21009 Bid Set - Stamped Drawings.pdf
PDF 42 MB Posted
- Attached to
- HEMLOCK FILTRATION PLANT HVAC UPGRADES
- Solicitation number
- C07230
- Issued by
- Jefferson County, New York
About this file
These documents are architectural and electrical engineering drawings for the Hemlock Filtration Plant HVAC Upgrades project located in Hemlock, New York, prepared by Architectura PC for the City of Rochester. The project involves comprehensive upgrades to the HVAC systems and electrical infrastructure of the second-floor laboratory space, including replacement of roof-mounted equipment such as chillers, fume hoods, fan coil units, exhaust fans, and a make-up air unit. The project will also include replacing existing lighting fixtures with LED alternatives. The project is estimated at $1,164,656 and will be executed through three separate lump sum contracts: General Construction, Mechanical Contractor, and Electrical Contractor.
The contract includes specific requirements such as an incentive program for employing qualified City residents, apprenticeship program participation, MWBE (Minority and Women-owned Business Enterprise) goals, and workforce requirements. The project is subject to New York State Wicks Law and will utilize bid documents available on BidNet. Bidders can obtain hard copies of documentation for a $60 specification deposit and $10 mailing fee from the City of Rochester's Bureau of Purchasing. The drawings detail extensive electrical and mechanical modifications, including new panelboards, variable frequency motor controllers, exhaust fan reconfigurations, and comprehensive lighting control systems with specifications for LED fixtures, vacancy sensors, and dimming capabilities.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A-101
A-101
# DESCRIPTION DATE
REVISIONS
C
IT
Y O
F R
O C
H
ES
TE
R
H
EM
LO
C
K
FI
LT
R
AT
IO
N P
LA
N
T
R
IX
H
IL
L R
O
AD
, H
EM
LO
C
K, N
Y
19606.05
KEY PLAN
DATE:
PROJECT #:
DRAWN BY:
CHECKED BY:
SCALE:
VERIFY SCALE
BAR IS ONE (1) INCH LONG
ON ORIGINAL DRAWING:
IF BAR IS NOT ONE (1) INCH LONG,
ADJUST SCALE ACCORDINGLY
0 1
H
VA
C U
PG
R
AD
ES
, N O
.:2
N
VAI/SBT
SBT
1/8" = 1'-0"
A-101
EXISTING, DEMO &
NEW UPPER LEVEL
PLAN & INTERIORS
Our lines. Your space.www.architecturapc.com
17 PITKIN STREET, SUITE 100
ROCHESTER, NEW YORK 14607 P: 585-442-8550
C O
N
TR
AC
T
D O
C U
M
EN
TS
03/10/2025
REG. EXP.: OCTOBER 31, 2026
CERTIFICATE NO. 2525243
# DESCRIPTION DATE
REVISIONS
C O
N
TR
AC
T
D O
C U
M
EN
TS
C
IT
Y O
F R
O C
H
ES
TE
R
H
EM
LO
C
K
FI
LT
R
AT
IO
N P
LA
N
T
R
IX
H
IL
L R
O
AD
, H
EM
LO
C
K, N
Y
03/10/2025
19606.05
KEY PLAN
DATE:
PROJECT #:
DRAWN BY:
CHECKED BY:
SCALE:
VERIFY SCALE
BAR IS ONE (1) INCH LONG
ON ORIGINAL DRAWING:
IF BAR IS NOT ONE (1) INCH LONG,
ADJUST SCALE ACCORDINGLY
0 1
H
VA
C U
PG
R
AD
ES
, N O
.:2
N
VAI/SBT
SBT
1/8" = 1'-0"
A-102
EXISTING & DEMO
ROOF PLAN
Our lines. Your space.www.architecturapc.com
17 PITKIN STREET, SUITE 100
ROCHESTER, NEW YORK 14607 P: 585-442-8550
# DESCRIPTION DATE
REVISIONS
C
IT
Y O
F R
O C
H
ES
TE
R
H
EM
LO
C
K
FI
LT
R
AT
IO
N P
LA
N
T
R
IX
H
IL
L R
O
AD
, H
EM
LO
C
K, N
Y
19606.05
KEY PLAN
DATE:
PROJECT #:
DRAWN BY:
CHECKED BY:
SCALE:
VERIFY SCALE
BAR IS ONE (1) INCH LONG
ON ORIGINAL DRAWING:
IF BAR IS NOT ONE (1) INCH LONG,
ADJUST SCALE ACCORDINGLY
0 1
H
VA
C U
PG
R
AD
ES
, N O
.:2
N
VAI/SBT
SBT
1/8" = 1'-0"
A-103
ROOF PLAN AND
DETAILS
Our lines. Your space.www.architecturapc.com
17 PITKIN STREET, SUITE 100
ROCHESTER, NEW YORK 14607 P: 585-442-8550
C O
N
TR
AC
T
D O
C U
M
EN
TS
03/10/2025
# DESCRIPTION DATE
REVISIONS
C
IT
Y O
F R
O C
H
ES
TE
R
H
EM
LO
C
K
FI
LT
R
AT
IO
N P
LA
N
T
R
IX
H
IL
L R
O
AD
, H
EM
LO
C
K, N
Y
19606.05
KEY PLAN
DATE:
PROJECT #:
DRAWN BY:
CHECKED BY:
SCALE:
VERIFY SCALE
BAR IS ONE (1) INCH LONG
ON ORIGINAL DRAWING:
IF BAR IS NOT ONE (1) INCH LONG,
ADJUST SCALE ACCORDINGLY
0 1
H
VA
C U
PG
R
AD
ES
, N O
.:2
N
VAI/SBT
SBT
1/8" = 1'-0"
A-104
EXISTING, DEMO &
NEW SECOND FLR.
REFLECTED CEILING
PLAN
Our lines. Your space.www.architecturapc.com
17 PITKIN STREET, SUITE 100
ROCHESTER, NEW YORK 14607 P: 585-442-8550
C O
N
TR
AC
T
D O
C U
M
EN
TS
03/10/2025
# DESCRIPTION DATE
REVISIONS
C
IT
Y O
F R
O C
H
ES
TE
R
H
EM
LO
C
K
FI
LT
R
AT
IO
N P
LA
N
T
R
IX
H
IL
L R
O
AD
, H
EM
LO
C
K, N
Y
19606.05
KEY PLAN
DATE:
PROJECT #:
DRAWN BY:
CHECKED BY:
SCALE:
VERIFY SCALE
BAR IS ONE (1) INCH LONG
ON ORIGINAL DRAWING:
IF BAR IS NOT ONE (1) INCH LONG,
ADJUST SCALE ACCORDINGLY
0 1
H
VA
C U
PG
R
AD
ES
, N O
.:2
N
VAI/SBT
SBT
1/8" = 1'-0"
A-105
TEMPORARY
PROTECTION PLAN
AND DETAILS
Our lines. Your space.www.architecturapc.com
17 PITKIN STREET, SUITE 100
ROCHESTER, NEW YORK 14607 P: 585-442-8550
C O
N
TR
AC
T
D O
C U
M
EN
TS
03/10/2025
FIRE ALARM AUDIO/VISUAL INDICATING DEVICE -
MOUNTING HEIGHT AS PER NFPA 72 WITH INTENSITY AS INDICATED
FIRE ALARM VISUAL INDICATING DEVICE -
MOUNTING HEIGHT AS PER NFPA 72 WITH INTENSITY AS INDICATED
SMOKE DETECTOR
HEAT DETECTOR
MANUAL PULL STATION - 42" AFF TO CENTER OF HANDLE
FIRE ALARM CONTROL PANEL - 6' AFF TO TOP OF BOX
ADDRESSABLE INTERFACE MODULE
REMOTE TEST STATION
DUCT DETECTOR - DEVICE BY ELECTRICAL CONTRACTOR
MAGNETIC DOOR HOLD
DEVICE DESIGNATIONS:
# = INDICATES FIRE ALARM INTENSITY
E = ELEVATOR RECALL CONTROLS
DOUBLE DUPLEX RECEPTACLE - NEMA 5-20R - WALL MOUNTED - FLUSH
SPECIAL PURPOSE - SUBSCRIPT INDICATES NEMA TYPE -
WALL MOUNTED - FLUSH
NOTE: WALL MOUNTED DEVICES SHALL BE 18" AFF TO CENTER OF BOX, UNO.
SYMBOL DESIGNATIONS:
AC - MOUNT 6" ABOVE SINK OR COUNTERTOP TO BOTTOM OF BOX
CD - CORD DROP
CTL - CONTROLLED RECEPTACLE
F - FLOOR MOUNTED
GF - GROUND FAULT CIRCUIT INTERRUPTER
H - MOUNT HORIZONTALLY 6" ABOVE SINK OR COUNTERTOP TO BOTTOM OF BOX
IG - ISOLATED GROUND
R - REFRIGERATOR, MOUNT 42" AFF.
SP - SURGE PROTECTED
TS - TAMPER RESISTANT
USB - USB CHARGER
WP = WEATHER RESISTANT GROUND FAULT CIRCUIT INTERRUPTER WITH WEATHERPROOF
WHILE-IN-USE COVER
# - CIRCUIT NUMBER
COMBINATION STARTER/DISCONNECT -
5' AFF TO TOP OF BOX
JUNCTION BOX - WALL OR CEILING
JUNCTION BOX - RECESSED IN FLOOR
DRY TYPE TRANSFORMER - SIZE AS NOTED
DISCONNECT SWITCH - NON FUSED
5' AFF TO TOP OF BOX
DISCONNECT SWITCH - FUSED
5' AFF TO TOP OF BOX
MOTOR STARTER
EXISTING PANELBOARD - FLUSH MOUNTED
EXISTING PANELBOARD - SURFACE MOUNTED
PANELBOARD - FLUSH MOUNTED
PANELBOARD - SURFACE MOUNTED
CONTROL PANEL - FLUSH MOUNTED
CONTROL PANEL - SURFACE MOUNTED
HOMERUN TO PANELBOARD
EQUIPMENT ON SAME CIRCUIT BUT SEPARATELY CONTROLLED
PRIMARY ELECTRIC SERVICE
SECONDARY ELECTRIC CIRCUIT
P
S
VARIABLE FREQUENCY MOTOR CONTROLLER
EQUIPMENT CONNECTION FLEX CONDUIT
SINGLE POLE - WALL MOUNTED - FLUSH
NOTE: WALL MOUNTED SWITCHES SHALL BE 46" AFF TO CENTER OF DEVICE
SWITCH DESIGNATIONS:
3 - MULTI-SWITCH (3-WAY)
D - 0-10V DIMMER SWITCH
VS - VACANCY SENSOR
CEILING MOUNTED SPEAKER
NOTE: WALL MOUNTED DEVICES SHALL BE 18" AFF TO CENTER OF BOX, UNO
DEVICE DESIGNATIONS:
AC - MOUNT 6" ABOVE COUNTER TOP TO BOTTOM OF BOX
F - FLOOR MOUNTED
H - MOUNTED HORIZONTALY 6" ABOVE COUNTER TOP TO BOTTOM OF BOX
W - WALL MOUNTED, 48" AFF TO CENTER
# - NUMBER OF JACKS
FIRE ALARM
RECEPTACLESEQUIPMENT
DISTRIBUTION
SWITCHES
TECHNOLOGY
DUPLEX RECEPTACLE - NEMA 5-20R - WALL MOUNTED - FLUSH
1. CONTRACTORS ARE URGED TO INSPECT THE SITE BEFORE SUBMITTING A BID PROPOSAL TO
ENSURE KNOWLEDGE OF PROJECT REQUIREMENTS AND SITE CONDITIONS. IF NO CLARIFICATION IS REQUESTED, IT WILL BE CONSIDERED THAT THE CONTRACTORS ARE IN FULL UNDERSTANDING
OF PROJECT REQUIREMENTS.
2. PROVIDE LABOR, SUPERVISION, EQUIPMENT, MATERIALS, AND SERVICES REQUIRED FOR THE
COMPLETE INSTALLATION OF THIS WORK IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE,
AND LOCAL CODES, AUTHORITIES HAVING JURISDICTION, AND STANDARDS INCLUDING BUT NOT
LIMITED TO, ASHRAE, IBC, NEC, AND NFPA.
3. NOTHING CONTAINED IN THE SPECIFICATIONS OR SHOWN ON THE DRAWINGS SHALL BE
CONSTRUED TO BE IN CONFLICT WITH ANY STATE OR LOCAL CODES, ORDINANCES OR
REGULATIONS.
4. THE USE OF THE WORD "PROVIDE" SHALL MEAN TO FURNISH, INSTALL AND CONNECT, READY TO
USE.
5. THE USE OF THE WORD "FURNISH" SHALL MEAN TO PROCURE AND DELIVER TO THE SITE.
6. THE USE OF THE WORD "INSTALL" SHALL MEAN TO PHYSICALLY PLACE INTO SERVICE AND
CONNECT, READY TO USE.
7. EQUIPMENT AND MATERIALS SHALL BE INSTALLED BY SKILLED TRADESMEN, FAMILIAR WITH THE COMPONENTS TO BE INSTALLED, AND IN ACCORDANCE WITH BEST PRACTICES OF THE INDUSTRY.
8. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL
OFFSETS, FITTINGS, AND ACCESSORIES THAT MAY BE REQUIRED. THIS CONTRACTOR SHALL
CAREFULLY EXAMINE THE ARCHITECTURAL, STRUCTURAL, HEATING, VENTILATING AND
AIR-CONDITIONING, ELECTRICAL, PLUMBING, AND OTHER PROJECT DOCUMENTS AS MAY BE
NECESSARY FOR PROPER OPERATION OR INSTALLATION AND SHALL PROVIDE OFFSETS, FITTINGS, AND ACCESSORIES TO MEET PROJECT CONDITIONS.
9. DISCREPANCIES BETWEEN DRAWINGS OR BETWEEN DRAWINGS AND SPECIFICATIONS SHALL BE
REPORTED TO PROFESSIONAL IN WRITING. OBTAIN WRITTEN INSTRUCTIONS FROM
PROFESSIONAL AS TO THE MANNER IN WHICH TO PROCEED. NO DEPARTURES FROM THE
PROJECT DOCUMENTS SHALL BE MADE WITHOUT PRIOR WRITTEN ACCEPTANCE BY THE
PROFESSIONAL.
10. DIMENSIONS, CLEARANCES, AND LOCATIONS OF EQUIPMENT AND MATERIALS SHALL BE FIELD
VERIFIED PRIOR TO ORDERING, PROCURING AND FURNISHING SAME.
11. NO EXTRA COMPENSATION OR CHARGES WILL BE ACCEPTED DUE TO DIFFERENCES BETWEEN THE
ACTUAL MEASUREMENTS AND THOSE INDICATED ON THE PLAN. THOROUGHLY COORDINATE
WORK WITH SITE CONDITIONS AND OTHER TRADES, DETERMINE EXACT ROUTE AND LOCATION OF
EACH DUCT, PIPE, CONDUIT, ETC. BEFORE FABRICATION AND INSTALLATION.
12. INSTALL WORK SUBSTANTIALLY AS INDICATED. VERIFY LOCATIONS AND ELEVATIONS ON JOB SITE;
DO NOT DIRECTLY SCALE DRAWINGS. MAKE NECESSARY CHANGES IN ELEVATION, FITTINGS, OR
OFFSETS TO ACCOMMODATE OBSTACLES OR INTERFERENCES.
13. CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR DAMAGE TO THE BUILDING, PIPING OR
EQUIPMENT THAT IS THE RESULT OF WORK FOR INSTALLATION OF THIS CONTRACT.
14. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR PATCH AND REPAIR OF ALL SURFACES TO MATCH EXISTING MATERIALS AND ADJACENT FINISHES ASSOCIATED WITH INSTALLATION/REMOVAL
OF THIS WORK UNLESS SPECIFICALLY NOTED OTHERWISE.
15. WORK SHALL BE COMPLETED TO MAINTAIN ALL NECESSARY AND REQUIRED CLEARANCES,
ACCESSES, AND OPENINGS, SUCH THAT FULL FUNCTIONALITY, PROPER OPERATION, AND REPAIR
AND MAINTENANCE ARE ENSURED.
16. WHERE DEVICE HEIGHT OCCURS AT POINT OF CHANGE OF FINISH, THE DEVICE HEIGHT SHALL BE
ADJUSTED TO OCCUR IN ONE FINISH. ENSURE RESULTING HEIGHT DOES NOT EXCEED ADA
REQUIREMENTS.
17. WHERE DEVICE OCCURS IN BRICK, TILE, OR BLOCK WALLS, THEY SHALL BE MOUNTED AT A VERTICAL MASONRY JOINT & IN EITHER THE TOP OR BOTTOM HORIZONTAL JOINT, CLOSEST TO
THE MOUNTING HEIGHT. ENSURE RESULTING HEIGHT DOES NOT EXCEED ADA REQUIREMENTS.
18. UNLESS OTHERWISE NOTED, ALL MOUNTING HEIGHT DIMENSIONS LISTED ARE TO THE CENTER
LINE OF THE WALL BOX OR DEVICE.
19. ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE LABELED AND
LISTED BY A CERTIFIED TESTING LABORATORY OR AGENCY.
20. DRAWINGS REPRESENT THE SCOPE OF WORK IN GENERAL ARRANGEMENT FORM AND ARE
INTENDED TO SHOW GENERAL ROUTING AND REQUIRED SIZES/CAPACITIES OF SYSTEM
COMPONENTS.
1. THE DEMOLITION PLANS AND NOTES HAVE BEEN PREPARED TO ASSIST THE CONTRACTORS IN IDENTIFYING THE AREAS AND ITEMS OF DEMOLITION AND RENOVATION ASSOCIATED WITH THIS PROJECT. THE INFORMATION PROVIDED IS NOT MEANT TO BE ALL-INCLUSIVE IN TERMS OF LISTING
EACH AND EVERY SPECIFIC TASK TO BE PERFORMED. EACH CONTRACTOR WILL THOROUGHLY
EXAMINE ALL CONTRACT DOCUMENTS PRIOR TO PERFORMING ANY WORK.
2. DEMOLITION WORK INCLUDES, BUT IS NOT LIMITED TO, THE ITEMS INDICATED ON THE DEMOLITION DRAWINGS AND DESCRIBED IN THE DEMOLITION NOTES. THE EXTENT OF THE DEMOLITION WORK
WILL INCLUDE ALL WORK REQUIRED TO COMPLETE THE PROJECT AND ENSURE WHETHER OR NOT
THE WORK IS INDICATED ON THE DRAWINGS.
3. EACH CONTRACTOR SHALL THOROUGHLY EXAMINE AND VERIFY ALL EXISTING CONDITIONS BEFORE
PERFORMING ANY WORK AND IMMEDIATELY NOTIFY THE ARCHITECT, IN WRITING, OF ANY
DISCREPANCIES WITH THE DRAWINGS.
4. ANY WORK PERFORMED AS PART OF THIS CONTRACT REQUIRING OR ALTERATION WILL BE THE
RESPONSIBILITY OF THE RESPECTIVE CONTRACTOR.
5. ALL ITEMS NOTED TO BE REMOVED TO BE DISPOSED OF OFF-SITE BY RESPECTIVE CONTRACTORS, UNLESS NOTED OTHERWISE. WHERE INDICATED ON THE DRAWINGS AND/OR IN THE NOTES AS
SALVAGE AND DELIVER TO OWNER. THE CONTRACTOR WILL CAREFULLY REMOVE INDICATED ITEMS
AND STORE THEM WHERE DIRECTED BY THE OWNER.
6. THE OWNER HAS THE OPTION TO RETAIN POSSESSION OF ANY REMOVED MATERIALS OR
EQUIPMENT. ALL SUCH ITEMS SHALL BE CAREFULLY REMOVED AND STORED AT THE SITE BY THE
CONTRACTOR WHERE DIRECTED BY THE OWNER. ANY MATERIALS OR EQUIPMENT NOT RETAINED
BY THE OWNER WILL BECOME THE PROPERTY OF THE CONTRACTOR AND PROMPTLY REMOVED
FROM SITE.
7. ANY CONTRACTOR REMOVING OR MODIFYING MATERIAL CONTAINING ASBESTOS OR SUSPECTED
OF CONTAINING ASBESTOS WILL NOTIFY THE OWNER AT ONCE AND STOP REMOVAL.
IDENTIFICATION AND/OR REMOVAL OF ASBESTOS CONTAINING MATERIAL WILL BE THE
RESPONSIBILITY OF THE OWNER.
8. REFER TO ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, TECHNOLOGY AND
PLUMBING DRAWINGS FOR DEMOLITION WORK BY RESPECTIVE CONTRACTORS. EACH
CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION ASSOCIATED WITH HIS CONTRACT AND SCOPE
OF WORK. EACH CONTRACTOR IS RESPONSIBLE TO PATCH AND/OR REPAIR ANY AND ALL
CONSTRUCTION AFFECTED BY HIS DEMOLITION. THE EXTENT OF PATCH AND REPAIR SHALL BE AS
REQUIRED TO RECEIVE THE SCHEDULED NEW WORK. ALL CONTRACTORS ARE RESPONSIBLE FOR
COORDINATION OF WORK WITH OTHER CONTRACTORS BEFORE PERFORMING ANY WORK.
9. ALL PATCH AND REPAIR WORK SHALL BE PERFORMED USING MATERIALS THAT MATCH THE
EXISTING ADJACENT CONSTRUCTION. WHERE PATCHING EXISTING MASONRY WALLS OR INFILLING BETWEEN WALLS WITH MASONRY TO MATCH EXISTING, "TOOTH-IN" NEW MASONRY TO EXISTING.
10. EACH CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING CONSTRUCTION SCHEDULED TO
REMAIN. EACH CONTRACTOR IS RESPONSIBLE TO PATCH AND/OR REPAIR ANY AND ALL
CONSTRUCTION AFFECTED BY THEIR DEMOLITION. EACH CONTRACTOR SHALL PATCH (SUBSTRATE
AND FINISHED SURFACES) ANY EXISTING FINISHES AFFECTED BY THEIR RESPECTIVE WORK.
11. EXISTING CONDITIONS INDICATED ARE OBTAINED FROM AVAILABLE SOURCES (EXISTING DRAWINGS, FIELD SURVEYS, ETC.) AND ARE NOT GUARANTEED TO BE TRUE AND EXACT. CONTRACTOR(S)
SHALL FIELD VERIFY EXISTING CONDITIONS AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES
PRIOR TO PROCEEDING WITH THE AFFECTED PORTION OF THE WORK.
12. REMOVAL IN ITS ENTIRETY INCLUDES HANGERS, ELECTRICAL, CONTROLS, ETC., TO LEAVE A LIKE
NEW OR MATCHING EXISTING CONDITION.
GENERAL DEMOLITION NOTES:
A, AMP AMPERE
ABN ABANDON
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AIC AMPERES INTERRUPTING CURRENT
ATS AUTOMATIC TRANSFER SWITCH
AWG AMERICAN WIRE GAUGE
BFF BELOW FINISHED FLOOR
BFG BELOW FINISHED GRADE
BIL BASIC IMPULSE LEVEL
BLDG BUILDING
C CONDUIT
CB CIRCUIT BREAKER
CONC CONCRETE
CONN CONNECTION
CT CURRENT TRANSFORMER
CU COPPER
DET DETAIL
DIA, Ø DIAMETER
DN DOWN
DWG DRAWING
E,(E) ELECTRIC, ELECTRICAL
EC ELECTRICAL CONTRACTOR
ELEV ELEVATION
EM,EMER EMERGENCY
EQUIP EQUIPMENT
ETR EXISTING TO REMAIN
EX,EXIST EXISTING
EXH EXHAUST
EXT EXTERNAL
FA FIRE ALARM
FCU FAN COIL UNIT
FLA FULL LOAD AMPERES
FLEX FLEXIBLE
FLR FLOOR
FIN FINISHED
FT FEET
FU FUSE
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GEN GENERATOR
GR GRADE
GRD GROUND
HP HORSEPOWER
HZ HERTZ
INT INTERRUPTING
KA KILO AMPERE
KCMIL THOUSAND CIRCULAR MILS
KV KILOVOLT
KVA KILOVOLT AMPERES
KVAR KILOVOLT AMPERES REACTIVE
KW KILOWATT
KWH KILOWATT HOUR
LA LIGHTNING ARRESTOR
L-N LINE TO NEUTRAL
MAX MAXIMUM
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MH MANHOLE
MIN MINIMUM
MLO MAIN LUG ONLY
MOV METAL OXIDE VARISTOR
MOD MOTOR OPERATED DAMPER
MVA MEGAVOLT AMPERES
NC NORMALLY CLOSED
NE NORMAL EMERGENCY
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURER'S ASSOCIATION
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NTS NOT TO SCALE
OC ON CENTER
OH OVERHEAD
P POLE
PFFB PROVISIONS FOR FUTURE BREAKER
PH, ɸ PHASE
PNL PANEL
PT POTENTIAL TRANSFORMER
PVC POLYVINYLCHLORIDE
REQ'D REQUIRED
RGS RIGID GALVANIZED STEEL
RLA RUNNING LOAD AMPS
RES RESISTOR
RMC RIGID METAL CONDUIT
RMS ROOT MEAN SQUARE
RPM REVOLUTIONS PER MINUTE
RX REMOVE EXISTING
SEC SECOND
SYM SYMMETRICAL
TEMP TEMPERATURE
TRANS TRANSFORMER
TYP TYPICAL
UG UNDERGROUND
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
V VOLTS
VAC VOLTS ALTERNATING CURRENT
VM VOLT METER
VP VAPOR PROOF
W WIRE
WG WIRE GUARD
W/ WITH
W/O WITHOUT
WT WEIGHT
XFMR TRANSFORMER
DETAIL
SECTION
DETAIL, SECTION, & CONNECTION MARKS
DIRECTION INDICATORS
SECTION LETTER
SHEET DETAIL APPEARS ONSHEET DETAIL APPEARS ON
DETAIL NUMBER
POINT OF CONNECTION TO EXISTING
REMOVE EXISTING FROM OR TO THIS POINT GENERAL SYMBOL NOTES:
1. EXISTING DEVICES TO REMAIN ARE SHOWN IN LIGHT LINEWEIGHT.
2. EXISTING DEVICES TO BE REMOVED ARE SHOWN IN DASHED LINEWEIGHT.
3. NOT ALL ABBREVIATIONS & SYMBOLS MAY APPLY TO THIS PROJECT.
GENERAL NOTES:
X
X X
ABBREVIATIONS
J
J
T
VFC
S S
D
P
FACP
RTS
DH
S
LIGHTING FIXTURE - SEE FIXTURE SCHEDULE
LIGHTING FIXTURES
MOUNTING HEIGHTS DETAIL
PANEL
FINISHED FLOOR
2 3 4 D
W T
18"
46"
56"
78"
90"
X X
Y
ACM
120V SMOKE DAMPER CONNECTIONSD
EQUIPMENT CONNECTION - REFER TO SCHEDULE
M
MOTOR-STARTING SWITCH
DRAWING NOTE - REFER TO DRAWING NOTE LIST ON SHEET (NEW WORK)
FEEDER TAG - REFER TO FEEDER SCHEDULE ON DRAWING EX.XXX
DRAWING NOTE - REFER TO DRAWING NOTE LIST ON SHEET (DEMOLITION)
DRAWING CONVENTIONS
GROUND ROD
LIGHTNING AIR TERMINAL
LIGHTNING PROTECTION
VAV TRANSFORMER, 120VAC PRIMARY, 24VAC SECONDARY, CLASS II, 100VA.
MOUNT TO JUNCTION BOX ABOVE CEILING. PROVIDE PRIMARY FUSE AND
SINGLE-POLE SINGLE-THROW PRIMARY SNAP SWITCH.
24VAC WIRING
HVAC CONTROL POWER
T
DIRECTION ARROWS FOR EXIT SIGNS AS REQUIRED
WALL MOUNTED EXIT SIGN - SEE FIXTURE SCHEDULE
CEILING MOUNTED EXIT SIGN - SEE FIXTURE SCHEDULE
EMERGENCY BATTERY UNIT WITH HEADS- SEE FIXTURE SCHEDULE
# DESCRIPTION DATE
REVISIONS
C O
N
TR
AC
T
D O
C U
M
EN
TS
C
IT
Y O
F R
O C
H
ES
TE
R
H
EM
LO
C
K
FI
LT
R
AT
IO
N P
LA
N
T
R
IX
H
IL
L R
O
AD
, H
EM
LO
C
K, N
Y
03/10/2025
19606.05
KEY PLAN
DATE:
PROJECT #:
DRAWN BY:
CHECKED BY:
SCALE:
VERIFY SCALE
BAR IS ONE (1) INCH LONG
ON ORIGINAL DRAWING:
IF BAR IS NOT ONE (1) INCH LONG,
ADJUST SCALE ACCORDINGLY
0 1
H
VA
C U
PG
R
AD
ES
, N O
.:2
N
N.T.S.
BRW
DSU
ABBREVIATIONS
GENERAL NOTES &
ELECTRICAL SYMBOLS,
E-000
FC-4
FC-3
FC-5
FC-2
LPG
(ETR)
LPC
(ETR)
LPB
(ETR)
HEF-5
HEF-6
HEF-4
HEF-3
(MOUNTED ON FUME
HOOD TO BE REMOVED)
HEF-1
(MOUNTED ON
FUME HOOD TO
BE REMOVED)
HEF-2
(MOUNTED ON
FUME HOOD TO
BE REMOVED)
HEF-7
VFD
MAU-1
HOOD H-2
LTG. & RECEP.
HOOD H-3
LTG. & RECEP.
HOOD H-4
LTG. & RECEP.
HOOD H-1
LTG. & RECEP.
2 2
S
S
S
SS
S
S
D 44 5 6
(ETR)
CHGP-1
CHGP-2
CHGP-1
CHGP-2
CEILING MOUNTED JELLY
JAR LIGHT FIXTURE WITH
RED LAMP
3 3 a,b a,b a,b a,b c,d c,d c,d c,dc,d c,dc,dc,d a b
3c 3d c d f,g f,g f,g h,i h,i h i f g j k j,k j,k j,k j,k a b a,b a,b e e e
HEF-1 (ETR)
LPA (ETR)
HEF-5 (ETR)
HEF-6 (ETR)
HEF-7 (ETR)
EF-8
EF-7 (ETR)
HEF-2 (ETR)
C M
C M
C M
C M
C M
C M
C M
# DESCRIPTION DATE
REVISIONS
C O
N
TR
AC
T
D O
C U
M
EN
TS
C
IT
Y O
F R
O C
H
ES
TE
R
H
EM
LO
C
K
FI
LT
R
AT
IO
N P
LA
N
T
R
IX
H
IL
L R
O
AD
, H
EM
LO
C
K, N
Y
03/10/2025
19606.05
KEY PLAN
DATE:
PROJECT #:
DRAWN BY:
CHECKED BY:
SCALE:
VERIFY SCALE
BAR IS ONE (1) INCH LONG
ON ORIGINAL DRAWING:
IF BAR IS NOT ONE (1) INCH LONG,
ADJUST SCALE ACCORDINGLY
0 1
H
VA
C U
PG
R
AD
ES
, N O
.:2
N
AS INDICATED
BRW
DSU
DEMOLITION
FLOOR PLAN -
PARTIAL SECOND
ED-102
SCALE: 1/4"=1'-0"
PARTIAL SECOND FLOOR PLAN1
DEMO NOTES:
1. DISCONNECT AND REMOVE EXISTING FAN COIL UNIT POWER
BRANCH CIRCUITING BACK TO NEAREST ABOVE CEILING
JUNCTION BOX AND SAVE FOR REUSE.
2. DISCONNECT AND REMOVE EXISTING FUME HOOD POWER
BRANCH CIRCUITING BACK TO NEAREST ABOVE CEILING
JUNCTION BOX AND SAVE FOR REUSE.
3. DISCONNECT AND REMOVE EXISTING FUME HOOD POWER
BRANCH CIRCUITING BACK TO SOURCE.
4. DISCONNECT AND REMOVE EXISTING LUMINAIRE TO
ACCOMMODATE NEW DUCTWORK. SAVE AND PROTECT
LUMINAIRE FOR RELOCATION. DISCONNECT AND REMOVE
LIGHTING BRANCH CIRCUITING BACK TO NEAREST JUNCTION BOX
IN UNAFFECTED AREA AND SAVE FOR REUSE.
5. DISCONNECT AND REMOVE ALL EXISTING CEILING MOUNTED FIRE
ALARM DEVICES, PAGING DEVICES AND EXIT SIGNS TO
ACCOMMODATE CEILING REMOVAL. SAVE AND PROTECT DEVICES
AND EXIT SIGNS FOR RE-INSTALLATION. DISCONNECT AND
REMOVE BRANCH CIRCUITING BACK TO NEAREST ABOVE CEILING
JUNCTION BOX AND SAVE FOR REUSE.
6. DISCONNECT, REMOVE AND DISPOSE OF ALL EXISTING
FLUORESCENT LUMINAIRES WITHIN INDICATED AREA TO
ACCOMMODATE CEILING REMOVAL. DISCONNECT AND REMOVE
LIGHTING BRANCH CIRCUITING BACK TO NEAREST ABOVE
CEILING JUNCTION BOX AND SAVE FOR REUSE.
7. DISCONNECT AND REMOVE EXISTING DUCT SMOKE DETECTOR
TO ACCOMMODATE DUCT REMOVAL. DISCONNECT AND REMOVE
FIRE ALARM BRANCH CIRCUITING BACK TO NEAREST
NON-AFFECTED JUNCTION BOX AND SAVE FOR REUSE.
8. DISCONNECT AND REMOVE EXISTING CHILLED WATER GYLCOL
PUMP POWER BRANCH CIRCUITING BACK TO MOTOR CONTROL
CENTER 'MCC-1' IN FIRST FLOOR ELECTRICAL ROOM. RE-LABEL
BUCKET AS SPARE.
9. DISCONNECT AND REMOVE EXISTING CHILLED WATER GLYCOL
PUMP DISCONNECT AND ASSOCIATED POWER BRANCH
CIRCUITING BACK TO MOTOR CONTROL CENTER IN FIRST FLOOR
ELECTRICAL ROOM. RE-LABEL BUCKET AS SPARE. DISCONNECT
SHALL BE TURNED OVER TO OWNER.
10. DISCONNECT AND REMOVE EXISTING MAKE-UP AIR UNIT
DISCONNECT, VARIABLE FREQUENCY DRIVE AND ASSOCIATED
POWER BRANCH CIRCUITING BACK TO DISTRIBUTION PANEL
'PP1A' IN FIRST FLOOR ELECTRICAL ROOM. RE-LABEL EXISTING
CIRCUIT BREAKER AS SPARE. DRIVE SHALL BE TURNED OVER TO
OWNER.
11. DISCONNECT AND REMOVE EXISTING LIGHTING CONTROL
TOGGLE SWITCHES. EXISTING BACKBOX AND ASSOCIATED
BRANCH CIRCUITING SHALL BE EXISTING TO REMAIN.
12. DISCONNECT AND REMOVE CONTROL STATION FROM EXISTING
RECESSED BACKBOX AND REMOVE WIRING BACK TO MCC IN
FIRST FLOOR ELECTRICAL ROOM. EXISTING RECESSED BACKBOX
AND CONDUIT SHALL REMAIN FOR REUSE BY BMS.
WP
GFI
(ETR)
WP
GFI
(ETR)
WP
GFI
(ETR)
3 9
9 HEF-2
HEF-3
HEF-7
EF-8
CH-1
MAU-1
HEF-5
1HEF-6
HEF-1
6 9HEF-4
# DESCRIPTION DATE
REVISIONS
C O
N
TR
AC
T
D O
C U
M
EN
TS
C
IT
Y O
F R
O C
H
ES
TE
R
H
EM
LO
C
K
FI
LT
R
AT
IO
N P
LA
N
T
R
IX
H
IL
L R
O
AD
, H
EM
LO
C
K, N
Y
03/10/2025
19606.05
KEY PLAN
DATE:
PROJECT #:
DRAWN BY:
CHECKED BY:
SCALE:
VERIFY SCALE
BAR IS ONE (1) INCH LONG
ON ORIGINAL DRAWING:
IF BAR IS NOT ONE (1) INCH LONG,
ADJUST SCALE ACCORDINGLY
0 1
H
VA
C U
PG
R
AD
ES
, N O
.:2
N
AS INDICATED
BRW
DSU
DEMOLITION
PARTIAL ROOF PLAN -
ED-103
SCALE: 1/4"=1'-0"
PARTIAL ROOF PLAN1
DEMO NOTES:
1. DISCONNECT AND REMOVE EXISTING HOOD EXHAUST FAN POWER
BRANCH CIRCUITING (FED FROM PANELBOARD 'LPB') BACK TO
STUBBED-UP CONDULET ON ROOF AND SAVE FOR REUSE.
2. DISCONNECT AND REMOVE EXISTING HOOD EXHAUST FAN POWER
BRANCH CIRCUITING BACK TO PANELBOARD 'LPB' ON SECOND FLOOR
IN ELEC. ROOM 212. EXISTING MOTOR STARTING SWITCH AND
CONTACTOR SHALL REMAIN FOR REUSE.
3. DISCONNECT AND REMOVE EXISTING MAKE-UP AIR UNIT POWER
BRANCH CIRCUITING BACK TO DISTRIBUTION PANELBOARD 'PP1-A' IN
FIRST FLOOR ELECTRICAL ROOM. RE-LABEL EXISTING BREAKER AS A
SPARE.
4. DISCONNECT AND REMOVE EXISTING CHILLER POWER BRANCH
CIRCUITING BACK TO DISTRIBUTION PANELBOARD 'PP1' IN FIRST
FLOOR ELECTRICAL ROOM. RE-LABEL EXISTING BREAKER AS A SPARE.
5. DISCONNECT AND REMOVE EXISTING HOOD EXHAUST FAN POWER
BRANCH CIRCUITING BACK TO MOTOR CONTROL CENTER 'MCC-1' IN
FIRST FLOOR ELECTRICAL ROOM. RE-LABEL BUCKET AS SPARE.
6. DISCONNECT AND REMOVE EXISTING HOOD EXHAUST FAN POWER
BRANCH CIRCUITING BACK TO MOTOR CONTROL CENTER 'MCC-2' IN
FIRST FLOOR ELECTRICAL ROOM. RE-LABEL BUCKET AS SPARE.
7. DISCONNECT AND REMOVE EXISTING EXHAUST FAN POWER BRANCH
CIRCUITING BACK TO PANELBOARD 'LPB' ON SECOND FLOOR AND
REMOVE EXISTING STARTER IN ELEC. ROOM 212.
8. DISCONNECT AND REMOVE LIGHTNING PROTECTION AIR TERMINALS
FROM EXISTING PIECE OF EQUIPMENT AND SAVE FOR REUSE.
DISCONNECT AND REMOVE CONDUCTORS BACK NEAREST NEAREST
MAIN CONDUCTOR CABLE CONNECTOR.
9. DISCONNECT AND REMOVE LIGHTNING PROTECTION AIR TERMINALS
FROM EXISTING PIECE OF EQUIPMENT. DISCONNECT AND REMOVE
CONDUCTORS BACK NEAREST NEAREST MAIN CONDUCTOR CABLE
CONNECTOR.
10. DISCONNECT AND EXTEND EXISTING POWER BRANCH CIRCUITING TO
NEW CONDENSER LOCATION. EXTEND EXISTING LIGHTNING
PROTECTION CABLE TO NEW LOCATION.
PP2A
(ETR)
PP2
(ETR)
PP1A
(ETR)
PP1
(ETR)
UP TO
SECOND
FLOOR
MCC-2 (ETR)
MCC-1 (ETR)
NORMAL
POWER
SWITCH
GEAR
(ETR)
GENERATOR
SELECTOR
(ETR)
ATS-2
(ETR)
ATS-1
(ETR)
EMERG.
POWER
SWITCH
GEAR
(ETR)
LPD
(ETR)
FA
C
P SIMPLEX
4007ES
(ETR)
GENERAL NOTES:
G1. REFER TO DRAWING E-102 FOR CONTINUATION OF PANELBOARD FEEDERS ON
SECOND FLOOR.
SCALE: 1/4"=1'-0"
PARTIAL FIRST FLOOR PLAN1
# DESCRIPTION DATE
REVISIONS
C O
N
TR
AC
T
D O
C U
M
EN
TS
C
IT
Y O
F R
O C
H
ES
TE
R
H
EM
LO
C
K
FI
LT
R
AT
IO
N P
LA
N
T
R
IX
H
IL
L R
O
AD
, H
EM
LO
C
K, N
Y
03/10/2025
19606.05
KEY PLAN
DATE:
PROJECT #:
DRAWN BY:
CHECKED BY:
SCALE:
VERIFY SCALE
BAR IS ONE (1) INCH LONG
ON ORIGINAL DRAWING:
IF BAR IS NOT ONE (1) INCH LONG,
ADJUST SCALE ACCORDINGLY
0 1
H
VA
C U
PG
R
AD
ES
, N O
.:2
N
AS INDICATED
BRW
DSU
NEW WORK
FLOOR PLAN -
PARTIAL FIRST
E-101
DOWN TO
FIRST
FLOOR
PP3PP4
FC-4
FC-3
FC-5
FC-2
LPG
(ETR)
LPC
(ETR)
LPB
(ETR)
VFC VFC VFC VFCVFCVFCVFC VFC
CHGP-1
CHGP-2
MAU-1-SA
MAU-1-SB
HEF-1
HEF-2
EF-10
EF-11
H
S
S
S
SS
S
S
D 4 566
(ETR)
ACM ACM 8 (TYP. OF BOTH MAU-1
SUPPLY FANS)
CEILING MOUNTED JELLY
JAR LIGHT FIXTURE WITH
RED LAMP
D
D
D
HOOD LTG.
& RECEP.
33D a b
LA
a
LA
a
LA
a
LA
a
LA
a
LA
a
LA
b
LA
b
LA
b
LA
b
LA
b
LA
b
LB
b
LB
b
3 a
3D b
VS11
HOOD LTG.
& RECEP. 12
HOOD LTG.
& RECEP. 12
LA
LA
LA LA
LA LA LA
LA
LALA LA
M14
CP
M
WP
GHWP
M
WP
GHWP-1 (ETR)
LPA (ETR)
HEF-5 (ETR)
HEF-6 (ETR)
HEF-7 (ETR)
EF-7 (ETR)
(ETR)
C M
C M
C M
C M
C M
C M
RO
+48"
GLYCOL
MAKE-UP
PACKAGE
(GMU-1)
LPB-23 16
APPROXIMATE LOCATION OF
NEW RACEWAY PENETRATIONS
UP TO ROOF FOR PLATFORM
EQUIPMENT
APPROXIMATE LOCATION OF
NEW RACEWAY PENETRATIONS
UP TO ROOF FOR HOOD
EXHAUST FANS AND DAMPERS
APPROXIMATE LOCATION OF
NEW RACEWAY PENETRATIONS
UP TO ROOF FOR HOOD
EXHAUST FANS AND DAMPERS
HEF-3
DAMPER
HEF-6
DAMPER
HEF-5
DAMPER
HEF-7
DAMPER
# DESCRIPTION DATE
REVISIONS
C O
N
TR
AC
T
D O
C U
M
EN
TS
C
IT
Y O
F R
O C
H
ES
TE
R
H
EM
LO
C
K
FI
LT
R
AT
IO
N P
LA
N
T
R
IX
H
IL
L R
O
AD
, H
EM
LO
C
K, N
Y
03/10/2025
19606.05
KEY PLAN
DATE:
PROJECT #:
DRAWN BY:
CHECKED BY:
SCALE:
VERIFY SCALE
BAR IS ONE (1) INCH LONG
ON ORIGINAL DRAWING:
IF BAR IS NOT ONE (1) INCH LONG,
ADJUST SCALE ACCORDINGLY
0 1
H
VA
C U
PG
R
AD
ES
, N O
.:2
N
1/8" = 1'-0"
BRW
DSU
NEW WORK
FLOOR PLAN -
PARTIAL SECOND
E-102
GENERAL NOTES:
G1. COORDINATE FINAL ROUTING AND INSTALLATION OF
PANELBOARD FEEDERS WITH OWNER PRIOR TO
ROUGHING-IN. PROPOSED ROUTE SHOWN FOR BIDDING
PURPOSES ONLY.
G2. REFER TO DRAWING E-101 FOR CONTINUATION OF
PANELBOARD FEEDERS ON FIRST FLOOR.
G3. ALL NEW FIRE ALARM DEVICES MUST BE U.L. LISTED FOR USE
WITH EXISTING, ADDRESSABLE, SIMPLEX 4007ES FIRE ALARM
CONTROL SYSTEM.
G4. UNLESS NOTED OTHERWISE, UTILIZE 2#12, 1#12 GND FOR ALL
BRANCH CIRCUITING.
G5. REFER TO WIRING DIAGRAMS ON DRAWING E-501 FOR
ADDITIONAL LIGHTING CONTROL SYSTEM REQUIREMENTS
AND INFORMATION.
SCALE: 1/4"=1'-0"
PARTIAL SECOND FLOOR PLAN1
#KEYED NOTES:
1. EXTEND AND RECONNECT EXISTING POWER CIRCUIT TO NEW
FAN COIL UNIT.
2. PROVIDE NEW 30-CIRCUIT, 125A MLO, 480/277V, SURFACE
MOUNTED, NEMA 3R, PANELBOARD AT LOCATION SHOWN.
PROVIDE FEEDER (4#1, 1#6 GND IN 2" C) BACK TO
PANELBOARD 'PP1A' IN FIRST FLOOR ELECTRIC ROOM.
PROVIDE NEW 125A-3P CIRCUIT BREAKER IN EXISTING
SQUARE I-LINE PANELBOARD; KAIC RATING OF NEW BREAKER
SHALL MATCH KAIC RATING OF EXISTING PANELBOARD.
3. PROVIDE NEW 30-CIRCUIT, 125A MLO, 480/277V, SURFACE
MOUNTED, NEMA 3R, PANELBOARD AT LOCATION SHOWN.
PROVIDE FEEDER (4#1, 1#6 GND IN 2"C) BACK TO
PANELBOARD 'PP2' IN FIRST FLOOR ELECTRIC ROOM.
PROVIDE NEW 125A-3P CIRCUIT BREAKER IN EXISTING
SQUARE D I-LINE PANELBOARD; KAIC RATING OF NEW
BREAKER SHALL MATCH KAIC RATING OF EXISTING
PANELBOARD.
4. PROVIDE NEW GLARE-FREE LED FLAT PANEL LUMINAIRES AT
LOCATIONS SHOWN WITHIN INDICATED AREA. EXTEND AND
MODIFY EXISTING LIGHT BRANCH CIRCUITING TO
ACCOMMODATE NEW LIGHTING CONTROLS. PROVIDE NEW
0-10V BRANCH CIRCUITING AND CONNECT TO DIMMING
SWITCHES INDICATED OR TO THE LOCAL DIMMING SWITCH IN
THE SPACE.
5. UPON COMPLETION OF ABOVE CEILING WORK, REINSTALL
ALL EXISTING CEILING MOUNTED FIRE ALARM AND PAGING
DEVICES, AS WELL AS ALL CEILING MOUNTED EXIT SIGNS,
BACK IN THEIR ORIGINAL LOCATIONS AND RECONNECT TO
EXISTING BRANCH CIRCUITING.
6. RELOCATE AND REINSTALL EXISTING LUMINAIRES TO
ACCOMMODATE NEW DUCTWORK.
7. PROVIDE NEW DUCT SMOKE DETECTOR IN NEW MAU-1 DUCT.
EXTEND AND RECONNECT EXISTING FIRE ALARM BRANCH
CIRCUITING FROM PREVIOUS DUCT DETECTOR LOCATION TO
NEW LOCATION.
8. PROVIDE FIRE ALARM FAN SHUTDOWN RELAYS TO
SHUTDOWN MAKE-UP AIR UNIT SUPPLY FANS IN THE EVENT
THE DUCT SMOKE DETECTOR GOES INTO ALARM.
9. PROVIDE NEW LINE VOLTAGE, 0-10V DIMMER SWITCH OR LINE
VOLTAGE, MULTI-WAY SWITCH WITH 0-10V DIMMER (TYPE AS
INDICATED) TO ALLOW USER TO CONTROL ON/OFF
OPERATION AND LIGHT LEVELS OF LUMINAIRES WITHIN THE
SPACE. PROVIDE NEW 2-GANG (ONE (1) DECORA, ONE (1)
BLANK) STAINLESS STEEL COVERPLATE.
10. PROVIDE NEW LINE VOLTAGE, MULTI-WAY SWITCH TO ALLOW
USER TO CONTROL ON/OFF OPERATION OF LUMINAIRES
WITHIN THE SPACE. PROVIDE NEW 2-GANG (ONE (1) DECORA,
ONE (1) BLANK) STAINLESS STEEL COVERPLATE.
11. PROVIDE NEW LINE VOLTAGE VACANCY SENSOR SWITCH TO
ALLOW FOR AUTOMATIC OFF, MANUAL-ON OPERATION OF
LUMINAIRES WITHIN THE SPACE. PROVIDE NEW 1-GANG
(DECORA) STAINLESS STEEL COVERPLATE.
12. EXTEND AND RECONNECT EXISTING POWER BRANCH
CIRCUITING TO NEW HOOD.
13. TRANSITION FEEDER RACEWAY FROM ELECTRICAL METAL
TUBING (EMT) CONDUIT TO RIGID METAL CONDUIT (RMC)
BEFORE ENTERING TANK ROOM.
14. PROVIDE MOTOR-STARTING SWITCH FOR HEF-3 AND LOCATE
ABOVE CEILING.
15. RE-LABEL EXISTING MOTOR STARTING SWITCH AND
CONTACTOR WITH NEW CONTROLLED LOAD AND CIRCUIT
INFORMATION.
16. PROVIDE NEW 20A-1P CIRCUIT BREAKER TO MATCH EXISTING
PANELBOARD CONSTRUCTION (SQUARE D) AND KAIC RATING.
17. APPROXIMATE LOCATION OF MOTORIZED DAMPER
ASSOCIATED WITH INDICATED ROOFTOP EXHAUST FAN.
REFER TO DETAIL 2/E-500 FOR WIRING REQUIREMENTS.
18. APPROXIMATE LOCATION OF MOTORIZED DAMPER
ASSOCIATED WITH INDICATED ROOFTOP EXHAUST FAN.
REFER TO DETAIL 1/E-500 FOR WIRING REQUIREMENTS.
RTS
ROUTED ABOVE
SUSPENDED CEILING
4'-0"
WP
GFI
(ETR)
WP
GFI
(ETR)
WP
GFI
(ETR)
WP
GFI
BUFFER
TANK
CHGP
CHGP
CH
CH
MAU
1-SA
MAU
1-SB
HEF
HEF
EF
HEF
HEF
1CATWALK
STRUCTURE
5 1
MAU-1
HEF
HEF
EF
LPB-47
1 5
7 APPROXIMATE
LOCATION OF
EXHAUST FAN
DAMPER
7 APPROXIMATE
LOCATION OF
EXHAUST FAN
DAMPER
EXISTING AIR
VENT BELOW
PLATFORM
(ETR)
M
WP
M
WP
M
WP
M
WP
LPC-9
LPC-9
LPC-9
LPC-9
LPB-32
LPB-35
LPB-33
1 5
APPROXIMATE LOCATION OF
NEW RACEWAY PENETRATIONS
DOWN TO FILTER ROOM
(LOCATED BENEATH PLATFORM)
E-500
M
WP
LPB-45
APPROXIMATE
LOCATION OF
MAKE-UP AIR
UNIT DAMPER
APPROXIMATE LOCATION OF
NEW RACEWAY PENETRATIONS
DOWN TO SECOND FLOOR
E-500
APPROXIMATE LOCATION OF
NEW RACEWAY PENETRATIONS
DOWN TO SECOND FLOOR
E-500
# DESCRIPTION DATE
REVISIONS
C O
N
TR
AC
T
D O
C U
M
EN
TS
C
IT
Y O
F R
O C
H
ES
TE
R
H
EM
LO
C
K
FI
LT
R
AT
IO
N P
LA
N
T
R
IX
H
IL
L R
O
AD
, H
EM
LO
C
K, N
Y
03/10/2025
19606.05
KEY PLAN
DATE:
PROJECT #:
DRAWN BY:
CHECKED BY:
SCALE:
VERIFY SCALE
BAR IS ONE (1) INCH LONG
ON ORIGINAL DRAWING:
IF BAR IS NOT ONE (1) INCH LONG,
ADJUST SCALE ACCORDINGLY
0 1
H
VA
C U
PG
R
AD
ES
, N O
.:2
N
AS INDICATED
BRW
DSU
NEW WORK
PARTIAL ROOF PLAN -
E-103
#KEYED NOTES:
1. EXTEND EXISTING ROOFTOP LIGHTNING PROTECTION SYSTEM TO
PROTECT NEW ROOFTOP EQUIPMENT AND ASSOCIATED PLATFORM
SYSTEM. SYSTEM SHALL BE DESIGNED AND INSTALLED IN
ACCORDANCE WITH NFPA 780 AND U.L. STANDARD 96A. PROVIDE NEW
U.L. MASTER LABEL FOR ENTIRE SYSTEM AND SUBMIT CERTIFICATE
TO OWNER UPON COMPLETION OF PROJECT. EXISTING AIR
TERMINALS AND GROUNDING CABLES APPEAR TO BE ALUMINUM;
FIELD VERIFY AND MATCH NEW WITH EXISTING. SUBMIT SYSTEM
DESIGN TO ENGINEER FOR REVIEW DURING SUBMITTAL PORTION OF
PROJECT.
2. PROVIDE 120V BRANCH CIRCUITING TO FACTORY MOUNTED,
UN-POWERED, GFI RECEPTACLE ON SIDE OF MAKE-UP AIR UNIT.
3. RE-ATTACH EXISTING ROOFTOP LIGHTNING PROTECTION EQUIPMENT
TO REPLACEMENT EQUIPMENT. SYSTEM SHALL BE DESIGNED AND
INSTALLED IN ACCORDANCE WITH NFPA 780 AND U.L. STANDARD 96A.
PROVIDE NEW U.L. MASTER LABEL FOR ENTIRE SYSTEM AND SUBMIT
CERTIFICATE TO OWNER UPON COMPLETION OF PROJECT. EXISTING
AIR TERMINALS AND GROUNDING CABLES APPEAR TO BE ALUMINUM;
FIELD VERIFY AND MATCH NEW WITH EXISTING. SUBMIT SYSTEM
DESIGN TO ENGINEER FOR REVIEW DURING SUBMITTAL PORTION OF
PROJECT.
4. EXTEND AND RECONNECT EXISTING 120V POWER CIRCUIT TO
REPLACEMENT HOOD EXHAUST FAN AND NEW MOTORIZED DAMPER
(LOCATED BELOW ROOF). POWER CIRCUIT SHALL BE ROUTED
THROUGH NEW INTERPOSING RELAY PROVIDED BY BMS. REFER TO
DETAIL 2/E-500 FOR ADDITIONAL WIRING REQUIREMENTS.
5. REFER TO ELECTRIC EQUIPMENT AND CONTROL SCHEDULE ON
DRAWING E-700 FOR EQUIPMENT POWER REQUIREMENTS.
6. PROVIDE NEW 20A-1P CIRCUIT BREAKER TO MATCH EXISTING
PANELBOARD CONSTRUCTION (SQUARE D) AND KAIC RATING.
7. PROVIDE 120V BRANCHING CIRCUITING (2#12, 1#12 GND., IN 3/4" RMC
CONDUIT) TO EXHAUST FAN DAMPER MOUNTED IN ROOFTOP
DUCTWORK. BRANCH CIRCUIT SHALL BE ROUTED THROUGH DAMPER
CONTROL RELAY IN ASSOCIATED VARIABLE FREQUENCY MOTOR
CONTROLLER (VFC) INSIDE OF BUILDING. PROVIDE WEATHERPROOF,
LOCKABLE, MOTOR-STARTING SWITCH TO PROVIDE LOCAL MEANS OF
DISCONNECT. PROVIDE AN ADDITIONAL 1/2" RMC CONDUIT WITH
PULLSTRING FROM DAMPER DOWN TO VFC FOR LOW VOLTAGE
CONTROL CABLING. REFER TO DETAIL 3/E-500 FOR ADDITIONAL
WIRING REQUIREMENTS.
8. UTILIZE SPARE 20A-1P CIRCUIT BREAKER IN EXISTING PANELBOARD.
9. POWER AND CONTROL RACEWAYS FOR PLATFORM EQUIPMENT
SHALL BE ROUTED UP TO ROOF AT SAME LOCATION AS MECHANICAL
PIPING AND SHALL SHARE THE SAME G.C. FURNISHED AND INSTALLED
PIPE & RACEWAY VAULT. COORDINATE EXACT QUANTITY AND SIZE OF
RACEWAYS REQUIRED TO BE ROUTED THROUGH VAULT WITH G.C..
ONCE THE RACEWAYS EXIT THE VAULT THEY SHALL BE SUPPORTED
FROM BOTTOM SIDE OF PLATFORM.
10. PROVIDE 120V BRANCHING CIRCUITING (2#12, 1#12 GND., IN 3/4" RMC
CONDUIT) TO MAKE-UP AIR UNIT DAMPER. BRANCH CIRCUIT SHALL BE
ROUTED THROUGH DAMPER CONTROL RELAYS IN ASSOCIATED
SUPPLY FAN VARIABLE FREQUENCY MOTOR CONTROLLERS (VFC)
INSIDE OF BUILDING. PROVIDE WEATHERPROOF, LOCKABLE,
MOTOR-STARTING SWITCH TO PROVIDE LOCAL MEANS OF
DISCONNECT. PROVIDE AN ADDITIONAL 1/2" RMC CONDUIT WITH
PULLSTRING FROM DAMPER DOWN TO EACH SUPPLY FAN VFC FOR
LOW VOLTAGE CONTROL CABLING. REFER TO DETAIL 6/E-500 FOR
ADDITIONAL WIRING REQUIREMENTS.
11. POWER AND CONTROL RACEWAYS FOR FUME HOOD EXHAUST FANS
AND ASSOCIATED DAMPERS SHALL BE ROUTED THROUGH A G.C.
FURNISHED AND INSTALLED PIPE & RACEWAY VAULT. COORDINATE
EXACT QUANTITY AND SIZE OF RACEWAYS REQUIRED TO BE ROUTED
THROUGH VAULT WITH G.C..
GENERAL NOTES:
G1. ALL ROOF PENETRATIONS, FLASHING AND SEALING SHALL BE PROVIDED
BY THE GENERAL CONTRACTOR (G.C.).
SCALE: 1/4"=1'-0"
PARTIAL ROOF PLAN1
C O
N
TR
AC
T
D O
C U
M
EN
TS
C
IT
Y O
F R
O C
H
ES
TE
R
H
EM
LO
C
K
FI
LT
R
AT
IO
N P
LA
N
T
R
IX
H
IL
L R
O
AD
, H
EM
LO
C
K, N
Y
03/10/2025
19606.05
KEY PLAN
DATE:
PROJECT #:
DRAWN BY:
CHECKED BY:
SCALE:
VERIFY SCALE
BAR IS ONE (1) INCH LONG
ON ORIGINAL DRAWING:
IF BAR IS NOT ONE (1) INCH LONG,
ADJUST SCALE ACCORDINGLY
0 1
H
VA
C U
PG
R
AD
ES
, N O
.:2
N
N.T.S.
BRW
DSU
WIRING DIAGRAMS
DETAILS &
E-500
SCALE: NONE
VFC CONTROLLED EXHAUST FAN DAMPER WIRING DIAGRAM3
VARIABLE FREQUENCY MOTOR CONTROLLER (VFC)
DISCHARGE DAMPER
CONTROL RELAY
OUTPUT
DAMPER END SWITCH
POSITION WHEN
DAMPER IS CLOSED
+24V (AUX. VOLTAGE OUTPUT +24VDC , MAX 250 mA)
PROGRAMMABLE DIGITAL INPUT (PERMISSIVE SIGNAL)
LINE (120V)
NEUTRAL
120V
MOTORIZED
DAMPER
LN
DAMPER
ACTUATOR
POWER
2#14 AWG
IN 1/2"C
2#12 AWG
IN 3/4"C
WEATHERPROOF,
LOCKABLE,
MOTOR-STARTING
SWITCH
TO BMS
RIB
120 VOLTS
TO BMS
CS
SCALE: NONE
BMS CONTROLLED EXHAUST FAN AND DAMPER WIRING DIAGRAM1
RIB
120 VOLTS
TO BMS
CS
SCALE: NONE
BMS CONTROLLED EXHAUST FAN (VIA CONTACTOR )
AND DAMPER WIRING DIAGRAM2
M
LOCKABLE
MOTOR-
STARTING
SWITCH
#DETAIL KEYED NOTES:
1. LOCKABLE MOTOR-STARTING SWITCH PROVIDED BY ELECTRICAL CONTRACTOR.
2. INTERPOSING RELAY (RELAY IN A BOX (RIB)) FURNISHED BY MECHANICAL
CONTRACTOR AND INSTALLED BY ELECTRICAL CONTRACTOR. BMS WIRING BY
MECHANICAL CONTRACTOR.
3. CURRENT SWITCH FURNISHED BY MECHANICAL CONTRACTOR AND INSTALLED BY
ELECTRICAL CONTRACTOR. BMS WIRING BY MECHANICAL CONTRACTOR.
4. EXHAUST FAN PROVIDED WITH INTEGRAL DISCONNECT SWITCH. 120V MOTORIZED
DAMPER TO FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY
ELECTRICAL CONTRACTOR.
INTERPOSING
RELAY2
CURRENT
SWITCH3
EXHAUST
FAN & 120V
MOTORIZED
DAMPER
#DETAIL KEYED NOTES:
1. EXISTING LOCKABLE MOTOR-STARTING SWITCH WITH PILOT TO REMAIN.
2. INTERPOSING RELAY (RELAY IN A BOX (RIB)) FURNISHED BY MECHANICAL CONTRACTOR AND
INSTALLED BY ELECTRICAL CONTRACTOR. BMS WIRING BY MECHANICAL CONTRACTOR.
3. CURRENT SWITCH FURNISHED BY MECHANICAL CONTRACTOR AND INSTALLED BY
ELECTRICAL CONTRACTOR. BMS WIRING BY MECHANICAL CONTRACTOR.
4. EXHAUST FAN PROVIDED WITH INTEGRAL DISCONNECT SWITCH. 120V MOTORIZED DAMPER
TO FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR, WIRED BY ELECTRICAL
CONTRACTOR.
5. EXISTING CONTACTOR TO REMAIN. REWIRE CONTROL CIRCUIT THROUGH NEW INTERPOSING
RELAY AS SHOWN.
EXISTING
LOCKABLE
MOTOR-
STARTING
SWITCH
INTERPOSING
RELAY2
CURRENT
SWITCH3
EXISTING
CONTACTOR5
TO BMS
EF
DM
EXHAUST
FAN & 120V
MOTORIZED
DAMPER
EF
DM
#DETAIL KEYED NOTES:
1. WEATHERPROOF,LOCKABLE, MOTOR-STARTING SWITCH PROVIDED BY ELECTRICAL CONTRACTOR.
2. VARIABLE FREQUENCY MOTOR CONTROLLER (VFC) PROVIDED BY ELECTRICAL CONTRACTOR.
3. ALL LOW VOLTAGE AND 120V POWER BRANCH CIRCUITING (WIRING & RACEWAY) ASSOCIATED WITH CONTROLLING AND POWERING MOTORIZED DAMPER SHALL BE FURNISHED, INSTALLED AND TERMINATED BY ELECTRICAL
CONTRACTOR.
4. DAMPER END SWITCH SHALL BE FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR AND WIRED BY ELECTRICAL CONTRACTOR. END SWITCH SHALL BE WIRED INTO PERMISSIVE CONTROL CIRCUIT OF VFC.
1 2
RIB
120 VOLTS
TO BMS
CS
SCALE: NONE
BMS CONTROLLED PUMP (VIA CONTACTOR )
WIRING DIAGRAM4
M
#DETAIL KEYED NOTES:
1. EXISTING LOCKABLE MOTOR-STARTING SWITCH WITH PILOT TO REMAIN.
2. INTERPOSING RELAY (RELAY IN A BOX (RIB)) FURNISHED BY MECHANICAL CONTRACTOR AND
INSTALLED BY ELECTRICAL CONTRACTOR. BMS WIRING BY MECHANICAL CONTRACTOR.
3. CURRENT SWITCH FURNISHED BY MECHANICAL CONTRACTOR AND INSTALLED BY
ELECTRICAL CONTRACTOR. BMS WIRING BY MECHANICAL CONTRACTOR.
4. EXISTING CONTACTOR TO REMAIN. REWIRE CONTROL CIRCUIT THROUGH NEW INTERPOSING
RELAY AS SHOWN.
5. LOCKABLE MOTOR-STARTING SWITCH PROVIDED BY ELECTRICAL CONTRACTOR.
EXISTING
LOCKABLE
MOTOR-
STARTING
SWITCH
INTERPOSING
RELAY2
CURRENT
SWITCH3
EXISTING
CONTACTOR4
TO BMS
PUMP
LOCKABLE
MOTOR-
STARTING
SWITCH
VFC CONTROLLED MAKE-UP AIR UNIT DAMPER WIRING DIAGRAM5
VARIABLE FREQUENCY MOTOR CONTROLLER (VFC)
(MAU-1-SA)
DISCHARGE DAMPER
CONTROL RELAY
OUTPUT
DAMPER END SWITCH
POSITION WHEN
DAMPER IS CLOSED
(TYP.)
+24V (AUX. VOLTAGE OUTPUT +24VDC , MAX 250 mA)
PROGRAMMABLE DIGITAL INPUT (PERMISSIVE SIGNAL)
LINE (120V)
NEUTRAL
120V
MOTORIZED
DAMPER
LN
DAMPER
ACTUATOR
POWER
2#14 AWG
IN 1/2"C
2#12 AWG
IN 3/4"C
WEATHERPROOF,
LOCKABLE,
MOTOR-STARTING
SWITCH
#DETAIL KEYED NOTES:
1. WEATHERPROOF,LOCKABLE, MOTOR-STARTING SWITCH PROVIDED BY ELECTRICAL CONTRACTOR.
2. VARIABLE FREQUENCY MOTOR CONTROLLER (VFC) PROVIDED BY ELECTRICAL CONTRACTOR.
3. ALL LOW VOLTAGE AND 120V POWER BRANCH CIRCUITING (WIRING & RACEWAY) ASSOCIATED WITH CONTROLLING AND POWERING MOTORIZED DAMPER SHALL BE FURNISHED, INSTALLED AND TERMINATED BY ELECTRICAL CONTRACTOR.
4. PROVIDE, WIRE AND PROGRAM ADDRESSABLE FIRE ALARM CONTROL MODULE TO INITIATE A SHUT DOWN OF THE FAN IN THE EVENT THE ASSOCIATED DUCT SMOKE DETECTOR GOES INTO ALARM. MODULE SHALL BE MOUNTED WITHIN 3-FEET OF
CONTROLLER AND WIRED INTO PERMISSIVE CONTROL CIRCUIT OF VFC.
5. FREEZE STAT SHALL BE FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR AND WIRED BY ELECTRICAL CONTRACTOR.
FREEZE STAT SHALL BE WIRED INTO PERMISSIVE CONTROL CIRCUITS OF VFC'S.
6. DAMPER END SWITCH SHALL BE FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR AND WIRED BY ELECTRICAL
CONTRACTOR. END SWITCH SHALL BE WIRED INTO PERMISSIVE CONTROL CIRCUITS OF VFC'S.
2#12 AWG
IN 3/4"C
SCALE: NONE
FIRE ALARM FAN
SHUTDOWN RELAY
VARIABLE FREQUENCY MOTOR CONTROLLER (VFC)
(MAU-1-SB)
DISCHARGE DAMPER
CONTROL RELAY
OUTPUT
+24V (AUX. VOLTAGE OUTPUT +24VDC , MAX 250 mA)
PROGRAMMABLE DIGITAL INPUT (PERMISSIVE SIGNAL)
22#14 AWG
IN 1/2"C
FIRE ALARM FAN
SHUTDOWN RELAY
FREEZE STAT
WITH TWO (2)
SPDT CONTACTS
12" MIN.
POWER AND CONTROL
RACEWAYS
ROOF PIPE & RACEWAY VAULT, AS
MANUFACTURED BY RPH OR EQUIVALENT,
FURNISHED AND INSTALLED BY GENERAL
CONSTRUCTION CONTRACT.
SEAL WATERTIGHT AROUND
RACEWAYS.
ROOF RACEWAY VAULT PENETRATION6 SCALE: NONE
DAMPER END SWITCH WITH
TWO (2) SPDT CONTACTS
DAMPER END
SWITCH WITH
SPDT CONTACT
C O
N
TR
AC
T
D O
C U
M
EN
TS
C
IT
Y O
F R
O C
H
ES
TE
R
H
EM
LO
C
K
FI
LT
R
AT
IO
N P
LA
N
T
R
IX
H
IL
L R
O
AD
, H
EM
LO
C
K, N
Y
03/10/2025
19606.05
KEY PLAN
DATE:
PROJECT #:
DRAWN BY:
CHECKED BY:
SCALE:
VERIFY SCALE
BAR IS ONE (1) INCH LONG
ON ORIGINAL DRAWING:
IF BAR IS NOT ONE (1) INCH LONG,
ADJUST SCALE ACCORDINGLY
0 1
H
VA
C U
PG
R
AD
ES
, N O
.:2
N
N.T.S.
BRW
DSU
WIRING DIAGRAMS
& LIGHTING CONTROL
LUMINAIRE SCHEDULE
E-501
SEQUENCE OF OPERATION:
VACANCY SENSOR: UPON ENTERING THE SPACE THE OCCUPANT SHALL BE REQUIRED TO MANUALLY TURN ON THE LUMINAIRES VIA THE LINE VOLTAGE VACANCY SENSOR SWITCH; THE SWITCH SENSOR SHALL NOT AUTOMATICALLY TURN ON THE LUMINAIRES. ONCE THE OCCUPANT HAS LEFT THE SPACE THE SWITCH
SENSOR SHALL TURN OFF THE LUMINAIRES AFTER 20 MINUTES OF INACTIVITY.
UNSWITCHED HOT
NEUTRAL
LUMINAIRES
LINE VOLTAGE
SENSOR SWITCH
SWITCHED
HOT
NEUTRAL
SYMBOL:
: LINE VOLTAGE VACANCY SENSOR SWITCH
VS
SCALE: NONE
LINE VOLTAGE SENSOR SWITCH WIRING DIAGRAM3
SEQUENCE OF OPERATION:
UPON ENTERING THE SPACE THE OCCUPANT SHALL BE REQUIRED TO MANUALLY TURN ON THE LUMINAIRES VIA THE LINE VOLTAGE, 0-10V DIMMING SWITCH. LUMINAIRES SHALL RETURN TO LAST DIMMING LEVEL WHEN INITIALLY TURNED ON AND THEN CAN BE MANUALLY RAISED OR LOWERED TO THE DESIRED LEVEL BY THE OCCUPANT. THE OCCUPANT MUST MANUALLY TURN
OFF THE LUMINAIRES WHEN LEAVING THE SPACE.
UNSWITCHED HOT
NEUTRAL
+0-10 VDC
LUMINAIRES
LINE VOLTAGE,
0-10V DIMMER
SWITCH
SWITCHED
HOT
NEUTRAL
COM
SYMBOL:
: LINE VOLTAGE, 0-10V DIMMER SWITCH
ON/OFF
D
SCALE: NONE
LINE VOLTAGE 0-10V DIMMER SWITCH WIRING DIAGRAM2
SEQUENCE OF OPERATION:
UPON ENTERING THE SPACE THE OCCUPANT SHALL BE REQUIRED TO MANUALLY TURN ON THE LUMINAIRES VIA A LINE VOLTAGE, MULTI-WAY SWITCH (DIMMING OR NON-DIMMING). LUMINAIRES SHALL RETURN TO LAST DIMMING LEVEL WHEN INITIALLY TURNED ON AND THEN CAN BE MANUALLY RAISED OR LOWERED TO THE DESIRED LEVEL BY THE OCCUPANT AT A MULTI-WAY SWITCH WITH 0-10V DIMMER. THE OCCUPANT MUST MANUALLY TURN OFF THE LUMINAIRES WHEN LEAVING THE
SPACE.
UNSWITCHED HOT
NEUTRAL
+0-10 VDC
LUMINAIRES
LINE VOLTAGE,
MULTI-WAY SWITCH
WITH 0-10V DIMMER
SWITCHED
HOT
NEUTRAL
COM
SYMBOL:
: LINE VOLTAGE, MULTI-WAY SWITCH
WITH 0-10V DIMMER
: LINE VOLTAGE, MULTI-WAY SWITCH
ON/OFF
LINE VOLTAGE,
MULTI-WAY
SWITCH
ON/OFF
TRAVELER WIRE
UNSWITCHED HOT
NEUTRAL
3D
SCALE: NONE
LINE VOLTAGE MULTI-WAY SWITCH WITH 0-10V DIMMING WIRING DIAGRAM1
LUMINAIRE SCHEDULE
TYPE
MANUFACTURER
(DESIGN MAKE) CAT. NUMBER (DESIGN MAKE) COLOR
TEMP.
MIN.
CRI LUMENS WATTAGE
DIMMING
(DOWN TO %) MOUNTING DESCRIPTION FINISH AREA USED
LA LITHONIA EPANL-2X4-6000LM-80CRI-35K-MIN1-EZT-M
VOLT 3500K 80 6,364 55 0-10 (1%) RECESSED 2'x4' LED, EDGE-LIT, GLARE-FREE, FLAT PANEL LUMINAIRE
WITH SATIN WHITE LENS WHITE VARIOUS
LB LITHONIA EPANL-2X2-3400LM-80CRI-35K-MIN1-EZT-M
VOLT 3500K 80 3,428 30 0-10 (1%) RECESSED 2'x2' LED, EDGE-LIT, GLARE-FREE, FLAT PANEL LUMINAIRE
WITH SATIN WHITE LENS WHITE VARIOUS
GENERAL NOTES:
1. ALL LUMINAIRES SHALL UTILIZE LED LAMPS.
2. ALL LUMINAIRES SHALL UTILIZE 120V.
C O
N
TR
AC
T
D O
C U
M
EN
TS
C
IT
Y O
F R
O C
H
ES
TE
R
H
EM
LO
C
K
FI
LT
R
AT
IO
N P
LA
N
T
R
IX
H
IL
L R
O
AD
, H
EM
LO
C
K, N
Y
03/10/2025
19606.05
KEY PLAN
DATE:
PROJECT #:
DRAWN BY:
CHECKED BY:
SCALE:
VERIFY SCALE
BAR IS ONE (1) INCH LONG
ON ORIGINAL DRAWING:
IF BAR IS NOT ONE (1) INCH LONG,
ADJUST SCALE ACCORDINGLY
0 1
H
VA
C U
PG
R
AD
ES
, N O
.:2
N
N.T.S.
BRW
DSU
SCHEDULES
E-700
ELECTRIC EQUIPMENT AND CONTROL SCHEDULE
GENERAL NOTES:
A. UNLESS NOTED OTHERWISE, ALL DEVICES PROVIDED BY THE ELECTRICAL CONTRACTOR.
B. ITEM ID INDICATES EQUIPMENT TAG USED ON FLOOR PLANS.
C. PROVIDE OVERLOADS, SIZE AS REQUIRED, BY THE DIVISION 23 CONTRACTOR.
D. REFER TO PLANS FOR CONTROL EQUIPMENT AND DISCONNECT LOCATIONS.
E. "NF" INDICATES NON-FUSED.
EQUIPMENT POWER SOURCE, PROTECTION & WIRING CONTROLLERS
DISCONNECT
SWITCH
REF.
NOTES
ITEM
IDITEM
ID NAME DRAWING
NUMBER HP KW PHASE SYSTEM
VOLTS FLA MCA
PANEL or
CONTROL
CENTER
OVER
CURRENT
PROTECTION
POWER WIRING FROM PANEL TO
CONTROL UNIT AND FROM
CONTROL UNIT TO EQUIPMENT
VA
R
IA
BL
E
FR
EQ
U
EN
C
Y M
O
TO
R C
O N
TR
O
LL
ER
FR
EE
ZE
S
TA
T
(P R
O
VI
D
ED
B Y
M
EC
H
C O
N
TR
AC
TO
R
FA
C
TO
R
Y M
O U
N
TE
D C
O N
TR
O
LS
M O
TO
R
-S
TA
R
TI
N G
S W
IT
C
H
C O
N
TR
O
LL
ED
B
Y
IN
TE
R
PO
SI
N G
R
EL
AY
(R
EL
AY
P R
O
VI
D
ED
B Y
BM
S)
FI
R
E
AL
AR
M
F
AN
S H
U
TD
O W
N R
EQ
U
IR
ED
C O
N
TR
O
LL
ER
N
EM
A
R
AT
IN
G
SW
IT
C H
A M
PS
FU
SE
S
IZ
E
N
EM
A R
AT
IN
G
PHASE/
NEUTRAL GROUND CONDUIT
CHGP-1 CHILLER GLYCOL PUMP E-103 5 3 460 7.6 PP3-1,3,5 20A-3P 3#12 1#12 3/4" X 3R 30 NF 3R 3,4 CHGP-1
CHGP-2 CHILLER GLYCOL PUMP E-103 5 3 460 7.6 PP4-1,3,5 20A-3P 3#12 1#12 3/4" X 3R 30 NF 3R 3,4 CHGP-2
MAU-1-SA MAKE-UP AIR UNIT E-103 7 1/2 3 460 11.0 PP3-2,4,6 20A-3P 3#12 1#12 3/4" X X X 3R -- -- -- 1,3,4,6 MAU-1-SA
MAU-1-SB MAKE-UP AIR UNIT E-103 7 1/2 3 460 11.0 PP4-2,4,6 20A-3P 3#12 1#12 3/4" X X X 3R -- -- -- 1,3,4,6 MAU-1-SB
CH-1 CHILLER E-103 3 460 47.4 52.5 PP3-7,9,11 70A-3P 3#4 1#10 1-1/4" X -- -- -- -- 1,4 CH-1
CH-2 CHILLER E-103 3 460 47.4 52.5 PP4-7,9,11 70A-3P 3#4 1#10 1-1/4" X -- -- -- -- 1,4 CH-2
HEF-1 HOOD EXHAUST FAN E-103 3 3 460 4.8 PP3-8,10,12 20A-3P 3#12 1#12 3/4" X 3R 30 NF 3R 3,4 HEF-1
HEF-2 HOOD EXHAUST FAN E-103 3 3 460 4.8 PP4-8,10,12 20A-3P 3#12 1#12 3/4" X 3R 30 NF 3R 3,4 HEF-2
HEF-3 HOOD EXHAUST FAN E-103 1/6 1 115 4.4 LPB-30 20A-1P 2#12 1#12 3/4" X X 1 -- -- -- 1,2,4,5 HEF-3
EF-10 GENERAL EXHAUST FAN E-103 3 3 460 4.8 PP3-13,15,17 20A-3P 3#12 1#12 3/4" X 3R 30 NF 3R 3,4 EF-10
EF-11 GENERAL EXHAUST FAN E-103 3 3 460 4.8 PP4-13,15,17 20A-3P 3#12 1#12 3/4" X 3R 30 NF 3R 3,4 EF-11
H-1 HUMIDIFIER E-102 34 3 460 40.9 PP3-14,16,18 60A-3P 3#6 1#10 1" X -- 60 NF 3R 4 H-1
RO-1 RO SKID FOR HUMIDIFIER E-102 1/3 1 115 5.5 LPB-21 20A-1P 2#12 1#12 3/4" X X 3R -- -- -- 4,9 RO-1
GHWP-1 GLYCOL HEATING H.W. PUMP E-102 3/4 1 115 13.8 LPB-29 25A-1P 2#10 1#10 3/4" X X 3R -- -- -- 2,4,7 GHWP-1
CP-1 CLEAN STEAM COND. PUMP E-102 1/8 1 115 1.9 LPA-28 20A-1P 2#12 1#12 3/4" X X 3R -- -- -- 4,9 CP-1
RFERENCE NOTES:
1. PROVIDED WITH FACTORY MOUNTED DISCONNECT.
2. UTILIZE SPARE 20A-1P CIRCUIT BREAKER IN EXISTING PANELBOARD.
3. PROVIDE TYPE XHHW-2 CONDUCTORS BETWEEN VARIABLE FREQUENCY MOTOR CONTROLLER (VFC) AND EQUIPMENT. USE OF THHN CONDUCTORS BETWEEN PANEL AND VFC IS ACCEPTABLE.
4. PROVIDE RIGID METAL CONDUIT (RMC) CONDUIT FOR ALL POWER WIRING.
5. REFER TO DETAIL 1/E-500 FOR ADDITIONAL POWER WIRING REQUIREMENTS.
6. REFER TO DETAIL 5/E-500 FOR FREEZE STAT & FIRE ALARM FAN SHUTDOWN WIRING REQUIREMENTS
7. ROUTE BRANCH CIRCUITING THROUGH EXISTING CONTACTOR (FORMALLY USED BY HEF-1) TO ALLOW FOR BMS CONTROL. REFER TO DETAIL 4/E-500 FOR ADDITIONAL POWER WIRING REQUIREMENTS.
8. ROUTE BRANCH CIRCUITING THROUGH EXISTING CONTACTOR (FORMALLY USED BY HEF-2) TO ALLOW FOR BMS CONTROL. REFER TO DETAIL 4/E-500 FOR ADDITIONAL POWER WIRING REQUIREMENTS.
9. PROVIDE NEW U.L. LISTED 20A-1P CIRCUIT BREAKER TO MATCH EXISTING PANELBOARD CONSTRUCTION (SQUARE D) AND KAIC RATING
PANELBOARD PP3
LOCATION: FILTER ROOM PH W MAIN BUS AMP: 125A
VOLTAGE (L-L) 480 3 4 MAIN TYPE: MLO
VOLTAGE (L-N) 277 MAIN CIRCUIT BREAKER: --
MOUNTING: SURFACE FEEDER SIZE: REFER TO DRAWINGS
FED FROM: PP1A (FED FROM MCC-1) SHORT CIRCUIT RATING: 10,000 AIC
FEED THRU TYPE --
NOTES:
PANELBOARD SHALL HAVE NEMA 3R ENCLOSURE.
DESCRIPTION TRIP
AMPS POLES CKT
PHASE A
(AMPS)
PHASE B
(AMPS)
PHASE C
(AMPS) CKT POLES TRIP
AMPS DESCRIPTION
CHGP-1
20 3 1 7.6 11.0 2 3 20
MAU-1-SA-- -- 3 7.6 11.0 4 -- --
-- -- 5 7.6 11.0 6 -- --
CH-1
70 3 7 41.0 4.8 8 3 20
HEF-1-- -- 9 41.0 4.8 10 -- --
-- -- 11 41.0 4.8 12 -- --
EF-10
20 3 13 4.8 40.9 14 3 60
H-1-- -- 15 4.8 40.9 16 -- --
-- -- 17 4.8 40.9 18 -- --
SPACE 19 0.0 0.0 20 SPACE
SPACE 21 0.0 0.0 22 SPACE
SPACE 23 0.0 0.0 24 SPACE
SPACE 25 0.0 0.0 26 SPACE
SPACE 27 0.0 0.0 28 SPACE
SPACE 29 0.0 0.0 30 SPACE
TOTAL LOAD PER PHASE (AMPS) 110.1 110.1 110.1
TOTAL 3-PHASE LOAD (KVA) 91.5
TOTAL 3-PHASE LOAD (AMPS) 110.2
DEMAND FACTOR 70%
DEMAND 3-PHASE LOAD (AMPS) 77.1
PANELBOARD PP4
LOCATION: FILTER ROOM PH W MAIN BUS AMP: 125A
VOLTAGE (L-L) 480 3 4 MAIN TYPE: MLO
VOLTAGE (L-N) 277 MAIN CIRCUIT BREAKER: --
MOUNTING: SURFACE FEEDER SIZE: REFER TO DRAWINGS
FED FROM: PP2 (FED FROM MCC-2) SHORT CIRCUIT RATING: 10,000 AIC
FEED THRU TYPE --
NOTES:
PANELBOARD SHALL HAVE NEMA 3R ENCLOSURE.
DESCRIPTION TRIP
AMPS POLES CKT
PHASE A
(AMPS)
PHASE B
(AMPS)
PHASE C
(AMPS) CKT POLES TRIP
AMPS DESCRIPTION
CHGP-2
20 3 1 7.6 11.0 2 3 20
MAU-1-SB-- -- 3 7.6 11.0 4 -- --
-- -- 5 7.6 11.0 6 -- --
CH-2
70 3 7 41.0 4.8 8 3 20
HEF-2-- -- 9 41.0 4.8 10 -- --
-- -- 11 41.0 4.8 12 -- --
EF-11
20 3 13 4.8 0.0 14 SPACE
-- -- 15 4.8 0.0 16 SPACE
-- -- 17 4.8 0.0 18 SPACE
SPACE 19 0.0 0.0 20 SPACE
SPACE 21 0.0 0.0 22 SPACE
SPACE 23 0.0 0.0 24 SPACE
SPACE 25 0.0 0.0 26 SPACE
SPACE 27 0.0 0.0 28 SPACE
SPACE 29 0.0 0.0 30 SPACE
TOTAL LOAD PER PHASE (AMPS) 69.2 69.2 69.2
TOTAL 3-PHASE LOAD (KVA) 57.5
TOTAL 3-PHASE LOAD (AMPS) 69.3
DEMAND FACTOR 70%
DEMAND 3-PHASE LOAD (AMPS) 48.5
| T000 Title Sheet |
| G-000 Site Plan |
| G-001 Phasing Plan |
| 2025-03-05 Hemlock Lake - Contract Documents - Stamped |
| 2025-03-10_Hemlock_Architectural CD-A101 - SS |
| 2025-03-10_Hemlock_Architectural CD-A102- RF |
| 2025-03-10_Hemlock_Architectural CD-A103 - RF |
| 2025-03-10_Hemlock_Architectural CD-A104 - RCP |
| 2025-03-10_Hemlock_Architectural CD-A105 - Details |
| 230081.00_S100 |
| Mechanical Set_Stamped |
| M-000 |
| MD-102 |
| MD-103 |
| MD-202 |
| M-102 |
| M-103 |
| M-202 |
| M-203 |
| M-500 |
| M-501 |
| M-600 |
| M-601 |
| M-700 |
| M-701 |
| MI-000 |
| MI-600 |
| MI-601 |
| MI-602 |
| Electrical Set_Stamped |
| E-000 |
| E-000-E-000 |
| ED-102 |
| ED-102-ED-102 |
| ED-103 |
| ED-103-ED-103 |
| E-101 |
| E-101-E-101 |
| E-102 |
| E-102-E-102 |
| E-103 |
| E-103-E-103 |
| E-500 |
| E-500-E-500 |
| E-501 |
| E-501-E-501 |
| E-700 |
| E-700-E-700 |
File details come from the government source that posted it. Updated .