2027-WCSU-ITB-001 Pinney Hall Roof Replace Dwgs.pdf

PDF 9 MB Posted

Attached to
Pinney Residence Hall Roof Replacement Project-Westside Campus
Solicitation number
2027-WCSU-ITB-001
Issued by
Fairfield County, Connecticut

About this file

This document is a construction drawing set prepared by ARM Architectural Services, LLC for Western Connecticut State University's Department of Administrative Services regarding the complete roof replacement of Pinney Residence Hall located on the Westside Campus in Danbury, Connecticut. The project encompasses approximately 33,248 square feet of roof area across multiple sections (Areas A through G, plus balcony and pocket roofs) and involves the complete demolition of existing roofing systems and installation of new fully adhered 0.090 EPDM membrane roofing with polyisocyanurate insulation at varying thicknesses depending on roof area. The construction documents include detailed roof plans, cross-sectional specifications for different roof areas, and comprehensive flashing and penetration details. Key work activities include removal of existing ballast (to be salvaged for the owner), membrane, and flashings; installation of new insulation, coverboard, and EPDM membrane systems; installation of new roof drains and accessories; and provision of metal flashing, scuppers, and downspouts at indicated locations. The contractor must verify all dimensions and is required to provide in-place mockups of all metal flashing and terminations for approval prior to final installation.

The construction documents dated August 6, 2026, specify numerous technical requirements including adhesive attachment patterns for insulation boards with temperature controls (65-85°F storage), mechanical fastening standards, installation of walkway pads in 30-inch widths, and detailed specifications for pipe penetrations, curb flashing, roof hatches, and edge conditions. The project requires contractor access via engineered stair tower with the roof remaining inaccessible to non-project personnel at end of each workday. Connecticut Department of Labor prevailing wage rates apply to this project, and the contract is subject to state compliance requirements including nondiscrimination statutes. The total project funding is $1,300,000 with established spending allocation goals: 1.85% ($24,111.00) for Small Business Enterprises and 0.93% ($12,056.00) for Minority Business Enterprises, with the selected contractor required to demonstrate good faith effort in meeting these goals.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WESTERN CONNECTICUT

STATE UNIVERSITY

Westside Campus

PINNEY RESIDENCE HALL

WESTERN CONNECTICUT

STATE UNIVERSITY

STATE OF CONNECTICUT

DEPARTMENT OF ADMINISTRATIVE SERVICES

DR. JESSE M. BERNAL

PRESIDENT

WESTERN CONNECTICUT STATE UNIVERSITY

MICHELLE HALLORAN GILMAN

COMMISSIONER

GOVERNOR NED LAMONT

ARCHITECTS AND ENGINEERS

ROOF REPLACEMENT

4 GRASSO DRIVE, DANBURY, CT

CONSTRUCTION DOCUMENT PHASE

AUGUST 6, 2026

ARM ARCHITECTURAL SERVICES, LLC

7 NORTHGATE DRIVE

WINDSOR LOCKS, CT 06056

8" O.C.

2" 2"

4'-0"

4' -0

4" 8"

8" 8"

8" 8"

4"

BUILDING WIND LOAD DIAGRAM

ROOF FASTENING LEGEND:

AREA 1: FIELD - N/A DUE TO BUILDING GEOMETRY

AREA 2: PERIMETER - 8" o.c. ADHESIVE PATTERN

AREA 3: CORNERS - 8" o.c. ADHESIVE PATTERN

· USE MAXIMUM 4' X 4' BOARDS

· AS ADHESIVE IS APPLIED, IMMEDIATELY PLACE INSULATION BOARD INTO WET ADHESIVE. DO NOT ALLOW

ADHESIVE TO SKIN OVER

· KEEP TEMPERATURE OFCONTENTS BETWEEN 65-85 °F 24 HOURS PRIOR TO USE.

· DO NOT STORE IN DIRECT SUNLIGHT OR TEMPERATURES 90 °F AND HIGHER

· ANY LOOSE BOARDS MUST BE MECHANICALLY SECURED

· WALK BOARDS INTO PLACE AND APPLY TEMPORARY BALLAST TO INSURE BOARDS ARE ADEQUATELY

SECURED

· DO NOT USE ADHESIVE DURING INCLEMENT WEATHER

· DO NOT APPLY ADHESIVE TO WET OR DAMP SURFACES

INSULATION ATTACHMENT w/ INSULATION ADHESIVE

33'-0"

TYP.

'-0

TY

P.

N.T.S.

G 0.02

DRAWING LIST, CODE REVIEW, AND AND

FASTENING

CAD no.

drawing prepared by project no.

project drawing no.

approved by drawn by scale date drawing title descriptiondatemark

R E V I S I O N S

WCSU - PINNEY HALL

STATE OF CONNECTICUT

DEPARTMENT OF ADMINISTRATIVE SERVICES

DANBURY, CT 06811

ROOF REPLACEMENT

professional seal

260 Bloomfield Ave, Suite 301 ARM Architectural Services, LLC

Bloomfield, CT 06095

UNIVERSITY BOULEVARD

BI-RD-329State of CT Pinney Hall

08/06/2026

JB

JCA

4"Ø

3"Ø

3"Ø

4"Ø

3"Ø

4"Ø

4"Ø

4"Ø

4"Ø

D22

D2

TYP.

D3

D1

TYP.

D5

TYP.

D6

D10

D19

D23

D17

D16

D15

PP

PP

PP

PP

M

AT

CH

L

IN

E

AA

M

AT

CH

L

IN

E

AA

PP

D8

D21

D18

D17

D20

D9

TYP.

D8 D9

D11

TYP.

TYP.

TYP.

D

E

E

F

H

H

H

H H H

HEAVY OUTLINE INDICATES

LOCATION OF HIGH PARAPET

WALLS. THESE WALLS ARE

APPROXIMATELY 8'-0" TALL AND

WILL HAVE MEMBRANE FULL

HEIGHT.

HEAVY OUTLINE INDICATES

LOCATION OF HIGH PARAPET

WALLS. THESE WALLS ARE

APPROXIMATELY 8'-0" TALL AND

WILL HAVE MEMBRANE FULL

HEIGHT.

ROOF AREA A

ROOF AREA C

ROOF AREA D

3 3

LOW

TYP.

LOW

TYP.

LOW

TYP.

D22

HIGH

TYP.

D22

HIGH

TYP.

ROOF AREA D

HIGH

TYP.

LOW

TYP.

D20

D22

TYP.

D22

TYP.

M4

TYP.

D22

TYP.

D22

TYP.

ROOF AREA

H (TYP)

WALLS ON ALL SIDES WILL

HAVE NEW MEMBRANE RUN UP

FULL HEIGHT (5'-4" +/-) PER

DETAIL DRAWINGS.

Q

TYP.

Q

TYP.

EXISTING ROOF SYSTEM

OVER CONC DECK

EXISTING PRESTRESSED HOLLOW CORE

CONCRETE PLANK DECK ACTUAL

CONFIGURATION MAY VARY.

EXISTING .045 EPDM MEMBRANE

EXISTING STONE BALLAST

EXISTING FILTER FABRIC

EXISTING 1" POLYISOCYANURATE INSULATION

EXISTING 1/4" PER FOOT TAPERED

POLYISOCYANURATE INSULATION

ROOF AREAS A & G ROOF

SYSTEM OVER CONC DECK

EXISTING PRESTRESSED HOLLOW CORE

CONCRETE PLANK DECK ACTUAL

CONFIGURATION MAY VARY.

1" POLYISOCYANURATE INSULATION SET IN

LOW-RISE FOAM

1/4" PER FOOT TAPERED POLYISOCYANURATE

INSULATION SET IN LOW-RISE FOAM

FULLY ADHERED .090 EPDM MEMBRANE

1/2" HIGH DENSITY COVERBOARD SET IN LOW-RISE

FOAM

SELF-ADHERED VAPOR BARRIER

ROOF AREA D ROOF

SYSTEM OVER CONC DECK

EXISTING PRESTRESSED HOLLOW CORE

CONCRETE PLANK DECK ACTUAL

CONFIGURATION MAY VARY.

2" POLYISOCYANURATE INSULATION SET IN

LOW-RISE FOAM

1/4" PER FOOT TAPERED POLYISOCYANURATE

INSULATION SET IN LOW-RISE FOAM

FULLY ADHERED .090 EPDM MEMBRANE

1/2" HIGH DENSITY COVERBOARD SET IN LOW-RISE

FOAM

SELF-ADHERED VAPOR BARRIER

EXISTING CROSS SECTION INFORMATION IS BASED

ON VISUAL INSPECTION. INFORMATION SHOULD BE

VERIFIED BY THE CONTRACTOR IN THE FIELD.

BALCONY ROOF AREAS ROOF

SYSTEM OVER CONC DECK

EXISTING PRESTRESSED HOLLOW CORE

CONCRETE PLANK DECK ACTUAL

CONFIGURATION MAY VARY.

(2) LAYERS OF 2" POLYISOCYANURATE

INSULATION SET IN LOW-RISE FOAM

1/4" PER FOOT TAPERED POLYISOCYANURATE

INSULATION SET IN LOW-RISE FOAM

FULLY ADHERED .090 EPDM MEMBRANE

1/2" HIGH DENSITY COVERBOARD SET IN LOW-RISE

FOAM

SELF-ADHERED VAPOR BARRIER

DRAWING NOTES:

A. CERTAIN DETAILS MAY REQUIRE FIELD ADJUSTMENT OR

MODIFICATIONS TO FIT IN A GIVEN SITUATION. AT SOME

LOCATIONS A COMBINATION OF TWO OR MORE DETAILS

ASSEMBLED TOGETHER OR RELATED SEPARATELY MAY BE

REQUIRED.

B. CLEAN, SCRAPE, WIRE BRUSH, PRIME AND PAINT, BY BRUSH,

ALL EXPOSED NON-STRUCTURAL, NON-GALVANIZED STEEL

(PLUMBING VENT PIPES ) THE COLOR AND PAINT SHALL BE AS

SPECIFIED IN THE THE SPECIFICATION.

C. CONTRACTOR ACCESS WILL BE VIA ENGINEERED STAIR TOWER.

THE ROOF SHALL BE INACCESSIBLE TO ANYONE OUTSIDE OF THE

PROJECT AT THE END OF EACH WORKDAY.

D. ROOF AREAS A & G: ROOF TO BE FULLY ADHERED .090 EPDM

OVER 1/2" HIGH DENSITY POLYISOCYANURATE INSULATION SET

IN LOW RISE FOAM OVER 1/4" PER FOOT TAPERED

POLYISOCYANURATE INSULATION SET IN LOW RISE FOAM 1"

POLYISOCYANURATE INSULATION OVER A SELF-ADHERED VAPOR

BARRIER OVER EXISTING CONCRETE DECK. ALL BOARDS TO BE SET

IN LOW RISE FOAM TO THE EXISTING STRUCTURAL DECKING.

E. ROOF AREAS B, C & F: ROOF TO BE FULLY ADHERED .090 EPDM

OVER 1/2" HIGH DENSITY POLYISOCYANURATE INSULATION SET

IN LOW RISE FOAM OVER 1/4" PER FOOT TAPERED

POLYISOCYANURATE INSULATION SET IN LOW RISE FOAM OVER 3"

POLYISOCYANURATE INSULATION OVER A SELF-ADHERED VAPOR

BARRIER OVER EXISTING CONCRETE DECK. ALL BOARDS TO BE SET

IN LOW RISE FOAM TO THE EXISTING STRUCTURAL DECKING.

F. ROOF AREA D: ROOF TO BE FULLY ADHERED .090 EPDM OVER

1/2" HIGH DENSITY POLYISOCYANURATE INSULATION SET IN LOW

RISE FOAM OVER 1/4" PER FOOT TAPERED POLYISOCYANURATE

INSULATION SET IN LOW RISE FOAM OVER 2" POLYISOCYANURATE

INSULATION OVER A SELF-ADHERED VAPOR BARRIER OVER

EXISTING CONCRETE DECK. ALL BOARDS TO BE SET IN LOW RISE

FOAM TO THE EXISTING STRUCTURAL DECKING.

G. ROOF AREA E: ROOF TO BE FULLY ADHERED .090 EPDM OVER

1/2" HIGH DENSITY POLYISOCYANURATE INSULATION SET IN LOW

RISE FOAM OVER 1/4" PER FOOT TAPERED POLYISOCYANURATE

INSULATION SET IN LOW RISE FOAM OVER A SELF-ADHERED

VAPOR BARRIER OVER EXISTING CONCRETE DECK. ALL BOARDS TO

BE SET IN LOW RISE FOAM TO THE EXISTING STRUCTURAL

DECKING.

H. BALCONY ROOF AREAS: ROOF TO BE FULLY ADHERED .090

EPDM OVER 1/2" HIGH DENSITY POLYISOCYANURATE INSULATION

SET IN LOW RISE FOAM OVER 1/4" PER FOOT TAPERED

POLYISOCYANURATE INSULATION SET IN LOW RISE FOAM OVER

(2) LAYERS OF 2" POLYISOCYANURATE INSULATION OVER A

SELF-ADHERED VAPOR BARRIER OVER EXISTING CONCRETE DECK.

ALL BOARDS TO BE SET IN LOW RISE FOAM TO THE EXISTING

STRUCTURAL DECKING.

J. INSTALL MANUFACTURER'S 30" WIDE WALKWAY PADS IN

PATTERN AS SHOWN ON PLAN.

K. PROVIDE "IN-PLACE MOCKUP" OF ALL METAL FLASHING AND

TERMINATIONS. PROVIDE AT LEAST ONE CORNER AND ONE JOINT

FOR ALL CONDITIONS FOR APPROVAL. APPROVED MOCKUPS IN

AN UNDISTURBED CONDITION AT THE TIME OF SUBSTANTIAL

COMPLETION MAY BECOME PART OF THE COMPLETED WORK.

L. UTILIZE BLIND RECEIVERS AT ALL VERTICAL TERMINATION

POINTS.

M. PROVIDE ROOF DRAINS AND ACCESSORIES PRIOR TO

INSTALLATION OF THE ROOF PER DETAIL D-1

N. PROVIDE SCUPPERS, AND DOWNSPOUTS AT INDICATED

LOCATIONS.

P. PROVIDE LIQUID FLASHING (CARLISLE OR APPROVED EQUAL)

OR 3 SIDED PITCH POCKET PER SPECIFICATION TO ENCAPSULATE

ALL CONDUIT, PIPING, OR EQUIPMENT MOUNT ALONG RISING

WALL WHERE FLASHING IS INTERRUPTED.

Q. TEMP SUPPORT THE PIPING TO ALLOW FOR ROOF TO BE

COMPLETED. PROVIDE NEW SLEEPER SUPPORTS PER THE DETAIL

DRAWINGS TO ALIGN WITH EXISTING SUPPORTS.

R. RAISE EXISTING UNITS DUE TO NEW INSULATION THICKNESS.

NEW UNITS SHOULD HAVE A MINIMUM FLASHING HEIGHT OF 8".

DEMOLITION NOTES:

1 BY HAND OR MECHANICAL MEANS, DEMOLISH AND REMOVE ANY DESIGNATED OBSOLETE

EQUIPMENT, PENETRATIONS OR DEVICES. INSTALL DECKING AND ROOFING AS DIRECTED IN THE

SPECIFICATIONS. CLIENT MECHANICAL STAFF WILL DISCONNECT POWER AND RECLAIM

REFRIGERANT OF UNITS TO BE REMOVED

2 ALL PITCH POCKETS SHALL BE DEMOLISHED TO THE DECKING. ALL CONDUITS AND OTHER

PENETRATIONS SHALL BE CLEANED AND SCRAPED PRIOR TO THE INSTALLATION OF THE PITCH

POCKET OR LIQUID FLASHINGS. DO NOT INSTALL PITCH POCKETS AROUND FLEXIBLE CONDUITS

3 REMOVE ALL BALLAST, MEMBRANE, AND FLASHINGS FROM THE ENTIRE ROOF AREA PER THE

SPECIFICATIONS. SALVAGE BALLAST FOR OWNER AND STORE AT MAINTENANCE BUILDING ON

CAMPUS

4 REMOVE ALL OF THE EXISTING DRAINS AND ASSOCIATED HARDWARE TO ALLOW FOR THE

MATERIALS PER DETAIL D-1.

5 COMPLETELY REMOVE ALL BASE FLASHINGS BEFORE REFLASHING AT ALL CURBS INCLUDING ROOF TOP UNITS. IF THE CURB IS INSULATED, REPLACE ALL DAMAGED INSULATION TO PROVIDE A SMOOTH

SUBSTRATE FOR THE BASE FLASHING.

6 DO NOT OVERLOAD STRUCTURE BY STORING DEMOLITION MATERIALS, PAVERS AND ROOFING.

DISPERSE WEIGHT ON ROOF DECK.

7 COORDINATE MOVING AND RESETTING OF LIGHTING , CAMERAS, ANY ELECTRICAL BOXES

AND CONDUIT, AND ANY OTHER EQUIPMENT ON THE ROOF OR ROOF EDGE. GIVE

OWNER/OWNER'S REPRESENTATIVE 48 HOURS NOTICE BEFORE MOVING.

KEY PLAN

ROOF AREA B, C & F ROOF

SYSTEM OVER CONC DECK

EXISTING PRESTRESSED HOLLOW CORE

CONCRETE PLANK DECK ACTUAL

CONFIGURATION MAY VARY.

3" POLYISOCYANURATE INSULATION SET IN

LOW-RISE FOAM

1/4" PER FOOT TAPERED POLYISOCYANURATE

INSULATION SET IN LOW-RISE FOAM

FULLY ADHERED .090 EPDM MEMBRANE

1/2" HIGH DENSITY COVERBOARD SET IN LOW-RISE

FOAM

SELF-ADHERED VAPOR BARRIER

3/32" - 1'-0"

RP1.01

AND NOTES

ROOF PLAN, ROOF SYSTEMS,

SYMBOL LEGEND

CU L

S

P# D#

A#

PLYWOOD/ OSB

BATT INSULATION

SEALANT/ CAULKING

STD HATCH PATTERNS:

RIGID BOARD INSULATION

HIGH DENSITY INSULATION

CONCRETE

WOOD FIBER/PERLITE

MASONRY

GYPSUM / DENS DECK

HS

PP

Picture Reference and Direction

Exp Joint or Change in Slope

Guard rail system

Asbestos sample Black = negative RED = positive

Antenna

24x24x2 Conc. paver

Condenser unit

Item to be Removed

DEMOLITION NOTE

Detail Marker

Drain w/ or w/o sump

Equipment Fan

Fall Arrest Anchor

Hot Stack

Insulation Boards

Overflow Drain

Pipe Penetration

Piping or Duct Work

Pitchpocket

Walkway pad

Smoke Hatch

Sleeper

Skylight

Scupper

Satellite Dish

RTU Curb

Roof Hatch

A DRAWING NOTE

Access Ladder

CAD no.

drawing prepared by project no.

project drawing no.

approved by drawn by scale date drawing title descriptiondatemark

R E V I S I O N S

WCSU - PINNEY HALL

STATE OF CONNECTICUT

DEPARTMENT OF ADMINISTRATIVE SERVICES

DANBURY, CT 06811

ROOF REPLACEMENT

professional seal

260 Bloomfield Ave, Suite 301 ARM Architectural Services, LLC

Bloomfield, CT 06095

UNIVERSITY BOULEVARD

BI-RD-329State of CT Pinney Hall

08/06/2026

JB

JCA

CONTRACTOR TO VERIFY

ALL DIMENSIONS

TOTAL ROOF

AREA: 33,248 SQFT ±

ROOF # APPROX SQ FT

ROOF A 16,817 SQFT ±

ROOF B 205 SQFT ±

ROOF C 187 SQFT ±

ROOF D 483 SQFT ±

ROOF E 12,899 SQFT ±

ROOF F 187 SQFT ±

ROOF G 1,403 SQFT ±

POCKET ROOFS 1,067 SQFT ±

4"Ø 4"Ø

3"Ø

3"Ø

4"Ø

4"Ø

4"Ø

ROOF AREA E

D2

TYP.

D3

D5

TYP.

D6

D1

TYP.

D16 D19 D23

D22

D15

PP

PP

PP

M

AT

C H

L

IN

E

AA

M

AT

C H

L

IN

E

AA

PP

D7

TYP.

D8 D9

TYP.

TYP.

TYP.

D

EH H H

H

H

H

G3

ROOF AREA F

3 3 3 3

M4

TYP.

ROOF AREA G

D17

LOW

TYP.

D22

HIGH

TYP.

LOW

TYP.

D22

TYP.

D23D22

TYP.

D18

LOW

TYP.

D22

TYP.

D23

TYP.ROOF AREA

H (TYP)

Q

Q

TYP.

TYP.

HEAVY OUTLINE INDICATES

LOCATION OF HIGH PARAPET

WALLS. THESE WALLS ARE

APPROXIMATELY 8'-0" TALL AND

WILL HAVE MEMBRANE FULL

HEIGHT.

EXISTING CHILLER TO REMAIN

D2

TYP.

D3

DRAWING NOTES:

A. CERTAIN DETAILS MAY REQUIRE FIELD ADJUSTMENT OR

MODIFICATIONS TO FIT IN A GIVEN SITUATION. AT SOME

LOCATIONS A COMBINATION OF TWO OR MORE DETAILS

ASSEMBLED TOGETHER OR RELATED SEPARATELY MAY BE

REQUIRED.

B. CLEAN, SCRAPE, WIRE BRUSH, PRIME AND PAINT, BY BRUSH,

ALL EXPOSED NON-STRUCTURAL, NON-GALVANIZED STEEL

(PLUMBING VENT PIPES ) THE COLOR AND PAINT SHALL BE AS

SPECIFIED IN THE THE SPECIFICATION.

C. CONTRACTOR ACCESS WILL BE VIA ENGINEERED STAIR TOWER.

THE ROOF SHALL BE INACCESSIBLE TO ANYONE OUTSIDE OF THE

PROJECT AT THE END OF EACH WORKDAY.

D. ROOF AREAS A & G: ROOF TO BE FULLY ADHERED .090 EPDM

OVER 1/2" HIGH DENSITY POLYISOCYANURATE INSULATION SET

IN LOW RISE FOAM OVER 1/4" PER FOOT TAPERED

POLYISOCYANURATE INSULATION SET IN LOW RISE FOAM 1"

POLYISOCYANURATE INSULATION OVER A SELF-ADHERED VAPOR

BARRIER OVER EXISTING CONCRETE DECK. ALL BOARDS TO BE SET

IN LOW RISE FOAM TO THE EXISTING STRUCTURAL DECKING.

E. ROOF AREAS B, C & F: ROOF TO BE FULLY ADHERED .090 EPDM

OVER 1/2" HIGH DENSITY POLYISOCYANURATE INSULATION SET

IN LOW RISE FOAM OVER 1/4" PER FOOT TAPERED

POLYISOCYANURATE INSULATION SET IN LOW RISE FOAM OVER 3"

POLYISOCYANURATE INSULATION OVER A SELF-ADHERED VAPOR

BARRIER OVER EXISTING CONCRETE DECK. ALL BOARDS TO BE SET

IN LOW RISE FOAM TO THE EXISTING STRUCTURAL DECKING.

F. ROOF AREA D: ROOF TO BE FULLY ADHERED .090 EPDM OVER

1/2" HIGH DENSITY POLYISOCYANURATE INSULATION SET IN LOW

RISE FOAM OVER 1/4" PER FOOT TAPERED POLYISOCYANURATE

INSULATION SET IN LOW RISE FOAM OVER 2" POLYISOCYANURATE

INSULATION OVER A SELF-ADHERED VAPOR BARRIER OVER

EXISTING CONCRETE DECK. ALL BOARDS TO BE SET IN LOW RISE

FOAM TO THE EXISTING STRUCTURAL DECKING.

G. ROOF AREA E: ROOF TO BE FULLY ADHERED .090 EPDM OVER

1/2" HIGH DENSITY POLYISOCYANURATE INSULATION SET IN LOW

RISE FOAM OVER 1/4" PER FOOT TAPERED POLYISOCYANURATE

INSULATION SET IN LOW RISE FOAM OVER A SELF-ADHERED

VAPOR BARRIER OVER EXISTING CONCRETE DECK. ALL BOARDS TO

BE SET IN LOW RISE FOAM TO THE EXISTING STRUCTURAL

DECKING.

H. BALCONY ROOF AREAS: ROOF TO BE FULLY ADHERED .090

EPDM OVER 1/2" HIGH DENSITY POLYISOCYANURATE INSULATION

SET IN LOW RISE FOAM OVER 1/4" PER FOOT TAPERED

POLYISOCYANURATE INSULATION SET IN LOW RISE FOAM OVER

(2) LAYERS OF 2" POLYISOCYANURATE INSULATION OVER A

SELF-ADHERED VAPOR BARRIER OVER EXISTING CONCRETE DECK.

ALL BOARDS TO BE SET IN LOW RISE FOAM TO THE EXISTING

STRUCTURAL DECKING.

J. INSTALL MANUFACTURER'S 30" WIDE WALKWAY PADS IN

PATTERN AS SHOWN ON PLAN.

K. PROVIDE "IN-PLACE MOCKUP" OF ALL METAL FLASHING AND

TERMINATIONS. PROVIDE AT LEAST ONE CORNER AND ONE JOINT

FOR ALL CONDITIONS FOR APPROVAL. APPROVED MOCKUPS IN

AN UNDISTURBED CONDITION AT THE TIME OF SUBSTANTIAL

COMPLETION MAY BECOME PART OF THE COMPLETED WORK.

L. UTILIZE BLIND RECEIVERS AT ALL VERTICAL TERMINATION

POINTS.

M. PROVIDE ROOF DRAINS AND ACCESSORIES PRIOR TO

INSTALLATION OF THE ROOF PER DETAIL D-1

N. PROVIDE SCUPPERS, AND DOWNSPOUTS AT INDICATED

LOCATIONS.

P. PROVIDE LIQUID FLASHING (CARLISLE OR APPROVED EQUAL)

OR 3 SIDED PITCH POCKET PER SPECIFICATION TO ENCAPSULATE

ALL CONDUIT, PIPING, OR EQUIPMENT MOUNT ALONG RISING

WALL WHERE FLASHING IS INTERRUPTED.

Q. TEMP SUPPORT THE PIPING TO ALLOW FOR ROOF TO BE

COMPLETED. PROVIDE NEW SLEEPER SUPPORTS PER THE DETAIL

DRAWINGS TO ALIGN WITH EXISTING SUPPORTS.

R. RAISE EXISTING UNITS DUE TO NEW INSULATION THICKNESS.

NEW UNITS SHOULD HAVE A MINIMUM FLASHING HEIGHT OF 8".

DEMOLITION NOTES:

1 BY HAND OR MECHANICAL MEANS, DEMOLISH AND REMOVE ANY DESIGNATED OBSOLETE

EQUIPMENT, PENETRATIONS OR DEVICES. INSTALL DECKING AND ROOFING AS DIRECTED IN THE

SPECIFICATIONS. CLIENT MECHANICAL STAFF WILL DISCONNECT POWER AND RECLAIM

REFRIGERANT OF UNITS TO BE REMOVED

2 ALL PITCH POCKETS SHALL BE DEMOLISHED TO THE DECKING. ALL CONDUITS AND OTHER

PENETRATIONS SHALL BE CLEANED AND SCRAPED PRIOR TO THE INSTALLATION OF THE PITCH

POCKET OR LIQUID FLASHINGS. DO NOT INSTALL PITCH POCKETS AROUND FLEXIBLE CONDUITS

3 REMOVE ALL BALLAST, MEMBRANE, AND FLASHINGS FROM THE ENTIRE ROOF AREA PER THE

SPECIFICATIONS. SALVAGE BALLAST FOR OWNER AND STORE AT MAINTENANCE BUILDING ON

CAMPUS

4 REMOVE ALL OF THE EXISTING DRAINS AND ASSOCIATED HARDWARE TO ALLOW FOR THE

MATERIALS PER DETAIL D-1.

5 COMPLETELY REMOVE ALL BASE FLASHINGS BEFORE REFLASHING AT ALL CURBS INCLUDING ROOF TOP UNITS. IF THE CURB IS INSULATED, REPLACE ALL DAMAGED INSULATION TO PROVIDE A SMOOTH

SUBSTRATE FOR THE BASE FLASHING.

6 DO NOT OVERLOAD STRUCTURE BY STORING DEMOLITION MATERIALS, PAVERS AND ROOFING.

DISPERSE WEIGHT ON ROOF DECK.

7 COORDINATE MOVING AND RESETTING OF LIGHTING , CAMERAS, ANY ELECTRICAL BOXES

AND CONDUIT, AND ANY OTHER EQUIPMENT ON THE ROOF OR ROOF EDGE. GIVE

OWNER/OWNER'S REPRESENTATIVE 48 HOURS NOTICE BEFORE MOVING.

ROOF AREAS A & G ROOF

SYSTEM OVER CONC DECK

EXISTING PRESTRESSED HOLLOW CORE

CONCRETE PLANK DECK ACTUAL

CONFIGURATION MAY VARY.

1" POLYISOCYANURATE INSULATION SET IN

LOW-RISE FOAM

1/4" PER FOOT TAPERED POLYISOCYANURATE

INSULATION SET IN LOW-RISE FOAM

FULLY ADHERED .090 EPDM MEMBRANE

1/2" HIGH DENSITY COVERBOARD SET IN LOW-RISE

FOAM

SELF-ADHERED VAPOR BARRIER

ROOF AREA B, C & F ROOF

SYSTEM OVER CONC DECK

EXISTING PRESTRESSED HOLLOW CORE

CONCRETE PLANK DECK ACTUAL

CONFIGURATION MAY VARY.

3" POLYISOCYANURATE INSULATION SET IN

LOW-RISE FOAM

1/4" PER FOOT TAPERED POLYISOCYANURATE

INSULATION SET IN LOW-RISE FOAM

FULLY ADHERED .090 EPDM MEMBRANE

1/2" HIGH DENSITY COVERBOARD SET IN LOW-RISE

FOAM

SELF-ADHERED VAPOR BARRIER

EXISTING CROSS SECTION INFORMATION IS BASED

ON VISUAL INSPECTION. INFORMATION SHOULD BE

VERIFIED BY THE CONTRACTOR IN THE FIELD.

BALCONY ROOF AREAS ROOF

SYSTEM OVER CONC DECK

EXISTING PRESTRESSED HOLLOW CORE

CONCRETE PLANK DECK ACTUAL

CONFIGURATION MAY VARY.

(2) LAYERS OF 2" POLYISOCYANURATE

INSULATION SET IN LOW-RISE FOAM

1/4" PER FOOT TAPERED POLYISOCYANURATE

INSULATION SET IN LOW-RISE FOAM

FULLY ADHERED .090 EPDM MEMBRANE

1/2" HIGH DENSITY COVERBOARD SET IN LOW-RISE

FOAM

SELF-ADHERED VAPOR BARRIER

EXISTING ROOF SYSTEM

OVER CONC DECK

EXISTING PRESTRESSED HOLLOW CORE

CONCRETE PLANK DECK ACTUAL

CONFIGURATION MAY VARY.

EXISTING .045 EPDM MEMBRANE

EXISTING STONE BALLAST

EXISTING FILTER FABRIC

EXISTING 1" POLYISOCYANURATE INSULATION

EXISTING 1/4" PER FOOT TAPERED

POLYISOCYANURATE INSULATION

ROOF AREA E ROOF

SYSTEM OVER CONC DECK

EXISTING PRESTRESSED HOLLOW CORE

CONCRETE PLANK DECK ACTUAL

CONFIGURATION MAY VARY.

1/4" PER FOOT TAPERED POLYISOCYANURATE

INSULATION SET IN LOW-RISE FOAM

FULLY ADHERED .090 EPDM MEMBRANE

1/2" HIGH DENSITY COVERBOARD SET IN LOW-RISE

FOAM

SELF-ADHERED VAPOR BARRIER

KEY PLAN

3/32" - 1'-0"

RP1.02

AND NOTES

ROOF PLAN, ROOF SYSTEMS,

SYMBOL LEGEND

CU L

S

P# D#

A#

PLYWOOD/ OSB

BATT INSULATION

SEALANT/ CAULKING

STD HATCH PATTERNS:

RIGID BOARD INSULATION

HIGH DENSITY INSULATION

CONCRETE

WOOD FIBER/PERLITE

MASONRY

GYPSUM / DENS DECK

HS

PP

Picture Reference and Direction

Exp Joint or Change in Slope

Guard rail system

Asbestos sample Black = negative RED = positive

Antenna

24x24x2 Conc. paver

Condenser unit

Item to be Removed

DEMOLITION NOTE

Detail Marker

Drain w/ or w/o sump

Equipment Fan

Fall Arrest Anchor

Hot Stack

Insulation Boards

Overflow Drain

Pipe Penetration

Piping or Duct Work

Pitchpocket

Walkway pad

Smoke Hatch

Sleeper

Skylight

Scupper

Satellite Dish

RTU Curb

Roof Hatch

A DRAWING NOTE

Access Ladder

CAD no.

drawing prepared by project no.

project drawing no.

approved by drawn by scale date drawing title descriptiondatemark

R E V I S I O N S

WCSU - PINNEY HALL

STATE OF CONNECTICUT

DEPARTMENT OF ADMINISTRATIVE SERVICES

DANBURY, CT 06811

ROOF REPLACEMENT

professional seal

260 Bloomfield Ave, Suite 301 ARM Architectural Services, LLC

Bloomfield, CT 06095

UNIVERSITY BOULEVARD

BI-RD-329State of CT Pinney Hall

08/06/2026

JB

JCA

CONTRACTOR TO VERIFY

ALL DIMENSIONS

TOTAL ROOF

AREA: 33,248 SQFT ±

ROOF # APPROX SQ FT

ROOF A 16,817 SQFT ±

ROOF B 205 SQFT ±

ROOF C 187 SQFT ±

ROOF D 483 SQFT ±

ROOF E 12,899 SQFT ±

ROOF F 187 SQFT ±

3"Ø

3"Ø

4"Ø

3"Ø

4"Ø

4"Ø

4"Ø

PP

PP

PP

PP

Q

Q

Q Q

Q

Q

Q

Q

X+2

X+2

X+

X+2

Y+

Y+2

Y+2

Y+2

X+

X+4

Q

Q

X+2 Y+2

X+4 Y+4

X+6

X+2

Y+2

X+4

Y+4

X+6

Y+6

X+8

QX+

2Y+ 2X+

Y+

4X+ 6Y+

6X+

Y+ 8X+

10Y+ 10X+

12Y+

Q X+2

Y+2

X+4 Y+4

X+6

X+2

Y+2

X+4 Y+4

X+6

Y+6

X+8

QQ

Q

X+2

X+2 Y+2

Q

X+2

Q

Y+6

X+8

Q

X+2 Y+2

X+4 Y+4

X+6

Y+6 X+8

X+2

Y+2

X+4

Y+4

X+6

Y+6

X+8

X+2

Y+2

X+4

Y+4

X+6

Y+6 X+8

Q

Q

Q

Q

X+2

X+ 2 X+2

X+2

X+2

Y+2

X+4 Y+4

X+6

Y+6

X+8

Q

X+2

Y+2

X+4

Y+4

X+6

Y+6

X+8

Q

X+2 Y+2

X+4 Y+4

X+6 Y+6

X+8

Q

Y+8 X+10

Y+10

X+2

Y+2

X+4

Y+4 X+6

X+2

Y+2

X+4

Y+4 X+6

X+2 Y+2

X+4 Y+4X+6

X+2 Y+2

X+4 Y+4

X+6 Y+6

X+8

Q

Q

Q X+

Y+

X+

Y+

X+

Y+

X+

Y+

QQQ

Q

Q

Q

Q

Q Q+2

M

AT

CH

L

IN

E

AA

M

AT

CH

L

IN

E

AA

PP

Q Q+2

Q

QQ+2

Q+2

Q+4

Q+4

Q Q+2

Q Q

Q

Q+2 Q+2

Q+2

Q+4 Q+4

Q+6

Q Q+2

Q Q+2

Q Q+2

Q

Q+2

Q

Q

Q Q+2

Q+2 Q+2

Q+2 Q+2 Q+2

Q

Q

Q Q+4

Q Q

Q

Q+2 Q+2

Q+2

Q+4 Q+4

Q+4

Q

Q Q

R

R

R

R

R

R

R R

X+2 Y+2

X+4 Y+4 X+6 Y+6

2"

2"

2"

1/2" COVERBOARD

Q

1/4" PER 1' TAPERED INSULATION

2"

4"

5"

6"

7"

8"

9"

ROOF A

X+8 Y+8 X+1 0 Y+1

0 X+1 2 Y+1

" 12

" 13 " 14

" 15

2"

2"

2"

NEW 1" BASE LAYER

NEW 3" BASE LAYER

X+2 Y+2

2"

1/2" COVERBOARD

Q

1/4" PER 1' TAPERED INSULATION

4" 6"

7"

8"

ROOFS B, C & F

1/2 " C

OVERBOARD

Q

1/2" PER 1' TAPERED INSULATION

5"

7"

POCKET ROOFS

NEW 2"

BASE LAYER

NEW 2"

BASE LAYER

NEW 2" BASE LAYER

X+2 Y+2

2"

1/2" COVERBOARD

Q

1/4" PER 1' TAPERED INSULATION

3"

5"

6"

7"

ROOF D

X+4

8"

2"

KEY PLAN

3/32" - 1'-0"

RP1.03

AND NOTES

ROOF PLAN, ROOF SYSTEMS,

SYMBOL LEGEND

CU L

S

P# D#

A#

PLYWOOD/ OSB

BATT INSULATION

SEALANT/ CAULKING

STD HATCH PATTERNS:

RIGID BOARD INSULATION

HIGH DENSITY INSULATION

CONCRETE

WOOD FIBER/PERLITE

MASONRY

GYPSUM / DENS DECK

HS

PP

Picture Reference and Direction

Exp Joint or Change in Slope

Guard rail system

Asbestos sample Black = negative RED = positive

Antenna

24x24x2 Conc. paver

Condenser unit

Item to be Removed

DEMOLITION NOTE

Detail Marker

Drain w/ or w/o sump

Equipment Fan

Fall Arrest Anchor

Hot Stack

Insulation Boards

Overflow Drain

Pipe Penetration

Piping or Duct Work

Pitchpocket

Walkway pad

Smoke Hatch

Sleeper

Skylight

Scupper

Satellite Dish

RTU Curb

Roof Hatch

A DRAWING NOTE

Access Ladder

CAD no.

drawing prepared by project no.

project drawing no.

approved by drawn by scale date drawing title descriptiondatemark

R E V I S I O N S

WCSU - PINNEY HALL

STATE OF CONNECTICUT

DEPARTMENT OF ADMINISTRATIVE SERVICES

DANBURY, CT 06811

ROOF REPLACEMENT

professional seal

260 Bloomfield Ave, Suite 301 ARM Architectural Services, LLC

Bloomfield, CT 06095

UNIVERSITY BOULEVARD

BI-RD-329State of CT Pinney Hall

08/06/2026

JB

JCA

CONTRACTOR TO VERIFY

ALL DIMENSIONS

TOTAL ROOF

AREA: 33,248 SQFT ±

ROOF # APPROX SQ FT

ROOF A 16,817 SQFT ±

ROOF B 205 SQFT ±

ROOF C 187 SQFT ±

ROOF D 483 SQFT ±

ROOF E 12,899 SQFT ±

ROOF F 187 SQFT ±

4"Ø 4"Ø

3"Ø

3"Ø

4"Ø

4"Ø

4"Ø

4"Ø

PP

PP

PP

Q

Q

Q

Q

Q

X+2

X+2 Y+2

Y+2

X+4

Q

Q

X+2

Y+2

X+4

Y+4

X+2

Y+2 X+4

Y+4 X+6

Y+6

Q

Q

X+

X+2

Y+

Y+2

X+

X+4

Y+

X+

QQ Q

X+2

X+2 Y+2

Q

X+2 X+2

X+2

X+

X+2

Y+2

X+4 Y+4

X+6

Y+6

X+8

Q

X+2 Y+2

X+4 Y+4

X+6 Y+6

X+8

Q

X+2

Y+2

X+4

Y+4

X+6

Y+6 X+8

Q

Y+8 X+10

Y+10

X+2 Y+2

X+4 Y+4

X+6Y+6X+8

Q

Q

Q X+2

Y+2

X+4

Y+4 X+6 Y+6

QX+

Y+

X+

Y+

X+

Y+

X+

Q

Q

X+2

Y+2

X+4

Y+4

X+6

X+2 Y+2

X+4 Y+4

X+6 Y+6

X+8

Q X+2

Y+2 X+4

Y+4 X+6

Y+6 X+8

Y+8 X+10

Y+10 X+12

Y+12

Q

Q

X+2

Y+2

X+4

Y+4

X+6

X+2 Y+2

X+4 Y+4

X+6 Y+6

X+8

Q

X+2

Y+2

X+4

Y+4

X+6

Y+6 X+8

Q Q

X+2

Y+2

X+4

Y+4

X+6

X+2 Y+2

X+4 Y+4

X+6 Y+6

X+8

Y+

Q Q Q

Q

Q

Q M

AT

C

H L

IN

E

AA

M

AT

C

H L

IN

E

AA

PP

Q+4 Q+4

Q+4

Q+4

Q

Q Q+2

Q Q+2

Q

Q Q

Q+2 Q+2Q+2

Q

QQ

Q+2 Q+2

Q+2

Q

Q

Q

Q Q+2

Q+2 Q+2

Q+2

Q

Q

Q

Q Q+2

Q+2 Q+2Q+2

Q

Q

Q

R

R

R

R

X+2 Y+2

X+4 Y+4 X+6 Y+6

2"

2"

2"

1/2" COVERBOARD

Q

1/4" PER 1' TAPERED INSULATION

1"

3"

4"

5"

6"

7"

8"

9"

ROOF E

X+8 Y+8 X+1 0 Y+1

0 X+1 2 Y+1

" 11

" 12 " 13

" 14

2"

2"

2"

1/2 " C

OVERBOARD

Q

1/2" PER 1' TAPERED INSULATION

5"

7"

POCKET ROOFS

NEW 2"

BASE LAYER

NEW 2"

BASE LAYER

X+2 Y+2

X+4 Y+4 X+6 Y+6

2"

2"

2"

1/2" COVERBOARD

Q

1/4" PER 1' TAPERED INSULATION

2"

4"

5"

6"

7"

8"

9"

ROOF G

NEW 1" BASE LAYER

NEW 3" BASE LAYER

X+2 Y+2

2"

1/2" COVERBOARD

Q

1/4" PER 1' TAPERED INSULATION

4" 6"

7"

8"

ROOFS B, C & F

KEY PLAN

3/32" - 1'-0"

RP1.04

AND NOTES

ROOF PLAN, ROOF SYSTEMS,

SYMBOL LEGEND

CU L

S

P# D#

A#

PLYWOOD/ OSB

BATT INSULATION

SEALANT/ CAULKING

STD HATCH PATTERNS:

RIGID BOARD INSULATION

HIGH DENSITY INSULATION

CONCRETE

WOOD FIBER/PERLITE

MASONRY

GYPSUM / DENS DECK

HS

PP

Picture Reference and Direction

Exp Joint or Change in Slope

Guard rail system

Asbestos sample Black = negative RED = positive

Antenna

24x24x2 Conc. paver

Condenser unit

Item to be Removed

DEMOLITION NOTE

Detail Marker

Drain w/ or w/o sump

Equipment Fan

Fall Arrest Anchor

Hot Stack

Insulation Boards

Overflow Drain

Pipe Penetration

Piping or Duct Work

Pitchpocket

Walkway pad

Smoke Hatch

Sleeper

Skylight

Scupper

Satellite Dish

RTU Curb

Roof Hatch

A DRAWING NOTE

Access Ladder

CAD no.

drawing prepared by project no.

project drawing no.

approved by drawn by scale date drawing title descriptiondatemark

R E V I S I O N S

WCSU - PINNEY HALL

STATE OF CONNECTICUT

DEPARTMENT OF ADMINISTRATIVE SERVICES

DANBURY, CT 06811

ROOF REPLACEMENT

professional seal

260 Bloomfield Ave, Suite 301 ARM Architectural Services, LLC

Bloomfield, CT 06095

UNIVERSITY BOULEVARD

BI-RD-329State of CT Pinney Hall

08/06/2026

JB

JCA

CONTRACTOR TO VERIFY

ALL DIMENSIONS

TOTAL ROOF

AREA: 33,248 SQFT ±

ROOF # APPROX SQ FT

ROOF A 16,817 SQFT ±

ROOF B 205 SQFT ±

ROOF C 187 SQFT ±

ROOF D 483 SQFT ±

ROOF E 12,899 SQFT ±

ROOF F 187 SQFT ±

SCALE: N.T.S.

PHOTO 1 P-1

SCALE: N.T.S.

PHOTO 2 P-2

SCALE: N.T.S

PHOTO 3 P-3

SCALE: N.T.S.

PHOTO 5 P-5

SCALE: N.T.S.

PHOTO 7 P-7

SCALE: N.T.S

PHOTO 4 P-4

SCALE: N.T.S.

PHOTO 6 P-6

AS NOTED

RP2.01

ROOF PHOTOS

CAD no.

drawing prepared by project no.

project drawing no.

approved by drawn by scale date drawing title descriptiondatemark

R E V I S I O N S

WCSU - PINNEY HALL

STATE OF CONNECTICUT

DEPARTMENT OF ADMINISTRATIVE SERVICES

DANBURY, CT 06811

ROOF REPLACEMENT

professional seal

260 Bloomfield Ave, Suite 301 ARM Architectural Services, LLC

Bloomfield, CT 06095

UNIVERSITY BOULEVARD

BI-RD-329State of CT Pinney Hall

08/06/2026

8" M

IN

PROVIDE ADDITIONAL STRIP OF

RUBBER BETWEEN THE

DRAWBAND AND

PREMANUFACTURED BOOT.

NOTES:

1. COMPLY WITH MANUFACTURER'S REQUIREMENTS FOR FIELD TERMINATION.

2. PAINT ALL PIPES CUSTOMER'S CHOICE OF STANDARD COLORS AS SHOWN IN SPEC.

3. PROVIDE PIPE EXTENSIONS AT ALL PIPES THAT ARE NOT 12" HIGH OR HIGHER ABOVE THE

FINISHED INSULATION HEIGHT.

PIPE PENETRATION

CONTINUOUS SEALANT

STAINLESS STEEL

DRAWBAND

BASE MEMBRANE

ATTACHMENT AS REQUIRED

FOR SPECIFIC SYSTEM

CONTINUOUS

SEALANT

BASE MEMBRANE ATTACHMENT AS

REQUIRED FOR SPECIFIC SYSTEM

EXISTING STRUCTURAL DECK ACTUAL

CONFIGURATION MAY VARY. SEE PROPOSED

ROOF SYSTEM DETAIL FOR MAKE UP.

PROVIDE ADDITIONAL STRIP OF

RUBBER BETWEEN THE DRAWBAND

AND PREMANUFACTURED BOOT.8"

M

IN

CONTINUOUS

SEALANT

STAINLESS STEEL DRAWBAND

PIPE PENETRATION

CONTINUOUS SEALANT

INSTALL SEALANT BETWEEN

PIPE AND PREFABRICATED

MEMBRANE FLASHING.

NOTES:

1. COMPLY WITH MANUFACTURER'S REQUIREMENTS FOR FIELD TERMINATION.

2. PAINT ALL PIPES CUSTOMER'S CHOICE OF STANDARD COLORS AS SHOWN IN SPEC.

3. PROVIDE PIPE EXTENSIONS AT ALL PIPES THAT ARE NOT 12" HIGH OR HIGHER ABOVE THE FINISHED INSULATION HEIGHT.

NOTES:

1. THE MECHANICAL UNITS SHOULD NOT BE SET

UNTIL THE ROOF MEMBRANE AND FLASHING

HAVE BEEN INSTALLED OVER THE CURB.

2. PROVIDE 1/2" APA RATED CDX PLYWOOD AT

ALL CURBS IF CONTAMINATED WITH BUILT UP

ROOFING.

INSULATION THICKNESS

VARIES

8" M

IN

. E

XT

EN

D

CU

RB

AS

R

EQ

U

IR

ED

REINFORCED MEMBRANE ATTACHMENT

STRIP WITH SEAM PLATES AND FASTENERS

.040 KYNAR FINISH ALUMINUM

COUNTERFLASHING ATTACH @12" ON

CENTER MAX; 4" HIGH (MIN)

EXISTING UNIT. ATTACH THROUGH UNIT AT

EVERY EXISTING HOLE WITH #12 GASKETED

STAINLESS STEEL SCREWS.

SS FASTENERS

WOOD CURB

BASE OF UNIT EXTENDS 1/2'' MINIMUM BEYOND

TOP OF CURB

SEALING MATERIAL - MUST BE CONTINUOUS ON

TOP OF THE CURB

1'' MINIMUM BELOW TOP OF CURB

FLASHING RECEIVER

COUNTERFLASHING

FLASHING MEMBRANE

MECHANICAL UNIT, HOOD, ETC.ALTERNATE: EXISTING STRUCTURAL DECK ACTUAL

CONFIGURATION MAY VARY. SEE

PROPOSED ROOF SYSTEM DETAIL FOR

MAKE UP.

1/2" APA RATED CDX PLYWOOD. CHAMFER

TOP EDGE 1/2".

SEALING MATERIAL

WOOD CURB

BASE OF UNIT EXTENDS 1/2'' MINIMUM BEYOND

TOP OF CURB

NOTES:

1. IF CURB INSULATION

BACKER/SUBSTRATE IS

DAMAGED DURING ROOF

REMOVAL, REPLACE

WITH MATCHING

INSULATION.

2. PROVIDE 1/2" APA

RATED CDX PLYWOOD AT

ALL CURBS.

1'' MINIMUM BELOW TOP OF CURB

SEALING MATERIAL - MUST BE CONTINUOUS ON

TOP OF THE CURB

INSULATION

COUNTERFLASHING

WOOD NAILER

FASTENERS

RAISED CURB

FLASHING MEMBRANE

OPTIONAL

TERMINATION BAR AND

COUNTER FLASHING SHOULD BE

INCLUDED AS SHOWN ABOVE

BUT IS NOT DRAWN FOR

CLAIRTY PUPOSES.

MECHANICAL UNIT, HOOD, ETC. ATTACH AS DESCRIBED ABOVE.

8" M

IN

. E

XT

EN

D

CU

RB

AS

R

EQ

U

IR

ED

EXISTING UNIT. ATTACH THROUGH UNIT

AT EVERY EXISTING HOLE WITH #12

GASKETED STAINLESS STEEL SCREWS.

EXISTING STRUCTURAL DECK

ACTUAL CONFIGURATION

MAY VARY. SEE PROPOSED

ROOF SYSTEM DETAIL FOR

MAKE UP.

1/2" APA RATED CDX PLYWOOD

CHAMFER TOP EDGE 1/2".

REINF MEMBRANE ATTACHMENT STRIP WITH SEAM

PLATES AND FASTENERS

.040 ALUMINUM COUNTERFLASHING; 4" HIGH (MIN)

STAINLESS STEEL MIN. TWO FASTENERS PER SIDE W/

TERMINATION BAR

WOOD INFILL OR INSULATED CURB

EXISTING METAL CURB

INSULATION THICKNESS

VARIES

SCALE: 3" = 1 '- 0"

ROOF DRAIN REPLACEMENTD-1

SCALE: 3" = 1 '- 0"

FIELD WRAP PENETRATIOND-2

SCALE: 3" = 1 '- 0"

PRE-MANUFACTURED BOOTD-3

INSTALL COMPATIBLE SEALANT BETWEEN

DRAIN BOWL FLANGE AND ROOF MEMBRANE

ROOF MEMBRANE OVER

SPECIFIED INSULATION

CLAMPING RING

CAST IRON DRAIN

STRAINER

HARDWARE

ROUND CUT IN MEMBRANE; EXTEND AT

LEAST 1'' PAST CLAMPING RING

HOLE IN MEMBRANE SHOULD BE

LARGER THAN DRAIN PIPE DIAMETER

CAST IRON DRAIN BOWL

CONFIGURATION VARIES.

DECK CLAMPEXISTING STRUCTURAL DECK ACTUAL

CONFIGURATION MAY VARY. SEE PROPOSED

ROOF SYSTEM DETAIL FOR MAKE UP.

NOTES:

1. REPLACE EXISTING DRAINS WITH:

a. CAST IRON STRAINER

b. CAST IRON CLAMPING RING

c. HARDWARE

d. CAST IRON BOWL AND PAN

2. MEMBRANE SEAMS SHOULD NOT INTERSECT DRAIN CLAMPING RING.

3. CLEAR ALL DRAINS 100 FEET AFTER THE PROJECT IS COMPLETED. EXISTING BOWLS TO BE REUSED TO THE GREATEST

EXTENT POSSIBLE.

4. NO HUB CONNECTIONS.

5. PROVIDE UP TO 5'-0" OF INTERIOR PLUMBING AND CONNECTION TO EXISTING PIPE.

6. PROVIDE INSULATION AROUND PIPES AND BOWLS

7. ALL PLUMBING WORK TO BE COMPLETED BY A PLUMBER LICENSED IN THE STATE WHERE THE PROJECT IS LOCATED

DRAIN SUP PAN AS REQUIRED TO

ACCESS CONNECTIONS

SCALE: 3" = 1' - 0"

FLASHING INSTALLATION THRU SHEETD-4

BASE MEMBRANE

ATTACHMENT AS

REQUIRED FOR

SPECIFIC SYSTEM

SLEEPER 2x6'S ATTACH WITH 3" SCREWS @12"oc.

.040 ALUM. CAP CONT.

PROVIDE STAINLESS STEEL

GASKETED FASTENERS.

EXISTING HVAC FRAME (TEMP

SUPPORT AS REQUIRED TO

INSTALL ROOF MEMBRANE)

NOTES:

1. PROVIDE WATER BLOCK SEALANT FULL LENGTH AND WIDTH OF BLOCKING.

2. THE WOOD BLOCKING IS SHOWN AT THE ANTICIPATED THICKNESS OF THE INSULATION

ASSEMBLY. ANY VARIATION IN INSULATION THICKNESS DUE TO CRICKETS SHIMMING

OR OTHER CONTRACTOR INSTALLED MATERIALS MUST BE ACCOMMODATED FOR AND

THE BLOCKING MUST BE ADJUSTED TO FINISH FLUSH WITH THE INSULATION AT NO

ADDED EXPENSE TO THE BUILDING OWNER. COORDINATE HEIGHTS IN THE FIELD PRIOR

TO INSTALLATION OF THE BLOCKING.

7" M

IN

4"

STAINLESS STEEL GASKETED

FASTENERS @ 12"oc.

EXISTING STRUCTURAL DECK ACTUAL CONFIGURATION MAY

VARY. SEE PROPOSED ROOF SYSTEM DETAIL FOR MAKE UP.

SCALE: 3" = 1 '- 0"

FLASHED SLEEPERD-7

CUT MEMBRANE FROM NEAREST

EDGE TO PIPE SO ADHERED

MEMBRANE CAN BE PLACED

AROUND PIPE PENETRATION

APPLY LAP SEALANT OR

CAULKING TO ALL

EXPOSED EDGES

PREVIOUS CUT IN FIELD

MEMBRANE BELOW

SHEET

MEMBRANE

SHEET

MEMBRANE

6" (15cm) WIDE

MEMBRANE

SPLICE WITH

SecurTAPE

6"(15cm) WIDE SPLICE

TAPE

60-MIL MEMBRANE

OR 20" PS CURED

FLASHING

9" WIDE P.S.

ELASTOFORM

FLASHING

3" 7.5A MIN.

cmDIMENSIONS

1" 2.5B MIN.

A

A

B

AA

A

NOTES:

1. REMOVE ALL LEAD

AND OTHER

FLASHING BEFORE

INSTALLING

PRESSURE-SENSITIVE

PIPE SEAL.

2. PIPE SEAL MUST

HAVE INTACT RIB AT

TOP EDGE,

REGARDLESS OF PIPE

DIAMETER.

3. DECK FLANGES OF

THE MOLDED PIPE

SEAL SHALL NOT BE

OVERLAPPED, CUT

OR APPLIED OVER

ANY ANGLE

CHANGE.

SCALE: 3" = 1 '- 0"

REMOVABLE CURBD-5

SCALE: 3" = 1 '- 0"

NON-REMOVABLE CURBD-6

BASE MEMBRANE ATTACHMENT AS

REQUIRED FOR SPECIFIC SYSTEM

EXISTING STRUCTURAL DECK ACTUAL

CONFIGURATION MAY VARY. SEE PROPOSED

ROOF SYSTEM DETAIL FOR MAKE UP.

INSULATION, SEE ROOF

SYSTEM

AS NOTED

RP5.01

ROOF DETAILS

CAD no.

drawing prepared by project no.

project drawing no.

approved by drawn by scale date drawing title descriptiondatemark

R E V I S I O N S

WCSU - PINNEY HALL

STATE OF CONNECTICUT

DEPARTMENT OF ADMINISTRATIVE SERVICES

DANBURY, CT 06811

ROOF REPLACEMENT

professional seal

260 Bloomfield Ave, Suite 301 ARM Architectural Services, LLC

Bloomfield, CT 06095

UNIVERSITY BOULEVARD

BI-RD-329State of CT Pinney Hall

08/06/2026

INSULATION THICKNESS

VARIES

EXISTING STRUCTURAL DECK ACTUAL

CONFIGURATION MAY VARY. SEE PROPOSED

ROOF SYSTEM DETAIL FOR MAKE UP.

SCALE: 3" = 1 '- 0"

PITCH POCKET W/ LIQUID FLASHINGD-8

ROOF HATCH METAL CAP

EXISTING STRUCTURAL DECK

ACTUAL CONFIGURATION MAY

VARY. SEE PROPOSED ROOF

SYSTEM DETAIL FOR MAKE UP.

RUBBER OR URETHANE ROD STOCK

ADHERED IN PLACE

NOTE:

1. DO NOT INSTALL SCREWS OR FASTENERS THROUGH THE SIDES OF THE UNIT.

2. THE WOOD BLOCKING IS SHOWN AT THE ANTICIPATED THICKNESS OF THE INSULATION ASSEMBLY. ANY VARIATION IN

INSULATION THICKNESS DUE TO CRICKETS SHIMMING OR OTHER CONTRACTOR INSTALLED MATERIALS MUST BE ACCOMMODATED FOR AND THE BLOCKING MUST BE ADJUSTED TO FINISH FLUSH WITH THE INSULATION AT NO ADDED EXPENSE TO THE BUILDING OWNER. COORDINATE HEIGHTS IN THE FIELD PRIOR TO INSTALLATION OF THE BLOCKING.

EXT'G BLOCKING TO REMAIN

INSULATION, SEE ROOF

SYSTEM

BASE MEMBRANE ATTACHMENT AS

REQUIRED FOR SPECIFIC SYSTEM

SCALE: N.T.S.

ROOF HATCH SAFETYD-10

SCALE: 3" = 1 '- 0"

ROOF HATCH FLASHINGD-11

SCALE: 3" = 1' - 0"

CONCRETE WALKWAY PADD-12

NOTES:

1. DO NOT INSTALL ON FIELD OF FLASHING SEAMS.

2. LEAVE 1 1/2" TO 2" BETWEEN WALKWAY PADS.

24" X 24" X 2"

CONCRETE SPLASH PAD

FULLY ADHERED 30"

WALKWAY PAD SLIP

SHEET

ROOF ASSEMBLY

AS SPECIFIED

RUBBER WALKWAY PAD

ROOF SLOPE

ENLARGED TO SHOW SURFACE TEXTURE

30"

3" EPDM SPLICE TAPE (FACTORY LAMINATED)

3" EPDM SPLICE TAPE (FACTORY LAMINATED)

3" EPDM SPLICE TAPE (FACTORY LAMINATED)

HAND RAIL SYSTEM WITH

SELF-CLOSING GATE

EXISTING ROOF HATCH TO

REMAIN.

NOTE:

1. DO NOT INSTALL SCREWS OR FASTENERS THROUGH THE SIDES OF THE UNIT.

2. THE WOOD BLOCKING IS SHOWN AT THE ANTICIPATED THICKNESS OF THE INSULATION

ASSEMBLY. ANY VARIATION IN INSULATION THICKNESS DUE TO CRICKETS SHIMMING OR

OTHER CONTRACTOR INSTALLED MATERIALS MUST BE ACCOMMODATED FOR AND THE

BLOCKING MUST BE ADJUSTED TO FINISH FLUSH WITH THE INSULATION AT NO ADDED

EXPENSE TO THE BUILDING OWNER. COORDINATE HEIGHTS IN THE FIELD PRIOR TO

INSTALLATION OF THE BLOCKING.

D11

SLOPE

20 OZ. COPPER ENCLOSURE WITH

REMOVABLE TOP - CROSSBREAK OR

SLOPE FOR DRAINAGE. SOLDER ALL

CORNERS.

INSULATE VOID AS REQUIRED

SHEET METAL OR FLEX-TUBE

COLLAR

SLOPE PIPES DOWN AND

AWAY FROM HOOD

STAINLESS STEEL

GASKETED

FASTENERS, MIN. 2

PER SIDE

REMOVABLE SHEET

METAL FLASHING

REINFORCED MEMBRANE

ATTACHMENT STRIP WITH SEAM

PLATES AND FASTENERS

WOOD NAILERS

4" MIN. CLEARANCE FROM

PIPE TO TOP OF CURB

NOTES:

1. WHERE POSSIBLE USE IS DETAIL IN LIEU OF PITCH POCKET.

2. 8" MINIMUM FLASHING HEIGHT.

3. INSULATE THE VOID SPACE WITH ROXUL OR APPROVED EQUAL.

EXISTING STRUCTURAL DECK

ACTUAL CONFIGURATION MAY

VARY. SEE PROPOSED ROOF

SYSTEM DETAIL FOR MAKE UP.

SCALE: 3" = 1 '- 0"

PIPE THRU ROOF BOXD-9

NOTES:

1. REFER TO MANUFACTURER'S WEBSITE FOR MOST CURRENT INFORMATION.

2. APPLY LAP SEALANT AS SHOWN REFER TO MANUFACTURER'S PUBLISHED LITERATURE FOR SEAM EDGE

TREATMENT.

3. USE PRIMER TO CLEAN AND PRIME EPDM MATING SURFACES PRIOR TO INSTALLATION OF PRE-TAPED

PRODUCTS.

NOTES:

1. REFER TO MANUFACTURER'S WEBSITE FOR MOST CURRENT INFORMATION.

2. APPLY LAP SEALANT AS SHOWN REFER TO MANUFACTURER'S PUBLISHED LITERATURE FOR SEAM EDGE TREATMENT.

3. USE PRIMER TO CLEAN AND PRIME EPDM MATING SURFACES PRIOR TO INSTALLATION OF PRE-TAPED PRODUCTS.

5" FLASHING

(SECOND FLASHING)

5" FLASHING

(FIRST FLASHING)

STEP #2

STEP #1

FASTENER

WITH AP SEALANT

WATER

BLOCK

EPDM MEMBRANE

CORNER FLASHING

EPDM MEMBRANE

9" FORMFLASH

(FIRST FLASHING)

STEP #3

STEP #4

3"MIN

3"MIN

9" FORMFLASH

(SECOND FLASHING)

LAP SEALANT. SEE NOTE 2

LAP SEALANT (CONT.

ALONG BASE)

9" FORMFLASH

(FIRST FLASHING)

CONTINUOUS BEAD OF LAP

SEALANT (SEE NOTE #2)

USE APPROPRIATE

BASE TIE-IN DETAIL

USE APPROPRIATE

TERMINATION DETAIL

EPDM MEMBRANE OR CURB

FLASHING

CORNER FLASHING

(CENTERED IN CORNER)

3" MIN

3" MIN

3" MIN

EPDM MEMBRANE

3" SPLICE TAPE

9" FORMFLASH

SCALE: 3" = 1' - 0"

OUTSIDE CORNER FLASHINGD-13

SCALE: 3" = 1' - 0"

INSIDE CORNER FLASHINGD-14

SEALANT (IF

REQUIRED FOR THE

SPECIFIC SYSTEM)

FLASHING

MEMBRANE

EXTEND 1''

MINIMUM INTO PAN

APPROX. 1/4''

CLEARANCE AT CORNERS 4'' MIN. FLANGE FASTNED TO THE

EXISTING DECK w/ #12 SCEWS AT

12" OC. MIN 2 PER SIDE.

WEATHERPROOF SHEET

METAL PITCH PAN.

POURABLE SEALANT

PREPARE AND PRIME

PITCH POCKET PRIOR

TO FILLING

4" M

IN

EXISTING ELECTRICAL

LINE, STEEL ANGLE, ETC.

BASE MEMBRANE

ATTACHMENT AS REQUIRED

BY SPECIFIC SYSTEM.

ROOF MEMBRANE OVER

SPECIFIED INSULATION

CARLISLE LIQUISEAL

LIQUID FLASHING

REINFORCEMENT FLEECE

NOTES:

1. FILL THE PITCH POCKETS WITH 100% POURABLE SEALANT.

2. POURABLE SEALANT MUST BE FILLED AND RE-FILLED AS REQUIRED TO PROVIDE POSITIVE SLOPE. LEVEL FILLED PITCH

POCKETS ARE NOT ACCEPTABLE.

3. WITH A WIRE BRUSH OR BY OTHER MECHANICAL MEANS CLEAN ALL LOOSE PAINT, RUST OR OTHER CONTAMINATION

FROM THE GIVEN PENETRATION PRIOR TO PRIMING AND INSTALLING POURABLE SEALER.

4. COMPLY WITH MANUFACTURER'S REQUIREMENTS FOR LEAD COLLAR WHERE REQUIRED.

5. THE WOOD BLOCKING IS SHOWN AT THE ANTICIPATED THICKNESS OF THE INSULATION ASSEMBLY. ANY VARIATION IN

INSULATION THICKNESS DUE TO CRICKETS SHIMMING OR OTHER CONTRACTOR INSTALLED MATERIALS MUST BE ACCOMMODATED FOR AND THE BLOCKING MUST BE ADJUSTED TO FINISH FLUSH WITH THE INSULATION AT NO ADDED EXPENSE TO THE BUILDING OWNER. COORDINATE HEIGHTS IN THE FIELD PRIOR TO INSTALLATION OF THE BLOCKING.

6. ALL ITEMS MUST BE SPACED A MINIMUM OF 11

4" APART PER THE MANUFACTURER.

7. PROVIDE LIQUID FLASHING AFTER POURABLE SEALER HAS COMPLETELY CURED.

AS NOTED

RP5.02

ROOF DETAILS

CAD no.

drawing prepared by project no.

project drawing no.

approved by drawn by scale date drawing title descriptiondatemark

R E V I S I O N S

WCSU - PINNEY HALL

STATE OF CONNECTICUT

DEPARTMENT OF ADMINISTRATIVE SERVICES

DANBURY, CT 06811

ROOF REPLACEMENT

professional seal

260 Bloomfield Ave, Suite 301 ARM Architectural Services, LLC

Bloomfield, CT 06095

UNIVERSITY BOULEVARD

BI-RD-329State of CT Pinney Hall

08/06/2026

SCALE: 3" = 1' - 0"

EXPANSION JOINTD-15

NOTES:

1. THE WOOD BLOCKING IS SHOWN AT THE ANTICIPATED THICKNESS OF THE INSULATION ASSEMBLY. ANY

VARIATION IN INSULATION THICKNESS DUE TO CRICKETS SHIMMING OR OTHER CONTRACTOR INSTALLED MATERIALS MUST BE ACCOMMODATED FOR AND THE BLOCKING MUST BE ADJUSTED TO FINISH FLUSH WITH THE INSULATION AT NO ADDED EXPENSE TO THE BUILDING OWNER. COORDINATE HEIGHTS IN THE

FIELD PRIOR TO INSTALLATION OF THE BLOCKING.

2. PROVIDE ISOLATION TO ENSURE THAT ANY DISSIMILAR METALS DO NOT COME IN CONTACT WITH EACH

OTHER IN THE FINAL PRODUCT TO PREVENT GALVANIC ACTION.

BASE MEMBRANE

ATTACHMENT AS

REQUIRED FOR

SPECIFIC SYSTEM

EXISTING STRUCTURAL DECK ACTUAL CONFIGURATION MAY

VARY. SEE PROPOSED ROOF SYSTEM DETAIL FOR MAKE UP.

EXISTING BATT INSULATION

BLOCKING:

1/2" APA RATED CDX PLYWOOD

EXT'G BLOCKING TO REMAIN

MANUFACTURER APPROVED

ELASTOMERIC EXPANSION JOINT

COVER

SCALE: 3" = 1' - 0"

RISING WALL ROOFS A & GD-16

NOTES:

1. PROVIDE ISOLATION TO ENSURE THAT ANY DISSIMILAR METALS DO NOT COME IN CONTACT WITH EACH

OTHER IN THE FINAL PRODUCT TO PREVENT GALVANIC ACTION.

EXISTING STRUCTURAL DECK ACTUAL CONFIGURATION MAY

VARY. SEE PROPOSED ROOF SYSTEM DETAIL FOR MAKE UP.

SCALE: 3" = 1' - 0"

RISING WALL LOW ENTRANCE CANOPY ROOFD-17

BASE MEMBRANE ATTACHMENT AS

REQUIRED FOR SPECIFIC SYSTEM

EXISTING STRUCTURAL DECK ACTUAL CONFIGURATION MAY

VARY. SEE PROPOSED ROOF SYSTEM DETAIL FOR MAKE UP.

SCALE: 3" = 1' - 0"

RISING WALL POCKET ROOFSD-18

BASE MEMBRANE ATTACHMENT AS

REQUIRED FOR SPECIFIC SYSTEM

NOTES:

1. PROVIDE ISOLATION TO ENSURE THAT ANY DISSIMILAR METALS DO NOT COME IN CONTACT WITH EACH

OTHER IN THE FINAL PRODUCT TO PREVENT GALVANIC ACTION.

NOTES:

1. PROVIDE ISOLATION TO ENSURE THAT ANY DISSIMILAR METALS DO NOT COME IN CONTACT WITH EACH

OTHER IN THE FINAL PRODUCT TO PREVENT GALVANIC ACTION.

TERMINATION BAR

FASTENED W/

APPROPRIATE

FASTENERS @ 8''oc

INSTALL COMPRESSIBLE

ELASTOMERIC SEALANT

OR TAPE

.040 ALUMINUM

DUTCH CLIP, @

16" OC

EXISTING WEEP HOLES

EXISTING THRU-WALL

FLASHING

1/2" HD INSULATION BOARD

CHAMFER TOP EDGE.

TERMINATION BAR

FASTENED W/

APPROPRIATE

FASTENERS @ 8''oc

INSTALL COMPRESSIBLE

ELASTOMERIC SEALANT

OR TAPE

.040 ALUMINUM

DUTCH CLIP, @

16" OC

EXISTING THRU-WALL

FLASHING

1/2" HD INSULATION BOARD

CHAMFER TOP EDGE.

EXISTING WINDOW

FLASHING

INSULATION, SEE ROOF

SYSTEM

INSULATION, SEE ROOF

SYSTEM

ADHERED FLASHING

MEMBRANE BONDED TO

METAL AND FIELD MEMBRANE

BASE MEMBRANE

ATTACHMENT AS REQUIRED

FOR SPECIFIC SYSTEM

ADHERED FLASHING

MEMBRANE BONDED TO

METAL AND FIELD MEMBRANE

SCALE: 3" = 1' - 0"

BALCONY SCUPPER DETAILD-19

EXISTING STRUCTURAL DECK

ACTUAL CONFIGURATION MAY

VARY. SEE PROPOSED ROOF

SYSTEM DETAIL FOR MAKE UP.

INSULATION, SEE ROOF

SYSTEM

NOTES:

1. THE WOOD BLOCKING IS SHOWN AT THE ANTICIPATED THICKNESS OF THE INSULATION ASSEMBLY. ANY VARIATION IN INSULATION THICKNESS DUE TO CRICKETS

SHIMMING OR OTHER CONTRACTOR INSTALLED MATERIALS MUST BE ACCOMMODATED FOR AND THE BLOCKING MUST BE ADJUSTED TO FINISH FLUSH WITH THE INSULATION AT NO ADDED EXPENSE TO THE BUILDING OWNER. COORDINATE HEIGHTS IN THE FIELD PRIOR TO INSTALLATION OF THE BLOCKING.

2. PROVIDE ISOLATION TO ENSURE THAT ANY DISSIMILAR METALS DO NOT COME IN CONTACT WITH EACH OTHER IN THE FINAL PRODUCT TO PREVENT GALVANIC

ACTION.

CONT. FM-APPROVED PRE-MANUFACTURED FASCIA. FASTENERS

PER THE MANUFACTURER'S REQUIREMENTS FOR THE GIVEN WIND

SPEED.

7" V

.I.

F.

BLOCKING:

1/2" APA RATED CDX PLYWOOD

2X2

2X4 CUT AT ANGLE TO SLOPE TOWARD ROOF AREA

2X6

BLOCKING:

1/2" APA RATED CDX PLYWOOD

2X4 CUT AT ANGLE TO SLOPE

TOWARD ROOF AREA

BLOCKING:

1/2" APA RATED CDX PLYWOOD

EXISTING BLOCKING TO REMAIN

.050 ALUMINUM SCUPPER

SCALE: 3" = 1' - 0"

SCUPPER ROOF BD-20

BASE MEMBRANE

ATTACHMENT AS REQUIRED

FOR SPECIFIC SYSTEM

EXISTING STRUCTURAL DECK

ACTUAL CONFIGURATION MAY

VARY. SEE PROPOSED ROOF

SYSTEM DETAIL FOR MAKE UP.

INSULATION, SEE

ROOF SYSTEM

BLOCKING:

1/2" APA RATED CDX PLYWOOD

(2) 2X6'S

BLOCKING:

(2) 2X4'S

NOTES:

1. PROVIDE CONT. LAP SEAL UNDER METAL EDGE FLANGE.

2. THE WOOD BLOCKING IS SHOWN AT THE ANTICIPATED THICKNESS OF THE INSULATION ASSEMBLY. ANY VARIATION IN

INSULATION THICKNESS DUE TO CRICKETS SHIMMING OR OTHER CONTRACTOR INSTALLED MATERIALS MUST BE ACCOMMODATED FOR AND THE BLOCKING MUST BE ADJUSTED TO FINISH FLUSH WITH THE INSULATION AT NO ADDED EXPENSE TO THE BUILDING OWNER. COORDINATE HEIGHTS IN THE FIELD PRIOR TO INSTALLATION OF THE BLOCKING.

3. PROVIDE ISOLATION TO ENSURE THAT ANY DISSIMILAR METALS DO NOT COME IN CONTACT WITH EACH OTHER IN THE FINAL

PRODUCT TO PREVENT GALVANIC ACTION.

ADHERED FLASHING MEMBRANE BONDED

TO METAL AND FIELD MEMBRANE

PROVIDE CONT. LAP SEAL

UNDER METAL EDGE FLANGE.

3" X 5" OUTLET TUBE.

FM-APPROVED PRE-MANUFACTURED FASCIA SCUPPER

SYSTEM. FASTENERS PER THE MANUFACTURER'S

REQUIREMENTS FOR THE GIVEN WIND SPEED.

CONTINUOUS

SEALANT

CONTINUOUS SEALANT

ADHERED FLASHING MEMBRANE

BONDED TO METAL AND FIELD

MEMBRANE

1/2" HD INSULATION BOARD

CHAMFER TOP EDGE.

EXISTING STRUCTURAL DECK

ACTUAL CONFIGURATION MAY

VARY. SEE PROPOSED ROOF

SYSTEM DETAIL FOR MAKE UP.

BASE MEMBRANE

ATTACHMENT AS REQUIRED

FOR SPECIFIC SYSTEM

TERMINATION BAR

FASTENED W/

APPROPRIATE

FASTENERS @ 8''oc

INSTALL COMPRESSIBLE

ELASTOMERIC SEALANT

OR TAPE

.050 ALUMINUM

DUTCH CLIP, @

16" OC

1/2" HD INSULATION BOARD

CHAMFER TOP EDGE.

EXISTING WEEP HOLES

.040 ALUMINUM

COUNTER FLASHING

CUT EXISTING

THRU-WALL FLASHING

AS NECESSARY

INSTALL CUT IN REGLET COUNTERFLASHING AS SHOWN.

CONT. 1" WIDE LEAD WEDGES SET 8" ON CENTER OR

CLOSER AS REQUIRED - ASSURE WEDGES ARE SET TO

FINISH INSET BEYOND THE FACE OF THE WALL

INSULATION, SEE ROOF

SYSTEM

EXISTING WINDOW

AS NOTED

RP5.03

ROOF DETAILS

CAD no.

drawing prepared by project no.

project drawing no.

approved by drawn by scale date drawing title descriptiondatemark

R E V I S I O N S

WCSU - PINNEY HALL

STATE OF CONNECTICUT

DEPARTMENT OF ADMINISTRATIVE SERVICES

DANBURY, CT 06811

ROOF REPLACEMENT

professional seal

260 Bloomfield Ave, Suite 301 ARM Architectural Services, LLC

Bloomfield, CT 06095

UNIVERSITY BOULEVARD

BI-RD-329State of CT Pinney Hall

08/06/2026

EDGE BLOCKING FASTER SPACINGD-24

1" 6"

6"

1'

6" 6"

1'

6"

1 1/2" 1 1/2"VARIES

FASTENERS PER THE

SPECIFICATION AND

DETAIL DRAWINGS.

NOTES:

1. PROVIDE WERE THERE ARE EXISTING GAS, ELECTRICAL OR OTHER MECHANICAL LINES. LINE SHALL BE

SUPPORTED AT 8'-0" ON CENTER MAX IF NOT ALREADY SUPPORTED AT ANOTHER INCREMENT. IF THE

EXISTING INCREMENT OF SUPPORT IS LESS THAN 8'-0" THEN THAT INCREMENT GOVERNS.

2. PROVIDE MEMBRANE COMPATIBLE "STRAP" THROUGH THE SUPPORT TO THE MEMBRANE TO PREVENT

MOVEMENT.

NOTES:

1. PROVIDE WERE THERE ARE EXISTING GAS, ELECTRICAL OR

OTHER MECHANICAL LINES. LINE SHALL BE SUPPORTED AT

8'-0" ON CENTER MAX IF NOT ALREADY SUPPORTED AT

ANOTHER INCREMENT. IF THE EXISTING INCREMENT OF

SUPPORT IS LESS THAN 8'-0" THEN THAT INCREMENT

GOVERNS.

2. PROVIDE MEMBRANE COMPATIBLE "STRAP" THROUGH

THE SUPPORT TO THE MEMBRANE TO PREVENT

MOVEMENT.

13/16" FLEX STRUT

SCALE: NTS

CRICKETSD-25

1/2" PER 1' TAPERED CRICKETS

Q Q

LENGTH: L > 18"

LE

N

GT

H

L/

NOTES:

1. CRICKETS REQUIRED ON ALL UPHILL SIDE OF UNITS GREATER THAN 18" WIDE.

2. IF ROOF SYSTEM HAS A COVERBOARD, COVERBOARD TO ALSO BE INSTALLED OVER CRICKETS

EXISTING ROOF OBSTRUCTION, HVAC

CURB, HATCH, OR OTHER OBJECT

SCALE: 3" = 1' - 0"

ADJUSTABLE PIPE SUPPORTSD-26

SCALE: 3" = 1' - 0"

LOW PROFILE PIPE SUPPORTSD-27

CONT.FM-APPROVED PRE-MANUFACTURED FASCIA.

FASTENERS PER THE MANUFACTURER'S REQUIREMENTS FOR THE

GIVEN WIND SPEED.

7" V

.I.

F.

BASE MEMBRANE

ATTACHMENT AS

REQUIRED FOR

SPECIFIC SYSTEM

BLOCKING:

1/2" APA RATED CDX PLYWOOD

2X4

SLOPED SHIM CUT FROM 2X4

2X6

BLOCKING:

1/2" APA RATED CDX PLYWOOD

2X4 CUT AT ANGLE TO SLOPE

TOWARD ROOF AREA

1/2" HD INSULATION BOARD

CHAMFER TOP EDGE.

NOTES:

1. THE WOOD BLOCKING IS SHOWN AT THE ANTICIPATED THICKNESS OF THE INSULATION ASSEMBLY. ANY VARIATION IN

INSULATION THICKNESS DUE TO CRICKETS SHIMMING OR OTHER CONTRACTOR INSTALLED MATERIALS MUST BE ACCOMMODATED FOR AND THE BLOCKING MUST BE ADJUSTED TO FINISH FLUSH WITH THE INSULATION AT NO ADDED EXPENSE TO THE BUILDING OWNER. COORDINATE HEIGHTS IN THE FIELD PRIOR TO INSTALLATION OF THE BLOCKING.

2. PROVIDE ISOLATION TO ENSURE THAT ANY DISSIMILAR METALS DO NOT COME IN CONTACT WITH EACH OTHER IN THE FINAL

PRODUCT TO PREVENT GALVANIC ACTION.

SCALE: 3" = 1' - 0"

ROOF EDGED-22

EXISTING STRUCTURAL DECK

ACTUAL CONFIGURATION MAY

VARY. SEE PROPOSED ROOF

SYSTEM DETAIL FOR MAKE UP.

INSULATION, SEE

ROOF SYSTEM

" V

.I.

F.

CONT. FM-APPROVED PRE-MANUFACTURED

FASCIA. FASTENERS PER THE MANUFACTURER'S

REQUIREMENTS FOR THE GIVEN WIND SPEED.

SCALE: 3" = 1' - 0"

ROOF B EDGED-21

BASE MEMBRANE

ATTACHMENT AS

REQUIRED FOR

SPECIFIC SYSTEM

EXISTING STRUCTURAL DECK

ACTUAL CONFIGURATION MAY

VARY. SEE PROPOSED ROOF

SYSTEM DETAIL FOR MAKE UP.

INSULATION, SEE

ROOF SYSTEM

BLOCKING:

1/2" APA RATED CDX PLYWOOD

2X4

SHIM CUT FROM 2X4

(2) 2X6'S

BLOCKING:

(2) 2X4'S

NOTES:

1. THE WOOD BLOCKING IS SHOWN AT THE ANTICIPATED THICKNESS OF THE INSULATION ASSEMBLY. ANY VARIATION IN

INSULATION THICKNESS DUE TO CRICKETS SHIMMING OR OTHER CONTRACTOR INSTALLED MATERIALS MUST BE ACCOMMODATED FOR AND THE BLOCKING MUST BE ADJUSTED TO FINISH FLUSH WITH THE INSULATION AT NO ADDED EXPENSE TO THE BUILDING OWNER. COORDINATE HEIGHTS IN THE FIELD PRIOR TO INSTALLATION OF THE BLOCKING.

2. PROVIDE ISOLATION TO ENSURE THAT ANY DISSIMILAR METALS DO NOT COME IN CONTACT WITH EACH OTHER IN THE FINAL

PRODUCT TO PREVENT GALVANIC ACTION.

CONT.FM-APPROVED PRE-MANUFACTURED FASCIA. FASTENERS PER

THE MANUFACTURER'S REQUIREMENTS FOR THE GIVEN WIND SPEED.

BASE MEMBRANE ATTACHMENT AS

REQUIRED FOR SPECIFIC SYSTEM

BLOCKING:

2X6 WITH CHAMFERED EDGE

CUT EXISTING PLYWOOD BLOCKING

FLUSH WITH BLOCKING

1/2" HD INSULATION BOARD

CHAMFER TOP EDGE.

EXISTING STRUCTURAL DECK ACTUAL

CONFIGURATION MAY VARY. SEE PROPOSED

ROOF SYSTEM DETAIL FOR MAKE UP.

INSULATION, SEE

ROOF SYSTEM

7" V

.I.

F.

SCALE: 3" = 1' - 0"

ROOF EDGED-23

NOTES:

1. THE WOOD BLOCKING IS SHOWN AT THE ANTICIPATED THICKNESS OF THE INSULATION ASSEMBLY. ANY VARIATION IN

INSULATION THICKNESS DUE TO CRICKETS SHIMMING OR OTHER CONTRACTOR INSTALLED MATERIALS MUST BE ACCOMMODATED FOR AND THE BLOCKING MUST BE ADJUSTED TO FINISH FLUSH WITH THE INSULATION AT NO ADDED EXPENSE TO THE BUILDING OWNER. COORDINATE HEIGHTS IN THE FIELD PRIOR TO INSTALLATION OF THE BLOCKING.

2. PROVIDE ISOLATION TO ENSURE THAT ANY DISSIMILAR METALS DO NOT COME IN CONTACT WITH EACH OTHER IN THE FINAL

PRODUCT TO PREVENT GALVANIC ACTION.

AS NOTED

RP5.04

ROOF DETAILS

CAD no.

drawing prepared by project no.

project drawing no.

approved by drawn by scale date drawing title descriptiondatemark

R E V I S I O N S

WCSU - PINNEY HALL

STATE OF CONNECTICUT

DEPARTMENT OF ADMINISTRATIVE SERVICES

DANBURY, CT 06811

ROOF REPLACEMENT

professional seal

260 Bloomfield Ave, Suite 301 ARM Architectural Services, LLC

Bloomfield, CT 06095

UNIVERSITY BOULEVARD

BI-RD-329State of CT Pinney Hall

08/06/2026

CONCRETE DECK PARTIAL DEPTH REPAIRD-28

1"

EXISTING CONCRETE

OUTLINE OF SPALLED

DELAMINATED (HOLLOW)

CONCRETE

OUTLINE OF SECTION REPAIRED

WITH POLYMER REPAIR MORTAR

SAWCUT 1" DEEP

REMOVE ALL LOOSE AND UNSOUND CONCRETE

REMOVE DAMAGED SURFACE

CONCRETE AND REPLACE WITH

POLYMER REPAIR MORTAR

RE

M

O

VE

A

LL

L O

O

SE

A N

D U

N

SO

U N

D

CO

N

CR

ET

E

SCALE: N.T.S.

BLIND RECEIVERD-31

BLIND RECEIVER

BLIND RECEIVER

APPROPRIATE FASTENERS 6" OR

MINIMUM TWO PER SECTION

ROOFING MATERIAL

3/8" FLAT HEM

PLAN

NOTES:

1. THE BLIND RECEIVER SHALL BE USED AT ALL MEMBRANE OR METAL, HORIZONTAL OR VERTICAL

TERMINATION AS DIRECTED.

2. THE RECEIVER SHALL BE SET IN SPECIFIED URETHANE CAULKING AND A BEAD OF CAULKING

SHALL LAID INTERNALLY PRIOR TO FINISHING THE RECEIVER CLOSED.

3. DIMENSIONS OF A GIVEN RECEIVER MAY VARY.

4. WHEN THE RECEIVER IS COMBINED WITH COPING CAP, COUNTER FLASHING OR OTHER FLASHING

DEVICES IT WILL BE MITERED, SEAMED OR OTHERWISE MECHANICALLY SECURED SO AS TO

PROVIDE

2 - 1/2" +/-

1 - 1/2"

TERMINATION BAR

APPROPRIATE FASTENER FOR

SUBSTRATE

TERMINATION BAR

SET BLIND RECEIVER IN

WATERBLOCK

ROOFING MEMBRANE

4"

1" WIDE "DUTCH"

RETENTION CLIP @16"oc

MAX.

1/2" CONTINUOUS

CLOSED HEM

FABRICATE PROFILE TO

ACCOMMODATE THE

TERMINATION BAR AND TO

MATCH THE EXISTING COUNTER

FLASHING ALREADY IN PLACE.

COMPRESSION LEG

FOR REGLET

SPECIFIED METAL

NOTE:

1. PROVIDE ISOLATION TO ENSURE THAT ANY DISSIMILAR METALS DO NOT COME IN CONTACT

WITH EACH OTHER IN THE FINAL PRODUCT TO PREVENT GALVANIC ACTION.

3/4"±

1 1/4"

SCALE: 3" = 1' - 0"

CUT-IN COUNTERFLASHINGD-30

4"

1/

2"

1" WIDE COLOR MATCHED "DUTCH"

RETENTION CLIP @16"oc MAX.

1/2" CONTINUOUS CLOSED HEM

FABRICATE PROFILE TO

ACCOMMODATE THE TERMINATION

BAR.

SPECIFIED METAL

NOTE:

1. PROVIDE ISOLATION TO ENSURE

THAT ANY DISSIMILAR METALS DO

NOT COME IN CONTACT WITH EACH

OTHER IN THE FINAL PRODUCT TO

PREVENT GALVANIC ACTION.

SCALE: 3" = 1' - 0"

COUNTERFLASHING SKIRT METALD-29

AS NOTED

RP5.05

ROOF DETAILS

CAD no.

drawing prepared by project no.

project drawing no.

approved by drawn by scale date drawing title descriptiondatemark

R E V I S I O N S

WCSU - PINNEY HALL

STATE OF CONNECTICUT

DEPARTMENT OF ADMINISTRATIVE SERVICES

DANBURY, CT 06811

ROOF REPLACEMENT

professional seal

260 Bloomfield Ave, Suite 301 ARM Architectural Services, LLC

Bloomfield, CT 06095

UNIVERSITY BOULEVARD

BI-RD-329State of CT Pinney Hall

08/06/2026

Pinney Hall-RP-0.01
RP-0.01
Pinney Hall-RP-0.02
RP-0.02
Pinney Hall-RP-1.01 (2)
RP-1.01 (2)
Pinney Hall-RP-1.02 (3)
RP-1.02 (3)
Pinney Hall-RP-1.03
RP-1.03
Pinney Hall-RP-1.04
RP-1.04
Pinney Hall-RP-2.01
RP-2.01
Pinney Hall-RP-5.01
RP-5.01
Pinney Hall-RP-5.02
RP-5.02
Pinney Hall-RP-5.03
RP-5.03
Pinney Hall-RP-5.04
RP-5.04
Pinney Hall-RP-5.05
RP-5.05

File details come from the government source that posted it. Updated .