21-025-Golfview Heights of Westgate Water Main Replacement - Appendix C SUE Data 1.pdf
PDF 19 MB Posted
- Solicitation number
- IFB 720 WUD 21-025 2
- Issued by
- Palm Beach County, Florida
About this file
This document is Subsurface Utility Exploration (SUE) test hole data for the Golfview Heights of Westgate Water Main Replacement project in Florida, prepared for Palm Beach County Water Utilities Department (PBCWUD) Project No. WUD 21-025. The SUE data inventory documents the results of 61 test holes excavated to identify and map subsurface utilities along the project corridor. The exploration identified 38 distinct water utility lines ranging from 2 inches to 8 inches in diameter, composed primarily of cast iron, asbestos cement, ductile iron, and PVC materials. Additional utilities identified include telephone cables, buried electric conduits, and a force main. Test holes were marked with various markers including PK nails, hubs and tacks, chisels, steel pins, or spikes set over the crown or edge of discovered utilities. The survey data includes precise geographic coordinates (northing/easting), elevations, depth measurements, pipe conditions rated as good, fair, or poor, and directional orientation for each utility encountered. The project was surveyed by InfraMap on September 25, 2023, with a BFA project date of May 29, 2024, under project management by Andres Garcia (InfraMap) and Esteban Jimenez (BFA), with client coordination by Keshavarz & Associates.
The SUE data provides critical infrastructure documentation essential for planning and executing the water main replacement work while avoiding damage to existing utilities. Utility condition assessments indicate that the majority of discovered utilities are in good condition, though several water lines were documented as fair or poor condition, including 4-inch and 6-inch asbestos cement pipes. The detailed test hole notes document specific pipe configurations, including multiple water line tees ranging from 6-inch by 4-inch to 8-inch by 6-inch cast iron tees, with precise top-of-cover elevations recorded for each location. Several test holes revealed overlapping or proximate utilities, such as telephone cables running directly over water lines perpendicular to each other, requiring careful coordination during construction. Unknown utility classifications were recorded for eight test holes where pipe material or function could not be definitively determined, necessitating additional investigation or caution during excavation work.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NOTE:
LEGEND H/T
PK
X
DBC
UTILITY COMPANIES WATER
TELEPHONE
TH# TYPE OF UTILITY SIZE & MATERIAL QTY. CONDITION UTILITY
DIRECTION
SURVEY
PIN ELEV COVER TOP OF
UTIL ELEV NORTHING EASTING SHEET TEST HOLE MARKER / NOTES
1 WATER 2" CAST IRON 1 FAIR N/S 13.55 3.05 10.50 858225.6 950344.9 N/A H/T
1A UNK 2" CAST IRON 1 FAIR S 13.65 2.35 11.30 858234.5 950344.9 N/A H/T - SEE NOTES
1B WATER 4" CAST IRON 1 GOOD N/S 14.37 3.74 10.63 858440.0 950293.6 N/A H/T
2 WATER 8" ASBESTOS CEMENT 1 GOOD E/W 12.46 2.36 10.10 860108.8 951074.3 C-57 H/T 3 WATER 6"X4" CAST IRON TEE 1 GOOD E/W 12.29 2.95 9.34 858848.6 951356.7 C-65 H/T - SEE NOTES 4 TELEPHONE 1/2" DIRECT BURIED CABLE 1 GOOD NE/SW 12.33 2.48 9.85 859353.6 948804.0 C-34 H/T
5 WATER 6" ASBESTOS CEMENT 1 N/A N/S 12.24 2.35 9.89 858617.6 950559.2 C-44 PK
6 WATER 4" ASBESTOS CEMENT 1 GOOD N/S 12.86 3.22 9.64 858622.8 950347.0 C-44 PK
7 WATER 6" CAST IRON TEE 1 FAIR NW/SE 12.65 2.85 9.80 858643.2 949571.1 C-40 PK - SEE NOTES 8 WATER 6"X4" CAST IRON TEE 1 GOOD NW/SE 13.50 2.60 10.90 858928.9 949282.3 C-38 PK - SEE NOTES 9 WATER 4" ASBESTOS CEMENT 1 GOOD NE/E 13.48 3.63 9.85 859613.9 948591.7 C-34 H/T 10 WATER 6" ASBESTOS CEMENT 1 GOOD N/S 13.32 3.00 10.32 859618.7 949078.7 C-37 PK
11 TELEPHONE 4" CAST IRON 1 GOOD E/W 13.32 1.91 11.41 859617.8 949079.5 C-37 PK
12 WATER 8" ASBESTOS CEMENT 1 N/A E/W 13.33 3.45 9.88 859651.8 949133.5 C-37 PK
13 TELEPHONE 4" CAST IRON 1 GOOD N/S 13.30 2.10 11.20 859653.0 949133.8 C-37 PK
14 WATER 8" CAST IRON TEE 1 GOOD E/W 13.36 2.30 11.06 859639.6 949871.5 C-48 H/T - SEE NOTES 15 WATER 6"X4" CAST IRON TEE 1 GOOD NW/SE 12.57 2.50 10.07 859414.3 948794.1 C-34 PK - SEE NOTES 16 WATER 8"X4" CAST IRON TEE 1 GOOD E/W 13.62 3.50 10.12 859643.7 949622.8 C-42 PK - SEE NOTES 17 WATER 4" ASBESTOS CEMENT 1 GOOD N 13.61 3.15 10.46 859853.3 949642.5 C-33 H/T - SEE NOTES
TELEPHONE 1" DIRECT BURIED CABLE 1 GOOD N/S 13.52 2.50 11.02
TELEPHONE 1"-1/2" DIRECT BURIED CABLE 1 GOOD N/S 13.52 2.80 10.72
18 WATER 8"X6" CAST IRON TEE 1 GOOD N/S 13.19 2.95 10.24 859389.2 949865.1 C-48 PK - SEE NOTES
19 WATER 8" DUCTILE IRON 1 GOOD N/S 13.29 3.80 9.49 860121.8 949150.4 C-30 PK
20 BURIED ELECTRIC 2" GRAY PVC 1 GOOD E/W 13.29 3.45 9.84 860121.8 949150.4 C-30 PK 21 WATER 6" CAST IRON 1 GOOD E/W 13.50 1.85 11.65 860114.8 949647.2 C-31 H/T - SEE NOTES 22 WATER 8" ASBESTOS CEMENT 1 GOOD E/W 13.61 1.80 11.81 860162.8 949645.6 C-31 H/T 23 BURIED ELECTRIC 2" PLASTIC 1 GOOD E/W 13.61 2.45 11.16 860162.8 949645.6 C-31 H/T
24 WATER 6" PVC (BLUE) 1 GOOD N/S 13.80 3.45 10.35 859906.8 950347.3 C-50 PK
25 WATER 6" ASBESTOS CEMENT 1 GOOD E/W 12.65 3.10 9.55 859621.1 950620.5 C-55 PK
26 TELEPHONE 4" CAST IRON 1 GOOD N/S 12.65 1.57 11.08 859621.1 950620.5 C-55 PK
27 WATER 4" ASBESTOS CEMENT 1 GOOD N/S 12.42 3.20 9.22 859576.1 950870.1 C-62 PK
28 TELEPHONE 4" CAST IRON 1 GOOD E/W 12.42 1.55 10.87 859576.1 950870.1 C-62 PK
29 WATER 4" ASBESTOS CEMENT 1 GOOD N/S 12.02 2.43 9.59 859571.1 951126.1 C-64 PK
30 TELEPHONE 4" CAST IRON 1 GOOD E/W 12.02 2.02 10.00 859571.1 951126.1 C-64 PK
31 WATER 8" DIP 1 GOOD NE/SW 12.53 2.55 9.98 860117.0 951419.9 C-58 H/T
32 FORCE MAIN 4" PVC (WHITE) 1 GOOD N/S 12.65 3.42 9.23 860118.3 951420.3 C-58 H/T
33 WATER 8" DIP 1 GOOD E/W 12.67 3.50 9.17 860092.6 951507.4 C-58 H/T
34 WATER 8" ASBESTOS CEMENT 1 GOOD N/S 12.13 2.45 9.68 859819.9 951376.2 C-60 PK
35 TELEPHONE 4" CAST IRON 1 N/A E/W 12.13 1.67 10.46 859819.9 951376.2 C-60 PK
36 WATER 8" DIP TEE 1 GOOD N/S 12.20 2.08 10.12 859842.9 951430.6 C-60 PK
37 WATER 8" ASBESTOS CEMENT 1 FAIR NE/SW 12.06 5.65 6.41 859593.2 951323.1 C-66 PK
38 WATER 6" ASBESTOS CEMENT 1 GOOD E/W 12.06 2.15 9.91 859842.3 951439.8 C-60 PK
TEST HOLE INVENTORY
PROJECT: Golfview Heights of Westgate Water Main Replacement
CLIENT: KESHAVARZ & ASSOCIATES
INFRAMAP PROJECT MANAGER: ANDRES GARCIA
BFA PROJECT MANAGER: ESTEBAN JIMENEZ
PROJECT NO.: WUD 21-025
BFA DATE: 05/29/24 , INFRAMAP DATE: 09/25/2023
* SPECIFIC TEST HOLE NOTES FOLLOWING INVENTORY
INDIVIDUAL TEST HOLE MARKERS INCLUDE: PK NAIL, HUB & TACK, CHIS "X", STEEL PIN OR SPIKE.
THESE ARE SET OVER THE CROWN OR EDGE OF THE UTILITY FOUND. (SEE COLUMN LABELED TEST HOLE MARKER OR NOTES.)
HUB & TACK TEST HOLE MARKER
PK NAIL TEST HOLE MARKER
CHIS "X" TEST HOLES MARKER
DIRECT BURIED CABLE
PALM BEACH COUNTY
AT&T
17A C-33 H/T - SEE NOTES859853.3 949642.5
PBCWUD No. 21-025 Appendix "C" - SUE TH Data PAGE Appx. "C"-1
APPENDIX "C" - SUBSURFACE UTILITY EXPLORATION TEST HOLE DATA
39 UNKNOWN 6" ASBESTOS CEMENT 1 GOOD N/S 12.06 2.70 9.36 859842.3 951439.8 C-60 PK 40 UNKNOWN 4" ASBESTOS CEMENT 1 GOOD NE/SW 12.67 2.44 10.23 860073.6 951466.2 C-58 X 41 WATER 8" ASBESTOS CEMENT 1 GOOD NE/SW 12.68 3.15 9.53 860074.2 951467.3 C-58 X 42 UNKNOWN 8" ASBESTOS CEMENT 1 GOOD NE/SW 12.69 3.50 9.19 860072.4 951469.1 C-58 X 43 WATER 6" ASBESTOS CEMENT 1 GOOD E/W 13.59 2.05 11.54 860176.3 949821.6 C-31 H/T
44 WATER 8" PVC (BLUE) 1 GOOD E/W 13.58 3.17 10.41 860176.3 949821.6 C-31 H/T
46 WATER 4" ASBESTOS CEMENT 1 FAIR E/W 13.59 3.93 9.66 859864.6 949158.2 C-32 H/T
47 WATER 8" PVC (BLUE) 1 GOOD E/W 13.82 2.89 10.93 859916.1 949735.8 C-33 H/T
WATER 4" ASBESTOS CEMENT 1 POOR N/S 13.03 3.09 9.94 859625.2 948828.8
TELEPHONE 4" ASBESTOS CEMENT 1 UNK. E/W 13.03 1.48 11.55 859625.2 948828.8
49 WATER UNK. ASBESTOS CEMENT 1 POOR NW/SE 12.58 2.69 9.89 859179.5 949030.5 C-36 H/T SEE NOTE
50 WATER 6" ASBESTOS CEMENT 1 FAIR N/S 12.56 3.21 9.35 858638.8 949846.7 C-43 PK
51 WATER 4" ASBESTOS CEMENT 1 FAIR N/S 12.23 3.10 9.13 858629.6 950096.3 C-43 PK
52 WATER 4" ASBESTOS CEMENT 1 FAIR N/S 12.86 2.99 9.87 859345.3 950114.4 C-52 PK
53 WATER 6" ASBESTOS CEMENT 1 FAIR E/W 12.48 2.83 9.65 858867.7 950570.1 C-54 H/T
54 WATER 4" PVC (WHITE) 1 GOOD N/S 12.08 2.74 9.34 859315.8 950577.2 C-55 H/T
55 WATER 4" CAST IRON 1 GOOD E/W 13.09 3.02 10.07 859875.5 950621.6 C-56 PK
56 WATER 6" CAST IRON 1 FAIR N/S 13.26 2.73 10.53 860131.7 950631.2 C-56 H/T SEE NOTE
57 WATER 6" ASBESTOS CEMENT 1 FAIR E/W 12.52 3.74 8.78 859830.5 951648.5 C-60 PK
58 WATER 4" CAST IRON 1 POOR E/W 12.81 2.81 10.00 858855.0 951103.2 C-63 PK SEE NOTE
59 WATER 8" PVC (BLUE) 1 GOOD N/S 12.46 3.61 8.85 859839.5 951654.5 C-60 PK
60 WATER 8" PVC (BLUE) 1 GOOD N/S 12.40 3.47 8.93 859824.5 951654.7 C-60 PK
60A UNKNOWN 4" UNKNOWN PVC (WHITE) 1 FAIR E/W 12.47 1.60 10.87 859826.0 951653.1 C-60 PK
61 UNKNOWN 4" WRAPPED STEEL 1 FAIR N/S 12.37 3.26 9.11 859834.1 951624.9 C-60 PK
61A UNKNOWN 4" UNKNOWN PVC (WHITE) 1 FAIR E/W 12.18 2.27 9.91 859830.4 951621.2 C-60 H/T
TEST HOLE # 1A WATER
TEST HOLE # 3 WATER
TEST HOLE # 7 WATER
TEST HOLE # 8 WATER
TEST HOLE # 14 WATER
TEST HOLE # 15 WATER
TEST HOLE # 16 WATER
TEST HOLE # 17 WATER
TEST HOLE # 17A TELEPHONE
TETS HOLE # 18 WATER
TEST HOLE # 21 WATER
TEST HOLE # 48 WATER
TEST HOLE # 49 WATER
TEST HOLE # 56 WATER
TEST HOLE # 58 WATER
TEST HOLE NOTES
NOTE: ELECTRIC APPEARS TO BE 3.08' SOUTH OF HUB. UNABLE TO DIG ON DUE TO PAVING MATERIALS.
NOTE: TEE IS EAST OF PK OFFSET 1.8'. UNABLE TO GET ACCURATE SIZE DUE TO POOR PIPE CONDITION.
NOTE: 6" CIP WATER LINE 90° , T.C.=1.85
NOTE: 2" CAST IRON PIPE WITH TELEPHONE WIRES COMING OUT OF THE END T.C.= 2.35
NOTE: 6" & 4" CAST IRON PIPE TEE WATER LINE T.C.= 2.95
NOTE: 6" CIP TEE WATER LINE T.C.=2.85
NOTE: TEST HOLE ALSO REVEALED 4" AC TELEPHONE SOUTH OF PK E/W. DEPTH = 1.48', OFFSET = 1.3'
NOTE: FOUND (1) 1" DIRECT BURIED CABLE BURED TELEPHONE DEPTH=2.50 AND FOUND (1) 1.5" DIRECT BURIED CABLE BURIED TELEPHONE DEPTH=2.80. IT IS .8' +/- WEST OF THE 1" CABLE AND BOTH CABLES ARE OVER THE WATER LINE 90 DEGREES.
NOTE: 4" ASBESTOS CEMENT PIPE WATER LINE 90' T.C.=3.15
NOTE: 6" & 4" CAST IRON PIPE TEE WATER LINE T.C.= 2.60
NOTE: 8" CIP WATER LINE TEE, T.C.=2.30
NOTE: 6" & 4" CIP WATER LINE TEE, T.C.=2.50
NOTE: 8" & 4" CIP WATER LINE TEE, T.C.=3.50
NOTE: 8" & 6" CIP WATER LINE TEE, T.C.=2.95
48 PK SEE NOTE
NOTE: TEE IS WEST OF PK OFFSET 0.8'
C-35
PBCWUD No. 21-025 Appendix "C" - SUE TH Data PAGE Appx. "C"-2
PBCWUD No. 21-025 Appendix "C" - SUE TH Data
PAGE Appx. "C"-3
PAGE Appx. "C"-4
PAGE Appx. "C"-5
PAGE Appx. "C"-6
PAGE Appx. "C"-7
PAGE Appx. "C"-8
PAGE Appx. "C"-9
PAGE Appx. "C"-10
PAGE Appx. "C"-11
PAGE Appx. "C"-12
PAGE Appx. "C"-13
PAGE Appx. "C"-14
PAGE Appx. "C"-15
PAGE Appx. "C"-16
PAGE Appx. "C"-17
PAGE Appx. "C"-18
PAGE Appx. "C"-19
PAGE Appx. "C"-20
PAGE Appx. "C"-21
PAGE Appx. "C"-22
PAGE Appx. "C"-23
PAGE Appx. "C"-24
PAGE Appx. "C"-25
PAGE Appx. "C"-26
PAGE Appx. "C"-27
PAGE Appx. "C"-28
PAGE Appx. "C"-29
PAGE Appx. "C"-30
PAGE Appx. "C"-31
PAGE Appx. "C"-32
PAGE Appx. "C"-33
PAGE Appx. "C"-34
PAGE Appx. "C"-35
PAGE Appx. "C"-36
PAGE Appx. "C"-37
PAGE Appx. "C"-38
PAGE Appx. "C"-39
PAGE Appx. "C"-40
PAGE Appx. "C"-41
PAGE Appx. "C"-42
PAGE Appx. "C"-43
PAGE Appx. "C"-44
File details come from the government source that posted it. Updated .