2026_09_29 Greenville Salt Shed Contract Drawings (ID 3693207).pdf
PDF 6 MB Posted
- Solicitation number
- 2139485
- Issued by
- Orange County, New York
About this file
This is a contract drawing document for the Town of Greenville, New York (Orange County), detailing the design and construction specifications for a new salt storage facility located at 1537 US Route 6, Port Jervis, New York. The project involves the construction of an approximately 8,320 square foot salt storage building with associated site work including grading, drainage, erosion control, and utility installations. The facility is designed as an 80 feet by 104 feet structure with a 14-inch concrete foundation wall (or wood barrier wall as an alternate), composite wood roof trusses, metal roofing panels, and T1-11 wall paneling. The project encompasses a 42,658 square foot (0.98 acre) limits of disturbance area. Bids for the general construction contract are due no later than 2:00 PM local time on Thursday, October 29th, 2026, with delivery to the Town of Greenville Town Clerk at the project site address. The drawings are dated September 2026 and were prepared and approved by professional engineers licensed in New York State.
The project is partially funded through a $500,000 New York State Department of Environmental Conservation (NYSDEC) Water Quality Improvement Project grant, which establishes a 30 percent Minority and Women Business Enterprise (MWBE) participation goal. MWBE-eligible firms are strongly encouraged to submit bids. The construction is designed in accordance with the 2025 Building Code of New York State and includes structural design criteria for Risk Category I occupancy with specific load requirements including roof snow loads of 53.8 PSF, basic design wind speed of 104 MPH, and seismic design parameters appropriate for the region. The facility features a design frost depth of 48 inches and an allowable soil bearing pressure of 3,000 PSF. Full contract documents and technical drawings may be obtained through the advertisement or directly from Christian Bertram, P.E., at cbertram@bartonandloguidice.com.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2026_09_29 Greenville Salt Shed Contract Documents (ID 3695388).pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet Number
Project Number
PROJECT
LOCATION
TOWN OF GREENVILLE
DAVID ZUBIKOWSKI TOWN SUPERVISOR
G001
2323.003.001
SEPTEMBER 2026
TOWN OF GREENVILLE
SALT STORAGE FACILITY
CONTRACT NO. 1 - GENERAL CONSTRUCTION
1537 US-6, PORT JERVIS
ORANGE COUNTY, NEW YORK
PROJECT LOCATION MAP
NOT TO SCALE
PREPARED AND APPROVED BY
PROFESSIONAL ENGINEERS LICENSE NO.
DATE SIGNED
EXPIRATION DATE:
NYS CERTIFICATE # 0021642, 0020588, 0019903, 0019905, 0020336
CHRISTIAN M. BERTRAM, P.E.
NEW YORK
091597 07/31/2027
DRAWING INDEX
SHEET NO. SHEET TITLE
G001 COVER SHEET
G002 GENERAL NOTES AND LEGEND
C100 EXISTING CONDITIONS AND DEMOLITION PLAN
C101 SITE LAYOUT PLAN
C102 SITE GRADING, DRAINAGE & EROSION CONTROL PLAN
C501 CIVIL DETAILS
S001 GENERAL STRUCTURAL NOTES
S101 SALT STORAGE BUILDING FOUNDATION PLAN
S102 SALT STORAGE BUILDING FRAMING PLAN
S201 SALT STORAGE BUILDING ELEVATIONS
S301 SALT STORAGE BUILDING SECTION
S302 SALT STORAGE BUILDING SECTIONS
S501 FOUNDATION DETAILS
S502 TYPICAL FRAMING DETAILS
S503 ANCHOR PLATE DETAILS
SITE ZONING STATISTICS
DISTRICT BALANCE OF TOWN
USE MUNICIPAL BUILDINGS,
STRUCTURES AND USES
SBL 7-1-27.1
OWNER TOWN OF GREENVILLE
PROPERTY
CLASS
652 - GOVERNMENT
BUILDINGS
SCHOOL
DISTRICT 333801 - MINISINK VALLEY
AREA ±209.68 AC
PREPARED AND APPROVED BY
PROFESSIONAL ENGINEERS LICENSE NO.
DATE SIGNED
EXPIRATION DATE:
CHRISTOPHER M. KWASNIEWSKI, P.E.
NEW YORK
081520 04/30/2027
SHEETS G001, G002, AND C100 - C501 SHEETS S001 - S503
09/23/2026 09/28/2026
EXISTING LEGEND:
EXISTING STRUCTURE
EXISTING EDGE OF PAVEMENT
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
EXISTING DRAINAGE DITCH CENTERLINE
EXISTING UNDERGROUND ELECTRIC LINE
EXISTING DECIDUOUS TREE
EXISTING WATER VALVE
EXISTING LIGHT POLE
PROPOSED LEGEND:
PROPOSED LIMITS OF GRAVEL REMOVAL
PROPOSED STRUCTURE
PROPOSED ASPHALT PAVEMENT
PROPOSED GRAVEL CONSTRUCTION ENTRANCE
PROPOSED TEMPORARY STOCKPILE AREA
PROPOSED TEMPORARY STONE CHECK DAM
PROPOSED DRIVEWAY CENTERLINE
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
PROPOSED LIMIT OF DISTURBANCE
PROPOSED SILT FENCE
PROPOSED UNDERGROUND ELECTRIC LINE
PROPOSED UNDERGROUND WATER SERVICE LINE
PROPOSED UNDERGROUND STORM LINE
PROPOSED EROSION CONTROL BLANKET
PROPOSED CONCRETE PAD
PROPOSED HOLDING TANK
PROPOSED NYLOPLAST CATCH BASIN
PROPOSED DRAINAGE SWALE INVERT GRADELINE
GE
N
ER
AL
N O
TE
S
AN
D
LE
GE
N D
G002
LP
R/
KM
G
CM
B
C M
B
AS SHOWN
GENERAL NOTES:
1. THE PLANS SHOW SOME KNOWN SUBSURFACE STRUCTURES, ABOVE GROUND STRUCTURES,
AND/OR UTILITIES BELIEVED TO EXIST IN THE WORKING AREA, EXACT LOCATIONS OF WHICH MAY VARY FROM THE LOCATIONS INDICATED. IN PARTICULAR, IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATION AND EXTENT OF ALL UNDERGROUND STRUCTURES AND UTILITIES PRIOR TO ANY DIGGING OR CONSTRUCTION ACTIVITIES IN THEIR VICINITY. THE CONTRACTOR SHALL HAVE ALL THE EXISTING UTILITIES FIELD STAKED BEFORE STARTING WORK BY CALLING 1-800-962-7962.
2. ALL WORK SHALL BE DONE IN STRICT CONFORMANCE WITH APPLICABLE NATIONAL, STATE, AND
LOCAL CODES, PERMITS, STANDARDS, ORDINANCES, RULES, AND REGULATIONS.
3. ALL TRENCH EXCAVATION AND ANY REQUIRED SHEETING AND SHORING SHALL BE DONE IN
ACCORDANCE WITH THE LATEST REVISIONS OF NEW YORK STATE INDUSTRIAL CODE RULE 23 AND OSHA REGULATIONS FOR CONSTRUCTION. SHEET PILING SHALL BE DESIGNED AND SEALED BY A NEW
YORK STATE PROFESSIONAL ENGINEER.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR DEWATERING AND THE MAINTENANCE OF SURFACE
DRAINAGE DURING THE COURSE OF WORK.
5. THE CONTRACTOR SHALL RESTORE LAWNS, DRIVEWAYS, CULVERTS, SIGNS, AND OTHER PUBLIC OR
PRIVATE PROPERTY DAMAGED OR REMOVED TO AT LEAST AS GOOD AS CONDITION AS BEFORE
BEING DISTURBED AS DETERMINED BY THE ENGINEER. ANY DAMAGED TREES, SHRUBS, AND OR
HEDGES SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE.
6. CONTRACTOR SHALL MAINTAIN FLOW FOR ALL EXISTING UTILITIES. CONTRACTOR SHALL ALSO TAKE ALL NECESSARY STEPS AND PRECAUTIONS DURING CONSTRUCTION TO PROTECT ALL NEIGHBORING
AND DOWNSTREAM PROPERTIES FROM FLOODING OR OTHER CONSTRUCTION-RELATED DAMAGE.
7. ALL ASPHALT PAVEMENT RESTORATION SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR.
8. CONTRACTOR SHALL KEEP THE WORK AREA CLEAN ON A DAILY BASIS.
9. TRAFFIC CONTROL AND DEVICES TO BE PROVIDED AND MAINTAINED BY THE CONTRACTOR. THE
CONTRACTOR SHALL NOTIFY THE TOWN 48 HOURS IN ADVANCE OF ANY WORK. THE CONTRACTOR
SHALL NOT WORK OR EXECUTE ANY PORTION OF THIS PROJECT IF PROPER TRAFFIC CONTROL IS NOT
PRESENT.
10. THE CONTRACTOR SHALL NOT LEAVE OPEN ANY HOLES OR TRENCHES OVERNIGHT OR DURING ANY
TIME NOT ACTIVELY WORKING ON THE PROJECT.
11. REFER TO STRUCTURAL DRAWINGS FOR PRECISE BUILDING DIMENSIONS.
12. THE ENGINEER SHALL BE NOTIFIED IN WRITING OF ANY CONDITIONS THAT VARY FROM THOSE
SHOWN ON THE PLANS. THE CONTRACTORS WORK SHALL NOT VARY FROM THE PLANS WITHOUT
THE EXPRESSED APPROVAL FROM THE ENGINEER.
13. IN ALL TRENCH EXCAVATIONS, CONTRACTOR MUST LAY THE TRENCH SIDE SLOPES BACK TO A SAFE SLOPE, USE A TRENCH SHIELD, OR PROVIDE SHEETING AND BRACING. THE MEANS AND METHODS
SHALL BE CERTIFIED BY A PROFESSIONAL ENGINEER.
14. IF SUSPICIOUS AND/OR HAZARDOUS MATERIAL IS ENCOUNTERED DURING
DEMOLITION/CONSTRUCTION, ALL WORK SHALL STOP AND THE ORANGE COUNTY HEALTH
DEPARTMENT AND THE NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION
SHALL BE NOTIFIED IMMEDIATELY. WORK SHALL NOT RESUME UNTIL THE DEVELOPER HAS
OUTLINED APPROPRIATE ACTION FOR DEALING WITH THE WASTE MATERIAL AND THE
DEVELOPMENT PLANS ARE MODIFIED AS MAY BE NECESSARY.
15. EXCAVATED WASTE MATERIAL REMOVED FROM THE SITE SHALL BE PLACED AT A LOCATION
ACCEPTABLE TO THE NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION.
16. ALL EXISTING SURFACE APPURTENANCES (I.E. WATER VALVES, CATCH BASIN FRAMES AND GRATES, MANHOLE COVERS) WITHIN THE PROJECT LIMITS SHALL BE ADJUSTED TO FINISHED GRADE. AREAS DISTURBED OR DAMAGED AS PART OF THIS PROJECT'S CONSTRUCTION THAT ARE OUTSIDE OF THE PRIMARY WORK AREA SHALL BE RESTORED, AT THE CONTRACTOR'S EXPENSE, TO THE SATISFACTION
OF THE OWNER'S REPRESENTATIVE.
17. UNLESS COVERED BY CONTRACT SPECIFICATIONS OR AS NOTED ON THE PLANS, ALL WORK SHALL
CONFORM TO THE NEW YORK STATE DEPARTMENT OF TRANSPORTATION STANDARD
SPECIFICATIONS DATED JANUARY 1, 2024 AND ANY SUBSEQUENT REVISIONS.
18. MISCELLANEOUS WORK NOT SPECIFICALLY SHOWN ON THE CONTRACT DRAWINGS SUCH AS
PATCHING, BLOCKING, TRIMMING, ETC. SHALL BE PERFORMED AS REQUIRED TO MAKE THE WORK
COMPLETE.
THE CONTRACTOR SHALL:
18.1. VERIFY ALL CONDITIONS IN THE FIELD PRIOR TO COMMENCEMENT OF WORK AND NOTIFY THE
ENGINEER OF ANY DISCREPANCIES.
18.2. EXAMINE THE SITE AND INCLUDE IN HIS/HER WORK THE EFFECT OF ALL EXISTING CONDITIONS
OF THE WORK
18.3. PROVIDE AND INSTALL ALL MATERIALS AND PERFORM ALL WORK IN ACCORDANCE WITH THE
RECOGNIZED GOOD STANDARD PRACTICE.
GRADING NOTES
1. OWNER WILL ROUGH GRADE BUILDING PAD AREA TO FINISH GRADE ±6 INCHES.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORATION OF GRADE TO ALL DISTURBED AREAS.
IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN EROSION CONTROL MEASURES AT ALL
TIMES.
3. ALL INLETS TO THE STORM SEWER SHALL HAVE STONE DROP INLET PROTECTION PROVIDED BY THE
OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE BEST MANAGEMENT
PRACTICES (BMP'S) UNTIL GROUND COVER IS ESTABLISHED.
4. SILT FENCE, JUTE MESH, AND/OR EROSION CONTROL BLANKETS WILL BE USED ON SLOPES STEEPER
THAN 3:1 AND WHEREVER NECESSARY TO CONTROL EROSION AND SILTATION OF EXISTING
DRAINAGE SYSTEMS AS ORDERED BY THE ENGINEER OR SPECIFIED ON PLANS.
5. THE CONTRACTOR SHALL DESIGNATE A TRAINED MEMBER OF HIS/HER FIRM TO BE RESPONSIBLE TO
MONITOR EROSION CONTROL, EROSION CONTROL STRUCTURES, TREE PROTECTION AND
PRESERVATION THROUGHOUT CONSTRUCTION IN ACCORDANCE WITH THE APPROVED STORM
WATER POLLUTION PREVENTION PLAN (SWPPP).
6. ALL DISTURBED AREAS SHALL BE PROTECTED FROM EROSION EITHER BY MULCH OR TEMPORARY
SEEDING WITHIN 14 DAYS OF DISTURBANCE.
7. SLOPE SIDES OR EXCAVATIONS TO COMPLY WITH ALL LOCAL CODES AND ORDINANCES HAVING JURISDICTION. MAINTAIN SIDES AND SLOPES OF EXCAVATIONS IN A SAFE CONDITION UNTIL THE COMPLETION OF BACKFILLING. BACKFILL EXCAVATION AS PROMPTLY AS WORK PERMITS, BUT NOT
WITHOUT ACCEPTANCE BY ENGINEER OF CONSTRUCTION BELOW FINISH GRADE.
8. PLACE BACKFILL AND FILL MATERIALS IN LAYERS NOT MORE THAN 8" IN LOOSE DEPTH. FILL MATERIAL SHALL BE FREE FROM DEBRIS, VEGETATION, AND DELETERIOUS MATERIAL. COMPACT ALL
TRENCH BACKFILL TO 95% STANDARD PROCTOR.
9. GRAVEL AND SUB-BASE SHALL BE LAID IN 6" LIFTS AND SHALL CONFORM TO THE TYPICAL SECTION FOR PAVEMENT. ALL HOLES AND DEPRESSIONS SHALL BE FILLED WITH GRAVEL AND RE-ROLLED.
WM WM
SS
E E E
ABBREVIATIONS:
AAD AUTOMATIC AIR DAMPER
ACT ACOUSTICAL CEILING TILE
ALUM ALUMINUM
BLDG BUILDING
BSMT BASEMENT
BOT BOTTOM
BUR BUILT UP ROOF
CB CATCH BASIN
C/C CENTER TO CENTER
CCTV CLOSED CIRCUIT TELEVISION
CFM CUBIC FEET PER MINUTE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNITS
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
CPP CORRUGATED POLYETHYLENE PIPE
CPT CARPET
CT CERAMIC TILE
DEMO DEMOLISH, DEMOLITION
DN DOWN
DS DOWNSPOUT
DTL DETAIL
DWG DRAWING
E.F. EACH FACE
E.W. EACH WAY
EA EACH
EC ELECTRICAL CONTRACTOR
ELEC ELECTRICAL
ELEV ELEVATION
EMBED EMBEDMENT
EPS EXPANDED POLYSTYRENE
EQUIP EQUIPMENT
E.S.P EXTERNAL STATIC PRESSURE
EW EACH WAY
EXP EXPOSED
EXP ANCHOR EXPANSION ANCHOR
EXT EXTERIOR
EX, EXIST EXISTING
FIN FLR FINISHED FLOOR
FLA FULL LOAD AMPS
FND FOUNDATION
FPM FEET PER MINUTE
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
HBD HARDBOARD
HC HANDICAP
HM HOLLOW METAL
HP HORSE POWER
HZ HERTZ
INSUL NSULATION
IGU INSULATED GLASS UNIT
INV INVERT
JT JOINT
L ANGLE
LAM LAMINATE
MANUF MANUFACTURER
MAS MASONRY
MAX MAXIMUM
MC MECHANICAL CONTRACTOR
MIN MINIMUM
MR MOISTURE RESISTANT
MTL METAL
MO MASONRY OPENING
NAT NATURAL
NIC NOT IN CONTRACT
NTS NOT TO SCALE
O/C ON CENTER
OD OUTSIDE DIAMETER
PEMB PRE-ENGINEERED METAL BUILDING
PERF PERFORATED
PL PLATE
PLAS PLASTIC
PLYWD PLYWOOD
PNT PAINT
PT PRESSURE TREATED
PPT PRESSURE PRESERVATIVE TREATED
PVMT PAVEMENT
QT QUARRY TILE
R RISER
RD ROOF DRAIN
RAD RADIUS
REQ'D REQUIRED
RO ROUGH OPENING
SC SOLID CORE
SAN SANITARY
SHT SHEET
SIM SIMILAR
SQ SQUARE
SS STAINLESS STEEL
STL STEEL
SUS SUSPENDED
SV SHEET VINYL
T TREAD
T/ TOP OF
T&B TOP AND BOTTOM
TEMP TEMPERED
TYP TYPICAL
VCT VINYL COMPOSITION TILE
VIF VERIFY IN FIELD
W.G WATER GAUGE
NYS EXP.:
N
YS
C
ER
TI
FI
CA
TE
6, 8, 3, , 0
07/31/2027
Sheet Number
Project Number
Ch ec ke d by Dr aw n by De sig ne d by
In c ha rg e of
Scale
Date
TO
W
N O
F
GR
EE
N
VI
LL
E
SA
LT
S
TO
RA
GE
F
AC
IL
IT
Y
TO
W
N O
F
GR
EE
N
VI
LL
E O
RA
N
GE
C
O U
N
TY
, N
EW
Y O
RK
SEPTEMBER 2026
2323.003.001
CM
B
REVISIONS
LIMITS OF
DISTURBANCE: ±42,658
SFT ±0.98 AC
W
E E
E E
E E
E E
E
EXISTING UNDERGROUND ELECTRIC LINE
TO REMAIN. TOWN TO VERIFY THE
LOCATION, PRIOR TO CONSTRUCTION.
EXISTING ONSITE WELL
TO REMAIN AND PROTECTED
DURING CONSTRUCTION
EXISTING
GRAVEL TO BE
REMOVED BY
TOWN
EXISTING UTILITY LIGHT POLE BE
DE-ENERGIZED BY ELECTRICAL
CONTRACTOR (EC)
GENERAL CONTRACTOR (GC) TO
REMOVE AND RELOCATE NYS EXP.:
N
YS
C
ER
TI
FI
CA
TE
6, 8, 3, , 0
07/31/2027
Sheet Number
Project Number
Ch ec ke d by Dr aw n by De sig ne d by
In c ha rg e of
Scale
Date
TO
W
N O
F
GR
EE
N
VI
LL
E
SA
LT
S
TO
RA
GE
F
AC
IL
IT
Y
TO
W
N O
F
GR
EE
N
VI
LL
E O
RA
N
GE
C
O U
N
TY
, N
EW
Y O
RK
2323.003.001
CM
B
REVISIONS
TRUENORTH
20' 1"=20'
0 20' 40'
NYS EXP.:
N
YS
C
ER
TI
FI
CA
TE
6, 8, 3, , 0
Sheet Number
Project Number
Ch ec ke d by Dr aw n by De sig ne d by
In c ha rg e of
Scale
Date
TO
W
N O
F
GR
EE
N
VI
LL
E
SA
LT
S
TO
RA
GE
F
AC
IL
IT
Y
TO
W
N O
F
GR
EE
N
VI
LL
E O
RA
N
GE
C
O U
N
TY
, N
EW
Y O
RK
SEPTEMBER 2026
2323.003.001
REVISIONS
TRUENORTH
20' 1"=20'
0 20' 40'
EX
IS
TI
N
G
CO
N
DI
TI
O
N S
AN
D
DE
M
O
LI
TI
O
N P
LA
N
C100
LP
R/
KM
G
CM
B
C
B
AS SHOWN
R90'
R50'
R20'
R20'R20'R25'
NEW ASPHALT
PAVEMENT BY
TOWN
PROPOSED DRAINAGE
SWALE BY TOWN
PROPOSED DRAINAGE
SWALE BY TOWN
PROPOSED UNDERGROUND
ELECTRIC BY TOWN
NEW 80' x 104'
SALT SHED BY
GENERAL
CONTRACTOR
(8,320 SFT)
SNOW
STORAGE
AREA
R10'
R10'
R20'
S
S2,000 GALLON
HOLDING TANK
INV: 932.63
BY TOWN STORM INLET #1
10" NYLOPLAST
DRAIN BASIN BY TOWN
TF: 934.50
INV: 933.25
31 LFT 6" PVC
SDR35 @ 2%
W
PROPOSED 1" HDPE SDR 11
WATER SERVICE BY TOWN
E E
E E
E E
E E
E
WM
W M
W M
STORM INLET #2
10" NYLOPLAST
DRAIN BASIN BY TOWN
TF: 934.50
INV: 933.25
6" PVC
INV 932.01
59 LFT 6" PVC
SDR35 @ 2.10%
BY TOWN
8"-THICK HEAVY-DUTY
CONCRETE WASH PAD BY TOWN
OPTIONAL PARKING LOT LIGHTING
STANDARD WITH CONCRETE BASE. BASES
TO BE INSTALLED BY BY TOWN. LIGHTS
AND WIRING TO BE INSTALLED BY TOWN.
(TYP OF 3)
20'
60'
20'
64' 104'
80'
20'
30'
20'
PROPOSED STEEL
AND CONCRETE
BOLLARD (TYP)
BY TOWN
EXISTING GARAGE
OPTIONAL UNDERGROUND
BY TOWN
31 LFT 8" PVC
SDR35 @ 0.50%
BY TOWN
8" PVC
INV 918.558" PVC
INV 918.40
PROPOSED UNDERGROUND ELECTRIC
TO HIGH WATER ALARM BY TOWN NEW ASPHALT PAVEMENT
AND SUB BASE INSIDE OF
BUILDING BY TOWN
NYS EXP.:
N
YS
C
ER
TI
FI
CA
TE
6, 8, 3, , 0
07/31/2027
Sheet Number
Project Number
Ch ec ke d by Dr aw n by De sig ne d by
In c ha rg e of
Scale
Date
TO
W
N O
F
GR
EE
N
VI
LL
E
SA
LT
S
TO
RA
GE
F
AC
IL
IT
Y
TO
W
N O
F
GR
EE
N
VI
LL
E O
RA
N
GE
C
O U
N
TY
, N
EW
Y O
RK
SEPTEMBER 2026
2323.003.001
CM
B
REVISIONS
TRUENORTH
20' 1"=20'
0 20' 40'
SI
TE
L
AY
O U
T
PL
AN
C101
LP
R/
KM
G
CM
B
C
B
AS SHOWN
SCOPE OF WORK BY
GENERAL CONTRACTOR
('BASE BID' AS INDICATED ON THESE
DRAWINGS. 'ALTERNATE' BASED ON THESE
DRAWINGS AS MODIFIED IN SECTION 13 37 00.)
0+
0+
1+00
1+50
2+00 2+50
3+00 3+50
4+00 4+06
LIMITS OF
DISTURBANCE: ±42,658
SFT ±0.98 AC
NEW 80' x 104'
SALT SHED BY
GENERAL
CONTRACTOR
(8,320 SFT)
PROPOSED SILT
FENCE (TYP) BY
TOWN
MATCH LINE
AND GRADE
PROVIDE EROSION CONTROL BLANKET
OR JUTE MESH ON ALL SLOPES 1:3 OR
GREATER (TYP) BY TOWN
PROPOSED 75' GRAVEL
CONSTRUCTION ENTRANCE
BY TOWN
MATCH LINE
AND GRADE
PROPOSED TEMPORARY
STOCKPILE LOCATION
BY TOWN
PROPOSED SILT
FENCE (TYP) BY
TOWN
STONE CHECK
DAM (TYP) BY
TOWN
S S
W
E E
E E
E E
E E
E
WM
W M
W M
935.40
935.25
935.50
935.50
934.80
934.20
933.80
934.54935.00
935.00 935.00
934.50
935.00934.61
935.35
935.50
935.13
933.89
932.94
930.61
930.29
932.78
924.64
924.24
919.31
919.07
933.43 933.48
935.50
935.50
935.40
935.15
934.47
934.55 934.47
929931
0+
0+
1+00
1+50
2+00 2+50
3+00 3+50
4+00 4+06
DRIVEWAY
CENTERLINE
(SEE PROFILE)
7.
6%
918.55
918.40
NYS EXP.:
N
YS
C
ER
TI
FI
CA
TE
6, 8, 3, , 0
07/31/2027
Sheet Number
Project Number
Ch ec ke d by Dr aw n by De sig ne d by
In c ha rg e of
Scale
Date
TO
W
N O
F
GR
EE
N
VI
LL
E
SA
LT
S
TO
RA
GE
F
AC
IL
IT
Y
TO
W
N O
F
GR
EE
N
VI
LL
E O
RA
N
GE
C
O U
N
TY
, N
EW
Y O
RK
SEPTEMBER 2026
2323.003.001
CM
B
REVISIONS
TRUENORTH
20' 1"=20'
0 20' 40'
SI
TE
G
RA
DI
N
G, D
RA
IN
AG
E
AN
D
EO
RO
SI
O
N C
O N
TR
O
L
PL
AN
C102
LP
R/
KM
G
CM
B
C
B
AS SHOWN
SCOPE OF WORK BY
GENERAL CONTRACTOR
('BASE BID' AS INDICATED ON THESE DRAWINGS.
'ALTERNATE' BASED ON THESE DRAWINGS AS
MODIFIED IN SECTION 13 37 00.)
NYS EXP.:
N
YS
C
ER
TI
FI
CA
TE
6, 8, 3, , 0
07/31/2027
Sheet Number
Project Number
Ch ec ke d by Dr aw n by De sig ne d by
In c ha rg e of
Scale
Date
TO
W
N O
F
GR
EE
N
VI
LL
E
SA
LT
S
TO
RA
GE
F
AC
IL
IT
Y
TO
W
N O
F
GR
EE
N
VI
LL
E O
RA
N
GE
C
O U
N
TY
, N
EW
Y O
RK
SEPTEMBER 2026
2323.003.001
CM
B
REVISIONS
CI
VI
L
DE
TA
IL
S
C501
LP
R
CM
B
C M
B
AS SHOWN
CONCRETE WASHOUT NOTES:
1. LOCATE WASHOUT FACILITY ON FLAT GRADE A MINIMUM OF 50 FEET AWAY FROM OPEN
CHANNELS, STORM DRAIN INLETS, SENSITIVE AREAS, WETLANDS, BUFFERS AND WATER COURSES
AND AWAY FROM CONSTRUCTION TRAFFIC.
2. SIZE WASHOUT FACILITY FOR VOLUME NECESSARY TO CONTAIN WASH WATER AND SOLIDS AND MAINTAIN AT LEAST 4 INCHES OF FREEBOARD. TYPICAL DIMENSIONS ARE 10 FEET X 10 FEET X 3
FEET DEEP.
3. COMPOST FILTER SOCKS MAY BE DIRECT SEEDED AT TIME OF INSTALLATION.
4. PROVIDE A SIGN FOR THE WASHOUT IN CLOSE PROXIMITY TO THE FACILITY.
5. INSPECT WASHOUT DAILY. KEEP PRACTICE WATER TIGHT. EMPTY OR REPLACE WASHOUT
STRUCTURE THAT IS 50 PERCENT FULL, AND DISPOSE OF ACCUMULATED MATERIAL PROPERLY. DO
NOT REUSE COMPOST FILTER SOCKS. WET-VACUUM STORED LIQUIDS THAT HAVE NOT
EVAPORATED AND DISPOSE OF IN AN APPROVED MANNER. PRIOR TO FORECASTED RAINSTORMS,
REMOVE LIQUIDS OR COVER STRUCTURE TO PREVENT OVERFLOWS. REMOVE HARDENED SOLIDS,
WHOLE OR BROKEN UP, FOR DISPOSAL OR RECYCLING. MAINTAIN RUNOFF DIVERSION AROUND
EXCAVATED WASHOUT STRUCTURE UNTIL STRUCTURE IS REMOVED.
6. ALTERNATIVE CONSTRUCTION USING STRAW BALES AND 10 MIL OR THICKER UV RESISTANT, IMPERMEABLE SHEETING MAY BE APPROVED BY ENGINEER PRIOR TO INSTALLATION
GRADE
TEMPORARY PLASTIC BARRIER FENCE NOTES:
1. TEMPORARY PLASTIC BARRIER FENCE IS INTENDED TO PROTECT SENSITIVE SITE FEATURES. INSTALL FENCE AT THE LOCATIONS SHOWN ON PLANS
OR WHERE DIRECTED BY THE ENGINEER PRIOR TO COMMENCEMENT OF CONSTRUCTION.
2. SPACE WARNING SIGNS A MINIMUM OF ONE EVERY 300 FEET. THE SIZE OF EACH SIGN MUST BE A MINIMUM OF 1.5' x 2' WITH 4" BLACK
LETTERS ON A WHITE BACKGROUND. THE SIGN MUST CONTAIN THE FOLLOWING LANGUAGE:
"PROTECTED AREA - KEEP OUT"
3. THERE SHALL BE NO STORAGE OF MATERIAL WITHIN THE BOUNDARIES OF THE PROTECTED AREA FENCING.
4. TEMPORARY PROTECTION AREA FENCING SHALL BE MAINTAINED THROUGHOUT THE DURATION OF THE PROJECT.
5. ALL MATERIALS REQUIRED TO FURNISH AND INSTALL THE FENCING AND WARNING SIGNS AS DETAILED ON THE PLANS AND AT THE DIRECTION
OF THE ENGINEER SHALL BE PAID FOR UNDER THE UNIT PRICE BID ITEM.
ATTACH SIGN TO POST UV-STABILIZED HDPE MESH
HIGH-VISIBILITY ORANGE
4'-0" C/C
MIN.
4'-0"
MIN.
2'-0"
MIN.
RIGID METAL OR WOOD POSTS
DUST CONTROL NOTES:
TEMPORARY METHODS:
1. MULCHES: IN ACCORDANCE WITH THE APPROVED SWPPP.
2. VEGETATIVE COVER: IN ACCORDANCE WITH THE APPROVED SWPPP.
3. ADHESIVES: USE ON MINERAL SOILS ONLY (NOT EFFECTIVE ON MUCK SOILS). KEEP TRAFFIC OFF THESE
AREAS. THE FOLLOWING TABLE MAY BE USED FOR GENERAL GUIDANCE.
TYPE OF WATER TYPE OF APPLY
EMULSION DILUTION NOZZLE GAL/AC.
LATEX EMULSION 12.5:1 FINE SPRAY 235
RESIN-IN-WATER EMULSION 4.1 FINE SPRAY 300
ACRYLIC EMULSION (NON-TRAFFIC) 7:1 COARSE SPRAY 450
ACRYLIC EMULSION (TRAFFIC) 3.5:1 COARSE SPRAY 350
4. TILLAGE: FOR EMERGENCY TEMPORARY TREATMENT, SCARIFY THE SOIL SURFACE TO PREVENT OR
REDUCE THE AMOUNT OF BLOWING DUST UNTIL A MORE APPROPRIATE SOLUTION CAN BE
IMPLEMENTED. BEGIN THE TILLAGE OPERATION ON THE WINDWARD SIDE OF THE SITE USING A
CHISEL-TYPE PLOW FOR BEST RESULTS.
5. SPRINKLING: SPRINKLE SITE WITH WATER UNTIL THE SURFACE IS MOIST. REPEAT AS NEEDED.
6. CALCIUM CHLORIDE: APPLY AS FLAKES OR GRANULAR MATERIAL WITH A SPREADER AT A RATE THAT
WILL KEEP THE SOIL SURFACE MOIST. RE-APPLY AS NECESSARY.
7. BARRIERS: PLACE BARRIERS SUCH AS SOLID BOARD FENCES, SNOW FENCES, HAY BALES, ETC. AT RIGHT
ANGLES TO THE PREVAILING AIR CURRENTS AT INTERVALS OF APPROX. 10X THEIR HEIGHT.
PERMANENT METHODS:
8. VEGETATIVE COVER: IN ACCORDANCE WITH THE APPROVED SWPPP.
9. STONE: APPLY LAYER OF CRUSHED STONE OR COARSE GRAVEL TO PROTECT SOIL SURFACE.
2"x2"x36" WOODEN
STAKE AT 5' O.C. STACKED 18" DIA.
COMPOST FILTER SOCK
MAX. DEPTH OF CONTAMINATED
WATER IS 50% OF STACKED FILTER
RING HEIGHT
PUMP CONTAMINATED WATER
INTO CONCRETE WASHOUT
STACKED 18" DIA.
COMPOST FILTER SOCK
2"x2"x36" WOODEN
STAKE AT 5' O.C.
12" MIN.
EXIST. GRADE
PLASTIC BARRIER FENCE
NOT TO SCALE1
CONCRETE WASHOUT
NOT TO SCALE
DUST CONTROL
NOT TO SCALE
NYSDEC SIGNAGE
NOT TO SCALE
MATERIALS, SIZE, AND COLORS:
· SIZE: HORIZONTAL FORMAT 48" WIDE BY 24" TALL.
· CONSTRUCTION MATERIALS: ALUMINUM BLANK SIGN BOARDS WITH VINYL SHEETING.
· COLOR SCHEME:
· TYPE SPECIFICATIONS:
· PRODUCTION NOTES: 48" WIDE X 24" TALL ALUMINUM BLANKS WILL BE COVERED WITH VINYL SHEETING FOR APPLICATION OF
ARTWORK. ARTWORK WILL BE SILK SCREENED ON THIS SURFACE.
· BACKGROUND - PMS288C
· BUILDING TODAY FOR A BETTER TOMORROW" GRAPHIC:
· NYS/DEC LOGO - WHITE
· "FUNDING FOR THIS PROJECT PROVIDED BY A CWIA/EPF WATER QUALITY IMPROVEMENT PROJECT GRANT" GRAPHIC - PMS130C
· "KATHY HOCHUL, GOVERNOR" AND "AMANDA LEFTON, COMMISSIONER" GRAPHICS - WHITE
· TEXT: PROJECT APPLICANT AND PROJECT NAME - WHITE
· RECTANGULAR BEAM - PMS130C
· HOOKS - WHITE
· TEXT "BUILDING TODAY FOR" - PMS288C
· TEXT "A BETTER TOMORROW" - WHITE
· ALL TYPE IS PROXIMA NOVA BOLD.
· FORMAT IS: CENTER EACH LINE OF COPY WITH TITLE CASE CAPITALIZATION.
INSTALLATION:
· THE SIGN SHALL BE INSTALLED WITHIN 1 WEEK OF COMMENCEMENT OF WORK.
· THE SIGN SHALL BE ERECTED IN A PROMINENT LOCATION AND SECURED FROM VANDALISM.
· SIGN MUST BE MAINTAINED FOR AT LEAST 1 YEAR AFTER CONSTRUCTION COMPLETION AND
· REMAIN PLUMB, LEVEL, AND IN GOOD CONDITION.
CONTENT:
· PDF FILES TO BE PROVIDED TO CONTRACTOR FOR PRINTING.
· THE SIGN SHALL BE FABRICATED BY A PROFESSIONAL SIGN MANUFACTURER.
· LETTERING AND STRIPING SHALL BE UNIFORM WITH SHARP, NEAT PROFILES.
· THE SIZE OF TEXT AND LOGOS MUST BE PROPORTIONAL TO THAT SHOWN ON THE SIGN TEMPLATE.
TOWN OF GREENVILLE
AMANDA LEFTON, COMMISSIONER
SALT STORAGE FACILITY
TOWN OF GREENVILLE
STRUCTURAL DESIGN CRITERIA:
ALL STRUCTURES ARE DESIGNED IN ACCORDANCE WITH THE 2025 BUILDING CODE OF NEW YORK STATE (BCNYS)
DESIGN LOADS:
RISK CATEGORY: I
FLOOR LIVE LOADS: N/A
ROOF LIVE LOADS:
MINIMUM ROOF LIVE LOAD 20 PSF
ROOF TRUSS LOADS:
TOP CHORD DEAD LOADS 10 PSF
BOTTOM CHORD DEAD LOADS 5 PSF
BOTTOM CHORD COLLATERAL LOADS 5 PSF
ROOF SNOW LOAD DATA:
GROUND SNOW LOAD, pg = 64 PSF ALLOWABLE STRESS DESIGN GROUND SNOW LOAD, Pg(asd) = 44.8 PSF SNOW EXPOSURE FACTOR, Ce = 1.0 THERMAL FACTOR, Ct = 1.20 FLAT ROOF SNOW LOAD, pf = 53.8 PSF SLOPE FACTOR, Cs = 1.00 SLOPED ROOF SNOW LOAD, pS = 53.8 PSF
SNOW DRIFTS: N/A
WINTER WIND PARAMETER FOR SNOW DRIFT, w2 = 0.55
ROOF RAIN LOAD DATA:
RAIN INTENSITY: 15-MINUTE PRECIPITATION i = 6.37 IN/HR
60-MINUTE PRECIPITATION i = 2.8 IN/HR
WIND DESIGN DATA:
BASIC DESIGN WIND SPEED, V = 104 MPH
ALLOWABLE STRESS DESIGN WIND SPEED, Vasd = 81 MPH
WIND EXPOSURE CATEGORY: C
INTERNAL PRESSURE COEFFICIENT, GCPI = +/- 0.018
DESIGN WIND PRESSURES FOR COMPONENTS AND CLADDING:
(NOTES: NEGATIVE VALUES INDICATE LOADS AWAY FROM SURFACE)
ROOF:
TYPICAL: 8.0 PSF / -45.5 PSF
EDGES: 8.0 PSF / -45.5 PSF
CORNERS: 8.0 PSF / -70.4 PSF
WALL:
TYPICAL: 20.5 PSF / -23.0 PSF
CORNERS: 20.5 PSF / -30.8 PSF
EARTHQUAKE DESIGN DATA:
SEISMIC IMPORTANCE FACTOR, Ie = 1.00
MAPPED SPECTRAL RESPONSE ACCELERATION PARAMETERS: SS = 0.21
S1 = 0.046
SITE CLASS: C
DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS: SDS = 0.14
SD1 = 0.04
SEISMIC DESIGN CATEGORY, SDC:
BASIC SEISMIC FORCE-RESISTING SYSTEM:
BUILDING FRAME SYSTEM: LIGHT-FRAME WALLS WITH SHEAR PANELS
ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL FORCE PROCEDURE
SEISMIC RESPONSE COEFFICIENT, CS = 0.056
RESPONSE MODIFICATION COEFFICIENT, R = 2.5
DESIGN BASE SHEAR: V = 3.263 KIPS
GEOTECHNICAL DESIGN DATA:
DESIGN FROST DEPTH: 48 INCHES
DESIGN SOIL LOAD-BEARING PRESSURE: 3,000 PSF
CONCRETE NOTES (REFERENCE DIVISION 03 SPECIFICATIONS):
1. ALL CONCRETE SHALL BE BATCHED, TRANSPORTED, CONVEYED, PLACED, CURED, AND TESTED IN ACCORDANCE WITH ACI 301, ACI 318, AND CHAPTER 19 OF THE BUILDING CODE, AND AS SPECIFIED HEREIN.
2. CONCRETE MIX DESIGNS:
a. ALL GENERAL USE CONCRETE SHALL BE AIR ENTRAINED AND HAVE A MINIMUM 28-DAY COMPRESSIVE
STRENGTH OF 5,000 PSI, UNLESS INDICATED OTHERWISE.
3. CONCRETE REINFORCEMENT:
a. ALL REINFORCING STEEL BARS SHALL BE ASTM A615, GRADE 60 DEFORMED BARS.
b. TYPICAL REINFORCING BAR SPLICED LAP LENGTHS SHALL BE AS SHOWN IN THE "REINFORCING BAR LAP
SPLICE LENGTHS" TABLE ON THIS SHEET.
c. WELDED WIRE REINFORCEMENT (WWR) SHALL BE SUPPLIED IN FLAT SHEETS CONFORMING TO ASTM
A1064. LAP SPLICE WWR SHEETS MINIMUM 6 INCHES.
d. CLEAR CONCRETE COVER OVER REINFORCING BARS SHALL CONFORM TO THE REQUIREMENTS OF ACI
318 AND AS FOLLOWS:
- CONCRETE EXPOSED TO EARTH, WEATHER, OR WATER: 2"
- CONCRETE CAST DIRECTLY AGAINST EARTH: 3"
- BEAMS & COLUMNS/PIERS - TIES & STIRRUPS: 1 1/2"
PRIMARY REINFORCEMENT: 2"
4. CONCRETE FORMING AND PLACEMENT:
a. ALL EXPOSED EDGES OF CONCRETE MEMBERS SHALL BE FORMED WITH A 3/4" BY 3/4" CHAMFER, INCLUDING TOP EDGES AND OUTSIDE VERTICAL CORNERS OF WALLS, SLABS, BEAMS, COLUMNS, ETC.
b. APPLY BONDING AGENT PRIOR TO CASTING CONCRETE AGAINST HARDENED CONCRETE, UNLESS
INDICATED OTHERWISE.
c. CONTRACTOR SHALL PROVIDE CONSTRUCTION JOINTS AND CONTROL JOINTS AS INDICATED ON THESE DRAWINGS. CONTRACTOR MAY PROPOSE ADDITIONAL CONSTRUCTION JOINTS NEEDED TO FACILITATE CONSTRUCTION. ALL ADDITIONAL CONSTRUCTION JOINTS SHALL BE APPROVED BY THE STRUCTURAL
ENGINEER PRIOR TO CONSTRUCTING.
d. CONTRACTOR SHALL COORDINATE ALL WALL AND SLAB PENETRATIONS AND OPENINGS WITH OTHER TRADES. NOTE THAT NOT ALL PENETRATIONS AND OPENINGS ARE INDICATED ON THESE STRUCTURAL
DRAWINGS.
e. CONTRACTOR SHALL COORDINATE THE CASTING-IN OF ALL EMBEDDED ITEMS AND ACCESSORIES OF
ALL TRADES. POST-INSTALLATION OF EMBEDDED ITEMS WILL NOT BE ACCEPTED.
5. CONCRETE FINISHES AND CURING:
a. ALL EXPOSED FACES OF CONCRETE SHALL BE RUBBED FINISH (UNLESS NOTED OTHERWISE).
b. CONCRETE SHALL BE CURED AS SPECIFIED IN SECTION 03 30 00.
c. ALL STRUCTURAL CONCRETE SHALL ATTAIN THE SPECIFIED CONCRETE STRENGTH PRIOR TO INDUCING
LOAD.
6. NON-SHRINK GROUT SHALL BE FLOWABLE, NON-STAINING, CEMENT-BASED PRODUCT THAT IS
MANUFACTURED PREMIXED REQUIRING ONLY THE ADDITION OF WATER. GROUT SHALL BE CAPABLE OF ACHIEVING 5,000 PSI IN 7 DAYS AND 7,000 PSI IN 28 DAYS MIXED AT A PLASTIC CONSISTENCY.
7. CHEMICAL ADHESIVE SYSTEMS:
a. CHEMICAL ADHESIVE SYSTEMS SHALL BE USED TO INSTALL ALL DRILLED-IN ANCHOR COMPONENTS
(BOLTS, DOWELS, ETC,) INTO HARDENED CONCRETE.
b. NO CHEMICAL ADHESIVE SYSTEMS, ANCHORS, BOLTS, DOWELS, ETC. MAY BE INSTALLED EARLIER THAN
7 DAYS AFTER CONCRETE PLACEMENT.
c. SUBMIT CHEMICAL ADHESIVE PRODUCT CATALOG CUTS FOR APPROVAL.
8. ALL CONCRETE DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED BY THE CONTRACTOR IN AN APPROVED
MANNER AT THE CONTRACTOR'S EXPENSE.
9. REFER TO DIVISION 03 OF THE SPECIFICATIONS FOR ALL OTHER REQUIREMENTS.
GENERAL STRUCTURAL NOTES:
1. WORK ON STRUCTURAL DRAWINGS SHALL BE COORDINATED WITH OTHER DRAWINGS. ANY APPARENT
DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE STRUCTURAL ENGINEER FOR
CLARIFICATION PRIOR TO PROCEEDING ON SAID WORK.
2. NO CHANGES OF THE STRUCTURAL SYSTEM (INCLUDING SIZES AND SPACING OF MEMBERS) AS INDICATED ON THESE DRAWINGS SHALL BE PERFORMED PRIOR TO RECEIVING WRITTEN APPROVAL FROM THE
STRUCTURAL ENGINEER.
3. SECTIONS AND DETAILS ON THESE DRAWINGS ARE TO BE CONSIDERED TYPICAL FOR SIMILAR
CONSTRUCTION NOT FULLY DETAILED, UNLESS OTHERWISE INDICATED.
4. ALL WORK SHOWN ON THE DRAWINGS IS TO BE CONSIDERED NEW, UNLESS NOTED AS EXISTING.
CONTRACTOR SHALL PROVIDE ALL MATERIALS AND LABOR FOR COMPLETE INSTALLATION.
5. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND ELEVATIONS FOR THE PROPER CONSTRUCTION AND ALIGNMENT OF NEW WORK TO EXISTING WORK PRIOR TO STARTING CONSTRUCTION AND ORDERING
OF MATERIALS.
6. DO NOT SCALE DRAWINGS. CONTRACTOR SHALL NOTIFY ENGINEER OF ANY DISCREPANCIES IN DIMENSIONS
ON STRUCTURAL DRAWINGS AND WITH EXISTING CONDITIONS AND/OR OTHER DRAWINGS.
7. CONTRACTOR SHALL NOTIFY THE ENGINEER IN WRITING OF ALL PROPOSED DEVIATIONS OR SUBSTITUTIONS FROM DIMENSIONS, MATERIALS, OR EQUIPMENT SHOWN ON THE DRAWINGS AND MAKE ONLY THOSE DEVIATIONS OR SUBSTITUTIONS ACCEPTABLE TO THE ENGINEER. NO CHANGES SHALL BE MADE WITHOUT
APPROVAL BY THE ENGINEER.
8. CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARILY BRACING AND MAINTAINING THE STABILITY OF
ALL STRUCTURES DURING CONSTRUCTION. STRUCTURES SHALL BE ASSUMED UNSTABLE UNTIL
COMPONENTS (WALLS, ROOF, ETC.), AND ALL CONNECTIONS AND PERMANENT BRACING ARE INSTALLED.
9. ALL WORK SHALL BE IN ACCORDANCE WITH THE MANUFACTURER/FABRICATOR/DESIGNER'S WRITTEN
INSTRUCTIONS FOR PREPARATIONS AND INSTALLATION OF MATERIALS.
10. THESE DRAWINGS DO NOT IDENTIFY COMPONENTS REQUIRED FOR CONSTRUCTION SAFETY. CONTRACTOR IS SOLELY RESPONSIBLE FOR EXECUTING THE WORK AND MAINTAINING THE WORK SITE IN ACCORDANCE
WITH ALL APPLICABLE SAFETY CODES AND STANDARDS.
11. CONTRACTOR SHALL PROVIDE PROTECTIVE BARRICADES, SIGNS AND LIGHTING TO PREVENT ANY
UNAUTHORIZED ENTRY INTO WORK AREA.
12. CONTRACTOR SHALL BE RESPONSIBLE TO PROTECT THE EXISTING FACILITY AND ANCILLARIES. ANY DAMAGE CAUSED BY THE CONTRACTOR SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE OWNER.
13. CONTRACTOR SHALL DETERMINE EXACT LOCATION OF EXISTING UTILITIES BEFORE COMMENCING WORK AND SHALL BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT OCCUR BY FAILING TO
EXACTLY LOCATE AND PROTECT UNDERGROUND AND OTHER UTILITIES.
SPECIAL INSPECTIONS:
1. SPECIAL INSPECTIONS ARE REQUIRED FOR PORTIONS OF THIS WORK. REFER TO STATEMENT OF SPECIAL
INSPECTIONS FOR REQUIRED INSPECTIONS AND TESTING.
2. CONTRACTOR SHALL COORDINATE AND SCHEDULE WORK TO ALLOW FOR REQUIRED SPECIAL INSPECTIONS AND
STRUCTURAL TESTING TO BE CONDUCTED IN A TIMELY MANNER.
EARTHWORK AND FOUNDATIONS NOTES (REFERENCE DIVISION 31 SPEC'S)
1. FOUNDATION DESIGN AND SUBGRADE PREPARATIONS ARE DESIGNED AS RECOMMENDED IN GEOTECHNICAL
REPORT PREPARED BY ATLANTIC TESTING LABORATORIES, LIMITED DATED APRIL 9, 2024.
2. ALL FOUNDATIONS SHALL BE CONSTRUCTED ON FIRM UNDISTURBED SUBGRADE, BEDROCK, OR APPROVED
STRUCTURAL FILL.
3. REMOVE ALL UNSUITABLE MATERIAL INCLUDING WOOD FRAGMENTS, GLASS, BRICK, AND ORGANICS WITHIN FIVE FEET OF THE SPECIFIED FOUNDATIONS. REPLACE UNSUITABLE FILL MATERIALS ENCOUNTERED IN FOOTING
EXCAVATIONS WITH GRANULAR FILL PROPERLY PLACED AND COMPACTED.
4. STRUCTURAL FILL SHALL BE USED TO RAISE GRADES BELOW FOOTINGS AND CONCRETE SLABS-ON-GRADE AND
TO BE PLACED AS BACKFILL IMMEDIATELY AGAINST STRUCTURES.
5. CONTRACTOR SHALL ALLOW OWNER'S REPRESENTATIVE TO VERIFY ACCEPTABLE SUBGRADE CONDITIONS PRIOR TO PLACEMENT OF STRUCTURAL FILL AND/OR CONSTRUCTION OF FOUNDATIONS AND SLABS-ON-GRADE.
6. EXPOSED SUBGRADE IN OPEN EXCAVATIONS SHALL BE PROTECTED FROM RAIN AND/OR GROUNDWATER THAT COULD COMPROMISE THEIR CONDITION. CONTRACTOR SHALL PROVIDE COVER AND/OR CASTING OF 3-INCH CLSM MUDMAT AS NEEDED. FOOTING SUBGRADES THAT BECOME SATURATED AND UNSTABLE SHALL BE OVEREXCAVATED AND REPLACED WITH 6-INCH LAYER OF NYSDOT NUMBER 2 CRUSHED STONE COMPACTED
PER THE PROJECT DOCUMENTS AND ON-SITE GEOTECHNICAL TESTING AGENCY.
7. FOUNDATIONS SHALL NOT BE CAST ON FROZEN SUBGRADE OR FROZEN STRUCTURAL FILL MATERIAL. DO NOT
PLACE STRUCTURAL FILL ON FROZEN SUBGRADE.
8. ALL EXCAVATIONS SHALL BE DEWATERED AS NECESSARY TO MAINTAIN GROUNDWATER AT LEAST 24" BELOW
FOOTING BEFORE PLACING OF CONCRETE.
9. ALL EXCAVATIONS INTO UNDISTURBED SOILS SHALL BE PROOF ROLLED USING A VIBRATORY SMOOTH DRUM
ROLLER WEIGHING AT LEAST 10 TONS.
10. STRUCTURAL FILL SHALL BE AS SPECIFIED IN SECTION 31 05 16. ALL FILL MATERIALS SHALL BE PLACED WITHIN 2
PERCENT OF THE OPTIMUM MOISTURE AT THE TIME OF COMPACTION.
11. GEOTEXTILE FABRIC SHALL BE NEEDLE-PUNCHED, NONWOVEN GEOTEXTILE COMPOSED OF POLYESTER AND/OR
POLYPROPYLENE POLYMERS. PROVIDE TENCATE MIRAFI 180N OR APPROVED EQUAL.
12. ALL STRUCTURAL FILL SHALL BE PLACED IN MAXIMUM 6-INCH LIFTS (AND AS DIRECTED BY THE ON-SITE SOILS TESTING AGENCY), COMPACTED TO 95% OF THE MATERIAL'S MAXIMUM DRY DENSITY AS DETERMINED BY ASTM D1557. IN-PLACE DENSITY SHALL BE DETERMINED BY ASTM D 6938. SEE SPECIFICATIONS FOR
COMPACTION AND FIELD TESTS.
13. CONTROLLED LOW-STRENGTH MATERIAL (CLSM) SHALL BE USED AS FLOWABLE FILL BENEATH AND/OR ADJACENT TO STRUCTURES WHERE NEEDED. CLSM SHALL BE NYSDOT APPROVED, AND SHALL BE MIXED AND PLACED IN ACCORDANCE WITH ACI 229. COMPRESSIVE STRENGTH OF CLSM SHALL BE BETWEEN 100 - 300 PSI.
14. REFER TO THE PROJECT SUBSURFACE INVESTIGATION AND GEOTECHNICAL EVALUATION FOR ADDITIONAL
SPECIFIC RECOMMENDATIONS.
*HORIZONTAL BARS INCLUDE:
1. HORIZONTAL WALL REINFORCING BARS.
2. TOP REINFORCING BARS IN SLABS AND FOOTINGS
GREATER THAN 12" THICK.
WOOD FRAMING NOTES (REFERENCE DIVISION 06 SPECIFICATIONS)
1. WOOD FRAMING MATERIALS SHALL BE AS SPECIFIED:
CONVENTIONAL WOOD FRAMING (GIRTS, 2x6 PURLINS, ETC.):
- DOUGLAS FIR-LARCH (DF-L), No. 2.
- SPRUCE-PINE-FIR (SPF), No. 1/ No. 2.
ENGINEERED WOOD FRAMING:
- LVL BEAMS/JOISTS/PURLINS SHALL BE MICROLAM LVL 1.9E.
WOOD PLATE-CONNECTED TRUSSES AND COMPOSITE TRUSSES:
- ALL TRUSSES SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF
NEW YORK.
- DESIGN LOADS FOR TRUSSES SHALL BE BASED ON THE "STRUCTURAL DESIGN CRITERIA" LISTED
ON THIS DRAWING.
- ALL ROOF TRUSSES ARE TO BE ORIENTATED AND SPACED AS INDICATED ON DRAWINGS.
- CONFIGURATION OF TRUSS CHORDS (VERTICAL AND DIAGONAL) ARE SCHEMATICS ONLY,
ACTUAL CONFIGURATION SHALL BE DETERMINED BY TRUSS DESIGNER.
WOOD SHEATHING:
- ROOF SHEATHING SHALL BE EXPOSURE 1 APA STRUCTURAL I RATED 5/8" PLYWOOD.
- GABLE END/ WALL SHEATHING SHALL BE T1-11 EXTERIOR APA RATED 5/8" SIDING.
2. ALL WOOD IN DIRECT CONTACT WITH CONCRETE FOUNDATIONS OR WITHIN 8" OF SOIL SHALL BE
PRESERVATIVE-TREATED (PT) WITH THE APPROPRIATE AWPA SYSTEM.
3. FASTENING OF ROOF SHEATHING SHALL BE AS FOLLOWS:
- 8d NAILS @ 6" O.C. ALONG EDGES
- 8d NAILS @ 12" O.C. IN THE FIELD
4. FASTENING OF GABLE END/ WALL SHEATHING SHALL BE AS FOLLOWS:
- 8d NAILS @ 6" O.C. ALONG EDGES
- 8d NAILS @ 12" O.C. IN THE FIELD
5. WOOD CONNECTIONS:
- ALL CONVENTIONAL WOOD FRAMING CONNECTIONS SHALL BE MADE WITH GALVANIZED FASTENERS
AND METAL CONNECTORS. CONNECTORS NOT INDICATED ON DRAWINGS SHALL BE A RECOMMENDED
SELECTION FROM SIMPSON STRONG-TIE OR EQUAL.
- PROVIDE HURRICANE TIE DOWNS/CONNECTORS AT EACH TRUSS BEARING END.
- PROVIDE CUSTOM ANCHOR PLATES AS INDICATED ON DRAWINGS AT BEARING ENDS OF COMPOSITE
TRUSSES.
- INSTALL ALL CONNECTORS PER THE MANUFACTURER'S REQUIREMENTS.
6. SUBMIT PROPOSED ANCHORS FOR EACH CONDITION FOR APPROVAL. CONTRACTOR MAY SUBMIT ALTERNATE ANCHORS FOR APPROVAL THAT ARE DOCUMENTED TO HAVE EQUAL OR GREATER CAPACITIES THAN THOSE
SPECIFIED AND THAT SATISFY THE DESIGN INTENT.
7. SUBMIT TRUSS SHOP DRAWINGS (COMPLIANT WITH ARTICLE 2303.4 OF THE BUILDING CODE) TO STRUCTURAL
ENGINEER FOR REVIEW AND APPROVAL PRIOR TO FABRICATION AND ERECTION.
- DRAWINGS AND CALCULATIONS ARE TO BE STAMPED BY A NEW YORK STATE LICENSED ENGINEER.
- ERECTION AND BRACING DETAILS TO BE PROVIDED BY TRUSS MANUFACTURER, INCLUDING GABLE
END AND OVERBUILD REQUIREMENTS.
REVISIONS
Date
Scale
Sheet Number
Ch ec ke d by Dr aw n by De sig ne d by
In C ha rg e of
Pl ot te d: Project Number
AS SHOWN
NYS EXP.:
N
YS
C
ER
TI
FI
CA
TE
6, 8, 3, , 0
8/ 5/
0:
:4
AM
I:
P ro je c ts
T o w n o f G re e n vi lle .0 .0 S a lt
S to ra g e
B u ild in g .0 .0 S a lt
S to ra g e
B u ild in g .r vt
CM
K
/ J M
C G
C / J
M C
S001
SEPTEMBER 2026
TO
W
N O
F
GR
EE
N
VI
LL
E
TO
W
N O
F
GR
EE
N
VI
LL
EG
EN
ER
AL
S
TR
U
CT
U
RA
L N
O
TE
S
SA
LT
S
TO
RA
G
E
FA
CI
LI
TY
G
RE
EN
E
CO
U
N
TY
, N
EW
Y O
RK
CM
K
2323.003.001
C M
K
04/30/2027
REINFORCING BAR LAP SPLICE LENGTHS
BAR SIZE
HORIZONTAL
BAR OTHER BARS
#4 24" 18" #5 30" 24" #6 36" 30" #7 54" 42" #8 66" 48" #9 78" 60"
8'-0"8'-0"8'-0"8'-0"8'-0"8'-0"8'-0"8'-0"8'-0"8'-0"8'-0"
'-0
8'-0" 7'-8" 24'-8"
5' -0
3' -1
0"
7'-8" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0"
3'-0" 3'-0"
S302
S503
S503
S503
5'-0"
S302
8'-0"8'-0"
114'-0"
5' -0
'-0
S503
8' -0
8'
-0
8' -0
8'
-0
8' -0
8'
-0
8' -0
8'
-0
8' -0
8'
-0
S503
S301
8'-0" 1'-3"
106'-6"3'-9" 3'-9"
S503
S302
S503
S503
S503
S503
S503
1' -2
TY
P) 1'-2" (TYP)
1' -2
TY
P)
1'-2" (TYP)
8" (TYP)
5' -0
1' -2
1'-3" 8'-0"
FTG CONST JT
WALL CONST JT
FTG CONST JT
WALL CONST JT
FTG CONST JT
WALL CONST JT
FTG CONST JT
WALL CONST JT
FTG CONST JT
WALL CONST JT
FTG CONST JT
WALL CONST JT
FTG CONST JT
WALL CONST JT
FTG CONST JT
WALL CONST JT
FT
G
CO
N
ST
JT
W
AL
L
CO
NS
T
JT
FT
G
CO
N
ST
JT
W
AL
L
CO
NS
T
JT
FT
G
CO
N
ST
JT
W
AL
L
CO
NS
T
JT
FT
G
CO
N
ST
JT
W
AL
L
CO
NS
T
JT
FT
G
CO
N
ST
JT
W
AL
L
CO
NS
T
JT
5'-0" 5'-0"
5'-0"
5' -0
5'
-0
5' -0
5'
-0
REVISIONS
Date
Scale
Sheet Number
Ch ec ke d by Dr aw n by De sig ne d by
In C ha rg e of
Pl ot te d: Project Number
AS SHOWN
NYS EXP.:
N
YS
C
ER
TI
FI
CA
TE
6, 8, 3, , 0
8/ 5/
0:
:4
AM
I:
P ro je c ts
T o w n o f G re e n vi lle .0 .0 S a lt
S to ra g e
B u ild in g .0 .0 S a lt
S to ra g e
B u ild in g .r vt
CM
K
/ J M
C G
C / J
M C
S101
SEPTEMBER 2026
TO
W
N O
F
GR
EE
N
VI
LL
E
TO
W
N O
F
GR
EE
N
VI
LL
E
SA
LT
S
TO
RA
G
E
BU
IL
DI
N G
F O
U N
DA
TI
O N
P
LA
N
SA
LT
S
TO
RA
G
E
FA
CI
LI
TY
G
RE
EN
E
CO
U
N
TY
, N
EW
Y O
RK
CM
K
2323.003.001
C M
K
04/30/2027
0 6' 12'4' 3/16" = 1'-0"
TRUE
NORTH
N
PLAN
NORTH
N
SCALE: 3/16" = 1'-0"
FOUNDATION PLAN NOTE: 'ALTERNATE' STRUCTURE IS SIMILAR, BUT HAS A WOOD BARRIER
WALL INSTEAD OF 14" CONCRETE WALL. REFERENCE SECTION 13 37 00.
S302
S302
'-1
/4
24'-6" 24'-0" 56'-6"
2X
RO
O
F
PU
RL
IN
(F
LA
T)
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
COMPOSITE WOOD TRUSSES
@ 8'-0" O.C. (TYP.)
MULTI-PLY COMPOSITE WOOD TRUSSES
105'-0"
S301
8'-6" 8'-0" 8'-0" 24'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-6"
COMPOSITE WOOD TRUSSES
@ 8'-0" O.C. (TYP.)
S302
GA
BL
E
TR
U
SS
ES
'-0
" S
PA
CI
N
G
2X
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
(F
LA
T)
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
(F
LA
T)
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
(F
LA
T)
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
(F
LA
T)
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
(F
LA
T)
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
(F
LA
T)
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
(F
LA
T)
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
(F
LA
T)
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
(F
LA
T)
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
(F
LA
T)
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
(F
LA
T)
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
(F
LA
T)
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
(F
LA
T)
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
(F
LA
T)
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
(F
LA
T)
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
(F
LA
T)
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
(F
LA
T)
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
(F
LA
T)
'-0
" O .C
TY
P.
2X
RO
O
F
PU
RL
IN
(F
LA
T)
'-0
" O .C
TY
P.
1.
X1 1.
(L
VL
) R O
O F
PU
RL
IN
S
'-0 " O
.C
TY
P.
1.
X1
1.
(L
VL
RO
O
F
PU
RL
IN
S
'-0
" O .C
TY
P.
2X6 ROOF PURLIN (FLAT)
@ 2'-0" O.C. (TYP.)
2x6 CROSS BRACING FASTENED
TO UNDERSIDE OF ROOF PURLINS
(TYPICAL (24) LOCATIONS)
REVISIONS
Date
Scale
Sheet Number
Ch ec ke d by Dr aw n by De sig ne d by
In C ha rg e of
Pl ot te d: Project Number
AS SHOWN
NYS EXP.:
N
YS
C
ER
TI
FI
CA
TE
6, 8, 3, , 0
8/ 5/
0:
:4
AM
I:
P ro je c ts
T o w n o f G re e n vi lle .0 .0 S a lt
S to ra g e
B u ild in g .0 .0 S a lt
S to ra g e
B u ild in g .r vt
CM
K
/ J M
C G
C / J
M C
S102
SEPTEMBER 2026
TO
W
N O
F
GR
EE
N
VI
LL
E
TO
W
N O
F
GR
EE
N
VI
LL
E
SA
LT
S
TO
RA
G
E
BU
IL
DI
N G
F
RA
M
IN
G P
LA
N
SA
LT
S
TO
RA
G
E
FA
CI
LI
TY
G
RE
EN
E
CO
U
N
TY
, N
EW
Y O
RK
CM
K
2323.003.001
C M
K
04/30/2027
0 6' 12'4' 3/16" = 1'-0"
TRUE
NORTH
N
PLAN
NORTH
N
SCALE: 3/16" = 1'-0"
FRAMING PLAN
NOTE: 'ALTERNATE' STRUCTURE IS SIMILAR, BUT HAS A WOOD BARRIER
29 GA. METAL ROOFING
PANELS ON 30# TITANIUM
UNDERLAYMENT ON 5/8"
PLYWOOD ROOF DECK (TYP.)
5/8" T1-11 WALL PANELING (TYP.)
5/8" T1-11 WALL PANELING (TYP.)
14" CONCRETE
WALL (TYP.)
40'-0" 40'-0"
'-2
5'-0"
'-0
80'-0"
5"
1'-0"
5"
1'-0"
2'-5"
1'-0"
2'-5"
1'-0"
14" CONCRETE
WALL (TYP.)
(5)-PLY 2x8 POSTS (TYP.)
25'-3" 24'-0" 57'-3"
106'-6"
29 GA. METAL ROOFING PANELS
ON 30# TITANIUM
UNDERLAYMENT ON 5/8"
PLYWOOD ROOF DECK (TYP.)
105'-8"
5" 5"
'-0
'-2
6"
1'-0"
6"
1'-0"
5/8" T1-11 WALL PANELING
29 GA. METAL ROOFING PANELS
ON 30# TITANIUM
UNDERLAYMENT ON 5/8"
PLYWOOD ROOF DECK (TYP.)
14" CONCRETE
WALL (TYP.)
'-2
'-0
105'-8"
5" 5"
106'-6"
29 GA. METAL ROOFING
PANELS ON 30# TITANIUM
UNDERLAYMENT ON 5/8"
PLYWOOD ROOF DECK (TYP.)
5/8" T1-11 WALL PANELING (TYP.)
5/8" T1-11 WALL PANELING (TYP.)
14" CONCRETE
WALL (TYP.)
40'-0" 40'-0" 5'-0"
5/8" T1-11 WALL PANELING
80'-0"
'-2
'-0
5"
1'-0"
5"
1'-0"
2'-5"
1'-0"
2'-5"
1'-0"
REVISIONS
Date
Scale
Sheet Number
Ch ec ke d by Dr aw n by De sig ne d by
In C ha rg e of
Pl ot te d: Project Number
AS SHOWN
NYS EXP.:
N
YS
C
ER
TI
FI
CA
TE
6, 8, 3, , 0
8/ 5/
0:
:4
AM
I:
P ro je c ts
T o w n o f G re e n vi lle .0 .0 S a lt
S to ra g e
B u ild in g .0 .0 S a lt
S to ra g e
B u ild in g .r vt
CM
K
/ J M
C G
C / J
M C
S201
SEPTEMBER 2026
TO
W
N O
F
GR
EE
N
VI
LL
E
TO
W
N O
F
GR
EE
N
VI
LL
E
SA
LT
S
TO
RA
G
E
BU
IL
DI
N G
E
LE
VA
TI
O N
S
SA
LT
S
TO
RA
G
E
FA
CI
LI
TY
G
RE
EN
E
CO
U
N
TY
, N
EW
Y O
RK
CM
K
2323.003.001
C M
K
04/30/2027
0 8' 16'8' 1/8" = 1'-0"
SCALE: 1/8" = 1'-0"
EAST ELEVATION
SCALE: 1/8" = 1'-0"
SOUTH ELEVATION
SCALE: 1/8" = 1'-0"
NORTH ELEVATION
SCALE: 1/8" = 1'-0"
WEST ELEVATION
NOTE: 'ALTERNATE' STRUCTURE IS SIMILAR, BUT HAS A WOOD BARRIER
WALL INSTEAD OF 14" CONCRETE WALL. REFERENCE SECTION 13 37 00.
NOTE: WALL PANELING AND ALL EXTERIOR EXPOSED WOOD TRIM AND
POSTS SHALL BE PAINTED IN ACCORDANCE WITH SECTION 09 91 00.
NOTE: WALL PANELING AND ALL EXTERIOR EXPOSED WOOD TRIM
SHALL BE PAINTED IN ACCORDANCE WITH SECTION 09 91 00.
NOTE: WALL PANELING AND ALL EXTERIOR EXPOSED WOOD TRIM
SHALL BE PAINTED IN ACCORDANCE WITH SECTION 09 91 00.
NOTE: WALL PANELING AND ALL EXTERIOR EXPOSED WOOD TRIM
SHALL BE PAINTED IN ACCORDANCE WITH SECTION 09 91 00.
T/FTG
933' - 0"
GRADE
935' - 6"
CEILING
975' - 6"
ENTRANCE
HEIGHT
967' - 3"
T/ WALL
947' - 6"
S501
S502
8' -3
'-9
S502
'-0
S502
'-2
6"
FINISH SUBGRADE
5"
1'-0"
2'-5"
1'-0"
5"
1'-0"
2'-5"
1'-0"
29 GA. METAL ROOFING PANELS ON
30# SELF-ADHERED RUBBERIZED
ASPHALT UNDEUNDERLAYMENT ON
5/8" PLYWOOD ROOF DECK (TYP.)
29 GA. METAL ROOFING PANELS ON
30# SELF-ADHERED RUBBERIZED
ASPHALT UNDEUNDERLAYMENT ON
5/8" PLYWOOD ROOF DECK (TYP.)
COMPOSITE TRUSS
2' -6
S501
REVISIONS
Date
Scale
Sheet Number
Ch ec ke d by Dr aw n by De sig ne d by
In C ha rg e of
Pl ot te d: Project Number
AS SHOWN
NYS EXP.:
N
YS
C
ER
TI
FI
CA
TE
6, 8, 3, , 0
8/ 5/
0:
:4
AM
I:
P ro je c ts
T o w n o f G re e n vi lle .0 .0 S a lt
S to ra g e
B u ild in g .0 .0 S a lt
S to ra g e
B u ild in g .r vt
G C
/ J M
C G
C / J
M C
S301
SEPTEMBER 2026
TO
W
N O
F
GR
EE
N
VI
LL
E
TO
W
N O
F
GR
EE
N
VI
LL
E
SA
LT
S
TO
RA
G
E
BU
IL
DI
N G
S
EC
TI
O
N
SA
LT
S
TO
RA
G
E
FA
CI
LI
TY
G
RE
EN
E
CO
U
N
TY
, N
EW
Y O
RK
2323.003.001
04/30/2027
SCALE: 1/4" = 1'-0"S101
OVERALL BUILDING SECTION1
NOTE: 'ALTERNATE' STRUCTURE IS SIMILAR, BUT HAS A WOOD BARRIER
WALL INSTEAD OF 14" CONCRETE WALL. REFERENCE SECTION 13 37 00.
C M
K
CM
K
GRADE
935' - 6"
CEILING
975' - 6"
ENTRANCE
HEIGHT
967' - 3"
T/ WALL
947' - 6"
'-2
'-6
1'
-8
1.75X11.875 (LVL)
ROOF PURLINS @
2'-0" O.C. (TYP.)
COMPOSITE WOOD TRUSS @ 8'-0" O.C. (TYP.)
SEE NOTE 1 FOR WOOD TRUSSES @ DOORWAY OPENING
2X6 ROOF PURLINS (FLAT)
@ 2'-0" O.C. (TYP.)
'-6
'-8
VERTICAL BUTTRESS AT
DOORWAY OPENING (TYP.)
'-2
(2) 2x12 HEADER BEAM
(TYP.)
40'-0"
29 GA. METAL ROOFING PANELS ON 30# SELF-ADHERED
RUBBERIZED ASPHALT UNDERLAYMENT ON 5/8" CDX
PLYWOOD ROOF DECK (TYP.)
5'-0"
5-PLY 2x8 POST (TYP.)
FINISH SUBGRADE
6"
2X6 WALL GIRTS
@ 2'-0" O.C. (TYP.)
2X6 ROOF PURLINS (FLAT)
@ 2'-0" O.C. (TYP.)
S501
1 (SIMILAR)
2x6 BRACE (TYP.)
S502
S502
WOOD BLOCKING @ 4' O.C.
BETWEEN ALL LVL SIDE PURLINS
T/FTG
933' - 0"
GRADE
935' - 6"
CEILING
975' - 6"
T/ WALL
947' - 6"
5-PLY 2x8 ENDWALL POSTS
@ 8'-0" O.C. (TYP.)
(SEE DETAIL 8/S502)
2X6 ENDWALL GIRTS
@ 2'-0" O.C. (TYP.)
COMPOSITE WOOD TRUSS
@ 8'-0" O.C. (TYP.)
2X6 ROOF PURLIN
@ 2'-0" O.C. (TYP.)
FINISH SUBGRADE
29 GA. METAL ROOFING PANELS ON
30# SELF-ADHERED RUBBERIZED
ASPHALT UNDEUNDERLAYMENT ON
5/8" PLYWOOD ROOF DECK (TYP.)
'-2
'-6
1'
-8
'-2
(2) 2X8 KNEE BRACES AT
ENDWALL COLUMNS
5/8" T1-11 WALL
PANELING (TYP.)
S502
S502
S502
45°
6"
S502
S501
REVISIONS
Date
Scale
Sheet Number
Ch ec ke d by Dr aw n by De sig ne d by
In C ha rg e of
Pl ot te d: Project Number
AS SHOWN
NYS EXP.:
N
YS
C
ER
TI
FI
CA
TE
6, 8, 3, , 0
8/ 5/
0:
:5
AM
I:
P ro je c ts
T o w n o f G re e n vi lle .0 .0 S a lt
S to ra g e
B u ild in g .0 .0 S a lt
S to ra g e
B u ild in g .r vt
CM
K
/ J M
C G
C / J
M C
S302
SEPTEMBER 2026
TO
W
N O
F
GR
EE
N
VI
LL
E
TO
W
N O
F
GR
EE
N
VI
LL
E
SA
LT
S
TO
RA
G
E
BU
IL
DI
N G
S
EC
TI
O
N S
SA
LT
S
TO
RA
G
E
FA
CI
LI
TY
G
RE
EN
E
CO
U
N
TY
, N
EW
Y O
RK
CM
K
2323.003.001
C M
K
04/30/2027
SCALE: 1/4" = 1'-0"S101
SECTION THRU SIDEWALL AT DOORWAY2
0 4' 8'4' 1/4" = 1'-0"
NOTES:
1. PLACE MINIMUM 6 INCHES OF STRUCTURAL FILL IF GROUNDWATER IS NOT
ENCOUNTERED. IF GROUNDWATER IS ENCOUNTERED, PLACE MINIMUM 6
INCHES OF #2 STONE.
NOTES:
1. PLACE MINIMUM 6 INCHES OF STRUCTURAL FILL IF GROUNDWATER IS NOT
ENCOUNTERED. IF GROUNDWATER IS ENCOUNTERED, PLACE MINIMUM 6
INCHES OF #2 STONE.
SCALE: 1/4" = 1'-0"S101
SECTION THRU ENDWALL3
NOTE: 'ALTERNATE' STRUCTURE IS SIMILAR, BUT HAS A WOOD BARRIER
BUTTRESS
(SEE SECTION 2)
#6@10" DWL E.F.
1' -8
1'-2"
3'-10"
#6@10" V E.F.
#6@10" H E.F.
#6@10" T&B E.W.
GRADE
935' - 6"
T/ WALL
947' - 6"
S501
'-6
SEE NOTE 1
FINISH
GRADE
FINISH SUBGRADE
5'-0"
10'-0"
T/FTG
933' - 0"
GRADE
935' - 6"
T/ WALL
947' - 6"
#6@10" H&V
'-6
8"
1' -8
SEE NOTE 1
BACKER ROD
AND SEALANT
1"
CH
AM
FE
R
3/ 4"
1/2"
CONTROL JOINTS
CH
AM
FE
R
3/ 4"
CONSTRUCTION JOINTS
FACE OF
CONCRETE
U-BARS AT END OF WALLS AND OPENINGS
SHALL MATCH SIZE AND SPACING OF
HORIZONTALS REINFORCING BARS
WALL CORNERS WALL INTERSECTION
DISCONTINUOUS ENDS
T
LAP SPLICE
CLR
2"
LAP SPLICE
LA
P
SP
LI
CE
STANDARD 90° HOOKED BAR
TO MATCH SIZE AND
SPACING OF HORIZONTAL
REINFORCING BARS, U.N.O.
LA
P
SP
LI
CE
CORNER BARS TO MATCH SIZE
AND SPACING OF HORIZONTAL
REINFORCING BARS, U.N.O.
STANDARD 90° HOOKED BAR
TO MATCH SIZE AND
SPACING OF HORIZONTAL
REINFORCING BARS, U.N.O.
0" (TYP) 0" (TYP)
WALL CONSTRUCTION JOINT (CS JT)
(PLAN VIEW)
STANDARD 90°
HOOK (TYP)
WALL INTERSECTION CONSTRUCTION JOINT
0"
TY
P)
LA
P
SP
LI
CE
LAP SPLICE LAP SPLICE
TERMINATE BAR 2" FROM JOINT
KEYWAY KEYWAY
WALL CONTROL JOINT (CL JT)
(PLAN VIEW)
EXTEND 50% OF BARS THROUGH JOINT
(ALTERNATE BARS EACH FACE)
TERMINATE BAR 2" FROM JOINT
EXTEND ALL BARS THROUGH JOINT
1/
2" P
O
CK
ET
TERMINATE BARS
2" FROM JOINT
OPTIONAL WALL CONTROL JOINT (CL JT)
(PLAN VIEW)
EXTEND 50% OF BARS
THROUGH JOINT
(ALTERNATE BARS EACH FACE)
NOTE: THIS OPTIONAL CONTROL JOINT IS ONLY APPLICABLE
FOR WALLS 12" THICK OR LESS.
0" (T
YP
0" (T
YP
0" (TYP)
SEE FORMED
JOINT DETAILS
SEE FORMED JOINT DETAILS
SEE FORMED
JOINT DETAILS
NOTES:
1. EXTENTS AND PROJECTION (SLOPE) OF STRUCTURAL FILL SHOWN ARE OF MINIMUM REQUIREMENTS.
2. STRUCTURAL FILL SHALL BE MATERIAL AS SPECIFIED ON THE DRAWINGS AND SPECIFICATIONS.
FIRM SUBGRADE
(MIN)
6"
COMPACTED STRUCTURAL FILL
OPTIONAL PLACEMENT
OF STRUCTURAL FILL
CONCRETE FOUNDATION
U .N
.O
6"
2X4
KEYWAY
TOP OF FOOTING
SEE DETAILS/SECTIONS FOR REINFORCEMENT
NOTES:
1. LOCATE CONSTRUCTION JOINT AT A CONTROL JOINT (CJ) LOCATION AND STOP EVERY OTHER TOP AND BOTTOM
LONGITUDINAL BAR 2" CLR. FROM FACE OF JOINT.
2. LOCATIONS TO BE DETERMINED IN FIELD AT APPROXIMATELY 30' - 0" O.C. (MAX) SPACING.
3. PREPARE JOINT FACE PRIOR TO CONTINUING CONCRETE PLACEMENT IN ACCORDANCE WITH THE SPECIFICATIONS.
4. CONTRACTOR SHALL WAIT 48 HOURS BETWEEN PLACEMENT OF ADJACENT SECTIONS OF CONCRETE.
FIRST
PLACEMENT
SECOND
PLACEMENT
SE
E
PL
AN
(TYP.)
CLASS B LAP SPLICE2"
3"
REVISIONS
Date
Scale
Sheet Number
Ch ec ke d by Dr aw n by De sig ne d by
In C ha rg e of
Pl ot te d: Project Number
AS SHOWN
NYS EXP.:
N
YS
C
ER
TI
FI
CA
TE
6, 8, 3, , 0
8/ 5/
0:
:5
AM
I:
P ro je c ts
T o w n o f G re e n vi lle .0 .0 S a lt
S to ra g e
B u ild in g .0 .0 S a lt
S to ra g e
B u ild in g .r vt
CM
K
/ J M
C G
C / J
M C
S501
SEPTEMBER 2026
TO
W
N O
F
GR
EE
N
VI
LL
E
TO
W
N O
F
GR
EE
N
VI
LL
E
FO
U
N
DA
TI
O
N D
ET
AI
LS
SA
LT
S
TO
RA
G
E
FA
CI
LI
TY
G
RE
EN
E
CO
U
N
TY
, N
EW
Y O
RK
CM
K
2323.003.001
C M
K
04/30/2027
SCALE: 1/2" = 1'-0"
FOUNDATION WALL SECTION1
SCALE: 1/2" = 1'-0"
BUTTRESS WALL SECTION2
0 2' 4'2' 1/2" = 1'-0"
NOTES:
1. PLACE MINIMUM 6 INCHES OF STRUCTURAL FILL IF GROUNDWATER IS NOT
ENCOUNTERED. IF GROUNDWATER IS ENCOUNTERED, PLACE MINIMUM 6
INCHES OF #2 STONE.
NOTES:
1. PLACE MINIMUM 6 INCHES OF STRUCTURAL FILL IF GROUNDWATER IS NOT
ENCOUNTERED. IF GROUNDWATER IS ENCOUNTERED, PLACE MINIMUM 6
INCHES OF #2 STONE.
NOT TO SCALE
CONCRETE FORMED JOINT DETAILS3
NOT TO SCALE
CONCRETE WALL REINF BAR DETAILS (2 LAYERS)4
NOT TO SCALE
CONCRETE WALL JOINT DETAILS (2 LAYERS)5
NOT TO SCALE
TYPICAL STRUCTURAL FILL PLACEMENT7
NOT TO SCALE
TYPICAL FOOTING CONSTRUCTION JOINT6
NOTE: 'ALTERNATE' STRUCTURE HAS A WOOD BARRIER WALL
INSTEAD OF 14" CONCRETE WALL. REFERENCE SECTION 13 37 00.
CEILING
975' - 6"
2" (MIN) OVERHANG
COMPOSITE TRUSS FASTENED
TOGETHER PER TRUSS MANUFACTURER
29 GA. METAL ROOFING PANELS ON
30# SELF-ADHERED RUBBERIZED
ASPHALT UNDEUNDERLAYMENT ON
5/8" PLYWOOD ROOF DECK (TYP.)
T/ WALL
947' - 6"
3/
4" (M
IN
) O
VE
RH
AN
G
BASE MOUNT BRACKET
(SEE DETAILS ON S503)
29 GA. METAL ROOFING PANELS ON
30# SELF-ADHERED RUBBERIZED
ASPHALT UNDEUNDERLAYMENT ON
5/8" PLYWOOD ROOF DECK (TYP.)
(2) 2x8 BRACES
(ONE EACH SIDE OF POSTS)
(2) 1/2" ⌀ GALV THRU-BOLTS
TYPICAL ENDWALL POST
(2) 2x8 BRACES
(ONE EACH SIDE OF POSTS)
(2) GALV CLIP CONNECTORS
TYPICAL COMPOSITE TRUSS
INFILL BLOCKING BETWEEN BRACES
BOTTOM CHORD OF COMPOSITE TRUSS
(2) 2x8 BRACES
(ONE EACH SIDE OF POSTS)
(2) GALV CLIP CONNECTORS
TYPICAL COMPOSITE TRUSS
BLOCKING BETWEEN BRACES
TOP CHORD OF COMPOSITE TRUSS
1/2" ⌀ GALV BOLTS (TYP)
(5) PLIES OF 2x8
4" 8"
O .C
TY
P)
2" 2"
BUTYL TAPE
VENTED Z CLOSURE & NEOPRENE CLOSURE
2X6 PURLINS @ 2'-0" O.C. METAL ROOF PANEL SYSTEM
MIN.
2"
COMPOSITE ROOF TRUSSES
VENTED RIDGE CAP, AS RECOMMENDED
BY METAL ROOF PANEL MFGR.
4"
COMPOSITE TRUSS
2x6 FASCIA
METAL RAKE EDGE
REVISIONS
Date
Scale
Sheet Number
Ch ec ke d by Dr aw n by De sig ne d by
In C ha rg e of
Pl ot te d: Project Number
AS SHOWN
NYS EXP.:
N
YS
C
ER
TI
FI
CA
TE
6, 8, 3, , 0
8/ 5/
0:
:5
AM
I:
P ro je c ts
T o w n o f G re e n vi lle .0 .0 S a lt
S to ra g e
B u ild in g .0 .0 S a lt
S to ra g e
B u ild in g .r vt
CM
K
/ J M
C G
C / J
M C
S502
SEPTEMBER 2026
TO
W
N O
F
GR
EE
N
VI
LL
E
TO
W
N O
F
GR
EE
N
VI
LL
E
TY
PI
CA
L
FR
AM
IN
G
D
ET
AI
LS
SA
LT
S
TO
RA
G
E
FA
CI
LI
TY
G
RE
EN
E
CO
U
N
TY
, N
EW
Y O
RK
CM
K
2323.003.001
C M
K
04/30/2027
SCALE: 1" = 1'-0"
ROOF TRANSITION DETAIL1
SCALE: 1" = 1'-0"
COMPOSITE TRUSS ANCHOR POINT2
SCALE: 1" = 1'-0"
BRACING TO POST DETAIL5
SCALE: 1" = 1'-0"
BRACING TO BOTTOM CHORD DETAIL4
SCALE: 1" = 1'-0"
BRACING TO TOP CHORD DETAIL3
SCALE: 1 1/2" = 1'-0"
MULTI-PLY POST DETAIL8
SCALE: 3" = 1'-0"
ROOF RIDGE DETAIL6
3" 1'0 3" = 1'-0"
6" 9"
6" 1'1' 1 1/2" = 1'-0"
0 1' 2'1' 1" = 1'-0"
SCALE: 1 1/2" = 1'-0"
ROOF RAKE DETAIL7
NOTE: THESE DETAILS ARE FOR 'BASE BID' STRUCTURE. 'ALTERNATE'
STRUCTURE COULD BE SIMILAR. REFERENCE SECTION 13 37 00.
2 1/2" EQ 2 1/2"EQ
NOTE 2
SEE
1'-6" 1'-1"
TRUSS 18"X10"X3/8" PLATE
13"X10"X3/8" PLATE
SLOTTED HOLE 9/16"X3"
(TOP PLATE AND PAD)
1/
2"
1/ 2"
T/ WALL
947' - 6"
1'-1"
NOTE 1
SEE EQEQ
1/2" ⌀ BOLTS AND NUTS
1/2" ⌀ BOLT AND NUT WITH
TEFLON WASHER. HEAD OF BOLT
TACK WELDED TO PLATE
3/4" ⌀ HEADED ANCHOR
10"X13"X3/8" PLATE
10"X13"X1/4" TEFLON PLATE
10"X18"X3/8" PLATE
1-1/2" (MIN) GROUT PAD
BELOW BOTTOM PLATE
(4) #3 TIES
(4) #3 U-BARS W/ 18" LEGS
1"
M
IN
T/ WALL
947' - 6"
1" 1" 2" 1" 1"
(2) 5"X6"X3/8" PLATES
WELDED TO TOP PLATE
1"
1-1/2" (MIN) GROUT PAD
BELOW BOTTOM PLATE
6"
3 1/2"
(4) #3 TIES
(4) #3 U-BARS W/ 18" LEGS
2"
1/ 2"
1'-10 1/2" 1'-5 1/2"
EQ SEE NOTE 2 EQ
1/
2"
T/ WALL
947' - 6"
(2) 5"X6"X3/8" PLATES
WELDED TO TOP PLATE
1-1/2" (MIN) GROUT PAD
BELOW BOTTOM PLATE
1" 1" 2" 1" 1"
6"
1"
3 1/2"
(4) #3 TIES
(6) #3 U-BARS W/ 18" LEGS
2"
1/ 2"
T/ WALL
947' - 6"
1/2" ⌀ BOLTS AND NUTS
1/2" ⌀ BOLT AND NUT WITH TEFLON
WASHER. HEAD OF BOLT TACK
WELDED TO PLATE
3/4" ⌀ HEADED ANCHOR
1-1/2" (MIN) GROUT PAD
BELOW BOTTOM PLATE
10"X17-1/2"X3/8" PLATE
10"X17-1/2"X1/4" TEFLON PAD
10"X22-1/2"X3/8" PLATE
TOP OF FOUNDATION WALL
1'-5 1/2"
EQ
NOTE 1
SEE EQ
1"
(4) #3 TIES
(6) #3 U-BARS W/ 18" LEGS
M
IN
TRUSS
15-1/2"X10"X3/8
" S.S. PLATE
17-1/2"X10"X3/8" S.S.
PLATE
SLOTTED HOLE 9/16"X3"
(TOP PLATE AND PAD)
1'-5 1/2"
1'-3 1/2"
5" 5"
4"10 7/8"5/8"
T/ WALL
947' - 6"5"
7"
1/2" ⌀ BOLTS AND NUTS
1/2" ⌀ BOLT AND NUT WITH
TEFLON WASHER. HEAD OF BOLT
TACK WELDED TO PLATE
3/4" ⌀ HEADED ANCHOR
20-1/2"X10"X3/8" BENT PLATE
15-1/2"X10"X1/4" TEFLON PAD
22-1/2"X10"X3/8" BENT PLATE 1-1/2" (MIN) GROUT PAD
BELOW BOTTOM PLATE
3"
2"
M
IN
(4) #3 TIES
(4) #3 U-BARS W/ 18" LEGS
T/ WALL
947' - 6"
1" 1" 2" 1" 1"
6"
(2) 5"X6"X3/8" PLATES
WELDED TO TOP PLATE
1-1/2" (MIN) GROUT
PAD BELOW BOTTOM
PLATE
1"
1"
3 1/2"
(4) #3 TIES
(4) #3 U-BARS W/ 18" LEGS
2"
1/ 2"
4" 4" 8"
1/
2"
5/ 8"
8"
1' -5
/8
1/
8" 7/
8"3
/8
1/
2"
T/ WALL
947' - 6"
1/2" ⌀ BOLTS AND NUTS
1/2" ⌀ HEADED ANCHOR,
(MIN 12" EMBEDEMENT)
16"X6"X3/8"
PLATE
1-1/2" (MIN) GROUT PAD
BELOW BOTTOM PLATE
(4) #3 TIES
HOOPED AROUND
VERT BARS IN WALL
T/ WALL
947' - 6"
1" 1" 2" 1" 1"
6"
(2) 5"X6"X3/8" PLATES
WELDED TO TOP PLATE
1-1/2" (MIN) GROUT
PAD BELOW BOTTOM
PLATE
1" 8"
(4) #3 TIES HOOPED AROUND
VERT BARS IN WALL
2"
1/
2"T/ WALL
947' - 6"
1/2" ⌀ BOLTS AND NUTS
1/2" ⌀ HEADED ANCHOR
(MINIMUM 12" EMBEDEMENT)16"X8-1/2"X3/8" PLATE
1-1/2" (MIN) GROUT PAD
BELOW BOTTOM PLATE
(4) #3 TIES HOOPED AROUND
VERT BARS IN WALL
2"
1/ 2"
T/ WALL
947' - 6"
1"
1" 1" 2" 1"
6"
1"
(2) 5"X6"X3/8" PLATES
WELDED TO TOP PLATE
1-1/2" (MIN) GROUT
PAD BELOW BOTTOM
PLATE
(4) #3 TIES
HOOPED AROUND
VERT BARS IN WALL
NOTE 1
SEE
1/
4"
1/ 4"
1/
2"
1'-4"
EQ2" EQ 2"
1"
REVISIONS
Date
Scale
Sheet Number
Ch ec ke d by Dr aw n by De sig ne d by
In C ha rg e of
Pl ot te d: Project Number
AS SHOWN
NYS EXP.:
N
YS
C
ER
TI
FI
CA
TE
6, 8, 3, , 0
8/ 5/
0:
:5
AM
I:
P ro je c ts
T o w n o f G re e n vi lle .0 .0 S…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .