2026 Appendix A - Water Meters - Updated.xlsx
XLSX spreadsheet 23 KB Posted
- Attached to
- Water Meter
- Solicitation number
- 2026-PZI-1701
About this file
This file is a Water Meter Calibration Schedule appendix that documents eighteen water meters requiring annual inspection, testing, and calibration services at Hanscom Air Force Base and associated facilities in Massachusetts. The spreadsheet lists detailed information for each meter including customer meter numbers, manufacturer and model information, sizes ranging from 1-inch to 8-inch, locations (Steam Plant, FamCamp, Hartwell Gate, Wood Street, various buildings, Massport tarmac area, and Lincoln School), calibration methods (on-site annually), multipliers, last test dates, and special requirements such as by-pass test ports and confined space permits. Twelve meters are located on HAFB proper, two meters are in the Massport tarmac area, two meters are at FamCamp, one meter is at the Water Treatment Facility at FamCamp, and one meter is on Wood Street in Bedford, MA.
The solicitation (2026-PZI-1701) issued by the Department of the Air Force Materiel Command Lifecycle Management Center at Hanscom Air Force Base requires a contractor to provide all labor, equipment, tools, materials, and supplies necessary to inspect, test, and calibrate these eighteen water meters. The contractor must submit field test reports for each meter within seven days of testing and must be geographically located within sixty miles of the Civil Engineering Headquarters at HAFB. All work must comply with manufacturer specifications and the Performance Work Statement. Questions regarding this solicitation were due by April 25, 2026 at 1:00 PM, with answers to be posted by April 30, 2026.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2026 Meter Calibration Bid Schedule.xlsx | XLSX spreadsheet | |
| 1701 PWS Water Meter Calibration FY26 v4.pdf | ||
| Solicitation-Redacted_Redacted.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Water
| WATER METER CALIBRATION SCHEDULE | |||||||||||||||||||||
| REIMB | BLDG | EMCS Config | EMCS Connect | CUSTOMER | METER # | MAKE/MODEL | IWIMS | SIZE | UTILITY | Quantity of Calibrations | Acutal Calibrations | LOCATION | UNIT | XPLIER | LAST TEST | CALIBRATION METHOD | CALIBRATION REQUIREMENT | Comments | Water By-Pass | Test Port | Confined Space Permit Required |
| N | 1201 | N | N | Steam Plant | 14360583 | Zenner PMTB04 | 4" | WATER | 1 | 1 | Mech Room | GAL | 100 | On-Site | Annually | Has by-pass | Yes | Yes | |||
| Y | 1409 | N | N | MASTER METER - FAMCAMP | 70122912-1 | Neptune | 9100-0092 | 6 | WATER | 1 | 3 | Cmpnd Mtr / HF | FT^3 | 100 | On-Site | Annually | No by-pass | Yes | Yes | ||
| Y | 1409 | N | N | MASTER METER - FAMCAMP | 70122912-2 | Neptune | 9100-0175 | 1 | WATER | 0 | Cmpnd Mtr / HF | FT^3 | 0 | On-Site | Annually | No by-pass | Yes | Yes | |||
| N | 1439 | N | Wired | MASTER METER - HARTWELL GATE | 11900927 | Hersey FM3 | 9100-0093 | 8 | WATER | 1 | 3 | Meter Pit | FT^3 | 100 | On-Site | Annually | Has by-pass | Yes | Yes | ||
| N | MM | N | N | MASTER METER - WOOD STREET | 11900926 | Hersey FM3 | 9100-0094 | 8 | WATER | 1 | 3 | Pit / Chestnut St | FT^3 | 100 | On-Site | Annually | Has by-pass | Yes | Yes | ||
| Y | 1065 | N | N | Water Treatment Plant - FAMCAMP | 10808795 | Hersey MVR350 | 0066-0098 | 3 | WATER | 1 | 1 | Mech Room | GAL | 0 | On-Site | Annually | No by-pass | Yes | No | ||
| N | 1106 | N | N | HQ WG | 11801329 | Hersey MVR350 | 0066-0101 | 3 | WATER | 1 | 1 | Mech Room | GAL | 10 | On-Site | Annually | Has by-pass | Yes | No | ||
| N | 1305 | N | Y | Admin Bldg 3 | 11803763 | Hersey MVR350 | 0066-0104 | 3 | WATER | 1 | 1 | Mech Room | GAL | 0 | On-Site | Annually | Has by-pass | Yes | No | ||
| N | 1604 | Y | Y | CONS/LGCA | 70224444 | Neptune | 0066-0181 | 3 | WATER | 1 | 1 | Mech Room | FT^3 | 10 | On-Site | Annually | No by-pass | Yes | No | ||
| N | 1607 | N | N | Electric Research Lab | 10808798 | Hersey MVR350 | 0066-0204 | 3 | WATER | 1 | 1 | Mech Room | GAL | 0 | On-Site | Annually | No by-pass | Yes | Yes | ||
| N | 1614 | N | N | Electronic Systems BLDG - Phase I | 11803762 | Hersey MVR350 | 0066-0105 | 3 | WATER | 1 | 1 | Mech Room | GAL | 0 | On-Site | Annually | Has by-pass | Yes | No | ||
| N | 1614 | N | N | Electronic Systems BLDG - Phase II | 11803764 | Hersey MVR350 | 0066-0145 | 3 | WATER | 1 | 1 | Loading Dock | GAL | 0 | On-Site | Annually | Has by-pass | Yes | No | ||
| N | 1994 | N | N | Child Care Center | 11801340 | Hersey MVR350 | 0066-0108 | 3 | WATER | 1 | 1 | Mech Room | GAL | 0 | On-Site | Annually | Has by-pass | Yes | No | ||
| N | 1102 | N | N | Electric Research Lab | 10808797 | Hersey MVR350 | 0066-0099 | 3 | WATER | 1 | 1 | Mech Room | GAL | 0 | On-Site | Annually | Has by-pass | Yes | No | ||
| N | 1108 | N | N | Electric Research Eng | 10808793 | Hersey MVR350 | 0066-0100 | 3 | WATER | 1 | Mech Room | GAL | 100 | On-Site | Annually | Has by-pass | Yes | No | |||
| Y | LSC | N | ? | Lincoln School | 4438-0414 | Neptune | 4 | 1 | Mech Room | GAL | On-Site | Annually | |||||||||
| Y | PIT | N | N | MASSPORT Main Meter | 31944690 | Neptune | 0066-0095 | 8 | WATER | 1 | 1 | Under Runway | FT^3 | 100 | On-Site | Annually | No by-pass | Yes | Yes | ||
| Y | PIT | N | N | MASSPORT Main Meter | 60392470 | Neptune | 0066-0172 | 2 | WATER | 1 | Under Runway | GAL | 100 | On-Site | Annually | No by-pass | Yes | Yes |
| Total | 18 | ||
| Calibration Required | |||
| Size | Frequency | ||
| 5/8" | Every 10 years | ||
| 3/4" | Every 8 years | ||
| 1" | Every 6 years | ||
| 1-1/2" | Every 4 years |
| Meters 3" and above - Annually IAW Manufacturer's Recommendations (Massport has combo meter 8"/2") |
| Master Meter (6"/1" Combo) - (Manufacturer Recommends Annual Calibration) |
| Meters 3" and below - Replacement Every 10 years IAW Manufacturer's Recommendations |
| 1102 was 1102C, 1108 was 1105B, Lincoln School is back, Master Meters calib. 1/Yr.. 6/23/16 |
As of &D
File details come from the government source that posted it. Updated .