RISER
DEMO EXT'G PLMG FIXT'S
PD-3
PD-3
PD-3
PD-3
PD-3
PD-2
PD-2
EXT'G CW, HW, SAN, VENTING TO
BE DEMO'D AND REPLACED FOR
xSS. TIE NEW CW, HW, SAN, AND
VENTING SERVICES TO xSS.
1 2 3 4 5 6
7 8 9 10 11
12 13 14 15 16 17
D
E
F
G
C
B
A
419 415417
J.C.
MENS
405407409
MTG. RM. 427
402400401403
437429 400A
410408406404
426428 424
414412 416
COPY
MTG. RM. MENS
J.C.
U.T.R.
WOMENSCOPY
ELEV.
xWC's xLAV xSS xWC xLAV xSS xLAV xWC xLAV xWC
DEMO xEWC AND
PREPARE TO INSTALL
NEW EWC
PD-3
PD-3
PD-3
PD-3
PD-2
PD-2
PD-2
TUNNEL SPACE:
1. DEMO AND REMOVE THE FOLLOWING:
1.1. EXT'G SANITARY LINES BACK TO THE EXT'G MAIN BUILDING SEWER OUTLET.
1.2. EXT'G VENTING LINES THROUGHOUT THE ENTIRE TUNNEL SPACE.
1.3. EXT'G COLD WATER LINES BACK TO THE EXISTING SHUT-OFF VALVE AS SHOWN ON
THE DRAWING. DEMO THE EXISTING SHUT-OFF VALVE AND PREPARE TO INSTALL
NEW 3" BALL VALVE.
1.4. EXT'G HOT WATER LINE BACK TO THE EXISTING WATER HEATERS. DEMO AND
REMOVE EXT'G WATER HEATERS.
2. EXISTING ITEMS THAT SHALL REMAIN: EXISTING STORM; EXISTING FIRE PROTECTION.
BATHROOM GROUPS & JANITOR CLOSET:
DEMO AND REMOVE EXISTING PLUMBING FIXTURES ALONG WITH ASSOCIATED HOT WATER,
COLD WATER LINES, VENTING, WALL SUPPORTS, ETC. SANITARY SHALL BE DEMO'D AND
CAPPED SO AS TO REMAIN FLUSH WITH FINISHED FLOOR.
CHASES:
1. DEMO AND REMOVE THE FOLLOWING EXISTING RISERS FROM TOP MOST FLOOR TO
TUNNEL SPACE BELOW: SANITARY, COLD WATER, HOT WATER, AND VENTING.
2. EXISTING STORM SHALL REMAIN; OTHER EXISTING RISERS NOT MENTIONED HERE BUT
FOUND IN CHASE TO REMAIN. CONTRACTOR SHALL VERIFY WITH THE ENGINEER IF ANY
QUESTIONS OR CONCERNS ARE FOUND BEFORE DEMOLITION WORK STARTS.
HOSE BIBS:
1. DEMO AND REMOVE ALL EXISTING COLD WATER PIPING LEADING FROM THE EXISTING
HOSE BIB BACK. INVESTIGATIVE DEMO WILL HAVE TO OCCUR; THE CONTRACTOR WILL
HAVE TO VERIFY IN FIELD WHERE THE COLD WATER LINE IS COMING FROM (TYP. FOR
ALL HOSE BIBS). DEMO TO THIS POINT SHOWN ON PLANS AND PREPARE TO TIE IN NEW
3/4" CW HERE (TYP. FOR ALL HOSE BIBS)
PD-1
PD-2
PD-3
PD-4
PLMG DEMOLITION KEYED NOTES PD-#
THE CONTRACTOR SHALL VERIFY ALL EXISTING SERVICES: SANITARY LINES, COLD/HOT WATER LINES, STORM LINES, AND VENTING PRIOR TO COMMENCING DEMOLITION WORK. THIS INCLUDES VERIFYING IN THE EXISTING TUNNEL, CEILING, AND CHASE SPACES. ANY QUESTIONS OR CONCERNS
REGARDING CONSTRUCTABILITY OF WORK SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT, OWNER, AND/OR ENGINEER (IN WRITING) BEFORE BIDDING THE PROJECT.
PD202
DRAWING TITLE
KCT PROJECT NO.DRAWN
EHT
REVIEWED
DAR
DATE
SCALE
AS NOTED
DRAWING NO.
SEAL
SHEET NO.
NO. REVISIONS / SUBMISSIONS DATE
PROJECT NAME
C op yr ig ht
Ke nd ra C
. T ho m ps on A rc hi te ct s, P
.C
UPGRADE PROJECT FOR:
MICHIGAN
MI FILE NO. 171/21349.GAG
STATE OF
OFFICE BLDG.
701 S. ELMWOOD - TRAVERSE CITY, MI
BATHROOM & PLUMBING
1 DESIGN DEVELOPMENT SET 9/24/2025
2 CD 50% REVIEW SET 4/29/2026
3 CD 90% REVIEW SET 6/5/2026
4 BCC PLAN REVIEW SET 6/17/2026
5 BID SET 6/26/2026
6 ADDENDUM #1 7/22/2026
SCALE: 1/8" = 1'-0"
PLUMBING DEMOLITION OVERALL FLOOR LEVEL - 3
N JUNE 2026
KT-216007C
SCALE: 1/8" = 1'-0"
PLUMBING DEMOLITION OVERALL FLOOR LEVEL - 4
N
PLUMBING DEMO
OVERALL FLOOR
LEVELS 3 & 4
kendra c.
architects, p.c.
THOMPSON
803 Cherry Street Manistee, MI 49660 tel: 231.723.4195
12 13 14 15 16 17
D
E
F
G
C
B
A
EXT'G
SAN
EXT'G
SAN
EXT'G
SAN
EXT'G HWS
EXT'G HWR
EXT'G F.P.
EX
T'
G F
.P
TUNNEL
ELEV.
EWH-1
EWH-2
EX
T'
G
" C W
3" CW3" CW
2" C
W
3" SAN
4" S
AN
1- 1/
2" C
W
3/4" HWR3/4" HWR
C.O.
W
W
C.O.
C.O.
C.O.
W
S
S
S 2
S
EXT'G CW, HW UP
TO REMAIN
1- 1/
2" C
W
1-1/2" CW 1-1/2" CW
2" CW 2" CW
4" SAN 4" SAN
1- 1/
4" H
W
4" SAN4" SAN
4" S
AN
4" SAN
C.O.
C.O. 4" SAN 4" SAN 4" SAN6" SAN
4" S
AN
4"
S
AN
2" C
W
2" C
W
2" CW2" CW 2" CW
1-1/4" HW1-1/4" HW
2" H
W
3" CW2" CW
RP-1
2" HW2" HW
3/ 4"
H W
R
3/4" HWR 3/4" HWR
1-1/4" HW
1- 1/
4" H
W 3/
4" H
W R
2" H
W
1-1/4" HW
3/ 4"
H W
R
3/4" HWR 3/4" HWR
1-1/4" HW1-1/4" HW
6" SAN
8" WYE WHERE ALL
SANITARY LINES
MEET. TIE NEW 8"
SAN TO EXT'G 8" SAN
TIE NEW 3" CW TO NEW 3"
SHUT-OFF VALVE. TIE TO
EXT'G 3" CW LINE IN TUNNEL
EXT'G HWS,
HWR, & F.P.
RISERS TO
REMAIN
2" CW UP
1-1/4" HW UP
3/4" HWR DOWN
1-1/2" CW UP
1-1/4" HW UP
3/4" HWR
4" SAN RISER
3" V UP
3" SAN UP TO FD
(V.I.F.)
EXT'G ST DOWN BELOW
GRADE (V.I.F.) TO REMAIN
4" SAN RISER
3" V UP
1-1/2" CW UP
1-1/4" HW UP
3/4" HWR
2" CW UP
1-1/4" HW UP
3/4" HWR DOWN
3" V UP
4" SAN FROM ABOVE
3" VENT UP4" SAN FROM ABOVE
3" VENT UP
1" CW UP
1" HW UP
3/4" HWR
3" SAN RISER
3" V UP
TIE EXT'G SAN
TO NEW SAN TIE EXT'G
CW, HW TO
NEW MAINS
TIE NEW SAN
TO EXT'G SAN
(VERIFY SIZE
IN FIELD)
TIE NEW
CW/HW TO
UPPER
FIXTURES IF
ALT #1 IS
NOT
APPROVED
TIE NEW SAN
TO EXT'G SAN
(VERIFY SIZE
IN FIELD)
TIE NEW 4" SAN TO EXT'G
SAN (VERIFY SIZE IN FIELD)
THE CONTRACTOR SHALL VERIFY THE
SANITARY, COLD WATER, AND HOT
WATER SERVICES TO THE GROUND
FLOOR IN THIS AREA. TIE THE EXT'G
FIXTURES TO THE NEW SANITARY, COLD
WATER, AND HOT WATER SERVICES.
VERIFICATION IN FIELD IS REQUIRED.
1" CW
1" HW
3/4" HWR
2-1/2" CW
2-1/2" HW
TO WH'S
W
W
1 2 3 4 5 6
7 8 9 10 11
12 13 14 15 16 17
D
E
F
G
C
B
A
WC-1
S-1LAV-1
WC-1
LAV-1
SH-1
18A
U.T.R. U.T.R.
16 15
495028293031323334
37 36
43 1
MECHANICAL ROOM
MAINTENANCE SHOP
S-3
J.C.
TELE
STOR
STOR STOR
STAIR #1
S-2 20
J.C.
CONFERENCE
ELEV.
EXIST'G.EXIST'G.SHWR.
EXIST'G.
STOR.
NEW
U.T.R.
STAFF
RENOV'D
EXIST'G.
NEW
NEW
EXT'G STORM RISER
TO REMAIN TYP.
(VERIFY IN FIELD)
W
W
W
S1
S
S
S
S
EXT'G ST RISER TO REMAIN
4" SAN DOWN
4" SAN DOWN
EXT'G ST RISER TO REMAIN
CW, HW, SAN FED
FROM BELOW
(TYP. OF ALT #2)
HWR & HW DOWN
TO EWH'S
1-1/2" CW UP
1-1/4" HW UP
3/4" HWR UP
4" SAN RISER
3" V UP
2" CW UP
1-1/4" HW UP
3/4" HWR DOWN
3" V UP
2" CW UP
1-1/4" HW UP
3/4" HWR DOWN
3" V UP
1-1/2" CW UP
1-1/4" HW UP
3/4" HWR UP
4" SAN RISER
3" V UP
1" CW UP
1" HW UP
3/4" HWR DOWN
SERVICES FROM
TUNNEL BELOW
SERVICES FROM
TUNNEL BELOW
SERVICES FROM
TUNNEL BELOW
TIE THE EXT'G FIXTURES TO THE NEW SANITARY,
COLD WATER, AND HOT WATER SERVICES IN
TUNNEL. VERIFICATION IN FIELD IS REQUIRED.
IF ALT #1 IS ACCEPTED, NEW FIXTURES WILL BE
REQUIRED, SEE FIXTURE SCHEDULE FOR MORE
INFORMATION.
VERIFICATION IN FIELD IS REQUIRED.
RE-LOCATED EWH
3" SAN IN CEILING
ROUTE TO RISER S-1
3" SAN IN CEILING
ROUTE TO RISER S-1
INVESTIGATION IS
REQUIRED TO
DETERMINE IF THIS
SANITARY ROUTE IS
ACCEPTABLE AND
CONSTRUCTIBLE
INVESTIGATION IS
REQUIRED TO
DETERMINE IF THIS
SANITARY ROUTE IS
ACCEPTABLE AND
CONSTRUCTIBLE
3" V UP
3" V UP
W
W
CONTRACTOR TO VERIFY
EXT'G SERVICES IN THIS
LOCATION AND INCLUDE
NEW CW, HW, SAN, AND
VENTING FOR PLUMBING
FIXTURES
P200
DRAWING TITLE
KCT PROJECT NO.DRAWN
EHT
REVIEWED
DAR
DATE
SCALE
AS NOTED
DRAWING NO.
SEAL
SHEET NO.
NO. REVISIONS / SUBMISSIONS DATE
PROJECT NAME
PLUMBING
OVERALL TUNNEL &
C op yr ig ht
Ke nd ra C
. T ho m ps on A rc hi te ct s, P
.C
UPGRADE…
This is the start of the file's text. The full file is on GovTribe.