2024-107 - Morgan CC Wray Campus T.I. - Addendum #1 - Code Review Documents Combined.pdf
PDF 9 MB Posted
- Attached to
- 2024-107 Wray Facility Renovation
- Solicitation number
- 2024-107
- Issued by
- Ouray County, Weston CDP, Colorado
About this file
This document is a comprehensive set of construction design and specifications for the Morgan Community College Wray Campus Tenant Improvement (T.I.) project located at 300 Dexter Street in Wray, Colorado. The project involves renovating approximately 2,330 square feet of an existing building previously used as a convenience store/gas station, transforming it into a functional educational space. The renovation will include classrooms, computer labs, offices, restrooms, and support spaces, with an anticipated construction timeline spanning from July 2024 to February 2025. The design documents, prepared by Architectural Workshop in Denver, include detailed architectural, mechanical, electrical, and plumbing plans, and were developed through multiple design stages, with the most recent addendum focused on code review dated February 24, 2025.
The project is funded through Morgan Community College and involves a comprehensive renovation that includes replacing existing finishes, upgrading mechanical and electrical systems, and refreshing the building's exterior. The design emphasizes accessibility, energy efficiency, and compliance with the 2021 International Building Code and related standards. The total project budget is not explicitly stated, but the extensive documentation suggests a thorough approach to the renovation. The project includes alternate bid options, such as removing existing faux CMU paneling and installing new metal panel systems on different building facades. The renovation will maintain the existing electrical service and main distribution panel, with updates to lighting, power systems, and building systems to meet current educational facility standards.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LOCATION MAP:
PROJECT LOCATION TRUE NORTH
300 DEXTER ST
WRAY CO, 80758
CONTACTS:
MORGAN COMMUNITY COLLEGE
423 MAIN STREET, STE. G
WRAY, CO 80758
970-332-5755
CONTACT: GENE KIND
BUILDING
OWNER:
ARCHITECT:
MECHANICAL:
ARCHITECTURAL WORKSHOP
2 KALAMATH ST.
DENVER, CO 80223
303-788-1717
CONTACT: JOE MARSHALL, AIA
PLUMBING:
ELECTRICAL:
RJA ENGINEERING
3310 LAWRENCE STREET, SUITE 2
DENVER, CO 80205
720-598-0774
CONTACT: DARIN RAMIREZ
RJA ENGINEERING
3310 LAWRENCE STREET, SUITE 2
DENVER, CO 80205
720-598-0774
CONTACT: DARIN RAMIREZ
RJA ENGINEERING
3310 LAWRENCE STREET, SUITE 2
DENVER, CO 80205
720-598-0774
CONTACT: DARIN RAMIREZ
MORGAN COMMUNITY COLLEGE
PROJECT NO.: INITIAL DATE:
DRAWN BY: CHECKED BY:
ARCHITECTURAL WORKSHOP . DENVER, COLORADO
A R
C H
IT
E
C T
U R
A L
W O
R K
S H
O P
, L
LC
. A
LL
R
IG
H T
S R
E S
E R
V E
D
2417mcc JUNE 2024
ZEAP JM
2024-107_MORGAN CC
WRAY CAMPUS T.I.
300 DEXTER ST
WRAY CO, 80758
G-001
COVER SHEET
ADDENDUM #1 - CODE REVIEW
FEBRUARY 24, 2025
2024-107_MORGAN CC WRAY CAMPUS T.I.
300 DEXTER ST
WRAY CO, 80758
G-001 COVER SHEET
G-002 PROJECT AND CODE INFORMATION
G-003 ACCESSIBILITY INFORMATION
G-004 PROJECT INFORMATION
AS-101 ARCHITECTURAL SITE PLAN
AD-101 DEMO PLAN
AD-103 DEMO CEILING PLAN
A-101 CONSTRUCTION PLAN
A-102 FURNITURE PLAN
A-103 CEILING PLAN
A-201 EXTERIOR ELEVATIONS
A-202 EXTERIOR ELEVATIONS
A-401 INTERIOR ELEVATIONS
A-501 DETAILS
A-502 DETAILS
A-503 DETAILS
A-601 DOOR & WINDOW SCHEDULE
I-101 INTERIOR FINISH PLAN & FINISH SCHEDULE
SHEET INDEX:
DATE DESCRIPTION
07/19/2024 100% DESIGN DEVELOPMENT
12/05/2024 100% CONSTRUCTION DOCUMENTS
02/24/2025 ADDENDUM #1 - CODE REVIEW
MP0.0
MECHANICAL AND PLUMBING LEGEND AND GENERAL
NOTES
MP0.1 MECHANICAL AND PLUMBING SPECIFICATIONS
MP0.2 COMCHECK
MP0.3 COMCHECK
MP0.4 MECHANICAL AND PLUMBING SCHEDULES
MD1.0 MECHANICAL DEMOLITION PLAN
M1.0 MECHANICAL LEVEL ONE PLAN
M1.1 MECHANICAL ROOF PLAN
PD1.0 WASTE AND VENT PLUMBING DEMOLITION PLAN
PD2.0 DOMESTIC WATER & GAS DEMOLITION PLAN
P1.0 WASTE & VENT LEVEL ONE PLAN
P2.0 DOMESTIC WATER & GAS LEVEL ONE PLAN
P2.1 DOMESTIC WATER & GAS ROOF PLAN
E0.0 ELECTRICAL LEGEND
E0.1 ELECTRICAL COMCHECK
E0.2 ELECTRICAL ONE-LINE DIAGRAM
E0.3 ELECTRICAL SCHEDULES
ED1.0 POWER PLANS
E1.0 POWER PLANS
E1.1 POWER PLANS
E2.0 LIGHTING PLANS
E2.1 LIGHTING PLANS
WH
CODE DATA:
BUILDING ADDRESS: 300 DEXTER ST
WRAY CO, 80758
APPLICABLE BUILDING CODES: 2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 INTERNATIONAL FUEL GAS CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 INTERNATIONAL PLUMBING CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2023 NATIONAL ELECTRICAL CODE
2021 INTERNATIONAL FIRE CODE
ICC A117.1-2017 AMERICAN NATIONAL STANDARD -
ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES.
BUILDING HEIGHT: 14'-0"
BUILDING CONSTRUCTION: TYPE V-B
OCCUPANCY GROUP: B - BUSINESS
SPRINKLER SYSTEM: NO
CONSTRUCTION AREA: 1ST FLOOR 2,330 S.F.
TOTAL: 2,330 S.F.
CHAPTER 5
TABLE 504.3 - MAX. BUILDING HEIGHT ABOVE GRADE PLANE
TABLE 504.4 - # OF STORIES ABOVE GRADE PLANE
TABLE 506.2 - ALLOWABLE AREA FACTOR
SECTION 508.2.3 ALLOWABLE BUILDING AREA
AGGREGATE ACCESSORY OCCUPANCIES SHALL NOT OCCUPY MORE
THAN 10 PERCENT OF THE FLOOR AREA OF THE STORY IN WHICH
THEY ARE LOCATED AND SHALL NOT EXCEED TABULAR VALUES FOR
NONSPRINKLERED BUILDINGS IN TABLE 506.2 FOR EACH SUCH
ACCESSORY OCCUPANCY.
ALLOWED PROVIDED
CHAPTER 6
TABLE 601, FIRE RESISTANCE REQUIREMENTS FOR BUILDING ELEMENTS: TYPE V-B CONSTRUCTION = NO RATINGS REQUIRED
CHAPTER 10
TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCE PER OCCUPANT
BUSINESS (1 PERSON/ 150 GROSS S.F.) = 9 OCC.
CLASSROOM AREA (1 PERSON/ 20 NET S.F.) = 44 OCC.
ACCESSORY STOR. / MECH. AREA (1 PERSON / 300 GROSS S.F.) = 1 OCC.
SECTION 1005.3.2 OTHER EGRESS COMPONENTS
EGRESS WIDTH FOR COMPONENTS OTHER THAN STAIRS = 0.2"/OCC.
SECTION 1005.7.1 DOORS, WHEN FULLY OPENED, SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE THAN 7". DOORS IN ANY POSITION SHALL NOT
REDUCE THE REQUIRED WIDTH BY MORE THAN ONE-HALF.
SECTION 1006.3.3 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
OCCUPANT LOAD: 1-500 REQUIRES A MINIMUM OF 2 EXITS
SECTION 1007.1.1 TWO EXITS OR EXIT ACCESS DOORWAYS
WHERE TWO EXITS, EXIT ACCESS DOORWAYS, EXIT ACCESS STAIRWAYS OR RAMPS,
OR ANY COMBINATION THEREOF, ARE REQUIRED FROM ANY PORTION OF THE EXIT ACCESS, THEY SHALL BE PLACED A DISTANCE APART EQUAL TO NOT LESS THAN ONE HALF OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING OR AREA TO BE SERVED MEASURED IN A
STRAIGHT LINE BETWEEN THEM.
MAXIMUM OVERALL DIAGONAL DIMENSION: 76'-0"
EXIT SEPARATION DISTANCE: 41'-3"
SECTION 1010.1.1 SIZE OF DOOR
MIN. 32" CLEAR WIDTH WITH DOOR IN THE 90 DEG. OPEN POSITION.
SECTION 1017.2 EXIT ACCESS TRAVEL DISTANCE
MAXIMUM TRAVEL DISTANCE = 200' - 0"; PROVIDED = 74' - 11"
CHAPTER 7
TABLE 705.5, FIRE RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE
TYPE V-B CONSTRUCTION 10'-0" ≤ X < 30'-0" SEPARATION = NO RATINGS REQUIRED.
TYPE V-B CONSTRUCTION >30'-0" SEPARATION = NO RATINGS REQUIRED.
TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS
10 TO LESS THAN 15; UNPROTECTED NON-SPRINKLERED = 15%
PROTECTED = 45%
30 OR GREATER; UNPROTECTED NON-SPRINKLERED = NO LIMIT
PROTECTED = NO LIMIT
40'
15,750 S.F.
14'-0"
2,330 S.F.
CHAPTER 9
SPRINKLERS: SECTION 903.2.1.3 : NOT PROVIDED
FIRE ALARM: SECTION 907.2.1: NOT PROVIDED
SECTION 906.3.(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
ORDINARY (MODERATE) HAZARD OCCUPANCY
MINIMUM-RATED SINGLE FIRE EXTINGUISHER: 2-A
MAXIMUM FLOOR AREA PER UNIT OF A: 1,500 SQUARE FEET
MAXIMUM FLOOR AREA PER EXTINGUISHER: 11,250 SQUARE FEET
MAXIMUM DISTANCE OF TRAVEL TO EXTINGUISHER: 75 FEET
CHAPTER 8
TABLE 803.13 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY
GROUP B
EXIT PASSAGEWAYS: A
CORRIDORS: B
ROOMS AND ENCLOSED SPACES: C
CHAPTER 29
CODE STUDY KEY
ACC. STOR / MECH.
BUSINESS
CLASSROOM
541 SF
28 OCC.
CLASSROOM
B
169 SF
1 OCC.
ACC. STOR / MECH.
B
304 SF
16 OCC.
CLASSROOM
B
1291 SF
9 OCC.
BUSINESS
B
MAXIMUM DIAGONAL DISTANCE: 76'-0"
E X
IT
S
E P
E R
A
TI
O N
D
IS
TA
N
C E
: 4 1'
-3
74' - 11"
DEAD END
LENGTH = 12'-5"
LAB /
CLASSROOM
UTILITY /
STORAGE
UNISEX
RESTROOM
UNISEX
RESTROOM
OFFICE
LOBBY
OFFICE
EXIT
ACCESS
OPEN
OFFICE
COMPUTER
LAB
EXIT DOORWAY CLEAR WIDTH
18 OCC. X 0.2 = 3.6"
PROVIDED 36"
EXIT DOORWAY CLEAR WIDTH
18 OCC. X 0.2 = 3.6"
PROVIDED 36"
(B)
(B)
(B)
BREAKROOM
EXIT DOORWAY CLEAR WIDTH
18 OCC. X 0.2 = 3.6"
PROVIDED 36"
53' - 3"
PROJECT NO.: INITIAL DATE:
DRAWN BY: CHECKED BY:
ARCHITECTURAL WORKSHOP . DENVER, COLORADO
A R
C H
IT
E
C T
U R
A L
W O
R K
S H
O P
, L
LC
. A
LL
R
IG
H T
S R
E S
E R
V E
D
2417mcc JUNE 2024
ZEAP JM
2024-107_MORGAN CC
WRAY CAMPUS T.I.
300 DEXTER ST
WRAY CO, 80758
G-002
PROJECT AND CODE INFORMATION
1/4" = 1'-0"1 FIRST FLOOR CODE STUDY
OCCUPANCY LOAD SCHEDULE
NAME
OCCUPANCY
GROUP AREA AREA PER OCCUPANT NUMBER OF OCCUPANTS
ACC. STOR. / MECH B PER PLAN 300 SF 1
BUSINESS B PER PLAN 150 SF 9
EDUCATION B PER PLAN 20 SF 28
EDUCATION B PER PLAN 20 SF 16
PLUMBING CODE CALCULATIONS
OCCUPANCY: BUSINESS - B OCCUPANTS: 10 5 MALE 5 FEMALE
WATER CLOSET LAVATORIES DRINKING
FOUNTAINS
SERVICE SINK
REQUIRED 0.2
MALE FEMALE
0.2 0.125
MALE FEMALE
0.125 0.1 1
OCCUPANCY: EDUCATION OCCUPANTS: 44 22 MALE 22 FEMALE
WATER CLOSET LAVATORIES DRINKING
FOUNTAINS
SERVICE SINK
REQUIRED 0.44
MALE FEMALE
0.44 0.44
MALE FEMALE
0.44 0.44 1
TOTALS 0.64 0.64 0.56 0.56 0.44 1
PROVIDED 2 2 2 1
54 OCC.
DATE DESCRIPTION
07/19/2024 100% DESIGN DEVELOPMENT
12/05/2024 100% CONSTRUCTION DOCUMENTS
SHOWER CURTAIN RODMOUNTED MIRROR AT
LAVATORY
BABY CHANGING STATION
(WALL MOUNTED)
SEAT-COVER
DISPENSER (SURFACE
MOUNTED)
SEAT-COVER
DISPENSER,
SANITARY NAPKIN
DISPOSAL & TOILET
TISSUE DISPENSER
SEAT-COVER
DISPENSER &
TOILET
TISSUE DISPENSER
(308)
SOAP DISPENSER
(SURFACE MOUNTED)
CLOTHES HOOKS
SANITARY NAPKIN
DISPOSAL & TOILET
TISSUE DISPENSER
TOILET TISSUE
DISPENSER
NOTE:
8" MIN. KNEE SPACE BELOW.
THE DEPTH SHALL BE 17" MIN. AND
27" A.F.F. FOR
KNEE CLEARANCE
SANITARY NAPKIN
DISPOSAL
(SURFACE
MOUNTED)
PAPER TOWEL
DISPENSER
(SURFACE
MOUNTED)
TOUCHLESS PAPER
TOWEL DISPENSER
(SEMI-RECESSED)
TOILET PAPER
ROLL HOLDER
WALL
SOAP DISH
TOILET MOUNTING HEIGHT
* MOUNT OPPOSITE WALL
FROM TOILET TISSUE
DISPENSER
MOUNTED MIRRORLAVATORYWATER FOUNTAIN - WHEELCHAIR
ACCESSIBLE
TOWEL/ROBE
HOOKS SURFACE
MOUNTED
FREESTANDING
WASTE
RECEPTACLE
NOTE:
INLET SHALL BE
WITHIN ACCESSIBLE
REACH RANGE
GENERAL NOTES
1. * INDICATES NOTE AND/OR DIMENSION SPECIFIED BY BRAND
STANDARD
2. FOR INFORMATION REGARDING CLEAR FLOOR SPACES REFER TO
SUBSEQUENT A900 SHEETS
3. PROVIDE BLOCKING, OR DIRECT STUD SUPPORT, FOR ALL TOILET
ACCESSORIES.
DOOR AND VISION LIGHTS URINAL
WALL HUNG TYPE
SLIDING SHOWER SPRAY ON
VERTICAL BAR
TOWEL BAR SURFACE
MOUNTED
WATER FOUNTAIN -
STANDING PERSONS
* FIXED SHOWER HEAD
HT 78" - 84"
SHELVES
S H
O W
E R
H E
A D
H E
IG
H
T
M
IN
S T
R A
IG
H
T R
O D
A
T A
D A
S H
O W
E R
S O
N
LY
6'
C U
R V
E D
S H
O W
E R
R O
D
A T
A D
A B
A T
H T
U B
S
6'
T O
T .O
. S E
A T
M A
X
4'
M A
X T
O T
.O . T
O W
E L
B A
R
T O
R E
F
LE
C T
IV
E
S U
R F
A C
E
2'
1"
M A
X
6'
M
IN
VARIES
T O
R E
F
LE
C T
IV
E
S U
R F
A C
E
3'
M A
X
6'
M
IN
VARIES
2'
0"
M A
X
M
IN
M
IN
3" M
A X
T O
S P
O U
T
3'
M A
X 4"
M
IN
. W A
T E
R S
T R
E A
M
A B
S O
LU
T
E
B .O
. V
IS
IO
N
L
IG
H T
3'
4'
M A
X A
.F .F
A .F
.F
1'
M
IN
R E
A C
H R
A N
G E
F R
O N
T
S
ID
E
4'
M A
X A
.F .F
A .F
.F
1'
M
IN
R E
A C
H R
A N
G E
F R
O N
T
S
ID
E 7" - 9"
(1 5"
M
IN
8"
M A
X
1'
1"
7" - 9"
(1 5"
M
IN
8"
M A
X
1'
(1 5"
M
IN
8"
M A
X
1'
7" - 9"
3'
/2
3'
/2
4'
M A
X
T O
A C
T
IV
A T
IO
N
S E
N S
O R
4'
M A
X
T O
T O
P O
F O
P E
R A
B
LE
P A
R T
4'
M A
X
2'
4'
M A
X . T
O T
.O . H
O O
K
4'
M A
X
M
IN
8" M
A X
T .O
. S H
E
LF
W O
R K
S U
R F
A C
E H
E
IG
H T
M A
X
4'
M A
X
M
IN
8" M
A X
2'
CORNER
SOAP DISH
FIG. 604.5.2
REAR WALL GRAB BAR FOR WATER CLOSET
INCLUDES:
LIGHT SWITCHES, ELECTRICAL OUTLETS, ENVIRONMENTAL CONTROLS.
EXCLUDES:
CIRCUIT BREAKERS, APPLIANCE CONTROLS, AND OUTLETS DEDICATED
FOR SPECIAL APPLICATIONS.
O B
S T
R U
C T
E D
H
IG
H
F O
R W
A R
D
E
A C
H A
N S
I
8.
2.
O B
S T
R U
C T
E D
H
IG
H S
ID
A
C H
A N
S I 3
.3
.2
M A
X . A
.F .F
M A
X . A
.F .F
M A
X . A
.F .F
1003.11.2.4.6 FLUSH CONTROLS.
HAND OPERATED FLUSH CONTROLS SHALL COMPLY WITH
SECTION 1003.9. FLUSH CONTROLS SHALL BE LOCATED ON
THE OPEN SIDE OF THE WATER CLOSET.
NOTE:
ACCESSIBLE WATER CLOSETS MUST COMPLY WITH
ICC/ANSI A117.1-2017 SECTIONS 603 & 604.
DESIGN BASED UPON 2017 ANSI REQUIREMENTS.
ALL DIMENSIONS ARE TO FACE OF FINISH UNLESS
NOTED OTHERWISE.
604.2 - WATER
CLOSET LOCATION
NOTE:
602.2 PROVIDE KNEE SPACE BELOW DRINKING
FOUNTAIN
U N
O B
S T
R U
C T
D
F
O R
W A
R D
/S
ID
E R
E A
C H
A
N S
I 3
.2 .1
/3
.3 .1
M A
X
M
IN
3" M
A X
M A
X
K N
E E
C
LE
A R
A N
C E
M
IN
9" M
IN 27
M
IN
' M
IN
M A
X
25" MAX. DEPTH
17" MIN. DEPTH
KNEE CLEARANCE
8" MIN.
11" MIN. TOE CLEARANCE
6" MAX.
4'
M
IN
5' - 0" MIN
(2 4"
A
LL
U
N
IT
S
M
IN
1'
M
IN1' - 0" MAX3' - 6" MIN
ANSI MOUNTING HEIGHTS
TRANSFER-TYPE SHOWER COMPARTMENT
ANSI DRINKING FOUNTAIN
NOTE:
REACH DIMENSIONS TO CONFORM TO REQUIREMENTS, DIMENSIONS, AND
LIMITATIONS SET FORTH IN ANSI A117.1-2017, SECTION 308 AND 309 ALONG WITH
MANUFACTURERS ADA STANDARD MOUNTING HEIGHTS.
COORDINATE WITH ARCHITECT PRIOR TO ANY SWITCH/OUTLET INSTALLATION.
MAINTAIN 30" X 48" CLEAR FLOOR SPACE PERPENDICULAR TO WALL WHERE
CONTROL IS LOCATED FOR A FORWARD REACH TO CONTROL.
FIG. 604.2 ACCESSIBLE WATER CLOSET
FIG. 604.3 SIZE OF CLEARANCE FOR WATER CLOSET
1' - 0" MIN2' - 0" MIN
(A
N S
I)
3' - 0" MIN
4' - 6" MIN
39"- 3' - 5"
FIG. 604.5.1
SIDE WALL GRAB BAR FOR WATER CLOSET
18" (UFAS)
16" - 18"
604.3 CLEARANCE.
OTHER FIXTURES NOT ALLOWED WITHIN THIS AREA
2'
M
IN
5' - 0" MIN
0' - 6" MAX
1'
M
IN
E N
D W
A
LL
E N
D W
A
LL
BACK WALL
3"
0'
1/ 4"
0'
M A
X
0' - 2 1/2" MAX
0'
/2
M A
X
0'
M A
X
15" - 16"
2'
M
IN
2' - 3" MAX
3'
M
IN
4'
M A
X
BACK WALLS
E
A T
W A
LL
C O
N T
R O
L W
A
LL
BACK WALL
3' - 0" MIN
3'
M
IN
3'
M
IN
4' - 0" MIN
1' - 4" MIN
1' - 3" MAX
CONTROL
WALL
0'
M
IN
2'
M
IN
4'
M A
X
ROLL-IN SHOWER
BACK
WALL
0'
M
IN
2'
M
IN
0'
M A
X
1' - 6" MINREINFORCEMENT READY FOR
FUTURE GRAB BAR INSTALLATION
3'
M
IN
CONTROL AND HANDSHOWER LOCATION
608.5 HANDSHOWER
CONTROL AND HANDSHOWER LOCATION
608.5 HANDSHOWER
1'
M A
X 3'
M
IN
S E
A T
H E
IG
H
T
1' - 6"
24" MIN 12" MIN
TRANSFER-TYPE SHOWER COMPARTMENT ROLL-IN SHOWER
ACCESSIBLE LAVATORY
W H
E N
L O
C A
T E
D A
B V
C O
U N
T E
R T
O P
M A
X
1'
M
IN
4'
M A
X
2' - 0" MIN
FIG. 604.7.1(A &B)
DISPENSER OUTLET LOCATION PROTRUDING
ABOVE/BELOW GRAB BAR
3' - 0 1/128" MAX
2' - 0 1/128" MIN.
M
IN
M
IN
0'
/2
42" MAX
1'
M
IN
4'
M A
X
FIG. 604.7.1(C)
DISPENSER OUTLET LOCATION RECESSED
DISPENSER
3' - 0" MAX
2' - 0" MIN.
42" MAX
NOTE:
SOME CONDITIONS DEPICTED HERE MAY NOT EXIST IN THIS PROJECT AND ARE
DRAWN FOR REFERENCE ONLY.
4" M
A X
PROJECT NO.: INITIAL DATE:
DRAWN BY: CHECKED BY:
ARCHITECTURAL WORKSHOP . DENVER, COLORADO
A R
C H
IT
E
C T
U R
A L
W O
R K
S H
O P
, L
LC
. A
LL
R
IG
H T
S R
E S
E R
V E
D
2417mcc JUNE 2024
ZEAP JM
2024-107_MORGAN CC
WRAY CAMPUS T.I.
300 DEXTER ST
WRAY CO, 80758
G-003
ACCESSIBILITY INFORMATION
DATE DESCRIPTION
GENERAL CONTRACTOR NOTES:
1. PERMITS:
IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO SUBMIT FOR BUILDING PERMIT THROUGH THE APPLICABLE JURISDICTION.
THE CONTRACTOR SHALL PAY FOR THE PERMIT. THE CONTRACTOR SHALL HAVE A VALID COMMERCIAL LICENSE AND TO PICK UP THE
PERMIT.
2. DOCUMENTS:
CONTRACTOR AND SUB-CONTRACTORS ARE RESPONSIBLE TO READ AND UNDERSTAND ALL OF THE DRAWINGS AND THE PROJECT
SPECIFICATION BOOK.
3. SITE EXAMINATION:
GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL VISIT AND EXAMINE THE SITE AND BUILDING IN EVERY DETAIL AS IT PERTAINS
TO THE PROJECT PRIOR TO SUBMITTING A BID PROPOSAL.
4. DISCREPANCIES:
ANY DISCREPANCIES DISCOVERED BY THE GENERAL CONTRACTOR OR BY THE SUBCONTRACTORS, BETWEEN DIMENSIONS, OR CONFLICTS UNFORESEEN PREVIOUSLY SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT FOR CLARIFICATION.
5. BUILDING CODE COMPLIANCE:
PERFORM ALL WORK TO COMPLY WITH APPLICABLE BUILDING CODES AND REGULATIONS. FOR BUILDING CONDITIONS THAT ARE NOT CONSTRUCTED TO MEET CURRENT BUILDING CODES, THE GENERAL CONTRACTOR IS TO PROVIDE ALTERNATE PRICING TO BRING ITEMS
INTO CODE COMPLIANCE.
6. HOURS OF CONSTRUCTION:
GENERAL CONTRACTOR (G.C.) IS RESPONSIBLE TO COORDINATE WITH THE BUILDING MANAGER FOR HOURS OF OPERATION, ALLOWABLE CONSTRUCTION TIMES AND CONSTRUCTION ACTIVITIES. THE G.C. SHALL ASSUME ALL RESPONSIBILITY FOR ALL SUB-CONTRACTORS.
7. LONG LEAD ITEMS:
THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR BEING FAMILIAR WITH THE PROJECT SCHEDULE AND DEADLINES, AND FOR ADVISING THE ARCHITECT FOR ALL LONG LEAD ITEMS. ORDER CONFIRMATION SHALL BE SUBMITTED WITH DELIVERY DATES. PROVIDE LEAD TIME ESTIMATES WITH ANY BID PROPOSALS. IT SHALL BE AT THE GENERAL CONTRACTORS EXPENSE IF ANY LONG
LEAD ITEMS ARE DISCOVERED AFTER THE PROJECT BEGINS.
8. CLEAN UP:
CLEANING OF EQUIPMENT SHALL BE LIMITED TO AREAS DESIGNATED BY THE BUILDING MANAGER / OWNER. TRASH SHALL BE REMOVED AND SWEEPING\VACUUMING SHALL BE PROVIDED ON A DAILY AND CONTINUING BASIS THROUGHOUT THE CONSTRUCTION PROCESS. FINAL CLEANING SHALL BE PROVIDED BY THE CONTRACTOR AND INCLUDE WINDOWS, SILLS, WINDOW COVERINGS (BLINDS), CABINETS, LIGHT
FIXTURES, SUPPLY AIR DIFFUSERS AND RETURN AIR GRILLS.
9. DISPOSAL:
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING THE DUMPSTER. THE G.C. SHALL COORDINATE WITH THE APPLICABLE JURISDICTION FOR LOCATION AND ALLOWABLE SIZE. THE G.C. SHALL DISPOSE OF / RECYCLE ALL WASTE IN ACCORDANCE WITH ACCEPTED
STANDARDS OF THE APPLICABLE JURISDICTION.
10. DEMOLITION:
IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE DEMOLITION WITH NEW WORK REQUIREMENTS, COORDINATE COMPLETED EARLY DEMO WORK PERFORMED BY OTHERS WITH MCC PROJECT MANAGER TO ENSURE ALL DEMO IS COMPLETED.
11. PROTECTION OF EXISTING ITEMS:
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO PROTECT ALL EXISTING CONSTRUCTION ON AND OFF SITE, AND SHALL BE HELD RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE CAUSED BY GENERAL CONTRACTOR OR ANY OF ITS SUBCONTRACTORS.
12. WORK PERFORMED UNDER SEPARATE CONTRACT:
THE GENERAL CONTRACTOR IS TO VERIFY WITH THE BUILDING MANAGER / OWNER, IF ANY WORK IS TO BE PERFORMED UNDER A SEPARATE
CONTRACT.
13. LIGHTING CONTROLS: IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR AND ALL ASSOCIATED SUB CONTRACTORS TO UNDERSTAND THE EXISTING SYSTEM AND ITS CAPACITY TO SUPPORT THE PROJECT AS SHOWN IN THESE CONSTRUCTION DOCUMENTS, RE:
ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.
14. FIRE WALL PENETRATIONS:
ALL PENETRATIONS THROUGH FIRE RESISTIVE CONSTRUCTION SHALL BE SEALED WITH AN
APPROVED UL FIRE ASSEMBLY TO MAINTAIN THE REQUIRED FIRE RATING.
15. WORK PERFORMED UNDER SEPARATE CONTRACT: THE GENERAL CONTRACTOR IS TO VERIFY WITH THE BUILDING MANAGER, IF ANY WORK
IS TO BE PERFORMED UNDER A SEPARATE CONTRACT.
16. CONTRACTOR SHALL BE RESPONSIBLE FOR REVIEWING ALL DRAWINGS AND SPECIFICATIONS ALONG WITH SITE CONDITIONS TO ENSURE THE PROJECT BID IS COMPREHENSIVE. DURING THE BIDDER ADDENDUM QUESTION PHASE, CONTRACTOR SHALL NOTIFY ARCHITECT AND MCC PROJECT MANAGER OF ANY ADDITIONAL SCOPE THAT MAY BE REQUIRED TO PROVIDE A COMPREHENSIVE PROJECT.
17. GENERAL CONTRACTOR AND ELECTRICAL SUBCONTRACTOR SHALL BE RESPONSIBLE FOR TRACING ALL EXISTING ELECTRICAL CIRCUITS ASSOCIATED WITH THIS PROJECT BACK TO THEIR PANEL(S) PRIOR TO TURNING OFF ANY CIRCUITS TO COMPLETE NEW WORK. PROVIDE
UPDATED PANEL SCHEDULES AS REQUIRED PER ELECTRICAL DRAWINGS.
A.F.F A.C.T A.C.
ADJ.
AL
ALT
L
ANOD
A.D.
B.M.
BIT
BLK
BD
BLDG
B.B.
B.U.R.
C.I.P.
CPT
CLK
C.B.
CLG
CTR
C.T.
CLR
COL
CONC
C.M.U.
CONST
CJ
CONT
CONTR
CORR.
C.U.H.
DET/DTL
DIA
DIM
DR
DN
D.S.
DWG
D.F.
ELEC
E.W.C.
ELEV
EQ
EQUIP
EIFS
EXH.
EXIST
E.J.
EXT
EPDM
F.B.
FT
FIN
F.F.
F.A.P.
F.E.
F.E.C.
FL
F.D.
FTG
FDN
ABOVE FINISH FLOOR
ACOUSTIC CEILING TILES
AIR CONDITIONING
ADJUSTABLE
ALUMINUM
ALTERNATE
ANGLE
ANODIZED
AREA DRAIN
AT
BENCH MARK
BITUMINOUS
BLOCK
BOARD
BUILDING
BULLETIN BOARD
BUILT UP ROOF
CAST-IN-PLACE-CONCRETE
CARPET
CAULKING
CHALK BOARD
CEILING
CENTER
CERAMIC TILE
CLEAR
COLUMN
CONCRETE
CONCRETE MASONRY UNIT
CONSTRUCTION
CONTROL JOINT
CONTINUOUS/CONTINUE
CONTRACTOR
CORRIDOR
CABINET UNIT HEATER
DETAIL
DIAMETER
DIMENSIONS
DOOR
DOWN
DOWN SPOUT
DRAWING
DRINKING FOUNTAIN
ELECTRICAL
ELECTRIC WATER COOLER
ELEVATION
EQUAL
EQUIPMENT
EXT. INSUL. & FINISH SYSTEM
EXHAUST
EXISTING
EXPANSION JOINT
EXTERIOR
ETHYLENE PROPYLENE DIENE MONOMER
FACE BRICK
FEET
FINISH
FINISH FLOOR
FIRE ALARM PANEL
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
FLOOR/FLOOR LINE
FLOOR DRAIN
FOOTING
FOUNDATION
GALV.
GA
GEN
G.C.
GLAM
G.B.
GR
GYP. BD
HWD
HT
H.P.
H.M.
IN
I.D.
I.G.
INSUL
INT.
INV.
JAN
JT
KIT
LAB
LAM
LAV
LGTH
LF
L.S.D.
MH
MFR
M.O.
MATL
MAX
MECH
MTL/MET
MICR
MIN
MISC
MOD
NONCOM
N.I.C.
N.T.S.
NO.
OFF
O.C.
OPG
OPH
O.D.
PNT
PTN
PL
PLT
P&H
PLWD
P.I.P.
PC
PFB
PREFIN
P.W.B.
PRELIN
P.L.
GALVANIZED
GAUGE
GENERAL
GENERAL CONTRACTOR
GLUE LAMINATED WOOD BEAM
GRAB BAR
GRADE
GYPSUM BOARD
HARD WOOD
HEIGHT
HIGH POINT/HIGH PRESSURE
HOLLOW METAL
INCH
INSIDE DIAMETER
INSULATING GLASS
INSULATION
INTERIOR
INVERT
JANITOR
JOINT
KITCHEN
LABORATORY
LAMINATE
LAVATORY
LENGTH
LINEAL FOOT
LIQUID SOAP DISPENSER
MANHOLE
MANUFACTURER
MASONRY OPENING
MATERIAL
MAXIMUM
MECHANICAL
METAL
MICROWAVE
MINIMUM
MISCELLANEOUS
MODULE
NON-COMBUSTIBLE
NOT IN CONTRACT
NOT TO SCALE
NUMBER
OFFICE
ON CENTER
OPENING
OPPOSITE HAND
OUTSIDE DIAMETER
PAINTED/PAINT
PARTITION
PLASTER
PLATE
PLUMBING AND HEATING
PLYWOOD
POURED IN PLACE CONCRETE
PRECAST
PREFABRICATED
PREFINISHED
PREFINISHED WALL BOARD
PRELIMINARY
PROPERTY LINE
RAD
R.W.R.
RECP
REC
REF
REINF
REQD
RESIL
R.D.
RM
R.O.
SAN
SCH
SECT.
SHT
SIM
S.D.
S.C.
SPR
SF
S.S.
STD
STL
STO
STR
SUSP
SYM
SYS.
T.B.
TEL
THK
THRES
TOIL
T.T.D.
T&G T.O.C.
T.O.D.
T.O.M.
T.O.S.
TYP
T.D.R.
UC
UG
UNFIN
V.B.
VENT
V.I.F.
VERT
V.C.T.
W.C.
WP
W.S.
WT
WWF
W/ W/O
WD
RADIUS
RAIN WATER RECEIVER
RECEPTACLE
RECESS
REFERENCE
REINFORCE/REINFORCING
REQUIRED
RESILIENT
ROOF DRAIN
ROOM
ROUGH OPENING
SANITARY
SCHEDULE
SECTION
SHEET
SIMILAR
SMOKE DETECTOR
SOLID CORE
SPRINKLER
SQUARE FOOT
STAINLESS STEEL
STANDARD
STEEL
STORAGE
STRUCTURAL
SUSPENDED
SYMMETRIC
SYSTEM
TACK BOARD
TELEPHONE
THICK
THRESHOLD
TOILET
TOILET TISSUE DISPENSER
TONGUE & GROOVE
TOP OF CONCRETE
TOP OF DECK
TOP OF MASONRY
TOP OF STEEL
TYPICAL
TOWEL DISPENSER & RECEPTACLE
UNDER COUNTER
UNDERGROUND
UNFINISHED
VAPOR BARRIER
VENTILATING
VERIFY IN FIELD
VERTICAL
VINYL COMPOSITION TILE
WATER CLOSET
WATERPROOFING
WEATHER STRIP
WEIGHT
WELDED WIRE FABRIC
WITH
WITHOUT
WOOD
ABBREVIATIONS:
COLUMN GRID
DETAIL/WALL SECTION
DETAIL 1 ON SHEET A101
EXTERIOR ELEVATION
DRAWING 1 ON SHEET A101
BUILDING SECTION
DRAWING 1 ON SHEET A101
DETAIL BUBBLE
DETAIL 1 ON SHEET A101
INTERIOR ELEVATION
DRAWING 1 ON SHEET A7.1
DRAWING TITLE AND NUMBER
NORTH ARROW
ROOM NAME AND NUMBER
ELEVATION MARKER
DOOR NUMBER
WINDOW TYPE
CENTER LINE
OBJECTS ABOVE
SOFFITS, CABINETS,
HIGH WINDOWS
HIDDEN OBJECTS
KEYNOTE
ROOM FINISHES
A101
SIM
A101
A101
SIM
TITLE
SCALE
ROOM NAME
1t
D
SYMBOLS LEGEND:
A101
X-1 X-1
X-1X-1
WALL WAINSCOTING
WALL BASE FLOOR
A101
Ref
R e f
R e f
Ref
LIFESAFETY NOTES:
THE FOLLOWING NOTES SHALL BE A CONTRACTUALLY BINDING AND APPLY TO ALL DISCIPLINES. IT IS THE CONTRACTORS OBLIGATION TO ENSURE ALL WORK AND ALL SUB CONTRACTORS WORK BE PERFORMED IN
COMPLIANCE WITH THE FOLLOWING NOTES IN ADDITION TO THE CONSTRUCTION
DOCUMENTS AND PROJECT SPECIFICATIONS.
1. HOT WORK DURING CONSTRUCTION:
THE CONTRACTOR SHALL ENSURE THAT ANY HOT WORK ACTIVITIES DURING CONSTRUCTION, E.G., USING HEAT GUNS, SOLDERING, BRAZING, WELDING, GRINDING, POWDER DRIVEN STUDS, METAL CUTTING USING POWER TOOLS OR OTHER ACTIVITIES INVOLVING FLAMES OR SPARKS ARE PRECEDED BY OBTAINING AN
APPROVED HOT WORK PERMIT.
2. ACCESS AND EGRESS OBSTRUCTIONS:
THE CONTRACTOR SHALL CONFIRM THAT THE PROJECT STAGING AREA AND CONSTRUCTION ACTIVITIES DO NOT CAUSE THE OBSTRUCTION OF PATHS OF EGRESS INSIDE THE BUILDING, BLOCK EXIT DISCHARGE FROM
THE BUILDING OR IMPEDE EMERGENCY VEHICLE ACCESS TO THE AREA.
3. DUST/FUME GENERATION:
IF THE CONSTRUCTION ACTIVITIES GENERATE DUST OR FUMES INSIDE THE BUILDING, NECESSARY MEASURES ARE TO BE TAKEN TO PREVENT THE NUISANCE ACTUATION OF ANY NEARBY SMOKE OR DUCT
DETECTORS. THE CONTRACTOR SHALL CONTACT THE FIRE SYSTEMS GROUP TO TAKE NECESSARY
ACTIONS.
4. PENETRATIONS THROUGH FIRE RATED ASSEMBLIES:
THE CONTRACTOR SHALL ENSURE THAT ANY PENETRATIONS THROUGH FIRE RATED ASSEMBLIES (FLOORS, PARTITIONS, WALLS, ETC.) SHALL BE SEALED WITH AN APPROVED UL FIRE ASSEMBLY TO MAINTAIN THE
REQUIRED FIRE RATING.
5. PEDESTRIAN PROTECTION:
THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE ANY NECESSARY PEDESTRIAN PROTECTION
MEASURES DURING CONSTRUCTION.
WORK UNDER SEPARATE CONTRACT:
1. IT AND VIDEO\TECHNOLOGY:
THE CONTRACTOR IS RESPONSIBLE TO WORK WITH AND PROVIDE ALL REASONABLE ACCOMMODATIONS TO
ALLOW THE IT AND VIDEO CONTRACTOR TO COMPLETE HIS WORK.
2. THE ELECTRICAL CONTRACTOR SHALL INSTALL ALL JUNCTION BOXES AND 1" CONDUIT TO ABOVE CEILING
GRID / BELOW RAISED FLOORS.
3. FIRE ALARM \ SECURITY SYSTEMS:
CONTRACTOR SHALL BE RESPONSIBLE TO CONTRACT WITH AND COORDINATE THE REQUIRED WORK FOR FIRE ALARM AND SECURITY SYSTEMS. THE BUILDING REQUIRES THE USE OF THE FOLLOWING FIRMS FOR
THE SCOPE OF WORK.
FIRE ALARM: PER SPECIFICATION
SECURITY\CARD READER: PER SPECIFICATION
4. BUILDING OWNER AND MCC PROJECT MANAGER SHALL PROVIDE GENERAL CONTRACTOR WITH REQUIRED INFORMATION FOR SUITE, WAY-FINDING, AND OFFICE SIGNAGE FOR THE PROJECT PER BUILDING STANDARDS. GENERAL CONTRACTOR TO PROVIDE SHOP DRAWINGS OR REVIEW / APPROVAL PRIOR TO
INSTALLATION.
5. FURNITURE:
THE FURNITURE MANUFACTURER SHALL BE RESPONSIBLE FOR ASSEMBLY AND INSTALLATION OF ALL FURNITURE SYSTEMS. FURNITURE DELIVERY SHALL BE COORDINATED WITH GENERAL CONTRACTOR. THE GENERAL CONTRACTOR SHALL HAVE THE ELECTRICAL CONTRACTOR BE AVAILABLE TO CONNECT THE ELECTRICAL HOOKUP FOR ALL THE WORK STATIONS AT THE SCHEDULED TIME. SEE FURNITURE PLAN FOR
ADDITIONAL INFORMATION.
GENERAL ACCESSIBILITY NOTES:
1. FLOOR SURFACES SHALL BE SLIP-RESISTANT.
2. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED 1/2" IN HEIGHT. LEVEL CHANGES NOT EXCEEDING 1/4" MAY BE VERTICAL. BEVEL OTHERS WITH A SLOPE NO GREATER THAN 1:2.
3. FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS. LEVER OPERATED, PUSH TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. SELF CLOSING ARE ALLOWED IF
THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS.
ADD ALTERNATE LIST:
ADD ALTERNATE #1: REMOVE THE EXISTING FAUX CMU PANELING AND EXISTING METAL PANELING. THEN INSTALL NEW METAL PANEL SYSTEM ON THE WEST, NORTH, AND SOUTH SIDES OF THE BUILDING. REPLACE THE EXISTING CAN LIGHTS IN THE SOFFITS WITH NEW LINEAR RECESSED FIXTURES. INSTALL A NEW WINDOW OVER DOOR 011.
ADD ALTERNATE #2: REMOVE THE EXISTING FAUX CMU PANELING AND EXISTING METAL PANELING. THEN INSTALL
NEW METAL PANEL SYSTEM ON THE EAST SIDE OF THE BUILDING.
PROJECT NO.: INITIAL DATE:
DRAWN BY: CHECKED BY:
ARCHITECTURAL WORKSHOP . DENVER, COLORADO
A R
C H
IT
E
C T
U R
A L
W O
R K
S H
O P
, L
LC
. A
LL
R
IG
H T
S R
E S
E R
V E
D
2417mcc JUNE 2024
ZEAP JM
2024-107_MORGAN CC
WRAY CAMPUS T.I.
300 DEXTER ST
WRAY CO, 80758
G-004
PROJECT INFORMATION
DATE DESCRIPTION
300 DEXTER ST WRAY CO, 80758
EXISTING TRASH
ENCLOSURE
U .S
. H W
Y
D
E X
T E
R S
T R
E E
T
W 3RD ST
D1
D4
D5
EXISTING CONCRETE
SIDEWALK
4' - 0"
18'-0"
ALLEY
D7
D8
D2
TYP.
D3
TYP.
D3
D6
D9 D10
D11
D12D12
D13
DEMO SITE PLAN KEYNOTES:
DEMO AND DISPOSE OF THE ENTIRETY OF THE EXISTING
CANOPY.
DEMO AND DISPOSE OF THE REQUIRED EXTENTS OF THE
EXISTING CONCRETE SLAB BENEATH THE CANOPY.
DEMO AND DISPOSE OF THE EXISTING CONCRETE BOLLARDS.
DEMO AND DISPOSE OF EXISTING VAN ACCESSIBLE SIGNAGE,
REPAIR ADJACENT FINISHES AS REQUIRED.
DEMO AND DISPOSE OF EXISTING FIRE EXTINGUISHER CABINET,
PATCH AND REPAIR ADJACENT SURFACES AS REQUIRED.
DEMO AND DISPOSE OF EXISTING SIGN IN ITS ENTIRETY.
EXISTING SIGN AND STRUCTURE TO REMAIN, PROTECT DURING
CONSTRUCTION.
DEMO AND DISPOSE OF EXISTING RTU UNIT AND CURB, PATCH
AND REPAIR ROOF AS REQUIRED TO MATCH EXISTING TO
PROVIDE A WATER TIGHT ASSEMBLY. RE: MEP DRAWINGS FOR
ADDITIONAL INFORMATION.
DEMO AND DISPOSE OF EXISTING CONCRETE BLOCK BASE TO
EXISTING CONCRETE SLAB, PATCH AND REPAIR EXISTING
CONCRETE SLAB AS REQUIRED.
PROVIDE BLANK COVER PLATE @ J-BOX AND REMOVE
CONDUCTORS BACK TO SOURCE.
DEMO AND DISPOSE OF DENTED DOWNSPOUT AND REPLACE
WITH LIKE FOR LIKE AND PAINT AS NOTED ON SHEET A-201.
DEMO AND DISPOSE OF EXHUAST FAN PREVIOUSLY
INTERLOCKED WITH REFRIGERANT DETECTION SYSTEM. PATCH
BACK WITH SIMILAR MATERIALS AS REQUIRED. RE: MEP
DRAWINGS FOR ADDITIONAL INFORMATION.
DEMO AND DISPOSE OF THE NOTED EXTENTS OF THE SLOPED
CONCRETE ENTRY SIDEWALK.
D1
D2
D3
D4
D5
D6
D7
D8
D9
D10
D11
D12
D13
PROPERTY LINE
EXISTING LAMP POST
NEW LAMP POST
DEMOLITION WORK
SITE PLAN LEGEND:
300 DEXTER ST WRAY CO, 80758
EXISTING TRASH
ENCLOSURE
U .S
. H W
Y
D
E X
T E
R S
T R
E E
T
W 3RD ST
EXISTING CONCRETE
SIDEWALK
A-201
A-201
A-201
A-201
4' - 0"
H.C.
VAN
H.C. 18'-0"
ALLEY
4 4
9' - 0" TYP.
T Y
P
27' - 6"
9' - 0" 4' - 6"4' - 6"
9' - 2"
27' - 6"
5'
5'
9'
" 18' - 0"
V.I.F.
4' - 6"
1" / 12"
1" / 10"
1" / 10"
MAX 2% SLOPE AT
ACCESSIBLE
PARKING SPACES
AND ADJACENT
ACCESS AISLES
MAX 2% SLOPE
AT ACCESSIBLE
PARKING SPACES
AND ADJACENT
ACCESS AISLES
SITE PLAN KEYNOTES:
PATCH WITH ASPHALT WHERE CONCRETE SLAB HAS BEEN
DAMAGED.
APPLY A SEAL COAT TO THE ENTIRETY OF THE EXISTING
CONCRETE SLAB AND NEW ASPHALT.
INSTALL NEW LAMP POSTS, RE: MEP DRAWINGS FOR ADDITIONAL
INFORMATION.
PARKING LOT TO BE STRIPED ACCORDING TO SITE PLAN.
INSTALL NEW WALL MOUNTED EXTERIOR DOWNLIGHT, RE: MEP
DRAWINGS FOR ADDITIONAL INFORMATION.
REPAIR EXISTING WAINSCOT WHERE IT HAS SPRUNG AWAY
FROM METAL PANEL ABOVE AND SEAL JOINT.
LOCATE THE EXISTING ROOF LEAK AND REPAIR LEAK AND
EXTENTS OF WATER DAMAGE.
PAINT EXISTING METAL SIGNAGE FRAME P-1.
INSTALL NEW STEEL BOLLARDS ENCASED IN CONCRETE
POUR NEW CONCRETE SLAB AT NOTED EXTENTS WITH A MAX 2%
SLOPW. ELEVATION OF SLAB TO ALIGN WITH EXISTING
SIDEWALK ELEVATION.
POUR NEW BUILT-UP CONCRETE CURB RAMP WITH A SLOPE OF
1:12 AND SIDE FLARES WITH A SLOPE OF 1:10.
INSTALL NEW POLE MOUNTED ACCESSIBLE AND VAN
ACCESSIBLE PARKING SIGNAGE AS SHOWN IN DETAIL 3/AS-101.
M
IN
VAN ACCESSIBLE
PARKING SIGNAGE
ACCESSIBLE PARKING
SIGNAGE
M
IN
PROJECT NO.: INITIAL DATE:
DRAWN BY: CHECKED BY:
ARCHITECTURAL WORKSHOP . DENVER, COLORADO
A R
C H
IT
E
C T
U R
A L
W O
R K
S H
O P
, L
LC
. A
LL
R
IG
H T
S R
E S
E R
V E
D
2417mcc JUNE 2024
ZEAP JM
2024-107_MORGAN CC
WRAY CAMPUS T.I.
300 DEXTER ST
WRAY CO, 80758
AS-101
ARCHITECTURAL SITE PLAN
1/16" = 1'-0"1 ARCHITECTURAL DEMO SITE PLAN
1/16" = 1'-0"2 ARCHITECTURAL SITE PLAN
DATE DESCRIPTION
07/19/2024 100% DESIGN DEVELOPMENT
12/05/2024 100% CONSTRUCTION DOCUMENTS
02/24/2025 ADDENDUM #1 - CODE REVIEW
1/2" = 1'-0"3 ACCESSIBLE PARKING SIGNAGE DETAIL
TV
GENERAL DEMO NOTES:
1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. ANY
DISCREPANCIES IN DRAWINGS AND/OR EXISTING CONDITIONS
SHOULD BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE
ARCHITECT FOR CLARIFICATION.
2. THE ARCHITECT DISCLAIMS ANY RESPONSIBILITIES AND/OR
KNOWLEDGE OF ASBESTOS . THE OWNER ACCEPTS ALL
RESPONSIBILITY FOR REMOVAL AND DISPOSAL OF ASBESTOS
IF DISCOVERED. ANY IMPACT OF ASBESTOS CONTAINING
BUILDING MATERIALS MUST BE COORDINATED.
3. ALL WORK SHALL BE IN COMPLIANCE WITH LOCAL AUTHORITY
HAVING JURISDICTION AND INTERNATIONAL BUILDING CODE
2021.
4. ALL WORK SHALL BE IN COMPLIANCE WITH THE
CONSTRUCTION SPECIFICATION MANUAL WHICH IS PART OF
THE PROJECT DOCUMENTS.
5. ALL ABANDONED WIRING, CONDUITS OR MISC. MEP MUST BE
REMOVED.
6. ALL DEMOLITION AND DISPOSAL MUST BE DONE TO MEET ALL
CODES AND LAWS FOR PROPER DISPOSAL.
7. ALL RETURN AIR DUCTS MUST BE FILTERED DURING DEMO
AND CONSTRUCTION TO PREVENT DEBRIS FROM ENTERING
HVAC SYSTEM.
DEMO PLAN KEYNOTES:
DEMO AND DISPOSE OF EXISTING REFRIGERATOR SHELVING,
DOORS, AND INSULATED PANELS IN THEIR ENTIRETY, PATCH
AND REPAIR ADJACENT SURFACES AS REQUIRED.
DEMO AND DISPOSE OF EXISTING VCT FLOORING AND RUBBER
WALL BASE, PATCH AND REPAIR ADJACENT SURFACES AS
REQUIRED.
DEMO AND DISPOSE OF EXISTING WOOD WALL PANELING / TRIM,
PATCH AND REPAIR ADJACENT SURFACES AS REQUIRED.
DEMO AND DISPOSE OF EXISTING RAISED FLOORING IN ITS
ENTIRETY.
DEMO AND DISPOSE OF EXISTING CASEWORK, COUNTERTOPS
PLUMBING FIXTURES, POWER / DATA AND APPLIANCES, RE: MEP
DRAWINGS FOR ADDITIONAL INFORMATION.
DEMO AND DISPOSE OF EXISTING FRP PANELING AND ANY
ADJACENT RUBBER WALL BASE, PATCH AND REPAIR ADJACENT
SURFACES AS REQUIRED.
DEMO AND DISPOSE OF EXISTING ELECTRICAL FLOOR OUTLETS,
FILL CORES WITH GROUT, RE: MEP DRAWINGS FOR ADDITIONAL
INFORMATION.
D1
D2
D3
D4
D5
D6
D7
DEMO AND DISPOSE OF EXISTING SLAB ON GRADE CONCRETE
FLOOR AS REQUIRED TO DEMO EXISTING PLUMBING LINES AND
ROUTE NEW PLUMBING, RE: MEP DRAWINGS FOR ADDITIONAL
INFORMATION.
REMOVE AND SALVAGE EXISTING RESTROOM LAVATORY AND
MIRROR FOR REUSE IN NEW CONSTRUCTION, RE: FLOOR PLAN
AND MEP DRAWINGS FOR ADDITIONAL INFORMATION.
REMOVE AND SALVAGE EXISTING GRAB BARS AND TOILET
PAPER DISPENSER FOR REUSE IN NEW CONSTRUCTION, RE:
FLOOR PLAN FOR ADDITIONAL INFORMATION.
DEMO AND DISPOSE OF EXISTING BABY CHANGING TABLE,
PAPER TOWEL DISPENSER, AND WALL MOUNTED TRASH
RECEPTACLE.
DEMO AND DISPOSE OF EXISTING MOP SINK IN ITS ENTIRETY,RE:
MEP DRAWINGS FOR ADDITIONAL INFORMATION.
DEMO AND DISPOSE OF EXISTING WALL MOUNTED SHELVING IN
ITS ENTIRETY, PATCH AND REPAIR ADJACENT SURFACES AS
REQUIRED.
D8
D9
D10
D11
D14
D15
D16
D17
D18
D19
DEMO AND DISPOSE OF EXISTING WALL MOUNTED SINK, PATCH
AND REPAIR ADJACENT SURFACES AS REQUIRED. RE: MEP
DRAWINGS FOR ADDITIONAL INFORMATION.
DEMO AND DISPOSE OF NOTED PORTION OF EXISTING WALL,
PREP FOR NEW OPENING, RE: FLOOR PLAN
EXISTING COLUMN TO REMAIN, PROTECT DURING
CONSTRUCTION, PATCH AND REPAIR DRYWALL AS REQUIRED
FOR NEW FINISHES.
DEMO AND DISPOSE OF EXISTING FAILED IGU, PREP ALUMINUM
STOREFRONT FOR NEW IGU.
REMOVE EXISTING FILM AND STICKERS FROM EXISTING
ALUMINUM STOREFRONT GLAZING.
DEMO AND DISPOSE OF EXISTING DOOR HARDWARE. EXISTING
DOOR, DOOR FRAMES, AND EXISTING DOOR HINGES TO REMAIN
PROTECT DURING CONSTRUCTION.
DEMO AND DISPOSE OF EXISTING DOOR, DOOR FRAME, AND
DOOR HARDWARE IN ITS ENTIRETY.
D21
D22
DEMO AND DISPOSE OF EXISTING WATER HEATER, AND
ADJACENT CASEWORK IN ITS ENTIRETY, RE: MEP DRAWINGS
FOR ADDITIONAL INFORMATION.
DEMO AND DISPOSE OF EXISTING COMMERCIAL SHELVING
UNITS.
DEMO AND DISPOSE OF EXISTING 3-BAY SINK & FLOOR SINK IN
THEIR ENTIRETY, RE: MEP DRAWINGS FOR ADDITIONAL
INFORMATION.
DEMO AND DISPOSE OF EXISTING FLOOR DRAIN, RE: MEP
DRAWINGS FOR ADDITIONAL INFORMATION.
D12
D13
D20
D23
D24
001A
CASHIER
001B
SALES
COOLER
STORAGE /
UTILITY
001C
VESTIBULE
UNISEX
RESTROOM
UNISEX
RESTROOM
D1
D2
D2
D2
D4
D5
D5
D6
D6
D6 D3
D6
D7D7
D8
D8
D8
D9
D9
D10D11
D10D11
D12
D23
D13
D14
D17
D18 D18 D18D18
D19
D19
D19
D20
D22
D22
D21
D17D17D17D17
D16 D16
D2
D2
D15
D19
D24
EXISTING DOOR TO REMAIN
DEMO PLAN LEGEND:
EXISTING WALL TO REMAIN
DEMOLITION WORK
EXISTING DOOR TO BE DEMOED
EX
EXISTING WALL TO BE DEMOED
PROJECT NO.: INITIAL DATE:
DRAWN BY: CHECKED BY:
ARCHITECTURAL WORKSHOP . DENVER, COLORADO
A R
C H
IT
E
C T
U R
A L
W O
R K
S H
O P
, L
LC
. A
LL
R
IG
H T
S R
E S
E R
V E
D
2417mcc JUNE 2024
ZEAP JM
2024-107_MORGAN CC
WRAY CAMPUS T.I.
300 DEXTER ST
WRAY CO, 80758
AD-101
DEMO PLAN
1/4" = 1'-0"1 DEMO PLAN
DATE DESCRIPTION
D1
D1
D2
D2
D2
D3
D3
D3
D3
D3
D5
D5
D4
D6
D3
TYP.
D7
TYP.
D7
001A
CASHIER
001B
SALES
COOLER
STORAGE /
UTILITY
001C
VESTIBULE
UNISEX
RESTROOM
UNISEX
RESTROOM
ACT CEILING
9' - 7" A.F.F.
INSULATED PANELS
7' - 8" A.F.F.
ACT CEILING
9' - 7" A.F.F.
EX GYP. BD.
8' - 0" A.F.F.
EX GYP. BD.
8' - 0" A.F.F.
DEMO CEILING PLAN
KEYNOTES:
MODIFY EXISTING ACT CEILING GRID AND LAY-IN CEILING TILES
WHERE EXISTING WALL IS BEING MOVED, RE: RCP PLAN AND
MEP DRAWINGS FOR ADDITIONAL INFORMATION.
EXISTING ACT CEILING GRID AND LAY-IN CEILING TILES TO
REMAIN, PROTECT DURING CONSTRUCTION.
DEMO AND DISPOSE OF EXISTING LIGHT FIXTURES, RE: MEP
DRAWINGS FOR ADDITIONAL INFORMATION.
DEMO AND DISPOSE OF EXISTING SECURITY CAMERAS.
EXISTING GYP. BD. CEILING TO REMAIN PROTECT DURING
CONSTRUCTION, PATCH AND REPAIR AS REQUIRED.
DEMO AND DISPOSE OF EXISTING CEILING MOUNTED INSULATED
PANELS.
DEMO AND DISPOSE OF EXISTING LAMPING IN EXISTING SOFFIT
LIGHTS, RE: MEP DRAWINGS FOR ADDITIONAL INFORMATION.
D1
D2
D3
D4
D5
D6
D7
DEMO CEILING PLAN LEGEND
EXISTING WALL
DEMOLISHED (CUT THROUGH)
DEMOLISHED (SURFACE AREA)
EXISTING ACT CEILING TO REMAIN
EXISTING TROFFER LIGHT TO BE DEMOED
EXISTING WALL TO BE DEMOED
GENERAL DEMO NOTES:
1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. ANY
DISCREPANCIES IN DRAWINGS AND/OR EXISTING CONDITIONS
SHOULD BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE
ARCHITECT FOR CLARIFICATION.
2. THE ARCHITECT DISCLAIMS ANY RESPONSIBILITIES AND/OR
KNOWLEDGE OF ASBESTOS . THE OWNER ACCEPTS ALL
RESPONSIBILITY FOR REMOVAL AND DISPOSAL OF ASBESTOS
IF DISCOVERED. ANY IMPACT OF ASBESTOS CONTAINING
BUILDING MATERIALS MUST BE COORDINATED.
3. ALL WORK SHALL BE IN COMPLIANCE WITH LOCAL AUTHORITY
HAVING JURISDICTION AND INTERNATIONAL BUILDING CODE
2021.
4. ALL WORK SHALL BE IN COMPLIANCE WITH THE
CONSTRUCTION SPECIFICATION MANUAL WHICH IS PART OF
THE PROJECT DOCUMENTS.
5. ALL ABANDONED WIRING, CONDUITS OR MISC. MEP MUST BE
REMOVED.
6. ALL DEMOLITION AND DISPOSAL MUST BE DONE TO MEET ALL
CODES AND LAWS FOR PROPER DISPOSAL.
7. ALL RETURN AIR DUCTS MUST BE FILTERED DURING DEMO
AND CONSTRUCTION TO PREVENT DEBRIS FROM ENTERING
HVAC SYSTEM.
PROJECT NO.: INITIAL DATE:
DRAWN BY: CHECKED BY:
ARCHITECTURAL WORKSHOP . DENVER, COLORADO
A R
C H
IT
E
C T
U R
A L
W O
R K
S H
O P
, L
LC
. A
LL
R
IG
H T
S R
E S
E R
V E
D
2417mcc JUNE 2024
ZEAP JM
2024-107_MORGAN CC
WRAY CAMPUS T.I.
300 DEXTER ST
WRAY CO, 80758
AD-103
DEMO CEILING PLAN
1/4" = 1'-0"1 DEMO CEILING PLAN
DATE DESCRIPTION
UNISEX
RESTROOM
UNISEX
RESTROOM
UTILITY /
STORAGE
LAB /
CLASSROOM
LOBBY
COMPUTER
LAB
OPEN
OFFICE
OFFICE
OFFICE
EXIT
ACCESS
A-40110
10' - 6 7/8" 3' - 0" 13' - 5" 3' - 9" 15' - 6 7/8" 5' - 4 7/8" 4' - 10 1/2" 5' - 8 3/8" 5' - 6 7/8"
6' - 0 1/8" 10' - 7 5/8" 10' - 4 7/8" 2' - 8 1/4" 4' - 3 1/2" 7' - 3 3/8" 10' - 4 7/8" 16' - 1 3/4"
8'
/8
/8
7'
/8
8'
/8 "6'
/8
5'
/8
7'
7/ 8"
4'
/2
006B
A-401
A-401
4 4
5 5
8 9
8 9
A-501
A-501
15 15
1 4
1 4
A-401
4'
/4
7'
7/ 8"
5'
/8
2'
/8
8'
/4
5'
/2
6A
BREAKROOM
A A
A-501
A-501
A-501
A-501
A-201
A-201
A-201
5' - 8 5/8" 6' - 4 1/8"
/8
GENERAL NOTES:
1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. ANY
DISCREPANCIES IN DRAWINGS AND/OR EXISTING CONDITIONS
SHOULD BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE
ARCHITECT FOR CLARIFICATION.
2. THE ARCHITECT DISCLAIMS ANY RESPONSIBILITIES AND/OR
KNOWLEDGE OF ASBESTOS. THE OWNER ACCEPTS ALL
RESPONSIBILITY FOR REMOVAL AND DISPOSAL OF ASBESTOS
IF DISCOVERED.
3. NEW CONSTRUCTION MUST ALIGN WITH EXISTING STR.
GRID, WALLS, AND / OR OTHER ELEMENTS AS INDICATED.
4. SEE MEP FOR ALL ENGINEERING NOTES AND SCHEDULES.
5. DOORS IN STUD WALLS THAT ARE NOT SPECIFICALLY
LOCATED, PROVIDE A HINGE SIDE JAMB DIMENSION OF 6"
FROM DOOR OPENING TO ADJACENT WALL. ALL DOORS TO
HAVE KING STUDS (2X) BOTH SIDES.
6. PROVIDE BLOCKING IN THE WALL AS REQUIRED TO SECURE
COUNTERTOPS, CABINETRY AND SHELVING.
7. ALL DIMENSIONS ARE FROM FACE OF STUD, CABINETS,
ROUGH OPENINGS OR CENTERLINE OF GRID UNLESS NOTED
OTHERWISE.
8. ALL INTERIOR WALLS TO BE WALL TYPE 1 UNLESS OTHERWISE
NOTED.
9. SUBMIT MILLWORK SHOP DRAWINGS AND FINISH SUBMITTALS
TO ARCHITECT FOR APPROVAL BEFORE FABRICATION OR
INSTALLATION.
10. ALL ROUGH AND FINISH CONSTRUCTION SHALL BE IN
COMPLIANCE WITH GOVERNING CODES AND REGULATIONS AS
A MINIMUM STANDARD.
11. SEE SHEET G-002 FOR CONSTRUCTION TYPE AND CODE
INFORMATION.
12. SEE SHEET I-101 FOR ACCESSORY SCHEDULE AND G-003
FOR MOUNTING HEIGHTS.
13. ALL DRAWINGS, SCHEDULES, AND SPECIFICATIONS IN
CONSTRUCTION SET ARE TO BE CONSIDERED AS A WHOLE
AND ARE TO BE REFERENCED FOR ADDITIONAL INFORMATION.
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO
COORDINATE ALL PHASES OF DEMOLITION AND
CONSTRUCTION.
FLOOR PLAN KEYNOTES:
GENERAL CONTRACTOR TO LEVEL AND OR GRIND EXISTING
CONCRETE FLOORS AS REQUIRED FOR NEW FLOORING, INSTALL
PER MANUFACTURER'S REQUIREMENTS. CONTRACTOR TO
PROVIDE MOISTURE BARRIER AS RECOMMENDED BY FLOORIN
MNAUFACTURER.
INSTALL NEW WINDOW SHADES PER MANUFACTURER'S
INSTRUCTIONS, RE: FINISH SCHEDULE FOR ADDITIONAL
INFORMATION.
NEW CASEWORK AND SOLID SURFACE COUNTER RE:
INTERIOR ELEVATIONS, FINISH SCHEDULE, AND DETAILS FOR
ADDITIONAL INFORMATION.
NEW FLOOR FINISH AND BASE, RE: INTERIOR FINISH PLAN
AND FINISH SCHEDULE FOR ADDITIONAL INFORMATION.
EXISTING COLUMN TO REMAIN, PROTECT DURING
CONSTRUCTION, PATCH AND REPAIR DRYWALL AS REQUIRED
FOR NEW FINISHES.
OWNER PROVIDED TELEVISION, CONTRACTOR INSTALLED ON
LOW PROFILE ADA WALL BRACKET, RE: MEP DRAWINGS FOR
ADDITIONAL INFORMATION.
GENERAL CONTRACTOR TO LEVEL AND OR GRIND EXISTING
CONCRETE FLOORS AS REQUIRED THOUGHOUT.
REINSTALL EXISTING SALVAGED RESTROOM LAVATORY AND
MIRROR PER ADA STANDARDS RE: SHEET G-003 FOR MOUNTING
HEIGHTS AND MEP DRAWINGS FOR ADDITIONAL INFORMATION.
REINSTALL EXISTING SALVAGED GRAB BARS AND TOILET PAPER
DISPENSER PER ADA STANDARDS, RE: SHEET G-003 FOR
MOUNTING HEIGHTS.
EXISTING ALUMINUM STOREFRONT TO REMAIN, REPLACE
EXISTING FAILED IGU, METAL TRIM, AND SEALANT AS REQUIRED.
ALUMINUM STOREFRONT FRAME TO BE PAINTED EP-1 ON THE
INTERIOR AND EXTERIOR. RE: EXTERIOR FINISH SCHEDULE.
INSTALL NEW KWIK-WALL VL2-35 STC ACCORDION PARTITION,
COLOR: LINDEN, DOVER GRAY, KWC-5 PER MANUFACTURER'S
INSTRUCTIONS.
ADD METAL HAT CHANNELS AS NEEDED TO APPLY GYP. BD. TO
EXISTING WALL ASSEMBLY.
INSTALL NEW FRP UP TO 6'-0" A.F.F., RE: FINISH PLAN AND FINISH
SCHEDULE FOR ADDITIONAL INFORMATION.
FUR OUT EXISTING WALLS TO BRING EXISTING TOILETS INTO
COMPLIANCE WITH ADA STANDARDS, RE: WALL TYPES AND
SHEET G-003 FOR STANDARDS.
INSTALL NEW SIMLABSOLUTIONS 30" SIMULATED MIRAGE
SURFACE MOUNTED HEADWALL PER MANUFACTURER'S
SPECIFICATIONS. MOUNT O.C. 60" A.F.F.
INSTALL NEW 1 1/2 SQUARE SEMI-RECESSED FIRE
EXTINGUISHER CABINET PER MANUFACTURER SPECIFICATIONS.
VERIFY WITH LOCAL FIRE AUTHORITY ON THE FINAL LOCATION.
INSTALL OWNER COPY MACHINE. RE: MEP DRAWINGS FOR
ADDITIONAL INFORMATION.
INSTALL NEW 10" TALL METAL KICKPLATE AT EXISTING
STOREFRONT DOORS. CAVITIES CREATED BY THE KICKPLATE
SHALL BE CAPPED.
EXISTING DOOR TO REMAIN
FLOOR PLAN LEGEND
EXISTING WALL TO REMAIN
NEW DOOR
EX
NEW CONSTRUCTION
NEW CASEWORK
NEW CASEWORK OVERHEAD
PROJECT NO.: INITIAL DATE:
DRAWN BY: CHECKED BY:
ARCHITECTURAL WORKSHOP . DENVER, COLORADO
A R
C H
IT
E
C T
U R
A L
W O
R K
S H
O P
, L
LC
. A
LL
R
IG
H T
S R
E S
E R
V E
D
2417mcc JUNE 2024
ZEAP JM
2024-107_MORGAN CC
WRAY CAMPUS T.I.
300 DEXTER ST
WRAY CO, 80758
A-101
CONSTRUCTION PLAN
1/4" = 1'-0"1 CONSTRUCTION PLAN
DATE DESCRIPTION
07/19/2024 100% DESIGN DEVELOPMENT
02/24/2025 ADDENDUM #1 - CODE REVIEW
RESTROOM
UNISEX
RESTROOM
UTILITY /
STORAGE
LAB /
CLASSROOM
LOBBY
COMPUTER
LAB
OPEN
OFFICE
OFFICE
009OFFICE
EXIT
ACCESS
BREAKROOM
GENERAL NOTES:
1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. ANY
DISCREPANCIES IN DRAWINGS AND/OR EXISTING CONDITIONS
SHOULD BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE
ARCHITECT FOR CLARIFICATION.
2. THE ARCHITECT DISCLAIMS ANY RESPONSIBILITIES AND/OR
KNOWLEDGE OF ASBESTOS. THE OWNER ACCEPTS ALL
RESPONSIBILITY FOR REMOVAL AND DISPOSAL OF ASBESTOS
IF DISCOVERED.
3. NEW CONSTRUCTION MUST ALIGN WITH EXISTING STR.
GRID, WALLS, AND / OR OTHER ELEMENTS AS INDICATED.
4. SEE MEP FOR ALL ENGINEERING NOTES AND SCHEDULES.
5. DOORS IN STUD WALLS THAT ARE NOT SPECIFICALLY
LOCATED, PROVIDE A HINGE SIDE JAMB DIMENSION OF 6"
FROM DOOR OPENING TO ADJACENT WALL. ALL DOORS TO
HAVE KING STUDS (2X) BOTH SIDES.
6. PROVIDE BLOCKING IN THE WALL AS REQUIRED TO SECURE
COUNTERTOPS, CABINETRY AND SHELVING.
7. ALL DIMENSIONS ARE FROM FACE OF STUD, CABINETS,
ROUGH OPENINGS OR CENTERLINE OF GRID UNLESS NOTED
OTHERWISE.
8. ALL INTERIOR WALLS TO BE WALL TYPE 1 UNLESS OTHERWISE
NOTED.
9. SUBMIT MILLWORK SHOP DRAWINGS AND FINISH SUBMITTALS
TO ARCHITECT FOR APPROVAL BEFORE FABRICATION OR
INSTALLATION.
10. ALL ROUGH AND FINISH CONSTRUCTION SHALL BE IN
COMPLIANCE WITH GOVERNING CODES AND REGULATIONS AS
A MINIMUM STANDARD.
11. SEE SHEET G-002 FOR CONSTRUCTION TYPE AND CODE
INFORMATION.
12. SEE SHEET I-101 FOR ACCESSORY SCHEDULE AND G-003
FOR MOUNTING HEIGHTS.
13. ALL DRAWINGS, SCHEDULES, AND SPECIFICATIONS IN
CONSTRUCTION SET ARE TO BE CONSIDERED AS A WHOLE
AND ARE TO BE REFERENCED FOR ADDITIONAL INFORMATION.
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO
COORDINATE ALL PHASES OF DEMOLITION AND
CONSTRUCTION.
EXISTING DOOR TO REMAIN
FLOOR PLAN LEGEND
EXISTING WALL TO REMAIN
NEW DOOR
EX
NEW CONSTRUCTION
NEW CASEWORK
NEW CASEWORK OVERHEAD
PROJECT NO.: INITIAL DATE:
DRAWN BY: CHECKED BY:
ARCHITECTURAL WORKSHOP . DENVER, COLORADO
A R
C H
IT
E
C T
U R
A L
W O
R K
S H
O P
, L
LC
. A
LL
R
IG
H T
S R
E S
E R
V E
D
2417mcc JUNE 2024
ZEAP JM
2024-107_MORGAN CC
WRAY CAMPUS T.I.
300 DEXTER ST
WRAY CO, 80758
A-102
FURNITURE PLAN
1/4" = 1'-0"1 FURNITURE PLAN
FURNITURE FOR REFERENCE
ONLY - CONFIRM WITH
BUILDING TENANT ALL
FURNITURE LAYOUT AND CUT
SHEETS
FOR REFERENCE ONLY
DATE DESCRIPTION
EX GYP. BD.
8' - 0" A.F.F.
EX GYP. BD.
8' - 0" A.F.F.
UNISEX
RESTROOM
UNISEX
RESTROOM
OFFICE
UTILITY /
STORAGE
LAB /
CLASSROOM
OFFICE
009LOBBY
EXIT
ACCESS
COMPUTER
LAB
OPEN
OFFICE
ACT CEILING
9' - 7" A.F.F.
ACT CEILING
9' - 7" A.F.F.
ACT CEILING
9' - 7" A.F.F.
ACT CEILING
9' - 7" A.F.F.
9' - 7" A.F.F.
ACT CEILING
ACT CEILING
9' - 7" A.F.F.
ACT CEILING
9' - 7" A.F.F.
ACT CEILING
9' - 7" A.F.F.
3 3
TYP.
TYP.
BREAKROOM
ACT CEILING
9' - 7" A.F.F.
3 4
A-103
12' - 9 1/4" 21' - 0 7/8" 22' - 3 3/8" 12' - 7 1/4"
GENERAL NOTES:
1. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. ANY
DISCREPANCIES IN DRAWINGS AND/OR EXISTING CONDITIONS
SHOULD BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE
ARCHITECT FOR CLARIFICATION.
2. THE ARCHITECT DISCLAIMS ANY RESPONSIBILITIES AND/OR
KNOWLEDGE OF ASBESTOS. THE OWNER ACCEPTS ALL
RESPONSIBILITY FOR REMOVAL AND DISPOSAL OF ASBESTOS
IF DISCOVERED.
3. NEW CONSTRUCTION MUST ALIGN WITH EXISTING STR.
GRID, WALLS, AND / OR OTHER ELEMENTS AS INDICATED.
4. SEE MEP FOR ALL ENGINEERING NOTES AND SCHEDULES.
5. DOORS IN STUD WALLS THAT ARE NOT SPECIFICALLY
LOCATED, PROVIDE A HINGE SIDE JAMB DIMENSION OF 6"
FROM DOOR OPENING TO ADJACENT WALL. ALL DOORS TO
HAVE KING STUDS (2X) BOTH SIDES.
6. PROVIDE BLOCKING IN THE WALL AS REQUIRED TO SECURE
COUNTERTOPS, CABINETRY AND SHELVING.
7. ALL DIMENSIONS ARE FROM FACE OF STUD, CABINETS,
ROUGH OPENINGS OR CENTERLINE OF GRID UNLESS NOTED
OTHERWISE.
8. ALL INTERIOR WALLS TO BE WALL TYPE 1 UNLESS OTHERWISE
NOTED.
9. SUBMIT MILLWORK SHOP DRAWINGS AND FINISH SUBMITTALS
TO ARCHITECT FOR APPROVAL BEFORE FABRICATION OR
INSTALLATION.
10. ALL ROUGH AND FINISH CONSTRUCTION SHALL BE IN
COMPLIANCE WITH GOVERNING CODES AND REGULATIONS AS
A MINIMUM STANDARD.
11. SEE SHEET G-002 FOR CONSTRUCTION TYPE AND CODE
INFORMATION.
12. SEE SHEET I-101 FOR ACCESSORY SCHEDULE AND G-003
FOR MOUNTING HEIGHTS.
13. ALL DRAWINGS, SCHEDULES, AND SPECIFICATIONS IN
CONSTRUCTION SET ARE TO BE CONSIDERED AS A WHOLE
AND ARE TO BE REFERENCED FOR ADDITIONAL INFORMATION.
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO
COORDINATE ALL PHASES OF DEMOLITION AND
CONSTRUCTION.
CEILING PLAN KEYNOTES:
INSTALL NEW ACT CEILING GRID, AND LAY-IN CEILING TILES TO
MATCH AND ALIGN WITH EXISTING ACT CEILING.
INSTALL NEW / SALVAGED ACT CEILING TILES TO MATCH AND
ALIGN WITH EXISTING ACT CEILING WHERE EXISTING TROFFER
LIGHTS WERE DEMOED.
INSTALL NEW LED TROFFER LIGHTS IN ACT CEILING, RE: MEP
DRAWINGS FOR ADDITIONAL INFORMATION.
EXISTING ACT CEILING GRID AND CEILING TILES TO REMAIN,
PROTECT DURING CONSTRUCTION. PATCH AND REPAIR AS
REQUIRED WITH NEW / SALVAGED TILES / GRID FROM DEMOED
AREA TO MATCH EXISTING.
NEW LED STRIP LIGHTING FIXTURE, RE: MEP DRAWINGS FOR
ADDITIONAL INFORMATION.
INSTALL NEW LAMPING IN EXISTING SOFFIT CAN LIGHTS, RE:
MEP DRAWINGS FOR ADDITIONAL INFORMATION.
EXISTING GYP. BD. CEILING TO REMAIN, PROTECT DURING
CONSTRUCTION, PATCH AND REPAIR AS REQUIRED FOR NEW
PAINT.
INSTALL NEW LINO CHANNEL MOUNTED LINEAR LIGHTING
FIXTURES PER MANUFACTURER'S INSTRUCTIONS, RE: MEP
DRAWINGS FOR ADDITIONAL INFORMATION.
DEMO CEILING PLAN LEGEND
EXISTING WALL
NEW ACT CEILING
NEW TROFFER LIGHT
EXISTING ACT CEILING TO REMAIN
NEW CONSTRUCTION
NEW LED LINEAR FIXTURE
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
PROJECT NO.: INITIAL DATE:
DRAWN BY: CHECKED BY:
ARCHITECTURAL WORKSHOP . DENVER, COLORADO
A R
C H
IT
E
C T
U R
A L
W O
R K
S H
O P
, L
LC
. A
LL
R
IG
H T
S R
E S
E R
V E
D
2417mcc JUNE 2024
ZEAP JM
2024-107_MORGAN CC
WRAY CAMPUS T.I.
300 DEXTER ST
WRAY CO, 80758
A-103
CEILING PLAN
1/4" = 1'-0"1 CEILING PLAN
1/4" = 1'-0"2 EXTERIOR SOFFIT CEILING PLAN
ALT #1
ALT #1
DATE DESCRIPTION
FIRST FLOOR PLAN
100' - 0"
SOFFIT HEIGHT
111' - 2"
PARAPET HEIGHT
114' - 10"
EP-2
EP-2
EP-1
EP-4
EP-4 EP-2
EP-1
NEW WALL MOUNTED
EXTERIOR LIGHT FIXTURE,
RE: MEP DRAWINGS
FIRST FLOOR PLAN
100' - 0"
SOFFIT HEIGHT
111' - 2"
PARAPET HEIGHT
114' - 10"
EP-4
EP-4EP-4
EP-2
PARAPET SIDE
EP-2
EP-2
EP-2
PARAPET SIDE
EP-2
GUTTER / DOWNSPOUT GUTTER / DOWNSPOUT
FIRST FLOOR PLAN
100' - 0"
SOFFIT HEIGHT
111' - 2"
PARAPET HEIGHT
114' - 10"
EP-2
EP-4
EP-1
EP-2EP-2
NEW WALL MOUNTED
EXTERIOR LIGHT FIXTURE,
RE: MEP DRAWINGS
EP-4
EXTERIOR FINISH SCHEDULE:
MATERIAL: PAINT
PRODUCT: SHERWIN WILLIAMS
COLOR: SW 6510 LOYAL BLUE
EP-1
MATERIAL: PAINT
PRODUCT: SHERWIN WILLIAMS
COLOR: SW 6502 LOCH BLUE
EP-2
MATERIAL: PAINT
PRODUCT: SHERWIN WILLIAMS
COLOR: SW 6677 GOLDENROD
EP-3
MATERIAL: PAINT
PRODUCT: SHERWIN WILLIAMS
COLOR: SW 7662 EVENING SHADOW
EP-4
FIRST FLOOR PLAN
100' - 0"
SOFFIT HEIGHT
111' - 2"
PARAPET HEIGHT
114' - 10"
MORGAN COMMUNITY COLLEGE
EP-2
EP-2
EP-1EP-1
EP-4
EP-4
EP-1
EP-4EP-2
EP-1
EP-1
ALUM. STOREFRONT
EP-1
ALUM. STOREFRONT
EP-1
ALUM. STOREFRONT
EP-3 EP-3
NEW WALL MOUNTED
EXTERIOR LIGHT FIXTURE,
RE: MEP DRAWINGS
PROJECT NO.: INITIAL DATE:
DRAWN BY: CHECKED BY:
ARCHITECTURAL WORKSHOP . DENVER, COLORADO
A R
C H
IT
E
C T
U R
A L
W O
R K
S H
O P
, L
LC
. A
LL
R
IG
H T
S R
E S
E R
V E
D
2417mcc JUNE 2024
ZEAP JM
2024-107_MORGAN CC
WRAY CAMPUS T.I.
300 DEXTER ST
WRAY CO, 80758
A-201
EXTERIOR ELEVATIONS
3/16" = 1'-0"2 NORTH ELEVATION
3/16" = 1'-0"3 EAST ELEVATION
3/16" = 1'-0"4 SOUTH ELEVATION
3/16" = 1'-0"1 WEST ELEVATION
DATE DESCRIPTION
07/19/2024 100% DESIGN DEVELOPMENT
FIRST FLOOR PLAN
100' - 0"
SOFFIT HEIGHT
111' - 2"
PARAPET HEIGHT
114' - 10"
MP-1
MP-1
MP-1 B-1 B-1
EP-3
EP-3 D1
D2
D1
D2
D1
D2
2D2
D3
D1
D2
D1D1
D3D3
1' - 8 1/2"1' - 8 1/2"
D2 D2
3 33
EP-3
ALUM.
STOREFRONT
EP-3
ALUM.
STOREFRONT
EP-3
ALUM.
STOREFRONT
D1
D1
MP-2MP-2
MP-2MP-2
FIRST FLOOR PLAN
100' - 0"
PARAPET HEIGHT
114' - 10"
MP-1
MP-1MP-1 B-1 B-1
MP-2
EP-3
B
D1
D2
D1
D2
D1
D2
2 2
D2
D2
D1
D2
FIRST FLOOR PLAN
100' - 0"
PARAPET HEIGHT
114' - 10"
EP-1
EP-2
MP-1MP-1
EP-1
PARAPET SIDE
EP-1
GUTTER / DOWNSPOUT
EP-1
PARAPET SIDE
EP-1
GUTTER / DOWNSPOUT
D2
D3
D3D3
D2
D1
FIRST FLOOR PLAN
100' - 0"
PARAPET HEIGHT
114' - 10"
B-1
MP-1
D1
D2
D2
D1
D2
D1
D2
MP-1MP-1
EXTERIOR FINISH SCHEDULE:
MATERIAL: THIN BRICK
MANUFACTURER: ENDICOTT
PRODUCT: THIN BRICK
COLOR: GRAPHITE
TEXTURE: SMOOTH
BOND PATTERN: VERTICAL STACKED BOND
SIZE: MODULAR
MORTAR: SPEC MIX, COLORED MORTAR / SM770 SABLE
B-1
MATERIAL: PAINT
PRODUCT: SHERWIN WILLIAMS
COLOR: MATCH METAL PANEL MILITARY BLUE
EP-1
MATERIAL: PAINT
PRODUCT: SHERWIN WILLIAMS
COLOR: SW 7662 EVENING SHADOW
EP-2
MATERIAL: METAL PANEL
MANUFACTURER: PAC-CLAD
PRODUCT: BOX RIB WALL PANEL SYSTEMS
COLOR: MILITARY BLUE
PROFILES: PANEL A: BOX RIB 1
PANEL B: BOX RIB 2
PANEL C: BOX RIB 3
PANEL PATTERN: A,B,C,A,B
MP-1
MATERIAL: PAINT
PRODUCT: SHERWIN WILLIAMS
COLOR: SW 6510 LOYAL BLUE
EP-3
MATERIAL: METAL PANEL
MANUFACTURER: TBD
PRODUCT: SHEET METAL PANEL
COLOR: SW 6510 LOYAL BLUE
MP-2
FIRST FLOOR PLAN
100' - 0"
PARAPET HEIGHT
114' - 10"
MP-1
EP-2
MP-1MP-1
EP-1
PARAPET SIDE
EP-1
GUTTER / DOWNSPOUT
EP-1
PARAPET SIDE
EP-1
GUTTER / DOWNSPOUT
D2
D2
D2
D1
D3D3
DEMO ELEVATION KEYNOTES:
DEMO AND DISPOSE OF EXISTING EXTERIOR CMU FAUX
PANELING AND SHEATHING BACK TO EXISTING METAL WALL
STUDS.
DEMO AND DISPOSE OF EXISTING METAL PANELING AND
SHEATHING BACK TO EXISTING METAL STUDS.
EXISTING METAL PANELING TO REMAIN PROTECT DURING
CONSTRUCTION AND PAINT AS NOTED.
D1
D2
D3
ELEVATION KEYNOTES:
INSTALL NEW THIN BRICK PER DETAILS ON SHEET A-502.
INSTALL NEW METAL PANELING SYSTEM AND REQUIRED
BACKING PER DETAILS ON SHEET A-502.
FRAME OUT EXISTING WALL AND PROVIDE EXTERIOR GYP. BD.
SHEATHING / OR PLYWOOD. THEN INSTALL BRAKE METAL AND
PAINT AS NOTED.
PROJECT NO.: INITIAL DATE:
DRAWN BY: CHECKED BY:
ARCHITECTURAL WORKSHOP . DENVER, COLORADO
A R
C H
IT
E
C T
U R
A L
W O
R K
S H
O P
, L
LC
. A
LL
R
IG
H T
S R
E S
E R
V E
D
2417mcc JUNE 2024
ZEAP JM
2024-107_MORGAN CC
WRAY CAMPUS T.I.
300 DEXTER ST
WRAY CO, 80758
A-202
EXTERIOR ELEVATIONS
3/16" = 1'-0"1 WEST ELEVATION
3/16" = 1'-0"2 NORTH ELEVATION
3/16" = 1'-0"4
EAST ELEVATION
3/16" = 1'-0"3 SOUTH ELEVATION
3/16" = 1'-0"5
EAST ELEVATION
ALT #1
ALT #1
ALT #1
ALT #1
ALT #2
DATE DESCRIPTION
07/19/2024 100% DESIGN DEVELOPMENT
AC
01FRP-1
P-1
6'
RB-1
2' - 10"
AC
FRP-1
P-1
6'
RB-1
AC
FRP-1
P-1
RB-1
6'
1' - 4"
3' - 0 5/8"
AC
6'
FRP-1
P-1
P-2
RB-1
AC
FRP-1
P-1
6'
RB-1
FRP-1
P-1
6'
P-2
RB-1
AC
FRP-1
P-1
AC
6'
RB-1
1' - 4"
3' - 0 5/8"
AC
FRP-1
P-1
AC
6'
RB-1
0' - 1 1/2" 2' - 6" 3' - 0" 2' - 6" 2' - 6" 0' - 1 1/2"
10' - 9"
1'
3'
4'
9'
P-1
P-1 SS-1
PLAM-1
PLAM-1
A-501
A-501
RB-1
P-1
SS-1
PLAM-1
P-1PLAM-1
1'
3'
1'
2'
0"
9'
1 3/8" 1' - 9" 3' - 0" 2' - 9" 2' - 6" 1 3/8"
10' - 2 3/4"
A-501
A-501
A-501
A-501
RB-1
PROJECT NO.: INITIAL DATE:
DRAWN BY: CHECKED BY:
ARCHITECTURAL WORKSHOP . DENVER, COLORADO
A R
C H
IT
E
C T
U R
A L
W O
R K
S H
O P
, L
LC
. A
LL
R
IG
H T
S R
E S
E R
V E
D
2417mcc JUNE 2024
ZEAP JM
2024-107_MORGAN CC
WRAY CAMPUS T.I.
300 DEXTER ST
WRAY CO, 80758
A-401
INTERIOR ELEVATIONS
3/8" = 1'-0"1 RR 003 - WEST ELEVATION
3/8" = 1'-0"2 RR 003 - NORTH ELEVATION
3/8" = 1'-0"3 RR 003 - EAST ELEVATION
3/8" = 1'-0"4 RR 003 - SOUTH ELEVATION
3/8" = 1'-0"7 RR 004 - EAST ELEVATION
3/8" = 1'-0"8 RR 004 - SOUTH ELEVATION
3/8" = 1'-0"5 RR 004 - WEST ELEVATION
3/8" = 1'-0"6 RR 004 - NORTH ELEVATION
3/8" = 1'-0"10 LAB / CLASSROOM 006 - NORTH ELEVATION
3/8" = 1'-0"9 BREAKROOM 011 - EAST ELEVATION
DATE DESCRIPTION
EXISTING ACT CEILING
3 5/8" METAL STUDS, 16"
O.C. U.N.O.
PROVIDE UNFACED
SOUND BATT INSULATION
FULL HEIGHT
SEALANT, CONT. AT BASE
RATING: NON-RATED
5/8" GYP. BD. BOTH SIDES
FASTEN PER MFR.
RECOMMENDATION
RUBBER WALL BASE,
RE: FINISH SCHEDULE
PROVIDE ANGLE BRACE
AT 8'-0" O.C. FROM T.O.
WALL TO B.O. STR.
PROVIDE SOUND BATT
INSULATION 4'-0" EACH SIDE
AT ALL NEW WALL
LOCATIONS.
PER SCH.
2" 5/
8"
FRAMING PER WALL TYPE.
DOUBLE STUD JAMB POST
H.M. FRAME & SOLID
WOOD DOOR
RE: DOOR SCHEDULEHEAD
P E
R S
C H
2" 5/8"
FRAMING PER WALL TYPE.
DOUBLE STUD JAMB POST
H.M. FRAME AND SOLID
WOOD DOOR
RE: DOOR SCHEDULE
JAMB
PLAM FULL HEIGHT
DOOR TO PROVIDE ADA
ACCESS W/ INTEGRAL
TOE KICK
RB-1.
SOLID SURFACE
COUNTER TOP, RE:
FINISH SCH. AND
INTERIOR ELEVS.
CABINET BACK PER AWI
STANDARDS
FAUCET, RE: PLUMB.
DWGS…