2025-08_Tigerville_FD_3-17-2026.pdf
PDF 5 MB Posted
- Attached to
- Fire Sprinkler System
- Solicitation number
- RFP #27006
- Issued by
- Greenville County, South Carolina
About this file
This is an architectural drawing set and building code analysis document prepared by Robert C. Cashion, Architect, Inc. for the County of Greenville on behalf of the Tigerville Fire Department, located at 2605 SC-414, Travelers Rest, South Carolina. The project scope includes the design and installation of a new automatic fire sprinkler system throughout the 13,910 square-foot, two-story Type V-B mixed occupancy firehouse, along with renovations to the second floor. The existing building contains offices, a day room, break room, training room, sleeping quarters, restrooms, storage areas, and fire truck bays. The project maintains the existing occupant load of 93 persons and requires the building to comply with all applicable provisions of the 2021 South Carolina Building Code, including specific interior finish ratings, corridor widths, exit capacities, and accessibility standards. The second floor renovation includes reconfiguration of bunk rooms, toilets, and support spaces, while the first floor receives only the sprinkler system installation with no other renovations. The architectural drawings indicate new interior wall framing, door schedules, reflected ceiling plans, and finishes specifications for all affected spaces.
The drawings establish specific code compliance requirements including Class B interior finish for corridors and exit access enclosures, Class C interior finish for other enclosed spaces, automatic sprinkler system installation per South Carolina Building Code Section 903.2.8, and fire-rated drywall construction for sleeping room areas and their adjacent corridors. The project requires portable fire extinguishers, access doors to concealed spaces, proper floor covering materials meeting DOC FF-1 standards, and smoke detection systems in sleeping areas. Ceiling construction in sleeping rooms and adjacent areas must include two layers of 5/8-inch Type-X gypsum wallboard, with one-hour fire-rated walls and ceilings throughout the protected egress paths. All new interior doors are specified as 20-minute rated solid core wood doors. The document indicates sealed proposals are being sought from qualified fire sprinkler contractors for design, permitting, installation, testing, and acceptance of the automatic fire sprinkler system, with the drawing dated January 6, 2026.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Fire_Sprinkler_System.pdf | ||
| TFD_FSSSS_4-29-26.pdf | ||
| COG_Sub_W9_.pdf | ||
| Sample_Services_Agreement.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
8' -0
8'
-0
20'-0"
5' -0
31'-8"
AN AUTOMATIC SPRINKLER SYSTEM IS REQUIRED (SCBC SECTION 903.2.8)
A CLASS III STANDPIPE SYSTEM IS NOT REQUIRED (SCBC SECTION 905)
MAXIMUM TRAVEL DISTANCE ALLOWED TO AN EXIT = 300 FEET FOR SPRINKLERED SPACES
(SCBC TABLE 1017.2)
REQUIRED EXIT WIDTH BASED ON OCCUPANT LOAD OF 93=93 x .15=13.95 INCHES (SCBC 1005.3.2)
EXIT WIDTH PROVIDED FROM BUILDING = 141 INCHES
TOTAL EXIT CAPACITY - 3 EXITS x 233 EA. = 940
ACTUAL FARTHEST TRAVEL DISTANCE PROVIDED TO AN EXIT = 80 FEET
PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN THE STRUCTURE WHILE UNDER RENOVATION IN ACCORDANCE WITH F1414.1 & WHERE REQUIRED BY THE SECTIONS INDICATED IN TABLE F906.1.
INTERIOR FLOOR FINISH & FLOOR COVERING MATERIALS SHALL BE IDENTIFIED BY A HANG TAG OR OTHER SUITABLE METHOD AS TO IDENTIFY MANUFACTURER OR SUPPLIER & STYLE. CARPET-TYPE
FLOOR COVERINGS SHALL BE TESTED AS PROPOSED FOR USE. (SCBC 804.3)
PROVIDE CODE APPROVED ACCESS DOORS TO ALL CONCEALED SPACES (FIRE RATED WHERE REQ'D).
THE PERMANENT INSTALLATION OF PORTABLE FIRE EXTINGUISHERS IS REQUIRED IN GROUPS B, R-2, & S OCCUPANCIES (SCBC SECTION F906.1).
THE WIDTH OF THE MAIN ENTRANCE DOOR IS SUFFICIENT TO ACCOMMODATE A MINIMUM OF
50 PERCENT OF THE TOTAL OCCUPANT LOAD IN ACCORDANCE WITH SCBC SECTION 1005.5.
INTERIOR FLOOR FINISH MATERIALS USED ON FLOORS OF EXIT ENCLOSURES, EXIT PASSAGEWAYS, & CORRIDORS SHALL NOT BE LESS THAN CLASS II. IN ALL AREAS, FLOOR COVERING MATERIALS SHALL COMPLY WITH THE DOC FF-1 "PILL TEST" (CPSC 16 CFR, PART 1630). (SCBC 804.4.1)
MINIMUM CORRIDOR WIDTH ALLOWED = 44 INCHES (SCBC TABLE 1020.3)
MINIMUM CORRIDOR WIDTH PROVIDED = 48 INCHES
PROJECT SCOPE:
THIS PROJECT INCLUDES THE INSTALLATION
OF A FIRE SPRINKLER SYSTEM THROUGHOUT
THE BUILDING AND RENOVATIONS TO THE
SECOND FLOOR. THE EXISTING 2-STORY,
13,910 SQ. FT., TYPE V-B MIXED OCCUPANCY
FIREHOUSE CONTAINS OFFICES, DAY ROOM,
BREAK ROOM, TRAINING ROOM, SLEEPING
QUARTERS, RESTROOMS, STORAGE, & FIRE
TRUCK BAYS. NO SITE IMPROVEMENTS ARE
TO BE MADE.
BUILDING CODE ANALYSIS
METHOD OF CALCULATING OCCUPANT LOAD AS PER SCBC TABLE 1004.5:
OWNER SHALL MAKE PROVISIONS FOR SPECIAL TESTS & INSPECTIONS IN COMPLIANCE WITH APPLICABLE
PROVISIONS OF SCBC CHAPTER 17.
INTERIOR FINISH, DECORATIVE MATERIALS, & FURNISHINGS TO COMPLY WITH CHAPTER 8 OF IFC.
GENERAL
REFERENCED
CODES
MINIMUM
PLUMBING
FIXTURES
ACCESSIBILITY
SPECIAL TESTS
& INSPECTIONS
ROOMS AND ENCLOSED SPACES SHALL HAVE NOT LESS THAN CLASS C INTERIOR FINISH, FLAMESPREAD
76-200, SMOKE DEVELOPED 0-450. (SCBC 803.1 & TABLE 803.5)
THE ANNULAR SPACE AROUND PIPES, TUBES, CONDUIT, WIRES, CABLES AND VENTS SHALL BE PROTECTED IN
ACCORDANCE WITH THE BUILDING CODE - SEE SCBC 714
EXIT ACCESS ENCLOSURES & PASSAGEWAYS SHALL HAVE CLASS B INTERIOR FINISH. FLAMESPREAD 26-75, SMOKE DEVELOPED 0-450. CORRIDORS SHALL HAVE CLASS B INTERIOR FINISH. FLAMESPREAD 26-75, SMOKE DEVELOPED 0-450. (SCBC 803.1 AND TABLE 803.5) ROOMS & ENCLOSED SPACES SHALL HAVE NOT LESS THAN CLASS C INTERIOR FINISH. FLAMESPREAD 76-200, SMOKE DEVELOPED 0-450. (SCBC 803.1 & TABLE 803.5)
ALL DECORATIVE MATERIALS SUCH AS DRAPERIES AND CURTAINS MUST BE NONCOMBUSTIBLE, INHERENTLY FLAME RESISTANT OR TREATED AND MAINTAINED FLAME RESISTANT WHEN TESTED IN ACCORDANCE WITH
NFPA 701. (STANDARD FIRE PREVENTION CODE 4102.1.1)
2 INDEPENDENT AND SEPARATE EXITS ARE REQUIRED (SCBC TABLE 1006.3.3)
5 INDEPENDENT AND SEPARATE EXITS ARE PROVIDED.
OCCUPANT LOAD = 93 PERSONS
CONSTRUCTION COMPLIES WITH ALL APPLICABLE PROVISIONS OF SCBC CHAPTER 11.
CALCULATION OF MINIMUM FIXTURES FOR BUSINESS GROUP B FROM SOUTH CAROLINA BUILDING CODE
TABLE 2902.1 & SCBC SECTION 1109.5.1
REQUIRED SERVICE SINKS = 1 (1 IS PROVIDED)
REQUIRED DRINKING FOUNTAINS = 2 PER SCBC 1109.5.1 (2 ARE PROVIDED)
REQUIRED LAVATORIES = 3 (4 LAVATORIES ARE PROVIDED)
REQUIRED WATER CLOSETS = 2 (3 WATER CLOSETS ARE PROVIDED)
ALLOWABLE AREA FACTOR IN SQUARE FEET (SCBC TABLE 506.2)
ALLOWABLE AREA INCREASE IN SQUARE FEET FOR FRONTAGE (SCBC 506.3)
TOTAL ALLOWABLE AREA N SQUARE FEET WITH AREA INCREASE
ACTUAL GROSS AREA OF BUILDING IN SQUARE FEET
PROVIDE CODE APPROVED ACCESS DOORS TO ALL CONCEALED SPACES (FIRE RATED WHERE REQUIRED).
ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE (SCBC TABLE 504.3)
ACTUAL BUILDING HEIGHT IN FEET ABOVE GRADE PLANE
ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE (SCBC TABLE 504.4)
ACTUAL NUMBER OF STORIES ABOVE GRADE PLANE
TYPE V-B, UNPROTECTED, SPRINKLERED (SCBC 602.5)
MEANS OF
EGRESS
REQUIREMENTS
OCCUPANCY
CLASSIFICATION
TOTAL OCCUPANT LOAD OF BUILDING = 93
OCCUPANT LOAD FOR PURPOSE OF CALCULATING EXIT CAPACITY = 93
OCCUPANT LOAD FOR PURPOSE OF CALCULATING PLUMBING FIXTURES = 93
22,000 16,500 38,500
13,910ACTUAL AREA
ALLOWABLE
AREA
ALLOWABLE NO.
OF STORIES
ALLOWABLE
BUILDING HT.
CONSTRUCTION
GROSS AREA OF BUILDING = 13,910 SQ. FT.
EVERY 150 SQ. FT. OF GROSS AREA = 1 OCCUPANT
9,730 SQ. FT. ON FIRST FLOOR = 65 FIRST FLOOR OCCUPANTS
MIXED OCUPANCY, NON-SEPARATED GROUPS B, R-2, S-1, & U SPRINKLERED THROUGHOUT INCLUDING BUSINESS GROUP B (SCBC 304.1) (THE USE OF A BUILDING OR STRUCTURE OR A PORTION THEREOF, FOR OFFICE, PROFESSIONAL OR SERVICE-TYPE TRANSACTIONS), SLEEPING QUARTERS, MODERATE HAZARD STORAGE, GROUP S-1 (SCBC 311.2), & UTILITY USES COMPLYING WITH THE MAXIMUM ALLOWABLE
QUANTITIES OF HAZARDOUS MATERIALS LISTED IN TABLE 307.1(1)
IT SHALL BE THE GENERAL CONTRACTOR'S AND OWNER'S RESPONSIBILITY TO COMPLY WITH
APPLICABLE PROVISIONS OF THE SOUTH CAROLINA CODES AND THE REQUIREMENTS LISTED BELOW.
SOUTH CAROLINA BUILDING CODE (SCBC) 2021
NATIONAL ELECTRICAL CODE, NFPA 70 (NEC) 2020
SOUTH CAROLINA ENERGY CONSERVATION CODE WITH ASHRAE / IES 90.1-2009
SOUTH CAROLINA EXISTING BUILDING CODE (IEBC) 2021
SOUTH CAROLINA FIRE CODE (SCFC) 2021
SOUTH CAROLINA FUEL GAS CODE (SCFGC) 2021
SOUTH CAROLINA MECHANICAL CODE (SCMC) 2021
SOUTH CAROLINA PLUMBING CODE (SCPC) 2021
ICC A117.1 STANDARD FOR ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 2017 EDITION SOUTH CAROLINA ENERGY CONSERVATION CODE (IECC) 2009 WITH ASHRAE/IES 90.1 2009 EDITION
4,180 SQ. FT. ON SECOND FLOOR = 28 SECOND FLOOR OCCUPANTS
MAG
SHEET
NO. DESCRIPTION OF DRAWINGS
A1.1 CODE ANALYSIS, PROPERTY PHOTO, & PROJECT DATA
ARCHITECTURAL SHEETS
PROJECT SCOPE
DISCLAIMERS
INDEX OF DRAWINGS
A2.1 EXISTING FLOOR PLANS & PHOTOS
SITE
A2.2
RENOVATION NOTE
RENOVATIONS TO
TIGERVILLE FIRE STATION
2605 SC-414, TRAVELERS REST, SC 29690
A.F.F.
ADJ.
ALT.
ALUM.
ANOD.
ARCH.
A.P.
BRG.
BPL.
BVL.
BIT.
BLK.
BLKG.
BD.
BOT.
BLDG.
CAB.
CPT.
CLG.
C.T.
COL.
CONC.
C.M.U.
CONST.
C.J.
CORR.
CS.
DTL.
DIAG.
DIAM.
DISP.
DR.
D.S.
DWG.
E.D.F.
ELEC.
ELEV.
EMER.
EQ.
EQUIP.
EXT.
F.O.F.
F.O.M.
F.O.S.
FBD.
FBGL.
FIN.
F.F.
F.E.
F.E.C.
FP.
FLR.
F.D.
FTG.
FND.
GA.
GALV.
G.C.
GL.
G.B.
GWB.
HDWD.
HDWE.
HDR.
HTG.
INSUL.
ABOVE FIN. FLR.
ADJACENT
ALTERNATE
ALUMINUM
ANODIZED
ARCHITECT OR ARCHITECTURAL
ACOUSTICAL PANEL
BEARING
BEARING PLATE
BEVELED
BITUMINOUS
BLOCK
BLOCKING
BOARD
BOTTOM
BUILDING
CABINET
CARPET
CEILING
CERAMIC TILE
COLUMN
CONCRETE
CONC. MASONRY UNIT
CONSTRUCTION
CONTROL JOINT
CORRUGATED
COURSE OR COURSES
DETAIL
DIAGONAL
DIAMETER
DISPENSER
DOOR
DOWNSPOUT
DRAWING
ELEC. DRINKING FOUNTAIN
ELECTRIC OR ELECTRICAL
ELEVATION
EMERGENCY
EQUAL
EQUIPMENT
EXTERIOR
FACE OF FINISH
FACE OF MASONRY
FACE OF STUD
FIBERBOARD
FIBERGLASS
FINISH OR FINISHED
FINISHED FLOOR
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FIRE PROOF
FLOOR
FLOOR DRAIN
FOOTING
FOUNDATION
GAGE OR GAUGE
GALVANIZED
GENERAL CONTRACTOR
GLASS OR GLAZING
GRAB BAR
GYPSUM WALL BOARD
HARDWOOD
HARDWARE
HEADER
HEATING
INSULATED OR INSULATION
Project No.
Drawn by
Checked by
Date
Scale
Drawing Title Sheet
Of
This drawing is the property of ROBERT C. CASHION, ARCHITECT, INC. and is not to be reproduced or copied in whole or in part without written consent of the Architect. It is only to be used for the project and site specifically identified herein and is not to be used on any other project. It is to be returned upon request.1"=40'
RCC
RCC
2025-04
31 JULY 2025
Revisions
SHEET DATA
ABBREVIATIONS
PROPERTY PHOTO
A1.1 A
SCALE: 1"=40'
CODE ANALYSIS, PROPERTY
PHOTO, & PROJECT DATA
INT.
JT.
KPL.
KIT.
LAM.
LAV.
L.H.
MFR.
M.O.
MAX.
MECH.
MTL.
MIN.
MISC.
MTD
NOM
N.I.C.
N.T.S.
O.C.
OCC.
O.T.B.
O.D.
PNL.
P.BD.
PERF.
PERIM.
PLAS.
P.LAM.
PLYWD.
PVC.
P.S.F.
P.S.I.
P.T.
REINF.
RES.
RET.
R.H.
R.
RFG.
RM.
R.O.
SHT.
SIM.
SPEC.
SQ.
SQ. FT.
S.STL.
STD.
STL.
STOR.
S.D.
STRUC.
SUS.
SYS.
THR.
T.O.S.
T.O.W.
T.
TYP.
VCT
VERT
W.W.F.
W.
W/ W/O
WD.
INTERIOR
JOINT
KICKPLATE
KITCHEN
LAMINATE OR LAMINATED
LAVATORY
LEFT HAND
MANUFACTURER
MASONRY OPENING
MAXIMUM
MECHANICAL
METAL
MINIMUM
MISCELLANEOUS
MOUNTED
NOMINAL
NOT IN CONTRACT
NOT TO SCALE
ON CENTER
OCCUPANT OR OCCUPANTS
OPEN TO BELOW
OUTSIDE DIAMETER
PANEL
PARTICLE BOARD
PERFORATE OR PERFORATED
PERIMETER
PLASTER
PLASTIC LAMINATE
PLYWOOD
POLYVINYL CHLORIDE
POUNDS PER SQ. FT.
POUNDS PER SQ. IN.
PRESSURE TREATED
REINFORCED
RESILIENT
RETURN
RIGHT HAND
RISER
ROOFING
ROOM
ROUGH OPENING
SHEET
SIMILAR
SPECIFICATIONS
SQUARE
SQUARE FEET
STAINLESS STEEL
STANDARD
STEEL
STORAGE
STORM DRAIN
STRUCTURE OR STRUCTURAL
SUSPENDED
SYSTEM
THRESHOLD
TOP OF STEEL
TOP OF WALL
TREAD
TYPICAL
VINYL COMP. TILE
VERTICAL
WELDED-WIRE FABRIC
WIDE
WITH
WITHOUT
WOOD
DRAWING TITLE & SHEET NO.SEALS
ENLARGED SECOND FLOOR PLAN, SCHEDULES & DETAILS
ANY DEVIATION FROM THESE PLANS BY OWNER OR
CONTRACTOR MAY RESULT IN A NON-CODE CONFORMING
BUILDING. ADDITIONAL WORK ON THE PART OF THE
ARCHITECT OR HIS ENGINEERS WILL BE CHARGED TO THE
OWNER AS AN ADDED EXPENSE BEYOND BASIC DESIGN FEES.
THE USER(S) OF THIS DRAWING HEREBY AGREE(S) TO
INDEMNIFY, HOLD HARMLESS AND DEFEND THE ARCHITECT
AND HIS ASSIGNS AGAINST ANY AND ALL ACTIONS THAT
RESULT FROM THE USE OF THIS DRAWING. USE HEREOF
IMPLIES AGREEMENT.
THIS DRAWING IS AN INSTRUMENT OF CONDITIONAL
SERVICES. THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR
ACTUAL CONDITIONS, CONSTRUCTION, AND/OR USE
THEREOF. THIS DRAWING IS TO CONVEY DESIGN INTENTIONS
AND/OR CODE COMPLIANCE ONLY. USE OF THIS DRAWING
IMPLIES AGREEMENT WITH THESE CONDITIONS.
REF
PHONE (864) 836-7080
MARIETTA, SC 29661
2933 GEER HIGHWAY
ROBERT C. CASHION, ARCHITECT, INC.
EMAIL bcashion@rccarchitect.com
ARCHITECT
WEBSITE www.rccarchitect.com
A2.3
NOTE: PROPERTY INFORMATION
TAKEN FROM GREENVILLE
COUNTY GIS PROGRAM
ROBERT C.
CASHION
ARCHITECT, INC.
MARIETTA, SC
B85006
ST
AT
E
OF SOUTH CAROLIN
A
R E G
IS T ER ARCHIT
EC
T S
DE
ROBERT C.
CASHION
MARIETTA, SC
ST
AT
E
OF SOUTH CAROLIN
A
R E G
IS T ER ARCHIT
EC
T
DE
SC
-41
U S
A1.1
LOCATOR MAP
RENOVATION FLOOR PLANS
ROBERT C. CASHION, PRESIDENT
MAG
NORTH
GREENVILLE
UNIVERSITY
SC-290
SC-253
TIG
ERVILLE
GREER
TRAVELERS
REST
MARIETTA
SLATER
- GREENVILLE COUNTY -
TAX MAP #0650040100702
- NORTH GREENVILLE
JUNIOR COLLEGE -
TAX MAP #0650040100703
SC HWY 414
M
EA
D O
W
FO
RK
TIGERVILLE
FIRE STATION
SITE DATA:
OWNER: GREENVILLE COUNTY
TENANT: TIGERVILLE FIRE DEPARTMENT
LOT AREA: 2.49 ACRES
LOT FRONTAGE: 331 FEET
ZONING CLASS: UNZONED
INASMUCH AS THE REMODELING AND/OR REHABILITATION OF AN
EXISTING STRUCTURE REQUIRES THAT CERTAIN ASSUMPTIONS BE
MADE REGARDING EXISTING CONDITIONS, AND BECAUSE SOME OF
THE ASSUMPTIONS MAY NOT BE VERIFIABLE WITHOUT EXPENDING
ADDITIONAL SUMS OF MONEY OR DESTROYING OTHERWISE
ADEQUATE OR SERVICEABLE PORTIONS OF THE STRUCTURE, THE
ARCHITECT AND ENGINEERS SHALL NOT BE LIABLE FOR ANY LOSSES
OR EXPENSES ARISING FROM THE DISCOVERY OF CONCEALED OR
UNKNOWN CONDITIONS IN THE EXISTING STRUCTURE.
EXIST'G FIRE HYDRANT
GREENVILLE
TIGERVILLE
FIREBLOCKING IS REQUIRED IN COMBUSTIBLE CONSTRUCTION (SCBC 718.2)
FIRE RESISTANCE OF CORRIDOR WALLS IN BUILDINGS CONTAINING AN R OCCUPANCY = 0.5 HOURS
(SCBC SECTION 1020.2 & SCBC TABLE 1020.2)
AUTOMATIC HVAC EQUIPMENT SHUTDOWN VIA IN-DUCT SMOKE DETECTORS IS REQUIRED (SCMC 606).
A SINGLE STATION SMOKE ALARM SHALL BE INSTALLED IN THE SLEEPING AREA (SCBC 907.2.11.1)
DRAFTSTOPPING IS NOT REQUIRED IN ACCORDANCE WITH SCBC 718.4.
FIRE
RESISTANCE OF
STRUCTURE
A CLASS III STANDPIPE SYSTEM IS NOT REQUIRED (SCBC 905)
A MANUAL FIRE ALARM SYSTEM IS NOT REQUIRED (SCBC 907.2.2 & 907.2.7)
AN AUTOMATIC FIRE ALARM SYSTEM IS NOT REQUIRED (SCBC 907.2.2 & SCBC 907.2.4), BUT ONE EXISTS.
FIRE RESISTANCE RATINGS FOR BUILDING ELEMENTS APPLICABLE TO THIS PROJECT
(SCBC TABLES 601 & 705.5)
PRIMARY STRUCTURAL FRAME (COLUMNS, GIRDERS, TRUSSES) SUPPORTING A ROOF ONLY = 0
EXTERIOR LOAD BEARING WALLS = 0
INTERIOR LOAD BEARING WALLS = 0
EXTERIOR NONBEARING WALLS = 0 (AS PER SCBC 705.5)
INTERIOR NONBEARING WALLS = 0
FLOOR CONSTRUCTION = 0
ROOF CONSTRUCTION = 0
PROPERTY
PHOTO
REFLECTED CEILING PLANSA6.1
HANDICAP PARKING SPACE
- NORTH GREENVILLE
JUNIOR COLLEGE -
TAX MAP #0650040100700
- NORTH GREENVILLE
JUNIOR COLLEGE -
TAX MAP #0650040100700
- NORTH GREENVILLE
UNIVERSITY -
TAX MAP #0650040100714
TYGER MEADOW RD.
AutoCAD SHX Text
UP
This drawing is the property of ROBERT C.
CASHION, ARCHITECT, INC. and is not to be reproduced or copied in whole or in part without written consent of the Architect. It is only to be used for the project and site specifically identified herein and is not to be used on any other project. It is to be returned upon request.
Architects Planners Consultants
2933 GEER HIGHWAY
MARIETTA, SC 29661
Phone: (864) 836-7080
Seals
Project
Project No.
Drawn by
Checked by
Date
Scale
Revisions
Drawing Title
Sheet
Of
Robert C. Cashion Architect, Inc.
www.rccarchitect.com
Email: bcashion@rccarchitect.com
AN INTERIOR RENOVATION
FOR
TIGERVILLE
FIRE
DEPARTMENT
TIGERVILLE, SC
2025-08
RCC
RCC
6 JAN 2026
1/8"=1'-0"
EXISTING
FLOOR
PLANS
PHOTOS
A2.1
EXISTING FIRST FLOOR PLAN
SCALE: 1/8" = 1'-0"'
A A2.1
EXISTING SECOND FLOOR PLAN
SCALE: 1/8" = 1'-0"'
B A2.1
LOBBY
9,730 SQ FT THIS FLOOR
65 OCCUPANTS
4,180 SQ FT THIS FLOOR
28 OCCUPANTS
ASSIST. CHIEF'S
OFFICE
DISPATCH/
FIRE FIGHTERS
CAPTAIN'S
OFFICE
FIRE MARSHAL'S
OFFICE
CLOSET
CORRIDOR
CORRIDOR
BREAK
ROOM
CORRIDOR
CONFERENCE
ROOM
WOMEN
MEN
CORRIDOR
CORRIDOR
CHIEF'S
OFFICE
MED
CLOSET
STAIR
TRAINING
ROOM
ENTRY
STAIR
CASCADE
ROOM
MAINTENANCE
ROOM
ENTRY
GEAR
ROOM
FLUID
ROOM
YARD
EQUIPMENT
STAIR
TRUCK
BAYS
DAYROOM
BUNK
ROOM
STAIR
STORAGE
CORRIDOR
TOILET
TOILET
TOILET
MECH.
ROOM
FITNESS
ROOM
STORAGE
MEZZANINE
CLOSET
COVERED
PATIO
COMPUTER
COUNTER
SHELVES
HI-LO EDFs
REF
DW
RANGE &
HOODEXT. STEEL
STAIR
WALL CABINETS
BASE CABINETS
4" HIGH RAISED CONC.
EQUIPMENT PLATFORM
4" HIGH RAISED CONC.
EQUIPMENT PLATFORM
4" HIGH RAISED CONC.
EQUIPMENT PLATFORM SHELVES
SHELVES
SHELVES
SHELVES
RADIO ANTENNA
PATIO ROOF
BELOW
CORRUGATED METAL ROOF
(NO ATTIC SPACE)
EXT. STEEL
STAIR
RADIO ANTENNA
CORRUGATED METAL ROOF
(NO ATTIC SPACE)
ROBERT C.
CASHION
ARCHITECT, INC.
MARIETTA, SC
B85006
ST
AT
EO
FSOUTHCAROLINA
REGISTER ARCH
ITE
CT
S
DE
ROBERT C.
CASHION
MARIETTA, SC
ST
AT
EO
F SOUTHCAROLINA
REGISTER ARCH
ITE
CT
DE
CORRIDOR
BUNK
ROOM
209 DRESSING
ROOM
UNFINISHED
UNFINISHED
UNFINISHED
UNFINISHED
UNFINISHED
UNFINISHED
UNFINISHED
UNFINISHED
UNFINISHED
STAIR
STAIR
(UNFINISHED)
N
S
W EDIRECTION
REFERENCE KEY
LOBBY 101 CONFERENCE ROOM 110
BREAK ROOM 109 TRAINING ROOM 120 DAY ROOM 202 BUNK ROOM 203 TRUCK BAYS 121 UNFINISHED 2nd FLOOR
FRONT FACADE LEFT SIDE PHOTO REAR PHOTO RIGHT SIDE PHOTO
NEW WOOD STUD WALL W/ GWB ON BOTH SIDES
EXISTING WOOD STUD WALL TO BE REMOVED
EXISTING WALL STUDS TO RECEIVE GWB ON ONE SIDE
EXISTING WALL STUDS TO RECEIVE GWB ON BOTH SIDES
EXISTING WOOD WALL STUDS EXPOSED
EXISTING WOOD STUD WALL / 1/2" GWB BOTH SIDES
EXISTING WOOD STUD WALL / 1/2" GWB ONE SIDE
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN 1R
DN 1R
8' -0
8'
-0
20'-0" 4'-0"
27'-4"
NOTE: PROVIDE ADDITIONAL
"VAN ACCESSIBLE" SIGNAGE AT
LOCATIONS REQUIRED BY CODE
AND/OR AS INDICATED ON
DRAWINGS (GREEN LETTERING
ON WHITE BACKGROUND)
GALVANIZED STEEL CHANNEL
PAINTED TRAFFIC YELLOW
FINISH PAVING
NOTES:
1. SIGN SHALL CONFORM TO
U.S. MANUAL SPECIFICATIONS.
2. SIGN SHALL BE
REFLECTORIZED TO SHOW THE
SAME COLOR BY NIGHT AS BY
DAY.
3. SIGN SHALL BE SECURELY
MOUNTED ON GALVANIZED
STEEL CHANNEL POSTS.
4. INSTALL SIGN AT LOCATION
REQUIRED BY CODE AND/OR AS
INDICATED ON DRAWINGS.
CONFIRM ALL ACCESSIBLE
SIGNAGE CODES.
CONC. BASE
METAL HANDICAP PARKING
SPACE SIGN (GREEN
LETTERING, ARROW &
BORDER)
WHITE SYMBOL ON
BLUE SQUARE
WHITE BACKGROUND
5' -6
4'-8"
4"
This drawing is the property of ROBERT C.
CASHION, ARCHITECT, INC. and is not to be reproduced or copied in whole or in part without written consent of the Architect. It is only to be used for the project and site specifically identified herein and is not to be used on any other project. It is to be returned upon request.
Architects Planners Consultants
2933 GEER HIGHWAY
MARIETTA, SC 29661
Phone: (864) 836-7080
Seals
Project
Project No.
Drawn by
Checked by
Date
Scale
Revisions
Drawing Title
Sheet
Of
Robert C. Cashion Architect, Inc.
www.rccarchitect.com
Email: bcashion@rccarchitect.com
AN INTERIOR RENOVATION
FOR
TIGERVILLE
FIRE
DEPARTMENT
TIGERVILLE, SC
2025-08
RCC
RCC
6 JAN 2026
1/8"=1'-0"
RENOVATION
FLOOR
PLANS
HANDICAP
PARKING
DETAILS
A2.2
FIRST FLOOR RENOVATION PLAN
SCALE: 1/8" = 1'-0"
A A2.2
SECOND FLOOR RENOVATION PLAN
SCALE: 1/8" = 1'-0"'
B
A2.29,730 SQ FT = 65 OCCUPANTS 4,180 SQ FT = 28 OCCUPANTS
N
S
W EDIRECTION
REFERENCE KEY
ROBERT C.
CASHION
ARCHITECT, INC.
MARIETTA, SC
B85006
ST
AT
EO
FSOUTHCAROLINA
REGISTER ARCH
ITE
CT
S
DE
ROBERT C.
CASHION
MARIETTA, SC
ST
AT
EO
F SOUTHCAROLINA
REGISTER ARCH
ITE
CT
DE
DAYROOM
GAME
ROOM
STAIR
STORAGE
CORRIDOR
BUNK
ROOM
TOILET
TOILET
TOILET
CORRIDOR
BUNK
ROOM
BUNK
ROOM
BUNK
ROOM
MECH.
ROOM
ALCOVE
BUNK
ROOM
BUNK
ROOM
BUNK
ROOM
FITNESS
ROOM
STORAGE
ROOM
PATIO ROOF
BELOW
EXT. STEEL
STAIR
RADIO ANTENNA
CORRUGATED METAL ROOF
(NO ATTIC SPACE)
79 SF
83 SF541 SF
86 SF
116 SF
83 SF
250 SF
114 SF
118 SF
114 SF
46 SF46 SF46 SF
135 SF
339 SF
658 SF
809 SF
LOBBY
ASSIST. CHIEF'S
OFFICE
DISPATCH/
FIRE FIGHTERS
CAPTAIN'S
OFFICE
FIRE MARSHAL'S
OFFICE
CLOSET
CORRIDOR
CORRIDOR
BREAK
ROOM
CORRIDOR
CONFERENCE
ROOM
WOMEN
MEN
CORRIDOR
CORRIDOR
CHIEF'S
OFFICE
MED
CLOSET
STAIR
TRAINING
ROOM
ENTRY
STAIR
CASCADE
ROOM
MAINTENANCE
ROOM
FIRE TREE
ROOM
GEAR
ROOM
FLUID
ROOM
YARD
EQUIPMENT
STAIR
TRUCK
BAYS
CLOSET
COVERED
PATIO
COMPUTER
COUNTER
SHELVES
HI-LO EDFs
REF
DW
RANGE &
HOODEXT. STEEL
STAIR
WALL CABINETS
BASE CABINETS
4" HIGH RAISED CONC.
EQUIPMENT PLATFORM
4" HIGH RAISED CONC.
EQUIPMENT PLATFORM
4" HIGH RAISED CONC.
EQUIPMENT PLATFORM SHELVES
SHELVES
SHELVES
SHELVES
RADIO ANTENNA
CORRUGATED METAL ROOF
(NO ATTIC SPACE)
4'x7' FENCED SPRINKLER
VALVE TREE CAGE W/
32" GATE
NOTE:
NO RENOVATIONS ARE TO BE MADE ON
THIS FLOOR OTHER THAN INSTALLATION
OF A SPRINKLER SYSTEM.
EXITWAY
42 SF
STAIR
STAIR
ACCESSIBLE PARKING SPACE PLAN
SCALE: 1/4" = 1'-0"
C
A2.2 SCALE: 1/2"= 1'-0"
J
A2.1SCALE: 1/2"= 1'-0"
J A2.1
ACCESSIBLE PARKING
SIGN DETAIL
ACCESSIBLE
PARKING SYMBOL DETAIL
NOTE: ALL PAINT STRIPES TO
BE 6" WIDE HANDICAP
ACCESSIBLE BLUE
ED
G E
O F
PA
V
EM
EN
T
NEW WOOD STUD WALL W/ GWB ON BOTH SIDES
EXISTING WOOD STUD WALL TO BE REMOVED
EXISTING WALL STUDS TO RECEIVE GWB ON ONE SIDE
EXISTING WALL STUDS TO RECEIVE GWB ON BOTH SIDES
EXISTING WOOD WALL STUDS EXPOSED
EXISTING WOOD STUD WALL / 1/2" GWB BOTH SIDES
EXISTING WOOD STUD WALL / 1/2" GWB ONE SIDE
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN 1R
AutoCAD SHX Text
DN 1R
AutoCAD SHX Text
PARKING
AutoCAD SHX Text
RESERVED
AutoCAD SHX Text
ACCESSIBLE
VAN
ROOM FINISHES:
ROOMS FLOORS BASE WALLS CEILINGS
ROOM NAME MATERIALS MAT. MATERIALS MATERIAL HEIGHT
A.F.F.NORTH EAST SOUTH WEST
RO
OM
N O.
1 2 3 1 2 3 1 2 3 1 2 101-129
FIRST FLOOR
RO
OM
N O.
S.
A.
T
GAME ROOM
11 8'-0"
STORAGE
CORRIDOR
DAY ROOM
TOILET
8'-0"
8'-0"
1 2 3 1 2 3 1 2 3 3
VC
T
CA
RP
ET
EX
IS
TIN
G
TO
R
EM
AI
N
VI
NY
L W
OO
D
GW
B
PA
IN
TE
D
OP
EN
TO
A
DJ
AC
EN
T S
PA
CE
STAIR
101-129
1 1 1
1 1
JAMBW H MAT.T TYPE GLASS TYPEMAT. HEAD SILL
DOOR SCHEDULE:
DOOR
NO.
SIZE
DOOR FRAME
DETAILS
REMARKS
FIRE
RATING
LABEL
DOOR
NO.
6'-8" 1 3/4"
1 3/4" H.M.
REPLACE EXISTING MASONITE
A3'-0"
1 3/4" SC WD. H.M. A3'-0"
3'-0" EXIST'G
H1 J1 S1
1 3/4"
1 3/4"08 08
09 09
10 10
1 3/4"
SC WD.
3'-0"
SC WD. H.M.
3'-0"
2'-0"
1 3/4"
1 3/4"
1 3/4"
2 3
Colors to be selected by Fire Chief.
All metal door frames are to be painted.
All wood cabinets and shelving are to be stained.
All wood doors are to be stained.
Install vinyl base in toe spaces of cabinets.1.
2.
3.
4.
5.
3 3
EX
IS
TIN
G
TO
R
EM
AI
N
7'-8"
1 3/4"3'-0"
1 3/4" H.M.3'-0"
30 MIN
13 13
14 14
15 15
16 16
1 3/4" H.M.3'-0"
1 3/4"
1 3/4"
1 3/4"
1 3/4" H.M. A3'-0"
GW
B
PA
IN
TE
D
OP
EN
TO
A
DJ
AC
EN
T S
PA
CE
EX
IS
TIN
G
TO
R
EM
AI
N
GW
B
PA
IN
TE
D
OP
EN
TO
A
DJ
AC
EN
T S
PA
CE
EX
IS
TIN
G
TO
R
EM
AI
N
GW
B
PA
IN
TE
D
OP
EN
TO
A
DJ
AC
EN
T S
PA
CE
EX
IS
TIN
G
TO
R
EM
AI
N
EX
IS
TIN
G
TO
R
EM
AI
N
EX
IS
TIN
G
TO
R
EM
AI
N
3 3 3 3 3
GW
B
PA
IN
TE
D
207 TOILET
208 TOILET
209 CORRIDOR
210 BUNK ROOM
214 ALCOVE
215 MECH. ROOM
216 EXITWAY
217 FITNESS ROOM
218 BUNK ROOM
219 BUNK ROOM
BUNK ROOM
BUNK ROOM
BUNK ROOM
220 BUNK ROOM 220
3 3 3 33 3 3 3 3 3 3 3 3
3 3 3 11 1 1
3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
11 1 1 1 2 2 1 1 1 1 2 2 1 1 1 1 2 2 1 1 1 1 2 2 1 1 1 1
2 2 1 1 1 1 2 2 1 1 1 1 2 2 1 1 1 1
3 32 3 1 1 1 1 1 1 1 1 1 1 1 1
8'-0" 8'-0" 8'-0" 8'-0" 8'-4"
8'-0" 8'-0" 8'-0"
8'-4" 8'-4" 8'-4" 8'-4" 8'-4"
8'-4" 8'-4" 8'-4"
17 171 3/4" H.M.4'-0" EXISTING DOOR & FRAME TO REMAIN
SC WD.
SC WD.
SC WD.
SC WD.
SC WD.
SC WD.
SC WD.
SC WD.
SC WD.
STEEL
SC WD.
SC WD.
SC WD.
SC WD.
REPLACE EXISTING MASONITE
REPLACE EXISTING MASONITE
REPLACE EXISTING MASONITE
30 MIN
30 MIN
30 MIN
30 MIN
30 MIN
30 MIN
30 MIN
30 MIN
30 MIN
30 MIN
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
3'-0"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
6'-8"
NONE
REPLACE EXISTING MASONITE
EXIST'G
EXIST'G
EXIST'G
EXIST'G
H.M.
H.M.
H.M.
H.M.
H.M.
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
H1 J1 S1
H1 J1 S1
H1 J1 S1
H1 J1 S1
H1 J1 S1
H1 J1 S1
H1 J1 S1
H1 J1 S1
H1 J1 S1
H1 J1 S1
NOTES
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
D O
O R
T
YP
E 1/
4"
'-0
A
2" HOLLOW
METAL HEAD
2" HOLLOW
METAL JAMBS
FR
AM
E
TY
PE
1/
4"
'-0
A
Provide keying system to include a Master key to open all doors, entrance doors keyed alike, and interior doors keyed differently except 2 or more doors to same room to be keyed alike.
Hardware Schedule to be compiled by Contractor's hardware consultant and submitted to the Architect for approval prior to ordering.
2.
1.
NOTES:
221 STAIR 2013 3
222 STORAGE ROOM 2013 3
223 STAIR 2013 3
1 1 1 1 1 1 1 1 1 1 1 1
8'-0" 8'-0" 8'-0"
NO RENOVATIONS TO BE MADE ON FIRST FLOOR
2" H.M. FRAME
DOUBLE
WD. STUDS
DOOR AS SPEC'D.
2x4 WD. STUDS @ 16" O.C.
2" H.M. FRAME
DOOR AS SPEC'D.
5/8" GWB EA. SIDE
FRAME BEYOND
5/8" GWB EA. SIDE
H.M. FRAME BEYOND
DOOR AS SPEC'D
FLITCH HEADER
OF 2x6's & 1/2"
PLYW'D PLATES
2x4 WD. STUDS @ 16" O.C.
HEAD H1
JAMB J1
SILL S1
This drawing is the property of ROBERT C.
CASHION, ARCHITECT, INC. and is not to be reproduced or copied in whole or in part without written consent of the Architect. It is only to be used for the project and site specifically identified herein and is not to be used on any other project. It is to be returned upon request.
Architects Planners Consultants
2933 GEER HIGHWAY
MARIETTA, SC 29661
Phone: (864) 836-7080
Seals
Project
Project No.
Drawn by
Checked by
Date
Scale
Revisions
Drawing Title
Sheet
Of
Robert C. Cashion Architect, Inc.
www.rccarchitect.com
Email: bcashion@rccarchitect.com
AN INTERIOR RENOVATION
FOR
TIGERVILLE
FIRE
DEPARTMENT
TIGERVILLE, SC
2025-08
RCC
RCC
6 JAN 2026
1/8"=1'-0"
ENLARGED
SECOND
FLOOR
PLAN,
SCHEDULES,
DETAILS
A2.3
ENLARGED SECOND FLOOR PLAN
SCALE: 1/4" = 1'-0"'
A A2.3
E
W
N S
DIRECTION
REFERENCE
KEY
ROBERT C.
CASHION
ARCHITECT, INC.
MARIETTA, SC
B85006
ST
AT
EO
FSOUTHCAROLINA
REGISTER ARCH
ITE
CT
S
DE
ROBERT C.
CASHION
MARIETTA, SC
ST
AT
EO
F SOUTHCAROLINA
REGISTER ARCH
ITE
CT
DE
DAYROOM
GAME
ROOM
STAIR
STORAGE
CORRIDOR
BUNK
ROOM
TOILET
TOILET
TOILET
CORRIDOR
BUNK
ROOM
BUNK
ROOM
BUNK
ROOM
MECH.
ROOM
ALCOVE
BUNK
ROOM
BUNK
ROOM
BUNK
ROOM
FITNESS
ROOM
PATIO ROOF
BELOW
EXT. STEEL
STAIR
RADIO ANTENNA
CORRUGATED METAL ROOF
(NO ATTIC SPACE)
79 SF83 SF
541 SF
86 SF116 SF
83 SF
185 SF
114 SF
118 SF114 SF
46 SF
46 SF
46 SF
135 SF
339 SF
658 SF
GENERAL FLOOR PLAN NOTES
1. INTERIOR DIMENSIONS AT EXISTING FINISHED WALLS ARE TO FACE
OF DRYWALL.
2. INTERIOR DIMENSIONS AT NEW WALLS ARE TO FACE OF STUD.
3. ALL INTERIOR WALLS AT SECOND FLOOR ARE NON-LOAD BEARING.
8. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL
EXISTING CONDITIONS AND TO NOTIFY THE ARCHITECT (IN
WRITING) IF DESCREPANCIES ARE FOUND.
4. ALL NEW INTERIOR WALLS AND EXISTING UNFINISHED INTERIOR
WALL STUDS AT SECOND FLOOR ARE TO RECEIVE 1 LAYER OF 5/8"
DRYWALL ON EACH SIDE.
6. CEILINGS IN SLEEPING ROOMS AND IN ROOMS ADJACENT TO
THEM SHALL BE 2 LAYERS OF 5/8" TYPE-X GWB.
9. INASMUCH AS RENOVATING AN EXISTING STRUCTURE REQUIRES
THAT CERTAIN ASSUMPTIONS BE MADE REGARDING EXISTING
CONDITIONS, AND BECAUSE SOME OF THE ASSUMPTIONS MAY
NOT BE VERIFIABLE WITHOUT EXPENDING ADDITIONAL SUMS OF
MONEY OR DESTROYING OTHERWISE ADEQUATE OR
SERVICEABLE PORTIONS OF THE STRUCTURE, THE ARCHITECT
AND ENGINEERS SHALL NOT BE LIABLE FOR ANY LOSSES OR
EXPENSES ARISING FROM THE DISCOVERY OF CONCEALED OR
UNKNOWN CONDITIONS IN THE EXISTING STRUCTURE.
CONSTRUCT WALL TO
CONCEAL EXISTING DUCTWORK
REPLACE EXIST'G DOOR W/ NEW
3068 SOLID CORE DOOR TO SWING
IN DIRECTION OF EGRESS AS
SHOWN WITH MINIMUM 18
INCHES CLEAR SPACE ON STRIKE
SIDE OF DOOR
EXISTING
52"x30" AREA
OF REFUGE
5. ALL NEW INTERIOR WALLS AND EXISTING UNFINISHED INTERIOR
WALL STUDS AT SECOND FLOOR ARE TO RECEIVE 1 LAYER OF 5/8"
DRYWALL ON EACH SIDE.
7. NEW DOORS ARE TO BE 20 MIN. RATED 3068 SOLID CORE WOOD.
REMOVE EXISTING DOOR
& WALL UP OPENING
EXISTING WALLS
TO BE REMOVED
REMOVE EXISTING DOOR
& WALL AS SHOWN
INSTALL NEW DOOR
HERE AS SHOWN
EXISTING WALLS
TO BE REMOVED
NOTE:
WHERE AN ESCAPE WINDOW CANNOT BE PROVIDED FROM A SLEEPING ROOM, A
PROTECTED PATH OF ESCAPE FROM THE SLEEPING ROOM TO THE EXTERIOR SHALL
BE PROVIDED & THE SLEEPING ROOM WALLS & CEILINGS SHALL BE 1-HOUR
RATED. THE PATH OF EGRESS FROM THE SLEEPING ROOM TO THE EXTERIOR SHALL
HAVE 1-HOUR RATED WALLS & CEILINGS, & THE CEILINGS OF ALL ROOMS
ADJACENT TO THESE AREAS SHALL BE 1-HOUR RATED. THEREFORE, ALL NEW
WALLS PLUS THE WALLS SEPARATING ROOMS 213 & 215 SHALL BE 1-HOUR RATED
WITH 1 LAYER OF 5/8" TYPE-X DRYWALL ON EACH SIDE, & THE CEILINGS IN AREAS
204, 205, 209, 210, 211, 212, 213, 214, 215, 216, 217, 218, & 219 SHALL BE 1-HOUR RATED WITH 2 LAYERS OF 5/8" TYPE-X GWB ON BOTTOM OF 2x6 CEILING JOISTS
@ 16" OC.
EXITWAY
41 SF
REMOVE EXISTING PANELING &
REPLACE WITH 5/8" TYPE-X GWB
INSTALL NEW WALL-
HUNG LAVATORY
4'-0 3/4"
07 14
DOOR DETAILS
SCALE: 1/4" = 1'-0"'
B A2.3
NEW WOOD STUD WALL W/ GWB ON BOTH SIDES
EXISTING WOOD STUD WALL TO BE REMOVED
EXISTING WALL STUDS TO RECEIVE GWB ON ONE SIDE
EXISTING WALL STUDS TO RECEIVE GWB ON BOTH SIDES
EXISTING WOOD WALL STUDS EXPOSED
EXISTING WOOD STUD WALL / 1/2" GWB BOTH SIDES
EXISTING WOOD STUD WALL / 1/2" GWB ONE SIDE
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN 1R
DN 1R
HVAC SUPPLY
CEILING DIFFUSER
2' x 4' LAY-IN LIGHT FIXTURE
CEILING MATERIAL LEGEND
HVAC RETURN AIR
CEILING GRILLE
EXHAUST FAN
SURFACE MOUNTED
LIGHT FIXTURE
2'x4' SUSPENDED
CEILING TILES
EF
2'x2' SUSPENDED
CEILING TILES
2'x4' VINYL-FACED
SUSPENDED CEILING TILES
NO CEILING - OPEN TO FLOOR
FRAMING OR ROOF ABOVE
SMOOTH TEXTURE
INTERIOR GYP. BD.
EF
EF
CEILING MOUNTED EXIT SIGN
CEILING MOUNTED EXIT
SIGN & EMERGENCY LIGHT
CEILING MOUNTED
TELEPHONE SIGNAL BOOSTER
CEILING MOUNTED
SMOKE DETECTOR
CEILING MOUNTED
SECURITY CAMERA
RECESSED CEILING SPEAKER
This drawing is the property of ROBERT C.
CASHION, ARCHITECT, INC. and is not to be reproduced or copied in whole or in part without written consent of the Architect. It is only to be used for the project and site specifically identified herein and is not to be used on any other project. It is to be returned upon request.
Architects Planners Consultants
2933 GEER HIGHWAY
MARIETTA, SC 29661
Phone: (864) 836-7080
Seals
Project
Project No.
Drawn by
Checked by
Date
Scale
Revisions
Drawing Title
Sheet
Of
Robert C. Cashion Architect, Inc.
www.rccarchitect.com
Email: bcashion@rccarchitect.com
AN INTERIOR RENOVATION
FOR
TIGERVILLE
FIRE
DEPARTMENT
TIGERVILLE, SC
2025-08
RCC
RCC
6 JAN 2026
1/8"=1'-0"
REFLECTED
CEILING
PLANS
A6.1
FIRST FLOOR REFLECTED CEILING PLAN
SCALE: 1/8" = 1'-0"'
A A6.1
SECOND FLOOR REFLECTED CEILING PLAN
SCALE: 1/8" = 1'-0"'
A A6.1
ROBERT C.
CASHION
ARCHITECT, INC.
MARIETTA, SC
B85006
ST
AT
EO
FSOUTHCAROLINA
REGISTER ARCH
ITE
CT
S
DE
ROBERT C.
CASHION
MARIETTA, SC
ST
AT
EO
F SOUTHCAROLINA
REGISTER ARCH
ITE
CT
DE
NOTE: NO RENOVATIONS ARE TO BE MADE ON THIS FLOOR
OTHER THAN INSTALLATION OF A SPRINKLER SYSTEM.
NEW WOOD STUD WALL W/ GWB ON BOTH SIDES
EXISTING WOOD STUD WALL TO BE REMOVED
EXISTING WALL STUDS TO RECEIVE GWB ON ONE SIDE
EXISTING WALL STUDS TO RECEIVE GWB ON BOTH SIDES
EXISTING WOOD WALL STUDS EXPOSED
EXISTING WOOD STUD WALL / 1/2" GWB BOTH SIDES
EXISTING WOOD STUD WALL / 1/2" GWB ONE SIDE
| Sheets and Views |
| 2025-08 Tigerville FD-A1.1 Cover |
| 2025-08 Tigerville FD-A2.1 Ex FPs |
| 2025-08 Tigerville FD-A2.2 FPs |
| 2025-08 Tigerville FD-A2.3 Enlarged FP |
| 2025-08 Tigerville FD-A6.1 RCPs |
File details come from the government source that posted it. Updated .