210604_-_RHC_-_Elevators_-_02-11-2022_-_BID_DRAWINGS.pdf

PDF 6 MB Posted

Attached to
Regional History Center Elevator Modernization
Solicitation number
Y22-7038
Issued by
Orange County, Orlando City, Florida

About this file

These are bid drawings for the Regional History Center Elevator Modernization project for Orange County, Florida, prepared by KMF Architects and SGM Engineering. The documents detail comprehensive elevator modernization work for the Orange County Regional History Center located at 65 East Central Boulevard in Orlando. The project involves modifying two existing elevators, including interior cab renovations, installation of new digital wayfinding panels, replacement of call buttons and indicators, and electrical system updates across five floors and a roof machine room. The drawings specify detailed modifications to elevator cab interiors, electrical systems, lighting, power distribution, and plumbing components.

The project is estimated to cost $750,000.00, with sealed offers to be electronically submitted via the OpenGov e-Procurement Platform by 4:00 pm EST on Tuesday, August 30, 2022. Technical specifications include replacing existing elevator equipment with new stainless steel wall panels, handrails, control panels, and digital monitors, as well as updating electrical infrastructure like disconnect switches, circuit breakers, and power connections. The drawings provide comprehensive technical details for contractors, including electrical one-line diagrams, panel schedules, symbol legends, and specific installation requirements for elevator, electrical, and plumbing systems. The scope encompasses complete modernization of the building's vertical transportation infrastructure while maintaining the historical center's operational capabilities.

View the file

Other files

File Type Posted
210604_-_RHC_-_Elevators_-_02-11-2022_-_BID_SPECS.pdf PDF
Y22-7038_final.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Orange County Regional History Center Elevator Modifications

65 EAST CENTRAL BOULEVARD

ORLANDO, FLORIDA 32801

ORANGE COUNTY

BOARD OF COMISSIONERS

201 South Rosalind Avenue Orlando, FL 32801

(407) 836-7350

OWNER CONTACT

KMF ARCHITECTS

1401 EDGEWATER DRIVE

ORLANDO, FL, 32804

(407) 802 - 6058

LIC # AA0003374

ARCHITECTURE

SGM Engineering, Inc, 935 Lake Baldwin Lane Orlando, FL 32814

(407) 767-5188

MECHANICAL & ELECTRICAL

LEVEL 2 INTERIOR ALTERATIONS

65 EAST CENTRAL BOULEVARD

ORLANDO, FL. 32801

ORANGE COUNTY REGIONAL HISTORY CENTER ELEVATOR

MODERNIZATION

CODES IN EFFECT:

SCOPE OF PROJECT:

ADDRESS:

PROJECT:

ORANGE COUNTY BOARD OF COMISSIONERS, 407.836.7350CLIENT CONTACT:

ERIC KLEINSTEUBER, AIA KMF ARCHITECTS, 407.298.1988ARCHITECT CONTACT:

BUILDING CODE ANALYSIS

- 2020 FLORIDA BUILDING CODE, BUILDING, 7TH EDITION

- 2020 FLORIDA EXISTING BUILDING CODE, 7TH EDITION

- 2020 FLORIDA BUILDING CODE, ACCESSIBILITY, 7TH EDITION

- NATIONAL ELECTRIC CODE 2017 NFPA 70

- FLORIDA FIRE PREVENTION CODE, 7TH EDITION

NFPA 1 FIRE CODE, 2018 EDITION

NFPA 101 LIFE SAFETY CODE, 2018 EDITION

(ADOPTED DECEMBER 31, 2020) PLUS AMENDMENTS

BUILDING OCCUPANCY TYPE: BUSINESS B EXISTING BUILDING

CODE DATA:

SECTION NUMBER

SECTIONS

ELEVATION NUMBERS

ELEVATIONS

DETAIL NUMBER

ROOM NUMBERS

DIRECTION OF ELEVATION VIEWS

DRAWING WHERE

ELEVATION IS SHOWN

DRAWING WHERE ELEVATION IS

SHOWN

DRAWING

WHERE

SECTION IS

SHOWN

DRAWING WHERE

DETAIL IS SHOWN

DOOR & OPENING NUMBERSINTERIOR PARTITIONS

REVISIONS

LETTER INDICATES

INTERIOR PARTITION TYPE

NUMBER INDICATES

STRUCTURE DEPTH.

ISSUE IN WHICH REVISION OCCURS

WINDOW TYPE

CLOUD SURROUNDING

AREA OF CURRENT

REVISION

XX

XXXX

XX

XXXX

XX

XXXX

GENERAL INTERIOR FINISH

TAG

ROOM NAMEREST

ROOM

ROOM NUMBER - FIRST

DIGIT INDICATES FLOOR

OR LEVEL

DETAILS

DIRECTION

OF SECTION

CUT

REFERENCE SYMBOLS

F0 W0 C0

B0 T0 R0 CEILING FINISH

REMARK

WALL FINISH; WHERE

APPLICABLE REFER TO ACCENT

WALL TAG FOR SPECIFIC WALL

TREATMENT

FLOOR FINISH

TRIM

WALL BASE

INTERIOR FINISH ACCENT

WALL TAG

DIRECTION OF

ELEVATION VIEW

ELEVATION

NUMBER

FINISH TYPE

DASHED LINE INDICATES

EXTENT

OF SURFACE TO RECEIVE

SPECIFIED FINISH TYPE

Z0

XX

XXXX

A6

ERIC KLEINSTEUBER

FL LICENSE # AR93580

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

PA

R

C

EL

ID

6-

-2

9-

-0

0-

PARCEL ID : 26-22-29-6221-00-010

O ra ng e

C ou nt y

R eg io na l H is to ry

C en te r

E

AS

T

C

EN

TR

AL

B O

U

LE

VA

R

D O

R

LA

N D

O , F

L

El ev at or

M od er ni za tio n

COVER SHEET,

DRAWING INDEX,

AERIAL VICINTY

MAP

210604 11/02/21

G.000 01

ARCHITECTURAL

SHEET

NO. SHEET NAME

ISSUE

NO.

RELEASE

DATE

G.000 COVER SHEET, DRAWING INDEX, AERIAL VICINTY MAP 01 11/02/21

A.101 FLOOR PLAN 01 11/02/21

A.401 ENLARGED ELEVATIONS 01 11/02/21

A.402 ENLARGED INTERIOR PLANS AND ELEVATIONS 01 11/02/21

A.403 ADDITIONAL ELEVATIONS 01 11/02/21

A.404 SPECIALTY SECTIONS AND DETAILS 01 11/02/21

PROJECT

LOCATION

VICINITY MAP

# DATE DESCRIPTION

01 2021.11.02 PERMIT &

CONSTRUCT.

ELECTRICAL

SHEET

NO. SHEET NAME

ISSUE

NO.

RELEASE

DATE

ED.201 ELECTRICAL DEMO LIGHTING PLANS 01 11/02/21

ED.301 ELECTRICAL DEMO POWER PLANS 01 11/02/21

E.001 ELECTRICAL SYMBOLS LEGEND 01 11/02/21

E.201 ELECTRICAL LIGHTING PLANS 01 11/02/21

E.301 ELECTRICAL POWER PLANS 01 11/02/21

E.501 ELECTRICAL ONE-LINE DIAGRAMS 01 11/02/21

E.701 ELECTRICAL PANEL SCHEDULES 01 11/02/21

E.801 ELECTRICAL DETAILS 01 11/02/21

PLUMBING

SHEET

NO. SHEET NAME

ISSUE

NO.

RELEASE

DATE

P.001 PLUMBING SYMBOLS LEGEND 01 11/02/21

P.301 PLUMBING FLOOR PLANS 01 11/02/21

OPENING

4' - 5 11/16" F.V.

OPENING

4' - 5 11/16" F.V.

1'

1/

2"

HOISTWAY CLEAR WIDTH

9' - 2 5/16"9' - 2 5/16"

DIVIDER BEAM

8"

AD.1

1'

1/

2"

AD.2AD.2

AD.3TYP.

AD.3TYP.

AD.4TYP.

AD.4TYP.

AD.2 AD.2

AD.3 TYP.

AD.3 TYP.

AD.4 TYP.

AD.4 TYP.

AD.1

PLATFORM WIDTH

5' - 10 3/4" F.V.

PLATFORM WIDTH

5' - 10 3/4" F.V.

8'

6"

8'

6"

WALL BARRIER TO WALL BARRIER

5' - 10 3/4"

F.

V.

WALL BARRIER TO WALL BARRIER

5' - 10 3/4"

F.

V.

AD.5

AD.5

AD.5

AD.5

8'

6" F

.V

8'

6"

F.

V.

F.

V.

F.

V.

F.

V.

OPENING

4' - 5 11/16" F.V.

OPENING

4' - 5 11/16" F.V.

PLATFORM WIDTH

5' - 10 3/4" F.V.

8'

6"

1'

1/

2"

PLATFORM WIDTH

5' - 10 3/4" F.V.

HOISTWAY CLEAR WIDTH

9' - 2 5/16" F.V.

HOISTWAY CLEAR WIDTH

10' - 2 5/16"

DIVIDER BEAM

8"

3/

4"

1/

2"

8'

3"

WALL BARRIER TO WALL BARRIER

5' - 10 3/4"

WALL BARRIER TO WALL BARRIER

5' - 10 3/4" 1 1

2 2 2 2

3 TYP.

3 TYP.

6 TYP.

6 TYP.

3TYP.

6TYP.

1/

2" 2'

8"

1/

2" 2'

8"

1/

2" 2'

8"

1/

2"

1'

1/

2"

1/

2" 2'

8"

1/

2" 2'

8"

1/

2" 2'

8"

1/

2"

3/4"3/4"3/4" 3/4"

3TYP.

6TYP.

GENERAL NOTES

1. GENERAL NOTES APPLY TO ALL

DRAWINGS

2. THE GENERAL CONTRACTOR SHALL

COORDINATE CUT-OUTS FOR

CASEWORK, MILLWORK, OR OTHER

EQUIPMENT AS REQUIRED.

3. ALL ASPECTS OF THE WORK AND ITEMS

NOT SPECIFICALLY MENTIONED, BUT

WHICH ARE NECESSARY TO MAKE A

COMPLETE WORKING INSTALLATION,

SHALL BE INCLUDED, AND INDICATED IN

THE CONTRACTORS BID.

4. NO ASBESTOS OR PCB CONTAINING

MATERIALS SHALL BE USED ON THIS

PROJECT.

5. THE GENERAL CONTRACTOR AND ALL

SUBCONTRACTORS ARE RESPONSIBLE

FOR PROPER REMOVAL AND DISPOSAL

OF ALL DEBRIS GENERATED BY

CONSTRUCTION OF THIS PROJECT. THE

REMOVAL AND DISPOSAL OF ALL

CONSTRUCTION DEBRIS SHALL BE IN

FULL COMPLIANCE WITH ALL FEDERAL,

STATE AND LOCAL REGULATIONS. THE

PREMISES SHALL BE KEPT CLEAN AND

FREE FROM ALL WASTE MATERIALS.

6. GENERAL CONTRACTOR SHALL

PROTECT NEW CONSTRUCTION FROM

DAMAGE BY ALL TRADES. ALL SUCH

DAMAGE CAUSED BY THE CONTRACTOR

DURING THE COURSE OF THIS WORK

SHALL BE REPAIRED OR REPLACED AT

THE CONTRACTORS EXPENSE.

7. CONTRACTOR IS RESPONSIBLE FOR

FIELD VERIFICATION OF ALL

DIMENSIONS AND FIELD CONDITIONS

PRIOR TO ORDERING OR INSTALLING

MATERIALS OR EQUIPMENT.

8. ALL PIPING AND CONDUITS SHALL BE

CONCEALED WITHIN WALLS,

UNDERGROUND, ABOVE CEILINGS OR IN

ARCHITECT APPROVED UTILITY SPACES

IN ALL CASES UNLESS SPECIFICALLY

NOTED OTHERWISE ON THE DRAWINGS.

EXPOSED ITEMS MUST BE LOCATED IN .

ALL EXPOSED ITEMS ARE TO BE

PAINTED TO MATCH THE ADJACENT

SURFACES UNLESS SCHEDULED FOR

AN ACCENT COLOR.

FINISH NOTES

KEY NOTES

DEMO KEY NOTES

AD.1

AD.2

AD.3

NEW FLOORING TO BE INSTALLED

NEW STAINLESS STEEL SIDE WALL

PANELS TO BE INSTALLED

NEW STAINLESS STEEL INTERIOR

CAB DOOR PANELS TO BE

INSTALLED

NEW ALUMINUM SILLS TO BE

INSTALLED

NEW STAINLESS STEEL CAB

INTERIOR CONTROL PANEL TO BE

INSTALLED

EXISTING EXTERIOR DOOR PANELS

TO REMAIN

NEW BLACK LAMINATE RECESSED

CEILING REVEAL TO BE INSTALLED

NEW STAINLESS STEEL CEILING

PANELS TO BE INSTALLED

NEW WHITE LAMINATE CEILING

SOFFIT TO BE INSTALLED

NEW SQUARE LED LIGHT FIXTURE

NEW BLACK LAMINATE RECESSED

CEILING REVEAL TO BE INSTALLED

EXISTING VINYL FLOORING TO BE

REMOVED

EXISTING WOOD SIDE WALL PANELS

TO BE REMOVED

EXISTING INTERIOR CAB DOORS

AND SILLS TO BE REMOVED

EXISTING CAB INTERIOR CONTROL

PANEL TO BE REMOVED

EXISTING LED DOWNLIGHT CEILING

PANELS TO BE REMOVED

AD.4

FLOORING

MFR: MILLIKEN

STYLE: CHARLOTTE

COLOR: CHT209

INSTALL PATTERN: BRICK PATTERN

CAB SIDE WALL PANELS + CEILING

PANELS

MFR: TBD

STYLE: STAINLESS STEEL

COLOR: TBD

CAB WALL/ CEILING REVEAL PANELS

MFR: WILSON ART

STYLE: BLACKBIRD

COLOR: 5024

INTERIOR CAB DOOR PANELS

MFR: TBD

STYLE: STAINLESS STEEL

COLOR: TBD

CAB SOFFIT PANELS

MFR: WILSON ART

STYLE: FROSTY WHITE

COLOR: 1573

CAB CEILING LIGHTS

MFR: MAN-D-TEC

STYLE: S^2 BEAM

COLOR: STAINLESS STEEL/ALUMINUM

CONTROL PANEL BUTTONS

MFR: INNOVATION

STYLE: BRUISER HALO SERIES

COLOR: PB-72, ILLUMINATION: GREEN

FLOOR/DIRECTION INDICATOR BUTTON

MFR: TBD

STYLE: TBD

COLOR: TBD

DIGITAL T.V. WAYFINDING PANEL

MFR: SAMSUNG

STYLE: Q60A QLED SMART TV

COLOR: BLACK

AD.5

WALL BARRIER TO WALL BARRIER

5' - 10 3/4"

WALL BARRIER TO WALL BARRIER

5' - 10 3/4"

8'

6"

4' - 9 1/4" 3 1/4"3 1/4"

F.V. F.V.

11 TYP.

10 TYP.

94' - 5 3/4"

1'

6" 1"

1'

6" 1"

1'

6" 1"

1'

6" 1"

1'

6"

8 8'

6"

10TYP.

1'

6" 1"

1'

6" 1"

1'

6" 1"

1'

6" 1"

1'

6"

4' - 5 3/4" F.V. F.V.

4' - 9 1/4" 3 1/4"3 1/4" 11TYP.

ERIC KLEINSTEUBER

FL LICENSE # AR93580

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

PA

R

C

EL

ID

6-

-2

9-

-0

0-

O ra ng e

C ou nt y

R eg io na l H is to ry

C en te r

E

AS

T

C

EN

TR

AL

B O

U

LE

VA

R

D O

R

LA

N D

O , F

L

El ev at or

M od er ni za tio n

FLOOR PLAN

210604 11/02/21

A.101 011/2" = 1'-0" 03INTERIOR CAB PLAN DEMO NOTES

1/2" = 1'-0" 04INTERIOR CAB REFLECTED CEILING PLAN DEMO

1/2" = 1'-0" 01INTERIOR CAB PLAN0 1' 2' 4'

0 1' 2' 4'0 1' 2' 4'

0 1' 2' 4'

1/2" = 1'-0" 02INTERIOR CAB REFLECTED CEILING PLAN

NOTE: IF SOFFIT IS NOT PERMISSABLE TO

CONSTRUCT BECAUSE OF ESCAPE HATCH

LOCATION, PLEASE REVERT TO LED

DOWNLIGHT CEILING OPTION

# DATE DESCRIPTION

01 2021.11.02 PERMIT &

CONSTRUCT.

LEVEL 1

0"

LEVEL 2

12' - 0"

LEVEL 4

34' - 6"

LEVEL 3

24' - 0"

LEVEL 5

46' - 6"

08 /A.401

07 /A.401

06 /A.401

05 /A.401

04 /A.401

LEVEL 1

0"

DIGITAL WAYFINDING PANEL-

WALL MOUNTED SAMSUNG Q60A

NEW INDICATOR BUTTONS WALL FINISH TO REMAIN

CROWN MOLDING TO

REMAIN

NEW FIRE BUTTON

NEW CALL BUTTONS-BRUISER

INNOVATION PB-72 BUTTONS

EXISTING DOOR FINISH TO REMAIN

LEVEL 2

12' - 0"

DIGITAL WAYFINDING PANEL-

WALL MOUNTED SAMSUNG Q60AD

NEW INDICATOR BUTTONS

NEW FIRE BUTTON

NEW CALL BUTTONS-BRUISER

INNOVATION PB-72 BUTTONS

EXISTING DOOR FINISH TO REMAIN

WALL FINISH TO REMAIN

CROWN MOLDING TO

REMAIN

LEVEL 3

24' - 0"

DIGITAL WAYFINDING PANEL-WALL

MOUNTED SAMSUNG Q60A

NEW INDICATOR BUTTONS

NEW FIRE BUTTON

NEW CALL BUTTONS-BRUISER

INNOVATION PB-72 BUTTONS

EXISTING DOOR FINISH TO REMAIN

WALL FINISH TO REMAIN

CROWN MOLDING TO

REMAIN

LEVEL 4

34' - 6"

DIGITAL WAYFINDING PANEL-WALL

MOUNTED SAMSUNG Q60A

NEW INDICATOR BUTTONS

NEW FIRE BUTTON

NEW CALL BUTTONS-BRUISER

INNOVATION PB-72 BUTTONS

EXISTING DOOR FINISH TO REMAIN

WALL FINISH TO REMAIN

CROWN MOLDING TO

REMAIN

LEVEL 5

46' - 6"

NEW INDICATOR BUTTONS

NEW FIRE BUTTON

NEW CALL BUTTONS-BRUISER

INNOVATION PB-72 BUTTONS

EXISTING DOOR FINISH TO REMAIN

COLUMN TO REMAIN

WALL FINISH +

MOLDING TO REMAIN

LEVEL 1

0"

REMOVE WAYFINDING PANEL

REMOVE INDICATOR BUTTONS

REMOVE FIRE BUTTONS

REMOVE CALL BUTTONS

LEVEL 2

12' - 0"

REMOVE WAYFINDING PANEL

REMOVE INDICATOR BUTTONS

REMOVE FIRE BUTTONS

REMOVE CALL BUTTONS

LEVEL 3

24' - 0"

REMOVE WAYFINDING PANEL

REMOVE INDICATOR BUTTONS

REMOVE FIRE BUTTONS

REMOVE CALL BUTTONS

LEVEL 4

34' - 6"

REMOVE WAYFINDING PANEL

REMOVE INDICATOR BUTTONS

REMOVE FIRE BUTTON

REMOVE CALL BUTTONS

LEVEL 5

46' - 6"

REMOVE WAYFINDING PANEL

REMOVE INDICATOR BUTTONS

REMOVE FIRE BUTTON

REMOVE CALL BUTTONS

GENERAL NOTES

1. GENERAL NOTES APPLY TO ALL

DRAWINGS

2. THE GENERAL CONTRACTOR SHALL

COORDINATE CUT-OUTS FOR

CASEWORK, MILLWORK, OR OTHER

EQUIPMENT AS REQUIRED.

3. ALL ASPECTS OF THE WORK AND ITEMS

NOT SPECIFICALLY MENTIONED, BUT

WHICH ARE NECESSARY TO MAKE A

COMPLETE WORKING INSTALLATION,

SHALL BE INCLUDED, AND INDICATED IN

THE CONTRACTORS BID.

4. NO ASBESTOS OR PCB CONTAINING

MATERIALS SHALL BE USED ON THIS

PROJECT.

5. THE GENERAL CONTRACTOR AND ALL

SUBCONTRACTORS ARE RESPONSIBLE

FOR PROPER REMOVAL AND DISPOSAL

OF ALL DEBRIS GENERATED BY

CONSTRUCTION OF THIS PROJECT. THE

REMOVAL AND DISPOSAL OF ALL

CONSTRUCTION DEBRIS SHALL BE IN

FULL COMPLIANCE WITH ALL FEDERAL,

STATE AND LOCAL REGULATIONS. THE

PREMISES SHALL BE KEPT CLEAN AND

FREE FROM ALL WASTE MATERIALS.

6. GENERAL CONTRACTOR SHALL

PROTECT NEW CONSTRUCTION FROM

DAMAGE BY ALL TRADES. ALL SUCH

DAMAGE CAUSED BY THE CONTRACTOR

DURING THE COURSE OF THIS WORK

SHALL BE REPAIRED OR REPLACED AT

THE CONTRACTORS EXPENSE.

7. CONTRACTOR IS RESPONSIBLE FOR

FIELD VERIFICATION OF ALL

DIMENSIONS AND FIELD CONDITIONS

PRIOR TO ORDERING OR INSTALLING

MATERIALS OR EQUIPMENT.

8. ALL PIPING AND CONDUITS SHALL BE

CONCEALED WITHIN WALLS,

UNDERGROUND, ABOVE CEILINGS OR IN

ARCHITECT APPROVED UTILITY SPACES

IN ALL CASES UNLESS SPECIFICALLY

NOTED OTHERWISE ON THE DRAWINGS.

EXPOSED ITEMS MUST BE LOCATED IN .

ALL EXPOSED ITEMS ARE TO BE

PAINTED TO MATCH THE ADJACENT

SURFACES UNLESS SCHEDULED FOR

AN ACCENT COLOR.

FINISH NOTES

KEY NOTES

DEMO KEY NOTES

AD.1

AD.2

AD.3

NEW FLOORING TO BE INSTALLED

NEW STAINLESS STEEL SIDE WALL

PANELS TO BE INSTALLED

NEW STAINLESS STEEL INTERIOR

CAB DOOR PANELS TO BE

INSTALLED

NEW ALUMINUM SILLS TO BE

INSTALLED

NEW STAINLESS STEEL CAB

INTERIOR CONTROL PANEL TO BE

INSTALLED

EXISTING EXTERIOR DOOR PANELS

TO REMAIN

NEW BLACK LAMINATE RECESSED

CEILING REVEAL TO BE INSTALLED

NEW STAINLESS STEEL CEILING

PANELS TO BE INSTALLED

NEW WHITE LAMINATE CEILING

SOFFIT TO BE INSTALLED

NEW SQUARE LED LIGHT FIXTURE

NEW BLACK LAMINATE RECESSED

CEILING REVEAL TO BE INSTALLED

EXISTING VINYL FLOORING TO BE

REMOVED

EXISTING WOOD SIDE WALL PANELS

TO BE REMOVED

EXISTING INTERIOR CAB DOORS

AND SILLS TO BE REMOVED

EXISTING CAB INTERIOR CONTROL

PANEL TO BE REMOVED

EXISTING LED DOWNLIGHT CEILING

PANELS TO BE REMOVED

AD.4

FLOORING

MFR: MILLIKEN

STYLE: CHARLOTTE

COLOR: CHT209

INSTALL PATTERN: BRICK PATTERN

CAB SIDE WALL PANELS + CEILING

PANELS

MFR: TBD

STYLE: STAINLESS STEEL

COLOR: TBD

CAB WALL/ CEILING REVEAL PANELS

MFR: WILSON ART

STYLE: BLACKBIRD

COLOR: 5024

INTERIOR CAB DOOR PANELS

MFR: TBD

STYLE: STAINLESS STEEL

COLOR: TBD

CAB SOFFIT PANELS

MFR: WILSON ART

STYLE: FROSTY WHITE

COLOR: 1573

CAB CEILING LIGHTS

MFR: MAN-D-TEC

STYLE: S^2 BEAM

COLOR: STAINLESS STEEL/ALUMINUM

CONTROL PANEL BUTTONS

MFR: INNOVATION

STYLE: BRUISER HALO SERIES

COLOR: PB-72, ILLUMINATION: GREEN

FLOOR/DIRECTION INDICATOR BUTTON

MFR: TBD

STYLE: TBD

COLOR: TBD

DIGITAL T.V. WAYFINDING PANEL

MFR: SAMSUNG

STYLE: Q60A QLED SMART TV

COLOR: BLACK

AD.5

PUBLIC LOBBY ENTRY

STAFF ENTRY

A.402 03

LEVEL 1

0"

NEW INDICATOR BUTTONS WALL FINISH TO

REMAIN

NEW CALL BUTTON

EXISTING DOOR FINISH TO

REMAIN

NEW CALL BUTTON

ERIC KLEINSTEUBER

FL LICENSE # AR93580

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

PA

R

C

EL

ID

6-

-2

9-

-0

0-

O ra ng e

C ou nt y

R eg io na l H is to ry

C en te r

E

AS

T

C

EN

TR

AL

B O

U

LE

VA

R

D O

R

LA

N D

O , F

L

El ev at or

M od er ni za tio n

ENLARGED

ELEVATIONS

210604 11/02/21

A.401 01

1/4" = 1'-0" 03FLOOR CUT FULL VIEW

1/4" = 1'-0" 04GROUND FLOOR LOBBY ELEVATION

1/4" = 1'-0" 05FLOOR 2 LOBBY ELEVATION

1/4" = 1'-0" 06FLOOR 3 LOBBY ELEVATION

1/4" = 1'-0" 07FLOOR 4 LOBBY ELEVATION

1/4" = 1'-0" 08FLOOR 5 LOBBY ELEVATION

1/4" = 1'-0" 09GROUND FLOOR LOBBY DEMO

1/4" = 1'-0" 10FLOOR 2 LOBBY DEMO

1/4" = 1'-0" 11FLOOR 3 LOBBY DEMO

1/4" = 1'-0" 12FLOOR 4 LOBBY DEMO

1/4" = 1'-0" 13FLOOR 5 LOBBY DEMO

0 2' 4' 8'

0 2' 4' 8'

0 2' 4' 8'

0 2' 4' 8'

0 2' 4' 8'

0 2' 4' 8'

0 2' 4' 8'

0 2' 4' 8'

0 2' 4' 8'

0 2' 4' 8'

NEW CONSTRUCTION

1/4" = 1'-0" 02INTERIOR CAB PLAN REFERENCE0 2' 4' 8'

0 2' 4' 8'

NOTES

DEMOLITION DRAWINGSDEMOLITION PHOTOS

# DATE DESCRIPTION

01 2021.11.02 PERMIT &

1/4" = 1'-0" 01GROUND FLOOR SERVICE SIDE ELEVATION0 2' 4' 8'

NEW STAINLESS

STEEL DOOR PANELS

NEW INDICATOR BUTTON

NEW STAINLESS

STEEL PANEL

NEW BUTTON ARRAY

SYSTEM

8'

/1 6"

F .V

NEW STAINLESS STEEL

WALL PANELS

NEW STAINLESS STEEL

HANDRAL

8' - 6" F.V.

2' - 8" 1 1/2" 2' - 8" 1 1/2" 2' - 8" 1 1/2"1 1/2"

EXISTING WALL PANEL

TO REMAIN

EXISTING WALL PANEL

TO REMAIN

NEW BLACK LAMINATE WALL

REVEAL PANELS

2'

5'

/4

1/

2"

5"

2"

2'

1/

2"

1/

2"

NEW STAINLESS STEEL

WALL PANELS

NEW STAINLESS STEEL HANDRAIL

2'

1/

2"NEW STAINLESS STEEL PANEL

(SIDE OF CONTROL PANEL)

NEW STAINLESS STEEL PANEL

(SIDE OF CONTROL PANEL)

NEW BLACK LAMINATE WALL REVEAL

PANELS

1 1/2" 2' - 8" 1 1/2" 2' - 8" 1 1/2" 2' - 8" 1 1/2"

NEW DIGITAL MONITOR (WALL

MOUNTED)

8' - 6" F.V.

5'

/4

NEW STAINLESS STEEL PANEL

(SIDE OF CONTROL PANEL)

1/

2"

1/ 2"

2"

2' - 4 1/2"

NEW STAINLESS

STEEL DOOR PANELS

NEW INDICATOR BUTTON

NEW STAINLESS

STEEL CONTROL WALL

PANEL

NEW BUTTON ARRAY

SYSTEM

8'

/1 6"

F .V

REMOVE DOOR PANELS

REMOVE INDICATOR BUTTON

REMOVE WALL

CONTROL PANEL

REMOVE BUTTON ARRAY

REMOVE WALL PANELS

REMOVE HANDRAIL

REMOVE EXISTING

CONTROL WALL

PANEL

8' - 6" F.V.

REMOVE EXISTING WALL

REVEAL PANELS

REMOVE

EXISTING

CONTROL

WALL PANEL

REMOVE WALL PANELS

REMOVE HANDRAIL

REMOVE EXISTING SIGN

8' - 6" F.V.

2'

1/

4" 5"

F .V

REMOVE EXISTING WALL

REVEAL PANELS

REMOVE DOOR PANELS

REMOVE INDICATOR BUTTON

REMOVE EXISTING

BUTTON ARRAY

SYSTEM

REMOVE EXISTING CONTROL

WALL PANEL

GENERAL NOTES

1. GENERAL NOTES APPLY TO ALL

DRAWINGS

2. THE GENERAL CONTRACTOR SHALL

COORDINATE CUT-OUTS FOR

CASEWORK, MILLWORK, OR OTHER

EQUIPMENT AS REQUIRED.

3. ALL ASPECTS OF THE WORK AND ITEMS

NOT SPECIFICALLY MENTIONED, BUT

WHICH ARE NECESSARY TO MAKE A

COMPLETE WORKING INSTALLATION,

SHALL BE INCLUDED, AND INDICATED IN

THE CONTRACTORS BID.

4. NO ASBESTOS OR PCB CONTAINING

MATERIALS SHALL BE USED ON THIS

PROJECT.

5. THE GENERAL CONTRACTOR AND ALL

SUBCONTRACTORS ARE RESPONSIBLE

FOR PROPER REMOVAL AND DISPOSAL

OF ALL DEBRIS GENERATED BY

CONSTRUCTION OF THIS PROJECT. THE

REMOVAL AND DISPOSAL OF ALL

CONSTRUCTION DEBRIS SHALL BE IN

FULL COMPLIANCE WITH ALL FEDERAL,

STATE AND LOCAL REGULATIONS. THE

PREMISES SHALL BE KEPT CLEAN AND

FREE FROM ALL WASTE MATERIALS.

6. GENERAL CONTRACTOR SHALL

PROTECT NEW CONSTRUCTION FROM

DAMAGE BY ALL TRADES. ALL SUCH

DAMAGE CAUSED BY THE CONTRACTOR

DURING THE COURSE OF THIS WORK

SHALL BE REPAIRED OR REPLACED AT

THE CONTRACTORS EXPENSE.

7. CONTRACTOR IS RESPONSIBLE FOR

FIELD VERIFICATION OF ALL

DIMENSIONS AND FIELD CONDITIONS

PRIOR TO ORDERING OR INSTALLING

MATERIALS OR EQUIPMENT.

8. ALL PIPING AND CONDUITS SHALL BE

CONCEALED WITHIN WALLS,

UNDERGROUND, ABOVE CEILINGS OR IN

ARCHITECT APPROVED UTILITY SPACES

IN ALL CASES UNLESS SPECIFICALLY

NOTED OTHERWISE ON THE DRAWINGS.

EXPOSED ITEMS MUST BE LOCATED IN .

ALL EXPOSED ITEMS ARE TO BE

PAINTED TO MATCH THE ADJACENT

SURFACES UNLESS SCHEDULED FOR

AN ACCENT COLOR.

FINISH NOTES

KEY NOTES

DEMO KEY NOTES

AD.1

AD.2

AD.3

NEW FLOORING TO BE INSTALLED

NEW STAINLESS STEEL SIDE WALL

PANELS TO BE INSTALLED

NEW STAINLESS STEEL INTERIOR

CAB DOOR PANELS TO BE

INSTALLED

NEW ALUMINUM SILLS TO BE

INSTALLED

NEW STAINLESS STEEL CAB

INTERIOR CONTROL PANEL TO BE

INSTALLED

EXISTING EXTERIOR DOOR PANELS

TO REMAIN

NEW BLACK LAMINATE RECESSED

CEILING REVEAL TO BE INSTALLED

NEW STAINLESS STEEL CEILING

PANELS TO BE INSTALLED

NEW WHITE LAMINATE CEILING

SOFFIT TO BE INSTALLED

NEW SQUARE LED LIGHT FIXTURE

NEW BLACK LAMINATE RECESSED

CEILING REVEAL TO BE INSTALLED

EXISTING VINYL FLOORING TO BE

REMOVED

EXISTING WOOD SIDE WALL PANELS

TO BE REMOVED

EXISTING INTERIOR CAB DOORS

AND SILLS TO BE REMOVED

EXISTING CAB INTERIOR CONTROL

PANEL TO BE REMOVED

EXISTING LED DOWNLIGHT CEILING

PANELS TO BE REMOVED

AD.4

FLOORING

MFR: MILLIKEN

STYLE: CHARLOTTE

COLOR: CHT209

INSTALL PATTERN: BRICK PATTERN

CAB SIDE WALL PANELS + CEILING

PANELS

MFR: TBD

STYLE: STAINLESS STEEL

COLOR: TBD

CAB WALL/ CEILING REVEAL PANELS

MFR: WILSON ART

STYLE: BLACKBIRD

COLOR: 5024

INTERIOR CAB DOOR PANELS

MFR: TBD

STYLE: STAINLESS STEEL

COLOR: TBD

CAB SOFFIT PANELS

MFR: WILSON ART

STYLE: FROSTY WHITE

COLOR: 1573

CAB CEILING LIGHTS

MFR: MAN-D-TEC

STYLE: S^2 BEAM

COLOR: STAINLESS STEEL/ALUMINUM

CONTROL PANEL BUTTONS

MFR: INNOVATION

STYLE: BRUISER HALO SERIES

COLOR: PB-72, ILLUMINATION: GREEN

FLOOR/DIRECTION INDICATOR BUTTON

MFR: TBD

STYLE: TBD

COLOR: TBD

DIGITAL T.V. WAYFINDING PANEL

MFR: SAMSUNG

STYLE: Q60A QLED SMART TV

COLOR: BLACK

AD.5

ERIC KLEINSTEUBER

FL LICENSE # AR93580

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

PA

R

C

EL

ID

6-

-2

9-

-0

0-

O ra ng e

C ou nt y

R eg io na l H is to ry

C en te r

E

AS

T

C

EN

TR

AL

B O

U

LE

VA

R

D O

R

LA

N D

O , F

L

El ev at or

M od er ni za tio n

ENLARGED

INTERIOR PLANS

AND ELEVATIONS

210604 11/02/21

A.402 01

1/2" = 1'-0" 04CAB INTERIOR SOUTH ELEVATION

1/2" = 1'-0" 03CAB INTERIOR EAST ELEVATION

1/2" = 1'-0" 02CAB INTERIOR WEST ELEVATION

1/2" = 1'-0" 01CAB INTERIOR NORTH ELEVATION

1/2" = 1'-0" 09CAB INTERIOR SOUTH DEMO ELEVATION

1/2" = 1'-0" 07CAB INTERIOR WEST DEMO ELEVATION

1/2" = 1'-0" 08CAB INTERIOR EAST DEMO ELEVATION

1/2" = 1'-0" 05CAB INTERIOR NORTH DEMO ELEVATION 0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4' NOTES

# DATE DESCRIPTION

01 2021.11.02 PERMIT &

Certificate of Frame: 5.0" x 8.0"L

Left to Right, Top to Bottom (Excluding Floor Buttons):

-Door Open Button, Door Hold Open Button, Door Close Button -Alarm Button, Emergency Stop (Keyswitch UTE) -Phone Button, Call Receved Light and Microphone

Left to Right, Top to Bottom:

-Key Card Access Reader -5th, 4th, 3rd, 2nd, 1R, and 1st Floors Buttons

- ADA Braille Tags: Fishtail

Fire Service Cabinet :

-Door Open, Door Close Buttons -Fire Service Keyswitch: Florida Phase II -Call Cancel Button -Fire Hat Jewel -Run/Stop Toggle Switch -Fire Service Instructions -Fireman's Phone Jack

Left to Right, Top to Bottom:

-Floor 1 Lock-Out Key Switch -Independent Service Key -Access Enable Key Switch -2-Speed Fan Key Switch -Fire Hat Jewel -Light Keyswitch

Top to Bottom:

-Engraving Detail

Top to Bottom:

-Position/Direction Indicator

Top to Bottom:

-Speaker

Top to Bottom:

-Emergency Light

FA

C

EP

LA

TE

8'

/1

6" F

.V

FACEPLATE

1' - 4 7/8" F.V.

1R

RUN

LIGHT ON, CALL PLACED

LIGHT FLASHING, HELP ON WAY

5"

8"

FIREFIGHTER'S OPERATION

(Certificate Frame)

" M

AX

A

D A

R

EQ

4'

0"

" A

D A

M

IN

R

EQ

2'

1/

Left to Right, Top to Bottom (Excluding Floor Buttons):

-Door Open Button, Extended Door Open Button, Door Close Button

-Alarm Button

Left to Right, Top to Bottom:

-5th, 4th, 3rd, 2nd, 1R, and 1st Floors Buttons -ADA Braille Tags: Fishtail

Top to Bottom:

-Position/Direction Indicator

FA

C

EP

LA

TE

8'

/1

6" F

.V

FACEPLATE

1' - 4 7/8" F.V.

1R

RUN

LIGHT ON, CALL PLACED

LIGHT FLASHING, HELP ON WAY

" M

AX

A

D A

R

EQ

4'

0"

" M

IN

A

D A

R

EQ

2'

1/

GENERAL NOTES

1. GENERAL NOTES APPLY TO ALL

DRAWINGS

2. THE GENERAL CONTRACTOR SHALL

COORDINATE CUT-OUTS FOR

CASEWORK, MILLWORK, OR OTHER

EQUIPMENT AS REQUIRED.

3. ALL ASPECTS OF THE WORK AND ITEMS

NOT SPECIFICALLY MENTIONED, BUT

WHICH ARE NECESSARY TO MAKE A

COMPLETE WORKING INSTALLATION,

SHALL BE INCLUDED, AND INDICATED IN

THE CONTRACTORS BID.

4. NO ASBESTOS OR PCB CONTAINING

MATERIALS SHALL BE USED ON THIS

PROJECT.

5. THE GENERAL CONTRACTOR AND ALL

SUBCONTRACTORS ARE RESPONSIBLE

FOR PROPER REMOVAL AND DISPOSAL

OF ALL DEBRIS GENERATED BY

CONSTRUCTION OF THIS PROJECT. THE

REMOVAL AND DISPOSAL OF ALL

CONSTRUCTION DEBRIS SHALL BE IN

FULL COMPLIANCE WITH ALL FEDERAL,

STATE AND LOCAL REGULATIONS. THE

PREMISES SHALL BE KEPT CLEAN AND

FREE FROM ALL WASTE MATERIALS.

6. GENERAL CONTRACTOR SHALL

PROTECT NEW CONSTRUCTION FROM

DAMAGE BY ALL TRADES. ALL SUCH

DAMAGE CAUSED BY THE CONTRACTOR

DURING THE COURSE OF THIS WORK

SHALL BE REPAIRED OR REPLACED AT

THE CONTRACTORS EXPENSE.

7. CONTRACTOR IS RESPONSIBLE FOR

FIELD VERIFICATION OF ALL

DIMENSIONS AND FIELD CONDITIONS

PRIOR TO ORDERING OR INSTALLING

MATERIALS OR EQUIPMENT.

8. ALL PIPING AND CONDUITS SHALL BE

CONCEALED WITHIN WALLS,

UNDERGROUND, ABOVE CEILINGS OR IN

ARCHITECT APPROVED UTILITY SPACES

IN ALL CASES UNLESS SPECIFICALLY

NOTED OTHERWISE ON THE DRAWINGS.

EXPOSED ITEMS MUST BE LOCATED IN .

ALL EXPOSED ITEMS ARE TO BE

PAINTED TO MATCH THE ADJACENT

SURFACES UNLESS SCHEDULED FOR

AN ACCENT COLOR.

FINISH NOTES

KEY NOTES

DEMO KEY NOTES

AD.1

AD.2

AD.3

NEW FLOORING TO BE INSTALLED

NEW STAINLESS STEEL SIDE WALL

PANELS TO BE INSTALLED

NEW STAINLESS STEEL INTERIOR

CAB DOOR PANELS TO BE

INSTALLED

NEW ALUMINUM SILLS TO BE

INSTALLED

NEW STAINLESS STEEL CAB

INTERIOR CONTROL PANEL TO BE

INSTALLED

EXISTING EXTERIOR DOOR PANELS

TO REMAIN

NEW BLACK LAMINATE RECESSED

CEILING REVEAL TO BE INSTALLED

NEW STAINLESS STEEL CEILING

PANELS TO BE INSTALLED

NEW WHITE LAMINATE CEILING

SOFFIT TO BE INSTALLED

NEW SQUARE LED LIGHT FIXTURE

NEW BLACK LAMINATE RECESSED

CEILING REVEAL TO BE INSTALLED

EXISTING VINYL FLOORING TO BE

REMOVED

EXISTING WOOD SIDE WALL PANELS

TO BE REMOVED

EXISTING INTERIOR CAB DOORS

AND SILLS TO BE REMOVED

EXISTING CAB INTERIOR CONTROL

PANEL TO BE REMOVED

EXISTING LED DOWNLIGHT CEILING

PANELS TO BE REMOVED

AD.4

FLOORING

MFR: MILLIKEN

STYLE: CHARLOTTE

COLOR: CHT209

INSTALL PATTERN: BRICK PATTERN

CAB SIDE WALL PANELS + CEILING

PANELS

MFR: TBD

STYLE: STAINLESS STEEL

COLOR: TBD

CAB WALL/ CEILING REVEAL PANELS

MFR: WILSON ART

STYLE: BLACKBIRD

COLOR: 5024

INTERIOR CAB DOOR PANELS

MFR: TBD

STYLE: STAINLESS STEEL

COLOR: TBD

CAB SOFFIT PANELS

MFR: WILSON ART

STYLE: FROSTY WHITE

COLOR: 1573

CAB CEILING LIGHTS

MFR: MAN-D-TEC

STYLE: S^2 BEAM

COLOR: STAINLESS STEEL/ALUMINUM

CONTROL PANEL BUTTONS

MFR: INNOVATION

STYLE: BRUISER HALO SERIES

COLOR: PB-72, ILLUMINATION: GREEN

FLOOR/DIRECTION INDICATOR BUTTON

MFR: TBD

STYLE: TBD

COLOR: TBD

DIGITAL T.V. WAYFINDING PANEL

MFR: SAMSUNG

STYLE: Q60A QLED SMART TV

COLOR: BLACK

AD.5

4 2 42

8' - 6" F.V.

22 2

2 2

8' - 6" F.V.

22 2

FL

O

O R

T O

B O

TT

O

M E

D G

E 5'

6"

FL

O

O R

T O

T O

P

ED

G E

6'

3/

1 3/4" 2' - 4 1/2" 1 3/4"

2'

7/

INSTALL NEW

32" SAMSUNG

CLASS Q60A

QLED 4K

SMART T.V.

BO

TT

O M

O F

SS

P

AN

EL

T O

T V

ED

G

E 2'

1/ 2"

2" 2" 3"

3"

(BEHIND

MONITOR)

CUT IN PANEL

FOR

POWER/DATA/W

ALL MOUNT

ACCESS

1'

/1 6"

ONE FOR ALL WM

4219 WALL MOUNT

TO BE INSTALLED

CUT-OUT IN WALL

PANEL FOR POWER

CHORD ACESS/WALL

MOUNT

7/

8"

7/

8"

F.V.

WALL MOUNT MAX DISTANCE

9 9/16"

PANEL CUT WIDTH

2' - 0 1/2"

/8

NEW DATA DUPLEX

TO BE INSTALLED

NEW POWER

DUPLEX TO BE

INSTALLED

BO

TT

O M

O F

SS

P

AN

EL

T O

C U

T

ED

G E

2'

1/

2"

BO

TT

O M

O F

SS

P

AN

EL

T O

C U

T

TO

P

ED

G E

3'

5/

D

IS

PL

AY

H

EI

G H

T 1'

/1

6"

NEW STAINLESS STEEL PANEL

CAB SHELL WALL

SHELL TO DISPLAY EDGE

2 3/16"

NEW 32" SAMSUNG CLASS Q60A QLED 4K SMART

T.V

VESA FLAT FIXED TV WALL MOUNT

MIN. 25mm TV DISTANCE

25mm MIN

VE

SA

T V

W

AL

L M

O U

N T

H

EI

G H

T

7/ 8"

PA

N

EL

C

U T

H

EI

G H

T

/8

4" MAX

ERIC KLEINSTEUBER

FL LICENSE # AR93580

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

PA

R

C

EL

ID

6-

-2

9-

-0

0-

O ra ng e

C ou nt y

R eg io na l H is to ry

C en te r

E

AS

T

C

EN

TR

AL

B O

U

LE

VA

R

D O

R

LA

N D

O , F

L

El ev at or

M od er ni za tio n

ADDITIONAL

ELEVATIONS

210604 11/02/21

A.403 01

1 1/2" = 1'-0" 06MAIN CAR OPERATING PANEL

1 1/2" = 1'-0" 03SECONDARY CAR OPERATING PANEL0 1' 2' 0 1' 2'

1/2" = 1'-0" 05CAB INTERIOR SOUTH ELEVATION FINISHES

1/2" = 1'-0" 02CAB INTERIOR NORTH ELEVATION FINISHES

1/2" = 1'-0" 04CAB INTERIOR WEST ELEVATION FINISHES

1/2" = 1'-0" 01CAB INTERIOR EAST ELEVATION FINISHES NOTES

# DATE DESCRIPTION

01 2021.11.02 PERMIT &

CONSTRUCT.

1 1/2" = 1'-0" 09DIGITAL PANEL DETAIL

1 1/2" = 1'-0" 08DIGITAL PANEL DETAIL 2

6" = 1'-0" 07DIGITAL PANEL SECTION DETAIL 0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1' 2' 4'

0 1" 2" 4" 6"

0 1' 2' 0 1' 2'

GENERAL NOTES

1. GENERAL NOTES APPLY TO ALL

DRAWINGS

2. THE GENERAL CONTRACTOR SHALL

COORDINATE CUT-OUTS FOR

CASEWORK, MILLWORK, OR OTHER

EQUIPMENT AS REQUIRED.

3. ALL ASPECTS OF THE WORK AND ITEMS

NOT SPECIFICALLY MENTIONED, BUT

WHICH ARE NECESSARY TO MAKE A

COMPLETE WORKING INSTALLATION,

SHALL BE INCLUDED, AND INDICATED IN

THE CONTRACTORS BID.

4. NO ASBESTOS OR PCB CONTAINING

MATERIALS SHALL BE USED ON THIS

PROJECT.

5. THE GENERAL CONTRACTOR AND ALL

SUBCONTRACTORS ARE RESPONSIBLE

FOR PROPER REMOVAL AND DISPOSAL

OF ALL DEBRIS GENERATED BY

CONSTRUCTION OF THIS PROJECT. THE

REMOVAL AND DISPOSAL OF ALL

CONSTRUCTION DEBRIS SHALL BE IN

FULL COMPLIANCE WITH ALL FEDERAL,

STATE AND LOCAL REGULATIONS. THE

PREMISES SHALL BE KEPT CLEAN AND

FREE FROM ALL WASTE MATERIALS.

6. GENERAL CONTRACTOR SHALL

PROTECT NEW CONSTRUCTION FROM

DAMAGE BY ALL TRADES. ALL SUCH

DAMAGE CAUSED BY THE CONTRACTOR

DURING THE COURSE OF THIS WORK

SHALL BE REPAIRED OR REPLACED AT

THE CONTRACTORS EXPENSE.

7. CONTRACTOR IS RESPONSIBLE FOR

FIELD VERIFICATION OF ALL

DIMENSIONS AND FIELD CONDITIONS

PRIOR TO ORDERING OR INSTALLING

MATERIALS OR EQUIPMENT.

8. ALL PIPING AND CONDUITS SHALL BE

CONCEALED WITHIN WALLS,

UNDERGROUND, ABOVE CEILINGS OR IN

ARCHITECT APPROVED UTILITY SPACES

IN ALL CASES UNLESS SPECIFICALLY

NOTED OTHERWISE ON THE DRAWINGS.

EXPOSED ITEMS MUST BE LOCATED IN .

ALL EXPOSED ITEMS ARE TO BE

PAINTED TO MATCH THE ADJACENT

SURFACES UNLESS SCHEDULED FOR

AN ACCENT COLOR.

FINISH NOTES

KEY NOTES

DEMO KEY NOTES

AD.1

AD.2

AD.3

NEW FLOORING TO BE INSTALLED

NEW STAINLESS STEEL SIDE WALL

PANELS TO BE INSTALLED

NEW STAINLESS STEEL INTERIOR

CAB DOOR PANELS TO BE

INSTALLED

NEW ALUMINUM SILLS TO BE

INSTALLED

NEW STAINLESS STEEL CAB

INTERIOR CONTROL PANEL TO BE

INSTALLED

EXISTING EXTERIOR DOOR PANELS

TO REMAIN

NEW BLACK LAMINATE RECESSED

CEILING REVEAL TO BE INSTALLED

NEW STAINLESS STEEL CEILING

PANELS TO BE INSTALLED

NEW WHITE LAMINATE CEILING

SOFFIT TO BE INSTALLED

NEW SQUARE LED LIGHT FIXTURE

NEW BLACK LAMINATE RECESSED

CEILING REVEAL TO BE INSTALLED

EXISTING VINYL FLOORING TO BE

REMOVED

EXISTING WOOD SIDE WALL PANELS

TO BE REMOVED

EXISTING INTERIOR CAB DOORS

AND SILLS TO BE REMOVED

EXISTING CAB INTERIOR CONTROL

PANEL TO BE REMOVED

EXISTING LED DOWNLIGHT CEILING

PANELS TO BE REMOVED

AD.4

FLOORING

MFR: MILLIKEN

STYLE: CHARLOTTE

COLOR: CHT209

INSTALL PATTERN: BRICK PATTERN

CAB SIDE WALL PANELS + CEILING

PANELS

MFR: TBD

STYLE: STAINLESS STEEL

COLOR: TBD

CAB WALL/ CEILING REVEAL PANELS

MFR: WILSON ART

STYLE: BLACKBIRD

COLOR: 5024

INTERIOR CAB DOOR PANELS

MFR: TBD

STYLE: STAINLESS STEEL

COLOR: TBD

CAB SOFFIT PANELS

MFR: WILSON ART

STYLE: FROSTY WHITE

COLOR: 1573

CAB CEILING LIGHTS

MFR: MAN-D-TEC

STYLE: S^2 BEAM

COLOR: STAINLESS STEEL/ALUMINUM

CONTROL PANEL BUTTONS

MFR: INNOVATION

STYLE: BRUISER HALO SERIES

COLOR: PB-72, ILLUMINATION: GREEN

FLOOR/DIRECTION INDICATOR BUTTON

MFR: TBD

STYLE: TBD

COLOR: TBD

DIGITAL T.V. WAYFINDING PANEL

MFR: SAMSUNG

STYLE: Q60A QLED SMART TV

COLOR: BLACK

AD.5

OPENING

4' - 5 11/16" F.V.

OPENING

4' - 5 11/16" F.V.

PLATFORM WIDTH

5' - 10 3/4" F.V.

8'

6"

1'

1/

2"

PLATFORM WIDTH

5' - 10 3/4" F.V.

8'

6" 1'

4"

HOISTWAY CLEAR WIDTH

9' - 2 5/16" F.V.

HOISTWAY CLEAR WIDTH

10' - 2 5/16"

DIVIDER BEAM

8"

3/

4"

1/

2"

8'

3"

WALL BARRIER TO WALL BARRIER

5' - 10 3/4"

WALL BARRIER TO WALL BARRIER

5' - 10 3/4"

8'

6"

2 21

22 1

2 4

2 4

WALL BARRIER TO WALL BARRIER

5' - 10 3/4"

WALL BARRIER TO WALL BARRIER

5' - 10 3/4"

8'

6"

5 5

5 5

8'

6"

TYP.

TYP.

TYP. TYP.

2"

1/

2"

1/ 2"

2 1/4"

1/

4"

1/4"

8'

1/

2"

1/

4"

NEW STAINLESS

STEEL HANDRAIL

5"

2'

1/

2"

1/ 2" 2"

1/4"

2 1/4"

3 1/4"

1/

4"

1 13/16"

/1 6"

1/ 8"

1/

2"

1/

8"

1/ 8"

1 3/4"

1' - 5 1/4"

1"

1' - 5 1/4"

1"

1' - 5 1/4"

1 3/4"

WALL TO WALL BARRIER

5' - 10 3/4"

7 3/4" 7 3/4"

1 13/16"

/1 6"

ERIC KLEINSTEUBER

FL LICENSE # AR93580

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

PA

R

C

EL

ID

6-

-2

9-

-0

0-

O ra ng e

C ou nt y

R eg io na l H is to ry

C en te r

E

AS

T

C

EN

TR

AL

B O

U

LE

VA

R

D O

R

LA

N D

O , F

L

El ev at or

M od er ni za tio n

SPECIALTY

SECTIONS AND

DETAILS

210604 11/02/21

A.404 01

1/2" = 1'-0" 08INTERIOR CAB PLAN FINISHES

1/2" = 1'-0" 07INTERIOR CAB REFLECTED CEILING PLAN FINISHES

0 1' 2' 4'

0 1' 2' 4'

1 1/2" = 1'-0" 04HANDRAIL DETAIL ELEVATION

1" = 1'-0" 06HANDRAIL DETAIL PLAN

0 1' 2'

1 1/2" = 1'-0" 03HANDRAIL SECTION DETAIL0 1/2' 1' 2' 0 1' 2'

12" = 1'-0" 02S BEAM LIGHTING PLAN

12" = 1'-0" 05S BEAM LIGHTING ELEVATION

NOTE: IF SOFFIT IS NOT PERMISSABLE TO

CONSTRUCT BECAUSE OF ESCAPE HATCH

LOCATION, PLEASE REVERT TO LED

DOWNLIGHT CEILING OPTION

NOTES

# DATE DESCRIPTION

01 2021.11.02 PERMIT &

CONSTRUCT.

1 1/2" = 1'-0" 01SOFFIT/CEILING PLAN DETAIL0 1' 2'

0 1" 2" 3"0 1" 2" 3"

S

VFD

TS

S

APPROVED EQUAL

COLUMBIA

CSL-4040

HUBBELL

TRP1-12L-20-4K7-3-UNV-DB

DAY-BRITE

FSSEZ-4-40L-840-UNV

VISIONAIRE

PGAS-1-T3-32LC-5-4K-UNV-WM

LITHONIA

CLX-L48-4000LM-SEF-RDL-MVOLT-GZ10-

40K-80CRI

COLUMBIA

CVT4-LS40 (SET TO 4620 LUMEN)

LITHONIA

XVML L48 3500LM MVOLT 40K 80CRI

LJ 20W

LITHONIA

WST LED P1 40K VW MVOLT

W

CI

DT

D1

C

D2

P

LT

R9

TC

PC

LVS

LC

SPD

40W120/277V LED

LED SURFACE MOUNT LENSED STRIPLIGHT,

MINIMUM 4000 LUMEN OUTPUT, 0-10 VOLT

DIMMING, DAMP LOCATION RATED

DN

G

LB

ST

DB

EWC

WP

WP

PP

PD

C

C

PB

J

J

C

C

TV

TV

P

S

S

S

S

SM

KS

aS

PS

2S

4S 3S

3a

3K

EXP

SL

WP

DETAIL NUMBER

SHEET NUMBER TO WHERE DETAIL IS REFERENCED

XX.XX

XX

SCALE:

DETAIL TITLE REFERENCE

DETAIL NUMBER

SHEET NUMBER WHERE DETAIL IS REFERENCED

ADDITIONAL SHEET REFERENCES

SINGLE RECEPTACLE

JUNCTION BOX

DUPLEX RECEPTACLE

DISCONNECT SWITCH

DOOR BELL PUSH BUTTON

EQUIPMENT CONNECTION

SPECIAL PURPOSE RECEPTACLE

DOUBLE DUPLEX RECEPTACLE

MOTOR STARTER

SHUNT TRIP. MTD. AT 6'-5" AFF/AFG TO TOP OF ENCLOSURE

PHOTOCELL

DOOR BELL

TIMECLOCK

TRANSFORMER

DUPLEX RECEPTACLE, GROUND FAULT, ABOVE COUNTER

DUPLEX RECEPTACLE, GROUND FAULT

SINGLE 250V NON-LOCKING TYPE RECEPTACLE

ABOVE COUNTER DUPLEX RECEPTACLE

DUPLEX RECEPTACLE, HALF SWITCHED

MOTOR

120/208V PANELBOARD, SURFACE MOUNT

277/480V PANELBOARD, SURFACE MOUNT

POWER/DATA POLE

PULL BOX

CEILING MOUNTED RECEPTACLE

RECESSED FLOOR RECEPTACLE

FLOOR MOUNTED JUNCTION BOX

120/208V PANELBOARD, RECESSED

277/480V PANELBOARD, RECESSED

FEEDER OR BRANCH CIRCUIT CONCEALED IN WALL,

CEILING OR FLOOR

STARTER/DISCONNECT SWITCH

GENERATOR

CLOCK

LOCKBOX

DUPLEX RECEPTACLE, GROUND FAULT

WITH CAST ALUMINUM PADLOCKABLE ( 1_

" HASP)

WEATHERPROOF "IN USE" COVER. TAYMAC MX3200 OR EQUAL

DUPLEX RECEPTACLE, GROUND FAULT

LOCATE WITHIN ELECTRIC WATER COOLER PER

MANUFACTURER'S INSTRUCTIONS

DUPLEX RECEPTACLE FOR COMPUTER WORKSTATION

DUPLEX RECEPTACLE FOR TV LOCATED AT 18"AFF. LOCATE IN

COMMON BOX WITH CCTV

DUPLEX RECEPTACLE FOR TV LOCATED AT 84" AFF UNLESS

NOTED OTHERWISE.

AIR TERMINAL (ALUMINUM CLASS 1 MIN).

ROOFTOP MAIN CONDUCTOR, RUN EXPOSED ACROSS

ROOF.

DOWN CONDUCTOR, RUN CONCEALED IN STRUCTURE -

COPPER CLASS 1

COPPER-CLAD DRIVEN GROUND ROD AND TEST WELL.

SEE SPECIFICATIONS.

BOLTED 3-WAY SPLICE

BOLTED 4-WAY SPLICE

GROUND BUS BAR

GROUND ROD WITH TEST INSPECTION WELL. SEE

SPECIFICATIONS.

PIR-WALL SWITCH DECORATOR MOTION SENSOR, 120/277 VAC,

800/1200W. WATTSTOPPER PW-100 OR EQUAL.

DUAL ULTRASONIC/PIR-WALL SWITCH DECORATOR MOTION

SENSOR, 120/277VAC, 800/1200W. WATTSTOPPER DW-100 OR EQUAL.

*DUAL ULTRASONIC/PIR-CEILING MOUNT SENSOR, 24 VDC/VAC,

35mA. WATTSTOPPER DT-305 OR EQUAL.

*DUAL ULTRASONIC/PIR-WALL MOUNT SENSOR, 24 VAC/VDC, 35mA.

WATTSTOPPER DT-205 OR EQUAL.

POWER PACK 120/277 VAC; 20 AMPS, 225mA SECONDARY.

WATTSTOPPER BZ-250 OR EQUAL.

*PIR-WALL MOUNT SENSOR, LOW TEMP, 24 VDC/AC, 20mA.

WATTSTOPPER CB-100 OR EQUAL.

*PIR-CEILING MOUNT SENSOR 24 VDC/VAC, 11mA, WATTSTOPPER

CI-205 OR EQUAL.

QUAD RECEPTACLE, GROUND FAULT WITH CAST ALUMINUM

PADLOCKABLE (1_

" HASP) WEATHERPROOF "IN USE" COVER.

TAYMAC MX 6200 OR EQUAL.

TRACK FIXTURE

CEILING MOUNTED RECESSED, DOWN LIGHT

EMERGENCY LIGHT FIXTURE

2'x4' FIXTURE

1'x4' FIXTURE

2'x2' FIXTURE

SURFACE MOUNTED LIGHTING FIXTURE

2'x4' FIXTURE, BATTERY/EMERGENCY

2'x2' FIXTURE, BATTERY/EMERGENCY

1'x4' FIXTURE, BATTERY/EMERGENCY

FLOOD LIGHT FIXTURE

BOLLARD OR PENDANT LIGHT FIXTURE

AMPERES

ABOVE FINISHED FLOOR

ABOVE FINISHED GRADE

BELOW FINISHED GRADE

ELECTRIC UNIT HEATER

ELECTRIC WATER COOLER

ELECTRIC WATER HEATER

ELECTRICAL METALLIC TUBING

BELOW FINISHED CEILING

EWH

FLUOR

FA

EXIST

EXH

EQUIP

EWC

EUH

EMT

EF

FLUORESCENT

FIRE ALARM

EXHAUST

EXISTING

EXHAUST FAN

EQUIPMENT

CLG

DISC

DWG

EA

CU

CL

CAB

CKT

BFG

CEILING

CENTERLINE

DISCONNECT(ING)

DRAWING(S)

EACH

COPPER

CABINET

CIRCUIT

CONDUIT

AFG

BFC

A

AFF

NATIONAL ELECTRICAL CODE

POLYVINYL CHLORIDE

UNLESS OTHERWISE NOTED

XFMR

V

WP

VA

TEL

UON

TRANSFORMER

TELEPHONE

VOLT-AMPERES

WEATHER PROOF

VOLTS

PVC

PNL

REC

NEC

MTR

MTG

MTD

MISC

MIN

RECEPTACLE

PANEL

MINIMUM

MISCELLANEOUS

MOUNTED

MOUNTING

MOTOR

HEATING/VENTILATING/

KILO-VOLTS-AMPERES

KILO-WATT-HOURS

MOTOR CONTROL CENTERMCC

MH

MFR

MAX

LTG

kVA kWH kW kV

JB

METAL HALIDE

LIGHTING

MANUFACTURER

MAXIMUM

JUNCTION BOX

KILO-VOLTS

KILO-WATTS

HVAC

HV

INC

HP HORSEPOWER

HIGH VOLTAGE

INCANDESCENT

FLA FULL LOAD AMPERES

ABOVE FINISHED CEILINGAFC

W WATTS

TYP TYPICAL

GFCI GROUND FAULT CIRCUIT

INTERRUPTER

CURRENT TRANSFORMERSCT's

KILO-VOLTS-AMPERES REACTIVEkVAR

RGS RIGID GALVANIZED STEEL

C m METER mm MILLIMETER

AIC AMPERES INTERUPTING

CAPACITY

MCB MAIN CIRCUIT BREAKER

MCP MOTOR CIRCUIT PROTECTOR

AIR CONDITIONING

HAND-OFF-AUTOMATIC

HIGH INTENSITY DISCHARGE

HIGH PRESSURE SODIUM

HID

HOA

HPS

GND

HGT

GROUND

HEIGHT

GFP GROUND FAULT PROTECTION

VFD VARIABLE FREQUENCY DRIVE

AMERICAN WIRE GAUGEAWG

PULL STATION INSIDEPSI

EXP EXPLOSION PROOFAUDIO ENHANCEMENTAE

1R1-1,3,5

1M1-1:3:5

1R1-1

1M1-1:3

1R1-1,3

4' WALL MOUNT FIXTURE

4' WALL MOUNT FIXTURE, EMERGENCY

CEILING MOUNTED RECESSED, EMERGENCY DOWN LIGHT

BOLLARD OR PENDANT LUMINAIRE, EMERGENCY

WALL MOUNTED SCONCE FIXTURE, BATTERY/EMERGENCY

POLE MOUNTED LUMINAIRE

SINGLE POLE MOUNT LUMINAIRE-RECTANGLES INDICATE

NUMBER OF FIXTURES

HOMERUN CONSISTING OF ONE SINGLE-PHASE, 1-POLE CIRCUIT,

SEE SPECIFICATIONS AND/OR FEEDER SCHEDULES FOR WIRE SIZES.

PANELBOARD AND CIRCUIT DESIGNATION ARE INDICATED.

HOMERUN CONSISTING OF THREE SINGLE-PHASE CIRCUITS: SEE

SPECIFICATIONS AND/OR FEEDER SCHEDULES FOR WIRE SIZES.

PANELBOARD AND CIRCUIT DESIGNATIONS ARE INDICATED.

HOMERUN CONSISTING OF ONE THREE-PHASE CIRCUITS: SEE

SPECIFICATIONS AND/OR FEEDER SCHEDULES FOR WIRE SIZES.

PANELBOARD AND CIRCUIT DESIGNATIONS ARE INDICATED.

HOMERUN CONSISTING OF ONE SINGLE-PHASE, 2-P0LE CIRCUIT:

SEE SPECIFICATIONS AND/OR FEEDER SCHEDULES FOR WIRE

SIZES. PANELBOARD AND CIRCUIT DESIGNATIONS ARE INDICATED.

HOMERUN CONSISTING OF TWO SINGLE-PHASE CIRCUITS: SEE

SPECIFICATIONS AND/OR FEEDER SCHEDULES FOR WIRE SIZES.

PANELBOARD AND CIRCUIT DESIGNATION ARE INDICATED.

CEILING MOUNTED RECESSED, WALL WASHER (ARROW

INDICATES DIRECTION OF WASH)

SINGLE FACE EXIT LIGHT FIXTURE ARROW INDICATES

DIRECTION OF EGRESS

DOUBLE FACE EXIT LIGHT FIXTURE ARROW INDICATES

DIRECTION OF EGRESS

POLE MOUNTED SITE LIGHTING FIXTURE RECTANGLES

INDICATE NUMBER OF FIXTURES

QUAD RECEPTACLE, GROUND FAULT

POWER POLE ALUMINUMAL

T

SURGE PROTECTION DEVICE, SEE SPECIFICATIONS.

SPD SURGE PROTECTION DEVICE

ECB ENCLOSED CIRCUIT BREAKER

MMS MANUAL MOTOR STARTER SWITCH

*ULTRASONIC-CEILING CORRIDOR MOTION SENSOR, 24 VDC/VAC,

40mA. WATTSTOPPER WT-2250 OR EQUAL.

NOTIFICATION APPLIANCE CIRCUITNAC

SWITCH, 1 POLE, LETTER INDICATES SWITCHLEG CONTROLLED.

SWITCH, KEYSWITCH

SWITCH

SWITCH, 2 POLE

SWITCH, 3-WAY

SWITCH, 4-WAY

SWITCH - PILOT LIGHT

MOTOR RATED SWITCH

SWITCH, 3-WAY, LETTER INDICATES SWITCHLEG CONTROLLED

SWITCH, KEYSWITCH, 3-WAY

NIGHT LIGHT, UNSWITCHEDNL

*FOR LOW VOLTAGE OCCUPANCY SENSORS, PROVIDE POWER

PACK(S) 120/277 VAC; 20 AMPS, 225mA SECONDARY AS NEEDED FOR

ZONE/AREA CONTROL. WATTSTOPPER BZ-250 OR EQUAL.

SWITCH - LINE VOLTAGE TIMER, 120/277 VAC. WATTSTOPPER

TS-400 OR EQUAL.

DUAL ULTRASONIC/PIR-DUAL RELAY WALL SWITCH DECORATOR

MOTION SENSOR, 120/277VAC, 800/1200W. WATTSTOPPER DW-200

OR EQUAL.

SWITCH, EXPLOSION PROOF

QUAD RECEPTACLE FOR COMPUTER WORKSTATION

4' STRIP FIXTURE

4' STRIP FIXTURE, BATTERY/EMERGENCY

4' STRIP FIXTURE, WALL MOUNTED

4' STRIP FIXTURE, WALL MOUNTED,

BATTERY/EMERGENCY

VARIABLE FREQUENCY DRIVE

UL 924 LISTED FAILSAFE EMERGENCY SWITCHING RELAY, LVS EPC-A

OR EQUAL. LOWER CASE LETTER NEXT TO DEVICE INDICATES

SWITCHLEG CONTROLLED.

SWITCH, LOW VOLTAGE MOMENTARY

SWITCH, WEATHERPROOF

LIGHTING CONTACTOR

LIGHTING FIXTURE SCHEDULE

TYPE DESCRIPTION DESIGN SELECTION APPROVED SUBSTITUTE APPROVED SUBSTITUTE VOLTS LAMPS/FIXTURE MAX INPUT WATTAGE

EXTERIOR WALL SCONCE, LED, MINIMUM 4200

LUMEN OUTPUT, UL LISTED WET LOCATION,

BRONZE COLOR/FINISH.

120/277V LED INCLUDED

FN

NOTES

1. ALL LED FIXTURES SHALL HAVE MINIMUM 80 CRI.

2. ALL LED FIXTURES SHALL HAVE CORRELATED COLOR TEMPERATURE OF 4000/4100K, UNLESS OTHERWISE NOTED.

3. FIXTURES WITH ELECTRONIC BALLAST SHALL HAVE 20% MAXIMUM HARMONIC DISTORTION.

4. FINAL FIXTURE FINISHES SHALL BE SELECTED DURING SUBMITTAL PROCESS BY ARCHITECT FROM EXTENDED STANDARD COLOR CHART FOR EACH FIXTURE.

5. CONFIRM COLOR OF EXTERIOR FIXTURES LAMP SOURCE PRIOR TO PURCHASE, MATCH EXISTING BUILDING'S FIXTURES.

6. ALL FIXTURES SHALL BE LABELED WITH MAXIMUM ALLOWABLE WATTAGE. MAXIMUM IS THE WATTAGE OF LAMP AS SHOWN IN SCHEDULE.

7. ALL FIXTURES, WHETHER STANDARD OR NOT, REQUIRE LISTING BY A NATIONALLY RECOGNIZED TESTING LABORATORY.

8. ALL FIXTURE NOTED AS EMERGENCY FIXTURES SHALL SUPPLY A MINIMUM OF 90MIN BACK-UP BATTERY POWER

9. ALL LED FIXTURES SHALL HAVE INTERNAL DISCONNECTING MEANS ON LINE SIDE INCLUDING GROUNDED CONDUCTOR PER NEC 410.130(G). UL INTERNAL DISCONNECT

TO BE INSTALLED BY FACTORY AND TO BE INCLUDED IN ALL SUBMITTALS.

10. WHEN FIXTURE MODEL DIFFERS FROM FIXTURE DESCRIPTION, THEN THE FIXTURE DESCRIPTION SHALL GOVERN.

FH1

LED 4'-0" FIXTURE, ENCLOSED, 3500 LUMEN

MINIMUM, IP66 OR IP67 RATED, GASKETED WET

LOCATION, TAMPER PROOF LATCHES, SURFACE

MOUNTING BRACKETS

120/277V LED 35 W

LIGHTING FIXTURES

POWER DEVICES

POWER DISTRIBUTION

LIGHTING CONTROL DEVICES

LIGHTNING PROTECTION

MISCELLANEOUS SYMBOL LEGEND

ABBREVIATIONS

SWITCHES

SGM

ENGINEERING

935 Lake Baldwin Lane.

Orlando, FL. 32814 Tel: 407-767-5188 Fax: 704-767-5772

CA-00006208

Copyright © 2020 SGM Engineering, Inc.

www.sgmengineering.com

SGM #: 2020-084

STATE OF

ENEIL

ADIROL

F

No. 70700

R O

FES

OI NA

S

L E N

N

G I

E E

C S

R

P

J U S T I N

L OW E MUN

D E L L

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

JUSTIN L. MUNDELL - FL70700

P A

R C

E L I

D

-2

-2

-6

-0

-0

01 2021.11.02 PERMIT &

CONSTRUCT.

O R

A N

G E

C O

U N

T Y

R H

C E

L E

V A

T O

R S

ELECTRICAL

SYMBOLS

LEGEND

2106.04

11/02/21

E.001

E

C

E N

T R

A L

B L V

D O

R L

A N

D O

F

L

# DATE DESCRIPTION

PIT LTGPIT LTG

1 1

1 1

SGM

ENGINEERING

935 Lake Baldwin Lane.

Orlando, FL. 32814 Tel: 407-767-5188 Fax: 704-767-5772

CA-00006208

Copyright © 2020 SGM Engineering, Inc.

www.sgmengineering.com

SGM #: 2020-084

STATE OF

ENEIL

ADIROL

F

No. 70700

R O

FES

OI NA

S

L E N

N

G I

E E

C S

R

P

J U S T I N

L OW E MUN

D E L L

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

JUSTIN L. MUNDELL - FL70700

P A

R C

E L I

-2

-2

-6

-0

-0

01 2021.11.02 PERMIT &

CONSTRUCT.

O R

A N

G E

C O

U N

T Y

R H

C E

L E

V A

T O

R S

ELECTRICAL

DEMO LIGHTING

PLANS

2106.04

11/02/21

ED.201

E

C

E N

T R

A L

B L V

D O

R L

A N

D O

F

L

1/4" = 1'-0"ED.201

ELECTRICAL DEMO CEILING PLAN - LEVEL

1/4" = 1'-0"ED.201

ELECTRICAL DEMO CEILING PLAN - LEVEL

1/4" = 1'-0"ED.201

ELECTRICAL DEMO CEILING PLAN - LEVEL

1/4" = 1'-0"ED.201

ELECTRICAL DEMO CEILING PLAN - LEVEL

1/4" = 1'-0"ED.201

ELECTRICAL DEMO CEILING PLAN - LEVEL

1/4" = 1'-0"ED.201

ELECTRICAL DEMO CEILING PLAN - ROOF

MACHINE ROOM

a. REFER TO SYMBOL LEGEND NOTES ON SHEET E.001.

b. REFER TO BOOK SPECIFICATIONS.

c. ITEMS SHOWN DARK ARE EXISTING TO BE REMOVED.

d. ITEMS SHOWN SCREENED ARE EXISTING TO REMAIN.

GENERAL NOTES:

PLAN KEYNOTES:

1 REMOVE FIXTURE. CONDUIT AND WIRING TO BE REUSED.

2 REMOVE CURRENT ROOM LIGHTING CONTROLS.

3 FIXTURES ARE TO REMAIN ON THEIR CURRENT CONTROLS.

WP

WP

WP

ELEVATOR #2

ELEVATOR #1

ELEVATOR CAB LTG #2

ELEVATOR CAB LTG #11

SGM

ENGINEERING

935 Lake Baldwin Lane.

Orlando, FL. 32814 Tel: 407-767-5188 Fax: 704-767-5772

CA-00006208

Copyright © 2020 SGM Engineering, Inc.

www.sgmengineering.com

SGM #: 2020-084

STATE OF

ENEIL

ADIROL

F

No. 70700

R O

FES

OI NA

S

L E N

N

G I

E E

C S

R

P

J U S T I N

L OW E MUN

D E L L

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

JUSTIN L. MUNDELL - FL70700

P A

R C

E L I

-2

-2

-6

-0

-0

01 2021.11.02 PERMIT &

CONSTRUCT.

O R

A N

G E

C O

U N

T Y

R H

C E

L E

V A

T O

R S

ELECTRICAL

DEMO POWER

PLANS

2106.04

11/02/21

ED.301

E

C

E N

T R

A L

B L V

D O

R L

A N

D O

F

L

1/4" = 1'-0"ED.301

1 ELECTRICAL DEMO FLOOR PLAN - LEVEL 1

1/4" = 1'-0"ED.301

2 ELECTRICAL DEMO FLOOR PLAN - LEVEL 2

1/4" = 1'-0"ED.301

3 ELECTRICAL DEMO FLOOR PLAN - LEVEL 3

1/4" = 1'-0"ED.301

4 ELECTRICAL DEMO FLOOR PLAN - LEVEL 4

1/4" = 1'-0"ED.301

5 ELECTRICAL DEMO FLOOR PLAN - LEVEL 5

1/4" = 1'-0"ED.301

ELECTRICAL DEMO FLOOR PLAN - ROOF

MACHINE ROOM

a. REFER TO SYMBOL LEGEND ON SHEET E.001.

b. REFER TO BOOK SPECIFICATIONS.

c. CONTRACTOR SHALL PERFORM CIRCUIT TRACE ON ALL

BRANCH CIRCUITS IN PANEL BEING WORKED UPON AND

PROVIDE AN UPDATED TYPEWRITTEN PANEL SCHEDULE

IDENTIFYING CIRCUITS FED AND LOCATION AND/OR ROOM

NUMBER.

d. CONTRACTOR TO CHECK PHASE ROTATION PRIOR TO

DISCONNECTION AND AFTER RECONNECTION OF POWER.

e. ITEMS SHOWN DARK ARE EXISTING TO BE REMOVED.

f. ITEMS SHOWN SCREENED ARE EXISTING TO REMAIN.

GENERAL NOTES:

PLAN KEYNOTES:

1 DISCONNECT CONNECTION FROM EQUIPMENT TO BE REMOVED.

T

PIT LTGPIT LTG

FH1

FH1 FH1

FH1

LJ

LJ

LJ

LJ

FN FN

FN FN

3 3

ELEVATORS

SGM

ENGINEERING

935 Lake Baldwin Lane.

Orlando, FL. 32814 Tel: 407-767-5188 Fax: 704-767-5772

CA-00006208

Copyright © 2020 SGM Engineering, Inc.

www.sgmengineering.com

SGM #: 2020-084

STATE OF

ENEIL

ADIROL

F

No. 70700

R O

FES

OI NA

S

L E N

N

G I

E E

C S

R

P

J U S T I N

L OW E MUN

D E L L

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

JUSTIN L. MUNDELL - FL70700

P A

R C

E L I

-2

-2

-6

-0

-0

01 2021.11.02 PERMIT &

CONSTRUCT.

O R

A N

G E

C O

U N

T Y

R H

C E

L E

V A

T O

R S

ELECTRICAL

LIGHTING PLANS

2106.04

11/02/21

E.201

E

C

E N

T R

A L

B L V

D O

R L

A N

D O

F

L

1/4" = 1'-0"E.201

1 ELECTRICAL CEILING PLAN - LEVEL 1

1/4" = 1'-0"E.201

2 ELECTRICAL CEILING PLAN - LEVEL 2

1/4" = 1'-0"E.201

3 ELECTRICAL CEILING PLAN - LEVEL 3

1/4" = 1'-0"E.201

4 ELECTRICAL CEILING PLAN - LEVEL 4

1/4" = 1'-0"E.201

5 ELECTRICAL CEILING PLAN - LEVEL 5

1/4" = 1'-0"E.201

ELECTRICAL CEILING PLAN - ROOF

MACHINE ROOM

GENERAL NOTES:

a. REFER TO SYMBOL LEGEND NOTES ON SHEET E-001.

b. REFER TO BOOK SPECIFICATIONS.

c. REFER TO ARCHITECTURAL INTERIOR ELEVATIONS TO

COORDINATE EXACT PLACEMENT OF ALL DEVICES,

EQUIPMENT, FIXTURES, SWITCHES, AND OUTLETS.

d. CONNECT ALL EMERGENCY BALLAST, EMERGENCY BATTERY

UNITS AND EXITS AHEAD OF ALL SWITCHING TO LOCAL

LIGHTING CIRCUIT.

e. ALL MOTION SENSOR DEVICES SHALL BE CONNECTED

AHEAD OF ALL LOCAL SWITCHES.

f. MOTION SENSOR LOCATIONS ARE SHOWN FOR GENERAL

INFORMATION. LOCATE IN ACCORDANCE WITH

MANUFACTURERS INSTRUCTIONS. LOCATE MOTION

SENSORS A MINIMUM OF 4' AWAY FROM ANY A/C DIFFUSER.

g. ITEMS SHOWN DARK ARE NEW TO BE PROVIDED.

h. ITEMS SHOWN SCREENED ARE EXISTING TO REMAIN.

KEYPLAN

1" = 40'-0"

PLAN KEYNOTES:

1 COORDINATE PLACEMENT OF ELEVATOR PIT LIGHTING FIXTURES,

SWITCH AND RECEPTACLE WITH ELEVATOR EQUIPMENT. SWITCH

SHALL BE LOCATED ADJACENT TO THE PIT LADDER.

2 PROVIDE CONNECTION FROM PIT LIGHTING FIXTURES TO GFCI

RECEPTACLE IN PIT. COORDINATE EXACT LOCATION WITH

ELEVATOR INSTALLER. FIXTURES SHALL NOT BE CONNECTED TO

LOAD SIDE OF GFCI RECEPTACLE.

3 PROVIDE NEW LIGHTING FIXTURE. CONNECT TO EXISTING CIRCUIT.

M M

UP

C C

C C

C

C

SUMP PUMPSUMP PUMP

WP

WP

EL1A-35 EL1A-37

5 5

WP

ELEVATOR #2

ELEVATOR #1

ELEVATOR CAB LTG #2

ELEVATOR CAB LTG #1

SUMP PUMP

CONTROLLER

ELEVATORS

1ST

FLOOR

MAIN

ELEC RM

SGM

ENGINEERING

935 Lake Baldwin Lane.

Orlando, FL. 32814 Tel: 407-767-5188 Fax: 704-767-5772

CA-00006208

Copyright © 2020 SGM Engineering, Inc.

www.sgmengineering.com

SGM #: 2020-084

STATE OF

ENEIL

ADIROL

F

No. 70700

R O

FES

OI NA

S

L E N

N

G I

E E

C S

R

P

J U S T I N

L OW E MUN

D E L L

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

JUSTIN L. MUNDELL - FL70700

P A

R C

E L I

-2

-2

-6

-0

-0

01 2021.11.02 PERMIT &

CONSTRUCT.

O R

A N

G E

C O

U N

T Y

R H

C E

L E

V A

T O

R S

ELECTRICAL

POWER PLANS

2106.04

11/02/21

E.301

E

C

E N

T R

A L

B L V

D O

R L

A N

D O

F

L

1/4" = 1'-0"E.301

1 ELECTRICAL FLOOR PLAN - LEVEL 11/4" = 1'-0"E.301

2 ELECTRICAL FLOOR PLAN - LEVEL 2

1/4" = 1'-0"E.301

3 ELECTRICAL FLOOR PLAN - LEVEL 3

1/4" = 1'-0"E.301

4 ELECTRICAL FLOOR PLAN - LEVEL 4

1/4" = 1'-0"E.301

5 ELECTRICAL FLOOR PLAN - LEVEL 51/4" = 1'-0"E.301

ELECTRICAL FLOOR PLAN - ROOF MACHINE

ROOM

a. REFER TO SYMBOL LEGEND ON SHEET E.001.

b. REFER TO BOOK SPECIFICATIONS.

c. REFER TO ARCHITECTURAL INTERIOR ELEVATIONS TO

COORDINATE EXACT PLACEMENT OF ALL DEVICES,

EQUIPMENT, FIXTURES, SWITCHES AND OUTLETS.

d. REFER TO EQUIPMENT SCHEDULES ON DRAWINGS E.701FOR

DISCONNECT, CONDUIT AND WIRE SIZES.

e. ALL FEEDERS ARE TO HAVE LESS THAN 2% TOTAL VOLTAGE

DROP AND ALL BRANCH CIRCUITS SHALL HAVE LESS THAN

3% VOLTAGE DROP.

f. IF CIRCUITS ARE COMBINED AND RUN AS MULTI-WIRE

BRANCH CIRCUITS SHARING A COMMON NEUTRAL, THEN

EACH UNGROUNDED CONDUCTOR MUST BE DISCONNECTED

SIMULTANEOUSLY BY A COMMON TRIP CIRCUIT BREAKER.

CONTRACTOR MAY, AT THEIR OPTION, PROVIDE EITHER

COMMON TRIP MULTI-POLE CIRCUIT BREAKERS OR UTILIZE

MANUFACTURERS LISTED HANDLE TIES IN ORDER TO

PROVIDE THE SIMULTANEOUS TRIP. THESE DEVICES ARE

NOT SHOWN IN THE PANEL SCHEDULES AND MUST BE

PROVIDED BY THIS SCOPE OF WORK. NO MORE THAN 3

CIRCUITS MAY BE COMBINED IN A SINGLE RACEWAY

WITHOUT PRIOR APPROVAL BY THE ENGINEER.

g. CONTRACTOR SHALL PERFORM CIRCUIT TRACE ON ALL

BRANCH CIRCUITS IN PANEL BEING WORKED UPON AND

PROVIDE AN UPDATED TYPEWRITTEN PANEL SCHEDULE

IDENTIFYING CIRCUITS FED AND LOCATION AND/OR ROOM

NUMBER.

h. CONTRACTOR TO SEGREGATE ALL GROUNDS AND

NEUTRALS ONTO THE CORRECT BUS.

i. CONTRACTOR TO CONFIRM THAT THERE IS A GROUND

CONDUCTOR FOR EACH LOAD OR THAT THE CONDUIT PATH

GROUND IS CONTINUOUS FOR EACH LOAD.

j. CONTRACTOR TO CHECK PHASE ROTATION PRIOR TO

DISCONNECTION AND AFTER RECONNECTION OF POWER.

k. CONTRACTOR TO IDENTIFY CONDUITS EXITING PANEL WITH

CIRCUIT NUMBER INFORMATION.

l. ENSURE ALL WIRES ARE TAGGED PER IDENTIFICATION

SPECIFICATION.

m. ITEMS SHOWN DARK ARE NEW TO BE PROVIDED.

n. ITEMS SHOWN SCREENED ARE EXISTING TO REMAIN.

GENERAL NOTES:

KEYPLAN

1" = 40'-0"

PLAN KEYNOTES:

1 PROVIDE SERVICE DISCONNECT AND CONNECTION TO EQUIPMENT.

SEE EQUIPMENT FEEDER SCHEDULE FOR CONDUIT, WIRE, AND

DISCONNECT SIZES.

2 PROVIDE SUMP PUMP CONTROLLER AND CONNECTION TO

ELEVATOR PIT SUMP PUMP.

3 ELEVATOR CAB LIGHTS. PROVIDE 250V, 30A, 2P, NEMA-1

DISCONNECT SWITCH WITH CLASS RK5 FUSES AND REJECTION

CLIPS.

4 ELEVATOR DISCONNECT SWITCH. PROVIDE 480V, 100A, 3P, NEMA-1

DISCONNECT SWITCH WITH CLASS RK5 FUSES AND REJECTION

CLIPS. RECONNECT NEW ELEVATOR TO EXISTING FIRE ALARM

SEQUENCE.

5 PROGRAM ACCESS CONTROL CARD READER TO ALLOW

PASSTHROUGH OF ELEVATOR TO BACK OF HOUSE.

SGM

ENGINEERING

935 Lake Baldwin Lane.

Orlando, FL. 32814 Tel: 407-767-5188 Fax: 704-767-5772

CA-00006208

Copyright © 2020 SGM Engineering, Inc.

www.sgmengineering.com

SGM #: 2020-084

STATE OF

ENEIL

ADIROL

F

No. 70700

R O

FES

OI NA

S

L E N

N

G I

E E

C S

R

P

J U S T I N

L OW E MUN

D E L L

839 N MAGNOLIA AVE

ORLANDO, FL 32803

#AR93580

KMFARCHITECTS.COM

407.298.1988

ISSUE

PROJECT #

DATE:

SHEET NUMBER ISSUE

JUSTIN L. MUNDELL - FL70700

P A

R C

E L I

-2

-2

-6

-0

-0

01 2021.11.02 PERMIT &

CONSTRUCT.

O R

A N

G E

C O

U N

T Y

R H

C E

L E

V A

T O

R S

ELECTRICAL

ONE-LINE

DIAGRAMS

2106.04

11/02/21

E.501

E

C

E N

T R

A L

B L V

D O

R L

A N

D O

F

L

SCOPE OF WORK

a. PROVIDE NEW 480V, 3P, 60A CIRCUIT BREAKER IN EXISITNG

DISTRIBUTION PANEL EM5A. PROVIDE NEW SURGE

PROTECTION DEVICE.

GENERAL NOTES:

EQUIPMENT FEEDER SCHEDULE: * WIRE SIZES ARE BASED ON NFPA 70 TABLE 310.15(B)(16) 60 DEGREE CU COLUMN FOR SIZES OF 100A OR LESS, ALL OTHERS BASED ON 75 DEGREE COLUMN.

**DISTANCE SHOWN FOR VOLTAGE DROP CALCULATION ONLY. ACTUAL DISTANCE MAY VARY DEPENDENT ON ROUTING.

EQUIPMENT VOLTS PH NEUT MOTOR ADDITIONAL HEAT MISC TOTAL MIN PNL. DISCONNECT STARTER WIRE NEUT GND # CONDUIT APPROX VOLT

DESCRIPTION Y/N (LARGEST) MOTORS STRIPS AMPS AMPS CKT A C.B. SIZE OCPD SIZE NEMA PER WIRE WIRE OF SIZE DIST.** DROP NOTES

H.P. FLA H.P. FLA KW AMPS MCA SIZE TYPE PHASE* RUNS FT VD%

EXISTING ELEVATOR #1 480 3 Y 40.00 52.00 52.0 65.0 100 100 #2 #2 #8 1 2" 100 0.38% (a)

EXISTING ELEVATOR #2 480 3 Y 40.00 52.00 52.0 65.0 100 100 #2 #2 #8 1 2" 100 0.38% (a)

SUMP PUMP #1 120 1 Y 0.50 9.80 9.8 12.3 15 MMS NF 3R #10 #10 #10 1 3/4" 120 2.35%

SUMP PUMP #2 120 1 Y 0.50 9.80 9.8 12.3 15 MMS NF 3R #10 #10 #10 1 3/4" 120 2.35%

GENERAL NOTES: NOTES:

(1) - PROVIDE DISC. SW. AT ALL PIECES OF EQUIPMENT NOT WITHIN SIGHT OF THE OVERCURRENT PROTECTIVE DEVICE. (a) REUSE EXISTING CONDUIT AND WIRING FROM EXISTING PANEL

(2) - FUSES SHOWN FOR REFERENCE ONLY, PROVIDE FUSES AS RECOMMENDED BY EQUIP. MANUF. TO EXISTING DISCONNECT SWITCH. REMOVE AND REPLACE

(3) - PROVIDE NEMA OUTDOOR RATED ENCLOSURES FOR ALL DISC. SWS MOUNTED OUTDOORS. EXISTING DISCONNECT SWITCH, CONDUIT, AND WIRING FROM

(4) - COORDINATE STARTER TYPE WITH MECHANICAL EQUIPMENT. ELEVATOR EQUIPMENT TO BE REPLACED.

(5) - COORDINATE ALL OVERCURRENT PROTECTIVE DEVICES WITH THE ACTUAL EQUIPMENT BEING SUPPLIED. NOTIFY THE ENGINEER

IF DESCREPINCIES ARE FOUND.

(6) - DISCONNECTS BETWEENS MOTORS AND VFC'S SHALL BE PROVIDED WITH AN AUXILARY CONTACT AND

WIRED TO THE E-STOP OF THE VFD.

GENERATOR BATTERY CHARGER E 0.50 20 1

2 30

1.50 E

GENERATOR JACKET WATER HEATER

GENERATOR CONTROL PANEL E 0.50 20 1 1.50 E

RECEPT TICKET RM 107 R 0.36 20 1 1 20 0.60 R RECEPT TTB, IDC RM G100

RECEPT ELEVATOR PIT LTG R 0.50 20 1 1 20 0.60 R RECEPT TTB, IDC RM G100

RECEPT SECURITY TM 108 R 0.50 20 1 1 20 0.10 E ELECTRIC DOOR STRIKE RM 105

RECEPT SECURITY TM 108 R 0.50 20 1 1 20 S SPARE

RECEPT SECURITY TM 108 R 0.50 20 1 1 20 S SPARE

RECEPT SECURITY TM 108 R 0.50 20 1 1 20 S SPARE

RECEPT SECURITY TM 108 R 0.50 20 1 1 20 S SPARE

FACP/VOICE EVAC E 1.20 20 1 1 20 0.20 E FAN F-3, FAN F-5, FANF-21 (1)

SPARE S 20 1 1 20 0.10 E FAN F-1 (1/10HP)

DDC PANEL/PREACTION SYSTEM E 0.50 20 1 1 20 0.20 E EXTERIOR SECURITY CAMERA (1)

SPARE S 20 1 1 20 E DDC PANEL RM M100A

SPARE S 20 1 1 20 S SPARE

SPARE S 20 1 1 20 S SPARE

SPARE S 20 1 1 20 S SPARE

SPARE S 20 1 1 SPACE

1 SPACE

1 SPACE

SPACE 1 1 SPACE

SPACE 1 1…