2024-05-23_Port Huron Bidding _ Construction (Dwgs).pdf

PDF 11 MB Posted

Attached to
MOC Parking Structure Rehabilitation Project
Solicitation number
G23-0010
Issued by
Monroe County, Michigan

About this file

This document is a set of construction drawings for the City of Port Huron Parking Structure Repairs 2024 project, prepared by Walker Consultants. The project involves comprehensive rehabilitation of a multi-level parking structure, with detailed repair plans spanning both lower and upper levels. The drawings, dated May 23, 2024, outline extensive repair work including post-tensioned tendon repairs, concrete slab and edge repairs, traffic coating applications, masonry restoration, joint sealing, and infrastructure improvements such as removing and reinstalling parking meter posts and ADA signage.

The project scope includes specific repair techniques for concrete structural elements, including partial and full-depth concrete repairs, tendon inspection and replacement, traffic coating reapplication, tuckpointing of masonry facades, and replacement of structural components like shelf angles and lintels. The detailed drawings provide technical specifications for each repair type, indicating a comprehensive approach to restoring the parking structure's structural integrity and surface conditions. While no specific budget is mentioned in the drawings, the extensive and detailed repair plans suggest a significant investment in maintaining and upgrading the City of Port Huron's parking infrastructure.

View the file

Other files

File Type Posted
Addendum No. 2_City of Port Huron PS Repairs 2024.pdf PDF
00100Advertisement Bids.doc DOC document
Addendum No.1_City of Port Huron PS Repairs 2024.pdf PDF
Spec Book.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PARKING STRUCTURE REPAIRS 2024

LOCATION MAP

PORT HURON, MICHIGAN

CITY OF PORT HURON

Copyright 2023. All rights reserved. No part of this document may be reproduced in any form or by any means without permission from Walker Consultants

BIDDING AND CONSTRUCTION

MAY 23, 2024

R-001 GENERAL NOTES, WORK ITEM LIST

R-101 LOWER LEVEL PLAN

R-102 UPPER LEVEL PLAN

R-501 REPAIR DETAILS

R-502 REPAIR DETAILS

R-503 REPAIR DETAILS

R-504 REPAIR DETAILS

R-505 REPAIR DETAILS

NORTH

C O N S U L T A N T S

WALKER

525 Avis Drive Suite 1 Ann Arbor, MI 48108

734.663.1070 Ph

www.walkerconsultants.com

PROJECT SITE

R-001

GENERAL NOTES,

WORK ITEM LIST

SHEET TITLE:

D

ES

C R

IP

TI

O N

IS

SU

E:

M

AR

K D

AT

E

PROJECT NO:

DRAWN BY:

CHECKED BY:

20-002368.00

Copyright 2023. All rights reserved. No part of this document may be reproduced in any form or by any means without permission from Walker Consultants

J:

\M

IC

H

IG

AN

\2 0-

-0

0-

PO

R T_

H U

R O

N _M

O C

_P S_

_R

PR

S\ D

R

AW

IN

G

S\

R

-0

.D W

G

/1 4/

1:

:3

AM

W

YL

IE

, K

EV

IN

C O

N S

U L

T A

N T

S W A L K E R

Av is

D riv e Su ite

An n

Ar bo r, M

I 4

4.

3.

P h w w w

.w al ke rc on su lta nt s.

co m

M

IC

H

IG

AN

PA

R

KI

N

G S

TR

U

C

TU

R E

R

EP

AI

R

S

C

IT

Y O

F

PO

R T

H U

R O

N

PO

RT

H

UR

ON

ECC

EK

BI

D

D

IN

G A

N D

C O

N

ST

R U

C

TI

O N

/2

3/

MECHANICAL

EQUIPMENT

STORAGE

STORAGE

OPEN TO

ABOVE

RAMP DOWN

EVIDENCE

ROOM

CLOSETS

EVIDENCE

ROOM

NORTH

LOWER LEVEL PLAN1

1. CONTRACTOR TO DEVELOP PHASING PLAN / SCHEDULE /

WORK SEQUENCE FOR OWNER APPROVAL PRIOR TO START

OF WORK.

2. INSTALL OVERHEAD PROTECTION, BARRICADES, TEMPORARY

SIGNAGE/TRAFFIC CONTROLS PER GENERAL REQUIREMENTS

OF W.I. 1.5 AND AS REQUIRED BY OWNER.

3. GENERAL WORK LOCATIONS SHOWN ARE REPRESENTATIVE

OF THE TYPES OF REPAIR WORK REQUIRED. SPECIFIC

REPAIR WORK LOCATIONS ARE TO BE DETERMINED IN THE

FIELD WITH ENGINEER AND CONFIRMED WITH OWNER.

CONTRACTOR SHALL NOT EXCEED BID QUANTITIES WITHOUT

WRITTEN AUTHORIZATION FROM OWNER. PROVIDE OWNER

WITH REGULAR UPDATES ON WORK ITEM QUANTITY

PROGRESS AND PROJECTIONS.

UNLESS NOTED OTHERWISE, THE FOLLOWING WORK IS

GENERALLY LISTED IN ORDER OF W.I. NUMBER AND IS NOT

INDICATIVE OF THE ORDER THAT THE WORK SHOULD BE

PERFORMED. CONTRACTOR REQUIRED TO COORDINATE AND

SEQUENCE WORK IN A LOGICAL AND EFFICIENT MANNER AS

APPROVED BY OWNER/ENGINEER:

4. POST TENSION TENDON REPAIRS (W.I. SERIES 21.0) AND

ASSOCIATED FULL DEPTH FLOOR REPAIRS (W.I.'S 3.3A & 3.3B)

SHALL BE DETERMINED IN FIELD WITH ENGINEER AFTER

CONCRETE REMOVALS PER W.I.'S 3.1A, 3.1B, 3.4, AND 4.1 HAVE

BEEN COMPLETED AND THE P/T TENDONS WITHIN THE FLOOR

CAVITIES ARE READY FOR REVIEW. COORDINATE WITH

ENGINEER. NOTIFY ENGINEER OF ALL BROKEN TENDONS AS

THEY ARE DISCOVERED, AND PROVIDE SHORING AS NEEDED

TO SUPPORT SLAB, BEAMS, AND APPLIED LOADS. ADDITIONAL

REMOVAL OF SOUND CONCRETE TO INSPECT TENDONS, AS

DIRECTED BY ENGINEER, SHALL BE PAID FOR BY ANY

COMBINATION OF W.I.'S 3.1A, 3.1B, OR 3.4 AS APPLICABLE.

5. W.I. 3.10: NOT SHOWN ON PLANS. OCCURS AS NEEDED AS

DIRECTED BY THE ENGINEER WHEN ADDITIONAL STEEL

REINFORCEMENT (BEYOND WHAT IS IDENTIFIED IN THE

CONSTRUCTION DOCUMENTS) IS REQUIRED TO COMPLETE

CONCRETE REPAIRS PER W.I. SERIES' 3.0, 4.0, AND 5.0.

6. W.I.3.14: FILL VOIDS AS NEEDED BENEATH LOWER-LEVEL FULL

DEPTH CONCRETE REPAIR AREAS TO PROVIDE A UNIFORM

AND STABLE BACKING SURFACE LEVEL WITH THE BOTTOM OF

THE ADJACENT FLOOR SLAB SURFACES FOR FULL-DEPTH

CONCRETE REPAIRS.

7. W.I. 4.9: THIS WORK OCCURS WHERE ALL LOOSE OVERHEAD

CONCRETE IS IDENTIFIED OUTSIDE AREAS WHERE WORK IS

COMPLETED. THIS WORK ALSO INCLUDES REMOVING ALL

OVERHEAD FORMWORK (OR SIMILAR TEMPORARY FEATURES)

LEFT IN PLACE DURING PAST CONSTRUCTION PROJECTS

OUTSIDE AREAS WHERE WORK IS COMPLETED.

8. W.I. 5.1/6.1: BEAM AND COLUMN REPAIRS OCCUR ON

UNDERSIDE OF UPPER LEVEL. LOCATE IN FIELD WITH

ENGINEER.

9. W.I. 11.1: OCCURS AT UPPER- AND LOWER-LEVEL FLOOR

SLABS. NOT SHOWN ON LOWER-LEVEL PLAN. ROUT AND SEAL

PREVIOUSLY UNSEALED, RANDOM CRACKING IN THE FLOOR

SLAB SURFACE.

10. W.I. 11.2: OCCURS AT LOWER- AND UPPER-LEVEL FLOOR

SLABS. NOT SHOWN ON LOWER-LEVEL PLAN. REPAIR

SEALANT IN ALL PREVIOUSLY SEALED CONSTRUCTION JOINTS,

CONTROL JOINTS, AND RANDOM CRACKING IN THE FLOOR

SLAB SURFACE.

11. W.I. 11.7: RESEAL ALL JOINTS WHERE HORIZONTAL FLOOR

SURFACES MEET A VERTICAL SURFACE. THIS WORK

GENERALLY OCCURS AT THE BASE OF COLUMNS, CURBS,

RAILING POSTS, AND WALLS.

12. W.I. 16.1: INSTALL NEW, STANDARD TRAFFIC COATING

SYSTEM ON FLOOR SURFACES WHERE A TRAFFIC COATING

MEMBRANE WAS NOT PREVIOUSLY INSTALLED. THIS WORK

GENERALLY OCCURS IN THE LOWER-LEVEL MECHANICAL

ROOM. THIS WORK EXCLUDES NON-PREVIOUSLY COATED

CURB SURFACES ON THE LOWER LEVEL.

13. W.I. 16.3: NOT SHOWN ON PLAN. REPAIR TRAFFIC COATINGS

AS NEEDED WHERE EXISTING TRAFFIC COATING SYSTEMS

HAVE DEBONDED FROM THE FLOOR SLAB IN AREAS

RECEIVING TRAFFIC COATING PER W.I.'S 16.4A AND 16.4B.

THIS WORK ALSO APPLIES TO REPAIRED CONCRETE

SURFACES CONTAINED WITHIN A PREVIOUSLY COATED AREA.

14. W.I. 16.4A: RECOAT FLOOR SURFACES WHERE A STANDARD

TRAFFIC COATING SYSTEM WAS PREVIOUSLY APPLIED.

SURFACES GENERALLY INCLUDE, BUT ARE NOT LIMITED TO,

THE PORTIONS OF THE LOWER-LEVEL STRUCTURAL SLAB

WITHOUT A CURB AND THE PORTIONS OF THE UPPER-LEVEL

STRUCTURAL SLAB WHICH HAVE BEEN OVERLAID. BASE BID

WORK SCOPE GENERALLY INCLUDES THESE SURFACES

NORTH OF GRID LINE 8.

15. W.I. 16.4B: RECOAT FLOOR SURFACES WHERE KELMAR

TRAFFIC COATING WAS PREVIOUSLY APPLIED. SURFACES

INCLUDE PORTIONS OF THE UPPER-LEVEL STRUCTURAL SLAB

WHICH HAVE NOT BEEN OVERLAID.

16. W.I. 25.1: APPLIES AS NEEDED WHERE REMOVAL AND

REINSTALLATION OF EXISTING OBSTACLES INCLUDING, BUT

NOT LIMITED TO, DRAINPIPE, STANDPIPE, SPRINKLERS,

CONDUIT, LIGHT FIXTURES, OR SIMILAR FEATURES IS

REQUIRED TO PERFORM OTHER WORK.

17. W.I. 45.1: INSTALL NEW PAVEMENT MARKINGS WHERE

EXISTING. EXISTING PAVEMENT MARKINGS ARE GENERALLY

LOCATED IN THE NORTH, UPPER-LEVEL PARKING AREA.

WORK ALSO INCLUDES PAINTING ALL CURB VERTICAL

SURFACES AND FIRST 6” OF THE ABUTTING HORIZONTAL

SURFACE AT BOTH LOWER- AND UPPER-LEVELS.

18. W.I. 50.2: REMOVE ALL PARKING METER POSTS AND REPAIR

EXISTING ANCHOR HOLES. ONLY OCCURS AT THE UPPER

LEVEL. DO NOT REMOVE BOLLARDS, PARCS EQUIPMENT,

SIGNPOSTS, LIGHT POSTS, ETC. CONTRACTOR TO CONFIRM

POSTS BEING REMOVED WITH ENGINEER PRIOR TO

PERFORMING WORK. PERFORM THIS WORK PRIOR TO

INSTALLING TRAFFIC COATING PER WORK ITEM SERIES 16.0.

19. W.I. 76.1A: OCCURS AT FAÇADE MASONRY ALONG THE

PERIMETER OF PARKING STRUCTURE WALLS. CONTRACTOR

SHALL PRIORITIZE AREAS WHERE FAÇADE MASONRY IS

LOOSE.

20. W.I. 76.2: REMOVE AND RESET FLUTED CMU TO REPLACE

SHELF ANGLE AND LINTEL PER W.I.'S 76.4A AND 76.4B. WORK

OCCURS ABOVE THE PEDESTRIAN DOORWAY AND GARAGE

DOOR WHICH PROVIDE ACCESS TO THE LOWER LEVEL AT THE

NORTH ELEVATION.

21. W.I. 76.5: OCCURS AT ALL JOINTS BETWEEN CAPSTONES

ALONG THE UPPER-LEVEL PARKING STRUCTURE PERIMETER.

WORK ALSO OCCURS AT THE TOP OF THE RETAINING WALLS

TO THE SOUTH OF THE STRUCTURE.

22. SEE SECTION 020010 FOR FURTHER INFORMATION AND

REQUIREMENTS REGARDING INDIVIDUAL WORK ITEMS.

SHEET NOTES:

X.X.X

WORK ITEM NUMBER

WORK ITEM IDENTIFICATION LEGEND

NOTES:

1. NOT ALL WORK ITEMS HAVE DETAILS.

2. SEE SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

XXX

WORK ITEM

NOTE (SEE

ABBREVIATIONS)

X

DETAIL NUMBER

SHEET NUMBER

DETAIL IDENTIFICATION LEGEND

R-XXX

CLARIFICATION

DETAIL NUMBER

EXPANSION JOINT (EJ)

PARTIAL DEPTH CONCRETE STRUCTURAL SLAB REPAIRS - W.I. 3.1A

GENERAL LEGEND

PARTIAL DEPTH CONCRETE OVERLAY REPAIR - W.I. 3.1B

CONCRETE CURB REPAIR - W.I. 3.4

16.1 TRAFFIC COATING - NEW SYSTEM (STANDARD)

16.4A TRAFFIC COATING - RECOAT (STANDARD)

16.4B TRAFFIC COATING - RECOAT (KELMAR)

CONCRETE STRUCTURAL SLAB/CEILING REPAIRS - W.I'S 3.3A, 3.3B, 4.1

3.1A 3.3B 21.0

SERIES

TAR TAR TAR

TAR

3.1A

TAR

TYP, ALONG

CURB EDGE

11.7

TYP

3.14

45.1 TYP, ALONG

CURB EDGE

45.1

11.7

TYP

11.7

TYP

TYP, ALONG

CURB EDGE

45.1

3.1A 3.3B 21.0

SERIES

TAR TAR TAR

TAR

3.14

3.1B

TAR

11.7

TYP

VEHICLE

REPAIR WELL

45.1 TYP, ALONG

CURB EDGE

76.4A

ABOVE GARAGE

DOOR

76.2

76.4B

ABOVE DOOR

76.2

UPPER LEVEL

SLAB EDGE

SOUTH

BUILDING

ENTRANCE

NORTH

BUILDING

ENTRANCE

IN

MECHANICAL

ROOM

16.1

TYP

ENTIRE

LOWER

LEVEL

16.4A

ALT

SHEET TITLE:

D

ES

C R

IP

TI

O N

IS

SU

E:

M

AR

K D

AT

E

PROJECT NO:

DRAWN BY:

CHECKED BY:

20-002368.00

Copyright 2023. All rights reserved. No part of this document may be reproduced in any form or by any means without permission from Walker Consultants

J:

\M

IC

H

IG

AN

\2 0-

-0

0-

PO

R T_

H U

R O

N _M

O C

_P S_

_R

PR

S\ D

R

AW

IN

G

S\

R

-1

.D W

G

/1 4/

1:

:5

AM

W

YL

IE

, K

EV

IN

C O

N S

U L

T A

N T

S W A L K E R

Av is

D riv e Su ite

An n

Ar bo r, M

I 4

4.

3.

P h w w w

.w al ke rc on su lta nt s.

co m

M

IC

H

IG

AN

PA

R

KI

N

G S

TR

U

C

TU

R E

R

EP

AI

R

S

C

IT

Y O

F

PO

R T

H U

R O

N

PO

RT

H

UR

ON

ECC

EK

BI

D

D

IN

G A

N D

C O

N

ST

R U

C

TI

O N

/2

3/

R-101

LOWER LEVEL

PLAN VIEW

5"

7" N

O M

IN

AL

3"

VARIES

SAW CUT PATCH

PERIMETER 3/4"

(TYP.) SEE NOTE 1

ORIGINAL SURFACE

REFER TO NOTE 2

SPALL OR

DELAMINATION

REMOVAL LIMITS

REMOVE AND REPLACE

CONCRETE WITHIN

SECTION SHOWN SHADED

REINFORCEMENT (TYP.), LOCATIONS APPROXIMATE.

CLEAN AND EPOXY COAT ALL EXPOSED REINF.

PROVIDE 3/4" CLEARANCE AROUND ALL EXPOSED

REINF. WHERE REQ'D AS SPECIFIED IN SECTION

"SURFACE PREPARATION FOR PATCHING"

EXISTING PT

STRUCTURAL SLAB

NOTES:

1. CAUTION, SLAB CONTAINS P/T TENDONS AND ANCHORING HARDWARE, DO NOT CUT OR DAMAGE.

IDENTIFY TENDON LOCATIONS PRIOR TO SAW CUTTING REPAIR PERIMETER.

2. REFER TO WORK ITEMS 3.1B OR 3.4 FOR EXISTING CONCRETE OVERLAY OR CURB REMOVAL.

(EXISTING OVERLAY OR CURB NOT SHOWN).

P/T TENDON,

LOCATION VARIES.

REPAIR DAMAGE

SHEATHING,

INCIDENTAL.

FLOOR REPAIR - PARTIAL DEPTH (P/T)

3.1A

6"

(V

IF

EX

IS

TI

N G

O

VE

R

LA

Y 5"

-7

EXISTING TRAFFIC

TOPPING. REPLACE WITH

NEW SYSTEM PER WI 16.1

NEW CONCRETE SHALL BE BONDED

TO STRUCTURAL SLAB. SURFACE

PREPARATION SHALL BE PER

SPECIFICATIONS. (INCIDENTAL)

P/T STRUCTURAL SLAB

(REINFORCEMENT NOT SHOWN).

W I 3

.1 A, .3

A, 3.

3B , 4

.0 S

ER

IE

S, AN

D

O R

1.

SE

R

IE

S

AS

N

EE

D

ED

W I 3

.1 B

NOTES:

1. PERFORM REMOVALS IN A MANNER THAT WILL NOT CAUSE DAMAGE TO STRUCTURAL SLAB.

2. PERFORM CONCRETE AND P/T REPAIRS TO THE STRUCTURAL SLAB PER OTHER WORK ITEMS.

3. PREPARE SURFACE PER REQUIREMENTS OF SECTION "SURFACE PREPARATION FOR PATCHING".

4. THICKNESS OF EXISTING OVERLAY VARIES. CONTRACTOR IS RESPONSIBLE TO MATCH EXISTING

ELEVATIONS AT PERIMETER BOUNDARY CONDITIONS, AND PROVIDE MINIMUM REQUIRED SLOPE TO

PREVENT PONDING.

5. TOOL AND SEAL CONTROL JOINTS THROUGH REPAIR TO MATCH EXISTING PER WORK ITEM 11.4.

REINFORCEMENT (TYP). LOCATIONS APPROXIMATE. CLEAN

AND APPLY CORROSION INHIBITOR TO ALL EXPOSED REINF.

PROVIDE 3/4" CLEARANCE AROUND ALL EXPOSED REINF.

WHERE REQ'D AS SPECIFIED IN SECTION "SURFACE

PREPARATION FOR PATCHING AND OVERLAY".

FLOOR REPAIR -

PARTIAL DEPTH (OVERLAY)

3.1B

REMOVE AND REPLACE

CONCRETE WITHIN

SECTION SHOWN SHADED.

SAWCUT PATCH

PERIMETER 3/4"

(TYP)

VARIES

3"

VARIES

PT STRUCTURAL SLAB

REMOVAL LIMITS

ORIGINAL SURFACE

GRIND OR SAWCUT

PATCH PERIMETER

1/2" (TYP.)

REMOVE AND REPLACE CONCRETE

WITHIN SECTION SHOWN SHADED REINFORCEMENT (TYP.),

LOCATIONS

APPROXIMATE. CLEAN

AND EPOXY COAT ALL

EXPOSED REINF.

PROVIDE 3/4" CLEARANCE

AROUND ALL EXPOSED

REINF. WHERE REQ'D AS

SPECIFIED IN SECTION

"SURFACE PREPARATION

FOR PATCHING".

SPALL OR

DELAMINATION

CAUTION, SLAB CONTAINS P/T TENDONS (NOT SHOWN), DO NOT CUT OR DAMAGE.

NOTES:

1.

5"

7"

CEILING REPAIR - PARTIAL DEPTH (P/T)

4.1

FLOOR REPAIR - SLAB EDGE

3.8.1

6"

VARIES

(NOTE 2)

SAWCUT PATCH

PERIMETER 3/4"

(TYP.)

REMOVE AND REPLACE CONCRETE

WITHIN SECTION SHOWN. PROVIDE

RADIUS AND SLOPE TO MATCH

EXISTING.

EXIST P/T STRUCTURAL SLAB

(REINFORCEMENT NOT SHOWN)

REINFORCEMENT (TYP),

LOCATIONS APPROXIMATE. CLEAN

AND APPLY CORROSION INHIBITOR

TO ALL EXPOSED REINF. PROVIDE

3/4" CLEARANCE AROUND ALL

EXPOSED REINF. WHERE REQ'D AS

SPECIFIED IN SECTION "SURFACE

PREPARATION FOR PATCHING".

FLOOR REPAIR - CONCRETE CURB REPAIR

3.4

REPAIR CONCRETE SEE W.I. 3.0

EXIST CONC CURB

NOTES:

1. TOOL AND SEAL CONTROL JOINTS PER

WORK ITEM 11.4 TO MATCH EXISTING.

2. CONCRETE REMOVALS EXTENDING

FURTHER THAN 1 FT FROM THE VERTICAL

CURB FACE SHALL BE PAID UNDER W.I. 3.1B.

3" MIN.

(TYP.)

VARIES

5"

7"

SAW CUT PATCH

PERIMETER 3/4"

(TYP.) SEE NOTE 1.

EXISTING PT

STRUCTURAL SLAB

GRIND OR SAW CUT

PATCH PERIMETER

1/2" (TYP.)

REINFORCEMENT (TYP.), LOCATIONS APPROXIMATE.

CLEAN AND EPOXY COAT ALL EXPOSED REINF. PROVIDE

3/4" CLEARANCE AROUND ALL EXPOSED REINF. WHERE

REQ'D AS SPECIFIED IN SECTION "SURFACE

PREPARATION FOR PATCHING".

EXISTING VOID. SEE NOTE 5.

FORMING BY CONTRACTOR

(INCIDENTAL)

ORIGINAL

SURFACE

NOTES:

1. CAUTION, SLAB CONTAINS P/T TENDONS AND ANCHORAGE HARDWARE, DO NOT CUT OR DAMAGE.

IDENTIFY TENDON LOCATIONS PRIOR TO SAW CUTTING REPAIR PERIMETER.

2. THIS REPAIR OCCURS AT SOUND AND UNSOUND CONCRETE AREAS, AS NEEDED TO FACILITATE WI

SERIES 21.0 REPAIRS.

3. REFER TO WORK ITEMS 3.1B OR 3.4 FOR EXISTING CONCRETE OVERLAY OR CURB REMOVAL.

(EXISTING OVERLAY OR CURB NOT SHOWN).

4. WHERE P/T FULL DEPTH REPAIR OCCURS IN AN AREA WITHOUT AN OVERLAY OR CURB, TOOL AND

SEAL REPAIR PERIMETER PER WORK ITEM 11.4. WHERE P/T FULL DEPTH REPAIR OCCURS BENEATH

AN OVERLAY OR CURB, DO NOT TOOL AND SEAL REPAIR PERIMETER.

5. CONTRACTOR SHALL PLACE CONTROLLED LOW-STRENGTH MATERIAL TO COMPLETELY FILL ANY

EXISTING VOIDS IMMEDIATELY UNDER WORK ITEM 3.3B REPAIR AREAS PER WORK ITEM 3.14.

P/T TENDON,

LOCATION

VARIES

FLOOR REPAIR - FULL DEPTH (P/T) - UPPER LEVEL

3.3A

PERFORM REMOVALS

ANGLED INWARD AS

SHOWN (TYP).

NOTE 4

FLOOR REPAIR - FULL DEPTH (P/T) - LOWER LEVEL

3.3B

AT

L

O W

ER

O

R U

PP

ER

L

EV

EL

S

AT

L

O W

ER

L

EV

EL

O N

LY

REMOVE AND REPLACE CONCRETE

WITHIN SECTION SHOWN SHADED

REMOVAL

LIMITS (TYP.)

CONTROLLED LOW-STRENGTH MATERIAL -

LOWER LEVEL

3.14

REMOVE AND

REPLACE

CONCRETE

WITHIN

SECTIONS

SHOWN

SHADED (TYP.)

REMOVAL

LIMITS (TYP.)

SPALL OR

DELAMINATION (TYP.)

EXISTING REINFORCEMENT

(TYP.) ACTUAL SIZE AND

LOCATION MAY DIFFER

FROM THAT SHOWN. CLEAN

AND EPOXY COAT ALL

EXPOSED REINF. PROVIDE

3/4" CLEARANCE AROUND

ALL EXPOSED REINF.

WHERE REQ'D AS

SPECIFIED IN SECTION

SURFACE PREPARATION

FOR PATCHING AND

OVERLAY".

GRIND OR SAWCUT PATCH

PERIMETER 3 4" (TYP.)

±3"-5"

(TYP.)

VI

F)

VARIES

NOTES:

1. COORDINATE SLAB EDGE REPAIRS WITH OTHER CONCRETE

SLAB REPAIRS.

2. LOCATE EMBEDDED P/T ELEMENTS PRIOR TO START OF WORK.

3. SLAB EDGE REPAIRS TYPICALLY OCCUR NEAR CONCRETE

RAILINGS WITH STEEL INFILLS (NOT SHOWN FLOR CLARITY).

RAILING FEATURES MAY MAKE SLAB EDGE REPAIR AREAS

DIFFICULT TO ACCESS. CONTRACTOR TO WORK AROUND

EXISTING CONCRETE RAILINGS AND INFILLS. DO NOT DAMAGE

EXISTING FEATURES. REFER TO DETAIL 3.8.1 FOR REFERENCE.

POST-TENSIONED

SLAB. DO NOT

DAMAGE EMBEDDED

REINFORCEMENT

(NOT SHOWN). SEE

CAUTION NOTE

BELOW

FLOOR REPAIR - SLAB EDGE

3.8

VARIES

TOP OF

SLAB

REMOVALS IN THIS AREA

PAID UNDER OTHER W.I.

SERIES 3.0 WORK

CAUTION NOTE: THE FLOOR SLAB HAS POST-TENSIONING TENDONS. THESE

TENDONS ARE NEAR THE FLOOR SURFACE AT SPALLS AND DELAMINATIONS.

THE CONTRACTOR SHALL EXERCISE EXTREME CAUTION WHEN SAW-CUTTING

SO AS NOT TO DAMAGE EXISTING TENDONS OR TENDON SHEATHS. TENDONS

MAY BREAK WITH EXPLOSIVE FORCE WHEN CUT. CHIPPING WITH 15 LB

HAMMERS SHALL BE USED IN LIEU OF SAW-CUTTING NEAR SHALLOW TENDONS.

PAY UNIT

PAY UNIT

PA

Y

U N

IT DEPTH OF REMOVAL

FOR THIS WORK

ITEM. NO DOUBLE

PAY FOR CORNERS.

REMOVALS IN THIS AREA PAID

UNDER W.I. SERIES 4.0.

NOTE 3

(FOR REFERENCE ONLY)

TOP OF

FLOOR

SLAB

EXIST CONCRETE

RAILING WITH

STEEL INFILLS

UPPER LEVEL RAILINGS

3"-5" DEPTH

PA

Y

U N

IT

VA

R

IE

S 3"

-5

D

EP

TH

PA

Y

U N

IT

VA

R

IE

S

3"-5"

DEPTH

PAY UNIT

VARIES

2'-0"

REMOVE AND REPLACE

CONCRETE WITHIN

SECTIONS SHOWN

SHADED (TYP.)

REINFORCEMENT (TYP.), LOCATIONS

APPROXIMATE. CLEAN AND EPOXY

COAT ALL EXPOSED REINF. PROVIDE

3/4" CLEARANCE AROUND ALL

EXPOSED REINF. WHERE REQ'D AS

SPECIFIED IN SECTION "SURFACE

PREPARATION FOR PATCHING".

GRIND OR SAWCUT

PATCH PERIMETER 1/2"

(TYP.)

REMOVAL LIMITS (TYP.)

SPALL OR DELAMINATION (TYP.)

P/T TENDONS, NUMBER AND

LOCATION VARIES (NOTE 3)

BEAM REPAIR - PARTIAL DEPTH

(P/T) - UPPER LEVEL

5.1

NOTES:

1. CONTRACTOR DOES NOT GET PAID DOUBLE AT CORNERS.

2. VERIFY LOCATION OF REPAIRS IN FIELD WITH ENGINEER.

3. CAUTION, BEAM CONTAINS P/T TENDONS AND ANCHORAGE HARDWARE, DO NOT CUT OR

DAMAGE. IDENTIFY TENDON LOCATIONS PRIOR TO SAWCUTTING REPAIR PERIMETER.

2"-4"

VA

R

IE

S

2"-4"

VA

R

IE

S

GRIND OR SAWCUT

PATCH PERIMETER

3/4" (TYP)

REMOVE AND REPLACE

CONCRETE WITHIN

SECTION SHOWN

SHADED (TYP)

SPALL OR

DELAMINATION

(TYP)

REINFORCEMENT (TYP),

LOCATIONS APPROXIMATE.

CLEAN AND APPLY CORROSION

INHIBITOR TO ALL EXPOSED

REINF. PROVIDE 3/4"

CLEARANCE AROUND ALL

EXPOSED REINF. WHERE REQ'D

AS SPECIFIED IN SECTION

"SURFACE PREPARATION FOR

PATCHING".

REMOVAL LIMITS

NOTES:

1. COLUMN TIES WHICH HAVE LOST MORE THAN 15% OF ORIGINAL CROSS SECTIONAL AREA SHALL

BE SUPPLEMENTED AS ENGINEER DIRECTS.

2. NUMBER AND LOCATION OF REINFORCEMENT SHOWN MAY DIFFER FROM ACTUAL FIELD

CONDITIONS.

COLUMN REPAIR-PARTIAL DEPTH

6.1

R-501

REPAIR

DETAILS

SHEET TITLE:

D

ES

C R

IP

TI

O N

IS

SU

E:

M

AR

K D

AT

E

PROJECT NO:

DRAWN BY:

CHECKED BY:

20-002368.00

Copyright 2023. All rights reserved. No part of this document may be reproduced in any form or by any means without permission from Walker Consultants

J:

\M

IC

H

IG

AN

\2 0-

-0

0-

PO

R T_

H U

R O

N _M

O C

_P S_

_R

PR

S\ D

R

AW

IN

G

S\

R

-5

S

ER

IE

S.

D W

G

/1 4/

2:

:0

PM

W

YL

IE

, K

EV

IN

C O

N S

U L

T A

N T

S W A L K E R

Av is

D riv e Su ite

An n

Ar bo r, M

I 4

4.

3.

P h w w w

.w al ke rc on su lta nt s.

co m

M

IC

H

IG

AN

PA

R

KI

N

G S

TR

U

C

TU

R E

R

EP

AI

R

S

C

IT

Y O

F

PO

R T

H U

R O

N

PO

RT

H

UR

ON

ECC

EK

BI

D

D

IN

G A

N D

C O

N

ST

R U

C

TI

O N

/2

3/

3/ 4"

ROUT CRACK WITH 'V' BLADE

AND FILL WITH FLEXIBLE

SEALANT. INSTALL SEALANT

FLUSH WITH ADJACENT

SURFACES. (NOTE 1)

DO NOT OVERFILL JOINT.

EXISTING CONCRETE

ROUT AND SEAL RANDOM CRACKS

11.1

EXISTING CRACK. CENTER

ROUTED GROOVE ON CRACK

NOTES:

1. PROVIDE CONCAVE SEALANT SURFACE

PROFILE IN AREAS NOT RECEIVING

TRAFFIC COATING PER W.I. SERIES 16.0.

PROVIDE 1/16" DEPTH AT VERTEX OF

CONCAVE PROFILE.

3/ 4"

3/4"

EXIST WALL, COLUMN,

OR CURB FACE

EXIST FINISHED FLOOR

SURFACE

SEALANT MATERIAL

1/2" MIN THROAT

SEE NOTE 1.

COVE SEALANT

11.7

NOTE:

1. REMOVE EXISTING COVE SEALANT MATERIAL IF PRESENT. PREPARE SURFACE PER

SPECIFICATIONS.

2. TYPICAL AT UPPER LEVEL. REMOVAL OF EXISTING WATERPROOFING MEMBRANE

TO REPLACE EXISTING COVE SEALANTS IS INCIDENTAL. REPAIR EXISTING

WATERPROOFING MEMBRANE AFTER INSTALLATION OF NEW SEALANT PER WORK

ITEM 16.0 SERIES.

EXIST WATERPROOFING

MEMBRANE (NOTE 2)

VARIES4" 4"

AFTER REMOVING ALL LOOSE MEMBRANE,

GRIND EXIST TRAFFIC MEMBRANE AT

PERIMETER OF PATCH AREA FLUSH WITH

EXIST CONCRETE SUBSTRATE (TYP)

TRAFFIC TOPPING

PATCH (TYP)

EXIST TRAFFIC

TOPPING (TYP)

EXIST FLOOR SLAB

NOTE:

1. COORDINATE TRAFFIC COATING REPAIR WITH WORK ITEMS 16.4A AND 16.4B.

4"MIN

EXIST MEMBRANE

TO REMAIN

REPAIR AREA

REMOVE LOOSE MEMBRANE

(FOR REFERENCE ONLY)

16.3

(INCIDENTAL)

TRAFFIC COATING REPAIR

3/4"

3/ 4"

REMOVE ALL EXISTING SEALANT,

PREPARE SUBSTRATE, AND FILL WITH

FLEXIBLE SEALANT. INSTALL SEALANT

FLUSH WITH ADJACENT SURFACE.

(NOTE 1) DO NOT OVERFILL JOINT.

BOND BREAKER TO

SEPARATE SEALANT

FROM CONCRETE AT

BOTTOM OF JOINT EXIST CRACK

REPLACE CRACK/JOINT SEALANT

11.2

EXIST CONCRETE

3/8"

±1 1/2"

1/ 2"

REMOVE EXISTING SEALANT

USING METHOD THAT DOES

NOT WIDEN JOINT, PREPARE

SUBSTRATE, AND FILL WITH

FLEXIBLE SEALANT. INSTALL

SEALANT EVENLY FLUSH WITH

SURFACE. (NOTE 1) DO NOT

OVERFILL JOINT.

CLOSED CELL BACKER

ROD. BACKER ROD

SHALL BE 25% LARGER

THAN JOINT WIDTH.

EXISTING JOINT

11 2'

VI

F (N

O

TE

2" VIF

(NOTES 3 & 4)

REMOVE SEALANT. PREPARE

SUBSTRATE AND FILL WITH FLEXIBLE

SEALANT. INSTALL SEALANT EVENLY

TOOL FLUSH WITH SURFACE (NOTE 1)

DO NOT OVERFILL JOINT.

EXIST CONCRETE

TOOL AND SEAL CONTROL JOINTS

11.4

(INCIDENTAL)

SECTION AT PREVIOUSLY SEALED CRACKING

NOTES:

1. PROVIDE CONCAVE SEALANT SURFACE PROFILE IN AREAS NOT RECEIVING TRAFFIC COATING

PER W.I. SERIES 16.0. PROVIDE 1/16" DEPTH AT VERTEX OF CONCAVE PROFILE.

2. EXCLUDES ISOLATION JOINTS WHERE EXPANSION JOINTS ARE INSTALLED OR ARE BEING

INSTALLED PER W.I. SERIES' 9.0 & 10.0.

3. W.I. 11.4: TOOL AND SEAL JOINTS THROUGH REPAIR CONCRETE TO MATCH EXISTING

(INCIDENTAL TO W.I. SERIES 3.0). PROVIDE BACKER ROD (AS NEEDED) AND SEALANT TO

PROVIDE PROFILE SHOWN DETAILED.

4. W.I. 11.4: WHEN TOOLING AND SEALING JOINTS AT NEW PATCH PERIMETERS (INCIDENTAL TO W.I.

SERIES 3.0), PROVIDE A JOINT PROFILE TO MATCH EXISTING. DO NOT INSTALL BACKER ROD.

5. W.I. 11.4: CONTROL JOINT MUST BE TOOLED IN PLASTIC CONCRETE AND DIMENSIONS AS

DETAILED BE MAINTAINED IN SET CONCRETE. SAWCUTTING OF CONTROL JOINT IN HARDENED

CONCRETE WILL NOT BE PERMITTED.

EXIST CONC

STRUCTURE

(CURB, WALL,

ETC.)

1"EXIST CONCRETE

SECTION AT ISOLATION BETWEEN ADJACENT

STRUCTURAL ELEMENTS (NOTE 2)

AT CONTROL JOINTS (NOTES 3, 4, & 5)

1/ 2"

1"

CLOSED CELL BACKER

ROD, AS NEEDED, SIZED

TO PROVIDE SEALANT

PROFILE SHOWN.

TRAFFIC COATING - RECOAT (STANDARD)

16.4A

PROVIDE 4" WIDE DETAIL

COAT CENTERED OVER

ALL CRACKS LESS THAN

1/32" WIDE

5"

- 7

VI

F) 6"

(V

IF

ROUT AND SEAL CRACKS

GREATER THAN 1/32"

WIDTH. PROVIDE 4" DETAIL

COAT CENTERED OVER

ALL SEALED CRACKS/

JOINTS. SEE DETAIL 11.1.

COVE SEALANT

SEE DETAIL 11.7

EXISTING CONCRETE

OVERLAY

EXISTING STRUCTURAL

SLAB

CONTRACTOR TO PROVIDE

STRAIGHT FINISHED LINE.

LIMITS OF SURFACE PREPARATION

4" 2"

SLAB EDGE (ON EAST

SIDE) SEE NOTE 2.

NEW TRAFFIC COATING

PER W.I. 16.4A OR 16.4B

VERTICAL SURFACE (WALL, COLUMN, BARRIER PEDESTAL,

LIGHT POLE FOUNDATION, ETC WITHIN WORK AREA)

NOTES:

1. ALL VERTICAL DETAILING & ADDITIONAL DETAIL OVER CRACKS/JOINTS IS INCIDENTAL TO THIS WORK.

2. EXTEND TRAFFIC TOPPING DOWN THE SIDE OF SLAB EDGE TO BOTTOM OF BEAM AND SLAB EDGE

ALONG THE EAST PERIMETER OF THE WORK AREA AS SHOWN (INCIDENTAL).

TRAFFIC COATING - RECOAT (KELMAR)

16.4B

EXISTING TRAFFIC COATING.

REPAIR TRAFFIC COATING

SYSTEM PER WORK ITEM

16.3. (TYP)

VERTICAL SURFACE

(WALL OR COLUMNS)

LIMITS OF SURFACE

PREPARATION

CONTRACTOR TO PROVIDE

STRAIGHT FINISHED LINE

PROVIDE 4" WIDE DETAIL

COAT CENTERED OVER

ALL CRACKS LESS THAN

1/32" WIDE

TRAFFIC TOPPING

(FLOOR SURFACE

OR CURB)

ROUT AND SEAL CRACKS GREATER

THAN 1/32" WIDTH. REMOVE AND

REPLACE ALL EXIST CRACK/JOINT

SEALANT. SEE DETAILS 11.1 OR 11.2.

COVE SEALANT.

SEE DETAIL 11.7

NEW COATING (STANDARD)

16.1

NOTE:

1. QUANTITIES BASED ON HORIZONTAL APPLICATION AREA. VERTICAL DETAILING AND ADDITIONAL

DETAIL COAT OVER CRACKS ARE INCIDENTAL TO THIS WORK.

ISOMETRIC

TRAFFIC COATING -

4"

2"

CRACKS < 1/32" CRACKS > 1/32"

(OR MOVING CRACKS)

HORIZ / VERT

TRANSITION

PROVIDE 4" WIDE DETAIL

COAT CENTERED OVER

CRACK

R-502

REPAIR

DETAILS

SHEET TITLE:

D

ES

C R

IP

TI

O N

IS

SU

E:

M

AR

K D

AT

E

PROJECT NO:

DRAWN BY:

CHECKED BY:

20-002368.00

Copyright 2023. All rights reserved. No part of this document may be reproduced in any form or by any means without permission from Walker Consultants

J:

\M

IC

H

IG

AN

\2 0-

-0

0-

PO

R T_

H U

R O

N _M

O C

_P S_

_R

PR

S\ D

R

AW

IN

G

S\

R

-5

S

ER

IE

S.

D W

G

/1 4/

2:

:0

PM

W

YL

IE

, K

EV

IN

C O

N S

U L

T A

N T

S W A L K E R

Av is

D riv e Su ite

An n

Ar bo r, M

I 4

4.

3.

P h w w w

.w al ke rc on su lta nt s.

co m

M

IC

H

IG

AN

PA

R

KI

N

G S

TR

U

C

TU

R E

R

EP

AI

R

S

C

IT

Y O

F

PO

R T

H U

R O

N

PO

RT

H

UR

ON

ECC

EK

BI

D

D

IN

G A

N D

C O

N

ST

R U

C

TI

O N

/2

3/

C D

ZONE ZONE

E

ZONE

ZONE

C.J.

CASE

#2A

CASE #3A & 3B

INTERMEDIATE

STRESSING

ANCHOR

CASE #3C &

3D

END

ANCHOR

(TYP.)

CASE

#4A & 4B

P/T SLAB SECTION WITH TYPICAL TENDON

FAILURE CONDITIONS AND REPAIR SCENARIOS

21.0

ZONE II - TENDON REPAIR @ SLAB SOFFIT

CASE 2A:

A. DOUBLE COUPLING AND TENDON SPLICE

REPAIR. B. SEE DETAIL 21.8.1, SIM.

ZONE III - TENDON REPAIR OVER BEAMS

CASE 3A:

A. DOUBLE COUPLING AND TENDON SPLICE REPAIR.

B. SEE DETAIL SERIES 21.8.

CASE 3B:

A. SINGLE COUPLING TENDON SPLICE WITH

CENTER-PULL TENDON SPLICE COUPLING.

B. SEE DETAIL SERIES 21.6 & 21.7.

CASE 3C:

A. SINGLE COUPLING TENDON SPLICE WITH

CENTER-PULL TENDON SPLICE COUPLING. (KEEP

INTERMEDIATE ANCHOR)

B. SEE DETAIL SERIES 21.6, & 21.7. B.

CASE 3D:

A. SINGLE COUPLING TENDON SPLICE WITH

CENTER-PULL TENDON SPLICE COUPLING.

(REMOVE INTERMEDIATE ANCHOR)

B. SEE DETAIL SERIES 21.6 & 21.7.

ZONE IV - END ANCHOR REPAIR AT WALL/BEAM

CASE 4A:

A. ABANDON & MOVE END ANCHOR LOCATION @

WALL/BEAM (LIVE).

B. SEE DETAIL SERIES 21.3.

CASE 4B:

A. ABANDON & MOVE END ANCHOR LOCATION @

WALL/BEAM (DEAD).

B. SEE DETAIL SERIES 21.4.

CASE 4E:

A. ABANDON & MOVE END ANCHOR LOCATION @

BEAM (LIVE).

B. SEE DETAIL SERIES 21.3.

CASE 4F:

A. ABANDON & MOVE END ANCHOR LOCATION @

BEAM (DEAD).

B. SEE DETAIL SERIES 21.4..

NOTES:

1. TYPICAL CONCRETE DELAMINATIONS SHOWN IN SHADED AREA ABOVE, FOR

REFERENCE ONLY. ACTUAL REPAIR LOCATIONS WILL BE DETERMINED IN FIELD BY

CONTRACTOR AND ENGINEER.

2. SECTION ABOVE SHOWS TYPICAL P/T TENDON FAILURE AREAS ("ZONES") .

CORRESPONDING REPAIR SCENARIOS ("CASES") ARE DESCRIBED ABOVE AND

ASSOCIATED REPAIR DETAILS ARE REFERENCED.

3. A COMBINATION OF REPAIR "CASES" MAY BE REQUIRED TO REPAIR A TENDON

DEPENDING ON LOCATION AND NUMBER OF FAILURES ALONG A TENDON RUN.

4. SEE "P/T REPAIR GENERAL NOTES" FOR FURTHER REQUIREMENTS.

CASE #4E

& 4F

PRE-COMPRESSION ZONE (SEE NOTE 1)

SH

O

R

IN

G (N

O

TE

SH

O

R

IN

G (N

O

TE

EXIST. REINF. (TYP.)

E.J. OR

SLAB EDGE

EXIST. SLAB

SURFACE

EXIST. P/T TENDON TYPICAL CONCRETE

REMOVAL AREA SHOWN

SHADED

CONCRETE REMOVALS AT P/T CABLE

21.0.1

NOTES:

1. "PRE-COMPRESSION ZONE" REFERS TO THE AREA OF SLAB THAT CONTAINS THE P/T TENDONS WITHIN THE TOP HALF OF THE

SLAB.

2. CONTRACTOR RESPONSIBLE FOR INSTALLING SHORING TO MAINTAIN STABILITY OF SLAB DURING CONCRETE REMOVALS WITHIN

"PRE-COMPRESSION ZONE". AS A MINIMUM, CONTRACTOR SHALL INSTALL SHORING WHEN LENGTH OF REMOVAL TRANSVERSE TO P/T TENDONS EXCEEDS 5 FEET. DETENSIONING MAY ALSO BE REQUIRED PRIOR TO REMOVALS. SUBMIT DETENSIONING PLAN

FOR ENGINEER REVIEW.

A

A

16" MIN

2"-4"

(TYP)

5"

7" N

O M

IN

AL

45° MAX

TYPICAL

DELAMINATION.

P/T END ANCHOR PLATE (TYP). SINGLE

OR MULTIPLE ANCHORS PER RUN.

FACE OF EJ, CJ, OR SLAB END.

REMOVE AND REPLACE CONCRETE

FROM AROUND P/T ANCHOR PLATE

WITHIN SECTION SHOWN SHADED.

FACE OF EJ, CJ, OR

SLAB END.

REMOVAL LIMIT (TYP)

P/T TENDON (TYP)

INSPECT P/T TENDONS

21.1

ISOMETRIC

SECTION

NOTE:

1. USE EXTREME CAUTION REMOVING CONCRETE AROUND TENDON ANCHOR. MAXIMUM

15# CHIPPING HAMMERS SHALL BE USED IN REMOVING CONCRETE. MULTIPLE/BUNDLED

TENDONS WILL REQUIRE LARGER INSPECTION REMOVAL.

2" 2" DAMAGED SHEATHING

(VARIES)

2" 2"

EXIST. TENDON

& SHEATHING

EXIST. P/T

SLAB OR BEAM

LIMIT OF

REMOVAL (TYP.)

INSTALL HIGH DENSITY

POLYPROPYLENE SHEATHING. EXTEND

2" BEYOND DAMAGED AREA

APPLY TWO LAYERS OF TAPE OVER ENTIRE

LENGTH OF NEW SHEATHING. EXTEND TAPE

2" ONTO EXIST. SHEATHING

REMOVE DAMAGED

SHEATHING, AND GREASE &

WRAP EXPOSED TENDON.

APPLY EPOXY PAINT IN LIEU

OF GREASE, ONLY AS

DIRECTED BY ENGINEER. PLAN VIEW

RECAST CONC. PER

WORK ITEM SERIES 3.0

PROTECT EXPOSED P/T TENDONS

21.2

(INCIDENTAL)

SIDE "B" SIDE "A"

1' -4

O

N E

TE

N

D O

N

2' -0

TW

O T

EN

D

O N

S)

2" CL.

(2) #4 EA SIDE, EQUALLY SPACED.

EMBED 6" INTO EXIST SLAB

(MID-DEPTH) LAP 1'-0" MIN w/

ADJACENT BAR. ANCHOR WITH

EPOXY ADHESIVE

ORIGINAL END

ANCHOR

LOCATION (TYP).

REMOVE END

ANCHOR

(2) #4 TOP & BOT (w/ STD HOOKS

AT BOT BARS TYP)

EXIST CONCRETE

#4 w/ STD HOOK

1'-4" LAP MIN (TYP)

NOTE 2 (TYP.)

NEW REPOSITIONED

END ANCHOR (TYP)

EXISTING P/T

TENDON (TYP)

21.3.1

P/T TENDON END ANCHORAGE (LIVE)

21.3

PARTIAL FLOOR PLAN

NOTES:

1. THIS DETAIL TYPICALLY APPLIES WHEN A TENDON FAILURE OCCURS NEAR THE EXISTING END

ANCHOR. SEE DETAIL 21.3.1 FOR ADDITIONAL INFORMATION.

2. IF NECESSARY, PULL TENDON INTO SIDE 'B' TO PROVIDE TAIL FOR STRESSING. (MAKE

ADJUSTMENT AT TENDON SPLICE REPAIR LOCATION).

3. DEPENDING ON EXTENT OF TENDON DAMAGE, THIS REPAIR MAY NEED TO BE PERFORMED IN

COMBINATION WITH OTHER TENDON REPAIRS.

REPAIR CONCRETE

SEE W.I. 3.0 SERIES

5" -7

N

O M

IM

AL

2'-0" 1'-6"

(W.I. 3.3)

(SIDE "B") (SIDE "A")

NEW REPOSITIONED

END ANCHOR

E.J., C.J., OR

SLAB END

ORIGINAL END

ANCHOR LOCATION.

REMOVE END

ANCHOR.

TENDON FAILURE LOCATION (TYP)

REMOVE AND REPLACE CONC. FULL

DEPTH WITHIN SECTIONS SHOWN

SHADED. REPAIR CONC. SEE W.I. 3.0

SERIES.

#4 (TYP)

#4 w/STD. HOOK. PLACE (1) TOP &

(1) BOT. BEHIND ANCHOR PLATE.

EMBED 6" INTO EXIST. SLAB.

ANCHOR WITH EPOXY ADHESIVE

EXIST. P/T SLAB

TOOLED JOINT.

SEE DETAIL 11.4

WORK SEQUENCE NOTES:

P/T TENDON END ANCHORAGE (LIVE)

21.3.1

1. VERIFY TENDON FULLY DETENSIONED

2. REPLACE CONCRETE FULL DEPTH PER W.I. 3.3.

3. INSTALL NEW END ANCHOR AND REINFORCEMENT.

4. PLACE CONCRETE IN SIDE 'A'. ALLOW ADEQUATE

CONC. STRENGTH GAIN.

5. STRESS P/T TENDON.

6. PLACE CONCRETE IN SIDE 'B'.

PARTIAL FLOOR SECTION

2'-0" MAX. 1'-6"

2" CL.

1' -4

O

N E

TE

N

D O

N

2' -0

TW

O T

EN

D

O N

S)

#4 ALTERNATE SIDES @ 6" O.C.

EMBED 6" INTO EXIST. SLAB @

MID-DEPTH. ANCHOR WITH

EPOXY ADHESIVE.

SLAB

END

ORIGINAL END

ANCHOR LOCATION.

REMOVE END

ANCHOR.

NEW REPOSITIONED

END ANCHOR. SEE

NOTES 2 & 3.

EXISTING P/T

TENDON (TYP.)

EXIST. CONCRETE

(2) #4. EMBED 6" INTO EXIST. SLAB @

MID-DEPTH. ANCHOR WITH EPOXY ADHESIVE.

(2) #4 TOP & BOT. EMBED 6" INTO EXIST. SLAB

(MID-DEPTH). ANCHOR WITH EPOXY ADHESIVE.

21.4.1

P/T TENDON END ANCHORAGE (DEAD)

21.4

NOTES:

1. THIS DETAIL TYPICALLY APPLIES WHEN A TENDON FAILURE OCCURS NEAR AN EXISTING

END ANCHOR AND STRESSING OF THE TENDON WILL OCCUR AT A DIFFERENT LOCATION

AS DETERMINED BY ENGINEER. SEE DETAIL 21.4.1 FOR ADDITIONAL INFORMATION.

2. DEPENDING ON EXTENT OF TENDON DAMAGE, THIS REPAIR WILL BE PERFORMED IN

COMBINATION WITH EITHER W.I. 21.3 OR W.I. 21.6 FOR STRESSING OF THE TENDON.

3. IF THIS REPAIR IS PERFORMED IN COMBINATION WITH A CENTER-PULL SPLICE (W.I. 21.6)

REPAIR, THEN PULL TENDON BACK TO ALLOW ANCHOR INSTALLATION AT ORIGINAL

LOCATION (W.I. 21.8).

PARTIAL FLOOR PLAN

REPAIR CONCRETE

SEE W.I. 3.0 SERIES.

5" -7

N

O M

IN

AL

2'-0" 1'-6"

W.I. 3.3

NEW REPOSITIONED

END ANCHOR. SEE NOTE

3 ON DETAIL 21.4.

EJ, CJ, SLAB END OR

EDGE OF POURSTRIP

ORIGINAL END ANCHOR

TO BE REMOVED

EXISTING P/T

SLAB

(2) #4 - PLACE (1) TOP AND (1) BOT

BEHIND ANCHOR PLATE. EMBED 6"

INTO EXISTING SLAB AND ANCHOR

WITH EPOXY ADHESIVE.

#4 (TYP) (T & B)

REMOVE AND REPLACE CONCRETE

FULL DEPTH WITHIN SECTIONS

SHOWN SHADED. REPLACE CONC

PER W.I. 3.0 SERIES.

TENDON FAILURE LOCATION

(TYP)

WORK SEQUENCE NOTES:

P/T TENDON END ANCHORAGE (DEAD)

21.4.1

1. VERIFY TENDON FULLY DETENSIONED.

2. REMOVE CONCRETE FULL DEPTH PER WORK ITEM 3.3.

3. INSTALL NEW END ANCHOR AND REINFORCEMENT.

4. PLACE CONCRETE. ALLOW ADEQUATE CONCRETE STRENGTH GAIN.

5. STRESS P/T TENDON. (NOT INCLUDED IN WORK ITEM 21.4).

6. STRESSING OCCURS AT LIVE END (WORK ITEM 21.3) OR AT CENTER-PULL COUPLING (WORK ITEM 21.6).

PARTIAL FLOOR SECTION

5" -7

REMOVE CONCRETE

IN SECTION SHOWN

P/T TENDON

PROVIDE VARIOUS SIZED EPOXY

COATED BAR x 6" LONG. (NOTE 1)

CONCRETE REMOVALS AT P/T CABLE

21.0.2

NOTE:

1. WHEN PERFORMING CONCRETE REMOVALS ALONG P/T TENDON, PROVIDE TENDON

SUPPORTS AS SHOWN AT 2'-0" OC MAXIMUM TO MAINTAIN TENDON PROFILE.

R-503

REPAIR

DETAILS

SHEET TITLE:

D

ES

C R

IP

TI

O N

IS

SU

E:

M

AR

K D

AT

E

PROJECT NO:

DRAWN BY:

CHECKED BY:

20-002368.00

Copyright 2023. All rights reserved. No part of this document may be reproduced in any form or by any means without permission from Walker Consultants

J:

\M

IC

H

IG

AN

\2 0-

-0

0-

PO

R T_

H U

R O

N _M

O C

_P S_

_R

PR

S\ D

R

AW

IN

G

S\

R

-5

S

ER

IE

S.

D W

G

/1 4/

2:

:0

PM

W

YL

IE

, K

EV

IN

C O

N S

U L

T A

N T

S W A L K E R

Av is

D riv e Su ite

An n

Ar bo r, M

I 4

4.

3.

P h w w w

.w al ke rc on su lta nt s.

co m

M

IC

H

IG

AN

PA

R

KI

N

G S

TR

U

C

TU

R E

R

EP

AI

R

S

C

IT

Y O

F

PO

R T

H U

R O

N

PO

RT

H

UR

ON

ECC

EK

BI

D

D

IN

G A

N D

C O

N

ST

R U

C

TI

O N

/2

3/

1' -6

3'-0" MIN. (NOTE 2)

(RUST-FREE TENDON)

1'-6" MIN.

(NOTE 2)

(RUST-FREE

TENDON)

GRID

CENTER-PULL TENDON SPLICE COUPLER

(1) OR (2) TENDONS PER RUN TYP.

(STAGGER SPLICE COUPLERS AS

REQ'D. IF BOTH TENDONS REQUIRE

REPAIR) EXIST. P/T TENDON

BEAM BELOW

REMOVAL LIMIT (NOTE 3)

EXIST. P/T TENDON (TYP.)

NEW P/T TENDON & COUPLING

PER W.I. 21.7 (NOTE 5)

21.6.1

TENDON SPLICE COUPLING (CENTER-PULL)

TENDON SPLICE COUPLING (SINGLE)

21.721.6

21.6.2

21.7.1

21.7.2

NOTES:

1. SEE DETAILS SERIES 21.6.1, 21.6.2, 21.7.1, AND 21.7.2 FOR ADDITIONAL INFORMATION.

2. INCREASE CONCRETE REMOVAL LENGTH AS REQ'D BY STRESSING AND INSTALLATION METHODS.

3. STAGGER SPLICE COUPLERS IF MORE THAN (1) TENDON PER RUN REQUIRES REPAIR. ALTERNATE CENTER-PULL

COUPLERS ON OPPOSITE SIDES OF GRID LINE.

4. LOCATE SPLICE COUPLINGS ALONG EXIST. TENDON PROFILE AT SLAB MID-DEPTH.

5. NEW TENDON LENGTH BEYOND 10'-0" SHALL BE PAID FOR UNDER W.I. 21.9.

PARTIAL FLOOR PLAN

REPAIR CONC.

SEE W.I. 3.0 SERIES.

GRID

5"

7"

BROKEN OR

PREVIOUSLY CUT P/T

TENDON

EXIST. P/T

TENDON

CENTER-PULL TENDON

SPLICE COUPLING PER

W.I. 21.6

EXIST. TENDON

REMOVE AND REPLACE CONC. IN

SECTION SHOWN SHADED. REPLACE

FULL DEPTH AT COUPLING (TYP.).

EXIST.

BEAM

EXIST. P/T TENDON

REMOVAL LIMITS

(TYP.)

SAW CUT PATCH

PERIMETER 3/4"

(TYP.)

NEW P/T TENDON &

COUPLING PER W.I. 21.7

EXISTING

BEAM

EXISTING

SLAB

EXISTING FLOOR

DELAMINATION

TENDON SPLICE COUPLING OVER BEAM

21.6.1 21.7.1

1" C

LR

(M

IN

1" C

LR

(M

IN

EXISTING SECTION

REPAIR SECTION

NOTES:

1. SEE DETAILS 21.6 AND 21.7 FOR REMAINING INFORMATION.

2. MAINTAIN ORIGINAL TENDON PROFILE.

REPAIR CONC.

SEE W.I. 3.0 SERIES.

5" -7

C.J. AS REQ'D BY P/T

CONTRACTOR

(INTERMEDIATE ANCHOR TO REMAIN)

C.J.

INTERMEDIATE P/T

ANCHOR PLATE

P/T TENDON(S) [SINGLE OR MULTIPLE

TENDONS PER RUN TYP.]

BROKEN TENDON

TENDON REMAINS IN

TENSION

REMOVE AND REPLACE CONC. IN

SECTION SHOWN SHADED.

REPLACE FULL DEPTH AT

CENTER-PULL COUPLING.

3/4" SAWCUT (TYP.)

NEW P/T TENDON &

COUPLING PER W.I. 21.7

REMOVAL LIMIT (TYP.)

CENTER-PULL TENDON SPLICE

COUPLING PER W.I. 21.6

P/T TENDON(S) [SINGLE OR MULTIPLE

TENDONS PER RUN TYP.]

TENDON SPLICE COUPLING

NEAR INTERMEDIATE ANCHOR

21.7.221.6.2

EXISTING SECTION

REPAIR SECTION

NOTES:

1. SEE DETAILS 21.6 AND 21.7 FOR REMAINING INFORMATION.

2. MAINTAIN ORIGINAL TENDON PROFILE.

GRID

REPAIR CONCRETE

SEE W.I. 3.0 SERIES

5" -7

GRID

1'-6" RUST FREE TENDON (TYP.)

BROKEN OR PREVIOUSLY

CUT P/T TENDON

P/T TENDON

FLOOR DELAMINATION

EXIST. SLAB

EXIST. BEAM

NEW P/T TENDON AND (2)

COUPLINGS. (NOTE 2)

EXIST. TENDON

REMOVE AND REPLACE

CONC. IN SECTION

SHOWN SHADED.

REPLACE CONC. FULL

DEPTH AS REQ'D.

EXIST. TENDON

REMOVAL LIMITS

(TYP.)

EXIST. BEAM

TENDON SPLICE COUPLING (DOUBLE)

21.8

EXISTING SECTION

REPAIRED SECTION

NOTES:

1. IF TWO OR MORE FAILED TENDONS PER RUN, STAGGER THE COUPLERS AS REQ'D. FOR STRESSING

OPERATIONS. STRESS TENDON(S) PER W.I. 21.3 OR 21.6 AS DIREDTED BY ENGINEER.

2. NEW TENDON LENGTH BEYOND 10'-0" SHALL BE PAID FOR UNDER W.I. 21.9.

1" C

L.

TY

P.

REPAIR CONCRETE.

SEE W.I. 3.0 SERIES.

5" -7

1'-6" RUST FREE TENDON (TYP)

FLOOR SLAB

BROKEN TENDON

SLAB MID-SPAN

CEILING DELAMINATION

REMOVAL LIMITS (TYP)

EXISTING TENDON

SLAB MID-SPANREMOVE AND REPLACE

CONCRETE IN SECTION SHOWN

SHADED. REPLACE CONCRETE

FULL DEPTH AS REQUIRED.

NEW P/T TENDON AND (2)

COUPLINGS (NOTE 2).EXISTING TENDON

TENDON SPLICE COUPLING (DOUBLE)

21.8.1

EXISTING SECTION

REPAIRED SECTION

NOTES:

1. IF TWO OR MORE FAILED TENDONS PER RUN, STAGGER THE COUPLERS AS REQUIRED FOR STRESSING

OPERATIONS. STRESS TENDON(S) PER WORK ITEM 21.3 OR 21.6 AS DIRECTED BY ENGINEER.

2. NEW TENDON LENGTH BEYOND 10'-0" SHALL BE PAID FOR UNDER WORK ITEM 21.9.

3/ 4"

C

LR

M

IN

(T

YP

REPAIR CONCRETE.

SEE W.I. 3.0 SERIES.

R-504

REPAIR

DETAILS

SHEET TITLE:

D

ES

C R

IP

TI

O N

IS

SU

E:

M

AR

K D

AT

E

PROJECT NO:

DRAWN BY:

CHECKED BY:

20-002368.00

Copyright 2023. All rights reserved. No part of this document may be reproduced in any form or by any means without permission from Walker Consultants

J:

\M

IC

H

IG

AN

\2 0-

-0

0-

PO

R T_

H U

R O

N _M

O C

_P S_

_R

PR

S\ D

R

AW

IN

G

S\

R

-5

S

ER

IE

S.

D W

G

/1 4/

2:

:0

PM

W

YL

IE

, K

EV

IN

C O

N S

U L

T A

N T

S W A L K E R

Av is

D riv e Su ite

An n

Ar bo r, M

I 4

4.

3.

P h w w w

.w al ke rc on su lta nt s.

co m

M

IC

H

IG

AN

PA

R

KI

N

G S

TR

U

C

TU

R E

R

EP

AI

R

S

C

IT

Y O

F

PO

R T

H U

R O

N

PO

RT

H

UR

ON

ECC

EK

BI

D

D

IN

G A

N D

C O

N

ST

R U

C

TI

O N

/2

3/

TUCKPOINTING

76.1A

3/ 8"

-1 /2

" T

YP

JO

IN

T W

ID

TH

(V

IF

EXISTING MORTAR

PLACE TUCKPOINTING

MORTAR IN 3 EVEN LIFTS

EXISTING MARBLE

FACADE MATERIAL

TOOL CONCAVE

JOINT

REMOVE ALL UNSOUND OR DETERIORATED MORTAR IN

HATCHED AREA AND PLACE NEW MORTAR

NEW

MORTAR

2" TYP

NOTES:

1. REMOVE LOOSE MATERIAL FROM JOINT.

2. FILL ANY VOIDS IN JOINT BEYOND POINTING WORK DEPTH.

3. GRIND FACADE SURFACES CLEAN OF EXISTING MORTAR. DO NOT DAMAGE ADJACENT MASONRY.

4. TOOL MORTAR JOINT CONCAVE.

5. MORTAR COLOR SHALL MATCH EXISTING COLOR OF ADJACENT MORTAR. PROVIDE SAMPLE FOR

OWNER'S APPROVAL PRIOR TO START OF WORK.

6. THIS DETAIL APPLIES TO BOTH HORIZONTAL AND VERTICAL MORTAR JOINTS AS REQUIRED.

4" (VIF)VARIES

CAVITYCONCRETE OR

BLOCK BACK-UP

WALL

REPLACE LINTEL (DOOR)

76.4B

REPLACE SHELF ANGLE (GARAGE DOOR)

76.4A

MASONRY - REMOVE/RESET FLUTED CMU

76.2

W.I. 76.2: REMOVE /

RESET FLUTED CMU

AS NEEDED TO

REPLACE SHELF

ANGLE AND LINTEL.

W.I. 76.4A: REPLACE

SHELF ANGLE ALONG

FULL WIDTH OF

GARAGE DOOR. SEE

DETAIL 76.4A.1 FOR

FURTHER

INFORMATION.

W.I. 76.4B: REPLACE

LINTEL ABOVE DOOR.

SEE DETAIL 76.4B.1

FOR FURTHER

INFORMATION.

NEW LINTEL

TO BEAR

MINIMUM 10"

ONTO

MASONRY.

GRIND/FILL

MORTAR AS

NECESSARY.

REMOVE/RESET

FACADE STONES

OR TEMPORARILY

SUPPORT IN PLACE

TO FACILITATE

SHELF ANGLE AND

LINTEL

REPLACEMENT

(INCIDENTAL TO

W.I.'S 76.4A & 76.4B).

AI

R

C

AV

IT

Y

MASONRY - REMOVE/RESET FLUTED CMU

76.2.1

P/T

CONCRETE

BEAM

NOTE 2

NOTES:

1. ASSUMED EXISTING CONSTRUCTION SHOWN (SHELF ANGLE BOLTED TO CONCRETE BEAM

BEHIND). REMOVE 1 OR 2 FLUTED CMU AND ALLOW ENGINEER TO OBSERVE CAVITY TO CONFIRM

EXISTING CONSTRUCTION PRIOR TO PROCEEDING WITH WORK.

2. REMOVE EXISTING ANCHORS (LOCATIONS/SPACING UNKNOWN). REPLACE WITH 1/2" DIA S.S. HILTI

"HAS-R" THREADED RODS EPOXY-ANCHORED WITH HILTI HIT-HY 200 AT 18" OC. LOCATE

EMBEDDED REINFORCEMENT AND PT TENDONS WITH GPR PRIOR TO DRILLING.

SELF ADHERED

FLASHING W/

END DAMS

CELL VENT

WEEPS @

24" OC

SS DRIP

EDGE - SET

IN BED OF

SEALANT

SEALANT

TERM BAR

FASTENED

@ 12" OC

REPLACE SHELF ANGLE (GARAGE DOOR)

76.4A.1

±2 4"

4"

METAL GARAGE DOOR COVER

REPLACE EXISTING SHELF ANGLE (3/8"X3.5"X3.5"). NOTE 1.

EXISTING FACADE

STONES.

REMOVE/RESET

OR TEMPORARILY

SUPPORT IN

PLACE TO

FACILITATE SHELF

ANGLE

REPLACEMENT

(INCIDENTAL TO

W.I. 76.4A).

3 COURSES OF

EXISTING

FLUTED CMU.

REMOVE /

RESET PER W.I.

76.2. NOTE 1.

AI

R

C

AV

IT

Y

MASONRY - REMOVE / RESET FLUTED CMU

76.2.2

P/T

CONCRETE

BEAM

NOTES:

1. ASSUMED EXISTING CONSTRUCTION SHOWN (LOOSE-LAID LINTEL BEARING ON MASONRY AT

DOOR OPENING). REMOVE 1 OR 2 FLUTED CMU AND ALLOW ENGINEER TO OBSERVE CAVITY

TO CONFIRM EXISTING CONSTRUCTION PRIOR TO PROCEEDING WITH WORK.

SELF ADHERED

FLASHING W/

END DAMS

CELL VENT

WEEPS @

24" OC

SS DRIP

EDGE - SET

IN BED OF

SEALANT

EXISTING FACADE

STONES.

REMOVE/RESET

OR TEMPORARILY

SUPPORT IN

PLACE TO

FACILITATE LINTEL

REPLACEMENT

(INCIDENTAL TO

W.I. 76.4A).

SEALANT

TERM BAR

FASTENED

@ 12" OC

REPLACE LINTEL (DOOR)

76.4B.1

±2 4"

4"

REPLACE EXISTING LINTEL

(3/8"X3.5"X3.5"). NOTE 1.

3 COURSES OF

EXISTING

FLUTED CMU.

REMOVE /

RESET PER W.I.

76.2. NOTE 1.

MIN 1/4" GAP

SEALANT &

BACKER ROD

EXIST MASONRY

TO REMAIN

1/4" ETHAFOAM

SHEET

REMOVE PARKING METER POSTS

50.2

NOTES:

1. PRIOR TO PERFORMING WORK, CONTRACTOR SHALL CONFIRM LOCATIONS WITH ENGINEER IN FIELD.

2. REMOVAL INCLUDES THE POST, ACHORING FLANGE, AND ALL ANCHORING HARDWARE. FLANGE IS

TYPICALLY SECURED TO THE CONCRETE CURB OR OVERLAY BY 4 ANCHORS (VIF).

3. PAYMENT SHALL BE PER EACH POST REMOVED. ANCHORING FLANGE AND HARDWARE ARE

INCIDENTAL.

4. CONTRACTOR SHALL COMPLETELY FILL ANCHOR HOLES WITH A POLYURETHANE SEALANT. REFER

TO SPECIFICATION SECTION 79233 FOR LIST OF ACCEPTIBLE MATERIALS. SEALANT SHALL BE

INSTALLED FLUSH WITH ADJACENT SURFACES.

REMOVE EXISTING

PARKING METER

POSTS (TYP)

NOTES:

1. SIGN TO MEET STATE OF MICHIGAN

REQUIREMENTS.

2. SEE DETAIL 50.3 FOR SIGN MOUNTING HEIGHT

1'-0"

1' -6

6"R7-8b

1"

PARKING

ONLY

MINIMUM

FINE $250

1" 6"

VAN

ACCESSIBLE

3/8" BORDER,

COLOR WHITE

TEXT & SYMBOL,

COLOR WHITE

BACKGROUND,

COLOR BLUE

1/

8"

3/ 8"

1/

2"

BACKGROUND,

COLOR BLUE

3/8" BORDER,

COLOR WHITE

PROVIDE / INSTALL ADA PARKING SIGN / POST

50.3.1

(SIGNS)

PROVIDE / INSTALL

ADA PARKING SIGN / POST

50.3

TOP OF CONCRETE

CURB OR OVERLAY

(NOTE 1)

SURFACE MOUNT POST

ANCHORS BY TAPCO

(034-00142) ATTACHED

W/ (4) 5/16" x 5"

STAINLESS STEEL EXP

ANCHORS.

2" x 2" SQUARE POST W/

7/16" DIA HOLES @ 1"

OC. ATTACH TO POST

ANCHORS W/ (2) 3/8"Ø

STAINLESS STEEL

BOLTS/NUTS.

SIGN PANEL (SEE

DETAIL 50.3.1). FASTEN

TO POST WITH TAMPER

PROOF STAINLESS

STEEL BOLTS/NUTS.

ALUMINUM POST CAP

PARKING

ONLY

MINIMUM

FINE $250

VAN

ACCESSIBLE

5' -0

(POST AND ANCHORING)

NOTE:

1. CONTRACTOR SHALL

TAKE ALL PRECAUTIONS

NECESSARY TO AVOID

DAMAGING THE

CONCRETE CURB OR

OVERLAY REINFORCING

STEEL (NOT SHOWN).

R-505

REPAIR

DETAILS

SHEET TITLE:

D

ES

C R

IP

TI

O N

IS

SU

E:

M

AR

K D

AT

E

PROJECT NO:

DRAWN BY:

CHECKED BY:

20-002368.00

Copyright 2023. All rights reserved. No part of this document may be reproduced in any form or by any means without permission from Walker Consultants

J:

\M

IC

H

IG

AN

\2 0-

-0

0-

PO

R T_

H U

R O

N _M

O C

_P S_

_R

PR

S\ D

R

AW

IN

G

S\

R

-5

S

ER

IE

S.

D W

G

/1 4/

2:

:0

PM

W

YL

IE

, K

EV

IN

C O

N S

U L

T A

N T

S W A L K E R

Av is

D riv e Su ite

An n

Ar bo r, M

I 4

4.

3.

P h w w w

.w al ke rc on su lta nt s.

co m

M

IC

H

IG

AN

PA

R

KI

N

G S

TR

U

C

TU

R E

R

EP

AI

R

S

C

IT

Y O

F

PO

R T

H U

R O

N

PO

RT

H

UR

ON

ECC

EK

BI

D

D

IN

G A

N D

C O

N

ST

R U

C

TI

O N

/2

3/

2368R-000-COVER
COVER
2368R-001-Layout1
Layout1
2368R-101-Layout1
Layout1
2368R-102 Layout1 (1)
2368R-501
R-501
2368R-502
R-502
2368R-503
R-503
2368R-504
R-504
2368R-505
R-505

File details come from the government source that posted it. Updated .