This is a Scope of Work and technical specification document for Central Connecticut State University (CCSU) Project No. 23-151, the Copernicus Hall 5th Floor Door Replacement Project, located in New Britain, Connecticut. The project involves the removal and replacement of existing doors and hardware on the fifth floor of Copernicus Hall, with new doors predominantly consisting of solid core prefinished wood doors and some hollow metal doors. The contractor must submit a detailed door replacement schedule prior to work commencement, ensuring each room is secured at the end of each workday. Onsite work cannot occur during active class sessions; work may be scheduled during academic breaks (with the first targeted break being Winter Break from December 14, 2026, to January 18, 2027, or Spring Break from March 15–21, 2027) or during off-hours from 10:00 PM to 6:00 AM during active semesters. All keying and programming of Persona Locksets must be performed by the CCSU Locksmith at 40 Wells Street, New Britain, Connecticut, with a minimum of two weeks required for this process. The contractor must handle asbestos-containing material (ACM) doors by removing the door panel with hinges intact, wrapping it in plastic, and placing it in a designated container for proper disposal by others, while disposing of all non-ACM doors themselves.
The specifications detail requirements for hollow metal doors and frames (ANSI/SDI A250.8 standards), flush wood doors (AWI/AWMAC/WI standards), door hardware (ANSI/BHMA A156 Series certifications), and painting systems (Sherwin Williams products or equivalent). Door hardware sets are specified for five categories: classrooms/labs, offices, mechanical closets, all restrooms, and single-user restrooms, with hardware sourced from manufacturers including McKinney, Arrow Lock, Sargent, Rockwood, and Norton Door Controls. The document includes manufacturer-specific requirements and acceptable substitution procedures. CCSU will provide a room for staging and storage of construction materials, and the contractor must coordinate with the CCSU Locksmith for lockset delivery and pickup. Painting is specified as Paint System No. 1 for interior shop-primed ferrous metal surfaces using Sherwin Williams Pro Industrial products. No specific contract pricing, award date, or performance period is stated in this technical specification document; these details would be contained in separate bidding documents or contract agreements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CCSU Project # 23-151: Copernicus Hall 5th Floor Door Replacement Project
Scope of Work:
The scope of the work of this project is to remove and replace existing doors and hardware as indicated on the door schedule. The contractor will also be responsible for preparing and painting existing associated door frames as well as new hollow metal doors. The new doors are predominately solid core prefinished wood doors. A few are hollow metal doors. New hardware is specified. The contractor will be responsible for providing and installing all new hardware. All doors are to be factory prepped for new hardware. Most of the existing doors have tested positive for ACM. For ACM doors, this contractor is to remove the door panel with hinges intact, wrap the door panel in plastic, and load it into a container (location of container to be in close proximity to Copernicus Hall) where it will be properly disposed of by others. Disposal of all non-ACM containing doors is by this contractor.
Phasing of Work:
All rooms on the 5th Floor of the building are occupied. Prior to the start of the door replacement project, the contractor must submit a detailed door replacement schedule. The contractor must schedule their work so that each room is secured at the end of the workday.
All keying and programming of Persona Locksets is to be done by the CCSU Locksmith. The Contractor is to deliver all locksets to the CCSU Locksmith located at 40 Wells St, New Britain, CT.
The locksmith will key and program each lockset and label it for the appropriate the door opening.
The Contractor will be responsible for pick up and delivery of locksets to the jobsite. It is imperative that the contractor provide adequate time (minimum of 2 weeks) for the keying and programming of locksets.
Additional Information:
The onsite work cannot occur when classes are in session. Work can be scheduled during normal business hours if scheduled during academic breaks. Lead time dependent, the first academic break is Winter Break which runs from December 14th 2026 – January 18th 2027. In anticipation of long lead times, CCSU is currently targeting Spring Break of 2027 which is March 15th – 21st 2027 for the replacement of the doors/hardware. As an alternative, the contractor can work off hours (10:00 PM – 6:00 AM) to do onsite work during active semesters.
CCSU will provide a room in the building for staging and storage of construction materials.
SECTION 08 11 13
HOLLOW METAL DOORS AND FRAMES
SECTION 08 11 13
HOLLOW METAL DOORS AND FRAMES
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Non-fire-rated hollow metal doors and frames.
B. Hollow metal frames for wood doors.
C. Fire-rated hollow metal doors and frames.
D. Thermally insulated hollow metal doors with frames.
E. Hollow metal borrowed lites glazing frames.
F. Accessories, including glazing, louvers, and matching panels.
1.02 RELATED REQUIREMENTS
A. Related Documents: General provisions of the Contract, including General and Supplementary
Conditions and other Division 1 Specifications, apply to this Section.
B. The Contract Documents are complementary. Examine all Drawings and all other Sections of the Specifications for requirements therein affecting the intent of this Section.
1.03 REFERENCE STANDARDS
A. ADA Standards - Americans with Disabilities Act (ADA) Standards for Accessible Design; 2010.
B. ANSI/SDI A250.4 - Test Procedure and Acceptance Criteria for Physical Endurance for Steel
Doors, Frames and Frame Anchors; 2011.
C. ANSI/SDI A250.8 - Specifications for Standard Steel Doors and Frames (SDI-100); 2014.
D. ANSI/SDI A250.10 - Test Procedure and Acceptance Criteria for Prime Painted Steel Surfaces for Steel Doors and Frames; 2011.
E. ASTM A653/A653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or
Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process; 2015.
F. ASTM A1008/A1008M - Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardenable; 2016.
G. ASTM A1011/A1011M - Standard Specification for Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, and Ultra-High Strength; 2015.
H. BHMA A156.115 - American National Standard for Hardware Preparation in Steel Doors and Steel Frames; 2014.
I. ICC A117.1 - Accessible and Usable Buildings and Facilities; 2009.
J. ITS (DIR) - Directory of Listed Products; current edition.
K. NAAMM HMMA 830 - Hardware Selection for Hollow Metal Doors and Frames; 2002.
L. NAAMM HMMA 831 - Hardware Locations for Hollow Metal Doors and Frames; 2011.
M. NAAMM HMMA 840 - Guide Specifications for Installation and Storage of Hollow Metal Doors and Frames; 2007.
N. NFPA 80 - Standard for Fire Doors and Other Opening Protectives; 2016.
O. NFPA 252 - Standard Methods of Fire Tests of Door Assemblies; 2012.
COPERNICUS HALL 5TH FLOOR DOOR REPLACEMENT
PROJECT No.: 23-151
OCTOBER 15, 2026
P. UL (DIR) - Online Certifications Directory; current listings at database.ul.com.
Q. UL 10C - Standard for Positive Pressure Fire Tests of Door Assemblies; Current Edition, Including All Revisions.
COPERNICUS HALL 5TH FLOOR DOOR REPLACEMENT
PROJECT No.: 23-151
OCTOBER 15, 2026
1.04 SUBMITTALS
A. Shop Drawings: Details of each opening, showing elevations, glazing, frame profiles, and any indicated finish requirements.
B. Samples: Submit two samples of metal, 2 inch by 2 inch in size showing factory finishes, colors, and surface texture.
C. Installation Instructions: Manufacturer's published instructions, including any special installation instructions relating to this project.
D. Manufacturer's Certificate: Certification that products meet or exceed specified requirements.
1.05 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturing products specified in this section, with not less than three years documented experience.
B. Maintain at project site copies of reference standards relating to installation of products specified.
1.06 DELIVERY, STORAGE, AND HANDLING
A. Comply with NAAMM HMMA 840 or ANSI/SDI A250.8 (SDI-100) in accordance with specified requirements.
B. Protect with resilient packaging; avoid humidity build-up under coverings; prevent corrosion and adverse effects on factory applied painted finish.
PART 2 PRODUCTS
2.01 MANUFACTURERS
A. Hollow Metal Doors and Frames:
1. Ceco Door, an Assa Abloy Group company: www.assaabloydss.com.
2. Steelcraft, an Allegion brand: www.allegion.com/#sle.
3. Substitutions: See Section 01 60 00 - Product Requirements.
2.02 DESIGN CRITERIA
A. Requirements for Hollow Metal Doors and Frames:
1. Steel used for fabrication of doors and frames shall comply with one or more of the following requirements; Galvannealed steel conforming to ASTM A653/A653M, cold-rolled steel conforming to ASTM A1008/A1008M, or hot-rolled pickled and oiled (HRPO) steel conforming to ASTM A1011/A1011M, Commercial Steel (CS) Type B for each.
2. Accessibility: Comply with ICC A117.1 and ADA Standards.
3. Exterior Door Top Closures: Flush end closure channel, with top and door faces aligned.
4. Door Edge Profile: Beveled, both sides.
5. Typical Door Face Sheets: Flush.
6. Glazed Lights: Non-removable stops on non-secure side; sizes and configurations as indicated on drawings.
7. Hardware Preparations, Selections and Locations: Comply with NAAMM HMMA 830 and
NAAMM HMMA 831 or BHMA A156.115 and ANSI/SDI A250.8 (SDI-100) in accordance with specified requirements.
B. Hollow Metal Panels: Same construction, performance, and finish as doors.
C. Combined Requirements: If a particular door and frame unit is indicated to comply with more than one type of requirement, comply with the specified requirements for each type; for instance, an exterior door that is also indicated as being sound-rated must comply with the requirements specified for exterior doors and for sound-rated doors; where two requirements conflict, comply with the most stringent.
http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/
2.03 HOLLOW METAL DOORS
A. Exterior Doors: Thermally insulated.
1. Based on SDI Standards: ANSI/SDI A250.8 (SDI-100).
a. Level 1 - Standard-duty.
b. Physical Performance Level C, 250,000 cycles; in accordance with ANSI/SDI A250.4.
c. Model 1 - Full Flush.
d. Door Face Metal Thickness: 20 gage, 0.032 inch, minimum.
e. Zinc Coating: A60/ZF180 galvannealed coating; ASTM A653/A653M.
2. Core Material: Polystyrene, 1 lbs/cu ft minimum density.
3. Door Thickness: 1-3/4 inch, nominal.
4. Weatherstripping: Integral, recessed into door edge or frame.
5. Door Finish: Factory primed and field finished.
6. Door Face Metal Thickness: 16 gage, minimum
B. Interior Doors, Non-Fire Rated:
1. Door Thickness: 1-3/4 inch, nominal.
2. Door Finish: Factory primed and field finished.
3. Door Face Metal Thickness: 18 gage, minimum.
C. Fire-Rated Doors:
1. Fire Rating: As indicated on Door Schedule, tested in accordance with UL 10C and NFPA
252 ("positive pressure fire tests").
2. Provide units listed and labeled by UL (DIR) or ITS (DIR).
a. Attach fire rating label to each fire rated unit.
3. Door Thickness: 1-3/4 inch, nominal.
2.04 HOLLOW METAL FRAMES
A. Comply with standards and/or custom guidelines as indicated for corresponding door in accordance with applicable door frame requirements.
B. Frame Finish: Factory primed and field finished.
C. Exterior Door Frames: Full profile/continuously welded type.
1. Galvanizing: Components hot-dipped zinc-iron alloy-coated (galvannealed) in accordance with ASTM A653/A653M, with A40/ZF120 coating.
2. Frame Metal Thickness: 14 gage, 0.067 inch, minimum.
3. Weatherstripping: Separate, see Section 08 71 00.
D. Interior Door Frames, Non-Fire Rated: Full profile/continuously welded type.
1. Frame Metal Thickness: 16 gage, 0.053 inch, minimum.
E. Door Frames, Fire-Rated: Full profile/continuously welded type.
1. Fire Rating: Same as door, labeled.
F. Frames for Wood Doors: Comply with frame requirements in accordance with corresponding door.
G. Borrowed Lites Glazing Frames: Construction and face dimensions to match door frames, and as indicated on drawings.
2.05 ACCESSORIES
A. Louvers: Roll formed steel with overlapping frame; finish same as door components;
factory-installed.
1. In Fire-Rated Doors: UL (DIR) or ITS (DIR) listed fusible link louver, same rating as door.
B. Glazing: As specified in Section 08 80 00, factory installed.
COPERNICUS HALL 5TH FLOOR DOOR REPLACEMENT
PROJECT No.: 23-151
OCTOBER 15, 2026
http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/
C. Removable Stops: Formed sheet steel, shape as indicated on drawings, mitered or butted corners; prepared for countersink style tamper proof screws.
D. Astragals for Double Doors: Specified in Section 08 71 00.
E. Grout for Frames: Portland cement grout with maximum 4 inch slump for hand troweling;
thinner pumpable grout is prohibited.
F. Silencers: Resilient rubber, fitted into drilled hole; provide three on strike side of single door, three on center mullion of pairs, and two on head of pairs without center mullions.
G. Temporary Frame Spreaders: Provide for factory- or shop-assembled frames.
2.06 FINISHES
A. Primer: Rust-inhibiting, complying with ANSI/SDI A250.10, door manufacturer's standard.
B. Bituminous Coating: Asphalt emulsion or other high-build, water-resistant, resilient coating.
PART 3 EXECUTION
3.01 EXAMINATION
A. Verify existing conditions before starting work.
B. Verify that opening sizes and tolerances are acceptable.
C. Verify that finished walls are in plane to ensure proper door alignment.
3.02 INSTALLATION
A. Install doors and frames in accordance with manufacturer's instructions and related requirements of specified door and frame standards or custom guidelines indicated.
B. Install fire rated units in accordance with NFPA 80.
C. Coordinate frame anchor placement with wall construction.
D. Grout frames in masonry construction, using hand trowel methods; brace frames so that pressure of grout before setting will not deform frames.
E. Comply with glazing installation requirements of Section 08 80 00.
F. Coordinate installation of electrical connections to electrical hardware items.
G. Touch up damaged factory finishes.
3.03 TOLERANCES
A. Maximum Diagonal Distortion: 1/16 inch measured with straight edge, corner to corner.
3.04 ADJUSTING
A. Adjust for smooth and balanced door movement.
END OF SECTION
COPERNICUS HALL 5TH FLOOR DOOR REPLACEMENT
PROJECT No.: 23-151
OCTOBER 15, 2026
http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/ http://www.naamm.org/
SECTION 08 14 16
FLUSH WOOD DOORS
COPERNICUS HALL 5TH FLOOR DOOR REPLACEMENT
PROJECT No.: 23-151
OCTOBER 15, 2026
SECTION 08 14 16
FLUSH WOOD DOORS
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Flush wood doors; flush and flush glazed configuration; Fire-rated.
1.02 RELATED REQUIREMENTS
A. Related Documents: General provisions of the Contract, including General and Supplementary Conditions and other Division 1 Specifications, apply to this Section.
B. The Contract Documents are complementary. Examine all Drawings and all other Sections of the Specifications for requirements therein affecting the intent of this Section.
1.03 REFERENCE STANDARDS
A. AWI/AWMAC/WI (AWS) - Architectural Woodwork Standards; 2014.
B. AWMAC/WI (NAAWS) - North American Architectural Woodwork Standards, U.S. Version 3.0;
2016.
1.04 SUBMITTALS
A. Product Data: Indicate door core materials and construction; veneer species, type and characteristics. Provide manufacturer's product data for each composite wood product and laminating adhesive indicating no added urea formaldehyde in bonding agents.
B. Shop Drawings: Show doors and frames, elevations, sizes, types, swings, undercuts, beveling, blocking for hardware, factory machining, factory finishing, cutouts for glazing and other details.
1. Provide information as required by AWI/AWMAC/WI (AWS) or AWMAC/WI (NAAWS).
C. Specimen warranty.
D. Samples: Submit two samples of door construction, 12 by 12 inch in size cut from top corner of door.
E. Samples: Submit two samples of door veneer, 12 by 12 inch in size illustrating wood grain, stain color, and sheen.
F. Manufacturer's Installation Instructions: Indicate special installation instructions.
G. Warranty, executed in Owner's name.
1.05 QUALITY ASSURANCE
A. Maintain one copy of the specified door quality standard on site for review during installation and finishing.
B. Manufacturer Qualifications: Company specializing in manufacturing the products specified in this section, with not less than five years of documented experience.
1.06 DELIVERY, STORAGE, AND HANDLING
A. Package, deliver and store doors in accordance with specified quality standard.
B. Accept doors on site in manufacturer's packaging. Inspect for damage.
C. Protect doors with resilient packaging sealed with heat shrunk plastic. Do not store in damp or wet areas; or in areas where sunlight might bleach veneer. Seal top and bottom edges with tinted sealer if stored more than one week. Break seal on site to permit ventilation.
1.07 WARRANTY
A. See Section 01 78 30 - Warranties and Bonds, for additional warranty requirements.
B. Interior Doors: Provide manufacturer's warranty for the life of the installation.
C. Include coverage for delamination of veneer, warping beyond specified installation tolerances, defective materials, and telegraphing core construction.
PART 2 PRODUCTS
2.01 MANUFACTURERS
A. Wood Veneer Faced Doors:
1. Forte Opening Solutions; Aspiro Series: www.forteopenings.com
2. VT Industries; Heritage Collection: www.vtindustries.com.
3. Manhattan Doors; Veneer Series: www.ManhattanDoorcom.
4. Substitutions: See Section 01 60 00 - Product Requirements.
2.02 DOORS AND PANELS
A. Doors: Refer to drawings for locations and additional requirements.
1. Quality Standard: Custom Grade, Heavy Duty performance, in accordance with AWI/ AWMAC/WI (AWS) or AWMAC/WI (NAAWS), unless noted otherwise.
2. Wood Veneer Faced Doors: 5-ply unless otherwise indicated.
B. Interior Doors: 1-3/4 inches thick unless otherwise indicated; flush construction.
1. Provide solid core doors at each location.
2. Wood veneer facing for factory transparent finish as indicated on drawings.
3. All doors located at single occupant toilet rooms shall be provided with a 3/4" undercut from finish floor surface.
2.03 DOOR AND PANEL CORES
A. Non-rated Solid Core and 45 Minute Rated Doors: Type particleboard core (PC), plies and faces as indicated.
2.04 DOOR FACINGS
A. Veneer Facing for Transparent Finish: Oak, veneer grade in accordance with quality standard indicated, plain sliced (flat cut), with book match between leaves of veneer, running match of spliced veneer leaves assembled on door or panel face.
2.05 DOOR CONSTRUCTION
A. Fabricate doors in accordance with door quality standard specified.
B. Cores Constructed with stiles and rails:
1. Provide minimum 5" x 12" solid blocks at lock edge for hardware reinforcement.
2. Provide solid blocking for other throughbolted hardware.
C. Where supplementary protective edge trim is required, install trim after veneer facing has been applied full-width.
D. Factory machine doors for hardware other than surface-mounted hardware, in accordance with hardware requirements and dimensions.
E. Factory fit doors for frame opening dimensions identified on shop drawings, with edge clearances in accordance with specified quality standard.
1. Exception: Doors to be field finished.
F. Provide edge clearances in accordance with the quality standard specified.
G. Provide factory installed narrow stile lite where indicated. Lite to be transparent fire rated glass with flush wood stops.
COPERNICUS HALL 5TH FLOOR DOOR REPLACEMENT
PROJECT No.: 23-151
OCTOBER 15, 2026
PART 3 EXECUTION
3.01 EXAMINATION
A. Verify existing conditions before starting work.
B. Verify that opening sizes and tolerances are acceptable.
C. Do not install doors in frame openings that are not plumb or are out-of-tolerance for size or alignment.
3.02 INSTALLATION
A. Install doors in accordance with manufacturer's instructions and specified quality standard.
B. Factory-Finished Doors: Do not field cut or trim; if fit or clearance is not correct, replace door.
C. Use machine tools to cut or drill for hardware.
D. Coordinate installation of doors with installation of frames and hardware.
E. Coordinate installation of glazing.
F. Install door louvers plumb and level.
3.03 TOLERANCES
A. Conform to specified quality standard for fit and clearance tolerances.
B. Conform to specified quality standard for telegraphing, warp, and squareness.
3.04 ADJUSTING
A. Adjust doors for smooth and balanced door movement.
B. Adjust closers for full closure.
END OF SECTION
COPERNICUS HALL 5TH FLOOR DOOR REPLACEMENT
PROJECT No.: 23-151
OCTOBER 15, 2026
2.06 FACTORY FINISHING - WOOD VENEER DOORS
A. Finish work in accordance with AWI/AWMAC/WI (AWS) or AWMAC/WI (NAAWS), Section 5 -
Finishing for grade specified and as follows:
1. Transparent:
a. System - 11, Polyurethane, Catalyzed.
b. Stain: As selected by Architect.
c. Sheen: Satin.
B. Seal door top edge with color sealer to match door facing.
SECTION 087100
DOOR HARDWARE
COPERNICUS HALL 5th FLOOR DOOR REPLACEMENT
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section.
1.2 SUMMARY
A. This Section includes commercial door hardware for the following:
1. Swinging doors.
B. Door hardware includes, but is not necessarily limited to, the following:
1. Mechanical door hardware.
2. Electromechanical door hardware.
C. Related Sections:
1. Division 08 Section “Hollow Metal Doors and Frames”.
2. Division 08 Section “Flush Wood Doors”.
D. Codes and References: Comply with the version year adopted by the Authority Having Jurisdiction.
1. ANSI A117.1 - Accessible and Usable Buildings and Facilities.
2. ICC/IBC - International Building Code.
3. NFPA 80 - Fire Doors and Windows.
4. NFPA 101 - Life Safety Code.
5. NFPA 105 - Installation of Smoke Door Assemblies.
6. State Building Codes, Local Amendments.
E. Standards: All hardware specified herein shall comply with the following industry standards:
1. ANSI/BHMA Certified Product Standards - A156 Series
2. UL10C – Positive Pressure Fire Tests of Door Assemblies
1.3 SUBMITTALS
A. Product Data: Manufacturer's product data sheets including installation details, material descriptions, dimensions of individual components and profiles, operational descriptions and finishes.
B. Door Hardware Schedule: Prepared by or under the supervision of supplier, detailing fabrication and assembly of door hardware, as well as procedures and diagrams. Coordinate the final Door Hardware Schedule with doors, frames, and related work to ensure proper size, thickness, hand, function, and finish of door hardware.
1. Format: Comply with scheduling sequence and vertical format in DHI's "Sequence and Format for the Hardware Schedule."
2. Organization: Organize the Door Hardware Schedule into door hardware sets indicating complete designations of every item required for each door or opening. Organize door hardware sets in same order as in the Door Hardware Sets at the end of Part 3. Submittals that do not follow the same format and order as the Door Hardware Sets will be rejected and subject to resubmission.
3. Content: Include the following information:
a. Type, style, function, size, label, hand, and finish of each door hardware item.
b. Manufacturer of each item.
c. Fastenings and other pertinent information.
d. Location of door hardware set, cross-referenced to Drawings, both on floor plans and in door and frame schedule.
e. Explanation of abbreviations, symbols, and codes contained in schedule.
f. Mounting locations for door hardware.
g. Door and frame sizes and materials.
4. Submittal Sequence: Submit the final Door Hardware Schedule at earliest possible date, particularly where approval of the Door Hardware Schedule must precede fabrication of other work that is critical in the Project construction schedule. Include Product Data, Samples, Shop Drawings of other work affected by door hardware, and other information essential to the coordinated review of the Door Hardware Schedule.
C. Shop Drawings: Details of electrified access control hardware indicating the following:
1. Wiring Diagrams: Upon receipt of approved schedules, submit detailed system wiring diagrams for power, signaling, monitoring, communication, and control of the access control system electrified hardware. Differentiate between manufacturer-installed and field-installed wiring. Include the following:
a. Elevation diagram of each unique access-controlled opening showing location and interconnection of major system components with respect to their placement in the respective door openings.
b. Complete (risers, point-to-point) access control system block wiring diagrams.
D. Keying Schedule: By owner.
E. Operating and Maintenance Manuals: Provide manufacturers operating and maintenance manuals for each item comprising the complete door hardware installation in quantity as required in Division 01, Closeout Submittals. The manual is to include the name, address, and contact information of the manufacturers providing the hardware and their nearest service representatives. The final copies delivered after completion of the installation test are to include "as built" modifications made during installation, checkout, and acceptance.
F. Warranties and Maintenance: Special warranties and maintenance agreements specified in this Section.
1.4 QUALITY ASSURANCE
A. Manufacturers Qualifications: Engage qualified manufacturers with a minimum of 5 years of documented experience in producing hardware and equipment like that indicated for this Project and that have a proven record of successful in-service performance.
B. Installer Qualifications: Installers, trained by the primary product manufacturers, with a minimum of 3 years of documented experience installing both standard and electrified hardware similar in material, design, and extent to that indicated for this Project and whose work has resulted in construction with a record of successful in-service performance.
C. Door Hardware Supplier Qualifications: Experienced commercial door hardware distributors with a minimum of 5 years of documented experience supplying both mechanical and electromechanical hardware installations comparable in material, design, and extent to that indicated for this Project. Supplier recognized as a factory direct distributor in good standing by the manufacturers of the primary materials with a warehousing facility in Project's vicinity. Supplier to have on staff a certified Architectural Hardware Consultant (AHC) available during the Work to consult with Contractor, Architect, and Owner concerning both standard and electromechanical door hardware and keying.
1. Scheduling Responsibility: Preparation of door hardware.
D. Source Limitations: Obtain each type and variety of Door Hardware specified in this Section from a single source, qualified supplier unless otherwise indicated.
1. Electrified modifications or enhancements made to a source manufacturer's product line by a secondary or third-party source will not be accepted.
2. Provide electromechanical door hardware from the same manufacturer as mechanical door hardware, unless otherwise indicated.
E. Regulatory Requirements: Comply with NFPA 70, NFPA 80, NFPA 101 and ANSI A117.1 requirements and guidelines as directed in the model building code including, but not limited to, the following:
1. NFPA 70 "National Electrical Code", including electrical components, devices, and accessories listed and labeled as defined in Article 100 by a testing agency acceptable to authorities having jurisdiction, and marked for intended use.
2. Where indicated to comply with accessibility requirements, comply with Americans with Disabilities Act (ADA), "Accessibility Guidelines for Buildings and Facilities (ADAAG)," ANSI A117.1 as follows:
a. Handles, Pulls, Latches, Locks, and other Operating Devices: Shape that is easy to grasp with one hand and does not require tight grasping, tight pinching, or twisting of the wrist.
b. Door Closers: Comply with the following maximum opening-force requirements indicated:
1) Interior Hinged Doors: 5 lbf applied perpendicular to door.
2) Fire Doors: Minimum opening force allowable by authorities having jurisdiction.
c. Thresholds: Not more than 1/2 inch high. Bevel raised thresholds with a slope of not more than 1:2.
3. NFPA 101: Comply with the following for means of egress doors:
a. Latches, Locks, and Exit Devices: Not more than 15 lbf to release the latch. Locks shall not require the use of a key, tool, or special knowledge for operation.
b. Thresholds: Not more than 1/2 inch high.
F. Each unit to bear third party permanent label demonstrating compliance with the referenced standards.
G. Pre-Submittal Conference: Conduct coordination conference in compliance with requirements in Division 01 Section "Project Meetings" with attendance by representatives of Supplier(s), Installer(s), and Contractor(s) to review proper methods and the procedures for receiving, handling, and installing door hardware.
1. Prior to installation of door hardware, conduct a project specific training meeting to instruct the installing contractors' personnel on the proper installation and adjustment of their respective products. Product training to be attended by installers of door hardware (including electromechanical hardware) for aluminum, hollow metal and wood doors.
Training will include the use of installation manuals, hardware schedules, templates and physical product samples as required.
2. Inspect and discuss electrical roughing-in, power supply connections, and other preparatory work performed by other trades.
3. Review sequence of operation narratives for each unique access-controlled opening.
4. Review and finalize construction schedule and verify availability of materials.
5. Review the required inspecting, testing, commissioning, and demonstration procedures
H. At completion of installation, provide written documentation that components were applied to manufacturer's instructions and recommendations and according to approved schedule.
1.5 DELIVERY, STORAGE, AND HANDLING
A. Inventory door hardware on receipt and provide secure lock-up and shelving for door hardware delivered to Project site. Do not store, if any, electronic access control hardware, software or accessories at Project site without prior authorization.
B. Tag each item or package separately with identification related to the final Door Hardware Schedule and include basic installation instructions with each item or package.
C. Deliver, as applicable, permanent keys, cylinders, cores, access control credentials, software and related accessories directly to Owner via registered mail or overnight package service.
Instructions for delivery to the Owner shall be established at the "Keying Conference".
1.6 COORDINATION
A. Templates: Obtain and distribute to the parties’ involved templates for doors, frames, and other work specified to be factory prepared for installing standard and electrified hardware. Check Shop Drawings of other work to confirm that adequate provisions are made for locating and installing hardware to comply with indicated requirements.
B. Door Hardware and Electrical Connections: Coordinate the layout and installation of scheduled electrified door hardware and related access control equipment with required connections to source power junction boxes, low voltage power supplies, detection and monitoring hardware, and fire and detection alarm systems.
C. Door and Frame Preparation: Related Division 08 Sections (Wood) doors and corresponding frames are to be prepared, reinforced and pre-wired (if applicable) to receive the installation of the specified electrified, monitoring, signaling and access control system hardware without additional in-field modifications.
1.7 WARRANTY
A. General Warranty: Reference Division 01, General Requirements. Special warranties specified in this Article shall not deprive Owner of other rights Owner may have under other provisions of the Contract Documents and shall be in addition to, and run concurrent with, other warranties made by Contractor under requirements of the Contract Documents.
B. Warranty Period: Written warranty, executed by manufacturer(s), agreeing to repair or replace components of standard and electrified door hardware that fails in materials or workmanship within specified warranty period after final acceptance by the Owner. Failures include, but are not limited to, the following:
1. Structural failures including excessive deflection, cracking, or breakage.
2. Faulty operation of the hardware.
3. Deterioration of metals, metal finishes, and other materials beyond normal weathering.
4. Electrical component defects and failures within the systems operation.
C. Standard Warranty Period: One year from date of Substantial Completion, unless otherwise indicated.
D. Special Warranty Periods:
1. Twenty-five years for manual surface door closers.
2. Two years for electromechanical door hardware.
1.8 MAINTENANCE SERVICE
A. Maintenance Tools and Instructions: Furnish a complete set of specialized tools and maintenance instructions as needed for Owner's continued adjustment, maintenance, and removal and replacement of door hardware.
B. Continuing Service: Beginning at Substantial Completion, and running concurrent with the specified warranty period, provide continuous (6) months full maintenance including repair and replacement of worn or defective components, lubrication, cleaning, and adjusting as required for proper door opening operation. Provide parts and supplies as used in the manufacture and installation of original products.
PART 2 - PRODUCTS
2.1 SCHEDULED DOOR HARDWARE
A. General: Provide door hardware for each door to comply with requirements in Door Hardware Sets and each referenced section that products are to be supplied under.
1. Designations: Requirements for quantity, item, size, finish or color, grade, function, and other distinctive qualities of each type of door hardware are indicated in the Door Hardware Sets at the end of Part 3. Products are identified by using door hardware designations, as follows:
a. Named Manufacturer's Products: Product designation and manufacturer are listed for each door hardware type required for the purpose of establishing requirements.
Manufacturers' names are abbreviated in the Door Hardware Schedule.
B. Substitutions: Requests for substitution and product approval for inclusive mechanical and electromechanical door hardware in compliance with the specifications must be submitted in writing and in accordance with the procedures and time frames outlined in Division 01, Substitution Procedures. Approval of requests is at the discretion of the architect, owner, and their designated consultants.
2.2 HANGING DEVICES
A. Hinges: ANSI/BHMA A156.1 certified butt hinges with number of hinge knuckles as specified in the Door Hardware Sets.
1. Acceptable Manufacturers:
a. Hager Companies (HA).
b. McKinney Products (MK).
c. Stanley Hardware (ST).
2.3 DOOR OPERATING TRIM
A. Flush Bolts and Surface Bolts: ANSI/BHMA A156.3 and A156.16, Grade 1, certified automatic, self-latching, and manual flush bolts and surface bolts. Manual flush bolts to be furnished with top rod of sufficient length to allow bolt location approximately six feet from the floor. Furnish dust proof strikes for bottom bolts. Surface bolts to be minimum 8” in length and U.L. listed for labeled fire doors and U.L. listed for windstorm components where applicable. Provide related accessories (mounting brackets, strikes, coordinators, etc.) as required for appropriate installation and operation.
1. Acceptable Manufacturers:
a. Burns Manufacturing (BU).
b. Rockwood Manufacturing (RO).
c. Trimco (TC).
B. Door Push Plates and Pulls: ANS/BHMA A156.6 certified door pushes and pulls of type and design specified below or in the Hardware Sets. Coordinate and provide proper width and height as required where conflicting hardware dictates.
1. Push/Pull Plates: Minimum .050 inch thick, size as indicated in hardware sets, with square corners and beveled edges, secured with exposed screws unless otherwise indicated.
2. Door Pull and Push Bar Design: Size, shape, and material as indicated in the hardware sets. Minimum clearance of 2 1/2-inches from face of door unless otherwise indicated.
3. Fasteners: Provide manufacturer's designated fastener type as indicated in Hardware Sets.
a. Acceptable Manufacturers:
1) Burns Manufacturing (BU).
2) Rockwood Manufacturing (RO).
3) Trimco (TC).
2.4 CYLINDERS AND KEYING
CYLINDERS WILL BE PROVIDED BY THE OWNER
2.5 MECHANICAL LOCKS AND LATCHING DEVICES
A. Cylindrical Locksets, Grade 1 (Heavy Duty): ANSI/BHMA A156.2, Series 4000, Grade 1 certified cylindrical (bored) locksets furnished in the functions as specified in the Hardware Sets. Lock chassis fabricated of heavy gauge steel, zinc dichromate plated, with through-bolted application.
Furnish with solid cast levers, standard 2 3/4” backset, and 1/2" (3/4" at rated paired openings) throw brass or stainless steel latchbolt. Locks are to be non-handed and fully field reversible.
1. Acceptable Manufacturers:
a. Arrow (AW) – QL Series. (No Substitutions – Facility Standard)
2.6 CONVENTIONAL EXIT DEVICES
A. General Requirements: All exit devices specified herein shall meet or exceed the following criteria:
1. At doors not requiring a fire rating, provide devices complying with NFPA 101 and listed and labeled for "Panic Hardware" according to UL305. Provide proper fasteners as required by manufacturer including sex nuts and bolts at openings specified in the Hardware Sets.
2. Where exit devices are required on fire rated doors, provide devices complying with NFPA 80 and with UL labeling indicating "Fire Exit Hardware". Provide devices with the proper fasteners for installation as tested and listed by UL. Consult manufacturer’s catalog and template book for specific requirements.
3. Except on fire rated doors, provide exit devices with hex key dogging device to hold the pushbar and latch in a retracted position. Provide optional keyed cylinder dogging on devices where specified in Hardware Sets.
4. Flush End Caps: Provide heavy weight impact resistant flush end caps made of architectural metal in the same finish as the devices as in the Hardware Sets. Plastic end caps will not be acceptable.
5. Vertical Rod Exit Devices: Provide and install interior surface and concealed vertical rod exit devices as Less Bottom Rod (LBR) unless otherwise indicated.
6. Rail Sizing: Provide exit device rails factory sized for proper door width application.
B. Conventional Push Rail Exit Devices (Heavy Duty): ANSI/BHMA A156.3, Grade 1 certified panic and fire exit hardware devices furnished in the functions specified in the Hardware Sets. Mounting rails to be formed from smooth stainless steel, brass or bronze architectural materials no less than 0.072" thick, with push rails a minimum of 0.062" thickness. Painted or aluminum metal rails are not acceptable. Exit device latch to be investment cast stainless steel, pullman type, with deadlock feature.
1. Acceptable Manufacturers:
a. Sargent Manufacturing (SA) - 80 Series.
b. Arrow (AW) – S1250 Series
c. Von Duprin (VD) - 98 XP Series.
2.7 LOCK AND LATCH STRIKES
A. Strikes: Provide manufacturer's standard strike with strike box for each latch or lock bolt, with curved lip extended to protect frame, finished to match door hardware set, unless otherwise indicated.
B. Standards: Comply with the following:
1. Strikes for Bored Locks and Latches: BHMA A156.2.
2. Dustproof Strikes: BHMA A156.16.
2.8 DOOR CLOSERS
A. All door closers specified herein shall meet or exceed the following criteria:
1. General: Door closers to be from one manufacturer, matching in design and style, with the same type door preparations and templates regardless of application or spring size.
Closers to be non-handed with full sized covers including installation and adjusting information on inside of cover.
2. Standards: Closers to comply with UL-10C and UBC 7-2 for Positive Pressure Fire Test and be U.L. listed for use of fire rated doors.
3. Cycle Testing: Provide closers which have surpassed 10 million cycles in a test witnessed and verified by UL.
4. Size of Units: Comply with manufacturer's written recommendations for sizing of door closers depending on size of door, exposure to weather, and anticipated frequency of use.
Where closers are indicated for doors required to be accessible to the physically handicapped, provide units complying with ANSI ICC/A117.1.
5. Closer Arms: Provide heavy duty, forged steel closer arms unless otherwise indicated in Hardware Sets.
a. Where closers are indicated to have mechanical dead-stop, provide heavy duty arms and brackets with an integral positive stop.
b. Where closers are indicated to have mechanical hold open, provide heavy duty units with an additional built-in mechanical holder assembly designed to hold open against normal wind and traffic conditions. Holder to be manually selectable to on-off position.
c. Where closers are indicated to have a cushion-type stop, provide heavy duty arms and brackets with spring stop mechanism to cushion door when opened to maximum degree.
d. Closers shall not be installed on exterior or corridor side of doors; where possible install closers on door for optimum aesthetics. Provide drop plates or other accessories as required for proper mounting.
6. Closer Accessories: Provide door closer accessories including custom templates, special mounting brackets, spacers and drop plates, and through-bolt or security type fasteners as specified in the door Hardware Sets.
B. Door Closers, Surface Mounted (Commercial Duty): ANSI/BHMA 156.4, Grade 1 certified surface mounted, institutional grade door closers with complete spring power adjustment, sizes 1 thru 6;
and fully operational adjustable according to door size, frequency of use, and opening force.
Closers to be rack and pinion type, one piece cast iron or aluminum alloy body construction, with adjustable backcheck, closing sweep, and latch speed control valves. Provide non-handed units standard.
1. Acceptable Manufacturers:
a. Arrow (AW) – 5016 Series.
b. Norton Door Controls (NO) - 8500 Series.
c. Sargent Manufacturing (SA) - 1431 Series.
2.9 ARCHITECTURAL TRIM
A. Door Protective Trim
1. General: Door protective trim units to be of type and design as specified below or in the Hardware Sets.
2. Size: Fabricate protection plates (kick, armor, or mop) not more than 2" less than door width (LDW) on stop side of single doors and 1” LDW on stop side of pairs of doors, and not more than 1" less than door width on pull side. Coordinate and provide proper width and height as required where conflicting hardware dictates. Height to be as specified in the Hardware Sets.
3. Metal Protection Plates: ANSI/BHMA A156.6 certified metal protection plates (kick, armor, or mop), beveled on four edges (B4E), fabricated from the following.
a. Stainless Steel: 050-inch thick, with countersunk screw holes (CSK).
4. Fasteners: Provide manufacturer's designated fastener type as specified in the Hardware Sets.
5. Acceptable Manufacturers:
a. Burns Manufaxcturing (BU).
b. Rockwood Manufacturing (RO).
c. Trimco (TC).
2.10 DOORSTOPS AND HOLDERS
A. Door Stops and Bumpers: ANSI/BHMA A156.16, Grade 1 certified door stops and wall bumpers.
Provide wall bumpers, either convex or concave types with anchorage as indicated, unless floor or other types of doorstops are specified in Hardware Sets. Do not mount floor stops where they will impede traffic. Where floor or wall bumpers are not appropriate, provide overhead type stops and holders.
1. Acceptable Manufacturers:
a. Burns Manufacturing (BU).
b. Rockwood Manufacturing (RO).
c. Trimco (TC).
2.11 ARCHITECTURAL SEALS
A. General: Thresholds, weatherstripping, and gasket seals to be of type and design as specified below or in the Hardware Sets. Provide continuous weatherstrip gasketing on exterior doors and provide smoke, light, or sound gasketing on interior doors where indicated. At exterior applications provide non-corrosive fasteners and elsewhere where indicated.
B. Replaceable Seal Strips: Provide only those units where resilient or flexible seal strips are easily replaceable and readily available from stocks maintained by manufacturer.
C. Acceptable Manufacturers:
1. Pemko Manufacturing (PE).
2. Reese Enterprises, Inc. (RS).
3. Zero International (ZE).
2.12 FABRICATION
A. Fasteners: Provide door hardware manufactured to comply with published templates generally prepared for machine, wood, and sheet metal screws. Provide screws according to manufacturers recognized installation standards for application intended.
2.13 FINISHES
A. Standard: Designations used in the Hardware Sets and elsewhere indicate hardware finishes complying with ANSI/BHMA A156.18, including coordination with traditional U.S. finishes indicated by certain manufacturers for their products.
B. Provide quality of finish, including thickness of plating or coating (if any), composition, hardness, and other qualities complying with manufacturer's standards, but in no case less than specified by referenced standards for the applicable units of hardware.
C. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine scheduled openings, with Installer present, for compliance with requirements for installation tolerances, labeled fire door assembly construction, wall and floor construction, and other conditions affecting performance.
B. Notify Project Coordinator of any discrepancies or conflicts between the door schedule, door types, drawings and scheduled hardware. Proceed only after such discrepancies or conflicts have been resolved in writing.
3.2 PREPARATION
A. Wood Doors: Comply with ANSI/DHI A115-W series.
3.3 INSTALLATION
A. Install each item of mechanical and electromechanical hardware and access control equipment to comply with manufacturer's written instructions and according to specifications.
1. Installers are to be trained and certified by the manufacturer on the proper installation and adjustment of fire, life safety, and security products including hanging devices; locking devices; closing devices; and seals.
B. Mounting Heights: Mount door hardware units at heights indicated in following applicable publications, unless specifically indicated or required to comply with governing regulations:
1. Standard Steel Doors and Frames: DHI's "Recommended Locations for Architectural Hardware for Standard Steel Doors and Frames."
2. Wood Doors: DHI WDHS.3, "Recommended Locations for Architectural Hardware for Wood Flush Doors."
3. Where indicated to comply with accessibility requirements, comply with ANSI A117.1 "Accessibility Guidelines for Buildings and Facilities."
4. Provide blocking in drywall partitions where wall stops or other wall mounted hardware is located.
C. Retrofitting: Install door hardware to comply with manufacturer's published templates and written instructions. Where cutting and fitting are required to install door hardware onto or into surfaces that are later to be painted or finished in another way, coordinate removal, storage, and reinstallation of surface protective trim units with finishing work specified in Division 9 Sections.
Do not install surface-mounted items until finishes have been completed on substrates involved.
D. Thresholds: Set thresholds for exterior and acoustical doors in full bed of sealant complying with requirements specified in Division 7 Section "Joint Sealants."
E. Storage: Provide a secure lock-up for hardware delivered to the project but not yet installed.
Control the handling and installation of hardware items so that the completion of the work will not be delayed by hardware losses before and after installation.
3.4 FIELD QUALITY CONTROL
A. Field Inspection: Supplier will perform a final inspection of installed door hardware and state in report whether work complies with or deviates from requirements, including whether door hardware is properly installed, operating and adjusted.
3.5 ADJUSTING
A. Initial Adjustment: Adjust and check each operating item of door hardware and each door to ensure proper operation or function of every unit. Replace units that cannot be adjusted to operate as intended. Adjust door control devices to compensate for final operation of heating and ventilating equipment and to comply with referenced accessibility requirements.
3.6 CLEANING AND PROTECTION
A. Protect all hardware stored on the construction site in a covered and dry place. Protect exposed hardware installed on doors during the construction phase. Install all hardware at the latest possible time frame.
B. Clean adjacent surfaces soiled by door hardware installation.
C. Clean operating items as necessary to restore proper finish. and provide final protection and maintain conditions that ensure door hardware is without damage or deterioration at time of owner occupancy.
3.7 DEMONSTRATION
A. Instruct Owner's maintenance personnel to adjust, operate, and maintain mechanical and electromechanical door hardware.
3.8 DOOR HARDWARE SCHEDULE
A. The hardware sets represent the design intent and direction of the owner and Project Coordinator.
They are a guideline only and should not be considered a detailed hardware schedule.
Discrepancies, conflicting hardware and missing items should be brought to the attention of the Project Coordinator with corrections made prior to the bidding process. Omitted items not included in a hardware set should be scheduled with the appropriate additional hardware required for proper application and functionality.
Manufacturers Abbreviations:
1. MK - McKinney
2. AW - Arrow Lock
3. SA - Sargent
4. AA - ASSA High Security Locks
5. HS - HES
6. RO - Rockwood
7. NO - Norton
8. PE - Pemko
Set: 1.0 (all classroom/labs)
3 Hinge (heavy weight) T4A3786 4-1/2" x 4-1/2" US26D MK 087100 1 Access Control Cyl Lock IN120-10XG77-BIKPS-MB-OA-LL-26D US26D SA 087100 1 Key In Lever Cylinder E65673 (Sargent) 626 AA 087100 (keyed by Owner) 1 Wall Stop 401/404 US26D RO 087100 3 Silencer RO 087100 1 Kick Plate K1050 8" 4BE CSK US32D RO 087100
Set: 2.0 (all offices)
1 Access Control Cyl Lock IN120-10XG77-BIKPS-MB-OA-LL-26D US26D SA 087100 1 Key In Lever Cylinder E65673 (Sargent) 626 AA 087100 (keyed by Owner)…