2023-11-15 - Design Drawings - White Stone WWTP Phase 2.pdf
PDF 43 MB Posted
- Attached to
- Town of White Stone - Sewage Collection and Treatment System - Phase 2 - Advertisement for Bids
- Solicitation number
- 87948
- Issued by
- Lee County, Virginia
About this file
Unable to access or view the contents of the file "2023-11-15 - Design Drawings - White Stone WWTP Phase 2.pdf". While the filename suggests these are design drawings for Phase 2 of the White Stone Wastewater Treatment Plant, without access to the actual document contents, I cannot provide a detailed summary of the specifications, requirements, or technical details contained within.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TO
W
N O
F W
H
IT
E S
TO
N
E S
E W
A G
E C
O
LL
E C
TI
O
N
T R
E A
TM
E
N T
- P H
A S
E
LA
N
C A
S T
E R
C O
U N
T Y
V
IR
G
IN
IA
B ow m an
C on su lti ng G ro up
, L td
P ho ne
7)
-1
F ax
7)
-4 w w w .b ow m an co ns ul tin g.
co m
B ow m an
C on su lti ng G ro up
, L td
M cL aw s C irc le
S ui te
W ill ia m sb ur g, V irg in ia
PROJECTNO
TCW/DWD DWD RJK
OCT. 8, 2021
8271-01-005-XXX
8271-01-005
OWNER
TOWN OF WHITE STONE
C/O PATRICK FRERE, TOWN MANAGER
433 RAPPAHANNOCK DR.
WHITE STONE, VA 22578
PH: (804) 436-4935
TOWN OF WHITE STONE SEWAGE
COLLECTION & TREATMENT SYSTEM - PHASE 2
LANCASTER COUNTY VIRGINIA
SITE LOCATION
MAPPING SOURCE: USGS "IRVINGTON, VA", "FLEETS BAY, VA", "WILTON, VA" "DELTAVILLE, VA" QUAD SHEETS, DATED 2013
PHASE 2
PROJECT
LIMITS
GENERAL NOTES:
1. THE NEW COLLECTION SYSTEM INCLUDES THE INSTALLATION OF 160 GRINDER PUMPS AND 17,500 LINEAR FEET OF NEW SEWER FORCE MAIN RANGING IN SIZE FROM 2"-4". THE PROJECT ALSO INCLUDES THE INSTALLATION OF THE SECOND PHASE OF THE TOWN'S EXISTING WASTEWATER TREATMENT PLANT, A 40,000 MOVING BED BIOLOGICAL REACTOR HOUSED IN PRECAST CONCRETE TANKS, AND A 40,000 GPD
DRIP IRRIGATION DISPOSAL SYSTEM.
1.1. THE LINEAR PORTION OF THE PROJECT CAN BE FOUND ON SHEETS C-3 TO C-19. THE 17,500 LINEAR FEET WILL HAVE APPROXIMATELY A 10-FOOT TRENCH, RESULTING IN APPROXIMATELY 175,000
SQUARE FEET (4.02 ACRES) OF LINEAR PROJECT AREA.
1.2. THE STORMWATER MANAGEMENT PLAN INCLUDES THE DRIP DISPOSAL SYSTEM, ON SHEETS D-1 TO D-6. THE APPROXIMATE ACREAGE OF THE DRAINFIELDS IS NOTED IN THE CALCULATION TABLES ON
SHEET SWM-2 AS 10.71 ACRES.
2. ALL CONSTRUCTION OF THIS SYSTEM SHALL BE IN ACCORDANCE WITH THE VIRGINIA DEPARTMENT OF
ENVIRONMENTAL QUALITY SEWAGE COLLECTION AND TREATMENT REGULATIONS, THE VIRGINIA
SEWERAGE HANDLING AND DISPOSAL REGULATIONS, THE TECHNICAL SPECIFICATIONS, AND THE
MANUFACTURER'S RECOMMENDATIONS.
3. CONTRACTOR SHALL CONTACT THE ENGINEER BEFORE STARTING CONSTRUCTION FOR A
PRE-CONSTRUCTION CONFERENCE.
4. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND CONSTRUCTION OF ANY BUILDING AND EQUIPMENT
FOUNDATIONS.
5. ALL TANKS SHALL BE INSTALLED LEVEL (±1/2").
6. ANY DEVIATION FROM THIS DESIGN MUST BE APPROVED PRIOR TO INSTALLATION BY THE ENGINEER.
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING, PROTECTING, AND RESOLVING ANY CONFLICTS WITH EXISTING UTILITIES AND SHALL REPAIR, AT HIS OWN EXPENSE, ALL UTILITIES TO BE
RELOCATED OR DAMAGED BY THE CONTRACTOR.
8. BEFORE DIGGING, CALL "MISS UTILITIES" OF VIRGINIA, 1-800-552-7001.
9. THE CONTRACTOR SHALL OBTAIN, AT HIS OWN EXPENSE, ANY LOCAL PERMITS, BONDS, OR INSPECTIONS, IF REQUIRED BY ANY GOVERNMENT AGENCY.
10. THE CONTRACTOR SHALL COMPLY WITH EROSION AND SEDIMENT CONTROL STANDARDS OUTLINED IN THE LATEST EDITION OF THE VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK (VESCH). THESE
ARE MINIMUM REQUIREMENTS. FIELD CONDITIONS MAY REQUIRE ADDITIONAL CONTROLS.
11. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE LAWS, ORDINANCES, RULES, REGULATIONS AND ORDERS OF ANY PUBLIC BODY HAVING JURISDICTION. THE CONTRACTOR SHALL ERECT AND
MAINTAIN, AS REQUIRED BY THE CONDITIONS AND PROGRESS OF THE WORK, ALL NECESSARY
SAFEGUARDS FOR SAFETY AND PROTECTION.
12. THE CONTRACTOR IS RESPONSIBLE FOR SECURING A COPY OF THE LATEST EDITION OF THE VIRGINIA WORK AREA PROTECTION MANUAL. STANDARDS AND GUIDELINES FOR TEMPORARY TRAFFIC CONTROL BY THE VIRGINIA DEPARTMENT OF TRANSPORTATION. THESE STANDARDS AND GUIDELINES SHALL BE KEPT ON THE PROJECT SITE AT ALL TIMES DURING CONSTRUCTION. THE APPLICABLE TRAFFIC
CONTROLS SHALL BE FOLLOWED DEPENDING ON SPECIFIC SITE CONDITIONS.
13. WHEN WORKING WITHIN THE RIGHT-OF-WAY THE CONTRACTOR SHALL COMPLY WITH THE LATEST
EDITION OF VDOT'S ROAD AND BRIDGE STANDARDS.
14. TO MITIGATE IMPACT TO PRIVATE PROPERTY, EXISTING UTILITIES AND STRUCTURES AND POWER POLES, THE BULK OF THE HDPE PIPING SHALL BE CONSTRUCTED BY THE CONTRACTOR USING DIRECTIONAL DRILLING METHODS. PORTIONS OF THE PIPING, HOWEVER, WILL NEED TO BE OPEN CUT TO FACILITATE MAKING CONNECTIONS AND ACCOMMODATING CHANGES TO LINE AND GRADE AS NEEDED TO CONSTRUCT THE PROJECT.
ANY AREAS WHERE THE CONTRACTOR PROPOSES TO INSTALL TRENCHES IN CLOSE PROXIMITY TO POWER POLES, THE CONTRACTOR SHALL COORDINATE WITH THE POWER COMPANY IN PROVIDING TEMPORARY SUPPORT OF THE POLE AND/OR TEMPORARY DEENERGIZING OF THE POWER SYSTEM DURING THE TRENCHING OPERATION. THE CONTRACTOR IS RESPONSIBLE FOR FULLY RESTORING ALL AREAS IMPACTED BY CONSTRUCTION.
SHEET INDEX
GENERAL
G-1 COVER SHEET
G-2 OVERALL LAYOUT & INDEX OF PLAN & PROFILE SHEETS
CIVIL
C-1 EROSION AND SEDIMENT CONTROL NOTES
C-2 EROSION AND SEDIMENT CONTROL DETAILS
C-3 RAPPAHANNOCK DR. & MARY BALL RD.
C-4 RAPPAHANNOCK DR. CONNECTION TO PHASE 1
C-5 CHERRY POINT DR. - STA. 10+00 TO 24+00
C-6 CHERRY POINT DR. - STA. 24+00 TO 35+50
C-7 SHELTON DR.
C-8 BOLES AVE. - STA. 10+00 TO 18+00
C-9 BOLES AVE. - STA. 18+00 TO 27+00
C-10 SHADY LA. - STA. 10+00 TO 19+00
C-11 SHADY LA. - STA. 19+00 TO 28+60
C-12 DAWSON AVE.
C-13 BEACH RD. - STA. 10+00 TO 24+00
C-14 BEACH RD. - STA. 24+00 TO 38+00
C-15 BEACH RD. - STA. 38+00 TO 52+00
C-16 BEACH RD. & OLD MAIL RD. - STA. 52+00 TO 63+50
C-17 BRUCE AVE.
C-18 PINE DR.
C-19 PLEASANT BANKS LA.
C-20 GRINDER PUMP LISTING & SHEET INDEX
C-21 PHASE 2 GRINDER PUMPS CONNECTING TO PHASE 1 FORCEMAIN
C-22 GRINDER PUMPS & MULTI-HOUSE COLLECTORS PLAN - 1
C-23 GRINDER PUMPS & MULTI-HOUSE COLLECTORS PLAN - 2
C-24 GRINDER PUMPS & MULTI-HOUSE COLLECTORS PLAN - 3
C-25 GRINDER PUMPS & MULTI-HOUSE COLLECTORS PLAN - 4
C-26 GRINDER PUMPS & MULTI-HOUSE COLLECTORS PLAN - 5
C-27 GRINDER PUMPS & MULTI-HOUSE COLLECTORS PLAN - 6
C-28 GRINDER PUMPS & MULTI-HOUSE COLLECTORS PLAN - 7
C-29 GRINDER PUMPS & MULTI-HOUSE COLLECTORS PLAN - 8
C-30 GRINDER PUMPS & MULTI-HOUSE COLLECTORS PLAN - 9
C-31 GRINDER PUMPS & MULTI-HOUSE COLLECTORS PLAN - 10
C-32 GRINDER PUMPS & MULTI-HOUSE COLLECTORS PLAN - 11
C-33 COLLECTION SYSTEM DETAILS - 1
C-34 COLLECTION SYSTEM DETAILS - 2
C-35 COLLECTION SYSTEM DETAILS - 3
C-36 TRAFFIC CONTROL DETAILS
DRIP DISPOSAL
D-1 OVERALL DRAIN FIELD PLAN
D-2 DETAIL - DRAIN FIELDS 1 & 2
D-3 DETAIL - DRAIN FIELDS 3 & 4
D-4 DETAIL - DRAIN FIELDS 5 & 6
D-5 DRIP IRRIGATION DETAILS - 1
D-6 DRIP IRRIGATION DETAILS - 2
MECHANICAL
M-1 PROCESS FLOW DIAGRAM
M-2 SITE PIPING PLAN
M-3 CONTROL BUILDING PLAN
M-4 WWTP PARTIAL PLAN VIEW - 1
M-5 WWTP PARTIAL PLAN VIEW - 2
M-6 WWTP PARTIAL PROFILE - 1
M-7 WWTP PARTIAL PROFILE - 2
M-8 WWTP PARTIAL PROFILE - 3
M-9 TREATMENT PLANT DETAILS - 1
M-10 TREATMENT PLANT DETAILS - 2
STORM WATER MANAGEMENT
SWM-1 STORMWATER QUANTITY NARRATIVE
SWM-2 VRRM EXHIBIT
ELECTRICAL
E-1 ELECTRICAL NOTES, ABBREVIATIONS & SYMBOL LEGEND
E-2 PARTIAL ONE-LINE DIAGRAM
E-3 CONTROL BUILDING ELECTRICAL PLAN
E-4 WWTP ELECTRICAL PLAN - PHASE 1 (EXISTING)
E-5 WWTP ELECTRICAL PLAN - PHASE 2
E-6 DRIP IRRIGATION CONTROL PANEL
E-7 PHASE 2 WWTP CONTROL PANEL
E-8 ELEC. CALCS, GROUNDING PLAN, JUNC. BOX DETAIL
E-9 ELECTRICAL DETAILS
E-10 ELECTRICAL PANEL SCHEDULES
E-11 DRAINFIELD ELECTRICAL SITE PLAN
E-12 WWTP ELECTRICAL SITE PLAN
SURVEY NOTES:
1. HORIZONTAL DATUM IS NAD 83 AND THE VERTICAL DATUM IS NAVD 88 BASED ON A GPS SURVEY BY
BOWMAN TIED TO NGS AND/OR COUNTY GPS MONUMENTS.
2. COMPILED BOUNDARY AND RIGHT OF WAY INFORMATION AS SHOWN HEREON IS COMPILED FROM VDOT R/W PLANS, DEEDS AND PLATS RECORDED IN THE LAND RECORDS OF LANCASTER COUNTY, VIRGINIA
AND MADE TO BEST FIT FOUND MONUMENTATION.
3. THIS SURVEY DOES NOT REPRESENT A BOUNDARY SURVEY OF ANY PARCEL, NOR HAVE ANY CORNERS
BEEN SET.
4. THE SURVEYED PROPERTY AS SHOWN HEREON IS SUBJECT TO ALL COVENANTS AND RESTRICTIONS OF RECORD. BOWMAN WAS NOT PROVIDED A COMMITMENTS FOR TITLE INSURANCE THEREFORE NOT ALL
EASEMENTS MAY BE SHOWN AND PROPERTIES ARE SUBJECT TO ALL ENCUMBRANCES OF RECORD.
5. BOWMAN PERFORMED IN FIELD LOCATIONS IN JULY, 2021.
6. TOPOGRAPHY SHOWN HEREON IS AERIAL PHOTOGRAMMETRY PROVIDED BY TUCK MAPPING ON 3/14/2020 & 9/16/2021 . MINIMUM SUPPLEMENTAL SURVEY PERFORMED BY BOWMAN CONSULTING. CONTOURS MAY
NOT HAVE BEEN TRIMMED THROUGH DWELLINGS OUTSIDE PROJECT SCOPE AREA.
7. NO UNDERGROUND UTILITIES WERE MARKED OR LOCATED BY BOWMAN AS PART OF THIS DELIVERABLE.
8. SEPTIC TANK LOCATIONS WERE FLAGGED IN THE FIELD BY THE COUNTY INTERMITTENTLY. ALL SEPTIC TANKS MAY NOT BE SHOWN OR MARKED. CONTRACTOR SHALL FIELD LOCATE EACH SEPTIC TANK IN THE
PROJECT AREA.
WASTE WATER
TREATMENT PLANT &
DRAINFIELDS SITE
282 MOSQUITO POINT
ROAD, WHITE STONE
VIRGINIA 22578
P:\8271 - White Stone\8271-01-005 (ENG) - WW Phase 2 Design Phase\Engineering\Engineering Plans\8271-01-005-COV.dwg
CO
VE
R
SH
EE
T gjq26738 PRO-SWM Approval Stamp gjq26738 Elizabeth Southers gjq26738 Text Box 07/31/2023
N O
F W
H
IT
E S
TO
N
E S
E W
A G
E C
O
LL
E C
TI
O
N
T R
E A
TM
E
N T
- P H
A S
E
LA
N
C A
S T
E R
C O
U N
T Y
V
IR
G
IN
IA
B ow m an
C on su lti ng G ro up
, L td
P ho ne
7)
-1
F ax
7)
-4 w w w .b ow m an co ns ul tin g.
co m
B ow m an
C on su lti ng G ro up
, L td
M cL aw s C irc le
S ui te
W ill ia m sb ur g, V irg in ia
PROJECTNO
TCW/DWD DWD RJK
OCT. 8, 2021
8271-01-005-XXX
8271-01-005
PHASE 2 WWTP
SHEET C-3
SHEET C
-5
SHEET C
-6
SHEET C-7
SHEET C-8
SHEET C-9
SHEET C-10
RAPPAHANNOCK DR. - S
.R. 3
BOLES AVE. -
S.R. 1
CHERRY P
OIN
T
DR. -
S .R
. 6
SHADY LN. - S.R. 638
SHADY LN. - S.R. 652
DAW
SO
N A
VE
S
.R . 1
BE
AC
H R D. -
S .R
. 6
OLD MAIL RD.
SHELTON DR.
BRUCE AVE. - S.R. 1201
PIN
E D
R. - S
.R . 1
PLEASANT BANKS LA.
JAMES WHARF RD. - S.R. 637
SH
EE
T C-1
SH
EE
T C-
SH
EE
T C-1
SH
EE
T C
-1
SHEET C-16
SHEET
C-1
SHEET C-18
SHEET C-19
SHEET C-4
CHESAPEAKE DR. - S.R. 200
MARY BALL RD. - S
.R. 3
SHEET C-11
BR
UCE
AV
E.
S.
R. 1
P:\8271 - White Stone\8271-01-005 (ENG) - WW Phase 2 Design Phase\Engineering\Engineering Plans\8271-01-005-PNP.dwg
O
VE
RA
LL
L
AY
O
UT
IN
DE
X
O F
PL
AN
P
RO
FI
LE
S
HE
ET
S
GRAPHIC SCALE
( IN FEET )
1 inch = ft.250
NOTES:
1. SHEETS C-5 THROUGH C-19 ARE PLAN AND PROFILE SHEETS FOR THE MAIN
SYSTEM FORCEMAINS. REFER TO SHEETS C-20 THROUGH C-32 FOR GRINDER
PUMPS, LATERALS AND MULTI-HOUSE COLLECTORS (MHC).
SECONDARY CONNECTION POINT
TO EXISTING PHASE 1 FORCE MAIN
PRIMARY CONNECTION POINT TO
EXISTING PHASE 1 FORCE MAIN
SANITARY MANHOLE
WATER MANHOLE
SIAMESE CONNECTION
UTILITY POLE
CLEAN OUT
WATER VALVE
SIGN
PK NAIL FOUND
UTILITY PEDESTAL
MAILBOX
GUY WIRE
FENCE LINE
IRON ROD FOUND
DRILL HOLD FOUND
IRRIGATION CONTROL VAVLE
MANHOLE
LIGHT POLE
GROUND LIGHT
FIRE HYDRANT
POWER POLE
UTILITY VAULT
ELECTRIC METER
STORM DRAIN INLET
CONCRETE SIDEWALK
ELECTRIC TRANSFORMER
WATER METER
POINT OF ENTRY
ELECTRIC OUTLET
FIBER OPTIC WITNESS POST
TRAFFIC SIGNAL POLE WITH MAST ARM
COMMUNICATION VAULT
AIR RELEASE VALVE
"#" INCH WATERLINE
SYMBOL & ABBREVIATION LEGEND
TEMPORARY EASEMENT
PERMANENT EASEMENT
IRON PIPE FOUND
POWER POLE
RIGHT OF WAY
WELL
PHASE 2 DRAIN FIELD
PHASE 2 RESERVE
DRAIN FIELD AREA
VRRM GROUND COVER LEGEND
FOREST/OPEN SPACE - 13.85 Ac.
MANAGED TURF - 10.71 Ac.
WWTP SITE - 19.48 Ac.
LINEAR EXEMPTION TO THE VSMP - 4.02 Ac.
N O
F W
H
IT
E S
TO
N
E S
E W
A G
E C
O
LL
E C
TI
O
N
T R
E A
TM
E
N T
- P H
A S
E
LA
N
C A
S T
E R
C O
U N
T Y
V
IR
G
IN
IA
B ow m an
C on su lti ng G ro up
, L td
P ho ne
7)
-1
F ax
7)
-4 w w w .b ow m an co ns ul tin g.
co m
B ow m an
C on su lti ng G ro up
, L td
M cL aw s C irc le
S ui te
W ill ia m sb ur g, V irg in ia
PROJECTNO
TCW/DWD DWD RJK
OCT. 8, 2021
8271-01-005-XXX
8271-01-005
GENERAL EROSION AND SEDIMENT CONTROL
NOTES
EROSION AND SEDIMENT CONTROL NARRATIVE MINIMUM STANDARDS OF THE VIRGINIA
EROSION AND SEDIMENT CONTROL REGULATIONS
MS-1
MS-2
MS-3
MS-4
MS-5
MS-6
MS-7
MS-8
MS-9
MS-10
MS-11
MS-12
MS-13
MS-14
MS-15
MS-16
MS-17
MS-18
X
N/A
X
X
X
X
X
X
X
X
X
X
N/A
N/A
N/A
N/A
N/A
N/A
COMPLIES
X
P:\8271 - White Stone\8271-01-005 (ENG) - WW Phase 2 Design Phase\Engineering\Engineering Plans\8271-01-005-ENS.dwg
ER
O
SI
O
N
AN
D
SE
DI
M
EN
T
CO
NT
RO
L
NO
TE
S
MS-19
POLLUTION PREVENTION NOTES:
N O
F W
H
IT
E S
TO
N
E S
E W
A G
E C
O
LL
E C
TI
O
N
T R
E A
TM
E
N T
- P H
A S
E
LA
N
C A
S T
E R
C O
U N
T Y
V
IR
G
IN
IA
B ow m an
C on su lti ng G ro up
, L td
P ho ne
7)
-1
F ax
7)
-4 w w w .b ow m an co ns ul tin g.
co m
B ow m an
C on su lti ng G ro up
, L td
M cL aw s C irc le
S ui te
W ill ia m sb ur g, V irg in ia
PROJECTNO
TCW/DWD DWD RJK
OCT. 8, 2021
8271-01-005-XXX
8271-01-005
TABLE 3.32-D
SITE SPECIFIC SEEDING MIXTURES FOR COASTAL PLAIN AREA
SOILS MAP
P:\8271 - White Stone\8271-01-005 (ENG) - WW Phase 2 Design Phase\Engineering\Engineering Plans\8271-01-005-ENS.dwg
ER
O
SI
O
N
AN
D
SE
DI
M
EN
T
CO
NT
RO
L
DE
TA
IL
S
STORMWATER MANAGEMENT NOTES:
EX. GROUND
EX. 12" RCP CULVERT
RE
MO
VE
E
X.
T
ER
MI
NA
L
FL
US
HI
NG
C
ON
N.
CO
NN
EC
T
TO
E X.
6" F
OR
CE
M
AI
N W
IT
H
6" x4
" R
ED
UC
ER
4" G
AT
E
VA
LV
E
ST
A=
+5
0.0
4"
° B
EN
D
ST
A=
+6 0.0
4"
° B
EN
D
ST
A=
+6
4.3
TE
RM
IN
AL
F
LU
SH
IN
G
CO
NN
EN
D
4" F
OR
CE
M
AI
N
ST
A=
+4
0.0
88 L.F. 8" ENCASEMENT PIPE
UNDER JAMES WHARF RD.
PER VDOT EP-1 DETAIL
ON SHEET C-34
3'
MI
N.
4" HDPE FORCE MAIN
TEST PIT
REQUIRED
TEST PIT
REQUIRED
TEST PIT
REQUIRED
POSSIBLE WATER
SERVICES
3.6 "±18
" M
IN
" M
IN
" M
IN
TEST PIT, SEE NOTE 9
TEST PIT, SEE NOTE 9
TEST PIT, SEE NOTE 9
STA 31+50.00
REMOVE EX. TERMINAL
FLUSHING CONN.
CONNECT TO EX. 6" FORCE MAIN
WITH 6"x4" REDUCER
4" GATE VALVE
N=3,765,309.88 E=12,092,063.52
STA 31+60.00
4" 45° BEND
N=3,765,304.32 E=12,092,055.21
STA 31+64.32
4" 45° BEND
N=3,765,300.08 E=12,092,054.36
STA 38+40.00
TERMINAL FLUSHING CONN.
END 4" FORCE MAIN
N=3,764,924.70
E=12,091,492.56
88 L.F. 8" ENCASEMENT PIPE
PER VDOT EP-1 DETAIL ON SHEET C-34POSSIBLE WATER
SERVICES, TEST
PITS REQUIRED
STA 38+16
SERVICE TEE
STA 37+33
SERVICE TEE
STA 36+16
SERVICE TEE
STA 37+56
SERVICE TEE
PROPOSED TEMPORARY EASEMENT
TO
W
N O
F W
H
IT
E S
TO
N
E S
E W
A G
E C
O
LL
E C
TI
O
N
T R
E A
TM
E
N T
- P H
A S
E
LA
N
C A
S T
E R
C O
U N
T Y
V
IR
G
IN
IA
B ow m an
C on su lti ng G ro up
, L td
P ho ne
7)
-1
F ax
7)
-4 w w w .b ow m an co ns ul tin g.
co m
B ow m an
C on su lti ng G ro up
, L td
M cL aw s C irc le
S ui te
W ill ia m sb ur g, V irg in ia
PROJECTNO
TCW/DWD DWD RJK
OCT. 8, 2021
8271-01-005-XXX
8271-01-005
RAPPAHANNOCK DR. - S.R. 3
JAMES WHARF RD. - S.R. 637
MARY BALL RD. - S.R. 3
31+0032+0033+0034+0035+0036+0038+00 37+00
PROFILE - RAPPAHANNOCK DR. & MARY BALL RD. NOTES:
1. SHEETS C-5 THROUGH C-19 REFER TO ALIGNMENT FOR THE MAIN SYSTEM
FORCEMAINS. REFER TO SHEETS C-20 THROUGH C-32 FOR GRINDER PUMPS,
LATERALS AND MULTI-HOUSE COLLECTORS (MHC).
2. SERVICE TEES SHOWN IN PROFILE FOR MHC'S AND FORCEMAIN. TEES FOR
SERVICE LATERALS ARE SHOWN IN PLAN ONLY.
3. THERE SHALL BE NO OPEN CUTTING OF VDOT PAVEMENT ALONG RAPPAHANNOCK
DR., SHADY LA., OR BEACH RD. ALL FORCEMAINS, LATERALS AND MHC'S SHALL BE
DIRECTIONALLY DRILLED OR INSTALLED IN ENCASEMENT PIPE (AS NOTED) UNDER
PAVEMENT ON THOSE ROADS.
4. REFER TO SHEET C-35 FOR FLUSHING CONNECTION AND TERMINAL FLUSHING
DETAILS.
5. CASING PIPE SHALL EXTEND BEHIND DITCH WHEN CROSSING ROADWAY.
6. A MINIMUM OF 10' MUST BE MAINTAINED BETWEEN PRIVATE WELLS AND
FORCEMAINS.
7. EXISTING WATER LINES SHOWN ON THE PLANS ARE BASED UPON SCHEMATIC
RECORDS AND MAY NOT REFLECT THEIR ACTUAL LOCATION. CONTRACTOR SHALL
MAINTAIN 10-FOOT MINIMUM HORIZONTAL AND 18-INCH VERTICAL SEPARATIONS
BETWEEN EXISTING WATER LINES AND PROPOSED FORCE MAINS.
8. CONTRACTOR SHALL DIG TEST PITS AT THREE LOCATIONS ALONG RAPPAHANNOCK
DR. TO DETERMINE THE LOCATION OF THE EXISTING 4" WATER LINE. NOTIFY
OWNER AND ENGINEER IF MAINTAINING 10-FOOT SEPARATION FROM PROPOSED
FORCE MAIN IS NOT POSSIBLE.
9. CONTRACTOR SHALL ENSURE LINES ARE LOCATED LONGITUDINALLY AT THE BACK
OF THE SHOULDER, 4-FEET FROM THE EDGE OF PAVEMENT, WHICHEVER IS
GREATER, OR NEAR THE RIGHT-OF-WAY LINE WHERE POSSIBLE.
P:\8271 - White Stone\8271-01-005 (ENG) - WW Phase 2 Design Phase\Engineering\Engineering Plans\8271-01-005-PNP.dwg
RA
PP
AH
AN
NO
CK
D R.
M
AR
Y
BA
LL
R D.
GRAPHIC SCALE
( IN FEET )
1 inch = ft.50
CO
NN
EC
T
TO
E
X.
6"
F .M
6" x2 " W
YE
ST
A=
+0
0.0
2" G
AT
E
VA
LV
E 2"
° B
EN
D
ST
A=
+0
3.6
EX. GROUND
3'
MI
N.
2" HDPE FORCE MAIN
AI
R
RE
LE
AS
E
VA
LV
E
TE
RM
IN
AL
F
LU
SH
IN
G
CO
NN
EN
D 2"
F .M
ST
A=
+0
0.0
EX. 18" RCP CULVERT
" M
IN
TEST PIT
REQUIRED
POSSIBLE WATER
SERVICE
" M
IN
STA 10+03.64
2" GATE VALVE
2" 45° BEND
N=3,765,874.97 E=12,093,077.54
STA 19+00.00
AIR RELEASE VALVE
TERMINAL FLUSHING CONN.
END 2" F.M.
N=3,765,390.90 E=12,092,323.13
POSSIBLE WATER
SERVICE, TEST
PIT REQUIRED
EX. 6" PHASE 1
FORCE MAIN
STA 11+21
SERVICE TEE
STA 13+46
SERVICE TEE
STA 14+40
SERVICE TEE
STA 18+90
SERVICE TEE
CONNECT NEW
SERVICE TO
EX. PH1 6"FM
CONNECT NEW
SERVICES TO
EX. PH1 6"FM
STA 10+00.00
CONNECT TO EX. 6" F.M.
6"x2" WYE N=3,765,878.53 E=12,093,078.32
AVOID EX. WATER METER
TO
W
N O
F W
H
IT
E S
TO
N
E S
E W
A G
E C
O
LL
E C
TI
O
N
T R
E A
TM
E
N T
- P H
A S
E
LA
N
C A
S T
E R
C O
U N
T Y
V
IR
G
IN
IA
B ow m an
C on su lti ng G ro up
, L td
P ho ne
7)
-1
F ax
7)
-4 w w w .b ow m an co ns ul tin g.
co m
B ow m an
C on su lti ng G ro up
, L td
M cL aw s C irc le
S ui te
W ill ia m sb ur g, V irg in ia
PROJECTNO
TCW/DWD DWD RJK
OCT. 8, 2021
8271-01-005-XXX
8271-01-005
RAPPAHANNOCK DR. - S.R. 3
10+0011+0012+0013+0014+0015+0017+00 16+00
PROFILE - RAPPAHANNOCK DR. CONNECTION TO PHASE 1
18+0019+0020+00
P:\8271 - White Stone\8271-01-005 (ENG) - WW Phase 2 Design Phase\Engineering\Engineering Plans\8271-01-005-PNP.dwg
RA
PP
AH
AN
NO
CK
D R.
C O
NN
EC
TI
O
N
TO
P
HA
SE
GRAPHIC SCALE
( IN FEET )
1 inch = ft.50
NOTES:
1. SHEETS C-5 THROUGH C-19 REFER TO ALIGNMENT FOR THE MAIN SYSTEM
FORCEMAINS. REFER TO SHEETS C-20 THROUGH C-32 FOR GRINDER PUMPS,
LATERALS AND MULTI-HOUSE COLLECTORS (MHC).
2. SERVICE TEES SHOWN IN PROFILE FOR MHC'S AND FORCEMAIN. TEES FOR
SERVICE LATERALS ARE SHOWN IN PLAN ONLY.
3. THERE SHALL BE NO OPEN CUTTING OF VDOT PAVEMENT ALONG RAPPAHANNOCK
DR., SHADY LA., OR BEACH RD. ALL FORCEMAINS, LATERALS AND MHC'S SHALL BE
DIRECTIONALLY DRILLED OR INSTALLED IN ENCASEMENT PIPE (AS NOTED) UNDER
PAVEMENT ON THOSE ROADS.
4. REFER TO SHEET C-35 FOR FLUSHING CONNECTION AND TERMINAL FLUSHING
DETAILS.
5. CASING PIPE SHALL EXTEND BEHIND DITCH WHEN CROSSING ROADWAY.
6. A MINIMUM OF 10' MUST BE MAINTAINED BETWEEN PRIVATE WELLS AND
FORCEMAINS.
7. EXISTING WATER LINES SHOWN ON THE PLANS ARE BASED UPON SCHEMATIC
RECORDS AND MAY NOT REFLECT THEIR ACTUAL LOCATION. CONTRACTOR SHALL
MAINTAIN 10-FOOT MINIMUM HORIZONTAL AND 18-INCH VERTICAL SEPARATIONS
BETWEEN EXISTING WATER LINES AND PROPOSED FORCE MAINS.
8. CONTRACTOR SHALL DIG TEST PITS AT THREE LOCATIONS ALONG RAPPAHANNOCK
DR. TO DETERMINE THE LOCATION OF THE EXISTING 4" WATER LINE. NOTIFY
OWNER AND ENGINEER IF MAINTAINING 10-FOOT SEPARATION FROM PROPOSED
FORCE MAIN IS NOT POSSIBLE.
9. CONTRACTOR SHALL ENSURE LINES ARE LOCATED LONGITUDINALLY AT THE BACK
OF THE SHOULDER, 4-FEET FROM THE EDGE OF PAVEMENT, WHICHEVER IS
GREATER, OR NEAR THE RIGHT-OF-WAY LINE WHERE POSSIBLE.
3"
° B
EN
D
ST
A=
+3 9.4
3"
° B
EN
D
ST
A=
+3 4.3
3"
° B
EN
D
ST
A=
+1 4.3
3"
° B
EN
D
ST
A=
+0 9.1
3"
° B
EN
D
ST
A=
+5 6.8
3"
° B
EN
D
ST
A=
+5 4.0
3"
° B
EN
D
ST
A=
+3 1.9
3"
° B
EN
D
ST
A=
+2 9.1
3"
° B
EN
D
ST
A=
+4 9.0
3"
° B
EN
D
ST
A=
+4 7.3
3"
° B
EN
D
ST
A=
+4
7.3
3"
° B
EN
D
ST
A=
+0 1.2
3"
° B
EN
D
ST
A=
+9 8.5
3"
° B
EN
D
ST
A=
+2 8.5
3"
° B
EN
D
ST
A=
+2 5.9
ST
A
+5 1.5
6 S
HA
DY
LA
NE
3" T
EE
3" x2 " R
ED
UC
ER
(N
W
(2 ) 3
" G
AT
E
VA
LV
ES
2" G
AT
E
VA
LV
E
ST
A=
+0
0.0
3'
MI
N.
3" HDPE FORCE MAIN
3"
° B
EN
D
ST
A=
+3 2.0
3"
° B
EN
D
ST
A=
+4
9.7
TEST PIT
REQUIRED
POSSIBLE WATER SERVICE
" M
IN
STA 10+00.00
= STA 24+51.56 SHADY LANE.
3" TEE
3"x2" REDUCER (NW)
(2) 3" GATE VALVES
2" GATE VALVE
N=3,764,904.30 E=12,092,623.60
STA 11+25.91
3" 45° BEND
N=3,764,803.74 E=12,092,556.01
STA 11+28.57
3" 45° BEND
N=3,764,801.10 E=12,092,556.23
STA 11+98.57
3" 45° BEND
N=3,764,747.78 E=12,092,510.87
STA 12+01.22
3" 45° BEND
N=3,764,747.56 E=12,092,508.22
STA 12+47.37
3" 45° BEND
N=3,764,712.41 E=12,092,478.32
STA 12+49.08
3" 45° BEND
N=3,764,710.71 E=12,092,478.46
STA 14+29.13
3" 45° BEND
N=3,764,574.35 E=12,092,360.89
STA 14+31.95
3" 45° BEND
N=3,764,571.53
E=12,092,361.12
STA 14+54.00
3" 45° BEND
N=3,764,557.25 E=12,092,377.91
STA 14+56.83
3" 45° BEND
N=3,764,554.43 E=12,092,378.14
STA 16+09.18
3" 45° BEND
N=3,764,438.44 E=12,092,279.35
STA 16+14.31
3" 45° BEND
N=3,764,433.34 E=12,092,279.76
STA 16+34.31
3" 45° BEND
N=3,764,418.11 E=12,092,266.79
STA 16+39.43
3" 45° BEND
N=3,764,417.70 E=12,092,261.69
STA 10+32.00
3" 45° BEND
N=3,764,879.40
E=12,092,603.50POSSIBLE WATER SERVICE,
TEST PIT REQUIRED
PROPOSED
PERMANENT
UTILITY EASEMENT
STA 22+98
SERVICE TEE
STA 21+63
SERVICE TEE
STA 20+07
SERVICE TEE
STA 17+89
SERVICE TEE
STA 15+93
SERVICE TEE
STA 12+21
SERVICE TEE
STA 10+99
SERVICE TEE
STA 10+97
SERVICE TEE
STA 10+49.73
3" 45° BEND
N=3,764,861.77 E=12,092,605.37
STA 10+89
SERVICE TEE
STA 13+66
SERVICE TEE
TO
W
N O
F W
H
IT
E S
TO
N
E S
E W
A G
E C
O
LL
E C
TI
O
N
T R
E A
TM
E
N T
- P H
A S
E
LA
N
C A
S T
E R
C O
U N
T Y
V
IR
G
IN
IA
B ow m an
C on su lti ng G ro up
, L td
P ho ne
7)
-1
F ax
7)
-4 w w w .b ow m an co ns ul tin g.
co m
B ow m an
C on su lti ng G ro up
, L td
M cL aw s C irc le
S ui te
W ill ia m sb ur g, V irg in ia
PROJECTNO
TCW/DWD DWD RJK
OCT. 8, 2021
8271-01-005-XXX
8271-01-005
CHERRY POINT DR. - S.R. 638 BOLES AVE.S.R. 1204
SH
AD
Y LA. - S.R
. 652
ST
A.
4+
M
AT
C H
L
IN
E
- S
EE
S
H
EE
T C
-6
BOLES AVE. F.M.,
SEE SHEET C-8
SHADY LA. F.M.,
SEE SHEET C-11
10+0011+0012+0013+0014+0015+0017+0018+0019+0020+0021+0022+0023+0024+00 16+00
ST
A.
4+
M
AT
C H
L
IN
E
- S
EE
S
H
EE
T C
-6
PROFILE - CHERRY POINT DR. - STA. 10+00 TO 24+00
SH
AD
Y LA. - S.R
. 638
P:\8271 - White Stone\8271-01-005 (ENG) - WW Phase 2 Design Phase\Engineering\Engineering Plans\8271-01-005-PNP.dwg
CH
ER
RY
P
O
IN
T
DR
S
TA
. 1
0+
T O
4+
GRAPHIC SCALE
( IN FEET )
1 inch = ft.50
NOTES:
1. SHEETS C-5 THROUGH C-19 REFER TO ALIGNMENT FOR THE MAIN SYSTEM
FORCEMAINS. REFER TO SHEETS C-20 THROUGH C-32 FOR GRINDER PUMPS,
LATERALS AND MULTI-HOUSE COLLECTORS (MHC).
2. SERVICE TEES SHOWN IN PROFILE FOR MHC'S AND FORCEMAIN. WYES FOR
SERVICE LATERALS ARE SHOWN IN PLAN ONLY.
3. THERE SHALL BE NO OPEN CUTTING OF VDOT PAVEMENT ALONG RAPPAHANNOCK
DR., SHADY LA., OR BEACH RD. ALL FORCEMAINS, LATERALS AND MHC'S SHALL BE
DIRECTIONALLY DRILLED OR INSTALLED IN ENCASEMENT PIPE (AS NOTED) UNDER
PAVEMENT ON THOSE ROADS.
4. REFER TO SHEET C-35 FOR FLUSHING CONNECTION AND TERMINAL FLUSHING
DETAILS.
5. CASING PIPE SHALL EXTEND BEHIND DITCH WHEN CROSSING ROADWAY.
6. A MINIMUM OF 10' MUST BE MAINTAINED BETWEEN PRIVATE WELLS AND
FORCEMAINS.
7. EXISTING WATER LINES SHOWN ON THE PLANS ARE BASED UPON SCHEMATIC
RECORDS AND MAY NOT REFLECT THEIR ACTUAL LOCATION. CONTRACTOR SHALL
MAINTAIN 10-FOOT MINIMUM HORIZONTAL AND 18-INCH VERTICAL SEPARATIONS
BETWEEN EXISTING WATER LINES AND PROPOSED FORCE MAINS.
8. CONTRACTOR SHALL ENSURE LINES ARE LOCATED LONGITUDINALLY AT THE BACK
STA 24+70.99
= STA 10+00 SHELTON DR.
3"x2" TEE
(2) 3" GATE VALVES
(1) 2" GATE VALVE
N=3,763,784.62
E=12,091,722.51
STA 34+75.00
AIR RELEASE VALVE
TERMINAL FLUSHING CONN.
END 3" FORCE MAIN
N=3,763,020.26 E=12,091,071.52
STA 30+03.85
2" MHC
3"x2" TEE
(2) 3" GATE VALVES
2" GATE VALVE
N=3,763,378.95 E=12,091,377.01
STA 34+47.21
2" MHC
3"x2" TEE
(2) 3" GATE VALVES
2" GATE VALVE
N=3,763,041.41 E=12,091,089.54
STA 29+05
SERVICE TEE
STA 32+94
SERVICE TEE
STA 26+62
SERVICE TEE
STA 27+37
SERVICE TEE
EX. GROUND
AI
R
RE
LE
AS
E
VA
LV
E
TE
RM
IN
AL
F
LU
SH
IN
G
CO
NN
EN
D 3"
F
OR
CE
M
AI
N
ST
A=
+7
5.0
ST
A
+0 0 S
HE
LT
ON
D
R.
3" x2 " T
EE
(2
) 3 " G
AT
E
VA
LV
ES
(1
) 2 " G
AT
E
VA
LV
E
ST
A=
+7
0.9
3'
MI
N.
3" HDPE FORCE MAIN
2" M
HC
3" x2 " T
EE
(2
) 3 " G
AT
E
VA
LV
ES
2"
G
AT
E
VA
LV
E
ST
A=
+4
7.2
2" M
HC
3" x2 " T
EE
(2
) 3 " G
AT
E
VA
LV
ES
2"
G
AT
E
VA
LV
E
ST
A=
+0
3.8
TO
W
N O
F W
H
IT
E S
TO
N
E S
E W
A G
E C
O
LL
E C
TI
O
N
T R
E A
TM
E
N T
- P H
A S
E
LA
N
C A
S T
E R
C O
U N
T Y
V
IR
G
IN
IA
B ow m an
C on su lti ng G ro up
, L td
P ho ne
7)
-1
F ax
7)
-4 w w w .b ow m an co ns ul tin g.
co m
B ow m an
C on su lti ng G ro up
, L td
M cL aw s C irc le
S ui te
W ill ia m sb ur g, V irg in ia
PROJECTNO
TCW/DWD DWD RJK
OCT. 8, 2021
8271-01-005-XXX
8271-01-005
CHERRY POINT DR. - S.R. 638
SH
ELTO
N D
R
FO
R
ES
T
H
AV
EN
D
R
S .R
. 1
M
YW
AY
L
A.
ST
A.
4+
M
AT
C H
L
IN
E
- S
EE
S
H
EE
T C
-5
SHELTON DR. F.M., SEE SHEET C-7
24+0025+0026+0027+0028+0029+0031+0032+0033+0034+0035+00 30+00
ST
A.
4+
M
AT
C H
L
IN
E
- S
EE
S
H
EE
T C
-5
PROFILE - CHERRY POINT DR. - STA. 24+00 TO 35+50
P:\8271 - White Stone\8271-01-005 (ENG) - WW Phase 2 Design Phase\Engineering\Engineering Plans\8271-01-005-PNP.dwg
CH
ER
RY
P
O
IN
T
DR
S
TA
. 2
4+
T O
5+
GRAPHIC SCALE
( IN FEET )
1 inch = ft.50
NOTES:
1. SHEETS C-5 THROUGH C-19 REFER TO ALIGNMENT FOR THE MAIN SYSTEM
FORCEMAINS. REFER TO SHEETS C-20 THROUGH C-32 FOR GRINDER PUMPS,
LATERALS AND MULTI-HOUSE COLLECTORS (MHC).
2. SERVICE TEES SHOWN IN PROFILE FOR MHC'S AND FORCEMAIN. WYES FOR
SERVICE LATERALS ARE SHOWN IN PLAN ONLY.
3. THERE SHALL BE NO OPEN CUTTING OF VDOT PAVEMENT ALONG RAPPAHANNOCK
DR., SHADY LA., OR BEACH RD. ALL FORCEMAINS, LATERALS AND MHC'S SHALL BE
DIRECTIONALLY DRILLED OR INSTALLED IN ENCASEMENT PIPE (AS NOTED) UNDER
PAVEMENT ON THOSE ROADS.
4. REFER TO SHEET C-35 FOR FLUSHING CONNECTION AND TERMINAL FLUSHING
DETAILS.
5. CASING PIPE SHALL EXTEND BEHIND DITCH WHEN CROSSING ROADWAY.
6. A MINIMUM OF 10' MUST BE MAINTAINED BETWEEN PRIVATE WELLS AND
FORCEMAINS.
7. EXISTING WATER LINES SHOWN ON THE PLANS ARE BASED UPON SCHEMATIC
RECORDS AND MAY NOT REFLECT THEIR ACTUAL LOCATION. CONTRACTOR SHALL
MAINTAIN 10-FOOT MINIMUM HORIZONTAL AND 18-INCH VERTICAL SEPARATIONS
BETWEEN EXISTING WATER LINES AND PROPOSED FORCE MAINS.
8. CONTRACTOR SHALL ENSURE LINES ARE LOCATED LONGITUDINALLY AT THE BACK
STA 10+00.00
= STA 24+66.31 CHERRY POINT DR.
3"x2" TEE
(2) 3" GATE VALVES
(1) 2" GATE VALVE
N=3,763,784.62
E=12,091,722.51STA 10+32.91
2" 45° BEND
N=3,763,806.11
E=12,091,697.58
STA 10+52.69
2" 45° BEND
N=3,763,825.81 E=12,091,695.78
STA 11+81.99
BEGIN 1,000'R CURVE
N=3,763,910.63 E=12,091,598.19
STA 12+03.26
END 1,000'R CURVE
N=3,763,924.41
E=12,091,581.99STA 13+42.23
BEGIN 1,000'R CURVE
N=3,764,013.33 E=12,091,475.18
STA 13+77.06
END 1,000'R CURVE
N=3,764,035.14 E=12,091,448.03
STA 14+86.92
2" 11.25° BEND
N=3,764,102.44
E=12,091,361.21
STA 15+25.00
TERMINAL FLUSHING CONN.
END 2" FORCE MAIN
N=3,764,119.45
E=12,091,327.13
PROPOSED 10' PERMANENT
UTILITY EASEMENT
STA 15+18
SERVICE TEE
STA 15+14
SERVICE TEE
STA 13+69
SERVICE TEE
STA 12+83
SERVICE TEE
EX. GROUND
ST
A
+6 6.3
1 C
HE
RR
Y
PO
IN
T
DR
3" x2 " T
EE
(2
) 3 " G
AT
E
VA
LV
ES
(1
) 2 " G
AT
E
VA
LV
E
ST
A=
+0
0.0
2"
° B
EN
D
ST
A=
+3 2.9
2"
° B
EN
D
ST
A=
+5
2.6
BE
GI
N 1,0
'R
C
UR
VE
ST
A=
+8 1.9
EN
D 1,0
'R
C
UR
VE
ST
A=
+0 3.2
BE
GI
N 1,0
'R
C
UR
VE
ST
A=
+4 2.2
EN
D
1,0
'R C
UR
VE
ST
A=
+7
7.0
2"
.25 ° B
EN
D
ST
A=
+8
6.9
TE
RM
IN
AL
F
LU
SH
IN
G
CO
NN
EN
D
2" F
OR
CE
M
AI
N
ST
A=
+2
5.0
3'
MI
N.
2" HDPE FORCE MAIN
TO
W
N O
F W
H
IT
E S
TO
N
E S
E W
A G
E C
O
LL
E C
TI
O
N
T R
E A
TM
E
N T
- P H
A S
E
LA
N
C A
S T
E R
C O
U N
T Y
V
IR
G
IN
IA
B ow m an
C on su lti ng G ro up
, L td
P ho ne
7)
-1
F ax
7)
-4 w w w .b ow m an co ns ul tin g.
co m
B ow m an
C on su lti ng G ro up
, L td
M cL aw s C irc le
S ui te
W ill ia m sb ur g, V irg in ia
PROJECTNO
TCW/DWD DWD RJK
OCT. 8, 2021
8271-01-005-XXX
8271-01-005
C H
ER
R
Y
PO
IN
T
D R
S
.R . 6
SHELTON DR.
CHERRY POINT DR. F.M., SEE SHEET C-6
10+0011+0012+0013+0014+0015+00
PROFILE - SHELTON DR.
50 50
P:\8271 - White Stone\8271-01-005 (ENG) - WW Phase 2 Design Phase\Engineering\Engineering Plans\8271-01-005-PNP.dwg
SH
EL
TO
N
DR
GRAPHIC SCALE
( IN FEET )
1 inch = ft.50
NOTES:
1. SHEETS C-5 THROUGH C-19 REFER TO ALIGNMENT FOR THE MAIN SYSTEM
FORCEMAINS. REFER TO SHEETS C-20 THROUGH C-32 FOR GRINDER PUMPS,
LATERALS AND MULTI-HOUSE COLLECTORS (MHC).
2. SERVICE TEES SHOWN IN PROFILE FOR MHC'S AND FORCEMAIN. WYES FOR
SERVICE LATERALS ARE SHOWN IN PLAN ONLY.
3. THERE SHALL BE NO OPEN CUTTING OF VDOT PAVEMENT ALONG RAPPAHANNOCK
DR., SHADY LA., OR BEACH RD. ALL FORCEMAINS, LATERALS AND MHC'S SHALL BE
DIRECTIONALLY DRILLED OR INSTALLED IN ENCASEMENT PIPE (AS NOTED) UNDER
PAVEMENT ON THOSE ROADS.
4. REFER TO SHEET C-35 FOR FLUSHING CONNECTION AND TERMINAL FLUSHING
DETAILS.
5. CASING PIPE SHALL EXTEND BEHIND DITCH WHEN CROSSING ROADWAY.
6. A MINIMUM OF 10' MUST BE MAINTAINED BETWEEN PRIVATE WELLS AND
FORCEMAINS.
7. EXISTING WATER LINES SHOWN ON THE PLANS ARE BASED UPON SCHEMATIC
RECORDS AND MAY NOT REFLECT THEIR ACTUAL LOCATION. CONTRACTOR SHALL
MAINTAIN 10-FOOT MINIMUM HORIZONTAL AND 18-INCH VERTICAL SEPARATIONS
BETWEEN EXISTING WATER LINES AND PROPOSED FORCE MAINS.
8. CONTRACTOR SHALL ENSURE LINES ARE LOCATED LONGITUDINALLY AT THE BACK
= STA 23+55.73 SHADY LANE
3"x2" TEE
(2) 3" GATE VALVES
2" GATE VALVE
N=3,764,871.49
E=12,092,706.16
STA 10+38.77
2" 45° BEND
N=3,764,900.83 E=12,092,731.49
STA 10+44.42
2" 45° BEND
BEGIN 30'R CURVE
N=3,764,906.47 E=12,092,731.08
STA 10+96.72
END 30'R CURVE
N=3,764,952.39 E=12,092,731.68
TEST PIT REQUIRED
PROPOSED PERMANENT
UTILITY EASEMENT
STA 15+39
SERVICE TEE
STA 16+57
SERVICE TEE
STA 14+36
SERVICE TEE
EX. GROUND
ST
A
+5 5.7
3 S
HA
DY
LA
NE
3" x2 " T
EE
(2
) 3 " G
AT
E
VA
LV
ES
2"
G
AT
E
VA
LV
E
ST
A=
+0
0.0
2"
° B
EN
D
ST
A=
+3 8.7
2"
° B
EN
D
BE
GI
N
'R
C
UR
VE
ST
A=
+4
4.4
EN
D
'R
C
UR
VE
ST
A=
+9 6.7
3'
MI
N.
2" HDPE FORCE MAIN
TEST PIT
REQUIRED
EX. 8" W.L.
18" MIN.
TO
W
N O
F W
H
IT
E S
TO
N
E S
E W
A G
E C
O
LL
E C
TI
O
N
T R
E A
TM
E
N T
- P H
A S
E
LA
N
C A
S T
E R
C O
U N
T Y
V
IR
G
IN
IA
B ow m an
C on su lti ng G ro up
, L td
P ho ne
7)
-1
F ax
7)
-4 w w w .b ow m an co ns ul tin g.
co m
B ow m an
C on su lti ng G ro up
, L td
M cL aw s C irc le
S ui te
W ill ia m sb ur g, V irg in ia
PROJECTNO
TCW/DWD DWD RJK
OCT. 8, 2021
8271-01-005-XXX
8271-01-005
CHERRY POINT DR. - S.R. 638
SH
AD
Y LA. - S.R
. 638
BOLES AVE. - S.R. 1204
SH
AD
Y LA. - S.R
. 652
ST
A.
8+
M
AT
C H
L
IN
E
- S
EE
S
H
EE
T C
-9
SHADY LA. F.M., SEE SEE SHEET C-11
CHERRY POINT DR. F.M.,
SEE SHEET C-5
10+00 11+00 12+00 13+00 14+00 15+00 17+00 18+0016+00
ST
A.
8+
M
AT
C H
L
IN
E
- S
EE
S
H
EE
T C
-9
PROFILE - BOLES AVE. - STA. 10+00 TO 18+00
P:\8271 - White Stone\8271-01-005 (ENG) - WW Phase 2 Design Phase\Engineering\Engineering Plans\8271-01-005-PNP.dwg
BO
LE
S
AV
E.
ST
A.
0+
T
O
8+
GRAPHIC SCALE
( IN FEET )
1 inch = ft.50
NOTES:
1. SHEETS C-5 THROUGH C-19 REFER TO ALIGNMENT FOR THE MAIN SYSTEM
FORCEMAINS. REFER TO SHEETS C-20 THROUGH C-32 FOR GRINDER PUMPS,
LATERALS AND MULTI-HOUSE COLLECTORS (MHC).
2. SERVICE TEES SHOWN IN PROFILE FOR MHC'S AND FORCEMAIN. WYES FOR
SERVICE LATERALS ARE SHOWN IN PLAN ONLY.
3. THERE SHALL BE NO OPEN CUTTING OF VDOT PAVEMENT ALONG RAPPAHANNOCK
DR., SHADY LA., OR BEACH RD. ALL FORCEMAINS, LATERALS AND MHC'S SHALL BE
DIRECTIONALLY DRILLED OR INSTALLED IN ENCASEMENT PIPE (AS NOTED) UNDER
PAVEMENT ON THOSE ROADS.
4. REFER TO SHEET C-35 FOR FLUSHING CONNECTION AND TERMINAL FLUSHING
DETAILS.
5. CASING PIPE SHALL EXTEND BEHIND DITCH WHEN CROSSING ROADWAY.
6. A MINIMUM OF 10' MUST BE MAINTAINED BETWEEN PRIVATE WELLS AND
FORCEMAINS.
7. EXISTING WATER LINES SHOWN ON THE PLANS ARE BASED UPON SCHEMATIC
RECORDS AND MAY NOT REFLECT THEIR ACTUAL LOCATION. CONTRACTOR SHALL
MAINTAIN 10-FOOT MINIMUM HORIZONTAL AND 18-INCH VERTICAL SEPARATIONS
BETWEEN EXISTING WATER LINES AND PROPOSED FORCE MAINS.
8. CONTRACTOR SHALL ENSURE LINES ARE LOCATED LONGITUDINALLY AT THE BACK
OF THE SHOULDER, 4-FEET FROM THE EDGE OF PAVEMENT, WHICHEVER IS
GREATER, OR NEAR THE RIGHT-OF-WAY LINE WHERE POSSIBLE.
PROPOSED
PERMANENT
EASEMENT
STA 26+00.00
AIR RELEASE VALVE
TERMINAL FLUSHING CONN.
END 2" FORCE MAIN
N=3,765,904.74 E=12,093,894.81
STA 21+39
SERVICE TEE
STA 21+49
SERVICE TEE STA 23+39
SERVICE TEE
STA 25+52
SERVICE TEE
EX. GROUND
AI
R
RE
LE
AS
E
VA
LV
E
TE
RM
IN
AL
F
LU
SH
IN
G
CO
NN
EN
D 2"
F
OR
CE
M
AI
N
ST
A=
+0
0.0
3'
MI
N.
2" HDPE FORCE MAIN
TO
W
N O
F W
H
IT
E S
TO
N
E S
E W
A G
E C
O
LL
E C
TI
O
N
T R
E A
TM
E
N T
- P H
A S
E
LA
N
C A
S T
E R
C O
U N
T Y
V
IR
G
IN
IA
B ow m an
C on su lti ng G ro up
, L td
P ho ne
7)
-1
F ax
7)
-4 w w w .b ow m an co ns ul tin g.
co m
B ow m an
C on su lti ng G ro up
, L td
M cL aw s C irc le
S ui te
W ill ia m sb ur g, V irg in ia
PROJECTNO
TCW/DWD DWD RJK
OCT. 8, 2021
8271-01-005-XXX
8271-01-005
BOLES AVE. - S.R. 1204
ST
A.
8+
M
AT
C H
L
IN
E
- S
EE
S
H
EE
T C
-8
18+00 19+00 20+00 21+00 22+00 23+00 25+00 26+0024+00
ST
A.
8+
M
AT
C H
L
IN
E
- S
EE
S
H
EE
T C
-8
PROFILE - BOLES AVE. - STA. 18+00 TO 27+00
P:\8271 - White Stone\8271-01-005 (ENG) - WW Phase 2 Design Phase\Engineering\Engineering Plans\8271-01-005-PNP.dwg
BO
LE
S
AV
E.
ST
A.
8+
T
O
7+
GRAPHIC SCALE
( IN FEET )
1 inch = ft.50
NOTES:
1. SHEETS C-5 THROUGH C-19 REFER TO ALIGNMENT FOR THE MAIN SYSTEM
FORCEMAINS. REFER TO SHEETS C-20 THROUGH C-32 FOR GRINDER PUMPS,
LATERALS AND MULTI-HOUSE COLLECTORS (MHC).
2. SERVICE TEES SHOWN IN PROFILE FOR MHC'S AND FORCEMAIN. WYES FOR
SERVICE LATERALS ARE SHOWN IN PLAN ONLY.
3. THERE SHALL BE NO OPEN CUTTING OF VDOT PAVEMENT ALONG RAPPAHANNOCK
DR., SHADY LA., OR BEACH RD. ALL FORCEMAINS, LATERALS AND MHC'S SHALL BE
DIRECTIONALLY DRILLED OR INSTALLED IN ENCASEMENT PIPE (AS NOTED) UNDER
PAVEMENT ON THOSE ROADS.
4. REFER TO SHEET C-35 FOR FLUSHING CONNECTION AND TERMINAL FLUSHING
DETAILS.
5. CASING PIPE SHALL EXTEND BEHIND DITCH WHEN CROSSING ROADWAY.
6. A MINIMUM OF 10' MUST BE MAINTAINED BETWEEN PRIVATE WELLS AND
FORCEMAINS.
7. EXISTING WATER LINES SHOWN ON THE PLANS ARE BASED UPON SCHEMATIC
RECORDS AND MAY NOT REFLECT THEIR ACTUAL LOCATION. CONTRACTOR SHALL
MAINTAIN 10-FOOT MINIMUM HORIZONTAL AND 18-INCH VERTICAL SEPARATIONS
BETWEEN EXISTING WATER LINES AND PROPOSED FORCE MAINS.
8. CONTRACTOR SHALL ENSURE LINES ARE LOCATED LONGITUDINALLY AT THE BACK
SEE NOTE 9 STA 10+00.00
= STA 31+08.03 BEACH RD.
4" TEE
4"x3" REDUCER (SW)
(2) 4" GATE VALVES
3" GATE VALVE
N=3,763,967.58 E=12,093,691.96
STA 10+49.20
4" 45° BEND
ROTATED VERT.
N=3,763,998.42
E=12,093,653.63
STA 11+08.99
4" 45° BEND
ROTATED VERT.
N=3,764,058.05
E=12,093,649.23
STA 12+88.12
4" 45° BEND
N=3,764,175.05 E=12,093,513.59
STA 12+90.38
4" 45° BEND
N=3,764,177.30 E=12,093,513.42
STA 13+10.38
4" 45° BEND
N=3,764,190.37 E=12,093,498.28
STA 13+12.63
4" 45° BEND
N=3,764,190.20 E=12,093,496.02
STA 16+14.59
= STA 10+00 DAWSON AVE.
4"x2" TEE 4"x3" REDUCER (NW)
4" GATE VALVE
3" GATE VALVE
2" GATE VALVE
N=3,764,387.42
E=12,093,267.37
34 L.F. 12"
ENCASEMENT PIPE
PER VDOT EP-1 DETAIL
ON SHEET C-34
TEST PIT REQUIRED
POSSIBLE WATER SERVICE,
TEST PIT REQUIRED
POSSIBLE WATER SERVICE,
TEST PIT REQUIRED
PROPOSED PERMANENT
UTILITY EASEMENT
STA 11+93
SERVICE TEE
STA 13+56
SERVICE TEE
STA 16+07
SERVICE TEE
STA 18+69
SERVICE TEE
STA 13+76
SERVICE TEE
EX. GROUND
ST
A
+0 8.0
3 B
EA
CH
R
D.
4"
T
EE
4" x3
" R
ED
UC
ER
(S W
(2
) 4 " G
AT
E
VA
LV
ES
3"
G
AT
E
VA
LV
E
ST
A=
+0
0.0
4"
° B
EN
D
RO
TA
TE
D
VE
RT
ST
A=
+4
9.2
4"
° B
EN
D
RO
TA
TE
D
VE
RT
ST
A=
+0
8.9
4"
° B
EN
D
ST
A=
+8 8.1
4"
° B
EN
D
ST
A=
+9
0.3
4"
° B
EN
D
ST
A=
+1 0.3
4"
° B
EN
D
ST
A=
+1
2.6
ST
A
+0 0 D
AW
SO
N
AV
E.
4" x2 " T
EE
4" x3 " R
ED
UC
ER
(N
W
4" G
AT
E
VA
LV
E 3"
G
AT
E
VA
LV
E
2" G
AT
E
VA
LV
E
ST
A=
+1
4.5
34 L.F. 12" ENCASEMENT
PIPE UNDER BEACH RD.
PER VDOT EP-1 DETAIL
ON SHEET C-343'
MI
N.
4" HDPE FORCE MAIN3" HDPE FORCE MAIN
TEST PIT
REQUIRED
EX. 2.25" W.L.
2.4
TEST PIT
REQUIRED
POSSIBLE WATER SERVICE
TEST PIT
REQUIRED
POSSIBLE WATER SERVICE
" M
IN
" M
IN
TO
W
N O
F W
H
IT
E S
TO
N
E S
E W
A G
E C
O
LL
E C
TI
O
N
T R
E A
TM
E
N T
- P H
A S
E
LA
N
C A
S T
E R
C O
U N
T Y
V
IR
G
IN
IA
B ow m an
C on su lti ng G ro up
, L td
P ho ne
7)
-1
F ax
7)
-4 w w w .b ow m an co ns ul tin g.
co m
B ow m an
C on su lti ng G ro up
, L td
M cL aw s C irc le
S ui te
W ill ia m sb ur g, V irg in ia
PROJECTNO
TCW/DWD DWD RJK
OCT. 8, 2021
8271-01-005-XXX
8271-01-005
BE
AC
H R
D
S .R
. 6
SHADY LA. - S.R. 652
D
AW
SO
N
A
VE
S
.R . 1
ST
A.
9+
M
AT
C H
L
IN
E
- S
EE
S
H
EE
T C
-1
DAWSON AVE. F.M., SEE SHEET C-12
BEACH RD. F.M., SEE SHEET C-14
10+0011+0012+0013+0014+0015+0017+0018+0019+00 16+00
ST
A.
9+
M
AT
C H
L
IN
E
- S
EE
S
H
EE
T C
-1
PROFILE - SHADY LA. - STA. 10+00 TO 19+00
P:\8271 - White Stone\8271-01-005 (ENG) - WW Phase 2 Design Phase\Engineering\Engineering Plans\8271-01-005-PNP.dwg
SH
AD
Y
LA
S
TA
. 1
0+
T O
9+
GRAPHIC SCALE
( IN FEET )
1 inch = ft.50
NOTES:
1. SHEETS C-5 THROUGH C-19 REFER TO ALIGNMENT FOR THE MAIN SYSTEM
FORCEMAINS. REFER TO SHEETS C-20 THROUGH C-32 FOR GRINDER PUMPS,
LATERALS AND MULTI-HOUSE COLLECTORS (MHC).
2. SERVICE TEES SHOWN IN PROFILE FOR MHC'S AND FORCEMAIN. TEES FOR
SERVICE LATERALS ARE SHOWN IN PLAN ONLY.
3. THERE SHALL BE NO OPEN CUTTING OF VDOT PAVEMENT ALONG RAPPAHANNOCK
DR., SHADY LA., OR BEACH RD. ALL FORCEMAINS, LATERALS AND MHC'S SHALL BE
DIRECTIONALLY DRILLED OR INSTALLED IN ENCASEMENT PIPE (AS NOTED) UNDER
PAVEMENT ON THOSE ROADS.
4. REFER TO SHEET C-35 FOR FLUSHING CONNECTION AND TERMINAL FLUSHING
DETAILS.
5. CASING PIPE SHALL EXTEND BEHIND DITCH WHEN CROSSING ROADWAY.
6. A MINIMUM OF 10' MUST BE MAINTAINED BETWEEN PRIVATE WELLS AND
FORCEMAINS.
7. EXISTING WATER LINES SHOWN ON THE PLANS ARE BASED UPON SCHEMATIC
RECORDS AND MAY NOT REFLECT THEIR ACTUAL LOCATION. CONTRACTOR SHALL
MAINTAIN 10-FOOT MINIMUM HORIZONTAL AND 18-INCH VERTICAL SEPARATIONS
BETWEEN EXISTING WATER LINES AND PROPOSED FORCE MAINS.
8. ACCORDING TO RECORDS, THE EXISTING 2.25" WATER LINE IS ABANDONED.
LOCATION SHOWN IS APPROXIMATE (SEE NOTE 8). IF THE EX. WATER LINE
INTERFERES WITH THE INSTALLATION OF THE PROPOSED FORCE MAIN, REMOVAL
WILL BE REQUIRED.
9. CONTRACTOR SHALL ENSURE LINES ARE LOCATED LONGITUDINALLY AT THE BACK
SEE NOTE 9
STA 23+55.73
- STA 10+00 BOLES AVE.
3"x2" TEE
(2) 3" GATE VALVES
2" GATE VALVE
N=3,764,871.49 E=12,092,706.16
STA 23+75.57
3" 45° BEND
N=3,764,884.45 E=12,092,691.13
STA 24+14.23
3" 45° BEND
N=3,764,880.84 E=12,092,652.64
STA 24+51.56
= STA 10+00 CHERRY POINT DR.
3" TEE
3"x2" REDUCER (NW)
(2) 3" GATE VALVES
2" GATE VALVE
N=3,764,904.30
E=12,092,623.60
STA 24+61.49
2" 45° BEND
N=3,764,910.54 E=12,092,615.88
STA 24+92.80
2" 45° BEND
N=3,764,941.67 E=12,092,612.56
STA 25+55.18
2" 45° BEND
N=3,764,980.82 E=12,092,564.00
STA 25+63.70
2" 45° BEND
N=3,764,989.30 E=12,092,563.09
STA 26+83.70
2" 45° BEND
N=3,765,064.62 E=12,092,469.68
STA 26+92.22
2" 45° BEND
N=3,765,063.71 E=12,092,461.20
STA 28+84.94
TERMINAL FLUSHING CONN.
END 2" FORCE MAIN
N=3,765,184.67
E=12,092,311.18
STA 21+00.00
AIR RELEASE VALVE
N=3,764,704.46 E=12,092,899.81
TEST PIT
REQUIRED
POSSIBLE WATER
SERVICES, TEST
PITS REQUIRED
STA 20+67
SERVICE TEE
STA 19+71
SERVICE TEE
STA 22+41
SERVICE TEE
STA 27+91
SERVICE TEE
STA 27+89
SERVICE TEE
STA 27+38
SERVICE TEE
EX. GROUND
AI
R
RE
LE
AS
E
VA
LV
E
ST
A=
+0 0.0
- S
TA
+0
0 B
OL
ES
A
VE
3" x2
" T
EE
(2 ) 3
" G
AT
E
VA
LV
ES
2" G
AT
E
VA
LV
E
ST
A=
+5
5.7
3"
° B
EN
D
ST
A=
+7 5.5
3"
° B
EN
D
ST
A=
+1 4.2
ST
A
+0 0 C
HE
RR
Y
PO
IN
T
DR
3" T
EE
3" x2 " R
ED
UC
ER
(N
W
(2 ) 3
" G
AT
E
VA
LV
ES
2" G
AT
E
VA
LV
E
ST
A=
+5
1.5
2"
° B
EN
D
ST
A=
+6 1.4
2"
° B
EN
D
ST
A=
+9 2.8
2"
° B
EN
D
ST
A=
+5 5.1
2"
° B
EN
D
ST
A=
+6
3.7
2"
° B
EN
D
ST
A=
+8 3.7
2"
° B
EN
D
ST
A=
+9
2.2
TE
RM
IN
AL
F
LU
SH
IN
G
CO
NN
EN
D
2" F
OR
CE
M
AI
N
ST
A=
+8
4.9
3'
MI
N.
3" HDPE FORCE MAIN2" HDPE FORCE MAIN
TEST PIT
REQUIRED
EX. 2.5"
W.L.
18" MIN.
TEST PIT
REQUIRED
TEST PIT
REQUIRED
POSSIBLE WATER SERVICE.
POSSIBLE WATER SERVICE.
" M
IN
" M
IN
TO
W
N O
F W
H
IT
E S
TO
N
E S
E W
A G
E C
O
LL
E C
TI
O
N
T R
E A
TM
E
N T
- P H
A S
E
LA
N
C A
S T
E R
C O
U N
T Y
V
IR
G
IN
IA
B ow m an
C on su lti ng G ro up
, L td
P ho ne
7)
-1
F ax
7)
-4 w w w .b ow m an co ns ul tin g.
co m
B ow m an
C on su lti ng G ro up
, L td
M cL aw s C irc le
S ui te
W ill ia m sb ur g, V irg in ia
PROJECTNO
TCW/DWD DWD RJK
OCT. 8, 2021
8271-01-005-XXX
8271-01-005
SHADY LA. - S.R. 652
C H
ER
R
Y
PO
IN
T
D R
S.
R . 6
BO
LE
S
AV
E.
S.
R . 1
ST
A.
9+
M
AT
C H
L
IN
E
- S
EE
S
H
EE
T C
-1
BOLES AVE. F.M., SEE SHEET C-8
CHERRY POINT DR. F.M., SEE SHEET C-5
28+00 27+00 26+00 25+00 24+00 23+00 21+00 20+00 19+0022+00
ST
A.
9+
M
AT
C H
L
IN
E
- S
EE
S
H
EE
T C
-1
PROFILE - SHADY LA. - STA. 19+00 TO 28+60
29+00
R
AP
PA
H
AN
N
O C
K D
R
S .R
. 3
NOTES:
1. SHEETS C-5 THROUGH C-19 REFER TO ALIGNMENT FOR THE MAIN SYSTEM
FORCEMAINS. REFER TO SHEETS C-20 THROUGH C-32 FOR GRINDER PUMPS,
LATERALS AND MULTI-HOUSE COLLECTORS (MHC).
2. SERVICE TEES SHOWN IN PROFILE FOR MHC'S AND FORCEMAIN. TEES FOR
SERVICE LATERALS ARE SHOWN IN PLAN ONLY.
3. THERE SHALL BE NO OPEN CUTTING OF VDOT PAVEMENT ALONG RAPPAHANNOCK
DR., SHADY LA., OR BEACH RD. ALL FORCEMAINS, LATERALS AND MHC'S SHALL BE
DIRECTIONALLY DRILLED OR INSTALLED IN ENCASEMENT PIPE (AS NOTED) UNDER
PAVEMENT ON THOSE ROADS.
4. REFER TO SHEET C-35 FOR FLUSHING CONNECTION AND TERMINAL FLUSHING
DETAILS.
5. CASING PIPE SHALL EXTEND BEHIND DITCH WHEN CROSSING ROADWAY.
6. A MINIMUM OF 10' MUST BE MAINTAINED BETWEEN PRIVATE WELLS AND
FORCEMAINS.
7. EXISTING WATER LINES SHOWN ON THE PLANS ARE BASED UPON SCHEMATIC
RECORDS AND MAY NOT REFLECT THEIR ACTUAL LOCATION. CONTRACTOR SHALL
MAINTAIN 10-FOOT MINIMUM HORIZONTAL AND 18-INCH VERTICAL SEPARATIONS
BETWEEN EXISTING WATER LINES AND PROPOSED FORCE MAINS.
8. ACCORDING TO RECORDS, THE EXISTING 2.25" WATER LINE IS ABANDONED.
LOCATION SHOWN IS APPROXIMATE (SEE NOTE 8). IF THE EX. WATER LINE
INTERFERES WITH THE INSTALLATION OF THE PROPOSED FORCE MAIN, REMOVAL
WILL BE REQUIRED.
9. CONTRACTOR SHALL ENSURE LINES ARE LOCATED LONGITUDINALLY AT THE BACK
OF THE SHOULDER, 4-FEET FROM THE EDGE OF PAVEMENT, WHICHEVER IS
GREATER, OR NEAR THE RIGHT-OF-WAY LINE WHERE POSSIBLE.
RAPPAHANNOCK DR.
CONNECTION TO PHASE 1 F.M.,
SEE SHEET C-4
P:\8271 - White Stone\8271-01-005 (ENG) - WW Phase 2 Design Phase\Engineering\Engineering Plans\8271-01-005-PNP.dwg
SH
AD
Y
LA
S
TA
. 1
9+
T O
8+
GRAPHIC SCALE
( IN FEET )
1 inch = ft.50
PROPOSED PERMANENT
EASEMENT
PROPOSED TEMPORARY EASEMENT
= STA 16+14.59 SHADY LANE
4"x2" TEE 4"x3" REDUCER (NW)
4" GATE VALVE
3" GATE VALVE
2" GATE VALVE
N=3,764,387.42
E=12,093,267.37
STA 10+62.36
BEGIN 200'R CURVE
N=3,764,434.64 E=12,093,308.10
STA 10+70.42
END 200'R CURVE
N=3,764,440.85 E=12,093,313.24
STA 18+80.00
AIR RELEASE VALVE
TERMINAL FLUSHING CONN.
END 2" FORCE MAIN
N=3,765,074.84 E=12,093,816.71
TEST PIT REQUIRED
STA 11+02
SERVICE TEE
STA 13+31
SERVICE TEE
STA 15+25
SERVICE TEE
STA 15+62
SERVICE TEE
STA 18+74
SERVICE TEE
EX. GROUND
EX. 15" RCP CULVERT
ST
A
+1 4.5
9 S
HA
DY
LA
NE
4" x2 " T
EE
4" x3 " R
ED
UC
ER
(N
W
4" G
AT
E
VA
LV
E 3"
G
AT
E
VA
LV
E
2" G
AT
E
VA
LV
E
ST
A=
+0
0.0
BE
GI
N
0'R C
UR
VE
ST
A=
+6
2.3
EN
D
0'R
C
UR
VE
ST
A=
+7 0.4
AI
R
RE
LE
AS
E
VA
LV
E
TE
RM
IN
AL
F
LU
SH
IN
G
CO
NN
EN
D 2"
F
OR
CE
M
AI
N
ST
A=
+8
0.0
3.3
3'
MI
N.
2" HDPE FORCE MAIN
TEST PIT
REQUIRED
EX. 8" W.L.
18" MIN.
TO
W
N O
F W
H
IT
E S
TO
N
E S
E W
A G
E C
O
LL
E C
TI
O
N
T R
E A
TM
E
N T
- P H
A S
E
LA
N
C A
S T
E R
C O
U N
T Y
V
IR
G
IN
IA
B ow m an
C on su lti ng G ro up
, L td
P ho ne
7)
-1
F ax
7)
-4 w w w .b ow m an co ns ul tin g.
co m
B ow m an
C on su lti ng G ro up
, L td
M cL aw s C irc le
S ui te
W ill ia m sb ur g, V irg in ia
PROJECTNO
TCW/DWD DWD RJK
OCT. 8, 2021
8271-01-005-XXX
8271-01-005
SH
AD
Y
LA
S
.R . 6
DAWSON AVE. - S.R. 1208
SHADY LA. F.M., SEE SHEET C-10
10+00 11+00 12+00 13+00 14+00 15+00
PROFILE - DAWSON AVE.
50 50
16+00 17+00 18+00
P:\8271 - White Stone\8271-01-005 (ENG) - WW Phase 2 Design Phase\Engineering\Engineering Plans\8271-01-005-PNP.dwg
DA
W
SO
N
AV
E.
GRAPHIC SCALE
( IN FEET )
1 inch = ft.50
NOTES:
1. SHEETS C-5 THROUGH C-19 REFER TO ALIGNMENT FOR THE MAIN SYSTEM
FORCEMAINS. REFER TO SHEETS C-20 THROUGH C-32 FOR GRINDER PUMPS,
LATERALS AND MULTI-HOUSE COLLECTORS (MHC).
2. SERVICE TEES SHOWN IN PROFILE FOR MHC'S AND FORCEMAIN. WYES FOR
SERVICE LATERALS ARE SHOWN IN PLAN ONLY.
3. THERE SHALL BE NO OPEN CUTTING OF VDOT PAVEMENT ALONG RAPPAHANNOCK
DR., SHADY LA., OR BEACH RD. ALL FORCEMAINS, LATERALS AND MHC'S SHALL BE
DIRECTIONALLY DRILLED OR INSTALLED IN ENCASEMENT PIPE (AS NOTED) UNDER
PAVEMENT ON THOSE ROADS.
4. REFER TO SHEET C-35 FOR FLUSHING CONNECTION AND TERMINAL FLUSHING
DETAILS.
5. CASING PIPE SHALL EXTEND BEHIND DITCH WHEN CROSSING ROADWAY.
6. A MINIMUM OF 10' MUST BE MAINTAINED BETWEEN PRIVATE WELLS AND
FORCEMAINS.
7. EXISTING WATER LINES SHOWN ON THE PLANS ARE BASED UPON SCHEMATIC
RECORDS AND MAY NOT REFLECT THEIR ACTUAL LOCATION. CONTRACTOR SHALL
MAINTAIN 10-FOOT MINIMUM HORIZONTAL AND 18-INCH VERTICAL SEPARATIONS
BETWEEN EXISTING WATER LINES AND PROPOSED FORCE MAINS.
8. CONTRACTOR SHALL ENSURE LINES ARE LOCATED LONGITUDINALLY AT THE BACK
CONNECT TO EX.
PH1 6" F.M. WITH
6"x4" T.S. & V.
N=3,765,710.47 E=12,094,792.38
STA 10+12.66
4" 45° BEND
N=3,765,700.33 E=12,094,784.81
STA 10+15.49
4" 45° BEND
N=3,765,699.92 E=12,094,782.01
STA 10+29.30
4" 45° BEND
N=3,765,708.18 E=12,094,770.95
STA 10+32.12
4" 45° BEND
N=3,765,707.77 E=12,094,768.15
STA 10+43.78
4" 11.25° BEND
N=3,765,698.43
E=12,094,761.18
STA 10+75.21
4" 45° BEND
N=3,765,670.24 E=12,094,747.27
STA 10+78.04
4" 45° BEND
N=3,765,667.56 E=12,094,748.18
STA 10+98.04
4" 45° BEND
N=3,765,649.62 E=12,094,739.34
STA 11+00.87
4" 45° BEND
N=3,765,648.71 E=12,094,736.66
STA 13+27.83
4" 45° BEND
ROTATED VERT.
N=3,765,445.16 E=12,094,636.28
STA 13+30.66
4" 45° BEND
ROTATED VERT.
N=3,765,442.48 E=12,094,637.19
STA 13+60.68
4" 45° BEND
N=3,765,415.56 E=12,094,623.91
STA 13+63.51
4" 45° BEND
N=3,765,414.65 E=12,094,621.24
STA 15+78.18
4" 45° BEND
N=3,765,222.11 E=12,094,526.29
STA 15+86.62
4" 45° BEND
N=3,765,214.08 E=12,094,529.02
STA 15+94.81
BEGIN 2,515'R CURVE
N=3,765,206.74 E=12,094,525.40
STA 17+92.33
END 2,515'R CURVE
N=3,765,026.33 E=12,094,445.08
STA 18+90.33
BEGIN 1,175'R BEND
N=3,764,935.31 E=12,094,408.77
STA 20+38.31
END 1,175'R BEND
N=3,764,801.68 E=12,094,345.44
STA 20+65.94
4" 45° BEND
N=3,764,777.50 E=12,094,332.06
STA 20+77.82
4" 45° BEND
BEGIN 1,170'R BEND
N=3,764,774.42 E=12,094,320.58
STA 22+41.19
END 1,170'R CURVE
N=3,764,640.26 E=12,094,227.60
STA 24+73.32
4" 45° BEND
N=3,764,459.17 E=12,094,082.38
STA 24+77.56
4" 45° BEND
N=3,764,454.95 E=12,094,082.84
25 L.F. 12" ENCASEMENT PIPE
PER VDOT EP-1 DETAIL ON
SHEET C-34
STA 18+50.00
AIR RELEASE VALVE
N=3,764,972.77 E=12,094,423.71
TEST PIT
REQUIRED
TEST PIT
REQUIRED
PROPOSED 10' PERMANENT
UTILITY EASEMENT, TYP.
STA 20+80.82
= STA 10+00 BRUCE AVE.
4"x3" TEE
(2) 4" GATE VALVES
3" GATE VALVE
N=3,764,771.84
E=12,094,319.05
STA 17+55
SERVICE TEE
STA 17+86
SERVICE CROSS
STA 19+27
SERVICE TEE
STA 21+45
SERVICE TEE
STA 21+57
SERVICE TEE
STA 21+77
SERVICE TEE
STA 22+25
SERVICE TEE
STA 22+43
SERVICE TEE
STA 23+28
SERVICE TEE
STA 24+06
SERVICE TEE
STA 24+84
SERVICE TEE
STA 22+87.73
1.5" MHC
4"x1.5" TEE
(2) 4" GATE VALVES
1.5" GATE VALVE
N=3,764,603.95
E=12,094,198.48
STA 15+25
SERVICE TEE
EX. GROUND
EX. 15" RCP CULVERT
TEST PIT
REQUIRED
EX. 4" W.L.
TEST PIT
REQUIRED
EX. 2.25" W.L.
EN
D
1,1
'R B
EN
D
ST
A=
+3
8.3
4"
° B
EN
D
ST
A=
+6 5.9
4"
° B
EN
D
BE
GI
N
1,1
'R B
EN
D
ST
A=
+7
7.8
EN
D
1,1
'R C
UR
VE
ST
A=
+4
1.1
4"
° B
EN
D
ST
A=
+9 8.0
CO
NN
EC
T
TO
E
X.
PH
1 6 " F
.M . W
IT
H
6" x4
" T .S
V
ST
A=
+0
0.0
4"
° B
EN
D
ST
A=
+1 2.6
4"
° B
EN
D
ST
A=
+1
5.4
4"
° B
EN
D
ST
A=
+2 9.3
4"
° B
EN
D
ST
A=
+3
2.1
4"
.25 ° B
EN
D
ST
A=
+4
3.7
4"
° B
EN
D
ST
A=
+7 5.2
4"
° B
EN
D
ST
A=
+7
8.0
4"
° B
EN
D
ST
A=
+0 0.8
4"
° B
EN
D
RO
TA
TE
D
VE
RT
ST
A=
+2
7.8
4"
° B
EN
D
RO
TA
TE
D
VE
RT
ST
A=
+3
0.6
4"
° B
EN
D
ST
A=
+6 0.6
4"
° B
EN
D
ST
A=
+6
3.5
4"
° B
EN
D
ST
A=
+7 8.1
4"
° B
EN
D
ST
A=
+8
6.6
BE
GI
N 2,5
'R
C
UR
VE
ST
A=
+9 4.8
EN
D
2,5
'R C
UR
VE
ST
A=
+9
2.3
BE
GI
N 1,1
'R
B
EN
D
ST
A=
+9 0.3
" M
IN
25 L.F. 12" ENCASEMENT PIPE
UNDER BRUCE AVE. PER VDOT
EP-1 DETAIL ON SHEET C-34
AI
R
RE
LE
AS
E
VA
LV
E
ST
A=
+5 0.0
" M
IN
" M
IN
3'
MI
N.
4" HDPE FORCE MAIN
ST
A
+0 0 B
RU
CE
A
VE
4" x3 " T
EE
(2
) 4 " G
AT
E
VA
LV
ES
3"
G
AT
E
VA
LV
E
ST
A=
+8
0.8
1.5 " M
HC
4" x1 .5"
T
EE
(2 ) 4
" G
AT
E
VA
LV
ES
1.5 " G
AT
E
VA
LV
E
ST
A=
+8
7.7
TO
W
N O
F W
H
IT
E S
TO
N
E S
E W
A G
E C
O
LL
E C
TI
O
N
T R
E A
TM
E
N T
- P H
A S
E
LA
N
C A
S T
E R
C O
U N
T Y
V
IR
G
IN
IA
B ow m an
C on su lti ng G ro up
, L td
P ho ne
7)
-1
F ax
7)
-4 w w w .b ow m an co ns ul tin g.
co m
B ow m an
C on su lti ng G ro up
, L td
M cL aw s C irc le
S ui te
W ill ia m sb ur g, V irg in ia
PROJECTNO
TCW/DWD DWD RJK
OCT. 8, 2021
8271-01-005-XXX
8271-01-005
C H
ES
AP
EA
KE
D R
S
.R . 2
BEACH RD. - S.R. 639
BR
U
C E
AV
E.
S.
R . 1
1ST
A.
4+
M
AT
C
H L
IN
E
- S
EE
S H
EE
T
C -1
BRUCE AVE. F.M., SEE SHEET C-17 EX. PHASE 1 6" FORCE MAIN
10+0011+0012+0013+0014+0015+0017+0018+0019+00 16+00
ST
A.
4+
M
AT
C H
L
IN
E
- S
EE
S
H
EE
T C
-1
PROFILE - BEACH RD. - STA. 10+00 TO 24+00
25 25 20+0021+0022+0023+0024+00
P:\8271 - White Stone\8271-01-005 (ENG) - WW Phase 2 Design Phase\Engineering\Engineering Plans\8271-01-005-PNP.dwg
BE
AC
H
RD
S
TA
. 1
0+
T O
4+
GRAPHIC SCALE
( IN FEET )
1 inch = ft.50
NOTES:
1. SHEETS C-5 THROUGH C-19 REFER TO ALIGNMENT FOR THE MAIN SYSTEM
FORCEMAINS. REFER TO SHEETS C-20 THROUGH C-32 FOR GRINDER PUMPS,
LATERALS AND MULTI-HOUSE COLLECTORS (MHC).
2. SERVICE TEES SHOWN IN PROFILE FOR MHC'S AND FORCEMAIN. WYES FOR
SERVICE LATERALS ARE SHOWN IN PLAN ONLY.
3. THERE SHALL BE NO OPEN CUTTING OF VDOT PAVEMENT ALONG RAPPAHANNOCK
DR., SHADY LA., OR BEACH RD. ALL FORCEMAINS, LATERALS AND MHC'S SHALL BE
DIRECTIONALLY DRILLED OR INSTALLED IN ENCASEMENT PIPE (AS NOTED) UNDER
PAVEMENT ON THOSE ROADS.
4. REFER TO SHEET C-35 FOR FLUSHING CONNECTION AND TERMINAL FLUSHING
DETAILS.
5. CASING PIPE SHALL EXTEND BEHIND DITCH WHEN CROSSING ROADWAY.
6. A MINIMUM OF 10' MUST BE MAINTAINED BETWEEN PRIVATE WELLS AND
FORCEMAINS.
7. EXISTING WATER LINES SHOWN ON THE PLANS ARE BASED UPON SCHEMATIC
RECORDS AND MAY NOT REFLECT THEIR ACTUAL LOCATION. CONTRACTOR SHALL
MAINTAIN 10-FOOT MINIMUM HORIZONTAL AND 18-INCH VERTICAL SEPARATIONS
BETWEEN EXISTING WATER LINES AND PROPOSED FORCE MAINS.
8. CONTRACTOR SHALL ENSURE LINES ARE LOCATED LONGITUDINALLY AT THE BACK
STA 24+73.32
4" 45° BEND
N=3,764,459.17 E=12,094,082.38
STA 24+87.56
4" 45° BEND
N=3,764,447.15 E=12,094,076.59
STA 24+91.80
4" 45° BEND
N=3,764,446.69 E=12,094,072.37
STA 24+77.56
4" 45° BEND
N=3,764,454.95 E=12,094,082.84
STA 26+11.10
AIR RELEASE VALVE
4" 45° BEND
N=3,764,353.61
E=12,093,997.73
STA 26+71.76
4" 45° BEND
N=3,764,305.08 E=12,093,963.94
STA 26+77.42
4" 45° BEND
N=3,764,304.46 E=12,093,958.32
STA 30+53.61
4" 45° BEND
N=3,764,010.97 E=12,093,722.97
STA 30+57.86
4" 45° BEND
N=3,764,006.76 E=12,093,723.44
STA 31+08.11
= STA 10+00 SHADY LANE
4" TEE
4"x3" REDUCER (SW)
(2) 4" GATE VALVES
3" GATE VALVE
N=3,763,967.58
E=12,093,691.96
STA 31+17.86
3" 45° BEND
N=3,763,959.99 E=12,093,685.85
STA 31+22.10
3" 45° BEND
N=3,763,959.53 E=12,093,681.63
STA 35+28.30
BEGIN 795'R CURVE
N=3,763,643.03 E=12,093,427.01
STA 35+90.72
END 795'R CURVE
3" 45° BEND
N=3,763,592.92 E=12,093,389.84
STA 35+97.80
3" 45° BEND
BEGIN 800'R CURVE
N=3,763,591.56
E=12,093,382.88
STA 38+49.85
END 800'R CURVE
N=3,763,363.89 E=12,093,277.18
STA 26+16.76
4" 45° BEND
N=3,764,347.99
E=12,093,998.35STA 32+55.00
AIR RELEASE VALVE
N=3,763,855.98
E=12,093,598.33
POSSIBLE WATER SERVICE,
TEST PIT REQUIRED
STA 24+06
SERVICE TEE
STA 24+84
SERVICE TEE
STA 24+96
SERVICE TEESTA 25+66
SERVICE TEE
STA 26+99
SERVICE TEE
STA 27+09
SERVICE TEE
STA 28+98
SERVICE TEE
STA 32+98
SERVICE TEE
STA 38+00
SERVICE TEE
STA 36+87
SERVICE TEE
STA 34+79
SERVICE TEE
STA 30+97
SERVICE TEE
STA 29+98
SERVICE TEE
STA 27+46.62
1.5" MHC
4"x1.5" TEE
(2) 4" GATE VALVES
1.5" GATE VALVE
N=3,764,250.47
E=12,093,915.03
EX. GROUND
4"
° B
EN
D
ST
A=
+7 3.3
4"
° B
EN
D
ST
A=
+7
7.5
4"
° B
EN
D
ST
A=
+8 7.5
4"
° B
EN
D
ST
A=
+9
1.8
AI
R
RE
LE
AS
E
VA
LV
E 4"
° B
EN
D
ST
A=
+1
1.1
4"
° B
EN
D
ST
A=
+7 1.7
4"
° B
EN
D
ST
A=
+7
7.4
4"
° B
EN
D
ST
A=
+5 3.6
4"
° B
EN
D
ST
A=
+5
7.8
ST
A
+0 0 S
HA
DY
LA
NE
4" T
EE
4" x3 " R
ED
UC
ER
(S
W
(2 ) 4
" G
AT
E
VA
LV
ES
3" G
AT
E
VA
LV
E
ST
A=
+0
8.1
3"
° B
EN
D
ST
A=
+1 7.8
3"
° B
EN
D
ST
A=
+2
2.1
BE
GI
N
5'R C
UR
VE
ST
A=
+2
8.3
EN
D
5'R
C
UR
VE
3"
° B
EN
D
ST
A=
+9
0.7
3"
° B
EN
D
BE
GI
N
0'R
C
UR
VE
ST
A=
+9
7.8
4"
° B
EN
D
ST
A=
+1 6.7
3'
MI
N.
4" HDPE FORCE MAIN
3" HDPE FORCE MAIN
AI
R
RE
LE
AS
E
VA
LV
E
ST
A=
+5 5.0
TEST PIT
REQUIRED
POSSIBLE WATER SERVICE.
1.5 " M
HC
4" x1 .5"
T
EE
(2 ) 4
" G
AT
E
VA
LV
ES
1.5 " G
AT
E
VA
LV
E
ST
A=
+4
6.6
" M
IN
TO
W
N O
F W
H
IT
E S
TO
N
E S
E W
A G
E C
O
LL
E C
TI
O
N
T R
E A
TM
E
N T
- P H
A S
E
LA
N
C A
S T
E R
C O
U N
T Y
V
IR
G
IN
IA
B ow m an
C on su lti ng G ro up
, L td
P ho ne
7)
-1
F ax
7)
-4 w w w .b ow m an co ns ul tin g.
co m
B ow m an
C on su lti ng G ro up
, L td
M cL aw s C irc le
S ui te
W ill ia m sb ur g, V irg in ia
PROJECTNO
TCW/DWD DWD RJK
OCT. 8, 2021
8271-01-005-XXX
8271-01-005
SH
AD
Y
LA
S
.R . 6
BEACH RD. - S.R. 639
ST
A.
4+
M
AT
C H
L
IN
E
- S
EE
S
H
EE
T C
-1
3STA. 38+00 - M
ATC
H
LIN
E - SEE SH
EET C-15
SHADY LA. F.M., SEE SHEET C-10
24+0025+0026+0027+0028+0029+0031+0032+0033+00 30+00
ST
A.
8+
M
AT
C H
L
IN
E
- S
EE
S
H
EE
T C
-1
PROFILE - BEACH RD. - STA. 24+00 TO 38+00
34+0035+0036+0037+0038+00
ST
A.
4+
M
AT
C H
L
IN
E
- S
EE
S
H
EE
T C
-1
P:\8271 - White Stone\8271-01-005 (ENG) - WW Phase 2 Design Phase\Engineering\Engineering Plans\8271-01-005-PNP.dwg
BE
AC
H
RD
S
TA
. 2
4+
T O
8+
GRAPHIC SCALE
( IN FEET )
1 inch = ft.50
NOTES:
1. SHEETS C-5 THROUGH C-19 REFER TO ALIGNMENT FOR THE MAIN SYSTEM
FORCEMAINS. REFER TO SHEETS C-20 THROUGH C-32 FOR GRINDER PUMPS,
LATERALS AND MULTI-HOUSE COLLECTORS (MHC).
2. SERVICE TEES SHOWN IN PROFILE FOR MHC'S AND FORCEMAIN. WYES FOR
SERVICE LATERALS ARE SHOWN IN PLAN ONLY.
3. THERE SHALL BE NO OPEN CUTTING OF VDOT PAVEMENT ALONG RAPPAHANNOCK
DR., SHADY LA., OR BEACH RD. ALL FORCEMAINS, LATERALS AND MHC'S SHALL BE
DIRECTIONALLY DRILLED OR INSTALLED IN ENCASEMENT PIPE (AS NOTED) UNDER
PAVEMENT ON THOSE ROADS.
4. REFER TO SHEET C-35 FOR FLUSHING CONNECTION AND TERMINAL FLUSHING
DETAILS.
5. CASING PIPE SHALL EXTEND BEHIND DITCH WHEN CROSSING ROADWAY.
6. A MINIMUM OF 10' MUST BE MAINTAINED BETWEEN PRIVATE WELLS AND
FORCEMAINS.
7. EXISTING WATER LINES SHOWN ON THE PLANS ARE BASED UPON SCHEMATIC
RECORDS AND MAY NOT REFLECT THEIR ACTUAL LOCATION. CONTRACTOR SHALL
MAINTAIN 10-FOOT MINIMUM HORIZONTAL AND 18-INCH VERTICAL SEPARATIONS
BETWEEN EXISTING WATER LINES AND PROPOSED FORCE MAINS.
8. CONTRACTOR SHALL ENSURE LINES ARE LOCATED LONGITUDINALLY AT THE BACK
STA 38+49.85
END 800'R CURVE
N=3,763,363.89 E=12,093,277.18
STA 43+61.91
3" 45° BEND
N=3,762,871.37 E=12,093,137.04
STA 43+66.15
3" 45° BEND
N=3,762,867.67 E=12,093,139.11
STA 43+81.93
= STA 10+00 PLEASANT BANKS DR.
3"x2 TEE 3"x2" REDUCER (SW)
3" GATE VALVE
(2) 2" GATE VALVES
N=3,762,852.50…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .