20262029_System_Improvement_Contract_RFP_Bid_Submission.xls

XLS spreadsheet 595 KB Posted

Attached to
2026-2029 System Improvement Contract RFP
Solicitation number
2026-010
Issued by
Florida

About this file

Summary

This is a Request for Proposal (RFP) for a 2026-2029 System Improvement Contract issued by a Florida electric cooperative serving Madison, Jefferson, Taylor, and Dixie Counties. The cooperative seeks contractor services to perform construction and renovation work on its primary electrical distribution system, including installation and replacement of utility poles, secondary poles, overhead conductors, underground cables in conduit, overhead and pad-mounted transformers, and meter installations across its service territory. The scope of work encompasses both new construction and retirement of existing infrastructure, with the cooperative retaining the right to perform portions of the work in-house. Projected work spans four years (2026-2029) with substantial quantities specified for major line items, including 625 wood poles of various lengths, 50 poles of other types, 120,000 feet of 336 ACSR conductor, 15 feet of underground cable assemblies, and numerous pole-top assemblies, service equipment installations, and miscellaneous components distributed across single-phase, two-phase, and three-phase configurations.

The RFP utilizes a detailed unit-cost pricing structure based on RUS (Rural Utilities Service) Bulletin 1728F standards, with separate labor and unit price columns for installation and retirement of each assembly type. All pricing fields are currently blank, requiring bidders to complete labor rates and unit costs for each line item to establish total project pricing. The contract requires compliance with Florida Underground Facility Damage Prevention and Safety Act regulations for all underground work and adherence to RUS specifications and drawings. No incumbent information, set-asides, site visit requirements, bidder conferences, specific award dates, or funding source details are specified in the pricing document provided.

View the file

Other files

File Type Posted
TCEC_Spec_Book.pdf PDF
20262029_System_Improvement_Contract_RFP.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RUS 790 Overhead Unit Cost

Overhead Construction Units - Energized at 14.4 / 24.9 kV
The Contractor shall construct all assembly in accordance with the Specifications and Drawings found attached to this contract. The Contractor will install will at its own expense any units that are not shown on the staking sheet and temporarily constructed by him to aid in construction.
Section 1 - Pole Units
A pole unit consists of the installation of one pole, one "TCEC" identification tag as indicated on the staking sheet. It does not include the pole-top assembly unit or other parts attached to the pole. The first two digits indicate the length of the pole; the third digits shows the classification per A.S.A. (Example: 40/4 or 40-4 means a 40 ft class 4 pole).
Unit NumberDescriptionLabor Unit Price
InstallRetire
2525 Foot Long Pole$ - 0$ - 0
3030 Foot Long Pole$ - 0$ - 0
3535 Foot Long Pole$ - 0$ - 0
4040 Foot Long Pole$ - 0$ - 0
4545 Foot Long Pole$ - 0$ - 0
5050 Foot Long Pole$ - 0$ - 0
5555 Foot Long Pole$ - 0$ - 0
6060 Foot Long Pole$ - 0$ - 0
6565 Foot Long Pole$ - 0$ - 0
7070 Foot Long Pole$ - 0$ - 0
5555 Foot Steel Pole$ - 0
6060 Foot Steel Pole$ - 0
7070 Foot Steel Pole$ - 0
7575 Foot Steel Pole$ - 0
TPTop Pole$ - 0
RNPRenumber Pole$ - 0
Section 2 - Conductor Assembly Units
A conductor assembly unit consists of 1,000 feet of conductor or cable for primaries, secondary's or service and includes tie wires, sleeves for splicing, connectors, and armor rods with clips and armor wire when necessary. Tree trimming necessary for installing the services and secondary's on poles not carrying the primary line is included with the conductor assembly unit and shall be performed in accordance with the directions of the Engineer. The service shall be connected to the secondary or transformer and 2 feet of conductor or cable shall be left for connecting to the consumer's service entrance. In computing the compensation to the Bidder for conductor assembly units only the horizontal distance between conductor supports or poles staked shall be used. The conductor or cable sized and types listed are the manufacture's designation.
Unit NumberDescriptionLabor Unit Price
InstallRetire
2 ACSR#2 Aluminum Clad Steel Reinforced (Sparrow)$ - 0$ - 0
4 ACSR#4 Aluminum Clad Steel Reinforced (Swante)$ - 0$ - 0
1/0 ACSR#1/0 Aluminum Clad Steel Reinforced (Raven)$ - 0$ - 0
3/0 ACSR#3/0 Aluminum Clad Steel Reinforced (Pigeon)$ - 0$ - 0
266.8 ACSR#266.6 MCM Aluminum Clad Steel Reinforced (Waxwing)$ - 0$ - 0
336 ACSR#336 MCM Aluminum Clad Steel Reinforced (Merlin)$ - 0$ - 0
6 BHD CU#6 Bare Hard Drawn Copper$ - 0$ - 0
4 BHD CU#4 Bare Hard Drawn Copper$ - 0$ - 0
2-3 STR CU#2/3 Strand Copper$ - 0$ - 0
9-1/2D CU#9-1/2D Copper$ - 0$ - 0
4-2 AL#4/2 Duplex Aluminum Service Overhead$ - 0$ - 0
6-2 AL#6/2 Duplex Aluminum Service Overhead$ - 0$ - 0
2-3 AL#2/3 Triplex Aluminum Service Overhead$ - 0$ - 0
4-3 AL#4/3 Triplex Aluminum Service Overhead$ - 0$ - 0
1/0-3 AL#1/0-3 Triplex Aluminum Service Overhead$ - 0$ - 0
3/0-3 AL#3/0-3 Triplex Aluminum Service Overhead$ - 0$ - 0
4/0-3 AL#4/0-3 Triplex Aluminum Service Overhead$ - 0$ - 0
2-4 AL#2-4 Triplex Aluminum Service Overhead$ - 0$ - 0
1/0-4 AL#1/0-4 Triplex Aluminum Service Overhead$ - 0$ - 0
3/0-4 AL#3/0-4 Triplex Aluminum Service Overhead$ - 0$ - 0
4/0-4 AL#4/0-4 Triplex Aluminum Service Overhead$ - 0$ - 0
336.4 AL#336.6 Triplex Quadruplex Service Overhead$ - 0$ - 0
1/0 CU#1/0 Copper$ - 0$ - 0
Overhead Construction Units - Energized at 14.4 / 24.9 kV
A pole top assembly unit consists of the installation of the hardware, crossarms and their appurtenances, insulators, etc. required to support the primary and neutral conductors. It does not include the pole.
Section A - Single-Phase Primary Pole Top Assembly Units
Unit NumberDescriptionLabor Unit Price
InstallRetire
VA1.0Single Support - Miscellaneous$ - 0$ - 0
VA1.01Single Support - Miscellaneous$ - 0$ - 0
VA1.011Single Support - Miscellaneous$ - 0$ - 0
VA1.011LSingle Support - Miscellaneous$ - 0$ - 0
VA1.011PSingle Support - Miscellaneous (Post Insulators)$ - 0$ - 0
VA1.01PSingle Support - Miscellaneous (Post Insulators)$ - 0$ - 0
VA1.04NPSingle Support - Miscellaneous$ - 0$ - 0
VA1.1Single Support - Tangent$ - 0$ - 0
VA1.1PSingle Support - (Tangent) (Post Insulators)$ - 0$ - 0
VA1.11Single Support - Tangent on Crossarm$ - 0$ - 0
VA1.11PSingle Support on Crossarm (Post Insulators)$ - 0$ - 0
VA1.2Single Support - Tangent$ - 0$ - 0
VA1.2PSingle Support - (Tangent) (Post Insulators)$ - 0$ - 0
VA1.3Single Support$ - 0$ - 0
VA1.3PSingle Support (Post Insulators)$ - 0$ - 0
VA2.0Double Support - Miscellaneous$ - 0$ - 0
VA2.01Double Support - Miscellaneous$ - 0$ - 0
VA2.01PDouble Support - Miscellaneous (Post Insulators)$ - 0$ - 0
VA2.021Double Support - Miscellaneous$ - 0$ - 0
VA2.021PDouble Support - Miscellaneous (Post Insulators)$ - 0$ - 0
VA2.1Double Support - Shallow Angle$ - 0$ - 0
VA2.1PDouble Support (Post Insulators)$ - 0$ - 0
VA2.21Double Support On Crossarms$ - 0$ - 0
VA3.1Suspension Angle - Angle Shoe Neutral$ - 0$ - 0
VA3.2Suspension Angle$ - 0$ - 0
VA3.3Suspension Angle - Swinging Clevis Neutral$ - 0$ - 0
VA4.1Dead End Angle (90⁰-150⁰)$ - 0$ - 0
VA4.2Dead End Angle (20⁰-90⁰)$ - 0$ - 0
VA5.1Single Dead End$ - 0$ - 0
VA5.2Single Dead End$ - 0$ - 0
VA5.21Single Dead End on Crossarms$ - 0$ - 0
VA5.3Single Dead End - Miscellaneous$ - 0$ - 0
VA5.31Single Dead End on Crossarms$ - 0$ - 0
VA5.4Single Dead End - Miscellaneous$ - 0$ - 0
VA5.71FSingle Dead End on FG Crossarm$ - 0$ - 0
VA6.1Double Dead End (Straight)$ - 0$ - 0
VA6.2Double Dead End (Feed Through)$ - 0$ - 0
VA6.21Double Dead End On Crossarms$ - 0$ - 0
VA6.41Double Dead End on Fiberglass Crossarms$ - 0$ - 0
Section B - Two-Phase Primary Pole Top Assembly Units
Unit NumberDescriptionLabor Unit Price
InstallRetire
VB1.7NPNarrow Profile with Post Insulator$ - 0$ - 0
VB1.11Single Support on Crossarm (Tangent)$ - 0$ - 0
VB1.11PSingle Support on Crossarm (Tangent) (Post Insulators)$ - 0$ - 0
VB1.12Single Support on Crossarm (Tangent)$ - 0$ - 0
VB1.12PSingle Support on Crossarm (Tangent) (Post Insulators)$ - 0$ - 0
VB1.13Single Support on Crossarm$ - 0$ - 0
VB1.13PSingle Support on Crossarm (Post Insulators)$ - 0$ - 0
VB1.14Single Support, Neutral on Crossarm$ - 0$ - 0
VB1.14PSingle Support, Neutral on Crossarm (Post Insulators)$ - 0$ - 0
VB2.21Double Support on Crossarm (Shallow Angle)$ - 0$ - 0
VB2.21PDouble Support on Crossarms (Post Insulators)$ - 0$ - 0
VB2.22Double Support Neutral on Crossarms (Shallow Angle)$ - 0$ - 0
VB2.22PDouble Support, Neutral on Crossarms (Post Insulators)$ - 0$ - 0
VB2.9NPNarrow Profile Post Insulator with Angle$ - 0$ - 0
VB3.1Suspension Angle - Angle Shoe Neutral$ - 0$ - 0
VB4.1Dead End Angle (90⁰-150⁰)$ - 0$ - 0
VB5.1Single Dead End - Vertical$ - 0$ - 0
VB5.21Single Dead End on Crossarms$ - 0$ - 0
VB5.31Single Dead End on Crossarms$ - 0$ - 0
VB5.71FSingle Dead End on Fiberglass Crossarms$ - 0$ - 0
VB5.71FDSingle Dead End on Fiberglass Crossarms$ - 0$ - 0
VB6.21Double Dead End on Crossarms$ - 0$ - 0
VB6.41Suspension Support Double Dead End on FG Crossarm$ - 0$ - 0
Section C - Three-Phase Primary Pole Top Assembly Units
Unit NumberDescriptionLabor Unit Price
InstallRetire
VC1.7NNarrow Profile Post Insulator$ - 0$ - 0
VC1.1NPSingle Support NP Back-To-Back$ - 0$ - 0
VC1.11Single Support on Crossarm (Tangent)$ - 0$ - 0
VC1.11FSingle Support on Tangent on 8' FG Crossarm$ - 0$ - 0
VC1.11LSingle Support on Crossarm (Tangent) (Large Conductor)$ - 0$ - 0
VC1.11PSingle Support on Crossarm (Tangent) (Post Insulators)$ - 0$ - 0
VC1.11PLSingle Support on Crossarm (Tangent( (PI)(LG)$ - 0$ - 0
VC1.12Single Support on Crossarm (Tangent)$ - 0$ - 0
VC1.12LSingle Support on Crossarm (Tangent) (Large Conductor)$ - 0$ - 0
VC1.12PSingle Support on Crossarm (Tangent) (Post Insulators)$ - 0$ - 0
VC1.13Single Support on Crossarm$ - 0$ - 0
VC1.13LSingle Support on Crossarm (Large Conductors)$ - 0$ - 0
VC1.13PSingle Support on Crossarm (Post Insulators)$ - 0$ - 0
VC1.41Single Support Neutral on Crossarm$ - 0$ - 0
VC1.41FSingle Support Neutral on FG Crossarm$ - 0$ - 0
VC1.41LSingle Support Neutral on Crossarm (Large Conductor)$ - 0$ - 0
VC1.41PSingle Support, Neutral on Crossarm (Post Insulators)$ - 0$ - 0
VC1.42FSingle Support Tangent on FG Crossarm (Post Insulators)$ - 0$ - 0
VC1.42PSingle Support Tangent on FG Crossarm (Post Insulators)$ - 0$ - 0
VC2.21Double Support on Crossarm$ - 0$ - 0
VC2.21FDouble Support on FG Crossarms$ - 0$ - 0
VC2.21LDouble Support on Crossarm (Shallow Angle) (Large Conductors)$ - 0$ - 0
VC2.21PDouble Support on Crossarms (Post Insulators)$ - 0$ - 0
VC2.51Double Support Neutral on Crossarms$ - 0$ - 0
VC2.51FDouble Support Neutral on 2 FG Crossarms$ - 0$ - 0
VC2.51LDouble Support Neutral on Crossarms (Large Conductor)$ - 0$ - 0
VC2.51PDouble Support, Neutral on Crossarms (Post Insulators)$ - 0$ - 0
VC2.52Double Support on 10 Foot Crossarms$ - 0$ - 0
VC2.52FDouble Support on FG Crossarms$ - 0$ - 0
VC2.52LDouble Support on 10 Foot Crossarms (Large Conductor)$ - 0$ - 0
VC2.52PDouble Support on 10-Foot Crossarms (Post Insulators)$ - 0$ - 0
VC2.9NPSingle Support Narrow Profile Vertical Angle$ - 0$ - 0
VC3.1Suspension Angle - Angle Shoe Neutral$ - 0$ - 0
VC3.2LSuspension Angle (Large Conductor) - Angle Shoe Neutral$ - 0$ - 0
VC4.1Dead End Angle (Acute)$ - 0$ - 0
VC4.2LDead End Angle (Large Conductor)$ - 0$ - 0
VC5.1Single Dead End - Vertical - (Large Conductor) Dead End Shoe Neutral$ - 0$ - 0
VC5.2LSingle Dead End - Vertical - (Large Conductor) Dead End Shoe Neutral$ - 0$ - 0
VC5.21Single Dead End on 2 Crossarms$ - 0$ - 0
VC5.21FSingle Dead End on 2 FG Crossarms$ - 0$ - 0
VC5.31Single Dead End on 3 Crossarms$ - 0$ - 0
VC5.41FSuspension Support on 10' FG Crossarm$ - 0$ - 0
VC5.71Single Dead End on Crossarm$ - 0$ - 0
VC5.71F3PH Susp Supp Sing DE on FG Crossarm$ - 0$ - 0
VC6.21Double Dead End on 2 Crossarms$ - 0$ - 0
VC6.21FSuspension Support on Double DE on FG Crossarms$ - 0$ - 0
VC6.31Double Dead End on 3 Crossarms$ - 0$ - 0
VC6.41Double Dead End on 10 Foot Crossarms$ - 0$ - 0
VC6.51Double Dead End on 10 Foot Crossarms$ - 0$ - 0
VC6.51FSuspension Support on Double DE on 10' FG Crossarms$ - 0$ - 0
Section D - Double-Circuit Primary Pole Top Assembly Units
Unit NumberDescriptionLabor Unit Price
InstallRetire
VD1.81Single Support on Crossarms (Tangent)$ - 0$ - 0
VD1.81LSingle Support on Crossarms (Tangent) (Large Conductors)$ - 0$ - 0
VD1.81PSingle Support on Crossarms (Tangent) (Post Insulators)$ - 0$ - 0
VD1.82Single Support on Crossarms (Tangent)$ - 0$ - 0
VD1.82LSingle Support on Crossarms (Tangent) (Large Conductors)$ - 0$ - 0
VD1.82PSingle Support on Crossarms (Tangent) (Post Insulators)$ - 0$ - 0
VD1.83Single Support on Crossarms$ - 0$ - 0
VD1.83LSingle Support on Crossarms (Tangent) (Large Conductors)$ - 0$ - 0
VD1.83PSingle Support on Crossarms (Post Insulators)$ - 0$ - 0
VD1.91Double Support on Crossarms$ - 0$ - 0
VD2.91LDouble Support on Crossarms (Shallow Angle) (Large Conductors)$ - 0$ - 0
VD2.91PDouble Support on Crossarms (Post Insulators)$ - 0$ - 0
VD5.71FDouble Dead Ends on FG Crossarms$ - 0$ - 0
VD6.91Double Dead Ends on Crossarms (Feed Through)$ - 0$ - 0
Section E - Guying Assembly Units
A guy assembly unit consists of the hardware, wire guy marker. An overhead guy does not include the associated pole or down guy, each of which is listed separately.
Unit NumberDescriptionLabor Unit Price
InstallRetire
E1.018M Single OH Guy$ - 0$ - 0
E1.18M Single Down Guy$ - 0$ - 0
E12.28M Spread Down Guy / Inline Type$ - 0$ - 0
E12.312.5M Spread Down Guy / Inline Type$ - 0$ - 0
E13.28M Spread Down Guy / Offset Angle$ - 0$ - 0
E13.312.5M Spread Down Guy / Offset Angle$ - 0$ - 0
E2.0112.5M Single Down Guy$ - 0$ - 0
E2.112.5M Single OH Guy$ - 0$ - 0
E3.1Single Dow Guy Wrapped$ - 0$ - 0
E3.10Guy Marker$ - 0$ - 0
E5.1G36Guy Strain Insulator 36"$ - 0$ - 0
E5.1G54Guy Strain Insulator 54"$ - 0$ - 0
E5.1G78Guy Strain Insulator 78"$ - 0$ - 0
Section F - Anchor Assembly Units
An anchor assembly units consists of the installation of an anchor with rod complete and ready for attaching to the guy wire.
Unit NumberDescriptionLabor Unit Price
InstallRetire
F2.8Anchor Screw 8" (Power Installed)$ - 0$ - 0
F2.10Anchor Screw 10" (Power Installed)$ - 0$ - 0
F2.15Anchor Screw 15" (Power Installed)$ - 0$ - 0
F7.2Double Helix Anchor$ - 0$ - 0
F7.3Triple Helix Anchor$ - 0$ - 0
Anchor Ext.Anchor Extension$ - 0$ - 0
Section G - Transformer Assembly Units
A transformer assembly unit consists of the installation of the transformer, its protective equipment and its hardware and leads with their connectors and supporting insulators and pints. This unit does not include the installation of the pole top, secondary, service or grounding assemblies.
Unit NumberDescriptionLabor Unit Price
InstallRetire
VG1.2/VG1.3 - 33 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.2/VG1.3 - 55 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.2/VG1.3 - 77 1/2 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.2/VG1.3 - 1010 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.2/VG1.3 - 1515 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.2/VG1.3 - 2525 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.2/VG1.3 - 3737 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.2/VG1.3 - 5050 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.2/VG1.3 - 7575 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.2/VG1.3 - 100100 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.2/VG1.3 - 167167 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.4/VG1.5 - 33 KVA 1Ø Transformer (Tangent)$ - 0$ - 0
VG1.4/VG1.5 - 55 KVA 1Ø Transformer (Tangent)$ - 0$ - 0
VG1.4/VG1.5 - 77 1/2 KVA 1Ø Transformer (Tangent)$ - 0$ - 0
VG1.4/VG1.5 - 1010 KVA 1Ø Transformer (Tangent)$ - 0$ - 0
VG1.4/VG1.5 - 1515 KVA 1Ø Transformer (Tangent)$ - 0$ - 0
VG1.4/VG1.5 - 2525 KVA 1Ø Transformer (Tangent)$ - 0$ - 0
VG1.4/VG1.5 - 3737 1/2 KVA 1Ø Transformer (Tangent)$ - 0$ - 0
VG1.4/VG1.5 - 5050 KVA 1Ø Transformer (Tangent)$ - 0$ - 0
VG1.4/VG1.5 - 7575 KVA 1Ø Transformer (Tangent)$ - 0$ - 0
VG1.4/VG1.5 - 100100 KVA 1Ø Transformer (Tangent)$ - 0$ - 0
VG1.4/VG1.5 - 167167 KVA 1Ø Transformer (Tangent)$ - 0$ - 0
VG1.6 - 33 KVA 1Ø Transformer (Deadend)$ - 0$ - 0
VG1.6 - 55 KVA 1Ø Transformer (Deadend)$ - 0$ - 0
VG1.6 - 77 1/2 KVA 1Ø Transformer (Deadend)$ - 0$ - 0
VG1.6 - 1010 KVA 1Ø Transformer (Deadend)$ - 0$ - 0
VG1.6 - 1515 KVA 1Ø Transformer (Deadend)$ - 0$ - 0
VG1.6 - 2525 KVA 1Ø Transformer (Deadend)$ - 0$ - 0
VG1.6 - 3737 1/2 KVA 1Ø Transformer (Deadend)$ - 0$ - 0
VG1.6 - 5050 KVA 1Ø Transformer (Deadend)$ - 0$ - 0
VG1.6 - 7575 KVA 1Ø Transformer (Deadend)$ - 0$ - 0
VG1.6 - 100100 KVA 1Ø Transformer (Deadend)$ - 0$ - 0
VG1.6 - 167167 KVA 1Ø Transformer (Deadend)$ - 0$ - 0
VG2.12Ø Trans Open Wye Open Delta 4W SE$ - 0$ - 0
VG3.13Ø Trans Bank UG Wye Pri 4W Sec$ - 0$ - 0
VG3.23Ø Trans Bank UG Wye Pri 3W Sec$ - 0$ - 0
VG3.33Ø Trans Bank Grounded Wye Prim Grounded Wye, 4W Sec$ - 0$ - 0
Section H - Grounding Assembly Units
A grounding assembly unit consists of the installation of a ground wire on the pole, installation of any required hardware, driving a ground rod or ground rods in undisturbed earth and making all of the appropriate connections.
Unit NumberDescriptionLabor Unit Price
InstallRetire
H1.2Pole Ground Assembly - Butt Type (Coil Ground Only)$ - 0
H1.11Ground Rod Assembly Only (from Existing Pole Bond)$ - 0
H1.12Ground Rod and Butt Coil / Pole Protection Assembly$ - 0
H1.ExtAdding (1) Ground Rod$ - 0
Section J - Secondary Assembly Units
A secondary assembly unit consists of the installation of the hardware, insulators, etc., to support the secondary conductor or cable. It does not include the installation of the secondary conductor or cable or any of the hardware, insulators, etc., required to support service conductors or cable.
Unit NumberDescriptionLabor Unit Price
InstallRetire
J1.1Secondary Assembly$ - 0$ - 0
J1.2Secondary Assembly - Double Upset Bolt -Small Angle$ - 0$ - 0
J2.1Secondary Assembly - Large Conductor$ - 0$ - 0
J2.10Small Angle - Secondary Assembly$ - 0$ - 0
J2.2Secondary Assembly - Service$ - 0$ - 0
J3.1Secondary Assembly - Neutral Dead End Assembly$ - 0$ - 0
Section K - Service Assembly Units
A service assembly unit consists of the installation of the hardware, insulators, etc. to support the service conductors or cable. It does not include the installation of the service conductor or cable, or any of the hardware, insulators, etc., required to support secondary conductors or cable.
Unit NumberDescriptionLabor Unit Price
InstallRetire
K1.1Service Assembly - Station Clevis (Pole Mounted)$ - 0$ - 0
K1.3Service Assembly - Swinging Clevis (Pole Mounted)$ - 0$ - 0
K1.4Service Assembly - Swinging Clevis (Pole Mounted)$ - 0$ - 0
K2.1Service Assembly -House Knob$ - 0$ - 0
K3.1Service Assembly - Common 2" Mast$ - 0$ - 0
K3.2Service Assembly - Large Mast Type$ - 0$ - 0
Section M - Miscellaneous Assembly Units
A miscellaneous assembly unit consists of the installation of an additional unit needed in the Project for the new line construction but not otherwise listed in the Proposal.
Unit NumberDescriptionLabor Unit Price
InstallRetire
JAJumper for Aluminum Conductor$ - 0$ - 0
JCJumper for CU Conductor$ - 0$ - 0
E4.PBPush Brace Pole$ - 0$ - 0
K6.2Wedge Clamp$ - 0$ - 0
VL1.2Primary Dead-End Assembly$ - 0$ - 0
L2.1Neutral Angle Assembly$ - 0$ - 0
L2.2Neutral Dead-End (Shoe) Assembly$ - 0$ - 0
L2.3Neutral Dead-End (Perform) Assembly$ - 0$ - 0
L3.3Neutral and Secondary Dead-End Clamp Assembly$ - 0$ - 0
M40.2#2 ACSR Armor Rod$ - 0$ - 0
M40.4#4 ACSR Armor Rod$ - 0$ - 0
M40.1/0#1/0 ACSR Armor Rod$ - 0$ - 0
M40.3/0#3/0 ACSR Armor Rod$ - 0$ - 0
M40.266#266 ACSR Armor Rod$ - 0$ - 0
M40.336#336 ACSR Armor Rod$ - 0$ - 0
VP1.01Lightning Arrestor (18 kV Crossarm Mount)$ - 0$ - 0
P1.01Lightning Arrestor 9KV (Crossarm)$ - 0$ - 0
P1.11Ø Lightning Arrestor Station 9 kV$ - 0$ - 0
P1.33Ø Lightning Arrestor Station 9 kV$ - 0$ - 0
VP1.33Ø Lightning Arrestor Station 18 kV$ - 0$ - 0
VR1.11Ø Oil Circuit Recloser$ - 0$ - 0
VY1.1Pole Mount Voltage Regulator$ - 0$ - 0
VY1.12Pole Mount Voltage Regulator (7200)$ - 0$ - 0
VY1.33Ø Regulator Platform$ - 0$ - 0
VY3.33Ø Regulator$ - 0$ - 0
W2.88' Wood Crossarm$ - 0$ - 0
W2.8FD8' Fiberglass Crossarm (Dead-End)$ - 0$ - 0
W2.8FT8' Fiberglass Crossarm (Tangent)$ - 0$ - 0
W2.8S8' Steel Crossarm$ - 0$ - 0
W2.1010' Wood Crossarm$ - 0$ - 0
W2.10FD10' Fiberglass Crossarm (Dead-End)$ - 0$ - 0
W2.10FT10' Fiberglass Crossarm (Tangent)$ - 0$ - 0
W3.128" Wood Crossarm Braces$ - 0$ - 0
W3.260" Wood Crossarm Braces$ - 0$ - 0
Blade Switches$ - 0$ - 0
Bog Shoe$ - 0
Bond Guy$ - 0
Bond Neutral$ - 0
Cant Pole$ - 0
Check and Replace FuseVerify proper fuse size to OCR size and replace fuse as required.$ - 0
Dead End Shoe$ - 0$ - 0
Fuse Number$ - 0$ - 0
Hardware ClothInstall hardware cloth for woodpecker protection$ - 0
Jumper$ - 0$ - 0
Lower Guy$ - 0
Lower Neutral$ - 0
Lower Phone$ - 0
Lower Service$ - 0
Mini-Max$ - 0$ - 0
Plumb Pole$ - 0
Rebond Pole Bond$ - 0
Rebond Transformer$ - 0
Relocate Transformer$ - 0
Remove VinesCut vines from the pole and guy. (Cut at ground level)$ - 0
Repair Pole Ground$ - 0
Repull GuyLoosen guy clamp or perform and tighten the guy$ - 0
Resag NeutralUntie and resag neutral conductor to phase conductor$ - 0
Resag Primary$ - 0
Resag 3-Wire Secondary$ - 0
Resag ServiceLoosen triplex cable dead end and resag$ - 0
Restaple Pole$ - 0
Retire Cable TV/T-phoneSame as 1/0 ACSR$ - 0$ - 0
Rock Hole - PoleThe installation is made in "solid" rock only$ - 0
Rock Hole - AnchorThe installation is made in "solid" rock only$ - 0
Serve GuyReserve the existing guy that has loosened or broken$ - 0
Set DeepSet pole extra deep - units are measure in feet$ - 0
Splice Neutral$ - 0
Splice Primary$ - 0
Splice Service$ - 0
Split BoltInstall a 5/8" machine bolt and 2 square washers in a pole top to prevent the pole top from splitting$ - 0
Tighten Hardware$ - 0
Transformer Hanger$ - 0$ - 0
TV Booster$ - 0$ - 0
Two-Way Feed Sign$ - 0$ - 0
Section O - Outdoor Light Assembly Units
A outdoor light assembly unit consists of the installation of a light and making required connections.
Unit NumberDescriptionLabor Unit Price
InstallRetire
M265.1Outdoor Light 100-watt HPS$ - 0$ - 0
M265.2Outdoor Light 400-watt MV$ - 0$ - 0
M265.3Outdoor Light 400-watt Roadway (Cobrahead)$ - 0$ - 0
M265.4Outdoor Light 400-watt MH Flood$ - 0$ - 0
M265.5Outdoor Light 1000-watt$ - 0$ - 0
M265.6Outdoor Light 175-watt$ - 0$ - 0
M265.9LED Outdoor Light - Residential$ - 0$ - 0
M265.11LED Roadway Large - Cobrahead$ - 0$ - 0
M265.12LED Outdoor Large - Residential$ - 0$ - 0
M265.13LED Directional Flood$ - 0$ - 0
Section R - Oil Circuit Recloser Assembly Units
An oil circuit recloser assembly unit consists of the installation of the OCR's, their protective equipment and their hardware and leads with their connectors and supporting insulators and pints (See RUS Bulletin 1728F-803 Section R)
Unit NumberDescriptionLabor Unit Price
InstallRetire
VR1.11Ø Oil Circuit Recloser$ - 0$ - 0
VR1.2Oil Circuit Recloser (with Bypass Cutout)$ - 0$ - 0
VR2.2Oil Circuit Reclosers (Two)$ - 0$ - 0
VR3.1Oil Circuit Reclosers (Three)$ - 0$ - 0
VR3.2Oil Circuit Reclosers (Three) (With Bypass Cutout)$ - 0$ - 0
VR3.213Ø VersaTech w/ Bypass$ - 0$ - 0
VR4.212Ø VersaTech w/ PKR Bypass$ - 0$ - 0
VR4.33Ø OCR PKR Bypass$ - 0$ - 0
VR4.313Ø VersaTech w/ PKR Bypass$ - 0$ - 0
OCR - 15 AmpOil Circuit Recloser - 15 Amp$ - 0$ - 0
OCR - 25 AmpOil Circuit Recloser - 25 Amp$ - 0$ - 0
OCR - 35 AmpOil Circuit Recloser - 35 Amp$ - 0$ - 0
OCR - 50 AmpOil Circuit Recloser - 50 Amp$ - 0$ - 0
OCR - 70 AmpOil Circuit Recloser - 70 Amp$ - 0$ - 0
OCR - 100 AmpOil Circuit Recloser - 100 Amp$ - 0$ - 0
Section S - Sectionalizing Assembly Units
A sectionalizing assembly unit includes the installation of all specified hardware, insulators and switches.
Unit NumberDescriptionLabor Unit Price
InstallRetire
VS1.01Cutout$ - 0$ - 0
VS1.02Single-Phase Combination Cutout$ - 0$ - 0
S1.02Combination Cutout (9 kV Arrestor)$ - 0$ - 0
VS1.1Single-Phase Cutout on Bracket$ - 0$ - 0
S1.2Single-Phase Co+B30mbination Cutout On Brkt (9 kV Arrestor)$ - 0$ - 0
VS1.2Single-Phase Combination Cutout On Brkt (18 kV Arrestor)$ - 0$ - 0
VS1.3Three-Phase Cut-outs$ - 0$ - 0
VS1.4Three-Phase Comb. Cutout on Xarm (18 kV)$ - 0$ - 0
VS2.01Single-Phase Disconnect Switch$ - 0$ - 0
VS2.21600A Disconnect Switches (Two-Phase)$ - 0$ - 0
VS2.31Disconnect Switches (Three-Phase)$ - 0$ - 0
VS2.31FDisconnect Switches on FG Crossarms$ - 0$ - 0
VS2.310Disconnect Switches (3Ø w/ 10' Crossarm)$ - 0$ - 0

RUS 790 Underground Unit Costs

Underground Construction Units
The Contractor shall construct all assembly in accordance with the Specifications and Drawings found in RUS Bulletin 1728F-806. All underground construction units shall be installed in accordance with the Florida Underground Facility Damage Prevention and Safety Act.
Section UD - Underground Cable Assembly Units
An underground cable assembly unit consists of the installation of 1,000 feet of cable and marking tape for underground primaries, secondaries and services. It does not include the plowing, trenching and backfilling, of the termination of the primary cable which are provided for on the other assembly units. It includes the labor termination, connection and sealing of the secondary and service cable and conductors as shown in the specifications and drawings, and the labor for making all primary, secondary and service cable splices. Buried cable may be spliced only when and where approved by the Engineer. In computing the compensation to the Contractor for underground cable assembly units, only the distance between stakes, paralleling the cable shall be used. The number of units so computed includes all installation of cable in all specified trenches, risers, conduits, crossings, manholes, transformers, terminal housings and meter boxes. The conductor or cables listed are the manufacturer's designation of types, size, voltage, rating and material. Primary cable shall not be installed with a bending radius of less then 12 times the overall diameter of the cable. The Contractor and the Owner shall jointly perform cable acceptance tests on installed cable in accordance with the specifications using test equipment furnished by the Contractor.
Unit NumberDescriptionLabor Unit Price
InstallRetire
350 URD AL 25 kV350 URD 25 kV Cable - 1,000'$ - 0$ - 0
500 AL 25 kV500 AL 25 kV Cable - 1,000'$ - 0$ - 0
750 AL 25 kV750 AL 25 kV Cable - 1,000'$ - 0$ - 0
1000 URD 25 kV1000 URD 25 kV Cable - 1,000'$ - 0$ - 0
1/0 URD AL 25 kV1/0 URD AL 25 kV Cable - 1,000'$ - 0$ - 0
1/0 URD AL 35 kV1/0 URD AL 35 kV Cable - 1,000'$ - 0$ - 0
(3)350 (1)4/0 USE350-350-350-4/0 Underground Service - 1,000'$ - 0$ - 0
(3)500 (1) 350 UG500-500-500-350 Underground AL Service - 1,000'$ - 0$ - 0
4/0-4/0-2/0 UG AL4/0-4/0-2/0- Triplex Underground AL Service - 1,000'$ - 0$ - 0
350-350-4/0 UG AL350-350-4/0 Triplex Underground AL Service - 1,000'$ - 0$ - 0
Section U - A,B,C - Underground Primary Terminal Pole Assembly Units
An underground primary terminal pole assembly unit consists of the cable termination and installation of all necessary brackets, protective equipment, switches, insulators and hardware. The installation of primary terminal pole assemblies shall include the cost of installing the necessary cable identification tags as directed by the Owner.
Unit NumberDescriptionLabor Unit Price
InstallRetire
UA11Ø Cable Deadend Terminal Pole$ - 0$ - 0
UA21Ø Cable Deadend Terminal Pole$ - 0$ - 0
UA31Ø Cable Tangent Terminal Pole$ - 0$ - 0
UB12Ø Cable Term. Pole With Cutouts and Crossarm Mounting Arresters$ - 0$ - 0
UB22Ø Cable Term. Pole With Cutouts and Bracket Mounting Arresters$ - 0$ - 0
UB32Ø Cable Term. Pole W/out Cutouts, With Crossarm Mounting Arresters$ - 0$ - 0
UB42Ø Cable Term. Pole W/out Cutouts, With Bracket Mounting Arresters$ - 0$ - 0
UC13Ø Cable Term. Pole With Cutouts and Crossarm Mounting Arresters$ - 0$ - 0
UC23Ø Cable Term. Pole With Cutouts and Bracket Mounting Arresters$ - 0$ - 0
UC2-13Ø Cable Deadend Terminal Pole$ - 0$ - 0
UC2-23Ø Cable Tangent Terminal Pole$ - 0$ - 0
UC5-13Ø Cable Deadend Terminal Pole With Disconnect Switches$ - 0$ - 0
UC6-13Ø Cable Tangent Terminal Pole With Disconnect Switches$ - 0$ - 0
Section UG - Underground Transformer Assembly Units
An underground transformer assembly unit consists of the installation of the transformer, its housing, warning signs, switches, over-current protective devices, grounding loop, and its hardware and leads with their connectors and supporting insulators. This unit does not include the installation of primary cable terminations, lightning arrestors, fault indicators or ground rods, nor does it include any trenching. For pad-mounted transformers, it does not include installation of the pad, drainable material, backfilling, compaction, or site preparation which are included in the pad assembly units. For submersible transformers it includes the installation of cable terminations, of the enclosure and cover, of drainable material (when specified) and the excavation. An underground transformer assembly unit does not include the installation of primary cable terminations (Elbows). Terminations will be listed on the staking sheets as individual assemblies (as required). Transformer installation labor costs should not include the cost of primary terminations as those should be represented under the appropriate termination assemblies found in Section UM.
Unit NumberDescriptionLabor Unit Price
InstallRetire
UG7$ - 0$ - 0
UG17-2$ - 0$ - 0
Section UM - Miscellaneous Underground Assembly Units
A miscellaneous underground assembly unit consists of the installation of an additional unit needed in the Project for new construction , but not otherwise listed in the Proposal. This section includes the installation of the miscellaneous assembly units as shown on the respective underground construction drawings found in the RUS Bulletin 1728F-806. Where miscellaneous units consist of or include the installation of a primary cable termination, the unit includes the preparation of the cable to accommodate the termination, the installation of the stress cone, and the connection of the cable to the terminal equipment. Pad assembly units are in this section and include the installation of the bedding, drainable material (when specified), cable slot, and site preparation, backfilling and tamping. The installation of a primary cable termination shall include the cost for installing the appropriate cable identification tags as directed by the Owner, Insert Bushings and Protective caps will be identified on the staking sheets as the appropriate miscellaneous assembly unit(s) and will be charged accordingly based on the prices submitted.
Unit NumberDescriptionLabor Unit Price
InstallRetire
UK5Secondary Pedestal Underground Cable$ - 0$ - 0
UM1-5Transformer - Plastic Pad$ - 0$ - 0
UM1-5CPad Assembly - Concrete$ - 0$ - 0
UM1-5NCPad Assembly - Non-Concrete$ - 0$ - 0
UM1-6Transformer Concrete Pad$ - 0$ - 0
UM1-6CThree-Phase Transformer Concrete Pads$ - 0$ - 0
UM1-7CGround Sleeve Assembly - Concrete$ - 0$ - 0
UM1-7NCGround Sleeve Assembly - Non-Concrete$ - 0$ - 0
UM3-14Single-Phase Sectionalizing Enclosure$ - 0$ - 0
UM5Secondary Cable Terminal Pole$ - 0$ - 0
UM6-1Load Break Elbow (200A)$ - 0$ - 0
UM6-4Fault Indicator$ - 0$ - 0
UM6-5Feed Through Load Break Elbow$ - 0$ - 0
UM6-6Ground Rod Assembly$ - 0$ - 0
UM6-7Bushing Well Plug (200A)$ - 0$ - 0
UM6-9Conduit Cable Riser$ - 0$ - 0
UM6-10Insulated Protective Cap (200A)$ - 0$ - 0
UM6-11Insulated Protective Cap (600A)$ - 0$ - 0
UM6-12Cable Marker Assembly$ - 0$ - 0
UM6-15Stand-Off Insulator (200A)$ - 0$ - 0
UM6-17Insulating Plug 600 Amp Connector$ - 0$ - 0
UM6-19Stand-Off Feed Through (200A)$ - 0$ - 0
UM6-20Two Point Junction (200A)$ - 0$ - 0
UM6-21Three Point Junction (200A)$ - 0$ - 0
UM6-22Four Point Junction (200A)$ - 0$ - 0
UM6-24Outdoor Termination$ - 0$ - 0
UM6-28In Line Primary Splice$ - 0$ - 0
UM6-34Dead Break Elbow Surge Arrestor$ - 0$ - 0
UM6-35Cut-out Arrestor Combination$ - 0$ - 0
UM8Meter Installation Underground Source$ - 0$ - 0
UM8-2Meter Pedestal Wood Post$ - 0$ - 0
UM8-3Trough Type Meter Pedestal$ - 0$ - 0
UM12Cable Route Warning Sign$ - 0$ - 0
Section UR - Underground Excavation Assembly Units
UR2-S(D&W) Trenching Assembly Unit, Soil - Consists of one (1) lineal foot of trenching in soil, measured parallel to the surface of the ground, to a specified depth (D) and width (W), in inches, including the excavation, and backfilling and compacting. This unit includes all labor required in the repair and/or replacement of streets, roads, drives, fences, lawns, shrubbery, water mains, pipes, pipelines and contents, underground power and telephone facilities, buried sewerage and drainage facilities, and any other property damaged by the trenching, except as specifically provided for in other units. NOTE: Where the guidelines set forth by the Florida Utility Damage Prevention Act do not allow plowing and hand digging is required, this units will be suffixed by the letter "T".
UR-R(D&W) Trenching Assembly Unit, Rock - Consists of one (1) lineal foot of trenching in rock, measured parallel to the surface of the ground, to a specified depth (D) and width (W), in inches, including the excavation, and backfilling and compacting to place cable to the depth specified in the Specifications. This unit will be specified by the Owner only when field conditions at the site show the existence of rock at a depth preventing the compacting of the cable in soil to the depths required in the Specifications. This unit includes all labor required in the repairs and/or replacement of streets, roads, drives, fences, lawns, shrubbery, water mains, pipes, pipelines and contents, underground power and telephone facilities, buried sewerage and drainage facilities, and any other property damaged by the trenching, except as specifically provided for in other units. This unit does not include underground cable facilities installed in the trench or cable bedding assembly units, when required.
UR-3 Cable Bedding Assembly Unit - Consists of the installation of one (1) lineal foot of a 2-inch bed of clean sand or soil placed in the trench under the cable and a 4-inch layer of clean sand and soil backfill over the cable to the width of the trench. NOTE: The exact location and number of units shall be determined by the Owner after the trenches are open in those areas where rock or other conditions make special bedding necessary.
UR-5 (Pipe Diameter) Underground Pipe Crossing Assembly (Directional Bore) - Consists of the installation of one (1) lineal foot of steel pipe or conduit, of the inside diameter, in inches, specified in the last digit of the assembly unit designation, installed in place. This unit includes the directional bore, installation of the pipe or conduit, and any excavation, backfilling and tamping necessary for the installation. The pipe or conduit will be installed at the depth specified by the Owner. The installation of the underground cable in the pipe is not included in this unit.
UR-5C Conduit Installation Assembly Unit - Consists of the installation of one (1) lineal foot of steel pipe or conduit, of the inside diameter, in inches, specified, in the last digit, of the assembly unit designation installed in place.
Section UR - Underground Excavation Assembly Units (continued)
Unit NumberDescriptionLabor Unit Price
InstallRetire
UR2-S (6X36)1'x6"X36" Trenching Unit, Soil$ - 0$ - 0
UR2-R (6X36)1'x6"X36" Trenching Unit, Rock$ - 0$ - 0
UR2-S (6X48)1'X6"x48" Trenching Unit, Soil$ - 0$ - 0
UR2-S (6X60)1'X6"x60" Trenching Unit, Soil$ - 0$ - 0
UR2-NT (12X36)1'X12"X36" Normal Trench Unit, Dug With Backhoe$ - 0$ - 0
UR2-NT (12X48)1'X12"X48" Normal Trench Unit, Dug With Backhoe$ - 0$ - 0
UR2-NT (12X60)1'X12"X60" Normal Trench Unit, Dug With Backhoe$ - 0$ - 0
UR2-NT(24X48)1'X24"X48" Normal Trench Unit, Dug With Backhoe$ - 0$ - 0
UR2-NT (36X48)1'X36"X48" Normal Trench Unit, Dug With Backhoe$ - 0$ - 0
UR2-NT (36X60)1'X36"X60" Normal Trench Unit, Dug With Backhoe$ - 0$ - 0
UR2-T (12X48)1'X12"X48" Normal Trench in Rock Unit, Dug With Backhoe$ - 0$ - 0
UR-31' Cable Bedding Assembly Unit$ - 0$ - 0
UR-5(2)1'X2" Diameter Directional Bore$ - 0$ - 0
UR-5(3)1'X3" Diameter Directional Bore$ - 0$ - 0
UR-5(4)1'X4" Diameter Directional Bore$ - 0$ - 0
UR-5(5)1'X5" Diameter Directional Bore$ - 0$ - 0
UR-5(6)1'x6" Diameter Directional Bore$ - 0$ - 0
UR-5C(2)1'X2" Diameter Conduit$ - 0$ - 0
UR-5C(3)1'X3" Diameter Conduit$ - 0$ - 0
UR-5C(4)1'X4" Diameter Conduit$ - 0$ - 0
UR-5C(5)1'X5" Diameter Conduit$ - 0$ - 0
UR-5C(6)1'X6" Diameter Conduit$ - 0$ - 0

RUS 790 Pole Replacement

Overhead Construction Units - Energized at 14.4 / 24.9 kV
The Contractor shall construct all assembly in accordance with the Specifications and Drawings found attached to this contract. The Contractor will install will at its own expense any units that are not shown on the staking sheet and temporarily constructed by him to aid in construction.
Section 1 - Pole Units
A pole unit consists of the installation of one pole, one "TCEC" identification tag as indicated on the staking sheet. It does not include the pole-top assembly unit or other parts attached to the pole. The first two digits indicate the length of the pole; the third digits shows the classification per A.S.A. (Example: 40/4 or 40-4 means a 40 ft class 4 pole).
Unit NumberDescriptionLabor Unit Price
InstallRetire
2525 Foot Long Pole$ - 0$ - 0
3030 Foot Long Pole$ - 0$ - 0
3535 Foot Long Pole$ - 0$ - 0
4040 Foot Long Pole$ - 0$ - 0
4545 Foot Long Pole$ - 0$ - 0
5050 Foot Long Pole$ - 0$ - 0
5555 Foot Long Pole$ - 0$ - 0
6060 Foot Long Pole$ - 0$ - 0
6565 Foot Long Pole$ - 0$ - 0
7070 Foot Long Pole$ - 0$ - 0
5555 Foot Steel Pole$ - 0
6060 Foot Steel Pole$ - 0
7070 Foot Steel Pole$ - 0
7575 Foot Steel Pole$ - 0
TPTop Pole$ - 0
RNPRenumber Pole$ - 0
Section 2 - Conductor Assembly Units
A conductor assembly unit consists of 1,000 feet of conductor or cable for primaries, secondary's or service and includes tie wires, sleeves for splicing, connectors, and armor rods with clips and armor wire when necessary. Tree trimming necessary for installing the services and secondary's on poles not carrying the primary line is included with the conductor assembly unit and shall be performed in accordance with the directions of the Engineer. The service shall be connected to the secondary or transformer and 2 feet of conductor or cable shall be left for connecting to the consumer's service entrance. In computing the compensation to the Bidder for conductor assembly units only the horizontal distance between conductor supports or poles staked shall be used. The conductor or cable sized and types listed are the manufacture's designation.
Unit NumberDescriptionLabor Unit Price
InstallRetire
2 ACSR#2 Aluminum Clad Steel Reinforced (Sparrow)$ - 0$ - 0
4 ACSR#4 Aluminum Clad Steel Reinforced (Swante)$ - 0$ - 0
1/0 ACSR#1/0 Aluminum Clad Steel Reinforced (Raven)$ - 0$ - 0
3/0 ACSR#3/0 Aluminum Clad Steel Reinforced (Pigeon)$ - 0$ - 0
266.8 ACSR#266.6 MCM Aluminum Clad Steel Reinforced (Waxwing)$ - 0$ - 0
336 ACSR#336 MCM Aluminum Clad Steel Reinforced (Merlin)$ - 0$ - 0
6 BHD CU#6 Bare Hard Drawn Copper$ - 0
4 BHD CU#4 Bare Hard Drawn Copper$ - 0
2-3 STR CU#2/3 Strand Copper$ - 0
9-1/2D CU#9-1/2D Copper$ - 0
4-2 AL#4/2 Duplex Aluminum Service Overhead$ - 0$ - 0
6-2 AL#6/2 Duplex Aluminum Service Overhead$ - 0$ - 0
2-3 AL#2/3 Triplex Aluminum Service Overhead$ - 0$ - 0
4-3 AL#4/3 Triplex Aluminum Service Overhead$ - 0$ - 0
1/0-3 AL#1/0-3 Triplex Aluminum Service Overhead$ - 0$ - 0
3/0-3 AL#3/0-3 Triplex Aluminum Service Overhead$ - 0$ - 0
4/0-3 AL#4/0-3 Triplex Aluminum Service Overhead$ - 0$ - 0
2-4 AL#2-4 Triplex Aluminum Service Overhead$ - 0$ - 0
1/0-4 AL#1/0-4 Triplex Aluminum Service Overhead$ - 0$ - 0
3/0-4 AL#3/0-4 Triplex Aluminum Service Overhead$ - 0$ - 0
4/0-4 AL#4/0-4 Triplex Aluminum Service Overhead$ - 0$ - 0
336.4 AL#336.6 Triplex Quadruplex Service Overhead$ - 0$ - 0
1/0 CU#1/0 Copper$ - 0
Overhead Construction Units - Energized at 14.4 / 24.9 kV
A pole top assembly unit consists of the installation of the hardware, crossarms and their appurtenances, insulators, etc. required to support the primary and neutral conductors. It does not include the pole.
Section A - Single-Phase Primary Pole Top Assembly Units
Unit NumberDescriptionLabor Unit Price
InstallRetire
VA1.0Single Support - Miscellaneous$ - 0$ - 0
VA1.01Single Support - Miscellaneous$ - 0$ - 0
VA1.011Single Support - Miscellaneous$ - 0$ - 0
VA1.011LSingle Support - Miscellaneous$ - 0$ - 0
VA1.011PSingle Support - Miscellaneous (Post Insulators)$ - 0$ - 0
VA1.01PSingle Support - Miscellaneous (Post Insulators)$ - 0$ - 0
VA1.04NPSingle Support - Miscellaneous$ - 0$ - 0
VA1.1Single Support - Tangent$ - 0$ - 0
VA1.1PSingle Support - (Tangent) (Post Insulators)$ - 0$ - 0
VA1.11Single Support - Tangent on Crossarm$ - 0$ - 0
VA1.11PSingle Support on Crossarm (Post Insulators)$ - 0$ - 0
VA1.2Single Support - Tangent$ - 0$ - 0
VA1.2PSingle Support - (Tangent) (Post Insulators)$ - 0$ - 0
VA1.3Single Support$ - 0$ - 0
VA1.3PSingle Support (Post Insulators)$ - 0$ - 0
VA2.0Double Support - Miscellaneous$ - 0$ - 0
VA2.01Double Support - Miscellaneous$ - 0$ - 0
VA2.01PDouble Support - Miscellaneous (Post Insulators)$ - 0$ - 0
VA2.021Double Support - Miscellaneous$ - 0$ - 0
VA2.021PDouble Support - Miscellaneous (Post Insulators)$ - 0$ - 0
VA2.1Double Support - Shallow Angle$ - 0$ - 0
VA2.1PDouble Support (Post Insulators)$ - 0$ - 0
VA2.21Double Support On Crossarms$ - 0$ - 0
VA3.1Suspension Angle - Angle Shoe Neutral$ - 0$ - 0
VA3.2Suspension Angle$ - 0$ - 0
VA3.3Suspension Angle - Swinging Clevis Neutral$ - 0$ - 0
VA4.1Dead End Angle (90⁰-150⁰)$ - 0$ - 0
VA4.2Dead End Angle (20⁰-90⁰)$ - 0$ - 0
VA5.1Single Dead End$ - 0$ - 0
VA5.2Single Dead End$ - 0$ - 0
VA5.21Single Dead End on Crossarms$ - 0$ - 0
VA5.3Single Dead End - Miscellaneous$ - 0$ - 0
VA5.31Single Dead End on Crossarms$ - 0$ - 0
VA5.4Single Dead End - Miscellaneous$ - 0$ - 0
VA5.71FSingle Dead End on FG Crossarm$ - 0$ - 0
VA6.1Double Dead End (Straight)$ - 0$ - 0
VA6.2Double Dead End (Feed Through)$ - 0$ - 0
VA6.21Double Dead End On Crossarms$ - 0$ - 0
VA6.41Double Dead End on Fiberglass Crossarms$ - 0$ - 0
Section B - Two-Phase Primary Pole Top Assembly Units
Unit NumberDescriptionLabor Unit Price
InstallRetire
VB1.7NPNarrow Profile with Post Insulator$ - 0$ - 0
VB1.11Single Support on Crossarm (Tangent)$ - 0$ - 0
VB1.11PSingle Support on Crossarm (Tangent) (Post Insulators)$ - 0$ - 0
VB1.12Single Support on Crossarm (Tangent)$ - 0$ - 0
VB1.12PSingle Support on Crossarm (Tangent) (Post Insulators)$ - 0$ - 0
VB1.13Single Support on Crossarm$ - 0$ - 0
VB1.13PSingle Support on Crossarm (Post Insulators)$ - 0$ - 0
VB1.14Single Support, Neutral on Crossarm$ - 0$ - 0
VB1.14PSingle Support, Neutral on Crossarm (Post Insulators)$ - 0$ - 0
VB2.21Double Support on Crossarm (Shallow Angle)$ - 0$ - 0
VB2.21PDouble Support on Crossarms (Post Insulators)$ - 0$ - 0
VB2.22Double Support Neutral on Crossarms (Shallow Angle)$ - 0$ - 0
VB2.22PDouble Support, Neutral on Crossarms (Post Insulators)$ - 0$ - 0
VB2.9NPNarrow Profile Post Insulator with Angle$ - 0$ - 0
VB3.1Suspension Angle - Angle Shoe Neutral$ - 0$ - 0
VB4.1Dead End Angle (90⁰-150⁰)$ - 0$ - 0
VB5.1Single Dead End - Vertical$ - 0$ - 0
VB5.21Single Dead End on Crossarms$ - 0$ - 0
VB5.31Single Dead End on Crossarms$ - 0$ - 0
VB5.71FSingle Dead End on Fiberglass Crossarms$ - 0$ - 0
VB5.71FDSingle Dead End on Fiberglass Crossarms$ - 0$ - 0
VB6.21Double Dead End on Crossarms$ - 0$ - 0
VB6.41Suspension Support Double Dead End on FG Crossarm$ - 0$ - 0
Section C - Three-Phase Primary Pole Top Assembly Units
Unit NumberDescriptionLabor Unit Price
InstallRetire
VC1.7NNarrow Profile Post Insulator$ - 0$ - 0
VC1.1NPSingle Support NP Back-To-Back$ - 0$ - 0
VC1.11Single Support on Crossarm (Tangent)$ - 0$ - 0
VC1.11FSingle Support on Tangent on 8' FG Crossarm$ - 0$ - 0
VC1.11LSingle Support on Crossarm (Tangent) (Large Conductor)$ - 0$ - 0
VC1.11PSingle Support on Crossarm (Tangent) (Post Insulators)$ - 0$ - 0
VC1.11PLSingle Support on Crossarm (Tangent( (PI)(LG)$ - 0$ - 0
VC1.12Single Support on Crossarm (Tangent)$ - 0$ - 0
VC1.12LSingle Support on Crossarm (Tangent) (Large Conductor)$ - 0$ - 0
VC1.12PSingle Support on Crossarm (Tangent) (Post Insulators)$ - 0$ - 0
VC1.13Single Support on Crossarm$ - 0$ - 0
VC1.13LSingle Support on Crossarm (Large Conductors)$ - 0$ - 0
VC1.13PSingle Support on Crossarm (Post Insulators)$ - 0$ - 0
VC1.41Single Support Neutral on Crossarm$ - 0$ - 0
VC1.41FSingle Support Neutral on FG Crossarm$ - 0$ - 0
VC1.41LSingle Support Neutral on Crossarm (Large Conductor)$ - 0$ - 0
VC1.41PSingle Support, Neutral on Crossarm (Post Insulators)$ - 0$ - 0
VC1.42FSingle Support Tangent on FG Crossarm (Post Insulators)$ - 0$ - 0
VC1.42PSingle Support Tangent on FG Crossarm (Post Insulators)$ - 0$ - 0
VC2.21Double Support on Crossarm$ - 0$ - 0
VC2.21FDouble Support on FG Crossarms$ - 0$ - 0
VC2.21LDouble Support on Crossarm (Shallow Angle) (Large Conductors)$ - 0$ - 0
VC2.21PDouble Support on Crossarms (Post Insulators)$ - 0$ - 0
VC2.51Double Support Neutral on Crossarms$ - 0$ - 0
VC2.51FDouble Support Neutral on 2 FG Crossarms$ - 0$ - 0
VC2.51LDouble Support Neutral on Crossarms (Large Conductor)$ - 0$ - 0
VC2.51PDouble Support, Neutral on Crossarms (Post Insulators)$ - 0$ - 0
VC2.52Double Support on 10 Foot Crossarms$ - 0$ - 0
VC2.52FDouble Support on FG Crossarms$ - 0$ - 0
VC2.52LDouble Support on 10 Foot Crossarms (Large Conductor)$ - 0$ - 0
VC2.52PDouble Support on 10-Foot Crossarms (Post Insulators)$ - 0$ - 0
VC2.9NPSingle Support Narrow Profile Vertical Angle$ - 0$ - 0
VC3.1Suspension Angle - Angle Shoe Neutral$ - 0$ - 0
VC3.2LSuspension Angle (Large Conductor) - Angle Shoe Neutral$ - 0$ - 0
VC4.1Dead End Angle (Acute)$ - 0$ - 0
VC4.2LDead End Angle (Large Conductor)$ - 0$ - 0
VC5.1Single Dead End - Vertical - (Large Conductor) Dead End Shoe Neutral$ - 0$ - 0
VC5.2LSingle Dead End - Vertical - (Large Conductor) Dead End Shoe Neutral$ - 0$ - 0
VC5.21Single Dead End on 2 Crossarms$ - 0$ - 0
VC5.21FSingle Dead End on 2 FG Crossarms$ - 0$ - 0
VC5.31Single Dead End on 3 Crossarms$ - 0$ - 0
VC5.41FSuspension Support on 10' FG Crossarm$ - 0$ - 0
VC5.71Single Dead End on Crossarm$ - 0$ - 0
VC5.71F3PH Susp Supp Sing DE on FG Crossarm$ - 0$ - 0
VC6.21Double Dead End on 2 Crossarms$ - 0$ - 0
VC6.21FSuspension Support on Double DE on FG Crossarms$ - 0$ - 0
VC6.31Double Dead End on 3 Crossarms$ - 0$ - 0
VC6.41Double Dead End on 10 Foot Crossarms$ - 0$ - 0
VC6.51Double Dead End on 10 Foot Crossarms$ - 0$ - 0
VC6.51FSuspension Support on Double DE on 10' FG Crossarms$ - 0$ - 0
Section D - Double-Circuit Primary Pole Top Assembly Units
Unit NumberDescriptionLabor Unit Price
InstallRetire
VD1.81Single Support on Crossarms (Tangent)$ - 0$ - 0
VD1.81LSingle Support on Crossarms (Tangent) (Large Conductors)$ - 0$ - 0
VD1.81PSingle Support on Crossarms (Tangent) (Post Insulators)$ - 0$ - 0
VD1.82Single Support on Crossarms (Tangent)$ - 0$ - 0
VD1.82LSingle Support on Crossarms (Tangent) (Large Conductors)$ - 0$ - 0
VD1.82PSingle Support on Crossarms (Tangent) (Post Insulators)$ - 0$ - 0
VD1.83Single Support on Crossarms$ - 0$ - 0
VD1.83LSingle Support on Crossarms (Tangent) (Large Conductors)$ - 0$ - 0
VD1.83PSingle Support on Crossarms (Post Insulators)$ - 0$ - 0
VD1.91Double Support on Crossarms$ - 0$ - 0
VD2.91LDouble Support on Crossarms (Shallow Angle) (Large Conductors)$ - 0$ - 0
VD2.91PDouble Support on Crossarms (Post Insulators)$ - 0$ - 0
VD5.71FDouble Dead Ends on FG Crossarms$ - 0$ - 0
VD6.91Double Dead Ends on Crossarms (Feed Through)$ - 0$ - 0
Section E - Guying Assembly Units
A guy assembly unit consists of the hardware, wire guy marker. An overhead guy does not include the associated pole or down guy, each of which is listed separately.
Unit NumberDescriptionLabor Unit Price
InstallRetire
E1.018M Single OH Guy$ - 0$ - 0
E1.18M Single Down Guy$ - 0$ - 0
E12.28M Spread Down Guy / Inline Type$ - 0$ - 0
E12.312.5M Spread Down Guy / Inline Type$ - 0$ - 0
E13.28M Spread Down Guy / Offset Angle$ - 0$ - 0
E13.312.5M Spread Down Guy / Offset Angle$ - 0$ - 0
E2.0112.5M Single Down Guy$ - 0$ - 0
E2.112.5M Single OH Guy$ - 0$ - 0
E3.1Single Dow Guy Wrapped$ - 0$ - 0
E3.10Guy Marker$ - 0$ - 0
E5.1G36Guy Strain Insulator 36"$ - 0$ - 0
E5.1G54Guy Strain Insulator 54"$ - 0$ - 0
E5.1G78Guy Strain Insulator 78"$ - 0$ - 0
Section F - Anchor Assembly Units
An anchor assembly units consists of the installation of an anchor with rod complete and ready for attaching to the guy wire.
Unit NumberDescriptionLabor Unit Price
InstallRetire
F2.8Anchor Screw 8" (Power Installed)$ - 0$ - 0
F2.10Anchor Screw 10" (Power Installed)$ - 0$ - 0
F2.15Anchor Screw 15" (Power Installed)$ - 0$ - 0
F7.2Double Helix Anchor$ - 0$ - 0
F7.3Triple Helix Anchor$ - 0$ - 0
Anchor Ext.Anchor Extension$ - 0$ - 0
Section G - Transformer Assembly Units
A transformer assembly unit consists of the installation of the transformer, its protective equipment and its hardware and leads with their connectors and supporting insulators and pints. This unit does not include the installation of the pole top, secondary, service or grounding assemblies.
Unit NumberDescriptionLabor Unit Price
InstallRetire
VG1.2/VG1.3 - 33 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.2/VG1.3 - 55 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.2/VG1.3 - 77 1/2 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.2/VG1.3 - 1010 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.2/VG1.3 - 1515 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.2/VG1.3 - 2525 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.2/VG1.3 - 3737 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.2/VG1.3 - 5050 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.2/VG1.3 - 7575 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.2/VG1.3 - 100100 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.2/VG1.3 - 167167 KVA 1Ø Transformer (Deadend or Tangent)$ - 0$ - 0
VG1.4/VG1.5 - 33 KVA 1Ø Transformer (Tangent)$ - 0$ - 0

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .