20260423_City_Hall_Wind_Protection_Plan_Set.pdf
PDF 20 MB Posted
- Attached to
- City Hall Wind Mitigation (Re-bid)
- Solicitation number
- 26-014
- Issued by
- Santa Rosa County, Florida
About this file
Summary
This is a plan set document for the Dania Beach City Hall Wind Protection project located at 100 W. Dania Beach Boulevard, Dania Beach, Florida 33004. The project is managed by the City of Dania Beach with professional engineering services provided by Calvin, Giordano Associates, Inc., Lakdas/Yohalem Engineering, Inc., and associated licensed professional engineers. The scope of work encompasses installation of a new 400-kilowatt diesel generator with an 668-gallon belly tank to replace an existing 350-kilowatt generator, installation of new automatic transfer switches (1200-ampere ATS#1 and 600-ampere ATS#2), replacement of associated electrical feeders and conduits, wind protection modifications to the building including new roofing membrane work at window sills on the north and east elevations, structural reinforcements including new concrete slab work and masonry walls in the generator compound area, base plate and column corrosion repairs, and civil site work including stormwater management and landscaping restoration. The design standards specify wind pressures calculated for 180-mile-per-hour winds in Exposure Category C per ASCE 7-22 and FBC 2023, 8th Edition. The plan set consists of cover sheets, signature sheets, site plans, electrical notes and diagrams, structural plans with wind pressure details and elevation drawings, and generator enclosure plans with construction details. Bid documents are marked "Not for Construction," indicating they represent preliminary design documents for bidding purposes. No specific response date, bid due date, site visit requirements, or pre-bid conference information is provided in the document itself.
The document does not contain pricing terms, set-aside information, incumbent contractor data, or funding sources. The project requires coordination between multiple trades including electrical, structural, and civil contractors. Notable requirements include contractor responsibility for field verification of existing utility locations prior to construction, temporary generator provisions during installation of the permanent emergency power system, coordination with the manufacturer for generator delivery to the site, provision of a temporary 200-kilowatt generator during construction, and development of a traffic control and maintenance of traffic plan for city approval. The contractor must comply with FBC 2023, NEC 2020 codes, state and local building codes, and interface the generator system with the building fire alarm system per NFPA 70E and 72 standards. Contractor responsibilities also include shop drawing submissions, selective coordination study for overcurrent protection, operation and maintenance instruction manuals, system start-up and testing, and one-year guarantees against defective workmanship and materials.
View the file
Other files
Show all 47
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PR
OJ
EC
T
No : 2
DANIA BEACH, FLORIDA
NOTES:
LEGAL DESCRIPTION:
JENNA MARTINETTI, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 69035.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JENNA MARTINETTI, P.E. ON THE
DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
N
S
W E
BENCHMARK:
PROJECT
LOCATION
DANIA BEACH CITY HALL WIND
PROTECTION
Scale: 1" = 300'
LOCATION MAP
CITY LOGO HERE
NUMBER
PERMITCGA
INITIALSSUBMITTED
DATEPERMITTING AGENCIES DATE
APPROVED
CURRENT REV No.: ---- - ----
SHEET:
DATE:NONO DATE REVISION BY REVISIONDATE BY 04/21/2026
G0
R
KNOW WHAT'S BELOW
AL W A Y S C A L L 8 1 1
B E F O R E Y O U D I G
It's fast. It's free. It's the law.
www.callsunshine.com
BID SET
NOT FOR CONSTRUCTION
CITY OFFICIALSCITY OFFICIALS
MAYOR: JOYCE L. DAVIS
VICE-MAYOR: MARCO A. SALVINO, SR.
COMMISSIONERS: LORI LEWELLEN
LUIS RIMOLI
ARCHIBALD J. RYAN IV
CITY MANAGER: ANA M. GARCIA
S.
F
ED
ER
AL
H
W Y
DANIA BEACH BLVD.
N W
ST
A
VE
N W rd
A
VE
HILL ST.
STIRLING ROAD
Sheet List Table Sheet Number Sheet Title
G0 COVER
G1 SIGNATURE SHEET
G2 LEGEND, ABBREVIATIONS AND GENERAL NOTES
C1 SITE PLAN
C2 DETAILS
E1 ELECTRICAL NOTES
E2 ELECTRICAL SITE PLAN
E3 ELECTRICAL RISERS
E4 PARTIAL ELECTRICAL PLANS
E5 GENERATOR DETAILS
E6 GENERATOR DETAILS
CV INDEX SHEET
S-1 PLAN VIEW WIND PRESSURES
S-2 NORTH, SOUTH, EAST, WEST ELEVATIONS
S-3 PARTIAL PLAN AND DETAILS
S-3.1 PARTIAL PLAN AND DETAILS
S-3.2 PARTIAL PLAN AND DETAILS
S-4 PARTIAL PLAN AND DETAILS
S-5 GENERATOR ENCLOSURE PLAN AND DETAILS
MULTICORELINK:G1 SIGNATURE SHEET-G1 SIGNATURE SHEET
MULTICORELINK:G1 SIGNATURE SHEET-G1 SIGNATURE SHEET
ELECTRICAL PLANS
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR THE
FOLLOWING SHEETS IN ACCORDANCE WITH THE RULE 61G15-23.004, F.A.C.
JORGE R. CERVANTES, STATE OF FLORIDA,
PROFESSIONAL ENGINEER, LICENSE NO. 45832.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED
BY JORGE R. CERVANTES, P.E. ON THE DATE
INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
J o rge R. CervantesLICENSE
NO. 45832
PRO
FESSIONA L ENGIN
EE
R
FLO R IDA
STATE OF
CALVIN, GIORDANO ASSOCIATES, INC.
1800 ELLER DRIVE, SUITE 600
FORT LAUDERDALE, FLORIDA 33316
954-921-7781
SIGNATURE SHEET
DANIA BEACH CITY HALL WIND PROTECTION
DANIA BEACH, FLORIDA
NONO DATE REVISION BY REVISIONDATE BY
SCALE
PROJECT No
SHEET
DATE:
R
KNOW WHAT'S BELOW
A L W A Y S C A L L 8 1 1 B E F O R E Y O U D I G
It's fast. It's free. It's the law.
www.callsunshine.com
G1
CIVIL PLANS
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR THE
FOLLOWING SHEETS IN ACCORDANCE WITH THE RULE 61G15-23.004, F.A.C.
LAKDAS/YOHALEM ENGINEERING, INC.
2211 NE 54th ST.
FORT LAUDERDALE, FLORIDA 33308
954-771-0630
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR THE
FOLLOWING SHEETS IN ACCORDANCE WITH THE RULE 61G15-23.004, F.A.C.
LAKDAS NANAYAKKARA, STATE OF FLORIDA,
PROFESSIONAL ENGINEER, LICENSE NO. 037590.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY LAKDAS NANAYAKKARA, P.E. ON THE
DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
CALVIN, GIORDANO ASSOCIATES, INC.
1800 ELLER DRIVE, SUITE 600
FORT LAUDERDALE, FLORIDA 33316
954-921-7781
STRUCTURAL PLANS
JENNA MARTINETTI, STATE OF FLORIDA,
PROFESSIONAL ENGINEER, LICENSE NO. 69305.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED
BY JENNA MARTINETTI, P.E. ON THE DATE INDICATED
HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC
COPIES.
J e nna MartinettiLICENSE
NO. 69305
PRO
FESSIONA L ENGIN
EE
R
FLO R IDA
STATE OF
LICENSE
Sheet List Table
Sheet Number Sheet Title
G0 COVER
G2 LEGEND, ABBREVIATIONS AND GENERAL NOTES
C1 SITE PLAN
C2 DETAILS
Sheet List Table
Sheet Number Sheet Title
CV INDEX SHEET
S-1 PLAN VIEW WIND PRESSURES
S-2 NORTH, SOUTH, EAST, WEST ELEVATIONS
S-3 PARTIAL PLAN AND DETAILS
S-3.1 PARTIAL PLAN AND DETAILS
S-3.2 PARTIAL PLAN AND DETAILS
S-4 PARTIAL PLAN AND DETAILS
S-5 GENERATOR ENCLOSURE PLAN AND DETAILS
Sheet List Table
Sheet Number Sheet Title
E1 ELECTRICAL NOTES
E2 ELECTRICAL SITE PLAN
E3 ELECTRICAL RISERS
E4 PARTIAL ELECTRICAL PLANS
E5 GENERATOR DETAILS
E6 GENERATOR DETAILS
MULTICORELINK:G0 COVER-G0 COVER
MULTICORELINK:G0 COVER-G0 COVER
ABBREVIATION LEGEND
FIRE HYDRANT
GROUND/LANDSCAPING LIGHTING
FIRE DEPARTMENT CONNECTION
M WATER METER
SINGLE WATER SERVICE
DOUBLE WATER SERVICE
BACKFLOW PREVENTER
BLOWOFF
REDUCER
GATE VALVE
90°, 45°, 22.5° & 11.25° BENDS
CATCH BASIN
MANHOLE
CLEANOUT
DRAINAGE FLOW
SPOT GRADE
STORM YARD DRAIN
P5 STORM INLET
P6 STORM INLET
0.00
EXFILTRATION TRENCH
PAVEMENT RESTORATION
CONCRETE
LANDSCAPING RESTORATION (HEDGE, SOD, MULCH)
DOUBLE DETECTOR CHECK VALVE
FPL MANHOLE
CONCRETE UTILITY POLE
GUY ANCHOR
COMMUNICATION MH
COMMUNICATION RISER
CABLE TV MANHOLE
ELEC. HANDHOLE
FPL TRANSFORMER
GAS METER
LIGHT POLE
TRAFFIC CONTROL BOX
WOOD POWER POLE
CLEANOUT
CABLE TV RISER
FPL
C
EHH
E
GAS
CONCRETE LIGHT POLE
CLP
WPP
SECTION LINE
R/W LINE
CENTERLINE
EXISTING CHAIN LINK FENCE
GUARDRAIL
EXISTING SANITARY SEWER
EXISTING NATURAL GAS
EXISTING IRRIGATION
EXISTING OXYGEN
EXISTING UNDERGROUND POWER
EXISTING STORM SEWER
EXISTING WATER MAIN
TO BE DEMOLISHED
EXISTING FORCE MAIN
EXISTING FIRE MAIN
EXISTING CONDENSATION
LOT LINE
EXISTING BURIED FIBER OPTIC
EXISTING UNDERGROUND COMCAST
EXISTING CHILLER
EXISTING AT&T UNDERGROUND
EXISTING FUEL LINE
EXISTING OVERHEAD ELECTRIC
EXISTING UNDERGROUND ELECTRIC
EXISTING UNKNOWN UTILITY
PROPOSED CHAIN LINK FENCE
EXISTING WOOD FENCE
EXISTING PICKET FENCE
LINE TYPE LEGEND
HATCHING LEGEND
PROPOSED SYMBOL LEGEND
SPOT ELEVATION (FT)
x 8.
TEE
CROSS
AIR RELEASE VALVE
VERTICAL BENDS
PLUG
BLOWOFF
1 CONFLICT ID
SANITARY FLOW DIRECTION
CLEAN OUT
SINGLE SANITARY LATERAL
DOUBLE SANITARY LATERAL
HEADWALL
MITERED END - RCP
MITERED END - HDPE
SLOTTED DRAIN
SYNTHETIC BALES
ROCK BAGS W/ SYNTHETIC BALES
SILT BARRIER FENCE
TURBIDITY BARRIER
B.S.P. No. BACTERIOLOGICAL SAMPLE POINT
GATE VALVE
IRR
WATER VALVE
SEWER VALVE
GAS VALVE
GV
SV
WV
FIRE HYDRANT
REDUCER
IRRIGATION VALVE
SANITARY MANHOLE
FIRE DEPARTMENT
CURB INLET
CONCRETE SIGNAL POLE
CSP
M
SIGN
WATER METER
NVAL
EXISTING SYMBOL LEGEND
SIGN
ARV AIR RELEASE VALVE
BE BURIED ELECTRIC
BFP BACKFLOW PREVENTER
BFV BUTTERFLY VAVLE
BM BENCHMARK
BOP BOTTOM OF PIPE
BSP BACTERIOLOGICAL SAMPLING POINT
CAP CORRUGATED ALUMINUM PIPE
CB CATCH BASIN
CI CURB INLET
CIP CAST IRON PIPE
CLF CHAIN LINK FENCE
CMP CORRUGATED METAL PIPE
CO CLEANOUT
CONC CONCRETE
DE DRAINAGE EASEMENT
DIP DUCTILE IRON PIPE
E EAST
EL ELEVATION
EOW EDGE OF WATER
EXIST EXISTING
EXFILT EXFILTRATION
FF EL FINISHED FLOOR ELEVATION
FH FIRE HYDRANT
FM FORCE MAIN
GALV GALVANIZED
GV GATE VALVE
HORZ HORIZONTAL
H.P. HIGH POINT
INV INVERT
JB JUNCTION BOX
LF LINEAR FEET
MAX MAXIMUM
ME MATCH EXISTING
MH MANHOLE
MIN MINIMUM
MJ MECHANICAL JOINT
N NORTH
NAVD NORTH AMERICAN VERTICAL DATUM
NGVD NATIONAL GEODETIC VERTICAL DATUM
NIC NOT INCLUDED
NTS NOT TO SCALE
OE OVERHEAD ELECTRIC
PCAP PERFORATED CORRUGATED ALUMINUM PIPE
PP POLYPROPYLENE
PRB POLLUTION RETARDANT BAFFLE
PROP PROPOSED
PSI POUNDS PER SQUARE INCH
PV PLUG VALVE
PVC POLYVINYL CHLORIDE
R RADIUS
RCP REINFORCED CONCRETE PIPE
RCW RECLAIMED WATER
RED REDUCER
R/W RIGHT-OF-WAY
S SOUTH
SAN SANITARY
SB SOIL BORING
STA STATION
TOB TOP OF BANK
TOP TOP OF PIPE
TYP TYPICAL
UE UTILITY EASEMENT
VERT VERTICAL
W WEST
WM WATER MAIN
HOSE BIBB
D
LIGHT POLE
S
ELECTRIC MANHOLE
EMH
PROPERTY LINE
CATCH BASIN
STORM MANHOLE
1" ASPHALT MILLING AND RESURFACING
GRAVEL RESTORATION
6" STEP
NONO DATE REVISION BY REVISIONDATE BY
SCALE
PROJECT No
SHEET
DATE:Fi le
N am e:
P:
\P ro je ct s\
\2
D an ia
B ea ch E ng in ee rin g Se rv ic es \2
7.
D an ia B ea ch
W in d Pr ot ec tio n
An d
Ba ck up P ow er
T o
C ity
H al l\c ad d Fi le s\
D ra w in gs \s he et
S et
\G
LE
G
EN
D
, A
BB
R
EV
IA
TI
O N
S
AN
D G
EN
ER
AL
N
O
TE
S.
dw g
P lo tte d by
M au ric io G om ez o n Th ur sd ay , A pr il
, 2
2:
:1
P M
JENNA MARTINETTI, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 69035.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JENNA MARTINETTI, P.E. ON THE
DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
R
KNOW WHAT'S BELOW
A L WA Y S C A L L 8 1 1
B E F O R E Y O U D I G
It's fast. It's free. It's the law.
www.callsunshine.com
04/21/2026 2259171
AS SHOWN G2LEGEND, ABBREVIATIONS AND
GENERAL NOTES
DANIA BEACH CITY HALL WIND PROTECTION
DANIA BEACH, FLORIDA
BID SET
NOT FOR CONSTRUCTION
C O
N C
R E
TE
S
ID
E
W A
LK
CONC.
CONC.
25.0'
.1
16.3'
A /C
A /C6'
C B
S W
A
LL
GATE
CONC.
CONCRETE SIDEWALK
BRICK DRIVE
BLDG. OVERHANG
11.21
9.48
SMN
10.
10.
11.6
10.
.76
10.
.63 10.79
10.
10.50
10.
10.49 10 .3
.32
10.24 10.
10.
.2
10.
3310.39
10.59
10.64 10 .62
10.98
.89
11.03
11.
11.
12.
12.
12.
11.
11.
11.
WV
.43
11.66
11.
10.
10.94
10.
10.
10.85
11.
11.
11.
10.6810.
10.
11.
11.
11.
11.
10.67
.41
10.
10.
11.
11.
10.
9.9
11.26 11 .38
11.
11.92
10.
6 10.
11.39
10.
10.
10.
11.69
11.68
11.6111.16 11.
0911.12
11.
11.
11.
0911.
1011.
11.
11.18
11.19
11.89 11.
11.94
11.40 11.
11.
11.20
11.32
.05
.1
11.
1311.06
11.
11.01 10 .9
10.93 10.90 10.85
10.
.85
10.77 10.
.74
10.
.7
10.
7110.
10.64
10.68
11.
D
E
EE
E
.3
10.
10.67
11.00 10.91
10.88 10.93
10.
.08
10.
10.
10.
11.
10.
11.0611 .03
12.40
11.
.29
11.
11.
14 11.28
11.
11.
11.
11.
11.
11.
11.
.00
CONC.
C O
N C
DU
MP
ST
ER
P A
D
CONCRETE SIDEWALK
CONC.
C
O N
C R
ET
E
CONCRETE
C O
N C
C U
R B
C O
N C
A/C'S
TRANSFORMER
PAD
M E
TA
L
S
TE
P S
C O
N C
R
ET
E G
EN
ER
AT
O
R P
A D
A/C'S
ASPHALT PARKING
A
S P
H A
LT
P
A R
K
IN
G
C O
N C
R
ET
E
SI
D
EW
AL
K
CONC
STEP
55.6'
27.4'
20.7'
26.5'
12.4'
.5
.8
.0
.0
' 72.7'
.4
12.3'
.1
42.1' 7.0'
.3
.3
55.1' .4
7.8'
.9
93.8'
.1
51.1'
.7
.5
13.8'
6.5'1.
3'
3.4' 20.7'
.1
' 4 .3
375.31'
3.
ORIGINAL BLOCK LINE
104°29'21"
ONE AND TWO STORY CBS BUILDING
FLOOR ELEVATION=12.40'(NAVD88)
SECOND FLOOR ELEVATION 24.45'
5/ 8"
F C
IR
L B
4' C
O N
C R
E
TE
W A
LK
4' C
O N
C R
E
TE
W A
LK
E D
G E
O F
P A
V E
M E
N T
E D
G E
O F
P A
V E
M E
N T
R
AM
P
WOOD
GATES
9.8
10.
S 9.9
1 9.9
9.7
9.7
S 9.6
9.6
WV
WV
9.80
9.8
9.7
9.2
9.3
9.3
9.19.26
9.27
9.29
9.23 9.
14 9.2
9.7
9.79 9.73
9.5
9.73
9.
9.88
9.3
9.97 9.98
9.5
9.4
9.7
9.8 79.6
9.8
9.8
9.
10.00
9.7
9.3
9.97 10.10
2' CURB & GUTTER
CONCRETE SIDEWALK
R A
M P
C O
V E
R E
D C
O N
C
10.
10.
22 9.49
9.4 69.4
9.4
9.4 5 9.3
7 9.4
9.4
9.4 7 9.53 9.5
910.01
10003
E
CONC.
GRASS
GRASS
CONCRETE
GRASS
GRASS
CONC.
CONC.
METAL STAIRS
CONC.
CONC. CONC.
CONC. SIDEWALK
HEDGE
P
LA
N
TE
R
CONC.
GRASS
GRASS
GRASS
GRASS
GRASS
CONC.
SET PRM
N 625576.0250 E 936655.7668N88°06'37"E
N
°3 7'
"E 30
9.
C L
CL
.0
' F P
L E
A S
E M
E N
T O
.R .B
.4
, P
G .1
4, B .C
.R
W. DANIA BEACH BOULEVARD
(PLATTED AS COCOANUT AVENUE)
50.0' RIGHT-OF-WAY (P.B. B, PG. 49, D.C.R.)
.0
PARCEL 'B'
DANIA BEACH CITY CENTER
P.B. 179, PG. 137, B.C.R.
2.84 ACRES
10.0'
.0
C O
N C
. W A
LK
4.
T O
T A
L)
N .W
. 3 R
D A
V E
N U
E (P
LA
TT
E D
A S
D A
N
IA
A V
E N
U E
.0 ' R
IG
H
T -O
F -W
A Y
P
.B . B
, P G
. 4 9, M .D
.C .R
WV
9.3
9.76
9.87
9.9
9.689.51
10.
9.5
10.
9.70 9.7
.0
WV
WV
9.8
9.8
9.8
9.849.
9.
9.59
9.759.74
9.34
10.
10.
9.60 9.499.28
9.52
9.72 9.7
9.75
9.73
9.7 110.
11.26
10.8710.
10.
10.
10.
9.9
9.
629.51
10.24
.41
9.
.12 10.38
10.
10.
10.
069.99
9.9
9.
9.7
10.
10.
10.5710 .5
10.
10.40
9.82
.049.88
9.8
11.
10.
TEL
S
10.
10.
9.79.8
E
COVERED BUS BENCH
A S
P H
G R
AS
S
C O
N C
R
ET
E
SI
D
EW
AL
K
EL
EC
11.
M
M9.4
11.
9.4
9.7
10.
10.3810.43 10.46
10.51
10.60
10.
10.
10.
10.67
10.
11.
10.
.6
.6010 .56
10.52
10.46
10.44 10 .4
10.65
10.45
.32
.04
10.
0510.05
10.
9.67
9.9
10.
10.
FOLIO: 5042-34-62-0020
OWNER: CITY OF DANIA BEACH
ADDRESS: 100 W. DANIA BEACH BLVD.
ASPHALT PARKING
EDGE OF PAVEMENT
G R
AS
S
G R
AS
S
R A
M P
STEP STEP
GRASS
RIM EL.=9.58'
INV.EL. = (-)0.02' (N) 8" PVC
INV. EL. = 4.28' (S) 8" PVC
INV. EL. = (-)0.02' (S) 8" PVC
INV. EL. = (-)0.20' (E) 8" PVC RIM EL.=9.97'
INV.EL. = (-)0.69' (W) 8" PVC
INV. EL. = (-)0.89' (E) 8" PVC
PB
DANIA BEACH BLVD.
SIDEWALK REPAIR
SEE STRUCTURAL PLANS
EXIST. BUS SHELTER
AND SLAB TO REMAIN
CONTRACTOR SHALL REGRADE
EXISTING SWALE TO ALLOW
STORMWATER TO EXISTING
RETENTION AREA
PROPOSED GENERATOR
SEE ELECTRICAL PLANS
SHEET PILE, SEE
STRUCTURAL PLANS
EXIST. GENERATOR
ENCLOSURE AND PAD
TO BE MODIFIED. SEE
STRUCTURAL PLANS
SOD RESTORATION
F.F.E.
+12.40'
NW
3R
D
AV
E.
C O
N C
R E
TE
S
ID
E
W A
LK
(P
LA
T
22.5'
29.8'
COMMUNITY LIBRARY
FLOOR ELEVATION = 11.42'(NAVD88)
59.5'
17.4'
16.4'
38.4'
14.8'
22.4'
25.0'
.5
.8
.5
.1
' C
O V
E R
E D
C O
N C
R E
TE
W
A
LK
.3
.7
.1
16.3'
C O
N C
. W A
LK
HEADER CURB
A S
P H
A
LT
P A
V E
M E
N T
10.
FOUND NAIL
LS 3487
5/ 8"
F C
IR
L B
FIR (5/8")
LB 3487
FND
FNC
LB 6448
FND
3/4"PIPE
NO ID
M
H Y D
GV
GV
GV
GAS
N O
P A
R K
IN
G
W. DANIA BEACH BOULEVARD
(PLATTED AS COCOANUT AVENUE)
50.0' RIGHT-OF-WAY (P.B. B, PG. 49, D.C.R.)
N .W
. 1 S
T A
V E
N U
E
(P
LA
TT
E
D A
S C
O P
E N
H A
G E
N A
V E
N U
E
.0
' R
IG
H T
-O F
-W A
Y
P .B
B
P
G D
.C .R
C O
N C
. W A
LK
CONC. WALK
N .W
. 3 R
D A
V E
N U
E (P
LA
TT
E D
A S
D A
N
IA
A V
E N
U E
.0 ' R
IG
H
T -O
F -W
A Y
P
.B . B
, P G
. 4 9, M .D
.C .R
TEL
CONC. WALK
A S
P H
A
LT
P A
V E
M E
N T
PB
SITE PLAN
BID SET
NOT FOR CONSTRUCTION
DANIA BEACH CITY HALL WIND PROTECTION
DANIA BEACH, FLORIDA
( IN FEET )
GRAPHIC SCALE
10 4020
1"=20'
NONO DATE REVISION BY REVISIONDATE BY
SCALE
PROJECT No
SHEET
DATE:Fi le
N am e:
P :\P ro je ct s\
\2
D an ia B ea ch
E ng in ee rin g
S er vi ce s\
.1 D an ia
B ea ch W in d
P ro te ct io n
A nd
B ac ku p
P ow er T o C ity H al l\c ad d
Fi le s\ D ra w in gs
\2
-C -S
IT
E
-P
LA
N .d w g
P lo tte d by
M au ric io
G om ez o n
Tu es da y, A pr il
, 2
4:
:3
P
M
JENNA MARTINETTI, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 69035.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JENNA MARTINETTI, P.E. ON THE
DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
R
KNOW WHAT'S BELOW
A L WA Y S C A L L 8 1 1
B E F O R E Y O U D I G
It's fast. It's free. It's the law.
www.callsunshine.com
04/21/2026 2259171
AS SHOWN C1
NOTES:
1. CONTRACTOR SHALL FIELD VERIFY EXTENTS OF NECESSARY DEMOLITION AND
EXPOSE EXISTING UTILITIES AT CONFLICT POINTS PRIOR TO CONSTRUCTION OF
ELECTRICAL CONDUIT.
2. CONTRACTOR SHALL TAKE NECESSARY MEASURE TO PROTECT EXISTING UTILITIES
DURING DEMOLITION AND CONSTRUCTION.
3. CONTRACTOR SHALL USE CAUTION DURING CONSTRUCTION TO AVOID DAMAGING ALL
EXISTING TREES.
4. REFER TO STRUCTURAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL MODIFICATIONS
AND DETAILS.
5. CONTRACTOR SHALL COORDINATE WITH OTHER TRADES ROUTING OF UNDERGROUND
ELECTRICAL AND GAS REQUIREMENTS PRIOR TO START OF CONSTRUCTION.
6. UNDERGROUND ELECTRICAL CONDUITS & WIRING. SEE ELECTRICAL PLANS.
7. NEW EMERGENCY GENERATOR UNIT PURCHASED BY THE CITY, INSTALLED BY
CONTRACTOR ON STRUCTURAL CONCRETE PAD. SEE STRUCTURAL AND ELECTRICAL
PLANS.
8. ANY DAMAGE TO EXISTING TREES, SHRUBS, CURB SLABS, SIDEWALKS, OR EXISTING
ITEMS NOT SHOWN IN PLAN SHALL BE REPLACED AT THE CONTRACTOR'S COST TO
THE EXISTING CONDITION OR BETTER.
9. ANY IMPACT TO EXISTING SWALES OR SOD SHALL BE REPLACED TO MATCH EXISTING
ELEVATION AND FLOW PATTERNS.
10. CONTRACTOR SHALL SUBMIT TRAFFIC CONTROL PLAN/MAINTENANCE OF TRAFFIC
(MOT) PLAN FOR THE CITY FOR APPROVAL PRIOR TO STARTING WORK. MOT PLAN
SHALL INCLUDE PHASING AND TIMELINES FOR CONSTRUCTION AND MATERIAL
DELIVERIES FOR THE LIFE OF THE CONSTRUCTION PROJECT.
KEY MAP
CONCRETE
LANDSCAPING RESTORATION (HEDGE, SOD, MULCH)
GRAVEL RESTORATION
6" STEP
LEGEND:
NONO DATE REVISION BY REVISIONDATE BY
SCALE
PROJECT No
SHEET
DATE:Fi le
N am e:
P :\P ro je ct s\
\2
D an ia B ea ch
E ng in ee rin g
S er vi ce s\
.1 D an ia
B ea ch W in d
P ro te ct io n
A nd
B ac ku p
P ow er T o C ity H al l\c ad d
Fi le s\ D ra w in gs
\2
-C -D
TL
S
.d w g
P lo tte d by
M au ric io G om ez o n Tu es da y, A pr il
, 2
5:
:1
P M
JENNA MARTINETTI, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 69035.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JENNA MARTINETTI, P.E. ON THE
DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
R
KNOW WHAT'S BELOW
A L WA Y S C A L L 8 1 1
B E F O R E Y O U D I G
It's fast. It's free. It's the law.
www.callsunshine.com
04/21/2026 2259171
AS SHOWN C2
12"VARIES
6" O.
D.
" M
IN
D
.I.
P.
" M
IN
P.
V.
C
" M
IN
(H .D
.P .E
BOTTOM OF ROADWAY BASE
OR PERVIOUS GRADE
12"
SUITABLE BACKFILL PLACED IN
6" LAYERS COMPACTED TO
A DENSITY OF NOT LESS THAN
98% OF THE MAXIMUM DRY DENSITY
AS DETERMINED BY AASHTO T-180
2-1/2" MAX. ROCK DIAMETER
SELECT BACKFILL PLACED IN
6" LAYERS COMPACTED TO
A DENSITY OF NOT LESS THAN
95% OF THE MAXIMUM DRY DENSITY
AS DETERMINED BY AASHTO T-180
1" MAX. ROCK DIAMETER
PIPE BEDDING #57 STONE
WRAPPED IN FILTER FABRIC
(SEE NOTE 1)
NOTE:
1. SUITABLE BACKFILL SHALL BE IMPORTED AS NEEDED UP TO THE
BEDDING FOUNDATION.
2. INSTALL TRACEABLE WARNING TAPE DIRECTLY ABOVE ELECTRICAL
CONDUIT, 12 INCHES ABOVE CONDUIT.
3. INSTALL TRACEABLE WARNING TAPE DIRECTLY ABOVE GAS PIPE, 12
INCHES ABOVE PIPE.
4. INSTALL TRACER WIRE DIRECTLY ABOVE GAS PIPE.
TEMPORARY TRENCH PATCH
2" ASPHALT OR STEEL PLATE UNTIL
PAVEMENT RESTORATION IS COMPLETED.
SEE TECH. SPECIFICATIONS SECTION 01515
TRACEABLE WARNING TAPE
PIPE TRENCH IN SATISFACTORY SOILS
SCALE: N.T.S.
TYPE "B"
(SAWED JOINTS)
TYPE "A"
(EXPANSION JOINTS)
TYPE "A" JOINTTYPE "A" JOINT
TYPE "B" JOINT
TYPE "B" JOINT
TYPE "A" JOINT
TYPE "B" JOINT
REFER TO PLAN
5'
(TYPICAL)
1/2"
3/16"
SAWCUT
12" R.
1-12" (6" THICK)
1" (4" THICK)
20'
PLAN
ELEVATION
SECTION
1/2" PRE-MOLDED FIBEROUS EXPANSION
JOINT MATERIAL PER FDOT SPEC. 932-1.1
REFER TO PLAN
FOR LAYOUT DETAILS
1% MIN. TO 2% MAX.
WITH TRANSVERSE
HAIR BROOM FINISH
SIDEWALK JOINTS
TYPE LOCATION
20'-0" CENTER TO CENTER P.C. AND P.T. OF CURVES. JUNCTION OF EXISTING AND NEW
SIDEWALKS. WHERE SIDEWALK ABUTS CONCRETE CURBS, DRIVEWAYS, AND SIMILAR STRUCTURES
OR AT THE DISCRETION OF THE ENGINEER.
5'-0" CENTER TO CENTER ON SIDEWALKS THROUGHOUT THE SITE."B"
"A"
5% MAX.
LONGITUDINAL
SLOPE
12" R. IF TOOLED JOINTS
ARE SPECIFIED IN THE PLANS
ALT. TYPE "B"
(TOOLED JOINTS)
1-12" (6" THICK)
1" (4" THICK)
2"R TOOL
ALL EDGES
6"
(TYPICAL)
PORTLAND CEMENT CONCRETE
PER FDOT SPEC. 347 AND 522
2500 PSI @ 28 DAYS
4" THICK OR
6" THICK AT DRIVEWAYS
UNLESS OTHERWISE NOTED IN THE PLANS
SIDEWALK JOINTS
6" BASE COMPACTED TO
98% OF AASHTO T-180
DENSITY PER
FDOT SPECIFICATION 522
CONCRETE SIDEWALK
SCALE: N.T.S. CURRENT
BID SET
NOT FOR CONSTRUCTION
DETAILS
DANIA BEACH CITY HALL WIND PROTECTION
DANIA BEACH, FLORIDA
GENERAL ELECTRICAL NOTES:
1 - GENERAL REQUIREMENTS
ALL REQUIREMENTS UNDER DIVISION ONE AND THE GENERAL AND SUPPLEMENTARY CONDITIONS OF
THESE SPECIFICATIONS SHALL BE A PART OF THIS SECTION. THE CONTRACTOR SHALL BE
RESPONSIBLE TO BECOME THOROUGHLY FAMILIAR WITH ALL ITS CONTENTS AS TO REQUIREMENTS WHICH AFFECT THIS DIVISION. THE WORK REQUIRED UNDER THIS DIVISION INCLUDES ALL MATERIAL, EQUIPMENT, APPLIANCES, AND LABOR REQUIRED TO COMPLETE THE ENTIRE SYSTEM AS REQUIRED
BY THE DRAWINGS AND SPECIFICATIONS, OR REASONABLY INFERRED TO BE NECESSARY TO
FACILITATE EACH SYSTEMS FUNCTIONING AS INDICATED BY THE DESIGN AND THE EQUIPMENT
SPECIFIED. THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE A FULLY OPERATIONAL
ELECTRICAL SYSTEM AS PER THE INTEND SHOWN ON DRAWINGS AND SPECIFICATIONS.
2 - INSPECTION OF SITE
THE CONTRACTOR SHALL PERSONALLY INSPECT THE SITE OF THE PROPOSED WORK AND BECOME
FULLY INFORMED AS TO THE CONDITIONS UNDER WHICH THE WORK IS TO BE DONE. FAILURE TO
DO SO WILL NOT BE CONSIDERED SUFFICIENT JUSTIFICATION TO REQUEST OR OBTAIN EXTRA
COMPENSATION OVER AND ABOVE THE CONTRACT PRICE.
3 - MATERIAL AND WORKMANSHIP
ALL MATERIAL AND APPARATUS SHALL BE NEW AND IN FIRST CLASS CONDITION. ALL MATERIAL AND
APPARATUS SHALL HAVE MARKINGS OR A NAMEPLATE IDENTIFYING THE MANUFACTURER AND
PROVIDING SUFFICIENT REFERENCE TO ESTABLISH QUALITY, SIZE AND CAPACITY. ALL
WORKMANSHIP SHALL BE OF THE FINEST POSSIBLE BY EXPERIENCED MECHANICS OF THE PROPER TRADE. IN GENERAL, ALL MATERIALS AND EQUIPMENT SHALL BE OF COMMERCIAL SPECIFICATION GRADE IN QUALITY. LIGHT DUTY AND RESIDENTIAL TYPE EQUIPMENT WILL NOT BE ACCEPTABLE. ALL HOISTS, SCAFFOLDS, STAGING, RUNWAYS, TOOLS, MACHINERY AND EQUIPMENT REQUIRED FOR THE PERFORMANCE OF THE ELECTRICAL WORK SHALL BE FURNISHED BY THIS CONTRACTOR. MATERIAL AND EQUIPMENT SHALL BE STORED AND MAINTAINED IN CLEAN CONDITION, AND PROTECTED FROM
WEATHER, MOISTURE, AND PHYSICAL DAMAGE.
4 - COORDINATION
THE CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER CONTRACTORS AND SUBCONTRACTORS SO THAT VARIOUS COMPONENTS OF THE ELECTRICAL SYSTEMS WILL BE INSTALLED AT THE PROPER
TIME, WILL FIT THE AVAILABLE SPACE, AND WILL ALLOW PROPER SERVICE ACCESS TO ALL
EQUIPMENT. THE CONTRACTOR SHALL REFER TO ARCHITECTURAL, CIVIL, STRUCTURAL AND
MECHANICAL DRAWINGS AND TO RELEVANT EQUIPMENT DRAWINGS TO DETERMINE THE EXTENT OF
CLEAR SPACES. THE CONTRACTOR SHALL MAKE ALL OFFSETS REQUIRED TO CLEAR EQUIPMENT,
BEAMS AND OTHER STRUCTURAL MEMBERS, AND TO FACILITATE CONCEALING CONDUIT IN THE
MANNER ANTICIPATED IN THE DESIGN. THE CONTRACTOR SHALL PROVIDE MATERIALS WITH TRIM
WHICH WILL FIT PROPERLY THE TYPES OF CEILING, WALL, OR FLOOR FINISHES ACTUALLY
INSTALLED.
5 - DIMENSIONS AND LAYOUTS
THE DRAWINGS ARE SCHEMATIC IN NATURE, BUT SHOW THE VARIOUS COMPONENTS OF THE
SYSTEMS APPROXIMATELY TO SCALE AND ATTEMPT TO INDICATE HOW THEY ARE TO BE INTEGRATED WITH OTHER PARTS OF THE BUILDING. FIGURED DIMENSIONS SHALL BE TAKEN IN PREFERENCE TO
SCALE DIMENSIONS. DETERMINE EXACT LOCATIONS BY JOB MEASUREMENTS, BY CHECKING THE
REQUIREMENTS OF OTHER TRADES, AND BY REVIEWING ALL CONTRACT DOCUMENTS. THE
CONTRACTOR WILL BE HELD RESPONSIBLE FOR ERRORS WHICH COULD HAVE BEEN AVOIDED BY
PROPER CHECKING AND INSPECTION.
6 - ORDINANCES AND CODES
CONTRACTOR'S PERFORMANCE, WORKMANSHIP AND MATERIALS SHALL COMPLY WITH FBC 2023 (8th
EDITION) AND NEC 2020 CODES, STATE AND LOCAL BUILDING CODES, AND/OR ALL OTHER
APPLICABLE CODES AND ORDINANCES. CONTRACTOR SHALL COMPLY WITH RULES AND REGULATIONS OF PUBLIC UTILITIES AND MUNICIPAL DEPARTMENTS AFFECTED BY CONNECTION OF SERVICES.
CONTRACT SHALL OBTAIN AND PAY FOR ALL PERMITS.
7 - SUBSTITUTIONS
THIS SPECIFICATION PROVIDES THAT THE BASE BID OF ALL CONTRACTORS SHALL INCLUDE THE PRODUCTS SPECIFICALLY NAMED, THE CONTRACTOR BEING PERMITTED TO SUBMIT IN THE FORM OF ALTERNATES, WITH HIS PROPOSAL, PRODUCTS OF ANY OTHER MANUFACTURERS FOR SIMILAR USE, PROVIDED THE DIFFERENCE IN COST, IF ANY, IS SPECIFIED IN EACH CASE. THE TERMS
"APPROVED", "APPROVED EQUAL", OR "EQUAL" SHALL MEAN APPROVED BY THE ENGINEER AS AN ACCEPTABLE ALTERNATE BID. NO SUBSTITUTIONS WILL BE CONSIDERED THAT ARE NOT BID AS AN
ALTERNATE.
8 - SHOP DRAWINGS
SUBMIT FOR APPROVAL ELECTRONIC FILES OF MFR. SHOP DRAWINGS OF ALL MAJOR ITEMS OF
EQUIPMENT AND ALL ITEMS REQUIRING COORDINATION BETWEEN CONTRACTORS. BEFORE SUBMITTING
SHOP DRAWINGS AND MATERIAL LISTS, THE CONTRACTOR SHALL VERIFY THAT ALL EQUIPMENT
SUBMITTED IS MUTUALLY COMPATIBLE AND SUITABLE FOR THE INTENDED USE, AND SHALL FIT THE AVAILABLE SPACE AND ALLOW AMPLE ROOM FOR MAINTENANCE. THE ENGINEER'S CHECKING AND
SUBSEQUENT APPROVAL OF SUCH SHOP DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR FROM
RESPONSIBILITY FOR ERRORS IN DIMENSIONS, DETAILS, SIZE OF MEMBERS, OR QUANTITIES; OR OMISSIONS OF COMPONENTS OR FITTINGS; OR FOR COORDINATING ITEMS WITH ACTUAL BUILDING
CONDITIONS.
9 - ADJUSTING, ALIGNING AND TESTING
ALL ELECTRICAL EQUIPMENT ON THIS PROJECT FURNISHED UNDER THIS DIVISION AND ALL
ELECTRICAL EQUIPMENT FURNISHED BY OTHERS SHALL BE ADJUSTED, ALIGNED AND TESTED FOR PROPER OPERATION BY THE ELECTRICAL CONTRACTOR COMPLETE WIRING SYSTEMS SHALL BE FREE
FROM SHORT CIRCUITS. ALL MOTORS SHALL BE VERIFIED FOR PROPER ROTATION.
10 - OPERATION AND MAINTENANCE INSTRUCTIONS
SUBMIT TO THE ARCHITECT/ENGINEER THREE COPIES EACH OF MATERIAL FOR MAINTENANCE AND
OPERATION INSTRUCTION MANUALS, APPROPRIATELY BOUND INTO MANUAL FORM INCLUDING
APPROVED COPIES OF MANUFACTURERS CATALOG SHEETS, WIRING DIAGRAMS, MAINTENANCE
INSTRUCTIONS, OPERATING INSTRUCTIONS AND PARTS LISTS, REVISED IF NECESSARY TO SHOW SYSTEM AND EQUIPMENT AS ACTUALLY INSTALLED. CONTRACTOR SHALL ALSO PROVIDE ADEQUATE VERBAL INSTRUCTIONS OF SYSTEM OPERATION TO OWNER'S REPRESENTATIVE AT THE TERMINATION
OF THE WORK.
11 - START UP OF SYSTEMS
PRIOR TO START-UP OF THE ELECTRICAL SYSTEMS, THE CONTRACTOR SHALL CHECK ALL
COMPONENTS AND DEVICES, LUBRICATE ITEMS ACCORDINGLY, AND TIGHTEN ALL SCREWED AND
BOLTED CONNECTIONS. ADJUST TAPS ON EACH TRANSFORMER FOR RATED SECONDARY VOLTAGE.
CHECK AND RECORD BUILDING'S SERVICE ENTRANCE VOLTAGE, GROUNDING CONDITIONS,
GROUNDING RESISTANCE AND PROPER PHASING, BALANCE ALL SINGLE PHASE LOADS AT EACH
PANELBOARD, REDISTRIBUTING BRANCH CIRCUIT CONNECTIONS UNTIL BALANCE IS ACHIEVED.
REPLACE ALL BURNED OUT LAMPS. AFTER ALL SYSTEMS HAVE BEEN INSPECTED AND ADJUSTED, CONFIRM ALL OPERATING FEATURES REQUIRED BY THE DRAWINGS AND SPECIFICATIONS AND MAKE
FINAL ADJUSTMENTS AS NECESSARY.
12 - GUARANTEE
GUARANTEE AGAINST DEFECTIVE WORKMANSHIP AND MATERIAL FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL PAYMENT. GUARANTEE SHALL INCLUDE MATERIAL TO BE REPLACED AND ALL LABOR
REQUIRED.
13 - EXCAVATION AND BACKFILLING
DO ALL EXCAVATION OF ALL MATERIALS ENCOUNTERED INCLUDING ROCK REQUIRED FOR WORK
UNDER THIS SECTION. BACKFILL ALL TRENCHES, TAMPING WELL IN 6" LAYERS. SYSTEM SHALL BE
TESTED, MADE TIGHT AND ACCEPTED BEFORE BACKFILL. REMOVE FROM PREMISES ALL EXCESS
MATERIAL NOT USED IN BACKFILLING. REPAIR ALL STREETS, SIDEWALKS, DRIVES, PAVING, ETC.
DAMAGED. REPAIR MATERIALS SHALL GENERALLY MATCH EXISTING CONSTRUCTION. ALL BACKFILLING AND REPAIRING SHALL MEET ALL REQUIREMENTS OF THE CITY AND OTHERS HAVING JURISDICTION.
REPAIR WORK SHALL BE THOROUGHLY FIRST CLASS. CONFORM TO ALL REQUIREMENTS OF DIVISION
TWO OF THIS SPECIFICATION.
14 - CLEANING
DIRT AND REFUSE RESULTING FROM THE PERFORMANCE OF THE WORK SHALL BE REMOVED FROM
THE PREMISES AS REQUIRED TO PREVENT ACCUMULATION. THE CONTRACTOR SHALL COOPERATE IN
MAINTAINING REASONABLY CLEAN PREMISES AT ALL TIMES. IMMEDIATELY PRIOR TO FINAL
INSPECTION, THE CONTRACTOR SHALL MAKE A FINAL CLEANUP OF DIRT AND REFUSE RESULTING FROM HIS WORK. THE CONTRACTOR SHALL CLEAN ALL MATERIAL AND EQUIPMENT INSTALLED UNDER
THE ELECTRICAL CONTRACT. DIRT, DUST, PLASTER, STAINS AND FOREIGN MATTER SHALL BE
REMOVED FROM ALL SURFACES. DAMAGED FINISHES SHALL BE TOUCHED UP AND RESTORED TO
THEIR ORIGINAL CONDITION.
16 - CUTTING AND PATCHING
THIS CONTRACTOR SHALL DO ALL CUTTING OF WALLS, CEILINGS, ETC. AS REQUIRED TO INSTALL WORK UNDER THIS SECTION. CONTRACTOR SHALL OBTAIN PERMISSION OF THE ENGINEER BEFORE
DOING ANY CUTTING. ALL HOLES SHALL BE CUT AS SMALL AS POSSIBLE. CONTRACTOR SHALL
PATCH WALLS, FLOORS, ETC. AS REQUIRED BY WORK UNDER THIS SECTION. ALL PATCHING SHALL BE THOROUGHLY FIRST CLASS AND SHALL MATCH THE ORIGINAL MATERIAL AND CONSTRUCTION.
16 - ROUGH-IN
COORDINATE WITHOUT DELAY ALL ROUGHING-IN WITH GENERAL CONSTRUCTION. ALL CONDUIT
ROUGH-IN SHALL BE CONCEALED EXCEPT IN UNFINISHED AREAS AND WHERE OTHERWISE SHOWN.
17 - CONDUIT
ALL CONDUIT SHALL BE RUN CONCEALED WHEN POSSIBLE UNLESS OTHERWISE NOTED. ALL
CONDUIT RUN UNDERGROUND SHALL BE PVC SCH. 40 UNLESS NOTED OTHERWISE, EXPOSED TO
WEATHER OR OTHER HAZARDOUS CONDITIONS SHALL BE METAL RIGID PVC COATED U.N.O. ALL
CONDUITS SHALL BE PROVIDE WITH GROUND WIRE. FINAL CONNECTION TO EACH MOTOR AND
TRANSFORMER, AND TO ANY DEVICE WHICH WOULD OTHERWISE TRANSMIT MOTION, VIBRATION OR NOISE, SHALL BE IN FLEXIBLE METAL CONDUIT. WHERE FLEXIBLE METAL CONDUIT IS EXPOSED TO LIQUIDS, VAPORS OR SUNLIGHT, LIQUID-TIGHT FLEXIBLE METAL CONDUIT SHALL BE USED. ALL FLEXIBLE METAL CONDUIT SHALL BE PROVIDED WITH AN INSULATED GROUND WIRE. CONTRACTOR
SHALL REFER TO CONSTRUCTION DOCUMENTS FOR ADDITIONAL REQUIREMENTS.
18 - CONDUIT INSTALLATION
A. ALL WIRING SHALL BE RUN IN CONDUIT.
B. CONDUIT SHALL BE INSTALLED CONCEALED ABOVE SUSPENDED CEILINGS OR CONCEALED IN
WALLS OR FLOORS WHEREVER POSSIBLE. RUN PARALLEL TO BUILDING LINES.
C. CONDUIT SHALL BE INSTALLED TO REQUIREMENTS OF STRUCTURE AND TO REQUIREMENTS
OF ALL OTHER WORK ON THE PROJECT. CONDUIT SHALL BE INSTALLED TO CLEAR ALL
OPENINGS, DEPRESSIONS, PIPES, DUCTS, REINFORCING STEEL, ETC. CONDUIT SET IN
FORMS FOR CONCRETE STRUCTURE SHALL BE INSTALLED IN SUCH A MANNER THAT
INSTALLATION WILL NOT AFFECT THE STRENGTH OF THE STRUCTURE. EXCEPT WHERE
APPROVED IN WRITING BY THE ENGINEER, NO CONDUIT SHALL BE RUN IN A SLAB ON
GRADE. CONDUIT SHALL BE LOCATED IN GRANULAR FILL BELOW SLABS-ON GRADE. NO
ELECTRICAL ROOM SLAB CUTTING ALLOWED.
D. CONDUITS SHALL BE INSTALLED CONTINUOUS BETWEEN CONNECTIONS TO OUTLETS, BOXES
AND CABINETS WITH A MINIMUM POSSIBLE NUMBER OF BENDS AND NOT MORE THAN THE
EQUIVALENT OF FOUR 90 BENDS BETWEEN CONNECTIONS. BENDS SHALL BE SMOOTH AND
EVEN AND SHALL BE MADE WITHOUT FLATTENING CONDUIT OR FLAKING ENAMEL. RADIUS
OF BENDS SHALL BE AS LONG AS POSSIBLE AND NEVER SHORTER THAN THE
CORRESPONDING TRADE ELBOW. LONG RADIUS ELBOWS SHALL BE USED WHERE
NECESSARY.
E. CONDUITS SHALL BE SECURELY FASTENED IN PLACE WITH APPROVED STRAPS, HANGERS
AND STEEL SUPPORTS AS REQUIRED. SINGLE CONDUITS FOR FEEDERS SHALL BE HUNG
WITH MALLEABLE SPLIT RING HANGERS WITH ROD AND TURNBUCKLE SUSPENSION FROM
INSERTS SPACED NOT OVER 10 FEET APART IN CONSTRUCTION ABOVE. GROUPS OF
HORIZONTAL FEEDER CONDUITS SHALL BE CLAMPED TO UNISTRUT STEEL CHANNELS AND
SUSPENDED FROM INSERTS SPACED NOT OVER 10 FEED APART IN CONSTRUCTION ABOVE.
VERTICAL FEEDER CONDUITS SHALL BE SECURELY CLAMPED TO STRUCTURAL STEEL
MEMBERS ATTACHED TO STRUCTURE. CABLE CLAMPS SHALL BE INSTALLED FOR SUPPORT
OF VERTICAL FEEDERS WHERE REQUIRED. CONDUIT SUPPORTS SHALL BE ADDED WITHIN
12" AT ONE END OF ALL BENDS. CONDUIT SHALL NOT BE SUPPORTED FROM SUSPENDED
CEILING COMPONENTS.
F. CONDUIT ENDS SHALL BE REAMED BEFORE INSTALLATION AND ALL CONDUIT SHALL BE
THOROUGHLY CLEANED BEFORE INSTALLATION AND KEPT CLEAN AFTER INSTALLATION.
OPENINGS AND BOXES SHALL BE PLUGGED OR COVERED AS REQUIRED TO KEEP CONDUIT
CLEAN DURING CONSTRUCTION AND ALL CONDUIT SHALL BE FISHED CLEAR OF
OBSTRUCTIONS BEFORE THE PULLING OF WIRES. ALL CONDUIT SHALL BE OF AMPLE SIZE
FOR PULLING OF WIRE AND SHALL NOT BE SMALLER THAN CODE REQUIREMENTS AND NOT
LESS THAN 3/4" IN SIZE, UNLESS OTHERWISE NOTED.
G. ALL ELECTRICAL WORK SHALL BE PROTECTED AGAINST DAMAGE DURING CONSTRUCTION.
ANY WORK DAMAGED OR MOVED OUT OF LINE AFTER ROUGHING-IN SHALL BE REPAIRED
TO MEET ENGINEER'S APPROVAL WITHOUT ADDITIONAL COST TO OWNER.
H. CONDUIT TERMINATIONS AT PANELBOARDS AND JUNCTION BOXES SHALL BE ALIGNED AND
INSTALLED TRUE AND PLUMB.
I. INSTALL APPROVED EXPANSION FITTINGS WHERE CONDUIT OR E.M.T. PASSES THROUGH
EXPANSION JOINTS.
J. INSTALL A PULL WIRE IN EACH EMPTY CONDUIT WHICH IS LEFT BY THE CONTRACTOR FOR
INSTALLATION OF WIRES OR CABLES BY OTHERS.
K. MAKE ALL JOINTS AND CONNECTIONS IN A MANNER WHICH WILL INSURE MECHANICAL
STRENGTH AND ELECTRICAL CONTINUITY.
L. THRU-WIRING OF LIGHT FIXTURES IS NOT PERMITTED.
M. METALLIC CONDUIT IN DIRECT CONTACT WITH EARTH SHALL BE COATED PVC COATED STEEL
CONDUITS AND FITTINGS FOR THIS APPLICATION, UNLESS OTHERWISE NOTED. TRANSITION
FROM UNDERGROUND PVC CONDUIT TO ABOVE GROUND SHALL BE METAL RIGID PVC
CONDUIT FROM BELOW GROUND ELBOW TO 12" ABOVE GROUND.
19 - BUSHINGS AND LOCKNUTS
WHERE CONDUITS ENTER BOXES, THEY SHALL BE RIGIDLY CLAMPED TO THE BOX BY BUSHING ON THE INSIDE AND A LOCKNUT ON THE OUTSIDE AND CONDUIT SHALL ENTER THE BOX SQUARELY.
BUSHINGS AND LOCKNUTS SHALL BE MADE OF GALVANIZED MALLEABLE IRON AND SHALL HAVE
SHARP, CLEAN-CUT THREADS. WHERE THIN-WALL CONDUIT ENTERS BOX, PROVIDE APPROVED
E.M.T. CONNECTORS. USE INSULATED GROUNDING BUSHINGS WHEREVER CONNECTION IS SUBJECT
TO VIBRATION OR MOISTURE.
20 - WIRE
ALL WIRE SHALL HAVE COPPER CONNECTORS WITH U.L. LABEL, AND 600 VOLT INSULATION. ALL
WIRE SHALL BE RUN IN CONDUIT. SERVICE ENTRANCE CABLE SHALL BE TYPE USE, THWN OR
XHHW WITH STRANDED CONDUCTORS. ALL FEEDER AND BRANCH CIRCUIT WIRE #8 AWG AND
LARGER SHALL BE TYPE THWN OR XHHW, BOTH WITH STRANDED CONDUCTORS. ALL WIRE #10 AWG
AND SMALLER SHALL BE TYPE THWN (WET OR DAMP LOCATIONS, OR IN CONDUIT BELOW GRADE
OR SLAB) OR THWN (DRY LOCATIONS ONLY AND ABOVE GRADE), BOTH WITH SOLID CONDUCTORS.
WIRE WITHIN LED FIXTURE CHANNELS SHALL BE TYPE THHN. ALL BRANCH CIRCUIT WIRING SHALL BE NOT SMALLER THAN #12 AWG WIRE. CONTROL WIRING SHALL HAVE 600V INSULATION AND BE OF THE PROPER TYPE, SIZE AND NUMBER AS REQUIRED TO ACCOMPLISHED SPECIFIED FUNCTION.
21 - WIRING INSTALLATION
A. ALL WIRING SHALL BE INSTALLED IN APPROVED RACEWAY AND ENCLOSURES.
B. SUPPORT ALL WIRE AND CABLES IN VERTICAL INSTALLATIONS AS REQUIRED BY CODE BY
INSTALLING CABLE SUPPORTERS OR PLUG-TYPE CONDUIT RISER SUPPORTS.
C. ALL WIRE AND CABLE IN CONDUIT SHALL BE CONTINUOUS WITHOUT TAPS OR SPLICES. ALL
SPLICES OR TAPS SHALL OCCUR IN APPROVED BOXES AND ENCLOSURES AND SHALL BE
KEPT TO THE MINIMUM REQUIRED AND SHALL BE MADE UP WITH APPROVED SOLDERLESS
CONNECTORS. ALL SPLICES, TAPS, AND JOINTS SHALL BE INSULATED AS REQUIRED BY
CODE.
D. ALL MATERIALS USED TO TERMINATE, SPLICE OR TAP CONDUCTORS SHALL BE DESIGNED
FOR, PROPERLY SIZED FOR, AND U.L. LISTED FOR THE SPECIFIC APPLICATION AND
CONDUCTORS INVOLVED, AND SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE
MANUFACTURER'S RECOMMENDATIONS, USING THE MANUFACTURER'S RECOMMENDED TOOLS.
E. WHERE WIRE IS INDICATED TO BE INSTALLED, BUT THE CONNECTION IS INDICATED
"FUTURE" OR "BY OTHERS", CONTRACTOR SHALL LEAVE A MINIMUM OF 3 FEET OF
"PIGTAIL" AT THE BOX, TAPE THE ENDS OF THE CONDUCTORS, AND COVER THE BOX.
F. THE NUMBER OF CONDUCTORS IN A SPECIFIC CONDUIT RUN ARE INDICATED WITH CROSS
LINES ON EACH "CONDUIT RUN" ON THE DRAWINGS. IN GENERAL, DIRECTION OF BRANCH
CIRCUIT "HOME RUN" ROUTING IS INDICATED ON THE DRAWINGS, COMPLETE WITH CIRCUIT
NUMBERS AND PANELBOARD DESIGNATION. THE CONTRACTOR SHALL CONTINUE ALL SUCH
"HOME RUN" WIRING TO THE DESIGNATED PANELBOARD, AS THOUGH "CONDUIT RUNS"
WERE INDICATED IN THEIR ENTIRETY.
G. CONDUCTORS SHALL HAVE INSULATION OF THE PROPER COLOR TO MATCH NEC COLOR
CODE SYSTEM. IN LARGER WIRE SIZES WHERE PROPERLY COLORED INSULATION IS NOT
AVAILABLE, THE CONTRACTOR SHALL USE VINYL PLASTIC ELECTRICAL TAPE OF THE
APPROPRIATE COLOR AROUND EACH CABLE AT ALL TERMINATION POINTS, JUNCTION AND
PULL BOXES.
H. ALL TERMINAL BLOCKS AND WIRE TERMINALS FOR CONTROL WIRING SHALL BE PROPERLY
NUMBERED FOR IDENTIFICATION WITH VINYL STICK-ON MARKERS OR EQUIVALENT.
I. ALL BRANCH CIRCUITS SHALL HAVE AN EQUIPMENT GROUND CONDUCTOR INSTALLED IN
THE BRANCH CIRCUIT RACEWAY, SIZED IN ACCORDANCE WITH NEC TABLE 250-95 UNLESS
NOTED OTHERWISE.
J. VOLTAGE DROP IN BRANCH CIRCUITS SHALL NOT EXCEED 3%.
22 - JUNCTION BOXES, PULL BOXES, CABINETS AND WIREWAYS
PROVIDE JUNCTION BOXES, PULL BOXES, CABINETS AND WIREWAYS WHEREVER NECESSARY FOR
PROPER INSTALLATION OF VARIOUS ELECTRICAL SYSTEMS ACCORDING TO THE NATIONAL ELECTRICAL CODE AND WHERE INDICATED ON THE DRAWINGS. SIZE AS REQUIRED FOR THE SPECIFIC FUNCTION OR AS REQUIRED BY THE NATIONAL ELECTRICAL CODE, WHICHEVER IS LARGEST. CONSTRUCTION
SHALL BE OF A NEMA DESIGN SUITABLE FOR THE ENVIRONMENT INSTALLED.
23 - OUTLET BOXES
ALL OUTLETS INCLUDING LIGHT, SWITCH, RECEPTACLE, AND SIMILAR OUTLETS, SHALL BE NATIONAL ELECTRICAL, APPLETON, STEEL CITY, RACO OR APPROVED EQUAL GALVANIZED STEEL KNOCKOUT BOXES, SUITABLE IN DESIGN TO THE PURPOSE THEY SERVE AND THE SPACE THEY OCCUPY. SIZE AS REQUIRED FOR THE SPECIFIC FUNCTION OR AS REQUIRED BY THE NATIONAL ELECTRICAL CODE, WHICHEVER IS LARGEST. ALL OUTLET BOXES SHALL BE SET IN WALLS, COLUMNS, FLOORS, OR
CEILINGS SO AS TO BE FLUSH WITH THE FINISHED SURFACE AND BE ACCURATELY SET AND
RIGIDLY SECURED IN POSITION. PROVIDE PLASTER RINGS, EXTENSION RINGS AND MASONARY RINGS
AS REQUIRED FOR FLUSH MOUNTING.
24 - OUTLET LOCATIONS
OUTLETS ARE ONLY APPROXIMATELY LOCATED ON THE SMALL SCALE PLANS, AND GREAT CARE
MUST BE USED IN THE ACTUAL LOCATION BY CONSULTING THE VARIOUS LARGE SCALE DETAILED
DRAWINGS USED BY OTHER CONTRACTORS, AND BY SECURING DEFINITE LOCATIONS FROM THE
ARCHITECT. THE HEIGHT OF THE CENTER OF OUTLETS ABOVE THE FINISHED FLOOR, IF NOT
OTHERWISE SPECIFIED OR SHOWN ON THE DRAWINGS, SHALL GENERALLY BE AS FOLLOWS: SWITCH
OUTLETS: 48" ABOVE FLOOR TO TOP OF OUTLET WALL RECEPTACLES, 18" ABOVE FLOOR TO
BOTTOM OF OUTLET DEVICES ABOVE COUNTERS, 10" ABOVE COUNTER TO TOP OF OUTLET.
25 - WIRING DEVICES
FURNISH AND INSTALL THE OUTLETS AND SWITCHES WHERE SHOWN ON PLANS OR REQUIRED.
MINOR CHANGES RELATIVE TO THE LOCATION OF ELECTRICAL EQUIPMENT MAY BE MADE BY THIS CONTRACTOR TO COMPLY WITH STRUCTURAL AND BUILDING REQUIREMENTS AS DETERMINED IN THE COURSE OF CONSTRUCTION. ALL OUTLETS AND SWITCHES MUST BE OF THE SAME MANUFACTURER AND NOT MIXED ON THE PROJECT. COLOR AND TYPE OF SWITCHES AND RECEPTACLES SHALL BE AS REQUESTED BY THE ARCHITECT AND/OR ENGINEER, 20A DECORA TYPE ARE THE BASE FOR BID.
WIRING DEVICES MANUFATURED BY HUBBELL, LEVITON, ARROW-HART, BRYANT AND GENERAL
ELECTRIC WILL BE ACCEPTABLE.
26 - SWITCH AND OUTLET COVER PLATES
ALL SWITCH AND OUTLET PLATES SHALL MATCH TYPE OF WIRING DEVICES. SWITCH PLATES IN UNFINISHED ROOMS AND SPACES SHALL BE STAMPED STEEL PLATES, CADMIUM PLATED. GROUPS OF SWITCHES SHALL BE UNDER ONE GANG-PLATE MOUNTED HORIZONTALLY. PLATES SHALL BE SET
PLUMB, PARALLEL, AND SHALL FINISH FLUSH WITH THE WALL. WEATHERPROOF COVER PLATES
SHALL BE STAINLESS STEEL TYPE 302 WITH PVC GASKETING FOR SWITCHES. WEATHERPROOF
COVERS FOR OUTLETS SHALL BE EXTRA-DUTY AND AND IN-SUE TYPE. COVER SHALL BE WITH
SEPARATE LIFT COVERS FOR EACH DEVICE. CEILING RECEPTACLES SHALL BE WHITE OR MATCH
CEILING COLOR.
27 - PRESTOPPING OF FLOOR AND WALL PENETRATIONS
THIS CONTRACTOR SHALL SEAL ALL PENETRATIONS THROUGH FIRE RATED FLOOR AND WALL
ASSEMBLIES IN ACCORDANCE WITH NFPA CODES AND U.L. WALL CONSTRUCTION TYPES. THE
SEALING SYSTEM MUST BE CAPABLE OF PASSING A THREE HOUR TEST, PER ASTM E-814 (UL
1479). PENETRATION SEALING SYSTEM SHALL BE, AT A MINIMUM, 3M BRAND 7904 (CP-25 CAULK
OR 303 PUTTY), OR APPROVED EQUAL, AND SHALL BE INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS.
28 - FLASHING AND PITCH POCKETS
FLASH AND COUNTERFLASH ALL OPENINGS THROUGH ROOF, AND/OR PROVIDE PITCH POCKETS AS REQUIRED. ALL ROOF PENETRATIONS SHALL BE LEAKTIGHT AT THE TERMINATION OF THE WORK.
29 - EQUIPMENT IDENTIFICATION
THIS CONTRACTOR SHALL FURNISH AND INSTALL EQUIPMENT IDENTIFICATION NAMEPLATES ON ALL PANELBOARDS, TIMESWITCHES, ETC. INCLUDING SWITCHES IN DISTRIBUTION PANELS. NAMEPLATES SHALL BE ENGRAVED PHENOLIC PLASTIC, AND SHALL BE FIRMLY ATTACHED TO THE EQUIPMENT.
NAMEPLATES SHALL CLEARLY IDENTIFY EACH ITEM AND WHAT IT CONTROLS.
30 - ELECTRICAL SERVICE
SEE DRAWINGS FOR TYPE, SIZE, VOLTAGE, PHASE, ETC.
31 - CONNECTION TO SERVING UTILITIES
CONTRACTOR SHALL PROVIDE PROPER TERMINATION, METERING PROVISIONS, ETC. FOR ELECTRICAL AND TELEPHONE SERVICES FOR CONNECTION BY THE SERVING UTILITY, IN STRICT COMPLIANCE WITH THE REQUIREMENTS OF ALL CODES HAVING JURISDICTION AND OF THE SERVING UTILITY INVOLVED. ALL SERVICE TERMINATIONS AND CONNECTION POINTS SHALL BE VERIFIED IN THE FIELD BY THIS CONTRACTOR, AND HE SHALL WORK IN CONJUNCTION WITH THE UTILITY INVOLVED IN THE INSTALLATION OF ALL SERVICES. THIS CONTRACTOR SHALL PROVIDE ALL CONDUIT, ACCESSORIES, ETC. REQUIRED FOR COMPLETE UTILITY CONNECTION AND NOT FURNISHED BY THE SERVING
UTILITY. THE CONTRACTOR SHALL NOTIFY THE UTILITY COMPANIES INVOLVED WITHIN TWO WEEKS
AFTER NOTICE TO PROCEED, OF ALL REQUIRED INFORMATION NECESSARY IN ORDER FOR THE
UTILITY TO SUPPLY THE PROJECT WITHOUT DELAY. ELECTRICAL CONTRACTOR SHALL PAY ALL
CHARGES OF THE SERVING UTILITY FOR THE ELECTRICAL SERVICE.
32 - GROUNDING
THE ELECTRICAL SERVICE, ALL TRANSFORMERS, CONDUCTORS, CONDUITS, MOTOR FRAMES, ETC. IN THIS CONTRACT WHICH REQUIRE GROUNDING SHALL BE PERMANENTLY AND EFFECTIVELY GROUNDED
BY THIS CONTRACTOR IN A THOROUGH AND EFFICIENT MANNER IN CONFORMANCE TO THE
NATIONAL ELECTRICAL CODES.
35 - DISCONNECT SWITCHES
CONTRACTOR SHALL FURNISH AND INSTALL SQUARE D, SIEMENS, CUTLER-HAMMER, OR GENERAL
ELECTRIC FUSED OR NON-FUSED (AS NOTED OR REQUIRED) NEMA HEAVY DUTY EXTERNALLY
OPERATED SAFETY SWITCHES WHERE NOT FURNISHED WITH THE STARTING EQUIPMENT, AND AT ALL OTHER POINTS REQUIRED BY CODE. FUSE HOLDERS SHALL HAVE CLASS R REFECTION FEATURE.
CONSTRUCTION SHALL BE OF A NEMA 4X S.S. SUITABLE FOR THE ENVIRONMENT INSTALLED IN.
36 - FUSES
EACH CIRCUIT AND SET OF FUSE CLIPS THROUGHOUT THE JOB SHALL BE EQUIPPED WITH
BUSSMAN OR EQUIVALENT SHAWMUT FUSES, SIZE AND TYPE AS REQUIRED OR INDICATED. ALL
FUSES LARGER THAN 600 AMPS, SHALL BE U.L. CLASS L, SIMILAR TO TYPE KRP-C. BUSSMAN
LOW PEAK OR EQUIVALENT. FUSES USED TO PROTECT MOTORS SHALL BE U.L. CLASS RK5,
BUSSMAN FUSETRON OR EQUIVALENT. ALL FUSIBLE SWITCHES THROUGHOUT THE PROJECT SHALL HAVE FUSE HOLDERS WITH CLASS R REJECTION FEATURE. ALL FUSED DEVICES SHALL BE LABELED
AS TO TYPE AND SIZE OF FUSE REQUIRED.
38 - CONTRACTOR TO OWNER COORDINATION
CONTRACTOR SHALL COORDINATE WITH OWNER THE WHOLE ELECTRICAL INSTALLATION. NO
EXPOSED HARDWARE IS ALLOWED UNLESS SITE CONDITIONS DOES NOT ALLOW HARDWARE
CONCEALMENT. THE OWNER RESERVES THE RIGHT TO REJECT INSTALLATION NOT DONE PER HIS
STANDARDS. THE WHOLE ELECTRICAL INSTALLATION SHALL BE PERFORMED PER OWNER AND
MAXIMUM SECURITY FACILITY STANDARDS. CONTRACTOR SHALL OBTAIN ALL OWNER REQUIREMENTS
PRIOR TO FINAL BID. ALL PHASES OF CONSTRUCTION SHALL BE COORDINATED WITH OWNER
PRIOR TO START OF CONSTRUCTION.
39 - BIDDING AND COORDINATION
THE CONTRACTOR SHALL PROVIDE A FULLY OPERATIONAL ELECTRICAL, I.C. AND ELECTRICAL
ROUGH-INS FOR OTHER TRADES SYSTEMS BASED ON ALL APPLICABLE CODES. CONTRACTOR SHALL NOT MAKE ANY ASSUMPTIONS DURING BIDDING. CONTRACTOR SHALL VISIT THE SITE AND VERIFY EXISTING CONDITIONS. CONTRACTOR SHALL NOTIFY ENGINEER OF ANY CONFLICTS, ERRORS AND OMISSION ON DRAWINGS DURING BIDDING AND PRIOR TO FINAL BID. FAILURE TO NOTIFY ANY OF THE ABOVE, THE CONTRACTOR ASSUMES FULL RESPONSIBILITY, MONEYS, CHANGES AND CHARGES.
NO ADDITIONAL MONEYS WILL BE CONSIDERED AFTER JOB IS AWARDED UNLESS ANY CHANGE
COMES FROM OWNER. CONTRACTOR SHALL BE PROVIDED WITH A FULL SET OF BIDDING
DOCUMENTS FOR PROPER BIDDING AND COORDINATION WITHIN ALL TRADES. CONTRACTOR SHALL
PROVIDE ALL REQUIRED HARDWARE AND CONNECTIONS AS PER OTHER TRADES REQUIREMENTS
DURING BIDDING COORDINATION AS DICTATED HEREIN.
40. - CONTRACTOR'S RESPONSIBILITY AND CONTRACT REQUIREMENT:
THE CONTRACTOR SHALL INCLUDE IN HIS BID PROPOSAL "LINE ITEM" ADD/ALTERNATE FOR OF THE
FOLLOWING:
A. AS-BUILT CERTIFICATION DOCUMENTING ALL, PRIOR TO INSTALLATION, APPROVAL &
CONFIRMED INSTALLATION OF ANY INSTALLATION VARIATIONS FROM APPROVED INITIAL
AND/OR REVISED PERMIT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR THE
PRODUCTION OF AS-BUILT DOCUMENTS PRODUCED IN DIGITAL AND PDF FORMS. THE
PROJECT ENGINEER OF RECORD IS NOT RESPONSIBLE FOR THE REVIEW AND ACCURACY OF
THE AS-BUILT DRAWINGS, UNLESS A CHANGE ORDER FROM THE CONTRACTOR IS ISSUED
TO THE PROJECT ENGINEER OF RECORD AND COMPANY FOR VERIFICATION.
B. POST INITIAL PERMIT REQUIREMENTS, COMPLIANCE REPORTS, ADDITIONAL
DOCUMENTATION,ETC.PER FBC (2023) ENERGY CONSERVATION, CHAPTER 4, SECTION C407
TOTAL BUILDING PERFORMANCE, THAT MAY BE REQUIRED BY THE AUTHORITY HAVING
JURISDICTION AS A PREREQUISITE FOR A CERTIFICATE OF OCCUPANCY AND/OR CERTIFICATE
OF COMPLETION
41 - SUBMISSION OF BID
CONTRACTOR SUBMISSION OF BID PROPOSAL ACKNOWLEDGES THAT THE PROJECT ENGINEER'S OF RECORD AND COMPANY FOR THE INITIAL PERMIT ARE NOT OBLIGED TO PARTICIPATE IN ANY POST INITIAL PERMIT CERTIFICATE OF OCCUPANCY AND/OR CERTIFICATE OF COMPLETION REQUIREMENTS.
42 - RESTORATION TO EXISTING CONDITIONS
CONTRACTOR SHALL BE RESPONSIBLE TO RESTORE ALL CEILINGS, WALLS, FLOORS, ETC. TO MATCH EXISTING CONDITIONS IN ALL AREAS AFFECTED BY THE ELECTRICAL WORK. CONTRACTOR SHALL
PROVIDE ALL REPAIRS AS REQUIRED AS PART OF THE CONTRACT.
43 - GENERATOR
CONTRACTOR SHALL BE RESPONSIBLE FOR THE EMERGENCY SYSTEM INSTALLATION PER NEC ART.
700, INCLUDING BUT NOT LIMITED TO TESTING, OVERCURRENT PROTECTION, SELECTIVE
COORDINATION STUDY, ETC. SELECTIVE COORDINATION STUDY SHALL BE PROVIDED AS PART OF THE SHOP DRAWINGS REVIEW PRIOR TO ORDER AND PURCHASING OF GENERATOR, AUTOMATIC TRANSFER
SWITCHES, ANNUNCIATOR AND ASSOCIATED EQUIPMENT AND WIRING. GENERATOR SHALL BE
INTERFACE TO THE BUILDING FIRE ALARM SYSTEM AS REQUIRED PER NFPA 70E AND 72, NEC AND
APPLICABLE CODES.
1. REMOVAL OF EXISTING 350KW DIESEL GENERATOR AND BELLY TANK, 1200A SERVICE RATED AUTOMATIC TRANSFER SWITCH, 600A AUTOMATIC TRANSFER SWITCH, ANNUNCIATOR, AND ASSOCIATED
WIRING.
2. INSTALL PROPOSED DIESEL GENERATOR WITH BELLY TANK, AUTOMATIC TRANSFER SWITCHES, ANNUNCIATOR AND ASSOCIATED WIRING. GENERATOR, FUEL TANK, ATS'S, ANNUNCIATOR AND
RELATED ACCESSORIES ARE PURCHASED BY THE CITY. CONTRACTOR IS RESPONSIBLE FOR
THE COORDINATION OF GENERATOR SYSTEM DELIVERY TO JOB SITE WITH MANUFACTURER
VENDOR.
3. MODIFY EXISTING ELECTRICAL FEEDERS TO ACCOMMODATE PROPOSED AUTOMATIC TRANSFER SWITCHES
AS INDICATED HEREIN.
4. FURNISH AND INSTALL ALL THE REQUIRED CHANGES TO THE EXISTING ELECTRICAL SYSTEM AS INDICATED HEREIN. THE ELECTRICAL SYSTEM SHALL BE FULLY OPERATIONAL, INSTALLED PER NEC AND
APPLICABLE CODES.
5. CONTRACTOR SHALL PROVIDE A 200KW TEMPORARY GENERATOR TO PROVIDE EMERGENCY POWER TO THE BUILDING DURING CONSTRUCTION WHILE THE NEW GENERATOR IS SET IN PLACE AND FULLY
OPERATIONAL. CONTRACTOR SHALL PROVIDE ALL REQUIRED CONNECTIONS AND HARDWARE.
SCOPE OF WORK:
ELECTRICAL NOTES
BID SET
NOT FOR CONSTRUCTION
DANIA BEACH CITY HALL WIND PROTECTION
DANIA BEACH, FLORIDA
NONO DATE REVISION BY REVISIONDATE BY
SCALE
PROJECT No
SHEET
DATE:Fi le
N am e:
P :\P ro je ct s\
\2
D an ia B ea ch
E ng in ee rin g
S er vi ce s\
.1 D an ia
B ea ch W in d
P ro te ct io n
A nd
B ac ku p
P ow er T o C ity H al l\c ad d
Fi le s\ D ra w in gs
\2
-E -N
O
TE
.d w g
P lo tte d by
M au ric io G om ez o n Th ur sd ay , A pr il
, 2
1:
:4
P M
JORGE R. CERVANTES, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 45832.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JORGE R. CERVANTES, P.E. ON
THE DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
R
KNOW WHAT'S BELOW
A L WA Y S C A L L 8 1 1
B E F O R E Y O U D I G
It's fast. It's free. It's the law.
www.callsunshine.com
04/21/2026 2259171
AS SHOWN E1
COMMUNITY LIBRARY
FLOOR ELEVATION = 11.42'(NAVD88)
BUS STOP
C O
VE
R
ED
C
O N
C R
ET
E
C O
N C
R E
TE
S
ID
E
W A
LK
CONC.
CONC.
17.4'
22.4'
25.0'
.5
.7
.1
16.3'
A /C
A /C6'
C B
S W
A
LL
GATE
CONC.
LOT 8 LOT 7 LOT 6 LOT 5
LOT 4
LOT 34 STORY
PARKING GARAGE BUILDING
CONCRETE SIDEWALK
C O
N C
. W A
LK
BRICK DRIVE
BRICK DRIVE
BLDG. OVERHANG
LOT 9
11.29 11.35
.3711.4411.49
11.39
11.
11.
10.
10.98
.89
11.
4011.
.15
11.
WV
.43
11.66
10.94
10.
10.85
11.
11.
11.
10.6810.
10.
11.
11.
11.
11.
.41
10.
11.
11.
9.9
11.26 11 .38
11.
11.39
11.
11.46
11.
11.31
11.09
DD
S
D
DDD
11.18
10.98
.46
.50
.49 11 .4
11.39 11.40
.4
11.
11.20 11.
.3
.3
911.36
11.22
11.80
11.89
11.94
11.40
11.32
.05 10.93 10.90
10.85
10.
D
.3
10.
10.67
11.00 10.91
10.88
10.93 11
.0
.24 11.24
.08
10.
10.
10.
10.
11.0611 .03
.29
11.
11.
14 11.28
11.
11.
11.
11.
.00
11.95
11.
11.
11.34
.33
.25
11.
37 11.
11.
11.
11.50
.5
CONC.
C O
N C
DU
MP
ST
ER
P A
D
CONCRETE SIDEWALK
CONC.
C O
N C
R
ET
E
CONCRETE
C O
N C
C U
R B
C O
N C
A/C'S
TRANSFORMER
PAD
M E
TA
L
S
TE
P S
C O
N C
R
ET
E G
EN
ER
AT
O
R P
A D
A/C'S
ASPHALT PARKING
A S
P H
A
LT
P A
R K
IN
G
C O
N C
R
ET
E
SI
D
EW
AL
K
CONC
STEP
FOUND NAIL
LS 3487
ORIGINAL BLOCK LINE
5/ 8"
F C
IR
L B
EDGE OF PAVEMENT
LOT 9 BLOCK 21LOT 8 BLOCK 21LOT 7 BLOCK 21 LOT 6 BLOCK 21LOT 5 BLOCK 21LOT 4 BLOCK 21LOT 3 BLOCK 21 LOT 2 BLOCK 21
FIR (5/8")
LB 3487
4' C
O N
C R
E
TE
W A
LK
4' C
O N
C R
E
TE
W A
LK
E D
G E
O F
P A
V E
M E
N T
E D
G E
O F
P A
V E
M E
N T
E D
G E
O F
P A
V E
M E
N T
M
CONCRETE SIDEWALK
ASPH.
EDGE OF PAVEMENT
ASPH.
CONC.
R
AM
P
WOOD
GATES
2' CURB & GUTTER
9.91
9.70 10.01 9.76
S
9.9010.11 9.7910.02 9.87 9.849.
809.
WV
S
H Y D
WV
WV
9.80
9.7
9.79
9.73 9.73
9.88 9.97
9.98 10.00 9.97
10.10
GRASS
GRASS
COV. BUS BENCH
BIKE RACK CONC.
ASPH.
2' CURB & GUTTER
CONCRETE SIDEWALK
CONC. MON.
CONC. MON.
2' CURB & GUTTER
CONCRETE SIDEWALK
FOUNTAIN
N O
P A
R K
IN
G
R A
M P
C O
V E
R E
D C
O N
C
10.
10.
22 9.49 9.4
9.4 7 9.9
10.
9.53
10.01
FOUNTAIN
E
GRASS
CONC.
GRASS
GRASS
GRASS
CONCRETE
GRASS
GRASS
CONC.
CONC.
METAL STAIRS
CONC.
CONC. CONC.
CONC. SIDEWALK
HEDGE
P
LA
N
TE
R
CONC.
GRASS
GRASS
GRASS
GRASS
GRASS
GRASS
EDGE OF PAVEMENT
CONC.
SET PRM
SET PRM
SET PRM
S88°06'37"W 361.17'
N88°06'37"E
N
°3 7'
"E 30
9.
C L
CL
S88°06'37"W
.0
' F P
L E
A S
E M
E N
T O
.R .B
.4
, P
G .1
4, B .C
.R
8.0'x40.0'
SIDEWALK EASEMENT
P.B. 179, PG. 138, B.C.R.
6.0'x15.0'
BUS SHELTER EASEMENT
P.B. 179, PG. 138, B.C.R.FND NAIL &
DISK LB 514
5.14'ONLINE
W. DANIA BEACH BOULEVARD
(PLATTED AS COCOANUT AVENUE)
50.0' RIGHT-OF-WAY (P.B. B, PG. 49, D.C.R.)
.0
.0
PARCEL 'B'
DANIA BEACH CITY CENTER
P.B. 179, PG. 137, B.C.R.
2.84 ACRES
P.B. 179, PG. 138, B.C.R.
6.0'x24.0'
BUS SHELTER EASEMENT
P.B. 179, PG. 138, B.C.R.
10.0'
10.0' FPL EASEMENT
O.R.B.47146, PG.1014, B.C.R.1
.0
C O
N C
. W A
LK
CONC. WALK
SOUTH LINE PARCEL 'B'
BLOCK 21
MAP OF
THE TOWN OF MODELO
P.B. B, PG. 49, M.D.C.R.
AREA (LOTS 1-9) 1.62 ACRES
4.
4.
T O
T A
L)
4.
T O
T A
L)
N .W
. 3 R
D A
V E
N U
E (P
LA
TT
E D
A S
D A
N
IA
A V
E N
U E
.0 ' R
IG
H
T -O
F -W
A Y
P
.B . B
, P G
. 4 9, M .D
.C .R
WV
9.87
9.9
9.689.51
WV
WV
9.8
9.84
9.59
9.759.74
9.75
9.73
W V
9.87
9.8
.09
S
TEL
S
E
COVERED BUS BENCH
A S
P H
G R
AS
S
C O
N C
R
ET
E
SI
D
EW
AL
K
EL
EC
M
H Y D
10.11
10.36 10.47
M
NORTH LINE BLOCK 21
R E
TE
N
TI
O
N A
R E
A
CONC. WALK
ASPHALT PARKING
C O
N C
R
ET
E
SI
D
EW
AL
K
C O
N C
. W A
LK
EDGE OF PAVEMENT
EDGE OF PAVEMENT
G R
AS
S
G R
AS
S
G R
AS
S
CONC. CURB
20.00'
20.00'
R A
M P
STEP STEP
GRASS
C L
PB
ELECTRICAL SITE PLAN
BID SET
NOT FOR CONSTRUCTION
DANIA BEACH CITY HALL WIND PROTECTION
DANIA BEACH, FLORIDA
( IN FEET )
GRAPHIC SCALE
10 4020
1" = 20'
NONO DATE REVISION BY REVISIONDATE BY
SCALE
PROJECT No
SHEET
DATE:Fi le
N am e:
P :\P ro je ct s\
\2
D an ia B ea ch
E ng in ee rin g
S er vi ce s\
.1 D an ia
B ea ch W in d
P ro te ct io n
A nd
B ac ku p
P ow er T o C ity H al l\c ad d
Fi le s\ D ra w in gs
\2
-E -S
IT
E
-P
LA
N .d w g
P lo tte d by
M au ric io
G om ez o n
Th ur sd ay
, A pr il
, 2
:5 9:
A
M
JORGE R. CERVANTES, STATE OF FLORIDA, PROFESSIONAL ENGINEER, LICENSE NO. 45832.
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY JORGE R. CERVANTES, P.E. ON
THE DATE INDICATED HERE.
PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
R
KNOW WHAT'S BELOW
A L WA Y S C A L L 8 1 1
B E F O R E Y O U D I G
It's fast. It's free. It's the law.
www.callsunshine.com
04/21/2026 2259171
AS SHOWN E2
PLAN NOTES:
1. EXISTING (2)3"C WITH (4)350MCM AND #2GND IN EACH ,
AND 3/4"C FOR GENERATOR STARTER CIRCUIT. ROUTING AND
LOCATION SHOWN ARE PER AS-BUILT DOCUMENTS,
CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY EXISTING
ROUTING AND LOCATION.
2. INTERCEPT EXISTING FEEDER AND PROVIDE NEW 24x24x18D
TRAFFIC RATED PULL BOX. CONTRACTOR SHALL REUSE
EXISTING FEEDER WIRE IF POSSIBLE. PROVIDE ALTERNATE BID
FOR THE FEEDER WIRE REPLACEMENT.
3. PROPOSED 400KW GENERATOR PURCHASED BY THE CITY,
INSTALLED BY CONTRACTOR, AT SAME LOCATION OF PREVIOUS
GENERATOR. REFER TO GENERATOR ENCLOSURE PLAN
DRAWING FOR ADDITIONAL DETAILS.
4. PROVIDE NEW (2)3"C WITH (4)350MCM AND #2GND IN EACH.
5. LOCATION MAIN ELECTRICAL ROOM. REFER TO EXISTING MAIN
ELECTRICAL PLAN FOR ADDITIONAL DETAILS.
6. PROPOSED LOCATION OF NEW GENERATOR ANNUNCIATOR
PANEL PURCHASED BY THE CITY, INSTALLED BY CONTRACTOR
IN MAIN OFFICE AT SAME LOCATION OF PREVIOUS GENERATOR
ANNUNCIATOR PANEL. VERIFY EXACT LOCATION DURING BID.
7. EXISTING PAD MOUNTED FPL TRANSFORMER WITH 120/208V
3-PHASE 4-WIRE ELECTRICAL SERVICE. THIS TRANSFORMER
SERVES THE SERVICE RATED ATS#1 LOCATED IN MAIN
ELECTRICAL ROOM.
8. EXISTING POLE MOUNTED FPL TRANSFORMER WITH 120/208V
3-PHASE 4-WIRE ELECTRICAL SERVICE. THIS TRANSFORMER
SERVES MAIN #2 LOCATED IN GENERATOR COMPOUND AREA.
9. THE CONTRACTOR MUST VERIFY LOCATIONS AND DEPTH OF
ALL UNDERGROUND…