21-103 Addendum #1 - Combined.pdf

PDF 2 MB Posted

Attached to
Eastpointe Com. Schools-Elementary & Early Learn Bldg Improv
Solicitation number
RFP ECMS 210000002121 2
Issued by
Macomb County, Michigan

About this file

This is an Addendum #1 document for the Eastpointe Community Schools District Building Improvements project (PIA Project Number 21-103), issued on June 22, 2021, by PARTNERS in Architecture, PLC for the school district located in Eastpointe, Michigan. The project encompasses building improvements across five school locations: Early Learning Center, Bellview Elementary, Crescentwood Elementary, Forest Park Elementary, and Pleasantview Elementary. The scope includes interior renovations with focus on doors, hardware, flooring, painting, and access control preparation. Addendum #1 clarifies specifications for material finishes, door hardware sets, and glazing types; removes Toilet Room A105 work from Bellview Elementary; adds 1,740 square feet of classroom floor demolition and homogeneous vinyl tile installation at the Early Learning Center; and deletes fire-rated glass type LG-10 in favor of non-fire-rated glass type MG-11. The bid due date was June 24, 2021, at 2:00 PM. Substantial completion for corridor work is required by August 29, 2021, with all other work substantially completed by November 24, 2021.

The bid form allows contractors to submit pricing for either the total project or individual buildings separately. Base bid pricing is requested for each of the five schools, with an additive alternate for thresholds at classroom doors. The project includes five $25,000 allowances per building ($125,000 total) for electrical work related to door access control preparation and ceiling-mounted light fixtures. Door hardware specifications mandate single-manufacturer products from approved suppliers, including continuous hinges by Hager, locksets by Best, exit devices by Von Duprin, and closers by LCN. The specifications reference multiple technical drawings for door and frame types, window schedules, and finish floor plans. Contractors must comply with ADA requirements, provide a pre-installation hardware meeting with manufacturer representatives, submit detailed hardware schedules, and maintain a one-year manufacturer's warranty. A non-Iran linked business certification is required for all bidders.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Eastpointe Community Schools District Building Improvements Addendum No. 1 June 22, 2021

ADDENDUM #1

Project Name: Eastpointe Community Schools Addendum No: One (1)

Issue Date: June 22, 2021

PIA Project Number: 21-103

Project Location: Eastpointe, MI

To the Contract Documents for the Eastpointe Community Schools – District Building Improvements project.

This Addendum forms a part of the above-described Contract Documents and supersedes supplements or clarifies parts thereof to the extent defined by the terms set forth in this Addendum.

This Addendum consists of (2) typed page and the following Drawing attachments:

Documents: Specifications: Pre-bid questions & answers, Prosoco Enviro Klean KNR Cleaner cutsheet

Specifications: Architectural: 00 0200 Material Finish / Color Schedule, 00 3100 Bid Form, 08 7100 Door

Hardware

Drawings: Architectural: Bellview: A0-03 Schedules, Frame Types & Door Types, A3-01 Floor Plan, A8-01 Interior Elevations, A9-04 Finish Floor Plans – Area C Crescentwood: A0-03 Schedules, Frame Types & Door Types Forest Park: A0-03 Schedules, Frame Types & Door Types Pleasantview: A0-03 Schedules, Frame Types & Door Types

DRAWING REVISIONS

ARCHITECTURAL SPECIFICATIONS:

ITEM AS1 Specification section 00 0200 – Material Finish Schedule (Issued)

A. Descriptions, specified products, finishes, colors and locations identified.

ITEM AS2 Specification section 08 7100 – Door Hardware (Re-issued)

A. Door hardware sets and set numbers have been altered slightly.

ARCHITECTURAL DRAWINGS:

ITEM AD1 Drawing A0-03 – Schedules, Frame Types & Door Types (Re-issued – All Schools)

A. Delete type LG-10 glass.

B. Replace type LG-10 glass with type MG-11 glass (All Schools – All Locations) C. Revised door hardware sets – reference door hardware specification.

Eastpointe Community Schools

Addendum No. 1

ITEM AD2 Drawing A3-01 – Floor Plan (Revised – Bellview Elementary Only) A. Removed callout 3/A3-02 and Toilet A105 scope of work

ITEM AD3 Drawing A8-01 – Interior Elevations (Revised – Bellview Elementary Only)

A. Removed interior elevations in restroom A105 and all associated scope of work

ITEM AD4 Drawing A9-04 – Finish Floor Plans – Area C (Revised – Bellview Elementary Only)

A. Removed callout 3/A3-02 and Toilet A105 scope of work

ITEM AD5 Drawing A3-01 – Floor Plan (Not re-issued – Early Learning Center Only)

A. Add 1,740 sq ft of classroom floor demolition area.

B. Add 1,740 sq ft of new HVT floor installation area.

a. 75% field color, 25% accent color

**END OF ADDENDUM**

PARTNERS 21-103

Pre-Bid RFI(s) Addendum #1

Re: Eastpointe Community Schools – District Building Improvements

PIA Project #21-103

Response to Pre-Bid Questions – Addendum #1

1. Please advise whether Vale Doors are an acceptable substitution to specified doors.

a. Please provide base bid pricing as specified. Vale doors may be proposed as an acceptable alternate, but will not be considered for base bid.

2. Please advise whether Precision Apex 2000 exit hardware and Dorma 8900 door closers are an acceptable substitution to specified door hardware.

a. Please provide base bid pricing as specified. Precision Apex 2000 exit hardware and Dorma 8900 closers may be proposed as an acceptable alternate, but will not be considered for base bid.

3. Will contractors be responsible for removing all tack strips in hallways and to reinstall or will the school district be handling this?

a. Please provide a price to remove all tack strips prior to painting and reinstall after painting.

4. Can you provide a spec for what you’re wanting us to use to clean existing grout lines at the glazed block locations?

a. Specified product is Enviro Klean – Klean ‘N Release by Prosoco. A cutsheet has been attached to this addendum.

5. At Bellview it shows new wall tile in Toilet Room A105 - can you provide a spec?

a. All work associated with Toilet Room A105 at Bellview Elementary has been removed as a part of this addendum.

6. Glass type LG-10 is indicated to be a fire rated product but the frames/doors are not a fire labeled product. Please clarify.

a. Glass type LG-10 is deleted and replaced with glass type MG-11 as a part of this addendum – no fire rated doors, frames or hardware is to be provided.

7. The drawings indicate a glass type SG-1. Specifications do not include a glass type SG-1. Please clarify.

a. “School Guard SG4 IGU” is a laminated glass with a strengthened interlayer core ––

Ref section 2.3 of specification 08 8000 glazing.

Pre-Bid RFI(s) Addendum #1

8. Can you provide more detail regarding the access control that is to be included in our scope of work?

a. This project involves preparing new and existing door frames for future door access controls. Prepping for new and existing door access controls includes extending existing electrical circuits to door locations without existing access controls and prepping conduit in new door frames for electrified hardware. No door access control systems or hardware are included. An allowance of $25,000 per building ($125,000 total) is to be carried for work related to access control preparation.

Enviro Klean® Klean ‘N Release is a fragrance-free, all-purpose cleaner and degreaser for use on soiled stone, tile, masonry, EIFS, stucco and metal panels.

It is safe enough for use on historic preservation and restoration projects yet strong enough for new construction. Easy-to-use Klean ‘N Release is dilutable with up to 10 parts water to offer an economical and effective concentrate solution.

Klean ‘N Release can also be used on windows, bathroom tub and tile, counter tops and more.

Klean ‘N Release is a US EPA Safer Choice certified cleaner that meets the Safer Choice direct release criteria. Formulated to be safer for workers and the environment by using readily biodegradable ingredients, Klean ‘N Release contains no phosphates, hazardous solvents, or environmentally harmful surfactants. The solution also offers more positive environmental and human health characteristics than conventional cleaning formulations. Klean ‘N Release was intentionally designed to be safer for use around people, plants, lawns, pets or wildlife.

ADVANTAGES

• US EPA Safer Choice certified cleaner. Meets

Safer Choice direct release criteria.

• Meets the US EPA’s Safer Choice criteria for outdoor use.

• Cleans and degreases light-to-heavily soiled stone, tile, masonry, EIFS, stucco and much more.

• Dilutable for jobs around the home.

• Replaces a host of individual cleaning agents.

• Contains no phosphates, hazardous solvents, or environmentally harmful surfactants.

• Fragrance free. Colorant free.

• Flexible dilution with up to 10 parts water.

• Ideal for unpolished natural stone – from limestone to granite.

• Works on an enormous variety of surfaces.

• Effective cleaner for windows, bathroom tub and tile, counter tops and more.

• Easy-to-use and water-rinsable.

SAFETY INFORMATION

Always read full label and SDS for precautionary instructions before use. Use appropriate safety equipment and job-site site controls during application and handling.

24-Hour Emergency Information:

INFOTRAC at 800-535-5053

REGULATORY COMPLIANCE

VOC Compliance Enviro Klean® Klean ‘N Release Cleaner is compliant with all national, state and district VOC regulations.

NEXT GENERATION CLEANERS

Enviro Klean®

Product Data Sheet • Page 1 of 3 • Item #41071 – 121120 • ©2020 PROSOCO, Inc. • www.prosoco.com

Klean ‘N Release Cleaner

Nonfood Compounds Program Listed A1 and A4

Registration #159235

TYPICAL TECHNICAL DATA

FORM Clear liquid, mild odor

SPECIFIC GRAVITY 1.05

pH 10.90

WT/GAL 8.70 lbs

ACTIVE CONTENT not applicable

TOTAL SOLIDS not applicable

VOC CONTENT <0.1%

FLASH POINT >212° F (>100° C)

ASTM D3278

FREEZE POINT 32° F (0° C)

SHELF LIFE 2 years in tightly sealed, unopened container

PREPARATION

Before use, test all substrates not intended to be cleaned with Klean ‘N Release. If testing indicates adverse effects, the substrate must be protected before full scale application. Best practices are to protect people, vehicles, property, metal, painted surfaces, plants and other non-target materials from product, splash, residue, wind drift and fumes.

Surface and Air Temperatures Best air and surface temperatures for cleaning are 50° F (10° C) or above. Cleaning when temperatures are below freezing or will be overnight may harm masonry. If freezing conditions exist before application, allow masonry to thaw before application.

Equipment Apply with low-pressure sprayer, brush or heavy nap roller. Scrub heavily soiled surfaces with a nonabrasive brush or synthetic scrubbing pad.

Rinse with enough water and pressure to flush spent cleaner and dissolved soiling from the masonry surface and surface pores without damage. Masonry-washing equipment generating 400–1000 psi with a water flow rate of 6–8 gpm is the best water/pressure combination for rinsing porous masonry. Use a 15–45° fan spray tip. Heated water (150–180°F; 65–82°C) may improve cleaning efficiency.

Use adjustable equipment for reducing water flow rates and rinsing pressure for sensitive surfaces.

Rinsing pressures greater than 1000 psi and fan spray tips smaller than 15° may permanently damage sensitive masonry. Water flow rates less than 6 gpm may reduce cleaning productivity and contribute to uneven cleaning results.

Storage and Handling Store in a cool, dry place. Always seal container after dispensing. Do not alter or mix with other chemicals. Published shelf life assumes upright storage of factory-sealed containers in a dry place.

Maintain temperature of 45–100°F (7–38°C). If product freezes, allow to thaw and mix well. Do not double stack pallets. For unused material, dispose of in accordance with local, state and federal regulations.

APPLICATION

Read “Preparation” and the Safety Data Sheet before use. ALWAYS TEST a small area of each surface to confirm suitability, coverage rate and desired results before beginning overall application. Test with the same equipment, recommended surface preparation and application procedures planned for general application. Let surface dry thoroughly before inspection.

Dilution & Mixing Do not alter or use for purposes other than specified. Dilute with up to 10 parts fresh water.

Use in concentrate to remove heavy soiling. Always test to final dilution producing desired cleaning results.

Application Instructions

1. Working from the bottom to the top, prewet the surface with clean water.

2. Apply the cleaner to the surface using a brush or low-pressure spray.

3. Let the cleaner dwell on the surface 1–10 minutes, based on testing. Gently scrub heavily soiled areas. NOTE: Do not let the cleaner dry on the surface. If drying occurs, lightly wet surfaces with fresh water and reapply in a gentle scrubbing manner.

4. Working from the bottom to the top, rinse the surface thoroughly with clean water.

5. Repeat steps 1 through 4 if necessary.

Cleanup Clean tools and equipment with fresh water.

Product Data Sheet Enviro Klean® Klean ‘N Release Cleaner

Product Data Sheet • Page 2 of 3 • Item #41071 – 121120 • ©2020 PROSOCO, Inc. • www.prosoco.com

WARRANTY

The information and recommendations made are based on our own research and the research of others, and are believed to be accurate. However, no guarantee of their accuracy is made because we cannot cover every possible application of our products, nor anticipate every variation encountered in masonry surfaces, job conditions and methods used. The purchasers shall make their own tests to determine the suitability of such products for a particular purpose.

PROSOCO, Inc. warrants this product to be free from defects. Where permitted by law, PROSOCO makes no other warranties with respect to this product, express or implied, including without limitation the implied warranties of merchantability or fitness for particular purpose.

The purchaser shall be responsible to make his own tests to determine the suitability of this product for his particular purpose. PROSOCO’s liability shall be limited in all events to supplying sufficient product to re-treat the specific areas to which defective product has been applied. Acceptance and use of this product absolves PROSOCO from any other liability, from whatever source, including liability for incidental, consequential or resultant damages whether due to breach of warranty, negligence or strict liability. This warranty may not be modified or extended by representatives of PROSOCO, its distributors or dealers.

CUSTOMER CARE

Factory personnel are available for product, environment and job-safety assistance with no obligation. Call 800-255-4255 and ask for Customer Care – technical support.

Factory-trained representatives are established in principal cities throughout the continental United States. Call Customer Care at 800-255-4255, or visit our website at www.prosoco.com, for the name of the PROSOCO representative in your area.

Product Data Sheet Enviro Klean® Klean ‘N Release Cleaner

Product Data Sheet • Page 3 of 3 • Item #41071 – 121120 • ©2020 PROSOCO, Inc. • www.prosoco.com

BEST PRACTICES

Apply with low-pressure sprayer, brush or heavy nap roller. Scrub heavily soiled surfaces with a nonabrasive brush or synthetic scrubbing pad.

Rinse with enough water and pressure to flush spent cleaner and dissolved soiling from the masonry surface and surface pores without damage. Masonry-washing equipment generating 400–1000 psi with a water flow rate of 6–8 gpm is the best water/pressure combination for rinsing porous masonry. Use a 15–45° fan spray tip.

Heated water may improve cleaning efficiency.

Do not let Klean ‘N Release dry on the surface.

If drying occurs, lightly wet surfaces with fresh water and reapply in a gentle scrubbing manner.

Never go it alone. If you have problems or questions, contact your local PROSOCO distributor or field representative. Or call PROSOCO technical Customer Care at 800-255- 4255.

MATERIAL FINISH / COLOR SCHEDULE PARTNERS 19-128

MATERIAL SCHEDULE

000200-1

Spec

Section

Item Description Product Specified Finish / Color Location (refer to drawings for exact locations)

042000

Mortar (FB-1) SGS Solomon Color: To be selected by Architect

079200

Sealant at Face Brick Custom Match to each face brick type

Sealant at Masonry Block Custom Match to each Masonry

Block type

081416

WD-1 Pre-finished Wood Door Masonite Architectural -

Aspiro Series

Finish / Color: To be selected by architect

ELC office entrance door

084113

PT-1 Storefront System As Specified Color: Factory finish to be selected by architect

Exterior Doors

084115

FRP-1 FRP Door and Door Frame Special-Lite, Flush Door SL-

Color: To be selected by Architect Exterior Doors

FLUSH WOOD DOORS

FIBERGLASS REINFORCED POLYSTER (FRP) DOOR

UNIT MASONRY

ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

JOINT SEALANTS

APRIL 20, 2021 / BIDDING - CONSTRUCTION

000200-2

Spec

Section

Item Description Product Specified Finish / Color Location (refer to drawings for exact locations)

UNIT MASONRY

095123

ACT-1 Acoustical Ceiling Tile Armstrong - Tectum - Finale -beveled edges on long sides, square edges on short sides

Color: White Refer to room finish schedule

ACOUSTICAL TILE CEILINGS

000200-3

Spec

Section

Item Description Product Specified Finish / Color Location (refer to drawings for exact locations)

UNIT MASONRY 096513

RB-1 Resilient Base ROPPE. - 4" Vinyl Wall Base Color: 100 Black Refer to room finish schedule

RA-1 Rubber Accessories ROPPE. - Adapter &

Transitions, #33 Threshold

Color:100 Black

096519

HVT-1 Homogeneous Vinyl Tile TOLI FasolPlus - 17.7" x 17.7" x 0.120" - Square Edge -

Smooth

Color: Pebble 2061 Ref enlarged finish floor plans

HVT-2 Homogeneous Vinyl Tile TOLI FasolPlus - 17.7" x 17.7" x 0.120" - Square Edge -

Smooth

Color: Thicket 2077 Ref enlarged finish floor plans

HVT-3 Homogeneous Vinyl Tile TOLI FasolPlus - 17.7" x 17.7" x 0.120" - Square Edge -

Smooth

Color: Latte 2042 Ref enlarged finish floor plans

HVT-4 Homogeneous Vinyl Tile TOLI FasolPlus - 17.7" x 17.7" x 0.120" - Square Edge -

Smooth

Color: Taupe 2062 Ref enlarged finish floor plans

HVT-5 Homogeneous Vinyl Tile TOLI FasolPlus - 17.7" x 17.7" x 0.120" - Square Edge -

Smooth

Color: Mineral 2074 Ref enlarged finish floor plans

HVT-6 Homogeneous Vinyl Tile TOLI FasolPlus - 17.7" x 17.7" x 0.120" - Square Edge -

Smooth

Color: Spice 2026 Ref enlarged finish floor plans

RESILIENT TILE FLOORING

RESILIENT BASE AND ACCESSORIES

000200-4

Spec

Section

Item Description Product Specified Finish / Color Location (refer to drawings for exact locations)

UNIT MASONRY 096813

CPT-1 Walk-Off Carpet Shaw Color: Vestibules

099123

PNT-1 Paint Sherwin Williams Color: SW Field Color

TILE CARPETING

INTERIOR PAINTING

BID FORM

011000 - 1

JUNE 22, 2021 / ADDENDUM #1

BID PROPOSAL FOR: ECS – DISTRICT BUILDING IMPROVEMENTS PROJECT

SEND BID TO: Eastpointe Community Schools - Administration Building

24685 Kelly Rd.

Eastpointe, MI 48021 robert.carlesso@eastpointeschools.org

BID DUE DATE: JUNE 24, 2021; 2:00PM

BIDDERS NAME: ______________________________________________________________________

We have examined the Contract Documents for the proposed project as prepared by PARTNERS in Architecture, PLC.

In accordance therewith, the undersigned proposes to furnish all labor and materials for construction as set forth in the Contract Documents, including the following Addenda, if any (fill in the addenda number, thus confirming receipt):

Addendum Number ________ Addendum Number ________ Addendum Number ________

1. Accompanying the proposal is a bid security for work required to be furnished by the Contract Documents, the same being subject to forfeiture in the event of default by the undersigned.

2. I agree to complete the Project, by the dates listed in Specification Section 011000 – Summary; provided that a notice to proceed is issued within thirty (30) days.

3. I understand that the Owner reserves the right to reject any or all bids, and it is agreed that this bid may not be withdrawn for a period of sixty (60) days from the opening thereof.

5. Attached herewith are the documents requested in the Supplementary Instructions to Bidders, Specification Section

002213, paragraph 4.3.5.

A. BASE BID – Total Project – Assumes all work at all five buildings are approved:

(Insert a base bid amount in the blank provided).

__________________________________________________Dollars $___________________

PROVIDE INDIVIDUAL PRICING – Assumes Individual Buildings Can be Awarded Separately

1. BASE BID – Early Learning Center: (Insert a base bid amount in the blank provided).

__________________________________________________Dollars $__________________

2. BASE BID – Bellview Elementary School: (Insert a base bid amount in the blank provided).

3. BASE BID – Crescentwood Elem. School: (Insert a base bid amount in the blank provided).

011000 - 2

4. BASE BID – Forest Park Elem. School: (Insert a base bid amount in the blank provided).

5. BASE BID – Pleasantview Elem. School: (Insert a base bid amount in the blank provided).

B. SCHEDULE: Substantial Completion – Corridor Work: no later than August 29, 2021.

Substantial Completion – All other Work: no later than November 24, 2021.

C. ALTERNATES: Refer to Specification Section 012300.

Additive Alternate #1: Thresholds at Doors to Classrooms: ____________________________________

D. ALLOWANCES:

Bellview: Electrical work re: door access control prep & ceiling mounted light fixtures: $25,000

Crescentwood: Electrical work re: door access control prep & ceiling mounted light fixtures: $25,000

Forest Park: Electrical work re: door access control prep & ceiling mounted light fixtures: $25,000

Pleasantview: Electrical work re: door access control prep & ceiling mounted light fixtures: $25,000

ELC: Electrical work re: door access control prep & ceiling mounted light fixtures: $25,000

E. NON-IRAN LINKED BUSINESSES

By signing below, I certify and agree on behalf of myself and the company submitting this proposal the following: (1) that I am duly authorized to legally bind the company submitting this proposal; and

(2) that the company submitting this proposal is not an “Iran linked business,” as that term is defined in Section 2(e) of the Iran Economic Sanctions Act, being Michigan Public Act No. 517 of 2012; and

(3) that I and the company submitting this proposal will immediately comply with any further certifications or information submissions requested by the City in this regard.

011000 - 3

F. COMPANY / CONTACT INFORMATION

Company Name:_____________________________________________________________

Contact Name:______________________________________________________________

Address:___________________________________________________________________

Phone Number: _______________________ Cell Number: __________________________

Email: _____________________________________________________________________

Corporate Officer Name:_____________________________Title_______________________

Corporate Officer Signature:_____________________________ Date:__________________

Federal ID Number : __________________

END OF BID FORM

DOOR HARDWARE

087100 - 1

SECTION 087100 – DOOR HARDWARE

PART 1 - GENERAL

1.1 Refer to "General and Special Conditions", and "Instructions to Bidders", Division 1 of Specifications.

Requirements of these Sections and the project drawings shall govern work in this section.

1.2 Work Included:

A. Furnish all items of Finish Hardware specified, scheduled, shown or required herein except those items specifically excluded from this section of the specification.

B. Related work:

1. Division 00 00 00 – Procurement and Contracting Requirements

2. Division 01 00 00 – General Requirements

3. Division 06 00 00 – Wood, Plastics, and Composites

4. Division 08 00 00 – Openings

5. Division 10 00 00 – Specialties

6. Division 11 00 00 – Equipment

7. Division 26 00 00 – Electrical

8. Division 27 00 00 – Communications

9. Division 28 00 00 – Electronic Safety and Security

C. Specific Omissions: Hardware for the following is specified or indicated elsewhere, unless specifically listed in the hardware sets:

1. Cabinet Hardware.

2. Signs, except as noted.

3. Folding partitions, except cylinders where detailed.

4. Sliding aluminum doors

5. Chain link and wire mesh doors and gates

6. Access doors and panels

7. Overhead and Coiling doors

1.3 Quality Assurance

A. Requirements of Regulatory Agencies:

1. Furnish finish hardware to comply with the requirements of laws, codes, ordinances, and regulations of the governmental authorities having jurisdiction where such requirements exceed the requirements of the Specifications.

2. Furnish finish hardware to comply with the requirements of the regulations for public building accommodations for physically handicapped persons of the governmental authority having jurisdiction and to comply with Americans with Disabilities Act.

087100 - 2

3. Provide hardware for fire-rated openings in compliance with NFPA 80 and state and local building code requirements. Provide only hardware that has been tested and listed by UL for types and sizes of doors required and complies with requirements of door and door frame labels.

B. Hardware Supplier:

1. Shall be an established firm dealing in contract builders’ hardware. He must have adequate inventory, qualified personnel on staff and be located within 100 miles of the project. The distributor must be a factory-authorized dealer for all materials required. The hardware supplier shall be a corporate member in good standing of The Door and Hardware Institute (DHI), employing at least one Architectural Hardware Consultant (AHC) who is currently participating in DHI’s continuing education program (CEP).

C. Electrified Door Hardware Supplier:

1. Shall be an experienced door hardware supplier who has completed projects with electrified door hardware similar in material, design, and extent to that indicated for this project, whose work has resulted in construction with a record of successful in-service performance, and who is acceptable to manufacturer of primary materials.

2. Shall prepare data for electrified door hardware, including shop drawings, based on testing and engineering analysis of manufacturer’s standard units in assemblies similar to those indicated for this project.

3. Shall have experience in providing consulting services for electrified door hardware installations.

D. Pre-installation Meeting:

1. Before hardware installation, General Contractor/Construction Manager will request a hardware installation meeting be conducted on the installation of hardware; specifically that of locksets, closers, exit devices, overhead stops and coordinators. Manufacturer's representatives of the above products, in conjunction with the hardware supplier for the project, shall conduct the meeting.

Meeting to be held at job site and attended by installers of hardware for aluminum, hollow metal and wood doors. Meeting to address proper coordination and installation of hardware, per finish hardware schedule for this specific project, by using installation manuals, hardware schedule, templates, physical product samples and installation videos.

2. When any electrical or pneumatic hardware is specified this meeting shall also include the following trades/installers: Electrical, Security, Alarm systems and Architect.

3. Convene one week or more prior to commencing work of this Section.

4. The Hardware Supplier shall include the cost of this meeting in his proposal.

E. Manufacturer:

1. Obtain each type of hardware (latch and locksets, hinges, closers, etc.) from a single manufacturer, although several may be indicated as offering products complying with requirements.

2. Provide electrified door hardware from same manufacturer as mechanical door hardware, unless otherwise indicated.

1.4 Submittals:

A. Hardware Schedule

087100 - 3

1. Submit number of Hardware Schedules as directed in Division 1.

2. Follow guidelines established in Door & Hardware Institute Handbook (DHI) Sequence and Format for the Hardware Schedule unless noted otherwise.

3. Schedule will include the following:

a. Door Index including opening numbers and the assigned Finish Hardware set.

b. Preface sheet listing category only and manufacturer's names of items being furnished as follows:

CATEGORY SPECIFIED SCHEDULED

Hinges Manufacturer A Manufacturer B

Lock sets Manufacturer X Manufacturer X

Kick Plates Open Manufacturer Z

c. Hardware Locations: Refer to Article 3.1 B.2 Locations.

d. Opening Description: Single or pair, number, room locations, hand, active leaf, degree of swing, size, door material, frame material, and UL listing.

e. Hardware Description: Quantity, category, product number, fasteners, and finish.

f. Headings that refer to the specified Hardware Set Numbers.

g. Scheduling Sequence shown in Hardware Sets.

h. Product data of each hardware item, and shop drawings where required, for special conditions and specialty hardware.

i. Electrified Hardware system operation description.

j. "Vertical" scheduling format only. "Horizontal" schedules will be returned "Not Approved."

k. Typed Copy.

l. Double-Spacing.

m. 8-1/2 x 11 inch sheets

n. U.S. Standard Finish symbols or BHMA Finish symbols.

B. Product Data:

1. Submit, in booklet form Manufacturers Catalog cut sheets of scheduled hardware.

2. Submit product data with hardware schedule.

C. Samples:

1. Prior to submittal of the final hardware schedule and prior to final ordering of finish hardware, submit one sample, if required, of each type of exposed hardware unit, finished as required and tagged with full description for coordination with schedule.

2. Samples will be returned to the supplier. Units, which are acceptable and remain undamaged through submittal, review and field comparison procedures may, after final check of operation, be used in the work, within limitations of keying coordination requirements.

D. Key Schedule:

1. All final cylinder cores and keying by owner.

E. Electrified Hardware Drawings:

1. Submit elevation drawings showing relationship of all electrical hardware components to door and frame. Indicate number and gage of wires required.

a. Include wiring drawing showing point to point wire hook up for all components.

087100 - 4

b. Include system operations descriptions for each type of opening; describe each possible condition.

F. Submit to General Contractor/Construction Manager, the factory order acknowledgement numbers for the various hardware items to be used on the project. The factory order acknowledgement numbers shall help to facilitate and expedite any service that may be required on a particular hardware item. General Contractor/Construction Manager shall keep these order acknowledgement numbers on file in the construction trailer.

1.5 Product Delivery, Storage, and Handling:

A. Label each item of hardware with the appropriate door number and Hardware Schedule heading number, and deliver to the installer so designated by the contractor.

1.6 Existing Conditions:

A. Where existing doors, frames and/or hardware are to remain, conditions, preparations and functions shall be field verified to confirm compatibility with specified hardware. Where any incompatibility is discovered, notify the contractor or construction manager immediately and provide a suggested solution based on industry standard business practices.

1.7 Warranties:

A. Refer to Division 1 for warranty requirements.

B. Special Warranty Periods:

1. All items shall carry a minimum manufacturer's 1-year warranty against manufacturing defects and workmanship. Full manufacturer’s warranty for individual products shall apply.

C. During the warranty period, replace defective work, including labor, materials and other costs incidental to the work.

PART 2 - PRODUCT

2.1 Furnish each category with the products of only one manufacturer unless specified otherwise; this requirement is mandatory whether various manufacturers are listed or not.

2.2 Provide the products of manufacturer designated or if more than one manufacturer is listed, the comparable product of one of the other manufacturers listed. Where only one manufacturer or product is listed, it is understood that this is the owner’s Building Standard and "no substitution" is allowed.

A. Hinges:

087100 - 5

1. Templates: Except for hinges and pivots to be installed entirely (both leaves) into wood doors and frames, provide only template-produced units.

2. Screws: Provide Phillips flat-head screws complying with the following requirements:

a. For metal doors and frames install machine screws into drilled and tapped holes.

b. For wood doors and frames install wood screws.

c. For fire-rated wood doors install #12 x 1-1/4-inch, threaded-to-the-head steel wood screws.

d. Finish screw heads to match surface of hinges or pivots.

3. Hinge Pins: Except as otherwise indicated, provide hinge pins as follows:

a. Out-Swing Exterior Doors: Nonremovable pins.

b. Tips: Flat button and matching plug, finished to match leaves.

4. Number of Hinges: Provide number of hinges indicated but not less than 3 hinges per door leaf for doors 90 inches or less in height and one additional hinge for each 30 inches of additional height.

a. Fire-Rated Doors: Not less than 3 hinges per door leaf for doors 86 inches or less in height with same rule for additional hinges.

5. Approved Manufacturers: Subject to compliance with requirements, provide product indicated on schedule or equal product by one of the following:

a. Stanley

b. Hager

c. Ives

d. McKinney

e. No alternate manufacturers will be accepted without architect’s approval prior to bidding.

B. Continuous Gear Hinge:

1. 6063-T6 aluminum alloy, anodized finish (cap on entire hinge painted if specified). Manufacture to template, uncut hinges non-handed, pinless assembly, three interlocking extrusions, full height of door and frame, lubricated polyacetal thrust bearing, fasteners 410 stainless steel plated and hardened. All hinge profiles to be manufactured to template bearing locations, with standard duty bearing configurations at 5-1/8” spacing with a minimum of 16 bearings: and heavy duty at 2-9/16” spacing with a minimum of 32 bearings. Anodizing of material shall be done after fabrication of components so that all bearing slots are anodized.

2. Length: 1" less than door opening height. Fastener 12-24 x 1/2" #3 Phillips keen form stainless steel self-tapping at aluminum and hollow metal doors, 12- 1/2" #3 Philips, flathead full thread at wood doors.

3. Furnish fire rated hinges "FR" at labeled openings.

4. Approved Manufacturers: Subject to compliance with requirements, provide product indicated on schedule or equal product by one of the following:

a. Ives

b. Hager

c. Select

d. No alternate manufacturers will be accepted without architect’s approval prior to bidding.

C. Locksets and Latchsets - Mortise Type:

1. Locksets shall be manufactured from heavy gauge steel, minimum lockcase thickness 1/8”, containing components of steel with a zinc dichromate plating for corrosion resistance.

2. Locks are to have a standard 2 ¾” backset with a full ¾” throw two-piece stainless steel mechanical anti-friction latchbolt. Deadbolt shall be a full 1” throw, constructed of stainless steel.

087100 - 6

3. Lockcase shall be easily handed without chassis disassembly by removing handing screw on lockcase and installing in opposite location on reverse side. Changing of door hand bevel from standard to reverse hand shall be done by removing the lockcase scalp plate, and pulling and rotating the latchbolt 180 degrees.

4. Lock trim shall be through-bolted to the door to assure correct alignment and proper operation. Lever trim shall have external spring cage mechanism to assist in support of the lever weight. Thumb turns shall be able to be turned without tight grasping and twisting.

5. Approved Manufacturer:

a. Best 45H Series.

b. No substitutions will be accepted (per owner’s standard).

6. Provide strikes with extended lips where required to protect trim from being marred by latch bolt.

Provide strike lips that do not project more than 1/8" beyond door frame trim at single doors and have 7/8" lip to center at pairs of 1-3/4" doors.

D. Exit Devices:

1. Exit devices shall be touchpad style, fabricated of brass, bronze, stainless steel, or aluminum, plated to the standard architectural finishes to match the balance of the door hardware.

2. All exit devices shall incorporate a fluid damper, which decelerates the touchpad on its return stroke and eliminates noise associated with exit device operation. Touchpad shall extend a minimum of one half of the door width. All latchbolts to be deadlatching type, with a self-lubricating coating to reduce wear.

3. End-cap will be sloped to deflect any impact from carts and they shall be flush with the external mechanism case. End caps that overlap and project above the mechanism case are unacceptable.

End cap shall utilize a two-point attachment to the mounting bracket.

4. Touchpad shall match exit device finish, and shall be stainless steel for US26, US26D, US28, US32, and US32D finishes. Only compression springs will be used in devices, latches, and outside trims or controls.

5. Plastic templates shall be included with each exit device to facilitate a quick, easy and accurate installation.

6. Strikes shall be roller type and come complete with a locking plate to prevent movement.

7. All rim and vertical rod exit devices shall have passed a 5 million(5,000,000) cycle test based on

ANSI A156.3, 1994, Grade 1 test standards and certified by an independent testing lab.

8. All mortise exit devices shall have passed a 10 million(10,000,000)cycle test based on ANSI A156.3, 1994, Grade 1 test standards and certified by an independent testing lab.

9. Provide cylinder dogging on panic exit hardware where noted in hardware sets.

10. Exit devices shall be UL listed panic exit hardware. All exit devices for fire rated openings shall be

UL labeled fire exit hardware.

11. Lever trim for exit devices shall be vandal-resistant type, which will travel to a 90-degree down position when more than 35 pounds of torque are applied, and which can easily be re-set.

12. Approved Manufacturers: Subject to compliance with requirements, provide product indicated on schedule or equal product by one of the following:

a. Von Duprin

b. No alternate manufacturers will be accepted without architect’s approval prior to bidding.

13. Trim:

a. As specified in sets.

b. Levers to match lockset design where specified.

E. Push and Pull Hardware:

087100 - 7

1. Push Plates: Ives 8200 Series 4 x 16 x .050 inches.

2. Pull Plates: Ives 8302-8 4 x 16 x .050 inches. 8” center.

3. Vandal Resistant Pulls: Ives VR900 Series. Stainless steel construction 0.120 inches thick.

4. Approved Manufacturers: Subject to compliance with requirements, provide product indicated on schedule or equal product by one of the following:

a. Rockwood

b. Hager

c. Ives

d. No alternate manufacturers will be accepted without architect’s approval prior to bidding.

F. Closers:

1. Provide ANSI A156.4, Grade 1 door closers with 10-year warranty against defects in materials and workmanship.

2. Provide multi-sized closers, handing required, with spring power adjustment. Adjustment range to be from size 1 thru size 5, to suit ADA requirements.

3. Provide all necessary mounting brackets, drop plates, parallel arm brackets, and/or adjustable length arms to permit installation of door closers opposite of the corridor or hall side wherever possible.

Supplier to indicate on his schedule the type of mounting to be used for each application.

4. Closers shall have individual non-critical adjustment valves for door speed, latching speed, and backcheck control.

5. Provide with high impact, non-corrosive covers that completely conceal all valves to discourage tampering.

6. Refer to door and frame details and furnish accessories such as drop plates, panel adapters, spacers and supports as required to correctly install door closers. State degree of door swing in the hardware schedule.

7. Approved Manufacturers: Subject to compliance with requirements, provide product indicated on schedule or equal product by one of the following:

a. LCN 4040XP Series

b. Norton 9500 Series.

c. No alternate manufacturers will be accepted without architect’s approval prior to bidding.

G. Overhead Holders and Stops:

1. Type, function and fasteners must be same as Glynn-Johnson specified. Size per manufacturer's selector chart. Plastic end caps, hold open mechanisms and shock blocks are not allowed. End caps must be finished same as balance of unit.

2. Manufacture products using base material of Brass/Bronze for US3, US4, & US10B finished products and 300 Stainless Steel for US32 & US32D finished products.

3. Approved Manufacturers: Subject to compliance with requirements, provide product indicated on schedule or equal product by one of the following:

a. Glynn Johnson

b. Sargent

c. Rixson

d. No alternate manufacturers will be accepted without architect’s approval prior to bidding.

H. Kick Plates:

087100 - 8

1. Furnish .050 inches thick, beveled four sides, countersunk fasteners, 10" high x door width less 1- 1/2" at single doors and less 1" at pairs. Where glass or louvers prevent this height, supply with height equal to height of bottom rail less 2”.

2. Any BHMA manufacturing product meeting above is acceptable.

I. Armor Plates:

1. Provide .050 inches thick, B4E, countersunk fasteners, 36" x door width less 1-1/2” at single doors and 1” less door width at pairs. At exit devices provide height to bottom of exit device cases. At locksets, latchsets, or push pull latches, cut for rose or escutcheon. Bevel all edges of all plates.

J. Wall Stops:

1. Length to exceed projection of all other hardware. Provide with threaded studs and expansion shields for masonry wall construction. Install with slope at top.

2. Approved Manufacturers: Subject to compliance with requirements, provide product indicated on schedule or equal product by one of the following:

a. Ives

b. Rockwood

c. Hager

d. No alternate manufacturers will be accepted without architect’s approval prior to bidding.

K. Thresholds:

1. 1/2" high - 5" wide, unless noted otherwise. Cope at jambs.

2. Furnish full wall opening width when frames are recessed.

3. Cope in front of mullions if thresholds project beyond door faces.

4. Furnish with non-ferrous Stainless Steel Screws and Lead Anchors.

5. Approved Manufacturers: Subject to compliance with requirements, provide product indicated on schedule or equal product by one of the following:

a. Hager

b. NGP

c. Pemko

d. Zero

e. No alternate manufacturers will be accepted without architect’s approval prior to bidding.

L. Door Sweeps:

1. Surface Sweeps:

2. Approved Manufacturers: Subject to compliance with requirements, provide product indicated on schedule or equal product by one of the following:

a. Hager

b. NGP

c. Pemko

d. Zero

e. No alternate manufacturers will be accepted without architect’s approval prior to bidding.

087100 - 9

M. Miscellaneous:

1. Furnish items not categorized in the above descriptions but specified by manufacturer’s names in Hardware Sets.

N. Fasteners:

1. Furnish fasteners of the proper type, size, quantity and finish. Use machine screws and expansion shields for attaching hardware to concrete or masonry, and wall grip inserts at hollow wall construction. Furnish machine screws for attachment to reinforced hollow metal doors and frames and reinforced aluminum doors and frames. Furnish full thread wood screws for attachment to solid wood doors and frames. "TEK" type screws are not acceptable.

2. Sex bolts will not be permitted on reinforced metal doors or wood doors where blocking is specified.

2.3 Finishes:

A. Generally, Dull Chrome, US26D / BHMA 626. Provide finish for each item as indicated in sets.

2.4 Templates and Hardware Location:

A. Furnish hardware made to template. Supply required templates and hardware locations to the door and frame manufacturers.

B. Furnish metal template to frame/door supplier for continuous hinge.

C. Refer to Article 3.1 B.2, Locations, and coordinate with templates.

2.5 Cylinders and Keying:

A. Key to existing Best key system. Verify requirements with Owner.

B. Provided (10) master keys, (1) additional cut key per lock, visual key control, do not duplicate.

C. Provide construction cores for use during construction period. Provide (10) construction keys.

PART 3 - EXECUTION

3.1 Installation

A. General:

1. Install hardware according to manufacturers installations and template dimensions. Attach all items of finish hardware to doors, frames, walls, etc. with fasteners furnished and required by the manufacture of the item.

2. Provide blocking/reinforcement for all wall mounted Hardware.

087100 - 10

3. Reinforced hollow metal doors and frames and reinforced aluminum door and frames will be drilled and tapped for machine screws.

4. Solid wood doors and frames: full thread wood screws. Drill pilot holes before inserting screws.

5. Continuous gear hinges attached to hollow metal doors and frames and aluminum doors and frames:

12-24 x 1/2" #3 Phillips Keenform self-tapping. Use #13 or 3/16 drill for pilot.

6. Continuous Gear Hinges require continuous mortar guards of foam or cardboard 1/2" thick x frame height, applied with construction adhesive.

7. Install weather-strip gasket prior to parallel arm closer bracket, rim exit device or any stop mounted hardware. Gasket to provide a continuous seal around perimeter of door opening. Allow for gasket when installing finish hardware. Door closers will require special templating. Exit devices will require adjustment in backset.

B. Locations:

1. Dimensions are from finish floor to center line of items.

2. Include this list in Hardware Schedule.

CATEGORY DIMENSION

Hinges Door Manufacturer's Standard Levers Door Manufacturer's Standard Exit Device Touchbar Per Template Push Plates 52" Pull Plates 42" Wall Stops/Holders At Head

C. Field Quality Inspection:

1. Inspect material furnished, its installation and adjustment, and instruct the Owner's personnel in adjustment, care and maintenance of hardware.

2. Locksets and exit devices shall be inspected after installation and after the HVAC system is in operation and balanced, to insure correct installation and proper operation.

3. Closers shall be inspected and adjusted after the HVAC system is in operation and balanced, to insure correct installation and proper operation.

4. A written report stating compliance, and also locations and kinds of noncompliance shall be forwarded to the Architect with copies to the Contractor, hardware distributor, hardware installer and building owner.

D. Technical and Warranty Information:

1. At the completion of the project, the technical and warranty information coalesced and kept on file by the General Contractor/Construction Manager shall be given to the Owner or Owner’s Agent. In addition to both the technical and warranty information, all factory order acknowledgement numbers supplied to the General Contractor/Construction Manager during the construction period shall be given to the Owner or Owner’s Agent. The warranty information and factory order acknowledgement numbers shall serve to both expedite and properly execute any warranty work that may be required on the various hardware items supplied on the project.

2. Submit to General Contractor/Construction Manager, two copies each of parts and service manuals and two each of any special installation or adjustment tools. Include for locksets, exit devices, door closers and any electrical products.

087100 - 11

3. Fire-Rated Door Assemblies: Where fire-rated door assemblies are indicated, provide door hardware rated for use in assemblies complying with NFPA 80 that are listed and labeled by a qualified testing agency, for fire-protection ratings indicated, based on testing at positive pressure according to NFPA 252 or UL 10C, unless otherwise indicated. Provide positive latching and self closing, regardless if specified in sets.

4. Items of hardware not definitely specified herein but necessary for completion of the work shall be provided. Such items shall be of type and quality suitable to the service required and comparable to the adjacent hardware. Where size and shape of members is such as to prevent the use of types specified, hardware shall be furnished of suitable types having as nearly as practicable the same operation and quality as the type specified. Sizes shall be adequate for the service required.

5. Include such nuances as strike type, strike lip length, raised barrel hinges, mounting brackets, blade stop spacers, special templates, fasteners, shims, and coordination between conflicting products.

All doors shall be provided with a stop.

3.2 Hardware Sets:

BELLVIEW ELEMENTARY:

SET 01

1 EA CONTINUOUS HINGE 780-224HD x EPT PREP CLR HAGER

1 EA CONTINUOUS HINGE 780-224HD CLR HAGER

1 EA POWER TRANSFER EPT-10 SP28 VON DUPRIN

1 EA RIM EXIT DEVICE HD-QEL 99 NL-OP 626 VON DUPRIN

1 EA RIM EXIT DEVICE 99 EO 626 VON DUPRIN

1 EA CYLINDER AS REQUIRED 626 BEST

2 EA OFFSET PULL BF158 630 ROCKWOOD

1 EA POWER SUPPLY PS902 x 900-2RS GRY VON DUPRIN

2 EA CLOSER 4040XP EDA 689 LCN

2 EA OVERHEAD STOP 100 SERIES 630 GJ

2 EA WEATHERSTRIP 160SA AL NGP

2 EA SWEEP 200NA AL NGP

2 EA THRESHOLD 8425 MIL NGP

1 EA CARD READER RE-USE EXISTING

* OPERATIONAL DESCRIPTION: DOORS NORMALLY CLOSED AND LOCKED. VALID CREDENTIAL ALLOWS

ENTRY THROUGH (1) DOOR. DOORS REMAIN LOCKED UPON LOSS OF POWER. INSIDE PUSH PADS

ALWAYS FREE FOR EGRESS.

SET 01A

2 EA CONTINUOUS HINGE 780-224HD x EPT PREP CLR HAGER

2 EA POWER TRANSFER EPT-10 SP28 VON DUPRIN

1 EA RIM EXIT DEVICE HD-QEL 99 NL-OP 626 VON DUPRIN

1 EA RIM EXIT DEVICE HD-QEL 99 EO 626 VON DUPRIN

1 EA CYLINDER AS REQUIRED 626 BEST

2 EA OFFSET PULL BF158 630 ROCKWOOD

1 EA POWER SUPPLY PS902 x 900-2RS GRY VON DUPRIN

1 EA AUTOMATIC OPERATOR BY OTHER SECTION

2 EA ACTUATOR BY OTHER SECTION

1 EA CLOSER 4040XP EDA 689 LCN

087100 - 12

2 EA OVERHEAD STOP 100 SERIES 630 GJ

2 EA WEATHERSTRIP 160SA AL NGP

2 EA SWEEP 200NA AL NGP

2 EA THRESHOLD 8425 MIL NGP

1 EA CARD READER RE-USE EXISTING

* OPERATIONAL DESCRIPTION: DOORS NORMALLY CLOSED AND LOCKED. VALID CREDENTIAL POWERS OUTSIDE ACTUATOR AND ALLOWS AUTOMATIC OR MANUAL ENTRY. INSIDE ACTUATOR ALWAYS OPENS

DOOR. DOORS REMAIN LOCKED UPON LOSS OF POWER. INSIDE PUSH PADS ALWAYS FREE FOR

EGRESS.

SET 01B

1 EA CONTINUOUS HINGE 780-224HD x EPT PREP CLR HAGER

1 EA CONTINUOUS HINGE 780-224HD CLR HAGER

1 EA POWER TRANSFER EPT-10 SP28 VON DUPRIN

1 EA RIM EXIT DEVICE HD-QEL 99 NL-OP 626 VON DUPRIN

1 EA RIM EXIT DEVICE 99 EO 626 VON DUPRIN

1 EA CYLINDER AS REQUIRED 626 BEST

2 EA OFFSET PULL BF158 630 ROCKWOOD

1 EA POWER SUPPLY PS902 x 900-2RS GRY VON DUPRIN

1 EA ELECTRIC STRIKE 9600 630 HES

2 EA CLOSER 4040XP EDA 689 LCN

2 EA OVERHEAD STOP 100 SERIES 630 GJ

2 EA WEATHERSTRIP 160SA AL NGP

2 EA SWEEP 200NA AL NGP

2 EA THRESHOLD 8425 MIL NGP

1 EA CARD READER BY OTHERS

* OPERATIONAL DESCRIPTION: DOORS NORMALLY CLOSED AND LOCKED. VALID CREDENTIAL ALLOWS

ENTRY THROUGH (1) DOOR. DOORS REMAIN LOCKED UPON LOSS OF POWER. INSIDE PUSH PADS

ALWAYS FREE FOR EGRESS.

SET 02

2 EA CONTINUOUS HINGE 780-224HD x EPT PREP CLR HAGER

2 EA POWER TRANSFER EPT-10 SP28 VON DUPRIN

1 EA RIM EXIT DEVICE HD-QEL 99 NL-OP 626 VON DUPRIN

1 EA RIM EXIT DEVICE HD-QEL 99 EO 626 VON DUPRIN

1 EA CYLINDER AS REQUIRED 626 BEST

2 EA OFFSET PULL BF158 630 ROCKWOOD

1 EA POWER SUPPLY PS902 x 900-2RS GRY VON DUPRIN

1 EA AUTOMATIC OPERATOR BY OTHER SECTION

2 EA ACTUATOR BY OTHER SECTION

1 EA CLOSER 4040XP EDA 689 LCN

2 EA OVERHEAD STOP 100 SERIES 630 GJ

1 EA CARD READER BY OTHERS

* OPERATIONAL DESCRIPTION: DOORS NORMALLY CLOSED AND LOCKED. VALID CREDENTIAL POWERS

OUTSIDE ACTUATOR AND ALLOWS AUTOMATIC OR MANUAL ENTRY THROUGH (1) DOOR. INSIDE

ACTUATOR ALWAYS OPENS DOOR. DOORS REMAIN LOCKED UPON LOSS OF POWER. INSIDE PUSH

PADS ALWAYS FREE FOR EGRESS.

087100 - 13

SET 03

1 EA CONTINUOUS HINGE 780-224HD x EPT PREP CLR HAGER

1 EA POWER TRANSFER EPT-10 SP28 VON DUPRIN

1 EA RIM EXIT DEVICE HD-QEL 99 NL-OP 626 VON DUPRIN

1 EA CYLINDER AS REQUIRED 626 BEST

1 EA OFFSET PULL BF158 630 ROCKWOOD

1 EA POWER SUPPLY PS902 x 900-2RS GRY VON DUPRIN

1 EA CLOSER 4040XP EDA 689 LCN

1 EA OVERHEAD STOP 100 SERIES 630 GJ

1 EA WEATHERSTRIP 160SA AL NGP

1 EA SWEEP 200NA AL NGP

1 EA THRESHOLD 8425 MIL NGP

1 EA CARD READER RE-USE EXISTING

* OPERATIONAL DESCRIPTION: DOORS NORMALLY CLOSED AND LOCKED. VALID CREDENTIAL ALLOWS

ENTRY. DOOR REMAINS LOCKED UPON LOSS OF POWER. INSIDE PUSH PAD ALWAYS FREE FOR

EGRESS.

SET 04

2 EA CONTINUOUS HINGE 780-224HD CLR HAGER

1 EA RIM EXIT DEVICE 99 NL-OP 626 VON DUPRIN

1 EA RIM EXIT DEVICE 99 EO 626 VON DUPRIN

1 EA CYLINDER AS REQUIRED 626…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .