2026-03-25_CTSI - Broadband Remodel_Bulletin 1.pdf

PDF 5 MB Posted

Attached to
Confederated Tribes of Siletz Indians Broadband Remodel Project
Solicitation number
S-X21600-00016771
Issued by
Oregon

About this file

This document is a comprehensive set of architectural and engineering construction drawings (Bulletin 1, dated March 24, 2026) for the Broadband Remodel Project being undertaken by the Confederated Tribes of the Siletz Indians at their facility located at 107 SE Swan Avenue, Siletz, Oregon 97380. The project, identified as JMFMRC Project #250910, involves comprehensive renovation of Level 1 spaces including demolition of existing partitions, casework, and mechanical/plumbing systems; installation of new walls to create an IT room with server racks and a new pantry; installation of new HVAC mini-split heat pump systems with dehumidification; addition of plumbing for a new kitchen sink; and electrical infrastructure upgrades including lighting, power distribution, and control systems. The design is being managed by Jackola Engineering & Architecture, P.C., with project management by Julian Bushman-Copp, RA, and engineering by Andrew Hanson (Structural), Blake Bartusiak (Mechanical), and Chase Hallstrom (Electrical). The drawings include detailed architectural floor plans, reflected ceiling plans, floor finish schedules, mechanical HVAC plans with equipment specifications, plumbing supply and waste/vent plans, and full electrical lighting and power plans with fixture and equipment schedules.

The project scope encompasses interior renovation with significant infrastructure modifications including two Samsung 12,000 BTU mini-split heat pump systems (models AR12DXFAMWKXCV and AR12DXFAMWKNCV), FEHOM 150 pint dehumidifiers with condensate management, new gypsum wall board ceiling systems with seismic bracing requirements, vinyl plank flooring, acoustic ceiling tiles, and comprehensive electrical wiring for lighting and power circuits. All work must comply with 2025 Oregon Mechanical Specialty Code, 2023 Oregon Plumbing Specialty Code, 2025 Oregon Energy Efficiency Specialty Code, and applicable fire-rated assembly requirements. The mechanical contractor is responsible for field verification of existing conditions, coordination with owner for service interruptions, testing and balancing of HVAC systems, and replacement of all filters following construction. Specific requirements include minimum concrete compressive strength of 4,000 PSI for any new concrete curbing, insulation of all water lines, seismic bracing for suspended ceilings exceeding 1,000 square feet, and proper coordination between all trades to avoid conflicts with structural members, existing utilities, and fire suppression systems.

View the file

Other files

File Type Posted
RFP_SiletzBroadbandRemodel_2026.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DATE:

JACKOLA ENGR. & ARCH., P.C.

WITHOUT THE WRITTEN CONSENT OF

MAY NOT BE USED OR REPRODUCED

IS PROPRIETARY. THIS DOCUMENT

THE INFORMATION CONTAINED HEREIN

REVISIONS:

FOR CONSTRUCTION

KALISPELL

406-755-3208

BOZEMAN

406-586-0707

VANCOUVER

360-852-8746

DRAWN: CHECKED:

info@jackola.com jackola.com

G-001

03/17/2026

B R

O A

D B

A N

D R

E M

O D

E L

C O

N F

E D

E R

A T

E D

T R

IB

E

S O

F T

H E

S

IL

E T

Z I N

D

IA

N S

S E

S W

A N

A V

E

S

IL

E T

Z

O R

TITLE SHEET

JMFMRC

P R

O J E

C T

:2

BROADBAND REMODEL

CONFEDERATED TRIBES OF THE SILETZ INDIANS

107 SE SWAN AVE

SILETZ, OR 97380

SITE LOCATION MAPSITE VICINITY MAP

IMAGE SOURCE: HTTPS://EARTH.GOOGLE.COM/ IMAGE SOURCE: HTTPS://EARTH.GOOGLE.COM/

S

ITE

S

ITE

PROJECT INFORMATION:

OWNER / DEVELOPER

CONFEDERATED TRIBES OF SILETZ INDIANS

107 SE SWAN AVE

SILETZ, OR 97380

ATTN: SYD SOMES

EMAIL : SYDNEYS@CTSI.NSN.US

TEL: 541-351-0141

DESIGN PROFESSIONALS

JACKOLA ENGINEERING & ARCHITECTURE, P.C.

702 JEFFERSON STREET

VANCOUVER, WA 98660

PROJECT MANAGER: JULIAN BUSHMAN-COPP, RA

ARCHITECT: JULIAN BUSHMAN-COPP, RA

STRUCTURAL ENGINEER: ANDREW HANSON, PE

MECHANICAL ENGINEER: BLAKE BARTUSIAK, PE

ELECTRICAL DESIGNER: CHASE HALLSTROM

DATE:

JACKOLA ENGR. & ARCH., P.C.

WITHOUT THE WRITTEN CONSENT OF

MAY NOT BE USED OR REPRODUCED

IS PROPRIETARY. THIS DOCUMENT

THE INFORMATION CONTAINED HEREIN

REVISIONS:

FOR CONSTRUCTION

KALISPELL

406-755-3208

BOZEMAN

406-586-0707

VANCOUVER

360-852-8746

DRAWN: CHECKED:

info@jackola.com jackola.com

G-002

03/17/2026

B R

O A

D B

A N

D R

E M

O D

E L

C O

N F

E D

E R

A T

E D

T R

IB

E

S O

F T

H E

S

IL

E T

Z I N

D

IA

N S

S E

S W

A N

A V

E

S

IL

E T

Z

O R

GENERAL

INFORMATION

JMFMRC

P R

O J E

C T

:2

INDEX OF DRAWINGS

SHEET NUMBER SHEET NAME ISSUE DATE CURRENT REVISION REVISION DATE

TITLE

G-001 TITLE SHEET 03/17/2026

G-002 GENERAL INFORMATION 03/17/2026

ARCHITECTURAL

A-001 ARCHITECTURAL TITLE SHEET 03/17/2026

AD111 LEVEL 1 DEMOLITION PLAN 03/17/2026

AD121 LEVEL 1 DEMOLITION REFLECTED CEILING PLAN 03/17/2026

A-111 LEVEL 1 FLOOR PLAN 03/17/2026 1 03/24/26

A-121 LEVEL 1 REFLECTED CEILING PLAN 03/17/2026

A-131 LEVEL 1 FLOOR FINISH PLAN 03/17/2026

A-511 SECTION DETAILS 03/17/2026

A-601 DOOR SCHEDULES 03/17/2026

MECHANICAL

M-001 MECHANICAL TITLE SHEET 03/17/2026 1 03/24/26

M-111 LEVEL 1 HVAC PLAN 03/17/2026

M-141 ROOF HVAC PLAN 03/17/2026

M-601 MECHANICAL SCHEDULES & DETAILS 03/17/2026

PLUMBING

P-001 PLUMBING TITLE SHEET 03/17/2026 1 03/24/26

PD-111 LEVEL 1 PLUMBING DEMOLITION PLAN 03/17/2026

P-111 LEVEL 1 DOMESTIC SUPPLY PLAN 03/17/2026

P-121 LEVEL 1 WASTE & VENT PLAN 03/17/2026

P-601 PLUMBING SCHEDULES & DETAILS 03/17/2026

ELECTRICAL

E-001 ELECTRICAL TITLE SHEET 03/17/2026

ED111 LEVEL 1 ELECTRICAL DEMOLITION PLAN 03/17/2026

E-111 LIGHTING PLAN 03/17/2026

E-121 POWER PLAN 03/17/2026 1 03/24/26

E-601 ELECTRICAL SCHEDULES 03/17/2026 1 03/24/26

* NOTE *

THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET

MAY OR MAY NOT BE USED IN THIS SET OF DRAWINGS.

A-102

LEVEL 1 DISCIPLINE DESIGNATOR

LEVEL 2 DISCIPLINE DESIGNATOR

LEVEL SEQUENCE NUMBER

PLAN TYPE SEQUENCE NUMBER

SHEET TYPE DESIGNATOR

DATE:

JACKOLA ENGR. & ARCH., P.C.

WITHOUT THE WRITTEN CONSENT OF

MAY NOT BE USED OR REPRODUCED

IS PROPRIETARY. THIS DOCUMENT

THE INFORMATION CONTAINED HEREIN

REVISIONS:

FOR CONSTRUCTION

KALISPELL

406-755-3208

BOZEMAN

406-586-0707

VANCOUVER

360-852-8746

DRAWN: CHECKED:

info@jackola.com jackola.com

A-001

03/17/2026

B R

O A

D B

A N

D R

E M

O D

E L

C O

N F

E D

E R

A T

E D

T R

IB

E

S O

F T

H E

S

IL

E T

Z I N

D

IA

N S

S E

S W

A N

A V

E

S

IL

E T

Z

O R

ARCHITECTURAL

TITLE SHEET

JMFMRC

P R

O J E

C T

:2

ARCHITECTURAL SHEET INDEX

A-001 ARCHITECTURAL TITLE SHEET

AD111 LEVEL 1 DEMOLITION PLAN

AD121 LEVEL 1 DEMOLITION REFLECTED CEILING PLAN

A-111 LEVEL 1 FLOOR PLAN

A-121 LEVEL 1 REFLECTED CEILING PLAN

A-131 LEVEL 1 FLOOR FINISH PLAN

A-511 SECTION DETAILS

A-601 DOOR SCHEDULES

SHEET WHERE ITEM IS CUT

ITEM IDENTIFICATION

A-XXX

XX

A-XXX

XX

XX

A-XXX

XX

A-XXX

DETAIL

ELEVATION

ROUGH WOOD

SECTION

XXX

X

UNDISTURBED EARTH

WALL TYPE

REVISION NUMBER

ROOM NUMBER

DOOR NUMBER

WINDOW TYPE

PLYWOOD

METAL

RIGID INSULATION

BATT INSULATION

FINISHED WOOD

STRUCTURAL FILL

BLOCKING

SAND, PLASTER, GROUT

AND&

ANGLEL

AT@

CENTERLINECL

CHANNELu

DIAMETERO

PLATEPL

ABBREVIATIONS SYMBOLS & MATERIALS

SYMBOLS USED AS

ABBREVIATIONS

A

AFF

ACT

ADJ

AB

ALUM

ALT

ANOD

APPROX

ARCH

ASSY

B

BSMT

BATH

BM

BRG

BEDRM

BET

BLDG

BO

BOT

BN

BS

BOS

C

CPT

CLG

CT

CLR

CLST

COL

CONC

CONST

CONT

CONTR

CORR

CJ

CMU

CFCI

D

DEMO

DTL

DIA

DIM

DW

DIV

DL

DR

DN

DS

DWG

DF

D

E

EA

E

ELEC

ELEV

EQ

EQUIP

EXIST

EXP

EJ

EXT

F

FOB

FOC

FOM

ABOVE FINISH FLOOR

ACOUSTICAL CEILING TILE

ADJUSTABLE

ANCHOR BOLT

ALUMINUM

ALTERNATE

ANODIZED

APPROXIMATE

ARCHITECT

ASSEMBLY

BASEMENT

BATHROOM

BEAM

BEARING

BEDROOM

BETWEEN

BUILDING

BOTTOM OF

BOTTOM

BOUNDARY NAILING

BOTH SIDES

BOTTOM OF STRUCTURE

CARPET

CEILING

CERAMIC TILE

CLEAR

CLOSET

COLUMN

CONCRETE

CONSTRUCTION

CONTINUOUS

CONTRACT, CONTRACTOR

CORRIDOR

CONTROL JOINT

CONCRETE MASONRY UNIT

CONTACTOR FURNISHED CONTRACTOR INSTALLED

DEMOLISH, DEMOLITION

DETAIL

DIAMETER

DIMENSION

DISHWASHER

DIVISION

DEAD LOAD

DOOR

DOWN

DOWNSPOUT

DRAWING

DRINKING FOUNTAIN

DRYER

EACH

EAST

ELECTRIC

ELEVATION, ELEVATOR

EQUAL

EQUIPMENT

EXISTING

EXPANSION

EXPANSION JOINT

EXTERIOR

FACE OF BRICK

FACE OF CONCRETE

FACE OF MASONRY

FOS

FIN

FF

FEC

FL

FLR

FD

FT

FTG

FND

FURN

FUT

FBO

FRP

G

GA

GALV

GEN

GL

GWB

GYPC

H

HALL

HDW

HVAC

HT

HM

HORIZ

HWT

HR

I

IBC

INCL

INFO

ID

INSUL

INT

J

JAN

JC

JT

K

KIT

KO

L

LBL

LAM

LNDRY

LAV

LVL

LL

LR

LOC'N

M

MFR

MAS

MO

FACE OF STUDS

FINISH

FINISH FLOOR

FIRE EXTINGUISHER/AND

OR CABINET

FLASHING

FLOOR

FLOOR DRAIN

FOOT, FEET

FOOTING

FOUNDATION

FURNITURE

FUTURE

FURNISHED BY OTHERS

FIBER REINFORCED PANEL

GAUGE

GALVANIZED

GENERAL

GLASS

GYPSUM WALL BOARD

GYPCRETE

HALLWAY

HARDWARE

HEATING, VENTILATING, & AIR

CONDITIONING

HEIGHT

HOLLOW METAL

HORIZONTAL

HOT WATER TANK

HOUR

INTERNATIONAL BUILDING CODE

INCLUDE, INCLUDED (ING)

INFORMATION

INSIDE DIAMETER

INSULATE,INSULATION

INTERIOR

JANITOR

JANITOR'S CLOSET

JOINT

KITCHEN

KNOCK OUT

LABEL

LAMINATED

LAUNDRY

LAVATORY

LEVEL

LIVE LOAD

LIVING ROOM

LOCATION

MANUFACTURER

MASONRY

MASONRY OPENING

MATERIAL

MAXIMUM

MECHANICAL, MECHANICAL ROOM

METAL

MINIMUM

MIRROR

MISCELLANEOUS

NOMINAL

NORTH

NOT APPLICABLE

NOT IN CONTRACT

NOT TO SCALE

NUMBER

ON CENTER

OFFICE

OPENING

OPPOSITE

OUTSIDE DIAMETER

OUTSIDE FACE

OWNER FURNISHED CONTRACTOR INSTALLED

OFWNER FURNISHED OWNER INSTALLED

OUT TO OUT

PAINT, PAINTED

PANEL

PHASE

PLASTIC

PLASTIC LAMINATE

PLATE

PLYWOOD

POLYVINYL CHLORIDE

PREFINISHED

PROPERTY

PREMANUFACTURED

QUANTITY

RADIUS

RAIN WATER LEADER

REFERENCE

REINFORCE, REINFORCEMENT

REFLECTED CEILING PLAN

REQUIRED

REQUEST FOR INFORMATION

REVISION

RISER

ROOF DRAIN

ROOM

ROUGH OPENING

SCHEDULE

SECTION

SAFETY GLASS

SHEATHING

SIMILAR

SLAB ON GRADE

SOUTH

SPECIFICATION

SQUARE

STANDARD

STEEL

STORAGE

STRUCTURAL

SQUARE FEET

SUSPENDED

SELF ADHERED MEMBRANE

MATL

MAX

MECH

MTL

MIN

MIRR

MISC

N

NOM

N

NA

NIC

NTS

NO

O

OC

OFF

OPG

OPP

OD

OF

OFCI

OFOI

O/O

P

PNT

PNL

PH

PLAS

P-LAM

PL

PLYWD

PVC

PF

PROP

PMF

Q

QTY

R

RAD

RWL

REF

REINF

RCP

REQ'D

RFI

REV

R

RD

RM

RO

S

SCHED

SEC

SG

SHTG

SIM

SOG

S

SPEC

SQ

STD

STL

STOR

STRUCT

SF

SUSP

SAM

NORTH ARROW

STEEL

GRAVEL

BRICK VENEER

POURED CONCRETE

CONCRETE BLOCK VENEER

EIFS

KEY NOTE

DEMOLITION NOTE

FINISH TAG

XX

X

X

X

X

SPRAYFOAM INSULATION

DISTURBED EARTH

TELEPHONE

TELEVISION

TEMPERED, TEMPORARY

TONGUE AND GROOVE

TOP OF BRICK

TOP OF SLAB

TOP OF WALL

TOP OF MASONRY

TREAD

TYPICAL

UPWARD ACTING SECTIONAL DOOR

UNIFORM BUILDING CODE

UNLESS NOTED OTHERWISE

UTILITY

VAPOR BARRIER

VENEER

VERTICAL

VERTICAL GRAIN

VINYL COMPOSITION TILE

WAINSCOT

WATER CLOSET

WINDOW

WATERPROOF (ING)

WEATHER RESISTANT BARRIER

WELDED WIRE FABRIC

WELDED WIRE MESH

WEIGHT

WEST, WASHER

WITH

WASHER / DRYER

T

TEL

TV

TEMP

T&G

TOB

TOS

TOW

TOM

T

TYP

U

UAS

UBC

UNO

UTIL

V

VB

VNR

VERT

VG

VCT

W

WSCT

WC

WIN

WP

WRB

WWF

WWM

WT

W

W/

W/D

X.XX - S

X'-X"

ROOM FINISH KEY

CLG

FLR

SILL

WALL S

WALL

E

WALL N

WALL

W

NOTES

BASE

NOTES

EQUIPMENT TAG

CONCRETE MASONRY UNITS

X

1 1

B

B

C

C

D

D

2 2

3 3

4 4

OFFICE

CONFERENCE

OFFICE

R.R.

HALL

300A

R.R.

FOYER

IT ROOM

KITCHEN

HALL

300A

HALL

300A

CLOSET

CLOSET

OFFICE

304 7

DATE:

JACKOLA ENGR. & ARCH., P.C.

WITHOUT THE WRITTEN CONSENT OF

MAY NOT BE USED OR REPRODUCED

IS PROPRIETARY. THIS DOCUMENT

THE INFORMATION CONTAINED HEREIN

REVISIONS:

FOR CONSTRUCTION

KALISPELL

406-755-3208

BOZEMAN

406-586-0707

VANCOUVER

360-852-8746

DRAWN: CHECKED:

info@jackola.com jackola.com

AD111

03/17/2026

B R

O A

D B

A N

D R

E M

O D

E L

C O

N F

E D

E R

A T

E D

T R

IB

E

S O

F T

H E

S

IL

E T

Z I N

D

IA

N S

S E

S W

A N

A V

E

S

IL

E T

Z

O R

LEVEL 1

DEMOLITION

PLAN

JMFMRC

P R

O J E

C T

:2

0 4' 8'2' 1/4" = 1'-0"1

LEVEL 1 DEMOLITION PLAN

LEVEL 1 DEMO KEYNOTES

1 REMOVE EXISTING DOOR, AND FRAME

2 DEMO (E) PARTION BETWEEN KITCHEN AND I.T. ROOM

3 DEMO (E) CASEWORK. (E) APPLICANCES TO BE RELOCATED TO NEW

PANTRY

4 REMOVE (E) BOOKSHELF, SALVAGE TO OWNER

5 REMOVE EXISTING WINDOW

6 NOT INCLUDED IN SCOPE OF WORK

7 (E) FIBER OPTIC POINT OF ENTRY TO REMAIN

8 (E) WATER HEATER TO REMAIN

9 (E) PIPE, DEMO AND RELOCATE PER PLUMBING

10 ALL LV WIRING TO BE REMOVED OR RELOCATED BY OWNER'S

VENDOR. REMOVE PLYWOOD ON WALLS AS POSSIBLE. GC TO

COORDINATE WORK WITH OWNER.

2 2

3 3

4 4

A

A

B

B

C

C

D

D

1 1

A

A

1 1

B

B

C

C

D

D

2 2

3 3

4 4

IT ROOM

OFFICE

CONFERENCE

FOYER

HALL

300A

R.R.

PANTRY

OFFICE

R.R.

HALL

300A

KITCHEN

CLOSET

CLOSET

DATE:

JACKOLA ENGR. & ARCH., P.C.

WITHOUT THE WRITTEN CONSENT OF

MAY NOT BE USED OR REPRODUCED

IS PROPRIETARY. THIS DOCUMENT

THE INFORMATION CONTAINED HEREIN

REVISIONS:

FOR CONSTRUCTION

KALISPELL

406-755-3208

BOZEMAN

406-586-0707

VANCOUVER

360-852-8746

DRAWN: CHECKED:

info@jackola.com jackola.com

AD121

03/17/2026

B R

O A

D B

A N

D R

E M

O D

E L

C O

N F

E D

E R

A T

E D

T R

IB

E

S O

F T

H E

S

IL

E T

Z I N

D

IA

N S

S E

S W

A N

A V

E

S

IL

E T

Z

O R

LEVEL 1

DEMOLITION

REFLECTED

CEILING PLAN

JMFMRC

P R

O J E

C T

:2

0 4' 8'2' 1/4" = 1'-0"1

LEVEL 1 DEMOLITION REFLECTED CEILING PLAN

LEVEL 1 DEMO RCP KEYNOTES

1 DEMO (E) GWB CEILING

DEMO ALL LIGHT FIXTURES

REMOVE ALL ASSOCIATED ELECTRICAL WIRES, BACK TO PANEL

2 NOT INCLUDED IN SCOPE OF WORK

1 1

B

B

C

C

D

D

2 2

3 3

4 4

IT ROOM

OFFICE

CONFERENCE

HALL

300A

HALL

300A

R.R.

FOYER

R.R.

301 PANTRY

OFFICE

" M

IN

CLOSET

CLOSET

MECH

307A

(E)I.1I4.2

"3

I4.1

307A

3' - 8"

(E)E.1

(E)I.1

I4.1

8 1

A-511

SIM

A-511

SIM

M

IN

'X' INDICATES FIRE RATED

LOCATION DESIGNATION

SOUND INSULATION (WHEN PRESENT)

ASSEMBLY HT. (IF NOT FULL HT.)

KEY FOR ASSEMBLY TYPES

A6.1X - S

0'-0"

INTERIOR WALL INFILL

SCALE: 1 1/2" = 1'

(E)I.1

EXTERIORINTERIOR

EXTERIOR WALL IFILL

SCALE: 1 1/2" = 1'

(E)E.1

INTERIOR WALL

SCALE: 1 1/2" = 1'

I4.2

INTERIOR WALL ON 6" CURB

SCALE: 1 1/2" = 1'

I4.1

WALL ASSEMBLY APPROX. WIDTH

GWB (THICKNESS TO MATCH EXISTING)

VAPOR BARRIER (TIE INTO EXISTING)

BATT INSULATION

2X STUD (SIZE TO MATCH EXISTING)

PLYWD SHEATHING (THICKNESS TO MATCH EXISTING)

WEATHER BARRIER (TIE INTO EXISTING)

FINISH (MATERIAL AND PAINT TO MATCH EXISTING

DIRECTLY ADJACENT)

FINISH PER PLAN

NUMBER IN WIDTH SERIES

LOCATION DESIGNATIONS

E: EXTERIOR WALL TYPE

I: INTERIOR WALL TYPE

R: FLOOR TYPE

F: ROOF TYPE

INTERIORINTERIOR

GWB (THICKNESS TO MATCH EXISTING)

2X WOOD STUD @ 16" O.C. (SIZE TO MATCH EXISTING)

GWB (THICKNESS TO MATCH EXISTING)

INTERIORINTERIOR

5/8" GWB

2x4 WOOD STUD @ 16" O.C.

5/8" GWB

FINISH PER PLAN

FINISH PER PLAN

FINISH PER PLAN

FINISH PER PLAN

6"x 6" CONCRETE CURB @ FINISH FLOOR, FINISH PER PLAN

INTERIORINTERIOR

5/8" GWB

2x4 WOOD STUD @ 16" O.C.

5/8" GWB

FINISH PER PLAN

FINISH PER PLAN

DATE:

JACKOLA ENGR. & ARCH., P.C.

WITHOUT THE WRITTEN CONSENT OF

MAY NOT BE USED OR REPRODUCED

IS PROPRIETARY. THIS DOCUMENT

THE INFORMATION CONTAINED HEREIN

REVISIONS:

FOR CONSTRUCTION

KALISPELL

406-755-3208

BOZEMAN

406-586-0707

VANCOUVER

360-852-8746

DRAWN: CHECKED:

info@jackola.com jackola.com

A-111

03/17/2026

B R

O A

D B

A N

D R

E M

O D

E L

C O

N F

E D

E R

A T

E D

T R

IB

E

S O

F T

H E

S

IL

E T

Z I N

D

IA

N S

S E

S W

A N

A V

E

S

IL

E T

Z

O R

LEVEL 1 FLOOR

PLAN

JMFMRC

P R

O J E

C T

:2

0 4' 8'2' 1/4" = 1'-0"1

LEVEL 1 PLAN

LEVEL 1 FLOOR PLAN KEYNOTES

1 NEW SERVER RACKS, O.F.O.I.

2 ADD KEYCARD ACCESS TO NEW DOOR OPENING

3 (E) WATER HEATER

4 NOT INCLUDED IN SCOPE OF WORK

5 THRESHOLD TO BE ON TOP OF 6" CONCRETE CURB

6 INFILL (E) WINDOW OPENING TO MATCH (E) EXTERIOR WALL

ASSEMBLY DIRECTLY ADJACENT. PAINT TO MATCH (E)

EXTERIOR WALL ADJACENT

7 (E) FIBER OPTIC POINT OF ENTRY

8 GIS RACK, O.F.C.I.

9 END OF NEW WALL TO BE ALIGNED WITH EXISTING

10 ALIGN NEW WALL WITH EXISTING FINISH SURFACE

11 INSERT GAS FIRE SUPPRESSION SYSTEM. STAND-ALONE

SYSTEM TO BE DESIGN-BUILT BY FIRE SUPPRESSION

CONTRACTOR.

1 1/2" = 1'-0"

ASSEMBLIES

1 BULLETIN 1 03/24/26

1 1

B

B

C

C

D

D

2 2

3 3

4 4

IT ROOM

OFFICE

CONFERENCE

FOYER

HALL

300A

R.R.

PANTRY

OFFICE

R.R.

HALL

300A

PT-1

8' - 0"

ACT-1

7' - 6"

CLOSET

CLOSET

302 1

BOS

(E)SLOPED

CEILING

(E )S

LO

P

E

IL

IN

G

(E)SLOPED

CEILING

(E )S

LO

P

IL

IN

G

(TYP.)

CEILING PLAN LEGEND

GWB-1

GYPSUM WALL BOARD

PT-1

X'-X"

HEIGHT A.F.F.

FINISH, REFER TO FINISH SCHEDULE

ACT-1

ACOUSTIC CEILING TILE

CEILING TAG LEGEND

2"

3"

2"

CHANNEL MOLDING

FASCIA

MOLDING

POP RIVET THIS

SIDE ONLY

STABILIZER BAR, OR OTHER

SUITABLE SYSTEM, TO KEEP

PERIMETER COMPONENTS FROM

SPREADING APART.

MAIN BEAM

MAIN BEAMS OR

CROSS TEES

SEISMIC SEPARATION JOINT

SEISMIC DETAILS

PERIMETER

SUPPORT WIRES # 12

NOTES:

1. CEILING AREAS OVER 1,000 SF MUST HAVE

HORIZONTAL RESTRAINT WIRE OR RIGID BRACING

2. USE HEAVY DUTY GRID SYSTEM

3. USE PERIMETER SUPPORT WIRES

4. CEILINGS WITHOUT RIGID BRACING MUST HAVE 2"

OVERSIZED TRIM RINGS FOR SPRINKLERS AND

OTHER PENETRATIONS

5. GRID MUST BE ATTACHED TO 2 ADJACENT WALLS,

OPPOSITE WALLS MUST HAVE 3/4" CLEARANCE

6. MIN 2" WALL MOLDING

"ATTACHED""UNATTACHED"

ANGLE

MOLDING

8" M

AX.

8" M

AX.

MIN

1 1/2

3/4"MIN AT UNATTACHED WALLS

MIN 2"

DATE:

JACKOLA ENGR. & ARCH., P.C.

WITHOUT THE WRITTEN CONSENT OF

MAY NOT BE USED OR REPRODUCED

IS PROPRIETARY. THIS DOCUMENT

THE INFORMATION CONTAINED HEREIN

REVISIONS:

FOR CONSTRUCTION

KALISPELL

406-755-3208

BOZEMAN

406-586-0707

VANCOUVER

360-852-8746

DRAWN: CHECKED:

info@jackola.com jackola.com

A-121

03/17/2026

B R

O A

D B

A N

D R

E M

O D

E L

C O

N F

E D

E R

A T

E D

T R

IB

E

S O

F T

H E

S

IL

E T

Z I N

D

IA

N S

S E

S W

A N

A V

E

S

IL

E T

Z

O R

LEVEL 1

REFLECTED

CEILING PLAN

JMFMRC

P R

O J E

C T

:2

0 4' 8'2' 1/4" = 1'-0"1

LEVEL 1 REFLECTED CEILING PLAN

LEVEL 1 RCP KEYNOTES

1 NOT INCLUDED IN SCOPE OF WORK

2 PATCH AND PAINT (E) GWB TO ACCOMIDATE FOR WING WALL

3 ALL LIGHTING, PER ELECTRICAL

1 1/2" = 1'-0"

HUNG CEILING DETAILS - SEISMIC

1 1

VCT-1

N/A

PT-1

PT-1

PT-1

PT-1

RB-1

B

B

C

C

D

D

2 2

3 3

4 4

IT ROOM

PANTRY

A-1312

MECH

307A

VS-1

N/A

PT-1

PT-1

PT-1

PT-1

VS-1

LVP-1

N/A

PT-1

PT-1

PT-1

PT-1

RB-1

LA

M

-2

CPT-1

LVP-1

LAM-1

LAM-2

LAM-1

A-131

Sim

39" 39" 39"

1. COUNTERTOP PER INTERIOR DRAWINGS

2. 3/4" MDF BACK SPLASH LAMINATE CLAD

3. CABINET AND DRAWER PULLS, STAINLESS STEEL

4. 3/4" MELAMINE COVERED ADJUSTABLE SHELF

ON RECESSED STANDARDS

5. USE CONCEALED EUROPEAN HINGES

6. FLUSH OVERLAY LAMINATE DOORS AND

DRAWER FRONTS, SEE INT. ELEVATIONS

7. 3/4" MELAMINE FACING - ALL EXPOSED

INTERIOR SURFACES

9. BASE FINISHED AS SCHEDULED

P E

R E

LE

V

A T

IO

N

S

1' - 0"

2' - 0"

P E

R E

LE

V

A T

IO

N

S

8. DRAWER BODIES 1/2" MELAMINE FACED W/

FULL EXTENSION GLIDES

/2

/8

/2

/1

(E) CARPET

EXISTING SUB FLOOR

VINYL TRANSITION STRIP

LVP RESILIENT FLOORING

EQ EQ

TRANSITION @

CENTERLINE OF DOOR @

DOOR LOCATIONS

(E) CARPET

EXISTING SUB FLOOR

VINYL TRANSITION STRIP

VCT

DATE:

JACKOLA ENGR. & ARCH., P.C.

WITHOUT THE WRITTEN CONSENT OF

MAY NOT BE USED OR REPRODUCED

IS PROPRIETARY. THIS DOCUMENT

THE INFORMATION CONTAINED HEREIN

REVISIONS:

FOR CONSTRUCTION

KALISPELL

406-755-3208

BOZEMAN

406-586-0707

VANCOUVER

360-852-8746

DRAWN: CHECKED:

info@jackola.com jackola.com

A-131

03/17/2026

B R

O A

D B

A N

D R

E M

O D

E L

C O

N F

E D

E R

A T

E D

T R

IB

E

S O

F T

H E

S

IL

E T

Z I N

D

IA

N S

S E

S W

A N

A V

E

S

IL

E T

Z

O R

LEVEL 1 FLOOR

FINISH PLAN

JMFMRC

P R

O J E

C T

:2

FINISH SCHEDULE (SUBMIT FINISH SAMPLES FOR OWNER APPROVAL, TYPICAL)

TAG KEY COLOR MANUFACTURER STYLE NOTE

ACT-1 ACOUSTICAL CEILING TILE WHITE ARMSTRONG 24 x 48 ITEM NO 1943 TECHZONE WITH ULTIMA FIELD PANELS, SQUARE LAY-IN

CPT-1 EXISTING CARPET EXISTING EXISTING EXISTING EXISTING

LAM-1 LAMINATE CABINETRY 931-WG LIGHT ASH LAMINART VENEER ART WEATHERD GRAIN FINISH FLAT CUT/RANDOM MATCHED

LAM-2 LAMINATE COUNTERTOP P271 CA FRESH MIST ABORITE ADD MATCHING EDGE BANDING

LVP-1 VINYL PLANK NOLV252005 GRADE TAS CONTRACT LEVELS 2.5 20 MIL GLUE DOWN USE MANUFACTURE RECOMENDED GLUE AND SUBFLOOR PREP

PT-1 PAINT SW7005 PURE WHITE SHERWIN WILLIAMS SATIN

RB-1 RUBBER BASE 110 BROWN ROPPE 700 SERIES 4" STANDARD TOE BASE 5/8"

VCT-1 VINYL COMPOSITE TILE (ANTI-STATIC) 51953 EXCELON SDT PEARL WHITE ARMSTRONG 12"x12"x1/8"

VS-1 VINYL SHEET 952 BEACHY ROPPE OBSIDIAN VINYL SHEET 6" FLASH COVE BASE WITH STAINLESS STEEL CAP

FLOOR

WIN

SILL

WALL

WALL

WALL

WALL

NOTES

BASE

0 4' 8'2' 1/4" = 1'-0"1

LEVEL 1 FLOOR FINISH PLAN

ROOM FINISH KEY

FINISH PLAN KEYNOTES

1 REFRIGERATOR FROM EXISTING KITCHENETTE

2 MATCH PAINT WHERE NEW WALL MEETS EXISTING, OTHERWISE

BREAK COLOR AT INSIDE CORNER WHEN POSSIBLE

3 PROVIDE FINISH PANEL FOR EXPOSED ENDS OF UPPERS AND BASE

CABS

3/8" = 1'-0"

PANTRY

3/4" = 1'-0"

CABINET SECTION

1 1/2" = 1'-0"

TRANSITION-CPT-1/LVP-1

1 1/2" = 1'-0"

TRANSITION CPT-1/VCT-1

(E) SLAB

(N) CONCRETE CURB W/ #4 CONTINUOUS BAR

THROUGH CENTER OF CURB

6"

TYP

R 1"

#4X6" REBAR WITH 3" MINIMUM EMBED DEPTH WITH

HILTI-HY 200-R V3 EPOXY @ 48" O.C. AND EACH END/CORNER

E M

B E

D D

E P

T H

PRESSURE TREATED SILL PLATE WITH

SIMPSON 3" LONG PDPA POWER-

DRIVEN PINS @ 16" ON CENTER

2X DOUGLAS FIR/LARCH #2

STUDS @ 16" ON CENTER

NOTES:

1. ENSURE PROJECT CONCRETE MIX DESIGN MEETS THE FOLLOWING CRITERIA:

a. 28-DAY MINIMUM COMPRESSIVE STRENGTH - 4000 PSI

b. SLUMP (MAXIMUM/MINIMUM) - 5 INCHES/3 INCHES

c. MAXIMUM WATER TO CEMENT RATIO - 0.45

d. MAXIMUM AIR CONTENT PERCENTAGE - 3%

2. ALL REINFORCING BARS SHALL BE DEFORMED BARS AT LEAST GRADE 60.

3. PROVIDE A MINIMUM CLEAR COVER OF 3/4" FOR ALL REINFORCING BARS.

4. PRESSURE TREATED SILL TO MEET THE PRESERVATION REQUIREMENTS OF

AWPA U1

WALL FINISH PER PLAN

(E) ROOF FRAMING

B: PERP TO ROOF FRAMING

KEY CURB INTO (E) SLAB

DROPPED CEILING PER PLAN

EXISTING ROOF FRAMING

/2

G

A P

2X BLOCKING @ 24" O.C.

DS CLIPS @ 16" O.C.

TO FIRST FASTENER

16"

A: PAR TO ROOF FRAMING

DROPPED CEILING PER PLAN

TO FIRST FASTENER

16"

DS CLIPS @ 16" O.C.

/2

G

A P

SDPW19600 SCREW TO EACH

FRAMING MEMBER (24" O.C. MAX)

/4

/4

SDPW19600 SCREW TO EACH

BLOCKING MEMBER (24" O.C. MAX)

NOTE: DO NOT PENETRATE BOTTOM SURFACE OF (E) SLAB

WATERPROOFING AND SUBSLAB PLUMBING.

EXISTING SIDING

METAL OVER BLOCK, PAINTED TO

MATCH EXISTING FLASHING/SIDING

MOUNTING BLOCK

FOR PENETRATION

FIXTURE (ROOF DRAIN

NOZZLE SHOWN AS

EXAMPLE)

FLASHING, PAINTED TO MATCH

EXISTING FLASHING/SIDING

SIDING MANUFACTURER

APPROVED SEALANT AROUND

PERIMETER OF BLOCK

NOTE:

1. SEE PLUMBING FOR EXTERIOR PLUMBING FIXTURES.

2. SEE ELECTRICAL FOR EXTERIOR ELECTRICAL FIXTURES.

EXISTING SIDING

METAL FLASHING, PAINTED TO MATCH EXISTING FLASHING/SIDING

WRB, WRAP OVER FLASHING

BACKER ROD

AND SEALANT

METAL OVER BLOCK, PAINTED TO MATCH EXISTING FLASHING/SIDING

MOUNTING BLOCK

(FACE OF BLOCK TO BE FLUSH WITH FACE OF SIDING)

PENETRATION FIXTURE FASTENED TO BLOCK (ROOF

DRAIN NOZZLE, ELECTRICAL BOX, HOSE BIB, ETC.)

SIDING MANUFACTURER APPROVED SEALANT AND

BACKER ROD

A

A

ELEVATION SECTION A

DATE:

JACKOLA ENGR. & ARCH., P.C.

WITHOUT THE WRITTEN CONSENT OF

MAY NOT BE USED OR REPRODUCED

IS PROPRIETARY. THIS DOCUMENT

THE INFORMATION CONTAINED HEREIN

REVISIONS:

FOR CONSTRUCTION

KALISPELL

406-755-3208

BOZEMAN

406-586-0707

VANCOUVER

360-852-8746

DRAWN: CHECKED:

info@jackola.com jackola.com

A-511

03/17/2026

B R

O A

D B

A N

D R

E M

O D

E L

C O

N F

E D

E R

A T

E D

T R

IB

E

S O

F T

H E

S

IL

E T

Z I N

D

IA

N S

S E

S W

A N

A V

E

S

IL

E T

Z

O R

SECTION

DETAILS

P R

O J E

C T

:2

1 1/2" = 1'-0"

NEW CURB AND WALL SUPPORT DETAIL

1 1/2" = 1'-0"

SIDING PENETRATION DETAIL

INTERIOR FLUSH

PANEL DOOR

S E

E S

C H

E D

U

LE

SEE SCHEDULE

WD - WOOD

DOOR

WD TRIM TO MATCH EXISTING

WD JAMB

INSULATE ALL VOIDS, SHIM

AS REQ'D FOR INSTALLATION

PERIMETER SEAL TYP.

WALL TYPE PER PLAN

WD TRIM TO MATCH EXISTING

DOOR

WD JAMB

INSULATE ALL VOIDS, SHIM

AS REQ'D FOR INSTALLATION

PERIMETER SEAL TYP.

WALL TYPE PER PLAN

WD TRIM TO MATCH EXISTING WD TRIM TO MATCH EXISTING

DATE:

JACKOLA ENGR. & ARCH., P.C.

WITHOUT THE WRITTEN CONSENT OF

MAY NOT BE USED OR REPRODUCED

IS PROPRIETARY. THIS DOCUMENT

THE INFORMATION CONTAINED HEREIN

REVISIONS:

FOR CONSTRUCTION

KALISPELL

406-755-3208

BOZEMAN

406-586-0707

VANCOUVER

360-852-8746

DRAWN: CHECKED:

info@jackola.com jackola.com

A-601

03/17/2026

B R

O A

D B

A N

D R

E M

O D

E L

C O

N F

E D

E R

A T

E D

T R

IB

E

S O

F T

H E

S

IL

E T

Z I N

D

IA

N S

S E

S W

A N

A V

E

S

IL

E T

Z

O R

DOOR

SCHEDULES

JMFMRC

P R

O J E

C T

:2

DOOR SCHEDULE

DOOR FROM TO SIZE FIRE RATING ELEVATION TYPE DOOR MAT. FRAME MAT. GLAZING/LITES HARDWARE DOOR STOP (W:WALL, F:FLOOR) REMARKS

307 HALL 300A IT ROOM 307 3' 0" x 6' 8" x 1 3/4" N/A A WD WD N/A HDW-1

STOREROOM

W KEYCARD ACCESS

307A MECH 307A IT ROOM 307 2' 6" x 6' 6" x 1 3/4" N/A A WD WD N/A HDW-1

STOREROOM

W PLACED ON 6" CONCRETE CURB

0 4' 8'2' 1/4" = 1'-0"

DOOR LEGEND

DOOR HARDWARE

HDW HARDWARE

HDW-1 STOREROOM 1 1/2 PR BUTTS

1 LOCKSET ANSI F86/

BHMA D

1 WALL STOP

1 SET SILENCERS

GENERAL NOTES:

1. HARDWARE:

HINGES: BY STANLEY, HAGER OR APPROVED

EQUAL.

LOCKSETS: BY SARGENT, ADAMS-RITE, SCHLAGE

OR APPROVED EQUAL .

CLOSER: BY LCN, DORMA OR APPROVED EQUAL.

WEATHERSTRIPPING, THRESHOLD, AND

SWEEP: BY PEMKO OR APPROVED EQUAL

KEYWAY - TO BE MATCH EXISTING

2. CONTRACTOR RESPONSIBLE TO NOTIFY

DESIGNER OF SUBSTITUTIONS FOR NOTED

HARDWARE.

3. DOOR & DOOR HARDWARE SUBMITTAL

REQUIRED.

4. HOLLOW METAL DOORS: 18 GAUGE METAL.

HOLLOW METAL DOOR FRAMES: 16 GAUGE

AND WELD UP.

HARDWARE COLOR: BRUSHED STAINLESS STEEL

1 1/2" = 1'-0"

INT. WD JMB DTL

1 1/2" = 1'-0"

INT. WD HD DTL

CO2

CO

H

HS

NO2

S

TH

TS

T

MS

C

LT

CHWS

DV-E

CWR

CWS

HWR

HWS

DV-I

CHWR CHILLED WATER RETURN

CHILLED WATER SUPPLY

DIRECT VENT - EXHAUST

CONDENSER WATER RETURN

CONDENSER WATER SUPPLY

HEATING WATER RETURN

HEATING WATER SUPPLY

DIRECT VENT - INTAKE

REF-L

REF-S

REFRIGERANT-LIQUID

REFRIGERANT-SUCTION

CAP

REF-HG REFRIGERANT-HOT GAS

PLUMBING AND PIPING SYMBOLS

KEYNOTE

CONTINUATION SYMBOL

NUMBER OF SHEET WHERE DETAIL APPEARS

NUMBER OF DETAIL ON SHEET

REVISION NUMBER - SHOWN ON PLANS

GENERAL DRAWING SYMBOLS

ROOM NAME AND NUMBER

POINT WHERE NEW CONNECTS TO EXISTING

ITEM TO BE DEMOLISHED

AREA NOT IN CONTRACT

PIPE RISE

PIPE DROP

PIPE TEE

* NOTE *

THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET

MAY OR MAY NOT BE USED IN THIS SET OF DRAWINGS.

Room

16"x8"

16"/8"

(E)

B

D

C

16"Ø

E/A

O/A

T/A

L/A

R/A

S/A

EXHAUST AIR

OUTSIDE AIR

RELIEF AIR

RETURN AIR

SUPPLY AIR

TRANSFER AIR

GRILLES, REGISTERS & DIFFUSERS TAG

CFM

THROW-150FPM/ 100FPM/ 50FPM

NECK SIZE / MODULE SIZE

EXISTING DUCT TAG

OVAL DUCT SIZE TAG

(WIDTH / HEIGHT)

SQUARE DUCT SIZE TAG

(WIDTH x HEIGHT)

HVAC SYMBOLS

RECTANGULAR

SUPPLY/OUTSIDE AIR DUCT RISE

RECTANGULAR

RETURN/TRANSFER AIR DUCT RISE

MECHANICAL EQUIPMENT TAGS

ROUND DUCT SIZE TAG

(DIAMETER)

LINEAR DIFFUSER TAG

CFM

TYPE (SEE SCHEDULE) NUMBER OF SLOTS /

ACTIVE SLOT LENGTH (PLENUM LENGTH) /

NECK SIZE

DUCT BEING

DEMOLISHED

ELEVATION (CENTER OF FACE)

ROUND SUPPLY/OUTSIDE

AIR DUCT RISE

ROUND RETURN/TRANSFER

AIR DUCT RISE

RECTANGULAR EXHAUST/RELIEF

AIR DUCT RISE

ROUND EXHAUST/RELIEF

AIR DUCT RISE

DROP

DROP

DROP

DROP

DROP

DROP

G-E/A GREASE EXHAUST AIR

S-E/A SMOKE EXHAUST AIR

EQUIPMENT BY OTHERS

(REFER TO OTHER DISCIPLINE

FOR ADDITIONAL INFORMATION)

EXISTING EQUIPMENT

TO REMAIN

FLUE EXHAUST GAS FLUE

C/A COMBUSTION AIR

S-O/A CONDITIONED OUTSIDE AIR

Ø ROUND

ABV ABOVE

AC AIR CONDITIONING

AD AREA DRAIN

ADD ADDENDUM

AFF ABOVE FINISHED FLOOR

AFUE ANNUAL FUEL UTILIZATION EFFICIENCY

ALT ALTERNATE

AP ACCESS PANEL

ARCH ARCHITECT/ARCHITECTURAL

BFF BELOW FINISHED FLOOR

BLW BELOW

BTU BRITISH THERMAL UNITS

BTUH BRITISH THERMAL UNITS PER HOUR

CAP CAPACITY

CB CATCH BASIN

CFM CUBIC FEET PER MINUTE

CLG CEILING

CO CLEAN OUT

CW COLD WATER

D DEGREE

DB DRY BULB

DIA DIAMETER

DN DOWN

DW DISTILLED WATER

EA EACH

EAT ENTERING AIR TEMPERATURE

ELEC ELECTRICAL

EQUIP EQUIPMENT

EWC ELECTRIC WATER COOLER

EWT ENTERING WATER TEMPERATURE

E/A EXHAUST AIR

EXIST EXISTING

F DEGREES FAHRENHEIT

FCO FLOOR CLEAN OUT

FD FLOOR DRAIN

FD FIRE DAMPER

FDV FIRE DEPARTMENT VALVE

FL FLOOR

FO FUEL OIL

FOV FUEL OIL VENT

FOR FUEL OIL RETURN

FOS FUEL OIL SUPPLY

FPM FEET PER MINUTE

FS FLOOR SINK

FT FOOT/FEET

FTR FIN TUBE RADIATION

GAL GALLON

GC GENERAL CONTRACTOR

GPM GALLONS PER MINUTE

GW GREASE WASTE

HB HOSE BIB

HP HORSE POWER

HTG HEATING

HTR HEATER

HW HOT WATER

HYD HYDRANT

ID INDIRECT

IN INCH

INV INVERT

LB POUND

LB/HR POUNDS PER HOUR

LAT LEAVING AIR TEMPERATURE

LP LOW PRESSURE

LPG LIQUEFIED PETROLEUM GAS

LVR LOUVER

LWT LEAVING WATER TEMPERATURE

M/A MIXED AIR

MAX MAXIMUM

MBH ONE THOUSAND BTU PER HOUR

MCF ONE THOUSAND CUBIC FEET

MD MOTORIZED DAMPER

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MTR MOTOR

MU/A MAKE-UP/AIR

NC NOISE CRITERIA

NC NORMALLY CLOSED

NIC NOT IN CONTRACT

NO NUMBER

NO NORMALLY OPEN

NTS NOT TO SCALE

O OXYGEN

O/A OUTSIDE AIR

ORD OVERFLOW ROOF DRAIN

PD PRESSURE DROP

PIV POST INDICATOR VALVE

PLBG PLUMBING

PRESS PRESSURE

PRV PRESSURE REDUCING VALVE

PSI POUNDS PER SQUARE INCH

PSIG POUNDS PER SQUARE INCH GAUGE

PWR POWER

R DUCT RISER

R/A RETURN AIR

RCP RADIANT CEILING PANEL

RD ROOF DRAIN

REC RECESSED

RED REDUCER

RH RELATIVE HUMIDITY

RL/A RELIEF AIR

RM ROOM

RPM REVOLUTIONS PER MINUTE

RW RAIN WATER

SF SQUARE FOOT

S/A SUPPLY AIR

SAN SANITARY

SF SQUARE FOOT

SD SMOKE DAMPER

SM SURFACE MOUNT

SP STANDPIPE

SP STATIC PRESSURE

STM STEAM

T THERMOSTAT

TD TEMPERATURE DROP

TDR TRENCH DRAIN

TEMP TEMPERATURE

TYP TYPICAL

UG UNDERGROUND

VAC VACUUM

V VENT

VAV VARIABLE AIR VOLUME

VENT VENTILATION

VTR VENT THROUGH ROOF

W WASTE

WB WET BULB

WCO WALL CLEAN OUT

WH WALL HYDRANT

AC AIR CONDITIONING UNIT

AHU AIR HANDLING UNIT

AS AIR SEPARATOR

B BOILER

BP BOILER PUMP

CC COOLING COIL

CH CHILLER

CT COOLING TOWER

CU CONDENSING UNIT

CWP CONDENSER WATER PUMP

CHWP CHILLED WATER PUMP

DBP DOMESTIC WATER BOOSTER PUMP

DCP DOMESTIC WATER CIRCULATING PUMP

DF DUCT FURNACE

DH DUCT HEATER

EF EXHAUST FAN

EH ELECTRIC HEATER

ERV ENERGY RECOVERY VENTILATOR

ET EXPANSION TANK

F FURNACE

FC FAN COIL

FP FIRE PUMP

GI GREASE INTERCEPTOR

GRV GRAVITY ROOF VENTILATOR

HP HEAT PUMP

HS HYDRAULIC SEPARATOR

HWP HEATING WATER PUMP

HX HEAT EXCHANGER

HRV HEAT RECOVERY VENTILATOR

MAU MAKE-UP AIR UNIT

P PUMP

RF RETURN FAN

RTU ROOF TOP UNIT

SD SLIM DUCT

SEP SEWAGE EJECTOR PUMP

SF SUPPLY FAN

SP SUMP PUMP

UH UNIT HEATER

VAV VARIABLE AIR VOLUME BOX

WH WATER HEATER

WM WALL MOUNT

EQUIPMENT ABBREVIATIONS

48"x2 1/2"

400LS-1

8"x8"/24"x24" 300*S-1

400* 12"Ø/---

S-1

LINEAR BAR GRILLE

LINEAR SLOT DIFFUSER

PERFORATED DIFFUSER

WITH DEFLECTORS

ROUND DIFFUSER WITH

ADJUSTABLE PATTERNS

LOUVERED DOUBLE

DEFLECTION GRILLE

12"x10"/---

500S-2

TYPE (SEE SCHEDULE)

10"Ø/24"x24" H-5/7/1422

400*S-2

3-CONE DIFFUSER

THROW PATTERN

MAX NC RATING

1 / 4' - 0" /9"/5"

200LS-2

8' - 0" AFF

1 / 4' - 0" /9"/5"

200LS-2

18' - 0"

1 / 4' - 0" /9"/5"

200LS-2

SECTION TOTAL TRACK LENGTH

12"x10"/24x12 500R-2

LOUVERED GRILLE

12"x10"/24x24

500R-2

EGGCRATE RETURN

GRILLE

BOTTOM OF EQUIPMENT

ELEVATION

590 lb

RTU-XX

4.0 ton

RTU-XX

115 CFH

RTU-XX

HEATING COIL FLOW

OPERATING WEIGHT

NOT INCLUDING CURB

FUEL INPUT

GAS PIPE FLOW

NOMINAL COOLING

CAPACITY ROOFTOP UNIT

PIPE ACCESSORY TAGS

BALANCING VALVE

1/4 TURN BALL VALVE

CHECK VALVE

3-WAY MIXING VALVE

MOTORIZED CONTROL VALVE

3 WAY MOTORIZED CONTROL

VALVE

PRESSURE REDUCING VALVE

REFRIGERANT SOLENOID VALVE

BUTTERFLY VALVE

2" BALANCING

2" SHUTOFF

2" CHECK

2" TMV

2" M-CNTRL

2" 3-WAY CNTRL

2" PRV

3/8" SOLENOID

2" BUTTERFLY

EQUIPMENT ID

SYMBOL

BBB

INLET COLLAR DAMPER

MANUAL BALANCING DAMPER

BACKDRAFT DAMPER

COMBINATION FIRE/SMOKE

DAMPER

VAV-XX

10' - 0"

(E)VAV-XX

VAV-XX

Htg: 3.7 GPM

VAV-XX

GWR GEOTHERMAL WATER RETURN

GWS GEOTHERMAL WATER SUPPLY

BUILDING MECHANICAL SYSTEMS ARE DESIGNED IN ACCORDANCE WITH THE FOLLOWING CODES:

• 2025 OREGON MECHANICAL SPECIALTY CODE

• 2023 OREGON PLUMBING SPECIALTY CODE

• 2025 OREGON ENERGY EFFICIENCY SPECIALTY CODE

CODE COMPLIANCE

PIPING INSULATION SCHEDULE - INTERNATIONAL ENERGY CONSERVATION CODE

FLUID OPERATING

TEMPERATURE RANGE AND

USAGE [°F]

CONDUCTIVITY

[BTU-IN/HR-FT2-°F]

MEAN RATING

TEMPERATURE [°F]

INSULATION CONDUCTIVITY NOMINAL PIPE OR TUBE SIZE [INCHES]

< 1

1 TO

< 1-1/2

1-1/2

TO < 4

4 TO < 8 >=8

141 - 200

105 - 140

40 - 60

0.25 - 0.29

0.21 - 0.28

0.21 - 0.27

1.5

1.0

0.5

1.5

1.0

0.5

2.0

1.5

1.0

2.0

1.5

1.0

2.0

1.5

1.0

F

S

M

FIRE DAMPER

SMOKE DAMPER

MOTORIZED DAMPER

PIPE SYMBOLS

DAMPER TAGS

MECHANICAL CONTROL DEVICE TAGS

ABBREVIATIONS

1. INSTALLATION OF THE MECHANICAL SYSTEM SHALL BE BY A

LICENSED CONTRACTOR PER THE STATE BUILDING, MECHANICAL

ENERGY, FIRE, PLUMBING AND HEALTH CODES, AND REGULATIONS

AS ADOPTED BY LOCAL JURISDICTIONS.

2. ALL EQUIPMENT SHALL BE THE CAPACITY AND TYPE AS SHOWN ON

THE EQUIPMENT SCHEDULE AND SHALL BE THE LISTED

MANUFACTURER AND MODEL NUMBER OR SHALL BE AN EQUAL

APPROVED BY THE OWNER/ENGINEER.

3. CONTRACTOR IS TO BRING UP THE DISCREPANCIES AND ITEMS

WHICH ARE NOT SPECIFICALLY CALLED FOR OR SHOWN BUT ARE

REQUIRED FOR A COMPLETE MECHANICAL SYSTEM. ALL SUCH

ITEMS REQUIRED FOR A COMPLETE SYSTEM READY FOR THE

OWNER'S BENEFICIAL USE SHALL BE FURNISHED AND INSTALLED

INCLUDING ALL SUCH DISCREPANCY ITEMS MENTIONED ABOVE,

AT NO ADDITIONAL COST TO THE OWNER AND PER LOCAL CODES,

MANUFACTURER'S RECOMMENDATIONS AND APPLICABLE

STANDARDS WITH THE ARCHITECT/ENGINEER'S APPROVAL.

4. ALL EQUIPMENT SUPPLIED FOR THESE SPECIFICATIONS SHALL BE

FREE FROM DEFECTS IN MATERIAL, WORKMANSHIP, AND TITLE,

AND SHALL BE OF THE KIND AND QUALITY DESCRIBED HEREIN. IF

IT APPEARS WITHIN ONE YEAR FROM DATE OF FINAL ACCEPTANCE

THAT EQUIPMENT DOES NOT MEET THE WARRANTIES ABOVE, THE

CONTRACTOR SHALL IMMEDIATELY CORRECT ANY DEFECT AND

SHALL RESTORE THE SYSTEM TO THE ORIGINAL SATISFACTORY

CONDITIONS AT HIS EXPENSE. THE FOREGOING WARRANTY IS

EXCLUSIVE AND IN LIEU OF OTHER WARRANTIES, WHETHER

WRITTEN, ORAL, IMPLIED, OR STATUTORY. NO WARRANTY OR

MERCHANT ABILITY OF FITNESS FOR PURPOSE SHALL APPLY (THE

WARRANTY SHALL START FROM THE TIME OF

ARCHITECT/ENGINEER'S FINAL ACCEPTANCE).

5. COORDINATE THE CONSTRUCTION SCHEDULE WITH THE GC AND

PERFORM ALL REQUIRED WORK IN STRICT ACCORDANCE WITH

THE OWNER'S SCHEDULE.

6. MECHANICAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL

REQUIRED PERMITS AND CERTIFICATES REQUIRED BY THE

AUTHORITIES HAVING JURISDICTION.

7. HVAC NOTES:

A. PROVIDE FLEXIBLE CONNECTION IN ALL DUCTS CONNECTING

TO AIR MOVING EQUIPMENT AS CLOSE TO FAN AS POSSIBLE.

FLEXIBLE CONNECTION SHALL CONSIST OF 6" OR MORE OF

AIR TIGHT, FIRE PROOF FLEXIBLE NEOPRENE COATED WOVEN

FIBROUS GLASS MATERIAL. VENT FABRICS, INC. OR

APPROVED EQUAL.

B. ALL MAIN TRUNK AND BRANCH TAKEOFF DUCTWORK SHALL

BE SHEET METAL. FLEXIBLE DUCT IS ALLOWED ON LAST 6'

SERVING GRDs. FIBERGLASS DUCTWORK SHALL NOT BE

USED.

C. ALL SUPPLY & RETURN FLEXIBLE DUCTS CONNECTING TO

GRILLES, REGISTERS AND DIFFUSERS SHALL BE CONSTRUCTED

OF DOUBLE LAMINATION OF POLYESTER ENCAPSULATED

STEEL WIRE HELIX FOR INNER CORE HIGH DENSITY

FIBERGLASS INSULATION AND GRAY POLYESTER FILM WITH

SPIRAL REINFORCEMENTS, EQUAL TO ATCO-70 SERIES (MIN.

POS. PRESS. = 6' W.C. NEG. PRESS. = 0.75" W.C. & R=5.79).

D. SEAL ALL DUCTWORK JOINTS PER SMACNA CLASS C FOR

SYSTEMS UP TO 2 IN W.G. AND SEAL ALL JOINTS AND SEAMS

PER SMACNA CLASS B FOR SYSTEMS GREATER THAN 2 IN W.G.

E. ALL EQUIPMENT, DUCTWORK AND PIPING SHALL BE

STRUCTURALLY SUPPORTED AND SECURELY FASTENED TO

BUILDING STRUCTURE IN AN ACCEPTABLE MANNER TO

OWNER, ARCHITECT, ENGINEER AND LOCAL JURISDICTION

AND SHALL BE SEISMICALLY BRACED PER THE SMACNA

AND/OR REQUIRED BY LOCAL JURISDICTIONS.

F. PROVIDE LOCKABLE VOLUME DAMPERS IN ALL TAKEOFFS.

G. DUCT HANGERS, SUPPORTS AND METHODS OF INSTALLATION

SHALL CONFORM TO ASHRAE & SMACNA

RECOMMENDATIONS.

H. DUCT SIZES SHOWN ON PLANS INDICATE INSIDE FREE AREA.

I. ALL DUCTWORK SHALL BE CLASS-1 AIR DUCT AS APPROVED

BY U.L.-181.

J. ALL SQUARE ELBOWS SHALL HAVE TURNING VANES.

K. DUCT INSULATION SHALL BE PROVIDED PER DUCT

INSULATION SCHEDULE ON M0.00.

8. ALL FIRE RATED STRUCTURE SHALL BE FIRE DAMPERED AS

REQUIRED BY THE JURISDICTION.

9. FLEXIBLE DUCTS SHALL HAVE MAXIMUM 6 FEET LENGTH UNLESS

SHOWN OTHERWISE AND SHALL NOT PENETRATE THROUGH ANY

FIRE RATED WALLS. DO NOT INSTALL FLEXIBLE DUCTS WITHIN 6

FEET OF HEATING ELEMENT.

10. HVAC SYSTEM SHALL BE STARTED UP AND FUNCTIONALLY TESTED

BY MECHANICAL CONTRACTOR. MECHANICAL CONTRACTOR

SHALL CONFIRM THAT ALL HVAC SYSTEMS ARE READY FOR

TESTING, ADJUSTING, AND BALANCING. HVAC SYSTEMS SHALL BE

TESTED, ADJUSTED, AND BALANCED (TAB) BY CONTRACTOR

CERTIFIED BY THE AABC, NEBB, OR OTHER APPROVED AGENCY.

REFRIGERATION PIPING SHALL BE TESTED UNDER PRESSURE AND

PROVEN TO BE LEAK FREE. REFRIGERATION SYSTEM SHALL BE

STARTED UP AND BROUGHT DOWN TO DESIGN TEMPERATURE.

11. MECHANICAL, HVAC, AND PLUMBING ELEMENTS SHALL AT NO

TIME COME IN CONTACT WITH CEILING CONSTRUCTION EXCEPT

AS NECESSARY PENETRATIONS MAY REQUIRE. ESCUTCHEONS

SHALL BE USED ON ALL VISIBLE PENETRATIONS

12. ACCESS SHALL BE PROVIDED BY GC AS REQUIRED FOR

INSTALLATION AND MAINTENANCE OF MECHANICAL,ELECTRICAL,

AND OTHER ELEMENTS WITHIN CEILING SPACE AND AS REQUIRED

BY CODE. LOCATIONS FOR SPECIAL ACCESS DOORS, HATCHES,

ETC. SHALL BE COORDINATED WITH OTHER TRADES.

13. INSPECTIONS, AS REQUIRED BY LOCAL AUTHORITIES, SHALL BE

COORDINATED BY GC PRIOR TO CLOSING OF CEILING.

14. SHOP DRAWINGS FOR ALL RELATED TRADES (PLUMBING, HVAC)

SHALL BE SUBMITTED FOR REVIEW/APPROVAL PRIOR TO

MANUFACTURING AND INSTALLATION.

15. ALL HVAC ELEMENTS SHALL MATCH ADJACENT WALL OR CEILING

FINISH COLOR, INSTALLED FLUSH AND TRUE AND CENTERED

WITHIN THE CEILING GRID. LOCATIONS SHALL BE PER APPROVED

MECHANICAL PLANS.

16. INSULATION OF COLD WATER LINES SHALL BY PROVIDED TO

PREVENT CONDENSATION DAMAGE AND IN OBSERVANCE OF

ENERGY CONSERVATION PRACTICES, HOT WATER HEATING LINES

SHALL BE INSULATED - SEE SPECIFICATIONS.

17. CONTRACTOR SHALL LOCATE THERMOSTATS AND TEMPERATURE

SENSORS IN ACCESSIBLE SPACES AT 4'-0" AND UNITS IN ALL OTHER

SPACES AT 5'-0". UNITS AT 5' SHALL BE MOUNTED ALIGNED

VERTICALLY WITH LIGHT SWITCHES WHERE APPLICABLE.

LOCATIONS PER MECHANICAL PLAN AND TO BE COORDINATED BY

GC WITH OTHER TRADES.

18. ALL BROCHURES, OPERATING MANUALS, CATALOGS, SHOP

DRAWINGS, ETC. SHALL BE TURNED OVER TO THE OWNER AT JOB

COMPLETION. ALL PRODUCT WARRANTY REGISTRATION CARDS,

APPLICATIONS, AND CERTIFICATES SHALL BE COMPLETED AND

TURNED OVER TO THE OWNER.

19. THIS CONTRACTOR SHALL BE REQUIRED TO REPLACE FILTERS ON

HVAC EQUIPMENT AFTER ALL DUST PRODUCING CONSTRUCTION

HAS BEEN COMPLETED AND PRIOR TO THE FINAL PUNCH.

GENERAL MECHANICAL NOTES

V-E/A VENTILATION EXHAUST AIR

D-E/A DRYER EXHAUST AIR

RTU-XX

VAV-XX

TEMPERATURE & HUMIDITY SENSOR

TEMPERATURE SENSOR

THERMOSTAT

SENSOR

MANUAL SWITCH

CARBON DIOXIDE SENSOR

CARBON MONOXIDE SENSOR

NITROGEN DIOXIDE SENSOR

HUMIDITY SENSOR

HUMIDISTAT

CONTROLLER

LOW VOLT TIMER

NATURAL GAS

CONDENSATE DRAINAGECD

NG

* NOTE *

THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET

MAY OR MAY NOT BE USED IN THIS SET OF DRAWINGS.

M-102

LEVEL 1 DISCIPLINE DESIGNATOR

LEVEL 2 DISCIPLINE DESIGNATOR

LEVEL SEQUENCE NUMBER

PLAN TYPE SEQUENCE NUMBER

SHEET TYPE DESIGNATOR

SILETZ, OREGON

ANNUAL DESIGN CONDITIONS: ASHRAE FUNDAMENTALS 2025

WEATHER STATION - NEWPORT SOUTH BEACH JETTY, OR WMO# 994026

ELEVATION: 7' LAT: 44.62N LONG: 124.05W

WINTER: 32.0 (99.6%)

SUMMER: 65.4 DRY BULB (0.4%)

57.9 WET BULB (0.4%)

INDOOR DESIGN CONDITIONS:

WINTER: 70 ± 2º F

SUMMER: 75 ± 2º F

HVAC DESIGN CRITERIA

DUCT INSULATION SCHEDULE

DUCT SYSTEM

SUPPLY AIR

OUTSIDE AIR

FRESH AIR

MIN. R-12 INSULATION & VAPOR

BARRIER. PRE-ENGINEERED

Q-DUCT OR SIMILAR

OUTSIDE BUILDING ENVELOPE,

EXPOSED TO ENVIRONMENT

OUTSIDE BUILDING ENVELOPE,

WITHIN BUILDING

WITHIN THE BUILDING

ENVELOPE

RETURN AIR

RELIEF AIR

TRANSFER AIR

GENERAL EXHAUST AIR

MIN. R-12 INSULATION & VAPOR

BARRIER. PRE-ENGINEERED

Q-DUCT OR SIMILAR

MIN. R-6 INSULATION & VAPOR

BARRIER

MIN. R-6 INSULATION & VAPOR

BARRIER

MIN. R-6 INSULATION & VAPOR

BARRIER WHERE UNCONDITIONED

MIN. R-6 INSULATION WHERE

UNCONDITIONED

GREASE EXHAUST AIR N/A N/A

MIN. R-6 GREASE DUCT FIRE

INSULATION. FYREWRAP ELITE

OR SIMILAR

RETURN AIR

PLENUMS @ GRILLES

N/A

LINE GRILLE PLENUM AND FIRST 6

FT OF DUCT MIN. R-6 INSULATED

LINE GRILLE PLENUM AND FIRST 6

FT OF DUCT MIN. R-6 INSULATED

REMARKS:

1. ALL DUCT DIMENSIONS INDICATE INSIDE FREE DIMENSIONS AND DO NOT INCLUDE INSULATION THICKNESS.

2. THE 6' OF EXHAUST DUCT NEAREST TO THE EXTERIOR TO BE INSULATED WITH MIN. R-6 INSULATION (1 1/2" THICKNESS, 0.24 K VALUE).

2021 INTERNATIONAL ENERGY CONSERVATION CODE NOTES

1. PROVIDE COMMISSIONING PLAN IN ACCORDANCE WITH INTERNATIONAL ENERGY CONSERVATION CODE SECTION C408.2.1.

2. PROVIDE COMMISSIONING COMPLIANCE REPORT IN ACCORDANCE WITH INTERNATIONAL ENERGY CONSERVATION CODE SECTION

C407.3.1 & C407.3.2.

3. PROVIDE SYSTEMS TESTING AND BALANCING IN ACCORDANCE WITH INTERNATIONAL ENERGY CONSERVATION CODE SECTION

C408.2.2.

A. PROVIDE TAB REPORT FOR ALL AIR MOVING EQUIPMENT TO ENGINEER OF RECORD. ALL AIRFLOWS INDICATED ON PLANS ARE

UNDER NORMAL OPERATING CONDITIONS WITH ALL SYSTEMS RUNNING IN OCCUPIED MODE AT MINIMUM OUTSIDE AIR.

4. PROVIDE SYSTEMS, EQUIPMENT, AND CONTROLS FUNCTIONAL TESTING IN ACCORDANCE WITH INTERNATIONAL ENERGY

CONSERVATION CODE SECTION C408.2.3.

5. PROVIDE SUPPORTING DOCUMENTATION IN ACCORDANCE WITH INTERNATIONAL ENERGY CONSERVATION CODE CHAPTER 1

CHECKLIST, INCLUDING OPERATION AND MAINTENANCE MANUALS, HVAC CONTROL SYSTEM MAINTENANCE AND CALIBRATION

INFORMATION, HVAC CONTROL SEQUENCE OF OPERATIONS, COMMISSIONING REPORT, AND RECORD DRAWINGS.

6. PROVIDE OWNER SYSTEMS OPERATION TRAINING IN ACCORDANCE WITH INTERNATIONAL ENERGY CONSERVATION CODE SECTION

C103.6.

7. MOTORS SHALL COMPLY WITH SECTION C403.8 OF THE INTERNATIONAL ENERGY CONSERVATION CODE. FOR ADDITIONAL DETAILS, SEE EQUIPMENT SCHEDULES CONTAINED WITHIN THIS DRAWING SET.

8. SYSTEMS SHALL BE INSULATED AS PRESCRIBED IN SECTION C403.12. FOR ADDITIONAL DETAILS, SEE DUCTWORK AND PIPING

SPECIFICATION MATRICES CONTAINED WITHIN THIS DRAWING SET.

PROJECT GENERAL NOTES

* REMOVE ALL UNUSED PIPING, DUCTWORK AND ACCESSORIES.

* THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR

FIELD VERIFYING, PRIOR TO FINAL BID, ALL EXISTING

CONDITIONS FOR PLUMBING AND MECHANICAL SYSTEMS

WITHIN TENANT SPACE AND WITHIN CLOSE PROXIMITY OF

TENANT SPACE.

* WHERE FLOOR DRAINS OCCUR WITHIN THE LIMITS OF

CONSTRUCTION, PREVENT CONSTRUCTION DEBRIS FROM

ENTERING DRAIN BODY BY SEALING DRAIN OPENING PRIOR TO

START OF WORK. UNSEAL DRAINS AT COMPLETION OF

CONSTRUCTION.

* COORDINATE INSTALLATION OF PIPING, DUCTWORK, CONDUIT,

LIGHTS, CABLE TRAY, STRUCTURE, AND EQUIPMENT TO

PREVENT CONFLICTS.

* THE CONTRACTOR SHALL BE FAMILIAR WITH ALL THE

CONDITIONS BOTH EXISTING AND THOSE ILLUSTRATED BY

THESE DOCUMENTS AS WELL AS THOSE WHICH CAN BE

REASONABLY ANTICIPATED INCLUDING, BUT NOT LIMITED TO

ARCHITECTURAL, ELECTRICAL, VENTILATION, PLUMBING, AND

OTHER SYSTEMS INVOLVED ON THIS PROJECT.

* FINAL PRODUCT SHALL BE A COMPLETE AND FUNCTIONING

SYSTEM, AND SHALL CONFORM TO ALL REQUIREMENTS OF

APPLICABLE FEDERAL, STATE, AND LOCAL CODES, INCLUDING

BUT NOT LIMITED TO THE INTERNATIONAL BUILDING CODE

AND INTERNATIONAL MECHANICAL CODE.

* ALL ROOF MOUNTED EQUIPMENT SHALL BE A MINIMUM 10'-0"

FROM EDGE OF ROOF.

* LOCATE DUCTWORK, PIPING AND MECHANICAL EQUIPMENT

AWAY FROM THE SPACE ABOVE ELECTRICAL PANELS.

TRANSFORMERS AND OTHER ELECTRICAL EQUIPMENT.

* FIRE SEAL AROUND DUCT AND PIPING PENETRATIONS OF FIRE

RATED WALLS. REFER TO SPECIFICATION.

* PROVIDE SLEEVES AND/OR OPENINGS TO RUN PIPES AND

DUCTS THROUGH FOUNDATIONS, FLOORS, WALLS, AND ROOF.

* ADJUST PIPING AND DUCTWORK SIZES TO PROPERLY CONNECT

TO MECHANICAL EQUIPMENT.

* REFER TO PLUMBING SERIES DRAWINGS FOR GAS AND A.C.

CONDENSATE DRAIN PIPING.

* PIPE SIZES SHOWN SHALL BE CONTINUED IN THE DIRECTION OF

FLOW UNTIL ANOTHER SIZE IS SHOWN.

* FOR DETAILS, EQUIPMENT CONNECTIONS, AND PIPE SIZES NOT

SHOWN ON THE SEGMENTS, REFER TO DETAILS, SCHEDULES,

AND SPECIFICATIONS.

* INSTALL ALL EQUIPMENT IN ACCORDANCE WITH THE

RESPECTIVE MANUFACTURER'S WRITTEN INSTALLATION

INSTRUCTIONS, AT A LEVEL OF QUALITY AND WORKMANSHIP

CONSISTENT WITH THE SPECIFICATIONS.

* LOCATIONS OF PIPING, DUCTWORK AND EQUIPMENT AS

INDICATED ON THE DRAWING, ARE APPROXIMATE AND

SUBJECT TO MINOR ADJUSTMENTS IN THE FIELD. WORK SHALL

BE COORDINATED WITH ALL OTHER TRADES TO AVOID

INTERFERENCE IN THE FIELD.

* INSTALL EXPOSED PIPING AND DUCTWORK AS HIGH AS

PRACTICAL IN ROOMS WITHOUT CEILINGS U.N.O.

MECHANICAL SHEET INDEX

M-001 MECHANICAL TITLE SHEET

M-111 LEVEL 1 HVAC PLAN

M-141 ROOF HVAC PLAN

M-601 MECHANICAL SCHEDULES & DETAILS

DATE:

JACKOLA ENGR. & ARCH., P.C.

WITHOUT THE WRITTEN CONSENT OF

MAY NOT BE USED OR REPRODUCED

IS PROPRIETARY. THIS DOCUMENT

THE INFORMATION CONTAINED HEREIN

REVISIONS:

FOR CONSTRUCTION

KALISPELL

406-755-3208

BOZEMAN

406-586-0707

VANCOUVER

360-852-8746

DRAWN: CHECKED:

info@jackola.com jackola.com

M-001

03/17/2026

B R

O A

D B

A N

D R

E M

O D

E L

C O

N F

E D

E R

A T

E D

T R

IB

E

S O

F T

H E

S

IL

E T

Z I N

D

IA

N S

S E

S W

A N

A V

E

S

IL

E T

Z

O R

MECHANICAL

TITLE SHEET

BBEW

P R

O J E

C T

:2

HVAC GENERAL NOTES

* CONTRACTOR SHALL LOCATE THERMOSTATS AND

TEMPERATURE SENSORS AT 4'-0" AFF, A MAXIMUM OF 8"

FROM LIGHT SWITCH.

* PROVIDE A 4" HOUSEKEEPING PAD FOR EACH PIECE OF

MECHANICAL EQUIPMENT. COORDINATE SIZES WITH

MECHANICAL EQUIPMENT SELECTED.

* ALL SUPPLY, RETURN, AND EXHAUST DUCTWORK SHALL BE

RATED FOR PRESSURE CLASS OF 2" W.G. UNLESS NOTED

OTHERWISE.

* THIS CONTRACTOR SHALL BE REQUIRED TO REPLACE FILTERS

ON HVAC EQUIPMENT AFTER ALL DUST PRODUCING

CONSTRUCTION HAS BEEN COMPLETED AND PRIOR TO THE

FINAL PUNCH.

ENG INEER

R E

G

IS

TERE D P R O F E SS

I O

N A

L

OREGON

102276PE

EXPIRES: 12/31/2025

M A R. 1 4 , 2 0 2 3

B

AL

A

K

E

JO S E P H BA RT U

S I

2 2

3 3

4 4

A

A

B

B

C

C

D

D

1 1

WM-1

WM-2

R.R.

FOYER

R.R.

CLOSET

CLOSET

PANTRY

OFFICE

HALL

300A

CONFERENCE

MECH

307A

IT ROOM

OFFICE

KEYNOTES

1 PROVIDE FEHOM 150 PINT DEHUMIDIFIER WITH CONDENSATE

PUMP OR OWNER APPROVED ALTERNATE.

2 1KW ELECTRIC WALL HEATER BY ELECTRICAL CONTRACTOR.

3 ONE THERMOSTAT SETPOINT TO BE 5°F HIGHER TO ACT AS

BACKUP.

0 4' 8'2' 1/4" = 1'-0"1

LEVEL 1 HVAC PLAN

DATE:

JACKOLA ENGR. & ARCH., P.C.

WITHOUT THE WRITTEN CONSENT OF

MAY NOT BE USED OR REPRODUCED

IS PROPRIETARY. THIS DOCUMENT

THE INFORMATION CONTAINED HEREIN

REVISIONS:

FOR CONSTRUCTION

KALISPELL

406-755-3208

BOZEMAN

406-586-0707

VANCOUVER

360-852-8746

DRAWN: CHECKED:

info@jackola.com jackola.com

M-111

03/17/2026

B R

O A

D B

A N

D R

E M

O D

E L

C O

N F

E D

E R

A T

E D

T R

IB

E

S O

F T

H E

S

IL

E T

Z I N

D

IA

N S

S E

S W

A N

A V

E

S

IL

E T

Z

O R

LEVEL 1 HVAC

PLAN

BBEW

P R

O J E

C T

:2

ENG INEER

R E

G

IS

TERE D P R O F E SS

I O

N A

L

OREGON

102276PE

EXPIRES: 12/31/2025

M A R. 1 4 , 2 0 2 3

B

AL

A

K

E

JO S E P H BA RT U

S I

3 3

4 4

A

A

B

B

C

C

D

D

1 1

HP-1

HP-2

(E)CU

(E)CU

KEYNOTES

1 MOUNT HEAT PUMPS ON ROOF PER DETAIL 1 ON SHEET M-601.

0 4' 8'2' 1/4" = 1'-0"1

ROOF HVAC PLAN

DATE:

JACKOLA ENGR. & ARCH., P.C.

WITHOUT THE WRITTEN CONSENT OF

MAY NOT BE USED OR REPRODUCED

IS PROPRIETARY. THIS DOCUMENT

THE INFORMATION CONTAINED HEREIN

REVISIONS:

FOR CONSTRUCTION

KALISPELL

406-755-3208

BOZEMAN

406-586-0707

VANCOUVER

360-852-8746

DRAWN: CHECKED:

info@jackola.com jackola.com

M-141

03/17/2026

B R

O A

D B

A N

D R

E M

O D

E L

C O

N F

E D

E R

A T

E D

T R

IB

E

S O

F T

H E

S

IL

E T

Z I N

D

IA

N S

S E

S W

A N

A V

E

S

IL

E T

Z

O R

ROOF HVAC

PLAN

BBEW

P R

O J E

C T

:2

ENG INEER

R E

G

IS

TERE D P R O F E SS

I O

N A

L

OREGON

102276PE

EXPIRES: 12/31/2025

M A R. 1 4 , 2 0 2 3

B

AL

A

K

E

JO S E P H BA RT U

S

PRE MOULDED

RUBBER ROOF JACK,

UV RESISTANT TYP.

(4)

(4) 1/4"x3-1/2"L

SIMPSON SDS

SCREWS.

WELD BOOT TO

TPO.

SEAL ALL

JOINTS

SIZE FRAME PER

MANUFACTURERS

RECCOMENDATIONS FOR UNIT

SIZE AND QUANTITY. BASIS OF

DESIGN: DIVERSITECH

QSMS1801

MECHANIC

AL UNIT

BOLT UNIT TO

STAND. WITH

1/4"Ø STAINLESS

STEEL 300 SERIES

BOLTS, AND RESIN

WASHER TO

PREVENT PAINT

SCRATCHING AND

RUSTING

ANTI VIBRATION

PAD

DATE:

JACKOLA ENGR. & ARCH., P.C.

WITHOUT THE WRITTEN CONSENT OF

MAY NOT BE USED OR REPRODUCED

IS PROPRIETARY. THIS DOCUMENT

THE INFORMATION CONTAINED HEREIN

REVISIONS:

FOR CONSTRUCTION

KALISPELL

406-755-3208

BOZEMAN

406-586-0707

VANCOUVER

360-852-8746

DRAWN: CHECKED:

info@jackola.com jackola.com

M-601

03/17/2026

B R

O A

D B

A N

D R

E M

O D

E L

C O

N F

E D

E R

A T

E D

T R

IB

E

S O

F T

H E

S

IL

E T

Z I N

D

IA

N S

S E

S W

A N

A V

E

S

IL

E T

Z

O R

MECHANICAL

SCHEDULES &

DETAILS

BBEW

P R

O J E

C T

:2

MINI-SPLIT HEAT PUMP SCHEDULE

TAG DESCRIPTION

BASIS OF DESIGN SYSTEM INTERLOCK

QTY

COOLING COMPRESSOR RATED OPERATING RANGE

EER SEER HSPF COP

UNIT

WEIGHT

ELECTRICAL DATA

REMARKSMANUFACTURER MODEL NO. INDOOR UNIT NOMINAL CAP

REFRIGERANT MOTOR

HEATING

COOLING

FLA MCA MOCP VOLT PHTYPE CHARGE RLA MIN MAX

HP-1 OUTDOOR UNIT SAMSUNG AR12DXFAMWKXCV WM-1 1 12,000 Btu/h R-32 25 lb 9 A -5.0 °F 14.0 °F 115 °F 13.5 24 9 1.76 71 lb 10 A 12 A 20 A 230 V 1

HP-2 OUTDOOR UNIT SAMSUNG AR12DXFAMWKXCV WM-2 1 12,000 Btu/h R-32 25 lb 9 A -5.0 °F 14.0 °F 115 °F 13.5 24 9 1.76 71 lb 10 A 12 A 20 A 230 V 1

MINI-SPLIT DUCTLESS FAN COIL SCHEDULE

TAG DESCRIPTION

BASIS OF DESIGN SYSTEM INTERLOCK

SUPPLY

AIRFLOW

FAN

EVAPORATOR

COOLING COIL

CONDENSER

HEATING COIL ACCESSORIES

UNIT

WEIGHT REMARKSMANUFACTURER MODEL NO. HEAT PUMP

MOTOR

NOMINAL CAP NOMINAL CAP

POWERED BY

OUTDOOR

UNITQTY POWER

WM-1 INDOOR UNIT SAMSUNG AR12DXFAMWKNCV HP-1 375 CFM 1 27 W 12,000 Btu/h 12,000 Btu/h Yes 23 lb

WM-2 INDOOR UNIT SAMSUNG AR12DXFAMWKNCV HP-2 375 CFM 1 27 W 12,000 Btu/h 12,000 Btu/h Yes 23 lb

REMARKS:

1. ALL UNITS TO BE SUPPLIED WITH STANDS.

NTS1

HVAC UNIT STAND DETAIL

ENG INEER

R E

G

IS

TERE D P R O F E SS

I O

N A

L

OREGON

102276PE

EXPIRES: 12/31/2025

M A R. 1 4 , 2 0 2 3

B

AL

A

K

E

JO S E P H BA RT U

S

WV

CA

CD

CW

F-CW

H-CW

S-CW

HW

HW 140°

HWC

HWC 140°

GV

GW

NG

OV

OW

V

W

RW

RWO

COMBINATION WASTE& VENT

COMPRESSED AIR

CONDENSATE DRAINAGE

COLD WATER

FILTERED COLD WATER

HARD COLD WATER

SOFT COLD WATER

HOT WATER

HOT WATER 140°

HOT WATER RECIRC

HOT WATER RECIRC 140°

GREASE VENT

GREASE WASTE

NATURAL GAS

SAND/OIL VENT

SAND/OIL WASTE

SANITARY VENT

SANITARY SEWER

RAIN WATER

RAIN WATER OVERFLOW

CAP

PLUG

2"

4"

4" 4"

PLUMBING AND PIPING SYMBOLS

KEYNOTE CONTINUATION SYMBOL

NUMBER OF SHEET WHERE DETAIL APPEARS

NUMBER OF DETAIL ON SHEET

REVISION NUMBER - SHOWN ON PLANS

GENERAL PLUMBING SYMBOLS

ROOM NAME AND NUMBER

POINT WHERE NEW CONNECTS TO EXISTING

ITEM TO BE DEMOLISHED

AREA NOT IN CONTRACT

DRAIN SIZE

PIPE RISE

PIPE DROP

PIPE TEE

REDUCING 45

DEGREE TEE

45 DEGREE TEE

* NOTE *

THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET

MAY OR MAY NOT BE USED IN THIS SET OF DRAWINGS.

LP PROPANE GAS

TYPE (SEE SCHEDULE)

Room

RO REVERSE OSMOSIS WATER

IW INDIRECT WASTE

4000 SF

6" RD-1

Ø ROUND

ABV ABOVE

AC AIR CONDITIONING

AD AREA DRAIN

ADD ADDENDUM

AFF ABOVE FINISHED FLOOR

AFUE ANNUAL FUEL UTILIZATION EFFICIENCY

ALT ALTERNATE

AP ACCESS PANEL

ARCH ARCHITECT/ARCHITECTURAL

BFF BELOW FINISHED FLOOR

BLW BELOW

BTU BRITISH THERMAL UNITS

BTUH BRITISH THERMAL UNITS PER HOUR

CAP CAPACITY

CB CATCH BASIN

CFM CUBIC FEET PER MINUTE

CLG CEILING

CO CLEAN OUT

CW COLD WATER

D DEGREE

DB DRY BULB

DIA DIAMETER

DN DOWN

DW DISTILLED WATER

EA EACH

EAT ENTERING AIR TEMPERATURE

ELEC ELECTRICAL

EQUIP EQUIPMENT

EWC ELECTRIC WATER COOLER

EWT ENTERING WATER TEMPERATURE

E/A EXHAUST AIR

EXIST EXISTING

F DEGREES FAHRENHEIT

FCO FLOOR CLEAN OUT

FD FLOOR DRAIN

FD FIRE DAMPER

FDV FIRE DEPARTMENT VALVE

FL FLOOR

FO FUEL OIL

FOV FUEL OIL VENT

FOR FUEL OIL RETURN

FOS FUEL OIL SUPPLY

FPM FEET PER MINUTE

FS FLOOR SINK

FT FOOT/FEET

FTR FIN TUBE RADIATION

GAL GALLON

GC GENERAL CONTRACTOR

GPM GALLONS PER MINUTE

GW GREASE WASTE

HB HOSE BIB

HP HORSE POWER

HTG HEATING

HTR HEATER

HW HOT WATER

HYD HYDRANT

ID INDIRECT

IN INCH

INV INVERT

LB POUND

LB/HR POUNDS PER HOUR

LAT LEAVING AIR TEMPERATURE

LP LOW PRESSURE

LPG LIQUEFIED PETROLEUM GAS

LVR LOUVER

LWT LEAVING WATER TEMPERATURE

M/A MIXED AIR

MAX MAXIMUM

MBH ONE THOUSAND BTU PER HOUR

MCF ONE THOUSAND CUBIC FEET

MD MOTORIZED DAMPER

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MTR MOTOR

MU/A MAKE-UP/AIR

NC NOISE CRITERIA

NC NORMALLY CLOSED

NIC NOT IN CONTRACT

NO NUMBER

NO NORMALLY OPEN

NTS NOT TO SCALE

O OXYGEN

O/A OUTSIDE AIR

PD PRESSURE DROP

PIV POST INDICATOR VALVE

ABBREVIATIONS

4" FD-1FLOOR DRAIN

4" FS-2FLOOR SINK

4" FD-3PFLOOR DRAIN

8 WFU

4" FD-13

HUB DRAIN

DRAIN TAGS

"P" - INDICATES PRIMER

CONNECTION

FIXTURE UNITS

COMBINATION

DRAINS

ROOF AREA SERVED

BY DRAIN

2" DOM. WM

PIPE ACCESSORY TAGS

DOMESTIC WATER METER

BALANCING VALVE

1/4 TURN BALL VALVE

CHECK VALVE

3-WAY MIXING VALVE

MOTORIZED CONTROL VALVE

3 WAY MOTORIZED CONTROL

VALVE

PRESSURE REDUCING VALVE

REFRIGERANT SOLENOID VALVE

BUTTERFLY VALVE

2" BALANCING

2" SHUTOFF

2" CHECK

2" TMV

2" M-CNTRL

2" 3-WAY CNTRL

2" PRV

3/8" SOLENOID

2" BUTTERFLY

WATER CLOSET -

WALL HUNG - ADA WC-5

UR-2

1 WFU

LAV-1A

LAV-1A

4" WCO

PIPE ACCESORY

TAG

PLUMBING FIXTURE TAGS

4" WCO

TYPE (SEE SCHEDULE)

WC-5A

PIPING SYMBOLSGENERAL PLUMBING NOTES

1. ALL PLUMBING AND PRACTICE TO BE IN ACCORDANCE WITH

CURRENT UNIFORM PLUMBING CODE.

2. COMPLETE INSTALLATION OF PLUMBING SYSTEM TO

CONFORM TO STATE BUILDING, MECHANICAL ENERGY, FIRE,

AND HEALTH CODES, AND REGULATIONS ADOPTED BY LOCAL

JURISDICTIONS.

3. PLUMBING SYSTEMS AS SHOWN ARE SCHEMATIC IN NATURE

AND ITEMS NOT SPECIFICALLY CALLED FOR OR SHOWN, BUT

REQUIRED FOR INSTALLATION FOR THE COMPLETE MECH.

SHALL BE PROVIDED, AND ARE REQUIRED AS PART OF THE

CONTRACT. MANUFACTURER'S RECOMMENDATIONS AND

INDUSTRY STANDARDS SHALL APPLY.

4. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL

LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE

PLUMBING SYSTEMS AS INDICATED ON THE DRAWINGS, AS

SPECIFIED, AND AS REQUIRED BY CODE.

5. CONTRACTOR RESPONSIBILITY TO VERIFY QUANTITIES.

6. MAINTAIN A MINIMUM OF 6'-6" OF GROUND COVER OVER ALL

UNDERGROUND WATER MAINS AND A MINIMUM OF 3'0" OF

GROUND COVER OVER ALL UNDERGROUND SEWERS AND

DRAINS.

7. INSTALL ALL PIPING WITHOUT FORCING OR SPRINGING.

8. ALL PIPING SHALL CLEAR DOORS AND WINDOWS.

9. ALL PIPING SHALL GRADE TO LOW POINTS. PROVIDE HOSE END

DRAIN VALVES AT THE BOTTOM OF ALL RISERS AND LOW

POINTS.

10. SUBCONTRACTOR SHALL COORDINATE WITH GENERAL AND

VERIFY ALL ROUTING AND SUPPORT SYSTEMS & INCLUDE IN HIS

BID ALL NECESSARY TO PROVIDE THE OWNER WITH A

COMPLETE SYSTEM.

11. ALL PIPING WORK SHALL BE COORDINATED WITH ALL TRADES

INVOLVED. OFFSETS IN PIPING AROUND OBSTRUCTIONS SHALL

BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER.

12. ALL "OR EQUAL" FIXTURES AND ACCESSORIES TO BE APPROVED

BY ARCHITECT OR ENGINEER.

13. UNLESS SPECIFICALLY NOTED OTHERWISE, ALL FIXTURES SHALL

BE WHITE.

14. IT IS UNLAWFUL TO CONCEAL CRACKS, HOLES, OR OTHER

IMPERFECTIONS IN MATERIALS BY WELDING, BRAZING, OR

SOLDERING OR BY USING THEREIN OR THEREON ANY PAINT,

WAX, TAR, OR OTHER LEAK-SEALING OR REPAIR AGENT.

15. BURRED ENDS OF ALL PIPE AND TUBING SHALL BE REAMED TO

THE FULL BORE OF THE PIPE.

16. PLUMBING SYSTEMS SHALL BE INSTALLED IN A MANNER

CONFORMING TO THE PLUMBING CODE AND THE

MANUFACTURER'S RECOMMENDATIONS. IN INSTANCES

WHERE THE CODE AND THE MANUFACTURER'S INSTRUCTIONS

CONFLICT, THE MORE STRINGENT PROVISIONS SHALL PREVAIL.

17. ALL VALVES, PIPES, AND FITTINGS SHALL BE INSTALLED IN

CORRECT RELATIONSHIP TO THE DIRECTION OF FLOW.

18. NO PIPING SHALL BE DIRECTLY EMBEDDED IN CONCRETE OR

MASONRY. NO STRUCTURAL MEMBER SHALL BE SERIOUSLY

WEAKENED OR IMPAIRED BY CUTTING, NOTCHING OR

OTHERWISE.

19. PIPING SUBJECT TO UNDUE CORROSION, EROSION, OR

MECHANICAL DAMAGE SHALL BE PROTECTED IN AN APPROVED

MANNER.

20. NO WATER, SOIL, OR WASTE PIPE SHALL BE INSTALLED OR

PERMITTED OUTSIDE A BUILDING OR IN AN EXTERIOR WALL

UNLESS, WHERE NECESSARY, ADEQUATE PROVISION IS MADE

TO PROTECT SUCH PIPE FROM FREEZING.

21. ALL PIPE PENETRATING FLOOR/CEILING ASSEMBLIES AND FIRE-

RESISTANCE RATED WALLS OR PARTITIONS SHALL BE

PROTECTED WITH THE REQUIREMENTS OF THE BUILDING

CODE.

22. SLEEVES SHALL BE PROVIDED TO PROTECT ALL PIPING

THROUGH CONCRETE OR MASONRY EXTERIOR OR BEARING

WALLS, AND SHALL BE SIZED SO THERE IS A MINIMUM 1/2"

CLEARANCE AROUND THE PIPE AND/OR INSULATION.

23. PIPING THROUGH CONCRETE OR MASONRY WALLS SHALL NOT

BE SUBJECT TO ANY LOAD FROM BUILDING CONSTRUCTION.

24. ALL PIPING SHALL BE SUPPORTED IN SUCH A MANNER AS TO

MAINTAIN ITS ALIGNMENT, AND PREVENT SAGGING.

25. ALL PIPING SHALL BE HUNG AND/OR SUPPORTED TO

ELIMINATE NOISE AND VIBRATION WITH APPROPRIATE

HANGERS AND SUPPORTS. SEE DETAILS FOR REQUIREMENTS.

26. PIPING IN THE GROUND SHALL BE LAID ON A FIRM BED FOR ITS

ENTIRE LENGTH. WHERE SUPPORT IS OTHERWISE PROVIDED, IT

SHALL BE ACCEPTABLE TO THE ADMINISTRATIVE AUTHORITY.

27. HANGERS AND ANCHORS SHALL BE OF SUFFICIENT STRENGTH

TO SUPPORT THE WEIGHT OF THE PIPE AND ITS CONTENTS.

PIPING SHALL BE ISOLATED FROM INCOMPATIBLE MATERIALS.

28. THREADS ON IRON PIPE SIZE (IPS) PIPE AND FITTINGS SHALL BE

STANDARD TAPER PIPE THREADS. THREADS ON TUBING SHALL

BE APPROVED TYPES. THREADS ON PLASTIC PIPE SHALL BE

FACTORY CUT OR MOLDED. THREADED PLASTIC PIPE SHALL BE

SCHEDULE 80 MINIMUM WALL THICKNESS. TUBING THREADS

SHALL CONFORM TO FINE TUBING THREAD STANDARDS. WHEN

A PIPE JOINT MATERIAL IS USED, IT SHALL BE APPLIED ONLY ON

MALE THREADS AND SUCH MATERIALS SHALL BE APPROVED

TYPES, INSOLUBLE IN WATER, AND NONTOXIC. CLEANOUT

PLUGS AND CAPS SHALL BE LUBRICATED WITH…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .