20260923 Drawings.pdf
PDF 518 KB Posted
- Attached to
- Radio Communications Upgrade Project
- Solicitation number
- S-24800-00018354
- Issued by
- Oregon
About this file
Summary
This is a structural drawing set prepared by Miller Consulting Engineers, Inc. for the Oregon Military Department's Operations Facility Antenna Installation project located at 1921 Turner Road SE, Salem, Oregon. The project involves the design of three new antenna support structures to be attached to an existing building. The structural drawings include a cover sheet, structural notes and special inspection requirements, building plan, elevation view, and steel details. The project is based on the 2025 Oregon Structural Specialty Code (OSSC) and the 2024 International Building Code (IBC). The antenna mounts are positioned 25 feet from the top of the roof and include bracing systems using C6x13 channels across two bays, W8x10 outriggers, and custom steel details for connection to the existing building structure.
The structural design incorporates wind design parameters with a basic design wind speed of 96 miles per hour and seismic design data appropriate for Risk Category II structures. All structural steel fabrication, welding, and erection must conform to AISC 360 specifications, with quality assurance and quality control documentation required per AISC 360 and AISC 341. Special inspections and non-destructive testing are required for welded connections, fasteners, and structural steel items in accordance with Section 1705 of the building code. An approved independent inspection agency meeting ASTM E329 standards must perform all special inspections, with welding inspectors qualified per AWS D1.1. The structural engineer of record is Eric Watson, PE (Oregon #51043), and the permit set was issued on September 23, 2026.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFQ 250020C001 final for posting.pdf | ||
| Ant 10515-0578-4100.pdf | ||
| Antenna Project - AASF1.pdf | ||
| 20260923 Calculations.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
# NUMBER OR POUNDS
AB ANCHOR BOLT
ACI AMERICAN CONCRETE INSTITUTE
ADDL ADDITIONAL
ADJ ADJACENT
AESS ARCHITECTURALLY EXPOSED STRUCTURAL
STEEL
AFF ABOVE FINISH FLOOR
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALT ALTERNATE
ALUM ALUMINUM
APA AMERICAN PLYWOOD ASSOCIATION
APPROX APPROXIMATELY
ARCH ARCHITECTURAL
ASTM AMERICAN SOCIETY FOR TESTING AND
MATERIALS
ASD ALLOWABLE STRESS DESIGN
ASSY ASSEMBLY
ATR ALL THREAD ROD
ATR/A ALL THREAD ROD WITH ADHESIVE
AWS AMERICAN WELDING SOCIETY
B/ BOTTOM OF
BF BRACED FRAME
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BN BOUNDARY NAIL
BOT BOTTOM
BRBF BUCKLING RESTRAINED BRACED FRAME
BRNG BEARING
BSMT BASEMENT
BTWN BETWEEN
BU BUILT-UP
C CAMBER OR CHANNEL (AMERICAN STANDARD)
CANT CANTILEVER
CFS COLD-FORMED STEEL
CIP CAST IN PLACE
CG CENTER OF GRAVITY
CGS CENTER OF GRAVITY OF (PRESTRESSING) STEEL
CJ CONTROL OR CONSTRUCTION JOINT
CJP COMPLETE JOINT PENETRATION
CL CENTERLINE
CLG CEILING
CLR CLEARANCE; CLEAR
CLSM CONTROLLED LOW STRENGTH MATERIAL
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
COORD COORDINATE
CSA CONCRETE SCREW ANCHOR
d PENNY (NAIL) db NOMINAL BAR DIAMETER
DBA DEFORMED BAR ANCHOR
DBL DOUBLE
DBO DESIGNED BY OTHERS
DEG DEGREE
DEMO DEMOLISH; DEMOLITION
DF/L DOUGLAS FIR-LARCH
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DIST DISTANCE
DL DEAD LOAD
DN DOWN
DP DEPTH OR DEEP
DTL DETAIL
DWG DRAWING
(E) EXISTING
E MODULUS OF ELASTICITY
EA EACH
EB EXPANSION BOLT
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
EN EDGE NAIL
EOR ENGINEER OF RECORD
EQ EQUAL; EARTHQUAKE
EW EACH WAY
EXT EXTERIOR
EXTD EXTEND; EXTENDED
f'c 28 DAY CONC COMPRESSIVE STRENGTH f'm MASONRY NET AREA COMPRESSIVE STRENGTH Fy YIELD STRESS Fu TENSILE STRESS
F/ FACE OF
FAB FABRICATED / FABRICATOR
FF FINISH FLOOR
FN FIELD NAIL
FLR FLOOR
FDN FOUNDATION
FRT FIRE RETARDANT TREATED
FS FAR SIDE
FT FEET
FTG FOOTING
GA GAUGE
GAF GAS ACTUATED FASTENER
GALV GALVANIZED
GLB GLUE LAMINATED BEAM
GR GRADE
GWB GYPSUM WALL BOARD
GYP GYPSUM
HD HOLDOWN
HDG HOT-DIP GALVANIZED
HDR HEADER
HEX HEXAGONAL
HF HEM-FIR
HGR HANGER
HORIZ HORIZONTAL
HSA HEADED STUD ANCHOR
HSS HOLLOW STRUCTURAL SECTION
HT HEIGHT
HVAC HEATING VENTILATION AIR CONDITIONING
IBC INTERNATIONAL BUILDING CODE
ICF INSULATED CONCRETE FORMS
ID INSIDE DIAMETER
IN INCH
INFO INFORMATION
INT INTERIOR
JST JOIST
JT JOINT
K KIP(S) (1,000 POUNDS)
KSF KIPS PER SQUARE FOOT
KSI KIPS PER SQUARE INCH
L, 2L ANGLE OR DOUBLE ANGLE
LAT LATERAL
LB POUND
LF LINEAR FOOT
LG LIGHT GAUGE
LL LIVE LOAD
LLBB LONG LEGS BACK TO BACK
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG LONGITUDINAL
LRFD LOAD AND RESISTANCE FACTOR DESIGN
LSL LAMINATED STRAND LUMBER
LSH LONG SLOTTED HOLE
LVL LAMINATED VENEER LUMBER
LWC LIGHT WEIGHT CONCRETE
MANUF MANUFACTURER
MAX MAXIMUM
MC MISCELLANEOUS CHANNEL
MECH MECHANICAL
MF MOMENT FRAME
MFR MANUFACTURER
MEP MECHANICAL, ELECTRICAL, PLUMBING
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MSA MASONRY SCREW ANCHOR
MT MAGNETIC PARTICLE TESTING
MTL METAL
(N) NEW
NDT NON-DESTRUCTIVE TESTING
NIC NOT IN CONTRACT
NOM NOMINAL
NS NEAR SIDE
NTE NOT TO EXCEED
NTS NOT TO SCALE
NWC NORMAL WEIGHT CONCRETE
OC ON CENTER
OCBF ORDINARY CONCENTRIC BRACED FRAME
OD OUTSIDE DIAMETER
OMF ORDINARY MOMENT FRAME
OPP OPPOSITE
OWJ OPEN WEB JOIST
PAF POWER ACTUATED FASTENER
PC PRECAST
PCF POUNDS PER CUBIC FOOT
PERP PERPENDICULAR
PJP PARTIAL JOINT PENETRATION
PL PLATE
PLF POUNDS PER LINEAL FOOT
PLWD PLYWOOD
PSI POUNDS PER SQUARE INCH
PSF POUNDS PER SQUARE FOOT
PSL PARALLEL STRAND LUMBER
PT PRESSURE TREATED
P/T POST TENSIONED
PVC POLYVINYL CHLORIDE
QTY QUANTITY
RAD RADIUS
RBS REDUCED BEAM SECTION
REF REFERENCE
REINF REINFORCING
REQD REQUIRED
RET RETAINING
REV REVISED, REVISION
RO ROUGH OPENING
SC SLIP CRITICAL
SCBF SPECIAL CONCENTRIC BRACE FRAME
SCH SCHEDULE
SEOR STRUCTURAL ENGINEER OF RECORD
SFRS SEISMIC FORCE RESISTING SYSTEM
SHT SHEET
SHTG SHEATHING
SIM SIMILAR
SLBB SHORT LEGS BACK TO BACK
SMF SPECIAL MOMENT FRAME
SMS SHEET METAL SCREW
SOG SLAB ON GRADE
SOMD SLAB ON METAL DECK
SQ SQUARE
SS STAINLESS STEEL
SSH SHORT SLOTTED HOLE
STD STANDARD
STL STEEL
SQ SQUARE
SYM SYMMETRICAL
T/ TOP OF
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
THRD THREADED
TPL TRIPLE
TRANS TRANSVERSE
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
URM UNREINFORCED MASONRY
UT ULTRASONIC TEST
VERT VERTICAL
VIF VERIFY IN FIELD
W/ WITH
W/O WITHOUT
WD WOOD
WF WIDE FLANGE
WP WORK POINT
WT WEIGHT
WWR WELDED WIRE REINFORCING
STRUCTURAL
DRAWING SYMBOLS
DETAIL REFERENCE
DETAIL SECTION CUT
BUILDING OR
WALL SECTION
CUT
ELEVATION OF
WALL OR FRAME
REVISION SYMBOL
GRID LINES
ROTATE VIEW SYMBOL
NORTH ARROW
SURFACE - STEPPED
SURFACE - SLOPE UP
SURFACE - SLOPE DOWN
SURFACE - SLOPE
TWO DIRECTIONS
DECKING SPAN
DIRECTION
OPENING IN FLOOR / WALL
EXTENT OF
ELEMENT
INDICATES
ELEMENT
CONTINUES
-NORTH-
S4.1
S3.1
S8.1
S8.1
STRUCTURAL ABBREVIATIONS
A
CONCRETE
EARTH
COMPACTED
STRUCTURAL FILL
MASONRY
SAND OR GROUT
WOOD SHEATHING - SECTION
WOOD - PLAN
STRUCTURAL
MATERIAL PATTERNS
REPEATING
FRAMING
G
IR
D E
R
STEEL
STRUCTURAL
ELEMENT
END OF
REPEATING
ELEMENT
REPEATING
FRAMING
CONTINUES
G
IR
D E
R B
E A
R
IN
G W
A L L
FRAMING
CONNECTION
SYMBOL
SURFACE EXTENTS
TYPICAL FRAMING
SCOPE OF WORK:
THE FOLLOWING PLANS ARE FOR THE DESIGN OF (3) NEW
ANTENNA SUPPORTS ATTACHED TO THE EXISTING BUILDING. THE
EXISTING BUILDING WAS DESIGNED BY OTHERS.
PROJECT DESIGN TEAM:
MILLER CONSULTING ENGINEERS, INC
STRUCTURAL ENGINEER OF RECORD
PRIMARY CONTACT: ERIC WATSON, eric@miller-se.com
SHEET
9600 SW Oak St | Suite 400 Portland, OR | 97223
503.246.1250 | miller-se.com
MCE PROJ #:
SHEET CONTENT
ISSUE DATE:
CHECKED BY:
© MILLER CONSULTING ENGINEERS
CONSULTING
MILLER
ENGINEERS
DESIGNED BY:
ISSUANCE:
S0.01
OPERATIONS
FACILITY ANTENNA
INSTALLATION
OREGON MILITARY
DEPARTMENT
1921 TURNER RD SE
SALEM, OREGON
COVER SHEET
260572
09.23.2026
PERMIT SET
STRUCTURAL DRAWING INDEX
SHEET # SHEET NAME P
E
R M
IT
S
E T
S0.01 COVER SHEET ●
S0.02 STRUCTURAL NOTES & SPECIAL INSPECTION ●
S1.01 BUILDING PLAN ●
S3.01 ELEVATION ●
S6.01 STEEL DETAILS ●
NOT TO SCALES0.01 |1 VICINITY MAP-NORTH-
REV DESCRIPTION DATE
CCS
ERW
OREGON
J
A
N
U
A
R
Y
E
N
G
I N
E
E
R
51043
R
E
G
I
S
T
E
R
E
D
PR
O
F
E
S
S
I
O
N
A
L
E
R
I
C
R
. W
A
T
S
O
N
S
T
R
U
C T
U
R
A
L
EXPIRES: 06 - 30 - 2028
DIGITALLY SIGNED
STATEMENT OF SPECIAL INSPECTION NOTES:
1. SPECIAL INSPECTIONS SHALL CONFORM TO SECTION 1705 OF THE 2019 OSSC, CONTRACT DOCUMENTS AND APPROVED SUBMITTALS. REFER TO SPECIAL INSPECTION AND TESTING TABLES FOR PROJECT REQUIREMENTS.
2. SPECIAL INSPECTIONS AND ASSOCIATED TESTING SHALL BE PERFORMED BY AN APPROVED ACCREDITED INDEPENDENT AGENCY MEETING THE REQUIREMENTS OF ASTM E329 (MATERIALS). THE INSPECTION AND TESTING AGENCY SHALL FURNISH TO THE STRUCTURAL ENGINEER A COPY OF THEIR SCOPE OF ACCREDITATION. SPECIAL INSPECTORS SHALL BE APPROVED BY THE BUILDING OFFICIAL. WELDING INSPECTORS SHALL BE QUALIFIED PER SECTION 6.1.4.1(1) OF AWS D1.1.
3. THE SPECIAL INSPECTOR SHALL OBSERVE THE INDICATED WORK FOR COMPLIANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS. ALL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTOR FOR
CORRECTION AND NOTED IN THE INSPECTION REPORTS.
4. THE SPECIAL INSPECTOR AND GEOTECHNICAL ENGINEER SHALL FURNISH INSPECTION REPORTS FOR EACH INSPECTION TO THE BUILDING OFFICIAL, STRUCTURAL ENGINEER, ARCHITECT, CONTRACTOR AND OWNER. THE SPECIAL INSPECTION AGENCY SHALL SUBMIT A FINAL REPORT STATING THAT THE WORK REQUIRING SPECIAL INSPECTION WAS INSPECTED AND IS IN CONFORMANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS AND THAT ALL DISCREPANCIES NOTED IN
THE INSPECTION REPORTS HAVE BEEN CORRECTED.
5 QUALITY ASSURANCE (QA) IS REQUIRED FOR STRUCTURAL STEEL ITEMS PER AISC 360 AND 341, UNLESS SPECIFICALLY NOTED OTHERWISE. QUALITY CONTROL (QC) TO BE PROVIDED BY THE FABRICATOR, ERECTOR OR OTHER RESPONSIBLE CONTRACTOR AS APPLICABLE. CONTRACTOR AND SPECIAL INSPECTOR TO DOCUMENT QUALITY CONTROL AS REQUIRED
IN AISC 360 SECTION N3 AND AISC 341 SECTION J2.
6 INSPECTION TYPES:
CONTINUOUS: THE FULL-TIME OBSERVATION OF WORK REQUIRING SPECIAL INSPECTION BY AN APPROVED SPECIAL
INSPECTOR WHO IS PRESENT IN THE AREA WHERE THE WORK IS BEING PERFORMED.
PERIODIC: THE PART-TIME OR INTERMITTENT OBSERVATION OF WORK REQUIRING SPECIAL INSPECTION BY AN APPROVED SPECIAL INSPECTOR WHO IS PRESENT IN THE AREA WHERE THE WORK HAS BEEN OR IS BEING PERFORMED
AND AT THE COMPLETION OF THE WORK.
OBSERVE: OBSERVE THESE FUNCTIONS ON A RANDOM, DAILY BASIS. OPERATIONS NEED NOT BE DELAYED PENDING
OBSERVATIONS
PERFORM: INSPECTIONS SHALL BE PERFORMED PRIOR TO THE FINAL ACCEPTANCE OF THE ITEM.
7 PERFORM INSPECTION PRIOR TO FINAL ACCEPTANCE OF THE ITEM FOR TEN WELDS TO BE MADE BY A GIVEN WELDER.
THE WELDER IS REQUIRED TO DEMONSTRATE THE UNDERSTANDING OF REQUIREMENTS AND POSSESSION OF SKILLS AND TOOLS TO VERIFY THESE ITEMS. ONCE THE INITIAL TEN WELDS HAVE BEEN ACCEPTED, THE WELDER SHALL REDUCE THE PERFORM DESIGNATION OF THIS TASK TO OBSERVE. SHOULD THE INSPECTOR DETERMINE THAT THE WELDER HAS STOPPED CONDUCTING THIS TASK, THE TASK SHALL BE RETURNED TO PERFORM UNTIL SUCH TIME AS THE INSPECTOR HAS RE-ESTABLISHED ADEQUATE ASSURANCE THAT THE WELDER WILL CONDUCT THE INSPECTION TASKS LISTED.
8 SPECIAL INSPECTION OF MECHANICAL POST INSTALLED ANCHORS SHALL BE IN STRICT CONFORMANCE WITH THE ICC REPORT AND MANUFACTURER'S INSTALLATION REQUIREMENTS. ANCHOR INSTALLERS SHALL BE QUALIFIED AS REQUIRED BY JURISDICTION REQUIREMENTS. INSPECTION REPORTS SHALL IDENTIFY NAMES OF INSTALLERS. SPECIAL INSPECTOR SHALL PROVIDE DOCUMENTATION AT THE END OF ANCHOR INSTALLATIONS STATING THAT THE ANCHORS
WERE INSPECTED PER APPROVED ANCHOR EVALUATION REPORT.
9 TESTING ABBREVIATIONS:
NDT - NON-DESTRUCTIVE TESTING
C.J.P. - COMPLETE JOINT PENETRATION
MT - MAGNETIC PARTICLE TESTING
RBS - REDUCED BEAM SECTION
10 DOCUMENT (D): INDICATES CONTRACTOR AND SPECIAL INSPECTOR TO PROVIDE DOCUMENTATION IN ACCORDANCE WITH
AISC 341.
CONTRACTOR RESPONSIBILITY:
EACH CONTRACTOR RESPONSIBLE FOR THE CONSTRUCTION OF THE MAIN WIND OR SEISMIC FORCE-RESISTING SYSTEM, DESIGNATED SEISMIC SYSTEM OR A WIND OR SEISMIC RESISTING COMPONENT LISTED THE TABLES SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON THE SYSTEM OR COMPONENT. THE CONTRACTOR'S STATEMENT OF RESPONSIBILITY SHALL CONTAIN THE
FOLLOWING:
ACKNOWLEDGEMENT OF AWARENESS OF THE SPECIAL REQUIREMENTS CONTAINED IN THE STATEMENT OF SPECIAL
INSPECTIONS.
1. ACKNOWLEDGEMENT THAT CONTROL WILL BE EXERCISED TO OBTAIN CONFORMANCE WITH THE CONSTRUCTION
DOCUMENTS APPROVED BY THE BUILDING OFFICIAL.
2. PROCEDURES FOR EXERCISING CONTROL WITHIN THE CONTRACTOR'S ORGANIZATION, THE METHOD AND FREQUENCY
OF REPORTING AND DISTRIBUTION OF THE REPORTS.
3. IDENTIFICATION AND QUALIFICATIONS OF THE PERSON(S) EXERCISING SUCH CONTROL AND THEIR POSITION(S) IN THE
ORGANIZATION.
TESTING NOTES:
1. CASTELLATED BEAM POST TESTING REQUIREMENTS:
A. PROVIDE ULTRASONIC TESTING ON THE GREATER OF 20% OF ALL WELDS OR FOUR WEB POST WELDS AT EACH CASTELLATED BEAM. THIS SHALL INCLUDE THE FIRST WEB POST AT EACH END OF THE BEAM AS WELL AS A MINIMUM OF TWO ADDITIONAL WEB POST WELDS SELECTED AT RANDOM FROM THE INTERIOR OF EACH BEAM SPAN. ULTRASONIC TESTING SHALL BE DONE IN ACCORDANCE WITH AWS D1.1 CRITERIA AND SHALL BE EVALUATED AGAINST ACCEPTANCE
CRITERIA FOR STATICALLY LOADED STRUCTURES.
B. FREQUENCY OF ULTRASONIC TESTING MAY BE REDUCED TO TWO MINIMUM WEB POSTS AT EACH BEAM ONCE A MINIMUM OF TEN BEAMS HAVE BEEN TESTED WITHOUT REJECTABLE FLAWS. TESTS SHALL INCLUDE ONE OF THE END
WEB POSTS AND ONE POST SELECTED AT RANDOM ON EACH SUBSEQUENT BEAM.
C. WHERE REJECTABLE FLAWS ARE ENCOUNTERED, THEY SHALL BE EVALUATED BY THE CELLULAR BEAM DESIGNER FOR DETERMINATION OF ANY NECESSARY REPAIRS, SUBJECT TO REVIEW AND APPROVAL BY THE ENGINEER OF RECORD.
D. WHERE REJECTABLE FLAWS ARE DETECTED AND REPAIRS ARE REQUIRED PER ITEM (C.) ABOVE, 100% OF ALL WEB POST WELDS FOR THAT PARTICULAR BEAM SHALL BE TESTED AND SAMPLING FREQUENCY FOR SUBSEQUENT BEAMS SHALL REVERT TO THE REQUIREMENTS STATED IN ITEM (A.) UNTIL AN ACCEPTABLE PASS RATE CAN AGAIN BE
ESTABLISHED AS NOTED IN ITEM (B.)
STEEL - SPECIAL INSPECTIONS
SYSTEM OR MATERIAL
OSSC CODE
REFERENCE
CODE OR
STANDARD
REFERENCE
FREQUENCY / INSPECTION
REMARKS
CONTINUOUS/
PERFORM
PERIODIC/
OBSERVE
STEEL FABRICATION
MATERIAL VERIFICATION OF WELD FILLER METALS
1705.2.1.1
TABLE
1705.2-5
AISC 360 A3.5
AISC 360 N3.2
APPLICABLE AWS
A5 DOCUMENTS
X MANUFACTURER'S CERTIFIED TEST REPORTS
STRUCTURAL STEEL WELDING
VERIFYING USE OF PROPER WPS'S
1705.2.1
AWS D1.1
AISC 360 N3.2
RETAIN A RECORD OF WELDING PROCEDURE
SPECIFICATIONS
VERIFYING WELDER QUALIFICATIONS AWS D1.1 X RETAIN A RECORD OF QUALIFICATION CARDS
SINGLE PASS FILLET WELDS LESS THAN OR EQUAL TO 5/16" X
VERIFICATION OF JOINT & CONNECTION DETAILS INCLUDING
MEMBER AND COMPONENT LOCATIONS, BRACING, AND
STIFFENERS
TABLE
1705.2-7
AWS D1.1 X
STRUCTURAL NOTES
GENERAL NOTES
THESE CONTRACT DOCUMENTS COMPRISED OF PLANS, SPECIFICATIONS, ENGINEERING AND DESIGN WORK ARE INTENDED SOLELY FOR THE PROJECT SPECIFIED HEREIN. MILLER CONSULTING ENGINEERS (MCE) DISCLAIMS ALL LIABILITY IF THESE PLANS AND SPECIFICATIONS OR THE DESIGN, ADVICE AND INSTRUCTIONS ATTENDANT THERETO ARE USED ON ANY PROJECT OR AT ANY LOCATION OTHER THAN THE PROJECT AND LOCATION
SPECIFIED HEREIN.
THE CONTRACT DOCUMENTS REPRESENT THE FINISHED STRUCTURE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONFORMANCE TO ALL SAFETY REGULATIONS DURING CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE
ALL METHODS, DIRECTION AND RELATED EQUIPMENT NECESSARY TO PERFORM THE WORK.
SHOULD ANY QUESTION ARISE REGARDING THE CONTRACT DOCUMENTS OR SITE CONDITIONS, THE CONTRACTOR SHALL REQUEST INTERPRETATION AND CLARIFICATION FROM THE ENGINEER BEFORE BEGINNING THE PROJECT.
THE ABSENCE OF SUCH REQUEST SHALL SIGNIFY THAT THE CONTRACTOR HAS REVIEWED AND FAMILIARIZED
THEMSELVES AND HAS COMPLETE COMPREHENSION OF ALL ASPECTS OF THE PROJECT.
THE CONTRACTOR IS RESPONSIBLE FOR VERIFICATION AND CORRELATION OF ALL ITEMS AND WORK NECESSARY FOR COMPLETION OF THE PROJECT AS INDICATED BY THE CONTRACT DOCUMENTS. THE CONTRACT DOCUMENTS ARE STRUCTURAL ONLY AND DO NOT NECESSARILYINDICATE ALL NON-STRUCTURAL PORTIONS OF THE PROJECT INCLUDING, BUT NOT LIMITED TO, PLUMBING, FIRE SUPPRESSION, ELECTRICAL, MECHANICAL, LAND USE, SITE PLANNING, EROSION CONTROL FLASHING AND WATER-PROOFING. ALL NON-STRUCTURAL PORTIONS OF WORK, AND STRUCTURAL WORK NOTED AS DELEGATED DESIGN IN THE SUBMITTAL SCHEDULE, ARE BEYOND THE SCOPE
OF THESE DOCUMENTS AND ARE PROVIDED BY OTHERS.
ANY MATERIAL NOT AS SPECIFIED IN THE CONTRACT DOCUMENTS OR IMPROPER MATERIAL INSTALLATION OR WORKMANSHIP SHALL BE REMOVED AND REPLACED WITH SPECIFIED MATERIAL IN A WORKMANLIKE MANNER AT THE CONTRACTOR'S EXPENSE. IT IS THE CONTRACTOR’S RESPONSIBILITY TO PROTECT ALL MATERIALS FROM
DAMAGE THROUGHOUT THE COURSE OF CONSTRUCTION.
ALL MANUFACTURED PRODUCTS SPECIFIED SHALL BE USED UNLESS AN ALTERNATE IS SUBMITTED AND APPROVED BY THE SEOR. MANUFACTURED PRODUCTS REQUIRING A BUILDING CODE EVALUATION REPORT SHALL HAVE A CURRENT REPORT DEMONSTRATING CONFORMANCE WITH THE APPLICABLE BUILDING CODE, VALID AT
THE TIME OF PRODUCT INSTALLATION.
TEMPORARY MEASURES/SHORING
THE CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING ALL INSTANCES WHERE TEMPORARY MEASURES/SHORING ARE REQUIRED, AND SHALL AT THEIR OWN EXPENSE, ENGAGE PROPERLY QUALIFIED PERSONS TO DETERMINE WHERE AND HOW TEMPORARY MEASURES/SHORING ARE REQUIRED. TEMPORARY MEASURES/SHORING SHALL:
o PROTECT PERSONNEL AND THE PUBLIC.
o PREVENT SETTLEMENT AND/OR DAMAGE TO THE BUILDING AND/OR EXISTING FACILITIES o PROTECT STREETS, WALKWAYS, UTILITIES, AND IMPROVEMENTS.
o PROTECT ALL EXCAVATIONS AGAINST LOSS OF GROUND OR CAVING OF EMBANKMENTS DURING
CONSTRUCTION.
BUILDING CODE
ALL PHASES OF THE WORK SHALL CONFORM TO THE 2025 OREGON STRUCTURAL SPECIALTY CODE (OSSC), BASED ON THE 2024 INTERNATIONAL BUILDING CODE (IBC), INCLUDING ALL REFERENCE STANDARDS, UNLESS NOTED
OTHERWISE.
SPECIAL INSPECTION/TESTING
SPECIAL INSPECTION AND/OR TESTING IS REQUIRED IN ACCORDANCE WITH BUILDING CODE SECTION 1704. IT IS THE OWNER'S RESPONSIBILITY TO PROVIDE SPECIAL INSPECTION AND TESTING BY A QUALIFIED THIRD PARTY, SUCH AS A TESTING AGENCY REVIEWED BY THE ENGINEER AND APPROVED BY THE BUILDING OFFICIAL. THE CONTRACTOR SHALL PROVIDE SUFFICIENT NOTICE TO ALLOW SCHEDULING OF SPECIAL INSPECTION.
SPECIAL INSPECTIONS SHALL CONFORM TO SECTION 1705 OF THE BUILDING CODE, CONTRACT DOCUMENTS AND SUBMITTALS. THE SPECIAL INSPECTOR SHALL OBSERVE THE INDICATED WORK FOR COMPLIANCE WITH THE CONSTRUCTION DOCUMENTS. ALL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTOR FOR CORRECTION AND NOTED IN THE INSPECTION REPORTS. FOR PROJECT REQUIREMENTS REFER TO THE
SPECIAL INSPECTION TABLES WITHIN THE CONTRACT DOCUMENTS.
SHOP DRAWINGS/SUBMITTALS
SUBMITTALS AND SHOP DRAWINGS FOR SPECIFIC PRODUCTS GENERATED BY THE SUPPLIER SHALL BE SUBMITTED FOR THE ITEMS NOTED IN THE SUBMITTAL SCHEDULE. SHOP DRAWINGS SHALL BE TO SCALE AND SHOW COMPLETE DETAILS AND INSTRUCTIONS FOR FABRICATION AND ASSEMBLY. SHOP DRAWINGS SHALL
INDICATE ERECTION AND TEMPORARY BRACING INFORMATION FOR CONTRACTOR’S USE.
THE DESIGN OF ITEMS NOTED IN THE SUBMITTAL SCHEDULE AS DELEGATED DESIGN SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. DOCUMENTS FOR THE DESIGN AND FABRICATION OF DELEGATED DESIGN ITEMS (INCLUDING STRUCTURAL CALCULATIONS AND DRAWINGS) SHALL BEAR THE SEAL AND SIGNATURE OF A
LICENSED ENGINEER REGISTERED IN THE STATE THAT THE PROJECT IS BEING CONSTRUCTED.
DEFERRED SUBMITAL ITEMS NOTED IN THE SUBMITTAL SCHEDULE ARE PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE TIME OF PERMIT APPLICATION AND ARE REQUIRED TO BE SUBMITTED TO THE BUILDING
OFFICIAL.
THE CONTRACTOR SHALL REVIEW AND MODIFY ALL SUBMITTALS AS REQUIRED FOR CONFORMANCE WITH THE CONTRACT DOCUMENTS AND SIGN AND DATE ALL SETS OF THE SUBMITTAL DOCUMENTS PRIOR TO SUBMITTAL TO THE ENGINEER. THE CONTRACTOR SHALL SCHEDULE SUBMITTALS TO ALLOW SUFFICIENT TIME FOR REVIEW AND POSSIBLE RE-SUBMITTAL. WHERE RE-SUBMITTALS ARE REQUIRED, CHANGES FROM THE PREVIOUS SUBMITTAL
SHALL BE CLEARLY INDICATED WITH REVISION CLOUDS OR SIMILAR.
SUBMITTAL SCHEDULE
ITEM SUBMITTAL
SHOP
DRAWINGS
DELEGATED
DESIGN
DEFERRED
SUBMITTAL
STRUCTURAL STEEL X X
STEEL WELDING PROCEDURES X
STEEL FASTENERS X
STRUCTURAL DESIGN CRITERIA
LIVE LOAD REDUCTION FOR BEAMS AND COLUMNS WAS NOT USED. DESIGN FOR MECHANICAL LOADS INCLUDES ONLY THOSE INDICATED ON STRUCTURAL DRAWINGS. THE FOLLOWING ARE THE DESIGN REQUIREMENTS:
STRUCTURAL DESIGN CRITERIA
RISK CATEGORY II
WIND DESIGN DATA
BASIC DESIGN WIND SPEED (3 SEC GUST) V = 96 MPH
EXPOSURE B
FORCE COEFFICIENT (FIGURES 29.4-1 — 29.4-4) Cf = 0.7
SEISMIC DESIGN DATA
IMPORTANCE FACTOR Ie = 1.0
SPECTRAL RESPONSE ACCELERATIONS SS = 0.930, S1 = 0.380
SITE CLASS DEFAULT
SPECTRAL RESPONSE COEFFICIENTS SDS = 0.793, SD1 = 0.540
NONSTRUCTURAL COMPONENTS
IMPORTANCE FACTOR IP = 1.0
SEISMIC RESPONSE COEFFICIENT FP = 0.488
STRUCTURE DUCTILITY REDUCTION FACTOR Rm = 1.3
COMPONENT RESONANCE DUCTILITY FACTOR CAR = 1.0
COMPONENT STRENGTH FACTOR Rpo = 1.50
ANCHORAGE OVERSTRENGTH FACTOR Ωop = 2.00
ANALYSIS PROCEDURE USED
ASCE/SEI 7-22 CHAPTER 13 SEISMIC DESIGN
FORCES FOR NONSTRUCTURAL COMPONENTS
STRUCTURAL STEEL
DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO THE SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS (AISC 360). QUALITY ASSURANCE (QA) IS REQUIRED FOR STRUCTURAL STEEL ITEMS PER AISC 360 AND 341 UNLESS SPECIFICALLY NOTED OTHERWISE. QUALITY CONTROL (QC) TO BE PROVIDED BY THE FABRICATOR, ERECTOR OR OTHER RESPONSIBLE CONTRACTOR AS APPLICABLE. CONTRACTOR AND SPECIAL INSPECTOR TO DOCUMENT QUALITY CONTROL AS REQUIRED IN AISC 360 SECTION N3 AND AISC 341
SECTION J2.
STRUCTURAL STEEL MATERIAL STANDARDS
SHAPE ASTM SPECIFICATION YIELD STRESS
W-SECTIONS A992 50 KSI
PIPE A53, GRADE B, TYPE E OR S 35 KSI
ALL OTHER SECTIONS AND PL A36 36 KSI
ALL STRUCTURAL STEEL SHALL HAVE ONE SHOP COAT OF PRIMER, EXCEPT SURFACES TO BE EMBEDDED IN CONCRETE OR MASONRY OR STEEL TO BE GALVANIZED. EMBEDDED SURFACES SHALL BE FREE OF CONTAMINANTS. ALL EXPOSED STRUCTURAL STEEL AND FASTENINGS TO HAVE ONE FINISH COAT OF RUST
INHIBITING PAINT, COLOR BY OWNER.
GALVANIZED COATINGS
ALL ZINC (GALVANIZED) COATINGS ON IRON AND STEEL PRODUCTS SHALL CONFORM TO ASTM A123. REPAIRS OF
GALVANIZED COATINGS ARE TO CONFORM TO ASTM A780.
STRUCTURAL STEEL BOLTING
ALL BOLTS IN STEEL TO STEEL CONNECTIONS SHALL BE ASTM F3125 GRADE A325 WITH MATCHING NUTS, UNLESS NOTED OTHERWISE. NUTS SHALL BE TIGHTENED TO A SNUG TIGHT CONDITION, UNLESS CONNECTION IS NOTED
AS SLIP-CRITICAL OR PRETENSIONED.
o SNUG TIGHT CONDITION SHALL BE PER RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS (RCSC)
SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH-STRENGTH BOLTS, SECTION 8.1.
o SLIP-CRITICAL AND PRETENSIONED CONNECTIONS, INSTALLATION OF FASTENERS SHALL BE PER RCSC
SECTION 8.2.
FASTENER COATINGS
HOT DIP GALVANIZED COATINGS ON ASTM F3125 GRADE A325 FASTENER ASSEMBLIES SHALL CONFORM TO ASTM A153. SURFACE PREPARATION OF GALVANIZED STEEL TO RECEIVE A FINISH COAT OF PAINT SHALL CONFORM TO
ASTM D6386.
STRUCTURAL STEEL WELDING
ALL WELDING SHALL CONFORM TO AMERICAN WELDING SOCIETY (AWS) D1.1 USING E70XX ELECTRODES. WELDING SHALL BE PERFORMED BY WELDERS CERTIFIED BY AWS FOR THE WELD TYPES SPECIFIED. WELD LENGTHS SHOWN ARE EFFECTIVE AS SPECIFIED PER THE SPECIFICATIONS OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC). WHERE WELD LENGTHS ARE NOT SHOWN, THE WELD SHALL BE FULL LENGTH OF MEMBERS BEING JOINED. FIELD WELDING SYMBOLS HAVE NOT NECESSARILY BEEN INDICATED ON THE DRAWINGS. WHERE SHOWN, PROPER FIELD WELDING PER AWS D1.1 SHALL BE USED. WHERE NO FIELD WELDING SYMBOLS ARE SHOWN, IT IS THE CONTRACTOR’S RESPONSIBILITY TO COORDINATE THE USE OF SHOP AND FIELD
WELDS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE JOINT PREPARATION AND WELDING PROCEDURES THAT INCLUDE, BUT ARE NOT LIMITED TO: REQUIRED ROOT OPENINGS, ROOT FACE DIMENSIONS, GROOVE ANGLES, BACKING BARS, COPES, SURFACE ROUGHNESS VALUES AND TAPERS AND TRANSITIONS OF UNEQUAL PARTS.
ALL WELDS SHALL RECEIVE THE SAME FINISH COATING AS THE MEMBER BEING WELDED. ANY COATINGS ON THE
STRUCTURAL AFFECTED BY WELDING SHALL BE REPAIRED AS REQUIRED.
ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL CONFORM TO THE FOLLOWING MATERIAL STANDARDS:
SHEET
9600 SW Oak St | Suite 400 Portland, OR | 97223
503.246.1250 | miller-se.com
MCE PROJ #:
SHEET CONTENT
ISSUE DATE:
CHECKED BY:
© MILLER CONSULTING ENGINEERS
CONSULTING
MILLER
ENGINEERS
DESIGNED BY:
ISSUANCE:
S0.02
OPERATIONS
FACILITY ANTENNA
INSTALLATION
OREGON MILITARY
DEPARTMENT
1921 TURNER RD SE
SALEM, OREGON
STRUCTURAL NOTES &
SPECIAL INSPECTION
260572
09.23.2026
PERMIT SET
REV DESCRIPTION DATE
CCS
ERW
OREGON
J
A
N
U
A
R
Y
E
N
G
I N
E
E
R
51043
R
E
G
I
S
T
E
R
E
D
PR
O
F
E
S
S
I
O
N
A
L
E
R
A
T
S
O
N
S
T
R
U
C T
U
R
A
L
GENERAL SHEET NOTES:
G1. SEE AND SUBSEQUENT SHEETS FOR STRUCTURAL NOTES
AND SPECIAL INSPECTION REQUIREMENTS
G2. REFER TO ORIGINAL CONSTRUCTION DOCUMENTS FOR
DIMENSIONS NOT PROVIDED.
G3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION
S0.02
S3.01
(3) (N) ANTENNA MOUNTS PER /1 S3.01
SHEET
9600 SW Oak St | Suite 400 Portland, OR | 97223
503.246.1250 | miller-se.com
MCE PROJ #:
SHEET CONTENT
ISSUE DATE:
CHECKED BY:
© MILLER CONSULTING ENGINEERS
CONSULTING
MILLER
ENGINEERS
DESIGNED BY:
ISSUANCE:
S1.01
OPERATIONS
FACILITY ANTENNA
INSTALLATION
OREGON MILITARY
DEPARTMENT
1921 TURNER RD SE
SALEM, OREGON
BUILDING PLAN
260572
09.23.2026
PERMIT SET
-N O R
TH
REV DESCRIPTION DATE
S1.01 | 1/16" = 1'-0"1 BUILDING PLAN
CCS
ERW
OREGON
J
A
N
U
A
R
Y
E
N
G
I N
E
E
R
51043
R
E
G
I
S
T
E
R
E
D
PR
O
F
E
S
S
I
O
N
A
L
E
R
A
T
S
O
N
S
T
R
U
C T
U
R
A
L
GENERAL SHEET NOTES:
G1. SEE AND SUBSEQUENT SHEETS FOR STRUCTURAL NOTES
AND SPECIAL INSPECTION REQUIREMENTS
G2. REFER TO ORIGINAL CONSTRUCTION DOCUMENTS FOR
DIMENSIONS NOT PROVIDED.
G3. FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION
S0.02
S6.01
F
R O
M T
O P
O F
R O
O F
F
R O
M T
O P
O F
R O
O F
F
R O
M T
O P
O F
R O
O F
TYP
(N) ANTENNA MOUNT PER , TYP/1 S6.01
S6.01
TYP
SHEET
9600 SW Oak St | Suite 400 Portland, OR | 97223
503.246.1250 | miller-se.com
MCE PROJ #:
SHEET CONTENT
ISSUE DATE:
CHECKED BY:
© MILLER CONSULTING ENGINEERS
CONSULTING
MILLER
ENGINEERS
DESIGNED BY:
ISSUANCE:
S3.01
OPERATIONS
FACILITY ANTENNA
INSTALLATION
OREGON MILITARY
DEPARTMENT
1921 TURNER RD SE
SALEM, OREGON
ELEVATION
260572
09.23.2026
PERMIT SET
REV DESCRIPTION DATE
S3.01 | 1/8" = 1'-0"1 PARTIAL ELEVATION
CCS
ERW
OREGON
J
A
N
U
A
R
Y
E
N
G
I N
E
E
R
51043
R
E
G
I
S
T
E
R
E
D
PR
O
F
E
S
S
I
O
N
A
L
E
R
A
T
S
O
N
S
T
R
U
C T
U
R
A
L
1/4
1/4
P E
R E
L E
V A
T
IO
N
S6.01
C6x13 ACROSS (2) BAYS TO
BRACE ANTENNA MOUNTS.
3" DIA SCH40 PIPE CENTERED ON BOT PLATE
(E) W8x10 OUTRIGGER
(E) W8x10 OUTRIGGER CONNECTION
TO (E) BUILDING TO REMAIN
PL1/4 x 6 x 0'-6"
PL1/4 x 3 7/16 x 1'-11 3/4"
SHIM PLATE SAME THICKNESS
AS BOT FLANGE OF (E) W8x10
(4) 3/8" THROUGH BOLTS BY ANTENNA MANUF TO
ALIGN WITH MANUF BASE ANCHOR BOLT LAYOUT
ANTENNA & BASE DESIGNED BY OTHERS
.2
.2
P
E R
A N
T E
N N
A M
F G
V E
R
IF
Y I N
F
IE
L D
/8
1/4
TYP
1/4
PL 3/4 x 6 x 0'-6"
1/4" PLATE EA SIDE OF WEB
PER DETAIL /3 S6.01
PL1/4 x 1 5/8 x 0'-6 1/2" STIFFENERS EA SIDE OF W8x10
1/41/4
/1
4 1/16"
/2
9 1/2"
/2
1'-1 11/16"
VERIFY
V E R
IF
Y
2 7/8"
/8
/4
/8
1 1/2" 1 1/2"
A
A
SECTION A-A
1/4
TYP
1/4
TYP
L3 1/2x2 1/2x1/2 x 0'-5" LONG EA SIDE OF
PLATES TO BE BOLTED TO CHANNEL BRACE
SPLICE LOCATION
AT CENTER BAY
CHANNEL TO EXTEND PAST
OUTRIGGER AT OUTSIDE BAYS
SHEET
9600 SW Oak St | Suite 400 Portland, OR | 97223
503.246.1250 | miller-se.com
MCE PROJ #:
SHEET CONTENT
ISSUE DATE:
CHECKED BY:
© MILLER CONSULTING ENGINEERS
CONSULTING
MILLER
ENGINEERS
DESIGNED BY:
ISSUANCE:
S6.01
OPERATIONS
FACILITY ANTENNA
INSTALLATION
OREGON MILITARY
DEPARTMENT
1921 TURNER RD SE
SALEM, OREGON
STEEL DETAILS
260572
09.23.2026
PERMIT SET
REV DESCRIPTION DATE
S6.01 | 1 1/2" = 1'-0"1 ANTENNA MOUNT
S6.01 | 6" = 1'-0"2 ANTENNA MOUNT SECTION
S6.01 | 6" = 1'-0"3 CUSTOM SIDE PLATES
CCS
ERW
OREGON
J
A
N
U
A
R
Y
E
N
G
I N
E
E
R
51043
R
E
G
I
S
T
E
R
E
D
PR
O
F
E
S
S
I
O
N
A
L
E
R
A
T
S
O
N
S
T
R
U
C T
U
R
A
L
| Sheets |
| S0.01 - COVER SHEET |
| S0.02 - STRUCTURAL NOTES & SPECIAL INSPECTION |
| S1.01 - BUILDING PLAN |
| S3.01 - ELEVATION |
| S6.01 - STEEL DETAILS |
| 2026-09-23T10:04:03-0700 | |
| Eric Watson |
| 2026-09-23T10:04:16-0700 | |
| Eric Watson |
| 2026-09-23T10:04:34-0700 | |
| Eric Watson |
| 2026-09-23T10:04:51-0700 | |
| Eric Watson |
| 2026-09-23T10:05:05-0700 | |
| Eric Watson |