2026-11-09 AGCS - Admininistration - Bid Issue - Architectural.pdf

PDF 9 MB Posted

Attached to
AGCS - State Road - Administration Renovation 26-004
Solicitation number
US.261299
Issued by
Chester County, Pennsylvania

About this file

Architectural Bid Issue Document Summary

This file is a comprehensive architectural bid package for the State Road Administration Renovation Project at Avon Grove Charter School, located at 110 E State Road, West Grove, PA 19390, prepared by Heckendorn Shiles Architects and issued November 10, 2026 for a mandatory pre-bid conference on November 20, 2026 at 3:30 PM. The project scope encompasses exterior canopy demolition and new construction, facade and window replacement, roof repair and membrane replacement, comprehensive interior demolition and renovation of the administration suite including the vestibule, reception areas, offices, restrooms, storage areas, and corridors. The work includes new partition walls, flooring transitions, ceiling systems, interior signage, casework and built-in millwork, new storefront systems with insulated glazing, exterior metal wall panels, roofing systems with new drains and overflow provisions, and coordination of mechanical, electrical, and plumbing penetrations. The project is divided into two phases to minimize disruption to ongoing school operations, with Phase 1 encompassing the majority of interior work and Phase 2 addressing canopy demolition and exterior concrete work. Sealed electronic bids will be accepted via PennBid until 2:30 PM on Tuesday, December 15, 2026, with public opening at 3:00 PM at the school site.

The project is subject to the Pennsylvania Prevailing Wage Act, requiring all prime bidders to register on PennBid and attendance at the mandatory pre-bid conference. Four separate prime contracts are being bid: General Construction (Contract 1), Mechanical (Contract 2), Electrical (Contract 3), and Plumbing (Contract 4). Bidding documents became available free on PennBid starting November 10, 2026, with all addenda and bid notifications posted to the platform. The general contractor bears responsibility for temporary shoring, bracing, all demolition coordination, protection of existing conditions to remain, roof penetrations, finishing of affected surfaces, and coordination with multiple prime contractors. The architectural drawings specify extensive coordination requirements among trades, including MEP (mechanical/electrical/plumbing) and structural work, detailed in the M, P, E, and S series drawings. The project requires corporate surety security equal to a specified percentage of the bid amount, with final award and contract execution anticipated following the December 15, 2026 bid opening.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ARCHITECTURAL

Heckendorn Shiles Architects 347 East Conestoga Road Wayne, PA 19087 610-994-3500

CLIENT

H E

C K

E N

D O

R N

S H

IL

E

S A

R C

H

IT

E C

T S e xp re s s ly r e s e rv e s i ts c o m m o n l a w c o p y ri g h t a n d o th e r p ro p e rt y r ig h ts i n t h e s e p la n s T h e s e a re n o t to b e r e p ro d u c e d n o r a re t h e y t o b e a s s ig n e d t o a n y t h ir d p a rt y w it h o u t fi rs t o b ta in in g t h e e xp re s s e d w ri tt e n c o n s e n t o f H

E C

K E

N D

O R

N S

H

IL

E S

A R

C H

IT

E

C T

S

/1

/2

:5

:4

P M

AGCS STATE ROAD ADMINISTRATION

110 E State Rd, West Grove, PA 19390

11-09-2026: BID ISSUE

Orndorf & Associates, Inc 8600 West Chester Pike, Suite 201 Upper Darby, PA 19802

STRUCTURAL

Avon Grove Charter School 110 E State Rd West Grove, PA 19390 484-667-5000

Schiller & Hersh Associates, Inc.

636 Skippack Pike, Suite 200 Blue Bell, PA 19422 215-886-8947

MEPFP

E

ROOM NAME

XXX

101B

AXXX

WP

XXXX

XX

100.5'

ROOM IDENTIFICATION

DOOR IDENTIFICATION

ENLARGED PLAN OR DETAIL

MARK

MULTIPLE ELEVATION

REFERENCE

ELEVATION REFERENCE

SECTION REFERENCE

WORKING POINT OR

DATUM

PARTITION TYPE

COLUMN GRID

NORTH ARROW

SPOT ELEVATION TAG

FINISH TAG

EQUIPMENT TAG

XXX

FINISH FLOOR ELEVATION

TAG

WINDOW TAG

ARCHITECTURAL LEGEND

1 AXXX

XX

EXISTING CONSTRUCTION

DEMOLISH;

REMOVE CONSTRUCTION

NEW CONSTRUCTION

REMOVE DOOR, FRAME,

& HARDWARE

SOFFIT, OPEN

ABOVE

BUILT-IN CASEWORK

P-1

AXXX

SIM

PLAN

NORTH

1. THESE DRAWINGS ARE MEANT TO OUTLINE GENERAL SCOPE OF

DEMOLITION FOR THE CONTRACTOR. THE SPECIFIC AREAS, ITEMS, DETAILS,

MATERIALS, ETC. OF DEMOLITION WILL BE A RESULT OF FIELD CONDITIONS.

THE INTENT IS THAT ALL DEMOLITION REQUIRED TO PROPERLY CONSTRUCT

THIS PROJECT IS THE RESPONSIBILITY OF THE PRIME CONTRACTOR. THE

CONTRACTOR WILL INSURE THAT THE EXIST. BUILDING RETAINS STRUCTURAL

INTEGRITY AND REMAINS WATER AND WEATHER-TIGHT DURING THE

DEMOLITION AND CONSTRUCTION PHASES OF THE WORK.

2. CONTRACTOR MUST REVIEW NEW WORK INDICATED IN 'A' SERIES DRAWINGS

AND COORDINATE DEMOLITION WORK WITH NEW WORK.

3. CONTRACTOR MUST COORDINATE ALL ARCHITECTURAL DEMOLITION WITH

MECHANICAL/ELECTRICAL/PLUMBING DEMOLITION WORK AS SHOWN ON

'M', 'P', 'E' SERIES DRAWINGS. THE PRIME CONTRACTORS WILL BE RESPONSIBLE

FOR THE CONTINUOUS INTERNAL UTILITIES DISTRIBUTION INCLUDING BUT

NOT LIMITED TO THE WATER & ELECTRICAL DISTRIBUTION SYSTEMS.

4. CONTRACTOR MUST COORDINATE ALL ARCHITECTURAL DEMOLITION WITH

STRUCTURAL DEMOLITION WORK AS SHOWN ON 'S' SERIES DRAWINGS.

5. CONTRACTOR MUST COORDINATE COURSE OF DEMOLITION WORK WITH

OVERALL CONSTRUCTION SCHEDULE.

6. CAREFULLY COORDINATE ALL DEMOLITION WORK WITH EXIST.

CONSTRUCTION TO REMAIN. ANY EXIST. CONSTRUCTION TO REMAIN THAT

IS DAMAGED BY DEMOLITION SHALL BE REPAIRED/REPLACED TO MATCH

ORIGINAL CONDITION. SEE SPECIFICATIONS FOR CLARIFICATION OF

RESPONSIBILITY.

7. GENERAL CONTRACTOR IS RESPONSIBLE TO PATCH/REPAIR ALL FINISH

SURFACES AFFECTED BY DEMOLITION WORK. SEE THE GENERAL

REQUIREMENTS SECTIONS OF THE SPECIFICATION.

8. GENERAL CONTRACTOR SHALL COORDINATE, PRIOR TO ANY DEMOLITION,

WHAT MATERIALS OR ITEMS OF EQUIPMENT ARE TO BE RETAINED BY THE

OWNER. ALL OTHER DISMANTLED MATERIALS SHALL BECOME THE PROPERTY

OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE PREMISES

ACCORDING TO ALL APPLICABLE CODES.

9. CARE SHOULD BE TAKEN TO AVOID DISTURBING ANY SYSTEM LINES WHICH

ARE TO REMAIN. PRIOR TO THE START OF CONSTRUCTION, GENERAL

CONTRACTOR MUST COORDINATE W/ ELECTRICAL CONTRACTOR WHICH

LINES ARE TO REMAIN IN SERVICE.

10. GENERAL CONTRACTOR MUST CAREFULLY COORDINATE DEMOLITION OF

EXTERIOR WALLS WITH THE INTENT OF THE NEW CONSTRUCTION. ALL

FOOTINGS AND STRUCTURAL MEMBERS SHALL REMAIN INTACT, UNLESS

NOTED OTHERWISE. CONTRACTOR TO COORDINATE W/ STRUCTURAL

DWGS.

11. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

12. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL TEMPORARY SHORING

AND BRACING OF STRUCTURE PRIOR TO AND DURING DEMOLITION AND

NEW CONSTRUCTION.

13. WHERE WALLS ARE INDICATED TO BE REMOVED, CONTRACTOR MUST FIELD

VERIFY IF THE WALLS ARE STRUCTURAL BEARING WALLS. IF IT IS DETERMINED

THAT THE WALLS TO BE REMOVED ARE BEARING, THE CONTRACTOR IS

RESPONSIBLE TO PROVIDE TEMPORARY SUPPORT AT AREAS WHERE WALLS ARE

TO BE REMOVED. IF THE CONTRACTOR CANNOT DETERMINE IF THE WALL IS

BEARING, THE CONTRACTOR MUST CONTACT THE PROJECT STRUCTURAL

ENGINEER FOR CLARIFICATION PRIOR TO COMMENCING WORK.

DEMOLITION GENERAL NOTES

1. ALL DRAWINGS ARE TO BE USED IN CONJUNCTION WITH SPECIFICATIONS IN

DETERMINING THE FULL PROJECT SCOPE.

2. REFER TO MEP DWGS FOR MECHANICAL, ELECTRICAL, PLUMBING WORK.

3. REFER TO STRUCTURAL DWGS FOR STRUCTURAL WORK.

4. DO NOT SCALE DRAWINGS: WRITTEN DIMENSIONS GOVERN PARTITION

LOCATIONS, DIMENSIONS AND TYPES. IN CASE OF CONFLICT, NOTIFY

ARCHITECT FOR WRITTEN CLARIFICATIONS PRIOR TO PROCEEDING W/

CONSTRUCTION. CONSTRUCTION PLAN BY ARCHITECT SUPERCEDES OTHER

PLANS.

5. DIMENSIONS MARKED "CLEAR" OR "CLR" SHALL BE MAINTAINED AND SHALL

ALLOW FOR THICKNESS OF FINISHES INCLUDING CARPET, VCT, ETC.

CONTRACTOR SHALL NOT ADJUST DIMENSIONS WITHOUT WRITTEN

INSTRUCTIONS FROM THE ARCHITECT.

6. DIMENSIONS SHOWN AS "VIF" SHALL BE VERIFIED BY THE CONTRACTOR IN

THE FIELD BY LAYING OUT THE PARTITIONS. CONTRACTOR SHALL NOTIFY

ARCHITECT OF ANY DISCREPANCY IN DIMENSIONS PRIOR TO PROCEEDING

WITH THE WORK IN THE AREA.

7. PARTITION CONSTRUCTION SHALL COMMENCE ONLY AFTER THE ARCHITECT

HAS REVIEWED LAYOUT.

8. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND JOB CONDITIONS PRIOR

TO STARTING WORK AND SHALL REPORT TO THE ARCHITECT ANY

DISCREPANCIES OR OMISSIONS WHICH WOULD INTERFERE WITH

SATISFACTORY COMPLETION OF WORK.

9. ALL BUILDING DEPARTMENT PERMITS SHALL BE OBTAINED PRIOR TO

COMMENCEMENT OF WORK.

10. PROVIDE PORTABLE FIRE EXTINGUISHERS IN COMPLIANCE WITH

INTERNATIONAL FIRE CODE SECTION 906

11. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

12. PENETRATIONS IN ROOF/ROOF MEMBRANE TO BE COMPLETED BY GC

ONLY. GC TO COORDINATE ALL OF PENETRATIONS WITH OTHER PRIMES

AND PROVIDE ROOF REPAIRS/ INSTALLATION AS REQUIRED. MC TO PROVIDE

CURBS FOR INSTALLATION. GC TO PROVIDE PT WOOD BLOCKING AS

REQUIRED FOR LEVEL INSTALLATION.

13. ALL WORK TO BE COMPLETED IN A MANNER TO ENSURE THE EXISTING

ROOF WARRANTY IS MAINTAINED.

14. THE SCHOOL DATA VENDOR WILL BE ONSITE TO DEMOLISH AND REPLACE

DATA CABLING DURING DEMOLITION AS REQUIRED GC TO COORDINATE TO

PROVIDE ACCESS AND TO COORDINATE EFFORTS.

15. THE SCHOOL HAS BEEN MADE AWARE THAT THERE IS ASBESTOS

CONTAINING MATERIAL ONSITE. IT IS LIKELY TO BE ENCOUNTERED AT THE

EXTERIOR WINDOWS AND IN-WALL PIPE INSULATION. SCHOOL WILL TEST

AND ANY ABATEMENT REQUIRED WILL BE ADDRESSED BY THE SCHOOL.

CONSTRUCTION GENERAL NOTES

STEEL

BRICK WOOD FRAMING,

CONTINUOUS

EARTH,

UNDISTURBED

CRUSHED ROCK

GRAVEL

PLASTER OR

GYPSUM BOARD

(SECTION OR

ELEVATION)

PARTICLE BOARD

WOOD BLOCKING

OR SHIM

RIGID INSULATION

CONCRETE

MASONRY

CONCRETE,

CAST STONE (SECTION

OR ELEVATION)

EARTH, COMPACTED

FILL

PLYWOOD

SOLID SURFACE

SOLID WOOD

(SECTION OR

ELEVATION)

STONE

(MARBLE/GRANITE)

MATERIALS LEGEND (VIEWED IN SECTION)

WP

2X2 SURFACE LIGHT FIXTURE

2X4 SURFACE LIGHT FIXTURE

1X4 SURFACE LIGHT FIXTURE

SURFACE MOUNTED

2X2 RECESSED LIGHT FIXTURE

2X4 RECESSED LIGHT FIXTURE

1X4 RECESSED LIGHT FIXTURE

CEILING HEIGHT

GWB SOFFIT OR CEILING

SUPPLY AIR DIFFUSER

RETURN AIR DIFFUSER

LINEAR SLOT DIFFUSER

CEILING MOUNTED SMOKE DETECTOR

FIRE ALARM SPEAKERS

SPRINKLER HEAD

WALL MOUNTED EMERGENCY LIGHTING

TRACK LIGHTING FIXTURE

SUSPENSION GRID & 2' X 2' LAY-IN

ACOUSTIC CEILING TILE

DIRECTIONAL SUPPLY AIR DIFFUSER

RECESSED DOWNLIGHT

WALL SCONCE

PENDANT MOUNTED LINEAR

START OF CONSTRUCTION/CEILING WORK POINT

PA SPEAKER

EXIT SIGN - CEILING MOUNTED

ILLUMINATED SINGLE & DOUBLE FACE

DIRECTIONAL ARROWS AS INDICATED

EXIT SIGN - WALL MOUNTED

ILLUMINATED SINGLE & DOUBLE FACE

DIRECTIONAL ARROWS AS INDICATED

4' SURFACE MOUNT LINEAR LIGHT FIXTURE

CEILING LEGEND

SD

FA

S

SUSPENSION GRID & 2' X 4' LAY-IN

ACOUSTIC CEILING TILE

0' - 0"

ABC-1 CEILING TYPE

WALL MTD. DUPLEX RECEPTACLE OUTLET

GFI = GROUND FAULT INTERRUPTER

WALL MTD. DUPLEX RECEPTACLE OUTLET W/

UNINTERRUPTED POWER SOURCE

WALL MTD. QUADRUPLEX RECEPTACLE

WALL MTD. DEDICATED DUPLEX RECEPTACLE OUTLET

WALL MTD. TEL. OUTLET

WALL MTD. DATA OUTLET

WALL MTD. COMBINATION TELEPHONE AND DATA

OUTLET

COMBINATION POWER, TELEPHONE AND

DATA FLOOR OUTLET (FLUSH MOUNTED)

FIRE ALARM SPEAKER

PA SPEAKER

FIRE WARDEN STATION

MANUAL FIRE ALARM PULL STATION (SEE MTG.

HEIGHT SCHEDULE)

WALL MOUNTED STROBE

HOLD OPEN

MAGNETIC LOCK (SEE HARDWARE SCHEDULE)

STATIONARY SECURITY CAMERA

ZOOM, PAN, TILT SECURITY CAMERA

ELECTRIC LOCKSET (SEE HARDWARE SCHEDULE)

ELECTRIC STRIKE (SEE HARDWARE SCHEDULE)

MOTION DETECTOR

DOOR CONTACTS

CARD READER

TELEVISION OUTLET

THRU-WALL POWER/COMMUNICATIONS

INFEED

2 DATA / 2 PHONE JACKS (WALL MOUNTED

OR BASE FEED)

POWER AND COMM. LEGEND

OUTLETS

FIRE ALARM AND SAFETY

SWITCHES

ELECTRONIC HARDWARE

SIGNAL SYSTEMS

G F I

T V

2 2

FW

F

S

MD

H

ML

EL

ES

DC

CR

ZPT

FA

WALL MTD. QUADRUPLEX RECEPTACLE OUTLET

GFI = GROUND FAULT INTERRUPTER

G F I

WALL MTD. DUPLEX RECEPTACLE OUTLET

EQUIPMENT ITEM - SEE SCHEDULE

FEC (FIRE EXTINGUISHER CABINET)

FE (FIRE EXTINGUISHER - WALL MOUNTED)

FEC

FE

COMBINATION HORN & STROBEH/S

ALTERNATE SYMBOLS SELECTION:

COORDINATE WITH PROJECT MEP ENGINEER'S SYMBOLS

JUNCTION BOX

S

J

P/C

J

ALTERNATE 1:

BASE SCOPE: CEILING GRID AND LIGHT FIXTURES IN CORRIDOR TO REMAIN. NEW ACOUSTIC CEILING

TILE TO BE PROVIDED.

ALTERNATE SCOPE: CEILING GRID AND LIGHT FIXTURES IN CORRIDOR TO BE REMOVED AND NEW

CEILING GRID, TILES AND LIGHTS TO BE PROVIDED.

ALTERNATE 2:

BASE SCOPE: NO BOLLARDS TO BE PROVIDED INSTALLED.

ALTERNATE SCOPE: PROVIDE BOLLARDS AS INDICATED ON PLAN IN EXISTING SIDEWALK.

ALTERNATES

DATE ISSUED FOR

H E

C K

E N

D O

R N

S H

IL

E

S A

R C

H

IT

E C

T S e xp re s s ly r e s e rv e s i ts c o m m o n l a w c o p y ri g h t a n d o th e r p ro p e rt y r ig h ts i n t h e s e p la n s T h e s e a re n o t to b e r e p ro d u c e d n o r a re t h e y t o b e a s s ig n e d t o a n y t h ir d p a rt y w it h o u t fi rs t o b ta in in g t h e e xp re s s e d w ri tt e n c o n s e n t o f H

E C

K E

N D

O R

N S

H

IL

E S

A R

C H

IT

E

C T

S

CLIENT

DRAWING NUMBER

SHEET TITLE

ISSUE HISTORY

PROJECT TEAM

ARCHITECTURAL

Heckendorn Shiles Architects 347 East Conestoga Road Wayne, PA 19087 610-994-3500

NOT FOR

CONSTRUCTION

/1 /2

:5

:4

P M

A001

DRAWING LIST,

LEGENDS,

ABBREVIATIONS

AGCS STATE ROAD

ADMINISTRATION

110 E State Rd, West Grove, PA 19390

HSA PROJECT # :26-004

Avon Grove Charter School 110 E State Rd West Grove, PA 19390 484-667-5000

Orndorf & Associates, Inc 8600 West Chester Pike, Suite Upper Darby, PA 19802

STRUCTURAL

Schiller & Hersh Associates, Inc.

636 Skippack Pike, Suite 200 Blue Bell, PA 19422 215-886-8947

MEPFP

DRAWING LIST

NUMBER SHEET NAME 1

-0

-2

B

ID

I S S U

E

A000 COVER SHEET X

A001 DRAWING LIST, LEGENDS, ABBREVIATIONS X

A002 CODE ABSTRACT / INTERIOR SIGNAGE PLAN X

A003 PHASING/ STAGING PLANS X

A004 EXISTING PHOTOGRAPHS X

A005 EXISTING PHOTOGRAPHS X

AD101 EXISTING CONDITIONS & DEMOLITION - FIRST FLOOR PLAN X

AD102 EXISTING CONDITIONS & DEMOLITION - ROOF PLAN X

AD110 EXISTING CONDITIONS & DEMOLITION - FIRST FLOOR RCP X

AD200 EXISTING CONDITIONS & DEMO - EXT. ELEV'S AND SECTIONS X

AD300 EXISTING CONDITIONS & DEMOLITION - BUILDING SECTIONS X

A101 NEW CONSTRUCTION PLAN X

A102 NEW CONSTRUCTION ROOF PLAN X

A110 NEW CONSTRUCTION REFLECTED CEILING PLAN X

A120 NEW CONSTRUCTION FINISH PLAN X

A130 NEW CONSTRUCTION FFE PLAN X

A200 NEW CONSTRUCTION EXTERIOR ELEVATIONS X

A300 NEW CONSTRUCTION BUILDING SECTIONS X

A310 NEW CONSTRUCTION WALL SECTIONS X

A401 ENLARGED PLAN AND INT. ELEVATIONS - SECTOR B X

A400 ENLARGED PLAN AND INT. ELEVATIONS - SECTOR A X

A402 ENLARGED PLAN & EXTERIOR ELEVATIONS - CANOPY X

A500 DETAILS - TRANSITIONS X

A501 DETAILS - CASEWORK X

A502 DETAILS - GREETER DESK AND MISC. DETAILS X

A503 DETAILS - INTERIOR STOREFRONT, DOORS & COLUMN WRAP X

A504 DETAILS - EXTERIOR WALL & WINDOW X

A506 DETAILS - ROOF X

A505 DETAILS - EXTERIOR WALL & SITE X

A600 PARTITION SCHEDULE & DETAILS X

A601 SCHEDULES X

DRAWING LIST

1 11-09-2026 BID ISSUE

STRUCTURAL DRAWING LIST

NUMBER SHEET NAME 1

-0

-2

B

ID

I S S U

E

S0.0 STRUCTURAL NOTES X

S1.0 STRUCTURAL PLANS X

S5.0 STRUCTURAL DETAILS X

S5.1 FRAMING DETAILS & SCHEDULES X

REFER TO ENGINEERING COVER SHEETS FOR DRAWING LISTS

FEC

116106

102A 102B

125101A

104103

RS1 RS1

A1

R3

RS1

RS1

RS1

RS2

RS2

RS2

RS2

R3

RS2

RS2

RS2

RS2

GREETER /

RECEPTION

OFFICE

OFFICE

COLLAB.

ADMIN

KITCHENETTE

RR

COPY /

PRINT

MAIL

STORAGE

UTILITY

OFFICE

MOTHER'S

ROOM

RECEPTION

STORAGE

OFFICE

OFFICE

NURSES

STATION

RR

STORAGE

COTS

CORRIDOR

WAITING

RS2

RS2

RS2

E1 E1

E1 E1

NOTES:

1. REFER TO FIXTURE/DEVICE MOUNTING HEIGHT SCHEDULE ON A603 FOR SIGNAGE MOUNTING HEIGHT INFO.

2. ALL SIGNAGE MUST COMPLY W/ ICC/ ANSI A117.1-2017.

3. ALL SIGNAGE MUST COMPLY W/ LIMITS OF PROTRUDING OBJECTS.

4. VISUAL CHARACTERS MUST COMPLY W/ ICC/ ANSI A117.1-2017 SECTION 703.2.

5. ALL SIGNAGE MUST BE TACTILE AND MUST COMPLY W/ ICC/ ANSI A117.1-2017 SECTIONS 703.5

6. SYMBOLS & PICTOGRAMS MUST COMPLY W/ ICC/ ANSI A117.1-2017 703.5 & 703.6

7. TYPICAL SIGN REQUIREMENTS (U.N.O)

A. SIGN SIZE; AS RECOMMENDED BY MFGR AND AS REQUIRED BY CODE U.N.O.

B. MESSAGE PANEL MATERIAL; MFGR STANDARD.

C. MESSAGE PANEL FINISH/COLOR; AS SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL RANGE.

D. BACKGROUND FINISH/ COLOR; AS SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL RANGE.

E. CHARACTER SIZE; 3/8" TYPEFACE, ACCOMPANIED BY GRADE 2 BRAILLE U.N.O.

F. CHARACTER FINISH/ COLOR; AS SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL RANGE.

8. SIGNAGE MOUNTED ON GLASS. PROVIDE BLANK PANEL ADHERED TO OPPOSITE FACE OF GLASS

9. ROOM NAMES AND NUMBERS TO BE CONFIRMED WITH OWENR PRIOR TO MANUFACTURING

10. MOUNTING LOCATIONS TO BE REVIEWED IN FIELD WITH OWNER/ARCHITECT PRIOR TO INSTALLATION.

11. SIGNS TO BE 8.5" WIDE TYPICALLY, UNO. SIGN HEIGHT DEPENDANT ON ROOM TYPE. REFER TO REDMARKS AND

SPECIFICATION FOR ADDITIONAL INFORMATION

12. BASIS OF DESIGN SIGNAGE MANUFACTURER : APCO. REFER TO SPECIFICATION FOR ADDITIONAL INFORMATION.

13. ALL SIGNAGE TO INCLUDE ROOM NUMBER/FIRE REFERENCE NUMBER. SEE SIGNAGE PLAN FOR RELEVANT NUMBER

INFORMATION. SEE ELEVATION ON THIS SHEET FOR NUMBER LOCATION ON SIGNAGE.

INTERIOR ROOM SIGNAGE SCHEDULE

A1

RS2

R3

SIGN TAG SIGN LABEL REMARKS

ADMIN BOD: EVU1-B2

RESTROOM

PROVIDE UNISEX RESTROOM SIGNAGE SHOWING HANDICAP ACCESSIBILITY BOD: EVU1-R3.

ANTICIPATED SIGN SIZE 8-1/2" X 8-9/16"

BOD: EVU1-B2 OR B4, HEIGHT OF SIGN AS REQUIRED TO FIT TEXT AND BRAILLE

RS1

PROVIDE STANDARD ROOM SIGNAGE W/ REMOVABLE NAME SLOT, INCLUDE RM NAME AND SIGNAGE

NUMBER BOD: EVU1-B12

E1 EXIT BOD: EVU1-82. ANTICIPATED SIGN SIZE 8-1/2" X 2-1/2"

DATE ISSUED FOR

H E

C K

E N

D O

R N

S H

IL

E

S A

R C

H

IT

E C

T S e xp re s s ly r e s e rv e s i ts c o m m o n l a w c o p y ri g h t a n d o th e r p ro p e rt y r ig h ts i n t h e s e p la n s T h e s e a re n o t to b e r e p ro d u c e d n o r a re t h e y t o b e a s s ig n e d t o a n y t h ir d p a rt y w it h o u t fi rs t o b ta in in g t h e e xp re s s e d w ri tt e n c o n s e n t o f H

E C

K E

N D

O R

N S

H

IL

E S

A R

C H

IT

E

C T

S

CLIENT

DRAWING NUMBER

SHEET TITLE

KEYPLAN

ISSUE HISTORY

PROJECT TEAM

ARCHITECTURAL

Heckendorn Shiles Architects 347 East Conestoga Road Wayne, PA 19087 610-994-3500

NOT FOR

CONSTRUCTION

OUT OF ARCHITECTURAL SCOPE

SECTOR DESIGNATION

PLAN

NORTH

LEGEND

MISC ITEM AS NEEDED

MISC ITEM AS NEEDED

/1 /2

:5

:4

P M

A002

CODE ABSTRACT /

INTERIOR SIGNAGE

PLAN

AGCS STATE ROAD

ADMINISTRATION

110 E State Rd, West Grove, PA 19390

HSA PROJECT # :26-004

Avon Grove Charter School 110 E State Rd West Grove, PA 19390 484-667-5000

Orndorf & Associates, Inc 8600 West Chester Pike, Suite Upper Darby, PA 19802

STRUCTURAL

Schiller & Hersh Associates, Inc.

636 Skippack Pike, Suite 200 Blue Bell, PA 19422 215-886-8947

MEPFP

1 11-09-2026 BID ISSUE

3/16" = 1'-0"A002

1 SIGNAGE PLAN

12" = 1'-0"A002

2 TACTILE SIGNAGE

WH

G F I

G F I

G F I

FEC

S S

UP

.9

.5

DN

DN

GC TO PROVIDE ACCESS DOOR

WITH PANIC BAR. PROVIDE

SIGNAGE STATING

'CONSTRUCTION ZONE -

EMERGENCY EXIT ONLY'

PROVIDE TEMP WALL WITH PTD GWB ON CORRIDOR

SIDE. FRAMING TO UNDERSIDE OF DECK

M

IN

MAINTAIN EXISTING CORRIDOR WALL FOR ACOUSTIC SEPARATION

UNTIL MASONRY BEARING WALL AND SLAB CUTTING IS COMPLETE

DUMPSTER AND

LAYDOWN - GC TO

PROVIDE SECURITY

FENCING

T R A

F F

IC

F

LO

W I N

P A

R K

IN

G L

O T M

U S T B

E

M

IN

T A

IN

E D

EXISTING ESTATE FENCE

AND GATES

GRASS AVAILABLE AS LAYDOWN AREA ,GC TO PROVIDE FENCING

SURROUNDING TO MAINTAIN SAFETY/SECURITY.

ANY DAMAGE TO GRASS REQUIRES REGRADING AND RESEEDING.

SIDEWALK TO REMAIN FULLY OPEN

CONTRACTOR PARKING

(ADDITIONAL PARKING

'REMOTE' ON SITE MAY BE

AVAILABLE

1. REFER TO SHEET A001 FOR ADDITIONAL DEMOLITION NOTES.

2. THIS PLAN IS MEANT TO OUTLINE THE GENERAL SCOPE OF

STAGING FOR THE CONTRACTORS. THE SPECIFIC AREAS,

ITEMS, DETAILS, EXTENT, ETC. WILL BE A RESULT OF

COORDINATION OF ALL PRIME CONTRACTORS.

3. STAGING PLAN PROVIDED FOR REFERENCE, EXACT LAYOUT TO

BE DETERMINED DURING PRECONSTRUCTION.

4. GC RESPONSIBLE FOR PROVIDING UPDATED STAGING PLAN AS

PART OF PREVONSTRUCTION PHASE

5. GC TO PROVIDE PORTABLE TOILETS FOR THE DURATION OF

THE PROJECT, FINAL LOCATION TO BE VERIFIED WITH OWNER

PRIOR TO ONSITE CONSTRUCTION START

6. GC TO PROVIDE SECURED FENCING AROUND STAGING AREAS

IDENTIFIED.

7. LAYDOWN AREA AND DUMPSTER RESTRICTIONS SHOWN FOR

PHASE 1. ADDITIONAL LAYDOWN AREA IN PARKING LOT CAN

BE AVAILABLE DURING PHASE 2 IF REQUIRED, BUT WILL REQUIRE

FURTHER COORDINATION WITH OWNER.

8. DAMAGE TO GRASS REQUIRES REGRADING AND RESEEDING BY

PRIME THAT CREATED THE DAMAGE.

9. TRAFFIC FLOW THROUGH PARKING LOTS MUST BE

MAINTAINED

10. CRANES/HOISTS - PRIMES RESPONBSIBLE FOR CRANES/HOISTS

AS REQUIRED. PLANS FOR CRANES MUST BE REVIEWED AND

APPROVED BY OWNER. PRIME RESPONSIBLE FOR PROTECTION

OF SITE CONDITIOSN AS WELL AS SAFETY ADN NOTIFICATION

OF TRAFFIC/KIDS. CRANES MUST BE SCHEDULED TO HAVE NO

IMPACT SCHOOL OPERATIONS.

11. TEMPORARY PARTITION TO REMAIN IN PLACE UNTIL PHASE 2.

12. PHASING PROVIDED TO ENSURE SCHOOL OPERATIONS ARE

MINIMALLY IMPACTED. ITEMS NOTED AS PHASE 2 CANNOT

START BEFORE DATES NOTED IN SPECIFICATION, UNLESS

AGREED UPON BY OWNER.

A. PHASE 1 - SCOPE OF PROJECT NOT NOTED IN PHASE 2.

B. PHASE 2 - CANOPY DEMOLITION AND NEW

CONSTRUCTION, EXTERIOR CONCRETE SLAB DEMOLITION

AND NEW CONSTRUCTION, EXTERIOR HANDRAILS

DEMOLITION, ROOF COPING REPLACEMENT, CORRIDOR

CEILING REMOVAL AND REPLACEMENT.

SHEET NOTES

DATE ISSUED FOR

H E

C K

E N

D O

R N

S H

IL

E

S A

R C

H

IT

E C

T S e xp re s s ly r e s e rv e s i ts c o m m o n l a w c o p y ri g h t a n d o th e r p ro p e rt y r ig h ts i n t h e s e p la n s T h e s e a re n o t to b e r e p ro d u c e d n o r a re t h e y t o b e a s s ig n e d t o a n y t h ir d p a rt y w it h o u t fi rs t o b ta in in g t h e e xp re s s e d w ri tt e n c o n s e n t o f H

E C

K E

N D

O R

N S

H

IL

E S

A R

C H

IT

E

C T

S

CLIENT

DRAWING NUMBER

SHEET TITLE

KEYPLAN

ISSUE HISTORY

PROJECT TEAM

ARCHITECTURAL

Heckendorn Shiles Architects 347 East Conestoga Road Wayne, PA 19087 610-994-3500

NOT FOR

CONSTRUCTION

OUT OF ARCHITECTURAL SCOPE

SECTOR DESIGNATION

PLAN

NORTH

LEGEND

MISC ITEM AS NEEDED

MISC ITEM AS NEEDED

/1 /2

:5

:4

P M

A003

PHASING/ STAGING

PLANS

AGCS STATE ROAD

ADMINISTRATION

110 E State Rd, West Grove, PA 19390

HSA PROJECT # :26-004

Avon Grove Charter School 110 E State Rd West Grove, PA 19390 484-667-5000

Orndorf & Associates, Inc 8600 West Chester Pike, Suite Upper Darby, PA 19802

STRUCTURAL

Schiller & Hersh Associates, Inc.

636 Skippack Pike, Suite 200 Blue Bell, PA 19422 215-886-8947

MEPFP

1 11-09-2026 BID ISSUE

1/16" = 1'-0"A003

1 SITE STAGING PLAN

DATE ISSUED FOR

H E

C K

E N

D O

R N

S H

IL

E

S A

R C

H

IT

E C

T S e xp re s s ly r e s e rv e s i ts c o m m o n l a w c o p y ri g h t a n d o th e r p ro p e rt y r ig h ts i n t h e s e p la n s T h e s e a re n o t to b e r e p ro d u c e d n o r a re t h e y t o b e a s s ig n e d t o a n y t h ir d p a rt y w it h o u t fi rs t o b ta in in g t h e e xp re s s e d w ri tt e n c o n s e n t o f H

E C

K E

N D

O R

N S

H

IL

E S

A R

C H

IT

E

C T

S

CLIENT

DRAWING NUMBER

SHEET TITLE

ISSUE HISTORY

PROJECT TEAM

ARCHITECTURAL

Heckendorn Shiles Architects 347 East Conestoga Road Wayne, PA 19087 610-994-3500

NOT FOR

CONSTRUCTION

/1 /2

:5

:5

P M

A004

EXISTING

PHOTOGRAPHS

AGCS STATE ROAD

ADMINISTRATION

110 E State Rd, West Grove, PA 19390

HSA PROJECT # :26-004

Avon Grove Charter School 110 E State Rd West Grove, PA 19390 484-667-5000

Orndorf & Associates, Inc 8600 West Chester Pike, Suite Upper Darby, PA 19802

STRUCTURAL

Schiller & Hersh Associates, Inc.

636 Skippack Pike, Suite 200 Blue Bell, PA 19422 215-886-8947

MEPFP

1 11-09-2026 BID ISSUE

1/32" = 1'-0"A004

1 PHOTOGRAPH KEY PLAN1 1/2" = 1'-0"A004

STRUCTURE AT CANOPY FROM RENOVATION IN 2009 - SHOWS EXIST

ROOF DRAIN

1 1/2" = 1'-0"A004

4 STRUCTURE AT CANOPY FROM RENOVATION IN 2009

1 1/2" = 1'-0"A004

2 OVERVIEW IMAGE OF EXSTIGN CANOPY/ENTRANCE

1 1/2" = 1'-0"A004

8 WEST SIDE OF ENTRY WALL

1 1/2" = 1'-0"A004

6 SIDE VIEW OF CANOPY

1 1/2" = 1'-0"A004

5 UNDERSIDE OF CANOPY, ENTRANCE ADN RAMP/STAIRS

1 1/2" = 1'-0"A004

3 ADMINISTRATION BRICK WALL

1 1/2" = 1'-0"A004

9 VIEW FROM ON ROOF OF CANOPY

jared Snapshot jared Snapshot

DATE ISSUED FOR

H E

C K

E N

D O

R N

S H

IL

E

S A

R C

H

IT

E C

T S e xp re s s ly r e s e rv e s i ts c o m m o n l a w c o p y ri g h t a n d o th e r p ro p e rt y r ig h ts i n t h e s e p la n s T h e s e a re n o t to b e r e p ro d u c e d n o r a re t h e y t o b e a s s ig n e d t o a n y t h ir d p a rt y w it h o u t fi rs t o b ta in in g t h e e xp re s s e d w ri tt e n c o n s e n t o f H

E C

K E

N D

O R

N S

H

IL

E S

A R

C H

IT

E

C T

S

CLIENT

DRAWING NUMBER

SHEET TITLE

ISSUE HISTORY

PROJECT TEAM

ARCHITECTURAL

Heckendorn Shiles Architects 347 East Conestoga Road Wayne, PA 19087 610-994-3500

NOT FOR

CONSTRUCTION

/1 /2

:5

:5

P M

A005

EXISTING

PHOTOGRAPHS

AGCS STATE ROAD

ADMINISTRATION

110 E State Rd, West Grove, PA 19390

HSA PROJECT # :26-004

Avon Grove Charter School 110 E State Rd West Grove, PA 19390 484-667-5000

Orndorf & Associates, Inc 8600 West Chester Pike, Suite Upper Darby, PA 19802

STRUCTURAL

Schiller & Hersh Associates, Inc.

636 Skippack Pike, Suite 200 Blue Bell, PA 19422 215-886-8947

MEPFP

1 11-09-2026 BID ISSUE

1/32" = 1'-0"A005

1 PHOTOGRAPH KEY PLAN

1 1/2" = 1'-0"A005

2 CLERESTORY GLAZING AND BRICK RECESSES

1 1/2" = 1'-0"A005

3 BRICK RECESS DEPTH

1 1/2" = 1'-0"A005

4 BRICK RECESS WIDTH

1. REFER TO SHEET A001 FOR ADDITIONAL DEMOLITION

NOTES.

2. REMOVE ALL WALL MOUNTED ITEMS AND ASSOCIATED

HARDWARE WITHIN SCOPE OF WORK UNO. PROTECT FROM

DAMAGE AND COORDINATE REINSTALLATION OF ITEMS

WITH NEW CONSTRUCTION DRAWINGS. WALL MOUNTED

ITEMS INCLUDE BUT IS NOT LIMITED TO:

A. BLINDS

B. ROOM SIGNAGE

C. TOILET ACCESSORIES

D. WHITE BOARDS

E. TACK BOARDS

F. DISPLAY CASES

G. DOOR STOPS

H. SCREWS,

I. NAILS

J. EXPOSED HARDWARE

K. VINYL GRAPHICS

3. REMOVE FINISHES TO A LEVEL SUITABLE FOR INSTALLATION

OF NEW FINISHES, WHERE APPLICABLE. REFER TO NEW

CONSTRUCTION DRAWINGS FOR ADDITIONAL

INFORMATION.

4. FURNITURE REMOVAL BY OWNER.

5. AS REQUIRED, ANY DISRUPTED FIREPROOFING OF ALL

BUILDING STRUCTURAL MEMBERS WALLS, FLOORS AND

CEILING, SHALL BE SUPPLEMENTED AFTER DEMOLITION, IN

ACCORDANCE WITH ALL CURRENTLY APPLICABLE CODES,

REGULATION AND ORDINANCES OF ALL GOVERNING

BODIES HAVING JURISIDTION OVER THE PROJECT.

6. THIS PLAN IS MEANT TO OUTLINE THE GENERAL SCOPE OF

DEMOLITION FOR THE CONTRACTORS. THE SPECIFIC

AREAS, ITEMS, DETAILS, MATERIALS, EXTENT, ETC. OF

DEMOLITION WILL BE A RESULT OF FIELD CONDITIONS. THE

INTENT IS THAT ALL DEMOLITION REQUIRED TO PROPERLY

CONSTRUCT THIS PROJECT IS THE RESPONSIBILITY OF THE

PRIME CONTRACTORS. THE CONTRACTORS WILL ENSURE

THE EXISTING BUILDING RETAINS STRUCTURAL INTEGRITY

AND REMAINS WATER AND WEATHER-TIGHT DURING THE

DEMOLITION AND CONSTRUCTION PHASES OF THE WORK.

7. UNDER-SLAB WORK INVOLVES THE GENERAL

CONSTRUCTION (GC), PLUMBING (PC), AND ELECTRICAL

(EC) PRIME CONTRACTORS. RESPONSIBILITIES ARE ASSIGNED

AS FOLLOWS:

1. GC: SAW CUT AND REMOVE THE EXISTING SLAB-ON-

GRADE AS REQUIRED TO ACCOMMODATE THE UNDER-

SLAB PLUMBING, ELECTRICAL, AND STRUCTURAL WORK.

PROTECT THE EXISTING CONSTRUCTION TO REMAIN.

2. GC: AT NEW STEEL COLUMN LOCATIONS, EXPOSE THE

EXISTING WALL FOOTING AND VERIFY ITS SIZE AND

CONDITION IN THE FIELD BEFORE INSTALLING THE STEEL

COLUMNS. REPORT ANY DISCREPANCIES WITH THE

CONTRACT DOCUMENTS TO THE ARCHITECT IN

WRITING. REFER TO DETAIL 1/S5.0.

3. PC AND EC: EXCAVATE, INSTALL THE UNDER-SLAB

PLUMBING AND ELECTRICAL WORK, AND BACKFILL TO

SUBGRADE ELEVATION, IN ACCORDANCE WITH THE

CONTRACT DOCUMENTS. COMPLETE ALL REQUIRED

INSPECTIONS AND TESTING BEFORE BACKFILLING.

4. GC: INSTALL A 10 MIL VAPOR BARRIER AND THE NEW

CONCRETE SLAB, TIED INTO THE EXISTING SLAB, AS

INDICATED ON THE STRUCTURAL DRAWINGS. MATCH

THE EXISTING SLAB ELEVATION AND FINISH.

THE PRIME CONTRACTORS SHALL COORDINATE THE

EXTENT, LOCATION, AND SEQUENCE OF THEIR WORK WITH

EACH OTHER. REFER TO DIVISION 01 FOR MULTIPLE-PRIME

CONTRACT RESPONSIBILITIES.

DEMOLITION PLAN SHEET NOTES

AREA OF BASE

SCOPE

83 90 91 92 93 94 95 96 97 98 99 100 101102 103 104

107115

AD200

AD200

RE

TA

IN

E

XI

ST

IN

G

V C

T

D

EM

O

AD200

120.1

120.2

10' - 0 3/8"

AD200

01 V.

I.F

04 04 04

04 04 04 04 04

13 13

13 13

03 03

17 17 17

17 1714

18 18

20 20

20 20 20 20

11 11

11 11 11

AD200

A601

A601

A601

A601

V.I.F.

28' - 7"

AD200 2

A601

A400

30 30

SHEET KEYNOTES

X00 = KEYNOTE TAG

DATE ISSUED FOR

H E

C K

E N

D O

R N

S H

IL

E

S A

R C

H

IT

E C

T S e xp re s s ly r e s e rv e s i ts c o m m o n l a w c o p y ri g h t a n d o th e r p ro p e rt y r ig h ts i n t h e s e p la n s T h e s e a re n o t to b e r e p ro d u c e d n o r a re t h e y t o b e a s s ig n e d t o a n y t h ir d p a rt y w it h o u t fi rs t o b ta in in g t h e e xp re s s e d w ri tt e n c o n s e n t o f H

E C

K E

N D

O R

N S

H

IL

E S

A R

C H

IT

E

C T

S

CLIENT

DRAWING NUMBER

SHEET TITLE

KEYPLAN

ISSUE HISTORY

PROJECT TEAM

ARCHITECTURAL

Heckendorn Shiles Architects 347 East Conestoga Road Wayne, PA 19087 610-994-3500

NOT FOR

CONSTRUCTION

OUT OF ARCHITECTURAL SCOPE

PLAN

NORTH

LEGEND

/1 /2

:5

:5

P M

AD101

EXISTING CONDITIONS

& DEMOLITION - FIRST

FLOOR PLAN

AGCS STATE ROAD

ADMINISTRATION

110 E State Rd, West Grove, PA 19390

HSA PROJECT # :26-004

Avon Grove Charter School 110 E State Rd West Grove, PA 19390 484-667-5000

Orndorf & Associates, Inc 8600 West Chester Pike, Suite Upper Darby, PA 19802

STRUCTURAL

Schiller & Hersh Associates, Inc.

636 Skippack Pike, Suite 200 Blue Bell, PA 19422 215-886-8947

MEPFP

3/16" = 1'-0"AD101

1 EXISTING CONDITIONS & DEMOLITION - FIRST FLOOR PLAN

01 REMOVE EXISTING CAST IN PLACE SIDEWALK

02 REMOVE EXISTING CONCRETE RAMP AND

HANDRAILS

03 REMOVE EXISTING CANOPY AND SUPPORT

STRUCTURE. SEE DEMOLITION RCP /

DEMOLITION ROOF PLAN FOR ADDITIONAL

SCOPE

04 REMOVE EXISTING WALL PTAC UNITS, AND

PROVIDE WEATHER TIGHT INFILL OF SIMILAR

THERMAL VALUE. PROVIDE TEMP

PROTECTION FROM THE ELEMENTS DURING

CONSTRUCTION

05 EXISTING PANELS TO REMAIN AND BE

PROTECTED DURING DEMOLITION. SEE

MEPFP FOR ADDITIONAL INFORMATION.

06 EXISTING PANELS AND CONDUIT TO BE

REMOVED. SEE MEPFP FOR ADDITIONAL

INFORMATION.

07 EXISTING FLOOR HATCH TO CRAWL SPACE

TO BE REMOVED.

08 REMOVE PTD WOOD COVER PIPE

ENCLOSURE

09 REMOVE PLUMBING FIXTURES, REFER TO

PLUMBING DWGS FOR ADDITIONAL

INFORMATION

10 REMOVE EXISTING VCT FLOOR FINISH.

COORDINATE EXTENTS WITH NEW

PARTITIONS AND NEW CONSTRUCTION

FINISH PLAN

11 REMOVE EXISTING FLOOR FINISH

THROUGHOUT

12 REMOVE CASEWORK (BASE CABINETS AND

UPPER CABINETS, AND COUNTERTOP

13 REMOVE DOOR AND FRAME

14 REMOVAL EXISTING TRANSOM WINDOWS

OVERHEAD BY ABATEMENT CONTRACTOR.

REFER TO AD200 FOR ADDITIONAL

INFORMATION.

15 REMOVE WALL HUNG CASEWORK OPEN

SHELVING

16 EXTENT OF EXISTING BLOCK / PARTITION

WALL TO REMAIN

17 REMOVAL OF EXISTING WINDOW BY

ABATEMENT CONTRACTOR

18 REMOVE EXISTING BLOCK WALL

19 REMOVE EXISTING BRICK MASONRY LOAD

BEARING WALL. REFER TO STRUCTURAL

DWGS FOR ADDITIONAL INFORMATION.

20 REMOVE EXISTING METAL LATHE AND

PLASTER WALLS THROUGHOUT

21 REMOVE VESTIBULE WALK OFF CARPET

30 EXISTING CR TO BE PROTECTED, REMOVE /

INSTALL AS REQUIRED FOR NEW WALL FINISH

31 LOCATION OF EXISTING EXTERIOR GRILL.

PRIME CONTRACTOR TO FIELD VERIFY

CONNECTION TO EXISTING

INFRASTRUCTURE AND NOTIFY ARCHITECT.

PROVIDE WEATHER TIGHT INFILL OF SIMILAR

THERMAL VALUE, FINISH FACE TO MATCH

SURROUNDING EXTERIOR WALL

32 REMOVE CONCRETE SLAB FOR NEW ACCESS

HATCH. COORDINATE LOCATION WITH

CONSTRUCTION PLAN

1 11-09-2026 BID ISSUE

SD

CFHCFH

SD SD SD SD

25 25

25 25

SHEET KEYNOTES

X00 = KEYNOTE TAG

AREA OF BASE

SCOPE

DATE ISSUED FOR

H E

C K

E N

D O

R N

S H

IL

E

S A

R C

H

IT

E C

T S e xp re s s ly r e s e rv e s i ts c o m m o n l a w c o p y ri g h t a n d o th e r p ro p e rt y r ig h ts i n t h e s e p la n s T h e s e a re n o t to b e r e p ro d u c e d n o r a re t h e y t o b e a s s ig n e d t o a n y t h ir d p a rt y w it h o u t fi rs t o b ta in in g t h e e xp re s s e d w ri tt e n c o n s e n t o f H

E C

K E

N D

O R

N S

H

IL

E S

A R

C H

IT

E

C T

S

CLIENT

DRAWING NUMBER

SHEET TITLE

KEYPLAN

ISSUE HISTORY

PROJECT TEAM

ARCHITECTURAL

Heckendorn Shiles Architects 347 East Conestoga Road Wayne, PA 19087 610-994-3500

NOT FOR

CONSTRUCTION

OUT OF ARCHITECTURAL SCOPE

PLAN

NORTH

LEGEND

/1 /2

:5

:5

P M

AD102

EXISTING CONDITIONS

& DEMOLITION - ROOF

PLAN

AGCS STATE ROAD

ADMINISTRATION

110 E State Rd, West Grove, PA 19390

HSA PROJECT # :26-004

Avon Grove Charter School 110 E State Rd West Grove, PA 19390 484-667-5000

Orndorf & Associates, Inc 8600 West Chester Pike, Suite Upper Darby, PA 19802

STRUCTURAL

Schiller & Hersh Associates, Inc.

636 Skippack Pike, Suite 200 Blue Bell, PA 19422 215-886-8947

MEPFP

3/16" = 1'-0"AD102

1 EXISTING CONDITIONS AND DEMOLITION - ROOF PLAN

03 REMOVE EXISTING CANOPY AND SUPPORT

STRUCTURE. SEE DEMOLITION RCP /

DEMOLITION ROOF PLAN FOR ADDITIONAL

SCOPE

22 REMOVE ROOF DRAIN

23 COORDINATE REMOVAL OF EXISTING CANOPY

ROOF MEMBRANE TO ALLOW FOR FUTURE

REINSTALLATION OF PARAPET / ROOF

MEMBRANE

24 REMOVE EXISTING COPING

25 REMOVE ROOF CAP AND CURB. SEE ROOF

PATCHING DETAILS. REFER TO MECH DWGS.

FOR ADD'L INFORMATION

28 PROVIDE NEW OPENING IN SIDE OF EXISTING

BRICK WALL FOR NEW DRAIN PATHS. SEE

ELEVATIONS FOR ADD'L INFORMATION.

29 REMOVE EXISTING GUTTER

1 11-09-2026 BID ISSUE

AREA OF BASE

SCOPE

KEYPLAN

SDSD SD SD SD

CR

S S

S

1 1111 1 1 111111 3

4 4

4 4

4 4

7 7 7

7 7 7 7

7 7

V.I.F.

29' - 6 7/8"

AD200 2

A2005

1. THIS PLAN IS MEANT TO OUTLINE THE GENERAL SCOPE OF

DEMOLITION FOR THE CONTRACTORS. THE SPECIFIC

AREAS, ITEMS, DETAILS, MATERIALS, EXTENT, ETC. OF

DEMOLITION WILL BE A RESULT OF FIELD CONDITIONS. THE

INTENT IS THAT ALL DEMOLITION REQUIRED TO PROPERLY

CONSTRUCT THIS PROJECT IS THE RESPONSIBILITY OF THE

PRIME CONTRACTORS. THE CONTRACTORS WILL ENSURE

THE EXISTING BUILDING RETAINS STRUCTURAL INTEGRITY

AND REMAINS WATER AND WEATHER-TIGHT DURING THE

DEMOLITION AND CONSTRUCTION PHASES OF THE WORK.

DEMOLITION RCP PLAN SHEET NOTES

S S

S

2 2222 2 2 222222 3

7 7 7

7 7 7 7

7 7

SHEET KEYNOTES

X00 = KEYNOTE TAG

3/16" = 1'-0"AD110

1 EXISTING CONDITIONS & DEMOLITION - RCP - BASE SCOPE

DATE ISSUED FOR

H E

C K

E N

D O

R N

S H

IL

E

S A

R C

H

IT

E C

T S e xp re s s ly r e s e rv e s i ts c o m m o n l a w c o p y ri g h t a n d o th e r p ro p e rt y r ig h ts i n t h e s e p la n s T h e s e a re n o t to b e r e p ro d u c e d n o r a re t h e y t o b e a s s ig n e d t o a n y t h ir d p a rt y w it h o u t fi rs t o b ta in in g t h e e xp re s s e d w ri tt e n c o n s e n t o f H

E C

K E

N D

O R

N S

H

IL

E S

A R

C H

IT

E

C T

S

CLIENT

DRAWING NUMBER

SHEET TITLE

KEYPLAN

ISSUE HISTORY

PROJECT TEAM

ARCHITECTURAL

Heckendorn Shiles Architects 347 East Conestoga Road Wayne, PA 19087 610-994-3500

NOT FOR

CONSTRUCTION

OUT OF ARCHITECTURAL SCOPE

SECTOR DESIGNATION

PLAN

NORTH

LEGEND

MISC ITEM AS NEEDED

MISC ITEM AS NEEDED

/1 /2

:5

:5

P M

AD110

EXISTING CONDITIONS

& DEMOLITION - FIRST

FLOOR RCP

AGCS STATE ROAD

ADMINISTRATION

110 E State Rd, West Grove, PA 19390

HSA PROJECT # :26-004

Avon Grove Charter School 110 E State Rd West Grove, PA 19390 484-667-5000

Orndorf & Associates, Inc 8600 West Chester Pike, Suite Upper Darby, PA 19802

STRUCTURAL

Schiller & Hersh Associates, Inc.

636 Skippack Pike, Suite 200 Blue Bell, PA 19422 215-886-8947

MEPFP

1 11-09-2026 BID ISSUE

3/16" = 1'-0"AD110

2 EXISTING CONDITIONS & DEMOLITION - RCP - ALTERNATE SCOPE

1 BASE SCOPE: RETAIN EXISTING CORRIDOR

LIGHTING AND CEILING GRID. REMOVE

EXISTING ACT TILES AND ADJUST EXISTING

GRID AND EXISTING DEVICES TO PREPARE

FOR NEW CONSTRUCTION.

2 ALTERNATE SCOPE: REMOVE EXISTING

CORRIDOR LIGHTING, CEILING GRID. ACT

AND CEILING DEVICES ENTIRELY. SEE

ALTERNATE NEW CONSTRUCTION RCP.

3 REMOVE EXISTING CEILING MOUNTED

CABINET UNIT HEATER. SEE MEPFP DRAWINGS

FOR NEW LOCATION.

4 REMOVE EXISTING CEILINGS, GRID, LIGHT

FIXTURES AND CEILING DEVICES

5 CARD READER AND CAMERA TO BE

RELOCATED. COORDINATE WITH NEW

EXTERIOR WALL FINISH

6 REMOVE EXISTING LIGHTING FIXTURES. SEE

ELECTRICAL FOR ADDITIONAL INFORMATION

7 REMOVE, STORE AND REINSTALL EXISTING

CEILING DEVICES. SEE ELECTRICAL DRAWINGS

FOR ADDITONAL INFORMATION

8 LINE OF EXISTING STRUCTURAL STEEL TO BE

PROTECTED DURING DEMOLITION.

9 REMOVE EXISTING FASCIA AND SOFFIT AND

SUB FRAMING BACK TO STOREFRONT

10 REMOVE EXISTING CANOPY AND STRUCTURE,

REMOVE COLUMNS DOWN TO BELOW

GRADE. COORDINATE DEMOLITION EXTENTS

WITH NEW CONSTRUCTION.

AREA OF BASE

SCOPE

KEYPLAN

PLAN

NORTH

AREA OF BASE

B.O. LOW ROOF DECK

9' - 5 5/8"

1955 BLDG - FIRST FLOOR

0' - 0"

AD200

B.O. HIGH ROOF DECK

11' - 0"

AD200

GRADE

-1' - 0"

AD200

17 17 17 17 17

242622

04 04 04 04 040404 31

SHEET KEYNOTES

X00 = KEYNOTE TAG

B.O. LOW ROOF DECK

9' - 5 5/8"

AD200

ADMIN AREA

/8

CORRIDOR

AD200

B.O. HIGH ROOF DECK

11' - 0"

GRADE

-1' - 0"

CORRIDORADMIN AREA KITCHENETTE

/8

B.O. LOW ROOF DECK

9' - 5 5/8"

1955 BLDG - FIRST FLOOR

0' - 0"

AD200

B.O. HIGH ROOF DECK

11' - 0"

AD200

GRADE

-1' - 0"

AD200

V.

I.F

/4

V.

I.F

3/16" = 1'-0"AD200

3 OVERALL EXISTING LONGITUDINAL BUILDING SECTION

3/16" = 1'-0"AD200

4 EXISTING SECTOR B CROSS SECTION

DATE ISSUED FOR

H E

C K

E N

D O

R N

S H

IL

E

S A

R C

H

IT

E C

T S e xp re s s ly r e s e rv e s i ts c o m m o n l a w c o p y ri g h t a n d o th e r p ro p e rt y r ig h ts i n t h e s e p la n s T h e s e a re n o t to b e r e p ro d u c e d n o r a re t h e y t o b e a s s ig n e d t o a n y t h ir d p a rt y w it h o u t fi rs t o b ta in in g t h e e xp re s s e d w ri tt e n c o n s e n t o f H

E C

K E

N D

O R

N S

H

IL

E S

A R

C H

IT

E

C T

S

CLIENT

DRAWING NUMBER

SHEET TITLE

ISSUE HISTORY

PROJECT TEAM

ARCHITECTURAL

Heckendorn Shiles Architects 347 East Conestoga Road Wayne, PA 19087 610-994-3500

NOT FOR

CONSTRUCTION

OUT OF ARCHITECTURAL SCOPE

PLAN

NORTH

LEGEND

/1 /2

:5

:0

P M

AD200

EXISTING CONDITIONS

& DEMO - EXT. ELEV'S

AND SECTIONS

AGCS STATE ROAD

ADMINISTRATION

110 E State Rd, West Grove, PA 19390

HSA PROJECT # :26-004

Avon Grove Charter School 110 E State Rd West Grove, PA 19390 484-667-5000

Orndorf & Associates, Inc 8600 West Chester Pike, Suite Upper Darby, PA 19802

STRUCTURAL

Schiller & Hersh Associates, Inc.

636 Skippack Pike, Suite 200 Blue Bell, PA 19422 215-886-8947

MEPFP

3/16" = 1'-0"AD200

1 EXISTING CONDITIONS & DEMOLITION SOUTH EXTERIOR ELEVATION

3/16" = 1'-0"AD200

5 EXISTING SECTOR A CROSS SECTION

3/16" = 1'-0"AD200

6 EXISTING CANOPY CROSS SECTION

04 REMOVE EXISTING WALL PTAC UNITS, AND

PROVIDE WEATHER TIGHT INFILL OF SIMILAR

THERMAL VALUE. PROVIDE TEMP

PROTECTION FROM THE ELEMENTS DURING

CONSTRUCTION

14 REMOVAL EXISTING TRANSOM WINDOWS

OVERHEAD BY ABATEMENT CONTRACTOR.

REFER TO AD200 FOR ADDITIONAL

INFORMATION.

17 REMOVAL OF EXISTING WINDOW BY

ABATEMENT CONTRACTOR

22 REMOVE ROOF DRAIN

24 REMOVE EXISTING COPING

26 REMOVE, PROTECT AND STORE LETTERING

FOR REINSTALLATION

31 LOCATION OF EXISTING EXTERIOR GRILL.

PRIME CONTRACTOR TO FIELD VERIFY

CONNECTION TO EXISTING

INFRASTRUCTURE AND NOTIFY ARCHITECT.

PROVIDE WEATHER TIGHT INFILL OF SIMILAR

THERMAL VALUE, FINISH FACE TO MATCH

SURROUNDING EXTERIOR WALL

1 11-09-2026 BID ISSUE

1. BUILDING SECTIONS PROVIDED FOR REFERNCE TO

INDICATE EXISTING HEIGHTS AND TRANSITIONS.

2. ALL EXISTING DIMENSIONS TO BE FIELD VERIFIED

3/16" = 1'-0"AD200

2 DEMO WEST ELEVATION

1. REFER TO SHEET A001 FOR ADDITIONAL NEW

CONSTRUCTION NOTES.

2. REFER TO A600 FOR PARTITION SCHEDULE

3. REFER TO A601 FOR DOOR AND FRAME SCHEDULE

4. ALL DIMENSIONS ARE TO FINISHED FACE, UNO.

5. ALL EXTERIOR WALL AND ROOF PENETRATIONS TO BE MADE

BY GC. REFER TO MECHANICAL, PLUMBING AND

ELECTRICAL DRAWINGS FOR PENETRATIONS REQUIRED. MC,

PC AND EC TO PROVIDE FINAL SIZE AND LAYOUT ON SITE

FOR GC COORDINATION. REFER TO A500 SERIES FOR

TYPICAL DETAILS.

6. ALL INTERIOR WALL PENETRATIONS TO BE MADE BY PRIME

CONTRACTOR REQUIRING THE PENETRATION, UNO. EACH

PRIME IS RESPONSIBLE FOR PROTECTION OF EXISTING

CONDITIONS TO REMAIN (INCLUDNG BUT NOT LIMITED TO

FLOORING, WALLS, FURNITURE).

7. PATCH/FILL/REPAIR ALL EXISTING PARTITIONS WITHIN SCOPE

OF WORK WHERE MEP/FP DEVICES HAVE BEEN REMOVED

AND WHERE A PORTION OF WALL HAS BEEN REMOVED FOR

A NEW MEP/FP DEVICE, INCLUDING BUT NOT LIMTED TO

PANELS, ATTACHMENTS, FIXTURES AND DEVICES, U.N.O.

COORDINATE LOCATIONS WITH MEP/FP CONTRACTORS

AND REFER TO MEP/FP DWGS FOR ADDITIONAL INFO

8. PREP ALL SURFACES FOR NEW FINISH, COORDINATE

FINISHES WITH A12 SERIES FINISH DRAWINGS.

9. EXISTING FLOOR SLAB SHALL BE PATCHED, REPAIRED,

REFINISHED AND LEVELED AS REQUIRED TO RECEIVE NEW

FINISH MATERIALS.

10. FIRE EXTINGUISHER NOTE:

A. UTILIZE EXISTING/RELOCATE SEMI-RECESSED FIRE

EXTINGUISHERS/CABINETS AS REQUIRED BY CODE. GC

TO PROVIDE NEW.

B. (NEW ) ALL FIRE EXTINGUISHERS/CABINETS ARE NEW.

PROVIDE AND INSTALL NEW BUILDING STANDARD SEMI-

RECESSED FIRE EXTINGUISHERS. CABINETS AS INDICATED

AND REQUIRED B CODE. PROVIDE AN INSTALL "FIRE

EXTINGUISHER" STAND-OUT SIGNS ARE REQUIRED BY

CODE ABOVE CABINET. (SPECIFICATION: BROOKS

EQUIPMENT CO., INC. PTD182 "FIRE EXTINGUISHER"

STAND-OUT SIGN)

11. PROVIDE AND INSTALL ADA COMPLIANT WALL-MOUNTED

EXIT SIGNS (TACTILE) AT EACH EXIT DOOR AS REQUIRED TO

MEET ADA, LIFE SAFETY CODE, AND ALL APPLICABLE LOCAL

CODES.

12. PROVIDE SS-1 WINDOW STOOLS AT ALL NEW STOREFRONT

OPENINGS.

13. GC TO PATCH/REPAIR CONCRETE FLOOR SLAB AT

LOCATIONS OF REMOVED/CAPPED PLUMBING FIXTURES

DRAIN LINES.

NEW CONSTRUCTION SHEET NOTES

83 90 91 92 93 94 95 96 97 98 99 100 101102 103 104

107115

A200

GREETER /

RECEPTION

OFFICE

OFFICE

COLLAB.

ADMIN

WAITING

KITCHENETTE

RR

STORAGE

UTILITY

OFFICE

MOTHER'S

ROOM

RECEPTION

STORAGE

OFFICE

OFFICE

NURSES

STATION

RR

COTS

STORAGE

PACKAGES

LOST &

FOUND

S E C

T O

R A

A401

S E C

T O

R B

A300

A300

A400

120.1

120.2

MAIL

COPY /

PRINT

11001

A402

C A

N O

P Y

S E C

T O

R A

A402

A200 2

A200 3

07 08

06 01

8' - 11 1/2"13' - 6"14' - 5"10' - 0" 4' - 10 7/8"

6' - 1"7' - 4 3/8"

10' - 5 3/4" 10' - 4 1/2" 10' - 4 1/4"

/8

/4

/8

12 8' - 9 1/4"

CORRIDOR

A300

" EQ-01

6' - 0"

VESTIBULE

CORRIDOR

10 10 10

50 50 50

125124

117 118

104103

102A 102B

101A

101B

5' - 0" OC TYP

EQ EQ

52 52

' - 6

EDGE OF CURB

SHEET KEYNOTES

X00 = KEYNOTE TAG

DATE ISSUED FOR

H E

C K

E N

D O

R N

S H

IL

E

S A

R C

H

IT

E C

T S e xp re s s ly r e s e rv e s i ts c o m m o n l a w c o p y ri g h t a n d o th e r p ro p e rt y r ig h ts i n t h e s e p la n s T h e s e a re n o t to b e r e p ro d u c e d n o r a re t h e y t o b e a s s ig n e d t o a n y t h ir d p a rt y w it h o u t fi rs t o b ta in in g t h e e xp re s s e d w ri tt e n c o n s e n t o f H

E C

K E

N D

O R

N S

H

IL

E S

A R

C H

IT

E

C T

S

CLIENT

DRAWING NUMBER

SHEET TITLE

KEYPLAN

ISSUE HISTORY

PROJECT TEAM

ARCHITECTURAL

Heckendorn Shiles Architects 347 East Conestoga Road Wayne, PA 19087 610-994-3500

NOT FOR

CONSTRUCTION

OUT OF ARCHITECTURAL SCOPE

PLAN

NORTH

LEGEND

/1 /2

:5

:0

P M

A101

NEW CONSTRUCTION

PLAN

AGCS STATE ROAD

ADMINISTRATION

110 E State Rd, West Grove, PA 19390

HSA PROJECT # :26-004

Avon Grove Charter School 110 E State Rd West Grove, PA 19390 484-667-5000

Orndorf & Associates, Inc 8600 West Chester Pike, Suite Upper Darby, PA 19802

STRUCTURAL

Schiller & Hersh Associates, Inc.

636 Skippack Pike, Suite 200 Blue Bell, PA 19422 215-886-8947

MEPFP

3/16" = 1'-0"A101

1 NEW CONSTRUCTION - FIRST FLOOR PLAN

01 CASEWORK, BASE CABINETS WITH COUNTER

02 CASEWORK, FULL HEIGHT CABINET

03 CASEWORK - BASE CABINETS AND OPEN COUNTER

04 PRINTER EQUIPMENT COORDINATE ELECTRICAL AND

TELE/DATA REQUIREMENTS

05 CASEWORK - BASE CABINET, COUNTER WITH SINK,

UPPER CABINETS

06 MAIL SORTING FURNITURE BY OWNER

07 PROVIDE 24"X24" REMOVABLE FLOOR HATCH FOR

CONCRETE W/ RECESS TO RECIEVE CARPET.

COORDINATE FINAL LOCATION WITH EXISTING

STRUCTURE BELOW. INSTALL INTO EXISTING CRAWL

SPACE. COORDINATE INSTALLATION OF FLOOR FINISH

INTO ACCESS PANEL RESINFORCE SLAB AND DECK PRIOR

TO CUTTING, REFER TO STRUCTURAL DWGS FOR ADD'L

INFO.

08 INFILL EXISTING ACCESS HOLE WITH CONCRETE

COMPOSITE SLAB FLUSH TO EXISTING CONCRETE SLAB.

PROVIDE C6 BELOW ANCHERSED TO EXISTIGN

STRUCTURE. PROVIDE 4 1/2" NORLA WEIGHT

CONCRETE W/ 6X6-W2.1 X S2.1 WWF ON 3", 20 GA

COMPOSITE METAL DECK

09 INSTALL ADA PUSHBUTTON TO OPERATE EXISTING AUTO

OPERATOR,

AT BUBBLED MAIN ENTRANCE DOUBLE DOORS.

COORDINATE WITH ELECTRICAL

TO CAPTURE INTENT AND SECURITY VENDOR, INSTALLER

10 CLEAR ANNODIZED ALUMINUM STOREFRONT SYSTEM W/

1" INSULATED GLAZING. REFER TO ENLARGED

ELEVATIONS FOR ADD'L INFO. BOD: YKK YES 45 TU

11 SLOPED CONCRETE SLAB, OVERBUILT OVER EXISTING

STAIRS. DOWEL TO EXISTING STAIR , PROVIDE 4"

CONCRETE ON 4" 2B STONE BASE, UNO.

12 PROVIDE GWB ON 7/8" HAT CHANNELS ON THIS WALL

13 GC TO PATCH/REPAIR CONCRETE SLAB AT LOCATION

OF PLUMBING TRENCH. PC TO BACKFILL AND COMPACT

SOIL, GC TO PROVIDE VAPOR BARRIER, STONE AND

CONCRETE PER STRUCTURAL DETAIL.

14 GC PATCH/REPAIR CONCRETE SLAB AT LOCATION OF

MASONRY WALL REMOVAL. GC TO BACKFILL AND

COMPACT SOIL, PROVIDE STONE, VAPOR BARRIER AND

CONCRETE PER STRUCTURAL DETAIL.

49 PATCH ALL EXISTING RAILING PENETRATIONS WITH NON

SHRINK GROUT FLUSH TO ADJACENT CONCRETE

50 ADD ALTERNATE: BOLLARDS SPACED 5'-0" O.C., 18"

INBOUND OF CURB LINE. SEE A505 FOR DETAILS

51 GWB CASED OPENING

52 EXPOSED ARCHITECTRAL CONCRETE PIER WITH

STRUCTURAL STEEL V-COLUMN. STEEL TO BE HOT DIP

GALVANIZED FACTORY APPLIED POWDER COATED STEEL.

BD FOR FINISH: COLORGAV THERMOSET

55 PROVIDE CASEWORK OPEN SHELVING

1 11-09-2026 BID ISSUE

AREA OF BASE

SCOPE

KEYPLAN

PLAN

NORTH

AREA OF BASE

CFHCFH

1. REFER TO SHEET A001 FOR ADDITIONAL NEW

CONSTRUCTION NOTES.

2. REFER TO A600 FOR PARTITION SCHEDULE

3. REFER TO A601 FOR DOOR AND FRAME SCHEDULE

4. ALL DIMENSIONS ARE TO FINISHED FACE, UNO.

5. ALL EXTERIOR WALL AND ROOF PENETRATIONS TO BE MADE

BY GC. REFER TO MECHANICAL, PLUMBING AND

ELECTRICAL DRAWINGS FOR PENETRATIONS REQUIRED. MC,

PC AND EC TO PROVIDE FINAL SIZE AND LAYOUT ON SITE

FOR GC COORDINATION. REFER TO A500 SERIES FOR

TYPICAL DETAILS.

6. ALL INTERIOR WALL PENETRATIONS TO BE MADE BY PRIME

CONTRACTOR REQUIRING THE PENETRATION, UNO. EACH

PRIME IS RESPONSIBLE FOR PROTECTION OF EXISTING

CONDITIONS TO REMAIN (INCLUDNG BUT NOT LIMITED TO

FLOORING, WALLS, FURNITURE).

7. PATCH/FILL/REPAIR ALL EXISTING PARTITIONS WITHIN SCOPE

OF WORK WHERE MEP/FP DEVICES HAVE BEEN REMOVED

AND WHERE A PORTION OF WALL HAS BEEN REMOVED FOR

A NEW MEP/FP DEVICE, INCLUDING BUT NOT LIMTED TO

PANELS, ATTACHMENTS, FIXTURES AND DEVICES, U.N.O.

COORDINATE LOCATIONS WITH MEP/FP CONTRACTORS

AND REFER TO MEP/FP DWGS FOR ADDITIONAL INFO

8. PREP ALL SURFACES FOR NEW FINISH, COORDINATE

FINISHES WITH A12 SERIES FINISH DRAWINGS.

9. EXISTING FLOOR SLAB SHALL BE PATCHED, REPAIRED,

REFINISHED AND LEVELED AS REQUIRED TO RECEIVE NEW

FINISH MATERIALS.

10. FIRE EXTINGUISHER NOTE:

A. UTILIZE EXISTING/RELOCATE SEMI-RECESSED FIRE

EXTINGUISHERS/CABINETS AS REQUIRED BY CODE. GC

TO PROVIDE NEW.

B. (NEW ) ALL FIRE EXTINGUISHERS/CABINETS ARE NEW.

PROVIDE AND INSTALL NEW BUILDING STANDARD SEMI-

RECESSED FIRE EXTINGUISHERS. CABINETS AS INDICATED

AND REQUIRED B CODE. PROVIDE AN INSTALL "FIRE

EXTINGUISHER" STAND-OUT SIGNS ARE REQUIRED BY

CODE ABOVE CABINET. (SPECIFICATION: BROOKS

EQUIPMENT CO., INC. PTD182 "FIRE EXTINGUISHER"

STAND-OUT SIGN)

11. PROVIDE AND INSTALL ADA COMPLIANT WALL-MOUNTED

EXIT SIGNS (TACTILE) AT EACH EXIT DOOR AS REQUIRED TO

MEET ADA, LIFE SAFETY CODE, AND ALL APPLICABLE LOCAL

CODES.

12. PROVIDE SS-1 WINDOW STOOLS AT ALL NEW STOREFRONT

OPENINGS.

13. GC TO PATCH/REPAIR CONCRETE FLOOR SLAB AT

LOCATIONS OF REMOVED/CAPPED PLUMBING FIXTURES

DRAIN LINES.

NEW CONSTRUCTION SHEET NOTES

83 90 91 92 93 94 95 96 97 98 99 100 101102 103 104

107115

A300

120.1

120.2

A300

17 16

/4

'-0

" M

IN

A2005

/8

" V

IF

/2

" V

IF

EDGE OF CURB

PR

O

VI

D

E

BU

IL

T

U P

IN

SU

LA

TI

O N

F O

R

/4 O

VE

R

' S

LO

PE

107115

120.1

120.2

A2005

SHEET KEYNOTES

X00 = KEYNOTE TAG

DATE ISSUED FOR

H E

C K

E N

D O

R N

S H

IL

E

S A

R C

H

IT

E C

T S e xp re s s ly r e s e rv e s i ts c o m m o n l a w c o p y ri g h t a n d o th e r p ro p e rt y r ig h ts i n t h e s e p la n s T h e s e a re n o t to b e r e p ro d u c e d n o r a re t h e y t o b e a s s ig n e d t o a n y t h ir d p a rt y w it h o u t fi rs t o b ta in in g t h e e xp re s s e d w ri tt e n c o n s e n t o f H

E C

K E

N D

O R

N S

H

IL

E S

A R

C H

IT

E

C T

S

CLIENT

DRAWING NUMBER

SHEET TITLE

ISSUE HISTORY

PROJECT TEAM

ARCHITECTURAL

Heckendorn Shiles Architects 347 East Conestoga Road Wayne, PA 19087 610-994-3500

NOT FOR

CONSTRUCTION

PLAN

NORTH

/1 /2

:5

:0

P M

A102

NEW CONSTRUCTION

ROOF PLAN

AGCS STATE ROAD

ADMINISTRATION

110 E State Rd, West Grove, PA 19390

HSA PROJECT # :26-004

Avon Grove Charter School 110 E State Rd West Grove, PA 19390 484-667-5000

Orndorf & Associates, Inc 8600 West Chester Pike, Suite Upper Darby, PA 19802

STRUCTURAL

Schiller & Hersh Associates, Inc.

636 Skippack Pike, Suite 200 Blue Bell, PA 19422 215-886-8947

MEPFP

3/16" = 1'-0"A102

1 NEW CONSTRUCTION - ROOF PLAN

1 11-09-2026 BID ISSUE

3/16" = 1'-0"A102

2 NEW CONSTRUCTION - LOW ROOF PLAN

16 NEW DEDICATED OUTDOOR AIR UNIT ON 18" HIGH

ROOF CURB FURNISHED BY MC. GC TO PROVIDE

ROOF OPENING AND FRAMING PER STRUCTURAL

(1/S5.1, 2/S5.1), AND ROOFING AND CURB FLASHING

PER 15/A506. REFER TO MECHANICAL DRAWINGS FOR

UNIT, SIZE AND LOCATION.PROVIDE PT BLOCKNG

FOR LEVELING CURBS AND RAILS. COORDINATE

ROOF CRICKETS TO DIVERT WATER AROUND

CURBS/SUPPORTS/EQUIPMENT AS REQUIRED. SEAL

ROOF PER ROOF PENETRATION DETAILS.

17 NEW OUTDOOR HEAT RECOVERY UNIT ON

EQUIPMENT RAILS PER 17/A506. SUPPORT PER

STRUCTURAL DRAWINGS. REFER TO MECHANICAL

DRAWINGS FOR UNIT AND LOCATION.

18 REFRIGERANT PIPING AND CONDUIT PENETRATIONS

SERVING ROOFTOP EQUIPMENT. FLASH PER 4/A506

OR 13/A506 AS APPLICABLE. MC AND EC TO

COORDINATE LOCATIONS WITH GC.

19 PLUMBING VENT THROUGH ROOF. GC TO PROVIDE

OPENING AND FLASHING PER 14/A506 AND 11/A506.

REFER TO PLUMBING DRAWINGS.

20 NEW EXHAUST FAN ON ROOF CURB FURNISHED BY

MC. GC TO PROVIDE ROOF OPENING, FRAMING PER

STRUCTURAL, AND CURB FLASHING PER 15/A506.

REFER TO MECHANICAL DRAWINGS.

21 NEW GRAVITY VENTILATOR ON ROOF CURB

FURNISHED BY MC. GC TO PROVIDE ROOF OPENING,

FRAMING PER STRUCTURAL, AND CURB FLASHING PER

15/A506. REFER TO MECHANICAL DRAWINGS.

22 PATCH ROOF AT REMOVED ROOF CAP AND CURB

(AD102 KEYNOTE 25). INFILL DECK OPENING TO

MATCH EXISTING CONSTRUCTION. PROVIDE

INSULATION AND EPDM TO MATCH ADJACENT ROOF,

TIED INTO EXISTING PER 3/A506.

23 EXISTING ROOFTOP EQUIPMENT TO REMAIN.

PROTECT ROOF AND EQUIPMENT DURING

CONSTRUCTION.

24 NEW CANOPY ROOF: EPDM ROOFING ON EXTERIOR

SHEATHING OVER METAL DECK, SLOPED AS SHOWN.

REFER TO 4/A300, 4/A402 AND STRUCTURAL

DRAWINGS.

25 CANOPY ROOF EDGE: PHENOLIC PANEL FASCIA WITH

FASCIA COVER AND 24 GA GALVANIZED STEEL

WATERDAM PER 5/A402.

26 TIE NEW EPDM ROOFING INTO EXISTING ROOF

SYSTEM PER 3/A506 AND 12/A506.

27 NEW ROOF DRAIN AND OVERFLOW DRAIN PER

7/A506, 8/A506 AND 20/A506. RAINWATER

CONDUCTOR ROUTED TO EXTERIOR THROUGH NEW

OPENING IN EXISTING BRICK WALL (AD102 KEYNOTE

36). REFER TO ELEVATIONS. REFER TO PLUMBING

DWGS FOR ADD'L INFO.

28 NEW METAL COPING TO MATCH METAL WALL PANEL,

EXTENDED FOR NEW WALL THICKNESS, PER 2/A506.

PARAPET AT METAL PANEL PER 1/A506.

29 REINSTALL PARAPET AND ROOF MEMBRANE AT

EXISTING CANOPY ROOF

30 PROVIDE TAPERED INSULATION CRICKETS TO DIRECT

WATER TO ROOF DRAIN AND OVERFLOW DRAIN.

SLOPE 1/2" PER FOOT MIN. REFER TO 7/A506, 8/A506

AND 20/A506

53 STOP / START POINT OF METAL PANEL AT ROOF WING

WALLS

AREA OF BASE

SCOPE

KEYPLAN

PLAN

NORTH

AREA OF BASE

SCOPE

KEYPLAN

OUT OF ARCHITECTURAL SCOPE

LEGEND

S

S

S

SDSD SD SD SD

A A A

A A

8' - 0"

GWB

A

A

A

A

A

A

A 8' - 0"

ACT-2

8' - 0"

ACT-2

8' - 0"

GWB

/8

F2 F3

/8

83 90 91 92 93 94 95 96 97 98 99 100 101102 103 104

107115

A300

120.1

120.28' - 0"

ACT-1

8' - 0"

ACT-1

GREETER /

RECEPTION

OFFICE

OFFICE

COLLAB.

ADMIN

WAITING

COPY /

PRINT

MAIL

KITCHENETTE

RR

STORAGE

UTILITY

OFFICE

MOTHER'S

ROOM

RECEPTION

STORAGE

OFFICE

OFFICE

NURSES

STATION

RR

COTS

STORAGE

CORRIDOR

PACKAGES

LOST &

FOUND

8' - 6"

ACT-1

7' - 6"

ACT-1

8' - 6"

ACT-1

8' - 6"

ACT-1

8' - 6"

ACT-1

8' - 0"

ACT-1

8' - 6"

ACT-1

8' - 6"

ACT-1

8' - 6"

ACT-1

7' - 6"

ACT-1

8' - 6"

ACT-1

8' - 0"

ACT-1

8' - 0"

ACT-1

7' - 6"

GWB

7' - 0"

GWB

7' - 0"

GWB

8' - 0"

ACT-1

8' - 0"

ACT-1

8' - 6"

ACT-1

8' - 6"

ACT-1

8' - 0"

ACT-1

8' - 0"

ACT-1

7' - 6"

GWB

7' - 6"

GWB

7' - 6"

GWB

7' - 6"

ACT-1

7' - 6"

ACT-1

D8

A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1

A2

A2

A2

A2

A2

A2

A1

A1

A2

A2

A1

A1 A1 A1 A1 A1

A2 A2

A1A1

A1

A1

A2

A2

A2

A2

A2 A2 A2 A2

A2A2A2 A2A2 A2

A2A2

A1 A1 A1

A2A2

A2 A2

A2

A2A2

A2

A2A2

/4

G4

G8 G8 G8 G8

/2

A1

C1

C1 C1

4' - 2 3/4"

EQ

EQ

1' - 0 3/4"

C1

C1

C1C1

DS-2 DS-2 DS-2 DS-2

SS1

DS-3

SS1

DS-3

DS-1 DS-1 DS-1

DS-1DS-1DS-1

8' - 5"

GWB

8' - 5"

GWB

4' - 5 5/8"

A2A2

8' - 0"

ACT-1

A504

A504

SIM

31 31

34 34 34

34 34 3435

ALIGN ALIGN ALIGN

A

LI

G N

A

LI

G N

10' - 2 11/32"

GWB

14' - 5" V.I.F.

39 39

43434343

4545 45 45

4545 45 45

A504

C3

C3

C1

C3

C3

C3

C3

C3

C3

AREA OF BASE

SCOPE

1. ALL DIMENSIONS TO FINISHED FACE, UNLESS NOTED

OTHERWISE.

2. PAINT GWB CEILINGS AND UNDERSIDES OF SOFFITS

UNO.

3. ALL IN SCOPE ROOMS RECEIVE CEILING TYPE UNO.

SEE FINISH SCHEDULE AND SPECIFICATIONS FOR MORE

INFORMATION.

4. REFER TO A500 FOR CEILING TRANSITION DETAILS.

5. CEILING HEIGHTS ARE FROM THE FINISHED FLOOR.

6. CEILING TILES TO BE CENTERED IN ROOM, TYP, UNO.

7. ACT TILES SHALL NOT BE LESS THAN 4". NOTIFY ARCHITECT

OF ANY DISCREPANCIES.

8. REFER TO INTERIOR ELEVATIONS FOR MOUNTING HEIGHTS

OF WALL MOUNTED FIXTURES.

9. UNLESS NOTED OTHERWISE, CENTER ALL FIXTURES IN

CEILING TILES.

10. AT EXPOSED TO STRUCTURE PAINTED LOCATIONS:

A. COORDINATE FINAL PAINT SCOPE WITH MEP/FP

CONTRACTORS AND THE ARCHITECT.

B. PAINT SCOPE INCLUDES BUT IS NOT LIMITED TO THE

FOLLOWING ITEMS.

a. PAINT EXPOSED STRUCTURE, DECK, PIPING, DUCTS, INSULATION, LOUVERS, GRILLES, ACOUSTIC

CEILINGS, CONDUIT.

11. REFER TO MEP/FP DRAWINGS FOR ADDITIONAL

INFORMATION.

12. CENTER ALL EXIT SIGNS OVER DOOR OR OPENING, UNO.

13. COORDINATE GWB FRAMING AND GWB INSTALLATION W/

ALL MEPFP CEILING EQUIPMENT, FIXTURES, AND GRIDS.

14. ALL DIMENSIONS OF CEILING FIXTURES GIVEN TO

CENTERLINE OF FIXTURE, UNO

15. ACOUSTICAL CEILING TILE SHALL BE CENTERED IN SPACE,

AND NEVER TO HAVE A TILE CUT LESS THAN 4" WIDE

16. REFER TO ELEC DWG FOR LIGHT FIXTURE INFORMATION

17. REFER TO ELEC DWG FOR CEILING DEVICES AND

COORDINATE INSTALLATION IN ACT AND GWB CEILINGS.

18. GC TO COORDINATE WITH AV VENDOR TO PROVIDE

BLOCKING/BACKING AS NEEDED FOR MOUNTING OF

CEILING MOUNTED DEVICES (INTERIOR AND/OR EXTERIOR).

19. MECHANICAL CEILING DEVICES ARE SHOWN FOR

COORDINATION ONLY. REFER TO M101 AND M301 FOR

TYPE, SIZE, QUANTITY AND CONNECTIONS. DEVICES

SHOWN ON THE MECHANICAL DRAWINGS BUT NOT

SHOWN HERE ARE STILL INCLUDED IN THE WORK.

20. BEFORE ROUGH IN, THE MC SHALL VERIFY CLEARANCE FOR

ABOVE CEILING INFRASTRUCTURE AT CEILING HEIGHTS

SHOWN AND REPORT CONFLICTS TO ARCHITECT.

21. THE MC FURNISHES ACCESS DOORS WHEREVER CEILING

ACCESS IS REQUIRED FOR ABOVE CEILING

INFRASTRUCTURE. GC TO INSTALL. LOCATIONS TO BE

COORDINATED WITH ARCHITECT.

SHEET NOTES

ACT-1

SHEET KEYNOTES

X00 = KEYNOTE TAG

DATE ISSUED FOR

H E

C K

E N

D O

R N

S H

IL

E

S A

R C

H

IT

E C

T S e xp re s s ly r e s e rv e s i ts c o m m o n l a w c o p y ri g h t a n d o th e r p ro p e rt y r ig h ts i n t h e s e p la n s T h e s e a re n o t to b e r e p ro d u c e d n o r a re t h e y t o b e a s s ig n e d t o a n y t h ir d p a rt y w it h o u t fi rs t o b ta in in g t h e e xp re s s e d w ri tt e n c o n s e…

This is the start of the file's text. The full file is on GovTribe.