2113 Drawings.pdf
PDF 19 MB Posted
- Attached to
- Kenosha County Courthouse Campus Glass Repairs
- Solicitation number
- 2113
- Issued by
- Kenosha County, Kellnersville Village, Wisconsin
About this file
This is a set of architectural drawings for the Kenosha County Courthouse Campus Glass Damage Repairs project issued by InSite Consulting Architects for the County of Kenosha, Wisconsin. The project encompasses glass damage repairs across three buildings: the Kenosha County Courthouse (KCC), the Kenosha County Administration Building (KCAB), and the Public Safety Building (PSB), all located at 912 56th Street, Kenosha, Wisconsin 53140. The scope of work includes replacement of insulated glazing units with matching tint and coatings, replacement of spandrel glazing units with matching ceramic frit coatings, replacement of monolithic glass with code-compliant safety glass, installation of new bronze anodized doors and frames with ADA-compliant access operators and access control systems, replacement of bronze anodized window frame caps, inspection and replacement of fire-damaged frames and thermal breaks, and replacement of anodized aluminum trim on canopies. The drawings were issued for bidding on February 22, 2021, and include site context plans, elevations, and detailed damage documentation for each building. All work must comply with the State of Wisconsin Building Code and be coordinated with ongoing building operations.
The contractor is responsible for field verification of all dimensions, as-built drawing documentation with each pay request submission, coordination of temporary utility connections, protection of existing building features, and adherence to all safety and health regulations. Alternate bid pricing options are provided for enhanced security measures, including security film installation at glazing surfaces and forced-entry resistant laminated glass with polycarbonate alternatives. The contractor must submit an approved construction schedule and methods for protection prior to contract award, with owner approval required before work begins. The documents note that all replacement materials must match the original in color and finish, temporary plywood protection must be removed and frames restored, and landscape and paving areas must be restored to original condition upon project completion.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2113 Addendum 3.pdf | ||
| 2113 Specifications.pdf | ||
| Vendor Responsibility Form Construction.pdf | ||
| 2113 Bid Documents.pdf | ||
| 2113 Addendum 2.pdf | ||
| 2113 Adendum 1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A001
PROJECT LOCATION PLAN DIAGRAM
SCALE: 1" = 16'-0"
TITLE SHEET / CODE &
SHEET INDEX
A001
A001 TITLE SHEET / CODE & SHEET INDEX
A100A KCC SITE CONTEXT PLAN
A201A KCC SOUTH ELEVATION
A202A KCC WEST,EAST & NORTH ELEVATIONS
A100B KCAB SITE CONTEXT PLAN
A201B KCAB SOUTH ELEVATION
A202B KCAB EAST ELEVATION
A100C PSB SITE CONTEXT PLAN
A201C PSB SOUTHWEST ELEVATION
A202C PSB SOUTHEAST ELEVATION
KENOSHA, WISCONSIN 53715
GENERAL PROJECT NOTES:
KENOSHA COUNTY COURTHOUSE
CAMPUS
GLASS DAMAGE REPAIRS
1. ALL DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE STATE OF WISCONSIN BUILDING
CODE LATEST EDITION.
2. CONTRACTOR(S) ARE RESPONSIBLE FOR VERIFICATION OF, AND COORDINATION WITH, ALL DIMENSIONS
SHOWN ON THESE DRAWINGS RELATIVE TO EXISTING CONDITIONS PRIOR TO BEGINNING WORK. DO NOT
SCALE FROM DRAWINGS.
3. CONTRACTOR SHALL REPORT IMMEDIATELY TO THE ARCHITECT ANY DIMENSION(S) OR DISCREPANCIES
VERBALLY, A WRITTEN REPORT SHOULD PROMPTLY FOLLOW. CONTRACTOR SHALL CEASE WORK IN THE
AFFECTED AREA UNTIL DIRECTED BY THE ARCHITECT.
4. THE CONTRACTOR SHALL PROVIDE ALL METHODS AND EQUIPMENT FOR PROTECTING THE BUILDING, ALL
MATERIALS, AND PERSONNEL FROM FIRE OR OTHER DAMAGE PRIOR TO STARTING. THE CONTRACTOR
SHALL SUBMIT THE APPROVED METHODS AND EQUIPMENT IN WRITING FOR THE OWNER AND
ARCHITECT'S REVIEW PRIOR TO STARTING WORK.
5. THE CONTRACTOR SHALL COMPLY WITH ALL SAFETY AND HEALTH LAWS AND REGULATIONS.
6. EXECUTION OF THE WORK WILL INVOLVE CONSIDERATION FOR ALLOWING THE OWNER TO CONTINUE THE
OPERATION OF THE BUILDING AND THE BUSINESS IN THE FACILITY AND ADJACENT FACILITIES. PRIOR TO
THE AWARD OF THE CONTRACT, THE CONSTRUCTION SCHEDULE PREPARED BY THE CONTRACTOR SHALL
BE SUBMITTED TO THE ARCHITECT AND SHALL BE COORDINATED WITH THE OWNER. OWNER'S APPROVAL
OF THE PROPOSED SCHEDULE SHALL SUPERCEDE THE CONTRACT PROVIDED THE OVERALL TIME IS NOT
CHANGED.
7. THE CONTRACTOR SHALL REVIEW ALL EXISTING CONDITIONS TO DETERMINE ALL SERVICES (ELECTRICAL, MECHANICAL AND PLUMBING) AFFECTED BY THE REPAIR WORK. THE CONTRACTOR SHALL MAKE
NECESSARY TEMPORARY CONNECTIONS TO MAINTAIN EXISTING SERVICES TO ALL AREAS OF THE
BUILDING DIRECTLY AND INDIRECTLY AFFECTED BY THE WORK. THE CONTRACTOR SHALL SUBMIT
METHODS AND SCHEDULE OF CONNECTIONS TO THE OWNER FOR APPROVAL PRIOR TO BEGINNING
WORK.
8. AS THE WORK PROGRESSES, THE CONTRACTOR SHALL PRODUCE "AS-BUILT" DRAWINGS FOR THE
INSTALLATION OF ALL REPAIR ITEMS UNDER THE CONTRACT. THE ARCHITECT WILL PROVIDE THE
GENERAL CONTRACTOR WITH A SET OF REPRODUCIBLE PLANS FOR THIS PURPOSE. THE CONTRACTOR IS
RESPONSIBLE FOR MAINTAINING THE AS-BUILT DRAWINGS ACCORDING TO THE JOB PROGRESS. EACH
PAY REQUEST SUBMITTED BY THE CONTRACTOR SHALL BE ACCOMPANIED BY A COPY OF THE UPDATED
AS-BUILT DRAWINGS.
9. THE CONTRACTOR SHALL CALL "DIGGER'S HOTLINE" AT 800-242-8511, 48 HOURS (EXCLUDING WEEKENDS
AND/OR HOLIDAYS) PRIOR TO DIGGING ANY EXCAVATION. "DIGGER'S HOTLINE" WILL CONTACT UTILITY
COMPANIES TO LOCATE AND MARK THEIR UNDERGROUND FACILITIES. NO SUCH WORK SHALL COMMENCE
PRIOR TO VERIFICATION THAT ALL UTILITIES HAVE RESPONDED.
10.PROTECT TREES, SHRUBS, LAWNS, AND OTHER FEATURES WITHIN PROJECT LIMITS. RESTORE DAMAGED
FEATURES TO ORIGINAL CONDITION.
11.THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY ENCLOSURES, SHORING, BRACING, SHEATHING, REQUIRED FOR THE SAFETY AND PROPER EXECUTION OF THE WORK.
SHEET INDEX:
N
KENOSHA COUNTY PUBLIC SAFETY BUILDING (PSB)
KENOSHA COUNTY ADMINISTRATION BUILDING (KCAB)
KENOSHA COUNTY COURTHOUSE (KCC)
STRUCTURAL DRAWINGS - N/A
CIVIL DRAWINGS - N/A
MECHANICAL DRAWINGS - N/A
ELECTRICAL DRAWINGS - N/A
PLUMBING DRAWINGS - N/A
ICA NO. KCC 21-001
K E
N O
S H
A
C
O U
N T
Y
C
O U
R T
H O
U S
E
C
A M
P U
S
G
L A
S
D
A M
A G
E
R
E P
A I R
S
C O
U R
T H
O U
E
K
C C
P
U B
L I C
F
E T
Y
B
U I L
D I N
G
P
S B
C
O U
N T
Y
A
D M
I N
I S
T R
A T
I O
N
B
U I L
D I N
G
K
C A
B
InSite Consulting Architects
115 E. Main / STE 200
Madison, Wisconsin 53703
608-204-0825
608-531-1533 (fax) info@icsarc.com
I N
S I T
E
C
O N
S U
L T
I N
G
A
R C
H I T
E C
T S
NOTE: ALL DIMENSIONS GIVEN
SHALL BE CONSIDERED TO BE
"V.I.F." OR VERIFY-IN-FIELD
FEBRUARY 22, 2021
ISSUED FOR BIDDING
COURTHOUSE CAMPUS
KENOSHA, WI
S H
E R
I D
N
R
O A
D
56TH STREET
T
H
A
V E
N U
E
T
H
A
V E
N U
E
PROJECT LOCATION MAP
SCALE : NONE
A202A
ICA NO. KCC 21-001
K E
N O
S H
A
C
O U
N T
Y
C
O U
R T
H O
U S
E
C
A M
P U
S
G
L A
M
A G
E
R
E P
A I R
S
C O
U R
T H
O U
C C
P
U B
L
F
E T
Y
B
U I L D
I N
G
P
S B
C
O U
N T
Y
A
D M
I N
I S
T R
A T
I O
N
B
U I L D
I N
G
K
C A
B
InSite Consulting Architects
115 E. Main / STE 200
Madison, Wisconsin 53703
608-204-0825
608-531-1533 (fax) info@icsarc.com
I N
S I T
E
C
O N
S U
L T
I N
G
A
R C
H I T
E C
T S
NOTE: ALL DIMENSIONS GIVEN
SHALL BE CONSIDERED TO BE
"V.I.F." OR VERIFY-IN-FIELD
FEBRUARY 22, 2021
ISSUED FOR BIDDING
A202A
KCC SITE CONTEXT PLAN
A100A
A100A
KCC SITE CONTEXT PLAN
SCALE: 1/4" = 1'-0"
A201A
A202A
56TH STREET
S H
E R
I D
R
O A
D
T
H
A
V E
N U
E
N
KENOSHA COUNTY CAMPUS KEY PLAN
SCALE : NONE
KENOSHA COUNTY COURTHOUSE
(KCC)
(PSB)
(KCAB)
GENERAL PLAN NOTES
1. INSPECT ALL FRAMES ASSUMED TO BE REUSED FOR SIGNS OF
DAMAGE AND REPORT ANY DISCOVERED THAT IS NOT NOTED IN THE
DOCUMENTS TO THE ARCHITECT IMMEDIATELY
2. THE CONTRACTOR IS RESPONSIBLE FOR MAKING ALL FIELD
MEASUREMENTS TO ORDER AND INSTALL ALL REQUIRED MATERIALS
AND SYSTEMS
3. THE COLOR AND FINISH OF ALL REPLACEMENT MATERIALS IS
INTENDED TO MATCH THE ORIGINAL BEING REPLACED U.N.O.
4. PHOTO DOCUMENT AND SUBMIT PICTURES AT FIRST DAY OF
MOBILIZATION OF ALL WORK AREAS AND ADJACENT CONDITIONS
5. PAVING AND LANDSCAPING AREAS USED BY CONTRACTOR SHALL BE
RESTORED TO AT MINIMUM ORGINAL CONDITION AT COMPLETION OF
PROJECT
6. SEE TECHNICAL SPECIFICATIONS FOR DETAILED REQUIREMENTS
AND RESPONSIBILITIES
7. REMOVE ALL PLYWOOD PROTECTION FROM WINDOWS AND DOORS
ASSUMED TO NOT BE DAMAGED. INSPECT ALL GLAZING AND FRAMES
FOR DAMAGE AND REPORT ANY DISCOVERED DAMAGE TO THE
ARCHITECT IMMEDIATELY
SPECIFIC RESTORATION KEY NOTES
1. REPLACE INSULATED GLAZING UNIT WITH TINT AND COATING TO
MATCH EXISTING UNIT
2. REPLACE INSULATED SPANDREL GLAZING UNIT WITH TINT AND
CERAMIC FRIT COATING TO MATCH COLOR OF EXISTING UNIT
3. REPLACE MONOLITHIC GLASS UNIT WITH CODE COMPLIANT SAFETY
GLASS UNIT WITH TINT TO MATCH EXISTING UNIT
4. PROVIDE NEW BRONZE ANODIZED DOOR, FRAME AND HARDWARE TO
MATCH THE EXISTING CONFIGURATION AND FUNCTION INCLUDING
ADA ACCESS OPERATOR AND ACCESS CONTROL
5. PROVIDE NEW BRONZE ANODIZED DOOR AND SIDELITE FRAME AND
HARDWARE TO MATCH THE EXISTING CONFIGURATION AND
FUNCTION INCLUDING ADA ACCESS OPERATOR AND ACCESS
CONTROL
6. PROVIDE NEW BRONZE ANODIZED WINDOW FRAME CAP TO MATCH
THE EXISTING CONFIGURATION AND COLOR
7. INSPECT THE WALL AND FRAME FOR FIRE DAMAGE AND REPLACE IF
THERMAL BREAK, OPERATION OR ANCHORAGE HAVE BEEN
COMPROMISED
8. REPLACE ANODIZED ALUMINUM TRIM DAMAGED BY IMPACT ON FULL
EXTENTS OF CANOPY ON THREE SIDES. INSPECT SUBSTRATE AND
CONFIRM THAT NO UNDERLYING DAMAGE EXISTS
9. INSPECT FRAME AND HARDWARE FOR DAMAGE. REPORT ANY
UNFORESEEN DAMAGE TO THE ARCHITECT IMMEDIATELY
10. SEE ALTERNATE #B
11. SEE ALTERNATE #C
12. SEE GENERAL NOTES #1 AND #7
13. REMOVE ALL TEMPORARY PLYWOOD AND FASTENERS AND FILL ALL
FASTENER HOLES IN METAL FRAMES WITH COLOR MATCHED
SEALANT OR APPROVED FILLER
ALTERNATE PRICING KEY NOTES
ALT. #
· BASE BID IS FOR REPLACEMENT-IN-KIND OF ALL DAMAGED DOOR AND
WINDOW FRAMING AND GLAZING AND ADJACENT MATERIALS.
A. PROVIDE NEW VERTICAL MULLION AND GLAZING IN TWO LITES
(WHERE ONE CURRENTLY EXISTS)
B. PROVIDE SECURITY FILM AT INSIDE (#2 FOR MONOLITHIC AND #4 FOR
IGU) SURFACE OF GLAZING AT NOTED DOORS AND SIDELITES PER
SECTION 08 87 23.
C. PROVIDE NOMINAL 1/2" FORCED ENTRY RESISTANT LAMINATED
GLASS OVER POLYCARBONATE PER SECTION 08 88 53 IN LIEU OF THE
ENTRANCE GLAZING AT DOORS AND SIDELITES. CONFIRM THAT THE
FRAME IS CAPABLE OF ACCEPTING THE INSTALLATION AND
MAINTAINING THE GLAZING RATING
A202A
AutoCAD SHX Text A101
A201A
FIRST FLOOR RENOVATION PLAN
SCALE: 1/4" = 1'-0"
A
A201A
A201A
KCC SOUTH ELEVATION
SCALE: 1/4" = 1'-0"
ICA NO. KCC 21-001
K E
N O
S H
A
C
O U
N T
Y
C
O U
R T
H O
U S
E
C
A M
P U
S
G
L A
M
A G
E
R
E P
A I R
S
C O
U R
T H
O U
C C
P
U B
L
F
E T
Y
B
U I L D
I N
G
P
S B
C
O U
N T
Y
A
D M
I N
I S
T R
A T
I O
N
B
U I L D
I N
G
K
C A
B
InSite Consulting Architects
115 E. Main / STE 200
Madison, Wisconsin 53703
608-204-0825
608-531-1533 (fax) info@icsarc.com
I N
S I T
E
C
O N
S U
L T
I N
G
A
R C
H I T
E C
T S
NOTE: ALL DIMENSIONS GIVEN
SHALL BE CONSIDERED TO BE
"V.I.F." OR VERIFY-IN-FIELD
FEBRUARY 22, 2021
ISSUED FOR BIDDING
KCC SOUTH ELEVATION
A201A
A201A
B
A201A
D
A201A
F
A201A
G
A201A
A
A201A
B
A201A
D
A201A
E
A201A
F
A201A
G
A201A
C
A201A
C
A201A
E
A201A
3 49
VERIFY LOCATION AND CONDITION OF
FRAME DAMAGE
2 2
13 TYP.
13 TYP.
13 TYP.
13 TYP.
13 TYP.
A301
A202A
KCC WEST (PARTIAL) ELEVATION
SCALE: 1/8" = 1'-0"
A202A
NORTH ELEVATION (PARTIAL - EAST BAY)
SCALE: 1/8" = 1'-0"
ICA NO. KCC 21-001
K E
N O
S H
A
C
O U
N T
Y
C
O U
R T
H O
U S
E
C
A M
P U
S
G
L A
M
A G
E
R
E P
A I R
S
C O
U R
T H
O U
C C
P
U B
L
F
E T
Y
B
U I L D
I N
G
P
S B
C
O U
N T
Y
A
D M
I N
I S
T R
A T
I O
N
B
U I L D
I N
G
K
C A
B
InSite Consulting Architects
115 E. Main / STE 200
Madison, Wisconsin 53703
608-204-0825
608-531-1533 (fax) info@icsarc.com
I N
S I T
E
C
O N
S U
L T
I N
G
A
R C
H I T
E C
T S
NOTE: ALL DIMENSIONS GIVEN
SHALL BE CONSIDERED TO BE
"V.I.F." OR VERIFY-IN-FIELD
FEBRUARY 22, 2021
ISSUED FOR BIDDING
KCC WEST, EAST &
NORTH ELEVATIONS
A202A
A202A
KCC EAST ELEVATION
SCALE: 1/8" = 1'-0"
NOTE THAT THE FRAME AND THRESHOLD HAVE BEEN DISPLACED BY
IMPACT AND THERE IS SEPARATION FROM THE STRUCTURE AT JAMBS
105 8
1 9
13 TYP.
13 TYP.
13 TYP.
13 TYP.
13 TYP.
A301
A202B
ICA NO. KCC 21-001
K E
N O
S H
A
C
O U
N T
Y
C
O U
R T
H O
U S
E
C
A M
P U
S
G
L A
M
A G
E
R
E P
A I R
S
C O
U R
T H
O U
C C
P
U B
L
F
E T
Y
B
U I L D
I N
G
P
S B
C
O U
N T
Y
A
D M
I N
I S
T R
A T
I O
N
B
U I L D
I N
G
K
C A
B
InSite Consulting Architects
115 E. Main / STE 200
Madison, Wisconsin 53703
608-204-0825
608-531-1533 (fax) info@icsarc.com
I N
S I T
E
C
O N
S U
L T
I N
G
A
R C
H I T
E C
T S
NOTE: ALL DIMENSIONS GIVEN
SHALL BE CONSIDERED TO BE
"V.I.F." OR VERIFY-IN-FIELD
FEBRUARY 22, 2021
ISSUED FOR BIDDING
A201B
KCAB SITE CONTEXT PLAN
A100B
56TH STREET
T
H
A
V E
N U
E
N
A100B
KCAB SITE CONTEXT PLAN
SCALE: 1/4" = 1'-0"
KENOSHA COUNTY CAMPUS KEY PLAN
SCALE : NONE
KENOSHA COUNTY
ADMINISTRATION BUILDING
(KCAB)
(PSB)
(KCC)
GENERAL PLAN NOTES
1. INSPECT ALL FRAMES ASSUMED TO BE REUSED FOR SIGNS OF
DAMAGE AND REPORT ANY DISCOVERED THAT IS NOT NOTED IN THE
DOCUMENTS TO THE ARCHITECT IMMEDIATELY
2. THE CONTRACTOR IS RESPONSIBLE FOR MAKING ALL FIELD
MEASUREMENTS TO ORDER AND INSTALL ALL REQUIRED MATERIALS
AND SYSTEMS
3. THE COLOR AND FINISH OF ALL REPLACEMENT MATERIALS IS
INTENDED TO MATCH THE ORIGINAL BEING REPLACED U.N.O.
4. PHOTO DOCUMENT AND SUBMIT PICTURES AT FIRST DAY OF
MOBILIZATION OF ALL WORK AREAS AND ADJACENT CONDITIONS
5. PAVING AND LANDSCAPING AREAS USED BY CONTRACTOR SHALL BE
RESTORED TO AT MINIMUM ORGINAL CONDITION AT COMPLETION OF
PROJECT
6. SEE TECHNICAL SPECIFICATIONS FOR DETAILED REQUIREMENTS
AND RESPONSIBILITIES
7. REMOVE ALL PLYWOOD PROTECTION FROM WINDOWS AND DOORS
ASSUMED TO NOT BE DAMAGED. INSPECT ALL GLAZING AND FRAMES
FOR DAMAGE AND REPORT ANY DISCOVERED DAMAGE TO THE
ARCHITECT IMMEDIATELY
SPECIFIC RESTORATION KEY NOTES
1. REPLACE INSULATED GLAZING UNIT WITH TINT AND COATING TO
MATCH EXISTING UNIT
2. REPLACE INSULATED SPANDREL GLAZING UNIT WITH TINT AND
CERAMIC FRIT COATING TO MATCH COLOR OF EXISTING UNIT
3. REPLACE MONOLITHIC GLASS UNIT WITH CODE COMPLIANT SAFETY
GLASS UNIT WITH TINT TO MATCH EXISTING UNIT
4. PROVIDE NEW BRONZE ANODIZED DOOR, FRAME AND HARDWARE TO
MATCH THE EXISTING CONFIGURATION AND FUNCTION INCLUDING
ADA ACCESS OPERATOR AND ACCESS CONTROL
5. PROVIDE NEW BRONZE ANODIZED DOOR AND SIDELITE FRAME AND
HARDWARE TO MATCH THE EXISTING CONFIGURATION AND
FUNCTION INCLUDING ADA ACCESS OPERATOR AND ACCESS
CONTROL
6. PROVIDE NEW BRONZE ANODIZED WINDOW FRAME CAP TO MATCH
THE EXISTING CONFIGURATION AND COLOR
7. INSPECT THE WALL AND FRAME FOR FIRE DAMAGE AND REPLACE IF
THERMAL BREAK, OPERATION OR ANCHORAGE HAVE BEEN
COMPROMISED
8. REPLACE ANODIZED ALUMINUM TRIM DAMAGED BY IMPACT ON FULL
EXTENTS OF CANOPY ON THREE SIDES. INSPECT SUBSTRATE AND
CONFIRM THAT NO UNDERLYING DAMAGE EXISTS
9. INSPECT FRAME AND HARDWARE FOR DAMAGE. REPORT ANY
UNFORESEEN DAMAGE TO THE ARCHITECT IMMEDIATELY
10. SEE ALTERNATE #B
11. SEE ALTERNATE #C
12. SEE GENERAL NOTES #1 AND #7
13. REMOVE ALL TEMPORARY PLYWOOD AND FASTENERS AND FILL ALL
FASTENER HOLES IN METAL FRAMES WITH COLOR MATCHED
SEALANT OR APPROVED FILLER
ALTERNATE PRICING KEY NOTES
ALT. #
· BASE BID IS FOR REPLACEMENT-IN-KIND OF ALL DAMAGED DOOR AND
WINDOW FRAMING AND GLAZING AND ADJACENT MATERIALS.
A. PROVIDE NEW VERTICAL MULLION AND GLAZING IN TWO LITES
(WHERE ONE CURRENTLY EXISTS)
B. PROVIDE SECURITY FILM AT INSIDE (#2 FOR MONOLITHIC AND #4 FOR
IGU) SURFACE OF GLAZING AT NOTED DOORS AND SIDELITES PER
SECTION 08 87 23.
C. PROVIDE NOMINAL 1/2" FORCED ENTRY RESISTANT LAMINATED
GLASS OVER POLYCARBONATE PER SECTION 08 88 53 IN LIEU OF THE
ENTRANCE GLAZING AT DOORS AND SIDELITES. CONFIRM THAT THE
FRAME IS CAPABLE OF ACCEPTING THE INSTALLATION AND
MAINTAINING THE GLAZING RATING
A201B
KCAB SOUTH ELEVATION
SCALE: 1/8" = 1'-0"
ICA NO. KCC 21-001
K E
N O
S H
A
C
O U
N T
Y
C
O U
R T
H O
U S
E
C
A M
P U
S
G
L A
M
A G
E
R
E P
A I R
S
C O
U R
T H
O U
C C
P
U B
L
F
E T
Y
B
U I L D
I N
G
P
S B
C
O U
N T
Y
A
D M
I N
I S
T R
A T
I O
N
B
U I L D
I N
G
K
C A
B
InSite Consulting Architects
115 E. Main / STE 200
Madison, Wisconsin 53703
608-204-0825
608-531-1533 (fax) info@icsarc.com
I N
S I T
E
C
O N
S U
L T
I N
G
A
R C
H I T
E C
T S
NOTE: ALL DIMENSIONS GIVEN
SHALL BE CONSIDERED TO BE
"V.I.F." OR VERIFY-IN-FIELD
FEBRUARY 22, 2021
ISSUED FOR BIDDING
KCAB SOUTH ELEVATION
A201B
A201B
KCAB SOUTH ENTRY VIEW
SCALE: N.T.S.
X
A3xx
A201B
A
A201B
A
A201B
B
A201B
B
A201B
A201B
KCAB SOUTH EAST VIEW
SCALE: N.T.S.
E
A201B
E
A201B
A201B
KCAB SOUTH WEST VIEW
SCALE: N.T.S.
D
A201B
D - INTERIOR
A201B
C
A201B
C
A201B
5 31
X
A3xx
A201B
X
A3xx
A201B
A201B
KCAB SOUTH WEST VIEW
SCALE: N.T.S.
A201B
KCAB SOUTH EAST VIEW
SCALE: N.T.S.
X
A3xx
A201B
X
A3xx
A201B
ALT. #A ALT. #A ALT. #A ALT. #A ALT. #A
13 TYP.
13 TYP.
13 TYP.
13 TYP.
13 TYP.
13 TYP.
ALT. B
ALT. C
ALT. B
ALT. C
51 53
53 53
51 51
13 TYP.
13 TYP.
A201B
13 TYP.
13 TYP.
DAMAGE VIEW FROM INTERIOR
DAMAGE VIEW FROM INTERIOR
AutoCAD SHX Text A301
FIRST FLOOR RENOVATION PLAN
A202B
KCAB EAST ELEVATION
SCALE: 1/8" = 1'-0"
ICA NO. KCC 21-001
K E
N O
S H
A
C
O U
N T
Y
C
O U
R T
H O
U S
E
C
A M
P U
S
G
L A
M
A G
E
R
E P
A I R
S
C O
U R
T H
O U
C C
P
U B
L
F
E T
Y
B
U I L D
I N
G
P
S B
C
O U
N T
Y
A
D M
I N
I S
T R
A T
I O
N
B
U I L D
I N
G
K
C A
B
InSite Consulting Architects
115 E. Main / STE 200
Madison, Wisconsin 53703
608-204-0825
608-531-1533 (fax) info@icsarc.com
I N
S I T
E
C
O N
S U
L T
I N
G
A
R C
H I T
E C
T S
NOTE: ALL DIMENSIONS GIVEN
SHALL BE CONSIDERED TO BE
"V.I.F." OR VERIFY-IN-FIELD
FEBRUARY 22, 2021
ISSUED FOR BIDDING
KCAB EAST ELEVATION
A202B
A202B
KCAB EAST (SOUTH) VIEW
SCALE: N.T.S.
X
A3xx
A202B
A
A202B
A
A202B
B
A202B
X
A3xx
A202B
A202B
KCAB EAST (SOUTH) VIEW
SCALE: N.T.S.
B
A202B
X
A3xx
B
A202B
AutoCAD SHX Text
AutoCAD SHX Text A.D.
AutoCAD SHX Text A301
ICA NO. KCC 21-001
E
N O
S H
A
C
O U
N T
Y
C
O U
R T
H O
U S
E
C
A M
P U
S
G
L A
M
A G
E
R
E P
A I R
S
C O
U R
T H
O U
C C
P
U B
L
F
E T
Y
B
U I L D
I N
G
P
S B
C
O U
N T
Y
A
D M
I N
I S
T R
A T
I O
N
B
U I L D
I N
G
K
C A
B
InSite Consulting Architects
115 E. Main / STE 200
Madison, Wisconsin 53703
608-204-0825
608-531-1533 (fax) info@icsarc.com
I N
S I T
E
C
O N
S U
L T
I N
G
A
R C
H I T
E C
T S
NOTE: ALL DIMENSIONS GIVEN
SHALL BE CONSIDERED TO BE
"V.I.F." OR VERIFY-IN-FIELD
FEBRUARY 22, 2021
ISSUED FOR BIDDING
PSB SITE CONTEXT PLAN
A100C
N
A100C
PSB SITE CONTEXT PLAN
SCALE: 1/4" = 1'-0"
A201C
55TH STREET
T
H
A
V E
N U
E
N
KENOSHA COUNTY CAMPUS KEY PLAN
SCALE : NONE
KENOSHA PUBLIC SAFETY BUILDING
(PSB)
(KCAB)
T
H
A
V E
N U
E
A100C
PSB SITE CONTEXT VIEW
SCALE: NOT TO SCALE
A100C
(KCC)
GENERAL PLAN NOTES
1. INSPECT ALL FRAMES ASSUMED TO BE REUSED FOR SIGNS OF
DAMAGE AND REPORT ANY DISCOVERED THAT IS NOT NOTED IN THE
DOCUMENTS TO THE ARCHITECT IMMEDIATELY
2. THE CONTRACTOR IS RESPONSIBLE FOR MAKING ALL FIELD
MEASUREMENTS TO ORDER AND INSTALL ALL REQUIRED MATERIALS
AND SYSTEMS
3. THE COLOR AND FINISH OF ALL REPLACEMENT MATERIALS IS
INTENDED TO MATCH THE ORIGINAL BEING REPLACED U.N.O.
4. PHOTO DOCUMENT AND SUBMIT PICTURES AT FIRST DAY OF
MOBILIZATION OF ALL WORK AREAS AND ADJACENT CONDITIONS
5. PAVING AND LANDSCAPING AREAS USED BY CONTRACTOR SHALL BE
RESTORED TO AT MINIMUM ORGINAL CONDITION AT COMPLETION OF
PROJECT
6. SEE TECHNICAL SPECIFICATIONS FOR DETAILED REQUIREMENTS
AND RESPONSIBILITIES
7. REMOVE ALL PLYWOOD PROTECTION FROM WINDOWS AND DOORS
ASSUMED TO NOT BE DAMAGED. INSPECT ALL GLAZING AND FRAMES
FOR DAMAGE AND REPORT ANY DISCOVERED DAMAGE TO THE
ARCHITECT IMMEDIATELY
SPECIFIC RESTORATION KEY NOTES
1. REPLACE INSULATED GLAZING UNIT WITH TINT AND COATING TO
MATCH EXISTING UNIT
2. REPLACE INSULATED SPANDREL GLAZING UNIT WITH TINT AND
CERAMIC FRIT COATING TO MATCH COLOR OF EXISTING UNIT
3. REPLACE MONOLITHIC GLASS UNIT WITH CODE COMPLIANT SAFETY
GLASS UNIT WITH TINT TO MATCH EXISTING UNIT
4. PROVIDE NEW BRONZE ANODIZED DOOR, FRAME AND HARDWARE TO
MATCH THE EXISTING CONFIGURATION AND FUNCTION INCLUDING
ADA ACCESS OPERATOR AND ACCESS CONTROL
5. PROVIDE NEW BRONZE ANODIZED DOOR AND SIDELITE FRAME AND
HARDWARE TO MATCH THE EXISTING CONFIGURATION AND
FUNCTION INCLUDING ADA ACCESS OPERATOR AND ACCESS
CONTROL
6. PROVIDE NEW BRONZE ANODIZED WINDOW FRAME CAP TO MATCH
THE EXISTING CONFIGURATION AND COLOR
7. INSPECT THE WALL AND FRAME FOR FIRE DAMAGE AND REPLACE IF
THERMAL BREAK, OPERATION OR ANCHORAGE HAVE BEEN
COMPROMISED
8. REPLACE ANODIZED ALUMINUM TRIM DAMAGED BY IMPACT ON FULL
EXTENTS OF CANOPY ON THREE SIDES. INSPECT SUBSTRATE AND
CONFIRM THAT NO UNDERLYING DAMAGE EXISTS
9. INSPECT FRAME AND HARDWARE FOR DAMAGE. REPORT ANY
UNFORESEEN DAMAGE TO THE ARCHITECT IMMEDIATELY
10. SEE ALTERNATE #B
11. SEE ALTERNATE #C
12. SEE GENERAL NOTES #1 AND #7
13. REMOVE ALL TEMPORARY PLYWOOD AND FASTENERS AND FILL ALL
FASTENER HOLES IN METAL FRAMES WITH COLOR MATCHED
SEALANT OR APPROVED FILLER
ALTERNATE PRICING KEY NOTES
ALT. #
· BASE BID IS FOR REPLACEMENT-IN-KIND OF ALL DAMAGED DOOR AND
WINDOW FRAMING AND GLAZING AND ADJACENT MATERIALS.
A. PROVIDE NEW VERTICAL MULLION AND GLAZING IN TWO LITES
(WHERE ONE CURRENTLY EXISTS)
B. PROVIDE SECURITY FILM AT INSIDE (#2 FOR MONOLITHIC AND #4 FOR
IGU) SURFACE OF GLAZING AT NOTED DOORS AND SIDELITES PER
SECTION 08 87 23.
C. PROVIDE NOMINAL 1/2" FORCED ENTRY RESISTANT LAMINATED
GLASS OVER POLYCARBONATE PER SECTION 08 88 53 IN LIEU OF THE
ENTRANCE GLAZING AT DOORS AND SIDELITES. CONFIRM THAT THE
FRAME IS CAPABLE OF ACCEPTING THE INSTALLATION AND
MAINTAINING THE GLAZING RATING
A201C
PSB PARTIAL SOUTH ELEVATION
SCALE: N.T.S.
ICA NO. KCC 21-001
K E
N O
S H
A
C
O U
N T
Y
C
O U
R T
H O
U S
E
C
A M
P U
S
G
L A
M
A G
E
R
E P
A I R
S
C O
U R
T H
O U
C C
P
U B
L
F
E T
Y
B
U I L D
I N
G
P
S B
C
O U
N T
Y
A
D M
I N
I S
T R
A T
I O
N
B
U I L D
I N
G
K
C A
B
InSite Consulting Architects
115 E. Main / STE 200
Madison, Wisconsin 53703
608-204-0825
608-531-1533 (fax) info@icsarc.com
I N
S I T
E
C
O N
S U
L T
I N
G
A
R C
H I T
E C
T S
NOTE: ALL DIMENSIONS GIVEN
SHALL BE CONSIDERED TO BE
"V.I.F." OR VERIFY-IN-FIELD
FEBRUARY 22, 2021
ISSUED FOR BIDDING
PSB - SOUTHWEST
ELEVATION
A201C
A201C
PSB PARTIAL SOUTH PERSPECTIVE
SCALE: N.T.S.
ALT. B
ALT. C
13 TYP.
A201C
PSB INTERIOR OF S. ENTRANCE
SCALE: N.T.S.
AutoCAD SHX Text A301
A202C
PSB PARTIAL SOUTH ELEVATION
SCALE: N.T.S.
ICA NO. KCC 21-001
K E
N O
S H
A
C
O U
N T
Y
C
O U
R T
H O
U S
E
C
A M
P U
S
G
L A
M
A G
E
R
E P
A I R
S
C O
U R
T H
O U
C C
P
U B
L
F
E T
Y
B
U I L D
I N
G
P
S B
C
O U
N T
Y
A
D M
I N
I S
T R
A T
I O
N
B
U I L D
I N
G
K
C A
B
InSite Consulting Architects
115 E. Main / STE 200
Madison, Wisconsin 53703
608-204-0825
608-531-1533 (fax) info@icsarc.com
I N
S I T
E
C
O N
S U
L T
I N
G
A
R C
H I T
E C
T S
NOTE: ALL DIMENSIONS GIVEN
SHALL BE CONSIDERED TO BE
"V.I.F." OR VERIFY-IN-FIELD
FEBRUARY 22, 2021
ISSUED FOR BIDDING
PSB - SOUTHEAST
ELEVATION
A202C
A202C
PSB PARTIAL SOUTH ELEVATION
SCALE: N.T.S.
X
A3xx
A202C
A202C
PSB PARTIAL SOUTH (WEST) ELEVATION
SCALE: N.T.S.
X
A3xx
2&3
A202C
13 TYP.
A202C
PSB PARTIAL NORTH ELEVATION (NOT SHOWN)
SCALE: N.T.S.
A202C
PSB PARTIAL WEST ELEVATION (NOT SHOWN)
SCALE: N.T.S.
13 TYP.
REMOVE
TEMPORARY
PLYWOOD
PROTECTION AND
RESTORE FRAMES
WITH COLOR
MATCHED FILLER AT
ENTRY DOOR
FRAME.
13 TYP.
REMOVE
TEMPORARY
PLYWOOD
PROTECTION AND
RESTORE FRAMES
WITH COLOR
MATCHED FILLER AT
ENTRY DOOR AND
SIDELITE FRAMES.
AutoCAD SHX Text A301
| Sheets and Views |
| A001 TITLE SHEET-A001 TITLE SHEET |
| KCC-GDR_Set-A100A-Site Plan |
| KCC-GDR_Set-A201A |
| KCC-GDR_Set-A202A |
| KCAB-GDR_Set-A100B-Site Plan |
| KCAB-GDR_Set-A201B |
| KCAB-GDR_Set-A202B |
| PSB-GDR_Set-A100C-Site Plan |
| PSB-GDR_Set-A201C |
| PSB-GDR_Set-A202C |
File details come from the government source that posted it. Updated .